FM458/CMC 930. Strategy module. Service instructions. For contractors. Read carefully prior to commissioning or service.

Size: px
Start display at page:

Download "FM458/CMC 930. Strategy module. Service instructions. For contractors. Read carefully prior to commissioning or service."

Transcription

1 Strategy module FM458/CMC 930 For contractors Read carefully prior to commissioning or service (2011/06) GB / IE / AU Service instructions

2 2 1 Safety About these instructions Determined use Standards and directives Explanation of the symbols used Observe this information Disposal Product and function description Front panel Switch on the module PCB Module recognition switch Voltage/current output Terminology key EMS boiler CAN boiler Mixed cascade Series operation Parallel operation Boiler sequence Load limit Installation Scope of supply Checking the software versions Installation in the CFB 930 control unit Connecting inputs and outputs Connecting sensors Connecting EMS boilers Assigning the boiler number Recommended hydraulic schemes CAN boiler via low loss header EMS boiler via low loss header EMS boiler with EMS DHW CAN boilers in series CAN boilers in parallel CAN boilers in "Tichelmann System" (2011/06) FM458/CMC 930 Strategy module

3 Twin-block boiler according to the "Tichelmann principle" Mixed cascade via low loss header System with different EMS boilers Integrating EMS boilers Base controller BC Functions of the FM458/CMC Operation with Programmer Integrating function module FM458/CMC 930 in the control unit Integrate function module FM458/CMC 930 on Programmer level Integrate function module FM458/CMC 930 manually on Programmer level General specification data V input Temperature control 0 10 V input Output control for 0 10 V input Strategy data Number of boilers Maximum system temperature Hydraulic decoupling Boiler sequences Sequence switching "Sequence revers. none" Sequence reversal subject to hours run Sequence reversal subject to outside temperature "Sequence revers daily" "Sequence reverse external contact" Load limit Load limit according to outside temperature Load limit via external contact Operating mode serial / parallel Lead boiler run-on time (pump/servomotor) Lag boiler run-on time (pump/servomotor) FM458/CMC 930 Strategy module (2011/06)

4 4 8 DHW data Selecting the DHW cylinder Setting the temperature range Selecting switching optimisation Selecting residual heat use Setting hysteresis Selecting and setting up thermal disinfection Setting the thermal disinfection temperature Setting the day of the week for thermal disinfection Setting the time for thermal disinfection Daily heat-up Selecting the DHW circulation pump Setting the DHW circulation pump intervals Recording heat consumption Setting the recording of heat demand "acc. to impulses" Matching the impulse value Scanning heat demand Restarting the heat consumption count Relay test Fault log Fault messages Strategy monitor data EMS boiler EMS boiler monitor data Supplementary fault messages with EMS Maintenance messages for boilers with EMS Technical data Function module FM458/CMC Sensor curves Keyword index (2011/06) FM458/CMC 930 Strategy module

5 Safety 5 1 Safety 1.1 About these instructions This chapter contains general safety instructions which must be observed during service work on the FM458/CMC 930 function module. Also closely observe the further safety instructions, which you can find in other chapters of these service instructions. Carefully read the safety instructions before commencing the work described below. If safety instructions are ignored, severe or even fatal injuries may result, as well as material losses and environmental damage. 1.2 Determined use You can integrate the function module FM458/CMC 930 into the control units CFB 910 and CFB 930. For faultless operation, you will need at least software version 8.xx for the control unit and Programmer programming unit. 1.3 Standards and directives The design and operation of this product conforms to the European Directives and the supplementary national requirements. Its conformity is confirmed by the CE designation. You may request the declaration of conformity. For this see the contact address at the back cover of these instructions. FM458/CMC 930 Strategy module (2011/06)

6 6 Safety 1.4 Explanation of the symbols used Two levels of danger are identified and signalled by the following terms: RISK OF FATAL INJURY WARNING! Identifies possible risks associated with a product that might lead to serious injury or even death if appropriate care is not taken. RISK OF INJURY/ SYSTEM DAMAGE CAUTION! Identifies potentially dangerous situations, which might lead to medium or slight injuries or to material damage. USER INFORMATION User tips for the optimum utilisation and adjustment of the appliance plus other useful information. 1.5 Observe this information The FM458/CMC 930 function module was designed and built according to the state of the art and the recognised safety-related standards. However, material losses resulting from inappropriate service work cannot be completely prevented (2011/06) FM458/CMC 930 Strategy module

7 Safety 7 Before commencing service work on the FM458/CMC 930 function module, read these service instructions carefully. RISK OF FATAL INJURY WARNING! from electric shock! The installation, electrical wiring, commissioning, electrical connection, as well as maintenance and repairs must only be carried out by a competent contractor who adheres to all current technical regulations and requirements. Regional regulations should be observed in this regard! RISK OF FATAL INJURY WARNING! from electric shock! Ensure that all electrical work is only carried out by an authorised electrician. Before opening the control unit: Isolate all poles of the power supply and secure against unintentional reconnection. RISK OF FATAL INJURY from electric shock! WARNING! The risk of voltage flashes through unintentional loosening of the cores at the terminals between the 230 V and the LV must be prevented. Therefore fix the wires from each cable away from each other (e.g. with cable ties) or only strip the wire for a very short section. FM458/CMC 930 Strategy module (2011/06)

8 8 Safety RISK OF INJURY/ SYSTEM DAMAGE CAUTION! from operator error. Operator errors can result in injury and damage to property. Ensure that children never operate the appliance unsupervised or play with it. Ensure that only personnel able to operate the appliance correctly have access to it. DAMAGE TO THE APPLIANCE CAUTION! from electrostatic discharge (ESD). Before unpacking the module touch a radiator or an earthed metal water pipe to discharge any electrostatic charge in your body. USER INFORMATION Ensure that a regulation isolator is available to disconnect all poles from the mains power supply. Install an isolator if none is available. USER INFORMATION Only use original Bosch spare parts. Losses caused by the use of parts not supplied by Bosch are excluded from the Bosch warranty. 1.6 Disposal Electronic components must not be disposed of with general domestic waste. Dispose of old modules correctly through an authorised disposal site (2011/06) FM458/CMC 930 Strategy module

9 Product and function description 9 2 Product and function description USER INFORMATION This module can only be installed in the master with address 0 or 1. The function module FM458/CMC 930 is designed exclusively for use in the modular control system CFB 930. You can integrate the function module FM458/CMC 930 once or twice into a control unit of the control system CFB 930. The main function of the function module FM458/CMC 930 consists in operating a multi-boiler system according to your requirements. You can use the following functions or connection options after installing the FM458/CMC 930 function module: Module for use with control unit CFB 910 or CFB 930 any combination of boilers with 1-stage, 2-stage and modulating burners, and control system CFB 930 and/or control system EMS maximum of 8 boilers as the module can be used 2 x. Operation in parallel or series to take system-specific standard efficiencies into account Load limit either according to outside temperature or external contact Sequence reversal for boilers either daily, according to outside temperature, hours run or an external contact Central fault message function via relay with zero volt contact programmable 0-10 V input for external set value hook-up as set temperature or default output programmable 0-10 V output for external set temperature demand DHW heating via EMS of boiler 1 FM458/CMC 930 Strategy module (2011/06)

10 10 Product and function description Heat meter input Internal communication via data BUS Encoded and colour-coded connection plugs Continued operation in case of faults (2011/06) FM458/CMC 930 Strategy module

11 Product and function description Front panel Fig. 1 Front panel FM458/CMC 930 function module 1 LED boiler 4 enabled 2 LED boiler 3 enabled 3 LED boiler 2 enabled 4 LED boiler 1 enabled 5 LED "Module fault" (red) general module fault 6 LED DHW active via EMS boiler 1 7 LED flow too cold, therefore higher output 8 LED flow too hot, therefore lower output 9 LED flue gas test active FM458/CMC 930 Strategy module (2011/06)

12 12 Product and function description 2.2 Switch on the module PCB Module recognition switch With this switch, the function module FM458/CMC 930 can be configured as the function module FM447 in the case of replacement. This is required in older systems with software versions below 8.xx, which do not yet recognise the FM458/CMC 930. Position Function FM458/ CMC 930 The module logs on as FM458/CMC 930. FM458/ CMC 930 The module logs on as FM447. USER INFORMATION The functions described in this document will not be available if the switch is set to FM447. For information regarding parameterisation, please see the service instructions for the control unit CFB 910 or CFB (2011/06) FM458/CMC 930 Strategy module

13 Product and function description 13 FM458/ CMC 930 FM458/ CMC ITL Fig. 2 Position module recognition switch FM458/CMC 930 Strategy module (2011/06)

14 14 Product and function description Voltage/current output With the slide switch (voltage/current output), you can configure the output of the temperature demand (terminal U 3,4). Slide switch set to U: The temperature demand is issued as a voltage from 0 to 10 V. Slide switch set to I: The temperature demand is issued as a current from 0 ma to 20 ma. You can freely assign voltage or current (see Chapter 6.1 "0 10 V input", page 58). Fig. 3 Slide switch voltage/current output FM458/CMC Slide switch (factory setting 0 10 V) (2011/06) FM458/CMC 930 Strategy module

15 Product and function description Terminology key EMS boiler EMS boilers are boilers which are equipped with an energy management system, i.e. wall mounted boilers with UBA 3.x or floor standing boilers with MX10/MX15 and burner control unit CAN boiler CAN boilers are boilers which are connected to the control unit CFB 910/930 via the standardised 7-pole burner plug for stage 1 or the 4-pole burner plug for stage 2 or modulation Mixed cascade A mixed cascade is a multi-boiler system with up to 8 boilers in which completely different boiler types can be combined with each other, e.g. a) floor standing CAN boilers with EMS wall mounted boilers b) floor standing EMS boilers with EMS wall mounted boilers c) floor standing CAN boilers with floor standing EMS boilers or d) floor standing CAN boilers with floor standing boilers EMS boilers with EMS wall mounted boilers FM458/CMC 930 Strategy module (2011/06)

16 16 Product and function description Series operation In operation in series, the next boiler in the sequence will only be enabled if the previous boiler has reached 100 % of its output. Fig. 4 Diagram "Operation in series" 1 Boiler 1 (modulating burner) 2 Boiler 2 (modulating burner) 3 Boiler 3 (2-stage burner) 4 On/Off mode x Total heating system output y Heating system heat input (2011/06) FM458/CMC 930 Strategy module

17 Product and function description Parallel operation In parallel mode, the boilers are jointly matched to the demand. With this operation, the strategy function first enables the base stage of boiler 1, then the base stage for boiler 2 etc. When all boilers operate at their base stage, all boilers are modulated in parallel. Fig. 5 Diagram "parallel operation" 1 Boiler 1 2 Boiler 2 3 Boiler 3 4 On/Off mode x Total heating system output FM458/CMC 930 Strategy module (2011/06)

18 18 Product and function description Boiler sequence Alongside the individual power stages and their enabling, the function module FM458/CMC 930 manages the sequence of boiler switching. This determines which boiler functions as lead boiler and whether or in what circumstances the sequence will be reversed. The sequences of the different boiler circuits can be defined automatically (by the FM458/CMC 930) or manually. Five setting options are available for sequence reversal: "No sequence reversal" (manual boiler sequence selection) The system operator specifies a set boiler sequence that is always observed. The option "No sequence switching" must be set for the strategy at the service level on the Programmer programming unit. Daily sequence switching The strategy function switches to a different boiler sequence cyclically at 00:00 hours every day (2011/06) FM458/CMC 930 Strategy module

19 Product and function description 19 Boiler sequence reversal after hours run The boiler sequence is selected in accordance with the hours run. This means that the strategy function switches to a different boiler sequence cyclically at 00:00 if the relevant lead boiler has exceeded a set number of hours of operation. Fig. 6 Boiler sequence reversal after hours run 1 Boiler 1 2 Boiler 2 3 Boiler 3 4 Lead boiler change-over 5 Hours run by the heating system FM458/CMC 930 Strategy module (2011/06)

20 20 Product and function description Sequence reversal subject to outside temperature The boiler sequences A, B, C and D are selected subject to the outside temperature. The temperature changeover thresholds are freely adjustable (settings see Chapter 7.5 "Sequence switching", page 72). The following table shows an example for the different boiler sequences (in automatic mode by the FM458/CMC 930). Number of boilers 4th Zone Sequence D 3rd Zone Sequence C 2nd Zone Sequence B 1st Zone Sequence A Temperature changeover thresholds 5 C 10 C 15 C Tab. 1 Factory-set boiler sequences (automatic) Load limit The load limit (for settings, see Chapter 7.6 "Load limit", page 80) prevents the starting of lag boilers that are not required if high heat demands are strictly peak loads. The load limit function enables the number of boilers to be matched to lower system loads, e.g. during spring and autumn. Boilers that are not required are disabled. However, the load limit will be lifted if inadequate heat is provided due to faults in an individual boiler. The following dependencies can be drawn into consideration for blocking the lag boiler using the load limit function (2011/06) FM458/CMC 930 Strategy module

21 Product and function description 21 Load limit according to outside temperature This function blocks the lag boiler automatically depending on a set outside temperature (setting range of 0 C to +30 C). Fig. 7 Diagram "Load limit at outside temperature" 1 Zone 3 2 Zone 2 3 Zone 1 x Temperature thresholds y Number of boilers Subject to the number of boilers, up to 2 temperature thresholds can be defined. The outside temperature raneg is thus subdivided into up to 3 zones. Zone 1 is the high outside-temperature range. For this zone, the number of enabled boilers can be adjusted. As the outside temperature falls, additional boilers are allowed. All boilers can be enabled in zone 3. In heating systems with more than 3 boilers, boilers are variably enabled in zone 2 as the outside temperature drops (setting see Chapter 7.6 "Load limit", page 80). FM458/CMC 930 Strategy module (2011/06)

22 22 Product and function description Load limit via external isolated contact An adjustable number of boilers can be blocked via the external zero volt contact (on-site connection to terminal EL in the FM458 / CMC 930 function module). All boilers can be blocked. This enables all boilers to be shut down, for example if external heat sources are available (2011/06) FM458/CMC 930 Strategy module

23 Installation 23 3 Installation 3.1 Scope of supply Check the delivery for completeness. Fig. 8 Scope of supply for function module FM458/CMC Heat conductive paste 2 9 mm sensor as contact sensor 1) 3 Function module FM458/CMC Fixing material for 9 mm sensor 1) Subject to the installation situation, the sensors can be used for the sensor connections listed in Tab. 3, page 26. The curves are identical. Not shown: Operating instructions, service instructions, wiring diagram FM458/CMC 930 Strategy module (2011/06)

24 24 Installation 3.2 Checking the software versions The software versions of the controller module CM 431 and the Programmer programming unit must be at least version 8.xx. Before installing the function module FM458/CMC 930, check the software version of the controller module CM 431 and the Programmer programming unit at the service level (at least Version 8.xx). You can obtain more detailed information from any Bosch branch. 3.3 Installation in the CFB 930 control unit Generally, you can fit the FM458 / CMC 930 function module into any vacant slot in the CFB 9x0 of the series CFB 930 (e.g. slot 1 4 in the CFB 9x0). USER INFORMATION Advice: Arrange the function module FM458/CMC 930 as far right as possible. This achieves a logical assignment of the heating circuits. The heating circuit modules should be inserted in the control unit starting from the left-hand side (slot 1). Exception: certain function modules must be installed in designated slots. This module can only be installed in the master control unit with ECO-CAN bus address 0 or (2011/06) FM458/CMC 930 Strategy module

25 Installation 25 Fig. 9 Slot assignment 1 4 (Example CFB 9xx) 1 Slot 1, e.g. FM442/CMM 920 (heating circuit 1, heating circuit 2) 2 Slot 2, e.g. FM442/CMM 920 (heating circuit 3, heating circuit 4) 3 Slot 3: e.g. FM441/CMM 910 (heating circuit 5, DHW/circulation pump) 4 Slot 4: e.g. FM458/CMC 930 (strategy, for multi-boiler systems) 3.4 Connecting inputs and outputs The LV terminals and the 230 V outputs are available at the rear top of the FM458/CMC 930 function module. Coloured labels with inscriptions matching the appropriate plugs are fitted to the strips. Plugs are colour-coded and inscribed. Connect inputs and outputs correctly. For further information, see see Chapter 3.8 "Recommended hydraulic schemes", page 32 to Page 50. Fig. 10 FM458/CMC 930 Strategy module (2011/06)

26 26 Installation Designation AS Description Output central fault message, zero volt min. breaking capacity 12 V/20 ma max. breaking capacity 230 V/5 A Tab. 2 Inputs and outputs (terminal designation) 3.5 Connecting sensors The sensor connections are on the back side of the function module FM458/CMC 930. Coloured labels with inscriptions matching the appropriate plugs are fitted to the strips. Plugs are colour-coded and inscribed. Sensor designation key FVS FRS ZW EL U in 1/2 U out 3/4 Tab. 3 Designation Fühler Vorlauf Strategie [Strategy flow sensor] Fühler Rücklauf Strategie [Strategy return sensor] Zählereingang Wärmemengenzähler [Meter input - heat meter] Eingang Lastbegrenzung [Load limit input] Voltage input 0 10 volt Output 0 10 volt Sensor connections Function This sensor is used to regulate a multi-boiler system. It defines the heat transfer point from the boiler to the system (system flow). This sensor is used to regulate the operating conditions of a multi-boiler system. It defines the system return. An external heat meter can be connected via a zero volt contact to this terminal; this can be evaluated in the statistic function. Option: Input for external boiler sequence reversal. This input enables the system to be operated externally, dependent either on flow temperature or output; the system flow sensor acts as a reference point. This output informs the external control system about the current set system flow temperature (2011/06) FM458/CMC 930 Strategy module

27 Installation 27 USER INFORMATION Ensure that you connect the sensors correctly and in the correct positions. For further information, see Chapter 3.8 "Recommended hydraulic schemes", page 32 and following. USER INFORMATION When using two FM458/CMC 930 modules, connect the temperature sensors, the heat meter sensor, and the external sequence changeover and the external load limit to the module that is connected to boiler 1. If the voltage inputs are connected to each module as the default set temperature, the highest temperature will be used as the set value for the strategy. The voltage and fault message outputs are identical for both modules. 3.6 Connecting EMS boilers The connections for connecting EMS boilers are at the rear top of the FM458/CMC 930 function module. Labels with inscriptions matching the appropriate plugs are fitted to the strips. EMS 1 EMS 2 EMS 3 EMS EMS 1 interface to EMS boiler 1 EMS 4 interface to EMS boiler 4 If a second FM458/CMC 930 is installed, terminal on the r.h. (2nd) FM458/CMC 930 is assigned to boiler 5, terminal EMS 1 to boiler 6, terminal EMS 2 to boiler 7 EMS 3 and terminal EMS 4 to boiler 8. FM458/CMC 930 Strategy module (2011/06)

28 28 Installation 3.7 Assigning the boiler number The boilers are numbered consecutively starting from boiler 1. Boiler numbers are assigned as follows: for CAN boilers, by adjusting the CAN BUS address (address DIP switches) for EMS boilers, via connection to terminal EMS 1, EMS 2, EMS 3 or EMS 4 on the FM458/CMC 930 module. Important: the assignment of the boiler numbers must be unambiguous. Each boiler number may only be assigned once! USER INFORMATION The boiler sequence utilises the boiler number and is freely programmable via parameters (2011/06) FM458/CMC 930 Strategy module

29 Installation 29 Application 1: If only CAN boilers are installed, then the first CAN boiler will be equipped with the CFB 930 control unit with installed FM458/ CMC 930 module; this control unit is set to CAN address 1. The lag boilers receive the control unit CFB 910; these are numbered upwards with CAN addr. 2, 3 etc. Fig. 11 Multi-boiler system with CFB 930 control unit 1 CAN boiler 1 (Control unit with ECO-CAN bus address 1) 2 CAN boiler 2 (Control unit with ECO-CAN bus address 2) 3 CAN boiler 3 (Control unit with ECO-CAN bus address 3) FM458/CMC 930 Strategy module (2011/06)

30 30 Installation Application 2: If only EMS boilers are installed, use the CSM 920 control unit. This will be equipped with the FM458/CMC 930 module and set to CAN address 0/1. Boiler numbers are permanently assigned to the relevant boiler via terminals EMS 1, EMS 2, EMS or EMS 4 in the FM458/CMC 930 module. The boilers are consecutively numbered upwards. Fig. 12 Multi-boiler system with EMS control unit 1 EMS boiler 1 (at terminal EMS1) 2 EMS boiler 2 (at terminal EMS2) 3 Control unit CSM 920 (control unit with ECO-CAN BUS address 0/1) (2011/06) FM458/CMC 930 Strategy module

31 Installation 31 Application 3: If one or several CAN boiler(s) AND one or several EMS boiler(s) are installed, then the first CAN boiler will be equipped with the CFB 930 control unit with fitted FM458/CMC 930 module; this control unit is set to CAN address 1. The lag boilers will then be numbered upwards from 2, 3 etc. Fig. 13 Multi-boiler system with CFB 930 controller and EMS controller 1 CAN boiler 1 (Control unit with ECO-CAN bus address 1) 2 EMS boiler 2 (at terminal EMS2) 3 CAN boiler 3 (Control unit with ECO-CAN bus address 3) FM458/CMC 930 Strategy module (2011/06)

32 32 Installation 3.8 Recommended hydraulic schemes The recommended and displayed hydraulic schemes are tailored to the type of heat source, and show a selection of the schemes that are made possible by the FM458/CMC 930 function module. We differentiate between EMS and CAN boilers. EMS boilers are factory-fitted with the EMS control system. Floor standing EMS boilers are fitted with the MX10/MX15 control unit with BC15 programming unit; wall mounted boilers are equipped with the BC15 programming unit. CAN boilers must each be equipped with a CFB 910/930 control unit. Corresponding parameters are listed for each hydraulic scheme. DAMAGE TO THE SYSTEM CAUTION! The hydraulic schemes listed in this chapter are only illustrations of relative positions of the sensors, pumps and servomotors/ actuators that may be required. For the sake of clarity, some hydraulic components that may be required, such as overflow valves, expansion vessels etc., are not shown. Install the hydraulic components in accordance with current technology (2011/06) FM458/CMC 930 Strategy module

33 Installation 33 Designation Designation DV Motorised ring butterfly valve PS Cylinder primary pump EMS Energy Management System PZ DHW circulation pump FA Sensor outside temperature RK Boiler return FB Drinking water sensor RV line regulating valve FK Sensor boiler water temperature RWT Heat exchanger return FV Heating circuit flow sensor SH Heating circuit actuator FVS Strategy flow sensor SR Return servomotor HK Heat.circuit TWH Temperature limiter - underfloor heating circuit HB High temperature heating circuit VK Boiler flow LT Low temperature heating circuit VWT Heat exchanger flow PH CH circulation pump PK Boiler circulation pump Tab. 4 Abbreviations used in the hydraulic schemes FM458/CMC 930 Strategy module (2011/06)

34 34 Installation CAN boiler via low loss header 4-boiler system; boilers integrated via low loss header (pressureless distributor), heating circuits and DHW heating via primary pump (CB = condensing boiler, LTB = low-temperature boiler) Fig. 14 Hydraulic scheme 1 1 CAN boiler 1: e.g. condensing boiler 2 CAN boiler 2: e.g. low-temperature boiler 3 CAN boiler 3: e.g. low-temperature boiler 4 CAN boiler 4: e.g. low-temperature boiler 5 CFB 930 with FM441/CMM 910, FM442/CMM 920 and FM458/CMC CFB CFB CFB DHW cylinder (2011/06) FM458/CMC 930 Strategy module

35 Installation 35 No. Parameter Adjustments Description 1. Number of boilers 4 2. Maximum system temperature 75 C system-specific 3. Hydraulic decoupling yes 4. Sequence reversal (Chapter 7.5, page 72) No default system-specific 5. Load limit (Chapter 7.6, page 80) No default system-specific 6. Operating mode No default system-specific 7. Lead boiler run-on time (pump) 60 min. 8. Run-on time for follow-on boiler 5 min. Notes: The operating conditions are met and the lag boilers are hydraulically blocked via the boiler circuit (either via the boiler circuit pump and 3-way boiler circuit actuator or via the boiler circuit pump and check valve). DHW heating via FM441/CMM 910 function module. FM458/CMC 930 Strategy module (2011/06)

36 36 Installation EMS boiler via low loss header 4-boiler system with floorstanding condensing boilers; boilers connected via low loss header (hydraulic separator), heating zones and DHW heating via tank primary pump (BW boiler = condensing boiler, LT boiler = low temperature boiler) Fig. 15 Hydraulic scheme 2 1 EMS boiler 1: e.g. condensing boiler 2 EMS boiler 2: e.g. condensing boiler 3 EMS boiler 3: e.g. condensing boiler 4 EMS boiler 4: e.g. condensing boiler 5 CSM 920 with FM441/CMM 910, FM442/CMM 920 and FM458/CMC DHW cylinder 7 MX10/MX15 8 MX10/MX15 9 MX10/MX15 10 MX10/MX (2011/06) FM458/CMC 930 Strategy module

37 Installation 37 No. Parameter Adjustments Description 1. Number of boilers 4 2. Maximum system temperature 75 C system-specific 3. Hydraulic decoupling yes 4. Sequence reversal (Chapter 7.5, page 72) No default system-specific 5. Load limit (Chapter 7.6, page 80) No default system-specific 6. Operating mode No default system-specific 7. Lead boiler run-on time (pump) 60 min. 8. Run-on time for follow-on boiler 5 min. Notes: The operating conditions are met and the lag boilers are hydraulically blocked via the boiler circuit pump and check valve. DHW heating via FM441/CMM 910 function module. FM458/CMC 930 Strategy module (2011/06)

38 38 Installation EMS boiler with EMS DHW 4-boiler system with floorstanding condensing boilers; boilers connected via low loss header (hydraulic separator), heating circuits and DHW heating via tank primary pump of the EMS boiler 1 (BW boiler = condensing boiler). Fig. 16 Hydraulic scheme 3 1 EMS boiler 1: e.g. condensing boiler 2 EMS boiler 2: e.g. condensing boiler 3 EMS boiler 3: e.g. condensing boiler 4 EMS boiler 4: e.g. condensing boiler 5 CSM 920 with FM442/CMM 920 and FM458/CMC DHW cylinder (2011/06) FM458/CMC 930 Strategy module

39 Installation 39 No. Parameter Adjustments Description 1. Number of boilers 4 2. Maximum system temperature 75 C system-specific 3. Hydraulic decoupling yes 4. Sequence reversal (Chapter 7.5, page 72) No default system-specific 5. Load limit (Chapter 7.6, page 80) No default system-specific 6. Operating mode No default boiler-specific 7. Lead boiler run-on time (pump) 60 min. 8. Run-on time for follow-on boiler 5 min. Notes: DHW heating via diverter valve of EMS boiler 1 (see Chapter 8 "DHW data", page 88). Hydraulic blocking of the lag boiler via boiler circuit pump and check valve. FM458/CMC 930 Strategy module (2011/06)

40 40 Installation CAN boilers in series 2-boiler system; boilers integrated in series (pressure distributor), heating circuits and DHW heating via primary pump (CB = condensing boiler, LTB = low-temperature boiler) Fig. 17 Hydraulic scheme 4 1 CAN boiler 1: e.g. condensing boiler 2 CAN boiler 2: e.g. low-temperature boiler 3 CFB 930 with FM441/CMM 910, FM442/CMM 920 and FM458/CMC CFB DHW cylinder (2011/06) FM458/CMC 930 Strategy module

41 Installation 41 No. Parameter Adjustments Description 1. Number of boilers 2 2. Maximum system temperature 75 C system-specific 3. Hydraulic decoupling no 4. Sequence reversal (Chapter 7.5, page 72) None 5. Load limit (Chapter 7.6, page 80) No default system-specific 6. Operating mode No default system-specific 7. Lead boiler run-on time (pump) 60 min. 8. Run-on time for follow-on boiler 5 min. Notes: High efficiency through fixed boiler sequence with condensing boiler as lead boiler. The operating conditions are met and the lag boilers are hydraulically blocked via the boiler circuit (either via the boiler circuit pump and 3-way boiler circuit actuator or via the boiler circuit pump and check valve). DHW heating via FM441/CMM 910 function module. FM458/CMC 930 Strategy module (2011/06)

42 42 Installation CAN boilers in parallel 2-boiler system; boilers integrated in parallel (pressure distributor); heating circuits and DHW heating via primary pump. Fig. 18 Hydraulic scheme 5 1 external condensing flue gas heat exchanger (boiler 1) 2 CAN boiler 1: e.g. oil/gas boiler 3 CAN boiler 2: e.g. oil/gas boiler 4 CFB 930 with FM441/CMM 910, FM442/CMM 920 and FM458/CMC CFB DHW cylinder (2011/06) FM458/CMC 930 Strategy module

43 Installation 43 No. Parameter Adjustments Description 1. Number of boilers 2 2. Maximum system temperature 75 C system-specific 3. Hydraulic decoupling no 4. Sequence reversal (Chapter 7.5, page 72) No default system-specific 5. Load limit (Chapter 7.6, page 80) No default system-specific 6. Operating mode No default system-specific 7. Lead boiler run-on time (pump) 60 min. 8. Run-on time for follow-on boiler 5 min. Notes: Match the respective pressure drop on the boiler side through suitable measures, such as through sizing the pipework or balancing valves. Separate boiler circuit servomotors (motorised ring butterfly valves) for maintaining the operating temperatures plus for hydraulic blocking of lag boilers. Recommended load split of boilers: 50/50. Externally controlled heating circuit not recommended. DHW heating via FM441/CMM 910 function module. FM458/CMC 930 Strategy module (2011/06)

44 44 Installation CAN boilers in "Tichelmann System" 2-boiler system; boilers integrated according to "Tichelmann System" (pressure distributor), heating circuits and DHW heating via primary pump (LTB = low-temperature boiler) Fig. 19 Hydraulic scheme 6 1 CAN boiler 1: e.g. low-temperature boiler 2 CAN boiler 2: e.g. low-temperature boiler 3 CFB 930 with FM441/CMM 910, FM442/CMM 920 and FM458/CMC CFB DHW cylinder (2011/06) FM458/CMC 930 Strategy module

45 Installation 45 No. Parameter Adjustments Description 1. Number of boilers 2 2. Maximum system temperature 75 C system-specific 3. Hydraulic decoupling no 4. Sequence reversal (Chapter 7.5, page 72) No default system-specific 5. Load limit (Chapter 7.6, page 80) No default system-specific 6. Operating mode serial boiler-specific 7. Lead boiler run-on time (pump) 60 min. 8. Run-on time for follow-on boiler 5 min. information Only install boilers of the same type (same hydraulic pressure drop). Separate boiler circuit servomotors (motorised ring butterfly valves) for maintaining the operating temperatures plus for hydraulic blocking of lag boilers. Load split of boilers: 50/50 %. Externally regulated heating circuits are not recommended. DHW heating via FM441/CMM 910 function module. FM458/CMC 930 Strategy module (2011/06)

46 46 Installation Twin-block boiler according to the "Tichelmann principle" 2-boiler system; boilers connected according to the "Tichelmann principle" (hydraulic separator); operating conditions for the 2-block boilers are ensured by internal control panels HT 3101e, heating circuits and domestic hot water by the tank primary pump. Fig. 20 Hydraulic scheme 7 1 CAN boiler 1: e.g. oil/gas boiler 2 CAN boiler 2: e.g. oil/gas boiler 3 CFB 930 with FM441/CMM 910, FM442/CMM 920 and FM458/CMC CFB DHW cylinder (2011/06) FM458/CMC 930 Strategy module

47 Installation 47 No. Parameter Adjustments Description 1. Number of boilers 2 2. Maximum system temperature 75 C system-specific 3. Hydraulic decoupling no 4. Sequence reversal (Chapter 7.5, page 72) No default system-specific 5. Load limit (Chapter 7.6, page 80) No default system-specific 6. Operating mode No default system-specific 7. Lead boiler run-on time (pump) 60 min. 8. Run-on time for follow-on boiler 5 min. information Only install boilers of the same type (same hydraulic pressure drop). Internal boiler servomotors maintain the operating conditions and the hydraulic blocking of the lag boiler. Load split of boilers: 50/50 %. Externally regulated heating circuits are not recommended. DHW heating via FM441/CMM 910 function module. FM458/CMC 930 Strategy module (2011/06)

48 48 Installation Mixed cascade via low loss header 2-boiler system; boilers integrated via low loss header (pressureless distributor), heating circuits and DHW heating via primary pump (CB = condensing boiler, LTB = low-temperature boiler) Fig. 21 Hydraulic scheme 8 1 CAN boiler 1: e.g. low-temperature boiler 2 EMS boiler 2: e.g. condensing boiler 3 CFB 930 with FM441/CMM 910, FM442/CMM 920 and FM458/CMC MX10/MX15 5 DHW cylinder (2011/06) FM458/CMC 930 Strategy module

49 Installation 49 No. Parameter Adjustments Description 1. Number of boilers 2 2. Maximum system temperature 75 C system-specific 3. Hydraulic decoupling yes 4. Sequence reversal (Chapter 7.5, page 72) No default system-specific 5. Load limit (Chapter 7.6, page 80) No default system-specific 6. Operating mode No default system-specific 7. Lead boiler run-on time (pump) 60 min. 8. Run-on time for follow-on boiler 5 min. information The operating conditions are met and the lag boilers are hydraulically blocked via the boiler circuit (either via boiler circuit pump and 3-way boiler circuit actuator (only CAN boilers) or via boiler circuit pump and check valve (EMS and CAN boilers)). DHW heating via FM441/CMM 910 function module. FM458/CMC 930 Strategy module (2011/06)

50 50 Installation System with different EMS boilers 2-boiler system with floor standing and wall mounted boilers; boilers integrated via low loss header (pressureless distributor), heating circuits and DHW heating via primary pump (CB = condensing boiler) Fig. 22 Hydraulic scheme 9 1 EMS boiler 1: e.g. condensing boiler 2 EMS boiler 2: e.g. condensing boiler 3 MX10/MX15 4 CSM 920 with FM441/CMM 910, FM442/CMM 920 and FM458/CMC DHW cylinder (2011/06) FM458/CMC 930 Strategy module

51 Installation 51 No. Parameter Adjustments Description 1. Number of boilers 2 2. Maximum system temperature 75 C system-specific 3. Hydraulic decoupling yes 4. Sequence reversal (Chapter 7.5, page 72) No default system-specific 5. Load limit (Chapter 7.6, page 80) No default system-specific 6. Operating mode No default system-specific 7. Lead boiler run-on time (pump) 60 min. 8. Run-on time for follow-on boiler 5 min. information The operating conditions are met and the lag boilers are hydraulically blocked via the boiler circuit pump and check valve. DHW heating via FM441/CMM 910 function module. FM458/CMC 930 Strategy module (2011/06)

52 52 Integrating EMS boilers 4 Integrating EMS boilers 4.1 Base controller BC15 The BC15 base controller enables the standard operation of boilers with EMS/UBA 3x or EMS/burner control unit. For information regarding the operation of the BC15, see the service instructions for the EMS boiler. USER INFORMATION Further functions are set via the Programmer programming unit. Both rotary selectors of the BC15 base controller must be set to "Aut" (otherwise a fault message will be issued) (2011/06) FM458/CMC 930 Strategy module

53 Integrating EMS boilers Fig 23 Controls on the BC15 1 On/Off switch 2 Rotary selector for set DHW temperature 3 "DHW heating" LED 4 Status display 5 Rotary selector for maximum boiler water temperature in heating mode 6 "DHW demand" LED 7 "Burner" (On/Off) LED 8 Diagnostic plug 9 "Status display" key 10 "Flue gas test" key 11 "Reset" key (fault release button) FM458/CMC 930 Strategy module (2011/06)

54 54 Integrating EMS boilers Setting the output limit The boiler output can be restricted to 11 kw (or 50 kw with higher boiler output) using a jumper on the back of the base controller. Remove the base controller. Remove jumper ( Fig. 24[1]) if the boiler output is to be restricted. Jumper Status Explanation Not inserted Output restricted to 11 kw (50 kw) (only for boilers with UBA 3) Inserted Unrestricted output (delivered condition) 1 Fig 24 Back of the BC15 base controller 1 Jumper for restricting output (2011/06) FM458/CMC 930 Strategy module

55 Functions of the FM458/CMC Functions of the FM458/CMC 930 In the following sections, it is explained how to use the different functions and make settings via the Programmer programming unit. 5.1 Operation with Programmer SERVICE LEVEL GENERAL PARAM. Calling up the service level The respective service instructions of your control unit explain exactly how to use the Programmer programming unit. Here you will get a short overview of operating the Programmer. The Programmer has two operating levels available (level 1 with closed flap and level 2 with open flap) plus one service level (accessible via password). Various main menus are offered at the service level, giving access to sub-menus, where you can change the settings of the control units. 1 1 Display 2 Rotary selector 3 Function buttons 2 3 To reach the service level, press the following key combination (password), until "SERVICE LEVEL Gen. parameters" appears on the display. FM458/CMC 930 Strategy module (2011/06)

56 56 Functions of the FM458/CMC Integrating function module FM458/CMC 930 in the control unit Integrate function module FM458/CMC 930 on Programmer level After you have installed the FM458/CMC 930 function module ( see installation instructions "Modules for FB 9x0 control units"), your control unit will detect it automatically when it is switched on. USER INFORMATION If the function module FM458/CMC 930 is not automatically recognised, you must install it once manually via the Programmer programming unit Integrate function module FM458/CMC 930 manually on Programmer level Call up the service level. Turn the rotary selector until "SERVICE LEVEL Module selection" appears on the display. SERVICE LEVEL The display shows the main menu. Module selection Press "Display" to select the main menu "MODULE SELECTION". MODULE SELECTION Slot A The display shows "MODULE SELECTION Slot A". Boiler module ZM (2011/06) FM458/CMC 930 Strategy module

57 Functions of the FM458/CMC Turn the rotary selector to the position (slot) where the FM458/ CMC 930 function module is to be installed. The FM458/CMC 930 function module should be installed in e.g. slot 2. Hold down "Display" (the text in the lower line starts to flash) and turn rotary selector until the function module FM458/CMC 930 appears on the display. Release the display key". Press "Back". MODULE SELECTION slot 2 The function module FM458/CMC 930 ("strategy module") is installed on slot 2. Strategy module FM458 Press "Back" three times or close the operating flap to reach operating level 1. FM458/CMC 930 Strategy module (2011/06)

58 58 General specification data 6 General specification data V input As soon as a module with 0 10 V input has been fitted in the control unit, the following masks appear as listed in the table below: Module FM448/ CMB V FM456/ CMC 910 FM457/ CMC 920 FM458/ CMC 930 Name Fault message module KSE 2 (EMS) KSE 4 (EMS) Strategy module Temperaturebased control ZM433 Substation X X X X X Output-based control X (CM431 V6.xx or higher) X (CM431 V6.xx or higher) X (CM431 V8.xx or higher) Call up the service level. "GENERAL PARAM." appears as the first main menu. Press "Display" to call up a submenu (here: "Min. outdoor temperature"). The display shows the selected submenu. GENERAL PARAM. Min outside temp -10 C Turn the rotary selector until the submenu "0 10 V input" appears (2011/06) FM458/CMC 930 Strategy module

59 General specification data 59 + Hold down "Display" and turn the rotary selector until the required set value appears (here: "Temp control"). GENERAL PARAM. The display shows the set value. Release "Display" to save the entry V input Temp. control 0 10 V input Input range OFF Temp.control Output control Factory setting Temp. control FM458/CMC 930 Strategy module (2011/06)

60 60 General specification data 6.2 Temperature control 0 10 V input If you have selected "Temp. control" for a 0 10 V input, you can select the start and stop point, if required, for the external 0 10 V input. You can set the following: the set value in C for 0 V ("Temp. control 0V equates to") the set value in C for 10 V ("Temp. control 10V equates to") The following linear curve is calculated from these values: Fig 25 Input 0 10 V x Input voltage in V (factory setting) y Set boiler temperature in C The start value (start point) of the curve is set to 0.6 V for a positive curve, Fig. 25 shows the factory setting. Call up the service level. "GENERAL PARAM." appears as the first main menu. Press "Display" to call up a submenu (here: "Min. outdoor temperature") (2011/06) FM458/CMC 930 Strategy module

61 General specification data 61 The display shows the selected submenu. GENERAL PARAM. Min outside temp -10 C Turn the rotary selector until submenu "Temp. control equates to 0 V" or "Temp. control equates to 10 V" appears. + Hold down "Display" and turn the rotary selector until the required set value appears (here: "5 C"). The display shows the set value. GENERAL PARAM. Temp control Release "Display" to save the entry. 0 V equates to 5 C Press "Back" to return to the next level up. Turn the rotary selector until submenu "Temp. control equates to 10 V" appears. + Hold down "Display" and turn the rotary selector until the required set value appears (here: "90 C"). The display shows the set value. GENERAL PARAM. Temp control Release "Display" to save the entry. 10 V equates to 90 C FM458/CMC 930 Strategy module (2011/06)

62 62 General specification data Input range Factory setting Temperature control 0 V 5 C 99 C 5 C Temperature control 10 V 5 C 99 C 90 C USER INFORMATION If a curve with a negative incline is programmed, e.g. 0 volt = 90 C, ensure that all 0 10 volt inputs of a control unit are controlled. An open input corresponds to 0 V and thus to a heat demand of e.g. 90 C. The demand should be set parallel at all 0 10 V inputs of a control unit, if applicable. 6.3 Output control for 0 10 V input The 0 10 V input can also be used for output control. If you have selected output control for the 0 10 V input, you can, if required, match the curve for external output control. You can set the following: The set output value for 0 V ("Output control equates to 0V equates to") The set output value for 10 V ("Output control equates to 10V equates to") The following linear curve is calculated from these values: (2011/06) FM458/CMC 930 Strategy module

63 General specification data 63 Fig V input x Input voltage in V (factory setting) y Output demand in % The start value (start point) of the curve is set to 0.6 V with a positive curve. USER INFORMATION In case of external power control, the control units can no longer take internal heat demands, e.g. from heating zones or DHW function, into consideration. USER INFORMATION If a curve with a negative incline is programmed, e.g. 0 volt = 100 % output, ensure that all 0 10 volt inputs of this control unit are used. An open input corresponds to 0 V and thus to an output demand of 100 %. The demand should be set parallel at all 0 10 V inputs of a control unit, if applicable. FM458/CMC 930 Strategy module (2011/06)

64 64 General specification data Call up the service level. "GENERAL PARAM." appears as the first main menu. Turn the rotary selector until the main menu "BOILER PARAM." appears. Press "Display" to call up a submenu (here: "No. of boilers"). Turn the rotary selector until submenu "Output control" appears. BOILER PARAM. The display shows the selected submenu V input Output-based control + Hold down "Display" and turn the rotary selector until the required value appears (here: "0 V corresponds to 0%"). BOILER PARAM. Output-based control 0 V equates to 0% The selected value flashes on the display. Release "Display" to save the entry. Turn the rotary selector until the submenu "10 V equates to...%" appears. + Hold down "Display" and turn the rotary selector until the required value appears (here: "10 V corresponds to 100%") (2011/06) FM458/CMC 930 Strategy module

Service instructions. FM443 solar module. Function module. For contractors. Read carefully prior to commissioning or service

Service instructions. FM443 solar module. Function module. For contractors. Read carefully prior to commissioning or service Service instructions Function module FM443 solar module For contractors Read carefully prior to commissioning or service 6 720 615 516-03/2008 GB/IE Contents 1 Safety........................................

More information

Servicing instructions for heating contractors

Servicing instructions for heating contractors Servicing instructions for heating contractors Control unit 6 720 803 706-00.1T Logamatic 4323 Read carefully prior to installation and maintenance. 6 720 804 726 (2012/04) GB Table of contents Table of

More information

Logamatic 4000 Modular Control System Control Units and Extended Functions

Logamatic 4000 Modular Control System Control Units and Extended Functions Planning document Planning document Issue 05/2008 P I PI 4000 Modular Control System Control Units and Extended Functions Heat is our element 42 432 42 422 4322 422 2 with FM445 4323 MEC2 BFU remote control

More information

Operating instructions

Operating instructions Operating instructions Room controller 6 720 618 477-00.1RS Logamatic EMS RC35 programming unit For users Read carefully before use. 6 720 642 272 (10/2009) GB Overview of controls Overview of controls

More information

Installation and servicing instructions

Installation and servicing instructions Installation and servicing instructions Programming unit RC35 For qualified professionals Please read carefully prior to commissioning and servicing 7 747 006 341-12/2006 GB Contents Contents Contents

More information

Installation and service instructions

Installation and service instructions Installation and service instructions Programming unit Logamatic EMS RC25 programming unit For contractors Read carefully before installation and servicing. 6 720 642 759 (05/2010) GB Contents Contents

More information

Operating instructions

Operating instructions Operating instructions Control unit Logamatic 4211 For users Read carefully before use 7 747 016 927-03/2008 GB/IE Contents 1 Introduction................................................ 4 2 What you should

More information

Connecting cable. Installation instructions (2018/04) US

Connecting cable. Installation instructions (2018/04) US Connecting cable 7736504943 Installation instructions 6 720 882 320 (2018/04) US 2 Contents Contents 1 Explanation of symbols and safety instructions........................... 3 1.1 Guideline to symbols.............

More information

Operating instructions

Operating instructions Operating instructions Gas-fired condensing boiler Logano plus GB312 For the user Please read carefully before use 7 747 009 296-01/2007 EN Contents 1 For your safety..............................................

More information

Service Instructions for use by heating contractor

Service Instructions for use by heating contractor Service Instructions for use by heating contracr Please file in Service Binder Vitronic 300 Model KW3 Weather-responsive indoor/outdoor, digital boiler control for heating systems with one or more heating

More information

For heating engineer/user. Operating and Installation Manual VRC 630/2. Weather compensated cascade control VRC 630

For heating engineer/user. Operating and Installation Manual VRC 630/2. Weather compensated cascade control VRC 630 For heating engineer/user Operating and Installation Manual VRC 630/2 Weather compensated cascade control VRC 630 GB Contents Contents Overview 1 - Operation... 3 Overview 2 - Displays...4 Notes on the

More information

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE Installation instructions For the competent person Installation instructions VRT 350 VRT 350 GB, IE Legal information Document type: Product: VRT 350 Target group: Language: Installation instructions Authorised

More information

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

1 DOCUMENT REVISION CONTROL ELEMENTS... 9 CONTENTS Contents 1 DOCUMENT REVISION... 8 2 SOFTWARE VERSION... 8 3 BASIC DESCRIPTION... 8 4 CONTROL ELEMENTS... 9 4.1 BASIC DISPLAYS...10 4.2 CONTROL KEYS...11 4.2.1 Rotary button (Press / Turn)...11

More information

O CRC100. Comfort Room Controller (2015/01) en

O CRC100. Comfort Room Controller (2015/01) en 6 720 906 767-00.1O Comfort Room Controller 100 6 720 806 769 (2015/01) en 2 Contents Contents 1 Explanation of symbols and safety instructions..................... 3 1.1 Explanation of symbols.....................................

More information

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control For the owner and the heating engineer Operating and Installation Manual VRC 400 Programmable weather compensator with separat HW time control GB Contents Contents Notes on the documentation..... 4 Symbols

More information

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions Lago SD3 Differential Controller with Speed Control Operating and Installation Instructions Please observe the safety instructions and read through this manual carefully before commissioning the equipment.

More information

Installation instructions. Advanced Weather Compensation Controller. Sense II O UK/IE (2015/10)

Installation instructions. Advanced Weather Compensation Controller. Sense II O UK/IE (2015/10) Installation instructions Advanced Weather Compensation Controller Sense II 6 720 812 774-01.1O UK/IE 6 720 818 367 (2015/10) Contents Contents 1 Explanation of symbols and safety instructions.... 3 1.1

More information

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A... 70 80 99-00-O Residential Gas Condensing Boiler ZBR//8/35/4-3A... ZWB8/35/4-3A... 70 80 993 (03/03) CA/US Operating Instructions Contents Contents Key to symbols and safety instructions............................

More information

VR 90 Remote control unit

VR 90 Remote control unit For heating engineer/owner Operating and Installation Manual VR 90 Remote control unit Bus-modular control system GB VR 90 For the operator Operating manual VR 90 Remote control unit Bus modular control

More information

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25 Innovative heating controls NEW Commercial boiler control systems Control 8000 & MX25 2 Everything perfectly under control About the Bosch Group Leading global supplier The Bosch Group is active in the

More information

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO Great Britain en Installation, user and service manual Control panel HMI Gas 310/610 ECO PRO Dear Customer, Thank you very much for buying this appliance. Please read through the manual carefully before

More information

INSTRUCTION FOR THE USER THC V E OIL BLU

INSTRUCTION FOR THE USER THC V E OIL BLU INSTRUCTION FOR THE THC V E OIL BLU CONTENTS General safety information 4 Precautions 4 Control panel 5 Mode selection 8 User levels 10 Start-up 12 Temporary shutdown 15 Preparing for extended periods

More information

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE Installation instructions For the heating engineer Installation instructions timeswitch VTS 160 GB, IE Table of contents Table of contents 1 Notes on the installation instructions...4 1.1 Observing other

More information

Operating Instructions

Operating Instructions Operating Instructions Control panel Logamatic 4323 For the user Please read carefully before use 6 720 618 563-11/2008 US/CA Contents 1 Introduction................................................ 4 2

More information

VIESMANN. Installation instructions. Mixer extension kit. for contractors. Mixer extension kit. For one heating circuit with mixer

VIESMANN. Installation instructions. Mixer extension kit. for contractors. Mixer extension kit. For one heating circuit with mixer Installation instructions for contractors VIESMANN Mixer extension kit For one heating circuit with mixer Mixer extension kit 5/2017 Safety instructions Please follow these safety instructions closely

More information

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en 8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................

More information

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A... Residential Gas Condensing Boiler Greenstar combi 00 p / 5 p ZWB8-3A... ZWB4-3A... Operating Instructions 708733 (07/04) US/CA Contents Contents Explanation of symbols and safety instructions.......................

More information

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02) 6 720 612 481-00.1R Room temperature controller with solar control FR 120 Operating instructions for the user 2 Dear Customer, The controller is the cool head of your heating system. At the factory, we

More information

Operating instructions

Operating instructions Operating instructions Solar thermal controller 7747006071-00.1 SD Solar thermal system with Logamatic SC40 For the Owner Please read carefully before operation. 7 747 017 474 GB (2007/08) OSW Contents

More information

Operating instructions

Operating instructions Operating instructions Gas condensing boiler WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

More information

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER Heating Circuit ZONE Controller RVA 46.531/109 Zonal temperature controller for control of a lowtemperature heating system, for use with condensing gas boilers Instructions for the INSTALLER INDEX Page

More information

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15 INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15 01 CONTENTS Special information 2 General information 3 Safety 5 Appliance description, cleaning, care & maintenance 7 Appliance

More information

BM Programming Module. For the heating engineer Installation instructions

BM Programming Module. For the heating engineer Installation instructions For the heating engineer Installation instructions BM Programming Module WOLF GmbH Postfach 1380 84048 Mainburg Tel. 08751/74-0 www.wolf-heiztechnik.de Document no.: 3062612_201509 Subject to modifications

More information

Installation and operating instructions

Installation and operating instructions Installation and operating instructions Cascade module KM Wolf GmbH Postfach 1380 84048 Mainburg Tel. 08751/74-0 Fax 08751/741600 Internet: www.wolf-heiztechnik.de Part no. 30 62 449 Subject to modifications

More information

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data. ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data. The RVA63 controller can be utilized to control the following system configurations via LPB communication. Equipment Required

More information

O CRC200. Comfort Room Controller. Installation instructions for contractors (2015/02)

O CRC200. Comfort Room Controller. Installation instructions for contractors (2015/02) 6 720 811 153-00.1O Comfort Room Controller Installation instructions for contractors 6 720 811 156 (2015/02) 2 Contents Contents 11 Setup log (Service menu/contractor)............ 24 1 Explanation of

More information

Installation and Service Instructions SM1 SOLAR CONTROL MODULE IMPORTANT. Read and save these instructions for future reference.

Installation and Service Instructions SM1 SOLAR CONTROL MODULE IMPORTANT. Read and save these instructions for future reference. Installation and Service Instructions for use by heating contractor Solar Control Module for solar connections to the Vitotronic control SM1 SOLAR CONTROL MODULE Product may not be exactly as shown IMPORTANT

More information

UK arotherm Schematics and installation guide

UK arotherm Schematics and installation guide UK arotherm Schematics and installation guide Air to Water Heat Pumps (AWHP) Controls: VRC 700, VR 70, VR 91 The Vaillant heat pump booklet contains documentation to assist in the design, installation

More information

System Installation. multi-zone heating

System Installation. multi-zone heating System Installation multi-zone heating Table of contents INTRODUCTION 1 Instructions guidance... 2 1.1 Product documentation...2 1.2 Associated documents...2 1.3 Explanation of symbols...2 1.4 Guarantee

More information

/2010 US/CA

/2010 US/CA 6 720 646 148-11/2010 US/CA (en) For the user User s Instructions Condensing gas boiler Logamax plus GB162-L.B. 80 kw/100 kw Please read thoroughly before operating This manual is available in the English

More information

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O HMC300 Control unit EMS plus 6 720 808 471-00.1O Operating Instructions 6 720 813 192 (2014/10) Contents Contents Key to symbols and safety instructions................3 1.1 Key to symbols...........................

More information

Boiler controller S-Tronic Plus

Boiler controller S-Tronic Plus Operating Instructions Boiler controller S-Tronic Plus Version 50.0 - Build 05.0 Translation of the original German operating instructions for technicians and operators Read and follow the instructions

More information

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb. Edition 06.14 GB Operating and installation instructions Lago FB digital remote control Translation from the German 2014 Elster GmbH Safety Please read and keep in a safe place Please read through these

More information

Mixer module VR 61. Operating and Installation Manual. Mixer module for VRC 430 / VRC 430f

Mixer module VR 61. Operating and Installation Manual. Mixer module for VRC 430 / VRC 430f For the heating engineer/for the owner Operating and Installation Manual Mixer module VR 61 Mixer module for VRC 430 / VRC 430f VR 61 GB Contents Contents 1 Notes on the documentation 3 1.1 Storage of

More information

Quickheat 30 weather compensated boiler control

Quickheat 30 weather compensated boiler control Quickheat 0 weather compensated boiler control A compact and sophisticated heating controller The compact KM controller is designed for the control of fan assisted boilers with modulating burners. The

More information

Operating instructions

Operating instructions Operating instructions Control unit - CGL Zone 0.0 C Friday 3/0/08 : 6 Wolf GmbH Postfach 380 D-84048 Mainburg Tel. +49 (0)875/74-0 Fax +49 (0)875/74600 Internet: www.wolf-heiztechnik.de Document no.:

More information

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data. ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data. The RVA 46 Zone Controller can only be used in conjunction with a RVA47 controlled boiler installation. The RVA46 controller

More information

GREENSOURCE HYDROLIGHT AND HYDROCOMFORT

GREENSOURCE HYDROLIGHT AND HYDROCOMFORT USER INSTRUCTIONS AIR TO WATER SPLIT HEAT PUMP GREENSOURCE HYDROLIGHT AND HYDROCOMFORT OUTDOOR UNIT 7.5, 10, 11 AND 12, 1 PHASE AND 3 PHASE MODELS HYDROLIGHT 8 AND 16 1 PHASE HYDROCOMFORT 8 AND 16 1 PHASE

More information

Technical Data Manual

Technical Data Manual VITOTRONIC 300 Weather-responsive indoor/outdoor, digital boiler control for heating systems with one or more heating circuits Technical Data Manual Vitotronic 300 Model KW3, Part No. Z001 231 For operation

More information

Boiler controller Lambdatronic S 3200

Boiler controller Lambdatronic S 3200 Operating Instructions Boiler controller Lambdatronic S 3200 Version 50.04 - Build 05.04 Translation of the original German operating instructions for technicians and operators Read and follow the instructions

More information

D-TECT 3 IP. GJD260 IP Motion Detector

D-TECT 3 IP. GJD260 IP Motion Detector D-TECT 3 IP GJD260 IP Motion Detector PACKAGE CONTENTS 1 x D-TECT 3 IP 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare sliding curtains 2 x Tamper feet 1 x Tamper

More information

ir-range 8G /03.15 Changes reserved.

ir-range 8G /03.15 Changes reserved. U s e r m a n u a l ic-range is-range ir-range 8G.52.80.00/03.15 Changes reserved. Contents 1. Introduction...3 2. Safety...5 3. Boiler description...6 4. Display and functions...7 4.1 DHW and Heating

More information

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

Wall Hung Boiler Room Thermostat OR30 OT Thermostat 8 733 201 137-00.1O Wall Hung Boiler Room Thermostat OR30 OT Thermostat Operating Instruction 6 720 812 418 (2014/07) en 2 Contents Contents 1 Symbols and safety precautions..................................

More information

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Revision 6/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Revision 4/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

Control Application. Supplement - ACVMax

Control Application. Supplement - ACVMax prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Logic+ Combi

Logic+ Combi USER GUIDE Logic+ Combi 24 30 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use

More information

Operating instructions THETA control unit for heating contractors. ROTEX control unit: - THETA 23R - THETA RS - THETA HEM1

Operating instructions THETA control unit for heating contractors. ROTEX control unit: - THETA 23R - THETA RS - THETA HEM1 Operating instructions THETA control unit for heating contractors. ROTEX control unit: - THETA 23R - THETA RS - THETA HEM1 Introduction Introduction The ROTEX THETA control unit is a simple to operate

More information

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...

More information

Operating instructions

Operating instructions Operating instructions For the operator Operating instructions ecotec plus Gas-fired wall-hung high-efficiency boiler GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Telefon

More information

GHP AWO 38 Technical overview

GHP AWO 38 Technical overview Gas absorption heat pump 9 Technical overview single unit G&' &(')*ption heat pump components. 1 7 2 8 9 3 4 10 8 5 6 1 +),-.&/012 &0* ')-*34 5&1 2 G414*&/)* 3 G&' (-*ner 4 6)1,41'4* 5 6)7(-'/0)1 38&7(4*

More information

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB 6 720 648 662-00.1T UNI 7000 F Operating instructions For the user AU/G 2 Contents Contents Contents 2 1 Safety information and explanation of symbols 3 1.1 For your safety 3 1.2 Explanation of symbols

More information

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL The SF-10 Temperature Control () is an efficient boiler operator with a digital LCD display with backlight, a boiler pump output, and an alarm. The

More information

VIESMANN. Service instructions VITODENS 200-W. for contractors

VIESMANN. Service instructions VITODENS 200-W. for contractors Service instructions for contractors VIESMANN Vitodens 200-W Type WB2B, 4.8 to 35.0 kw Wall mounted gas fired condensing boiler Natural gas and LPG version For applicability, see the last page VITODENS

More information

STREBEL S-CB + Cascade Kits

STREBEL S-CB + Cascade Kits STREBEL S-CB + Cascade Kits Models + 60 - + 80 - + 100 - + 120 PX 120 - + 10 - + 180 Installation & Operating Manual 2x60 up to 12x180 Please read and understand before commencing installation and leave

More information

ProCon Boiler Controller Commissioning Quick Reference Guide

ProCon Boiler Controller Commissioning Quick Reference Guide ProCon Boiler Controller Commissioning Quick Reference Guide This sheet is intended as a quick reference guide and should be read in conjunction with the operating and maintenance manual for the boiler

More information

Original operating instructions Safety switch with guard locking AC901S AC902S

Original operating instructions Safety switch with guard locking AC901S AC902S Original operating instructions Safety switch with guard locking AC901S AC902S 7390914/03 01/2017 Contents 1 Preliminary note...4 1.1 Explanation of symbols...4 2 Safety instructions...4 3 Items supplied...5

More information

Intelligent cascading kit

Intelligent cascading kit Technical Service Instruction Intelligent cascading kit Kit components: Cascading cable (2X) 6720811759 / 238-51036-00A (2014/05) Table of contents Table of contents 1 Key to symbols and safety instructions............

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

BOSCH CONDENS 5000W ZSB18-2A

BOSCH CONDENS 5000W ZSB18-2A 6720646195-00.1Wo HYDRONIC GAS SYSTEM BOILER 18kW BOSCH CONDENS 5000W ZSB18-2A Installation and Servicing Instructions 10 Boiler information AU/NZ 1 2 3 4 5 15 6 14 7 8 6720644743-04.1Wo 13 12 11 10 9

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

APC BC300 Series 40kW 208/450/480V User Guide

APC BC300 Series 40kW 208/450/480V User Guide APC BC300 Series 40kW 208/450/480V User Guide Copyright 2002 APC Denmark ApS This manual is subject to change without notice and does not represent a commitment on the part of the vendor Thank You Thank

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd Product Data Sheet Mx-4000 Series User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels The operation and functions described in the manual are available from Software Versions

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

SCHMIDT LED Measured Value Display MD Instructions for Use

SCHMIDT LED Measured Value Display MD Instructions for Use SCHMIDT LED Measured Value Display MD 10.010 Instructions for Use Table of Contents 1 Important Information... 3 2 Application range... 4 3 Mounting instructions... 4 4 Electrical connection... 6 5 Signalizations...

More information

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book USER GUIDE IMAX XTRA EL 320-620kW For Installation Guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual. 1 MHG Heating Ltd ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual. Unit 4 Epsom Downs Metro Centre, Waterfield, Tadworth, Surrey, KT20 5LR Telephone 08456 448802 Fax 08456 448803

More information

Installation Instructions VITOTRONIC 300

Installation Instructions VITOTRONIC 300 Installation Instructions Vitotronic 300 Model KW3 Weather-responsive indoor/outdoor, digital boiler control for heating systems with one or more heating circuits Part No. Z001 231 VITOTRONIC 300 Certified

More information

prestige Control Application Supplement - ACVMax

prestige Control Application Supplement - ACVMax 2015-10 Prestige ACVMax Control Sup 12-14-15_ACVMax_Control 12/15/15 7:36 AM Page 1 prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory

More information

USER GUIDE LOGIC HEAT H

USER GUIDE LOGIC HEAT H USER GUIDE LOGIC HEAT H 12 15 18 24 30 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not

More information

For the operator/for the heating engineer. Operating and Installation Manual VRC 430. Weather compensator VRC 430

For the operator/for the heating engineer. Operating and Installation Manual VRC 430. Weather compensator VRC 430 For the operator/for the heating engineer Operating and Installation Manual VRC 430 Weather compensator GB VRC 430 For the operator Operating Manual VRC 430 Weather compensator VRC 430 Contents Appliance

More information

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit Operating instructions for the system user VIESMANN With constant temperature or weather-compensated control unit VITODENS 050-W 9/2014 Please keep safe. Safety instructions For your safety Please follow

More information

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER This manual must be left with owner and should be hung on or adjacent to the boiler for reference. US HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 APPENDIX A CONTROLLER

More information

MBZ300. Emergency power control unit. GB Installation instructions MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 PME PME. Reset.

MBZ300. Emergency power control unit. GB Installation instructions MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 PME PME. Reset. 24V 24V PME PME CM DM SM DM WM Reset Reset Emergency power control unit GB Installation instructions 1 Table of contents 1 Symbols and illustrations...3 2 Product liability...3 3 Safety instructions...3

More information

For the heating engineer. Installation manual. Interface 0-10V VR34

For the heating engineer. Installation manual. Interface 0-10V VR34 For the heating engineer Installation manual Interface 0-10V VR34 GB Contents Contents 1 Notes on the documentation...3 1.1 Storage of the documents...3 1.2 Symbols used...3 2 Safety instructions and regulations...4

More information

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION Environment IMPORTANT INFORMATION It is not anticipated that this equipment will be exposed to adverse environmental conditions without additional protection. Site the equipment in a frost free area. Ensure

More information

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

RVL471 Heating and Domestic Hot Water Controller Basic Documentation RVL471 Heating and Domestic Hot Water Controller Basic Documentation Edition: 2.2 Controller series: C CE1P2524E 23.10.2002 Siemens Building Technologies HVAC Products 2/118 HVAC Products 23.10.2002 Contents

More information

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

Modular Standard HP Chiller 1/4 screw compressor with Carel driver Program for pco¹ pco 2 and pcoc Modular Standard HP Chiller 1/4 screw compressor with Carel driver Manual version 1.0 25 September 2003 Program code: FLSTDmMSDE Do we want you to save you time and money?

More information

D-TECT 2 IP. GJD230 IP Motion Detector

D-TECT 2 IP. GJD230 IP Motion Detector D-TECT 2 IP GJD230 IP Motion Detector PACKAGE CONTENTS 1 x D-TECT 2 IP 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare sliding curtains 2 x Tamper feet 1 x Tamper

More information

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM OD (FOR EXTERNAL USE)

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM OD (FOR EXTERNAL USE) INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM OD (FOR EXTERNAL USE) Thank you for choosing a DOMUSA TEKNIK heating boiler. Within the product range offered by DOMUSA TEKNIK you have chosen BioClass

More information

Service Instructions. Logamax plus GB kw/100 kw. Condensing gas boiler. For the contractor

Service Instructions. Logamax plus GB kw/100 kw. Condensing gas boiler. For the contractor Service Instructions Condensing gas boiler WARNING! Improper installation, adjustment, alteration, service or maintenance can cause injury, loss of life or property damage. Refer to this manual. For assistance

More information

VIESMANN. Installation instructions. Extension EA1. Safety instructions. for contractors. Part no

VIESMANN. Installation instructions. Extension EA1. Safety instructions. for contractors. Part no Installation instructions for contractors VIESMNN Extension E1 Part no. 7429 151 Safety instructions Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

Operating instructions

Operating instructions MA00929301 09/2015 Operating instructions ED10429002 ESYLUX GmbH An der Strusbek 40 22926 Ahrensburg Germany info@esylux.com www.esylux.com 1 Table of contents 1 Using the manual 8 2 Safety instructions

More information

M116 / M450 USER AND MAINTENANCE MANUAL FOR MODULATING-CONTROL BOILER WITH GAS BURNER EQUIPPED FOR NATURAL GAS. Type : B23 ATLANTIC 2000

M116 / M450 USER AND MAINTENANCE MANUAL FOR MODULATING-CONTROL BOILER WITH GAS BURNER EQUIPPED FOR NATURAL GAS. Type : B23 ATLANTIC 2000 M SERIES M116 / M45 USER AND MAINTENANCE MANUAL FOR MODULATING-CONTROL BOILER WITH GAS BURNER EQUIPPED FOR NATURAL GAS Type : B23 Country BE CH ES FR GB IE IT LU NL PT Category I2E(R)B I2H I2H I2Esi I2H

More information

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller Mounting and Operating Instructions Electronics from SAMSON EB 5610 EN Firmware version 1.40 Edition December 2014 Controller

More information

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE - SOLARE TERMICO Installation and operating instructions Temperature difference controller 6 inputs, 3 outputs, integrated data logger for

More information

MURELLE EV HE 25/55-30/55

MURELLE EV HE 25/55-30/55 UK ENSURE THAT THESE INSTRUCTIONS ARE LEFT FOR THE USER AFTER COMPLETION OF THE BENCHMARK SECTION MURELLE EV HE 25/55-30/55 User instructions 199838 Please read the Important Notice within this guide regarding

More information