Far-infrared Oil Heater Owner's manual

Size: px
Start display at page:

Download "Far-infrared Oil Heater Owner's manual"

Transcription

1 16 Appearance and/or specifications of product can be changed for better quality and preference without prior notice ar-infrared Oil Heater Owner's manual 1

2 URRENT TEMP EMPTY UEL TARGET TEMP ALARM Heating O R BLOWER TEMP. SET SET POWER TEMP BLOWER O R M H Table of contents eatures 02 Names of each component (ront) 03 Names of each component (Inside of Right) 04 How to use correctly 05 Safety cautions 06 Items to check before use 07 autions during use 08 Routine check / Periodic check 09 How to install the product 10 Electrical wiring diagram 11 Items to check before requesting service 12 General specifications 14 Limited warranty 15 eatures Heating method using principle of the radiation enables to transmit heat to specific objects or people directly instead of heating air in the room. It transmits heat far from the heater and is ideal for open area. 1. ar-infrared radiation heat - Unique straightness of wavelength enables to provide spot heating to specific area. - It provide cleaner heating because it is radiation heating - The heat emits far-infrared radiation and anions that are good for refreshing and relaxing your body. - It reduced heating time innovatively. 2. Smell of fuel removal device - It reduced smell of fuel by collecting remaining fuel dramatically. 3. Dual side heating - ront and rear dual heating is available (protection grill can be purchased separately) 4. Various safety functions (Displaying current temperature, Off-timer, High performance burner, Low noise, High performance, Displaying rest of fuel, Lack of fuel alarm, Automatic air purge) 2

3 Names of each component ront Exhanst port Top grill ontrol (Operation panel) Heater tupe (Heat exchanger) compustion furnace Protection grill astors 3

4 Names of each component Inside of Right ontrol Overheat protector Burner Ignition trans Ignite using high pressure discharge Burner motor Air regulator Electronic pump Discharge the fuel at high pressure Air purge screw Turn this screw to the left to purge the air inside the fuel pipe Anti-collapse switch uel gauge uel filter uel injection port Temperature sensor 4

5 How to use correctly SET TEMP O R 1) Plug the power cord. urrent temperature is displayed. 2) If you press the Power button, TEMP SET or SET will be displayed. Please restart if E1 error occurs when starting the heater for the first time. Automatic air purge is accomplished. If you try purge the air manually, turn the air purge screw to the left 3 round then push the power button. You will hear beep sound. In 4 seconds close the air purge screw. 3) Select the Temp or Time setting by pressing TEMP SET or SET button. TEMP SET 4) Set the temperature or time using the Up/Down button. hanged by 1 between 0 ~40 - Heater will operate when set temperature is TEMP SET higher than current temperature. SET You can set time in the unit of 5 minutes between 10 and 25 minutes. 5) Heater is activated when the combustion lamp is turned on 8 seconds after the burner motor is activated. Heater will stop if the current temperature is 1 higher than setting temperature or reach to the set time. 6) To stop the heater, press the Power button. - Burner motor will stop in 5 minutes after combustion stop. - Only the current temperature will be displayed and set temperature will disappear. - Never turn off by unplugging the power cord. Burner may be damaged. 7) Off timer : If you press the Off timer, setting time will be displayed on urrent temp and Target temp/time display and Off timer will blank. Set the figure by pressing Up/Down button (1 hour unit) and press the Off timer button. Then Off timer lamp will be on and Off timer will start. If you press Off timer button again Off timer will be released with the lamp off. You may smell something burning during the initial operation. It indicates that the foreign substances are burnt inside the gasket. However this smell will disappear after 1 or 2 hours operation. If the fuel is lack, green lamp of fuel gauge will be off and red lamp will be on together with beep sound. Make sure to refuel after turning off the heater. 8) hange from to or to by pressing / button. Heater is activated by sensing the indoor temperature (range of temp set : 0 ~40 ) Heater start to operate and operation is stopped at set time every 30 minutes (you can set time in the unit of 5 minutes between 10 and 25 minutes) or example, if you set the time to 20, heater will operate for 20 minutes and stop for 10 minutes and repeat this cycle - TEMP SET lamp will off when you choose SET. 5

6 Safety autions Pay careful attention to the following warning signs intended to prevent the accidents resulted from the incorrect use. Danger Warning aution This danger sign warns you of serious injury or death expected when violating the safety rules or instructions. This warning sign warns you of serious injury or death expected when violating the safety rules or instructions. This caution sign warns you of injury or product damage expected when violating the safety rules or instructions Information to observe General prohibition Danger Warning and aution No touch Do not use fire onnect ground wire Warning It is very hot when the heater is under operation, so do not allow children to touch or hang Make sure to install the flue tube and vent prior to using the heater in the indoor area. - Material of flue tube should be stainless steel. Length of flue tube must not exceed 4 meters and number of bend must not exceed 2. Never move when the heater is under operation. If the heater falls down, it may cause fire. Stop operation when fill the fuel. This product is designed for space heating purpose only. We are not responsible for the trouble or accidents resulted from the other uses such as cooking or dry and/or any modification. Do not put any inflammable substances within 3 meters from the heater. autions Only use the fuel stated in the nameplate. Be careful not to let the fuel overflow by watching scale of flow meter. Open the window once or twice every hour for ventilation when the heater is operating for a long time. lean the heat reflecting plate not to be dirty with dust. If dust is deposited on the bottom of heat reflecting plate, it may cause fire or deformation. When the heater is used outdoor area, protect it from rain or snow and lock the castors before use. Please use proper electricity referring label on the heater. Store the heater with cover. Use the heater only after completely cleaning dust or dirt on the bottom. Do not leave the containers such as kettle on the exhaust port of the heater. It may cause damage to heater and bottom of container may be smoked. 6

7 ALARM Heating O R BLOWER TEMP. SET SET EMPTY UEL POWER BLOWER URRENT TEMP TARGET TEMP M ALARM Heating O R BLOWER TEMP. SET SET EMPTY UEL POWER TEMP BLOWER O R URRENT TEMP TARGET TEMP TEMP O R H M H URRENT TEMP EMPTY UEL TARGET TEMP ALARM Heating O R BLOWER TEMP. SET SET POWER TEMP BLOWER O R M H Items to check before use Warning : heck if there are any inflammable substances Get any inflammable substances like gasoline, kerosene, thinner away around from the heater. No inflammable substances around the heater! heck power supply Make sure power supply is 220~240V - Improper power supply may cause trouble. A220V heck voltage of power supply heck fuel Make sure fuel is disel. - Improper fuel may cause trouble. heck fuel is diesel. Gasoline kerosene thinner Gasoline Diesel heck castors lock Make sure to lock the castors not to move easily before using. 7

8 URRENT TEMP EMPTY UEL TARGET TEMP ALARM Heating O R BLOWER TEMP. SET SET POWER TEMP BLOWER O R M H URRENT TEMP EMPTY UEL TARGET TEMP ALARM Heating O R BLOWER TEMP. SET SET POWER URRENT TEMP EMPTY UEL TARGET TEMP ALARM Heating O R BLOWER TEMP. SET SET POWER TEMP BLOWER O R M H TEMP BLOWER O R M H autions during use aution : Ventilation Open the window once or twice every hour for ventilation when heater is used in closed area. - It may cause lack of oxygen if heater is operated for a long time without ventilation. Ventilation is necessary for indoor usage aution : Away from hildren It is very hot when the heater is under operation, so do not allow children to touch or hang. - hildren may be hurt. Take care of children aution : No foreign substances Do not put any foreign substances inside heater. - It may cause trouble or fire. Do not put any foreign substances inside heater. 8

9 Routine check / Periodic check aution : Routine check Make sure to check or clean only after the combustion of heater is stopped. heck if the fuel tank leaks heck if the combustion furnace or heating tube is corrupt or damaged. If the dust is deposited on heat reflecting plate, completely remove or clean the dust. heck if soot occurs in the exhaust port. The burner is adjusted to be suitable for the performance of heater. Avoid the unauthorized modification of adjustment. If you inevitably need to adjust the burner, consult with the agency where you purchased the heater or service center. aution : Routine check Make sure to clean the heater with cloth wet by neutral detergent or dry cloth only after the heater is completely cooled with the power plug unplugged. If you clean the heater with water, it may cause electric shock or damage to the product. aution : Periodic check ombustion furnace and Heater tube (heat exchanger) : heck if there is any soot once a year and clean it if there is. Bottom heat reflecting plate : heck if there is any corruption or dirt once a year and clean it if it is dirty. Replace if it is severely corrupted. uel filter (Inside fuel tank) : heck visually if there is any corruption once a year and replace if it is corrupted. astors : heck damage or installation once a month. If there is problem, fix it. 9

10 How to install the product Install the heater in the flat area. If you install the heater in sloped area, combustion furnace may be damaged by the irregular combustion. Install the flue tube for the indoor use. If the flue tube passes through the inflammable wall, wrap the inside wall more than 3cm with nonflammable insulation. Use stainless steel tube (75mm diameter) for the flue tube. Length of tube must be shorter than 4m and number of bent must not exceed 2. If the number of bent is more than 2 or when the length of tube is longer than 4m, it may cause incomplete combustion. More than 30m from the ceiling Slopped More then 10m Nonflammable insulation More then 30m (Example of flue tube installation) 10

11 Electrical Wiring Diagram Yellow Brown Green Black Red Black an Motor Ignition Trans Electronic pump Phototube Burner Gray2P Temperature Sensor Black2P low Meter Green Green Inversion Switch Yellow Yellow Overheat Sensor Black Black Green White A250V/5A A220V Black 11

12 Items to check before requesting service arry out remedy refer to the following instructions. Please request service when problem continue. Display Possible cause heck and remedy E1. No ignition Burner is not ignited - Lack of fuel - uel pipe is filled with air ( Drain the air) - Phototube is contaminated ( lean the phototube) E2. Phototube - Phototube error - Residual flame is detected. - heck if the phototube is loose ( ix the phototube) Phototube is defective ( Replace the phototube) - This phenomenon may occur when turning off the heater right after the combustion ( irmly connect temperature sensor) E3. Temperature sensor Temperature sensor trouble - heck if the temperature sensor connector is loose ( irmly connect temperature sensor) E4. Overheat sensor Product is overheated - heck if there is any burnt sign inside the burner ( Request service) - heck if overheat protector wire is disconnected ( Operate the heater again after connecting the wire) E5. Tilt Heater is tilted - Tilt error may occur when the heater is shaken or moved ( Operate the heater again) - Inversion switch wire is disconnected ( Operate the heater again after connecting the wire) E6. Lack of fuel No fuel - Refuel and operate the heater again Hi Temperature is over 50 degree - heck if the temperature sensor is installed inside ( Install the sensor outside) When E1~E6 error occur, check the reason of error and carry out remedy. Then restart the heater by pressing power button 2 times. 12

13 Items to check before requesting service If following problem occur please carry out remedy referring the table below. Request service if problem continues. Symptom Possible reason/heck Remedy All lamps are off on the operation panel - Power interruption - Unplugging - Blown fuse - onnect Power - Replace fuse Repeat on and off - Time set is selected (check the lamp) - Select Temp set Heater is operating but uel gauge lamp is off - uel gauge wire is disconnected - onnect the wire Burning smells during the initial operation - oreign substances are burnt inside the gasket - No action is needed. It will disappear after 1 ~ 2 hours Severe fuel smell - Smells when turning off the heater right after starting the heater - Dropping fuel when refueling - Keep operation more than 15 minutes - Remove the dropped fuel Room temperature on display is higher than normal - heck location of temperature sensor on rear of the heater (It may occur if the sensor is installed inside) - Locate the sensor at the correct position. 13

14 General specifications Item Model WHO-095 WHO-115 WHO-135 uel Diesel Diesel Diesel uel onsumption 0.9l/h 1.2l/h 1.3l/h Heating capacity 9,000Kcal/h 11,000Kcal/h 13,000Kcal/h Usage Space heating Space heating Space heating Electrical supply A 220V/50Hz A 220V/50Hz A 220V/50Hz Power conscomption 40W 40W 40W Dimension(W D H) mm mm Weight (Kg) 40Kg 40Kg 58Kg uel tank capacity 30l 30l 40l Item Model WHO-155 WHO-175 WHO-205 uel uel onsumption Heating capacity Usage Electrical supply Power conscomption Dimension(W D H) Weight (Kg) uel tank capacity Diesel Diesel Diesel 1.5l/h 1.9l/h 2.2l/h 15,000Kcal/h 17,000Kcal/h 20,000Kcal/h Space heating Space heating Space heating A 220V/50Hz A 220V/50Hz A 220V/50Hz 40W 60W 60W mm mm mm 58Kg 63Kg 63Kg 45l 45l 45l Specifications can be changed for better quality and performance without prior notice. 14

15 Limited Warranty Make sure to fill in the following blanks upon sale of product: Product Name Date of purchase ar-infrared tube heater Model No. Warranty period 1 year from the date of purchase User Address: Name: Phone No. : Shop Address (Shop name): Name: Phone No. : This product has been produced under the strict quality control. We guarantee the quality of this product. The product is exchanged or repaired, and you will get a refund in accordance with the consumers' damage compensation regulations. We will provide the free repair service during the warranty period. We will repair the defective product at actual cost after the warranty period. What this warranty does not cover: 1. Defect or trouble resulted from the customers' carelessness 2. Defect or trouble resulting from disasters such as flood, fire and lightning stroke 3. Defect or trouble resulted from the unauthorized repair or modification 4. Defect or trouble resulted from the use of unauthorized power 5. Defect or trouble resulted from the wrong installation 6. Defect or trouble resulted from the use of other fuels besides the designated fuel. WELTEM O., LTD. Manufacturer 118, Jayumuyeok 3-gil, Masanhoewon-gu, hangwon-ity, Gyeongsangnam-do, Korea TEL: (055) (main phone No.) AX: (055)

16 118, Jayumuyeok 3-gil, Masanhoewon-gu, hangwon-ity, Gyeongsangnam-do, Korea TEL: (ext.2) AX:

FAR INFRARED RAYS HEATER

FAR INFRARED RAYS HEATER FAR INFRARED RAYS HEATER USER S MANUAL MODEL: DSO-90, DSO-120, DSO-150, DSO-180, DSO-210, DSO-250, DSO-350 Thank you for purchasing HIPERS Far Infrared Rays heater. Please read this user s manual carefully

More information

FAR INFRARED RAYS HEATER

FAR INFRARED RAYS HEATER Wide IR Window FAR INFRARED RAYS HEATER USER S MANUAL MODEL : AH-1330 Thank you for purchasing AiRREX Far Infrared Rays heater. Please read this user s manual carefully before you operate this heater.

More information

FAR INFRARED RAYS HEATER USER'S MANUAL MODEL : AH-300/600/700/800

FAR INFRARED RAYS HEATER USER'S MANUAL MODEL : AH-300/600/700/800 FAR INFRARED RAYS HEATER USER'S MANUAL MODEL : AH-300/600/700/800 Thank you for purchasing AiRREX Far Infrared Rays heater. Please read this user's manual carefully before you operate this heater. It is

More information

FAR INFRARED RAYS HEATER USER'S MANUAL MODEL : AH-200/300/800

FAR INFRARED RAYS HEATER USER'S MANUAL MODEL : AH-200/300/800 FAR INFRARED RAYS HEATER USER'S MANUAL MODEL : AH-200/300/800 Thank you for purchasing AIRREX Far Infrared Rays heater. Please read this user's manual carefully before you operate this heater. It is recommended

More information

NON-DUCTED TYPE SMOKELESS BBQ ROASTER MODEL NJG-C

NON-DUCTED TYPE SMOKELESS BBQ ROASTER MODEL NJG-C OPERATION MANUAL NON-DUCTED TYPE SMOKELESS BBQ ROASTER MODEL NJG-C * Before operating this roaster unit, please read and understand the instructions specified in this manual for proper and safety use.

More information

Kyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings

Kyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings Contents 1. General Warnings --------------------- 1 2. Safety Warnings ----------------------- 2 3. Parts and structure --------------------- 7 4. Safety Device ------------------------- 9 5. Checkups

More information

30-pint Dehumidifier User Guide

30-pint Dehumidifier User Guide 30-pint Dehumidifier User Guide IVADH30PW Thank you for purchasing the Ivation 30 Pint Dehumidifier. This User Guide is intended to provide you with guidelines to ensure that operation of this product

More information

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS: U S E R S I N F O R M AT I O N MANUAL 2017 Lennox Industries Inc. Dallas, Texas, USA SL280UHNV SERIES 507650-01 10/2017 Improper installation, adjustment, alteration, service or maintenance can cause property

More information

SPECIFICATIONS PART NAME

SPECIFICATIONS PART NAME SPECIFICATIONS MODEL High HEAT RATING Low FUEL TANK CAPACITY BURNING TIME DIMENSIONS(W x D x H) WEIGHT VOLTAGE / FREQUENCY ELECTRICAL CONSUMPTION LC-S27 9,900 BTU / 2.9 kw 2,900 BTU / 0.8 kw 4.0 lit. 14.2~

More information

Dehumidifier. Instruction Manual. Model DH-320/A

Dehumidifier. Instruction Manual. Model DH-320/A Dehumidifier Instruction Manual Model DH-320/A CONTENTS Safety Warnings 2 Operation consideration 5 Construction & controls 6 Function selection 8 Preparation for use 10 Operation 12 Maintenance 14 Continuous

More information

INSTRUCTION MANUAL EPH-121 CONTENTS

INSTRUCTION MANUAL EPH-121 CONTENTS INSTRUCTION MANUAL EPH-121 CONTENTS SAFETY PRECAUTIONS 1 NAME OF COMPONENT PARTS 5 HOW TO ASSEMBLE THE FRAME 6 OPEN AND CLOSE THE PANELS 7 OPERATION 9 TIMER OPERATION 10 SHUTDOWN 11 ROUTINE MAINTENANCE

More information

ML180UH SERIES GAS FURNACE WARNING WARNING

ML180UH SERIES GAS FURNACE WARNING WARNING 2017 Lennox Industries Inc. Dallas, Texas, USA 506525-01 04/2017 Supersedes 10/2015 ML180UH SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

WARNING FIRE OR EXPLOSION HAZARD.

WARNING FIRE OR EXPLOSION HAZARD. 2017 Lennox Industries Inc. Dallas, Texas, USA 506698-01 04/2017 Supersedes 10/2015 SL280DFV SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property

More information

WARNING FIRE OR EXPLOSION HAZARD.

WARNING FIRE OR EXPLOSION HAZARD. 2017 Lennox Industries Inc. Dallas, Texas, USA 506897-01 04/2017 Supersedes 10/2015 EL280DF SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

1. GENERAL SAFETY RULES

1. GENERAL SAFETY RULES ID180 & ID290 Indirect-Fired Diesel/Oil Construction Heaters Sure Flame Products Lethbridge, Alberta, Canada Telephone: (403)328-5353 Fax: (403)328-9956 www.sureflame.ca July 12, 2006 Service and Maintenance

More information

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces P.O. Box 799900, Dallas, TX 75379-9900 USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in manuals,

More information

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different. RADS-51J RADS-61J Owner s Manual Room Air Conditioner with R-410A Heat Controller, Inc. 15 16 Contact an authorized service technician for repair or maintenance of this unit. Contact an authorized installer

More information

USER S INFORMATION MANUAL (2,4)SG13B

USER S INFORMATION MANUAL (2,4)SG13B USER S INFORMATION MANUAL (2,4)SG13B Series Gas Heating/Electric Cooling Package Unit Congratulations......your outdoor heating/cooling package unit is a valuable piece of equipment, designed and manufactured

More information

GDDEM10 DEHUMIDIFIER

GDDEM10 DEHUMIDIFIER GDDEM10 DEHUMIDIFIER SOCIABLE REMARK When using this dehumidifier in the European countries, the following information must be followed: DISPOSAL: Do not dispose this product as unsorted municipal waste.

More information

EL195UHE SERIES GAS FURNACE WARNING WARNING

EL195UHE SERIES GAS FURNACE WARNING WARNING 2012 Lennox Industries Inc. Dallas, Texas, USA 506737-01 12/2012 Supersedes 06/2011 EL195UHE SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property

More information

EL195UH SERIES GAS FURNACE WARNING

EL195UH SERIES GAS FURNACE WARNING 2010 Lennox Industries Inc. Dallas, Texas, USA 506597 01 11/2010 EL195UH SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could result in serious injury,

More information

WiseBath WSB Shaking Water Bath Operation Manual (Version 1.4.0)

WiseBath WSB Shaking Water Bath Operation Manual (Version 1.4.0) WiseBath WSB Shaking Water Bath Operation Manual (Version 1.4.0) written for Model WSB-18/-30/-45 Contents Page 1. Safety Instructions........ 3 2. Before Use...... 8 3. Introduction... 9 4. Package Contents...

More information

EL195DFE SERIES GAS FURNACE WARNING

EL195DFE SERIES GAS FURNACE WARNING 2011 Lennox Industries Inc. Dallas, Texas, USA 506739 01 06/2011 EL195DFE SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could result in serious injury,

More information

Corn Flame Energy Corn Stove Model 3000

Corn Flame Energy Corn Stove Model 3000 Corn Flame Energy Corn Stove Model 3000 Installation and Operation Guide Read thoroughly before starting installation Save this manual for future reference SAFETY NOTICE If this stove is not properly installed,

More information

Portable Air Conditioners

Portable Air Conditioners Owner's Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety

More information

PARAFFIN/DIESEL HEATER

PARAFFIN/DIESEL HEATER PARAFFIN/DIESEL HEATER MODEL NO: XR60 PART NO: 6931002 OPERATION & MAINTENANCE INSTRUCTIONS LS0813 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW & DOWNFLOW/HORIZONTAL CONDENSING GAS FURNACES SAFETY Recognize this symbol as an indication of Important Safety Information If not installed, operated and maintained in

More information

EL296UHV SERIES GAS FURNACE WARNING WARNING

EL296UHV SERIES GAS FURNACE WARNING WARNING 2011 Lennox Industries Inc. Dallas, Texas, USA 506769 01 08/2012 Supersedes 10/2011 EL296UHV SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property

More information

Thermal Electric Wine & Beverage Chiller Model: WC-2463W. Instruction Manual

Thermal Electric Wine & Beverage Chiller Model: WC-2463W. Instruction Manual Thermal Electric Wine & Beverage Chiller Model: WC-2463W Instruction Manual READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS BEFORE USING THIS APPLIANCE IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS

More information

Tower Ceramic Heater

Tower Ceramic Heater Instruction Manual Tower Ceramic Heater M odel : SH-1508 It is important that you read these instructions before using your new heater and we strongly recommend that you keep them in a safe place for future

More information

User Manual. 1000W Commercial Microwave. Model: 180MW1000SS 12/2014. Please read and keep these instructions. Indoor use only.

User Manual. 1000W Commercial Microwave. Model: 180MW1000SS 12/2014. Please read and keep these instructions. Indoor use only. 1000W Commercial Microwave Intertek Model: 180MW1000SS 12/2014 Please read and keep these instructions. Indoor use only. IMPORTANT SAFETY INSTRUCTIONS When using electrical equipment, basic safety precautions

More information

infrared paraffin / kerosene / diesel heater

infrared paraffin / kerosene / diesel heater instructions for infrared paraffin / kerosene / diesel heater model no: IR20.V3 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these

More information

HEA-900 EDENPURE INDOOR/OUTDOOR ALL SEASON INFRARED HEATER

HEA-900 EDENPURE INDOOR/OUTDOOR ALL SEASON INFRARED HEATER HEA-900 EDENPURE INDOOR/OUTDOOR ALL SEASON INFRARED HEATER USER MANUAL 01mf_Manuel_EdenPure_ChaufHEA-900_12025.indd 1 ALL SEASON INFRARED HEATER 01mf_Manuel_EdenPure_ChaufHEA-900_12025.indd 2 INSTRUCTION

More information

Gallery Electric Fireplaces

Gallery Electric Fireplaces Gallery Electric Fireplaces Homeowner s Installation Instructions & Operating Manual Model: GBI-34, GBI-41 Only use this heater as described in this manual. Any other use is not recommended by the manufacturer,

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW, DOWNFLOW, UPFLOW/HORIZONTAL & HORIZONTAL ONLY INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this

More information

DIESEL/PARAFFIN HEATERS

DIESEL/PARAFFIN HEATERS DIESEL/PARAFFIN HEATERS MODEL NO: XR80, XR110, XR160, XR210 PART NO: 6931004, 6931006, 6931008, 6931012 OPERATION & MAINTENANCE INSTRUCTIONS LS0814 INTRODUCTION Thank you for purchasing this CLARKE product.

More information

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED OPERATING MANUAL OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES ROOM AIR CONDITIONER WINDOW TYPE COOLING MODEL

More information

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified Thank you for purchasing our fully-automatic gas-fired tankless water heater. Please completely read this Manual

More information

Trotec PAC FT 2600 Portable air conditioner

Trotec PAC FT 2600 Portable air conditioner Trotec PAC FT 2600 Portable air conditioner The PAC FT 2600 portable room air conditioner comes with an infrared remote control and an air outlet hose with a flat nozzle.the unit s primary function is

More information

model No: ir20.v2 FUSE

model No: ir20.v2 FUSE InstructioNS for: model No: ir20.v2 INFRARED PARAFfIN / KEROSENE / diesel HEATER 70000Btu 230V Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according

More information

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference. OWNER S MANUAL DEHUMIDIFIER ESPAÑOL FRANÇAIS Read this manual carefully before operating the appliance and retain it for future reference. Model : UD701KOG1 P/NO : MFL68026017 www.lg.com TABLE OF CONTENTS

More information

en Direct oil-fired space heaters HD... Operator's manual

en Direct oil-fired space heaters HD... Operator's manual 0211670en 002 12.2007 Direct oil-fired space heaters HD... Operator's manual Table of contents 1. Foreword 5 2. Safety information 6 2.1 General recommendations... 6 2.2 Safety devices... 7 2.3 Labels...

More information

G61MPV SERIES GAS FURNACE WARNING

G61MPV SERIES GAS FURNACE WARNING 2003 Lennox Industries Inc. Dallas, Texas, USA 504,809M 03/2009 Supersedes 06/2003 G61MPV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could result

More information

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING 2015 Lennox Industries Inc. Dallas, Texas, USA 506443-01 01/2015 Supersedes 08/2012 SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL 2017 Lennox Industries Inc. Dallas, Texas, USA 506737-01 04/2017 Supersedes 03/2017 USER S INFORMATION MANUAL EL195UHE SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance

More information

KITURAMI Wood PELLET BOILER. User s Manual - KRP-20A

KITURAMI Wood PELLET BOILER. User s Manual - KRP-20A Pellet KITURAMI Wood PELLET BOILER User s Manual - KRP-20A Make sure to keep the user s manual in the vicinity of the boiler, after reading it. KITURAMI Wood Pellet Boiler The user s manual describes the

More information

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

8L DEHUMIDIFIER OPERATING INSTRUCTIONS 8L DEHUMIDIFIER OPERATING INSTRUCTIONS Attention: This Dehumidifier is rated to extract 8L per day in an environment of 80% humidity and temperature of 30 C. This is the world-wide standard for rating

More information

Maintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE

Maintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE 29-10-2013 CAUTION Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE Service the stove COMPLETELY as described in this manual. Check the chimney pipe. BLOCKED FLUE MESSAGE

More information

Bosch 80% AFUE Gas Furnace BGS80 Model

Bosch 80% AFUE Gas Furnace BGS80 Model Bosch 80% AFUE Gas Furnace BGS80 Model 4-Way Multipoise Category I Fan-Assisted Furnace User's Information Manual 3124627 2 Bosch 80% AFUE Gas Furnace User's Information Manual Data subject to change 06.2018

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW/HORIZONTAL & DOWNFLOW TWO STAGE INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this manual is not

More information

General Care and Safety Guide

General Care and Safety Guide General Care and Safety Guide Thank you for choosing a Celsius Convection Panel Heater. This Celsius appliance has been designed and manufactured to high standards of engineering and with proper use and

More information

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING See unit nameplate for manufacturer and address. 507258-04 7/2018 Supersedes 10/2017 ZG 036, 048, 060, 072, 074 (3, 4, 5 and 6 Tons) ZG 092, 102, 120, 150 (7-1/2, 8-1/2, 10 and 12 Tons) ROOFTOP UNITS ZG

More information

MODEL NO RUSSELL HOBBS APOLLO 1.8L DIGITAL FILTER COFFEE MAKER

MODEL NO RUSSELL HOBBS APOLLO 1.8L DIGITAL FILTER COFFEE MAKER INSTRUCTIONS AND WARRANTY MODEL NO. 18593 RUSSELL HOBBS APOLLO 1.8L DIGITAL FILTER COFFEE MAKER Congratulations on purchasing our Russell Hobbs Apollo 1.8L Digital Filter Coffee Maker. Each unit is manufactured

More information

IMPORTANT SAFEGUARDS Danger! Danger of burns!! Important!

IMPORTANT SAFEGUARDS Danger! Danger of burns!! Important! IMPORTANT SAFEGUARDS When using any electrical appliance, some basic safety precautions should always be observed to reduce the risk of fire, electric shock, and/or injury to persons. Read all instructions

More information

INSTALLATION &OPERATIONS MANUAL

INSTALLATION &OPERATIONS MANUAL LOW AN ULL INSTALLATION &OPERATIONS MANUAL MOBILE ROOM AIR ONDITIONER OR UTURE REERENE ONTENTS Safety Precaution... 1 Parts Description... 4 ontrol Panel... 5 Operation... 6 Accessories... 7 Installation...

More information

VAL6 EPX. Maintenance Manual

VAL6 EPX. Maintenance Manual VAL6 EPX Maintenance Manual 1 Names of components 2 Specifications Burner Control for EP6JA Wiring Diagram 0.75gal/60 H for H lot 0.85gal/60 H 3 Wiring Diagram 4 Sequence Time Chart Plug IN Switch ON Ignition

More information

1. The structure and its description

1. The structure and its description Thank you for using our KYUNG-DONG NAVIEN. To use this boiler in the proper way, be sure to read this manual fully before using it, and keep this manual with the warranty of the quality in a safe place.

More information

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER Owner s Manual Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 IMPORTANT NOTE: Read this manual carefully before installing

More information

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL Heating, Air Conditioning, Ventilation Отопление-Кондиционеры-Вентиляция MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL 1. Usage MTM 8-30 universal oil heater is designed for heating commercial rooms

More information

OWNER'S GUIDE. Gas Continuous Flow Water Heaters. Owner's Information Warranty

OWNER'S GUIDE. Gas Continuous Flow Water Heaters. Owner's Information Warranty OWNER'S GUIDE Gas Continuous Flow Water Heaters Owner's Information Warranty Models 16NG50-6/16LP50-6 16NG60-6/16LP60-6 20NG50-6/20LP50-6 20NG60-6/20LP60-6 26NG50-6/26LP50-6 26NG60-6/26LP60-6 Thermann

More information

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL Swimming Pool Heat Pump Swimming Pool Heat Pump INSTALLATION AND USER MANUAL Thank you for choosing our product and trusting our company. This manual is to provide you with necessary information for optimal

More information

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11 OWNER S MANUAL A6 Duct KPD-35 DVN11 KPD-52 DVN11 KPD-71 DVN11 KPD-90 DVN11 KPD-105 DVN11 KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11 KPD-71 DVR11 KPD-105 DVR11 KPD-105 DTR11 KPD-140

More information

WATER BATH MODEL TBS451PA OPERATION MANUAL

WATER BATH MODEL TBS451PA OPERATION MANUAL WATER BATH MODEL TBS451PA AC1120V OPERATION MANUAL No. TS45P-0601 Table of Contents Page 1. Safety instructions 1 2. Specifications 4 3. Wiring diagram & Parts 5 4. Before use 6 5. External views 9 6.

More information

AIR CONDITIONER. Please read this owner, s manual carefully before using the air conditioner, and keep this manual for the future reference.

AIR CONDITIONER. Please read this owner, s manual carefully before using the air conditioner, and keep this manual for the future reference. Owner, s Manual AIR CONDITIONER Please read this owner, s manual carefully before using the air conditioner, and keep this manual for the future reference. CONTENTS 1. Safety Precaution-------------------------------------------------------------------------------1

More information

Induction Cooktop Product Guide (IC200B)

Induction Cooktop Product Guide (IC200B) Induction Cooktop Product Guide (IC200B) http://www.avalon-bay.com Customer Care Number: 1-844-528-2566 Introduction Congratulations on your purchase of a new Avalon Bay Induction Cooktop. Before using

More information

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods

More information

Table of Contents DIGITAL DRYING OVEN. Features. Setup. Cautions. Description of the parts. Temperature Controls. Maintenance and Storage

Table of Contents DIGITAL DRYING OVEN. Features. Setup. Cautions. Description of the parts. Temperature Controls. Maintenance and Storage Table of Contents 1 Features 2 Setup 3 Cautions 4 Description of the parts 5 Temperature Controls 6 Maintenance and Storage 7 Troubleshooting 8 Warranty 9 Technical Specifications -2- Safety warnings Before

More information

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP InstructioNS for: INFRARED PARAFfIN / KEROSENE / diesel HEATER model No: ir20.v2 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these

More information

US Filtermaxx. 200,000 BTU Waste Oil Burner

US Filtermaxx. 200,000 BTU Waste Oil Burner US Filtermaxx 200,000 BTU Waste Oil Burner Assemble the Burner: Remove all the parts from the box. Locate the burner flange coupling and attach it to the front of the burner as seen in the photo below

More information

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions. Safety Precautions Unit Specifications and Features Operating Instructions Installation Instructions Care and Cleaning Troubleshooting Tips USER MANUAL Dehumidifier TDDP7011ES2 Warning notices: Before

More information

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater Contents Section Page Major Components... 2 1 About Our Manual... 2 2 Refractory Handling...

More information

Inverter Split-type Room Air Conditioner

Inverter Split-type Room Air Conditioner OWNER S MANUAL Inverter Split-type Room Air Conditioner Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.

More information

Checking the components Safety information Operating the product Other information

Checking the components Safety information Operating the product Other information 1 Feature of your product Always provide powerful elimination performance 2/4 Samsung SPi device has been applied on the left/right side of the product for quick and powerful elimination performace. Luxurious

More information

SPLIT TYPE. Instruction manual

SPLIT TYPE. Instruction manual SPLIT TYPE Instruction manual ENGLISH Instruction manual Page 1~24 To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely. 1 SAFETY PRECAUTION

More information

Dehumidifier. Instruction Manual

Dehumidifier. Instruction Manual Dehumidifier Instruction Manual Thank you very much for purchasing our dehumidifier. Before using your dehumidifier, please read this owner's manual carefully and keep it for future reference. READ AND

More information

KSD-35 DR11 KUE-35 DVN11

KSD-35 DR11 KUE-35 DVN11 FLOOR-STANDING TYPE AIR CONDITIONER Owner s Manual Floor-Standing Type KSD-35 DR11 KUE-35 DVN11 IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit.

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY...................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE..........

More information

Smokeless Roaster Operational Manual

Smokeless Roaster Operational Manual SERW_ENGLISH 101 Smokeless Roaster Operational Manual SERW J21E1E1 J21E1E2 Thank you for purchasing SHINPO Smokeless Roaster. Before operating this product, please read and understand the instructions

More information

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1 DUCTED AIR CONDITIONER Owner s Manual KD Series KD24 Kaden Owner s Manual 1 Table of Contents 1. Safety Precautions 4 2. Indoor Unit Parts and Major Functions 6 3. Care and Maintenance 8 4. Troubleshooting

More information

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL WALL MOUNT ELECTRIC FIREPLACE EF-BLT13-36 EF-BLT13-42 EF-BLT13-50 EF-BLT13-60 OWNERS MANUAL NO VENTILATION REQUIRED PRODUCES SAFE AND EFFICIENT HEAT PLEASE READ THIS ENTIRE MANUAL BEFORE USING UNIT 120-VOLT

More information

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

DF400/DF600. Construction Heaters. Installation and Maintenance Manual 342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. DF400/DF600 Construction

More information

Each heater has slightly different operational characteristics

Each heater has slightly different operational characteristics NOTE, YOU MAY WANT TO PRINT THIS GUIDE TO ASSIST YOU IN TROUBLE SHOOTING New information regarding the Ultra Low Sulfur Diesel Fuel Heater Trouble Shooting Guide Customer Name Phone Step 1. Basic Information

More information

Good Ideas For Propane Safety

Good Ideas For Propane Safety Good Ideas For Propane Safety What You Don't Know CAN Hurt You Safety...It's Up to You Propane is a safe, reliable fuel. Like many other fuels, however, it is flammable. That means it can be dangerous

More information

INSTRUCTIONS AND WARRANTY

INSTRUCTIONS AND WARRANTY INSTRUCTIONS AND WARRANTY MODEL NO. SBH46 SALTON BATHROOM HEATER Congratulations on purchasing our Salton Bathroom Heater. Each unit is manufactured to ensure safety and reliability. Before using this

More information

Electronic Ceramic Tower Heater

Electronic Ceramic Tower Heater Operating Instructions Electronic Ceramic Tower Heater Model: GCT430 General Care and Safety Guide Thank you for choosing a Goldair Ceramic Fan Heater. This Goldair Heater has been designed and manufactured

More information

Cookshack, Inc. Model FEC100 Fast Eddy Oven. Version /1/10

Cookshack, Inc. Model FEC100 Fast Eddy Oven. Version /1/10 Cookshack, Inc. Model FEC100 Fast Eddy Oven Operator s Manual Please read this entire manual installation and use of this pellet fired smoker oven. Failure to follow these instructions could result in

More information

Instantaneous Oil-Fired Water Heater Operation and Maintenance Instructions OM-122DW

Instantaneous Oil-Fired Water Heater Operation and Maintenance Instructions OM-122DW Instantaneous Oil-Fired Water Heater Operation and Maintenance Instructions MODEL OM-122DW IMPORTANT READ AND UNDERSTAND INSTRUCTIONS BEFORE INSTALLING OR USING THIS WATER HEATER. RETAIN INSTRUCTIONS FOR

More information

EC300W. Evaporative Air Cooler OWNERS MANUAL. Read and save these instructions.

EC300W. Evaporative Air Cooler OWNERS MANUAL. Read and save these instructions. EC300W Evaporative Air Cooler OWNERS MANUAL Read and save these instructions. 2 Trust should be earned and we will earn yours. Customer happiness is the focus of our business. From the factory to the warehouse,

More information

Owner s Manual Super-Slim Four-Way Cassette

Owner s Manual Super-Slim Four-Way Cassette CASSETTE- TYPE AIR CONDITIONER Owner s Manual Super-Slim Four-Way Cassette IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this

More information

Dayton Electric Infrared Fireplace User Manual

Dayton Electric Infrared Fireplace User Manual EL1239 WW13980 Dayton Electric Infrared Fireplace User Manual SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. If you are assembling this unit for someone else, give this manual to him or her to read and

More information

User Manual Watt Drop-In Induction Range. Model: DC /2017. Please read and keep these instructions. Indoor use only.

User Manual Watt Drop-In Induction Range. Model: DC /2017. Please read and keep these instructions. Indoor use only. 1800 Watt Drop-In Induction Range Model: DC1800 08/2017 Please read and keep these instructions. Indoor use only. www.avantcoequipment.com 1 Specifications Model No... DC1800 Power Rating... 500-1800W

More information

Dehumidifier. SD-46 SD-46W: with Warm Air SD-46U: with UV Light SD-46UW: with UV Light and Warm Air. Instruction

Dehumidifier. SD-46 SD-46W: with Warm Air SD-46U: with UV Light SD-46UW: with UV Light and Warm Air. Instruction Dehumidifier Instruction SD-46 SD-46W: with Warm Air SD-46U: with UV Light SD-46UW: with UV Light and Warm Air.,.,.%50% 60% 70% 80% [] Please read and retain these instructions for future reference. Please

More information

USER MANUAL SLO / SFLO115 SERIES OIL FIRED WARM AIR FURNACES

USER MANUAL SLO / SFLO115 SERIES OIL FIRED WARM AIR FURNACES USER MANUAL SLO / SFLO115 SERIES OIL FIRED WARM AIR FURNACES Save These Instructions For Reference ALL SUMMERAIRE SLO115 / SFLO115 MODELS ARE AIR CONDITIONING READY! NOTICE TO HOMEOWNER THIS FURNACE SHALL

More information

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. ENGLISH FRANÇAIS ESPAÑOL OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : Ceiling Cassette - 2Way http://www.lghvac.com

More information

Thermo 230 / 231 / 300 / 301 / Troubleshooting

Thermo 230 / 231 / 300 / 301 / Troubleshooting Thermo 230 / 231 / 300 / 301 / 350 5 Troubleshooting 5 Troubleshooting 5.1 General This section describes troubleshooting procedures for the heaters Thermo 230, 231, 300, 301 and 350. CAUTION Troubleshooting

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT MODEL RAS-260GA/RAC-260GA RAS-350GA/RAC-350GA OUTDOOR UNIT INDOOR UNIT RAC-260GA RAS-260GA RAS-350GA RAC-350GA Instruction manual Page 1~24 To obtain

More information

Portable Air Conditioners

Portable Air Conditioners Owner's Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety

More information

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL INSTALLATION AND USER MANUAL Thank you for choosing our product and trusting our company. This manual is to provide you with necessary information for optimal use and maintenance, please read carefully

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE...........

More information

General Care and Safety Guide

General Care and Safety Guide General Care and Safety Guide Thank you for choosing a Goldair Select Dehumidifier. This Goldair Select appliance has been designed and manufactured to high standards of engineering and with proper use

More information