Operation Manual. WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. (Version 2.1.1) written for WAC-47/-60/-80/-100 models

Size: px
Start display at page:

Download "Operation Manual. WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. (Version 2.1.1) written for WAC-47/-60/-80/-100 models"

Transcription

1 WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves Certifications by CE /MDD Marked Products. ISO 9001 Certified. PL Insurance. Validation(IQ&OQ) Service. Patented( No ) Jog Shuttle Control System. Operation Manual (Version 2.1.1) written for WAC-47/-60/-80/-100 models WAC-60 WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves, 60Lit. Sales & Basic A/S : By the Nearest Official Distributors. Man201 (02 Jul. 2013)

2 EC Declaration of Conformity DAIHAN Scientific Co., Ltd. Seoul-city, Korea declares that the medical device described hereafter, Autoclave Model No. : WAC-47, WAC-60, WAC-80 has been classified as Class lia (Annex IX Rule, 9) and is in conformity with the essential requirements and provisions of Council Directive 93/42/EEC, is subject to the procedures set out in Annex II of Directive 93/42/EEC under the supervision of Notified Body Nemko AS (NB. No ; 0470), P.O.Box 73, Blindern, N-0314 OSLO, Norway. Safety Performance EN :1990+A1:1993+A2:1995 +A3:1996 EMC EN :2001 June, 2008 Quality Assurance Director DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 2/51

3 DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 3/51

4 Contents Page 1. Safety Instructions Before Use Introduction Package Contents Appearance and Naming Installation Cautions in Use Controller Details Operation Specifications Functional Block Diagram Maintenance Troubles & Solutions Certificate DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 4/51

5 Safety Instructions 1 Please read this carefully for the safety before using the device. The indicated cautions are related to the safety and you should observe all safety and warning instructions. Symbols (Pictograms) and the meaning This symbol indicates caution (Including warning). There will be concrete descriptions. This symbol indicates inhibition regarding modification. This symbol indicates inhibition. There will be concrete description. This symbol indicates caution regarding heat. This symbol indicates the risk of explosion or fire. This symbol indicates the user must be kept away while operation. This Symbol indicates that this product is to be collected separately. The following apply only to users in European countries: This product is designated for separate collection at an appropriate collection point. Do not dispose of as household waste. This product is required to comply with the European Union s Waste Electrical & Electronic Equipment(WEEE) Directive 2002/96/EC Please read following warning for safety and proper use. WARNING Do not use a power source other than which the unit is designed to operate on. Inappropriate power supply may result in damage to the equipment. Adhere to all electrical codes. Please do not touch with wet hands. It may be caused an electric shock. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 5/51

6 Do not handle the power cord harshly. Disconnection or short may cause if you bend or put a heavy thing on the device. When you take a plug out in a wall socket, turn the power off and then take the plug out carefully. Insert the plug securely into a wall socket. Loose connections result in excessive heat generation to the device and may cause arcing to occur at the connection. Avoid using multi-point extension power cords. It may cause excessive heat generation and be the cause of a fire. If you extend the power cord, use the cord to have sufficient electric capacity. Be sure to operate the device only with the specified power supply. When you connect the product specified by 100V to 200V, it may be caused to over-heat, electric shock or a short circuit to each part. Do not connect wrong electricity since it is the cause of a fire. Disconnect the power supply plug if the unit is not going to be used for an extended period of time. This Symbol indicates that this product is to be collected separately. The following apply only to users in European countries: This product is designated for separate collection at an appropriate collection point. Do not dispose of as household waste. This product is required to comply with the European Union s Waste Electrical & Electronic Equipment(WEEE) Directive 2002/96/EC Refer to the Warnings regarding Installation stated in the Section 7. Refer to the Warning and Cautions regarding use of the device stated in the Section 8. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 6/51

7 Before Use 2 Thank you very much for purchase of WiseClave Sterilizer). WAC-47/-60/-80/-100 Autoclave (Steam This operation manual describes performance, proper usage, cautions and notices for use of the purchased product. Before use, please confirm this manual and use properly. Please read carefully and thoroughly all the safety instructions described in the Section 1 again. And also, please keep this manual. Modifications of exterior, interior, mechanism, electric/electronics or any other specifications could be made without notice to improve the quality and performance of the product. PL Insurance Coverage In preparation for accidents that may develop in the course of using products produced by DAIHAN Scientific, we subscribed to following PL Insurance coverage to give our customers a piece of mind when using the product. [Contents] Insurance: Products Liability Insurance Issuer: Machinery Insurance Cooperative Limit of Liability: Bodily Injury/Property Damage, 100 million KRW each Territory: Worldwide (U.S Excluded) Emergency Contact: DAIHAN Scientific (TEL: , FAX: ) DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 7/51

8 Introduction 3 WiseClave WAC-series Autoclaves (Steam Sterilizers) are useful for various kind of laboratory works such like Chemistry, Life Science, Medical Science, Pharmacology, etc. Convenience and safety in use is considered in developing and manufacturing this product. Key features are as follows; DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 8/51

9 Package Contents 4 WAC-47/-60/-80/-100, Autoclave (Steam Sterilizer)... [ 1 ] Wire Basket Set... [ 2 ] Operation Manual... [ 1 ] Models (a) WAC-47 : Steam Sterilizers, Digital Fuzzy-controlled Autoclaves, 47Liter. (b) WAC-60: Steam Sterilizers, Digital Fuzzy-controlled Autoclaves, 60Liter. (c) WAC-80 : Steam Sterilizers, Digital Fuzzy-controlled Autoclaves, 80Liter. (d) WAC-100 : Steam Sterilizers, Digital Fuzzy-controlled Autoclaves, 100Liter. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 9/51

10 Appearance and Naming 5 1. Exterior <Front View> < Left Side View> 1 Lever 2 Lid Stiffener 3 Lid Clamp 4 Lid with Silicon packing 5 Pressure Gauge 6 Control Panel 7 Door Fastener 8 Door of Room for Electric Distribution Plane and Pipe Assembly 9 Moving Wheel 10 Expention Open Hole DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 10/51

11 < WAC-47 & -60 model> <WAC-80 & -100 model> < Rear Side View> 10 Power Switch and/or Leakage Breaker 11 Power Cord 12 Plug (for Single-phase 230V AC with Ground) 13 Socket with Wiring connector DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 11/51

12 2. Pipe Assembly and Electric Distribution Plane Safety Knob 15 Manual purge valve 16 Water Drain Valve 16 DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 12/51

13 Installation 6 1. After receiving the unit and putting it on the specified place of use remove the wrapping. 2. After positioning the unit, lock the moving wheel 10 in order to make position fixed and the unit stable. 3. Check the unit whether there are eventual transport damages or not. In case there are some transport damages found please inform the forwarder and your contractor. If there is no damage, please go to next point Let the unit stand for a few minutes so that the all the internal parts and components of the unit can be stabilized. 5. Open the door at the left side of the unit. You can find a room for pipe assembly and electric distribution plane. Please check carefully if there is anything wrong including disconnection of the electric wire, breakage of pipe or fitting element. In case there is any kind of damage found, please inform the forwarder and your contractor. If you cannot find anything wrong, please go to next point For normal use of the unit, confirm that the valve 16 is open, and water drain valve closed. 7. Connect the main power cord to the socket. 8. (NOTE) If you bye WAC-80 or WAC-100, power consumption of the heater in the vessel is too high to use normal wall socket. (Typical wall socket in EU and Asian countries permits around 3kW maximum per socket) So, a big 3-pole plug (for single-phase 230V AC with ground) 13 comes with power cord, and a socket with wiring connector 14 is supplied together as seen in the picture on the page 10. You have to wire the power supply line of enough electric power (4kW for WAC-80 and 5kW for WAC-100 at least) to the supplied connector 14 before plugging. 9. If such a big power supply line is not available in the room where the unit is installed, you have to contact the appropriate person who is in charge of electric facilities in your company or organization. 17 is DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 13/51

14 WARNING Place the device on a level, horizontal surface (floor) to support the capacity of the device without vibration. Do not install at a dangerous place. Do not operate the device where there are flammables. It could be caused serious accidents like explosion or fire. Do not operate the device outside. Avoid areas where the sun shines or rain directly on the device. It is very dangerous as cause over-heat or a short circuit. Do not tilt or lay down the device, and do not impact the body of the device. The device includes shock-sensitive pipes and fittings, which could be damaged by the tilt or impact. Do not install the device where it can get damp or dust. It may be caused overheating, a short circuit or a fire by damp or dust inside of the device. Do not use this device when temperature falls below 20 C and rise above 40 C. Do not use the device at a place with high temperature. Do not operate the device near a heater, blowing an air-conditioner. It may be caused an accident by overheating. The device should be set at a well ventilated place. Be sure the holes on the side or rear surface of the body are not blocked by a wall or an object. Do not operate the device at a poor ventilated place or use closed. It may cause a fire or damage of the device as not to release heat or insufficient ventilation may result. Set the device a lightening place. When you set the device at a dark place, it may cause an unexpected accident by mistake in operation. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 14/51

15 Cautions in Use 7 WARNING Be careful to operate the device. You MUST read this manual carefully and completely before using. The device should only be operated by laboratory personnel especially trained for this purpose and familiar with all precautionary measures required for working in a laboratory. If unexpected sound, smell or smog is generated after connecting electric power, pull out the main plug and contact manufacturer or a supplier. Do not put any objects insides. When an object that is easy to be combustible is like a stone, a metal or paper goes insides, it may cause a fire, an electric shock or a break down. If do, pull out the mains plug from a socket and contact a manufacturer or a supplier. Do not disassemble or remodeling by yourself. It may cause damage to the designed safety. We do not have any duties for an accident, quality deterioration or a defect caused by a customer. All the mechanisms and electric/electronic devices in this machine are designed and developed by the manufacturer. The devices could be disassembled and serviced only by the engineers of manufacturer or by engineers approved by manufacturer. Do not touch the device with wet hand while operation. Do not turn on and off frequently. It could damage the compressor by overload. This device must be connected to an earthed power supply. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 15/51

16 CAUTION Only demineralised or distilled water MUST be used. If dirty water is used, it will cause damage of all the components inside the vessel, inner surface of the vessel, pipes, fittings and valves. Do not use tap water! Prior to sterilization, check sterilizing chamber to ensure there is sufficient feed water. No sterilization without feed water! WiseClave WAC Autoclaves have been designed for the following purposes; For sterilizing glassware, rubber items, pipette tips, instruments, filter bodies, as well as consumables, waste in bags, and to destroy infectious or septic materials. For sterilizing liquids, solutions and culture mediums in open or lightly closed vessels. For sterilizing foodstuffs For streaming liquids or for dissolving agar. For non-pressurized disinfection of heat-sensitive culture media and solutions. Liquids and foods must not be sterilized in pressure-sealed containers. Easily combustible or toxic liquids must no be sterilized The following products are not suitable for sterilization; Wooden items Bonded parts Plastic materials sensitive to hot water (e.g., screw tops) Electrical equipment Vessels or instruments made from steel or iron Metering equipment, unless their suitability for stream sterilization is specifically mentioned Destruction bags must be open during sterilization, otherwise they may burst. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 16/51

17 Before every sterilizing operation, check that the lid stiffener 2 on the lid 4 has moved all the way into the lid clamp 3. And check the lid screw handle 1 is turned until it cannot be turned anymore. Do not open sterilizing chamber until full sterilization operation cycle is finished. Allow chamber pressure gauge to slow zero before opening the autoclave. Watch for hot steam and hot water! Hot steam may escape when the lid is opened. The lid handle should only be gripped at the experiment end. Step back when opening the sterilizer. You must wear the following protective items when opening the sterilizing chamber and removing the sterilized articles; Apron Eye protectors Heat insulated gloves Watch for hot surfaces and hot steam! OPT sensor (SAFETY) knob should be set as operating temperature +20 ~ +30 C. Please be noted that the heater doesn t work if the knob is set to 0 position. When sterilizing liquids, do not fill vessels more than two-thirds full, as otherwise liquids may boil over. Do not sterilize pressure-sealed vessels. Explosion hazard! Watch for broken glasses! Never use for a explosive sample. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 17/51

18 After sterilizing liquids; Danger from retardation of boiling. For open vessels containing up to 1 liter: wait at least 2.5 hours For open vessels containing up to 2 liters: wait at least 3 hours Do not remove flasks or bags until the chamber temperature drops below 70 C. Do not hang onto or lean against the open lid. DO not climb onto the autoclave, as this may cause the autoclave to tilt. Please avoid ultrasonic lamps. The unit could be cracked or faded. Disconnect the power supply plug if the unit is not going to be used for an extended period of time. This Symbol indicates that this product is to be collected separately. The following apply only to users in European countries: This product is designated for separate collection at an appropriate collection point. Do not dispose of as household waste. This product is required to comply with the European Union s Waste Electrical & Electronic Equipment(WEEE) Directive 2002/96/EC DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 18/51

19 Controller Details Temp(Timer) SV Temp(Timer) PV Digital LCD with back-light : SV and PV of Temperature, SV and PV of Timer (Operation Timer and Delay Timer) are displayed. 19 MAIN mode button : Selection of main operation mode. (Set Operation Time mode, Set Temperature mode and Safety Locking mode) 20 SUB mode button : Selection of subsidiary operation mode. (Set Delay Time mode, Set Offset Temperature mode and Set Operation Cycle mode) 21 TIMER lamp : indication of Timer setting and status. 22 HEAT (Heating) lamp : indication of Heater setting and status. 23 Error lamp 24 Jog-shuttle knob : Turn + Push - Setting the value of Temperature or Timer by Turing. - Start and stop by Pushing. 25 Door Open Button DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 19/51

20 Operation 9 1. Preparation for Use DAIHAN Autoclave is a kind of Steam Sterilizer. So the user should fill water into the pressure vessel before operating the unit. (NOTE) Distilled water should be used. The user should pour water to the pressure vessel, so the bottom part of the vessel (bottom cover) should sink under the water. (NOTE) If the water level is too low, the machine cannot start sterilization operation by the functioning of water level sensor equipped in the vessel. (NOTE) Closing of manual ventilation valve 7 must be checked. (NOTE) Opening of valve 16 must be checked as well. This valve can be closed only for the diagnostic purpose by an authorized engineer. Connect the power cord to the proper power socket. (NOTE) If you bye WAC-80 or WAC-100, power consumption of the heater in the vessel is too high to use normal wall socket. So, a big 3-pole plug (for single-phase 230V AC with ground) 13 comes with power cord, and a socket with wiring connector 14 is supplied together as seen in the picture. You have to wire the power line of enough electric power to the connector 14 before plugging in order to use the machine. Turn on the Main Switch 11. At this moment, if the water level in the vessel is not sufficient, LCD shows Low-Level error message with buzzer sound. In this case, supply more water until you can see the normal status (Set Timer mode) on the LCD. (NOTE) Set the OPT sensor knob 15 to 20~30 C higher than operation temperature (eg., If your operating temperature would be 121 C, proper value of the OPT sensor would be 150 C). Please be noted that the temperature on the scale is rough values. 2. Preparation and Placing of Materials All materials autoclaved must be placed in an autoclavable tray (wire basket delivered together with machine) with sides that are at least 5 inches in height. The use of trays should eliminate anything boiling over and spilling into the autoclave. Therefore, all materials must fit within this tray. Only autoclavable materials may be placed in the autoclave. If you are unsure if something is autoclavable, check with the manufacturer. Liquids to be autoclaved must be in an autoclavable vessel that is at least twice as large as the volume to be autoclaved (i.e. If you are autoclaving 1 liter of media, you need to put it in a flask that hold at least 2 liters). This allows for boiling during the cycle. Caps DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 20/51

21 must be slightly loose so that pressure created during the cycle does not cause the vessel to break. For screw cap containers you can make the lid hand tight and then loosen the lid by one-half turn. Dry goods (solids) must be placed in an autoclavable tray with 5-inch sides also. Garbage must be put in autoclavable bags and inside the autoclavable trays with 5-inch sides. Sharps containers must also go into the same type of autoclavable trays. To ensure proper sterilization of both garbage and sharps containers, 1 liter of water should be added to the bags or sharps containers. This water will vaporize during the autoclave cycle to allow better penetration of steam and more efficient sterilization. Autoclave garbage bags must be tied off. (WARNING) Use of non-autoclavable trays and containers may result in injury to the user and damage to the equipment. After placing the material to be autoclaved, close the lid 4 of pressure vessel by turning the lid handle 1 clockwise until it cannot be turned anymore. 3. Preview of Controller Mode Transition By the simple combination of MAIN button 19, SUB button 20 and Jog-shuttle knob 24, WAC autoclave offers outstanding simple user-interface with maximum efficiency and convenience for controlling overall functions of the machine - Patent registered The following diagram briefly shows the overall mode transition mechanism; Power ON SUB Set Timer mode Set Delay Timer mode MAIN MAIN SUB MAIN Set Temperature mode Set Temperature Offset mode MAIN MAIN SUB Locking mode Set Operation Cycle mode MAIN DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 21/51

22 4. Set Operation Cycle Mode WiseClave WAC autoclaves offer two different operation cycles named SOLID cycle mode and LIQUID cycle mode. As the name implies, LIQUID cycle is for autoclaving liquids while the SOLID cycle is for autoclaving solid or dry materials. With SOLID cycle mode operation, steam is ventilated out quickly after the completion of sterilization. On the other hand, with LIQUID cycle mode, steam is ventilated out very slowly after sterilization. The following table shows you the difference of the two cycles and proper use; Type of Cycle SOLID or fast exhaust LIQUID of slow exhaust Appropriate Material Dry goods, glassware, etc. Liquids Description This cycle charges the chamber with steam and holds it at a set pressure and temperature for a set period of time. At the end of the cycle, a valve opens and the chamber rapidly returns to atmospheric pressure. This cycle prevents sterilized liquids from boiling. Steam is exhausted slowly at the end of the cycle, allowing the liquids (which will be super-heated) to cool. By pushing MODE button 19 and SUB button 20 sequentially, you can enter into the Set Operation Cycle mode. Factory default mode is SOLID cycle. By pushing jog-shuttle knob 24, you can change the cycle, which is toggled by pushing repeatedly. Cycle shown on the LCD currently is the selected operation cycle. 5. Setting Timer 5.1 Set Operation Timer The initial mode after power-on is Set Operation Timer mode. TIMER lamp 21 is blinking. (NOTE) Operation Time means the Sterilization time. This timer begins to run (count down) when the Temp PV (present temperature) reaches the Temp SV (set temperature). Tim SV on LCD indicates set value of operation timer and Tim PV indicates present value (remaining time) of the timer. (NOTE) Initial value (SV) of the timer is 00:00, which means infinite time. With zero value of Timer SV, the machine cannot start operation. Turn the Jog-shuttle knob 24 then SV and PV change together. SV can be set in 1 minute, and the maximum value is 99:59 (99 hours and 59 minutes). Set required time by turning the Jog Knob 24 and PUSH it to complete the timer setting. Then timer is started and TIMER lamp 21 is on. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 22/51

23 (NOTE) By pushing the jog-knob 24 with set value, the timer begins to operate but doesn t start actual counting before beginning sterilization. It counts down when the Temp PV (present temperature) reaches the Temp SV (set temperature) as mentioned above. The machine stops operation (heating) after the SV of timer has passed. 5.2 Set Delay Timer It turns to Set Delay Timer mode by pushing SUB button 20 in Set Operation Timer mode. TIMER lamp 21 is blinking. DTim SV on LCD indicates set value of delay timer and DTim PV indicates present value (remaining time) of the timer. Set required time using the Jog Knob 24 and push it to complete the timer setting. Then timer is started and TIMER lamp 21 is on. The machine starts operation (heating) after the SV of delay timer has passed. It returns to Set Operation Timer mode by pushing MAIN button (NOTE) While the machine is being operated already (by setting operation timer, temperature and heating start), delay timer operation cannot be set and started Set Temperature 6.1 Set Temperature It turns to Set Temperature mode by pushing MAIN button 19 in Set Operation Timer mode. HEAT lamp 22 is blinking. Temp SV on LCD indicates set value of operation temperature and Temp PV indicates present value (measured value by temperature sensor in the pressure vessel) of the temperature. Turn the Jog-shuttle knob 24 then SV changes. SV can be set with the resolution of 0.1 C. The maximum value is C and the minimum value is 25.0 C. Set required operating temperature by turning the Jog Knob 7 and PUSH it to complete the temperature setting. The controller starts operation of heater in order to reach the set temperature. HEAT lamp 22 is on. (NOTE) As mentioned in the section 5.1, the machine cannot start heating (sterilization) operation without setting the operation timer to non-zero value. 6.2 Temperature Offset WiseClave WAC autoclaves intelligently and precisely controls the temperature inside the pressure vessel by digital Fuzzy control system, so high precision with low over/undershoot is assured. But, some users want to synchronize the temperature PV of the machine to the temperature value measured by other thermometer that is used as a reference meter for the DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 23/51

24 whole experimental process. In such a case, WAC autoclaves offer a function of adjusting the temperature PV within 10.0 ~ C User s self-compensation function. It turns to Set Offset Value mode by pushing SUB button 20 in Set Temperature mode. Temp PV on LCD indicates current temperature and Offset indicates the value to be added to PV temperature (compensation value). Turn the Jog-shuttle knob 24 then Offset and Temp PV changes together. Offset can be set with the resolution of 0.1 C, and input range is 10.0 to C. Temp PV shows value added or subtracted by Offset value. It returns to Set Temperature mode by pushing MAIN button Locking Mode It turns to Locking mode by pushing MAIN button 19 in Set Temperature mode. In this mode, turning or pushing Jog knob doesn t work. So, you could prevent any changes of set values by mistake. Operation Timer PV and Temp PV are shown on LCD. It returns to Set Operation Timer mode by pushing MAIN button End of Sterilization When the set time has passed and the sterilization is finished, firstly heating is stopped, and then, the steam and pressure is exhausted out and the pressure is removed. User can identify this by buzzer sound for 30 seconds. As described in the section 4 of this chapter, the way of exhausting steam and pressure is different based on the operation cycle. In SOLID cycle mode, valve is opened completely and steam is discharged quickly. In LIQUID cycle mode, valve is not completely opened at a time. Firstly it waits for 5 minutes with valve closed after heater OFF. And then, the valve is opened during 3 seconds, after that the valve is closed again for 2 minutes, and then it reopens during 3 seconds, etc. This procedure repeats until the temperature comes down to 90 C (lasts approx. 30minutes), and then it waits until the temperature reaches down to 80 C with valve closed again. After that, the valve is closed completely. While steam is discharged out of the pressure vessel, the user cannot see the steam out. Steam in the vessel is converted into water by passing trough a specially designed steam condenser. This feature offers safety and convenience to the user. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 24/51

25 9. After Sterilization When the sterilization is completed, pressure is exhausted through steam discharging automatically. You could check it with the pressure gauge 5 next to control panel. After the pressure comes down to 0 ~ 0.2 kg/cm 2, you may open the lid by turning lid handle counterclockwise. If you want to confirm the complete ventilation of the steam and pressure, you may use the manual ventilation valve 7 at this moment. If you want to remove the water remained in the vessel, you could do it with the drain valve. User can open the door at the left side of the body, and can find the water drain valve 17 there. Connect a kind of tube to the valve and open it, then the water remained in the vessel can be poured out. 10. Storage Function In each setting mode (Set Operation Timer mode, Set Delay Timer mode, Set Temperature mode, Set Offset Value mode and Set Operation Cycle mode), you can store the current set values by simply pushing the Jog knob for 1 second. For showing the value is successfully stored, the set value on LCD blinks three times. Even though you turn off the machine, the set values are stored permanently, so you can re-use the values for the next time of operation. 11. 비상시 Lid 잠금장치해제방법 (Emergency Lid unlock method) 본기기는사용상의안전을위해전자식 Lid 잠금시스템이장착되어있습니다. 하여전원이공급되지않거나기기전원부의이상이있을경우 Lid를 Open버튼동작으로열수가없게됩니다. 이런경우다음과같은방법으로 Lid를열어주십시오. < 그림.3> 비상시 Lid잠금장치해제방법 과같이 Lid중심축부위에 Lid잠금해제홀이있습니다. 이곳홀에적당한사이즈의도구 ( 육각렌치등 ) 을삽입하십시오. 개폐장치가열리는소리를확인하고도구의삽입상태를유지한상태로 Lid를들어올리십시오. Lid를들어올리는힘을유지한채로도구를천천히빼면서 Lid를끝까지여십시오. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 25/51

26 Emergency Lid unlock method 적당한사이즈의도구 ( 육각렌치 ) 등을삽입하여개폐장치가열리는소리를확인한다. 도구의삽입상태를유지한상태로 Lid를들어올린다. *Lid를들어올리는힘을유지한상태로도구를천천히빼면서 Lid를끝까지연다. 그림.3> 비 < 그림.3> 비상시 Lid 잠금장치해제방법 DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 26/51

27 Specifications 10 Technical Information DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 27/51

28 Functional Block Diagram 11 DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 28/51

29 Maintenance If you don t use the device for a long time, please plug out, dry up the machine and keep with packing. 2. When you need exchange of a component for repair, you MUST use an original component provided by manufacturer. 3. In the warranty period specified on the warranty sheet included in this operation manual, breakdown of the machine in spite of normal/proper use will be treated by manufacturer or by an official agent of manufacturer. 4. The manufacturer or its agent is not in charge of breakdown caused by abnormal use or by ignoring the warnings and cautions described in this manual. 5. Before cleaning the machine, please be sure to pull the power cord off. 6. For cleaning of the machine, we recommend you to use neutral detergent and soft cloth. Do not use coarse cloth, strong chemicals or organic solution. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 29/51

30 Troubles and Solutions 13 Situation Confirmations and Solutions Power failure Check the power cord is plugged. Check the supplied electricity is proper and regulated. Check the Leakage breaker is ON. Not heating Check the temp SV and confirm the operation started by pushing Jog knob. Check the MAIN power switch is ON. Check the SAFETY knob is set to too lower value than recommended value and not set to 0. Heating but it doesn t reach the SV temperature Problem in the heater or temperature sensor. Please call technical service. Noise The noise could be generated by the fan equipped in the steam condenser. If it becomes too big, please call technical service. If you have any problem other than the above, please call technical service of manufacturer or an official agent. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 30/51

31 CERTIFICATE of Quality Tested by Manufacturer and Free Warranty up to 2 years for Laboratory Instrument Limited Warranty 1. This instrument has gone through our testing process about all functions before shipment. 2. This instrument is warranted for 2 years from purchasing date. 3. A breakdown caused by customer s improper use or natural disaster is excepted from this warranty. 4. This certification is only for international customers. Item Model No. Serial No. Date Customer WiseClave WAC, Autoclave (Steam Sterilizer) DAIHAN Scientific Co., Ltd. Daihan Bldg., 24-4, Sangwolgok-Dong Seongbuk-Gu, Seoul, KOREA, TEL: , Ext. 129 FAX: daihan@daihansci.co.kr DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 31/51

WiseBath WSB Shaking Water Bath Operation Manual (Version 1.4.0)

WiseBath WSB Shaking Water Bath Operation Manual (Version 1.4.0) WiseBath WSB Shaking Water Bath Operation Manual (Version 1.4.0) written for Model WSB-18/-30/-45 Contents Page 1. Safety Instructions........ 3 2. Before Use...... 8 3. Introduction... 9 4. Package Contents...

More information

Operation Manual (Version 1.4.4)

Operation Manual (Version 1.4.4) WiseTherm FP / FHP Digital Muffle Furnaces Certifications by - - - CE Marked Products. ISO 9001 Certified. PL Insurance. Validation(IQ&OQ) Service. Patented( No. 10-0554098) Jog Shuttle Control System.

More information

Operation Manual (Version 1.5.1)

Operation Manual (Version 1.5.1) VWR symphony TM Low-Temp./BOD Incubator Operation Manual (Version 1.5.1) VWR symphony Low-Temp./BOD Incubator 414004-626, 414004-628, 414004-630, 414004-632 414004-627, 414004-629, 414004-631, 414004-633

More information

Operation Manual. (Version 1.5.1)

Operation Manual. (Version 1.5.1) VWR symphony TM Gravity Convection General Incubator Operation Manual (Version 1.5.1) VWR symphony Gravity Convection General Incubator 414004-610, 414004-612, 414004-614, 414004-616 414004-611, 414004-613,

More information

Operation Manual. VWR Vacuum Ovens. (Version 2.0.0) VWR Vacuum Oven , , , ,

Operation Manual. VWR Vacuum Ovens. (Version 2.0.0) VWR Vacuum Oven , , , , VWR Vacuum Ovens Operation Manual (Version 2.0.0) VWR Vacuum Oven 10752-398, 10752-400, 10752-402 10752-404, 10752-354, 10752-356 10752-402 VWR Vacuum Oven, 30Lit. Man. V205 (10 Nov. 2015) Contents Page

More information

Owner s Manual Window Air Conditioner

Owner s Manual Window Air Conditioner Owner s Manual Window Air Conditioner G17-5MCVWAC1 G16-5MCVWAC Write the model and serial numbers below for your records: Model # Serial # Date Purchased Please read the entire manual carefully to ensure

More information

SX-300 SX-500 SX-700

SX-300 SX-500 SX-700 OPERATOR'S MANUAL AUTOCLAVE SX-300 SX-500 SX-700 Before starting operation, read this manual thoroughly for a complete understanding of the autoclave and its correct operation. Carefully store this operation

More information

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different. RADS-51J RADS-61J Owner s Manual Room Air Conditioner with R-410A Heat Controller, Inc. 15 16 Contact an authorized service technician for repair or maintenance of this unit. Contact an authorized installer

More information

Manual Page 1 of 8. Manual. Laboratory autoclave

Manual Page 1 of 8. Manual. Laboratory autoclave Manual 17.11.2014 Page 1 of 8 Manual Laboratory autoclave Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization, as an aid in research and development CertoClav

More information

Instruction Manual for Electric Ovens OO757X OO986X

Instruction Manual for Electric Ovens OO757X OO986X Instruction Manual for Electric Ovens OO757X OO986X 1 2 DEAR CUSTOMER, We thank you and congratulate you on your choice. This new carefully designed product, manufactured with the highest quality materials,

More information

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference. OWNER S MANUAL DEHUMIDIFIER ESPAÑOL FRANÇAIS Read this manual carefully before operating the appliance and retain it for future reference. Model : UD701KOG1 P/NO : MFL68026017 www.lg.com TABLE OF CONTENTS

More information

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

Manual v1 Page 1 of 19. Manual. Laboratory autoclave Manual 20.2.2015 v1 Page 1 of 19 Manual Laboratory autoclave Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization, as an aid in research and development CertoClav

More information

Forced Convection Constant Temperature Oven. Instruction Manual

Forced Convection Constant Temperature Oven. Instruction Manual Forced Convection Constant Temperature Oven Model DNE 400/40/600 60/80/90 Instruction Manual - Version 7 - Thank you for purchasing "Forced Convection Constant Temperature Oven, DNE Series" of Yamato Scientific

More information

ULTRA LOW TEMPERATURE FREEZER. User Manual

ULTRA LOW TEMPERATURE FREEZER. User Manual ULTRA LOW TEMPERATURE FREEZER User Manual Note:Kaltis reserves the right to modify any parts of this manual without prior notice. 1. No part of this manual may be reproduced in any form, or translated

More information

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd   Ph: Fax: INSTRUCTION MANUAL Laboratory Equipment Pty Ltd email: sales@labec.com.au Ph: 02 9560 2811 Fax: 02 9560 6131 www.labec.com.au 2014 Shaking Water Bath Instruction Manual Model : J-SWB19, J-SWB35, J-SWB60

More information

Moveable Air-conditioner User s Manual

Moveable Air-conditioner User s Manual Moveable Air-conditioner User s Manual For Model :KY-25F1,KYR-25F1 KY-35F1,KYR-35F1 Please read this user s manual carefully to ensure proper use, maintenance and installation FORWARD Portable air-conditioners

More information

Bona Portable DCS Manual and safety instructions

Bona Portable DCS Manual and safety instructions Manual and safety instructions TECHNICAL DATA Motor type: Voltage (+/- 10%): Frequency: Power: Fuses: Max Flow: Max under-pressure: Hose: Coarse filter: HEPA filter: Noise level: Bag hose system: Length/Wide/Height:

More information

DAIHAN New Generation New Steam Sterilizer, Digital Fuzzy Controlled Autoclave

DAIHAN New Generation New Steam Sterilizer, Digital Fuzzy Controlled Autoclave Maximum Convenience by Advanced Digital Technology DAIHAN New Generation New Steam Sterilizer, Digital Fuzzy Controlled Autoclave Safely! Perfectly! Innovative Upgrade MaXterile TM DAIHAN s new Autoclaves

More information

Dyna-Form Air. Alternating Pressure Relief Overlay System

Dyna-Form Air. Alternating Pressure Relief Overlay System Dyna-Form Air Alternating Pressure Relief Overlay System 1 Contents Introduction 3 Cleaning 10 General Warnings 4 Control Unit 10 Unpacking / Setting Up 5 Air Filter 10 Setting Up 6 Mattress Cover 11 Connect

More information

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: 79202-00 79202-05 79202-30 79202-35 Approval Agency s Model 79202-00 & 79202-05 Model 79202-30 & 79202-35 Not recommended for pumping acid,

More information

INSTRUCTIONS CertoClav EL

INSTRUCTIONS CertoClav EL High Pressure-LABORATORY AUTOCLAVE Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization As an aid in research and development Thermometer Lid handle with locking

More information

ENGLISH (Original instructions) INSTRUCTION MANUAL. Demolition Hammer HM0810TA DOUBLE INSULATION. IMPORTANT: Read Before Using.

ENGLISH (Original instructions) INSTRUCTION MANUAL. Demolition Hammer HM0810TA DOUBLE INSULATION. IMPORTANT: Read Before Using. ENGLISH (Original instructions) INSTRUCTION MANUAL Demolition Hammer HM080TA 00079 DOUBLE INSULATION IMPORTANT: Read Before Using. ENGLISH (Original instructions) SPECIFICATIONS Model HM080TA Blows per

More information

PolySprint. Operation Manual PSM-NIT-13004E. Follow this manual when using Nitta PolySprint Heat Press.

PolySprint. Operation Manual PSM-NIT-13004E. Follow this manual when using Nitta PolySprint Heat Press. PSM-NIT-13004E PolySprint Heat Press NPS-1205H1/H2 Operation Manual Follow this manual when using Nitta PolySprint Heat Press. Please pass this manual to PolySprint Heat Press users for a safe and trouble-free

More information

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 HG 675 X 60 HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 1 2 1. : 93/68: 90/396: 2006/95/CE: 2004/108/CE: - 1935/2004:. 2002/95/CE: RoHS 2.,.,,,,...,. (,..)..,,.,. ( ),,, ;,,.,.....,.,,,,,,...,. (..),,.,..,.,,,,

More information

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL ECONOMY VACUUM OVEN MODEL: 1407, 1407-2, 1408, & 1408-2 INSTALLATION AND INSTRUCTION MANUAL Sheldon Manufacturing Inc. P.O. Box 627, Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab

More information

Inverter Split-type Room Air Conditioner

Inverter Split-type Room Air Conditioner OWNER S MANUAL Inverter Split-type Room Air Conditioner Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.

More information

Air Paper Jogger AJ-700 Operation Manual. Keep this manual at hand where it can be referenced at any time.

Air Paper Jogger AJ-700 Operation Manual. Keep this manual at hand where it can be referenced at any time. Air Paper Jogger AJ-700 Operation Manual Keep this manual at hand where it can be referenced at any time. June 25, 2004 Introduction Thank you for purchasing this product. Please carefully read this Operation

More information

NON-DUCTED TYPE SMOKELESS BBQ ROASTER MODEL NJG-C

NON-DUCTED TYPE SMOKELESS BBQ ROASTER MODEL NJG-C OPERATION MANUAL NON-DUCTED TYPE SMOKELESS BBQ ROASTER MODEL NJG-C * Before operating this roaster unit, please read and understand the instructions specified in this manual for proper and safety use.

More information

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions Model No. GB-PAC-08E4 8,000 BTU Portable Air Conditioner Operating Instructions Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner. This owner s manual will provide you with valuable

More information

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified OPERATIONS MANUAL Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS-1001 Certified Contents 1. Safety 3 2. Introduction 7 3. Package Contents 7 4. Specifications 7 5. Features 8 6.

More information

INSTRUCTIONS AND WARRANTY

INSTRUCTIONS AND WARRANTY INSTRUCTIONS AND WARRANTY MODEL NO SI5288 SALTON FULL FUNCTION STEAM IRON Thank you for purchasing our SALTON Full Feature Iron. All SALTON appliances are manufactured with the strictest standards to ensure

More information

Sip Vacuum Cleaner 1400/35 Wet & Dry

Sip Vacuum Cleaner 1400/35 Wet & Dry Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

30-pint Dehumidifier User Guide

30-pint Dehumidifier User Guide 30-pint Dehumidifier User Guide IVADH30PW Thank you for purchasing the Ivation 30 Pint Dehumidifier. This User Guide is intended to provide you with guidelines to ensure that operation of this product

More information

Operating Manual "Mark II" Solid-State Digital Automatic Controlled Sterilizers

Operating Manual Mark II Solid-State Digital Automatic Controlled Sterilizers Operating Manual "Mark II" Solid-State Digital Automatic Controlled Sterilizers Rev. 070129 PLEASE READ CAREFULLY BEFORE ATTEMPTING TO OPERATE YOUR STERILIZER. Copyright: Consolidated Stills and Sterilizers

More information

INSTRUCTIONS AND WARRANTY

INSTRUCTIONS AND WARRANTY INSTRUCTIONS AND WARRANTY MODEL NO: STS80 SALTON HOT TRAY WITH TEMPERATURE CONTROL Congratulations on purchasing our Salton Hot Tray with Temperature Control. Each unit is manufactured to ensure safety

More information

Ionizer (Static Remover) STABLO-EX Instruction Manual

Ionizer (Static Remover) STABLO-EX Instruction Manual 321-56879-21E Jan. 2009 For Electronic Balances Ionizer (Static Remover) STABLO-EX Instruction Manual Read the instruction manual thoroughly before you use the product. Retain this instruction manual for

More information

Table of Contents. English

Table of Contents. English OM-E0799E 000 English Thank you for purchasing VIVA ace Motor Kit. Please read this Operation Manual and the VIVA ace Basic Set Operation Manual carefully before use for operating instructions and care

More information

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual VACUUM OVEN Model: VPX9-2 Installation and Operation Manual Sheldon Manufacturing, Inc. P.O. Box 627, 300 N 26 th Avenue, Cornelius, Oregon 97113 EMAIL: tech @ Shellab.com; www.shellab.com 1-800-322-4897

More information

Built in Electric Ceramic Hob. Instruction Manual

Built in Electric Ceramic Hob. Instruction Manual Built in Electric Ceramic Hob Instruction Manual Model number: RHEH1 Opening times: Monday - Friday 8am 6pm & Saturday 9am 1pm or visit us at Contents Safety Instructions 3-4 Before using the appliance

More information

TABLE OF CONTENTS FOR YOUR SAFETY

TABLE OF CONTENTS FOR YOUR SAFETY TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...2 2. OPERATION & FUNCTION OF PARTS...2, 3 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION REQUIREMENTS...3, 4 4. INSTALLATION

More information

Corning LSE Benchtop Shaking Incubator

Corning LSE Benchtop Shaking Incubator Corning LSE Benchtop Shaking Incubator INSTRUCTION MANUAL Models 6790 (120V US) 6791 (230V EU) Table of Contents 1.0. GENERAL INFORMATION GENERAL INFORMATION... 1 1.1 Definition... 1 1.2 Key features...

More information

Table of Contents DIGITAL DRYING OVEN. Features. Setup. Cautions. Description of the parts. Temperature Controls. Maintenance and Storage

Table of Contents DIGITAL DRYING OVEN. Features. Setup. Cautions. Description of the parts. Temperature Controls. Maintenance and Storage Table of Contents 1 Features 2 Setup 3 Cautions 4 Description of the parts 5 Temperature Controls 6 Maintenance and Storage 7 Troubleshooting 8 Warranty 9 Technical Specifications -2- Safety warnings Before

More information

Safety and Instruction Manual

Safety and Instruction Manual T14002 Safety and Instruction Manual PLEASE READ CAREFULLY 30cm Ceramic Coated Electric Sauté Pan T14002 30cm Ceramic Coated Electric Sauté Pan TECHNICAL DATA Description: Model: Rated Voltage: Input power:

More information

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Mobile Air Conditioner Instruction Manual Model TC-N9KM Mobile Air Conditioner Instruction Manual Model TC-N9KM Please read and retain these instructions for future reference SPECIFICATION Model no. Cooling capacity Power/Ampere consumption for cooling* Air

More information

INSTRUCTIONS AND WARRANTY

INSTRUCTIONS AND WARRANTY INSTRUCTIONS AND WARRANTY MODEL: SB400E SALTON 450W STAINLESS STEEL GLASS JUG BLENDER Congratulations on purchasing our Salton 450W Stainless Steel Glass Jug Blender. Each unit is manufactured to ensure

More information

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL.   Please read this manual carefully before operating your set and retain it for future reference. ENGLISH OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. Ceiling Suspended Original instruction ARNU18GV1A4 ARNU24GV1A4 ARNU36GV2A4

More information

ENGLISH (Original instructions) INSTRUCTION MANUAL. Belt Sander DOUBLE INSULATION. IMPORTANT: Read Before Using.

ENGLISH (Original instructions) INSTRUCTION MANUAL. Belt Sander DOUBLE INSULATION. IMPORTANT: Read Before Using. ENGLISH (Original instructions) INSTRUCTION MANUAL Belt Sander 990 99 00336 DOUBLE INSULATION IMPORTANT: Read Before Using. ENGLISH (Original instructions) SPECIFICATIONS Model 990 99 Belt size 76 mm x

More information

English... 5 Čeština Slovenčina Magyarul Polski Русский... 85

English... 5 Čeština Slovenčina Magyarul Polski Русский... 85 FDS 10150-A 2 English... 5 Čeština... 21 Slovenčina... 37 Magyarul... 53 Polski... 69 Русский... 85 1 FDS 10150-A 4 FDS 10150-A Contents 5 EN Screwdriver INSTRUCTION MANUAL Thank you for your purchase

More information

MODEL 7000 SUCTION UNIT

MODEL 7000 SUCTION UNIT MODEL 7000 SUCTION UNIT OPERATOR S MANUAL Caution Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by the law of the State in which he practices

More information

CONTENT. Precautions to Avoid Possible Exposure to Excessive Microwave Energy.. Important Safeguards... Control Panel...

CONTENT. Precautions to Avoid Possible Exposure to Excessive Microwave Energy.. Important Safeguards... Control Panel... MODEL:EMO-F2073(WH) CONTENT Precautions to Avoid Possible Exposure to Excessive Microwave Energy.. Important Safeguards... Part Name Control Panel... Installation of the Microwave Oven...... Grounding

More information

Product Manual Glue Applicators MS 80 and MS 200

Product Manual Glue Applicators MS 80 and MS 200 Product Manual www.pakarte.com Glue Applicators MS 80 and MS 00 Translation from German to English Table of Contents Product Description General Safety Instructions Safety Measures to be taken during Operation

More information

CTA15-2 warming drawer. operating and installation instructions

CTA15-2 warming drawer. operating and installation instructions CTA15-2 warming drawer operating and installation instructions Table of Contents GB-IE 1 PRECAUTIONS FOR USE...4 2 DISPOSAL INSTRUCTIONS - OUR ENVIRONMENT POLICY...5 3 SAFETY PRECAUTIONS...6 4 GET TO KNOW

More information

Model:DKG610(V)/650(V) Model:DKG810(V)/850(V)

Model:DKG610(V)/650(V) Model:DKG810(V)/850(V) Rapid Heating / Cooling Oven Model:DKG610(V)/650(V) Model:DKG810(V)/850(V) Instruction Manual Second Version Thank you very much for purchasing this Yamato DKG Series. Please read the Operating Instructions

More information

GDDEM10 DEHUMIDIFIER

GDDEM10 DEHUMIDIFIER GDDEM10 DEHUMIDIFIER SOCIABLE REMARK When using this dehumidifier in the European countries, the following information must be followed: DISPOSAL: Do not dispose this product as unsorted municipal waste.

More information

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA Operating Instructions High Performance Refrigerator PR-L2466W- PA PR-L2466W-PA Please read these instructions carefully before using this product, and save this manual for future use. See page 11 for

More information

INDUCTION COOKER User Guide

INDUCTION COOKER User Guide EN INDUCTION COOKER User Guide www.tefal.com C A D B L E M N F G H I J K IMPORTANT SAFETY INSTRUCTIONS Read these instructions for use carefully before using your appliance for the first time and keep

More information

Read these instructions before using and keep them available at all times!

Read these instructions before using and keep them available at all times! 200065 V2/0614 GB/UK ENGLISH Translation of the original instruction manual Read these instructions before using and keep them available at all times! 1. General information... 16 1.1 Information about

More information

3. To protect against electric shock, do not immerse cord, plugs, or machine in water or other liquid.

3. To protect against electric shock, do not immerse cord, plugs, or machine in water or other liquid. 1 IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and/or injury to persons, including the following:

More information

INSTRUCTIONS AND WARRANTY

INSTRUCTIONS AND WARRANTY INSTRUCTIONS AND WARRANTY MODEL NO. SPF40E SALTON ELITE PEDESTAL FAN 40CM Congratulations on purchasing our Salton Elite Pedestal Fan. Each unit is manufactured to ensure safety and reliability. Before

More information

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94 OPERATION MANUAL StableTemp Economy Mechanical Convection Oven Model : 52412-89,-90,-91,-92,-93,-94 This operation manual describes the important subjects on maintaining the product s functions, safety,

More information

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F. Instruction Manual Automatic Dispensing Hot Water Pot with Multi-temperature Function Automatic Dispensing One-Touch Dispense FEATURES Reboil Function 5 Temperature Settings Image Of SP-5016 208 F For

More information

- 1 - Updated on 18 March, 2010

- 1 - Updated on 18 March, 2010 - 1 - Updated on 18 March, 2010 TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...3 2. OPERATION & FUNCTION OF PARTS...4, 5 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION

More information

Autoclaves. Steam Autoclaves

Autoclaves. Steam Autoclaves Autoclaves Steris (PSC 545, 645, Kell 445) Amsco Steam autoclaves (NSC 484, Kell 445) Sanyo (PSC 645, NSC 484, Kell 445) Hiroyama Electric Autoclaves (PSC 545, 651) Dishwashers (PSC 545, 645, 745, NSC

More information

Magnetic Stirring Systems with Heat

Magnetic Stirring Systems with Heat Sharing your passion for making jewelry. Products. Service. Know-how. Magnetic Stirring Systems with Heat 335-212 Digital Ceramic Magnetic Stirring System with Heated Stand 335-211 Ceramic Magnetic Stirring

More information

Bona DCS70/Portable DCS Manual and safety instruction

Bona DCS70/Portable DCS Manual and safety instruction Bona DCS70/Portable DCS Manual and safety instruction WARNING Read the instructions manual before using the machine AMO530002 AMO530005 Bruksanvisning i original v1.1 TECHNICAL DATA Motor type: DCS70 Portable

More information

Electric Salamander CHM-1200W CHM-2400W CHM-4350W. User s Manual

Electric Salamander CHM-1200W CHM-2400W CHM-4350W. User s Manual Electric Salamander CHM-1200W CHM-2400W CHM-4350W User s Manual 1 Dear Client & User, Thank you for choosing our products. All the information and instructions in this manual take into account standard

More information

Instructions for Use Warming Drawer. Bedienungsanweisung Wärmeschublade. Notice d'utilisation Chauffe-vaisselle. Gebruiksaanwijzing Servieswarmer

Instructions for Use Warming Drawer. Bedienungsanweisung Wärmeschublade. Notice d'utilisation Chauffe-vaisselle. Gebruiksaanwijzing Servieswarmer Instructions for Use Warming Drawer Bedienungsanweisung Wärmeschublade Notice d'utilisation Chauffe-vaisselle Gebruiksaanwijzing Servieswarmer Table of Contents GB-IE 1 PRECAUTIONS FOR USE...4 2 DISPOSAL

More information

Read these instructions before using and keep them available at all times!

Read these instructions before using and keep them available at all times! Rimi 700220 V3/0214 GB/UK ENGLISH Translation of the original instruction manual Read these instructions before using and keep them available at all times! 1. General information... 18 1.1 Information

More information

Far-infrared Oil Heater Owner's manual

Far-infrared Oil Heater Owner's manual 16 Appearance and/or specifications of product can be changed for better quality and preference without prior notice ar-infrared Oil Heater Owner's manual 1 URRENT TEMP EMPTY UEL TARGET TEMP ALARM Heating

More information

DOC JAN06 LT 200

DOC JAN06 LT 200 DOC022.98.00742.JAN06 LT 200 DOC022.98.00742.JAN06 Thermostat LT 200 USER MANUAL (english) January 2006, Edition 2 Hach Lange GmbH, 2006. All rights reserved. Printed in Germany. CK/SK 42 Table of Contents

More information

Instruction Manual Suppository Penetration Tester. Type PM 30

Instruction Manual Suppository Penetration Tester. Type PM 30 Instruction Manual Suppository Penetration Tester Type PM 30 ERWEKA GmbH * Ottostr. 20 22 * 63150 Heusenstamm * Germany * Tel: +49 (0) 6104 6903-0 Fax: +49 (0) 6104 6903-40 * E-mail: info@erweka.com *

More information

Operations Manual. Part Number: For Research Use Only

Operations Manual. Part Number: For Research Use Only Operations Manual Part Number: 470230-598 For Research Use Only Ph: 1-800-962-2660 - Web: www.wardsci.com Thank you for choosing our Bench top sterilizers. Prior to operating this instrument, please read

More information

3 in 1 Garden Vacuum 9255 Instructions for Use

3 in 1 Garden Vacuum 9255 Instructions for Use Leaf Blower-Vac/Patio Cleaner Technical Specifications Model GY 8113 Rated voltage 230V Rated frequency 50Hz Rated power consumption 3000W Mains fuse(delayed action) 13A Speed 15000 rpm Max. blower air

More information

6L PRESSURE COOKER. Instruction Manual. Model: PLA1424

6L PRESSURE COOKER. Instruction Manual. Model: PLA1424 6L PRESSURE COOKER Instruction Manual Model: PLA1424 Due to ongoing product improvements, specifications and accessories may change without notice. Actual product may differ slightly to that depicted.

More information

SHORT WAVE INFRARED PANEL DRYER

SHORT WAVE INFRARED PANEL DRYER INSTRUCTIONS FOR: SHORT WAVE INFRARED PANEL DRYER MODEL: IR3000 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and

More information

Operator s Manual S-333. Automated Soil Compactor. Version 3.3. Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA USA

Operator s Manual S-333. Automated Soil Compactor. Version 3.3. Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA USA Automated Soil Compactor S-333 Operator s Manual Version 3.3 Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA 30087 USA Phone: 800-837-0864 or +1.770.465.7557 Fax: 770.465.7447 e-mail:

More information

Operation Manual RANGE HOOD

Operation Manual RANGE HOOD Operation Manual RANGE HOOD MODEL: BUF-03A TABLE OF CONTENTS Safety Instructions... 2 Name of Parts... 4 How to Use... 5 Operating the Range Hood... 5 Care and Maintenance... 6 Disassembling... 7 Cleaning...

More information

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING Thank you for choosing the Biomega BioClave steam sterilizer. Your steam sterilizer has been CE certified and designed with durability, reliability, and safety in mind. It is your responsibility to install

More information

Operating Instructions

Operating Instructions Operating Instructions Contents: TAIJI HOTCABI HC-12UVe Towel Warmer 1. Introduction 2. General description and operating principal 3. Precautions for safety use 4. Names of parts 5. Inspection and preparations

More information

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner _'_j_ii_yg, CI_ ' _i_,_!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP 12,000 BTU Portable Air Conditioner Operatin! nstructions Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner.

More information

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance MW001 Integrated Dishwasher Manual for Installation, Use and Maintenance Important The CDA Group Ltd cannot be held responsible for injuries or losses caused by incorrect use or installation of this product.

More information

Washing Machine OWNER S MANUAL TRWTL-70. Before using your washing machine, please read this manual carefully and keep it for future reference.

Washing Machine OWNER S MANUAL TRWTL-70. Before using your washing machine, please read this manual carefully and keep it for future reference. Before using your washing machine, please read this manual carefully and keep it for future reference. Washing Machine OWNER S MANUAL TRWTL-70 Read This Manual Inside you will find many helpful hints on

More information

INSTRUCTIONS AND WARRANTY

INSTRUCTIONS AND WARRANTY INSTRUCTIONS AND WARRANTY RHI613 RUSSELL HOBBS STEAM, SPRAY, DRY IRON Congratulations on purchasing our Russell Hobbs Steam, Spray, Dry Iron. Each unit is manufactured to ensure safety and reliability.

More information

- 1 - Updated on 18 March, 2010

- 1 - Updated on 18 March, 2010 - 1 - Updated on 18 March, 2010 TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...3 2. OPERATION & FUNCTION OF PARTS...4, 5 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION

More information

TAIJI HOTCABI Towel Warmer

TAIJI HOTCABI Towel Warmer INSTRUCTION MANUAL TAIJI HOTCABI Towel Warmer Model: HC-38, HC-38UV Table of Contents: 1. Safety Precautions 2~5 2. Purpose of Use 6 3. Operational Mechanism 6 4. Parts Identification 6 5. Prior to use

More information

TECHNOSKLO Ltd. Držkov

TECHNOSKLO Ltd. Držkov TECHNOSKLO Ltd. Držkov Distillation apparatus for producing of distilled water TYPE DP 4000 Operating manual TECHNOSKLO Ltd. 468 24 Držkov 135 Czech Republic tel.: 00420 483 346 403 fax: 00420 483 385

More information

* depending on model.

* depending on model. EN EASY PRESSING * * depending on model www.tefal.com 1 2 3 4 5 7* 8 9 10 11 6 12 14* 13* 15 * * depending on model Click!! Click!! fig. 1 fig. 2 fig. 3 fig. 4 fig. 5 fig. 6 fig. 7 fig. 8 fig. 9 ¾ fig.

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL ECONOMY OVENS SMO1E SMO3E MODELS OBSOLETED AFTER MAY 31ST SMO1E-2, SMO3E-2, SMO5E, SOM5E-2 INSTALLATION AND OPERATION MANUAL Revised June 13, 2017 861659 Sheldon Manufacturing Inc. P.O. Box 627 Cornelius,

More information

BL Series INSTRUCTIONS

BL Series INSTRUCTIONS BL Series Models: EX5204/BL514 EX5204/BL515 EX5214/BL524 EX5214/BL525 EXT5214/BL524 EXT5214/BL525 EX5404/BL614 EX5404/BL615 EX5414/BL624 EX5414/BL625 EXT5214H/BL528 EXT5214H/BL529 Automatic Backlatcher

More information

INSTRUCTIONS AND WARRANTY

INSTRUCTIONS AND WARRANTY INSTRUCTIONS AND WARRANTY RHIS258 RUSSELL HOBBS PRO PRECISION STEAM STATION Congratulations on purchasing our Russell Hobbs Pro Precision Steam Station. Each unit is manufactured to ensure safety and reliability.

More information

ASPIRE Laboratory Aspirator

ASPIRE Laboratory Aspirator ASPIRE Laboratory Aspirator USER MANUAL Rev 2/14/18 Accuris Instruments / Benchmark Scientific Ph: (908) 769-5555 E-mail: info@accuris-usa.com (C) Benchmark Scientific, 2018 THE ACCURIS ASPIRE LABORATORY

More information

TM585. Refrigerator - Freezer Operation manual. Contents

TM585. Refrigerator - Freezer Operation manual. Contents TM585 Refrigerator - Freezer Operation manual Contents Safety information..... 3 Installation................................. 5 Description.... 6 Useful modes.... 7 Control panel.... 8 Storing food....

More information

Instruction Manual Item No.: V~, 60Hz

Instruction Manual Item No.: V~, 60Hz Energy- Saving Mode Portable AC 8,000 BTU Model: MW-O-08C Montgomery Ward Customer Service 1112 7th Avenue, Monroe, WI 53566 8:00 am to Midnight, Monday through Friday Wards.com 1 888 557 3848 Instruction

More information

CRISTAL Built-in Dish Sterilizer Instruction Manual

CRISTAL Built-in Dish Sterilizer Instruction Manual CRISTAL Built-in Dish Sterilizer Instruction Manual Model No.: D36DSS Version Number: 01 Revision Date: September 2014 Dear user: Thank you for your purchase of CRISTAL built-in dish sterilizer! Please

More information

ENGLISH (Original instructions) INSTRUCTION MANUAL. Power Mixer UT2204 DOUBLE INSULATION. IMPORTANT: Read Before Using.

ENGLISH (Original instructions) INSTRUCTION MANUAL. Power Mixer UT2204 DOUBLE INSULATION. IMPORTANT: Read Before Using. ENGLISH (Original instructions) INSTRUCTION MANUAL Power Mixer UT04 0078 DOUBLE INSULATION IMPORTANT: Read Before Using. ENGLISH (Original instructions) SPECIFICATIONS Model UT04 No load speed (min - )

More information

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Hand Held Steamer DF-A001 User Manual

Hand Held Steamer DF-A001 User Manual Hand Held Steamer DF-A001 User Manual PLEASE READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE Contents: Technical data Important safety instructions Description of the appliance Accessories Operation

More information

Seaward Products. OWNER S MANUAL Installation Operation - Maintenance. Princess Gourmet Model 345. Built-in Electric Oven ELECTRIC WALL OVEN

Seaward Products. OWNER S MANUAL Installation Operation - Maintenance. Princess Gourmet Model 345. Built-in Electric Oven ELECTRIC WALL OVEN Seaward Products ELECTRIC WALL OVEN OWNER S MANUAL Installation Operation - Maintenance Princess Gourmet Model 345 Built-in Electric Oven IMPORTANT: Read all instructions before operating Oven. Save the

More information

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual PT0E-0922 Portable Oxygen Monitor OX-07 (Type B) Operating Manual Request for the Customers Read and understand this operating manual before using this gas monitor. Use it in accordance

More information