1 Bohn Authorized Parts For Original Equipment

2 Bohn InterLink Parts for Bohn Table of Contents Reach-In Evaporators BBM/LM/LS 6 BTO 32 C 34 KM 64 RAM 92 TA 97 TL VA 04 Evaporators ADT 3 ADT J Vintage 4 ADT K Vintage 5 BHA 0- BHE 2-4 BHF 5-7 BHG 8-20 BHL 2-23 BMA/E/G/L/F 29 EDT 42 EL 43 EM 44 EUC 45 FC 46 FL FM 5-52 HGT A Thru F Vintage 53 HGT J Vintage 54 HGT K Vintage HVC K Vintage 57 HR LC/LM/LR 65 LAT - Extended Thin Profile 80 LET LET J Vintage 68 LET K Vintage 69 LLE 70 LLE K Vintage 7 LO LOD LOG LSC 8 MPA/E/G/L 83 MPE/G/L 84 OKI 85 PA/PE/PG 9 RGT/RL 92 SM 93 SME 94 TE 0 2 U/UC 02 UF/M 03 WK 05 WKE C Vintage 06 WKE/G 07 Refrigeration Systems Beacon I & Beacon II Refrigeration System 30 PRO 3 Top Mount Refrigeration System PRO 3 Side Mount Refrigeration System Condensing Units BLV/BBV 7 BD 8 BZ 9 BH/S/Z 24 BLH/BBH 26 BRI/BDI CB/CL/CBH/CS 35 CB/CL/MB/ML 36 D 37 E 4 HW/Z 60 JB/L/S 6 JBD/JLD 62 JH/RH/JS 63 SBH/SLN/SLH/HLN/HBH/HLH 95 SRN/SWN 96 Air-Cooled Condensers BRL/H/Q/X 3 BNH/BNL/BNX/BNQ/BNE 3 BVF/BHF/BFF 33 DFT 38 DVT 39 DV 40 RVB, BFC, Rev. A & B 08 Fluid Coolers BFH 25 More from Bohn Refrigeration Brushless DC Motor 09 EC Motor 09 Hot Gas Defrost 08 McDonald s 82 Smart Defrost Kit 08

3 ADT Air Defrost Evaporators Nomenclature Example: ADT 20 A Model Series Capacity Electrical Characteristics Design Revision ADT = Air Defrost Size X 00 = BTUH A = 5//60 B = //60 M = 460//60 Bohn ADT Units Fan Motor Fan Drain Drain Unit Motor Qty Blade Mount Guard Pan Fitting 2 520ADT ADT ADT 5034LS 2 532C E ADT N/A 350ADT ADT ADT LS 532C E ADT N/A 3000ADT ADT 520A ADT 700A ADT 900A 5034LS 2 532C E N/A ADT040A ADT350A ADT560A ADT2080A 5034LS 4 532C E ADT2540A N/A ADT3000A Note: 230V units use 5034MS Motor 2 May use Part No ; however, angle R-Side Panel Electrical End is slightly different and may require repiping L-Side Panel TXV End B thru G Vintage Fan Motor Fan Drain Drain Unit Motor 3 Qty Blade Mount 5 Guard 4 Pan Fitting ADT0400B-G C25924A2 ADT0520B-G 5008SS 540C X C25924A2 ADT0650B-G C25924A2 ADT0700B-G 2 C25925A2 ADT0900B-G 2 C25925A2 ADT040B-G 5008SS 2 540C X C25926A2 ADT300B-G 2 C25926A2 ADT560B-G 3 C25927A2 ADT2080B-G 4 C25928A2 ADT2600B-G 5008SS 5 540C X C25929A2 ADT320B-G 6 C25930A2 ADT3700B-G 6 C25930A2 Optional Parts: 3 Motor, 5//50-60 (PSC) 5008N Side Panel, Left C2988A - TXV End 3 Motor, // TS Side Panel, Right C2989A - Electrical End 3 Motor, //50-60 (PSC) 5008PS 4 Fan Guard, Round Wire PVC - Part no. 5070E 5 Motor Mount & Template

4 ADT J Vintage Air Defrost Evaporators Bohn ADT Units (AJ== 5V) (BJ =230V) Fan Motor Fan Drain Drain Unit Motor Qty Blade Mount 2 Guard 2 Pan Fitting ADT040 C25924A2 ADT S D294A X C25924A2 ADT065 C25924A2 ADT070 2 C25925A2 ADT090 2 C25925A2 ADT S 2 D294A X C25926A2 ADT30 2 C25926A2 ADT56 3 C25927A2 ADT208 4 C25928A2 ADT S 5 D294A X C25929A2 ADT32 6 C25930A2 ADT370 6 C25930A2 Optional Parts Motor, //50/ S 2 Wire Guard E Motor, 5//50-60 (PSC) S Motor, //50-60 (PSC) S 2 Motor Mount & Template Note: ADT Models Ending with ASWJ : SW = Solenoid Wire ADT Models Ending with ASWGJ : SW = Solenoid Wire & Wire Guard (4542Z) 4

5 ADT K Vintage Air Defrost Evaporators ADT Units Model No. Motor Motor Fan Motor Drain No. Mtr 5V. 230V Blade Mount Guard 2 Pan 3 ADT040 ADT S S 540C ADT065 ADT070 ADT090 ADT S S 540C ADT20 ADT30 ADT40 ADT S S 540C ADT80 ADT S S 540C ADT S S 540C ADT S S 540C ADT S S 540C Optional Wire Guard: Pt. No Drain Fitting Part No size 40 & 52 - no dist - no nozzle Bohn Optional Motors: Part No. Description //60/50 Totally Enclosed PSC //60/50 Totally Enclosed PSC //60/50 Totally Enclosed PSC //60/50 PSC //60/50 PSC Cabinet Components (All Sizes) Part No. Description Access Panel - Elect-RH Access Panel - Refrig-LH Access Panel - Refrig - Beacon II Back Panel - Refrig Back Panel - Elect 5

6 Bohn BB Back Bar Units BBL/BBLM/BBLS *Drain fitting included in pan Hot Gas & Electric Defrost Evaporators Fan Motor Fan Drain Unit Motor Qty Blade Mount Guard Pan* BBLM0A BBLM5A S 2 509E D BBLS0A BBLS5A BBL0A S 509E D BBL5A T stat Defrost Coil Drain Pan Unit Solenoid TX Valve Switch T stat Heater Heater BBLM0A L BBLM5A C BBLS0A L BBLS5A C BBL0A L BBL5A C Air Deflector Part No. : for size for size 5 BBM/BBMM/BBMS Fan Fan Drain Model Motor Blade Guard Solenoid TX Valve T stat Pan BBMMA BBMM6A BBMSA S 509E 5054D BBMS6A BBMA BBM6A Motor Mount Part No Air Deflector Part No: For size For size 6 BC Bottle Coolers Fan Motor Fan Drain Unit Motor Qty. Blade Mount Guard Pan* BC2AE W523 BC6AE R R R BC22AE *Drain Fitting: () Nut Part No. R and () Stud Part No. R Hot Gas & Electric Defrost Evaporators 6

7 BLV / BBV 0-40 HP Nomenclature Example: BL V 500 L 6 C Nominal Horsepower Application Refrigerant Voltage BL - Limitizer V - Vertical Discharge 200/20-0 HP 2700/ HP L - Low 2-HCFC-22 C /60/3 BB - Bohnmizer 500/50-5 HP 3000/ HP H - High 6-HFC-404A or HFC-507 D- 460/60/3 2000/ HP 3500/ HP M - Medium HCFC-22 K - 230/60/ 2200/ HP 3505/ HP C - Commercial E / HP 4000/ HP 2600/ - 25 HP Bohn Common Parts Part Description Part No. Guard High Pressure Control Contactor - 25 A Condenser Motor Contactor - 40 A Compressor Contactor - 50 A Compressor Contactor - 60 A Compressor Contactor - 75 A Compressor Pressure Switch Low Pressure Control Air Defrost Timer Fan Cycling 552R Temperature Fan Cycle Control Pressure Fan Cycle Control Electric Defrost Timer Defrost Fan Contactor 25 A (40A /see Below) Defrost Heater Contactor 40 A Motor & Fan Blade Options: Motor Part No. Description Blade Part No S 3/4 HP - 40 RPM 208/230/460/ S HP RPM 208/230/460/ S /2 HP - 40 RPM 208/230/460/ S /2 HP RPM 208/230/460/ (use 5792V) Slinger For & Note: No Motor Mounts - Uses Motor Rails original blade obsolete - this is closest replacement BLV= Limitizer Unit BBV= Bohnmizer System B*V***C6 HI Eff. W/Oversized Condenser B*V4000 & B*V3503 Spec 230/2/60 Note: Sentronic Oil Control Available From Copeland Must have HP and RPM to select motor or blade 7

8 BD 3-22 HP Condensing Units Bohn Nomenclature Example: B D T 500 L 6 C Model Compressor Placement Equiv. HP Application Refrigerant Voltage B = Bohn D = Discus T = Outdoor 0300 = 3 HP 0900 = 9 HP H = High Temp 2 = R22 C = /3/60 Z = Scroll N = Indoor 0400 = 4 HP 000 = 0 HP M = Med. Temp 6 = 404A, 507 ( /3/50) M = Beacon 050* = 5 HP 200 = 2 HP L = Low Temp D = 460/3/60 B = Bohnmizer 060* = 6 HP 300 = 3 HP /3/50 S = Beacon II 075* = 7.5 HP 400 = 4 HP 0800 = 8 HP 500 = 5 HP 0860 = 8.5 HP 2200 = 22 HP Unit MTR No. Motor Motor Fan Indoor Outdoor Model HP MTR 230V 460V Blade MTR MT MTR MT Grille *D*0300L2 / *D*0400L2 / *D*0600L2 / *D*060L2 / *D*0750L2 / *D*0900L2 / *D*000L2 / *D*200L2 3/4 2 R S R R *D*500L2 3/4 2 R R R *D*2200L2 3/4 2 R R R *D*0500H2 / *D*050H2 / *D*0750H2 / *D*075H2 / *D*0800H2 / *D*000H2 / *D*200H2 / *D*500H2 3/4 2 R S R S R *D*0500M6 / *D*050M6 / T03H00258 (BZT045L6CF) started use of blades supplied by air drive -T03J00365 dated 9/0/03 end note normally use Revcor. Unit MTR No. Motor Motor Fan Indoor Outdoor Model HP MTR 230V 460V Blade MTR MT MTR MT Grille *D*0750M6 / *D*075M6 / *D*0800M6 / *D*000M6 / *D*200M6 / *D*500M6 3/4 2 R S R S R *D*0300L6 / *D*0400L6 / *D*0600L6 / *D*060L6 / *D*0750L6 / *D*0900L6 / *D*000L6 / *D*200L6 3/4 2 R S R S R *D*500L6 3/4 2 R S R S R *D*2200L6 3/4 2 R S R S R Use Capacitor Pt No

9 BZ Unit MTR No. Motor Motor Fan Indoor Outdoor Model HP MTR 230V 460V Blade MTR MT MTR MT Grille *Z*0650H *Z*0650M6 / *Z*0700H *Z*0700M *Z*0750H2 / *Z*0750L *Z*0750L *Z*0750M6 / *Z*0860H *Z*0860M6 *Z*000H2 / *Z*000M6 *Z*000L *Z*000L6 / *Z*000M *Z*200H2 *Z*300L2 / *Z*300L6 *Z*400H2 *Z*400M6 *Z*500L2 *Z*500L6 / Electrical Components Description Part No. Contactor 40A 3P V Contactor 50A 3P V Contactor 60A 3P V Contactor 75A 3P V Contactor 25A V Dual Pressure Contactor MAN 20in -00/ Fan Cycling Switch- Pressure Fan Cycling Switch- Temperature High Pressure Control Fixed, CO Hi Pressure Encap Switch 425#/W/CONN Lo Pressure Fixed Lo Pressure SW- Adjustable P70AB-D Oil Safety Control, Sentronic T stat - Scroll (Discharge Line) Timer (845-20) Transformer 300VA SL300QP R CC Heater Discuss 2D, 3D, 00W/240V CC Heater Scroll 7.5 TO 5HP 80W/240V CC Heater ZB Scrolls 90W/240V Line Components Description Part No. HP Valve ORD HP Valve ORI HP Valve OROA HP Valve OROA Bohn 9

10 BHA Bohn Nomenclature Example: BH A 850 C P A BOHN Large Unit Cooler Fins Per Inch/Defrost Voltage Code Optional Motor Code Vintage A = 6 or 8 FPI Air Defrost Capacity x 00 B = //60 M = 460//60 T = Total Enclosed Motors (Standard motor/fan blade) C = /3/60 V = High CFM Option X = 380/400/3/50 D = 460/3/60 Y = 200/220//50 P = 3 Phase Motor E = 575/3/60 Model No. Fans Motors HP Blades Guards Drain Pan BHA520BA S / BHA520MA S / BHA520CPA S 3/4 533C BHA520DPA S 3/ C BHA520CTA BHA520DTA BHA520EPA /2 533C BHA630BA S 2 BHA630MA S / BHA630CPA S 3/4 BHA630DPA S 3/4 533C BHA630CTA BHA630DTA BHA630EPA /2 533C BHA750BA S / BHA750CA S / BHA750CPA S 3/4 533C BHA750DA S / BHA750DPA S 3/4 533C BHA750CTA C BHA750DTA BHA750EPA /2 533C BHA850BA S / BHA850CA S / BHA850CPA S 3/4 533C BHA850DA S / BHA850DPA S 3/4 533C BHA850CTA C BHA850DTA BHA850EPA /2 533C BHA930BA S / BHA930CA S / BHA930CPA S 3/4 533C BHA930DA S / BHA930DPA S 3/4 533C BHA930CTA C BHA930DTA BHA930EPA /2 533C BHA00BA S / BHA00CA S / BHA00CPA S 3/4 533C BHA00DA S / BHA00DPA S 3/4 533C BHA00CTA C BHA00DTA BHA00EPA /2 533C Motors are mounted on rails 0

11 BHA Continued Model No. Fans Motors HP Blades Guards Drain Pan BHA70CPA S BHA70DPA S BHA70CTA / BHA70DTA /2 BHA70EPA BHA400CPA S BHA400DPA S BHA400CTA / BHA400DTA /2 BHA400EPA BHA60CPA S BHA60DPA S / BHA60CTA BHA60DTA /2 BHA60EPA BHA900CPA S BHA900DPA S / BHA900CTA BHA900DTA BHA900EPA / BHA260CPA S BHA260DPA S / BHA260CTA BHA260DTA BHA260EPA / BHA2200CPA S BHA2200DPA S / BHA2200CTA BHA2200DTA /2 BHA2200EPA BHA2500CPA S BHA2500DPA S / BHA2500CTA BHA2500DTA /2 BHA2500EPA BHA2440CPA S BHA2440DPA S / BHA2440CTA BHA2440DTA BHA2440EPA / BHA2780CPA S BHA2780DPA S / BHA2780CTA BHA2780DTA BHA2780EPA / Motors are mounted on rails - no motor mounts Unit Size Side Panel Left Back Panel (Ref. Conn) 520, 630, 750, 859, 930, , , , , Bohn

12 BHE Bohn Nomenclature Example: BH E 850 C P A BOHN Large Unit Cooler Fins Per Inch/Defrost Voltage Code Optional Motor Code Vintage E = 6 FPI Electric Defrost Capacity x 00 B = //60 M = 460//60 T = Total Enclosed Motors (Standard motor/fan blade) C = /3/60 X = 380/400/3/50 V = High CFM Option D = 460/3/60 Y = 200/220//50 P = 3 Phase Motor E = 575/3/60 Model # Fans Motors Blades Guards Coil Heater Qty Pan Heater* Drain Pan BHE450BA S BHE450CA S BHE450CPA S 533C BHE450DA S BHE450DPA S 533C BHE450CTA C BHE450DTA C BHE450EPA C BHE450CVA 596F BHE450DVA 596F BHE550BA S BHE550CA S BHE550CPA S 533C BHE550DA S BHE550DPA S 533C BHE550CTA C BHE550DTA C BHE550EPA C BHE550CVA 596F BHE550DVA 596F BHE640CA S BHE640CPA S 533C BHE640DA S BHE640DPA S BHE640CTA C BHE640DTA BHE640EPA C BHE640CVA 3 596F BHE640DVA 596F BHE740CA S BHE740CPA S 533C 3 BHE740DA S BHE740DPA S 533C BHE740CTA BHE740DTA C BHE740EPA BHE740CVA BHE740DVA 3 596F BHE80CA S BHE80CPA S 533C BHE80DA S BHE80DPA S BHE80CTA C BHE80DTA BHE80EPA C BHE80CVA 4 596F BHE80DVA 596F Heater Limit T stat - Part No. 5708L *(2) Pan Heaters required per unit Defrost Termination & Fan Delay - Part No. 4267W Heater clips Part No Motors are mounted on rails

13 BHE Continued Model # Fans Motors Blades Guards Coil Heater Qty Pan Heater* Drain Pan BHE950CA S BHE950CPA S 533C BHE950DA S BHE950DPA S BHE950CTA C BHE950DTA BHE950EPA C BHE950CVA 4 596F BHE950DVA 596F Heater Limit T stat - Part No. 5708L *(2) Pan Heaters required per unit Bohn Defrost Termination & Fan Delay - Part No. 4267W Heater clips Part No Motors are mounted on rails - no motor mounts Model # Fans Motors Blades Guards Coil Heater Qty Pan Heater* Drain Pan BHE020CPA BHE020DPA S BHE020CTA BHE020DTA BHE020EPA BHE020CVA BHE020DVA J BHE200CPA BHE200DPA BHE200CTA BHE200DTA BHE200EPA BHE200CVA BHE200DVA J BHE390CPA BHE390DPA S BHE390CTA BHE390DTA BHE390EPA BHE390CVA BHE390DVA J HP motors #(2) Pan Heaters required per unit 2 /2 HP Motors Heater Limit T stat - Part No. 4752C 3 3 HP Motors Defrost Termination & Fan Delay - Part No. 4267W 4 Motors are mounted on rails - no motor mounts Heater clips Part No

14 BHE Continued Bohn Model # Fans Motors Blades Guards Coil Heater Qty Pan Heater* Drain Pan BHE650CPA BHE650DPA S V V BHE650CTA BHE650DTA V BHE650EPA V BHE650CVA J V BHE650DVA V BHE650CPB S V BHE650DPB V BHE650CTB BHE650DTB V V BHE650EPB BHE650CVB J V BHE650DVB V Defrost Control-Fan Delay - Part No. 4267W * (2) Pan Heaters required per unit Heater Limit T stat - Part No. 5708L Heater clips Part No Motors are mounted on rails - no motor mounts Model # Fans Motors Blades Guards Coil Heater Qty Pan Heater* Drain Pan BHE220CPA BHE220DPA S BHE220CTA BHE220DTA BHE220EPA BHE220CVA BHE220DVA J Defrost Control-Fan Delay - Part No. 4267W * (4) Pan Heaters required per unit Heater Limit T stat - Part No. 5708L Heater clips Part No Motors are mounted on rails - no motor mounts Model Size Left Back Panel Electric & Hot Gas Defrost Side Panel (Ref. Conn) 400,450,480, ,640,650, ,80,840, ,020,050, , , ,

15 BHF Nomenclature Example: BH F 850 C P A BOHN Large Unit Cooler Fins Per Inch/Defrost Voltage Code Optional Motor Code Vintage F = 4 FPI Hot Gas Defrost Capacity x 00 B = //60 M = 460//60 T = Total Enclosed Motors (Standard motor/fan blade) C = /3/60 X = 380/400/3/50 V = High CFM Option D = 460/3/60 Y = 200/220//50 P = 3 Phase Motor E = 575/3/60 Bohn Pan* Electric Hot Gas Model # Fans Motors HP Blades Guards Heater Drain Pan Drain Pan BHF400BA S / BHF400MA S / BHF400CPA S 3/4 533C BHF400DPA S 3/4 BHF400CTA C BHF400DTA BHF400EPA /2 533C BHF400CVA 2 596F BHF400DVA 596F BHF480BA S / BHF480MA S / BHF480CPA S 3/4 533C BHF480DPA S 3/4 BHF480CTA C BHF480DTA BHF480EPA /2 533C BHF480CVA 2 596F BHF480DVA 596F BHF560BA S / BHF560CA S / BHF560CPA S 3/4 533C BHF560DA S / BHF560DPA S 3/4 533C BHF560CTA C BHF560DTA C BHF560EPA /2 533C BHF560CVA 3 596F BHF560DVA 596F BHF650BA S / BHF650CA S / BHF650CPA S 3/4 533C BHF650DA S / BHF650DPA S 3/4 533C BHF650CTA C BHF650DTA C BHF650EPA /2 533C BHF650CVA 3 596F BHF650DVA 596F Thermostat Part No. 5893Q Defrost Term & Fan Delay Part No. 4267W Motors are mounted on rails *Quantity of 2 used only on electric model 5

16 BHF Continued Bohn Pan Electric Hot Gas Model # Fans Motors HP Blades Guards Heater Drain Pan Drain Pan BHF70BA S / BHF70CA S / BHF70CPA S 3/4 533C BHF70DA S / BHF70DPA S 3/4 533C BHF70CTA C BHF70DTA C BHF70EPA /2 533C BHF70CVA 4 596F BHF70DVA 596F BHF840BA S / BHF840CA S / BHF840CPA S 3/4 533C BHF840DA S / BHF840DPA S 3/4 533C BHF840CTA C BHF840DTA C BHF840EPA /2 533C BHF840CVA 4 596F BHF840DVA 596F BHF890CPA BHF890DPA S BHF890CTA BHF890DTA / BHF890EPA BHF890CVA BHF890DVA J BHF050CPA BHF050DPA S BHF050CTA BHF050DTA / BHF050EPA BHF050CVA BHF050DVA J BHF220CPA BHF220DPA S / BHF220CTA BHF220DTA / BHF220EPA BHF220CVA BHF220DVA J Thermostat Part No. 5893Q Defrost Term & Fan Delay Part No. 4267W Motors are mounted on rails *Quantity of 2 used only on electric model 6

17 BHF Continued Pan* Electric Hot Gas Model # Fans Motors HP Blades Guards Heater Drain Pan Drain Pan BHF440CPA BHF440DPA S / BHF440CTA BHF440DTA / BHF440EPA BHF440CVA BHF440DVA J Thermostat Part No Defrost Term & Fan Delay Part No. 4267W Motors are mounted on rails - no motor mounts *Quantity of 2 used only on electric model Bohn Pan* Electric Hot Gas Model # Fans Motors HP Blades Guards Heater Drain Pan Drain Pan BHF860CPA BHF860DPA S / BHF860CTA BHF860DTA / BHF860EPA BHF860CVA BHF860DVA J Thermostat Part No Defrost Term & Fan Delay Part No. 4267W Motors are mounted on rails - no motor mounts *Quantity of 4 used only on electric model Model Size Left Back Panel Electric & Hot Gas Defrost Side Panel (Ref. Conn) 400,450,480, ,640,650, ,80,840, ,020,050, , , ,

18 BHG Bohn Nomenclature Example: BH G 850 C P A BOHN Large Unit Cooler Fins Per Inch/Defrost Voltage Code Optional Motor Code Vintage G = 6 FPI Hot Gas Defrost Capacity x 00 B = //60 M = 460//60 T = Total Enclosed Motors (Standard motor/fan blade) C = /3/60 X = 380/400/3/50 V = High CFM Option D = 460/3/60 Y = 200/220//50 P = 3 Phase Motor E = 575/3/60 Drain Pan Electric Hot Gas Model # Fans Motors HP Blades Guards Heater* Drain Pan Drain Pan BHG450BA S / BHG450MA S / BHG450CPA S 3/4 533C BHG450DPA S 3/ BHG450CTA C BHG450DTA BHG450EPA /2 533C BHG450CVA 2 596F BHG450DVA 596F BHG550BA S / BHG550MA S / BHG550CPA S 3/4 533C BHG550DPA S 3/4 BHG550CTA C BHG550DTA BHG550EPA /2 533C BHG550CVA 2 596F BHG550DVA 596F BHG640BA S / BHG640CA S / BHG640CPA S 3/4 533C BHE640DA S / BHG640DPA S 3/4 533C 3 BHG640CTA C BHG640DTA C BHG640EPA /2 533C BHG640CVA 3 596F BHG640DVA 596F BHG740BA S / BHG740CA S / BHG740CPA S 3/4 533C BHG740DA S / BHG740DPA /4 533C 3 BHG740CTA C BHG740DTA C BHG740EPA /2 533C BHG740CVA 3 596F BHG740DVA 596F Thermostat Part No. 5893Q Defrost Term & Fan Delay Part No. 4267W Motors are mounted on rails *Quantity of 2 used only on electric model 8

19 BHG Continued Drain Pan Electric Hot Gas Model # Fans Motors HP Blades Guards Heater* Drain Pan Drain Pan BHG80BA S / BHG80CA S / BHG80CPA S 3/4 533C BHG80DA S / BHG80DPA S 3/4 533C 4 BHG80CTA C BHG80DTA C BHG80EPA /2 533C BHG80CVA 4 596F BHG80DVA 596F BHG950BA S / BHG950CA S / BHG950CPA S 3/4 533C BHG950DA S / BHG950DPA S 3/4 533C 4 BHG950CTA C BHG950DTA C BHG950EPA /2 533C BHG950CVA 4 596F BHG950DVA 596F BHG020CPA BHG020DPA S BHG020CTA BHG020DTA / BHG020EPA BHG020CVA BHG020DVA J BHG200CPA BHG200DPA S BHG200CTA BHG200DTA / BHG200EPA BHG200CVA BHG200DVA J BHG390CPA BHG390DPA S / BHG390CTA BHG390DTA / BHG390EPA BHG390CVA BHG390DVA J Thermostat Part No. 5893Q Defrost Term & Fan Delay Part No. 4267W Motors are mounted on rails BHG *Quantity of 2 used only on electric model Continued Bohn 9

20 BHG Continued Bohn Drain Pan Electric Hot Gas Model # Fans Motors HP Blades Guards Heater* Drain Pan Drain Pan BHG650CPA BHG650DPA S / BHG650CTA BHG650DTA / BHG650EPA BHG650CVA BHG650DVA J Thermostat Part No Defrost Term & Fan Delay Part No. 4267W Motors are mounted on rails *Quantity of 2 used only on electric model Drain Pan Electric Hot Gas Model # Fans Motors HP Blades Guards Heater* Drain Pan Drain Pan BHG220CPA BHG220DPA S / BHG220CTA BHG220DTA / BHG220EPA BHG220CVA BHG220DVA J Thermostat Part No Defrost Term & Fan Delay Part No. 4267W Motors are mounted on rails *Quantity of 4 used only on electric model Model Size Left Back Panel Electric & Hot Gas Defrost Side Panel (Ref. Conn) 400,450,480, ,640,650, ,80,840, ,020,050, , , ,

21 BHL Nomenclature Example: BH L 850 C P A BOHN Large Unit Cooler Fins Per Inch/Defrost Voltage Code Optional Motor Code Vintage L = 4 FPI Electric Defrost Capacity x 00 B = //60 M = 460//60 T = Total Enclosed Motors (Standard motor/fan blade) C = /3/60 X = 380/400/3/50 V = High CFM Option D = 460/3/60 Y = 200/220//50 P = 3 Phase Motor E = 575/3/60 Bohn Model # Fans Motors Blades Guards Coil Heater Qty Pan Heater* Drain Pan BHL400BA S BHL400CA S BHL400CPA S 533C BHL400DA S BHL400DPA S 533C BHL400CTA C BHL400DTA C BHL400EPA C BHL400CVA 2 596F BHL400DVA 596F BHL480BA S BHL480CA S BHL480CPA S 533C BHL480DA S BHL480DPA S 533C BHL480CTA C BHL480DTA C BHL480EPA C BHL480CVA 2 596F BHL480DVA 596F BHL560CA S BHL560CPA S 533C BHL560DA S BHL560DPA S BHL560CTA C BHL560DTA BHL560EPA C BHL560CVA 3 596F BHL560DVA 596F BHL650CA S BHL650CPA S 533C BHL650DA S BHL650DPA S BHL650CTA C BHL650DTA BHL650EPA C BHL650CVA 3 596F BHL650DVA 596F BHL70CA S BHL70CPA S 533C BHL70DA S BHL70DPA S BHL70CTA C BHL70DTA BHL70EPA C BHL70CVA 4 596F BHL70DVA 596F Heater Limit T stat - Part No. 5708L *(2) Pan Heaters required per unit Defrost Termination & Fan Delay - Part No. 4267W Heater clips Part No Motors are mounted on rails BHL 2

22 BHL Continued Bohn Model # Fans Motors Blades Guards Coil Heater Qty Pan Heater* Drain Pan BHL840CA S BHL840CPA S 533C BHL840DA S BHL840DPA S BHL840CTA C BHL840DTA BHL840EPA C BHL840CVA 4 596F BHL840DVA 596F Heater Limit T stat - Part No. 5708L *(2) Pan Heaters required per unit Defrost Termination & Fan Delay - Part No. 4267W Heater clips Part No Model # Fans Motors Blades Guards Coil Heater Qty Pan Heater* Drain Pan BHL890CPA BHL890DPA S* BHL890CTA 25300** BHL890DTA ** BHL890EPA ** BHL890CVA BHL890DVA J*** BHL050CPA BHL050DPA S* BHL050CTA 25300** BHL050DTA ** BHL050EPA ** BHL050CVA BHL050DVA J*** BHL220CPA BHL220DPA S** BHL220CTA 25300** BHL220DTA ** BHL220EPA ** BHL220CVA BHL220DVA J*** * HP motors *(2) Pan Heaters required per unit ** /2 HP Motors Heater Limit T stat - Part No. 4752C *** 3 HP Motors Defrost Termination & Fan Delay - Part No. 4267W Heater clips Part No Motors are mounted on rails 22

23 BHL Continued Model # Fans Motors Blades Guards Coil Heater Qty Pan Heater* Drain Pan BHL440CPA S BHL440DPA BHL440CTA BHL440DTA BHL440EPA BHL440CVA BHL440DVA J BHL440CPB BHL440DPB S BHL440CTB BHL440DTB BHL440EPB BHL440CVB BHL440DVB J Defrost Control-Fan Delay - Part No * (2) Pan Heaters required per unit Heater Limit T stat - Part No Heater clips Part No Motors are mounted on rails - no motor mounts Bohn Model # Fans Motors Blades Guards Coil Heater Qty Pan Heater* Drain Pan BHL860CPA BHL860DPA S BHL860CTA BHL860DTA BHL860EPA BHL860CVA BHL860DVA J Defrost Control-Fan Delay - Part No. 4267W * (4) Pan Heaters required per unit Heater Limit T stat - Part No Heater clips Part No Motors are mounted on rails - no motor mounts Model Size Left Back Panel Electric & Hot Gas Defrost Side Panel (Refrig. Conn.) 400,450,480, ,640,650, ,80,840, ,020,050, , , ,

24 BH/S/Z Bohn Nomenclature Example: B Z T 30 L 6 C E Model Compressor Application Equiv. HP Temp. Refrigerant Voltage Identifier B=Bohn H=Hermetic T=Outdoor 005=/2 HP H=High 2=R22 B= //60 F=Stock S=Semi-herm. N=Indoor 008/009=3/4HP L=Low 6=R404A/507 C=208/230/3/60 Z=Scroll B=Bohnmizer 00= HP M=Medium D=460/3/60 M=Beacon II 0* = -/2 HP E=Extra Low G=230//60 S= Beacon II 02*=2 HP X = Med./Low 03*= 3 HP 04*= 4 HP 05* = 5 HP 060= 6HP Model BH, BS, BZ Motor Motor Motor Head For For Fan Mount Pressure Front Unit Size Compr 230V Unit 460V Unit Blade Outdoor Indoor Valve Grill 005 to 04 All *253090S() *253090S() () () () All *253090S(2) *253090S(2) (2) (2) (2) to 020 Herm/Semi *253090S(2) *253090S(2) (2) (2) (2) Scroll *253090S(2) *253090S(2) (2) (2) (2) All *253090S(2) *253090S(2) (2) (2) (2) Hermetic *253090S(2) *253090S(2) (2) (2) (2) Scroll *253090S(2) *253090S(2) (2) (2) (2) Semi *253090S(2) *253090S(2) (2) (2) (2) Herm/Semi *253090S(2) *253090S(2) (2) (2) (2) Hermetic S() () 77356() () () M6 Scroll S() () 77356() () () L6 Scroll *253090S(2) *253090S(2) (2) (2) (2) H2,M2,M6 Semi () () 77356() () () L2,L6,E6 Semi *253090S(2) *253090S(2) (2) (2) (2) Hermetic *253090S(2) *253090S(2) (2) (2) (2) Hermetic () () 77356() () () M6 Scroll () () 77356() () () L6 Scroll *253090S(2) *253090S(2) (2) (2) (2) All () () 77356() () () M6 Scroll () () 77356() () () L6 Scroll () () 77356() () () to 060 All () () 77356() () () *Motor includes capacitor Motor Part No Use Capacitor Part No. 5779G Motor Part No Use Capacitor Part No. 5599M Note: To use on 460V - must wire thru transformer Optional Variable Speed Controller for Size 030D, X, H or M, 032, 035M, 040 to Controller and Sensor (Part No ) Optional Fan Cycle Switch for Size 05 to 030L - Pressure (Part No. 2890), Temperature (Part No. 552R ) Low Pressure Switch Dual High Pressure Switch Compressor Timers Fixed Fixed Pressure Fixed Fixed Phase 3 Phase Unit Size Adjustable Outdoor Indoor Switch Outdoor Indoor Contactor Contactor Paragon Grasslin Servicemate 005 to 035 R ; to Notes:. Excel beige began in 2/28/ leg kit (shipped loose) T stat disch. line scroll - Part No

25 BFH Fluid Cooler BFH Motor Fan Fan Model Part No. Blade Guard Single Row Of Fans S S S Bohn Double Row Of Fans S S S S Motor mounts not applicable - mounted on motor rails 25

26 BLH/BBH Condensing Units Bohn Nomenclature Example: BL H 0500 D 7 3 Nominal Horsepower Application Range Refrigerant Electrical Characteristics BL = Limitizer H = Horizontal 0300 = 3 HP 0750 = 7.5 HP L = Low (0ºF to -40ºF Suction) 2 = HCFC-22 3 = /60/3 BB = Bohnmizer Air Discharge 0400 = 4 HP 075 = 7.5 HP D = High/Medium (30ºF to -0ºF Suction) 6 = HFC-404A or HFC = 460/60/ = 5 HP 0800 = 7.5 HP M = Medium (30ºF to -0ºF Suction) 7 = HCFD-22 or CFC = 575/3 050 = 5 HP 0900 = 9 HP 9 = 230/60/ 0600 = 6 HP 000 = 0 HP 060 = 6 HP Part Description Part No. Motor /3 HP 230V 075RPM /2DIA CCWSE S Motor /3 HP 208/230/60/ PSC RPM 200 CCWSE Motor /3 HP // RPM CCWSE S Motor /2 HP 460V 075RPM /2DIA CCWSE S Motor /2 HP 575V 075RPM /2DIA CCWSE Fan Blade 22in CW 26D /2B Demand Cooling Control, 2D 240V Demand Cooling Control, 3D 240V Low Pressure Control - adjustable High Pressure Control Timer (845-20) Paragon Timer Grasslin Transformer, 460V/230V R Transformer, 575V/230V Crankcase Heater Compressor Contactor 25A, 3 Pole Contactor 40A 3P 24V -open Compressor Contactor 40A, 3 Pole Compressor Contactor 50A, 3 Pole Auxilary Contacts, Contactor Head Pressure Valve, OROA Head Pressure Valve, OROA Head Pressure Valve, OROI Head Pressure Valve, ORD Pressure Control Pressure Pressure Control R502/

27 BRI/BDI Nomenclature Example: B R I 0600 L6 C B = Bohn R = Reed I = Indoor 007* = 0.75 HP 050* = 5 HP L2 = Low (0ºF to -40ºF Suction) HCC-22 B = 208/230/60/ D = Discus 00* = HP 060* = 6 HP L6 = Low (0ºF to -40ºF Suction) C = 208/230/60/3 05* =.5 HP 075* = 7.5 HP HFC-440A/HFC-507/HCFC-22 D = 460/60/3 050* = 2 HP 080* = 7.5 HP M2 = Medium (35ºF to 0ºF) HCFC-22 E = 575/60/3 030* = 3 HP 00* = 0 HP M6 = Medium (30ºF to -0ºF) G = 230/60/ 040* = 4 HP HFC-404A/HFC-507 H2 = High/Medium (40ºF to 0ºF) HCFC-22 *HP Suffix H4 = High/Medium (40ºF to 0ºF) HFC-34A Bohn Motor/Fan Blade/Motor Mount Part No. Description S Motor, /3H 230V 075RPM /2DIA CW S Motor, /2H 460V 075RPM /2DIA CW Motor, /2H 575V 075RPM /2DIA CW Fan Blade 22in CW 26D /2B Motor Mount Contactors A 3P V A V A 600V NEMA Rated A 600V NEMA Rated R A 230V 2 Pole Controls Low Pressure Adjustable Dual Pressure Cont Man {20in -00/00-425} High Pressure Control 400#C.O. W/CONN Oil Failure Switch Sentronic Control with sensor R Disc Switch 30A -For 230V Units R Disc Switch 30A -For 460V Units R Disconnect Switch 60A Phase Monitor 208/240V Phase Monitor 460V Timer Compressor Lockout Timer V 40A SPDT Paragon Grasslin Servicemate Relay DPDT 230VAC Time Delay Relay 230V Thermostat {Open: 75ºF, Close: 40ºF} Terminal Block P LN 2/0-2 Load 4/P 4 Transformer R VA SL300QP Circuit Breaker A 2P 240V A 2P 240V A 2P 240V A 2P 240V A 2P 240V A 3P 240V A 3P 240V A 3P 240V Pressure Control Options Part No. Description /8 LAC4-DS 00/80 HPC (0075 thru 0202) /8 ODF 80# HD Pressure Control /8 00# HD Pressure Control /8 00/225 Adjustable HPC Valve Pressure Relief Valve Pressure Differential Valve Heater Ext Crankcase Heater 230V 65W Crankcase Heater Alum Foil Heater W For Heated Receiver Fuses A 600V CLASS CC A 600V CLASS CC A 600V CLASS CC A 600V CLASS CC A 600V CLASS CC A 600V CLASS CC A 250V CLASS RK A 600V CLASS RK A 250V CLASS RK A 600V CLASS RK A 250V CLASS RK A 600V CLASS RK A 250V CLASS RK A 250V CLASS RK A 250V CLASS RK A 250V CLASS RK A 250V CLASS RK5 Fuse Blocks A 600V 2P MDGT A 600V 3P MDGT Circuit Breaker A 3P 240V A 3P 240V A 2P 480V A 2P 480V A 3P 480V A 3P 480V A 3P 480V 27

28 BRI/BDI Continued Bohn Nomenclature Example: B R I 50* L6 C B = Bohn R = Reed I = Indoor 50* = 5 HP 250* = 25 HP L2 = Low (0ºF to -40ºF Suction) HCC-22 B = 208/230/60/ D = Discus 200* = 20 HP 270* = 27 HP L6 = Low (0ºF to -40ºF Suction) C = 208/230/60/3 220* = 22 HP 300* = 30 HP HFC-440A/HFC-507/HCFC-22 D = 460/60/3 *HP Suffix M2 = Medium (35ºF to 0ºF) HCFC-22 E = 575/60/3 M6 = Medium (30ºF to -0ºF) G = 230/60/ HFC-404A/HFC-507 H2 = High/Medium (40ºF to 0ºF) HCFC-22 H4 = High/Medium (40ºF to 0ºF) HFC-34A Motor/Fan Blade/Motor Mount Part No. Description R S Motor 3/4H 230V 075RPM 5/8DIA CCW R S Motor 3/4H 460V 075RPM 5/8DIA CCW R Blade 24in CCW 28DEG 5/8B Fan Motor Mount {Indoor} Back-24in & Guard Fan Motor Mount {Outdoor} Contactor A 3P V Contactor A 3P V Contactor A V Contactor CONT 27A 600V NEMA Rated CONT 45A 600V NEMA Rated R CONT 2 POLE 20A 230V Controls Oil Failure Switch Sentronic Control w/sensor Disc Switch 200A 3P 240V Disc Switch 60A 3P 600V Disc Switch 00A 3P 600V Mon Phase 208/240V Mon Phase 460V Timer Compressor Lockout Timer V 40A SPDT TI-TT Timer Paragon Grasslin Servicemate Relay V COIL DPDT Relay 2 Pole 30A DPDT Relay DPDT 24V Coil Time Delay Relay (On Beacon II Units) Time Delay Relay 230V Freezer stat P29-NC3 5738B Thermostat Terminal Block P LN 2/0-2 Load 4/P 4 Circuit Breaker A 2P 240V A 2P 480V A 3P 240V A 2P 240V A 3P 240V A 3P 480V (Siemens) A 3P 240V Pressure Control Options Adjustable Low Pressure SW./P70AB-D Control High Pressure PSIG Control High Pressure 400# Dual Pressure Cont Man {20in-00/00-425} High Pressure Control 400#C.O.W/CONN High Pressure Control Pressure Control -Fan Cycling Pressure Differential Valve Temperature Control -Fan Cycling Heater Crankcase 5737B Heater; 230V Tubular 00 WATT (REC R) Fuses A 600V CLASS CC A 250V CLASS RK A 250V CLASS RK A 600V CLASS CC A 600V CLASS CC A 600V CLASS CC A 600V CLASS CC A 600V CLASS CC A 600V CLASS CC A 600V CLASS RK A 600V CLASS CC A 600V CLASS RK A 600V CLASS RK5 Fuse Blocks A 600V 2P MDGT A 600V 3P MDGT Transformers R V/460V Primary Rated 300VA /2KVA 480/240P Circuit Breaker A 3P 240V A 3P 480V (Siemens) A 2P 480V A 3P 240V A 3P 240V A 3P 480V (Siemens) A 3P 240V 28

29 BMA/E/G/L/F Bohn Medium Profile Unit Cooler Nomenclature Example: BM A 30 B A Fins Per Inch/Defrost Voltage Vintage Bohn Medium Profile Unit Cooler A = 6 FPI Air Defrost Capacity x 00 A = 5//60 N = 0//50 E = 6 FPI Electric Defrost B = 208/230//60 Q = 220//50 L = 4 FPI Electric Defrost C = 208/230/3/60 R = 380//50 G = 6 FPI Hot Gas Defrost D = 460/3/60 V = 380/3/50 F = 4 FPI Hot Gas Defrost M = 460//60 Bohn Motor/Fan Blade/Guards Part No. Description 5020-SS Motor 5V 5020-TS Motor V 4567-T Motor V Totally Enclosed Motor 460V Special Low Temperature V Special Low Temperature 460V 5599-M Run Capacitor 593-H Motor 575V 5064-E Motor Mount 530-C Fan Blade 4339-X Fan Guard Molded w/ Logo 5063-E Fan Guard Beige Wire Miscellaneous Part No. Description 43-Y Room T stat 5709-L Defrost term. and fan delay T stat sealed bimetal type 5708-L Heater limit T stat Thread repair kit (molded fan guard mounting holes) () Kit per guard Note: Call Factory for hot gas Defrost components not listed. Drain Pan Defrost Heater (One employed per unit) BME, BMF, BMG, BML Part No. Description Voltage Color Code Fan Unit, 530W Fan Unit, 950W Fan Unit, 350W V Back Fan Unit, 800W Fan Unit, 2000W Fan Unit, 530W Fan Unit, 950W Fan Unit, 350W 460V Red Fan Unit, 800W Fan Unit, 2000W Fan Unit, 950W Fan Unit, 350W 5V Back, White Fan Unit, 800W Coil Defrost Heaters (Four employed per unit) BME, BML Part No. Description Fan Unit, 550W Fan Unit, 00W Fan Unit, 600W Fan Unit, 200W Fan Unit, 2400W Heater Clip Note: Drain pan heaters are voltage specific Model Size No. of Fans Model size No. of Fans BMA30 BMG90 2 BMA55 BMG290 2 BMA245 2 BMG30 3 BMA300 2 BMG390 3 BMA365 3 BMG430 4 BMA450 3 BMG520 4 BMA50 4 BMA600 4 BMA70 5 BME0 BMF65 2 BME40 BMF220 2 BME90 2 BMF250 3 BME260 2 BMF330 3 BME30 3 BMF370 4 BME290 3 BMF440 4 BME430 4 BME520 4 BME FPI BML00 BML65 2 BML220 2 BML250 3 BML330 3 BML370 4 BML440 4 BML530 5 Cabinet Components Part No. Description # Fans Drain Pan* Drain Pan* Drain Pan* Drain Pan* Drain Pan* Header Side Panel Electrical Side Panel Header Connection Panel * includes provisions to mount drain pan heater. DOES NOT INCLUDE Drain Fitting No

30 Beacon I System Replacement Parts Bohn {EX: ADT04BBCN6J} Part Description Part No. Temperature Sensor Transformer, 208/ volt-40 VA Transformer, 208/ volt-75va Relay for Condenser Fan or Crankcase Heater Contactor for Compressor 40A with 24 volt Coil Control Board for Electric Defrost Control Board for Air Defrost Terminal Block Low Pressure Switch Time Delay Relay Electric Expansion Valve: ESV - 24 Volt Call Factory ESV 2-24 Volt Call Factory ESV 4-24 Volt Uni-polar Valves Call Factory ESV 6-24 Volt Call Factory ESV 8-24 Volt Call Factory ESV Volt - Bi-polar Valve Expansion Valve Molded Connector Optional Pump-Down Switch Beacon II Smart Controller Optional Smart Controller Software Package Obsolete Bi-polar Adapter Board (Only Used w/ Exp.Valve Resistor Kit) Retrofit Kit Uni-polar Valve to Bi-polar Valve Beacon II System Replacement Parts Began 0/0 {EX: ADT04BB2NK} 30 Part Description Part No. Heater High Limit 5708L Terminal Block on Air Defrost 5857A Temperature Sensor Pressure Transducer Harness Expansion Valve Harness (Bi-polar valves) Expansion Valve Harness (Uni-polar valves) Transformer 20V/24V Transformer V/24V Transformer 460V/24V Transformer 575V/24V Beacon II Board Pressure Transducer Expansion Valve - ESB - 3/8 x 3/8 Conn Expansion Valve - ESB 4-3/8 x 3/8 Conn Expansion Valve - ESB 0-3/8 x 3/8 Conn Expansion Valve - ESB 0 - /2 x /2 Conn Expansion Valve - ESB 5-7/8 x 3/8 Conn Expansion Valve - ESB 20-7/8 x 3/8 Conn Smart II Software Package Smart Controller II Package MCD -BCN II w/ K vintage

INTERLINK PARTS RECOMMENDED STOCKING LIST 2018

INTERLINK PARTS RECOMMENDED STOCKING LIST 2018 INTERLINK PARTS RECOMMENDED STOCKING LIST 2018 BLADES 2291030 BLADE 10 DIA 31 DEG 5/16 CCW HF 5B 2291031 BLADE 10 DIA 31 DEG 5/16 CW HB 2292625 BLADE 26 DIA 28 DEG 1/2B CW HF 4BL 2293030 FAN 30 DIA 30

More information

Low Profile Unit Coolers

Low Profile Unit Coolers BN-LOPTB AUGUST 2018 Replaces BN-LOPTB APRIL 2018 Low Profile Unit Coolers Technical Guide s ADT LET/LLE HGT Table of Contents Nomenclature... 2 Features & Benefits... 3 Performance Data & Specifications...

More information

Center Mount Unit Coolers

Center Mount Unit Coolers CC-CMTB JULY 2017 Replaces CC-CMTB JULY 2016 Center Mount Unit Coolers Technical Guide s TLC Air Defrost TLF Electric Defrost Table of Contents Nomenclature...2 Features & Benefits...3 Performance Data...4

More information

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost. LK-LVTB May 2008 Replaces LW-03, February 2003 FPO Low Velocity Center Mount Unit Cooler Technical Guide s LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost www.larkinproducts.com Table of

More information

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May, CH-LOPTB May, 2008 Replaces CH-B-15B, March 2004y 2007 LOW PROFILE UNIT COOLER Technical Guide s RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost www.chandlerref.com Table of Contents Nomenclature...2

More information

Low Profile Unit Coolers

Low Profile Unit Coolers CH-LOPTB MAR 2015 Replaces CH-LOPTB JAN 2015 Low Profile Unit Coolers Technical Guide s RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost Table of Contents Nomenclature 2 Features & Benefits

More information

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00 BEHA006M8-HS2C EH-LINE HERMETIC CONDENSING UNITS-AIR ITEM # : MODEL FEATURES Copper tubing secured with cushion Outdoor weather-resistant housing Weatherproof electrical control box with clamps made from

More information

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide BN-HGDTB June 2017 Replaces BN-HGDTB, March 2011 Mohave Technical Guide Table of Contents Overview... 2 System Features... 3 Condensing Unit... 4-18 Mohave Hot Gas Defrost Quick Reference... 5 AWEF Ratings...11

More information

Low Flow Unit Coolers

Low Flow Unit Coolers BN-LFTB October 2016 Replaces BN-LFTB APR 2015 Low Flow Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost Table of Contents Nomenclature...2 Features & Benefits...3

More information

commercial refrigeration products

commercial refrigeration products commercial refrigeration products Evaporators Condensing Units Condensers Air Handlers Fluid Coolers Coils NOTHING BEATS A BALLY Evaporators EC MOTORS Available Half Round Low velocity Two-way low profile

More information

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5 ` RLP 1-2019C Prices effective January 1, 2019. Supersedes all earlier versions LIST PRICES All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed

More information

horizontal air discharge outdoor discus condensing unit

horizontal air discharge outdoor discus condensing unit CC-HADTB March 2007 (Replaces CC-B-48D, 10/04) CLIMATE CONTROL horizontal air discharge outdoor discus condensing unit Technical Guide CDH Standard & Optional Features CDH Outdoor Discus Condensing Units,

More information

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost. bn-lftb May 2008 Replaces 412.0, May 2004 Lo-Aire Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost www.thecoldstandard.com Table of Contents Nomenclature...2 Features

More information

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018 ` RLP 4-2018 R1 Supersedes all earlier versions LIST PRICES April, 2018 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single orders with

More information

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

LIST PRICES SEE THE BACK COVER FOR CONDITIONS OF SALE AND WARRANTY BULLETIN KLP 4-2018 R1 Supersedes All KRAMER Price Lists Published Prior To April 2018 April, 2018 LIST PRICES Add appropriate expansion valve price(s) from page 13 of this price sheet when unit coolers

More information

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5 ` RLP 2-2017 Supersedes RLP 8-2016 and all previous versions LIST PRICES February, 2017 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single

More information

Page ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18

Page ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18 ` RLP 7-2018A Supersedes all earlier versions LIST PRICES Prices effective 7/2/18 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single

More information

High Profile Evaporator

High Profile Evaporator PRODUCT DATA & INSTALLATION Bulletin K30-KHPA-PDI-5 Part # 1081585 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: High Profile Evaporator High & Medium Temperature

More information

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax WIBR SERIES Unit Coolers - Technical Catalog 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Features/Applications Century Refrigeration s WIBR Series Unit

More information

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017 Replacement s List 055208000 Revision E 08/207 McQuay Incremental MQS 007-05 Vintages A 02-05 Vintage B Last Manufactured: 993 To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

RLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES

RLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES ` RLP 1-2019 Prices effective January 1, 2019. Supersedes all earlier versions LIST PRICES All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-AAX-1215A All-Temp 2 B LOW PROFILE UNIT COOLER Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-AAX-0516A All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost

More information

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

LIST PRICES SEE THE BACK COVER FOR CONDITIONS OF SALE AND WARRANTY BULLETIN KLP 7-2018A Supersedes All KRAMER Price Lists Published Prior To July 2018 July, 2018 LIST PRICES Prices effective 7/2/18 Add appropriate expansion valve price(s) from page 13 of this price sheet

More information

KTL Two-Way Low Profile Evaporators

KTL Two-Way Low Profile Evaporators PRODUCT DATA & INSTALLATION Bulletin K30--PDI-16 Part # 87830 PRODUCT SUPPORT web: k-rp.com/ktl email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: Two-Way Low Profile Evaporators High, Medium and Low

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

TLV Low Velocity Evaporators

TLV Low Velocity Evaporators PRODUCT DATA & INSTALLATION Bulletin T30-TLV-PDI-27 Part # 1073478 PRODUCT SUPPORT web: t-rp.com/tlv email: evaps@t-rp.com call: 1-844-893-3222 x520 scan: TLV Low Velocity Evaporators High Temperature

More information

Super-Flo Low Profile Unit Cooler

Super-Flo Low Profile Unit Cooler Publication No. WT-SAX-0516A Low Profile Unit Cooler Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost 3,600

More information

Compak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03)

Compak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03) Bulletin LC-03A August 2004 (Replaces LC-03 3/03) Compak Unit Coolers LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost 3,500 to 27,000 BTU/H Front access to refrigeration components. Now

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016 Replacement Parts List No. 057117300 Revision D 08/2016 AAF Water Source Heat Pump Ceiling Mounted CCW 019-060 Vintage E Last Manufactured: 1999 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Parts Manual Frigoglass/Universal Nolin/Beverage Air - MT27

Parts Manual Frigoglass/Universal Nolin/Beverage Air - MT27 Parts Manual Frigoglass/Universal Nolin/Beverage Air - MT7 Page of 0 0079 00696 PANEL,SIDE,MT7//9/7 LEFT, 06 0079 00697 PANEL,SIDE,MT7//9/7,RIGHT, PRE-PAINTED PRE-PAINTED 0790 BPS-6C0007A 00086 GRILLE,KIT,REPLACEMENT,MT7,BLACK.0

More information

Slim Contour Unit Cooler

Slim Contour Unit Cooler Slim Contour Unit Cooler with Modular Cassette Design ULA/ULE Models LK-SLIM-TB l APRIL 2018 Replaces LK-SLIM-TB l SEPT 2016 ULA/ULE - Slim Contour Unit Cooler Maximized Storage, Minimized Energy The Slim

More information

Kramersaver Air Cooled Condensing Units

Kramersaver Air Cooled Condensing Units Catalog KM-KSX-0613A Kramersaver Series Kramersaver Air Cooled Condensing Units Models C & KS 4 through 70 HP Kramer C and KS model condensing units are available in 4 to 70 HP. While the basic C model

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION Service Facts Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION 4TTB6-SF-3 UNIT CONTAINS R-410A REFRIGERANT R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS REQUIRED.

More information

Condensing Units w/ Screw Compressors

Condensing Units w/ Screw Compressors w/ Compressors Overview Increased Reliability Fewer moving parts result in improved durability Semi-hermetic motor design eliminates shaft seal and coupling concerns Integral oil system provides improved

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING Service Facts Split System Cooling 4TTR6024A1000B 4TTR6024A1000B 208/230/1/60 18 20 CLIMATUFF - SCROLL 1-2 208/230/1/60 13.0-52 PROPELLER 27.6-1 DIRECT - 1 3200 1-1/8 835 208/230/1/60 0.74 SPINE FIN 1-24

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING Service Facts Split System Cooling 4TTR6048A1000A 4TTR6048A1000A 208/230/1/60 28 45 CLIMATUFF - SCROLL 1-2 208/230/1/60 21.2-104 PROPELLER 27.6-1 DIRECT - 1 4260 1-1/5 825 208/230/1/60 1.0 SPINE FIN 1-24

More information

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS Publication No. CZ-CFH-0617A Replaces document CZ-CFH-0117A Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 1/2 TO 6 HP The Next Generation of Uni-Paks are Here! ColdZone s

More information

Reach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June

Reach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June LK-RITB June 2009 Replaces LK-RITB, January 2004 FPO Reach-In Unit Coolers Technical Guide s TA TL C VA BBM BBL KMK RAMK BTO U www.larkinproducts.com Table of Contents TA Thin Profile Air Defrost... 3

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

KCS-Line Air Cooled Condensers

KCS-Line Air Cooled Condensers PRODUCT DATA & INSTALLATION Bulletin K50-KCS-PDI-5 Part # 1085695 PRODUCT SUPPORT web: k-rp.com/kcs email: acc-fc@k-rp.com call: 1-844-893-3222 x526 scan: KCS-Line Air Cooled Condensers R407A R407C R448A

More information

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 055236000 Revision B 06/2015 McQuay Ceiling Concealed Horizontal Water Source Heat Pump CCH, CCG, CCW 048, 060 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts

More information

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24 Refrigeration / Air Conditioning Systems Circuit Drawings Nominal Student Hours: Student Resource Package No: NR 24 24 Hours. Delivery: Recognition of Prior Learning: Package Purpose: Suggested Resources:

More information

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8 Service Facts Split System Cooling 4TTB3048D1000B, 4TTB3060D1000B CAUTION IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain

More information

36,000-62,000 BTUH Nominal Capacity

36,000-62,000 BTUH Nominal Capacity 36,000-62,000 BTUH Nominal Capacity STANDARD EQUIPMENT 2TEE3F62A, 4TEE3F62B VARIABLE SPEED AIR HANDLER Ships horizontal - converts to vertical by standing on end. Six-way convertibility-horizontal (left

More information

Installation and Operation Manual

Installation and Operation Manual Beacon II Refrigeration Systems H-IM-79G April 2018 Part No. 25001401 Replaces H-IM-79F (08/17) Installation and Operation Manual Table of Contents Beacon II Board Layout... 2 Installation Tips... 3 Refrigerant

More information

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8 Service Facts Split System Cooling 4TTR3060D1000A CAUTION IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this

More information

KTL Two-Way Low Profile Unit Coolers

KTL Two-Way Low Profile Unit Coolers PRODUCT DATA & INSTALLATION Bulletin K30-KTL-PDI-2 1087830 KTL Two-Way Low Profile Unit Coolers High, Medium and Low Temperature Applications -10 F (-23.3 C) and above Air or Electric Defrost Electrical

More information

BTL Two-Way Low Profile Evaporators

BTL Two-Way Low Profile Evaporators PRODUCT DATA & INSTALLATION Bulletin B30-BTL-PDI-3 1087832 Latest product updates and further information at w ww.ballyrefboxes.com BTL Two-Way Low Profile Evaporators High, Medium and Low Temperature

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS T CLASS TPA Series HEAT PUMPS 7.5 TO 10 TONS 506148 01 12/08 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT The Clean Air Act of 1990 bans the intentional

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS T CLASS TPA Series 7.5 AND 10 TON HEAT PUMPS 7.5 TO 10 TONS 506148 01 10/2011 Supersedes 06/11 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT The Clean

More information

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN Service Facts Split System Cooling 4TTB3030D1000A IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit. Please

More information

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT Service Facts Split System Cooling 4TTR6036B1000A IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit. Please

More information

SOS Multi-Horsepower Outdoor Condenser Fan Motor

SOS Multi-Horsepower Outdoor Condenser Fan Motor SOS Multi-Horsepower Outdoor Condenser Fan Motor Slim Stack # 03458 Wizard fits many 1/3 HP installations that will not accept competitor s motors. Wide range motor that will run at any fan load from 1/6

More information

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A900-22007), 120/208/240/1/60, R404A, LT/MT APPS Introduction The superheat controller is designed

More information

WCH5**4. Product Specifications

WCH5**4. Product Specifications HEAT PUMP HIGH EFFICIENCY 15 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 208 / 230 Volt, 1- phase, 60 Hz This product has been designed and manufactured to meet ENERGY

More information

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES Service Facts Split System Cooling 4TTB18E1000A, 4TTB24E1000A 4TTBD1000B, 4TTB36D1000B 4TTB3-SF-1B CAUTION UNIT CONTAINS R-410A REFRIGERANT R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE

More information

CABINET PARTS For Model: ED5GTGXNQ14, ED5GTGXNB14 (White) (Black)

CABINET PARTS For Model: ED5GTGXNQ14, ED5GTGXNB14 (White) (Black) CABINET PARTS REFRIGERATOR 07 07 Litho In U.S.A. (mat) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts 2315254 Use & Care Guide 2255373 Service & Wiring Sheet 2318639 Energy Guide 628370 Modular Icemaker

More information

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature

More information

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) INDEX UNIVERSAL ELECTRONIC CONTACTOR UPGRADE SURESWITCH 79 Description Model(s) Page(s) SureSwitch... 49P11-843... 79 CONTACTORS 80 82 Description Model(s) Page(s) 1 Pole... 94-388 Thru 94-395... 80 2

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

Installation, Start-Up and Service Instructions

Installation, Start-Up and Service Instructions Installation, Start-Up and Service Instructions GEMINI 38ARZ007-012, 38ARS008-012 38ARD012-024, 38AKS014-024 Air-Cooled Condensing Units 50/60 Hz CONTENTS Page SAFETY CONSIDERATIONS...1 INSTALLATION...

More information

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions. MS Series UNIT COOLERS Technical Bulletin: MSUC_005_032 Products that provide lasting solutions. Medium Profile Units for Medium Size Walk-In Coolers and Freezers Access Panel Hinged panel cover provides

More information

(EE1500, EE2000, EE2500, EE3000)

(EE1500, EE2000, EE2500, EE3000) EE-Ti (EE1500, EE2000, EE2500, EE3000) Heat Pump (Mfg. 2010 Present) 15 26 3 11 12 1 BLUE WIRE RED WIRE YELLOW WIRE ORANGE WIRE These pressure switches are installed in the refrigerant line near the compressor

More information

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/ Service Facts Split System Heat Pump 4TWB4024E1000A IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit.

More information

Air Cooled Scroll Compressor Condensing Unit

Air Cooled Scroll Compressor Condensing Unit Replacement Parts List No. 70000900 Rev. B 2/08 Air Cooled Scroll Compressor Condensing Unit ACZ Sizes: 00-039 Vintage: B R22, R407C Contents Contents... 2 Parts List Revision History... 3 Nomenclature

More information

IOM 410. Installation Operation Maintenance Information. UNIT COOLERS Super-Flo (SD Models) Easy-Flo (EF Models) Table of Contents

IOM 410. Installation Operation Maintenance Information. UNIT COOLERS Super-Flo (SD Models) Easy-Flo (EF Models) Table of Contents IOM 410 Installation Operation Maintenance Information UNIT COOLERS Super-Flo (SD Models) Easy-Flo (EF Models) Air, Electric & Hot Gas Defrost Table of Contents Inspection..........................................

More information

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991 Replacement Parts List No. 055203500 Revision G 05/206 McQuay Climate Control Singer Incremental ES, RS, S 06, 09,, 4 Vintage B Last Manufactured: 99 To find your Daikin Applied parts distributor, call

More information

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES Service Facts Split System Heat Pump 4A6H5049E1000B IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit.

More information

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND REFRIGERANT NH4H4 Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

CABINET PARTS For Models: ED5LHEXTD00 (Universal Silver)

CABINET PARTS For Models: ED5LHEXTD00 (Universal Silver) CABINET PARTS REFRIGERATOR 06 07 Litho In U.S.A. (mat) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts 2309541 Use & Care Guide 2311815 Service & Wiring Sheet 2325842 Energy Label 2261037 Instruction

More information

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT Service Facts Split System Heat Pump 4A6H5042G1000A CAUTION IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this

More information

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional Now available with optional ECM Motors High Efficiency / High Reliability Low rofile Unit Cooler ublication No. 100.14 January, 2008 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000

More information

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994 Replacement Parts List No. 05708900 Revision C 06/205 McQuay Incremental Packaged Terminal Air Conditioner MQT 06-4 Vintage B Last Manufactured: 994 To find your Daikin Applied parts distributor, call

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons Product Data 07DA, DB 07EA, EB, ED Condensing Units 3 to 40 Nominal Tons 06D, 06E Compressors An excellent choice for your built-up system Carrier 07 Series condensing units built for the engineer who

More information

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw) Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series

More information

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS TC SERIES OPTIONS TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15,, 5 AIR COOLED PACKAGED WATER CHILLERS CONTENTS EQUIPMENT AND COMPONENT DETAILS PERFORMANCE AND TECHNICAL DATA SCHEMATIC FLOW & SYSTEM

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

Installation and Operation Manual

Installation and Operation Manual Beacon II Refrigeration Systems H-IM-79F April 2017 Part No. 25001401 Replaces H-IM-79E (6/11) Installation and Operation Manual Table of Contents Beacon II Board Layout... 2 Installation Tips... 3 Refrigerant

More information

CABINET PARTS For Models: ASD2522WRS07 (Stainless)

CABINET PARTS For Models: ASD2522WRS07 (Stainless) CABINET PARTS REFRIGERATOR 9 11 Litho In U.S.A. (wam) (psw) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts W10321484 Use & Care Guide W10275776 Service & Wiring Sheet W10234042 Energy Guide 628370

More information

CABINET PARTS REFRIGERATOR. For Models: ED5VHGXMQ00, ED5VHGXMT00, ED5VHGXMB00 (White) (Biscuit) (Black) 8 03 Litho In U.S.A. (kdj)

CABINET PARTS REFRIGERATOR. For Models: ED5VHGXMQ00, ED5VHGXMT00, ED5VHGXMB00 (White) (Biscuit) (Black) 8 03 Litho In U.S.A. (kdj) CABINET PARTS REFRIGERATOR 8 03 Litho In U.S.A. (kdj) 1 Part No. Rev. C CABINET PARTS 1 LIT2220692 Use & Care Guide LIT2255377 Service & Wiring Sheet LIT2260931 Energy Label LIT628370 Modular Icemaker

More information

Parts Manual Frigoglass/Universal Nolin/Beverage Air - MT49

Parts Manual Frigoglass/Universal Nolin/Beverage Air - MT49 Parts Manual Frigoglass/Universal Nolin/Beverage Air - MT9 Page of NR 0 0079 00696 PANEL,SIDE,MT7//9/7 LEFT, NR 06 0079 00697 PANEL,SIDE,MT7//9/7,RIGHT, 090 998060 000898 GRILLE, MT, BTM 6 9999070 008

More information

Packaged refrigeration system Technical Guide

Packaged refrigeration system Technical Guide bn-ptmtb January 2008 Replaces bn-protb, 8/07 PRO 3 Top mount Packaged refrigeration system Technical Guide Model PTN and PTT For Indoor and Outdoor Applications Table of Contents Nomenclature...2 Features

More information

FFTR1514TW.jpg DRFFTR1514TB0.wmf CAWWTR1611SW0.wmf SHFFTR1614RW0.wmf SYFFTR1514RB1.wmf W eps S eps

FFTR1514TW.jpg DRFFTR1514TB0.wmf CAWWTR1611SW0.wmf SHFFTR1614RW0.wmf SYFFTR1514RB1.wmf W eps S eps Product No. B0 W0 Series R134a R134a Color black white Volts 115 115 Wiring Diagram 241582401 241582401 Owner's Guide A04555602 A04555602 Market North America North America Energy Guide A01298702 A10298702

More information

REPAIR PARTS. GSZ14 R-410A Remote Heat Pumps GSZ140181AA GSZ140241AA GSZ140301AA GSZ140361AA GSZ140421AA GSZ140481AA GSZ140601AA

REPAIR PARTS. GSZ14 R-410A Remote Heat Pumps GSZ140181AA GSZ140241AA GSZ140301AA GSZ140361AA GSZ140421AA GSZ140481AA GSZ140601AA GSZ14 R-410A Remote Heat Pumps GSZ140181AA GSZ140241AA GSZ140301AA GSZ140361AA GSZ140421AA GSZ140481AA GSZ140601AA REPAIR PARTS This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing

More information

EXPLODED VIEWS & PARTS LISTS

EXPLODED VIEWS & PARTS LISTS 542 DOOR VIEW Ref. Part No. Description Ref. Part No. Description 1 6200720 Screw, #8-18 x 1/2 PH Truss HD 2 420040 Standard Handle End Cap Replacement Components 4200700 Extended Handle End Cap Replacement

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature......3 Dimensions...4 Airflow Data...5

More information

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions. SM/SV Series PRODUCT COOLERS Technical Bulletin: SMSV_005_040517 Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal

More information

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions. SM/SV Series PRODUCT COOLERS Technical Bulletin: SMSV_001_083115 Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal

More information

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... 3 Dimensions...

More information

CABINET PARTS REFRIGERATOR

CABINET PARTS REFRIGERATOR CABINET PARTS REFRIGERATOR 1 94 Litho In U.S.A. 1 Part No. CABINET PARTS 2 2152011 Front Roller (2) 3 489393 Screw, 4 981122 Roller (Rear) (2) 5 488454 Screw 6 2155013 Clip, Grille 7 489242 Screw 9 836196

More information

SMALL AIR COOLED CONDENSERS

SMALL AIR COOLED CONDENSERS Catalog KM-KDX-0816A Supersedes Catalog KM-KDS-1014A UNICON SMALL AIR COOLED CONDENSERS 2 Unicon Efficient and Reliable Kramer s Remote Air Cooled Condensers innovative design provides a wide array of

More information

CABINET PARTS For Models: ASD2522WRW03, ASD2522WRB03, ASD2522WRS03, ASD2522WRD03 (White) (Black) (Stainless) (Universal Silver)

CABINET PARTS For Models: ASD2522WRW03, ASD2522WRB03, ASD2522WRS03, ASD2522WRD03 (White) (Black) (Stainless) (Universal Silver) CABINET PARTS REFRIGERATOR 8 10 Litho In U.S.A. (jdc)(bay) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts W10237701 Use & Care Guide W10207987 Service & Wiring Sheet W10307453 Energy Guide 628370 Modular

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS T CLASS TSA Series 6 to 20 Ton AIR CONDITIONERS 6 20 TONS 506147 01 06/11 Supersedes 3/11 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT The Clean Air Act

More information

CABINET PARTS For Models: MSD2553WEW01, MSD2553WEB01, MSD2553WEM01 (White) (Black) (Stainless Steel)

CABINET PARTS For Models: MSD2553WEW01, MSD2553WEB01, MSD2553WEM01 (White) (Black) (Stainless Steel) CABINET PARTS Refrigerator 4 10 Printed In U.S.A. (jdc)(bay) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts W10210296 Energy Guide W10213163 Owner s Manual W10238215 Service & Wiring Sheet 2220407

More information