SOUTHERN PRIDE VSP HOOD
|
|
- Mavis Simpson
- 6 years ago
- Views:
Transcription
1 OPERATOR MANUAL IMPORTANT INFORMATION, KEEP FOR OPERATOR This manual provides information for: SOUTHERN PRIDE VSP FOR A SOUTHERN PRIDE BBQ OVEN UL file # for Southern Pride oven MH943 UL file # for Avtec VSP Hood MH2966 THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL. NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage, including concealed damage. Unified Brands suggests that if you are suspicious of damage to make a notation on the delivery receipt. It will be the responsibility of the consignee to file a claim with the carrier. We recommend that you do so at once. Manufacture Service/Questions, call Southern Pride at Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recommends referencing our product line websites, unifiedbrands.net, for the most updated product information and specifications. PART NUMBER SP-/06, REV. A (07/) Southern Pride Distributing 472 South Mill St Alamo, TN fax
2 Table of Contents Safety Procedures...page 2 Important Product Information... page 3 Regulatory Information... page 4 Option : Door Installation... page 5 Option 2: Through the Wall Installation... page 6 Option 3: Through the Wall Installation with Curb Assembly... page 7 Installation Instructions: Standard VSP Top Collar... page 8 Installation Instructions: Rear Collar VSP... page 9 Installation Instructions: Exhaust Fan & Duct for Option 3... page 0 Electrical Connection... page Warranty... page 2-4 Ventilation Maintenance Guide... page 5 Diagrams... page -28 Safety Procedures Do not attempt to service this unit yourself as removing covers may cause unnecessary exposure to dangerous voltage. Never connect the unit to a power source while standing in water. Wet hands and wet floors should be avoided when connecting any electrical appliance to a power outlet. Fans may have multiple power connections. Make sure all fans are isolated from power prior to performing maintenance. 2 OM-SP VSP
3 Important Product Information Warranty AVTEC INDUSTRIES INC. warrants to the original purchaser for use of our products, that any part thereof which proves to be defective in material or workmanship under normal use within one year from date of installation, will be replaced free of charge. Labor to replace such parts is warranted for one year from installation. All warranty labor to be performed during regular working hours, with no overtime premium. All warranty service must be authorized by the factory and be performed by AVTEC s authorized service personnel. This warranty is limited to the United States and Canada. This warranty does not apply to any damage resulting from shipping, improper installation, accident, unauthorized alteration, local codes not previously brought to the attention of AVTEC, misuse, or abuse; and does not cover loss of food, other products or damage to equipment or property resulting from mechanical or electrical failure. AVTEC neither makes nor assumes and does not authorize any other person to assume any other obligation of liability in connection with its products other than that covered in this warranty. General All Avtec (Unified Brands) food service equipment is backed by some of the best warranties in the foodservice industry and by our professional staff of service technicians. Retain this manual for future reference. NOTICE: Due to a continuous program of product improvement, Avtec reserves the right to make changes in design and specifications without prior notice. NOTICE: Please read the entire manual carefully before installation. If certain recommended procedures are not followed, warranty claims will be denied. Product Information MODEL NUMBER: SERIAL NUMBER: INSTALLATION DATE: OM-SP VSP 3
4 Regulatory Information UL Avtec VSP Hoods UL File number MH2966 Southern Pride Smoker UL File number MH943 Verification of these UL file numbers can be found at Go to the certifications tab and type in the UL file number in the UL online certifications directory. IMC The 06 International Mechanical Code is referenced on the TTW VSP hood drawings Termination Location Exhaust outlets shall be located not less than 0 feet (3048 mm) horizontally from parts of the same or contiguous buildings, adjacent buildings, adjacent property lines and air intake openings into any building and shall be located not less than 0 feet (3048 mm) above the adjoining grade level. Exception Exhaust outlets shall terminate not less than 5 feet (524 mm) from parts of the same or contiguous building, an adjacent building, adjacent property line and air intake openings into a building where air from the exhaust outlet discharges away from such locations. NFPA-96 These exhaust hoods are intended for use in accordance with the Standard of the National Fire Protection Association for the Ventilation Control and Fire Protection of Commercial Cooking Operations. 4 OM-SP VSP
5 Option : Indoor Installation SYSTEM TO INCLUDE:. VENTILATION 2. 2-SPEED FAN (380CFM/00CFM) /2 HP, //60,.75 STATIC PRESSURE (DUCT RUNS WITH MORE THAN ONE ELBOW, CONSULT FACTORY FOR FAN SIZE) FOR WIRING, SEE ELECTRICAL CONNECTIONS ON PAGE. 3. CURB INCLUDED WITH VENTED EXTENSION AND HINGE KIT. NOTES:. OPTIONAL PITCH SHOWN, FLAT CURBS ARE STANDARD. 2. V//60 POWER STANDARD ON EXHAUST FAN. 3. FAN SIZED FOR DUCT RUN WITH ONE ELBOW. 4. FOR DUCT RUNS WITH MORE THAN ONE ELBOW, CONSULT FACTORY FOR FAN SIZE. OM-SP VSP 5
6 Option 2: Through the Wall Installation SYSTEM TO INCLUDE:. VENTILATION 2. 2-SPEED FAN (380CFM/00CFM) /2 HP, //60,.75 STATIC PRESSURE (DUCT RUNS WITH MORE THAN ONE ELBOW, CONSULT FACTORY FOR FAN SIZE) FOR WIRING, SEE ELECTRICAL CONNECTIONS ON PAGE. 3. CURB INCLUDED WITH VENTED EXTENSION AND HINGE KIT. NOTES:. IMPORTANT SMOKER NOTE: WHEN INSTALLING AN OVEN THROUGH a WALL CONSTRUCTED OF COMBUSTIBLE MATERIAL, PLEASE REFER TO UL LISTING (MH943) DURING INSTALLATION. OVEN MAY BE INSTALLED THROUGH WALL WITH ZERO CLEARANCE WHEN BBR KIT NO 99 PROVIDED. 2. OPTIONAL STAINLESS STEEL TRIM KIT FOR WALL INSTALLATION AVAILABLE FROM SOUTHERN PRIDE. 3. OPTIONAL PITCH SHOWN, FLAT CURBS ARE STANDARD. 6 OM-SP VSP
7 Option 3: Through the Wall Installation with Curb Assembly International Mechanical Code Termination Location Exception: Exhaust outlets shall terminate not less than 5 feet (524 mm) from parts of the same or contiguous building, an adjacent building, adjacent property line and air intake openings into a building where air from the exhaust outlet discharges away from such locations. SYSTEM TO INCLUDE:. VENTILATION 2. 2-SPEED FAN (380CFM/00CFM) /2 HP, //60,.75 STATIC PRESSURE (DUCT RUNS WITH MORE THAN ONE ELBOW, CONSULT FACTORY FOR FAN SIZE) FOR WIRING, SEE ELECTRICAL CONNECTIONS ON PAGE. 3. VSP TILTED CURB ASSEMBLY INCLUDED. NOTES:. IMPORTANT SMOKER NOTE: WHEN INSTALLING AN OVEN THROUGH a WALL CONSTRUCTED OF COMBUSTIBLE MATERIAL, PLEASE REFER TO UL LISTING (MH943) DURING INSTALLATION. OVEN MAY BE INSTALLED THROUGH WALL WITH ZERO CLEARANCE WHEN BBR KIT NO 99 PROVIDED. 2. OPTIONAL STAINLESS STEEL TRIM KIT FOR WALL INSTALLATION AVAILABLE FROM SOUTHERN PRIDE. 3. OPTIONAL PITCH SHOWN, FLAT CURBS ARE STANDARD. OM-SP VSP 7
8 Standard VSP Top Collar Installation Instructions Avtec VSP s sit directly on the Southern Pride Smokers.. Check all local codes prior to installation. Special requirements may be necessary depending upon building material construction. 2. Move crated hood to location of installation and very carefully uncrate hood. 3. Raise hood up and sit on the Southern Pride Smoker. Figure 4. Line up hood so it is pushed all the way back so the front tabs of the hood will be secured to smoker oven. (See Figures & 2) 5. Install with self-tapping stainless steel sheet metal screws. 6. Install grease filters into front of hood by sliding them into the filter channel built into the hood. THE DRAIN CONNECTION IS DESIGNED TO FACILITATE CLEANING AND MUST BE DIRECTED TO FRONT FLUE ON SMOKER SO CONDENSATION DRAINS INTO FLUE. Figure 2 8 OM-SP VSP
9 Rear Collar VSP Installation Instructions Exhaust Fan & Duct: When 2-speed exhaust fan is installed correctly, it will operate at a low CFM when oven doors are closed, and a high CFM when doors are open.. Check all local codes prior to installation. 2. All exhaust fans are supplied with a minimum 8 high metal curb, hinge kit, and grease box. 3. The exhaust fan curb should be installed directly above the hood if possible. Always maintain the shortest duct run possible. 4. Cut hole and seal exhaust fan curb to roof. 5. Place exhaust fan on curb. 6. Install hinges on exhaust fan cap and metal curb. Remember to leave ample room for fan to tilt back. Fan will remain in tilted back position. 7. Install grease collection box on side of fan that has grease tube discharge. 8. The exhaust duct must be constructed of gauge carbon steel or 8 gauge stainless steel. All seams must be fluid welded. 9. A duct transition should be provided below exhaust fan inlet. 0. The exhaust duct must be fluid welded to hood collar.. Make all necessary electrical connections and check fan for proper rotation. NOTE: Fan will exhaust air running in wrong direction. Refer to page. OM-SP VSP 9
10 Exhaust Fan & Duct for 400 Through the Wall Application (Option 3) Installation Instructions International Mechanical Code Termination Location Exception: Exhaust outlets shall terminate not less than 5 feet (524 mm) from parts of the same or contiguous building, an adjacent building, adjacent property line and air intake openings into a building where air from the exhaust outlet discharges away from such locations.. Check all codes prior to installation. 2. The exhaust fan curb should be installed directly on top of smoker. Connect the exhaust duct to the hood collar. Secure duct with supplied nuts and bolts. (See Figure below) 3. Secure exhaust fan curb assembly to the top of the smoker. Drive screws through flange of curb assembly in to edge of smoker. Only along the back edge of the smoker. Two screws minimum. Holes may have to be predrilled through flange. (See Figure below) 4. Install hinge kit on curb assembly and exhaust fan. (Provided by fan manufacturer). 5. Install grease collection box on side of fan that has grease tube discharge. 6. Make all necessary electrical connections and check fan for proper rotation. NOTE: Fan will exhaust air running in wrong direction. Refer to page. 0 OM-SP VSP
11 Electrical Connection for VSP Hood to 2-Speed Exhaust Fan NOTICE: It is suggested that a V outlet on a AMP breaker be supplied for oven and hood system. When 2-speed exhaust fan is installed correctly, it will operate at a low CFM when oven doors are closed and a high CFM when doors are open. Wiring for V/60C/P 2-Speed Fan Application SUPPLIED FROM OVEN: SUPPLIED FROM FAN: Black High Speed Black High Speed Red Low Speed Red Low Speed White Neutral White Neutral OM-SP VSP
12 Warranty Congratulations on your purchase of an Avtec brand piece of equipment. Unified Brands believes strongly in the products it builds and backs them with the best warranty in the industry. Standard with every unit comes the piece of mind that this unit has been thoroughly engineered, properly tested and manufactured to excruciating tolerances, by a manufacturer with over 30 years of industry presence. On top of that front end commitment, Unified Brands has a dedicated staff of certified technicians that monitor our own technical service hotline at to assist you with any questions or concerns that may arise after delivery of your new Avtec equipment. year parts replacement of any and all parts that are found defective in material or workmanship year labor reimbursement for any repairs that are caused by Avtec s use of defective material or workmanship (Repairs to be performed by a an Avtec Authorized Service Agent (ASA) at contracted rate) Warranty begins at the time of installation or 6 months from factory shipment, whichever occurs first. For warranty inquiries or questions regarding current ASAs please contact the Avtec technical support hotline at or visit the Avtec page of our web site at Items Not Covered Under Warranty Maintenance type of repairs such as routine cleaning, temperature adjustments, air balancing, clogged drains, unit leveling, and gasket replacement or cleaning. Repairs caused by abuse, freight damage, improper or incomplete installation, accidents, unauthorized alterations, and local codes not previously brought to the attention of the Avtec engineering department. Component failure due to inadequate power supply, gas supply or water supply, and water damage from cleaning procedures. Specification & Product Design Sanitation Requirements Cancellations Due to continued product improvement, specification and product design may change without notice. Such revisions do not entitle the buyer to additions, changes or replacemesnts for previously purchased equipment. Certain areas require specific sanitation requirements other than N.S.F. & U.L. standards. Unified Brands must be advised of these specifications before fabrication of equipment. In these special circumstances, a revised quotation may be required to cover additional costs. Failure to notify Unified Brands before fabrication holds the dealer accountable for all additional charges. Orders canceled prior to production scheduling entered into engineering/production and cancelled are subject to a cancellation charge (contact Customer Service for details). 2 OM-SP VSP
13 Warranty Storage Charges Unified Brands makes every effort to consistently meet our customers shipment expectations. If after the equipment has been fabricated, the customer requests delay in shipment, and warehousing is required: Equipment held for shipment at purchaser s request for a period 30 days beyond original delivery date specified will be invoiced and become immediately payable. Equipment held beyond 30 days after the original delivery date specified will also include storage charges. Shipping & Delivery Damages Returned Goods Installation Penalty Clauses Export Policy Unified Brands will attempt to comply to any shipping, routing or carrier request designated by dealer, but reserves the right to ship merchandise via any responsible carrier at the time equipment is ready for shipment. Unified Brands will not be held responsible for any carrier rate charges when the Dealer s requested carrier is used. Rate charges are entirely between the carrier and purchaser. Point of shipping shall be determined by Unified Brands (Weidman, MI / Jackson, Mississippi). At Dealer s request, Unified Brands will endeavor whenever practical to meet dealers request. Freight charges for Dealer requested carriers will be collect unless otherwise noted. All crating conforms to general motor carrier specifications. To avoid concealed damage, we recommend inspection of every carton upon receipt. In the event the item shows rough handling or visible damage, to minimize liability, a full inspection is necessary upon arrival. A notation must be placed on the freight bill and signed for by the truck driver. Appearance of damage will require removing the crate in the presence of the driver. Consignee is responsible for filing of freight claims when a clear delivery receipt is signed. Claims for damages must be filed immediately (within 0 days) by the consignee with the freight carrier. Retain all cartons and merchandise for inspection. Authorization for return must first be obtained from Unified Brands before returning any merchandise. Any returned goods shipment lacking the return authorization number will be refused, all additional freight costs to be borne by the returning party. Returned equipment must be shipped in original carton, freight prepaid and received in good conditions. Any returned merchandise is subject to a minimum handling charge (consult Customer Service for rate). Equipment installation is the responsibility of the dealer and/or their customer. Dealer penalty clauses, on their purchase order or contractually agreed to between the dealer and their clients are not binding on Unified Brands. Unified Brands does not accept orders subject to penalty clauses. This agreement supersedes any such clauses in dealer purchase orders. All quotations for export sales will be handled by Unified Brands export management organization. Contact Unified Brands customer support at for further details on export equipment. OM-SP VSP 3
14 Warranty Warranty Unified Brands warrants to the original purchaser for use of our products, that any part thereof which proves to be defective in material or workmanship under normal use within one year from date of installation, will be replaced free of charge. Labor to replace such parts is warranted for one year from installation. All warranty labor to be performed during regular working hours, with no overtime premium. All warranty service must be authorized by the factory and be performed by AVTEC s authorized service personnel. This warranty is limited to the United States and Canada. This warranty does not apply to any damage resulting from shipping, improper installation, accident, unauthorized alteration, local codes not previously brought to the attention of AVTEC, misuse, or abuse; and does not cover loss of food, other products or damage to equipment or property resulting from mechanical or electrical failure. AVTEC neither makes nor assumes and does not authorize any other person to assume any other obligation of liability in connection with its products other than that covered in this warranty. Safety Procedures Do not attempt to service this unit yourself as removing covers may cause unnecessary exposure to dangerous voltage. Never connect the unit to a power source while standing in water. Wet hands and wet floors should be avoided when connecting any electrical appliance to a power outlet. Fans may have multiple power connections. Make sure all fans are isolated from power prior to performing maintenance. Warranty Service Procedures Please have the following information before calling one of the service contacts: Serial Number. If Serial Number is not available, please call the Unified Brands Service Department at ext with the job site address. From this they may be able to get you the necessary reference numbers that our service department needs. Description of problem/service issue. Job site address, contact & phone number. Contact Information PLEASE CALL AVTEC SERVICE DEPARTMENT WITH ALL VSP SERVICE RELATED ISSUES! Unified Brands/Avtec Parts & Service Department Phone: , Fax: Dan Wixson Ext. 6469, dwixson@unifiedbrands.net Brian Zingler Ext. 6405, bzingler@unifiedbrands.net Scott Sandel Ext. 6442, scotts@unifiedbrands.net 4 OM-SP VSP
15 Ventilation Maintenance Guide Roof Top Systems- Make Up Air & Exhaust Fans. Air intake filters should be cleaned monthly or more often as conditions dictate. 2. Check all belts for slippage and tighten as necessary. 3. Clean exhaust fan interior and wheel as required to prevent accumulation of grease that could lead to a fire hazard. 4. Electrical connections should be inspected every six months. 5. Oil and/or grease all motors and bearings every six months. 6. If supplied, check and empty grease collection cup on outside of exhaust fan. Cleaning and Maintenance of Stainless Steel Hoods. Carefully wipe away gritty substances clinging to hood surface to avoid scratching. 2. Dilute ½ cup EVAC detergent with gallon warm water. 3. Soak a cloth in the water detergent solution, wring out excess. 4. Rub the cloth in the direction of the grain. 5. Wipe stainless steel dry with a clean cloth. 6. Reapply stainless steel polish. 7. Empty and clean grease drain and cups as needed per your application. 8. Filters should be cleaned in a dishwasher or soak sink as needed per your application. CAUTIONS DO NOT use steel wool (Brillo Pads), scrapers, or spatulas to clean hood! DO NOT use the following substances on or around the hood!. Chlorine or chlorine based substances. 2. Acids (e.g. mercuric chloride, ferric chloride). Vapors of the above substances can corrode stainless steel! OM-SP VSP 5
16 2 X. Diagrams ITEM APPROX. - HANGING WEIGHT 00 LENGTH WIDTH 49 TOTAL EXH. CFM 00 EXHAUST AIRFLOW EXH. RATE COLLAR(S) (LIN. FT.) F-B L-R CFM EXH. DUCT VELOCITY 00 S.P.-W.C." AT COLLAR HEIGHT WIDTH 2.50 CFM PER FILTERS FILTER FILTER NET MATERIAL VELOCITY FILTER AREA (FPM) (SQ.FT) SS ALUM VCR 2 SPEED FAN (NTS) WITH VENT EXTENSION AND FLAT ROOF CURB MAKE COOK OVEL(FPM) 840 SE 58% CUSTOMER NOTE FABRICATION AND INSTALLATION REQUIRED BY INSTALLING CONTRACTOR MODEL# 5 VCR WEIGHT(LBS) 76 VOL(CFM) /4" 22 /2 26 /2 SP(inwc).75 ELECTRICAL 5//60 34 / 23 CUSTOMER SUPPLIED DUCTWORK Ht 30 3/4 VENTS 4 SIDES GALAVINIZED STEEL " MIN " MIN Roof Opening PWR(HP).44 MOTOR ENCL ODP -SE Upblast Centrifugal Restaurant Exhaust Ventilator Roof Mounted Belt Drive Description Fan shall be a spun aluminum, roof mounted, belt driven, upblast centrifugal exhaust ventilator. Certifications Fan shall be listed by Underwriters Laboratories (UL 762) and UL listed for Canada (cul 762). Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. MHP.5 RPM 075 MOTOR RPM 725/40 SONES 2.55 DRIVE B NOTES Drive Loss(Low) = 9% 46" 7" VSP TOP DISCHARGE COLLAR ALUMINUM GREASE FILTERS GREASE TROUGH SLOPED TO MIDDLE GREASE AND CREOSOTE DRAIN /2" PIPE WITH ELBOW 0" 7.94" 7.997" " ATTACH TO OVEN WITH SELF TAPPING DRILLING SCREWS 8.05".973" SIDE SKIRTS REMOVABLE FOR SHIPPING REQUIRED FOR OPERATION SCREWED TO SIDE OF OVEN 32.00" SOUTHERN PRIDE SPX 300 SMOKER 47.75" " 63.05" 9" SECTION VIEW " 4.75" 39.25" 63" 9" 2" 2" PLAN VIEW EQUIPMENT DIMENSIONS ".625" ELEVATION VIEW The Southern Pride Oven Model SPX300 is a gas fired wood burning barbecue oven for restaurant and other commercial use. The gas and wood are burned in a common fire chamber and the products of combustion are passed through a separate chamber and are vented through a flue collar on front of the oven. Natural or L.P. - Gas is the primary fuel utilized for heating; wood is utilized as a secondary fuel for food flavoring. The SPX 300 is UL Certified(File MH943). The oven is totally enclosed.thermostatically controlled, and has no open flame. The model VSP-S-SPX300 Hood System (MH 2966) is intended for use with the Southern Pride Model SPX 300 smoker oven. The VSP hood is UL Listed and NSF certified and is listed specifically for use with the SPX 300 oven. The VSP-S-SPX300 is designed for through the wall (TTW) oven installations. This system is designed such that the exhaust fan operates at low air flow (380 CFM) during cooking operation and at high air flow (00 CFM) when the meat door is opened Electrical Connection for VSP Hood Two (2) Speed Exhaust Fan Note: Oven requires amp/vac single phase - 60 hz. breaker and a gas supply that provides a minimum of 50,000 BTU. SUPPLIED FROM OVEN SUPPLIED FROM FAN DATE QUOTE NUMBER ORDER NUMBER PROJECT NAME SHEET SOUTHERN PRIDE SPX 300 OVEN WITH VSP-S-SPX300 OM-SP VSP
17 2 X. Diagrams ITEM APPROX. - HANGING WEIGHT 30 LENGTH 52.3 WIDTH 49 TOTAL EXH. CFM 00 EXHAUST AIRFLOW EXH. RATE COLLAR(S) (LIN. FT.) F-B L-R CFM EXH. DUCT VELOCITY 00 S.P.-W.C." AT COLLAR HEIGHT WIDTH 3.50 CFM PER FILTERS FILTER FILTER NET MATERIAL VELOCITY FILTER AREA (FPM) (SQ.FT) SS ALUM VCR 2 SPEED FAN (NTS) WITH VENT EXTENSION AND FLAT ROOF CURB MAKE COOK CUSTOMER NOTE FABRICATION AND INSTALLATION REQUIRED BY INSTALLING CONTRACTOR MODEL# 5 VCR VOL(CFM) /4" 34 / 23 CUSTOMER SUPPLIED DUCTWORK 22 /2 26 /2 SP(inwc).75 Ht 30 3/4 VENTS 4 SIDES GALAVINIZED STEEL " MIN " MIN Roof Opening PWR(HP).44 Upblast Centrifugal Restaurant Exhaust Ventilator Roof Mounted Belt Drive Description Fan shall be a spun aluminum, roof mounted, belt driven, upblast centrifugal exhaust ventilator. Certifications Fan shall be listed by Underwriters Laboratories (UL 762) and UL listed for Canada (cul 762). Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. MHP.5 RPM 075 SONES 2.55 DRIVE B OVEL(FPM) 840 SE 58% WEIGHT(LBS) 76 ELECTRICAL 5//60 MOTOR ENCL ODP -SE MOTOR RPM 725/40 NOTES Drive Loss(Low) = 9% TOP DISCHARGE COLLAR VSP " ALUMINUM GREASE FILTERS GREASE TROUGH SLOPED TO MIDDLE 0" 7.94" 7.997" ATTACH TO OVEN WITH SELF TAPPING DRILLING SCREWS GREASE AND CREOSOTE DRAIN /2" PIPE WITH ELBOW.973" 32.00" SOUTHERN PRIDE SPK 500 SMOKER SIDE SKIRTS REMOVABLE FOR SHIPPING REQUIRED FOR OPERATION SCREWED TO SIDE OF OVEN " 65.55" SECTION VIEW 48.5" 7" " 9" 65.5".625" 9" " 54.8" " 26.88" 2" 2" PLAN VIEW EQUIPMENT DIMENSIONS " ELEVATION VIEW The Southern Pride Oven Model SPK500 is a gas fired wood burning barbecue oven for restaurant and other commercial use. The gas and wood are burned in a common fire chamber and the products of combustion are passed through a separate chamber and are vented through a flue collar on front of the oven. Natural or L.P. - Gas is the primary fuel utilized for heating; wood is utilized as a secondary fuel for food flavoring. The SPK500 is UL Certified(File MH943). The oven is totally enclosed.thermostatically controlled, and has no open flame. The model VSP-S-SPK500 Hood System (MH 2966) is intended for use with the Southern Pride Model SPK 500 smoker oven. The VSP hood is UL Listed and NSF certified and is listed specifically for use with the SPK 500 oven. The VSP-S-SPK500 is designed for through the wall (TTW) oven installations. This system is designed such that the exhaust fan operates at low air flow (380 CFM) during cooking operation and at high air flow (00 CFM) when the meat door is opened Electrical Connection for VSP Hood Two (2) Speed Exhaust Fan Note: Oven requires amp/vac single phase - 60 hz. breaker and a gas supply thatprovides a minimum of 75,000 BTU. SUPPLIED FROM OVEN SUPPLIED FROM FAN DATE QUOTE NUMBER ORDER NUMBER PROJECT NAME SHEET SOUTHERN PRIDE SPK 500 OVEN WITH VSP-S-SPK500 OM-SP VSP 7
18 2 X. Diagrams ITEM APPROX. - HANGING WEIGHT 00 LENGTH 33 WIDTH 49 TOTAL EXH. CFM 00 EXHAUST AIRFLOW EXH. RATE COLLAR(S) (LIN. FT.) F-B L-R CFM EXH. DUCT VELOCITY 00 S.P.-W.C." AT COLLAR HEIGHT WIDTH 2.50 CFM PER FILTERS FILTER FILTER NET MATERIAL VELOCITY FILTER AREA (FPM) (SQ.FT) SS ALUM VCR 2 SPEED FAN (NTS) WITH VENT EXTENSION AND FLAT ROOF CURB MAKE COOK CUSTOMER NOTE FABRICATION AND INSTALLATION REQUIRED BY INSTALLING CONTRACTOR MODEL# 5 VCR VOL(CFM) /4" 34 / 23 CUSTOMER SUPPLIED DUCTWORK 22 /2 26 /2 SP(inwc).75 Ht 30 3/4 VENTS 4 SIDES GALAVINIZED STEEL " MIN " MIN Roof Opening PWR(HP).44 Upblast Centrifugal Restaurant Exhaust Ventilator Roof Mounted Belt Drive Description Fan shall be a spun aluminum, roof mounted, belt driven, upblast centrifugal exhaust ventilator. Certifications Fan shall be listed by Underwriters Laboratories (UL 762) and UL listed for Canada (cul 762). Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. MHP.5 RPM 075 SONES 2.55 DRIVE B OVEL(FPM) 840 SE 58% WEIGHT(LBS) 76 ELECTRICAL 5//60 MOTOR ENCL ODP -SE MOTOR RPM 725/40 NOTES Drive Loss(Low) = 9% TOP DISCHARGE COLLAR ATTACH TO OVEN WITH SELF TAPPING DRILLING SCREWS VSP " ALUMINUM GREASE FILTERS GREASE TROUGH SLOPED TO MIDDLE 0" 7.94" 7.997" GREASE AND CREOSOTE DRAIN /2" PIPE WITH ELBOW.973" 32.00" SOUTHERN PRIDE XLR 600 SMOKER SIDE SKIRTS REMOVABLE FOR SHIPPING REQUIRED FOR OPERATION SCREWED TO SIDE OF OVEN 79.55" SECTION VIEW 62.56" " 7" 6" 5" 33.05".463" 2" 9" 2" PLAN VIEW EQUIPMENT DIMENSIONS ".625" ELEVATION VIEW The Southern Pride Oven Model XLR 600 is a gas fired wood burning barbecue oven for restaurant and other commercial use. The gas and wood are burned in a common fire chamber and the products of combustion are passed through a separate chamber and are vented through a flue collar on front of the oven. Natural or L.P. - Gas is the primary fuel utilized for heating; wood is utilized as a secondary fuel for food flavoring. The XLR 600 is UL Certified(File MH943). The oven is totally enclosed.thermostatically controlled, and has no open flame. The model VSP-S-XLR600 Hood System (MH 2966) is intended for use with the Southern Pride Model XLR 600 smoker oven. The VSP hood is UL Listed and NSF certified and is listed specifically for use with the XLR 600 oven. The VSP-S-XLR600 is designed for through the wall (TTW) oven installations. This system is designed such that the exhaust fan operates at low air flow (380 CFM) during cooking operation and at high air flow (00 CFM) when the meat door is opened Electrical Connection for VSP Hood Two (2) Speed Exhaust Fan Note: Oven requires amp/vac single phase - 60 hz. breaker and a gas supply thatprovides a minimum of 25,000 BTU. SUPPLIED FROM OVEN SUPPLIED FROM FAN DATE QUOTE NUMBER ORDER NUMBER PROJECT NAME SHEET SOUTHERN PRIDE XLR 600 OVEN WITH VSP-S-XLR600 8 OM-SP VSP
19 2 X. Diagrams ITEM APPROX. - HANGING WEIGHT 30 5 VCR 2 SPEED FAN (NTS) WITH VENT EXTENSION AND FLAT ROOF CURB MAKE COOK OVEL(FPM) 840 LENGTH 52.4 WIDTH 49 TOTAL EXH. CFM 00 EXHAUST AIRFLOW EXH. RATE COLLAR(S) (LIN. FT.) F-B L-R CFM EXH. DUCT VELOCITY 57 S.P.-W.C." AT COLLAR HEIGHT WIDTH 3.50 CFM PER FILTERS FILTER FILTER NET MATERIAL VELOCITY FILTER AREA (FPM) (SQ.FT) SS ALUM CUSTOMER NOTE 34 / 30 3/4 Upblast Centrifugal Restaurant Exhaust Ventilator Roof Mounted Belt Drive FABRICATION AND INSTALLATION REQUIRED BY INSTALLING CONTRACTOR MODEL# 5 VCR VOL(CFM) /4" 23 CUSTOMER SUPPLIED DUCTWORK 22 /2 26 /2 SP(inwc).75 Ht VENTS 4 SIDES GALAVINIZED STEEL " MIN " MIN Roof Opening PWR(HP).44 Description Fan shall be a spun aluminum, roof mounted, belt driven, upblast centrifugal exhaust ventilator. Certifications Fan shall be listed by Underwriters Laboratories (UL 762) and UL listed for Canada (cul 762). Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. MHP.5 RPM 075 SONES 2.55 DRIVE B SE 58% WEIGHT(LBS) 76 ELECTRICAL 5//60 MOTOR ENCL ODP -SE MOTOR RPM 725/40 NOTES Drive Loss(Low) = 9% STANDARD DISCHARGE COLLAR VSP 65.79" ALUMINUM GREASE FILTERS GREASE TROUGH SLOPED TO MIDDLE 0" 8" 8" GREASE AND CREOSOTE DRAIN /2" PIPE WITH ELBOW 2" ATTACH TO OVEN WITH SELF TAPPING DRILLING SCREWS SOUTHERN PRIDE SP 750 SMOKER SIDE SKIRTS REMOVABLE FOR SHIPPING REQUIRED FOR OPERATION SCREWED TO SIDE OF OVEN 82.75" SECTION VIEW 65.87" 95" 7" 6.75".25" 82.75".63" 9" 54.8" 52.3" 2" 2" 26.5" PLAN VIEW EQUIPMENT DIMENSIONS " ELEVATION VIEW The Southern Pride Oven Model SP 750 is a gas fired wood burning barbecue oven for restaurant and other commercial use. The gas and wood are burned in a common fire chamber and the products of combustion are passed through a separate chamber and are vented through a flue collar on front of the oven. Natural or L.P. - Gas is the primary fuel utilized for heating; wood is utilized as a secondary fuel for food flavoring. The SP 750 is UL Certified(File MH943). The oven is totally enclosed.thermostatically controlled, and has no open flame. The model VSP-S-SP750 Hood System (MH 2966) is intended for use with the Southern Pride Model SP 750 smoker oven. The VSP hood is UL Listed and NSF certified and is listed specifically for use with the XLR 600 oven. The VSP-S-SP750 is designed for through the wall (TTW) oven installations. This system is designed such that the exhaust fan operates at low air flow (380 CFM) during cooking operation and at high air flow (00 CFM) when the meat door is opened Electrical Connection for VSP Hood Two (2) Speed Exhaust Fan Note: Oven requires amp/vac single phase - 60 hz. breaker and a gas supply thatprovides a minimum of 50,000 BTU. SUPPLIED FROM OVEN SUPPLIED FROM FAN DATE QUOTE NUMBER ORDER NUMBER PROJECT NAME SHEET SOUTHERN PRIDE SP 750 OVEN WITH VSP-S-SP750 OM-SP VSP 9
20 2 X. Diagrams ITEM APPROX. - HANGING WEIGHT 30 LENGTH 52.4 WIDTH 49 TOTAL EXH. CFM 00 EXHAUST AIRFLOW EXH. RATE COLLAR(S) (LIN. FT.) F-B L-R CFM EXH. DUCT VELOCITY 00 S.P.-W.C." AT COLLAR HEIGHT WIDTH 3.50 CFM PER FILTERS FILTER FILTER NET MATERIAL VELOCITY FILTER AREA (FPM) (SQ.FT) SS ALUM VCR 2 SPEED FAN (NTS) WITH VENT EXTENSION AND FLAT ROOF CURB MAKE COOK CUSTOMER NOTE FABRICATION AND INSTALLATION REQUIRED BY INSTALLING CONTRACTOR MODEL# 5 VCR VOL(CFM) /4" 34 / 23 CUSTOMER SUPPLIED DUCTWORK 22 /2 26 /2 SP(inwc).75 Ht 30 3/4 VENTS 4 SIDES GALAVINIZED STEEL " MIN " MIN Roof Opening PWR(HP).44 Upblast Centrifugal Restaurant Exhaust Ventilator Roof Mounted Belt Drive Description Fan shall be a spun aluminum, roof mounted, belt driven, upblast centrifugal exhaust ventilator. Certifications Fan shall be listed by Underwriters Laboratories (UL 762) and UL listed for Canada (cul 762). Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. MHP.5 RPM 075 SONES 2.55 DRIVE B OVEL(FPM) 840 SE 58% WEIGHT(LBS) 76 ELECTRICAL 5//60 MOTOR ENCL ODP -SE MOTOR RPM 725/40 NOTES Drive Loss(Low) = 9% STANDARD DISCHARGE COLLAR VSP ALUMINUM GREASE FILTERS GREASE TROUGH SLOPED TO MIDDLE 0" GREASE AND CREOSOTE DRAIN /2" PIPE WITH ELBOW 8" 8" 2" 7.59" ATTACH TO OVEN WITH SELF TAPPING DRILLING SCREWS SOUTHERN PRIDE SP 000 SMOKER SIDE SKIRTS REMOVABLE FOR SHIPPING REQUIRED FOR OPERATION SCREWED TO SIDE OF OVEN 88.55" SECTION VIEW 7.62" 95" 7" 6.75".25" 88.5".63" 9" 62.27" 54.8" 52.43" 2" 2" PLAN VIEW EQUIPMENT DIMENSIONS " ELEVATION VIEW The Southern Pride Oven Model SP 000 is a gas fired wood burning barbecue oven for restaurant and other commercial use. The gas and wood are burned in a common fire chamber and the products of combustion are passed through a separate chamber and are vented through a flue collar on front of the oven. Natural or L.P. - Gas is the primary fuel utilized for heating; wood is utilized as a secondary fuel for food flavoring. The SP 000 is UL Certified(File MH943). The oven is totally enclosed.thermostatically controlled, and has no open flame. The model VSP-S-SP00 Hood System (MH 2966) is intended for use with the Southern Pride Model SP 000 smoker oven. The VSP hood is UL Listed and NSF certified and is listed specifically for use with the XLR 000 oven. The VSP-S-SP000 is designed for through the wall (TTW) oven installations. This system is designed such that the exhaust fan operates at low air flow (380 CFM) during cooking operation and at high air flow (00 CFM) when the meat door is opened Electrical Connection for VSP Hood Two (2) Speed Exhaust Fan Note: Oven requires amp/vac single phase - 60 hz. breaker and a gas supply thatprovides a minimum of 50,000 BTU. SUPPLIED FROM OVEN SUPPLIED FROM FAN DATE QUOTE NUMBER ORDER NUMBER PROJECT NAME SHEET SOUTHERN PRIDE SP 000 OVEN WITH VSP-S-SP000 OM-SP VSP
21 2 X X. Diagrams ITEM APPROX. - HANGING WEIGHT 2 LENGTH 55.7 WIDTH 49 TOTAL EXH. CFM 00 EXHAUST AIRFLOW EXH. RATE COLLAR(S) (LIN. FT.) F-B L-R CFM EXH. DUCT VELOCITY 00 S.P.-W.C." AT COLLAR HEIGHT WIDTH 2.50 CFM PER FILTERS FILTER FILTER NET MATERIAL VELOCITY FILTER AREA (FPM) (SQ.FT) SS ALUM VCR 2 SPEED FAN (NTS) WITH VENT EXTENSION AND FLAT ROOF CURB MAKE COOK CUSTOMER NOTE FABRICATION AND INSTALLATION REQUIRED BY INSTALLING CONTRACTOR MODEL# 5 VCR VOL(CFM) /4" 34 / 23 CUSTOMER SUPPLIED DUCTWORK 22 /2 26 /2 SP(inwc).75 Ht VENTS 4 SIDES GALAVINIZED STEEL " MIN " MIN Roof Opening PWR(HP) /4 Upblast Centrifugal Restaurant Exhaust Ventilator Roof Mounted Belt Drive Description Fan shall be a spun aluminum, roof mounted, belt driven, upblast centrifugal exhaust ventilator. Certifications Fan shall be listed by Underwriters Laboratories (UL 762) and UL listed for Canada (cul 762). Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. MHP.5 RPM 075 SONES 2.55 DRIVE B OVEL(FPM) 840 SE 58% WEIGHT(LBS) 76 ELECTRICAL 5//60 MOTOR ENCL ODP -SE MOTOR RPM 725/40 NOTES Drive Loss(Low) = 9% " VSP TOP DISCHARGE COLLAR.5" ALUMINUM GREASE FILTERS GREASE TROUGH SLOPED TO MIDDLE 0" 7.94" 7.997" ATTACH TO OVEN WITH SELF TAPPING DRILLING SCREWS.973" GREASE AND CREOSOTE DRAIN /2" PIPE WITH ELBOW 32.00" SIDE SKIRTS REMOVABLE FOR SHIPPING REQUIRED FOR OPERATION SCREWED TO SIDE OF OVEN SOUTHERN PRIDE XLR 400 SMOKER 00.55" SECTION VIEW 83.5" 83.5" 00.5" 7" 9.05" 75.5" 8".625" 9" 55.8" " 2" 2" PLAN VIEW EQUIPMENT DIMENSIONS " Southern PRIDE ELEVATION VIEW The Southern Pride Oven Model XLR400 is a gas fired wood burning barbecue oven for restaurant and other commercial use. The gas and wood are burned in a common fire chamber and the products of combustion are passed through a separate chamber and are vented through a flue collar on front of the oven. Natural or L.P. - Gas is the primary fuel utilized for heating; wood is utilized as a secondary fuel for food flavoring. The XLR400 is UL Certified(File MH943). The oven is totally enclosed.thermostatically controlled, and has no open flame. The model VSP-S-XLR400 Hood System (MH 2966) is intended for use with the Southern Pride Model XLR400 smoker oven. The VSP hood is UL Listed and NSF certified and is listed specifically for use with the XLR400 oven. The VSP-S-XLR400 is designed for through the wall (TTW) oven installations. This system is designed such that the exhaust fan operates at low air flow (380 CFM) during cooking operation and at high air flow (00 CFM) when the meat door is opened Electrical Connection for VSP Hood Two (2) Speed Exhaust Fan Note: Oven requires amp/vac single phase - 60 hz. breaker and a gas supply thatprovides a minimum of 25,000 BTU. SUPPLIED FROM OVEN SUPPLIED FROM FAN DATE QUOTE NUMBER ORDER NUMBER PROJECT NAME SHEET SOUTHERN PRIDE XLR 400 OVEN WITH VSP-S-XLR400 OM-SP VSP 2
22 2 X. Diagrams ITEM APPROX. - HANGING WEIGHT 00 LENGTH 34.3 WIDTH 49 TOTAL EXH. CFM 00 EXHAUST AIRFLOW EXH. RATE COLLAR(S) (LIN. FT.) F-B L-R CFM EXH. DUCT VELOCITY 57 S.P.-W.C." AT COLLAR HEIGHT WIDTH 2.50 CFM PER FILTERS FILTER FILTER NET MATERIAL VELOCITY FILTER AREA (FPM) (SQ.FT) SS ALUM VCR 2 SPEED FAN (NTS) WITH VENT EXTENSION AND FLAT ROOF CURB MAKE COOK OVEL(FPM) 840 SE 58% CUSTOMER NOTE FABRICATION AND INSTALLATION REQUIRED BY INSTALLING CONTRACTOR MODEL# 5 VCR WEIGHT(LBS) 76 VOL(CFM) /4" 22 /2 26 /2 SP(inwc).75 ELECTRICAL 5//60 34 / 23 CUSTOMER SUPPLIED DUCTWORK Ht 30 3/4 VENTS 4 SIDES GALAVINIZED STEEL " MIN " MIN Roof Opening PWR(HP).44 MOTOR ENCL ODP -SE Upblast Centrifugal Restaurant Exhaust Ventilator Roof Mounted Belt Drive Description Fan shall be a spun aluminum, roof mounted, belt driven, upblast centrifugal exhaust ventilator. Certifications Fan shall be listed by Underwriters Laboratories (UL 762) and UL listed for Canada (cul 762). Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. MHP.5 RPM 075 MOTOR RPM 725/40 SONES 2.55 DRIVE B NOTES Drive Loss(Low) = 9% 46" 7" VSP REAR DISCHARGE COLLAR ALUMINUM GREASE FILTERS GREASE TROUGH SLOPED TO MIDDLE GREASE AND CREOSOTE DRAIN /2" PIPE WITH ELBOW 45.96" 0" 7.94" 0" 8" 9" 8.0".97" ATTACH TO OVEN WITH SELF TAPPING DRILLING SCREWS SIDE SKIRTS REMOVABLE FOR SHIPPING REQUIRED FOR OPERATION SCREWED TO SIDE OF OVEN SOUTHERN PRIDE SPX 300 SMOKER 47.75" 84.76" 63.05" 9" SECTION VIEW 63".63" 49.22" 4.75" 39.25" 4" 9" 9.6" PLAN VIEW EQUIPMENT DIMENSIONS " ELEVATION VIEW The Southern Pride Oven Model SPX300 is a gas fired wood burning barbecue oven for restaurant and other commercial use. The gas and wood are burned in a common fire chamber and the products of combustion are passed through a separate chamber and are vented through a flue collar on front of the oven. Natural or L.P. - Gas is the primary fuel utilized for heating; wood is utilized as a secondary fuel for food flavoring. The SPX 300 is UL Certified(File MH943). The oven is totally enclosed.thermostatically controlled, and has no open flame. The model VSP-R-SPX300 Hood System (MH 2966) is intended for use with the Southern Pride Model SPX 300 smoker oven. The VSP hood is UL Listed and NSF certified and is listed specifically for use with the SPX 300 oven. The VSP-R-SPX300 is designed for through the wall (TTW) oven installations. This system is designed such that the exhaust fan operates at low air flow (380 CFM) during cooking operation and at high air flow (00 CFM) when the meat door is opened Electrical Connection for VSP Hood Two (2) Speed Exhaust Fan Note: Oven requires amp/vac single phase - 60 hz. breaker and a gas supply thatprovides a minimum of 50,000 BTU. SUPPLIED FROM OVEN SUPPLIED FROM FAN DATE QUOTE NUMBER ORDER NUMBER PROJECT NAME SHEET SOUTHERN PRIDE SPX 300 OVEN WITH VSP-R-SPX OM-SP VSP
23 2 X. Diagrams ITEM APPROX. - HANGING WEIGHT 30 LENGTH 52.3 WIDTH 49 TOTAL EXH. CFM 00 EXHAUST AIRFLOW EXH. RATE COLLAR(S) (LIN. FT.) F-B L-R CFM EXH. DUCT VELOCITY 57 S.P.-W.C." AT COLLAR HEIGHT WIDTH 3.50 CFM PER FILTERS FILTER FILTER NET MATERIAL VELOCITY FILTER AREA (FPM) (SQ.FT) SS ALUM VCR 2 SPEED FAN (NTS) WITH VENT EXTENSION AND FLAT ROOF CURB MAKE COOK CUSTOMER NOTE FABRICATION AND INSTALLATION REQUIRED BY INSTALLING CONTRACTOR MODEL# 5 VCR VOL(CFM) /4" 34 / 23 CUSTOMER SUPPLIED DUCTWORK 22 /2 26 /2 SP(inwc).75 Ht 30 3/4 VENTS 4 SIDES GALAVINIZED STEEL " MIN " MIN Roof Opening PWR(HP).44 Upblast Centrifugal Restaurant Exhaust Ventilator Roof Mounted Belt Drive Description Fan shall be a spun aluminum, roof mounted, belt driven, upblast centrifugal exhaust ventilator. Certifications Fan shall be listed by Underwriters Laboratories (UL 762) and UL listed for Canada (cul 762). Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. MHP.5 RPM 075 SONES 2.55 DRIVE B OVEL(FPM) 840 SE 58% WEIGHT(LBS) 76 ELECTRICAL 5//60 MOTOR ENCL ODP -SE MOTOR RPM 725/40 NOTES Drive Loss(Low) = 9% REAR DISCHARGE COLLAR VSP 48.59" ALUMINUM GREASE FILTERS GREASE TROUGH SLOPED TO MIDDLE 0" 7.94" 0" 8" 9" GREASE AND CREOSOTE DRAIN /2" PIPE WITH ELBOW.97" ATTACH TO OVEN WITH SELF TAPPING DRILLING SCREWS SOUTHERN PRIDE SPK 500 SMOKER SIDE SKIRTS REMOVABLE FOR SHIPPING REQUIRED FOR OPERATION SCREWED TO SIDE OF OVEN 65.55" SECTION VIEW 48.5" 90.43" 7" 52.37" " 65.5".63" 62.27" 54.8" 52.43" 26.9" 4" 26.9" PLAN VIEW EQUIPMENT DIMENSIONS " ELEVATION VIEW The Southern Pride Oven Model SPK500 is a gas fired wood burning barbecue oven for restaurant and other commercial use. The gas and wood are burned in a common fire chamber and the products of combustion are passed through a separate chamber and are vented through a flue collar on front of the oven. Natural or L.P. - Gas is the primary fuel utilized for heating; wood is utilized as a secondary fuel for food flavoring. The SPK500 is UL Certified(File MH943). The oven is totally enclosed.thermostatically controlled, and has no open flame. The model VSP-R-SPK500 Hood System (MH 2966) is intended for use with the Southern Pride Model SPK 500 smoker oven. The VSP hood is UL Listed and NSF certified and is listed specifically for use with the SPK 500 oven. The VSP-R-SPK500 is designed for through the wall (TTW) oven installations. This system is designed such that the exhaust fan operates at low air flow (380 CFM) during cooking operation and at high air flow (00 CFM) when the meat door is opened Electrical Connection for VSP Hood Two (2) Speed Exhaust Fan Note: Oven requires amp/vac single phase - 60 hz. breaker and a gas supply thatprovides a minimum of 75,000 BTU. SUPPLIED FROM OVEN SUPPLIED FROM FAN DATE QUOTE NUMBER ORDER NUMBER PROJECT NAME SHEET SOUTHERN PRIDE SPK 500 OVEN WITH VSP-R-SPK500 OM-SP VSP 23
24 2 X. Diagrams ITEM APPROX. - HANGING WEIGHT 00 LENGTH 33 WIDTH 49 TOTAL EXH. CFM 00 EXHAUST AIRFLOW EXH. RATE COLLAR(S) (LIN. FT.) F-B L-R CFM EXH. DUCT VELOCITY 57 S.P.-W.C." AT COLLAR HEIGHT WIDTH 2.50 CFM PER FILTERS FILTER FILTER NET MATERIAL VELOCITY FILTER AREA (FPM) (SQ.FT) SS ALUM VCR 2 SPEED FAN (NTS) WITH VENT EXTENSION AND FLAT ROOF CURB MAKE COOK CUSTOMER NOTE FABRICATION AND INSTALLATION REQUIRED BY INSTALLING CONTRACTOR MODEL# 5 VCR VOL(CFM) /4" 34 / 23 CUSTOMER SUPPLIED DUCTWORK 22 /2 26 /2 SP(inwc).75 Ht 30 3/4 VENTS 4 SIDES GALAVINIZED STEEL " MIN " MIN Roof Opening PWR(HP).44 Upblast Centrifugal Restaurant Exhaust Ventilator Roof Mounted Belt Drive Description Fan shall be a spun aluminum, roof mounted, belt driven, upblast centrifugal exhaust ventilator. Certifications Fan shall be listed by Underwriters Laboratories (UL 762) and UL listed for Canada (cul 762). Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. MHP.5 RPM 075 SONES 2.55 DRIVE B OVEL(FPM) 840 SE 58% WEIGHT(LBS) 76 ELECTRICAL 5//60 MOTOR ENCL ODP -SE MOTOR RPM 725/40 NOTES Drive Loss(Low) = 9% VSP REAR DISCHARGE COLLAR ALUMINUM GREASE FILTERS GREASE TROUGH SLOPED TO MIDDLE 0" 8" 9" 8" 62.59" GREASE AND CREOSOTE DRAIN /2" PIPE WITH ELBOW 2" SOUTHERN PRIDE XLR 600 SMOKER ATTACH TO OVEN WITH SELF TAPPING DRILLING SCREWS SIDE SKIRTS REMOVABLE FOR SHIPPING REQUIRED FOR OPERATION SCREWED TO SIDE OF OVEN 79.55" SECTION VIEW 62.56" 93" 7" 6" 5" 33" 4".5" PLAN VIEW EQUIPMENT DIMENSIONS. 33".63" ELEVATION VIEW The Southern Pride Oven Model XLR 600 is a gas fired wood burning barbecue oven for restaurant and other commercial use. The gas and wood are burned in a common fire chamber and the products of combustion are passed through a separate chamber and are vented through a flue collar on front of the oven. Natural or L.P. - Gas is the primary fuel utilized for heating; wood is utilized as a secondary fuel for food flavoring. The XLR 600 is UL Certified(File MH943). The oven is totally enclosed.thermostatically controlled, and has no open flame. The model VSP-R-XLR600 Hood System (MH 2966) is intended for use with the Southern Pride Model XLR 600 smoker oven. The VSP hood is UL Listed and NSF certified and is listed specifically for use with the XLR 600 oven. The VSP-R-XLR600 is designed for through the wall (TTW) oven installations. This system is designed such that the exhaust fan operates at low air flow (380 CFM) during cooking operation and at high air flow (00 CFM) when the meat door is opened Electrical Connection for VSP Hood Two (2) Speed Exhaust Fan Note: Oven requires amp/vac single phase - 60 hz. breaker and a gas supply thatprovides a minimum of 25,000 BTU. SUPPLIED FROM OVEN SUPPLIED FROM FAN DATE QUOTE NUMBER ORDER NUMBER PROJECT NAME SHEET SOUTHERN PRIDE XLR 600 OVEN WITH VSP-R-XLR OM-SP VSP
25 2 X. Diagrams ITEM APPROX. - HANGING WEIGHT 30 5 VCR 2 SPEED FAN (NTS) WITH VENT EXTENSION AND FLAT ROOF CURB MAKE COOK OVEL(FPM) 840 LENGTH 52.4 WIDTH 49 TOTAL EXH. CFM 00 EXHAUST AIRFLOW EXH. RATE COLLAR(S) (LIN. FT.) F-B L-R CFM EXH. DUCT VELOCITY 57 S.P.-W.C." AT COLLAR HEIGHT WIDTH 3.50 CFM PER FILTERS FILTER FILTER NET MATERIAL VELOCITY FILTER AREA (FPM) (SQ.FT) SS ALUM CUSTOMER NOTE 34 / 30 3/4 Upblast Centrifugal Restaurant Exhaust Ventilator Roof Mounted Belt Drive FABRICATION AND INSTALLATION REQUIRED BY INSTALLING CONTRACTOR MODEL# 5 VCR VOL(CFM) /4" 23 CUSTOMER SUPPLIED DUCTWORK 22 /2 26 /2 SP(inwc).75 Ht VENTS 4 SIDES GALAVINIZED STEEL " MIN " MIN Roof Opening PWR(HP).44 Description Fan shall be a spun aluminum, roof mounted, belt driven, upblast centrifugal exhaust ventilator. Certifications Fan shall be listed by Underwriters Laboratories (UL 762) and UL listed for Canada (cul 762). Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. MHP.5 RPM 075 SONES 2.55 DRIVE B SE 58% WEIGHT(LBS) 76 ELECTRICAL 5//60 MOTOR ENCL ODP -SE MOTOR RPM 725/40 NOTES Drive Loss(Low) = 9% REAR DISCHARGE COLLAR VSP 65.79" ALUMINUM GREASE FILTERS GREASE TROUGH SLOPED TO MIDDLE 0" 9" 8" 8" GREASE AND CREOSOTE DRAIN /2" PIPE WITH ELBOW 2" ATTACH TO OVEN WITH SELF TAPPING DRILLING SCREWS SOUTHERN PRIDE SP 750 SMOKER SIDE SKIRTS REMOVABLE FOR SHIPPING REQUIRED FOR OPERATION SCREWED TO SIDE OF OVEN 82.75" SECTION VIEW 65.87" 95" 7" 6.75".25" 82.75".63" 54.8" 52.3" 4" 26.4" PLAN VIEW EQUIPMENT DIMENSIONS " ELEVATION VIEW The Southern Pride Oven Model SP 750 is a gas fired wood burning barbecue oven for restaurant and other commercial use. The gas and wood are burned in a common fire chamber and the products of combustion are passed through a separate chamber and are vented through a flue collar on front of the oven. Natural or L.P. - Gas is the primary fuel utilized for heating; wood is utilized as a secondary fuel for food flavoring. The SP 750 is UL Certified(File MH943). The oven is totally enclosed.thermostatically controlled, and has no open flame. The model VSP-S-SP750 Hood System (MH 2966) is intended for use with the Southern Pride Model SP 750 smoker oven. The VSP hood is UL Listed and NSF certified and is listed specifically for use with the XLR 600 oven. The VSP-S-SP750 is designed for through the wall (TTW) oven installations. This system is designed such that the exhaust fan operates at low air flow (380 CFM) during cooking operation and at high air flow (00 CFM) when the meat door is opened Electrical Connection for VSP Hood Two (2) Speed Exhaust Fan Note: Oven requires amp/vac single phase - 60 hz. breaker and a gas supply thatprovides a minimum of 50,000 BTU. SUPPLIED FROM OVEN SUPPLIED FROM FAN DATE QUOTE NUMBER ORDER NUMBER PROJECT NAME SHEET SOUTHERN PRIDE SP 750 OVEN WITH VSP-R-SP750 OM-SP VSP 25
26 2 X. Diagrams ITEM APPROX. - HANGING WEIGHT 30 LENGTH 52.4 WIDTH 49 TOTAL EXH. CFM 00 EXHAUST AIRFLOW EXH. RATE COLLAR(S) (LIN. FT.) F-B L-R CFM EXH. DUCT VELOCITY 57 S.P.-W.C." AT COLLAR HEIGHT WIDTH 3.50 CFM PER FILTERS FILTER FILTER NET MATERIAL VELOCITY FILTER AREA (FPM) (SQ.FT) SS ALUM VCR 2 SPEED FAN (NTS) WITH VENT EXTENSION AND FLAT ROOF CURB MAKE COOK CUSTOMER NOTE FABRICATION AND INSTALLATION REQUIRED BY INSTALLING CONTRACTOR MODEL# 5 VCR VOL(CFM) /4" 34 / 23 CUSTOMER SUPPLIED DUCTWORK 22 /2 26 /2 SP(inwc).75 Ht 30 3/4 VENTS 4 SIDES GALAVINIZED STEEL " MIN " MIN Roof Opening PWR(HP).44 Upblast Centrifugal Restaurant Exhaust Ventilator Roof Mounted Belt Drive Description Fan shall be a spun aluminum, roof mounted, belt driven, upblast centrifugal exhaust ventilator. Certifications Fan shall be listed by Underwriters Laboratories (UL 762) and UL listed for Canada (cul 762). Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. MHP.5 RPM 075 SONES 2.55 DRIVE B OVEL(FPM) 840 SE 58% WEIGHT(LBS) 76 ELECTRICAL 5//60 MOTOR ENCL ODP -SE MOTOR RPM 725/40 NOTES Drive Loss(Low) = 9% REAR DISCHARGE COLLAR VSP ALUMINUM GREASE FILTERS GREASE TROUGH SLOPED TO MIDDLE 0" GREASE AND CREOSOTE DRAIN /2" PIPE WITH ELBOW 8" 8" 9" 2" 7.59" ATTACH TO OVEN WITH SELF TAPPING DRILLING SCREWS SOUTHERN PRIDE SP 000 SMOKER SIDE SKIRTS REMOVABLE FOR SHIPPING REQUIRED FOR OPERATION SCREWED TO SIDE OF OVEN 88.55" SECTION VIEW 7.62" 95" 7" 6.75".25" 88.5".63" 62.27" 54.8" 52.43" 4" 26.22" PLAN VIEW EQUIPMENT DIMENSIONS " ELEVATION VIEW The Southern Pride Oven Model SP 000 is a gas fired wood burning barbecue oven for restaurant and other commercial use. The gas and wood are burned in a common fire chamber and the products of combustion are passed through a separate chamber and are vented through a flue collar on front of the oven. Natural or L.P. - Gas is the primary fuel utilized for heating; wood is utilized as a secondary fuel for food flavoring. The SP 000 is UL Certified(File MH943). The oven is totally enclosed.thermostatically controlled, and has no open flame. The model VSP-R-SP00 Hood System (MH 2966) is intended for use with the Southern Pride Model SP 000 smoker oven. The VSP hood is UL Listed and NSF certified and is listed specifically for use with the XLR 000 oven. The VSP-R-SP000 is designed for through the wall (TTW) oven installations. This system is designed such that the exhaust fan operates at low air flow (380 CFM) during cooking operation and at high air flow (00 CFM) when the meat door is opened Electrical Connection for VSP Hood Two (2) Speed Exhaust Fan Note: Oven requires amp/vac single phase - 60 hz. breaker and a gas supply thatprovides a minimum of 50,000 BTU. SUPPLIED FROM OVEN SUPPLIED FROM FAN DATE QUOTE NUMBER ORDER NUMBER PROJECT NAME SHEET SOUTHERN PRIDE SP 000 OVEN WITH VSP-R-SP OM-SP VSP
MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)
C US FILE#:MH48178 MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS 78401 PH: (361)884-9800 WWW.JEANSRESTAURANTSUPPLY.COM UL Standard for Safety for Exhaust Hoods for
More informationBX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:
BX600 Innovation by Design - Since 1991 CLASSIC ColleCtion Insert Cyclone s newest insert is discreet and quiet yet bold and powerful enough to leave a distinct impression. Powered at 600 CFM and fitted
More informationOperation Maintenance. Mobile Oil Caddy
Mobile Oil Caddy Operation Maintenance W164 N9221 Water Street P.O. Box 450 Menomonee Falls, Wisconsin 53052-0450 USA PHONE: 262.251.3800 800.558.8744 usa/canada FAX: 262.251.7067 800.329.8744 u.s.a. only
More informationMODEL CDB8 INSTALLATION INSTRUCTIONS
REV 0417 TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com SUITABLE FOR SIDE WALL OR
More informationINSTALLATION, OPERATION & MAINTENANCE AVANTCO SERIES 177AG OWNER S MANUAL
INSTALLATION, OPERATION & MAINTENANCE AVANTCO SERIES 177AG OWNER S MANUAL Manual Griddles: Radiant Charbroilers: Hot Plates: 177AG24MG 177AG36MG 177AG24RC 177AG36RC 177AGR212 All equipment manufactured
More informationUser s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.
www.windsterhood.com User s Manual WS-63TB36SS WS-63TB42SS ISLAND SERIES NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed
More informationUSER MANUAL Gas Countertop Charbroilers
Gas Countertop Charbroilers REVISED 2/209 382799 LAVA BRIQUETTE MODELS: 35CLCPG5NL, 35CLCPG24NL, 35CLCPG36NL, 35CLCPG48NL, 35CLCPG60NL, 35CLCPG72NL Congratulations on your purchase of Cooking Performance
More informationProfessional Warming Drawer and Warming Drawer Cabinet
Professional Warming Drawer and Warming Drawer Cabinet Care & Use/Installation Instructions Models: (C)VQEWD5300SS (C)VQEWD5420SS IMPORTANT SAFETY INSTRUCTIONS WARNING: Read this manual carefully and completely
More informationREAD AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:
DANVER INSTALLATION INSTRUCTIONS & USE & CARE GUIDE DANVER DOHC Series Range Hood 1300 CFM DOHC Séries Models: 36 48 60 CONTENTS: Part 1 - Planning The Installation Part 2 - Electrical Connection Part
More informationMODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM
TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com MODEL HS115-3, HS115-4 & HS115-5 WIRING
More informationUser s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS
www.windsterhood.com User s Manual UNDER CABINET SERIES WS-208LF30SS WS-208LF36SS NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS
More informationREAD AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN
READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE
More informationE-Chef Hot Food Table Installation and Operation Manual
E-Chef Hot Food Table Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately.
More informationINSTALLATION INSTRUCTIONS & USE & CARE GUIDE 01A/02A Series Models 01A/02A Series Models RANGE HOOD LOCATION 1. The range hood must be installed just above the cooktop. 2. The minimum distance from the
More informationUser s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...
- TABLE OF CONTENTS Table of Contents 1 www.windsterhood.com Safety Information... 2 3 ISLAND SERIES User s Manual RA-7630SS RA-7636SS RA-7642SS RA-7648SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING.
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationOperation Manual and Parts Directory
Operation Manual and Parts Directory Lettuce Crisper LC Glastender, Inc. 5400 North Michigan Road Saginaw, MI 48604-9780 800.748.0423 989.752.4275 Fax 800.838.0888 / 989.752.4444 www.glastender.com Rev.
More informationModels: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call
Service Manual Design Basics Hot Food Tables Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF For Service Information, Call 800-544-3057 Please provide the following information: - Model number - Serial
More informationUser s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.
www.windsterhood.com User s Manual UNDER CABINET SERIES RA-3030SS RA-3036SS NOTE: This unit was designed for indoor residential use and DUCTED operation only. DO NOT USE OVER A WOOD GRILL OR MOUNT OUTDOOR
More informationUser s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.
TABLE OF CONTENTS 1 Table of Contents www.windsterhood.com Safety Information... 2 3 WALL MOUNT SERIES User s Manual RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS NOTE: PLEASE
More informationINSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationInstallation Instructions Remote Blowers
Installation Instructions Remote Blowers Models: REMP3, REMP16 Suitable for use in a household cooking area. Suitable for use with solid state controls. To complete this blower, a Dacor hood assembly or
More informationVENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016
VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016 HOODMART 172 REASER COURT ELYRIA, OH 44035 PHONE: (800)-715-1014 FAX: (800)-716-1214 1 THIS PAGE LEFT BLANK INTERNTIONALLY 2 LIMITED
More informationUser s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.
WALL MOUNT SERIES www.windsterhood.com User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed
More informationEnviro KES INSTALLATON MANUAL
Enviro KES INSTALLATON MANUAL Spring Air Systems Inc., Oakville, Ontario Phone (905) 338-2999, Fax (905) 338-0179, info@springairsystems.com www.springairsystems.com KES Installation Manual. This publication
More informationM Series Fan Filter Units
M Series Fan Filter Units Product Specifications... 2 Safety Instructions... 3 Receiving and Unpacking... 3 Pre-Installation Instructions... 3-4 Installation Instructions... 4 Electrical Installation Instructions...
More informationINSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the
INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the cooktop. 2. The minimum distance from the cooking surface
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationOperating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A
Operating Instructions & Parts Manual EN Silent Low-Profile Ceiling Fans Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A 465933 PLEASE READ AND SAVE THESE INSTRUCTIONS. READ CAREFULLY BEFORE
More informationWS-5530SS WS-5536SS WS-5542SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.
www.windsterhoocom UNDER CABINET SERIES User s Manual WS-5530SS WS-5536SS WS-5542SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit
More informationUser s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.
www.windsterhood.com User s Manual UNDER CABINET SERIES WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed
More informationDBF 4XL Dryer Booster Fans
Installation and Operation Manual Item #: 401315 Rev Date: 050814 DBF 4XL Dryer Booster Fans DBF4XL Kit Includes: Dryer Booster Fan, 1 pc Fan Mounting Bracket and Hardware, 1 pc Wall Label (Mount on wasll
More informationPLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCES. This equipment is design engineered for commercial use only
OWNER S MANUAL INSTALLATION OPERATION MAINTENANCE FRYER SRF-40/50 All equipment manufactured by SIERRA CORP. is for use with the type of gas specified on the rating plate and for installation will be in
More informationINSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200
INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200 Installer: Owner: READ AND SAVE THESE INSTRUCTIONS Please leave Installation Instructions with the range hood. Please keep Installation
More informationIVI WARNINGS: Must be followed carefully to avoid personal injury. [VL
INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Bull Outdoor Products BBQ Hood 1250 CFM Item# 66009 CONTENTS: Part 1 - Planning The Installation Part 2 - Electrical Connection Part 3 - Direction of Vent and
More informationUser s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS
www.windsterhood.com User s Manual UNDER CABINET SERIES WALL MOUNT SERIES WS-3230SS WS-3236SS WS-3242SS WS-3248SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY
More informationTable of Contents. Safety Information Content Checklist Measurements Preparation Installation
TABLE OF CONTENTS 1 Table of Contents Safety Information... 2 3 Content Checklist... 4 Measurements... 5 Preparation... 6 Installation... 7 8 Installation Diagram... 9 Operation & Features... 10 Cleaning
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationOPERATION MANUAL COUNTERTOP ELECTRIC CHAR BROILERS. for. Models: B-40 B-44 B-50. includes: INSTALLATION, USE and CARE
WELLS BLOOMFIELD, LLC 2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439 telephone: 775-689-5703 fax: 775-689-5976 www.wellsbloomfield.com 161 Model B-40 OPERATION MANUAL for COUNTERTOP ELECTRIC CHAR BROILERS
More informationHigh Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)
High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust
More informationOPERATIONS MANUAL DALPH1002, DALPH1503 PELLET HEATERS PALPH1002, PALPH1503 PLATE HEATERS. Alliance Products, LLC Murfreesboro, TN
Alliance Products, LLC Murfreesboro, TN 37129 1-800-522-3973 OPERATIONS MANUAL DALPH1002, DALPH1503 PELLET HEATERS PALPH1002, PALPH1503 PLATE HEATERS Rev. 1-28 2 GENERAL INFORMATION. 3 RECEIVING INSPECTIONS.
More informationSelf-Cleaning Range Hoods
Self-Cleaning Range Hoods Wall Mount and Island Range Hoods Installation and Operation Instructions Please read all instructions before installing and operating. All wiring and installation must be in
More informationUser s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )
www.windsterhood.com User s Manual LINER SERIES WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 ) NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON
More informationREFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual
REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual For service information call 800-544-3057 Please have the following information available before calling. Information can be found on
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationOperator s Manual. Cookshack, Inc. Model FEC500 Fast Eddy s Oven. Version 06.2 Serial No:
Cookshack, Inc. Operator s Manual Model FEC500 Fast Eddy s Oven Version 06.2 Serial No: Fast Eddy s Model FEC500 1 Ver. 06.2 Dear Cookshack Customer: Your Model FEC500 FAST EDDY S BARBEQUE OVEN by Cookshack
More informationOperation & Maintenance Manual MONSOON WET DOWNDRAFT TABLE. Visit our Website for more information on this product.
DIVERSITECH Operation & Maintenance Manual MONSOON WET DOWNDRAFT TABLE MDD-MINI MDD-3X4 MDD-3X6 MDD-3X8 Visit our Website for more information on this product www.diversitech.ca 2500 Alphonse Gariepy,
More informationINSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind Professional Series Liners
INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind Professional Series Liners Professional Series Models Model Width CFM Type of Motor & Blower PSL736 34-3/8 * Remote PSL742 40-3/8 * Remote PSL748
More informationFried Food Warmers Series. Series: FW Operation Manual
Fried Food Warmers Series Series: FW Operation Manual BKI LIMITED WARRANTY 2812 Grandview Dr. Simpsonville, SC 29680 USA (864) 963-3471 Toll Free: (800) 927-6887 Fax: (864) 963-5316 WHAT IS COVERED WHO
More informationREAD AND SAVE THESE INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you
More informationSP-Series Ovens. New Extended Warranty on the SP-Series oven models: OWNERS MANUAL (SP-750 & SP-1000) SP-750
SP-Series Ovens (SP-750 & SP-1000) OWNERS MANUAL SP-750 shown with optional legs New Extended Warranty on the SP-Series oven models: 1 Year on Labor on warranty parts 1 Year on switches, relays, belts,
More informationUser s Manual WS-5830SS WS-5836SS WS-5842SS
www.windsterhoocom UNDER CABINET SERIES User s Manual WS-5830SS WS-5836SS WS-5842SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit
More informationPLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.
File name: ARFG-42FB Care & Use Manual.pub Last revised: June 3rd 2008 PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. ASSEMBLER / INSTALLER
More informationREAD AND SAVE THESE INSTRUCTIONS. Air Boss Model T5200 Custom Packaged Electronic Air Cleaner. TRION
READ AND SAVE THESE INSTRUCTIONS Air Boss Model T5200 Custom Packaged Electronic Air Cleaner TRION Installation, Operation, & Service Manual Electrostatic Precipitators for Commercial & Industrial Applications
More informationCELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler
CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and
More informationOperation Manual and Parts Directory
Operation Manual and Parts Directory ST24, ST36, ST48, ST60, ST72 and ST96 Slide Top Coolers ST36-B ST48-SF Glastender, Inc. 5400 North Michigan Road Saginaw, MI 48604-9780 800.748.0423 989.752.4275 Fax
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL TUBE AXIAL FANS BTA, WTA, HTA, DDA The purpose of this manual is to aid in the proper installation and operation of the fans. These instructions are intended
More informationELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. U.S.A. WARNING FOR YOUR
More informationWax Base Heater & Dispenser
Wax Base Heater & Dispenser Service Manual Models: IDWB2/0900, IDWB2/0775, IDWB3/0900, IDWB3/0775, IDWB4/0900, IDWB4/0775 Introduction............................................................................
More informationMODEL DH-65 (2009 and Newer)
MODEL DH-65 (2009 and Newer) INSTRUCTION MANUAL 472 South Mill Street Alamo, TN 38001 PHONE: 800-851-8180 FAX: 731-696-3180 www.southern-pride.com sales@sopride.com service@sopride.com SERVICE: 800-437-2679
More informationMODEL SC-200-SM ( )
MODEL SC-200-SM (2007-2009) OWNERS / OPERATIONS MANUAL 472 South Mill Street, Alamo TN 38001 SALES: 800-851-8180 FAX: 618-993-5960 www.southern-pride.com sales@sopride.com service@sopride.com SERVICE:
More informatione Bath Fan with Light User s Guide
e Bath Fan with Light User s Guide abfl50uq, BFL60UQ, BFL70, BFL85 Item Stock Number(s): BFL50UQ, BFL60UQ, BFL70, BFL85 IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY
More informatione Bath Fan with Light User s Guide
e Bath Fan with Light User s Guide abfl100rnl, BFL125RNL Item Stock Number(s): BFL100RNL, BFL125RNL IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING
More informationOwner s Guide Installation & Operation
Owner s Guide Installation & Operation Hot Top HHT Series Hestan Commercial Corporation 3375 E. La Palma Ave Anaheim, CA 92806 (888) 905-7463 RETAIN THIS MANUAL FOR FUTURE REFERENCE P/N 002130 REV 1 IMPORTANT
More informationModular Supply Make-Up Air Unit
Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features
More informationIMPORTANT INSTRUCTIONS - OPERATING MANUAL
IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: AK80LSL, AK100LSL Exhaust Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
More informationTRI-STAR INC SOUTH STANDARD AVENUE, SANTA ANA, CA Ph: Fax: MODEL #. OWNER S MANUAL
TRI-STAR INC 2205 SOUTH STANDARD AVENUE, SANTA ANA, CA 92707 Ph: 714 424 9380 Fax: 714 424 9385 MODEL #. OWNER S MANUAL INSTALLATION OPERATION MAINTENANCE All equipments manufactured by Tri-star Inc. for
More informationA. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:
SECTION 15860 - FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL
More informationCART & TROUGH ASSEMBLY for BRAISING PAN UNITS
OPERATOR MANUAL IMPORTANT INFORMATION, KEEP FOR OPERATOR This manual provides information for: CART & TROUGH ASSEMBLY for BRAISING PAN UNITS Stainless Steel THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
More informationDESIGN CLASS FUNCTION
PROFESSIONAL QUALITY COOKING EQUIPMENT INSTALLATION MANUAL FOR MEDALLION DUAL FUEL RANGES MODEL NUMBERS: ARR-304DF, ARR-366DF, ARR-364GDDF, ARR-364GRDF, ARR-486GDDF, ARR-486GRDF, ARR-4822GDDF, ARR-484X2GRDF,
More informationInstallation, Operation and Maintenance Manual
Document 483502 Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the
More informationMODEL SC-600-SM OWNERS / OPERATIONS MANUAL
MODEL SC-600-SM OWNERS / OPERATIONS MANUAL 5003 Meadowland Pky. - MARION, ILLINOIS 62959 PHONE: 618-997-9348 FAX: 618-993-5960 SALES: 800-851-8180 www.southern-pride.com sales@sopride.com service@sopride.com
More informationPLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.
File name: ARDI Care & Use Manual.pub Last revised: Oct 10th 2008 PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. ASSEMBLER / INSTALLER Leave
More informationInsulated Ventilators. Operating Instructions & Parts Manual
Operating Instructions & Parts Manual EN Insulated Ventilators Models 3DPE4B, 3DPE5B, 3DPE6A, 5AE70B, 5AE71B, 5AE72A, 5AE73 thru 5AE81, 6WZN1, 6WZN2, 36WG64 and 36WG65 465932 PLEASE READ AND SAVE THESE
More informationM-11 Series. Installation and Service Manual
M-11 Series Installation and Service Manual INTRODUCTION SPECIFICATIONS UNPACKING MOUNTING ELECTRICAL OPERATION MAINTENANCE REPLACEMENT PARTS TROUBLESHOOTING ***IMPORTANT*** THIS MANUAL CONTAINS PRECAUTIONARY
More informationBathroom Exhaust Fan
Bathroom Exhaust Fan Models: Installation and Operation Instructions Please read all instructions before installing and operating. All wiring and installation must be in accordance with CEC, NEC and local
More informationPOLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL
POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL www.polartemp.com TABLE OF CONTENT Disclaimer.......................................... Page 3 Inspection, unpacking and FMU setup.................. Page
More informationIndirect Gas-Fired Make-Up Air
Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up
More informationUSER MANUAL Stock Pot Range
Stock Pot Range MODEL: 351CPGSPR18(L/N) 11/2017 This user s manual contains information and guidelines collected from years of industry experience. For optimal safety and efficient operation, please make
More informationService Parts, Kits and Accessories
The parts identification guides on the following pages have been designed to give a quick reference to component parts used on pilot ignition agricultural building heaters. The guides identify components
More informationENERVEX RSV CHIMNEY FAN
ENERVEX RSV 200-450 CHIMNEY FAN 3000775 06.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F: 770.587.4731
More informationInstallation & Maintenance Instructions
Installation & Maintenance Instructions Listed & Tested to UL641, ULC-S609, ULC/ORD C441 AMERIVENT Model PVP Pellet Pipe Plus Vent Connector for Pellet-Fuel Appliances and Other Low-Temperature Applications
More informationStandard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual
Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check
More informationINSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS
INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS Fan Models: CX1401, CX1801 Read all warnings and instructions before beginning to install this fan. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
More informationUNDERCOUNTER DISHWASHER
OWNER S MANUAL BLAKESLEE Division of Blako Inc. UNDERCOUNTER DISHWASHER UC-21 I.R.S. INTEGRATED RECIRCULATING SYSTEM DESIGN 1844 South Laramie Avenue Chicago, IL 60804 Phone (708) 656-0660 Fax (708) 656-0017
More informationRPI Industries, Inc.
IMPORTANT: THE FOLLOWING INFORMATION SHOULD BE RETAINED FOR FUTURE REFERENCE RPI Industries, Inc. building a better case for sales BAKERY and DELI USE AND SERVICE MANUAL WARRANTY INFORMATION SPECIFICATIONS
More informationStandard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual
Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check
More informationXLR SERIES INSTRUCTION MANUAL XLR-600 & XLR-1400 XLR-600 XLR-1400
XLR SERIES XLR-600 & XLR-1400 INSTRUCTION MANUAL XLR-600 XLR-1400 Distributing, L.L.C. 472 South Mill Street, Alamo, TN 38001 Sales: 800-851-8180 www.southernpride.com - sales@sopride.com - service@sopride.com
More informationUSER S OPERATING AND INSTRUCTION MANUAL
Grand Rapids, Michigan, U.S.A. 49504-5298 USER S OPERATING AND INSTRUCTION MANUAL MODEL 1508-NLG SELF-ACTUATING TRAY LIDDER 1508S20000CV2 INDEX SAFETY INSTRUCTIONS... 1508S20002 SET UP... 1508S20003 OPERATING
More informatione Heater/Exhaust Fan/Light User s Guide
e Heater/Exhaust Fan/Light User s Guide abflh70l, BFLH85L Item Stock Number(s): BFLH70L, BFLH85L IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING
More informationXLR SERIES INSTRUCTION MANUAL XLR-600-SL, XLR-1000-SL, XLR-1400-SL, XLR
XLR SERIES XLR-600-SL, XLR-1000-SL, XLR-1400-SL, XLR-1600-4 Wood Burning BBQ Pits & Smokers INSTRUCTION MANUAL Distributing, L.L.C. 5003 Meadowland Parkway - Marion, Illinois 62959-5892 PHONE: 618-997-9348
More informatione Bath Fan with Light User s Guide
e Bath Fan with Light User s Guide abfl125rok Item Stock Number(s): BFL125ROK IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL,
More informationViking Use & Care Manual
Viking Use & Care Manual Viking Range Corporation Front Street Greenwood, Mississippi 890 USA (66) 455-00 For product information call -888-VIKING (845-464), or visit the Viking Web site at vikingrange.com
More informationCRISP N HOLD FRIED FOOD HOLDING CABINET MODELS: CNH14, CNH18, CNH28, CNH40 OWNERS / OPERATORS MANUAL
CRISP N HOLD FRIED FOOD HOLDING CABINET MODELS: CNH14, CNH18, CNH28, CNH40 OWNERS / OPERATORS MANUAL MANUFACTURED BY: CARTER-HOFFMANN 1551 McCORMICK AVENUE MUNDELEIN, IL 60060 U.S.A. PHONE: 847-362-5500
More informationuser manual Model #: BLZ-WVH-42
user manual Model #: BLZ-WVH-42 ii Table of Contents Table of Contents 1 Safety Notice III-V 2 Diagrams 1-3 Hood Dimensions............ 1 Control Panel.............. 2 Clearance............... 3 3 Installation
More information12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING
12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING This manual contains very important safety warnings and information. Read and save these instructions for future
More informationENERVEX GSV GREASE FAN
ENERVEX GSV 200-450 GREASE FAN 3001391 12.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F: 770.587.4731
More informationUser s Manual WS-68N30SS WS-68N36SS WS-68N42SS
ISLAND SERIES www.windsterhood.com User s Manual WS-68N30SS WS-68N36SS WS-68N42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit
More informationImperial Cal Products, Inc.
Imperial Cal Products, Inc. Read Before Starting Installation! Inspect your range hood prior to installing! Any cosmetic defects must be reported to us prior to installation. Once this hood is installed,
More informationuser manual Model #: BLZ-HOOD
user manual Model #: BLZ-HOOD ii Table of Contents Table of Contents 1 Saftey Notice III-V 2 Diagrams 1-3 Hood Dimensions............ 1 Control Panel.............. 2 Clearance............... 3 3 Installation
More information