Operation Manual, Parts Directory and Price List

Size: px
Start display at page:

Download "Operation Manual, Parts Directory and Price List"

Transcription

1 Operation Manual, Parts Directory and Price List Vertical Door Coolers* A Family Company Manufacturing In The USA Since 969 Self-Contained Models - BB, BB36, BB60, BB8, BB08, ND5, ND7, ND9, FV, FV8, LP60, LP8, LP08, PT60, PT8, PT08, KC, KC8, KC5, KC7, KC8* Remote Models - BB, BB8, BB7, BB96, LP8, LP7, LP96, PT8, PT7, PT96 Dry Storage Models - DS, DS8, DS7, LPDS *See Page for Important Cooler Serial Number Information BB60-L-XSH(LR) FV-BS(L) BB7-R-N(LLR) shown with optional wood panel doors PT60-L-LLH(LR/RL) Glastender, Inc. 500 North Michigan Road Saginaw, MI Fax / Rev Glastender, Inc.

2 Service and Parts Cooler Serial Number Information... Terms and Conditions... 3 Warranty... Installation Introduction... 5 Utility Requirements and Connections... 5 Uncrating and Start-Up Instructions... 5 Operation... 5 Cleaning Instructions Floor Sealing Instructions... 6 BB Minimum Air Flow Clearance Diagram... 6 Cooler Installation Checklist... 7 Cooler Design Change... 8 Specifications Electrical and Refrigeration Specifications... 9 Wiring Diagrams Endwall Models... 0 Self-Contained Models... Remote Models... Remote Models with Solenoid Control... 3 Built-in Fluorescent Light Fixtures... 3 BB Self-contained and KC Models... Replacement Parts Compressor and Condenser Related Parts BB Self-Contained & KC... 5 BB LP60, LP8, LP08, and Non Endwall BB60, BB8, BB08, ND5, ND7, ND9, KC7, and KC BB36, BB60, ND5, and KC5 Endwall... 8 BB8, BB08, ND7, ND9, KC7, and KC8 Endwall... 9 KC PT60, PT8, PT08... FV and FV8... Evaporator and Related Parts Doors and Related Parts Shelving, Racks and Related Parts Refrigeration Compartment Covers Volt Electrical Parts Fax /

3 Cooler Serial Number Information BB & ND Self-Contained Cooler Serial Number Information This manual is specific to self-contained BB60, BB8, BB08, ND5, ND7, and ND9 coolers prior to the serial numbers and dates listed below. BB60R 3363F 0/6/09 BB60L 35F 03/03/09 BB8R 357F 03/0/09 BB8L 356F 03/0/09 BB08R 35F 03/0/09 BB08L 36F 0/7/09 ND5R 359F 03/09/09 ND5L 3559F 03//09 ND7R 3906F 0/08/09 ND7L 375F 03//09 ND9R 36F 0/09/09 ND9L 375F 06/0/09 FV Cooler Serial Number Information This manual is specific to self-contained FV coolers prior to the serial numbers and dates listed below. FV SN 33788F and excluding SN 3753F & SN 33F FV8 SN 33788F and excluding SN 3796F LP Self-Contained Cooler Serial Number Information This manual is specific to self-contained LP coolers prior to the serial numbers and dates listed below. LP60R SN 38786F LP60L SN 38783F LP8R SN 39050N LP8L SN 3877N LP08R SN 33070N LP08L SN 3906N PT Self-Contained Cooler Serial Number Information This manual is specific to self-contained PT coolers prior to 07 and serial number BB, ND, LP, PT Remote Cooler Serial Number Information This manual is specific to remote BB, BB8, BB7, BB96, ND0, ND60, ND80, LP8, LP7, LP96, PT8, PT7, and PT96 coolers prior to 07 and serial numbers 3699 & KC Cooler Serial Number Information This manual is specific to self-contained KC8 coolers with serial numbers beginning with 0 and prior to 07 and serial number Fax /

4 Terms and Conditions Prices: All prices are LIST. Applicable taxes will be added. Quotations: Unless otherwise stated, quotations are effective for 30 days only. Acceptance: All orders are subject to acceptance by Glastender, Inc. s headquarters in Saginaw, Michigan. Possession of the Product Directory and Price List is not an offer to sell. Shipments: F.O.B. factory in Saginaw, Michigan. Freight terms are Third Party or Collect if shipped directly to you. Prepay and Add to Invoice freight terms are available upon request. The approximate shipping weights of all products are listed with the prices. Partial shipments will be made unless otherwise specified by the customer. Surface freight classifications are: GT-/GT-30/GW Glasswashers - Class 75 GT-8 Glasswashers - Class 50 All Underbar Equipment - Class 75 Bar Die Orders Class 50 Portable Bars - Class 75 Remote refrigerators (i.e., no compressor) or dry storage back bar equipment - Class 75 Self-contained refrigeration equipment - Class 50 Ice Display Units (IDU and GDU) - Class 85 Lighted Liquor Displays - Class 85 Beer line chillers and beer towers (beverage dispensing equipment) - Class 9.5 Bottle Disintegration System - Class 50 Ice Cream Freezers - Class 77.5 All small items are evaluated to see the most cost effective means for shipment. Many small items ship via UPS or FedEx; however, when dimensional weight is excessive, LTL carriers are the most cost effective choice. Spare parts orders received before :00 PM EST can usually be shipped the same day. The order department is happy to assist with routing or shipping questions. Delivery: The majority of equipment is manufactured to order and typically ships within three to six weeks after complete order information is received by the factory. In-stock equipment typically ships within two to three days of the factory receiving complete order information. Returns: Items specified as Manufactured to Order are NOT returnable. A Return Authorization number must be issued by the factory in advance for any items that are returnable. The number MUST be noted on the outside of the returned package. Returns must be received within 90 days of the issue date. Shipping charges must be prepaid. A minimum 0% restocking charge will be applied to all authorized returns if received in new, unused condition in the original packaging. The above conditions apply to spare part returns, except spare part returns must be received within 30 days of original shipment for electronic or electrical parts or within 90 days for all other parts. Loss or Damage: For customer routed shipments, Glastender, Inc. is not responsible for any loss, damage, or delay of merchandise during shipment. Such transit claims must be filed with the carrier. Merchandise must be examined on arrival. If shortages occur, Glastender, Inc. must be notified in writing within five (5) days of delivery to honor any shortage claim. Glastender will assume responsibility for freight claims on Prepay and Add shipments but the customer must inspect freight and note any damage upon receipt. Failure to do so may result in losses at the customer s expense. Custom Orders: Custom orders must be paid in advance and are not subject to cancellation. Laminates: Some products include common, readily available plastic laminates of the customer s selection. There may be an additional charge if uncommon varieties are ordered. //7 Payment Terms: Cash should be included with all orders unless credit terms have been arranged. To establish credit, banking and trade references are required. A convenient credit application is available upon request. Payment via credit card is not our normal means of receiving payment. Visa and MasterCard will be accepted, but must be charged at the time of shipment. In addition, a payment via credit card for orders totaling more than $500 will incur a 3% convenience fee on the total transaction amount Fax /

5 Glastender, Inc. warrants all products to be free of defects in material and workmanship. One-year labor and parts warranty applies to all glasswashers, self-contained refrigeration models, and BDS model bottle disintegration units. In established areas, a start up is included with GT- and GT-30 model glasswashers. Warranty is effective for one year from the date of installation or up to 8 months from date of factory shipment, whichever occurs sooner. Glastender, Inc. will replace any part or assembly found defective under normal use and service. For warranty labor claims beyond 5 months from the date of factory shipment, proof of date of installation or occupancy must be provided. Authorization for labor must be obtained from Glastender within the warranty period and prior to the service being performed. Labor warranty applies to the United States and Canada only. Remote refrigeration models and beer line chillers include a one-year parts warranty only. There is no labor warranty on these products. Field replacement parts not covered under the original warranty include a 90-day part warranty from the date of installation. FOUR YEAR ADDITIONAL COMPRESSOR WARRANTY: Glastender will warrant to the original user the compressor for all selfcontained refrigeration models for an additional four years following the regular one-year warranty period. This plan applies to the compressor only. A completed warranty claim form MUST accompany all returned defective parts or assemblies. Upon request, a defective part or assembly must be returned to Glastender, Inc., Saginaw, Michigan, with all transportation and delivery charges prepaid. Warranty repairs or replacements will be shipped FOB factory in Saginaw, Michigan. Reimbursement for applicable freight charges covers ground service only. Glastender provides in-warranty repairs during a service company s regular working days and hours. There is no provision for payment of a premium rate during overtime hours. When warranty service is requested during other than normal working hours, the end user will be charged the premium portion of the overtime rate. The warranty covers substantiated travel expenses for up to hours / 00 miles round trip up to a maximum of $50. Any additional costs due to installations that require extra work, time, or travel to gain access for service are the sole responsibility of the equipment purchaser. Any exceptions to these travel and access limitations must be pre-approved by a factory representative. The warranty does not cover door gaskets, chemical tubing, pump squeeze tubing, and/or any equipment subjected to accidents, freight damage, alterations from the original design, improper power and/or plumbing hookups, improper chemical use, general misuse, or lack of routine required maintenance as determined by Glastender, Inc. Installation, normal control adjustments, general maintenance, correcting an installation error, or service calls that reveal the unit is functioning normally will not be reimbursed under warranty. Condenser coils on self-contained refrigeration products must be cleaned regularly. Failure to provide adequate air flow to a refrigeration unit will void the warranty. Glastender shall not be liable for loss of use, revenue, or profit, or for any other indirect, incidental, special, or consequential damage including, but not limited to, product spoilage or loss. This warranty is conditioned upon Glastender receiving notice of any defect subject to this warranty within sixty (60) days of its discovery by the end user or dealer. All products are warranted only for the initial place of installation. Removal of a product automatically terminates this warranty. Warranty Statement APPLICAE TO ALL PRODUCTS SOLD WITHIN THE UNITED STATES AND CANADA SECOND YEAR EXTENDED PARTS & LABOR WARRANTY: Glastender s one-year parts and labor warranty on self-contained refrigeration units, excluding beer line chillers, can be extended to two years with the purchase of a two year parts and labor warranty. Specify part number EWR ($50 net price) when ordering. EXPORT WARRANTY - One year parts only. EXCLUSION OF WARRANTIES EXCEPT AS PROVIDED ABOVE, GLASTENDER MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT. LIMITATION OF REMEDIES AND DAMAGES If Buyer makes a valid and timely claim as outlined above, Glastender s liability and Buyer s remedies under this agreement will be limited solely to labor charges authorized and/or replacement or credit, at Glastender s option, with respect to Products returned at Buyer s expense within thirty (30) days after warranty repair. GLASTENDER S LIABILITY WILL IN NO EVENT BE GREATER IN AMOUNT THAN THE PURCHASE PRICE OF THE RETURNED PRODUCTS. GLASTENDER WILL NOT BE LIAE UNDER ANY CIRCUMSTANCE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LABOR COSTS EXCEPT AS COVERED UNDER OUR WARRANTY, LOST PROFITS OR THE LOSS OF PERISHAE PRODUCTS RESULTING FROM THE USE OF OR INABILITY TO USE OUR PRODUCTS OR FROM OUR PRODUCTS INCORPORATION INTO OR BECOMING A COMPONENT OF ANY OTHER PRODUCT. NEITHER PARTY WILL HAVE ANY NEGLIGENCE OR OTHER TORT LIABILITY TO THE OTHER, OR TO ANY THIRD PARTY, ARISING FROM ANY BREACH OF THIS AGREEMENT. GOVERNING LAW - JURISDICTION The terms and conditions of an order are to be governed and construed according to the laws of the State of Michigan, without regard to conflict of laws principles. Buyer hereby consents to the jurisdiction and venue of the courts located in Saginaw County, Michigan. No representative, distributor, dealer, or any other person is authorized to modify this warranty. This warranty replaces all other written or verbal warranties. NOTE: Glastender, Inc. s policy of constant quality improvement means that prices, specifications, and policies are subject to change without notice. Questions regarding this warranty should be directed to Glastender s Warranty Administrator IMPORTANT!! Attention Service Companies Please review the important warranty information on this page. If you believe a service call should be covered by the factory, please call the factory for authorization between 8AM and 5PM EST, Monday through Friday Fax /

6 Installation Introduction This manual describes the operational features of Vertical Door Coolers. Please review this information before attempting installation and operation. Long term, trouble-free service will follow if good housekeeping and maintenance procedures are followed. Thank you for selecting Glastender, Inc. products. Utility Requirements and Connections Electrical: 5 Volt AC, Phase, 60 Hz. A separate 5 Amp circuit is recommended. A 6-foot grounded cord and plug is included with self-contained models. Plumbing: Self-contained Models: Automatic condensate evaporator is included. No drain connection required. Remote Models: An external drain connection is required. Use the ten foot length of /" ID by 5/8" OD plastic tubing provided to run the drain line for condensate. The tubing should exit through one of the 3/" side knock-out holes. Self-contained Keg Coolers: The drain pain drain is pre-plumbed at the factory to stub out below the compressor compartment. A field connection to an external drain must be made from that point. Uncrating and Start-Up Instructions All models are shipped in one carton. These steps should be followed:. If legs or casters are included, bolt them to the base with the bolts provided.. Unwrap power cord from base if included. 3. Position unit and level and/or seal as required (see page and 3).. The evaporator drain pan on remote models must be plumbed to an external drain. All units with draft beer must be plumbed to an external drain (except model KC which includes an internal plastic drain bottle). On selfcontained models with draft beer and a factory installed finished top, the beer tower drain pan is plumbed through the cabinet and stubs out in the 3" space below the compressor compartment. Connection to an external drain must be made from that point. 5. Place shelves in desired location. 6. Plug into 5 volt AC outlet if a power cord is included. Remote models require electrical connections to be made by an electrician or remote refrigeration contractor. 7. Load with bottles or cans and allow time for products to cool. 8. Your Glastender equipment is now ready for use. Operation The operating temperature range is 36 F ( C) to 0 F (5 C). Self-contained models include an automatic defrost system. The refrigerator will defrost every six hours for approximately 0 minutes. Endwall coolers will defrost every four hours for approximately 5 minutes. During the defrost, the fan inside the cooler will remain on and the refrigeration system will turn off Cleaning Instructions Cleaning is essential to sustaining the integrity of your equipment and preventing corrosion. ESTIMATED CLEANING TIME: 5 to 0 minutes per unit daily, 5 minutes quarterly FREQUENCY: Daily cleaning of exterior & door gaskets. Quarterly cleaning of interior, including shelves. Cleaning Instructions continued on page Fax /

7 Installation Cleaning Instructions continued from page 3 PROCEDURE:. A non-chlorine based cleaner or mild detergent and warm water applied with a soft cloth or sponge to all contact surfaces.. Immediately rinse off cleaning agent(s), using clean warm water, clean soft cloth or sponge. 3. Dry with a soft clean cloth, removing standing water as soon as possible. NOTES:. Never use hydrochloric acid, wire brushes, steel wool, scrapers, or chlorine based cleaners on stainless steel surfaces, since they will break down the passivity layer and allow corrosion to occur.. On stainless steel surfaces, you may use a soft bristle brush or Scotch-Brite pad for more stubborn stains. Always scrub with the direction of the grain. Follow with a thorough cleaning as described above. 3. Deposits from food preparation must be properly removed. Even hard water deposits will rust stainless steel, if not removed.. Repeated cleaning may dry up black-vinyl-clad steel (exterior) surfaces of the cooler. Armor All or similar product can bring back the shine. Apply the product to a cloth and then rub into the surface, rather than spraying it directly onto the black-vinyl-clad surface. 5. The cooler door gaskets are most often overlooked when cleaning. Failure to clean them regularly will lead to premature failure, since alcohol and moisture build-up breaks down the gasket material. Sealing Vertical Door Cooler to Floor To comply with NSF & health codes, the cooler base must be sealed to the floor using NSF listed sealant. Place a bead of sealant along outer edges of the base and remove excess with disposable towel. The floor sealing procedure does not apply to models that include legs or casters. COOLER DOOR MAGNETIC GASKET COOLER CABINET Side View of Cabinet FLOOR BEAD SEALANT " BASE BB Minimum Air Flow Clearance Diagram WARNING: COMPRESSOR FAILURE DUE TO RESTRICTION OR OCKAGE OF AIR FLOW WILL VOID WARRANTY. 7" COMPRESSOR COMPARTMENT 8" " 8" " /" MINIMUM CLEARANCE FOR AIR FLOW AIR FLOW 8 /" 0" SWING WILL CONTINUE IF NO CABINET TO IMPEDE Plan View EVAPORATOR HOUSING 80 SWING Fax /

8 Installation Attention Installer: WARNING!! Failure to level this cooler WILL VOID THE FACTORY WARRANTY. Doors will not close properly causing damage to hinges, handles, and/or gaskets which will adversely affect the refrigeration systems. COOLER WITH 6" LEGS COOLER WITHOUT LEGS Cooler Installation Checklist Is the unit evenly and solidly supported, either upon legs, or flat on the base; check for high spots? If the unit was designed for legs, are they attached? Is the unit level at the base, from end to end? Do the doors open and close freely, without touching any other part of the unit in travel? Are there open holes to the outside of the cabinet which are not plugged or insulated? Are there obstructions of any kind to air flow into or out of the condensing unit? Is product tubing or are other lines installed in such a manner to not allow shelf access? Special Instructions for Keg Coolers Before you begin:. Disassemble the tower into three parts, stiffener, skin, and top plate, top plate by unscrewing the top two screws.. Mount the column stiffener with provided four /"-0x-/" bolts. 3. Install insulation provided into the bottom of the column stiffener.. Place the column skin over the stiffener. Run the beer lines through the hole at the same time. 5. Install insulation provided into the top of the tower assembly. stiffener skin 6. Mount the column top plate to the column stiffener with the two #0-3x/" phillips flat head s/s machine screws provided. 7. Apply a bead of silicone sealant around the perimeter of the column. Use your finger to smooth out the bead. 8. Wash tapping device and faucet with detergent and water. Flush beer tapping device and faucet lines Fax /

9 Cooler Design Change Important Design Change Information In February 00, Glastender released new BB and ND self contained cooler designs with the evaporator housing moved into an area above the compressor compartment. The serial numbers for these units will be and above. As of September 006, KC5, KC7, and KC8 model keg coolers are being manufactured as endwall models. Due to special customer request some BB and ND self contained models may not have the endwall design. Please be sure to verify which cooler design type you are ordering parts for. The term endwall will be used throughout this document to denote parts used for coolers featuring this design. Standard cooler configuration with evaporator inside cooler area. Compressor compartment may be located left or right. Endwall cooler configuration (most BB and ND models manufactured after Feb. 00, most KC models manufactured after Sept. 006) with evaporator located in housing above the compressor compartment. Compressor compartment may be located left or right Fax /

10 Electrical and Refrigeration Specifications BB Self-contained & KC Manufactured //06 to 3//7 Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low.0 full load amps, /6 HP R3a 5.0 oz KC Manufactured Before //06 Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low.8 full load amps, /6 HP R3a 5.0 oz FV, FV8, and BB36 Self-contained Models Manufactured Before /0 Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low 5. full load amps, /5 HP R 3.5 oz. 85 BB Remote, BB8, BB7, BB96, LP8, LP7, LP96, PT8, PT7, PT96 Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low R n/a n/a n/a LP60, LP8, LP08 & Non-Endwall BB60, BB8, BB08, KC8, KC7, & KC8 Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low 8.8 full load amps, /3 HP R 3.5 oz. 85 PT60, PT8 Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low 8.8 full load amps, /3 HP R0a 9.0 oz. 85 PT08 Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low 8.8 full load amps, /3 HP R0a 0.0 oz. 85 BB36, BB60, ND5, KC5 Endwall Models Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low 7. full load amps, /3 HP R3a *.0 oz *.0 oz. charge Serial # F and after. 0.0 oz. charge prior to Serial # F. BB8, BB08, ND7, ND9, KC7, KC8 Endwall Models Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low 0. full load amps, /3 HP R0a 6.0 oz Fax /

11 Wiring Diagram for BB36, BB60, ND5, & KC5 Endwall Models WHITE LIGHT RECEPTICAL AUX. RECEPTICAL DEFROST TIMER WHITE ACK EVAPORATOR FAN 3 ACK LIGHT SWITCH UE WHITE UE UE MAIN POWER SUPPLY CORD ACK WHITE GREEN WHITE UE 5v AC 5amp CONDENSER FAN ACK ORANGE ACK WHITE OVERLOAD COMMON RUN START RELAY STARTER ACK ORANGE THERMOSTAT COMPRESSOR Wiring Diagram for Models BB8, BB08, ND7, ND9, KC7, & KC8 Endwall Models WHITE LIGHT RECEPTICAL AUX. RECEPTICAL DEFROST TIMER ACK WHITE EVAPORATOR FAN 3 ACK LIGHT SWITCH UE WHITE UE UE MAIN POWER SUPPLY CORD ACK WHITE GREEN WHITE UE 5v AC 5amp CONDENSER FAN ACK ORANGE ACK WHITE OVERLOAD COMMON RUN START RELAY STARTER ACK ORANGE THERMOSTAT COMPRESSOR Fax /

12 Wiring Diagram for Self-Contained LP60, LP8, LP08, PT60, PT8, PT08, & Non Endwall BB36, BB60, BB8, BB08, ND5, ND7, ND9, KC8, KC7, KC8* *NOTE: See page 7 for endwall BB, ND, and KC self-contained model wiring diagrams Evaporator Assembly Note: Some Units May Have Two Fans (Three Fans Shown) 3 5 B B W S B ITEM 3 DESCRIPTION EVAPORATOR FAN ADE EVAPORATOR FAN MOTOR LIGHT SWITCH B 3 B W S 5 B W CABINET LIGHT RECEPTACLE THERMOSTAT DEFROST TIMER OVERLOAD CAPACITOR COMPRESSOR B W 0 START RELAY 5 VOLT 5 AMP SERVICE RECOMMENDED O O CONDENSER FAN MOTOR CONDENSER FAN ADE 3 BALLAST TOMBSTONE 5 STARTER B W G G O LEGEND M B = Black = Blue W = White O = Orange G = Green W 6 B O G W B 7 8 G 9 S W C M ELECTRICAL RATINGS All wires are 6 Gauge M 0 Compressor Condenser Fan Motor Evaporator Fan Motor 5V 5V 5V 7.05 AMP.80 AMP.8 AMP(Each) CONDENSING UNIT Fax /

13 Wiring Diagram for Remote Coolers Including Models BB, BB8, BB7, BB96, LP8, LP7, LP96, PT8, PT7, PT96 Evaporator Assembly Note: Some Units May Have Two Fans (Three Fans Shown) 3 TO LIGHTS ITEM DESCRIPTION O O EVAPORATOR FAN ADE EVAPORATOR FAN MOTOR 3 LIGHT SWITCH THERMOSTAT 5 DEFROST TIMER G LEGEND 5V 5 O BK = Black = Blue W = White O = Orange G = Green R = Red Y = Yellow Y/ = Yellow w/blue stripe Y/R = Yellow w/red stripe M O NEUTRAL W ELECTRICAL RATINGS All wires are 6 Gauge C REMOTE CONDENSING UNIT Evaporator Fan Motor 5V.8 AMP(Each) O Fax /

14 Wiring Diagram for Remote Coolers with Solenoid for Installing More than One Unit on One Condensing Unit Evaporator Assembly Note: Some Units May Have Two Fans (Three Fans Shown) 3 TO LIGHTS ITEM DESCRIPTION O O EVAPORATOR FAN ADE EVAPORATOR FAN MOTOR 3 LIGHT SWITCH THERMOSTAT 5 DEFROST TIMER G 5V 5 O O S W LEGEND BK = Black = Blue W = White O = Orange G = Green R = Red Y = Yellow Y/ = Yellow w/blue stripe Y/R = Yellow w/red stripe M ELECTRICAL RATINGS All wires are 6 Gauge NEUTRAL W Evaporator Fan Motor 5V.8 AMP(Each) Wiring Diagram for Models After /5/00 with Fluorescent Light System FLOURESCENT LIGHT SYSTEM TWO LIGHT FLOURESCENT LIGHT SYSTEM ONE LIGHT BK 5V R BALLAST Y/ LIGHT R R 5V B BALLAST STARTER B R B LIGHT R W W W Y/R LIGHT Fax /

15 Wiring Diagram for BB Self-contained & KC 3/5/7 and After 0 VOLTS POWER CORD G M R C OL THERMOSTAT START RELAY S S COMPRESSOR OVERLOAD CONDENSER FAN MOTOR EVAPORATOR FAN MOTOR ALL WIRE 6GA. TOTAL. AMPS 0 VOLTS POWER CORD G W FAN TOWER COOLING MOTOR O M R C OL THERMOSTAT S START RELAY S COMPRESSOR OVERLOAD ELECTRICAL RATINGS COMPRESSOR,.7 AMPS ALL WIRE 6GA. W W W W M BB/KC WIRE DIAGRAM LI N ACK FAN ORANGE POWER TIMER RED - FAN ACK - Wiring Diagram for BB Selfcontained & KC //06 to 3//7 KC Before //06 Wiring Diagram Fax /

16 BB Self-contained & KC Compressor, Condenser and Related Parts Part No. Old Part No. Description Price /0 HP Embraco compressor, R3a $ Start capacitor for /0 HP Embraco compressor GT-030 Relay for /6 HP Aspera R3a compressor Relay for /0 HP Embraco compressor GT-0300 Overload protector for /6 HP Aspera R3a compressor Overload protector for /0 HP Embroac compressor GT Automatic defrost timer Condenser fan motor GT-0380 Condenser fan motor blade GT-0335 Beer tower cooling fan shroud (KC models 05/0-0//06) GT-0358 Beer Tower Cooling Fan Motor (KC models 05/0-0//06) GT Exterior blade assembly (KC models 05/0-0//06) GT-0380 Interior blade assembly (KC models 05/0-0//06) GT-0353 Condenser fan motor mounting bracket GT Condenser coil (7" L, 6-7/8" H, -/" W) GT-036 Static condenser coil (KC before 0//06) Filter dryer with service port GT Condensate pan Wicking material Wicking Material (KC before 0//06) GT Cap tube 96" X GT-0330 Thermostat with knob and plate [Selco] GT-0389 Knob only Fax /

17 Standard BB36 Compressor and Condenser Related Parts Part No. Old Part No. Description Price GT /5 HP Aspera compressor, R $ GT-030 Start capacitor for /5 HP Aspera R compressor GT-0307 Relay for /5 HP Aspera R compressor GT-030 Overload protector for /5 HP Aspera R compressor GT /5 HP Tecumseh compressor, R (after /00) GT-03 Start capacitor for /5 HP Tecumseh R compressor GT-037 Relay for /5 HP Tecumseh R compressor GT-03 Overload protector for /5 HP Tecumseh R compressor GT Condenser fan motor, 6W GT-0380 Condenser fan motor blade assembly GT-0355 Condenser fan motor mounting bracket GT-0360 Condenser coil (0"L x 7-5/6"W x D) GT Fan shroud, condenser Filter dryer with service port GT Condensate pan (3-3/"L x 9-/"W x "D) GT-0380 Wicking material ( required) Elbow, white nylon, /" x /" GT-0376 Tubing, drain, clear plastic, /" ID x 5/8" OD, per foot GT-0353 Base, condensing unit GT Automatic defrost timer, 6hr GT-0300 Condensing unit power cord GT-0377 Cap tube 60" X Accumulator, suction line Fax /

18 Compressor and Condenser Related Parts for LP60, LP8, LP08, & Non Endwall BB60, BB8, BB08, ND5, ND7, ND9, KC7, and KC8 Part No. Old Part No. Description Price GT /3 HP Aspera compressor, R $ GT-030 Start capacitor for /3 Aspera HP R compressor GT-0303 Relay for /3 HP Aspera R compressor GT-030 Overload protector for /3 HP Aspera R compressor GT /3 HP Tecumseh compressor, R (after /00) GT-0306 Start capacitor for /3 HP Tecumseh R compressor GT-03 Relay for /3 HP Tecumseh R compressor GT-0307 Overload protector for /3 HP Tecumseh R compressor GT Condenser fan motor GT-0380 Condenser fan motor blade assembly GT-0355 Condenser fan motor mounting bracket GT-0360 Condenser coil (0"L x 7-5/6"W x "D) GT Fan shroud, condenser Filter dryer with service port GT Condensate pan (3-3/"L x 9-/"W x "D) GT-0380 Wicking material ( required) Elbow, white nylon, /" x /" GT-0376 Tubing, drain, clear plastic, /" ID x 5/8" OD, per foot GT-0353 Base, condensing unit GT Automatic defrost timer, 6hr GT-0300 Condensing unit power cord GT-0350 Cap tube 0" X Accumulator, suction line /3 HP, R (BB60, BB8, BB08, ND5, ND7, LP60, LP8, LP08, KC7, KC8) Fax /

19 BB36, BB60, ND5, & KC5* Compressor and Condenser Related Parts for Endwall Models Part No. Old Part No. Description Price GT-0350 /3 HP Tecumseh compressor, R3a $ GT-030 Start capacitor for /3 HP Tecumseh R3a compressor GT-03 Relay for /3 HP Tecumseh R3a compressor GT-03 Overload protector for /3 HP Tecumseh R3a compressor GT-035 Condenser fan motor GT-0380 Condenser fan blade assembly GT-035 Condenser fan motor mounting bracket GT-0360 Condenser coil GT Fan shroud, condenser Filter dryer with service port Condensate pan Wicking material GT-0373 Tubing, drain, clear plastic, per foot, 3/" ID GT Base, condensing unit GT Automatic defrost timer hr GT-0300 Condensing unit power cord GT Capillary tubing 8" X 0.036" (prior to Serial # F) Capillary tubing 65" X 0.09" (Serial # F and after) Accumulator, suction line * KC5 production began with serial number N Fax /

20 BB8, BB08, ND7, ND9, KC7*, & KC8* Compressor and Condenser Related Parts for Endwall Models Part No. Old Part No. Description Price GT /3 HP Embraco compressor, R0a $ GT-0303 Start capacitor for /3 HP Embraco R0a compressor GT-0303 Relay for /3 HP Embraco R0a compressor GT-0305 Overload protector for /3 HP Embraco R0a compressor GT Condenser fan motor GT-0380 Condenser fan blade assembly GT-035 Condenser fan motor mounting bracket GT-0369 Condenser coil GT Fan shroud, condenser Filter dryer with service port Condensate pan Wicking material GT-0373 Tubing, drain, clear plastic, 3/" dia, per foot GT Base, condensing unit GT Automatic defrost timer hr GT-0300 Condensing unit power cord GT-0380 Cap tube 8" x Accumulator, suction line *KC7 Endwall configuration production began with serial number N. *KC8 Endwall configuration production began with serial number 00309N Fax /

21 Compressor and Condenser Related Parts for KC8 Part No. Old Part No. Description Price GT /3 HP Aspera compressor, R $ GT-030 Start capacitor for /3 HP Aspera R compressor GT-0303 Relay for /3 HP Aspera R compressor GT-030 Overload protector for /3 HP Aspera R compressor GT /3 HP Tecumseh compressor, R (same models, after /00) GT-0306 Start capacitor for /3 HP Tecumseh R compressor GT-03 Relay for /3 HP Tecumseh R compressor GT-0307 Overload protector for /3 HP Tecumseh R compressor GT Condenser fan motor, 6W GT Condenser fan blade Condenser fan motor mounting bracket GT-0368 Condenser coil (9"L x 7"W x 3-/"D) Fan shroud, condenser (prior to 9/6/06) Housing, condenser fan, 8" models (after 9/6/06) Bracket, condenser fan, top, 8" models (after 9/6/06) Bracket, condenser fan, bottom, 8" models (after 9/6/06) Filter dryer with service port GT-0380 Condensate pan (7-7/8"L x 7-/"W x -/"D) Wicking material Elbow, white nylon, /" x /" GT-0376 Tubing, drain, clear plastic, /" ID x 5/8" OD, per foot GT Automatic defrost timer 6hr GT-0300 Condensing unit power cord GT-0350 Cap tube 0" X Accumulator, suction line Fax /

22 Compressor and Condenser Related Parts for PT60, PT8, and PT08 Part No. Old Part No. Description Price GT /3 HP Aspera compressor, R0a $ GT-0303 Start capacitor for /3 HP Aspera R0a compressor GT-035 Relay for /3 HP Aspera R0a compressor GT-0305 Overload protector for /3 HP Aspera R0a compressor GT /3 HP Tecumseh compressor, R0a (after /00) GT-0306 Start capacitor for /3 HP R0a Tecumseh compressor GT-03 Relay for /3 HP R0a Tecumseh compressor GT-0307 Overload protector for /3 HP R0a Tecumseh compressor GT Condenser fan motor GT-0380 Condenser fan motor blade assembly GT-035 Condenser fan motor mounting bracket GT-0360 Condenser coil (0"L x 7-5/6"W x "D) GT Fan shroud, condenser Filter dryer with service port GT Condensate pan (3-3/"L x 9-/"W x "D) GT-0380 Wicking material ( required) Elbow, white nylon, /" x /" GT-0376 Tubing, drain, clear plastic, /" ID x 5/8" OD, per foot GT-0353 Base, condensing unit GT Automatic defrost timer 6hr GT-0300 Condensing unit power cord GT-0350 Cap tube 0" X Accumulator, suction line /3 HP, R0A (PT60, PT8 and PT08) Fax /

23 Compressor and Condenser Related Parts for FV and FV8 Part No. Description Price /5 HP Aspera compressor, R (before 0/00) $ /5 HP Tecumseh compressor, R (after 0/00 and before 0/0/0) Compressor, /hp, 0V, Tecumseh model AEA30YXA (after 0/0/0) Start capacitor for /5HP Aspera R compressor (before 0/00) Start Capacitor, compressor, /hp 3a & /5hp R, 0V 5.00 Tecumseh model AEA30YXA (after 0/00) Relay for /5 HP Aspera R compressor (before 0/00) Relay, compressor, /hp R3a & /5hp R (after 0/00) Overload protector for /5 HP Aspera R compressor (before 0/00) Overload protector, /hp 3a & /5hp R, 0V, Compressor, model 5.00 AEA30YXA & AEA95EXA (after 0/00) Fan shroud, condenser Condenser fan motor, 6W Condenser fan motor blade Condenser fan motor mounting bracket Condenser coil (3"L x 8-/"W x -/"D) Filter dryer with service port Condensate pan (7"L x 3-7/8"W x -/"D), FV Wicking material ( required for the FV8) Condensate pan, FV Elbow, white nylon, /" x /" Tubing, drain, clear plastic, /" ID x 5/8" OD, per foot Automatic defrost timer 6hr Condensing unit power cord Cap tube 60" X.036" (before 0/0/0) Cap tube.09", per foot, 0" required (after 0/0/0) Accumulator, suction line Fax /

24 Evaporators and Related Parts Part No. Old Part No. Description Price GT-0330 Expansion valve, remote model, R refrigerant $ GT Expansion valve, remote model, R3a refrigerant GT-033 Expansion valve, remote model, R0a refrigerant GT-0350 Filter dryer for remote coolers GT-0330 Thermostat with knob and plate [Selco] GT-0389 Knob only GT Rope lighting, replacement kit, for BB, BB GT Rope lighting, replacement kit, for BB60, ND8, ND5, LPT GT Rope lighting, replacement kit, for BB8, ND GT Rope lighting, replacement kit, for BB GT Light, fluorescent, plug-in GT Switch (prior to 9/0) GT-033 Switch GT Electrical Outlet, black (Triboro with no ground) GT Receptacle, snap in with ground GT-0308 Solenoid valve, remote cooler GT-0309 Solenoid Coil, 0V, remote cooler GT-0380 Thermometer GT-0395 Light bulb cover. clear plastic Light socket with wire lead, set of GT-0396 Light bulb, GE# F6T GT-0397 Ballast for one light evaporator housing Kit, fluorescent light conversion, replaces single ballast for dual light systems GT-0398 Ballast for two light evaporator housing GT-039 Starter base, fluorescent light GT-039 Starter, fluorescent light, -6-8 watt GT Light bulb, fluorescent, 36" long, T (prior to 08-07) GT-0397 Ballast, 0V, lamp, rapid start (use with ) Bulb, Fluorescent 36", 5W T8 (after 08-07) Ballast, 3W T8 (use with 00036) Lamp holder, Fluorescent light, set of Fax /

25 Evaporators and Related Parts Blower Motor Assembly Endwall BB8, BB08, ND7, ND9, KC5, KC7*, KC8 *KC7 Note: Prior to SN 0373N Mf d Evaporator Coil for BB Self-contained, KC (8" L, -/8" H, 3-/" W) Evaporator Fan Replacement Parts Endwall BB36, BB60, ND5, All Non Endwall Models, and 6 KC7 SN 0373N Mf d --03 and later Evaporator Drain Pan, Left, for Endwall Models BB36, BB60, BB8, BB08, ND5, ND7, ND9, KC5, KC7, and KC8 (9-/8" L, 5" H, /" W) Evaporator Coil for Endwall Models BB36, BB60, BB8, BB08, ND5, ND7, ND9, KC5, KC7, KC8 (6" L, 6" H, " W) Drain Pan for BB Self-contained, KC (8-/" L, 3-7/8" H, " W) Drain Pan Assembly for Non Endwall Models BB8, BB60, BB7, BB8, ND5, ND7, KC8, KC7, KC8 (8-5/8" L, -5/8" H, 3/" W) Evaporator Coil for BB Remote, BB36, LP8, LP60, PT8, FV, FV8 (8-3/" L, -5/8" H, " W) Evaporator Coil for LP7, LP8, LP96, LP08, PT7, PT8, PT96, PT08 (39-/" L, -5/8" H, " W) Drain Pan for BB96, BB08 (39-/" L, -5/8" H, 3/" W) Drain Pan for PT8 (0-3/8" L, -3/" H, " W) Evaporator Coil for Non Endwall Models BB8, BB60, BB7, BB8, ND8, ND0, ND5, ND60 ND7, KC8, KC7, KC8 (7-/" L, " H, -7/8" W) Evaporator Coil for BB96, BB08, ND80 (38-/" L, " H, -7/8" W) Drain Pan for PT7, PT8, PT96, PT08 (-/8" L, -3/" H, " W) Drain Pan for BB Remote, BB36, LP8, LP60 (0-3/8" L, -3/" H, " W) Drain Pan for LP7, LP8, LP96, LP08 (-/8" L, -3/" H, " W) Fax /

26 Evaporators and Related Parts Part No. Old Part No. Description Price GT-0359 Blower motor assembly (Endwall BB8, BB08, ND7, ND9, $5.00 KC5, KC7, KC8) GT-0330 Evaporator fan guard (Endwall BB36, BB60, ND5 & All Non Endwall Models) GT-0380 Evaporator fan motor blade, white plastic (All Non Endwall Models) GT Evaporator fan motor (Endwall BB36, BB60, ND5 & All Non Endwall Models) GT-035 Evaporator fan motor mounting bracket (Endwall BB36, BB60, ND5.00 & All Non Endwall Models) Evaporator fan (BB and KC 3/5/7 and after) Evaporator fan motor (BB and KC prior to 3/5/7) GT Evaporator coil (BB Self-contained, KC) Evaporator coil (Endwall Models BB36, BB60, BB8, BB08, 0.00 ND5, ND7, ND9, KC5, KC7, KC8) (after 3/06) Evaporator coil replacement kit (BB36, BB60, BB8, 0.00 BB08, ND5, ND7, ND9 Endwall Models) (prior to 3/06) It is also necessary to purchase a drain pan, or GT-036 Evaporator coil (BB Remote, BB36, LP8, LP60, PT8, FV, FV8) GT-0368 Evaporator coil (PT60) GT-0363 Evaporator coil (LP7, LP8, LP96, LP08, PT8, PT96, PT08) GT Evaporator coil (Non Endwall Models, BB8, BB60, BB7, BB8, ND0, ND8, ND5, ND60 ND7, KC8, KC7, KC8) GT-0360 Evaporator coil (BB96, BB08, ND80) TXV valve extension Cover (3 door remote coolers) TXV valve extension Cover ( door remote coolers) TXV valve Cover (all remote coolers) GT Evaporator drain pan (BB Self-contained, KC) Evaporator drain pan (KC) (prior to 0//06) Evaporator drain pan, Right (Endwall Models BB36, BB60, BB8, BB08, ND5, ND7, ND9, KC5, KC7, KC8) (after 3/06) Evaporator drain pan, Left (Endwall Models BB36, BB60, BB8, BB08, ND5, ND7, ND9, KC5, KC7, KC8) (after 3/06) GT Evaporator drain pan (Endwall Models BB36, BB60, BB8, BB08, ND5, ND7, ND9) (prior to 3/06) Drain pan assembly, evaporator, fan, remote (Non Endwall Models, 5.00 BB8, BB60, BB7, BB8, ND5, ND7, KC8, KC7, KC8) Evaporator drain pan (BB96, BB08) Evaporator drain pan (PT60) Evaporator drain pan (PT8) GT Evaporator drain pan (PT7, PT8, PT96, PT08) GT Evaporator drain pan (BB Remote, BB36, LP8, LP60) GT Evaporator drain pan (LP7, LP8, LP96, LP08) Evaporator drain pan (FV, FV8) Assembly, shroud, evaporator, -fan, - door e/w, 0 Volt Assembly, shroud, evaporator, -fan, - door e/w, 0 Volt, digital t-stat Power supply for LED light strip LED light strip - lights Fax /

27 Doors and Related Parts Part No. Old Part No. Description Price GT-0350 Door handle, stainless $ GT-0350 Door handle, brass Door handle, tab style, glass door, right (Prior to 003) Door handle, tab style, glass door, left (Prior to 003) GT Door lock, stainless Key, #806, for stainless cooler door lock ( ) GT Door lock, brass Key, #606, for brass cooler door lock ( ) GT Plug for door handle, stainless GT Plug for door handle, brass GT Screws for top of handle, stainless (set of ), 0/3 x " PFH Machine Screw GT Screws for top of handle, brass (set of ), 0/3 x 5/8" PFH Machine Screw GT Screw for bottom of handle, stainless, and screws for old style brackets GT Screw for bottom of handle, black GT-03 Hinge set, 0º swing, set of two w/screws and washers GT-030 Hinge set, 80º swing, set of two (prior to /99 - w/ screws and washers) GT-035 Hinge bracket, bottom, left (prior to /99 - w/ screws) GT-036 Hinge bracket, bottom, right (prior to /99 - w/ screws) GT-030 Hinge set and brackets, 80º swing, left (complete with screws) GT-03 Hinge set and brackets, 80º swing, right (complete with screws) GT-0353 Lock bracket GT-0330 Hinge set & brackets for wood doors, 80º swing, left (complete with screws) GT-033 Hinge set & brackets for wood doors, 80º swing, right (complete with screws) GT-0335 Lock bracket for wood doors GT Cooler door gasket, push-in style, black, 3-/" x 3-/" OD GT Cooler door gasket, screw-on style (wooden doors before 6/9/90) 3½" x 3½" OD GT-0337 Cooler door gasket, LP and FV models, black, 3½" x 6½" OD GT-0333 Cooler door gasket, narrow door, black, 9½" x 3½" OD GT Screw for door hinges ( required) GT Bolts for brackets (6 required) Hinge rail, bottom, front vent coolers ( washers required, not 0.00 included) GT-0360 Plastic washer for hinge GT Bushing for hinge (gray) Standard laminated door trim rail kit Laminated door trim rail kit, for narrow doors Laminated door trim rail kit, for low profile narrow doors Laminated door trim rail kit, for low profile doors Fax /

28 Doors and Related Parts Replacement Doors for Units Manufactured PRIOR to January 999 Replacement Doors for BB, PT, RF, DS, KC7, and KC8 Models Part No. Old Part No. Description Price GT Black vinyl clad door (prior to /99) $ GT Unlaminated door (prior to /99) GT Laminated door (prior to /99) GT Stainless door (prior to /99) Glass door, black (prior to /99) Glass door, stainless (prior to /99) Replacement Doors for LP and FV Models GT Black vinyl clad door, low profile (prior to /99) GT Unlaminated door, low profile (prior to /99) GT Laminated door, low profile (prior to /99) GT Stainless door, low profile (prior to /99) Glass door, low profile, black (prior to /99) Glass door, low profile, stainless (prior to /99) Replacement Doors for ND Models GT Black vinyl clad door, narrow (prior to /99) GT-0367 Unlaminated door, narrow (prior to /99) GT Laminated door, narrow (prior to /99) GT Stainless door, narrow (prior to /99) Glass door, narrow, black (prior to /99) Glass door, narrow, stainless (prior to /99) NOTE: Door gaskets, handles and hinges are sold separately, see page 6 for part numbers Fax /

29 Doors and Related Parts Replacement Doors for Units Manufactured January 999 and After Replacement Doors for BB, PT, RF, DS, and KC Models Part No. Old Part No. Description Price GT Black vinyl clad door $ GT-0368 Unlaminated door GT-0368 Laminated door GT Stainless door Glass door, black Glass door, stainless Door, laminated, left hinge, BB/KC (March 5, 07 and after) Door, laminated, right hinge, BB/KC (March 5, 07 and after) Door, unlaminated, left hinge, BB/KC (March 5, 07 and after) Door, unlaminated, right hinge, BB/KC (March 5, 07 and after) Replacement Doors for LP and FV Models GT Black vinyl clad door, low profile GT Unlaminated door, low profile GT Laminated door, low profile GT Stainless door, low profile Glass door, low profile, black Glass door, low profile, stainless Replacement Doors for ND Models GT-0369 Black vinyl clad door, narrow GT Unlaminated door, narrow GT-0369 Laminated door, narrow GT Stainless door, narrow Glass door, narrow, black Glass door, narrow, stainless NOTE: Door gaskets, handles and hinges are sold separately, see page 6 for part numbers 3 /6 3 /6 3 5 /8 9 /6 3 /6 7 /6 7 ½ 3 / Fax /

30 Doors and Related Parts Replacement Glass Doors for Units Manufactured September 003 and After NOTICE: In September of 003, we released new style glass doors for our vertical door coolers. These new style doors fit all of our units manufactured AFTER January 999, However these new style glass doors look different than the glass doors manufactured BETWEEN January 999 and September 003. Please consider this fact if you need to match the look of your replacement glass door with that of existing glass doors. If you need to order the style of glass doors manufactured between January 999 and September 003, please refer to page 5. Replacement Doors for BB, PT, RF, DS, and KC Models Part No. Old Part No. Description Price GT-0000 Stainless Steel Glass Door $ GT-000 Black Vinyl Clad Glass Door GT-000 Laminated Glass Door Door, black, BB/KC (March 5, 07 and after) Door, stainless steel, BB/KC (March 5, 07 and after) Door, laminated glass, left hinge, BB/KC (March 5, 07 and after) Door, laminated glass, right hinge, BB/KC (March 5, 07 and after) Replacement Doors for LP and FV Models Part No. Old Part No. Description Price GT-000 Stainless Steel Glass Door GT-00 Black Vinyl Clad Glass Door GT-00 Laminated Glass Door Replacement Doors for ND Models Part No. Old Part No. Description Price GT-000 Stainless Steel Glass Door GT-00 Black Vinyl Clad Glass Door GT-00 Laminated Glass Door NOTE: Door gaskets, handles, and hinges are sold separately, see page 6 for part numbers 3 5/8" 9 5/8" 3 5/8" 33 3/8" 7 /" 33 3/8" Fax /

31 Shelving, Racks and Related Parts Part No. Old Part No. Description Price GT ⅞" x 0⅛" grey coated shelf (fits BB, BB36, FV, $77.00 ND7 middle door and refrig. end of remote PT models) GT ⅞" x -/6" grey coated shelf with corner notch (fits end doors on BB, and LP models and both doors on FV8) GT ⅞" x 3⅞" grey coated shelf (fits middle doors on BB, LP, PT and RF models) GT ⅞" x 8-/6" grey coated shelf (fits end doors on ND models) GT ⅞" x -/6" grey coated shelf (fits end doors on PT and RF models) ⅞" x -/6" grey coated shelf (fits NDPT8 and 7 coolers) Shelf divider Floor, stainless, fits BGS Floor, stainless, fits BGS Floor, stainless, fits BGS Shelf, stainless, fits BGS Shelf, stainless, fits BGS Shelf, stainless, fits BGS Shelf angle for BGS GT ½" X 3¼" coated shelf (fits CM models) ⅝" X 9⅝" shelf (fits MFV bottom and middle) /6" X 9⅝" shelf (fits MFV top) ⅞" X 0⅛" dry storage shelf (fits DS manufactured before 0/03) (fits BB, BB36, FV, ND7 middle door and refrig. end of remote PT models) GT ⅝" X ½" dry storage shelf (fits DS manufactured after 0/03) GT Floor for DS (manufactured after 0/03) GT ⅞" X 5⅞" dry storage shelf (fits DS36) ⅞" X 8-/6" dry storage shelf (fits end doors on ND models) GT ⅞" X -/6" dry storage shelf (fits DS8 and DS7 ends) GT ⅞" X 3⅞" dry storage shelf (fits DS7, middle) GT-0383 Pilaster GT Thumbscrew, stainless steel, for pilaster GT Clip, for pilaster, stainless steel Nut, acorn, 8/3" natural nylon GT ABS Scuff Channel with mounting screws GT-0038 ABS Scuff Channel (ND models) with mounting screws W-RACK-8 Wine racks, set of two for 8-/6" shelf (shelf not included) W-RACK-0 Wine racks, set of two for 0⅛" shelf (shelf not included) W-RACK- Wine racks, set of two for -/6" shelf (shelf not included) K-RACK-ND Keg rack, stainless, 8¾" (ND end) K-RACK-KC Keg rack, stainless, 0¾" (KC models manufactured before 0//06) K-RACK- Keg rack, stainless, 0¾" (BB self contained & KC, BB end & ND middle) K-RACK- Keg rack, stainless, ½" (BB middle doors) K-RACK-PT Keg rack, stainless, ½" (PT end) Keg rack, stainless, ½" (PT middle) Dry Storage Shelf 8-7/8" x 0-/8" 8-7/8" x -/6" 6 DS Dry Storage Floor 5 Wine Rack (shelf not included) Keg Rack Fax /

32 Refrigeration Compartment Covers Refrigeration Compartment Covers for BB and KC Models After //06 Part No. Old Part No. Description Price Panel, access, BB/KC $.00 Refrigeration Compartment Covers for Endwall BB, ND, KC5, KC7 & KC8 Models GT Grill, black vinyl clad, endwall BB, ND, or KC, 33-/ H, -3/ L, -3/8 W GT-0368 Grill, stainless, endwall BB, ND, or KC, 33-/ H, -3/ L, -3/8 W Grill, unlaminated, endwall BB, ND, or KC, 33-/ H, -3/ L, -3/8 W 0.00 Refrigeration Compartment Covers for PT, and Non Endwall BB, ND5, ND7, KC7, and KC8 Models Grill, black vinyl clad, PT and non-endwall BB, ND, or KC, 33-/ H, -3/ L, -3/8 W Grill, stainless, PT and non-endwall BB, ND, or KC, 33-/ H, -3/ L, -3/8 W Grill, unlaminated, PT and non-endwall BB, ND, or KC, 33-/ H, -3/ L, -3/8 W GT-0368 Grill, black vinyl clad, low refrigeration, PT and non-endwall BB, ND, or KC, / H, -3/ L, -3/8 W GT Grill, stainless, low refrigeration, PT and non-endwall BB, ND, or KC, 9-/ H, / L, -3/8 W Refrigeration Compartment Covers for LP Models GT Grill, black vinyl clad, LP models, 7-/ H, -3/ L, -3/8 W GT Grill, stainless, LP models, 7-/ H, -3/ L, -3/8 W Grill, unlaminated, LP models, 7-/ H, -3/ L, -3/8 W 0.00 Refrigeration Compartment Covers for ND8 and KC8 Models GT Grill, black vinyl clad, 8 refrigeration, 33-/ H, 7-3/ L, -3/8 W GT-0369 Grill, stainless, 8 refrigeration, 33-/ H, 7-3/ L, -3/8 W Refrigeration Compartment Covers for FV and FV8 Models GT-0369 Grill, front, black vinyl clad, ST or FV, 9-3/8 H, 0-7/8 L, 3/8 W GT Grill, front, stainless, ST or FV, 9-3/8 H, 0-7/8 L, 3/8 W Grill, front, black vinyl clad, FV8, 9-3/8 H, -7/8 L, 3/8 W Grill, front, stainless, FV8, 9-3/8 H, -7/8 L, 3/8 W Refrigeration Compartment Covers for 8 Wide Compressor Compartments GT Grill, black vinyl clad, 8 refrigeration, 33-/ H, 7-3/ L, -3/8 W GT Grill, stainless, 8 refrigeration, 33-/ H, 7-3/ L, -3/8 W GT Grill, black vinyl clad, 8 low refrigeration, 9-/ H, 7-3/ L, -3/8 W GT Grill, stainless, 8 low refrigeration, 9-/ H, 7-3/ L, -3/8 W 0.00 Refrigeration Compartment Covers Related Parts GT Grill insert, refrigeration compartment cover, polypropylene, black GT Grill insert, refrigeration compartment cover, polypropylene, gray GT Filter, refrigeration compartment grill insert Laminated compressor compartment trim rail kit, for BB, PT, and ND models Laminated compressor compartment trim rail kit, for LP models Laminated compressor compartment trim rail kit, for special low profile compartments Rubber Bumper Fax /

33 0 Volt Electrical Parts BB Self contained & KC Compressor, Condenser & Related Parts Part No. Description Price Compressor, /6HP, 0V, 50Hz, R3a $ Relay, compressor, /6HP, 0V/50Hz, R3a Overload protector, compressor, /6HP, 0V/50Hz, R3a Automatic defrost timer, 6 hour, 0V, 50Hz Condenser fan motor, 0V Standard BB36 Compressor, Condenser & Related Parts Compressor, /5 HP, 0V, 50Hz, R $ Start capacitor, /5 HP, R, 0V/50Hz Tecumseh compressor Relay, /5 HP, R, 0V/50Hz Tecumseh compressor Overload protector, /5 HP, R, 0V/50Hz Tecumseh Condenser fan motor, 0V, 6 watt Automatic defrost timer, 6 hour, 0V, 50 Hz 3.00 LP60, LP8, LP08, Non Endwall BB60, BB8, BB08, ND5, ND7, ND9, KC8, KC7, KC Compressor, /3 HP, 0V, 50Hz, R $ Start capacitor, for /3 HP R0A and R compressor, 0/50Hz Relay, compressor, /3HP, 0V/50Hz, R Overload protector, compressor, /3HP, 0V/50Hz, R Condenser fan motor, 0V, 6 watt Automatic defrost timer, 6 hour, 0V, 50 Hz 3.00 BB36, BB60, ND5, & KC5 Compressor & Condenser Related Parts For Endwall Models Compressor, /3 HP, 0V, 50Hz, R3a $ Relay, /3 HP 0V 50Hz R3a Tecumseh compressor Overload protector, /3 HP 0V 50Hz R3a Tecumseh compressor Start capacitor, /3 HP 0V 50Hz R3a Tecumseh compressor Condenser fan motor, 9 watt, 0V 50Hz Automatic defrost timer, 6 hour, 0V, 50 Hz 3.00 BB8, BB08, ND7, ND9, KC7 & KC8 Compressor & Condenser Related Parts For Endwall Models Compressor, /3 HP, 0V, 50Hz, R0a $ Start capacitor, for /3 HP R0A and R compressor, 0/50Hz Relay, /3 HP 0V 50Hz R0a compressor Overload protector, /3 HP 0V 50Hz R0a compressor Condenser fan motor, 0V, 6 watt Automatic defrost timer, 6 hour, 0V, 50 Hz Fax /

34 0 Volt Electrical Parts PT60, PT8 & PT08 Compressor & Condenser Related Parts Compressor, /3 HP, 0V, 50Hz, R0a $ Start capacitor, for /3 HP R0A and R compressor, 0/50Hz Relay, /3 HP 0V 50Hz R0a compressor Overload protector, /3 HP 0V 50Hz R0a compressor Condenser fan motor, 0V, 6 watt Automatic defrost timer, 6 hour, 0V, 50 Hz 3.00 FV & FV8 Compressor & Condenser Related Parts Prior to Compressor, /5 HP, 0V, 50Hz, R $ Start capacitor, /5 HP 0V/50Hz R Tecumseh compressor Relay, /5 HP 0V/50Hz R Tecumseh compressor Overload protector, /5 HP 0V/50Hz R Tecumseh compressor Condenser fan motor, 9 watt, 0V 50Hz Automatic defrost timer, 6 hour, 0V, 50 Hz 3.00 FV & FV8 Compressor & Condenser Related Parts After 0/0/ Compressor, /3 HP, 0V, 50Hz, R3a $ Relay, /3 HP 0V 50Hz R3a Tecumseh compressor Overload protector, /3 HP 0V 50Hz R3a Tecumseh compressor Start capacitor, /3 HP 0V 50Hz R3a Tecumseh compressor Condenser fan motor, 9 watt, 0V 50Hz Automatic defrost timer, 6 hour, 0V, 50 Hz 3.00 Vertical Door Cooler Evaporators & Related Parts Rope lighting, 0V, 50Hz, per foot Rope lighting power cord and connector, 0V European plug style Blower motor, 0V (Endwall BB8, BB08, ND7, ND9, KC5, KC7, KC8) Evaporator fan motor, 0V (Endwall BB36, BB60, ND5, & All Non EW Models) Assembly, shroud, evaporator, -fan, - door e/w, 0 Volt Assembly, shroud, evaporator, -fan, - door e/w, 0 Volt, digital t-stat Electrical Components Part No. Description Price Replacement powercord assembly, includes ( ) $ Fax /

35

36 UNPARALLELED UNDERBAR DESIGN & ENGINEERING Expect more more flexibility more features Glastender has the most complete line of bar equipment and the ability to manufacture custom units, giving you virtually unlimited design flexibility. Each piece of equipment is engineered with features that enhance your efficiency, ease your maintenance, and prolong the life of your investment. The flexibility you want. The features you need. Glastender. Expect more. GLASSWASHERS COCKTAIL STATIONS COOLERS FROSTERS BEER SYSTEMS

Operation Manual and Parts Directory

Operation Manual and Parts Directory Operation Manual and Parts Directory ST24, ST36, ST48, ST60, ST72 and ST96 Slide Top Coolers ST36-B ST48-SF Glastender, Inc. 5400 North Michigan Road Saginaw, MI 48604-9780 800.748.0423 989.752.4275 Fax

More information

Operation Manual and Parts Directory

Operation Manual and Parts Directory Operation Manual and Parts Directory Lettuce Crisper LC Glastender, Inc. 5400 North Michigan Road Saginaw, MI 48604-9780 800.748.0423 989.752.4275 Fax 800.838.0888 / 989.752.4444 www.glastender.com Rev.

More information

Operation Manual and Parts Directory

Operation Manual and Parts Directory Operation Manual and Parts Directory ST24, ST36, ST48, ST60, ST72 and ST96 Slide Top Coolers - Prior to 2009/2010* *Slide Top Cooler Serial Number Information This manual is specific to ST24, ST36, ST48,

More information

Operation Manual, Parts Directory and Price List

Operation Manual, Parts Directory and Price List Operation Manual, Parts Directory and Price List Vertical Door Coolers Self-Contained Models - BB, BB36, BB60, BB8, BB08, ND5, ND7, ND9, FV, FV8, LP60, LP8, LP08, PT60, PT8, PT08, KC, KC8, KC5, KC7, KC8

More information

Operation Manual & Parts List. Slide Top Coolers Manufacture date beginning in 2009 and prior to March 27, 2017*

Operation Manual & Parts List. Slide Top Coolers Manufacture date beginning in 2009 and prior to March 27, 2017* Operation Manual & Parts List A Family Company Manufacturing In The USA Since 1969 Slide Top Coolers Manufacture date beginning in 2009 and prior to March 27, 2017* Models: ST24, ST36, ST48, ST60, ST72,

More information

Mug Frosters and Plate Chillers*

Mug Frosters and Plate Chillers* Operation Manual, Parts Directory, and Price List Mug Frosters and Plate Chillers* MF24, MF36, MF48 A Family Company Manufacturing In The USA Since 1969 *This manual is specific to Mug Frosters manufactured

More information

Operation Manual, Parts Directory, and Price List

Operation Manual, Parts Directory, and Price List Operation Manual, Parts Directory, and Price List *Cooler Serial Number Information This manual is specific to self-contained LP coolers manufactured in 2010 and after and prior to SN 134169912 purchased

More information

Operation Manual and Parts Directory

Operation Manual and Parts Directory Operation Manual and Parts Directory MF, MF6, MF8 Mug Frosters and Plate Chillers MF-S MF8-B Glastender, Inc. 00 North Michigan Road Saginaw, MI 860-9780 800.78.0 989.7.7 Fax 800.88.0888 / 989.7. www.glastender.com

More information

Front Venting Self-Contained Coolers*

Front Venting Self-Contained Coolers* Operation Manual, Parts Directory, and Price List A Family Company Manufacturing In The USA Since 1969 Front Venting Self-Contained Coolers* and Mug Frosters* FV24, FV48 MFV24, MFV48 *This manual is specific

More information

Operation Manual, Parts Directory and Price List

Operation Manual, Parts Directory and Price List Operation Manual, Parts Directory and Price List MFV Reach-In Mug Chillers MFV-SS(L) with optional casters This manual applies to MFV models manufactured prior to SN0876N and July 0, 0. For MFV models

More information

Operation Manual. C1SL48 with compressor right, black vinyl-clad doors, and stainless top

Operation Manual. C1SL48 with compressor right, black vinyl-clad doors, and stainless top Operation Manual Self-Contained, Side Serviced Coolers A Family Company Manufacturing In The USA Since 1969 *Cooler Model Information This manual is specific to the following self-contained, side serviced

More information

Operation Manual, Parts Directory, and Price List

Operation Manual, Parts Directory, and Price List Operation Manual, Parts Directory, and Price List BB60, BB84, BB108, ND52, ND72, ND92, BB60BW, BR, WR, BB84BW, BR, WR, BB108BW, BR, WR, ND52BW, BR, WR, ND72BW, BR, WR, ND92BW, BR, WR 2008 Energy Star Compliant

More information

Front Venting Self-Contained Coolers*

Front Venting Self-Contained Coolers* Operation Manual, Parts Directory, and Price List A Family Company Manufacturing In The USA Since 1969 Front Venting Self-Contained Coolers* and Mug Frosters* FV24, FV48 MFV24, MFV48 *This manual is specific

More information

Operation Manual, Parts Directory, and Price List

Operation Manual, Parts Directory, and Price List Operation Manual, Parts Directory, and Price List Self-Contained Back Bar Coolers A Family Company Manufacturing In The USA Since 1969 *Cooler Serial Number Information This manual is specific to self-contained

More information

Operation Manual & Parts List

Operation Manual & Parts List Operation Manual & Parts List A Family Company Manufacturing In The USA Since 1969 GT-2, GT-30 Glasswashers (Manufactured after June 1, 1990 with digital temperature gauges) GT-2-CW GT-30-CCW Glastender,

More information

Vinfinity Wine Preservation System

Vinfinity Wine Preservation System Operation Manual & Parts List A Family Company Manufacturing In The USA Since 1969 Vinfinity Wine Preservation System DBCA-12-V DS12 DBGR-24-RS-V Glastender, Inc. 5400 North Michigan Road Saginaw, MI 48604-9780

More information

GT-18, GT-18+1, GT-18+1L, GT-18+1R, GT-18+2, GT-18+2-IC Glasswashers (Manufactured after October 1, 1994 with motor driven drain stopper)

GT-18, GT-18+1, GT-18+1L, GT-18+1R, GT-18+2, GT-18+2-IC Glasswashers (Manufactured after October 1, 1994 with motor driven drain stopper) Parts Directory GT-18, GT-18+1, GT-18+1L, GT-18+1R, GT-18+2, GT-18+2-IC Glasswashers (Manufactured after October 1, 1994 with motor driven drain stopper) GT-18+2 GT-18 Glastender, Inc. 5400 North Michigan

More information

Operation Manual and Parts Directory

Operation Manual and Parts Directory Operation anual and Parts Directory LC65, LC85, LC86, LC44, LC47 Draft Pro Remote Glycol Line Chillers LC65 LC44 Glastender, Inc. 5400 North ichigan Road Saginaw, I 48604-9780 800.748.0423 989.752.4275

More information

Bottle Disintegration System

Bottle Disintegration System Operation Manual & Parts List A Family Company Manufacturing In The USA Since 1969 Bottle Disintegration System Glastender BDS Operation and Maintenance Video - http://www.glastender.com/videos/ This video

More information

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the Bill of Lading to ensure all crates

More information

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual For service information call 800-544-3057 Please have the following information available before calling. Information can be found on

More information

RPI Industries, Inc.

RPI Industries, Inc. IMPORTANT: THE FOLLOWING INFORMATION SHOULD BE RETAINED FOR FUTURE REFERENCE RPI Industries, Inc. building a better case for sales BAKERY and DELI USE AND SERVICE MANUAL WARRANTY INFORMATION SPECIFICATIONS

More information

InstructIon Manual KrEs EQuIPMEnt stands

InstructIon Manual KrEs EQuIPMEnt stands Instruction Manual Instruction Manual SELF-CONTAINED AND REMOTE Kairak KRES model refrigerated equipment stand units are available in many lengths from 36 to 120 inches long. These units are available

More information

BOTTLE COOLERS SLIDE TOP INSTALLATION AND OPERATION INSTRUCTION MANUAL MODEL SERIES BC24- BC36- BC48- BC72- BC96-

BOTTLE COOLERS SLIDE TOP INSTALLATION AND OPERATION INSTRUCTION MANUAL MODEL SERIES BC24- BC36- BC48- BC72- BC96- BOTTLE COOLERS SLIDE TOP INSTALLATION AND OPERATION INSTRUCTION MANUAL MODEL SERIES BC24- BC36- BC48- BC72- BC96- Printed in the USA Rev. 11/2012 No. BC-1.02 WE RAISE THE BAR TABLE OF CONTENTS WARRANTY

More information

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET FOOD WARMING/ MERCHANDISING CABINET MODEL 925W This warmer/merchandiser provides heated circulating air to keep foods fresh and evenly warmed. It is constructed of stainless steel and tempered glass for

More information

WCPT-3 and WCPT-4. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE. Drop-in Display Cases

WCPT-3 and WCPT-4. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE. Drop-in Display Cases WCPT-3 and WCPT-4 Service and Installation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately.

More information

B a r Re f r i g e r a t i o n

B a r Re f r i g e r a t i o n Bar Refrigeration Your one - stop bar refrigeration shop Lighted liquor displays designed for use with glass ice display units have a front light channel to illuminate the ice bath (field installed glass

More information

RPI Industries, Inc.

RPI Industries, Inc. RPI Industries, Inc. AIR SCREEN and SELF-SERVE OPERATION AND SERVICE MANUAL WARRANTY INFORMATION For Models Stratus SCRFC48R-SSI SCRFC60R-SSI SCRFC72R-SSI SCRFC48R-SSII SCRFC72R-SSII SCRFC48R-SSIII SCRFC72R-SSIII

More information

Installation & Operation Manual

Installation & Operation Manual Installation & Operation Manual Glass Frosters FR Series FR48 SS shown C US Form No. Z2296 Rev. 01.16.2015 Glass Frosters Installation & Operation Manual JOB AREA ITEM NO. MODEL NO. FR24 SERIES FR36 SERIES

More information

Installation & Operation Manual

Installation & Operation Manual Installation & Operation Manual Flat Top Bottle Cooler BC Series BC72 shown C US Form No. Z2295 Rev. 04.05.2018 JOB AREA ITEM NO. MODEL NO. BC24 SERIES BC36 SERIES BC48 SERIES BC24 shown BC72 shown BC48LT

More information

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL www.polartemp.com TABLE OF CONTENT Disclaimer.......................................... Page 3 Inspection, unpacking and FMU setup.................. Page

More information

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS INSTALLATION and OPERATION INSTRUCTIONS Single Door cooler series MODEL NOS. CS32SB CS32SG CS32SS CS32ST IMPORTANT INFORMATION To register your product, visit our web site at (www.perlick.com). Click on

More information

INSTRUCTIONS FOR OPERATION AND CARE OF. P.O. Box 3527 City of Industry, CA, , U.S.A

INSTRUCTIONS FOR OPERATION AND CARE OF. P.O. Box 3527 City of Industry, CA, , U.S.A INSTRUCTIONS FOR OPERATION AND CARE OF GLACIERFREEZE GF-12 P.O. Box 3527 City of Industry, CA, 91744-0527, U.S.A. 800-782-7706 626-968-6681 www.whitehallmfg.com Member of 6702-488-000 August 2012 WARNING

More information

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS INSTALLATION and OPERATION INSTRUCTIONS Glass Frosters MODEL NOS. FR24 Series FR36 Series FR48 Series FR60 Series c IMPORTANT INFORMATION This manual has been prepared to assist you in the installation

More information

Installation, Operation & Troubleshooting Instructions Pizza Table Refrigerator

Installation, Operation & Troubleshooting Instructions Pizza Table Refrigerator R e f r i g e r a t i o n a t i t s b e s t Installation, Operation & Troubleshooting Instructions Pizza Table Refrigerator For Models: VPT- 46-NS, VPT- 65-NS, VPT- 88-NS, VPT-119-NS Manual Part No.: 50842804

More information

Service Parts, Kits and Accessories

Service Parts, Kits and Accessories The parts identification guides on the following pages have been designed to give a quick reference to component parts used on pilot ignition agricultural building heaters. The guides identify components

More information

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers Please read this manual completely before installing or operating this unit! BACF11 BACF15 BACRF14 Blue Air reserves

More information

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call Service Manual Design Basics Hot Food Tables Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF For Service Information, Call 800-544-3057 Please provide the following information: - Model number - Serial

More information

Wax Base Heater & Dispenser

Wax Base Heater & Dispenser Wax Base Heater & Dispenser Service Manual Models: IDWB2/0900, IDWB2/0775, IDWB3/0900, IDWB3/0775, IDWB4/0900, IDWB4/0775 Introduction............................................................................

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl100rnl, BFL125RNL Item Stock Number(s): BFL100RNL, BFL125RNL IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions 634 10 Sunnen Drive St. Louis, MO 63143 telephone: 314-678-6336 fax: 314-781-2714 www.bloomfieldworldwide.com OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901 Includes: Installation

More information

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS INSTALLATION and OPERATION INSTRUCTIONS SINGLE DOOR freezer MODEL NOS. FN FS Finished Stainless Steel Top Non-Finished Top FS FN IMPORTANT INFORMATION This manual has been prepared to assist you in the

More information

Ui REFRIGERATOR SPEC SHEET

Ui REFRIGERATOR SPEC SHEET Ui REFRIGERATOR SPEC SHEET ISOMETRIC VIEW 19 7/8 20 1/2 32 3/4 FRONT VIEW NOTES: 1. CUTOUT DIMENSIONS: 20 1/2"W X 33"L X 20 3/4"D 2. CUTOUT DIMENSIONS ARE FOR REFRIGERATOR ONLY. REFER TO STAINLESS STEEL

More information

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL TABLE OF CONTENTS PAGE # SAFETY INSTRUCTIONS......... 2 INSTALLATION INSTRUCTIONS................... 3 CABINET LOCATION GUIDELINES...

More information

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST www.everest ref. com Owner s Manual for models: Back Bar Coolers " Deep Back Bar Coolers Glass Door Back Bar Coolers " Deep Galss Door Back Bar Coolers " Deep Galss Sliding Door Back Bar Coolers EBB3,

More information

ELECTRICAL DATA: FEATURES: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET. 15 Width 7 Width

ELECTRICAL DATA: FEATURES: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET. 15 Width 7 Width FOOD WARMING/ MERCHANDISING CABINET MODEL 323HH MODEL 323HH-7 15 Width 7 Width With the ability to hold a point-of-purchase advertisement, these sleek, compact warmers are sure to draw eye catching attention.

More information

01550-RevG IMPORTANT INSTRUCTIONS WEBSITE MANUAL

01550-RevG IMPORTANT INSTRUCTIONS WEBSITE MANUAL 01550-RevG-082712 IMPORTANT INSTRUCTIONS WEBSITE MANUAL english model: FSAF Food Server Advantage TM Fudge/Caramel 120V Series 12A 85070 Unit Set-Up Always clean unit thoroughly before first use. See UNIT

More information

e Heater/Exhaust Fan/Light User s Guide

e Heater/Exhaust Fan/Light User s Guide e Heater/Exhaust Fan/Light User s Guide abflh70l, BFLH85L Item Stock Number(s): BFLH70L, BFLH85L IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

RPI Industries, Inc.

RPI Industries, Inc. IMPORTANT: THE FOLLOWING INFORMATION SHOULD BE RETAINED FOR FUTURE REFERENCE RPI Industries, Inc. building a better case for sales CONFECTIONERY USE & SERVICE MANUAL WARRANTY INFORMATION For Models Bradford

More information

Installation & Operations Manual for. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers. 4/17 Rev.

Installation & Operations Manual for. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers. 4/17 Rev. Installation & Operations Manual for BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers 4/17 Rev. D 57-02398 4/17 Rev. D 57-02398 2 TABLE OF CONTENTS INTRODUCTION.. 4

More information

INSTALLATION AND OPERATION INSTRUCTIONS STANDARD BACK BAR COOLERS, SELF CONTAINED MODEL NOS.

INSTALLATION AND OPERATION INSTRUCTIONS STANDARD BACK BAR COOLERS, SELF CONTAINED MODEL NOS. INSTALLATION AND OPERATION INSTRUCTIONS STANDARD BACK BAR COOLERS, SELF CONTAINED MODEL NOS. CS Series IMPORTANT INFORMATION Fill out the enclosed warranty card and mail to the Perlick Corporation to register

More information

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS INSTALLATION and OPERATION INSTRUCTIONS Custom Pass-thru back bar cabinet self contained and remote MODEL NOS. PS Series PR Series PS Series PR Series IMPORTANT INFORMATION To register your product, visit

More information

Installation & Operation Manual Ice Cream Freezers

Installation & Operation Manual Ice Cream Freezers Installation & Operation Manual Ice Cream Freezers Please read this manual completely before installing or operating this unit! BACF11 BACF15 Blue Air reserves the right to make product modification at

More information

MANUAL FOOD HOLDING & TRANSPORT CABINETS WITTCO MODEL NUMBERS

MANUAL FOOD HOLDING & TRANSPORT CABINETS WITTCO MODEL NUMBERS O P E R A T I O N S M A I N T E N A N C E MANUAL FOOD HOLDING & TRANSPORT CABINETS WITTCO MODEL NUMBERS 1826-4 1826-7-BC-IS 1826-7 1826-13-BC-IS 1826-7-BC 1826-15-BC-IS 1826-13-BC 1826-15-BC 1826-40-BC

More information

Professional Warming Drawer and Warming Drawer Cabinet

Professional Warming Drawer and Warming Drawer Cabinet Professional Warming Drawer and Warming Drawer Cabinet Care & Use/Installation Instructions Models: (C)VQEWD5300SS (C)VQEWD5420SS IMPORTANT SAFETY INSTRUCTIONS WARNING: Read this manual carefully and completely

More information

Installation & Operations Manual for R-290 SERIES. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers 2/

Installation & Operations Manual for R-290 SERIES. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers 2/ Installation & Operations Manual for R-290 SERIES BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers 2/19 57-02650 2/19 57-02650 2 TABLE OF CONTENTS INTRODUCTION.. 4 STORE

More information

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N CLIMAGUARD Air-to-Air Outdoor Heat Exchangers TX23, TX33, TX38, TX52 Model INSTRUCTION MANUAL Rev. H 2015 Pentair Equipment Protection P/N 10-1008-221 87976519 TABLE OF CONTENTS RECEIVING THE HEAT EXCHANGER...3

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Refrigerated Merchandisers with Air-Over Displays Refrigerated Low-Profile Mobile Merchandiser Refrigerated High-Profile Mobile Merchandiser Refrigerated Grab-N-Go Merchandiser

More information

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER G-Series Cooler GCG-10 UPRIGHT COOLER Manual is for the following models: GCG-10-N33EB G-10-N33EB Instruction Manual Manual is for the following models: GCG-10-N33EB G-10-N33EB Instruction Manual GCG-10

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Refrigerated Island Merchandiser FOR PARTS & SERVICE Contact: Piper Products, Inc. Phone: (800) 544-3057 Ask for Service Department IMPORTANT! This manual contains important

More information

RPI Industries, Inc.

RPI Industries, Inc. RPI Industries, Inc. AIR SCREEN and SELF-SERVE OPERATION AND SERVICE MANUAL WARRANTY INFORMATION For Models Olympus Bandit Bravo SCAS36R SCRFC3660R SCRFC3648R SCAS48R SCRFC4860R SCRFC4848R SCAS60R SCRFC6060R

More information

INSTALLATION AND OPERATION INSTRUCTIONS CUSTOM BACK BAR CABINET SELF CONTAINED AND REMOTE

INSTALLATION AND OPERATION INSTRUCTIONS CUSTOM BACK BAR CABINET SELF CONTAINED AND REMOTE INSTALLATION AND OPERATION INSTRUCTIONS CUSTOM BACK BAR CABINET SELF CONTAINED AND REMOTE MODEL NOS. BS Series BR Series BS Series BR Series IMPORTANT INFORMATION Fill out the enclosed warranty card and

More information

OWNER S MANUAL. Installation Operation Maintenance. Saturn Equipment

OWNER S MANUAL. Installation Operation Maintenance.   Saturn Equipment OWNER S MANUAL Saturn Stainless Steel Sandwich/Salad Table & Mega Top Refrigerators Undercounter Refrigerators & Undercounter Freezers Installation Operation Maintenance Saturn Equipment www.saturnequipment.com

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS AquaArctic Remote Water Chiller A9100080 -A TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 1.800.591.9360 Technical Assistance Fax: 1.626.855.4894

More information

A PROUD HERITAGE OF EXPERIENCE & QUALITY. Beverage Cooler VT-SC-1

A PROUD HERITAGE OF EXPERIENCE & QUALITY. Beverage Cooler VT-SC-1 A PROUD HERITAGE OF EXPERIENCE & QUALITY Beverage Cooler VT-SC-1 O W N E R S M A N U A L W W W. V I N O T E M P. C O M Your Beverage Cooler This unit can be used for Storage and/or Service. The cooler

More information

Reach-In Refrigerators and Freezers Service Manual

Reach-In Refrigerators and Freezers Service Manual Reach-In Refrigerators and Freezers Service Manual Part No. 80-0899-3 Rev. A 11/96 Safety Notices As you work on the Reach-In, be sure to pay close attention to the safety notices in this manual. Disregarding

More information

Technical Manual and Replacement Parts List. f Real Freezers

Technical Manual and Replacement Parts List. f Real Freezers Technical Manual and Replacement Parts List f Real Freezers MODELS: SKF27G/CFRL (SHOWN) SKF27GB/CFRL 1600 Xenium Lane North, Minneapolis, MN 55441-3787 Phone (763) 923-2441 1 Specifications Subject to

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Salad Bars Olive Bars Food Prep Cases Refrigerated Cases with Air-Over Displays Refrigerated Cases with Coppered Cold Well Displays Cases with Under-Counter Refrigerators

More information

MODEL (Single Door) MODEL (2 Door pass through)

MODEL (Single Door) MODEL (2 Door pass through) FOOD WARMING/MERCHANDISING CABINET MODEL 680-1 (Single Door) MODEL 680-2 (2 Door pass through) This warmer provides bottom heat to keep crusts crisp. The illuminated shelves are thermostatically controlled

More information

WARMING AND MERCHANDISING CABINET

WARMING AND MERCHANDISING CABINET WARMING AND MERCHANDISING CABINET Above red graphics now replace green graphics shown in photo. MODEL 695 (Single door unit shown) MODEL 695-S (Single door unit shown) Snack foods have to be hot and moist

More information

Bottle Coolers. Manual for installation, use and Maintenance

Bottle Coolers. Manual for installation, use and Maintenance Bottle Coolers. Manual for installation, use and Maintenance 1 RECEIVING AND INSPECTING Upon receiving your new Fagor Equip, check the package and the machine for any damages that may have occurred during

More information

BMG-HGP & BMG-SLP Model Bottom Mounted Full-Length Glass Door Refrigerator Merchandisers

BMG-HGP & BMG-SLP Model Bottom Mounted Full-Length Glass Door Refrigerator Merchandisers Installation & Operations Manual for BMG-HGP & BMG-SLP Model Bottom Mounted Full-Length Glass Door Refrigerator Merchandisers Sollatek controller Rev. 08-09-13 2 TABLE OF CONTENTS INTRODUCTION.. 4 STORE

More information

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS INSTALLATION and OPERATION INSTRUCTIONS Utility Coolers MODEL NOS. US4KP US10KP IMPORTANT INFORMATION This manual has been prepared to assist you in the installation of your Utility Cooler and to acquaint

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS SPECIALTY REFRIGERATED TRANSPORT CABINETS FOR SATELLITE LOCATIONS RBQ-96 Caution: Read the instructions before using the machine. CONGRATULATIONS......and thank you for purchasing

More information

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the Bill of Lading to ensure all crates

More information

Quality Refrigeration OWNER S MANUAL. Instructions for the installation, operation and maintenance of Traulsen: Heated Banquet & Transport Carts

Quality Refrigeration OWNER S MANUAL. Instructions for the installation, operation and maintenance of Traulsen: Heated Banquet & Transport Carts Quality Refrigeration OWNER S MANUAL Instructions for the installation, operation and maintenance of Traulsen: Heated Banquet & Transport Carts This Traulsen unit is built to our highest quality standards.

More information

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne. ELECTRONIC FAUCETS INSTRUCTION MANUAL 100 Haul Road Wayne, NJ 07470 Toll Free: (800) 631-0442 customerservice@krowne.com krowne.com Model 16-196 1 3 2 4 6 5 7 1. 2. 3. 4. 5. 6. 7. Aerator Sensor with Cable

More information

Glass Washer. PERLICK Glass Washer NO ONE WORKS HARDER TO KEEP YOU COOKING. WHALEY FOODSERVICE REPAIRS ITEM PART NO. NO.

Glass Washer. PERLICK Glass Washer NO ONE WORKS HARDER TO KEEP YOU COOKING. WHALEY FOODSERVICE REPAIRS ITEM PART NO. NO. Glass Washer PERLICK Glass Washer 1 50567 Glasswasher Control 2 52536 Spray Arm Drive Motor 3 50445 Wash Pump 4 52528 Pump Motor Capacitor 5 52652-1 Water Inlet Valve 6 52669-1 Band Heater 7 52626A-B Rinse

More information

FOOD WARMING/MERCHANDISING CABINET

FOOD WARMING/MERCHANDISING CABINET FOOD WARMING/MERCHANDISING CABINET FEATURES: - Acrylic display - Adjustable thermostat - Temperatures from 80 F to above 150 F. - Stainless steel corners and base - 2-door self-serve option available -

More information

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide Installation Manual and Owner s Guide IAQ Series Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application PCOB-09012-0--A - 9" PCO BULB PCOB-14024-0--A - 14" PCO BULB 67202220344 Revised 07-12

More information

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others

More information

WARMING AND MERCHANDISING CABINET

WARMING AND MERCHANDISING CABINET WARMING AND MERCHANDISING CABINET MODEL 695 MODEL 695-S (Two door unit shown) (Single door unit shown) Snack foods have to be hot and moist to be appealing. Cold won t do... Dry won t do. Wisco s model

More information

INSTRUCTION MANUAL KBD DROP-IN PAN CHILLER

INSTRUCTION MANUAL KBD DROP-IN PAN CHILLER INSTRUCTION MANUAL KBD DROP-IN PAN CHILLER INSTRUCTION MANUAL KBD SELF CONTAINED AND REMOTE MODELS BLU TECHNOLOGY Kairak BLU refrigeration Drop-in Pan Chillers are designed to provide consistent, uniform

More information

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS REFRIGERATED COMPRESSED AIR DRYER WRA-0050 WRA-0200 WARNING READ ALL INFORMATION IN THIS MANUAL BEFORE BEGINNING INSTALLATION

More information

CRISP N HOLD FRIED FOOD HOLDING CABINET MODELS: CNH14, CNH18, CNH28, CNH40 OWNERS / OPERATORS MANUAL

CRISP N HOLD FRIED FOOD HOLDING CABINET MODELS: CNH14, CNH18, CNH28, CNH40 OWNERS / OPERATORS MANUAL CRISP N HOLD FRIED FOOD HOLDING CABINET MODELS: CNH14, CNH18, CNH28, CNH40 OWNERS / OPERATORS MANUAL MANUFACTURED BY: CARTER-HOFFMANN 1551 McCORMICK AVENUE MUNDELEIN, IL 60060 U.S.A. PHONE: 847-362-5500

More information

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Milk Coolers Installation and Operation Manual Please read this manual completely before attempting

More information

POLAR TEMP XPORTABLE ICE MERCHANDISER SETUP MANUAL

POLAR TEMP XPORTABLE ICE MERCHANDISER SETUP MANUAL POLAR TEMP XPORTABLE ICE MERCHANDISER SETUP MANUAL www.polartemp.com TABLE OF CONTENTS Disclaimer.......................................... Page 3 Inspection and unpacking..............................

More information

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350 Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350 TECHNICAL MANUAL Section TABLE OF CONTENTS Page Section 1. TROUBLESHOOTING... 1-1 1-1. Introduction... 1-1 1-2.

More information

COMFORT PACK INSTALLATION AND MAINTENANCE INSTRUCTIONS

COMFORT PACK INSTALLATION AND MAINTENANCE INSTRUCTIONS R-410A - C MODELS COMFORT PACK PACKAGED THRU-THE-WALL AIR CONDITIONER WITH ELECTRIC HEAT INSTALLATION AND MAINTENANCE INSTRUCTIONS National Comfort Products 539 Dunksferry Road Bensalem, PA 19020 (215)

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl50uq, BFL60UQ, BFL70, BFL85 Item Stock Number(s): BFL50UQ, BFL60UQ, BFL70, BFL85 IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY

More information

Xaact Spot. Xaact Hot Spot

Xaact Spot. Xaact Hot Spot Xaact Spot & Xaact Hot Spot INFORMATION & OPERATING INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE 78-00012 Rev. 101211 1 CONTENTS: Machine Specifications............

More information

Before Putting Into Use. Important. Tips for Energy Savings

Before Putting Into Use. Important. Tips for Energy Savings Before Putting Into Use Before connecting the appliance to the power supply, let it stand for about 2 hours, which will reduce a possibility of malfunctions in the cooling system due to transport handling.

More information

Refrigerators. Technical Manual and Replacement Parts List FORM NO REV H MODEL SKTTR7FW MODEL SKC1220W

Refrigerators. Technical Manual and Replacement Parts List FORM NO REV H MODEL SKTTR7FW MODEL SKC1220W Technical Manual and Replacement Parts List Refrigerators MODEL SKTTR7FW MODEL SKC1220W 1600 Xenium Lane North, Minneapolis, MN 55441-3787 Phone (763) 923-2441 FORM NO. 28963 REV H 1 Specifications Subject

More information

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50 3227447 Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50 GENERAL SAFETY INFORMATION 1. PRESSURIZED DEVICES: This equipment is a pressure containing device.

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MOBILE HEATED DISH CABINET TM HDC Series Stores, heats, and holds dishes. CONGRATULATIONS... HDC-252-I Heated model shown with flip back top opened....and thank you for purchasing

More information

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- 8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe

More information

Service Manual Models CPH2 & CPH3

Service Manual Models CPH2 & CPH3 Plate Heater Service Manual Models CPH2 & CPH3 888-892-2213 alluserv.com Plate Heater Service Manual Models CPH2 & CPH3 Table of Contents Introduction...................................................2

More information

11 0 Wo o d c r e s t R o a d, C h e r r y H i l l, N J For Models: VR-1, VR-2, VR-3 VF-1, VF-2, VF-3

11 0 Wo o d c r e s t R o a d, C h e r r y H i l l, N J For Models: VR-1, VR-2, VR-3 VF-1, VF-2, VF-3 Installation, Operation and Troubleshooting Instructions Reach-In Refrigerator and Freezer Cabinets For Models: VR-1, VR-2, VR-3 VF-1, VF-2, VF-3 RS-1D-S7, RS-2D-S7, RS-3D-S7 FS-1D-S7, FS-2D-S7, FS-3D-S7

More information

OPERATIONS MAINTENANCE MANUAL

OPERATIONS MAINTENANCE MANUAL OPERATIONS MAINTENANCE MANUAL COOK & HOLD OVEN SYSTEMS WITTCO MODEL NUMBERS 1300-AD-SS 1300-AD-SS-SPLIT LIMITED WARRANTY Wittco warrants the Products that it manufactures to be free from defects in materials

More information

Refridgerated Topping Rail Model: RTR-8 Intended for other than household use. Unit must be kept clear of combustibles at all times.

Refridgerated Topping Rail Model: RTR-8 Intended for other than household use. Unit must be kept clear of combustibles at all times. DESIGNED SMART. BUILT SOLID. INSTALLATION AND OPERATING INSTRUCTIONS Refridgerated Topping Rail Model: RTR-8 Intended for other than household use. Unit must be kept clear of combustibles at all times.

More information