en Hydronic Surface Heater E 1100 REPAIR MANUAL

Size: px
Start display at page:

Download "en Hydronic Surface Heater E 1100 REPAIR MANUAL"

Transcription

1 en Hydronic Surface Heater REPAIR MANUAL E N

2

3 Foreword Foreword Machines covered by this manual Machine Item Number Machine documentation Keep a copy of the Operator s Manual with the machine at all times. Use the separate Parts Book supplied with the machine to order replacement parts. If you are missing any of these documents, please contact Wacker Neuson Corporation to order a replacement or visit When ordering parts or requesting service information, be prepared to provide the machine model number, item number, revision number, and serial number. Expectations for information in this manual This manual provides information and procedures to safely repair the above Wacker Neuson model(s). For your own safety and to reduce the risk of injury, carefully read, understand, and observe all instructions described in this manual. Wacker Neuson Corporation expressly reserves the right to make technical modifications, even without notice, which improve the performance or safety standards of its machines. The information contained in this manual is based on machines manufactured up until the time of publication. Wacker Neuson Corporation reserves the right to change any portion of this information without notice. Copyright notice All rights, especially copying and distribution rights, are reserved. Copyright 2008 by Wacker Neuson Corporation. This publication may be reproduced through photocopying by the original purchaser of the machine. Any other type of reproduction is prohibited without express written permission from Wacker Neuson Corporation. Any type of reproduction or distribution not authorized by Wacker Neuson Corporation represents an infringement of valid copyrights, and violators will be prosecuted. Trademarks All trademarks referenced in this manual are the property of their respective owners. ghi_tx000976gb.fm 3

4 Foreword ghi_tx000976gb.fm 4

5 Table of Contents 1 Safety Information Signal Words Found in this Manual Safety Guidelines for Operating the Machine Safety Guidelines for Lifting the Machine Safety Guidelines While Using Combustion Burners Safety Guidelines while Using Internal Combustion Engines Safety Guidelines for Maintaining the Machine Controls and Components External Components Internal Components Control Panel Detail Troubleshooting Basics Where to Start Power Components Checking the Power Supply Checking the Circuit Breaker Checking a GFCI Heating System Burner Controller Periods and Modes Heating System Troubleshooting Strategy Checking the Burner Switch Checking the Low-Level Shut-Down Device Checking Relay K Diagnosing Heating System Problems Checking the Temperature Controller Checking the Burner Controller (SN 1538 and higher) Checking the Burner Controller (SN 1537 and lower) ghi_br en_002toc.fm 5

6 Table of Contents 5.10 Checking the Snap Disc (Thermal Limit) Checking the Burner Fan Motor Checking the Cad Cell Checking the Oil Valve Checking the Fuel Filter Checking the Ignition Transformer Checking the Thermocouple Checking Relay K1 (SN 1538 and higher) Checking Relay K1 (SN 1537 and lower) Circulation System Diagnosing the Circulation System Troubleshooting the Circulation System Checking the Pump Switch Checking the Low-Level Shut-Down Device Checking Relay K Checking the Pump Motor Rewind System Troubleshooting the Rewind System Checking Fuse 1 and Fuse Checking the Rewind Switch (SN 1538 and higher) Checking the Rewind Switch (SN 1537 and lower) Checking the Rewind Motor Checking the Rewind Clutch (Solenoid) Checking the Rewind Transformer (SN 1538 and higher) Checking the Rewind Transformer (SN 1537 and lower) Checking the Rectifier (SN 1538 and higher) Checking the Rectifier (SN 1537 and lower) Checking the Foot Switch Checking the Rewind System Mechanical Components...88 ghi_br en_002toc.fm 6

7 Table of Contents 8 Miscellaneous Components Checking the Duplex Receptacle Checking an Indicator Light Checking the Fuel Prewarmer Burner Setup Determining the Burner Head Type Setting/Checking the Electrodes Checking/Replacing the Nozzle Setting the Z Distance ( L head) Setting the Z Distance ( F head) Adjusting the Air Settings Setting the Fuel Pressure Disassembly and Assembly Tools Required for Disassembly/Assembly Procedures Information Regarding Replacement Parts Information Regarding Reference Numbers Removing the Burner Installing the Burner Replacing the Fuel Pump Replacing the Burner Fan Motor Replacing an HTF Pump Replacing the HTF Pump Motor Changing a Turbulator/Cleaning a Turbulator Tube Repairing a Hose Changing a HTF Filter Changing the Low-Level Probe Replacing the Thermocouple Schematics Composite Schematic (SN 1538 and higher) Composite Components Burner System Circuit ghi_br en_002toc.fm 7

8 Table of Contents 11.4 Circulation System Circuit Rewind System Circuit Composite Schematic (SN 1537 and lower) Technical Data Dimensions Appendix Omron Temperature Controller Programming Fuji Temperature Controller Hysteresis (differential) Adjusting Fuji Temperature Controller Low Temperature Limit Adjusting Fuji Temperature Controller High Temperature Limit Adjusting Threadlockers and Sealants Torque Values ghi_br en_002toc.fm 8

9 1 Safety Information 1.1 Signal Words Found in this Manual Safety Information This is the safety alert symbol. It is used to alert you to potential personal hazards. Obey all safety messages that follow this symbol. DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. Obey all safety messages that follow this symbol to avoid injury or death. WARNING WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. Obey all safety messages that follow this symbol to avoid possible injury or death. CAUTION CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Obey all safety messages that follow this symbol to avoid possible minor or moderate injury. NOTICE: Used without the safety alert symbol, NOTICE indicates a situation which, if not avoided, could result in property damage. Note: Contains additional information important to a procedure. ghi_si000281gb.fm 9

10 Safety Information 1.2 Safety Guidelines for Operating the Machine Operator training Before operating the machine: Read and understand the operating instructions contained in all manuals delivered with the machine. Familiarize yourself with the location and proper use of all controls and safety devices. Contact Wacker Neuson Corporation for additional training if necessary. When operating this machine: Do not allow improperly trained people to operate the machine. People operating the machine must be familiar with the potential risks and hazards associated with it. Machine condition Only operate the machine when: All safety devices and guards are in place and in working order. All controls operate correctly. The machine is set up correctly according to the instructions in the Operator s Manual. The machine is clean. The machine s labels are legible. When operating the machine: Do not modify or defeat the safety devices. Do not use worn electrical cords. Do not use faulty fuel supplies. Guidelines for operator When operating the machine: Remain aware of the machine s moving parts. Keep hands, feet, and loose clothing away from the machine s moving parts. Wear protective clothing appropriate to the job site when operating the machine. Wear safety glasses. Wear gloves when handling the heat transfer hoses. When operating the machine: Never operate a machine in need of repair. Do not smoke near the machine. Do not disconnect the heat transfer hoses when the pumps are operating or a burner is firing. Work space When operating the machine: Position the machine on a firm, noncombustible, level surface, and chock wheels. Position the machine on the job site so that neither it or the operator are standing in water. ghi_si000281gb.fm 10

11 Safety Information Keep the area immediately surrounding and underneath the machine clean, neat, and free of debris and combustible materials. Keep the area above the machine clear of debris that could fall on the machine. Store the machine properly when it is not being used. Keep unauthorized personnel, children, and pets away from the machine. When operating the machine: Never operate the machine in areas that contain flammable objects, fuels, or products that produce flammable vapors. 1.3 Safety Guidelines for Lifting the Machine Lifting/ transporting the machine When lifting/transporting the machine: Make sure all lifting devices are attached securely and have enough weightbearing capacity to lift or hold the machine safely. Remain aware of the location of other people when lifting the machine. Only use the lifting points and tie-downs described in the Operator s Manual. Only use suitable transport vehicles with sufficient load-carrying capacity. When lifting the machine: Never walk or stand under a suspended machine. Never climb, sit, or stand on the machine while it is being lifted or transported. Do not operate the machine when it is being lifted or towed. ghi_si000281gb.fm 11

12 Safety Information 1.4 Safety Guidelines While Using Combustion Burners When using the machine: Clean up any spilled fuel immediately. Replace the fuel tank cap after refueling the machine. Refill the fuel tank in a well-ventilated area. Shut down the generator if equipped when refueling. When using the machine: DANGER Exhaust gas from the burner contains carbon monoxide, a deadly poison. Exposure to carbon monoxide can kill you in minutes. Never run the machine indoors or in an enclosed area unless the machine is vented properly. Do not fill or drain the fuel tank near an open flame or while the machine is running. Do not smoke when refueling the machine. 1.5 Safety Guidelines while Using Internal Combustion Engines Running the engine When running the engine: Keep the area around exhaust pipe free of flammable materials. Check the fuel lines and the fuel tank for leaks and cracks before starting the engine. Do not run the machine if fuel leaks are present or the fuel lines are loose. When running the engine: Engine exhaust CAN KILL YOU IN MINUTES. Engine exhaust contains carbon monoxide. This is a poison you cannot see or smell. Never run the machine indoors or in an enclosed area such as a deep trench unless adequate ventilation, through such items as exhaust fans or hoses, is provided. Do not smoke while operating the machine. Do not run the engine near open flames. Do not touch the engine or muffler while the engine is running or immediately after it has been turned off. Do not operate a machine when its fuel cap is loose or missing. ghi_si000281gb.fm 12

13 1.6 Safety Guidelines for Maintaining the Machine Safety Information Training Only trained personnel should troubleshoot or repair electrical problems occurring with the machine. Cleaning When cleaning and servicing the machine: Keep the area around the burner free of debris such as leaves, paper, cartons, etc. Keep the machine clean and labels legible. When cleaning the machine: Do not clean the machine while it is running. Never use gasoline or other types of fuels or flammable solvents to clean parts. Fumes from fuels and solvents can become explosive! Maintenance guidelines Replacing parts and labels When maintaining the machine: Keep the fuel lines in good condition and properly connected. Allow the burner to cool before maintaining the machine. Allow the Heat Transfer Fluid (HTF) to cool before maintaining the machine. Re-install the safety devices and guards after repairs and maintenance. Keep all electrical cords away from heat, oil, vibrating surfaces, and sharp edges. When maintaining the machine: Replace worn or damaged components. Use only spare parts recommended by Wacker Neuson Corporation. Replace all missing and hard-to-read labels. Replace or repair electrical components with components that are identical in rating and performance as the original component. When maintaining the machine: Do not attempt tire repairs. Accessories, safety devices and modifications When using the machine: Use only accessories/attachments that are recommended by Wacker Neuson Corporation. When using the machine: Never operate the machine if any safety devices or guards are missing or inoperative. Do not defeat safety devices. Do not modify the machine without the express written approval of Wacker Neuson Corporation. ghi_si000281gb.fm 13

14 Controls and Components 2 Controls and Components 2.1 External Components Ref. Description Ref. Description 1 Hitch (ball or pintle) 6 Fender 2 Tie-down 7 Onan genset (option) 3 Fuel tank 8 Jack stand 4 Fuel cap 9 Lifting bail (option) 5 Performance monitoring light ghi_tx000977gb.fm 14

15 2.2 Internal Components Controls and Components Ref. Description Ref. Description a Duplex receptacle h Hose reel and hose b Pressure and temperature gauges i Hose quick-connect c Flow gauge j Hose reel brake T-handle d Rewind system foot control pedal k Fuel filter e Temperature controller l Low-level shut-down device f Control panel m Burner g Heat Transfer Fluid (HTF) reservoir gauge n Hydronic heater ghi_tx000977gb.fm 15

16 Controls and Components 2.3 Control Panel Detail ghi_tx000977gb.fm 16

17 Troubleshooting Basics 3 Troubleshooting Basics 3.1 Where to Start The chart below lists the four basic problems the machine may experience. Refer to the chart to determine which chapter to see for each basic problem. If The machine does nothing when turned on, The machine does not heat the HTF, The machine does not circulate the HTF, The machine does not rewind the hose, Then see Chapter 4 Power Components. see Chapter 5 Heating System. see Chapter 6 Circulation System. see Chapter 7 Rewind System. ghi_tx000978gb.fm 17

18 Power Components 4 Power Components Components For any system of the machine to function, the following three power components must function properly: Power supply (supplies) Main circuit breaker(s) GFCI(s) Best practice The best practice when troubleshooting the power components is to: 1. Isolate and check each power component individually. 2. When a malfunctioning component is found, repair or replace it. This chapter of the manual provides procedures to check the power components. Testing sequence Check the function of the power components in the sequence below. 1. Power supply See Section 4.1 Checking the Power Supply. 2. Main circuit breaker See Section 4.2 Checking the Main Circuit Breaker. 3. GFCI See Section 4.3 Checking the GFCI. ghi_tx000979gb.fm 18

19 4.1 Checking the Power Supply Power Components Prerequisites One source of 120 VAC One 10-gauge, 3-wire extension cord max. 100 feet (not applicable for machines with generators) Procedure Follow the procedure below to check the power supply. 1. Check the connection of the extension cord. 2. Turn on circuit breaker 1. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 3. Open the control panel. 4. Measure the voltage between L1 and L2 (neutral) of the main terminal strip. Is VAC measured? The power supply is OK. The power source is inadequate or non-existent. Check the power source (generator or wall outlet). The power supply has now been checked. Continue with Section 4.2 Checking the Circuit Breaker. ghi_tx000979gb.fm 19

20 Power Components 4.2 Checking the Circuit Breaker Prerequisites Power supply checks OK Multimeter Procedure Follow the procedure below to check the circuit breaker. 1. Verify that the power supply is plugged in. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 2. Open the control panel. 3. Measure the voltage between the incoming side (a) of the circuit breaker and L2 (neutral) of the main terminal strip. Is VAC measured? Continue. The wiring to the circuit breaker is faulty. Disconnect the power supply and repair the wiring. 4. With the circuit breaker in the OFF position, measure the voltage between the outgoing side of the circuit breaker and L2 (neutral). Is any voltage measured? The circuit breaker has failed. Disconnect the power supply and replace the circuit breaker. Continue. 5. Place the circuit breaker in the ON position. This procedure continues on the next page. ghi_tx000979gb.fm 20

21 Power Components Continued from the previous page. 6. With the circuit breaker in the ON position, measure the voltage between the outgoing side (b) of the circuit breaker and L2 (neutral). Is VAC measured? The circuit breaker is OK. The circuit breaker has failed. Disconnect the power supply and replace the circuit breaker. The circuit breaker has now been checked. Continue with Section 4.3 Checking the GFCI. ghi_tx000979gb.fm 21

22 Power Components 4.3 Checking a GFCI Prerequisites Power supply checks OK Circuit breaker checks OK Procedure Follow the procedure below to check the GFCI. 1. Verify that the power supply is plugged in. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 2. Open the control panel. 3. Place the circuit breaker in the ON position. 4. Measure the voltage between the black wire on the incoming side (b) of the GFCI and L2 (neutral) of the main terminal strip. Is VAC measured? Continue. The black wire to the GFCI is faulty. Disconnect the power supply and repair the wiring. 5. Measure the voltage between the white and the black wires on the incoming side of the GFCI. Is VAC measured? Continue. The white wire to the GFCI is faulty. Disconnect the power supply and repair the wiring. This procedure continues on the next page. ghi_tx000979gb.fm 22

23 Power Components Continued from the previous page. 6. Push the OFF/TEST button on the face of the GFCI. Does the test light (a) of the GFCI illuminate? Continue. The GFCI has failed. Disconnect the power supply and replace the GFCI. 7. Measure the voltage between the white and the black wires on the outgoing side of the GFCI. Is VAC measured? The GFCI has failed. Disconnect the power supply and replace the GFCI. Continue. 8. Press the ON/RESET button. With the ON/RESET button pushed in, measure the voltage between the white and the black wires on the outgoing side of the GFCI. Is VAC measured? The GFCI is OK. The GFCI has failed. Disconnect the power supply and replace the GFCI. The GFCI has now been checked. Power is available to the components of the machine. If the machine still does not function, refer to Section 3.1 to determine which system and corresponding components should be checked. ghi_tx000979gb.fm 23

24 Heating System 5 Heating System 5.1 Burner Controller Periods and Modes Periods The burner controller has several periods it sequences through during normal operation. These periods are described below.. Period Power up Safety (5 seconds) Action or Function As soon as power is supplied to the burner controller, it conducts an internal safety check. If all internal conditions are OK, the burner controller enters the idle mode and will remain there until there is a call for heat or power is disconnected. When the setpoint of the temperature controller is set at a temperature higher than that of heat transfer fluid, the output contacts of the temperature controller close completing a circuit between terminal T and 3T of the burner controller. This is the call for heat. Valve-ondelay The burner controller initiates the safety period. If flame or light is detected, the burner controller remains in the idle mode and no other functions take place. If flame or light is not detected after 5 seconds: Power is sent to the burner motor/fuel pump. Fuel is pumped from the supply tank and returned to the supply tank through the return/ bypass port of the fuel pump. This process purges air from the fuel lines. Power is sent to the electrodes and any residual fuel is burned off. Fresh air fills the combustion chamber. The valve-on-delay period starts. The valve-on-delay period lasts 15 seconds. It is enabled (turned on or off) with DIP switch 3. When enabled: Power is sent to the burner motor/fuel pump. Power is sent to the electrodes. The fuel shut-off valve is energized (opens) and fuel flows to the nozzle after the valve-on-delay times out. ghi_tx000980gb.fm 24

25 Heating System Period Action or Function The trial-for-ignition period immediately follows the valve-on-delay period. During this period: The fuel shut-off valve is opened (energized). Pressurized fuel atomizes at the burner nozzle. The atomized fuel is vaporized and ignited by the electrodes. The burner fires and the flame is monitored by the cad cell. If flame is not detected: The burner controller enters lockout mode. Power is disconnected from the fuel shut-off valve, electrodes, and the burner motor. The indicator light flashes. Carry-over The ignition carry-over period starts as soon as the flame is established. During this cycle: The fuel shut-off valve is open (energized). Pressurized fuel atomizes at the burner nozzle. The atomized fuel is ignited by the electrodes The electrodes stay powered for up to 30 seconds after flame is sensed. Once the carry-over period has expired: The ignition transformer is shut off. The burner controller enters the run mode. If the flame is lost: If the lockout time has not expired, the burner controller returns to trial-for-ignition period. If the lockout time has expired, the burner controller enters the recycle mode. Trial-forignition Burner-motoroff delay The burner-motor-off-delay period starts immediately after the setpoint is reached, i.e., the call for heat has been satisfied. The time of this period is set by the DIP switches (DIP switches 1 and 2 in the down position; 3 in the up position). During this period: The fuel shut-off valve is closed (de-energized). The burner motor runs until the burner-motor-off delay expires, then the burner motor turns off. The burner controller returns to the idle mode. Non-fault modes The burner non-fault modes are described below. Mode Functional description Idle The burner controller will enter the idle mode if: At power up, the internal conditions are correct and the cad cell senses no light. The cad cell senses light during the safety period. The call for heat has been satisfied. During this mode: The burner controller powers no outputs. ghi_tx000980gb.fm 25

26 Heating System Mode Startup Run Functional description The burner controller will enter the startup mode as soon as there is a call for heat. This mode consists of the following periods: Safety Valve-on-delay Trial-for-ignition Carry-over The run mode starts and continues once the ignition carry-over period has elapsed. During this mode: The fuel shut-off valve is open (energized). Pressurized fuel atomizes at the burner nozzle. The flame is monitored by the cad cell. Once the setpoint is reached (call for heat satisfied): The output contacts of the temperature control open, interrupting the circuit between terminal T and 3T. The fuel shut-off valve is closed (de-energized). The burner motor runs for the selected burner-motor-off delay time (period), then turns off. The burner controller returns to the idle mode. If the flame is lost during the run mode: The burner controller enters the recycle mode. Recycle The burner will enter the recycle mode when the burner stops firing due to loss of flame. During the recycle mode: The diagnostic light on the burner controller will flash in twosecond intervals. The burner will attempt to automatically restart. Flame must be detected during each restart attempt. If no flame is detected, the burner controller goes into burner fault lockout mode. The burner controller will wait 60-seconds between restart attempts. If after three restart attempts in which the call for heat is not satisfied, the burner controller will go into burner fault lockout mode. If the call for heat is satisfied, the recycle counter resets. This procedure continues on the next page. ghi_tx000980gb.fm 26

27 Continued from the previous page. Heating System Fault modes The burner controller fault modes are described below. Lockout Restricted lockout The burner will enter the lockout mode after three unsuccessful attempts to re-light the flame. During the lockout mode: The burner will not fire. The diagnostic light on the burner controller will flash in halfsecond intervals. The burner fault light on the control panel will illuminate. To clear the lockout fault so a restart can be attempted, press and release the reset button. Note: After the third attempt to manually clear the lockout fault, the burner controller will enter the restricted mode. The burner will enter the restricted mode after three unsuccessful attempts to manually reset the lockout fault. During the lockout mode: The burner will not fire. The diagnostic light on the burner controller will flash in halfsecond intervals. The burner fault light on the control panel will illuminate. To clear the restricted lockout fault so a restart can be attempted, press and hold (approximately seconds) the reset button until the diagnostic light flashes once. Note: The burner will return to the lockoutmode with each unsuccessful burner restart until a successful heating cycle has occurred. ghi_tx000980gb.fm 27

28 Heating System 5.2 Heating System Troubleshooting Strategy Background The best practice when troubleshooting the heating system is to: 1. Isolate and check each component of the heating system individually. 2. When a malfunctioning component is found, repair or replace it. This chapter of the manual provides procedures to check the components of the heating system. Fundamental components Testing sequence For the heating system to function, the following three fundamental components must function properly. Burner switch Low-level shut-down device Relay K2 Before performing any troubleshooting procedures of the heating system, check the function of the fundamental components in the sequence below. Note: If power ( VAC) exists at the burner switch, it means the other fundamental components are functioning properly. In such a case, there is no need to test them. 1. Burner switch See Section 5.3 Checking the Burner Switch. 2. Low-level shut-down device See Section 5.4 Checking the Low-Level Shut-Down Device. 3. Relay K2 See Section 5.5 Checking Relay K2. If there is still a problem after the fundamental components have been verified, diagnose the type of heating system problem. See Section 5.6 Diagnosing Heating System Problems. ghi_tx000980gb.fm 28

29 Heating System 5.3 Checking the Burner Switch Prerequisites Power components check OK Power connected to the machine Procedure Follow the procedure below to check the burner switch. Note: If the burner switch is functioning properly, it means the other fundamental components are functioning properly as well. In such a case, there is no need to test the other fundamental components. 1. Open the control panel. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 2. Place circuit breaker 1 in the ON position. 3. Place the burner switch (a) in the OFF position. 4. Measure the voltage between terminal/wire 16 on the incoming side of the burner switch and L2 (neutral) of the terminal strip. Is VAC measured? If Then Yes, continue with step 5. No, one of the fundamental components has failed. Check: the low-level shut down device. See Section 5.4 Checking the Low-Level Shut-Down Device. relay K2. See Section 5.5 Checking Relay K2. This procedure continues on the next page. ghi_tx000980gb.fm 29

30 Heating System Continued from the previous page. 5. With the burner switch still in the OFF position, measure the voltage between terminal/wire 11 on the outgoing side of the burner switch and L2 (neutral) of the terminal strip. Is VAC measured? The burner switch has failed. Disconnect the power supply and replace the burner switch. Continue. 6. Place the burner switch in the ON position. 7. Measure the voltage between terminal/wire 11 on the outgoing side of the burner switch and L2 (neutral) of the terminal strip. Is VAC measured? The burner switch and all fundamental components are OK. The burner switch has failed. Disconnect the power supply and replace the burner switch. The burner switch has now been checked. If the heating system still does not function, continue with Section 5.4 Checking the Low-Level Shut-Down Device. ghi_tx000980gb.fm 30

31 Heating System 5.4 Checking the Low-Level Shut-Down Device Prerequisites All power components check OK Multimeter Procedure Follow the procedure below to check the low-level shut-down device. 1. Check the level of the HTF on the sight gauge. Add HTF as necessary. WARNING Electric shock hazard. High voltage exists inside the low-level shut-down device. High voltage can cause severe injury or death. Use extreme care when working inside the low-level shut-down device. 2. Place circuit breaker 1 in the OFF position. 3. Open the side panel and locate the low-level shut down device (a). 4. Remove the cover from the low-level shut-down device. 5. Remove the wing nut and the probe wire from the probe (b). 6. Measure the resistance between the end of the probe and ground (bare metal location on the heater unit). Is resistance measured? Continue. The probe has failed; replace it. This procedure continues on the next page. ghi_tx000980gb.fm 31

32 Heating System Continued from the previous page. 7. Place circuit breaker 1 in the ON position. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 8. Measure the voltage between black wire 1 of the low-level shut-down device and L2 (neutral) of the terminal strip. Then, measure between orange wire 1 of the low-level shut down device and L2 (neutral) of the terminal strip. Is VAC measured in each case? Continue. The wiring (orange 1 or black 1) is faulty. Disconnect the power supplies and repair the wiring. 9. Measure the voltage between the black wire 1 and the white wire/terminal of the low-level shut-down device. Is VAC measured? Continue. The white wire is faulty. Disconnect the main power supplies and repair the wiring. 10.Measure the voltage between red wire 5 of the low-level shut down device and L2 (neutral) of the terminal strip. Is VAC measured? The low-level shutdown device is OK. The low-level shut-down device has failed. Disconnect the power supplies and replace the low-level shutdown device. The low-level shut-down device has now been checked. Continue with Section 5.5 Checking Relay K2. ghi_tx000980gb.fm 32

33 Heating System 5.5 Checking Relay K2 Prerequisites All power components check OK Multimeter Procedure Follow the procedure below to check relay K2. 1. Place circuit breaker 1 in the OFF position. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 2. Open the control panel. 3. Locate relay K2 (c). 4. Label, then disconnect the wires from relay K2. 5. Measure the resistance across the coil of the relay (terminals 0 and 1). Is ohms measured? Continue. Relay K2 has failed; replace it. 6. Measure the resistance (check continuity) across normally closed contacts terminals 3 and 4. Is approximately 0.1 ohms measured? Continue. Relay K2 has failed; replace it. 7. Measure the resistance (check continuity) across normally open contacts terminals 2 and 4. Is approximately 0.1 ohms measured? Relay K2 has failed; replace it. Continue. This procedure continues on the next page. ghi_tx000980gb.fm 33

34 Heating System Continued from the previous page. 8. Reconnect the wiring to relay K2. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 9. Place circuit breaker 1 in the ON position and wait one minute. 10.Measure the voltage between the incoming side of the burner switch (a) and L2 (neutral) of the terminal strip. Is VAC measured? Continue. Relay K2 has failed. Disconnect the power supplies and replace relay K2. 11.Measure the voltage between the incoming side (wire 17) of the low-level fault light (b) and L2 (neutral) of the terminal strip. Is VAC measured? Disconnect the power supplies and replace relay K2. Relay K2 is OK. Relay K2 has now been checked. The fundamental components of the heating system are OK. If the heating system still does not function, see Section 5.6 Diagnosing Heating System Problems. ghi_tx000980gb.fm 34

35 5.6 Diagnosing Heating System Problems Heating System Prerequisites All power components check OK All fundamental components check OK Procedure Follow the procedure below to determine which component(s) of the heating system to check. 1. Place circuit breaker 1 and circuit breaker 2 in the ON position. 2. Place the burner switch in the ON position. 3. Set the temperature controller to 180 F. Does the display of the temperature controller and LED C1 (a) illuminate? Continue. See Section 5.7 Checking the Temperature Controller. 4. Observe the burner fault light on the control panel. Does the BURNER FAULT light illuminate? Continue. There is a problem with one of the three components below. Verify the wiring to, and function of, each component. See the following sections in order: Section 5.8/5.9 Checking the Burner Controller Section 5.17/5.18 Checking Relay K1 Section 8.2 Checking an Indicator Light This procedure continues on the next page. ghi_tx000980gb.fm 35

36 Heating System Continued from the previous page. 5. Locate the primary control (a). 6. Push the red reset button (b) on the primary control for 45 seconds and release. Does the burner attempt to start? Continue. 7. If the burner attempted to start, follow the guide below. If Ignition occurs and the burner stays lit, Ignition occurs then stops after approximately 20 seconds of blower run time, Ignition does not occur and the blower stops after approximately 20 seconds of blower run time, The procedure is now complete. The problem is one of the three components below. Verify the wiring to, and function of, each component. See the following sections in order: Section 5.8/5.9 Checking the Burner Controller Section 5.10 Checking the Snap Disc Section 5.11 Checking the Burner Fan Motor Then use machine as normal. the problem is the cad cell. See Section 5.12 Checking the Cad Cell. the problem is one of the components below. Verify the wiring to, and function of, each component. See the following sections in order: Section 5.13 Checking the Oil Valve Section 5.14 Checking the Fuel Filter Section 9.3 Checking/Replacing the Burner Nozzle Section 5.15 Checking the Ignition Transformer Section 9.2 Checking/Setting the Electrodes ghi_tx000980gb.fm 36

37 5.7 Checking the Temperature Controller Heating System Prerequisites Power components check OK Fundamental components check OK Procedure Follow the procedure below to check the temperature controller. 1. Place circuit breaker 1 in the ON position. 2. Observe the temperature controller. Does the temperature controller read UUUU or 5ERR? Check the connection of the thermocouple wires (terminals 17 & 18). Make sure the blue wire is connected to terminal 17; red to terminal 18. If the controller still reads UUUU or 5ERR see Section 5.16 Checking the Thermocouple. Continue. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 3. Open the control panel and locate the back of the temperature controller (b). 4. Place circuit breaker 1 in the OFF position. 5. Check continuity between the wire connected to terminal 6 of the temperature controller and neutral (L2 on the terminal strip). There must be continuity (0.1 Ohms). Repair or replace the wire as needed. 6. Place circuit breaker 1 in the ON position. 7. Place the burner switch in the ON position. 8. Measure the voltage between wire 1 connected to terminal 5 of the temperature controller and neutral (L2 on the terminal strip). Is VAC measured? Continue. Disconnect the power supplies and repair wire 1. This procedure continues on the next page. ghi_tx000980gb.fm 37

38 Heating System Continued from the previous page. 9. Adjust the temperature controller to 180 F by pressing the UP arrow. 10.Check the LED C1 (a) on the front face of the temperature controller. Does the LED C1 and the readout display illuminate? Continue. The temperature controller has failed. Disconnect the power supplies and replace the temperature controller. 11.Disconnect the wires from terminals 14 and With the temperature controller still set at 180 F, measure the resistance (continuity) across the terminals. Is 0.1 ohms measured? The temperature controller should be OK. If you suspect a problem with the programming of the temperature controller, see Appendix. The temperature controller has failed. Disconnect the power supplies and replace the temperature controller. The temperature controller has now been checked. If the heating system still does not function, continue with Section 5.8/5.9 Checking the Burner Controller. ghi_tx000980gb.fm 38

39 5.8 Checking the Burner Controller (SN 1538 and higher) Prerequisites Power components check OK Fundamental components check OK Heating System Procedure Follow the procedure below to check power to the burner controller. 1. Place circuit breaker 1 in the ON position. 2. Set the temperature controller to 50 F. 3. Place the burner switch in the ON position. 4. Measure the voltage between terminal T and terminal 3T of the burner controller. Is VAC measured? Continue. The wiring between the temperature controller and the burner controller may have failed. Check the wiring. 5. Place circuit breaker 1 in the OFF position. 6. Remove the burner controller by loosening screws (c). INTRPT/IGNITER BURNER/MOTOR L1 L2 L2 L2 L2 CAD CELL 2 LIMIT VALVE 7. Check the connections and the continuity of white wire 2 that runs between the L2 terminal of the burner controller and the terminal strip. This procedure continues on the next page. ghi_tx000980gb.fm 39

40 Heating System Continued from the previous page. Does the wire have continuity? Continue. Wire 2 between the L2 terminal and the terminal strip has failed; replace it. 8. Place circuit breaker 1 in the ON position. WARNING Electric shock hazard. High voltage exists inside the burner controller. High voltage can cause severe injury or death. Use extreme care when working inside the burner controller. 9. Place the burner switch in the ON position. 10.Measure the voltage between wire 11 (at the LIMIT terminal) and any L2 terminal of the burner controller. Continue. Wire 11 between the LIMIT terminal and the burner switch has failed. Disconnect the power supplies and repair wire Measure the voltage between wire 1 (at the L1 terminal) and any L2 terminal of the burner controller. Is VAC measured? Continue. Wire 1 has failed. Disconnect the power supplies and repair wire 1. This procedure continues on the next page. ghi_tx000980gb.fm 40

41 Heating System Continued from the previous page. 12.Turn OFF and then back ON the burner switch. After the burner purge cycle, measure the voltage between the INTRPT/IGNITER terminal and any L2 terminal. Is VAC measured? Continue. 13.Continue with the burner switch in the ON position, 14.Measure the voltage between the BURNER/MOTOR terminal and any L2 terminal. Is VAC measured? Continue. 15.Measure the voltage between the VALVE terminal and any L2 terminal. Is VAC measured? The burner controller is OK. The burner controller has failed. Disconnect the power supplies and replace the burner controller. The burner controller has failed. Disconnect the power supplies and replace the burner controller. The burner controller has failed. Disconnect the power supplies and replace the burner controller. Is VAC measured? The burner controller is OK. The burner controller has failed. Disconnect the power supplies and replace the burner controller. The burner controller has now been checked. If the heating system still does not function, continue with Section 5.10 Checking the Snap Disc. ghi_tx000980gb.fm 41

42 Heating System 5.9 Checking the Burner Controller (SN 1537 and lower) Prerequisites Power components check OK Fundamental components check OK Procedure Follow the procedure below to check the burner controller. 1. Place circuit breaker 1 in the ON position. 2. Set the temperature controller to 50 F. 3. Place the burner switch in the ON position. 4. Measure the voltage between terminal T and terminal 3T of the burner controller. Is VAC measured? Continue. The wiring between the temperature controller and the burner controller may have failed. Check the wiring. 5. Place circuit breaker 1 in the OFF position. 6. Remove the burner controller by loosening screws (c). INTRPT/IGNITER BURNER/MOTOR L1 L2 L2 L2 L2 CAD CELL 2 LIMIT VALVE 7. Check the connections and the continuity of wire 2 that runs between the L2 terminal of the burner controller and the terminal strip. This procedure continues on the next page. ghi_tx000980gb.fm 42

43 Heating System Continued from the previous page. Does the wire have continuity? Continue. Wire 2 between the L2 terminal and the terminal strip has failed; replace it. WARNING Electric shock hazard. High voltage exists inside the burner controller. High voltage can cause severe injury or death. Use extreme care when working inside the burner controller. 8. Place circuit breaker 1 in the ON position. 9. Place the burner switch in the ON position. 10.Measure the voltage between wire 11 (at the LIMIT terminal) and any L2 terminal of the burner controller. Is VAC measured? Continue. Wire 11 between the LIMIT terminal and the burner switch has failed. Disconnect the power supplies and repair wire Measure the voltage between wire 1 (at the L1 terminal) and L2 of the burner controller. Is VAC measured? Continue. Wire 1 between the L1 terminal and the burner switch has failed. Disconnect the power supplies and repair wire 1. This procedure continues on the next page. ghi_tx000980gb.fm 43

44 Heating System Continued from the previous page. 12.Turn OFF and then back ON the burner switch. After the burner purge cycle, measure the voltage between the INTRPT/IGNITER terminal and any L2 terminal. Is VAC measured? Continue. 13.Continue with the burner switch in the ON position. 14.Measure the voltage between the BURNER/MOTOR terminal and any L2 terminal. Is VAC measured? Continue. 15.Measure the voltage between the VALVE terminal and any L2 terminal. Is VAC measured? The burner controller is OK. The burner controller has failed. Disconnect the power supplies and replace the burner controller. The burner controller has failed. Disconnect the power supplies and replace the burner controller. The burner controller has failed. Disconnect the power supplies and replace the burner controller. The burner controller has now been checked. If the heating system still does not function, continue with Section 5.10 Checking the Snap Disc. ghi_tx000980gb.fm 44

45 Heating System 5.10 Checking the Snap Disc (Thermal Limit) Prerequisites Machine cool Multimeter Procedure Follow the procedure below to check the snap disc. WARNING Burn hazard. The furnace chamber is hot when the machine is operating. If touched, it may cause severe burns. Allow the furnace chamber to cool before performing this test. 1. Place circuit breaker 1 in the OFF position. 2. Locate the snap disc. It is located in a housing (a) mounted to the side of the furnace chamber. 3. Reset the snap disc by pushing the reset button (B) in. 4. Remove the face plate of the housing. 5. Remove the two wires that lead to the snap disc. 6. Measure the resistance across the terminals of the snap disc. Is approximately 0.1 ohms measured? Continue. The snap disc has failed; replace it. This procedure continues on the next page. ghi_tx000980gb.fm 45

46 Heating System Continued from the previous page. 7. Re-attach the wires to the snap disc. 8. Remove the primary control by loosening the screws (d). 9. Among the wires of the primary control junction box, locate the wire that runs from the primary control to the snap disc (e). Also locate the wire that runs from the snap disc to the burner motor. Disconnect each wire. 10.Measure the resistance between the two wires that run to the snap disc. Is approximately 0.1 ohms measured? The snap disc and its wiring are OK. The wiring to the snap disc has failed; replace it. The procedure to check the snap disc is now complete. If the heating system still does not function, continue with Section 5.11 Checking the Burner Fan Motor. ghi_tx000980gb.fm 46

47 Heating System 5.11 Checking the Burner Fan Motor Prerequisites Power Components check OK Multimeter Procedure Follow the procedure below to check the burner fan motor. 1. Remove the primary control by loosening screws (c). INTRPT/IGNITER BURNER/MOTOR L1 L2 L2 L2 L2 CAD CELL 2 LIMIT VALVE 2. Locate and remove the orange wire and the white wire (that power the burner fan motor) from the primary control. 3. Measure the resistance between the orange wire and white wire. Is Ohms measured? Continue. The burner fan motor has failed; replace it. 4. Measure the resistance between one of the wires and ground. Is infinity Ohms (OL) measured? Continue. The burner fan motor has failed; replace it. 5. Reconnect the orange wire. 6. Place circuit breaker 1 in the ON position. WARNING Electric shock hazard. High voltage exists on the burner motor when the burner switch is in the ON position. High voltage can cause severe injury or death. Use extreme care when working on the burner fan motor. 7. Place the burner switch in the ON position. 8. Measure the voltage between the white wire and L2 of the terminal strip. Is VAC measured? The burner fan motor is OK. The burner fan motor has failed; replace it. The burner fan motor has now been checked. If the heating system still does not function, review Section 5.6 Diagnosing Heating System Problems. ghi_tx000980gb.fm 47

48 Heating System 5.12 Checking the Cad Cell Prerequisites Power disconnected from the machine Multimeter Procedure Follow the procedure below to check the cad cell. 1. Remove the primary control by loosening screws (c). 2. Loosen tabs (b) and hinge back the igniter plate cover. 3. Disconnect the yellow wires (d) from the bottom of the primary control. 4. Measure the resistance of the cad cell (e) by measuring across the yellow wires. Be sure the cad cell is exposed to light. Is ohms measured? Continue. The cad cell is dirty or defective. First, clean the glass eye, then re-measure. If the reading remains out of the range listed above, replace the cad cell. This procedure continues on the next page. ghi_tx000980gb.fm 48

49 Continued from the previous page. Heating System 5. Deprive the cad cell of light (cover the cad cell) and measure the resistance again. Is 20,000 50,000 ohms measured? The cad cell is OK. The cad cell is dirty or defective. First, clean the glass eye, then re-measure. If the reading remains out of the range listed above, replace the cad cell. The procedure to check the cad cell is now complete. ghi_tx000980gb.fm 49

50 Heating System 5.13 Checking the Oil Valve Prerequisites Power components check OK Fundamental components check OK Procedure Follow the procedure below to check the oil valve. 1. Remove the primary control by loosening screws (c). INTRPT/IGNITER BURNER/MOTOR L1 L2 L2 L2 L2 CAD CELL 2 LIMIT VALVE 2. Place circuit breaker 1 in the ON position. 3. Position all dipswitches (a) in the down or disabled position. 4. Remove the oil valve electrical plug (b). WARNING Electric shock hazard. High voltage exists at the oil valve plug when the burner switch is in the ON position. High voltage can cause severe injury or death. Do not touch the receptacles of the electrical plug. 5. Place the burner switch in the ON position. This procedure continues on the next page. ghi_tx000980gb.fm 50

51 Heating System Continued from the previous page. 6. Measure the voltage at the electrical plug. Is VAC measured? Continue. The wiring to the oil valve has failed. Disconnect the power supplies and replace the wiring. 7. Place circuit breaker 1 in the OFF position. 8. Measure the resistance between the male terminals on the solenoid body. Is ohms measured? The oil valve is OK. The solenoid has failed; replace it. 9. Position the dip switches back to the original position. The oil valve has now been checked. If the heating system still does not function, continue with Section 5.14 Checking the Fuel Filter. ghi_tx000980gb.fm 51

52 Heating System 5.14 Checking the Fuel Filter Prerequisites Power components check OK Fundamental components check OK Removal procedure Follow the procedure below to check/change the fuel filter. 1. Place circuit breaker 1 in the OFF position. 2. Locate the fuel filter assembly (a). 3. Disconnect both quick-connect couplings (b and c). Note: Fuel is within the fuel filter canister. Take measures to capture any fuel that spills. Dispose of this fuel in accordance with local environmental regulations. 4. Remove the bolt (d) from the top of the canister cap and remove the canister cap. 5. Remove the fuel filter (e) and the gasket (f). 6. Clean the inside of the canister. Installation procedure Follow the procedure below to install the fuel filter. 1. Install a new gasket to the canister. 2. Install a new fuel filter into the canister. Be sure to align the fuel filter properly with the bottom of the canister. 3. Re-install the canister cap and secure it with the bolt. 4. Reconnect the quick-connect couplings. The fuel filter has now been checked. If the heating system still does not function, continue with Section 5.15 Checking the Ignition Transformer. ghi_tx000980gb.fm 52

53 Heating System 5.15 Checking the Ignition Transformer Prerequisites Power components check OK Fundamental components check OK Procedure Follow the procedure below to check the ignition transformer. WARNING Electric shock hazard. High voltage exists at the igniter when the machine is powered. High voltage can cause severe injury or death. Use extreme care when working on the ignition transformer. 1. Open the primary control by loosening screws (a). 2. Position all dip switches (d) on in the down or disabled position. 3. Place circuit breaker 1 in the ON position. 4. Place the burner switch in the ON position. 5. Measure the voltage between terminal INTRPT/IGNITER and the wire at L2. Is VAC measured? Continue. Check that the wire from L2 has continuity to Neutral of terminal strip. If it does, the primary control has failed. Shut down the machine and replace the primary control. This procedure continues on the next page. ghi_tx000980gb.fm 53

54 Heating System Continued from the previous page. 6. Place circuit breaker 1 in the OFF position. 7. Loosen tabs (b) and hinge back the ignitor plate cover (c). 8. Measure the resistance between the blue/white striped wire and the white wire which are connected to the ignition transformer. Is approximately 7 megohms measured? Continue. The ignition transformer has failed; replace it. 9. Measure the resistance from spring to spring. The springs are located on the bottom of the igniter plate. Is ohms measured? The ignition transformer is OK. If there is no spark, see Section 9.2 Setting/Checking the Electrodes. The ignition transformer has failed. Shut down the machine and replace the ignition transformer. The ignition transformer has now been checked. If the heating system still does not function, continue with Section 9.2 Setting/Checking the Electrodes. Re-assemble the machine. ghi_tx000980gb.fm 54

55 Heating System 5.16 Checking the Thermocouple Prerequisites Power components check OK Fundamental components check OK Procedure Follow the procedure below to check the thermocouple. 1. Place circuit breaker 1 in the ON position. 2. Observe the temperature controller. Is the temperature controller displaying the setpoint temperature and the actual temperature as a positive number between 50 and 180 F? The thermocouple/connections are OK. Continue. 3. Place circuit breaker 1 in the OFF position. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 4. Open the control panel and locate the temperature controller. 5. Check the red and blue wires connected to the temperature controller. Clean the wires and terminals if any corrosion is found. This procedure continues on the next page. ghi_tx000980gb.fm 55

56 Heating System Continued from the previous page. 6. Locate the thermocouple housing (a). 7. Remove the cover of the thermocouple housing. 8. Check the connections of the wiring. Disconnect the wires and clean the wires and terminals if any corrosion exists. Reconnect the wires. 9. Place circuit breaker 1 in the ON position. Is the temperature controller displaying the setpoint temperature and the actual temperature as a positive number between 50 and 180 F? The thermocouple/connections are OK. The thermocouple has failed. Disconnect the power sources and replace the thermocouples. The thermocouple has now been checked. If the heating system still does not function, continue with Section 5.17/5.18 Checking Relay K1. Re-assemble the machine. ghi_tx000980gb.fm 56

57 Heating System 5.17 Checking Relay K1 (SN 1538 and higher) Prerequisites Power components check OK All components of the rewind system check OK Burner primary control checks OK Procedure Follow the procedure below to check relay K1. 1. Place circuit breaker 1 in the OFF position. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 2. Open the control panel. 3. Locate relay K1 (a). 4. Label, then disconnect the wires from relay K1. 5. Measure the resistance across the coil of the relay, terminals 8 and 7. Is ohms measured? Continue. Relay K1 has failed; replace it 6. Measure the resistance (check continuity) across normally closed contacts terminals 5 and 1. Is approximately 0.1 ohms measured? Continue. Relay K1 has failed; replace it This procedure continues on the next page. ghi_tx000980gb.fm 57

58 Heating System Continued from the previous page. 7. Measure the resistance across normally open contacts terminals 5 and 3. Is approximately 0.1 ohms measured? Relay K1 has failed; replace it Continue. 8. Reconnect the wiring to relay K1. WARNING Electric shock hazard. High voltage exists inside the burner. High voltage can cause severe injury or death. Use extreme care when working inside the burner. 9. Loosen tabs (b) and hinge back the igniter plate cover. 10.Simulate a burner fault by disconnecting the cad cell (c). 11.Place circuit breaker 1 in the ON position. 12.Place the burner switch in the ON position. 13.Measure the voltage at the duplex receptacle. Is any voltage measured? Relay K1 has failed. Disconnect the power supplies and replace relay K1. Continue. 14.Measure the voltage between the incoming side (wire 23) of the burner fault light and L2 (neutral) of the terminal strip. Is VAC measured (or is burner fault light on)? Relay K1 is OK. Disconnect the power supplies and re-assemble the machine. Relay K1 has failed. Disconnect the power supplies and replace relay K1. Relay K1 has now been checked. ghi_tx000980gb.fm 58

59 Heating System 5.18 Checking Relay K1 (SN 1537 and lower) Prerequisites Power components check OK All components of the rewind system check OK Burner primary control checks OK Procedure Follow the procedure below to check relay K1. 1. Place circuit breaker 1 in the OFF position. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 2. Open the control panel. 3. Locate relay K1 (a). 4. Label, then disconnect the wires from relay K1. 5. Measure the resistance across the coil of the relay (wires 14 and 2). Is 35 45k ohms measured? Continue. Relay K1 has failed. Disconnect the power supplies and replace relay K1. 6. Measure the resistance (check continuity) across normally closed contacts, terminals COM and NC. Is approximately 0.1 ohms measured? Continue. Relay K1 has failed. Disconnect the power supplies and replace relay K1. This procedure continues on the next page. ghi_tx000980gb.fm 59

60 Heating System Continued from the previous page. 7. Reconnect the wiring to relay K1. WARNING Electric shock hazard. High voltage exists inside the burner. High voltage can cause severe injury or death. Use extreme care when working inside the burner. 8. Loosen tabs (b) and hinge back the igniter plate cover. 9. Simulate a burner fault by disconnecting the cad cell (c). 10.Place circuit breaker 1 in the ON position. 11.Place the burner switch in the ON position. 12.Measure the voltage at the duplex receptacle. Is any voltage measured? Relay K1 has failed. Disconnect the power supplies and replace relay K1. Relay K1 is OK. Disconnect the power supplies and re-assemble the machine. Relay K1 has now been checked. ghi_tx000980gb.fm 60

61 Circulation System 6 Circulation System 6.1 Diagnosing the Circulation System Background Procedure There are two types of problems that the circulation system may experience: A mechanical problem with the HTF filter or with the HTF pump An electrical problem with a component within the system Follow the procedure below to determine the type of circulation problem. 1. Place circuit breaker 1 in the ON position. 2. Place the pump switch in the ON position. Does the pump run? Continue. See Section 6.2 Troubleshooting the Circulation System 3. Observe the flow meter and pressure gauge. If There is high pressure and low flow, There is low pressure and low flow, Then the hose is pinched or kinked. Check the hose. the HTF filter is clogged, or the pump has failed. Check the HTF filter (see Section Changing a HTF Filter). If the HTF filter is OK, replace the HTF pump (see Section 10.9 Replacing an HTF Pump Motor). The procedure is now complete. ghi_tx000981gb.fm 61

62 Circulation System 6.2 Troubleshooting the Circulation System Background The best practice when troubleshooting the circulation system is to: 1. Isolate and check each component of the heating system individually. 2. When a malfunctioning component is found, repair or replace it. 3. After replacing a malfunctioning component, retry system operation. This chapter of the manual provides procedures to check the components of the circulation system. Fundamental components Testing sequence For the circulation pump to function, the following three fundamental components must function properly. Pump switch Low-level shut-down device Relay K2 Before starting any troubleshooting procedures, check the function of the fundamental components in the sequence below. Note: If power ( VAC) exists at the pump switch, it means the low-level shut-down device and relay K2 are functioning properly. In such a case, there is no need to test them. 1. Pump switch See Section 6.3 Checking the Pump Switch. 2. Low-level shut-down device See Section 6.4 Checking the Low-Level Shut-Down Device. 3. Relay K2 See Section 6.5 Checking Relay K2. After the fundamental components have been verified, check the pump motor. See Section 6.6 Checking the Pump Motor. ghi_tx000981gb.fm 62

63 Circulation System 6.3 Checking the Pump Switch Prerequisites Power components check OK Power connected to the machine Procedure Follow the procedure below to check the pump switch. Note: If power ( VAC) exists at the pump switch, it means the low-level shut-down device and relay K2 are functioning properly. In such a case, there is no need to test them. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 1. Open the control panel. 2. Place circuit breaker 1 in the ON position. 3. Place the pump switch (a) in the OFF position. 4. Measure the voltage between the incoming side (wire 16) of the pump switch and L2 (neutral) of the main terminal strip. Is VAC measured? Continue. The relay K2 may have failed. Check relay K2. 5. With the pump switch still in the OFF position, measure the voltage between the outgoing side (wire 9) of the pump switch and L2 (neutral) of the main terminal strip. Is any voltage measured? The pump switch has failed. Disconnect the power supply and replace the pump switch. Continue. This procedure continues on the next page. ghi_tx000981gb.fm 63

64 Circulation System Continued from the previous page. 6. Place the pump switch in the ON position 7. Measure the voltage between the outgoing side (wire 9) of the pump switch and L2 (neutral) of the main terminal strip. Is VAC measured? The pump switch and the fundamental components of the circulation system are OK. The pump switch has failed. Disconnect the power supply and replace the pump switch. The procedure to check the pump switch is now complete. If the machine still does not circulate HTF, see Section 6.4 Checking the Low-Level Shut-Down Device. ghi_tx000981gb.fm 64

65 Circulation System 6.4 Checking the Low-Level Shut-Down Device Prerequisites All power components check OK Multimeter Procedure Follow the procedure below to check the low-level shut-down device. 1. Check the level of the HTF on the sight gauge. Add HTF as necessary. WARNING Electric shock hazard. High voltage exists inside the low-level shut-down device. High voltage can cause severe injury or death. Use extreme care when working inside the low-level shut-down device. 2. Place circuit breaker 1 in the OFF position. 3. Open the side panel and locate the low-level shut-down device (a). 4. Remove the cover from the low-level shut-down device. 5. Remove the wing nut and the probe wire from the probe (b). 6. Measure the resistance between the end of the probe and ground (bare metal location on the heater unit). Is resistance measured? Continue. The probe has failed; replace it. This procedure continues on the next page. ghi_tx000981gb.fm 65

66 Circulation System Continued from the previous page. 7. Place circuit breaker 1 in the ON position. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 8. Measure the voltage between black wire 1 of the low-level shut-down device and L2 (neutral) of the terminal strip. Then, measure between orange wire 1 of the low-level shut-down device and L2 (neutral) of the terminal strip. Is VAC measured in each case? Continue. The wiring (orange 1 or black 1) is faulty. Disconnect the power supplies and repair the wiring. 9. Measure the voltage between the black wire 1 and the white wire/terminal of the low-level shut-down device. Is VAC measured? Continue. The white wire is faulty. Disconnect the main power supplies and repair the wiring. 10.Measure the voltage between red wire 5 of the low-level shut-down device and L2 (neutral) of the terminal strip. Is VAC measured? The low-level shutdown device is OK. The low-level shut-down device has failed. Disconnect the power supplies and replace the low-level shutdown device. The low-level shut-down device has now been checked. If the circulation system still does not function, see Section 6.5 Checking Relay K2. ghi_tx000981gb.fm 66

67 Circulation System 6.5 Checking Relay K2 Prerequisites All power components check OK Multimeter Procedure Follow the procedure below to check relay K2. 1. Place circuit breaker 1 in the OFF position. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 2. Open the control panel. 3. Locate relay K2 (c). 4. Label, then disconnect the wires from relay K2. 5. Measure the resistance across the coil of the relay (terminals 0 and 1). Is Ohms measured? Continue. Relay K2 has failed; replace it. 6. Measure the resistance (check continuity) across normally closed contacts terminals 3 and 4. Is approximately 0.1 ohms measured? Continue. Relay K2 has failed; replace it. 7. Measure the resistance (check continuity) across normally open contacts terminals 2 and 4. Is approximately 0.1 ohms measured? Relay K2 has failed; replace it. Continue. This procedure continues on the next page. ghi_tx000981gb.fm 67

68 Circulation System Continued from the previous page. 8. Reconnect the wiring to relay K2. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 9. Place circuit breaker 1 in the ON position and wait one minute. 10.Measure the voltage between the incoming side of the burner switch (a) and L2 (neutral) of the terminal strip. Is VAC measured? Continue. Relay K2 has failed. Disconnect the power supplies and replace relay K2. 11.Measure the voltage between the incoming side (wire 17) of the low-level fault light (b) and L2 (neutral) of the terminal strip. Is VAC measured? Relay K2 has failed. Disconnect the power supplies and replace relay K2. Relay K2 is OK. Relay K2 has now been checked. If the machine still does not circulate HTF, see Section 6.6 Checking the Pump Motor. ghi_tx000981gb.fm 68

69 6.6 Checking the Pump Motor Circulation System Prerequisites Power components check OK Fundamental components check OK Procedure Follow the procedure below to check the pump motor. 1. Start this test with circuit breaker 1 in the OFF position. 2. Remove the stack (a) and the side panel (b) and locate the pump (c). Note: Several different styles of motors have been used. Your motor may differ slightly from those shown. This procedure continues on the next page. ghi_tx000981gb.fm 69

70 Circulation System Continued from the previous page. 3. Remove the cover plate from the junction box. 4. Disconnect the white wire. WARNING Electric shock hazard. High voltage exists inside the pump motor junction boxes. High voltage can cause severe injury or death. Use extreme care when working inside the pump motor junction boxes. 5. Place circuit breaker 1 in the ON position. 6. Measure the voltage between the black wire of the pump and L2 (neutral) of the terminal strip. Is VAC measured? Continue. The wiring to the pump motor has failed. Disconnect the power supplies and repair the wiring. 7. Measure the voltage between the white wire and the black wire. Is VAC measured? Reconnect the wiring. If the pump motor does not run, it has failed. Disconnect the power supplies and replace the pump motor. The white wire has failed. Disconnect the power supplies and repair the white wire. The pump motor has now been checked. Re-assemble the machine. ghi_tx000981gb.fm 70

71 7 Rewind System 7.1 Troubleshooting the Rewind System Rewind System Best practice The best practice when troubleshooting the rewind system is to: 1. Isolate and check each component of the rewind system individually. 2. When a malfunctioning component is found, repair or replace it. 3. After replacing a malfunctioning component, retry system operation. This chapter of the manual provides procedures to check the components of the rewind system. Mechanical components When diagnosing rewind system problems, first rule out problems with the mechanical components. If Then The rewind motor runs and the rewind clutch solenoid activates (a distinct click can be heard), but the system still won t function, there is a mechanical problem. See Section 7.12 Checking the Rewind System Mechanical Components. For all other scenarios, see the chart below. Electrical components Check the components in the sequence listed below. 1. Fuse 1 and Fuse 2 See Section 7.2 Checking Fuse 1 and Fuse Hose rewind switch See Section 7.3/7.4 Checking the Rewind Switch. 3. Rewind motor See Section 7.5 Checking the Rewind Motor. 4. Rewind clutch solenoid See Section 7.6 Checking the Rewind Clutch (Solenoid). 5. Rewind transformer See Section 7.7/7.8 Checking the Rewind Transformer. 6. Rectifier See Section 7.9/7.10 Checking the Rectifier. 7. Foot switch See Section 7.11 Checking the Foot Switch. ghi_tx000982gb.fm 71

72 Rewind System 7.2 Checking Fuse 1 and Fuse 2 Prerequisites Power supply disconnected Replacement fuses, if necessary Procedure Follow the procedure below to check fuse 1 and fuse Disconnect the power supply. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Disconnect the power supplies before conducting this test. 2. Open the control panel and locate the fuse holders (a). 3. Open the cover for fuse 1 and inspect fuse 1 (b). 4. Replace fuse 1 if it is blown, or re-install fuse Repeat the procedure for fuse 2 (c). Fuse 1 and fuse 2 have now been checked. If the rewind system still does not function, see section 7.3/7.4 Checking the Rewind Switch. ghi_tx000982gb.fm 72

73 Rewind System 7.3 Checking the Rewind Switch (SN 1538 and higher) Prerequisites Power components checks OK Fuse 1 checks OK Procedure Follow the procedure below to check the rewind switch. 1. Place circuit breaker 1 in the ON position. 2. Place the rewind switch in the ON position. Does the rewind motor run? The rewind switch is OK. Continue. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 3. Open the control panel. 4. Measure the voltage between the incoming side of the rewind switch (wire 15) and L2 (neutral) of the terminal strip. Is VAC measured? Continue. The wiring between fuse 1 and the rewind switch has failed. Disconnect the power supply and repair the wiring. 5. With the rewind switch still in the OFF position, measure the voltage between the outgoing side of the rewind switch (wire 22) and L2 (neutral) of the terminal strip. Is VAC measured? The rewind switch has failed. Disconnect the power supply and replace the rewind switch. Continue. This procedure continues on the next page. ghi_tx000982gb.fm 73

74 Rewind System Continued from the previous page. 6. Place the rewind switch in the ON position. 7. Measure the voltage between the outgoing side (wire 22) of the rewind switch and L2 (neutral) of the terminal strip Is VAC measured? The rewind switch is OK. The rewind switch has failed. Disconnect the power supply and replace the rewind switch. The rewind switch has now been checked. If the rewind system still does not function, see section 7.5 Checking the Rewind Motor. ghi_tx000982gb.fm 74

75 Rewind System 7.4 Checking the Rewind Switch (SN 1537 and lower) Prerequisites Power components check OK Fuse 1 checks OK Procedure Follow the procedure below to check the rewind switch. 1. Place circuit breaker 1 in the ON position. 2. Place the rewind switch in the ON position. Does the rewind motor run? The rewind switch is OK. Continue. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 3. Open the control panel. 4. Measure the voltage between the incoming side of the rewind switch (wire 22) and L2 (neutral) of the terminal strip. Is VAC measured? Continue. The wiring between fuse 1 and the rewind switch has failed. Disconnect the power supplies and repair the wiring. 5. With the rewind switch still in the OFF position, measure the voltage between the outgoing side (wire 15) of the rewind switch and L2 (neutral) of the terminal strip. Is VAC measured? The rewind switch has failed. Disconnect the power supplies and replace the rewind switch. Continue. This procedure continues on the next page. ghi_tx000982gb.fm 75

76 Rewind System Continued from the previous page. 6. Place the rewind switch in the ON position. 7. Measure the voltage between the outgoing side of the rewind switch (wire 15) and L2 (neutral) of the terminal strip. Is VAC measured? The rewind switch is OK. The rewind switch has failed. Disconnect the power supplies and replace the rewind switch. The rewind switch has now been checked. If the rewind system still does not function, see Section 7.5 Checking the Rewind Motor. ghi_tx000982gb.fm 76

77 7.5 Checking the Rewind Motor Rewind System Prerequisites Power components check OK Rewind switch check OK Procedure Follow the procedure below to check the rewind motor. 1. Start this test with circuit breaker 1 in the OFF position. 2. Locate the rewind motor (a). Note: Graphic for reference only, your machine may differ from that shown. This procedure continues on the next page. ghi_tx000982gb.fm 77

78 Rewind System Continued from the previous page. WARNING Electric shock hazard. High voltage exists inside the rewind motor. High voltage can cause severe injury or death. Use extreme care when working inside the rewind motor. 3. Remove the cover (b) of the rewind motor. 4. Disconnect white wire Place circuit breaker 1 in the ON position. 6. Place the rewind switch in the ON position. 7. Measure the voltage between black wire 6 and N1 of the main terminal strip. Is VAC measured? Continue. The wiring between the rewind switch and the rewind motor has failed. Disconnect the power supplies and repair the wiring. 8. Measure the voltage between black wire 6 and white wire 2. Is VAC measured? The rewind motor has failed. Disconnect the power sources and replace the rewind motor. White wire 2 has failed. Disconnect the power supplies and repair white wire 2. The rewind motor has now been checked. If the rewind system still does not function, see Section 7.6 Checking the Rewind Clutch (Solenoid). Re-assemble the machine. ghi_tx000982gb.fm 78

79 Rewind System 7.6 Checking the Rewind Clutch (Solenoid) Prerequisites Power components check OK Fuse 1 checks OK Procedure Follow the procedure below to check the rewind clutch (solenoid). 1. Open the control panel. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 2. Place circuit breaker 1 in the ON position. 3. Step on (or close) the foot switch and measure the DC voltage between terminals 5 and 6. Is VDC measured? Continue. Check the wiring to and function of the following components: rewind transformer; see Section 7.7/7.8 Checking the Rewind Transformer. rectifier; see Section 7.9/7.10 Checking the Rectifier. foot switch; see Section 7.11 Checking the Foot Switch. 4. Measure the resistance across terminal 5 and terminal 6. Is ohms measured? The rewind clutch solenoid is OK. The rewind clutch solenoid has failed; replace it. The rewind clutch solenoid has now been checked. If the rewind system still does not function, see Section 7.12 Checking the Rewind System Mechanical Components. ghi_tx000982gb.fm 79

80 Rewind System 7.7 Checking the Rewind Transformer (SN 1538 and higher) Prerequisites Power components check OK Fuse 1 checks OK Procedure Follow the procedure below to check the rewind transformer. 1. Start this test with circuit breaker 1 in the OFF position. 2. Open the control panel and locate the rewind transformer (a). 3. Disconnect both black wires 15 from the transformer. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 4. Place circuit breaker 1 in the ON position. 5. Measure the voltage between each black wire 15 and L2 (neutral) of the terminal strip. Is VAC measured? Continue. The wiring between fuse 1 and the rewind transformer has failed. Disconnect the power supply and repair the wiring. 6. Place circuit breaker 1 in the OFF position. 7. Reconnect both black wires 15. This procedure continues on the next page. ghi_tx000982gb.fm 80

81 Rewind System Continued from the previous page. 8. Measure the voltage between terminal 18 and fuse 2 (wire 20) of the terminal strip. Is VAC measured? The rewind transformer is OK. The rewind transformer has failed. Disconnect the power supply and replace the rewind transformer. The rewind transformer has now been checked. If the rewind system still does not function, see Section 7.9 Checking the Rectifier. ghi_tx000982gb.fm 81

82 Rewind System 7.8 Checking the Rewind Transformer (SN 1537 and lower) Prerequisites Power components check OK Fuse 1 checks OK Procedure Follow the procedure below to check the rewind transformer. 1. Start this test with circuit breaker 1 in the OFF position. 2. Open the control panel and locate the rewind transformer (a). 3. Disconnect both black wires 15 from the transformer. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 4. Place circuit breaker 1 in the ON position. 5. Place the rewind switch in the ON position. 6. Measure the voltage between each black wire 15 and L2 (neutral) of the terminal strip. Is VAC measured? Continue. The wiring between the rewind switch and the rewind transformer has failed. Disconnect the power supplies and repair the wiring. 7. Place circuit breaker 1 in the OFF position. 8. Reconnect both black wires Place circuit breaker 1 in the ON position. This procedure continues on the next page. ghi_tx000982gb.fm 82

83 Rewind System Continued from the previous page. 10.Measure the voltage between terminal 7 (wire 19) and terminal 12 (wire 18) of the rewind transformer Is VAC measured? The rewind transformer is OK. The rewind transformer has failed. Disconnect the power supply and replace the rewind transformer. The rewind transformer has now been checked. If the rewind system still does not function, see Section 7.10 Checking the Rectifier. Re-assemble the machine. ghi_tx000982gb.fm 83

84 Rewind System 7.9 Checking the Rectifier (SN 1538 and higher) Prerequisites Power components check OK Rewind transformer checks OK Fuse 2 checks OK Procedure Follow the procedure below to check the rectifier. 1. Start this test with circuit breaker 1 in the OFF position. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 2. Open the control panel and locate the rectifier (a). 3. Place circuit breaker 1 in the ON position. 4. Measure the AC voltage between terminal 19 and terminal 18 of the terminal strip. Is VAC measured? Continue. The wiring between the rewind transformer and the terminal strip has failed. Disconnect the power supplies and repair the wiring. 5. Measure the DC voltage between terminal 4 and terminal 6 of the terminal strip. Is VDC measured? The rectifier is OK. Check the wiring between the rectifier and the terminal strip. If the wiring is OK, the rectifier has failed. Disconnect the power supply and replace the rectifier The rectifier has now been checked. If the rewind system still does not function, see Section 7.11 Checking the Foot Switch. ghi_tx000982gb.fm 84

85 Rewind System 7.10 Checking the Rectifier (SN 1537 and lower) Prerequisites Power components check OK Rewind transformer checks OK Fuse 2 checks OK Procedure Follow the procedure below to check the rectifier. 1. Start this test with circuit breaker 1 in the OFF position. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 2. Open the control panel and locate the rectifier (a). 3. Place circuit breaker 1 in the ON position. 4. Make sure the wiring to the rectifier is connected tightly. 5. Measure the DC voltage between fuse 2 (wire 20) and terminal 6 of the terminal strip. Is VDC measured? The rectifier is OK. The rectifier has failed. Disconnect the power supply and replace the rectifier The rectifier has now been checked. If the rewind system still does not function, see Section 7.11 Checking the Foot Switch. ghi_tx000982gb.fm 85

86 Rewind System 7.11 Checking the Foot Switch Prerequisites Power components check OK Rectifier checks OK Procedure Follow the procedure below to check the foot switch. 1. Start this test with circuit breaker 1 in the OFF position. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 2. Open the control panel. 3. Step on (or close) the foot switch. 4. Measure the resistance between terminal 4 and terminal 5 of the terminal strip while stepping on the foot switch. Is approximately 0.1 ohms measured? Continue. The wiring (between the foot switch and the terminal strip) or the foot switch has failed. Disconnect the power supplies and repair the wiring or replace the foot switch. 5. Measure the resistance between terminal 4 and terminal 5 of the terminal strip while not stepping on the foot switch. Does your meter read OPEN or OL? Continue. ghi_gr The foot switch has failed. Disconnect the power supplies and replace the foot switch. This procedure continues on the next page. ghi_tx000982gb.fm 86

87 Rewind System Continued from the previous page. 6. Place circuit breaker 1 in the ON position. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 7. Measure the DC voltage between terminal 4 and 5 of the terminal strip while stepping on the foot switch. Is VDC measured? The foot switch is OK. ghi_gr The foot switch has failed. Disconnect the power supplies and replace the foot switch. The foot switch has now been checked. If the rewind system still does not function, see Section 7.12 Checking the Rewind System Mechanical Components. ghi_tx000982gb.fm 87

88 Rewind System 7.12 Checking the Rewind System Mechanical Components Prerequisites Power supplies disconnected Machine cool Procedure Follow the procedure below to check the rewind system mechanical components. WARNING Pinching/crushing hazard. Moving parts of the rewind system can pinch or crush. Disconnect the power supplies before checking the mechanical components. 1. Remove the chain guard (a) or side panels to access the system. 2. Inspect all the mechanical components: chain, gears, keys, bearings, etc. 3. Replace all damaged or missing components. ghi_tx000982gb.fm 88

89 8 Miscellaneous Components 8.1 Checking the Duplex Receptacle Miscellaneous Components Prerequisites Power components check OK Heating system fundamental components and K1 relay check OK Procedure Follow the procedure below to check the duplex receptacle. 1. Place circuit breaker 1 in the ON position. 2. Place the burner switch in the ON position. WARNING Electric shock hazard. High voltage exists at the duplex receptacle. High voltage can cause severe injury or death. Use extreme care when measuring voltage. 3. Measure the voltage at the duplex receptacle. Is VAC measured? The duplex receptacle is OK. Continue. This procedure continues on the next page. ghi_tx000983gb.fm 89

90 Miscellaneous Components Continued from the previous page. 4. Remove the cover of the duplex receptacle. WARNING Electric shock hazard. High voltage exists at the duplex receptacle. High voltage can cause severe injury or death. Use extreme care when measuring voltage. 5. Check the connections and continuity of neutral wire 2 from the duplex receptacle to L2 (neutral) of the terminal strip. Is there continuity ( ohms)? Continue. Repair neutral wire Measure the voltage between hot wire 8 and the neutral side of the duplex receptacle. Is VAC measured? The duplex receptacle has failed. Disconnect the power supplies and replace the duplex receptacle. Check the connections and continuity of wire 8 from the duplex receptacle back to relay 1. The duplex receptacle has now been checked. Re-assemble the machine. ghi_tx000983gb.fm 90

91 Miscellaneous Components 8.2 Checking an Indicator Light Prerequisites Power components check OK Heating system checks OK Procedure Follow the procedure below to check an indicator light (low level fault or burner fault lights). 1. Start this test with circuit breaker 1 in the OFF position. 2. Simulate a burner fault by removing the cad cell from burner. See Section 5.7 Checking the Primary Control. 3. Simulate a low level fault by disconnecting the probe from the low-level shutdown device. See Section 5.3 Checking the Low-Level Shut-Down Device. WARNING Electric shock hazard. High voltage exists inside the control panel. High voltage can cause severe injury or death. Use extreme care when working inside the control panel. 4. Open the control panel. 5. Locate the indicator light to be tested. 6. Place circuit breaker 1 in the ON position. 7. Place the burner switch in the ON position. Do the indicator lights illuminate? The indicator lights are OK. Continue. 8. Measure the voltage between the incoming side (black wire 17 or 23) of the indicator light and L2 (neutral) of the terminal strip. Is VAC measured? Continue. The wiring to the indicator light has failed. Disconnect the power supplies and repair the wiring. 9. Check the resistance (continuity) of the white wire from the indicator light back to the terminal strip. Does the white wire have continuity? The indicator light has failed. Disconnect the power supplies and replace the indicator light. The white wire has failed. Disconnect the power supplies and repair the wiring. The indicator light has now been checked. Re-assemble the machine. ghi_tx000983gb.fm 91

92 Miscellaneous Components 8.3 Checking the Fuel Prewarmer Prerequisites Power components check OK Heating system fundamental components check OK Procedure Follow the procedure below to check the fuel prewarmer. 1. Remove the primary control by loosening screws (c). 2. Loosen tabs (b) and hinge back the igniter plate cover. 3. Disconnect the fuel prewarmer. 4. Measure the resistance of the fuel prewarmer at the connector (d). Is ohms measured? Continue. The fuel prewarmer has failed. Disconnect the power supplies and replace the prewarmer. This procedure continues on the next page. ghi_tx000983gb.fm 92

93 Miscellaneous Components Continued from the previous page. 5. Place circuit breaker 1 in the ON position. WARNING Electric shock hazard. High voltage exists on the fuel prewarmer when the burner switch is in the ON position. High voltage can cause severe injury or death. Use extreme care when working on the prewarmer. 6. Place the burner switch in the ON position. 7. Measure the voltage between the two wires of the connector (e). Is VAC measured? The fuel prewarmer is OK. The wiring to the fuel prewarmer has failed. Disconnect the power supplies and replace the wiring. The procedure to check the fuel prewarmer is now complete. ghi_tx000983gb.fm 93

94 Burner Setup 9 Burner Setup Factory settings Head Firing rate L/hr (gph) Nozzle size Fuel pressure bar (psi) Air band setting Air shutter L1 3.4 (0.90) A 12.4 (180) 2 4 F3 3.4 (0.90) A 10.0 (145) 2 4 Background The burner consists of several different components and subsystems. Each of these components or subsystems must be operating correctly for the burner to function properly. Fuel Low ambient temperatures cause diesel fuels to gel. Gelled fuels will cause burner ignition failure and/or burner fuel pump damage. Always use the proper fuel for the conditions. Lowest expected ambient temperature F ( C) Below 5 (-15) 5 to 25 (-15 to -4) Above 25 (-4) Fuel Blend Guide Generator powered blend of #2 diesel and #1 diesel, plus additives OR blend #2 diesel and K1 kerosene, plus additives Shore powered 100% #1 diesel plus additives OR 100% K1 kerosene, plus additives blend of #2 diesel and #1 diesel, plus additives OR blend of #2 diesel and K1 kerosene, plus additives Winter-blend diesel Tools required The following tools are required to adjust the burner: High-quality combustion analyzer Smoke spot tester Fuel pressure test gauge General hand tools Mandates Adjustments made shall be done so that the machine conforms to the requirements of local, state, and federal codes and authorities. Adjustments shall be made at the job site. This procedure continues on the next page. ghi_tx001172gb.fm 94

95 Continued from the previous page. Burner Setup When Procedure Adjust the burner: Before operating the machine at elevations 305 m (1,000 ft) above or below the location of where the last adjustments were made. Before starting at a new job site. After any burner maintenance or repair has been performed. If burner performance is in question. Follow the procedures below to set up the burner. 1. Shut down the machine. 2. Set the burner electrodes. (See Section 9.2 Setting/Checking the Electrodes on page 99.) 3. Check the burner nozzle. (See Section 9.3 Checking/Replacing the Nozzle on page 101.) 4. Check/set the Z distance. (See Section 9.4 Setting the Z Distance ( L head) on page 104.) or (See Section 9.5 Setting the Z Distance ( F head) on page 105.) 5. Set the air settings. (See Section 9.6 Adjusting the Air Settings on page 107.) 6. Start the machine and the burner. 7. Check/set the fuel pressure. (See Section 9.7 Setting the Fuel Pressure on page 108.) 8. Conduct a smoke spot test. Follow the smoke spot tester manufacturer s instructions and the general guidelines below. Use the access hole in the exhaust stack. Several samples should be taken as the heater warms. The final sample should be taken just before the heater reaches 71 C (160 F). This procedure continues on the next page. ghi_tx001172gb.fm 95

96 Burner Setup Continued from the previous page. 9. Analyze the combustion. Follow the combustion analyzer manufacturer s instructions and the general guidelines below. Use the access hole in the exhaust stack. Take several samples as the heater warms. Take the final sample just before the heater reaches 71 C (160 F). 10.Re-adjust the air setting(s) if necessary until the smoke spot test and combustion analysis are within the following parameters: O 2 content: 4 6% Smoke spot: 1 or less Result You have now setup the burner. ghi_tx001172gb.fm 96

97 9.1 Determining the Burner Head Type Burner Setup Prerequisites Power supplies disconnected from the machine Machine cool Procedure Follow the procedure below to determine the burner head type. 1. Disconnect the power supplies. 2. Remove the copper fuel line (a) between the fuel pump and the burner housing. Note: Only remove the fuel fitting closest to the burner housing. 3. Remove the knurl nut (b) that is seated against the escutcheon plate. NOTICE: Handle the knurled knob with care. It is easily damaged. 4. Loosen tabs (c) and hinge back the igniter cover.. 5. Disconnect the wiring to the electrode/nozzle assembly. 6. Maneuver the electrode/nozzle assembly (d) up and out of the burner. This procedure continues on the next page. ghi_tx001172gb.fm 97

98 Burner Setup Continued from the previous page. 7. Determine which type of head your burner has. If the electrode/nozzle assembly looks like (L), the head is an L style. If the electrode/nozzle assembly looks like (F), the head is an F style. Result You have now determined the burner type. ghi_tx001172gb.fm 98

99 9.2 Setting/Checking the Electrodes Burner Setup Prerequisites Power supplies disconnected Measuring device Procedure Follow the procedure below to check the electrodes. Note: Procedure shows the F head. 1. Disconnect the power supplies. 2. Remove the copper fuel line (a) between the fuel pump and the burner housing. Note: Only remove the fuel fitting closest to the burner housing. 3. Remove the knurl nut (b) that is seated against the escutcheon plate. NOTICE: Handle the knurled knob with care. It is easily damaged. 4. Loosen tabs (c) and hinge back the igniter cover.. 5. Disconnect the wiring to the electrode assembly. 6. Maneuver the electrode assembly (d) up and out of the burner. This procedure continues on the next page. ghi_tx001172gb.fm 99

100 Burner Setup Continued from the previous page. 7. Use the measurements below to properly set the electrode tips on both the F and the L head. Note: Beckett also has special tools for measuring the Z distance: The Beckett Z gauge may be used on F heads. The Beckett T501 gauge may be used on both F and L heads. Ref. Description Gap distance h Electrode tip to electrode tip 5/32 in. (4 mm) i Nozzle center to electrode tip 5/16 in. (7.5 mm) j Nozzle end to electrode tip end 1/16 in. (1.5 mm) Result You have now checked/adjusted the electrodes. ghi_tx001172gb.fm 100

101 9.3 Checking/Replacing the Nozzle Burner Setup Prerequisites Power supplies disconnected Machine cool Removal Follow the procedure below to remove the burner nozzle. 1. Disconnect the power supplies. 2. Remove the copper fuel line (a) between the fuel pump and the burner housing. 3. Remove the knurl nut (b) that is seated against the escutcheon plate. Note: Handle the knurled knob with care. It is easily damaged. 4. Loosen tabs (c) and hinge back the igniter cover.. 5. Disconnect the preheater wiring. 6. Maneuver the electrode assembly (d) up and out of the burner. This procedure continues on the next page. ghi_tx001172gb.fm 101

102 Burner Setup Continued from the previous page. 7. Unscrew the burner nozzle from the burner tube. The procedure to remove the burner nozzle is now complete. Installation Follow the procedure below to install the burner nozzle. 1. Thread the new burner nozzle into the burner tube. Note: Do not use thread sealant on the threads. 2. Position the igniter assembly (d) into the burner. 3. Connect the preheater wiring. 4. Close the igniter cover and secure it with tabs (c). This procedure continues on the next page. ghi_tx001172gb.fm 102

103 Continued from the previous page. 5. Install the knurl nut (b) that is seated against the escutcheon plate. Note: Handle the knurled knob with care. It is easily damaged. Burner Setup 6. Install the copper fuel line (a) between the fuel pump and the burner housing. Result You have now replaced the nozzle. ghi_tx001172gb.fm 103

104 Burner Setup 9.4 Setting the Z Distance ( L head) Prerequisites Burner removed from the machine T501 gauge Procedure Follow the procedure below to set the Z distance on L heads. 1. Remove the burner from the machine. 2. Loosen the knurled nut (b). 3. Loosen the hex head screw (e). 4. Butt-up the T501 gauge or a ruler to the leading edge of the head (d). 5. Slide the head in or out as needed so that the C mark (c) of the T501 gauge aligns with the outside edge of the conical-shaped shroud. Or, adjust the distance from the leading edge of the head to the outside edge of the conicalshaped shroud to be 44.5 mm (1-3/4 in.). 6. Tighten the hex screw (e). 7. Tighten the knurled nut (b). 8. Mark (x) the escutcheon plate for later reference. x Result You have now set the Z distance. ghi_tx001172gb.fm 104

105 9.5 Setting the Z Distance ( F head) Burner Setup Prerequisites Burner removed from the machine T501 gauge or Z gauge Procedure Follow the procedure below to set the Z distance on F-style heads. 1. Remove the burner from the machine. 2. Loosen the knurled nut (b). 3. Loosen the position locking screw (e). 4. Set the Z distance by using one of the three following methods: using Beckett T501 gauge, by measuring, or using Beckett Z gauge. Beckett T501 gauge Using the Beckett T501 gauge. a. Position the gauge into the flame retention head as shown. b. Slide the nozzle assembly so that the front face of the burner nozzle touches the T501 gauge. c. Tighten the position locking screw. d. Tighten the knurled nut. e. Mark the escutcheon plate for later reference. See step 5. This procedure continues on the next page. ghi_tx001172gb.fm 105

106 Burner Setup Measuring Continued from the previous page. Measuring the Z distance. a. Place a straight edge over the end of the flame retention head. b. Adjust the nozzle assembly until the distance between the front face of the burner nozzle and the end of the head measures 1-1/8 inches (28 mm). c. Tighten the position locking screw (e). d. Tighten the knurled nut. f. Mark the escutcheon plate for later reference. See step 5. Beckett Z gauge The Beckett Z gauge may also be used. Refer to the Beckett instructions for detailed information. x 5. Mark (x) the escutcheon plate for later reference. Result You have now set the Z distance. ghi_tx001172gb.fm 106

107 Burner Setup 9.6 Adjusting the Air Settings Factory settings Air band: 2 Air shutter: 4 These settings are initial settings only. Adjust the air settings as necessary to obtain the proper smoke spot and combustion analysis values. Background There are two parts to the adjusting the air setting: 1) air band; and 2) air shutter. Adjust the air band to make large adjustments. Adjust the air shutter to make small adjustments. Affects The air setting has the following effect on combustion. Higher O 2 percentage (excess air settings) lowers soot production but raises stack temperature and reduces efficiency: lean mixture. Lower O 2 percentage (inadequate air settings) increases efficiency and lowers stack temperature but may cause soot build-up: rich mixture. Procedure Follow the procedure below to adjust the air settings. 1. Initial setting of the air damper should be performed with the machine shut down. 2. Loosen the air band locking screw (a) and the air shutter locking screw (b). 3. Using the band position pointer (c) to determine position, move the air band to a higher number to increase air volume. Turn it to a lower number to decrease air volume. 4. Using the shutter position pointer (d) to determine position, move the air shutter to a higher number on the shutter position pointer to increase air volume. Turn it to a lower number to decrease air volume. 5. After the air settings have been made, tighten the band-locking screw (a) and the shutter-locking screw (b). Result You have now adjusted the air settings. ghi_tx001172gb.fm 107

108 Burner Setup 9.7 Setting the Fuel Pressure Factory setting Factory settings: F head: 145 psig (10.0 bar) L head: 180 psig (12.4 bar) Procedure Follow the procedure below to check and adjust the fuel pressure. 1. Shut down the machine. 2. Remove the bleeder valve (a) from the fuel pump. 3. Insert the gauge in place of the bleeder valve. 4. If your machine has a generator, start it. 5. Turn the control switch to HEAT. The burner will go through a pre-purge cycle. Monitor and make adjustments during the pre-purge cycle. 6. Turn the adjusting screw (b) clockwise to increase fuel pressure, counterclockwise to decrease fuel pressure. Result You have now adjusted the fuel pressure. ghi_tx001172gb.fm 108

109 10 Disassembly and Assembly Disassembly and Assembly 10.1 Tools Required for Disassembly/Assembly Procedures It is up to the mechanic to use common sense and good judgment in tool selection to reduce the risk of injury while repairing the machine. In cases where a special tool is required, the special tool is listed in the prerequisite section of the procedure. Before substituting another tool or procedure from those recommended in this manual, the mechanic must be satisfied that neither personal injury nor damage to the machine will result due to the substitution Information Regarding Replacement Parts The repair procedures contained in this manual do not include part numbers. For replacement parts information, refer to the Parts Book originally supplied with the machine. If the original Parts Book has been lost, a replacement may be ordered from Wacker Neuson Corporation. When ordering a replacement Parts Book, please list the model number, item number, revision level, and serial number of the machine. Parts Books are also available on the Wacker Neuson Corporation Web site. See Enter the site as a visitor Information Regarding Reference Numbers Repair procedures contain reference numbers enclosed in parentheses ( ). These numbers refer to the item numbers shown on the assembly drawings and other detailed drawings. They are included to aid the mechanic in identifying parts and assembling components. ghi_tx000984gb.fm 109

110 Disassembly and Assembly 10.4 Removing the Burner Prerequisites Power supplies disconnected Machine cool Procedure Follow the procedure below to remove the burner. 1. Disconnect the power supplies. 2. Disconnect fuel lines (a) at the quick-connects. 3. Remove the primary control (b) to expose the wiring. Label all the wires to assist in reconnecting. 4. Disconnect all wires coming from the snap switch cable (c). Note: The snap switch cable is a large black insulated wire that enters the electrical enclosure from the rear. 5. Disconnect all wires coming from the burner cable (d). Note: The burner cable is a large black insulated wire that enters the electrical enclosure from the left side. 6. Remove the screws that secure the burner to the machine and maneuver the burner from the machine. The procedure to remove the burner is now complete. ghi_tx000984gb.fm 110

111 Disassembly and Assembly 10.5 Installing the Burner Prerequisites Power supplies disconnected Machine cool Procedure Follow the procedure below to install the burner. 1. Position the burner inside the machine and secure it to the hydronic heater. 2. Connect fuel lines (a) at the quick-connects. 3. Install the primary control (b). 4. Connect all wires coming from the burner cable (d). 5. Connect all wires coming from the snap switch cable (c). The procedure to install the burner is now complete. ghi_tx000984gb.fm 111

112 Disassembly and Assembly 10.6 Replacing the Fuel Pump Prerequisites Machine shut down Burner removed from machine Removal Follow the procedure below to remove the fuel pump. 1. Remove the solenoid power cord (a). 2. Remove the copper fuel line (b). 3. Remove the pump mounting screws (c). Save them for later use. 4. Pull the pump away from the burner housing. This exposes the drive coupling (d). Save the drive coupling for later use. This procedure continues on the next page. ghi_tx000984gb.fm 112

113 Continued from the previous page. Disassembly and Assembly 5. Remove both fuel line assemblies and hose barbs (e) from the fuel pump. Save them for later use. 6. Remove the bypass plug (set screw) from the return port (f). Save it for later use. The procedure to remove the fuel pump is now complete. Installation Follow the procedure below to install the fuel pump. 1. Install the bypass plug (set screw) into the return port (f). NOTICE: To avoid damage to the fuel pump, the bypass plug must be installed. Re-use the bypass plug from the old fuel pump or use the bypass plug shipped with the new fuel pump. 2. Apply thread sealant to the hose barbs (e) and install the fuel line assemblies into the proper ports. Note: Install the fuel line with the attached fuel filter into the SUPPLY port. 3. Mount the new pump onto the burner housing. Take care to align the new pump shaft into the drive coupling. This procedure continues on the next page. ghi_tx000984gb.fm 113

114 Disassembly and Assembly Continued from the previous page. 4. Use the old screws (c) to secure the pump to the burner housing. 5. Reconnect the copper fuel line (b) onto the new pump. 6. Reconnect the existing solenoid power cord (a) onto the new pump. The procedure to replace the fuel pump is now complete. ghi_tx000984gb.fm 114

115 10.7 Replacing the Burner Fan Motor Disassembly and Assembly Prerequisites Machine shut down Burner removed from machine Removal Follow the procedure below to remove the burner fan motor. 1. Remove the primary control by loosening screws (c). INTRPT/IGNITER BURNER/MOTOR L1 L2 L2 L2 L2 CAD CELL 2 LIMIT VALVE 2. Locate and remove the orange wire and white wire that power the burner fan motor from the primary control. 3. Pull the orange wire and white wire from the junction box. 4. Remove the burner fan motor assembly from the burner housing. Note: Be careful not to pull out the fuel pump coupling when removing the burner fan motor. This procedure continues on the next page. ghi_tx000984gb.fm 115

116 Disassembly and Assembly Continued from the previous page. 5. Loosen the set screw and remove the fan (a). Save the fan for reuse. The procedure to remove the burner fan motor is now complete. Installation Follow the procedure below to install the burner fan motor. 1. Install the fan (a) onto the burner fan motor shaft (tighten the set screw onto the flat of the shaft). 2. Install the burner fan motor assembly (b) to the burner housing. 3. Route the orange wire and the white wire into the junction box. 4. Connect the orange wire to the BURNER MOTOR terminal of the primary control. 5. Connect the white wire to the L2 terminal of the primary control. 6. Reconnect the primary control. The procedure to install the burner fan motor is now complete. ghi_tx000984gb.fm 116

117 10.8 Replacing an HTF Pump Disassembly and Assembly Prerequisites Power supplies disconnected Machine cool Container to collect spilled HTF Removal Follow the procedure below to remove the HTF pump. 1. Disconnect the power supplies. 2. Remove the stack (a) and the side panel (b) and locate the HTF pump assembly (j). b a 3. Disconnect the hose from the hose reel (c). 4. Place the two-position valve (d) in the SERVICE position. This procedure continues on the next page. ghi_tx000984gb.fm 117

118 Disassembly and Assembly Continued from the previous page. 5. Place a container inside the machine to catch any spilled HTF. When finished, dispose of the HTF according to local environmental regulations. 6. Remove and cap the hose (e) from the upper fitting of the HTF pump. 7. Remove and cap the hose (f) from the lower fitting of the HTF pump. 8. Clip the wire tie (g). 9. Loosen the hose clamp and remove the small hose (h). This procedure continues on the next page. ghi_tx000984gb.fm 118

119 Continued from the previous page. Disassembly and Assembly 10.Remove the three screws that secure the HTF pump (i) to the motor adapter and remove the HTF pump. 11.Remove the pipe fittings and the Lovejoy coupling (k) from the HTF pump. Save these components for reuse. The procedure to remove the HTF pump is now complete. Installation Follow the procedure below to install the HTF pump. 1. Inspect and clean the pipe fittings. Apply sealant to the threads and re-install them to the HTF pump (l). 2. Place the old Lovejoy coupling (e) onto the shaft of the new HTF pump. Align the set screw with the flat of the HTF pump shaft. Screw in the set screw only enough to hold the alignment with the flat. Do not tighten the set screw yet. This procedure continues on the next page. ghi_tx000984gb.fm 119

120 Disassembly and Assembly Continued from the previous page. 3. Place the flexible portion of the Lovejoy coupling (n) onto the shaft of the pump motor. For clarity, the pump motor is shown without the motor adapter. 4. Align the two halves of the Lovejoy coupling and install the new HTF pump onto the motor adapter (m). 5. Access the Lovejoy coupling through the slot in the motor adapter. Slide the two halves of the Lovejoy coupling together and tighten the set screw (o). 6. Reconnect the small hose (h). 7. Reconnect the hose (f) to the lower fitting of the HTF pump. 8. Reconnect the hose (e) to the upper fitting of the HTF pump. This procedure continues on the next page. ghi_tx000984gb.fm 120

121 Continued from the previous page. 9. Secure the wiring harness with a new wire tie. 10.Reconnect the hose to the hose reel (c). Disassembly and Assembly 11.Place the two-position valve (d) in the NORMAL position. 12.Re-install the side panel and stack. 13.Clean the HTF filter. See Section 9.12 Changing an HTF Filter. Run the HTF pump for a few minutes, then shut down the pump and check the HTF filter again. Repeat as necessary until the HTF flows free of any dirt or particulates. The procedure to replace the HTF pump is now complete. ghi_tx000984gb.fm 121

122 Disassembly and Assembly 10.9 Replacing the HTF Pump Motor Prerequisites Power supplies disconnected Machine cool Removal Follow the procedure below to remove the HTF pump. 1. Disconnect the power supplies. 2. Remove the stack (a) and the side panel (b) and locate the HTF pump assembly (j). b a 3. Cut the wire tie that secures the wiring harness to the fittings of the HTF pump. 4. Remove the three screws that secure the HTF pump (c) to the motor flange and remove HTF pump/hoses from the motor flange. c ghi_gr Remove the cover from the junction box (d). This procedure continues on the next page. ghi_tx000984gb.fm 122

123 Continued from the previous page. Disassembly and Assembly 6. Disconnect the white, black, and green wires from the motor. 7. Pull the wiring (e) from the control box. 8. Remove the screws and nuts that secure the HTF pump motor to the machine. Pull the HTF pump motor (f) from the machine. 9. Remove the motor adapter (g) and the Lovejoy coupling (h). Save both components for re-use. The procedure to remove the HTF pump motor is now complete. This procedure continues on the next page. ghi_tx000984gb.fm 123

124 Disassembly and Assembly Installation Continued from the previous page. Follow the procedure below to install the HTF pump motor. 1. Install the Lovejoy coupling to the shaft of the HTF pump motor. Align the coupling so that the main hub is flush with the end of the shaft. Install the flexible portion of the Lovejoy coupling. 2. Install the motor adapter (g). 3. Place the HTF pump assembly into the machine and secure it with the screws and nuts. 4. Insert the wiring into the junction box and reconnect it. 5. Re-install the cover of the junction box. 6. Secure the wiring harness with a new wire tie. 7. Secure the HTF pump (c) to the motor flange. 8. Re-install the side panel and stack. The procedure to replace the HTF pump motor is now complete. ghi_tx000984gb.fm 124

125 Disassembly and Assembly Changing a Turbulator/Cleaning a Turbulator Tube Prerequisites Machine shut down Machine cool Procedure Follow the procedure below to clean/change the turbulator tubes. 1. Allow the machine to cool. WARNING Burn hazard. The hydronic heater is very hot when the machine is operating. When hot it can cause severe burns. Allow the machine to cool before performing this procedure. 2. Remove the nuts (a) that secure the flue box door. 3. Open the flue box door (b). NOTICE: If the door panel insulation does not open with the door, carefully remove it from where it is caught on the bolts (c). 4. Locate the turbulators housed in the burner tubes. 5. Remove the turbulators (d) by pulling the turbulator tab. Replace any turbulator that is badly corroded. 6. Clean each burner tube with a bottle brush. 7. Vacuum out each burner tube. The procedure is now complete. Re-assemble the machine. ghi_tx000984gb.fm 125

126 Disassembly and Assembly Repairing a Hose Prerequisites Hose nipple Two hose ferrules Hose crimping tool part number Procedure Follow the procedure below to repair a damaged hose. 1. Shut down the machine and allow the Heat Transfer Fluid (HTF) to cool. 2. Locate the damaged portion of the hose and clamp locking pliers on either side of the damaged portion. 3. Cut away the damaged portion of the hose (a) using a utility knife or similar tool. 4. Install a ferrule (b) on either end of the freshly cut hose. 5. Install the nipple (c) into one of the hoses. NOTICE: Do not use petroleum to lubricate the nipple. If lubrication is needed, use HTF. 6. Install the nipple into the second hose with ferrule. Be sure to push each end of each hose to the lip of the nipple. This procedure continues on the next page. ghi_tx000984gb.fm 126

127 Continued from the previous page. Disassembly and Assembly 7. Use a Wacker Neuson brand hose crimper (e) to crimp both ferrules. The procedure is now complete. ghi_tx000984gb.fm 127

128 Disassembly and Assembly Changing a HTF Filter Prerequisites Machine shut down Machine cool Removal Follow the procedure below to remove the HTF filter. 1. Shut down the machine and allow the (Heat Transfer Fluid) HTF to cool. 2. Locate the filter assembly (a). a ghi_gr Note: HTF may spill when changing the filter. Do not allow the HTF to spill on the ground. Clean up spilled HTF immediately. Dispose of the HTF and soiled rags in accordance with local environmental regulations. 3. Remove the bolt (c) from the top of the filter head (d) and separate the filter head from the bowl (e). 4. Remove and inspect the filter (f) and the gaskets (g). Discard a damaged filter or gaskets. 5. If reusing the filter or gaskets, wash them thoroughly with tap water. The procedure to remove the filter is now complete. Installation Follow the procedure below to install the HTF filter. This procedure continues on the next page. ghi_tx000984gb.fm 128

129 Continued from the previous page. 1. Install gaskets (g) to the filter (f). Disassembly and Assembly 2. Place the filter and gaskets into the bowl (e). 3. Install the assembly using bolt (c). The procedure to change the HTF filter is now complete. ghi_tx000984gb.fm 129

130 Disassembly and Assembly Changing the Low-Level Probe Prerequisites Machine shut down Heat Transfer Fluid (HTF) drained Removal Follow the procedure below to remove the low-level probe. 1. Drain the HTF from the machine. See the Operator s Manual. 2. Remove the stack (a) and the side panel (b). 3. Locate the low-level probe (c). 4. Disconnect the wiring from the probe. 5. Remove the low-level probe by unscrewing it from the hydronic heater. The procedure to remove the low-level probe is now complete. Installation Follow the procedure below to install the low-level probe. 1. Apply thread sealant to all but the first three threads of the low-level probe. 2. Screw the low-level probe into the hydronic heater. 3. Reconnect the wiring to the low-level probe. 4. Re-install the side panel and the stack. 5. Refill the machine with HTF. See the Operator s Manual. The procedure to replace the low-level probe is now complete. ghi_tx000984gb.fm 130

131 10.14 Replacing the Thermocouple Disassembly and Assembly Prerequisites Machine shut down Machine cool Removal Follow the procedure below to remove the thermocouple. 1. Remove the canister lid (a) from the thermocouple body. 2. Loosen the strain relief (b). 3. Disconnect the wiring (c). 4. Unscrew the thermocouple (d) from the well in the hydronic heater. The procedure to remove the thermocouple is now complete. Installation Follow the procedure below to install the thermocouple. 1. Screw the thermocouple (d) into the well of the hydronic heater. 2. Thread the wiring (c) through the strain relief and connect it to the thermocouple. 3. Tighten the strain relief (b). 4. Install the canister lid (a). The procedure to replace the thermocouple is now complete. ghi_tx000984gb.fm 131

Repair Manual Indirect-Fired Air Heater Cub 200 Cub 300

Repair Manual Indirect-Fired Air Heater Cub 200 Cub 300 Repair Manual Indirect-Fired Air Heater Cub 200 Cub 300 0179422en 001 1009 0 1 7 9 4 2 2 E N Copyright notice Copyright 2009 by Wacker Neuson Corporation. All rights, including copying and distribution

More information

Operator s Manual. Hydronic Air Heater. Arctic Bear XHD-NS en /

Operator s Manual. Hydronic Air Heater. Arctic Bear XHD-NS en / Operator s Manual Hydronic Air Heater Arctic Bear XHD-NS 0 1 7 8 3 9 1 E N 0178391en / 001 1107 Arctic Bear XHD Foreword Foreword Machines covered by this manual This manual covers machines with the following

More information

HI 110D / HI 110HD D HI 200D / HI 200HD D HI 300D / HI 300HD D

HI 110D / HI 110HD D HI 200D / HI 200HD D HI 300D / HI 300HD D Operator s Manual Indirect-Fired Air Heaters HI 110D / HI 110HD D HI 200D / HI 200HD D HI 300D / HI 300HD D EN 5000192822 03 1211 5 0 0 0 1 9 2 8 2 2 Copyright notice Copyright 2011 by Wacker Neuson Production

More information

HI 400 HD D HI 400 HD G

HI 400 HD D HI 400 HD G Operator s Manual Indirect-Fired Air Heaters HI 400 HD D HI 400 HD G EN 5000192824 03 1211 5 0 0 0 1 9 2 8 2 4 Copyright notice Copyright 2011 by Wacker Neuson Production Americas LLC All rights, including

More information

HI 110D / HI 110HD D HI 200D / HI 200HD D HI 300D / HI 300HD D

HI 110D / HI 110HD D HI 200D / HI 200HD D HI 300D / HI 300HD D Operator s Manual Indirect-Fired Air Heaters HI 110D / HI 110HD D HI 200D / HI 200HD D HI 300D / HI 300HD D 0192822 001 1110 0 1 9 2 8 2 2 Copyright notice Copyright 2010 by Wacker Neuson Corporation.

More information

Operator s Manual. Hydronic Surface Heater HSH 350

Operator s Manual. Hydronic Surface Heater HSH 350 Operator s Manual Hydronic Surface Heater HSH 350 5000186637 03 0311 5 0 0 0 1 8 6 6 3 7 Copyright notice Copyright 2011 by Wacker Neuson Production Americas LLC All rights, including copying and distribution

More information

en Indirect Lighting System LB 1 OPERATOR S MANUAL

en Indirect Lighting System LB 1 OPERATOR S MANUAL 0163721en 003 0708 Indirect Lighting System LB 1 OPERATOR S MANUAL 0 1 6 3 7 2 1 E N LB 1 Table of Contents Foreword 4 1 Safety Information 5 1.1 Callouts Found in this Manual... 5 1.2 Safety Guidelines

More information

Interrupted Ignition Series Oil Primary Control

Interrupted Ignition Series Oil Primary Control Interrupted Ignition Series Oil Primary Control Application Guide & Installation Instruction for ICM1511*, ICM1512*, ICM151*, ICM1514* For more information on our complete range of American-made products

More information

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

DF400/DF600. Construction Heaters. Installation and Maintenance Manual 342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. DF400/DF600 Construction

More information

en Generator CARB GP 2600 OPERATOR S MANUAL

en Generator CARB GP 2600 OPERATOR S MANUAL 0163125en 003 0609 Generator CARB GP 2600 OPERATOR S MANUAL 0 1 6 3 1 2 5 E N DANGER CARBON MONOXIDE Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide (CO).

More information

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit Packaged Gas/Electric Units Owner s Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK HAZARD. FIRE OR EXPLOSION HAZARD Disconnect power at fuse box or service panel before performing

More information

Operator s Manual. Light Balloon LB en

Operator s Manual. Light Balloon LB en Operator s Manual Light Balloon LB 1 0175081en 004 0410 0 1 7 5 0 8 1 E N Copyright notice Copyright 2010 by Wacker Neuson Corporation. All rights, including copying and distribution rights, are reserved.

More information

Model Universal Oil Primary Control

Model Universal Oil Primary Control Model 70200 Universal Oil Primary Control Installation and Operating Instructions For Use By Qualified Service Technicians Only Universal Replacement for Carlin, Beckett, Honeywell and ICM Controls On-Board

More information

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com Owner s Manual MGD-B SERIES GAS FURNACE

More information

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION INSTALLATION AND OPERATING INSTRUCTIONS FOR THE HARDY Fuel Oil Furnace Models D-140 & D-350 HARDY MANUFACTURING COMPANY, INC. 12345 ROAD 505 PHILADELPHIA, MS 39350 PHONE: (601) 656-5866 FAX: (601) 656-4559

More information

Operator s Manual. Portable Generator GP 6600A GPS 6600A

Operator s Manual. Portable Generator GP 6600A GPS 6600A Operator s Manual Portable Generator GP 6600A GPS 6600A EN 5000192975 01 0511 5 0 0 0 1 9 2 9 7 5 Copyright notice Copyright 2011 by Wacker Neuson Production Americas LLC All rights, including copying

More information

Operator s Manual. Floor Saw BFS 16 BFS 18 BFS 20

Operator s Manual. Floor Saw BFS 16 BFS 18 BFS 20 Operator s Manual Floor Saw BFS 16 BFS 18 BFS 20 5000405152 01 0412 5 0 0 0 4 0 5 1 5 2 Copyright notice Copyright 2012 by Wacker Neuson Corporation. All rights, including copying and distribution rights,

More information

Bosch 80% AFUE Gas Furnace BGS80 Model

Bosch 80% AFUE Gas Furnace BGS80 Model Bosch 80% AFUE Gas Furnace BGS80 Model 4-Way Multipoise Category I Fan-Assisted Furnace User's Information Manual 3124627 2 Bosch 80% AFUE Gas Furnace User's Information Manual Data subject to change 06.2018

More information

Direct Vent Supplement

Direct Vent Supplement Direct Vent Supplement UMLA / UMLVA Oil Fired Warm Air Furnaces INSTALLATION, OPERATION & MAINTENANCE MANUAL! WARNING Fire, explosion, asphyxiation and electrical shock hazard. Improper installation could

More information

en Direct oil-fired space heaters HD... Operator's manual

en Direct oil-fired space heaters HD... Operator's manual 0211670en 002 12.2007 Direct oil-fired space heaters HD... Operator's manual Table of contents 1. Foreword 5 2. Safety information 6 2.1 General recommendations... 6 2.2 Safety devices... 7 2.3 Labels...

More information

Fig. 1 - Unit PGD4, PGS4, WPG4

Fig. 1 - Unit PGD4, PGS4, WPG4 OWNER S MANUAL 14 SEER Single -Package Air Conditioner and Gas Furnace System with R -410A Refrigerant Single Phase 2 to 5 Nominal Tons Three Phase 3 to 5 Nominal Tons PGD4andPGS4SeriesE,WPG4SeriesB Fig.

More information

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator. Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N260.3 - a 2.4 cu. ft., 3-way refrigerator. NORCOLD, Inc. P.O. Box 4248 Sidney, OH 45365-4248 Part No. 619260A (4-98) Table

More information

- 12 VDC. HHE M - 12 VDC.

- 12 VDC. HHE M - 12 VDC. R OWNER S MANUAL Model Number HHE-200-09E - 12 VDC. HHE-500-09M - 12 VDC. OWNER S INFORMATION Owner s Name: Address: City: State: Zip Code: CUT HERE AND MAIL IN Telephone: E-mail Address: Motorhome Model:

More information

Model 60200FR Gas Primary Control Data Sheet

Model 60200FR Gas Primary Control Data Sheet Programmable, Microprocessor Based Gas Burner Primary Controls On-Board LCD Screen Easy to Understand Icons for Inputs and Outputs Displays micro-amp Flame reading Display operational information Fault

More information

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC ) Installation Manual For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC ) N404M.3 (128 liter 3-way operation with LP gas, 240 volts AC, or 12

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL : If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline

More information

HOME OWNER S INFORMATION Induced Combustion Gas Furnace

HOME OWNER S INFORMATION Induced Combustion Gas Furnace HOME OWNER S INFORMATION Induced Combustion Gas Furnace NOTE TO INSTALLER: This manual must be left with the equipment user. USER: Please read all instructions in the manual and retain all manuals for

More information

AHE S -12 VDC AHE S - 24 VDC

AHE S -12 VDC AHE S - 24 VDC Owner s Manual Model Numbers AHE-100-02S -12 VDC AHE-200-02S - 24 VDC OWNER S INFORMATION Owner s Name: Address: City: State: Zip Code: CUT HERE AND MAIL IN Telephone: Coach Model: Coach Date of Purchase:

More information

BGH Series Hot Surface Ignition Control

BGH Series Hot Surface Ignition Control Installation Instructions BGH Series Issue Date April 14, 2011 BGH Series Hot Surface Ignition Control Application The BASO Gas Products BGH Series Hot Surface Ignition (HSI) control is microprocessor

More information

Owner s Information Manual

Owner s Information Manual 48ES---A and 48VL---A Comfort and Performance 13 and 14 SEER Single Packaged Air Conditioner and Gas Furnace System With Puron (R---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60)

More information

USERS INFORMATION MANUAL

USERS INFORMATION MANUAL MODULAR DX OR CHILLED WATER COOLING WITH ELECTRIC OR HOT WATER HEATING MODELS: US, UM SERIES USERS INFORMATION MANUAL For Installation In: 1. Modular Homes & Buildings 2. Residential Homes LIST OF SECTIONS

More information

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER)

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER) 100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER) WARNING If the information in these instructions is not followed exactly, a

More information

Packaged Gas/Electric

Packaged Gas/Electric Packaged Gas/Electric Units Owner's Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK HAZARD. FIRE OR EXPLOSION HAZARD Failure to follow this warning can result in Disconnect power

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

Mini-Rooter Operating Instructions

Mini-Rooter Operating Instructions Mini-Rooter Operating Instructions For 1-1/4 through 4 lines (30mm 100mm) Your Mini-Rooter is designed to give you years of trouble-free, profitable service. However, no machine is better than its operator.

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range Corporation Front Street Greenwood, Mississippi 38930 USA (66) 455-00 For product information, visit the Viking Web site at vikingrange.com Professional Built-In

More information

3.5-GALLON PARTS WASHER OWNER S MANUAL

3.5-GALLON PARTS WASHER OWNER S MANUAL 3.5-GALLON PARTS WASHER OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious

More information

Installation Requirements for Models:

Installation Requirements for Models: 900 & 9100 Series Refrigerators Installation Requirements for Models: 9162 9163 9182 9183 962 963 982 983 WARNING Improper installation, adjustment, alteration, service, or maintenance can cause injury

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW/HORIZONTAL & DOWNFLOW TWO STAGE INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this manual is not

More information

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE 58CLA OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. WELCOME TO A NEW GENERATION

More information

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING FLAME115 INFRARED HEATER SERVICE MANUAL INDEX 1. CONTROLS AND COMPONENTS 2. FLAME CONTROL CYCLES 3. MAINTENANCE SCHEDULE 4. TROUBLESHOOTING GUIDE 5. REPAIR PROCEDURES 1. FAN MOTOR ASSEMBLY 2. FUEL FILTER

More information

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended

More information

User s Information Manual

User s Information Manual 48N2,N3,N4,N5,N6,N7,N8,N9 75-150 Ton Gas Heating/Electric Cooling Units with ComfortLink Controls User s Information Manual NOTE TO INSTALLER: This manual should be left with the equipment owner. : If

More information

This document was created with FrameMaker 4.0.4

This document was created with FrameMaker 4.0.4 This document was created with FrameMaker.0. WELCOME TO TODAY S GENERATION OF COMFORT Congratulations! Your new, higher efficiency gas furnace is a sound investment which will reward you and your family

More information

PS /2 Inch Angle Grinder Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT.

PS /2 Inch Angle Grinder Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. PS07214 4 1/2 Inch Angle Grinder Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.

More information

User's Infomation Manual

User's Infomation Manual User's Infomation Manual 574A GAS HEATING/ELECTRIC COOLING Cancels: OM01-69 OM10-28 02-07 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Note to Installer:

More information

Operator s Manual. Portable Generator GP 3800A

Operator s Manual. Portable Generator GP 3800A Operator s Manual Portable Generator GP 3800A EN 5000192885 01 0511 5 0 0 0 1 9 2 8 8 5 Copyright notice Copyright 2011 by Wacker Neuson Production Americas LLC All rights, including copying and distribution

More information

Revision B Printed Fall Elston Manufacturing HC Heater Owners Manual

Revision B Printed Fall Elston Manufacturing HC Heater Owners Manual Revision B Printed Fall 2007 Elston Manufacturing HC Heater Owners Manual Table of Contents Important Safety Information... ii 1) Description of Heater... 1 General information about your heater including

More information

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. c_::_':_-_:_ r'" _" "_1 WARNING: If the information in this manual is not followed exactly, a fire or explosion may Iresult causing property damage, personal injury or [loss of life. m m m Do not store

More information

OIL FIRED WARM AIR FURNACE. Homeowner Instructions

OIL FIRED WARM AIR FURNACE. Homeowner Instructions OIL FIRED WARM AIR FURNACE Homeowner Instructions Fire, explosion, asphyxiation and electrical shock hazard. Improper installation and operation could result in death or serious injury. Read this manual

More information

USER S INFORMATION MANUAL (2,4)SG13B

USER S INFORMATION MANUAL (2,4)SG13B USER S INFORMATION MANUAL (2,4)SG13B Series Gas Heating/Electric Cooling Package Unit Congratulations......your outdoor heating/cooling package unit is a valuable piece of equipment, designed and manufactured

More information

KEROSENE FORCED AIR HEATER

KEROSENE FORCED AIR HEATER KEROSENE FORCED AIR HEATER operation manual HK125RW HK300RW 2 table of contents Safety 6 Safety Rules 7 Safety Warnings Specifications 12 Specifications 13 Wiring Diagram Pre-Operation 14 General Instructions

More information

User s Information Manual

User s Information Manual 62DA,DB,DC,DD07-38 Vertical or Horizontal Dedicated 100% Outdoor Air Unit with Optional Gas Heat User s Information Manual NOTE TO INSTALLER This manual should be left with the equipment owner. : If the

More information

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741

More information

en Indirect-fired Air Heater. Cub 400 Cub 700 OPERATOR S MANUAL

en Indirect-fired Air Heater. Cub 400 Cub 700 OPERATOR S MANUAL 0170815en 004 0907 Indirect-fired Air Heater Cub 400 Cub 700 OPERATOR S MANUAL 0 1 7 0 8 1 5 E N Cub 400/700 Table of Contents 1. Foreword 3 2. Safety Information 5 2.1 Operating Safety... 6 2.2 Operator

More information

10.1 Troubleshooting Condition Table

10.1 Troubleshooting Condition Table 10.1 Troubleshooting Condition Table Behavior 01. The furnace does not operate when you set the wall thermostat to a high temperature. Component 1. Wall T-Stat (See Section 10.3) 2. Blower/Fan Limit (See

More information

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE TROUBLESHOOTING INTEGRATED FURNACE Failure to read and follow all instructions carefully before installing or operating this control, could cause personal injury and/ or property damage. 50A55 INTEGRATED

More information

BK5 Bug Killer. Read all instructions before using the bug killer. Contents

BK5 Bug Killer. Read all instructions before using the bug killer. Contents Read all instructions before using the bug killer Contents 1) Components... 3 Total Assembly... 3 2) Specifications... 4 3) Receiving... 4 4) Safety... 5 a) Power connections... 6 b) Control power... 6

More information

User s Information Manual

User s Information Manual 48AJ,AK,AW,AY020-060 Single-Package Rooftop Gas Heating Units with COMFORTLINK Controls and Scroll Compressors User s Information Manual NOTE TO INSTALLER This manual should be left with the equipment

More information

50A Integrated Furnace Control

50A Integrated Furnace Control Goodman White-Rodgers 0130F00005 PCBBF110 PCBBF123 50A55-743 0130F00005S PCBBF110S PCBBF123S 50A55-289 B1809926 PCBBF112 50T55-289 B1809926S PCBBF112S 50A55-743 Integrated Furnace Control INSTALLATION

More information

ZCR 3824 SAFETY INFORMATION AND OPERATIONS MANUAL

ZCR 3824 SAFETY INFORMATION AND OPERATIONS MANUAL ZCR 3824 SAFETY INFORMATION AND OPERATIONS MANUAL Read these instructions completely before beginning installation. Failure to follow them could cause a heater malfunction resulting in serious injury and/or

More information

Owner's Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Owner's Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. Induced Combustion Gas Furnace Owner's Manual NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS FOR FUTURE REFERENCE.

More information

Single-Point Mini Hydrostatic Sensor for Double-Wall Sumps

Single-Point Mini Hydrostatic Sensor for Double-Wall Sumps Manual No: 577013-838 Revision: B Single-Point Mini Hydrostatic Sensor for Double-Wall Sumps Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including,

More information

Refrigerant Recovery Machine. Model No Operating Manual

Refrigerant Recovery Machine. Model No Operating Manual Refrigerant Recovery Machine Model No. 25700 Operating Manual Safety Precautions WARNING : TO PREVENT PERSONAL INJURY AND / OR EQUIPMENT DAMAGE, CAUTION - Risk of injury. This equipment should only be

More information

4-GALLON MOBILE PARTS WASHER

4-GALLON MOBILE PARTS WASHER Please read and save these instructions. Read through this owner s manual carefully before using product. Protect yourself and others by observing all safety information, warnings, and cautions. Failure

More information

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS: U S E R S I N F O R M AT I O N MANUAL 2017 Lennox Industries Inc. Dallas, Texas, USA SL280UHNV SERIES 507650-01 10/2017 Improper installation, adjustment, alteration, service or maintenance can cause property

More information

Hot Surface Ignition (HSI) System Booklet

Hot Surface Ignition (HSI) System Booklet Hot Surface Ignition (HSI) System Booklet American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com 010298MFM/abe

More information

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

Installation Instructions Dual Fuel Ranges

Installation Instructions Dual Fuel Ranges Installation Instructions Dual Fuel Ranges E30DF74EPS E36DF76EPS E48DF76EPS 5995447082 2 Safety IMPORTANT SAFETY INSTRUCTIONS Safety Precautions Do not attempt to install or operate your unit until you

More information

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY Bousquet Technologies Inc. 2121, Nobel, Ste Julie, Quebec, Canada, J3E1Z9 SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL Oil-Fired air heater for industrial and commercial use. FOR YOUR SAFETY Do not

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-1000TR INDIRECT FIRED HEATER TRAILER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-1000TR INDIRECT FIRED HEATER TRAILER OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-1000TR INDIRECT FIRED HEATER TRAILER CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 50A55-286 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR

More information

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04 prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2004-28 TSG-SOLO-9/04 Table of Contents INTRODUCTION Page 1 SERVICING TIPS AND INSTRUCTIONS Page 3 CONTROL MODULE DISPLAY -

More information

Direct Vent. Oil Fired Warm Air Furnaces INSTALLATION, OPERATION & MAINTENANCE MANUAL WARNING NOTICE

Direct Vent. Oil Fired Warm Air Furnaces INSTALLATION, OPERATION & MAINTENANCE MANUAL WARNING NOTICE Direct Vent Oil Fired Warm Air Furnaces INSTALLATION, OPERATION & MAINTENANCE MANUAL! WARNING Fire, explosion, asphyxiation and electrical shock hazard. Improper installation could result in death or serious

More information

Operator s Manual. Vibratory Rammer BS 65-V

Operator s Manual. Vibratory Rammer BS 65-V Operator s Manual Vibratory Rammer BS 65-V EN 5000184296 06 0712 5 0 0 0 1 8 4 2 9 6 Copyright notice Copyright 2012 by Wacker Neuson Production Americas LLC All rights, including copying and distribution

More information

Condensing Models. On-Demand Water Heater Service Handbook

Condensing Models. On-Demand Water Heater Service Handbook Condensing Models On-Demand Water Heater Service Handbook MODELS: 240 Indoor (T-H3J-DV) 240 Outdoor (T-H3J-OS) 340 Indoor (T-H3S-DV) 340 Outdoor (T-H3S-OS) 540 Indoor (T-H3-DV) 540 Outdoor (T-H3-OS) Series

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 50A66-743 Integrated Furnace Control Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL

More information

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS 21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 031-01284-000/50A55-241 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR

More information

SHELTER HEATER 60,000 BTU Multi-fuel Shelter Heater

SHELTER HEATER 60,000 BTU Multi-fuel Shelter Heater ` MV60-EU Series Heaters, 220 VAC, 50-60 Hz SHELTER HEATER 60,000 BTU Multi-fuel Shelter Heater Operation and Maintenance Manual HDT Tactical Systems Business Unit 30525 Aurora Rd Solon, Ohio 44139-2795

More information

Owner s Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Owner s Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. Induced Combustion Gas Furnace NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. Owner s Manual CERTIFIED USER: Please read all instructions in the manual and retain all manuals for

More information

V SERIES HDR GAS RANGES

V SERIES HDR GAS RANGES SERVICE MANUAL ONE POWERFUL PACKAGE V SERIES HDR GAS RANGES TOPS Open Top Hot Top Griddle Top Work Surface BASES Standard Oven Convection Oven Cabinet Base - NOTICE - This manual is prepared for use by

More information

Installation Instructions Part No

Installation Instructions Part No Heat Exchanger Cell Kit Cancels: New Installation Instructions Part No. 326600-751 IIK-310A-45-6 6-02 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing

More information

Operator s Manual. Vibratory Rammer. BS 60-4s

Operator s Manual. Vibratory Rammer. BS 60-4s Operator s Manual Vibratory Rammer BS 60-4s EN 5000184266 03 0612 5 0 0 0 1 8 4 2 6 6 Copyright notice Copyright 2012 by Wacker Neuson Production Americas LLC All rights, including copying and distribution

More information

Operator s Manual. Floor Vac Model No. VF408 FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference

Operator s Manual. Floor Vac Model No. VF408 FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference Wet/Dry Vacuums Operator s Manual Floor Vac Model No. VF408 FOR YOUR SAFETY Read and understand this manual before use Keep this manual for future reference www.vacmaster.com Cleva North America 44 Parkway

More information

Technical

Technical NOx 75 & 98 Gallon This technical bulletin applies to the 75 and 98 gallon NOx residential product manufactured for the California market. No Power or No Blower Motor Nothing happens at all. No blower

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY...................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE..........

More information

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler ClearFire Model CFH Horizontal Steam Boiler Startup Guide 750-293 www.cleaverbrooks.com Improper installation, adjustment, service, or maintenance can cause equipment damage, personal injury, or death.

More information

Owner's Guide to Operating and Maintaining Your Gas/Electric Unit

Owner's Guide to Operating and Maintaining Your Gas/Electric Unit Packaged Gas Heat/Electric Cooling Units Owner's Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK. FIRE OR EXPLOSION Failure to follow this warning could result in personal injury,

More information

No. Of Ignition Trials: No. Of Re-Ignition Attempts. Reset by interrupting power for 5.0 Seconds. Diagnostic Output. Re-Ignition Limit Exceeded

No. Of Ignition Trials: No. Of Re-Ignition Attempts. Reset by interrupting power for 5.0 Seconds. Diagnostic Output. Re-Ignition Limit Exceeded DS1-Q INSTALLATION INSTRUCTIONS General Description Model DS1-Q is used to replace and eliminate the factory installed slow responding glow-bar igniter, sensor and associated wiring in commercial laundry

More information

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions IFT-RC150 IntelliFire Touch Remote Control Installation Instructions Leave this manual with party responsible for use and operation. 1. Introduction The IFT-RC150 is a wall mounted device that is designed

More information

Direct Vent. Oil Fired Warm Air Furnaces INSTALLATION, OPERATION & MAINTENANCE MANUAL WARNING

Direct Vent. Oil Fired Warm Air Furnaces INSTALLATION, OPERATION & MAINTENANCE MANUAL WARNING Direct Vent Oil Fired Warm Air Furnaces INSTALLATION, OPERATION & MAINTENANCE MANUAL! WARNING Fire, explosion, asphyxiation and electrical shock hazard. Improper installation could result in death or serious

More information

A-1106 ACCESSORY KIT INSTALLATION INSTRUCTIONS IGNITION CONTROL P/N S , S , S

A-1106 ACCESSORY KIT INSTALLATION INSTRUCTIONS IGNITION CONTROL P/N S , S , S ACCESSORY KIT INSTALLATI INSTRUCTIS IGNITI CTROL P/N S1-33101972200, S1-37326083000, S1-43101972100 FOR USE WITH THE FOLLOWING FURNACE MODELS: GY9, GF9, GM9, P1UK, PAKU, P2MP, P2MPV, P9MP, P2UR, PBLU,

More information

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS 50M56-743 Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD

More information