en Direct oil-fired space heaters HD... Operator's manual
|
|
- Darcy Young
- 5 years ago
- Views:
Transcription
1 en Direct oil-fired space heaters HD... Operator's manual
2
3 Table of contents 1. Foreword 5 2. Safety information General recommendations Safety devices Labels Structure of the machine 8 4. Operation Starting up Switching on the machine Switching off the machine Transport Maintenance Malfunctions, causes, and remedies Electric wiring diagram Technical data 17 EC Declaration of Conformity 19 3
4 Table of contents 4
5 Foreword 1. Foreword This operator's manual contains information and procedures for the safe operation and maintenance of your Wacker machine. In the interest of your own safety and to prevent accidents, you should carefully read through the safety information, familiarize yourself with it and observe it at all times. This operator's manual is not a manual for extensive maintenance and repair work. Such work should be carried out by Wacker Service or authorized specialists. The safety of the operator was one of the most important aspects taken into consideration when this machine was designed. Nevertheless, improper use or incorrect maintenance can pose a risk. Please operate and maintain your Wacker machine in accordance with the instructions in this operator's manual. Your reward will be troublefree operation and a high degree of availability. Defective components should be replaced immediately! Please contact your Wacker representative if you have any questions concerning operation or maintenance. All rights reserved, especially reproduction and distribution rights. Copyright 2007 Wacker Construction Equipment AG No part of this publication may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without the expressed written permission of Wacker. Any type of reproduction, distribution or storage on data media of any type and form not authorized by Wacker represents an infringement of copyright and will be prosecuted. We expressly reserve the right to make technical modifications even without special notice which aim at further improving our machines or their safety standards. 5
6 Safety information HD Safety information 2.1 General recommendations The direct oil-fired space heaters of the HD series operate with burners which run on fuel oil. The direct oil-fired space heaters in the HD series radiate hot air as well as flue gas in the room to be heated, whereas the machines in the HI series have a flue outlet, which diverts the smoke out. The conditions of use for the machine must correspond to the regulations and laws in effect. Observe the following points: * Strictly follow the instructions in this manual. * Do not place the machine in rooms where there is a risk of explosion or in rooms where fire is not permitted to be used. * Do not store highly flammable materials in the vicinity of the machine. * All fire prevention measures must be met. * Ensure there is sufficient ventilation in the room where the machine is located. Make particularly sure there is an adequate supply of fresh air in the room, as the machine radiates warm air as well as flue gas straight into the room to be heated. * The suction and discharge pipes must be kept free of obstacles and blockages. Make sure that any cloths or covers are not put on the machine and it is not placed directly near a wall or large bulky objects. * Top up the tank with kerosene at very low room temperatures. * Check the machine before you start it and monitor it during operation. Keep children and pets away from the direct oil-fired space heater. * Always check the fan is working properly before starting up. Then connect the mains plug into the socket. * Always remove the mains plug from the socket after operation. wagsi en.fm 6
7 HD Safety devices Safety information 2.3 Labels The direct oil-fired space heater is fitted with an electronic flame monitor. If there is a malfunction, the flame monitor shuts the machine down and the control lamp (15) lights up. Identify and correct the cause of the malfunction before restarting the machine. To start up the machine again, set the main switch (14) to sition "0" and follow the instructions in section "Starting up" on page 9. Your machine has adhesive labels containing the most important instructions and safety information. * Make sure that all the labels are kept legible. * Replace any missing or illegible labels. Item Description 1 CAUTION Read the operator s manual carefully. Privide a sufficient flow of fresh air to closed rooms. Operate the unit at least 2 m away from combusstible materials. Neffer pull out the mains plug during operation or during the after-cooling phase. Only use heating oil or diesel fuel (not bio fuels). Turn off the unit before you fill the tank. wagsi en.fm 7
8 Structure of the machine HD Structure of the machine 1 Combustion chamber 7 Engine 13 Fuel tank 2 Burner 8 Fan 14 Main switch 3 Jet 9 Fuel filter 15 Control lamp 4 10 Fuel circulation 16 Connector for room thermostat cable 5 Solenoid valve 11 Support leg and handle 6 Oil pump 12 Wheel wagtx en.fm 8
9 HD Operation Operation 4.1 Starting up Before starting up the machine, check whether the power supply criteria correspond to the details on its label. Then you can connect the machine to the main power supply. Caution * The electric power supply cable for the machine must be earthed and have a fault current protective switch. * Plug the electric power supply cable of the machine into a socket which has a circuit breaker. Then the machine can only be operated automatically if it is connected up to a monitoring device, such as a thermostat or a timer. If so, disconnect the cable which connects terminals F3 and F4 to the electric jig. Plug a cable into the connector (16) and connect the cable to the monitoring device. 4.2 Switching on the machine To turn on the machine, proceed as follows: * Once a monitoring device is connected: Set the monitoring device to allow operation (for example, set thermostat to maximum temperature). * Set the main switch (14) to the "I" position: The fan starts up and after a few seconds the combustion procedure begins. For the initial start up or after the fuel oil has been completely drained from the system, the flow of fuel oil into the jet can be very low. The flame monitor switches the machine off. In this case, wait approximately one minute and then set the main switch (14) to position "0" and restart the machine. wagtx en.fm 9
10 Operation HD.... If the machine fails to start, proceed as follows: * Check there is adequate fuel oil in the tank. * Set the main switch (14) to the "0" position. * Switch on the machine again. Set the main switch (14) to the "I" position. * If the machine still does not work, see section "Malfunctions, causes, and remedies" on page 13. Identify the cause of the malfuction. Caution If the supply voltage is under 190 V, the machine switches off automatically and the control lamp flashes. The machine starts again automatically once the voltage is back up to 205 V. 4.3 Switching off the machine To switch off the machine, set the main switch (14) to position "0" or set the monitoring device at a temperature lower than room temperature. The flame goes out, the fan continues to run until the combustion chamber has fully cooled down. wagtx en.fm 10
11 HD Transport Transport Caution Before moving the device, carry out the following steps: * Switch off the machine. Follow the instructions in section "Switching off the machine" on page 10. * Disconnect the electric power supply. Pull the mains plug from the socket. * Wait until the machine has cooled down. Before lifting or moving the machine, check the tank seal is firmly closed. The machine can be pulled or pushed on the wheels for transporting. wagtx en.fm 11
12 Maintenance HD Maintenance To ensure the machine can operate properly, the combustion chamber, the burner and the fan must be cleaned regularly. Caution Before you start maintenance work, carry out the following steps: * Switch off the machine. Follow the instructions in section "Switching off the machine" on page 10. * Disconnect the electric power supply. Pull the mains plug from the socket. * Wait until the machine has cooled down. Carry out the following manitenance procedures regularly: * Clean the filter and replace if it is very dirty. * Remove the cylindrical external cladding and clean inside the machine and the cooling fins. * Check the condition of the cables and the high voltage connections on the electrodes. * Dismantle the burner and clean the individual components. Clean the electrodes and set the distance as illustrated in figure 1. Figure 1 wagtx en.fm 12
13 HD Malfunctions, causes, and remedies Malfunctions, causes, and remedies Malfunction Cause Remedy Check the criteria of the electrical system (230 V 1~ 50 Hz) No electric power Check the function and position of the main switch Fan does not start and flame does not ignite Monitoring device (thermostat, timer) incorrectly set Monitoring device is defective Motor coil has burned through or has a short Motor bearing has seized Engine condenser has burned through Check the fuses are still intact Check if the device is properly set (for example, the temperature selected on the thermostat must be higher that the room temperature) Replace the monitoring device Replace the engine Replace the engine Replace condenser wagtx en.fm 13
14 Malfunctions, causes, and remedies HD... Malfunction Cause Remedy Check the ignition cable for electrodes and transformer Ignition does not work Check the position of electrodes and their distances according to figure 1 Fan does not start and flame does not ignite or goes out again Flame monitor is defective Photo cell does not work Burner has no diesel oil or an insufficient amount Electric valve does not work Check the electrodes are clean Replace the ignition transformer Replace flame monitor Clean or replace photo cell Check the coupling between the pump and the engine Check for air bubbles in diesel oil circuit; check for leaks in pipes Clean or replace jet Check electrical connection Clean the electric valve and replace, if necessary wagtx en.fm 14
15 HD... Malfunctions, causes, and remedies Malfunction Cause Remedy Insufficient air supply for combustion Remove any objects or blockages obstructing the suction and discharge pipes Check the setting of the air adjustment ring Clean the burner disc Fan works and flame ignites but smoke is emitted Machine switches itself off and control lamp flashes Air supply is too much for combustion Diesel oil is contaminated or has water in it Air has entered the diesel oil circuit Insufficient diesel oil at burner Too much diesel oil at burner Voltage is under 190 V Check the setting of the air adjustment ring Replace the old diesel with clean diesel oil Clean or replace diesel oil filter Check pipes for leaks Check pump pressure Clean or replace jet Check pump pressure Replace jet Check the electrical system (230 V 1~ 50 Hz) Machine does not switch off Electric valve seal is faulty Replace electric valve block Fan does not switch off Fan thermostat defective Replace fan thermostat If you have carried out all the checks and corrective measures described above and the cause of the malfunction has still not been identified, please contact your nearest authorized customer service center. wagtx en.fm 15
16 Electric wiring diagram HD Electric wiring diagram FU Fuse 4 A AP Control unit MV Fan motor IT Transformer A.T. EV Solenoid valve FA Fan thermostat SB Control lamp "OFF" IN Main switch TA Bushing for room thermostat FO Photo resistor wagtx en.fm 16
17 HD Technical data Technical data Unit HD 30 HD 45 Item number Max. thermal output [kcal/h] 25,800 38,700 Air flow performance [m³/h] 450 1,400 Net thermal output [kw] Fuel consumption [kg/h] [l/h] Voltage [V] 230 1~ 230 1~ Frequency [Hz] Electrical power [W] Jet [USgal/h] S S Pump pressure [bar] Setting the burner air shutter [mm] a = 8 (Figure 2) a = 20 (Figure 2) Tank capacity [l] Noise level at 1 m [dba] Dimensions, L x W x H [mm] 1070 x 480 x x 480 x 734 Weight [kg] Figure 2 wagtd en.fm 17
18 Technical data HD... wagtd en.fm 18
19 EC Declaration of Conformity Wacker Construction Equipment AG, Preußenstraße 41, München certifies that the construction machine: Type: Direct oil-fired space heater Type HD 30 HD 45 Machine type number Installed thermal output [kw] Noise level at 1 m distance [dba] fulfills the requirements of the directive 89/392/EC with amendments 91/368, 93/44, 93/68, and 98/37. The machine was constructed in accordance with the following directives: 89/336/EC 92/31/EC 73/23/EC Please keep this document in a safe place Dr. Stenzel Head of Research and Development
20 Wacker Construction Equipment AG - Preußenstraße München - Tel.: +49-(0) Fax: +49-(0) Wacker Corporation - P.O. Box Menomonee Falls, WI Tel.: +1 (1) Fax: +1 (1) Tel.: Wacker Machinery Ltd.- Skyline Tower, Suite 2303, 23/F, 39 Wang Kwong Road, Kowloon Bay, Hong Kong -Tel.: Fax:
21
22
en Inverter FU 4/5. Operator s Manual
0201424en 006 12.2012 Inverter FU 4/5 Operator s Manual Manufacturer Wacker Neuson Produktion GmbH & Co. KG Preußenstraße 41 80809 München www.wackerneuson.com Tel.: +49-(0)89-354 02-0 Fax: +49-(0)89-354
More informationen Indirect Lighting System LB 1 OPERATOR S MANUAL
0163721en 003 0708 Indirect Lighting System LB 1 OPERATOR S MANUAL 0 1 6 3 7 2 1 E N LB 1 Table of Contents Foreword 4 1 Safety Information 5 1.1 Callouts Found in this Manual... 5 1.2 Safety Guidelines
More informationIDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80
IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20-30-50-60-80-TC-001-EN Table of contents Information on the use of this manual... 1 Scope of delivery... 1 General safety...
More information1. GENERAL SAFETY RULES
ID180 & ID290 Indirect-Fired Diesel/Oil Construction Heaters Sure Flame Products Lethbridge, Alberta, Canada Telephone: (403)328-5353 Fax: (403)328-9956 www.sureflame.ca July 12, 2006 Service and Maintenance
More informationDH-Direct Fired Poultry Farm Diesel Heater
DH-Direct Fired Poultry Farm Diesel Heater Comparison of Diesel Heater to Gas Heater Diesel LPG Gas LPG Gas KW 43 70 120 Fuel consumption/hr 3 5.1 8.8 Heat output 37000 60000 100000 Cost of fuel/lit or
More informationFLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING
FLAME115 INFRARED HEATER SERVICE MANUAL INDEX 1. CONTROLS AND COMPONENTS 2. FLAME CONTROL CYCLES 3. MAINTENANCE SCHEDULE 4. TROUBLESHOOTING GUIDE 5. REPAIR PROCEDURES 1. FAN MOTOR ASSEMBLY 2. FUEL FILTER
More informationen Electric hammer EH 9 BL, BLM, BLS. Operator's manual
0212728en 002 05.2008 Electric hammer EH 9 BL, BLM, BLS Operator's manual Inhalt Contents 1 Foreword... 5 2 Introduction... 6 2.1 Means of representation for this operator's manual... 6 2.2 WACKER representative...
More informationJUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS
JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods
More informationForced draught gas burner
Installation, use and maintenance instructions Forced draught gas burner Code Model Type 3751982 GAS 3 519T80 291 (3) - 02/2010 DECLARATION Declaration of conformity in accordance with ISO / IEC 17050-1
More informationInstallation & Maintenance Manual
Installation & Maintenance Manual MOL 200 S1L (B30A) Oil Burner 11/12 Tel: +44 (0) 1905 794331 Fax: +44 (0) 1905 794017 Email: info@nu-way.co.uk Web: www.nu-way.co.uk DESCRIPTION COMPONENTS 1. Shrouded
More informationOPERATING & MAINTENANCE MANUAL DC10 DC15 DC25 DC40 DC45
OPERATING & MAINTENANCE MANUAL INDUSTRIAL DIRECT FIRED DIESEL/KEROSENE HEATERS DC10 DC15 DC25 DC40 DC45 Made By: NOT FOR DOMESTIC USE SPACE HEATING ONLY Spitwater Australia Pty Ltd 953 Metry St., North
More informationen EXTERNAL VIBRATORS ARFU. Operator s Manual
0109968en 006 09.2010 EXTERNAL VIBRATORS ARFU Operator s Manual Manufacturer Wacker Neuson SE Preußenstraße 41 80809 München www.wackerneuson.com Tel.: +49-(0)89-354 02-0 Fax: +49-(0)89-354 02-390 Translation
More informationINSTRUCTION MANUAL FOR OIL BURNER MODELS
INSTRUCTION MANUAL FOR OIL BURNER MODELS X500 Bio B10 E90-803-001-001-00 Rev 7-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...
More informationINSTRUCTION MANUAL FOR OIL BURNER MODELS
INSTRUCTION MANUAL FOR OIL BURNER MODELS X400 Bio B10 E90-803-001-001-03 Rev 13-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...
More informationRepair Manual Indirect-Fired Air Heater Cub 200 Cub 300
Repair Manual Indirect-Fired Air Heater Cub 200 Cub 300 0179422en 001 1009 0 1 7 9 4 2 2 E N Copyright notice Copyright 2009 by Wacker Neuson Corporation. All rights, including copying and distribution
More informationLight oil burners. One stage operation
Installation, use and maintenance instructions Light oil burners One stage operation CODE MODEL TYPE 3505 RDB CF 38 50 T3 350050 RDBR CF 6 50 TR 35050 RDBR CF 33 50 TR 35050 RDBR CF 38 50 T3R 350650 RDBR
More informationOil TRIANCO. EuroStar Range BURNER DETAILS TRIANCO - OIL BURNER. To be retained by householder
TRIANCO Oil TRIANCO - OIL BURNER BURNER DETAILS EuroStar Range To be retained by householder TECHNICAL DATA NOZZLE OUTPUT MODEL Output Burner Nozzle Pump Model pressure CO 2 (%) EUROSTAR UTILITY 50/65
More informationen EXTERNAL VIBRATORS AR 54. Operator s Manual
0200070en 007 04.2010 EXTERNAL VIBRATORS AR 54 Operator s Manual Manufacturer Wacker Neuson SE Preußenstraße 41 80809 München www.wackerneuson.com Tel.: +49-(0)89-354 02-0 Fax: +49-(0)89-354 02-390 Translation
More informationen Cutting machine RCE. Operator's manual
0215051en 003 12.2009 Cutting machine RCE Operator's manual Manufacturer Wacker Neuson SE Preußenstraße 41 80809 München www.wackerneuson.com Tel.: +49-(0)89-354 02-0 Fax: +49-(0)89-354 02-390 Translation
More informationen Electric-breaker EH 23/... Operator s Manual
www.wackergroup.com 0203373en 002 10.2006 Electric-breaker EH 23/... Operator s Manual 1. Foreword Foreword For your own safety and protection from bodily injuries, carefully read, understand and follow
More informationOPERATING & MAINTENANCE MANUAL INDUSTRIAL DIRECT FIRED DIESEL/KEROSENE HEATERS IC 25
OPERATING & MAINTENANCE MANUAL INDUSTRIAL DIRECT FIRED DIESEL/KEROSENE HEATERS IC 25 NOT FOR DOMESTIC USE SPACE HEATING ONLY Made By: Spitwater Australia Pty Ltd 953 Metry St North Albury, NSW, Australia
More informationINSTALLATION AND OPERATION MANUAL
INSTALLATION AND OPERATION MANUAL PRESSURISED STEEL BOILERS AR 30 AR 1000 RADIALAND - BOILER's INSTALLATION MANUAL version 1.0 / 15-02-2008 The company E. is outstanding in the field of central heating
More informationThermo 230 / 231 / 300 / 301 / Troubleshooting
Thermo 230 / 231 / 300 / 301 / 350 5 Troubleshooting 5 Troubleshooting 5.1 General This section describes troubleshooting procedures for the heaters Thermo 230, 231, 300, 301 and 350. CAUTION Troubleshooting
More informationINSTRUCTION MANUAL FOR OIL BURNER MODELS
INSTRUCTION MANUAL FOR OIL BURNER MODELS X500-2 Low voltage 12v dc Brushed motor E90-803-001-005-01 Rev 4-1 - Contents Technical specifications Technical data...3 Working field...3 Dimensions...4 Head
More information15 20 kw kw kw
Burner Set-up Details 15 20 kw 20 26 kw 29 36 kw Riello RDB2 Please read these instructions carefully before commissioning and using this appliance. To be retained by the householder HEALTH AND SAFETY
More informationCODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80
Installation, use and maintenance instructions Heavy oil burner CODE MODEL TYPE 3434985 PRESS 60 N 616 T80 3434986 PRESS 60 N 616 T80 291 (2) - 01/2009 Thermal power - Output Operation Fuel Electrical
More informationIDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D
IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20D-30D-50D-60D-100D-TC-001-EN Table of contents Notes regarding the operating manual... 1 Safety... 2 Information
More informationInfrared Diesel Heater
Infrared Diesel Heater Model No: IRD40 PART NO: 6920415 OPERATING & MAINTENANCE INSTRUCTIONS GC0812 INTRODUCTION Thank you for purchasing this CLARKE Diesel Infrared Heater. Before attempting to use the
More informationLight oil / kerosene burner
Installation, use and maintenance instructions Light oil / kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 290238 (5) - 05/20 TECHNICAL DATA Thermal power output 28 60 kw 2.3 5 kg/h
More informationVAL6 EPX. Maintenance Manual
VAL6 EPX Maintenance Manual 1 Names of components 2 Specifications Burner Control for EP6JA Wiring Diagram 0.75gal/60 H for H lot 0.85gal/60 H 3 Wiring Diagram 4 Sequence Time Chart Plug IN Switch ON Ignition
More informationProviding sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A
178 038 51-2 2016-07-08 Providing sustainable energy solutions worldwide Installation- and maintenance instruction B 30 A DESCRIPTION Components 1. Shrouded disc 2. Nozzle 3. Ignition electrodes 4. Nozzle
More informationCleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2
Cleaning unit for coolant :_decftez`_>r_fr] Book No.: 1271526-02 V2 Alfa Laval Separation AB Separator Manuals, dept. SKEL S-147 80 Tumba, Sweden Telephone: +46 8 53 06 50 00 Telefax: +46 8 53 03 10 40
More informationForced draught gas burner
Installation, use and maintenance instructions GB Forced draught gas burner One stage operation CODE MODEL TYPE 3751782 GAS 5 517T80 291 (4) - 07/2015 Declaration of conformity in accordance with ISO /
More informationOperator's manual. Rebar tier DF 16
Operator's manual Rebar tier DF 16 EN 5200006665 06 0811 5 2 0 0 0 0 6 6 6 5 08.2011 0214885en / 006 Manufacturer Wacker Neuson Produktion GmbH & Co. KG Preußenstraße 41 80809 München www.wackerneuson.com
More informationTrumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!
Trumatic E 7 7 2 9 9 4 Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7 To be kept in the vehicle! Trumatic E 2400 (Australia) Table of contents Installation example...
More informationLight oil - kerosene burner
Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 374374 G3B 437T 90 (4) - 05/0 TECHNICAL FEATURES TYPE 437T Thermal power output 9 35 kw.6
More informationInstallation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)
Installation & Operating Manual ZM-130 16 32kW Universal Oil Heater OVERVIEW Dfdfdfdsfd Dfdfffdfdf Dfdfdf 4 1. Overheat thermostat 2. Combustion chamber lid 3. Oil feed line 4. Activation thermostat 5.
More informationPS PS PSA 2 500
0154621en 003 1008 Pump PS 2 500 PS 2 750 PSA 2 500 OPERATOR S MANUAL 0 1 5 4 6 2 1 E N Foreword Foreword This manual provides information and procedures to safely operate and maintain this Wacker Neuson
More informationINSTALLATION AND MANINTENANCE INSTRUCTIONS
INSTALLATION AND MANINTENANCE INSTRUCTIONS Appr. Nr. A 9503 T - 0085 AQ 0765 PEGASUS F2 T HIGH EFFICIENCY GAS-FIRED CAST-IRON BOILERS Models 51-68 - 85-102 2 Contents 1. General technical data 2. Dimensional
More informationPropane Heater REMKO PGM 30 REMKO PGM 60
Propane Heater REMKO PGM 30 REMKO PGM 60 Operation Technology Spare Parts Edition GB L07 REMKO strong as a bear. Operating instructions Make sure to read these instructions carefully before starting/using
More informationHOT WASHER MODEL NO: KING150
WARNING: Do not use the hot washer without reading this manual HOT WASHER MODEL NO: KING150 PART NO: 7320175 OPERATION & MAINTENANCE INSTRUCTIONS LS1215 INTRODUCTION Thank you for purchasing this CLARKE
More informationBosch 80% AFUE Gas Furnace BGS80 Model
Bosch 80% AFUE Gas Furnace BGS80 Model 4-Way Multipoise Category I Fan-Assisted Furnace User's Information Manual 3124627 2 Bosch 80% AFUE Gas Furnace User's Information Manual Data subject to change 06.2018
More informationNON-DUCTED TYPE SMOKELESS BBQ ROASTER MODEL NJG-C
OPERATION MANUAL NON-DUCTED TYPE SMOKELESS BBQ ROASTER MODEL NJG-C * Before operating this roaster unit, please read and understand the instructions specified in this manual for proper and safety use.
More informationOIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE
58CLA OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. WELCOME TO A NEW GENERATION
More informationFHA 1100 A1 Domestic Water Pump
FHA 1100 A1 Domestic Water Pump Translation of original operation manual 6 Before reading, unfold the page containing the illustrations and familiarise yourself with all functions of the device. / Translation
More informationen Hydronic Surface Heater E 1100 REPAIR MANUAL
0176742en 002 0209 Hydronic Surface Heater REPAIR MANUAL 0 1 7 6 7 4 2 E N Foreword Foreword Machines covered by this manual Machine Item Number 0620172 0620244 Machine documentation Keep a copy of the
More informationDF400/DF600. Construction Heaters. Installation and Maintenance Manual
342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. DF400/DF600 Construction
More informationWhole Room Dryer WRD, WRD/110
Whole Room Dryer WRD, WRD/110 User Instructions Whole Room Dryers CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03-8117-0000 Iss.1 12/06 Fig 1 Fig 2 Fig 3 Fig 4 CONTENTS Page 1 Product information...................4
More informationIST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE
IST 03 C 202-01 ELBA DUAL INSTALLATION, USE AND MAINTENANCE GB Thank you for choosing our boilers. Please read these installation and maintenance instructions with care. Please note that the boiler must
More informationOperating instructions
Operating instructions Capriz 2 24c 28c GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information... 4 2 Notes on the documentation...
More informationFar-infrared Oil Heater Owner's manual
16 Appearance and/or specifications of product can be changed for better quality and preference without prior notice ar-infrared Oil Heater Owner's manual 1 URRENT TEMP EMPTY UEL TARGET TEMP ALARM Heating
More informationOperating instructions
The energy you need Operating instructions Betacom 3 24c -A (H-GB) 30c -A (H-GB) GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information...
More informationWHU WATER HEATING UNITS. GENERAL MANUAL MODEL KEY. June 2007 WHU WATER HEATING UNITS
WHU WATER HEATING UNITS GENERAL MANUAL MODEL KEY WHU Water Heating Unit Maximum heating power, kw Max. water inflow pressure, bar Voltage options GENERAL INFORMATION WHU water heater, producing hot water
More informationMODULAR AUTOMATIC GRANULAR ICE FLAKER
MODULAR AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24479 rev. 03 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having
More informationSPECIFICATIONS PART NAME
SPECIFICATIONS MODEL High HEAT RATING Low FUEL TANK CAPACITY BURNING TIME DIMENSIONS(W x D x H) WEIGHT VOLTAGE / FREQUENCY ELECTRICAL CONSUMPTION LC-S27 9,900 BTU / 2.9 kw 2,900 BTU / 0.8 kw 4.0 lit. 14.2~
More informationModel No: Little Devil II (inc ss)
GAS HEATER Model No: Little Devil II (inc ss) PART NO: 6926020, 6926025 (SS) OPERATION & MAINTENANCE INSTRUCTIONS LS1213 INTRODUCTION Thank you for purchasing this CLARKE Gas Heater. Before attempting
More informationOperator s Manual. Hydronic Air Heater. Arctic Bear XHD-NS en /
Operator s Manual Hydronic Air Heater Arctic Bear XHD-NS 0 1 7 8 3 9 1 E N 0178391en / 001 1107 Arctic Bear XHD Foreword Foreword Machines covered by this manual This manual covers machines with the following
More informationOperator s Manual. Light Balloon LB en
Operator s Manual Light Balloon LB 1 0175081en 004 0410 0 1 7 5 0 8 1 E N Copyright notice Copyright 2010 by Wacker Neuson Corporation. All rights, including copying and distribution rights, are reserved.
More informationOperating instructions
Operating instructions Gas-fired condensing boiler Logano plus GB312 For the user Please read carefully before use 7 747 009 296-01/2007 EN Contents 1 For your safety..............................................
More informationOpen Vented Condensing Boilers
Dimplex 18 OV Dimplex 32 OV Open Vented Condensing Boilers User s Operating Instructions These instructions should be left with the user Dimplex Boilers 2008 CONTENTS SECTION DESCRIPTION PAGE 1.0 Using
More informationOperating instructions
Operating instructions For the operator Operating instructions HOME SYSTEM GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18 0 Fax +49 21 91 18 28 10 info@vaillant.de
More informationKyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings
Contents 1. General Warnings --------------------- 1 2. Safety Warnings ----------------------- 2 3. Parts and structure --------------------- 7 4. Safety Device ------------------------- 9 5. Checkups
More informationen Electric hammer EHB 11 BL, BLM, BLS. Operator's manual
0212727en 003 05.2009 Electric hammer EHB 11 BL, BLM, BLS Operator's manual Manufacturer Wacker Neuson SE Preußenstraße 41 80809 München www.wackerneuson.com Tel.: +49-(0)89-354 02-0 Fax: +49-(0)89-354
More informationServicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use
GB122 Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C For trade use Please read thoroughly before attemting to diagnose fault 7217 4900 (03/2010) GB/IE List of contents
More informationOil burners Brûleurs fioul Stookoliebranders
Installation, use and maintenance instructions Manuel d entretien Installatie-, gebruiks- en onderhoudsvoorschriften GB F NL Oil burners Brûleurs fioul Stookoliebranders One stage operation Fonctionnement
More informationServicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use
GB122 7210 1300-12/2002 GB(EN) For trade use Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C Please read thoroughly before attempting to diagnose fault List of contents
More informationGas-Gebläsebrenner Brûleur gaz à air soufflé Forced draught gas burner Gasventilatorbrander Quemador de gas de aire soplado
Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Instrucciones para la instalación, uso y mantenimiento
More informationHeating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL
Heating, Air Conditioning, Ventilation Отопление-Кондиционеры-Вентиляция MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL 1. Usage MTM 8-30 universal oil heater is designed for heating commercial rooms
More informationNOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.
c_::_':_-_:_ r'" _" "_1 WARNING: If the information in this manual is not followed exactly, a fire or explosion may Iresult causing property damage, personal injury or [loss of life. m m m Do not store
More informationOperator's manual. Rebar tier DF en / 004
Operator's manual Rebar tier DF 16 03.2009 0214885en / 004 Manufacturer Wacker Neuson SE Preußenstraße 41 80809 München www.wackerneuson.com Tel.: +49-(0)89-354 02-0 Fax: +49-(0)89-354 02-390 Translation
More informationCAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE
User instructions Model X46 Escalator and Travelator cleaner CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03-7845-0000 Iss.1 07/04 Fig 1 Fig 2 2 Contents Page 1 Product information... 4 1.1
More informationTERRACE AND PATIO HEATER
TERRACE AND PATIO HEATER USER INSTALLATION AND OPERATION GUIDE INDEX General and specifications.1,2 Security and caution.. 3 Tools and accessories required 5 Assembly instructions 5-7 Operation (Lighting
More informationINTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION
INSTALLATION AND OPERATING INSTRUCTIONS FOR THE HARDY Fuel Oil Furnace Models D-140 & D-350 HARDY MANUFACTURING COMPANY, INC. 12345 ROAD 505 PHILADELPHIA, MS 39350 PHONE: (601) 656-5866 FAX: (601) 656-4559
More informationATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL
STREBEL GENEVA CE ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL INDEX TABLE 1 TECHNICAL DATA SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION
More informationOperating instructions. Air heater Air Top Evo 40 Air Top Evo 55 for motor homes
EN Operating instructions Air heater Air Top Evo 40 Air Top Evo 55 for motor homes 1 1 About this document 1.1 Purpose of the document This operating instruction is part of the product and provides the
More informationOperating instructions
6304 0307 04/2005 US For the installer Operating instructions Sealed combustion boiler Logano GA24 SC and atmospheric boiler Logano G24X II/SP If these instructions are not followed exactly, a fire or
More informationHEATING SYSTEMS. Thermo plus 230 Thermo plus 300 Thermo plus 350. Thermo plus Rail. Workshop Manual. Rev. 04/2018 Id.No B
HEATING SYSTEMS Thermo plus 230 Thermo plus 300 Thermo plus 350 Thermo plus Rail Workshop Manual Rev. 04/208 Id.No. 256B Thermo plus 230/300/350 Content Introduction. Content and purpose 0.2 Effectivity
More informationProviding sustainable energy solutions worldwide. Installation- and maintenance instruction B 45A
178 017 55-1 2016-05-19 Providing sustainable energy solutions worldwide Installation- and maintenance instruction B 45A DESCRIPTION Components 1. Flame cone 2. Ignition electrodes 3. Nozzle assembly
More informationTERRACE AND PATIO HEATER
TERRACE AND PATIO HEATER USER INSTALLATION AND OPERATION GUIDE INDEX General and specifications.11 Security and caution.. 12, 13 Tools and accessories required 13 Assembly instructions 14,15 & 16 Verifying
More informationOPERATING & MAINTENANCE INSTRUCTIONS
CERAMIC HEATER Model: Devil 350 Part No: 6920262 OPERATING & MAINTENANCE INSTRUCTIONS GC11/11rev1 INTRODUCTION Thank you for purchasing this CLARKE Ceramic Heater. Please read this manual thoroughly and
More informationGAS FIRED CONVECTION HEATERS WITH FAN GHIBLI SERIES Models Technical information
GAS FIRED CONVECTION HEATERS WITH FAN GHIBLI SERIES Models 4-5 - 6 This manual is divided into three sections: Technical information - SECTION 1 - GENERAL INFORMATION It contains all the information relevant
More informationOperating Manual JuniorPower
To be read completely before start-up! Operating Manual JuniorPower 12/04 von Oertzen GmbH Ferdinand-Harten-Str. 10 22949 Ammersbek Tel. +49 40 604110 Fax +49 40 6041149 www.oertzen-gmbh.de info@oertzen-gmbh.de
More informationCombivac Operating Instructions Combivac
Combivac 17-36 Operating Instructions Combivac General Table of contents General...2 Table of contents...2 Information about the operating instructions...3 Liability...3 Notices in the operating instructions...3
More informationNOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.
RADS-51J RADS-61J Owner s Manual Room Air Conditioner with R-410A Heat Controller, Inc. 15 16 Contact an authorized service technician for repair or maintenance of this unit. Contact an authorized installer
More information1. The structure and its description
Thank you for using our KYUNG-DONG NAVIEN. To use this boiler in the proper way, be sure to read this manual fully before using it, and keep this manual with the warranty of the quality in a safe place.
More informationHI 110D / HI 110HD D HI 200D / HI 200HD D HI 300D / HI 300HD D
Operator s Manual Indirect-Fired Air Heaters HI 110D / HI 110HD D HI 200D / HI 200HD D HI 300D / HI 300HD D EN 5000192822 03 1211 5 0 0 0 1 9 2 8 2 2 Copyright notice Copyright 2011 by Wacker Neuson Production
More informationen Vibratory plate DPS 1850H. Basic. Operator s Manual
0109973en 004 12.2009 Vibratory plate DPS 1850H Basic Operator s Manual Manufacturer Wacker Neuson SE Preußenstraße 41 80809 München www.wackerneuson.com Tel.: +49-(0)89-354 02-0 Fax: +49-(0)89-354 02-390
More informationAUTOMATIC GRANULAR ICE FLAKER
AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24480 rev. 01 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on choosing a
More informationST 40 Oil Burner. Installation & Maintenance Manual
ST 40 Oil Burner Installation & Maintenance Manual 178 093 13 Thank you for choosing a Nu-way burner. As you would expect from a Company who has a pedigree of more than 75 years in the heating industry,
More informationAHE S -12 VDC AHE S - 24 VDC
Owner s Manual Model Numbers AHE-100-02S -12 VDC AHE-200-02S - 24 VDC OWNER S INFORMATION Owner s Name: Address: City: State: Zip Code: CUT HERE AND MAIL IN Telephone: Coach Model: Coach Date of Purchase:
More informationUser s Information Manual
48TJD005-014 48TJE004-014 48TJF004-012 Single-Package Rooftop Heating/Cooling Units User s Information Manual NOTE TO INSTALLER This manual should be left with the equipment owner. FOR YOUR SAFETY Do not
More information15KW ELECTRIC FAN HEATER
15KW ELECTRIC FAN HEATER MODEL NO: DEVIL 7015 PART NO: 6935456 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product,
More informationKEROSENE FORCED AIR HEATER
KEROSENE FORCED AIR HEATER operation manual HK125RW HK300RW 2 table of contents Safety 6 Safety Rules 7 Safety Warnings Specifications 12 Specifications 13 Wiring Diagram Pre-Operation 14 General Instructions
More informationen Cutting machine with interchangeable head RCP 20, 25. Operator's manual
0215052en 002 03.2008 Cutting machine with interchangeable head RCP 20, 25 Operator's manual Contents Contents 1 Foreword... 5 2 Introduction... 6 2.1 Means of representation for this operator's manual...
More informationOperator s manual. Internal vibrator with integrated inverter IRFU en / 12
Operator s manual Internal vibrator with integrated inverter IRFU 02.2015 5000212651en / 12 Manufacturer Wacker Neuson Produktion GmbH & Co. KG Preußenstraße 41 80809 München www.wackerneuson.com Tel.:
More informationUser instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE
User instructions VA20HD, VA55HD, VA55IND and VA75IND Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03-8112-0000 Iss.3 07/08 http://www.truvox.com/products/vacuums/valet_aqua
More information30KW ELECTRIC FAN HEATER
30KW ELECTRIC FAN HEATER MODEL NO: DEVIL 7030 PART NO: 6935458 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product,
More informationOperating instructions
Operating instructions For the operator Operating instructions ecotec plus Gas-fired wall-hung high-efficiency boiler GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Telefon
More informationTermEfekt USER S MANUAL AIR HEATER. Model PGA 14
Przedsiębiorstwo Produkcyjno-Wdrożeniowe ARAJ sp. z o.o. 55-080 Kąty Wrocławskie, ul. Mireckiego 30 POLAND USER S MANUAL AIR HEATER TermEfekt Model PGA 14 Kąty Wrocławskie, 2004 Product identification
More informationOperating instructions
Operating instructions Gas condensing boiler WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
More information