1 Installation and Operation of AST Equipment Presenter: Steve Allwein Northeast Regional Sales Manager Morrison Bros. Co.
2 HISTORY Morrison Bros. Co. Then Founded in 1855 Located in Dubuque, Iowa Originally a boiler manufacturer Then began manufacturing equipment for the oil industry Founder of Morrison Bros. Co.
3 HISTORY Morrison Bros. Co. Now Leader in AST products Produce more than 1,200 different products Include equipment for ASTs, USTs & service stations, environmental applications and tank trucks. Employ approximately 130 people in Dubuque & Maquoketa, Iowa locations. Morrison Bros. Co. Corporate Headquarters
4 TANKS Shop-Fabricated Tanks Shop-fabricated tanks are small enough to be produced in a tank manufacturing plant and delivered to the site. Atmospheric Pressure Tanks: 0-1 PSI operating pressure. Vertical Tank: The shell height shall not be more than 50 feet and shall not exceed 60,000 gallons. July 19, 2013 (UL 142). Horizontal Tank: The length of the shall not be greater than 6 times its diameter. Tank diameters exceeding 144 inches shall not exceed 72 feet in length. July 19, 2013 (UL 142).
5 TANKS Vertical Tank
6 TANKS Horizontal Tank
7 TANK EQUIPMENT FILLING VENTING & GAUGING DISPENSING SUPPLY & RETURN
8 TANK FILLING Horizontal Tank Top Fill
9 TANK FILLING Spill Containers/Fill Boxes Direct Top Fill
10 TANK FILLING Horizontal Tank Remote Filling
11 TANK FILLING Spill Containers/Fill Boxes Remote Fill
12 TANK FILLING Connections Quick Disconnect Dry Disconnect Quick Disconnect with Check Valves
13 TANK FILLING Connections Quick Disconnect with Check Valve & Cam-and-Groove Fitting
14 TANK FILLING Connections Tight-fill Delivery Connection
15 TANK FILLING Check Valves Swing Check Inline Check Wafer Check
16 TANK FILLING Block Valves Gate Valves Ball Valves
17 TANK FILLING Overfill Prevention Valves
18 TANK FILLING Overfill Prevention Valves
19 TANK FILLING Overfill Prevention Valves Control Line Orifice Valve Body Hydraulic Piston Float (open position)
20 TANK FILLING Overfill Prevention Valves Manual Test Device
21 TANK FILLING Drop Tube Drop Tube
22 TANK FILLING Vapor Recovery Equipment
23 TANK FILLING Vapor Recovery Equipment
24 TANK EQUIPMENT DISPENSING
25 TANK DISPENSING Types of Dispensing Systems Pressurized Suction
26 TANK DISPENSING Pressurized System Dispensing through a Pressurized System
27 TANK DISPENSING Suction System Dispensing through a Suction System
28 TANK DISPENSING Suction System Dispensing through a Suction System
29 TANK DISPENSING Anti-Siphon: Mechanical Valves
30 TANK DISPENSING Anti-Siphon: Electric Solenoid Valves
31 TANK DISPENSING Anti-Siphon: Electric Solenoid Valves Piloted Operated Zero Differential with Hung Piston De-Energized Energized
32 TANK DISPENSING Thermal Expansion CLOSED
33 TANK DISPENSING Thermal Expansion
34 TANK DISPENSING Emergency Valves
35 TANK DISPENSING Suction Strainer
36 TANK DISPENSING Heating Oil Generator Supply
37 TANK DISPENSING Generator Supply
38 TANK EQUIPMENT VENTING & GAUGING
39 VENTING & GAUGING Types of Venting Emergency Venting & Normal Venting
40 VENTING & GAUGING Emergency Venting
41 VENTING & GAUGING Emergency Venting Types of Emergency Vents Pop-Up Style Flip-Up Style Long-Bolt Manhole Rupture Disk
42 VENTING & GAUGING Emergency Venting
43 VENTING & GAUGING Emergency Venting Emergency Venting Operation
44 VENTING & GAUGING Emergency Venting UL 2583 Certified Emergency Vents UL 2583, an Outline of Investigation for Fuel Tank Accessories, is a revised testing protocol in which emergency vents have been given their own section and set of requirements. This is an update from the previous listing requirements to include modern automotive fuel compatibility and establish a standard testing protocol. Effective January 1, 2015
45 VENTING & GAUGING Normal Venting
46 VENTING & GAUGING Normal Venting
47 VENTING & GAUGING Normal Venting o Open vent allows free movement of air in and out of tank. Rain hood keeps water out. Vent height determined by authority having jurisdiction. Screen keeps bugs and debris out of tank. Vents outward and upward.
48 VENTING & GAUGING Normal Venting Vacuum Vents are very important
49 VENTING & GAUGING Normal Venting o Pressure/Vacuum Vent (Conservation Vent) Poppeted control of relief. Typical setting 2 oz. 8 oz. Pressure/1 oz. Vacuum. Conserves product and reduces vapor discharge. Vents outward and upward. UL 2583
50 VENTING & GAUGING Normal Venting Flame Arrestor Prevents the transmission of heat and/or an ignition source into the tank. Open Vent Arrestor Pressure Vacuum Vent Arrestor
51 VENTING & GAUGING Normal Venting Valves for Shop-Fabricated Tanks
52 VENTING & GAUGING Level Gauges Liquid Level Gauge: Reads feet and inches Liquid Level Gauge: Reads meters and centimeters
53 VENTING & GAUGING Level Gauges Liquid Level Gauge: Reads in gallons o o Tank-specific design Eliminates tank chart requirement Liquid Level Gauge: Reads in liters o o Tank-specific design Eliminates tank chart requirement
54 VENTING & GAUGING Level Gauges
55 VENTING & GAUGING EVR Approved System
56 VENTING & GAUGING Alarm Panels 918AC System Interface AC-powered Monitor 1 to 4 intrinsically safe input switch devices Audible and visual alarm indicators Up to 4 configurable relay outputs o o o Open or close valves Activate remote alarms Notify building security systems
57 VENTING & GAUGING Alarm Panels 918AC System Interface Common input sources
58 VENTING & GAUGING Adjustable Level Probes 924 (Brass) 924S (Stainless Steel)
59 Installation and Operation of AST Equipment Presenter: Steve Allwein Northeast Regional Sales Manager Morrison Bros. Co.
Diesel Exhaust Fluid Compatible Products DEF
Diesel Exhaust Fluid Compatible Products DEF Aboveground Installation Monitoring Cap & Adaptor 22 Vent 8 or 9 Anti-Siphon Valve or Solenoid Valve 24 Clock Gauge 29 Overfill Alarm Sensor 21 Overfill Shut-Off
More informationCommercial Semi-Instantaneous Water Heaters
FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory
More informationSilhouette. Feedwater Heater. Boiler Feedwater
Roth Roth Low Low Silhouette Silhouette TRAY DEAERATORS Boiler Boiler Feedwater Feedwater Heater Heater Capacities Capacities to to 50,000 50,000 lb/hr lb/hr Model RDTV-150-5-1-2 vertical tray type deaerator
More informationAbove Ground Fuel Tank Requirements
FIRE DEPARTMENT in cooperation with Above Ground Fuel Tank Requirements The purpose of this document is to provide information about general Fire Code requirements for above ground storage within the unincorporated
More informationTray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com
Tray ST5 Pressurized and Atmospheric Deaerators Tray Type Deaerator Pressurized.005 cc/liter COUNTER FLOW TRAY design provides guaranteed removal of all dissolved oxygen in excess of.005 cc/liter from
More informationUsed Fluid Handling Portable Used Oil Gravity Drains
Portable Used Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)
More information1.1 SECTION INCLUDES.1 Materials and installation for aboveground oil storage tanks..2 Section Waste Management and Disposal.
Page 1 of 8 PART 1 GENERAL 1.1 SECTION INCLUDES.1 Materials and installation for aboveground oil storage tanks. 1.2 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management
More informationSpray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com
Spray Flow II Pressurized and Atmospheric Deaerators.005 cc/liter Atmospheric Deaerator CONSTANT RECYCLING guarantees deaeration of all dissolved oxygen in excess of.005 cc/liter from 0% to 100% of deaerator
More informationSpray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com
Spray Flow II.00 cc/liter Atmospheric Deaerator Pressurized and Atmospheric Deaerators CONSTANT RECYCLING guarantees deaeration of all dissolved oxygen in excess of.00 cc/liter from 0% to 100% of deaerator
More informationMission Critical. Fuel Supply Systems
Fuel Supply Systems Insight Onsite Fuel Supply Systems Page 2 Simplex Mission Critical Fuel Supply Systems are comprehensive, integrated, project-matched fuel management systems for diesel and turbine
More informationFUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED
FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with
More informationA-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents
Boiler specifications A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents Burner General: Q. Burner and burner safeguards shall comply with the CGA
More informationUNFIRED STEAM GENERATORS STANDARD EQUIPMENT
CEMLINE Unfired Steam Generators are designed to produce clean steam with steam or high temperature hot water as an energy source for use where there is a need to produce clean steam from boiler steam
More informationMODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)
MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS) FOR PROPER AND SAFE USE OF THIS CHEMCHAMP EQUIPMENT, PLEASE FOLLOW THIS DOCUMENT AND LOCAL AUTHORITY. KEEP THIS DOCUMENT FOR FUTURE REFERENCE.
More informationPOWER VENTER SYSTEM. Model: PVO-300, PVO-600
POWER VENTER SYSTEM Model: PVO-300, PVO-600 Included is one ETL and cetl listed Power Venter to be used primarily with a single 120VAC controlled oil fired furnace, boiler, or water heater. The PVO may
More informationC. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.
SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More information.005 ATMOSPHERIC DEAERATOR
.005 ATMOSPHERIC DEAERATOR OCTOBER 1, 2007 GENERAL DESCRIPTION The Sellers atmospheric.005 deaerators condition make-up water and condensate returns to convert them into more desirable boiler feedwater.
More informationRefrigerant Valves/Accessories
Inline Check Valves Compact in-line (non-return) check valves for closure upon pressure reversals. Low Pressure Drop Mounts In Any Position Stainless Steel Disc Safe Working Pressure 400psig Operating
More informationDEAERATORS .005 ATMOSPHERIC DEAERATOR
918 W WALNUT ST, DANVILLE, KENTUCKY 40422-0048 PHONE (859) 236-3181 www.sellersmfg.com SPECIFICATION SHEET NO. 3300 DEAERATORS.005 ATMOSPHERIC DEAERATOR GENERAL DESCRIPTION The Sellers atmospheric.005
More informationHORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).
SECTION 15555 HORIZONTAL FIRE TUBE BOILERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15510 - Piping (HVAC). 2. 15540 - Pumping Equipment (HVAC). 1.02 SUBMITTALS A. Submit properly identified
More informationPOWER VENTER. Model: PVE Series
POWER VENTER Model: PVE Series CONTENTS Typical Venting System Components... System Operation... Power Venter Sizing... Installation Safety Instructions... Installation of Power Venter... Connecting Power
More informationLubrication Tools and Equipment Portable Oil Drains
Portable Oil Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s) into a portable
More informationUSED OIL DRAIN WITH BLOWBACK SAFETY FEATURE
DRAIN WITH BLOWBACK SAFETY FEATURE P/N 24175G Now you can avoid spills and eliminate the mess associated with collecting used oil and similar fluids. This used oil drain offers a handy and practical method
More informationSeries 300 VTB. Installation Instructions
Series 300 VTB Installation Instructions Sizes 7 12 16 20 30 HP #2 Fuel Oil Gas (500 to 2500 BTU) Gas Light Oil Combination High Pressure Steam Sizes 7 thru 16 HP (125 PSI) Sizes 20 and 30 HP (150 PSI)
More informationENSPECO Recovery/ Recycle/ Evacuate/ Recharge
ENSPECO Recovery/ Recycle/ Evacuate/ Recharge RMS 3012 RMS 3034 Approved by UL/SAE to J-1991 R12 Purity Standards Approved by UL/SAE to J-2210 R134 Purity Standards This semi-automatic machine will recover
More informationFlammable Materials SC-127
Risk Management Flammable Materials Safety Challenges Many types of flammable and combustible materials/liquids are used in today s workplace. As the person responsible for safety at your company, you
More informationTECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE
Page 1 of 12 1. (Refer to Figures 1-7.) Viking supervised Single-Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system. The system piping
More informationEssex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL
Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 SECTION 232116 - HYDRONIC PIPING SPECIALTIES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions
More informationModel DDX Deluge Valve
Model DDX Deluge Valve Bulletin 510 Bulletin 510 Features 1. Differential type, simple, lightweight, dependable construction. 2. Simply and easily trimmed for releasing by: Manual pull stations Wet pilot
More informationUsed Fluid Handling Portable Used-Oil Gravity Drains
Portable Used-Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)
More informationSECTION HEATING BOILER FEEDWATER EQUIPMENT
SECTION 23 53 00 HEATING BOILER FEEDWATER EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes boiler feedwater pumps, de-aerators, accessories, controls and tanks. 1.2 REFERENCES A. ASME (American
More informationSPECIFICATIONS MODEL E859C MINI DEHYDRATOR
SPECIFICATIONS MODEL E859C MINI DEHYDRATOR 1 DEHYDRATION TECHNOLOGY This proposal describes the equipment which shall be supplied by ENERVAC for a system for processing (dehydrating, de-aerating, purifying
More informationLABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS
SECTION 22 20 00 LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",
More informationAir Eliminator
Cat alog Title Catalog Subtitle 730-20 Air Eliminator Principle Operation & Maintenance Manual Page 2 Table of Content Safety Warning Symbols 2 Air Elimination Principle 2 Air Eliminator Principle (Continuted)
More informationCritical Equipment. Testing Procedures / Frequency
Testing s / 1. FIRE, SMOKE AND HEAT DETECTION SYSTEMS These systems include the detection devices, the master control cabinet(s) which house the systems logic boards, the wiring to solenoids or end devices,
More informationRevitalize Building Mechanical Systems (4619)
SECTION 235216 FIRE-TUBE CONDENSING BOILERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationAM SELECT DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES VOLTAGE. Item # Quantity C.S.I. Section AM15
AM SELECT DISHWASHER Item # Quantity C.S.I. Section 11400 AM SELECT DISHWASHER STANDARD FEATURES.74 gallons per rack final rinse water 58 racks per hour hot water sanitizing 65 racks per hour chemical
More information215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions
215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions Lanair Products LLC 4109 Capital Circle Janesville, Wisconsin 53546 1-888-370-6531 www.lanair.com BEFORE YOU BEGIN INSTALLATION...
More informationPHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps
Note: The A/E must choose all design values in brackets below before using in project specifications 1 General 1.1 Provide UL listed and FM approved fire pump complete with pump, driver, controller and
More informationLEAK TEST FREQUENCY: a. CONTINUOUS b. DAILY/NIGHTLY c. WEEKLY. d. MONTHLY e. OTHER (Specify):
UNDERGROUND STORAGE TANK MONITORING PLAN For use by Unidocs Member Agencies or where approved by your Local Jurisdiction Authority Cited: Title 23 CCR, Sections 2632(d)(1), 2634(d)(2), and 2641(h) TYPE
More informationSECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY
SECTION 22 11 23.13 DOMESTIC WATER PRESSURE BOOSTING PART 1 - GENERAL 1.1 SUMMARY A. Where utility water pressure cannot adequately meet the pressure requirements of the domestic water systems and where
More informationInternational Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries
International Reactor Bulletin 1100 Corporation Standard and Custom Reactors for the Chemical Process Industries 2 International Reactor Corporation 521 Kiser Street Dayton, Ohio 45404-1641 Phone: 937-224-4444
More informationXIII Troubleshooting
XIII Troubleshooting The following pages contain troubleshooting charts for use in diagnosing control problems. To use these charts, go to the box marked Start at the top of the chart on page 34 or 36
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE PUMP REVIEW Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved; AC-Approved w/comments;
More informationLATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners
1 1. General Installation Information (to be completed by technician) Date installed: Location (city & state): Cleaner s name: National Board number (boiler): Installed by (company): Installed by (technician):
More informationPreventative Maintenance Tables
Preventative Maintenance Tables Table of Contents I. Table : Gas Fired Domestic Hot Water Heater II. III. IV. Table : Circulating Pump Table : Convectors Table 4: Grille and Diffusors V. Table 5: Unit
More informationSECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS
SECTION 237413 - PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, outdoor, central-station air-handling units (rooftop units) with the
More informationCaresaver Universal Refrigerant Recovery Unit
Operation Manual Caresaver Universal Refrigerant Recovery Unit 2 CONTENTS CHAPTER 1 INTRODUCTION AND OVERVIEW Specifications 3 Health and Safety 4-5 Component Location and Identification 6-9 CHAPTER 2
More information! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-315(C)
Models 51, 51-S and 53 Boiler Water Feeders Models 51-2, 51-S-2 and 53-2 Feeder Cut-Off Combinations McDonnell & Miller Installation & Maintenance Instructions MM-315(C) OPERATION Maximum Water Supply
More informationSpecifications 3. Bladder 5. Chimney 12. Air Supply 12. Anti-Rollout Device and Ash Auger Tube 14. Timer 15
TABLE OF CONTENTS Page No. Specifications 3 Bladder 5 Fire Door 7 Chimney 12 Air Supply 12 Anti-Rollout Device and Ash Auger Tube 14 Timer 15 Supply Line and Return Line Threaded Connectors 15 Low Water
More informationPackaged Semi-Instantaneous Steam Fired Water Heater
MODEL STX Packaged Semi-Instantaneous Steam Fired Water Heater Shell and Tube Style Heater Features Reliable Only high grade materials used in construction to ensure long operating life Heat exchange pressure
More informationBid Specifications for Thermo-Lay model UD /4 yard truck mounted machine with hydraulic bins & roller DIMENSIONS: Body:
DIMENSIONS: Body: 142" long, 78" wide, 43" high Total Height above ground: 98" Cab to trunion required: 138" Wheel base required: 204" on Freightliner FL 70 Turning radius: 55' curb to curb on Freightliner
More informationC. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.
Buchtel/Perkins Community Learning Center GPD -2007271.15 OSFC Project # 55-7110-9029425 Phase 3 CLC Package Bidding Documents July 1, 2010 SECTION 15513 CONDENSING BOILERS PART I- GENERAL 1.1 RELATED
More informationHIGH PRODUCTIVITY MAXIMUM PAYLOAD PACKAGED IN A LIGHTER WEIGHT DESIGN
HIGH PRODUCTIVITY MAXIMUM PAYLOAD PACKAGED IN A LIGHTER WEIGHT DESIGN The Vactor HXX Series of HydroExcavators, are proven leaders in hydroexcavation, with a full line of powerful machines that safely
More informationBoiler Condensate Return Basics. Presented by Steve Connor February 24, 2016
Boiler Condensate Return Basics Presented by Steve Connor February 24, 2016 What We Are Covering Today? Brief review of the total steam system Why a proper condensate return system is so important Condensate
More informationSECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS
SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from
More informationUser s Information Manual Models: 45, ,000 Btu/hr
SBR-USER_100161678_2000017137_Rev C User s Information Manual Models: 45,000-260,000 Btu/hr If the information in this manual is not followed exactly, a fire or explosion may result causing property damage,
More informationPVE SERIES POWER VENTER SYSTEM MANUAL
PVE SERIES POWER VENTER SYSTEM MANUAL Contents Page I. Typical Venting System Components 2 II. System Operation 3 III. Power Venter Sizing 3,4 IV. Installation Safety Instructions 5,6 V. Installation of
More informationINTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION
INSTALLATION AND OPERATING INSTRUCTIONS FOR THE HARDY Fuel Oil Furnace Models D-140 & D-350 HARDY MANUFACTURING COMPANY, INC. 12345 ROAD 505 PHILADELPHIA, MS 39350 PHONE: (601) 656-5866 FAX: (601) 656-4559
More informationGASEOUS HYDROGEN SYSTEMS
CHAPTER 7 GASEOUS HYDROGEN SYSTEMS SECTION 701 GENERAL 701.1 Scope. The installation of gaseous hydrogen systems shall comply with this chapter and Chapters 30 and 35 of the Fire Compressed gases shall
More informationAQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: AP AQUAS Pool Package
100285340_2000542910_Rev A AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: AP 400-850 AQUAS Pool Package The AQUAS pool package system is a high efficiency commercial condensing boiler, pre-piped
More informationTotalPac X Single interlock SUREFIRE system
DESCRIPTION This TOTALPAC X integrated fire protection system by FireFlex Systems Inc. consists of a trim totally preassembled, pre-wired and factory tested. All electrical and mechanical components of
More informationSECTION STEAM CONDENSATE PUMPS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 22 23 STEAM CONDENSATE PUMPS SPEC WRITER NOTES: 1. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable
More information2016 Plumbing Supplemental Plan Review List
Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Plumbing Supplemental Plan Review List POTABLE WATER SYSTEM P1. Specify which fixtures are for private use and which are for
More informationLow pressure boiler* inspection and maintenance
2-12.001 May 2011 Low pressure boiler* inspection and maintenance Introduction Even as our society evolves into a more technologically advanced, economically driven environment, many businesses and their
More informationGENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.
GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO. GBI 201-5 3C For a proper installation and in order to receive the best in operating life and efficiency from your
More informationSECTION PLUMBING EQUIPMENT
PART 1 GENERAL 1.01 SECTION INCLUDES A. Water heaters. B. Packaged water heating systems. C. Domestic water heat exchangers. D. Water storage tanks. E. Water softeners. F. Reverse osmosis equipment. G.
More informationStatement of Responsibilities
Statement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and
More informationUser s Information Manual
User s Information Manual Galaxy GG, GXH & GXHA Series, Sentry Series and Sentinel SE Series Gas Boilers with Intermittent Pilot Ignition Device System (IID) FOR YOUR SAFETY: Before operating this boiler,
More informationUser s Information Manual Galaxy GG/GX Series, Sentry S/SX Series and Sentinel SE Series Gas Boilers with Continuous Burning Pilot
User s Information Manual Galaxy GG/GX Series, Sentry S/SX Series and Sentinel SE Series Gas Boilers with Continuous Burning Pilot FOR YOUR SAFETY: Before operating this boiler, READ this manual. DO NOT
More informationTECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5
Page 1 of 5 1. SYSTEM DESCRIPTION Viking supervised, single interlocked preaction pre-primed systems utilize a Viking Deluge Valve (A.1) and a hydraulically pressurized automatic sprinkler system. The
More information150 BHP, 3 Pass High-Pressure Fire Tube Boiler mounted in a 53 Trailer
March 1, 2017 150 BHP, 3 Pass High-Pressure Fire Tube Boiler mounted in a 53 Trailer Customer Carey Boiler Works March 1, 2017 Page 2 of 5 Section 10 Boiler... 2 10.1... 2 10.2 Design... 2 10.3 Technical
More informationTotalPac X Firecycle III Preaction Double interlock system
DESCRIPTION This TOTALPAC X integrated fire protection system by FireFlex Systems Inc. consists of a multicycling Firecycle III system trim totally pre-assembled, pre-wired and factory tested. All electrical
More informationAFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh
WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION
More informationAM-14/AM-14C DISHWASHERS
AM-14/AM-14C DISHWASHERS Item # Quantity C.S.I. Section 11400 AM-14/AM-14C DISHWASHERS STANDARD FEATURES 53 racks per hour hot water sanitizing 16 gauge stainless steel tank, chamber, doors, frame and
More informationInstallation & Operation Manual Models:
SJS-I-O Rev C Installation & Operation Manual Models: 60-119 : If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss
More informationBERMAD Fire Protection
Model: 400E-3M Bermad Electro-Pneumatically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Safety First BERMAD believes that the safety of personnel working with
More informationTECHNICAL DATA. 319a. January 27, 2012
January 27, 2012 319a 1. DEsCrIpTIoN (Refer to Figures 1-3.) Viking Electric/Pneumatic Double Interlocked Preaction Systems utilize a Viking deluge valve controlled by a pneumatic actuator (E.1), normally
More informationVitodens 100W WB1B - Service and Maintenance
- Service and Maintenance Foil 2, 11/2015 Viessmann Manufacturing W 10-26: 37-91 MBH input. W 10-35: 37-118 MBH input. Natural Gas or LPG (conversion kit supplied with boiler). Altitudes up to 10,000 ft.
More informationAuto Service Test Review. For the Most Effective Personal Review, Match the Following Questions to the On Line Study Guide Multimedia
Auto Service Test Review For the Most Effective Personal Review, Match the Following Questions to the On Line Study Guide Multimedia Auto Service Test Review Test #3 73 Questions from: Chapters 39 & 40
More informationearth safe Fuel Systems for Critical Power
BACnet, Modbus, Metasys N2, or LON Communications General Description Safe Fuel Storage Inside Buildings. Earthsafe day tanks safely store fuel for generarator engine consumption within the building. Day
More informationMotor Vehicle Air Conditioning (MVAC) System operation and the refrigerant cycle
Motor Vehicle Air Conditioning (MVAC) System operation and the refrigerant cycle At Sea level water boils at 212⁰ F R 134a boils at 15⁰ F At Sea level R 134a boils at 15⁰ F At 30 psig R 134a boils at 35⁰
More informationC. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.
SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers
More informationCondensate Return Feedwater Systems For Low and High Pressure Steam Boilers
For Low and High Pressure Steam Boilers Rite s feedwater return systems are engineered for the safe and efficient storage and pumping of condensate and make-up water back to the boiler. Why Rite? Because
More informationModel: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance
Model: 400E-5M Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset Installation Operation Maintenance Application Engineering Bermad 1. Safety First BERMAD believes
More informationUniversity of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL
SECTION 21 30 00 FIRE PROTECTION PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 01 00,
More informationA System That Utilizes the LD-2000 or LD-3000 Mechanical Line Leak Detector to Perform 3 10 PSI (catastrophic) Line Tests
Overview of the A System That Utilizes the LD-2000 or LD-3000 Mechanical Line Leak Detector to Perform 3 GPH @ 10 PSI (catastrophic) Line Tests Meet EPA Hourly Test Requirement by Performing Line Tests
More informationFire Bowls and Fire Bowl Inserts (Automated Operation) Operating and Maintenance Instructions
Table of Contents Section 1: Gas and Electric Requirements... 1 Section 2: Installation... 2 Section 3: Burner Setup and Adjustment... 8 Burner Adjustment... 9 Section 4: Maintenance... 10 Section 5: Operation...
More informationPrecisionTemp Shower-Mate
Shower-Mate Instantaneous Gas Water Heater Installation and Operating Instructions The Shower-Mate is a power vented automatic instantaneous water heater designed to be installed in ventilated marine applications.
More informationTECHNICAL DATA OBSOLETE
January 27, 2012 311a 1. DEsCrIpTIoN (Refer to Figures 1-3.) Viking supervised Single Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system.
More informationSINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE
SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE HD FIRE PROTECT TECHNICAL DATA SIZE DELUGE VALVE CHECK VALVE SPRINKLER ALARM RELEASE PANEL 50, 80, 100, 150 & 200 NB Model H3, UL Listed
More informationAriazone 5001 HFO-1234yf
Automotive Air-Conditioning Service Equipment Ariazone 5001 HFO-1234yf OPERATOR MANUAL 1 Contents Page 1. Introduction... 3 2. Safety... 4 3. Technical Features... 5 4. Main Parts & Features... 6 5. Preparing
More informationR100 Oil-Less Refrigerant Recovery Unit
R100 Oil-Less Refrigerant Recovery Unit Operation Manual 1 INTRODUCTION Welcome to simple, efficient refrigerant recovery with your new YELLOW JACKET Refrigerant Recovery Unit, R100. This unit combines
More informationService Manual. Models 17700/17701/17703 Recovery/Recycling/Recharging Unit For R-12 Only
Service Manual Models 17700/17701/17703 Recovery/Recycling/Recharging Unit For R-12 Only Theory of Operation and Safety Precautions... 2 Component Descriptions... 3 Plumbing Diagram... 8 Pictorial Views...
More information.03 ATMOSPHERIC DEAERATOR
.03 ATMOSPHERIC DEAERATOR SPECIFICATION SHEET NO. 3200 OCTOBER 1, 2007 GENERAL DESCRIPTION The Sellers atmospheric.03 deaerators condition make-up water and condensate returns to convert them into more
More informationOPERATION & MAINTENANCE MANUAL TX600
OPERATION & MAINTENANCE MANUAL TX600 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80118-00 (Rev B) ! TABLE OF CONTENTS! TX600 Before Using Page 2 Safety Precautions Page
More informationHeat Reclaim. Benefits,Methods, & Troubleshooting By Dave Demma, Manager Supermarket Sales, Sporlan Division - Parker Hannifin Corporation
Form 30-217 / January 2007 Heat Reclaim Benefits,Methods, & Troubleshooting By Dave Demma, Manager Supermarket Sales, Sporlan Division - Parker Hannifin Corporation While the vapor-compression cycle has
More informationD. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationCHAPTER 10 STEAM AND HOT WATER BOILERS
CHAPTER 10 STEAM AND HOT WATER BOILERS 1001.0 Purpose. The purpose of this chapter is to establish and provide minimum standards for the protection of public welfare, health, safety, and property by regulating
More informationContour TM Screw Compressors
Contour TM Screw Compressors Semi-Hermetic Compact Operating Instruction SCH1 High Temp Compressors Form No. 99-77 1. Introduction This series of semi-hermetic compact screw compressors is designed for
More information