DOMESTIC HOT WATER TANK

Size: px
Start display at page:

Download "DOMESTIC HOT WATER TANK"

Transcription

1 Operating Manual UK DOMESTIC HOT WATER TANK SOLAR DOMESTIC HOT WATER TANK Accessories for heat pumps

2 Please read first This operating manual provides important information on handling the unit. It is an integral part of the product and must be stored so that it is accessible in the immediate vicinity of the unit. It must remain available throughout the entire service life of the unit. It must be handed over to subsequent owners or users of the unit. Read the operating manual before working on or operating the unit. This applies in particular to the chapter on safety. Always follow all instructions completely and without restrictions. It is possible that this operating manual may contain instructions that seem incomprehensible or unclear. In the event of any questions or if any details are unclear, contact the factory customer service department or the manufacturer's local partner. Since this operating manual was written for several different models of the unit, always comply with the parameters for the respective model. This operating manual is intended only for persons assigned to work on or with the unit. Treat all constituent parts confidentially. The information contained herein is protected by copyright. No part of this manual may be reproduced, transmitted, copied, stored in electronic data systems or translated into another language, either wholly or in part, without the express written permission of the manufacturer. Symbols The following symbols are used in the operating manual. They have the following meaning: Information for users. Information or instructions for qualified personnel. DANGER! Indicates a direct impending danger resulting in severe injuries or death. WARNING! Indicates a potentially dangerous situation that could result in serious injuries or death. CAUTION! Indicates a potentially dangerous situation that could result in medium or slight injuries. CAUTION! Indicates a potentially dangerous situation, which could result in property damage. NOTICE Emphasised information. Reference to other sections of the operating manual. Reference to other documents of the manufacturer. 2

3 Contents INFORMATION FOR USERS AND QUALIFIED PERSONNEL PLEASE READ FIRST...2 SYMBOLS...2 INTENDED USE...4 DISCLAIMER...4 SAFETY...4 CUSTOMER SERVICE...4 WARRANTY / GUARANTEE...4 MAINTENANCE OF THE UNIT...4 SCOPE OF DELIVERY...5 INFORMATION FOR QUALIFIED PERSONNEL INSTALLATION...5 Transport to installation location...6 Installation...6 INSTALLATION...6 Installation of the sensor for the heating and heat pump regulator...7 COMMISSIONING...7 INSULATION OF THE CONNECTIONS AND THE STORAGE TANK...7 DRAINING...7 TECHNICAL DATA WWS...8 WWS, SWWS...10 INSTALLATION PLANS DIMENSIONED DRAWINGS DIMENSIONED DRAWINGS...13 WWS DIMENSIONED DRAWINGS...14 WWS 202 / WWSB WWS 303, WWS 303.1, WWS WWS 806 WWS SWWS SWWS SWWS 806 SWWS CONNECTION INSTRUCTIONS Domestic hot water tank...20 Solar domestic hot water tank...21 EC DECLARATION OF CONFORMITY

4 Intended use The storage tank may be used only for the intended purpose. This means as a domestic hot water tank suitable for normal drinking water in conjunction with: Air/water heat pumps Brine/water heat pumps Water/water heat pumps WWS 121 is only allowed with WWB 20 CAUTION! The electrical conductivity of the domestic hot water must be > 100 µs/cm and must lie within the drinking water quality values. Safety The unit is safe to operate for its intended use. The construction and design of the unit conform to current state of the art standards, all relevant DIN/VDE regulations and all relevant safety regulations. Every person who performs work on the unit must have read and understood the operating manual prior to starting any work. This also applies if the respective person has already worked with such a unit or a similar unit or has been trained by the manufacturer. WARNING! Qualified trained personnel only (qualified heating, cooling system, refrigeration or refrigerant technician or electrician) may carry out work on the unit and its components. NOTE With solar domestic hot water tanks (SWWS) it is possible to connect solar systems. Disclaimer The manufacturer is not liable for losses resulting from any use of the unit which is not its intended use. The manufacturer's liability also expires: if work is carried out on the unit and its components contrary to the instructions in this operating manual. if work is improperly carried out on the unit and its components. if work is carried out on the unit which is not described in this operating manual, and this work has not been explicitly approved by the manufacturer in writing. if the unit or components in the unit have been altered, modified or removed without the explicit written consent of the manufacturer. Customer service For technical information please contact your local heating engineer or the manufacturer's local partner. "Customer service" overview in the heat pump operating manual. Warranty / Guarantee For warranty and guarantee conditions, please refer to the purchase documents. NOTE Please contact your dealer about all matters concerning warranties and guarantees. Maintenance of the unit The functional safety of the safety valve and the pressure reducer, if integrated in the system (to be provided on site) must be checked at regular intervals. We also recommend annual cleaning / servicing of the tank by a specialist firm. 4

5 CAUTION! Have the magnesium anode checked and if necessary renewed by the customer service for the first time after 2 years and then at appropriate intervals. Renew anode if protective current lower than 0.3 ma. After replacing the anode, re-install earthing cable between anode and storage tank jacket. NOTE Descale electric heating elements (if installed) annually, or at shorter intervals depending on the hardness of the water. Carry out a functional check at the same time. Disposal When withdrawing the old unit from service, comply with the relevant local laws, guidelines, directives andstandards concerning recovery, recycling and disposal. Scope of delivery Domestic hot water storage tank enamelled to DIN 4753 with smooth tube heat exchanger designed especially for heat pumps, integrated corrosion protection anode and 1 sensor for the heating and heat pump controller. Check the delivery for outwardly visible signs of damage Check to make sure that the delivery is complete. Report defects or incorrect deliveries immediately. Refer to the rating plate attached to the delivered storage tank to find out what type of storage tank it is. The abbreviations stand for the following: WWS = domestic hot water tank SWWS = solar domestic hot water tank (domestic hot water tank with ability to connect solar systems) Use of electric heating elements is only allowed up to 14 dh Typ WWS 121 WWS 202 WWS B 202 WWS 303 WWS EHZI 45 n.g. n.g. n.g. n.g. n.g. EHZI 45F n.g. Typ WWS WWS WWS WWS EHZI 45 n.g. EHZI 45F n.g n.g Typ SWWS SWWS SWWS SWWS EHZI 45 EHZI 45F n.g. n.g. : suitable combination, n.g. : not suitable For details of the quantity and positioning of the heating element sockets, refer to the dimensioned drawing of the respective tank. Installation Observe the following when performing all work: NOTE Always comply with the applicable local accident prevention regulations, statutory regulations, ordinances, guidelines and directives. CAUTION! The tank must be installed in a frostproof room, to prevent frost damage to the storage tank, pipe system and connections. NOTE Install the storage tank as close as possible to the heat generator, to keep the heat losses as low as possible. Ensure the shortest possible pipe lengths to the load. CAUTION! The floor or ground at the place of installation must be dry, firm and able to safely support the weight of the tank. ACCESSORIES CAUTION. Use only original accessories from the manufacturer of the unit. For the weight of the tank, please refer to the dimensioned drawing for the respective model. 5

6 TRANSPORT TO INSTALLATION LOCATION To avoid damage during transport, transport the storage tank (secured on the wooden pallet) to its final installation location using a lifting truck. WARNING! The unit can tip over when being removed from the wooden pallet and during transport with a hand truck or lift truck. This can result in personal injuries and damage. Take suitable precautions to prevent the tipping hazard. NOTE The storage tank is delivered fully insulated. Dispose of the transport and packaging materials properly and under ecological aspects. Plastic plugs for internal threads (Protect the threads and must be removed during installation. For connections which are not required, they must be replaced with pressure-resistant plugs): Plastic plug connecting piece Plastic caps for external threads (Protect the threads and must be removed during installation. For connections which are not required, they must be replaced with pressure-resistant caps): Plastic cap INSTALLATION When installing the tank, ensure sufficient clearance from walls and other objects to enable the connection pipes to be fitted. Installation NOTE. Always comply with the applicable local accident prevention regulations, statutory regulations, ordinances, guidelines and directives. connecting piece Plastic tube sleeves for conical external threads on drinking water connections of 3/4", 1" and 5/4" (Protect internally enamelled nozzles and may not be removed, but instead must remain in operation in the tank): Plastic sleeve CAUTION With our domestic-hot-water tanks, the following plastic protective components can be deployed on and in the connections: connecting piece NOTE. To level out pressure fluctuations or water hammer in the cold water network and to avoid unnecessary water loss, we recommend installation of a suitable expansion vessel with flow fittings. 6

7 CAUTION! Do not exceed the operating pressures specified on the rating plate. If necessary, install a pressure reducer. NOTE Close off any connections not required with appropriate plugs. NOTE In case of installation of the solar circuit with simultaneously installed electric heating element the maximum storage tank temperature must be set so that the safety temperature limiter (overheat cut-off device) does not trip. To this end, follow the separate operating instructions of the heating element and solar controller. For position of the connections, please refer to the dimensioned drawing for the respective model. CAUTION! Always integrate the tank in the system according to the connection instructions. Connection instructions from page 20. Use the safety valve according to the respective current standards, guidelines and directives and according to the maximum allowae operating pressures of the storage tank and components. The safety discharge of the safety valve must be discharged into the drain via a funnel-shaped odour trap according to the respective current standards, guidelines and directives! The discharge pipe connected to the safety valve must be installed with continuous downward gradient in a frost-free environment. Water can drip from the safety valve NOTE The function of the pressure relief device must be checked at regular intervals. INSTALLATION OF THE SENSOR FOR THE HEATING AND HEAT PUMP REGULATOR Depending on the unit model, you must install the sensor included in the scope of supply for the heating and heat pump controller on site in of the sensor pockets provided for this purpose. (In some models this sensor is installed in the factory). For item, see dimensioned drawing for respective model. Sensor connection: see heat pump operating manual. Domestic hot water temperature setting: s e e controller operating manual Commissioning Check whether the water supply is open and the tank is full Check the safety valve is working properly (and if applicable the pressure reducer) Test the safety valve (and if applicable the pressure reducer) for full functionality. Storage tanks enamelled to DIN 4753 are suitable for normal drinking water Insulation of the connections and the storage tank NOTE Insulate in accordance with applicable local standards and guidelines/directives. Check all hydraulic connections for leaks. Perform leak test Insulate all connections and pipes. NOTE The function of the pressure relief device must be checked at regular intervals. Draining The storage tank is drained via the drain valve (see page 18-19). Shut-off valves must remain closed during draining. The connection at the hot water outlet should be open to the atmosphere. 7

8 Technical Data WWS Manufacturer: ait-deutschland GmbH Tank name Type Domestic hot water tank ı Solar domestic hot water tank Hot water tank: Energy efficiency class according to ErP Standing loss according to ErP (at 65 C) W Tank volume according to ErP l Nominal capacity l Max. operating pressure (except SVGW) bar Test pressure bar Max. operating temperature C Corrosion protection according to Enamelled surface yes no Mg protective anode diameter x length mm x mm Heat exchanger heat pump: Exchanger area m² Pressure loss ı Flow bar ı l/h Exchanger capacity l Max. operating pressure bar Test pressure bar Max. operating temperature C Maximum heating output of the heat pump at heat source max.: kw Solar heat exchanger: Exchanger area m² Pressure loss ı Flow bar ı l/h Exchanger capacity l Max. operating pressure bar Test pressure bar Max. operating temperature C General unit data Dimensions: Diameter ı Height (see dimensioned drawing for rest) mm x mm Tilt dimension mm Domestic hot water connections Heating water connections Solar connections Net weight kg Cleaning flange Nominal size Recommended tightening torque for cleaning flange N.m Tests Heating element connections Heating element (optional) Maximum output of electric heating element kw Insulation: Rigid PU foam material yes no Insulation thickness mm as per DIN 4753 yes no Sheet metal jacket ı Foil jacket yes no 8

9 WWS 121 WWS 202 WWSB 202 WWS 303 WWS WWS 405 WWS 507 ı ı ı ı ı ı ı B B B C A C C DIN 4753 DIN 4753 DIN 4753 DIN 4753 DIN 4753 DIN 4753 DIN x x x x x x x ,45 2,28 2,15 3,50 3,50 5,00 7,00 0,017 ı 900 0,015 ı ,013 ı ,024 ı ,024 ı ,035 ı ,046 ı , I - - I - - I - - I - - I - - I - - I ı ı ı ı ı ı ı x G ¾" AG 2 x R 1" AG 2 x R 1" AG 2 x R 1¼" AG 2 x R 1¼" AG 2 x R 1¼" AG 2 x R 1¼" AG 2 x G 1" AG 2 x R 1" AG 2 x R 1" AG 2 x Rp 1¼" IG 2 x Rp 1¼" IG 2 x Rp 1¼" IG 2 x Rp 1¼" IG DN110 DN110 DN110 DN110 DN110 DN110 DN SVGW / SEV SVGW / SEV SVGW / SEV SVGW / SEV SVGW / SEV SVGW / SEV - Rp 1 ½" IG Rp 1 ½" IG Rp 1 ½" Rp 1 ½" Rp 1 ½" 2 x Rp 1 ½" - EHZI 45F EHZI 45F EHZI 45F EHZI 45F EHZI 45F EHZI 45F+EHZI45-1 x 4,5 1 x 4,5 1 x 4,5 1 x 4,5 1 x 4,5 2 x 4,5 + VIP ı ı ı ı ı ı ı 9

10 Technical Data WWS, SWWS Manufacturer: ait-deutschland GmbH Tank name Type Domestic hot water tank ı Solar domestic hot water tank Hot water tank: Energy efficiency class according to ErP Standing loss according to ErP (at 65 C) W Tank volume according to ErP l Nominal capacity l Max. operating pressure (except SVGW) bar Test pressure bar Max. operating temperature C Corrosion protection according to Enamelled surface yes no Mg protective anode diameter x length mm x mm Heat exchanger heat pump: Exchanger area m² Pressure loss ı Flow bar ı l/h Exchanger capacity l Max. operating pressure bar Test pressure bar Max. operating temperature C Maximum heating output of the heat pump at heat source max.: kw Solar heat exchanger: Exchanger area m² Pressure loss ı Flow bar ı l/h Exchanger capacity l Max. operating pressure bar Test pressure bar Max. operating temperature C General unit data Dimensions: Diameter ı Height (see dimensioned drawing for rest) mm x mm Tilt dimension mm Domestic hot water connections Heating water connections Solar connections Net weight kg Cleaning flange Nominal size Recommended tightening torque for cleaning flange N.m Tests Heating element connections Heating element (optional) Maximum output of electric heating element kw Insulation: Rigid PU foam material yes no Insulation thickness mm as per DIN 4753 yes no Sheet metal jacket ı Foil jacket yes no 10

11 WWS 806 WWS 1006 SWWS 404 SWWS 506 SWWS 806 SWWS 1008 ı ı ı ı ı ı C C DIN 4753 DIN 4753 DIN 4753 DIN 4753 DIN 4753 DIN x x520 33x x x x x x520 33x x520 5,60 5,60 3,50 4,30 4,60 5,60 0,085 ı ,085 ı ,024 ı ,025 ı ,073 ı ,086 ı , ,62 1,85 1,80 3,00 - I - - I - 0,011 ı ,013 ı ,033 ı ,051 ı , ı ı ı ı ı ı x Rp 2" IG 2 x Rp 2" IG 2 x R 1¼" AG 2 x R 1¼" AG 2 x Rp 2" IG 2 x Rp 2" IG 2 x Rp 1¼" IG 2 x Rp 1¼" IG 2 x Rp 1¼" IG 2 x Rp 1¼" IG 2 x Rp 1¼" IG 2 x Rp 1¼" IG x Rp 1¼" IG 2 x Rp 1¼" IG 2 x Rp 1¼" IG 2 x Rp 1¼" IG DN110 + DN 200 DN110 + DN 200 DN110 DN110 DN110 + DN 200 DN110 + DN SVGW / SEV SVGW / SEV SVGW / SEV SVGW / SEV SVGW / SEV SVGW / SEV Rp 1 ½" Rp 1 ½" 2 x Rp 1 ½" 2 x Rp 1 ½" Rp 1 ½" Rp 1 ½" EHZI 45 EHZI 45 EHZI 45F+EHZI45 EHZI 45F+EHZI45 EHZI 45 EHZI 45 1 x 4,5 1 x 4,5 2 x 4,5 2 x 4,5 1 x 4,5 1 x 4, ı ı ı ı ı ı 11

12 Installation plan WWS 121 > 740 > 200 > 150 FS > 1560 > 500 FS > 500 > 1170 OKF Legende: DE All dimensions in mm. We reserve the right to modify technical specifications without prior notice > 20 OKF FS Finished floor level Free space for service purposes C 1 MF >800 Legend: DE All dimensions in mm. We reserve the right to modify technical specifications without prior notice. C Top view MF Minimum area to ensure ability to operate and service 1 Storage tank >

13 Dimensioned drawings WWS 121 B A E C Legende: DE819422b A B C E Front view Side view from right Plan view Rear view Item Name Dim. Nominal volume Net weight 1 Hot water G3/4" AG 115 Liter 69 kg 2 Cold water G3/4" AG 3 Service area with protective anode (galvanic anode), cleaning flange, thermowell with sensor 4 Heating water inlet G1" AG 5 Circulation Rp3/4" IG 6 Heating water outlet G1" AG 7 Draining Rp1/2" IG 13

14 Dimensioned drawings WWS 202 / WWSB Legend: EN Dimensions in mm Item Designation Dim. 1 Cold water / draining R 1" AG 2 Heating water, return R 1" AG 3 Circulation R 3/4" AG 4 Heating water, flow R 1" AG 5 Hot water R 1" AG 6 Cleaning flange DN Sensor pocket with sensor Øi 7 8 Protective anode Ø26 Nominal volume Smooth tube heat exchanger Net weight Tilted height WWS Liter 2,28 m² 80 kg 1380 WWSB Liter 2,15 m² 80 kg

15 Dimensioned drawings WWS 303, WWS 303.1, WWS 507 Legend: All dimensions in mm. EN819291c Item Designation Dim. 1 Cold water / draining R 1 1/4" AG 2 Heating water, return R 1 1/4" IG 3 Circulation R 3/4" IG 4 Heating water, flow R 1 1/4" IG 5 Hot water R 1 1/4" AG 6 Sensor pocket with sensor Øi 7 7 Socket for electric heating element (in WWS 507 only) R 1 1/2" IG 8 Protective anode Ø33 9 Cleaning flange DN 110 H1 H2 H3 H4 H5 WWS WWS WWS Nominal volume Net weight Tilted height Smooth tube heat exchanger WWS litre 135 kg m² WWS litre 170 kg m² WWS litre 218 kg m² 15

16 WWS 806 WWS 1006 Dimensioned drawings 1 6 H6 H5 H4 H3 H H7 H8 H13 H9 H10 H11 H12 H c Item Name Dim. 1 Domestic hot water R 2" IG 2 Circulation R 1" IG 3 Heating water inlet R 1 1/4" IG 12 Ø Heating water outlet R 1 1/4" IG WWS 806 WWS Cold water c R 2" IG H Thermometer Technische Änderungen R 1/2" vorbehalten IG 7 Anode Alle Ø32x700 Maße in mm H R 1 1/4" IG Pos. Bezeichnung Dim. WWS 806 H3 WWS Anode Ø32x520 R 1 1/4" IG 1 Brauchwarmwasser R 2" IG H1 175 H Cleaning 2 flangezirkulation DN 200 R 1" IG H H Sensor, depth 3 max. Heizwasser Eintritt R 1/2" IG R 1 1/4" IG H Heizwasser Austritt R 1 1/4" IG H H Kaltwasser R 2" IG H Venting R 1 1/4 IG H Thermometer R 1/2" IG H Sensor sleeve, 7 Anode length Ø32x700 R 1/2" IG R 1 1/4" IG H7 350 H Anode Ø32x520 R 1 1/4" IG H8 690 H Reinigungsflansch DN 200 H Cleaning flange DN Fühler, Tiefe max. 200 R 1/2" IG H H Electric heating 11 Entlüftung R 1 1/2 IG R 1 1/4 IG H H element 12 Fühlerhülse, Länge 1000 R 1/2" IG H H Reinigungsflansch DN 110 H Elektroheizstab R 1 1/2 IG H Kippmaß Nominal Bare tube heat Net weight Glattrohr- ohne Tilt dimension without Nenninhalt Wärmetauscher Nettogewicht Isolierung capacity exchanger insulation WWS Liter 5,6 m² 290 kg 2020 WWS Liter 5,6 m² 290 kg WWS Liter 5,6 m² 340 kg 2220 WWS Liter 5,6 m² 340 kg 2220 Datum: Name: Maßbild Zeichnungs-N Gezeichnet: Markieton WWS 806, WWS 1006 Geprüft: Stenglein Seite: 1/1 Zust. Änderungen: Datum: Name: "-" ÄM 040/ Markieton Ø

17 SWWS 404 Dimensioned drawings Legend: All dimensions in mm. EN819305b Item Designation Dim. 1 Cold water / draining R 1 1/4" AG 2 Solar, return R 1 1/4" IG 3 Sensor pocket for solar sensor Ø i 14 4 Solar, flow R 1 1/4" IG 5 Heating water, return R 1 1/4" IG 6 Circulation R 3/4" IG 7 Heating water, flow R 1 1/4" IG 8 Hot water R 1 1/4" AG 9 Sensor pocket with sensor Øi 7 10 Protective anode Ø Socket for electric heating element R 1 1/2" IG 12 Cleaning flange DN 110 Nominal volume Net weight Tilted height 345 litre 185 kg 1720 Smooth tube heat exchanger Hot water circuit 3.50 m² Solar circuit 1.62 m² 17

18 Dimensioned drawings SWWS 506 Legend: All dimensions in mm. EN819065d Item Designation Dim. 1 Cold water / draining R 1 1/4" AG 2 Solar, return R 1 1/4" IG 3 Sensor pocket for solar sensor Ø i 14 4 Solar, flow R 1 1/4" IG 5 Heating water, return R 1 1/4" IG 6 Circulation R 3/4" IG 7 Heating water, flow R 1 1/4" IG 8 Hot water R 1 1/4" AG 9 Sensor pocket with sensor Øi 7 10 Protective anode Ø33 11 Socket for electric heating element R 1 1/2" IG 12 Cleaning flange DN 110 Nominal volume Net weight Tilted height 445 litre 210 kg 2100 Smooth tube heat exchanger Hot water circuit 4.30 m² Solar circuit 1.85 m² 18

19 SWWS 806 SWWS 1008 Dimensioned drawings Legend: EN819339b All dimensions in mm. Item Designation 1 Domestic hot water Dim. R 2" IG H1 SWWS SWWS Heating water inlet R 1 1/4" IG H Circulation R 1" IG H Solar inlet R 1 1/4" IG H Sensor, maximum depth 200 R 1/2" IG H Solar outlet R 1 1/4" IG H Cold water R 2" IG H Thermometer R 1/2" IG H Anode Ø32x700 R 1 1/4" IG H Cleaning flange DN 220 H Anode Ø32x520 R 1 1/4" IG H Ventilation R 1 1/4" IG H Sensor pocket, length 1000 R 1/2" IG H Heating water outlet R 1 1/4" IG H Weight SWWS kg 2000 SWWS kg 2160 Tilted height Reducing flange DN 220 to DN 120 enclosed in extra box 19

20 Domestic hot water tank Connection instructions Legend: Designation 1 Shut-off valve EN830032b 2 Pressure reducing valve 3 Test valve 4 Backflow preventer 5 Pressure gauge connection socket 6 Drain valve 7 Safety valve 8 Ventilation 9 Shut-off valve with draining 10 Check valve 11 Storage tank charge pump 12 Solar charge pump 13 Circulation pump 14 Cold water connection (to DIN 1985) WW KW Z HV HR SV SF SR AZ Hot water Cold water Circulation Heating, flow Heating, return Flow, brine circuit Solar sensor Return, brine circuit Circulation connection (only if absolutely necessary) 14 AZ NOTE. The positions of the individual connections illustrated here may differ from the positions of the connections on your tank. Therefore, for the actual positions of the connections, please refer to the dimensioned diagram for the respective tank type or always note and follow the allocation of the connections indicated by the stickers on the tank. 20

21 Connection instructions Solar domestic hot water tank Legend: Designation 1 Shut-off valve EN830032b 2 Pressure reducing valve 3 Test valve 4 Backflow preventer 5 Pressure gauge connection socket 6 Drain valve 7 Safety valve 8 Ventilation 9 Shut-off valve with draining 10 Check valve 11 Storage tank charge pump 12 Solar charge pump 13 Circulation pump 14 Cold water connection (to DIN 1985) WW KW Z HV HR SV SF SR AZ Hot water Cold water Circulation Heating, flow Heating, return Flow, brine circuit Solar sensor Return, brine circuit Circulation connection (only if absolutely necessary) 14 AZ NOTE. The positions of the individual connections illustrated here may differ from the positions of the connections on your tank. Therefore, for the actual positions of the connections, please refer to the dimensioned diagram for the respective tank type or rather always note and follow the allocation of the connections indicated by the stickers on the tank. 21

22 22

23 EC Declaration of Conformity The undersigned confirms that the following designated device(s) as designed and marketed by us fulfill the standardized EC directives, the EC safety standards and the product-specific EC standards. In the event of modification of the device(s) without our approval, this declaration shall become invalid. Designation of the device(s) Unit model WWS 121 WWS 202 WWSB 202 WWS 303 WWS WWS 405 WWS 507 WWS 806 WWS 1006 SWWS 404 SWWS 506 SWWS 806 SWWS 1008 Number Unit model SBWS SBWS SBWS WPS WTPSK UPS TPS TPSK TPSK TPS TPS TPS MFS600S MFS 830S MFS 1000S Number EC Directives Standardized EN 2009/125/EG EN 12897: /30/EU Company: ait-deutschland GmbH Industrie Str Kasendorf Germany Place, date: Signature: Kasendorf, UK Jesper Stannow Head of Heating Development 23

24 Made by ait-deutschland GmbH

3-way switching valve

3-way switching valve Operating Manual UK 3-way switching valve for domestic hot water charging USV 1" AG USV 5/4" AG USV 6/4" IG UK805189 / 201109 Translation of the original instruction manual Please read first This operating

More information

Installation manual Operating instructions

Installation manual Operating instructions WIKORA GmbH Friedrichstr. 9 89568 Hermaringen Phone: (07322) 9605-0 Fax: (07322) 9605-30 email: contact@wikora.de Installation manual Operating instructions DHW storage tank UNO/DUO/H/WPSOL Installation

More information

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A Installation instructions for contractors VIESMNN Vitocell 300-V/W Type EVI- DHW cylinder with internal indirect coil 160 to 500 l VITOCELL 300-V/W 3/2017 Dispose after installation. Safety instructions

More information

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l Installation instructions for contractors VIESMANN Vitocell 300-B Type EVBA-A Dual mode DHW cylinder, 300 and 500 l VITOCELL 300-B 1/2017 Dispose after installation. Safety instructions Please follow these

More information

WZS 82(H)(K)3M 20 I B0W I I I (263) (288) 7.0

WZS 82(H)(K)3M 20 I B0W I I I (263) (288) 7.0 WZS 4(H)(K)M WZS 6(H)(K)M WZS 8(H)(K)M WZS (H)(K)M WZS 1(H)(K)M 0 I 60-5 5 B0W65 1 4 I I I -1 50 (58) 178 58 65 50 60 0 I 60-5 5 B0W65 1 4 I I I -1 55 (6) 178 58 65 50 60 0 I 60-5 5 B0W65 1 4 I I I -1

More information

Installation and operating instructions. DK energy storage and DK energy buffer

Installation and operating instructions. DK energy storage and DK energy buffer Installation and operating instructions DK energy storage and DK energy buffer Edition: 08-2015 1 Preliminary note With this DK energy storage / DK energy buffer you purchased a DK quality product. The

More information

Heat Pumps. Compact. Device Information. Operating manual supplement. LWC Series

Heat Pumps. Compact. Device Information. Operating manual supplement. LWC Series Device Information UK Air/Water Operating manual supplement Compact Heat Pumps LWC Series Please read first The Special Version Device Information is a component of the product. It complements the operating

More information

Technical information Installation instructions. Modul-plus (F21-52) High performance calorifiers

Technical information Installation instructions. Modul-plus (F21-52) High performance calorifiers Technical information Installation instructions Modul-plus (F21-52) High performance calorifiers These instructions apply to the following types: 5/6-Modul-plus F (21) 5/6-Modul-plus F (31) 5/6-Modul-plus

More information

PRODUCT INFORMATION. Solar DHW storage tank SKL. Technical description. High performance solar tank, bivalent

PRODUCT INFORMATION. Solar DHW storage tank SKL. Technical description. High performance solar tank, bivalent We develop for your future PRODUCT INFORMATION High performance solar tank, bivalent Technical description Solarbayer GmbH (50.14) Solarbayer GmbH 1 Content Safety regulations...........................................................................

More information

Installation instructions

Installation instructions 2Power storage tank Installation instructions This installation construction contains important advice for handling, installing and starting up a 2Power solar plant. Read these advice carefully before

More information

WH-TD20B3E5 WH-TD30B3E5

WH-TD20B3E5 WH-TD30B3E5 Order No: PHAAM1004143C2 WH-TD20B3E5 WH-TD30B3E5 WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain

More information

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-08 Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose...

More information

INDIRECT WATER HEATERS

INDIRECT WATER HEATERS INSTRUCTIONS INDIRECT WATER HEATERS ST-300D, ST-200D HEAT PUMPS STAINLESS STEEL INDIRECT FIRED WATER HEATERS ST-200D, ST-300D 1. Product Description Indirect fired water heaters ST-200D and ST-300D are

More information

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual Installation and Operation Manual IDRA PLUS DS Solar Solar storage cylinder EN Installation and Operation Manual GENERAL INFORMATION This - comprises pages. Rev. manual, Code ENGLISH General information

More information

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler Installation instructions for contractors VIESMANN Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler VITORONDENS 200-T 5/2013 Dispose after installation. Safety instructions Please

More information

Domestic Hot Water Tank

Domestic Hot Water Tank Installation and Operating Manual Domestic Hot Water Tank WWKS 300 WWKS 500 EN For the professionals Read carefully before installation Table of Contents 1 Use............................. 3 2 Safety Instructions

More information

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use! Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 74363 Güglingen Telefon +49 7135-102-0 Service +49 7135-102-211 Telefax +49 7135-102-147 info@afriso.de

More information

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors Service instructions for contractors VIESMANN Vitocell 300-B Type EVB DHW cylinder, 300 and 500 l Vitocell 300-V Type EVI DHW cylinder, 200 to 500 l For applicability, see the last page VITOCELL 300-B

More information

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC 2CKA001473B9007 19.05.2017 System Manual Busch-Infoline Handicapped toilet signal set 1510 UC-... -101 Table of contents Table of contents 1 Notes on the instruction manual... 3 2 Safety... 4 2.1 Information

More information

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions Operating Instructions Accessory Units Melitta Cafina XT Series Melitta Professional Coffee Solutions Contents General... 4. Manufacturer information... 4.2 About these instructions... 4.3 Explanation

More information

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50 -30 Installer manual Air/air heat pump -40/50 IHB GB 1516-1 331554 Table of Contents 1 Important information 2 5 Installation 7 Safety information 2 Model combinations 7 Read before starting the installation

More information

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15 INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15 01 CONTENTS Special information 2 General information 3 Safety 5 Appliance description, cleaning, care & maintenance 7 Appliance

More information

Read these instructions before using and keep them available at all times!

Read these instructions before using and keep them available at all times! A120407 V4/0713 GB/UK ENGLISH Translation of the original instruction manual Read these instructions before using and keep them available at all times! 1. General information... 16 1.1 Information about

More information

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3 INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHWE50AV EKHWET50AV EKHWE00AV EKHWE00AV EKHWE00AZ EKHWE00AZ 4 5 6 7 x x x 4x x x x EKHWE50~00 EKHWET50 50 50 0 0 00 50 700

More information

Installation manual plugs and connectors QUICK-CONNECT (63 A)

Installation manual plugs and connectors QUICK-CONNECT (63 A) EN Installation manual plugs and connectors QUICK-CONNECT (63 A) 60003217 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal

More information

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA Installation and service instructions for contractors VIESMANN Vitocell 340-M/360-M Type SVKA Type SVSA Combi cylinder 750 and 950 litre capacity VITOCELL 340-M/360-M 4/2009 Please keep safe. Safety instructions

More information

HPWH 300 HPWH 300HE. Installation and Operating Instructions. Hot Water Heat Pump for Outdoor Installation. English FD 9501

HPWH 300 HPWH 300HE. Installation and Operating Instructions. Hot Water Heat Pump for Outdoor Installation. English FD 9501 HPWH 300 HPWH 300HE Installation and Operating Instructions Hot Water Heat Pump for Outdoor Installation FD 9501 Table of contents 1 Please read immediately... EN-2 1.1 Important notes... EN-2 1.2 Intended

More information

80-140 80-180 95-260 70-360 65-400 65-500 Installation User and Service Manual TM your installer TM Warning Read this manual carefully before first using the water heater. Failure to read this manual and

More information

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler Installation instructions for contractors VIESMANN Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler VITORONDENS 200-T 6/2011 Dispose after installation. Safety instructions Please

More information

Accessory for heat pumps. Operating Manual. Wall-mounted controller bUK Translation of the operating manual

Accessory for heat pumps. Operating Manual. Wall-mounted controller bUK Translation of the operating manual Accessory for heat pumps Operating Manual Wall-mounted controller UK 83058800bUK Translation of the operating manual Table of Contents About this operating manual...3 Validity...3 Reference documents...3

More information

ECOplus Solar Cylinder

ECOplus Solar Cylinder TECHNICAL INFORMATION ECOplus Solar Cylinder Minimized Heat Loss due to convection brakes in the pipe connections, the new close-fitting, 00-mm thick PU soft foam jacket insulation, 0-mm thick and close

More information

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 0 l capacity Datasheet Part no. and prices: see pricelist VITOCELL 300-V Type EVA and EVI Vertical DHW cylinder made from stainless steel 5/2012 Product

More information

Operating Instructions!

Operating Instructions! Operating Instructions! 3 4 Oscillation MO 16.2 / MO 40 Example 3 4 MO 16.2 The unit has to be strictly used according to the instruction manual. Keep the unit away from children and from persons not instructed

More information

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A) EN Installation manual surface mounting plugs and socket outlets, panel 60003214 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3

More information

Pump assembly Instruction manual

Pump assembly Instruction manual Instruction manual EN Version 2.0 /Release 06/2012 Table of content 1 Key background information...3 1.1 Limitation of liability...3 1.2 Responsibilities of the operator...3 1.3 Documentation...3 1.3.1

More information

BK 45 BK 45-U BK 45-LT BK 46

BK 45 BK 45-U BK 45-LT BK 46 Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-07 Contents Preface...3 Availability...3 Text layout...3 Safety...3 Usage for the intended purpose...3 Basic safety notes...4

More information

Translation of the assembly instructions with operating instructions and technical appendix

Translation of the assembly instructions with operating instructions and technical appendix BA Ex-SBU Switch box type SBU-x(1,2,3)x Translation of the assembly instructions with operating instructions and technical appendix In accordance with EU ATEX Directive 2014/32/EU In accordance with EU

More information

PRODUCT INFORMATION. Technical description. Hygienic stratification storage tank HSK ÖKO Universal heat center for legionella safe preparation of DHW

PRODUCT INFORMATION. Technical description. Hygienic stratification storage tank HSK ÖKO Universal heat center for legionella safe preparation of DHW We develop for your future! PRODUCT INFORMATION Hygienic stratification storage tank Universal heat center for legionella safe preparation of DHW Technical description Solarbayer GmbH (18.12) Solarbayer

More information

235L G. Original-Gebrauchsanleitung V1/1115

235L G. Original-Gebrauchsanleitung V1/1115 235L 700335G Original-Gebrauchsanleitung V1/1115 GB/UK ENGLISH Table of contents 1.Safety... 20 1.1 Safety instructions... 20 1.2 Key to symbols... 23 1.3 Proper use... 24 2. General information... 25

More information

aurostor Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VIH S GB...

aurostor Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VIH S GB... Installation and maintenance instructions For the competent person Installation and maintenance instructions aurostor VIH S GB.../3 GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-4859

More information

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm Safety instructions The washing machine is heavy - take care when lifting. Caution: frozen hoses may rip/burst. Do not install the washing machine in areas exposed to frost or outdoors. The washing machine

More information

ENAMELED INDIRECT WATER HEATERS

ENAMELED INDIRECT WATER HEATERS INSTRUCTIONS ENAMELED INDIRECT WATER HEATERS ST-300DE HEAT PUMPS Please read this manual carefully before installing the heater! Dear Customer, Sinclair Corporationt Ltd. thanks you for your decision

More information

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................

More information

HKF 8180 Operating instructions

HKF 8180 Operating instructions Operating instructions EN Version 1.0en /Edition 05/2013 Contents 1 Important basic information... 3 1.1 Limitation of liability... 3 1.2 Operator's responsibilities... 3 1.3 Documentation... 3 1.3.1 Content

More information

CIRCO 6 Solar Circulation Unit

CIRCO 6 Solar Circulation Unit TECHNICAL INFORMATION / INSTALLATION INSTRUCTIONS CIRCO Solar Circulation Unit CIRCO Solar Circulation Unit in combination with the intelligent SUNGO controllers, it is the safe and reliable heart of a

More information

Stainless steel quality Heating coil at bottom of tank Flattened heating coil (WT) Unique Anti-Legio design Tank operating pressure max.

Stainless steel quality Heating coil at bottom of tank Flattened heating coil (WT) Unique Anti-Legio design Tank operating pressure max. www.ecotherm.com Stainless steel quality Heating coil at bottom of tank Flattened heating coil (WT) Unique Anti-Legio design Tank operating pressure max. 10 bar TYPE ESWH-...-2 TYPE ESWH-...-1 Stainless

More information

80-140 80-180 95-260 70-360 65-400 Installation User and Service Manual TM your installer TM Warning Read this manual carefully before first using the water heater. Failure to read this manual and to follow

More information

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN BN30 EN OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN table of contents Notes regarding the operating manual... 1 Safety... 2 Information about the device... 2 Technical data... 3 Transport

More information

WXHAP Washington Street Melrose, MA Phone Toll Free Visit us at

WXHAP Washington Street Melrose, MA Phone Toll Free Visit us at WXHAP 200 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com WXHAP 200 Operating Instructions LT LV EE SL SK HU PL CZ TR GR FI DK

More information

Brine/water heat pumps. Operating Manual SWC V H hUK Translation into English of the original German operating manual

Brine/water heat pumps. Operating Manual SWC V H hUK Translation into English of the original German operating manual Brine/water heat pumps Operating Manual SWC V H1 UK 83057100hUK Translation into English of the original German operating manual Contents 1 About this operating manual...3 1.1 Validity...3 1.2 Reference

More information

Installation, operating and servicing instructions

Installation, operating and servicing instructions English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes

More information

Technical information for installation and operation

Technical information for installation and operation Technical information for installation and operation PR 24002.65 12-04-2016 Subject to technical modifications LogoFresh 100 & 120 fresh water station Electronically controlled GB Meibes System-Technik

More information

STORAGE WATER HEATERS

STORAGE WATER HEATERS Owners Manual STORAG WATR HATRS RBC 200, RBC 300, RBC 400, RBC 500, RBC 500HP, RBC 750, RBC 1000, RBC 1000HP, RBC 1500, RBC 2000, RBC 3000 N v. 1.4 CONTNTS 1 Description... 3 1.1 Models... 3 1.2 Tank protection...

More information

Moisture inside the drum is due to final testing.

Moisture inside the drum is due to final testing. Safety instructions Scope of delivery depending on model Moisture inside the drum is due to final testing. Removing the transport braces Water connection depending on model The washing machine is heavy

More information

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................

More information

Operating Instructions UniTech Perfect

Operating Instructions UniTech Perfect Operating Instructions UniTech Perfect Technische Daten Rated Voltage Power Consumption Max. flow rate Max. head height Cable Protection Dimensions Weight Perfect 5000 49W 5100 l/h 1,85m Perfect 7000 78W

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS 2587967 EN 1610 READ AND SAVE THESE INSTRUCTIONS This manual must be read in conjunction with Nortec ME Control installation manual and operation manual! ADDENDUM MANUAL Adiabatic air humidification/air

More information

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE INSTRUCTION MANUAL INSTALLATION AND SERVICING AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE About this manual These installation and maintenance instructions contain important information

More information

CALORIFIERS (Energy Storage Tanks) for domestic, commercial and industrial applications.

CALORIFIERS (Energy Storage Tanks) for domestic, commercial and industrial applications. CALORIFIERS (Energy Storage Tanks) Complete Favorite high choice efficient for system fresh domestic solutions hot water. for domestic, commercial and industrial applications. Calorifiers Energy storage

More information

Instructions For Use ENG. LED Magnifier Lamp

Instructions For Use ENG. LED Magnifier Lamp Instructions For Use ENG OPTICA 488 LED Magnifier Lamp ENG Table of Contents 1. For your safety...3 1.1 Designated use...3 1.2 Safety instructions...3 1.3 Warning levels...4 2. Mounting...4 2.1 Mounting

More information

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17 VIESMANN VITOCELL 300-V Vertical DHW cylinder 130to500litrecapacity Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 17 VITOCELL 300-V Type EVA and EVI Vertical DHW cylinder

More information

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

INSTALLATION, COMMISSIONING AND OPERATING MANUAL INSTALLATION, COMMISSIONING AND OPERATING MANUAL 1 YTBV-D-CE42_0109 CONTENT Available models and capacities Supplier information Warranty Safety Emergency stops/ shutdowns About this manual Models Physical

More information

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting EN Installation manual extra-low-voltage socket outlets for panel- and 60003221 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal

More information

Mounting and operating instructions KEMPER KTS temperature-controlled 3-directional reversing valve Figure DN 32 DN 80

Mounting and operating instructions KEMPER KTS temperature-controlled 3-directional reversing valve Figure DN 32 DN 80 Mounting and operating instructions KEMPER KTS temperature-controlled 3-directional reversing valve Figure 955 01 DN 32 DN 80 Figure 1: DN 32 - DN 50 Figure 2: DN 65 - DN 80 Table of Contents 1 General

More information

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHTS00A EKHTS60A EKHTSP00AA EKHTSP60AA 6 7 x x x x x x x 0 mm 0 D B >0 C >0 0 >0 A >600 H 0 Ø60 0 0 77 8 6 7 778 6 0 6 6 00

More information

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40 1 Safety instructions Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically

More information

VENTOWER. Operating Manual UK

VENTOWER. Operating Manual UK Operating Manual UK VENTOWER 800600cUK Translation of the original instruction manual ait-deutschland GmbH Please read first This operating manual provides important information on the handling of the

More information

Water heater type SGW(S) Vulcan

Water heater type SGW(S) Vulcan Cat. No./ Serial No.... QC Date of manufacture... Installation and Operating Manual / Warranty Card Water heater type SGW(S) Vulcan Capacity: 100 l 120 l 140 l 200 l Protection: Magnesium anode Titanium

More information

Professional. Operating Instructions UK. Brine/Water. Heat pumps NIBE TM AP-BW30

Professional. Operating Instructions UK. Brine/Water. Heat pumps NIBE TM AP-BW30 Operating Instructions UK Brine/Water Professional Heat pumps NIBE TM AP-BW30 We reserve the right to make technical changes. 83050906bUK Translation of the operating manual Please read first These operating

More information

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan Installation plan Washing machine PW 6055 AV/LP PW 6065 AV/LP To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation

More information

TERMO Combi Cylinder TECHNICAL INFORMATION

TERMO Combi Cylinder TECHNICAL INFORMATION TECHNICAL INFORMATION TERMO Combi Cylinder Tank-In-Tank System using solar energy for hot water and heating support. For integration into the heating circuit as return flow booster or hydraulic compensator.

More information

Instruction Manual. Automatic fuel oil de-aerator SMART-FLO 3/K B100 COMPATIBLE

Instruction Manual. Automatic fuel oil de-aerator SMART-FLO 3/K B100 COMPATIBLE Sid Harvey s 605 Locust Street Garden City, NY 11530 Instruction Manual Automatic fuel oil de-aerator SMART-FLO 3/K Read manual before use! Observe all safety information! Keep manual for future use! 05.2015

More information

Air/Water Heat Pumps Indoor Installation. Operating Manual. VenTower dUK Translation into English of the original German operating manual

Air/Water Heat Pumps Indoor Installation. Operating Manual. VenTower dUK Translation into English of the original German operating manual Air/Water Heat Pumps Indoor Installation Operating Manual VenTower UK 800600dUK Translation into English of the original German operating manual Please read first This operating manual provides important

More information

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................

More information

AUTOMATIC VACUUM UNIT

AUTOMATIC VACUUM UNIT USER MANUAL (REV. D) AUTOMATIC VACUUM UNIT Part No. / Art. Nr. / Réf.: 29726, 29736 1 1.INTRODUCTION A SAFETY REGULATIONS manual is delivered with this manual. MEANING OF THE PICTOGRAMS USED IN THIS MANUAL

More information

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use. Operating manual Temperature probe GTL 369 GTL 369M GTL 389 GTL 389M Please keep the manual for future use. L02.0.3X.6C-01 GREISINGER electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS 17 West Street West Hatfield, MA 01088 Phone: (413) 247-3380 * (800) 582-8423 Fax: (413) 247-3369 E-mail: info@stiebel-eltron-usa.com SB 150, SB 200 Glass Lined Indirectly Fired Water Heaters With Single

More information

Installation and instruction manual SOLAR STATION

Installation and instruction manual SOLAR STATION INSTALLATION AND INSTRUCTION MANUAL SOLAR STATION Installation and instruction manual SOLAR STATION SST 25-1E / SST25-2E EN April 2015 1 Table of contents Usage 3 Warranty 3 Safety instructions and symbol

More information

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45 GESTRA Steam Systems DK 45 EN English Installation Instructions 818676-00 Steam Trap DK 45 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED

More information

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. INSTALLATION, OPERATION & SERVICE MANUAL FOR COOLER TYPES OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. 1. Introduction This manual is a guide for the installation, maintenance

More information

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage Model: 1090 1 Safety instructions Float-Controlled Condensate Trap, PN 16 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination

More information

AE PV Heating Element. Screwing in Heating Unit. Installation Manual. Version 01.6

AE PV Heating Element. Screwing in Heating Unit. Installation Manual. Version 01.6 AE PV Heating Element Screwing in Heating Unit Installation Manual Version 01.6 Title Type of Documentation Purpose of the Documentation Publisher Legal Reservation Copyrights AE PV Heating Element Warm

More information

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier OM001 Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier These operating and maintenance instructions are for standard semi-storage calorifiers (vessels fitted with

More information

USER INSTRUCTIONS GRINDING MACHINES MOD.135SH MOD.145SH MOD.155 S. Subfloor Treatment. Janser GmbH Machines & Tools Work Clothing

USER INSTRUCTIONS GRINDING MACHINES MOD.135SH MOD.145SH MOD.155 S. Subfloor Treatment. Janser GmbH Machines & Tools Work Clothing Subfloor Treatment GRINDING MACHINES USER INSTRUCTIONS MOD.135SH 112 455 000-230 Volt 112 455 600-120 Volt MOD.145SH 112 560 000-230 Volt 112 560 600-120 Volt MOD.155 S 112 750 000-230 Volt 112 750 600-120

More information

FSW300 Series Flow Switch

FSW300 Series Flow Switch . FSW300 Series Flow Switch - 2 - Series FSW300 Series FSW300 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Intended use... 5 1.1.1 Reed contact - Switching of

More information

SECTION DOMESTIC WATER HEATERS

SECTION DOMESTIC WATER HEATERS SECTION 223500 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

INSTALLATION INSTRUCTIONS USER GUIDE

INSTALLATION INSTRUCTIONS USER GUIDE INSTALLATION INSTRUCTIONS USER GUIDE Standard Rangehood HF60LX4 and HF60LW4 model NZ AU CONTENTS Safety and warnings 3 Installation instructions 5 Operating instructions 13 Cleaning and maintenance 14

More information

General safety precautions English

General safety precautions English English 1 1 1.1 About the documentation The original documentation is written in English. All other languages are translations. The precautions described in this document cover very important topics, follow

More information

Model: 1100 Float-Controlled Condensate Trap, PN 25

Model: 1100 Float-Controlled Condensate Trap, PN 25 1 Safety instructions Model: 1100 Float-Controlled Condensate Trap, PN 25 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination

More information

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN TTK 75 ECO EN OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN Table of contents Notes regarding the operating manual... 01 Information about the device... 02 Safety... 04 Transport...05 Start-up...05

More information

Friwa Compact. Operating instructions EN

Friwa Compact. Operating instructions EN Operating instructions EN Version 1.1 / Edition 09/2013 Contents 1 Key background information... 3 1.1 Limitation of liability... 3 1.2 Responsibilities of the operator... 3 1.3 Documentation... 3 1.3.1

More information

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

User Manual GV25 GV35 GV702. Company information:   Original instructions GV12066 (1) User Manual Original instructions GV25 GV35 GV702 Company information: www.vipercleaning.eu info-eu@vipercleaning.com GV12066 (1) 2012-04-10 USER MANUAL ENGLISH TABLE OF CONTENTS Introduction... 4 Manual

More information

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan Installation plan Washing machine PW 5064 MOPSTAR 60 To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation and commissioning

More information

Installation and Operating Instructions. Hot water heat pump

Installation and Operating Instructions. Hot water heat pump Item no.: XXXXXX-20/10/2004 Installation and Operating Instructions Hot water heat pump HP 180 (I S WPS 180) HP 300 (I S WPS 300) HP 300 W (I S WPS W 300) HP 300 WW (I S WPS WW 300) Information Brandmarket

More information

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb. Edition 06.14 GB Operating and installation instructions Lago FB digital remote control Translation from the German 2014 Elster GmbH Safety Please read and keep in a safe place Please read through these

More information

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from

More information

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100 1 Safety instructions Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead

More information

Flamco. Water heaters, storage tanks and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS WATER HEATERS, STORAGE TANKS

Flamco. Water heaters, storage tanks and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS WATER HEATERS, STORAGE TANKS WATER HEATERS, STORAGE TANKS 6 Flamco and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS 2007 edition / UK Flamco glass lined water heaters for potable and heating installations Flamco

More information

Reflex Longtherm. Soldered plate-type heat exchanger. Operating instructions

Reflex Longtherm. Soldered plate-type heat exchanger. Operating instructions Reflex Longtherm Soldered plate-type heat exchanger 09-2016 EN Operating instructions English Refle x Longth erm Contents 09-2016 Contents 1 Safety... 3 1.1 Personnel requirements... 3 1.2 Instructions

More information

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER GREENGLO MAINS PRESSURE INTEGRATED WATER HEATER SINGLE COIL SERIES & DOUBLE COIL SERIES GREENGLO SAVER Customer Congratulations for choosing a GreenGlo

More information