Call for Pricing PLACE YOUR ORDER TODAY! cwip.com

Size: px
Start display at page:

Download "Call for Pricing PLACE YOUR ORDER TODAY! cwip.com"

Transcription

1 HVAC 2015 Like us on Facebook Call for Pricing PLACE YOUR ORDER TODAY! cwip.com

2 HVAC MAINTENANCE CHECKLIST Maintain equipment to prevent future problems and unwanted costs. Keep cooling and heating systems at peak performance by performing pre-season check-ups. It's best to check the cooling system in the spring and the heating system in the fall. To remember, you might plan the check-ups around the time changes in the spring and fall. A Typical Maintenance Check-up Should Include the Following: Check thermostat settings to ensure the cooling and heating system keeps you comfortable when you are home and saves energy while you are away. Tighten all electrical connections and measure voltage and current on motors. Faulty electrical connections can cause unsafe operation of your system and reduce the life of major components. Lubricate all moving parts. Parts that lack lubrication cause friction in motors and increases the amount of electricity you use. Check and inspect the condensate drain in your air conditioner, furnace and/or heat pump (when in cooling mode). A plugged drain can cause water damage in the unit and affect indoor humidity levels. Check controls of the system to ensure proper and safe operation. Check the starting cycle of the equipment to assure the system starts, operates and shuts off properly. Cooling Specific Clean evaporator and condenser air conditioning coils. Dirty coils reduce the system's ability to cool the unit and cause the system to run longer, increasing energy costs and reducing the life of the equipment. Check your air conditioner's refrigerant level and adjust if necessary. Too much or too little refrigerant will make your system less efficient increasing energy costs and reducing the life of the equipment. Clean and adjust blower components to provide proper system airflow for greater comfort levels. Airflow problems can reduce your system's efficiency by up to 15 percent. Heating Specific Check all gas (or oil) connections, gas pressure, burner combustion and heat exchanger. Improperly operating gas (or oil) connections are a fire hazard and can contribute to health problems. A dirty burner or cracked heat exchanger causes improper burner operation. Either can cause the equipment to operate less safely and efficiently. Monthly Inspect, clean or change air filters once a month in your central air conditioner, furnace and/or heat pump. A dirty filter can increase energy costs and damage your equipment, leading to early failure. Source: Energy Star 2

3 CONDENSING UNITS & HEAT PUMPS 13 SEER Dry R-22 Split System Condensing Units & Heat Pumps Energy-efficient compressor Copper tube/aluminum fin coil Nitrogen charged Factory-installed in-line filter Easy access service valve Gray color paint to resist corrosion NOT for new installations, use as replacement for existing system Five-year compressor warranty and one-year parts (limited warranties) available only through the manufacturer). Tons Condensing Units Nominal (BTU) Cooling/ Heating MFG Volts W x D x H Replacement Parts Compressor Motor Fan Blade ,000 GSC /230 26" x 26" x 29¾" ,000 GSC /230 26" x 26" x 27½" ,000 GSC /230 26" x 26" x 30¼" ,000 GSC /230 29" x 29" x 30¼" Heat Pump Units ,000/16,800 GSH /230 26" x 26" x 32¼" ,000/22,000 GSH /230 26" x 26" x 32¼" ,000/26,800 GSH /230 29" x 29" x 34¾" ,000/32,000 GSH /230 29" x 29" x 38¼" SEER R-410A Split System Condensing Units & Heat Pumps Energy-efficient compressor Brass liquid and suction service valves with sweat connections Copper tube/aluminum fin coil 1/6 HP condenser fan motor R-410A chlorine-free refrigerant Contactor with lug connections Factory-installed liquid line filter drier Five-year compressor warranty and one-year parts (limited warranties) available only through the manufacturer). Tons Condensing Units Nominal (BTU) Cooling/ Heating MFG Volts W x D x H Replacement Parts Compressor Motor Fan Blade ,000 VSX /230 27½" x 26" x 26" ,000 VSX /230 26" x 26" x 27½" ,000 VSX /230 26" x 26" x 27½" ,000 VSX /230 29" x 29" x 28¾" Heat Pump Units ,000 VSZ /230 26" x 26" x 32¼" ,000 VSZ /230 26" x 26" x 32¼" ,000 VSZ /230 26" x 26" x 32¼" ,000 VSZ /230 29" x 29" x 32¼"

4 AIR HANDLERS AR Series Multi-Position Air Handlers Direct-drive, multi-speed motor Transformer and blower time-delay Check flowrater expansion device for cooling-only and heat pump applications Rust-resistant, fully insulated steel cabinet with galvanized, stucco-embossed finish Built-in coil has horizontal, vertical and downflow drain pans with secondary drain connections Suitable for use with R-22 or R-410A Power supply entry at top with low-voltage entry on left side and top Tons Cooling (BTU) MFG 0.3" ESP High/Med/Low W x D x H Service Valve Liquid Suction ,000-24,000 ARUF /790/570 15½" x 22" x 42¹ 8" 3/8" 3/4" ,000 ARUF /1230/980 19½" x 22" x 46¾" 3/8" 3/4" ,000-42,000 ARUF /1400/ " x 24" x 53¼" 3/8" 7/8" AW Series 10 SEER Wall Mount Air Handlers Vertical stud-mount or wall-mount Direct drive, multi-speed motor High efficiency evaporator coil Filter rack with filter included Suitable for use with R-22 or R-410A 20 3/16"W x 16¹ 8"D x 36"H Tons Cooling BTUH MFG Service Valve Liquid Suction ,000 AWUF /8" 5/8" ,000 AWUF /8" 5/8" HKR Slide-in Electric Heat Kits HKS Slide-in Electric Heat Kits MFG KW Circuit Breaker Single Phase BTU HKR-05A 5 No 16, HKR-08C 8 Yes 23, HKR-08A 8 No 23, HKR-10CA 10 Yes 32, HKR-10A 10 No 32,400 MFG KW Circuit Breaker Single Phase HKS-08XC 8 Yes HKSX-08XC 8 No HKSX-10XC 10 No HKSC10-C 10 Yes HKSX05XC 10 No 4

5 HVAC EQUIPMENT Cased Upflow/Downflow Indoor Coils For use with split-system air conditioners, heat pumps and gas furnaces Suitable for both R-410A and R-22 refrigerants Rust-resistant, high-temperature thermoplastic drain pans With check flowrater expansion device Rifled aluminum tubing and wave pattern aluminum fin coils Foil-face insulation and split-seam front cabinet for easy access Nom. Tons MFG Dimensions Connections W x D x H Plenum Opening Width Liquid Suction CAPF1824A6A 14" x 21" x 18" 13" 3/8" 3/4" CAPF1824B6 17½" x 21" x 18" " 3/8" 3/4" CAPF3030A6 14" x 21" x 22" 13" 3/8" 3/4" CAPF3030B6 17½" x 21" x 22" " 3/8" 3/4" CAPF3636A6 14" x 21" x 22" 13" 3/8" 7/8" CAPF3636B6 17½" x 21" x 22" " 3/8" 7/8" WHEREVER YOU ARE... WE ARE! R From humble beginnings in Hyattsville, Maryland in 1981, to our modern state-of-the-art facilities, Central Wholesalers, Inc. has grown one customer at a time. Whether you are a walk-in customer to our parts counter or the member of a multifamily management team, our goal has been, and continues to be, excellence in service coupled with competitive pricing. R R R R Our success is a direct result of listening to our customers and responding to their needs. We are not just a catalog company. While we provide our catalog as a convenience, we want to get to know you and the needs of your company on a one-to-one basis. Give us the opportunity to maximize your profitability, organize your maintenance shops and provide employee training. R R R FREE NEXT DAY DELIVERY No minimum order! 5

6 REFRIGERANT & HVAC ACCESSORIES HCFC R-22 Refrigerant For high/medium temperature refrigeration and air conditioning Color code: light green Lubricant: mineral, alkylbenzene, polyolester Copy of CFC certificate must be on file to purchase 30 lb. canister EACH R-410A Refrigerant Long term HFC refrigerant to replace R-22 Copy of CFC certificate must be on file to purchase 25 lb. canister EACH R-421A Refrigerant A non-ozone depleting alternative for R-22 for use in air conditioning as well as medium and high temperature residential, commercial and industrial refrigeration applications 25 lb. cylinder EACH Plastic Air Conditioner Condensing Unit Pad 30" x 30" x 2" EACH SPP7S SPP-5 SPP-6 Super-Booster Relays SPP For all residential and commercial PSC A/C units and heat pumps Can be used on VAC units For low voltage and hard starting compressors MFG BTUs Increased Torque U/M K-120K 300% Each K-120K 500% Each S 18K-120K 600% Each Air Conditioner Disconnect 60A switch rated for 10HP motors at 240VAC On/off circuit breaker type switch Four 1" knockouts: two rear and two bottom end wall 6½"H x 47 8"W x 2¾"D EACH Air Conditioner Pull Out Units For use with residential and commercial air conditioner and heat pump disconnects Fused pullout devices UL listed Liquid Tight Whip Assembly For installation with air conditioners, swimming pools, hot tubs, outdoor lighting, heat pumps and compressors Includes straight non-metallic connector, 90 non-metallic connector, liquid-tight non-metallic conduit, #8 or #10 wires #10 wire gauge 6' length UV resistant UL & CSA certified H x W x D Amps Wire Range HP Max U/M ½" x 5" x 25 8" 30A #8 - #14 3 Each " x 5¹ 8" x 2¾" 60A #2 - #12 10 Each Conduit Size U/M /2" Each /4" Each 6

7 HVAC ACCESSORIES Air Conditioner Treatment Tablets Prevents water overflow and damage from air conditioner and air handler drain pans One pouch needed for two square feet of drain pan area PACK OF 6 Air Conditioner Drain Pan Treatment Tablets Controls odor and growth of slime through bacteriostatic action Prevents water overflow and damage from blocked air conditioner drain pans TABLETS Air Conditioner & Refrigeration Anti-Clog Unit Controls slime build-up, drain pan overflows, harmful bacteria growth and musty odors from bacterial slime accumulations For use in drain pans of air conditioner and refrigeration systems BOX OF 24 Pan Patch Epoxy Pan Sealant Two part epoxy creates permanent bond Stops leaks or holes in drain pans Works through standing water Self-leveling formula Adheres to almost any surface, including metal, wood and concrete PACK OF 10 MADE IN USA 1/2 HP Oil-Less Refrigerant Recovery System Fast recovery of Class II, III, IV and V refrigerants including R-410A Single valve control CPR valve regulates refrigerant to the compressor LED signals Safety overfill shut-off Color-coded hook-ups 115VAC rating 13.9" x 12.4" x 12.5" EACH Recovery Cylinder Y valve for liquid/vapor 400 PSI rating and 3/4" plug for a float switch 50 lbs EACH Compute-A-Charge High-Capacity Charging Scale Fully-enclosed, removable metal scale platform Battery operated LCD readout displays either imperial or metric measurements Hand-held remote has a 6' coil cord, hanging hook and backed with magnet Two 9V batteries included Operates 60 continuous hours EACH 7 CFM Yellow Jacket Bullet Vacuum Pump Two-stage rotary vane; 1/2 HP motor Intake fitting: 1/4" x 3/8" x 3/8" 25 micron factory micro rating Oil capacity: 28 oz. 6' power cord 115V, 60 Hz. 6"W x 11½"H x 16¼"L EACH Vacuum Pump Oil Frees air conditioner or refrigeration applications from air and moisture before recharging the system Gallon EACH 7

8 HVAC ACCESSORIES Refrigerant Leak Detector Uses micro-computer circuitry and a halogen sensor to accurately detect HFC-134a, CFC-12, R410A and other halogenated refrigerants and vapors Ten settings and audible alarm EACH Digital LCD Vacuum Gauge Thermal conductivity sensor automatically compensates for temperature with no calibration Tough ABS housing and solid state circuitry for accuracy Includes gauge with 9V battery and hook EACH MFG RLD10 Refrigeration Service Manifolds & Hose Two-valve brass manifold Swivel hanger Color coded hoses 3¹ 8" gauges with R-Y-B 60" hoses Use with R-22, R-404A or R-410A EACH PLUS II with SealRight Charging Hoses For R-22, R-134A or R-507 Gaskets resist deterioration from existing CFC, HCFC and HFC refrigerants and oils 45 fitting traps refrigerant in hose when disconnected 60" length Red, yellow and blue PACK PLUS II with Ball Valve Charging Hoses For R-410A Uses standard gasket and valve opener Full flow valve 1/4" female flare fittings 4,000 PSI burst pressure 60" length Red, yellow and blue PACK Charging Manifold and System Analyzer For both R-22 and R-410, up to 100 different refrigerants Built in pressure/temperature chart for all refrigerants Digital read out Data logging to USB port 300 swivel hook Two year warranty EACH 8

9 HVAC ACCESSORIES Pro-Flush HVAC Flushing Kit Flushing solvent for air conditioning and refrigeration systems Formulated for R-410A retrofits, refrigerant conversions and compressor burnouts Compatible with CFC and HFC refrigerants and compressor oils Non-VOC and conforms to EPA SNAP standards Includes charging hose, injector trigger nozzle, reusable tank with pressure relief valve, 16 oz. bottle of Pro-Flush KIT 16 oz. Pro-Flush EACH Gallo Drain Gun & Swoosh Cartridges Lightweight, portable tool designed to blow out condensate drain lines instantly CO2 cartridges send 800 PSI of oil free food grade air through drain lines Tapered fitting for 3/8" to 3/4" drain openings Flexible hose assembly Safe for environment and recyclable Name U/M Gallo Gun Each Swoosh Cartridges 12 Pack Super Seal Advanced Sealant Permanently seals and prevents leaks in refrigeration systems Works while in the line with no down time Contains DRYR to eliminate moisture For systems 1½ to 5 tons 3 oz. can EACH Kwik-Charge Kwik-Charge accepts liquid refrigerant from the cylinder and discharges into low side of the system 1/4" female SAE flare inlet 1/4" male SAE flare outlet Works with R-410A EACH Condensate Pump ABS plastic for high impact and corrosion resistance Three-quart plastic reservoir Includes 20' of 3/8" tubing 3,000 RPM motor 120V, 1.9A Inlet 1³ 8" ID; outlet 1/4" NPT 9¼"W x 5½"D x 8½"H 22' of lift EACH HVAC Non-Acid Line Cleaner Clears air conditioner lines and drains Goes right through clogged drains to the source of the blockage Safe to use in garbage disposals and metal or plastic pipes Quart CASE OF 12 Coil Cleaner and Brightener Non-toxic Easy to apply, non-acid coil cleaner and brightener Quickly removes dirt and grim from outdoor coils and leaves them clean and bright Strong foaming action removes even stubborn deposits easily Gallon EACH Size U/M oz. Each Gallon Each Triple D Coil Cleaner For use on condenser and evaporator coils Metal safe and does not attack aluminum or copper coil components Extends equipment life and diminishes potential for refrigerant leaks Biodegradable Biodegradeable Evap Foam No-Rinse Coil Cleaner Heavy-duty detergent formulated with special surfactants and alkaline cleaners Ideal for use on most coils, but particularly suited for use on cooling or evaporator coils Can be sprayed either right side up or upside down 18 oz EACH 9

10 HVAC ACCESSORIES Filter Driers Sealed drier removes moisture, scale, sludge, dirt, acid, carbon and solder particles Connection Type U/M /8" Solder Liquid Line Each /8" Solder Reversing Each /8" Sweat Reversing Each Air Conditioner & Heat Pump Compressors: A/B Series Single phase 60 Hz. R /208 volts Tons MFG BTUH Suction Tube ID Discharge U/M H2EB18SABCA 18,300 5/8" 3/8" Each H2EB223ABCA 22,600 5/8" 3/8" Each H2EB24SABCB 24,200 3/4" 1/2" Each Other sizes and manufacturers available, please contact your sales representative. Core Removal Tool Removes a valve core from a 1/4" male flare access fitting without loss of refrigerant Ball valve design allows tool to close with quarter turn EACH Valve Core Tool 1/4" access valves with a hollow handle for storage Includes 1/4" bit with six extra 1/4" valve cores EACH Access Valve Caps To seal access valves and other 1/4" male SAE connections 1/4" tubular seal gasket EACH Metal Fin Tool Straightens condenser and evaporator fins quickly and easily Cleans away lint, rust, dirt and other debris particles Adjustable tension EACH Swaging Tool Kit For soft metal tubing 45 flares and swags with screw-type feed in complete kit with plastic box Flares: 1/8", 3/16", 1/4", 5/16", 3/8", 7/16", 1/2", 5/8" and 3/4" OD Swages: 3/16", 1/4", 5/16", 3/8", 1/2", 5/8" and 3/4" OD KIT Service Wrenches 1/4" and 3/16" end sizes 3/8" and 5/16" end sizes For accessing liquid and suction based valves Knuckle-Saver for use in tight spaces Type U/M Straight Each Offset Each 10

11 BLOWER MOTORS 3.3" Diameter General Purpose Blower Motors: Shaded Pole, Air-Over Totally enclosed, non-ventilated motor for use in kitchen exhaust fans and other air-over fan equipment operating in dirty, greasy and non-combustible atmospheres MFG HP Amps Volts Shaft Rotation RPM U/M Fasco D541 1/ /4" x 2¼" CCW 1500 Each Fasco D540 1/ /4" x 2¼" CW 1500 Each 5" Diameter Fan Coil Air Conditioning and Heating Unit Motors: Shaded Pole, Air-Over Interchangeable with most fan coil air conditioning or heating units MFG HP Amps Volts Shaft Rotation RPM U/M 1/10, 1/30, A.O. Smith 89 1/35, 1/60, /2" x 10½" Reversible 1,050: 1/70 5-Speed Each Fasco D289 1/10, 1/30, 1/40, 1/45, 1/ /2" x 10¾" Reversible 1,050: 5-Speed Each 5.625" Condenser Fan and Heat Pump PSC Motor Totally enclosed outdoor sleeve bearing for outdoor air conditioning units, heat pumps and refrigeration condensers MFG HP Amps Volts Shaft Rotation RPM U/M A.O. Smith FSE1026S 1/ /2" x 6" Reversible 1,075 Each 5.625" Diameter Direct-Drive Furnace Blower Motors: High Efficiency, Air-Over Designed and built primarily for furnace blowers Also used for air conditioners, unit heaters and other shaft-mounted fan and blower equipment MFG HP Amps Volts Shaft Rotation RPM U/M A.O. Smith DL1036 1/3, 1/4, 1/5 5.9, 4.6, /2" x 4" Reversible 1,075: 3-Speed Each A.O. Smith DL1026 1/ /2" x 4½" Reversible 1,075: 3-Speed Each 5" Diameter Fan Coil/Air Conditioning Blower Motor: PSC, Air-Over Interchangeable with most fan coil air conditioning or heating units MFG HP Amps Volts Shaft Rotation RPM U/M A.O. Smith /8, 1/10, 1/15, 1/ /2" x 10³ 8" Reversible 1,550: 4-Speed Each 11

12 RUN CAPACITORS & CONTROLS Oval Dual Run Capacitors 370V Capacity Run Start U/M MFD 5MFD Each MFD 5MFD Each MFD 5MFD Each Oval Run Capacitors 370V Capacity U/M MFD Each MFD Each MFD Each Oval Dual Run Capacitors 440V Capacity U/M Run Start MFD 5MFD Each Mounting Kit for Run Capacitors Includes metal bracket, rubber boot and mounting hardware EACH Round Dual Run Capacitors 370V Capacity Run Start U/M MFD 5MFD Each MFD 5MFD Each MFG MFG Digital Capacitor Tester Pocket size, battery operated: four AA not included Capacity value from.01 to 10,000MFD Checks run, start and DC electrolytic capacitors EACH One-Pole Definite Purpose Contactor Straight-through wiring Replaces 1½ pole devices used primarily in residential central air conditioners -40 F to 150 F Continuous duty cycle 30A, 24VAC EACH Two-Pole Definite Purpose Contactor -40 F to 150 F 3¼" x 2¾" x 2½" 24V coil for cooler operation and increased life Double break contacts ensure positive make and break Screw terminals and double 1/4" quick connects UL and CSA approved FL-30A, Res-40A, 180 lra@230v EACH 12

13 THERMOSTATS Heating/Cooling Light Duty Line Voltage Thermostat For direct control of fan coils, fans, motor starters, circulator motors, contactors and valves for heating, cooling or SPDT applications Two dial stops for setting a maximum (66 to 87 F) or minimum temperature (60 to 81 F) Mounts on 2" x 4" electrical box Includes set point locking feature at 66, 72, 78 or 81 F Vertical or horizontal mounting 120V Beige MFG Type H x W x D U/M A Thermostat 4½" x 2¾" x 1¾" Each S29-21 Subbase 5¹ 8" x 2¾" x 2¹ 8" Each MFG T834N Heat/1 Cool Stage Low Voltage Thermostat For use with 24V conventional systems or single stage heat pumps Fan (SPDT): on, auto Switching system: heat, off, cool 4.75"H x 2.88"W 45 to 95 F White EACH MFG 1F Heat/1 Cool Stage Non-Programmable Digital Thermostat 24 volts System switch: heat, off, cool, emergency auto, auto, on Hardwired with battery back-up For use with heat pumps or conventional systems 5.1"W x 3.7"H x 1.1"D 45 to 90 F White EACH MFG TB6575A1000 Suite PRO Fan Coil Non-Programmable Digital Thermostat Line voltage on/off control for fans, valves, compressors or auxiliary electric heaters in fan-coil and small air-conditioner applications Two or four pipe manual heat/cool changeover Three-speed fan Supply voltage: 120 or 240 VAC 50 F to 90 F 3³ 16"H x 5¹³ 16"W EACH MFG TH3110D1008 FocusPRO Non-Programmable Digital Thermostats Dual powered: battery or hardwire For use with heat pumps or conventional 24V systems or 750mV heating systems 40 to 99 F White MFG Stage W x H x D U/M TH5110D Heat/ 1 Cool TH5220D Heat/ 2 Cool 4½" x 37 16" x 15 16" 5¹³ 16" x 39 16" x 1½" Each Each Digital 1 Heat/1 Cool Stage Non-Programmable Digital Thermostat PRO 3000 Dual powered: battery or hardwire Electrical rating: 20 to 30 VAC Backlit display For use with conventional systems or heat pumps without auxiliary heat or 750mV heating systems 40 to 99 F 3¹³ 16"H x 5³ 8"W x 1¼"D EACH 13

14 AIR CONDITIONER UNITS Window Unit Air Conditioners Electronic controls with remote Slide out washable filter 8,000+ BTU units have 24-hour on/off timer with auto restart Nominal Cooling BTU EER Rating No 5, RG-51H Volts MFG W x D x H Controls Coverage 16¼" x 13¾" x Rotary 150 sq.ft Yes 8, RAD-81 19¹ 8" x 15¾" x 125 8" Remote 350 sq.ft Yes 10, RADS101 19¹¹ 16" x 20¹5 16" x 14¾" Remote 450 sq.ft. Compact Window Unit Air Conditioners Multi directional airflow Remote control units have 24-hour on/off timer Nominal Cooling BTU EER Rating Volts MFG W x D x H Controls Coverage No 5, FRA052XT7 16" x 13½" x 12" Rotary 150 sq.ft Yes 5, FRA054XT7 16" x 15½" x 12" Remote 165 sq.ft No 8, FRA082AT Yes 8, FRA086AT7 21³ 16" x 18¹ 8" x 14¹¹ 16" 18½" x 15½" x 13¼" Rotary Remote 350 sq.ft. 350 sq.ft Yes 10, FRA106CV1 19" x 215 8" x 14½" Remote 500 sq.ft. Thru-the-Wall Room Air Conditioner & Heat Unit Quick clean filtration R-410A refrigerant Four-way air direction Two fan/cool speeds Electronic controls with remote 9.5 EER rating 26"W x 21¹³ 16"D x 155 8"H Nominal Cooling BTU Nominal Heating BTU MFG Volts Coverage ,800 11,200 AJEQ12DCE 208/ sq.ft. 14

15 AIR CONDITIONER UNITS Thru-the-Wall Unit Air Conditioners Four-way air direction Electronic controls with remote 24-hour on/off timer, auto restart, auto, sleep and energy saver mode 24¹ 16"W x 20¼"D x 14½" Nominal Cooling BTU Heating BTU EER Rating Volts MFG Coverage , BG sq.ft , BG sq.ft * 10,000 10, /230 BGE sq.ft. * With electric heat Thru-the-Wall Unit Air Conditioners Four-way air direction Electronic controls Three fan/cool speeds Electronic controls with remote Nominal Cooling BTU Heating BTU EER Rating Volts MFG W x D x H Coverage Yes 8, FRA086HT1 24" x 19" x 14½" 350 sq.ft Yes 10, FRA106HT1 24" x 20½" x 14½" 500 sq.ft * No 10,000 10, FRA10EHT2 24" x 20½" x 14½" 500 sq.ft Yes 12, /230 FRA124HT2 24" x 20½" x 12½" 640 sq.ft 42417* No 12,000 10, /230 FRA12EHT2 24" x 20½" x 14½" 640 sq.ft. * With electric heat MFG FRA084KT7 MFG FRA103KT1 MFG PD-121B 350 sq.ft Casement Air Conditioner 8,000 BTU, 10.5 EER rating 115V Four-way air direction 14³ 16"W x 23"D x 20¼"H EACH 500 sq.ft Casement Air Conditioner 10,000 BTU, 9.5 EER rating 115V Remote control 14½"W x 23"D x 20¼"H EACH 550 sq.ft. Portable Room Air Conditioner Disposes its own condensate Electronic controls with remote R-410A refrigerant Window mounting kit Dual hose 24-hour on/off timer 12,000 BTU, 8.7 EER rating 19¹¹ 16"W x 18½"D x 337 8"H EACH 15

16 Refrigerant R-421A The easy choice Replaces R-22 in Multiple Applications Save Time and Save Money with a Quick and Easy Conversion to R-421A R-421A is a unique non-ozone depleting long-term replacement for R-22 R-421A is an environmentally green refrigerant R-421A can replace R-22 without unit modification and no change of oil R-421A does not contain a hydrocarbon, such as Butane R-421A can be used in compressors designed for R-22 R-421A can be used with mineral, AB or POE oils R-421A is the only two-component blend to replace R-22 R-421A is non-flammable and rated A1 by ASHRAE R-421A is comparable to R-22 in terms of performance across the R-22 temperature range R-421A can be topped off following repair of a system leak Choice R-421A is packaged with a proprietary lubricant EACH R-421A is a two-component blend packaged with a proprietary lubricant, which we recommend, be transferred from the cylinder in the liquid phase. In any operational leak scenario, the system may be topped off with R-421A without significant effect on performance. R-421A is an effective refrigerant for process cooling and air-conditioning. R-421A has demonstrated its effectiveness at higher temperatures, giving the added benefit of lower discharge temperatures. In many instances, lower compressor discharge temperatures have been reported, which can be a bonus where systems are running close to the recommended maximum. Charge the equipment with R-421A as a liquid. Do not charge liquid refrigerant directly into the compressor. The total charge of R-421A will depend on the type of system. For those with liquid receivers, it is the same as with R-22. For those without liquid receivers, it is recommended to add sufficient charge to achieve the required evaporator temperature while maintaining acceptable superheat. For optimum performance, it may be necessary to use a larger expansion valve orifice. Capillary systems do not need to be changed. NOTE: It is not unusual for the occasional bubble to be seen in the liquid line sight glass. A small number of bubbles in the sight glass is not a reliable indication of an under-charged system. E.P.A. regulations stipulate that the equipment converted is clearly labeled as containing R-421A. All prices are NET. No other discounts apply. Use promo code 1113 to receive flyer prices

Liquid Suction Suction Product # Mfg. # Tons Refrigerant Cool Btu Width Depth Height Line Line Valve Price

Liquid Suction Suction Product # Mfg. # Tons Refrigerant Cool Btu Width Depth Height Line Line Valve Price Items on this page NOTE: Contains a nitrogen holding charge which must be evacuated before charging with R-22. Condensing Units 2015 AC SPECIALS DRY R-22 13 SEER UNITS Nitrogen charged for use with R-22

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw

More information

The complete approach to the care and management of A/C & refrigeration systems

The complete approach to the care and management of A/C & refrigeration systems The complete approach to the care and management of A/C & refrigeration systems Testing oil with the Phase III Refrigeration Oil Acid Test Kit Flushing with OEM endorsed R x 11-flush Acid removal with

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

SHOWCASE. Spring Maintenance FREE PRODUCTS 2% OFF $1,500 WITH CASE QTY PURCHASE OF SELECT ITEMS SEE INSIDE COVER FOR DETAILS ANY ORDER OF OR MORE!

SHOWCASE. Spring Maintenance FREE PRODUCTS 2% OFF $1,500 WITH CASE QTY PURCHASE OF SELECT ITEMS SEE INSIDE COVER FOR DETAILS ANY ORDER OF OR MORE! Spring Maintenance SHOWCASE NO MINIMUM ORDER EFFECTIVE 3/15-5/31 2% OFF ANY ORDER OF $1,500 OR MORE! WITH CASE QTY PURCHASE FREE PRODUCTS OF SELECT ITEMS SEE INSIDE COVER FOR DETAILS MOTORS 2 CHEMICALS

More information

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Air Handlers Rheem Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check

More information

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES 1-year warranty on parts and labor. 5-year compressor warranty. If Registered a 10 year limited parts warranty applies. Designed for maximum

More information

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION AIR CONDITIONERS 2scu3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20644 May 204 Supersedes September 203 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 scu 3 lc 36 t - a Refrigerant

More information

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION CONDITIONERS DRY CHARGE UNITS PRODUCT SPECIFICATIONS Bulletin No. 20636 May 204 Supersedes March 202.5 to 5 Tons MODEL NUMBER IDENTIFICATION L C S 3 DC - 036-230 - 2 Lennox Minor Revision Number Air Conditioner

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

2 shp 13 lc 1 36 t - 1 a

2 shp 13 lc 1 36 t - 1 a HEAT PUMPs 2SHP3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20645 July 203 Supersedes June 202 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 shp 3 lc 36 t - a Refrigerant Type 2 =

More information

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) INDEX UNIVERSAL ELECTRONIC CONTACTOR UPGRADE SURESWITCH 79 Description Model(s) Page(s) SureSwitch... 49P11-843... 79 CONTACTORS 80 82 Description Model(s) Page(s) 1 Pole... 94-388 Thru 94-395... 80 2

More information

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS INTRODUCTION Please note that HUD Manufactured Home Construction and Safety Standard Section 3280.714, paragraph (a) and subparagraph

More information

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Air Handlers Ruud Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check

More information

AIR HANDLERS AIR HANDLERS

AIR HANDLERS AIR HANDLERS FORM NO. H11-33 REV. 1 Supersedes Form No. H11-33 AIR HANDLERS AIR HANDLERS RHBL- Efficiency X-13 (ECM) featuring Industry Standard R-410A Refrigerant RHAL- Standard Efficiency PSC featuring Industry Standard

More information

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER FORM NO. HFJ- Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER Features FH***TTS feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units. Versatile

More information

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGF SERIES 7-1/2 Ton C Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed

More information

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor Air Handlers Rheem Air Handlers RHML- Series X-13 (ECM) RHML feature GE s new X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 2 ton [7.0 kw] through 5 ton [17.6

More information

REFRIGERANT RECOVERY SYSTEMS

REFRIGERANT RECOVERY SYSTEMS REFRIGERANT RECOVERY 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com RECOVERY YELLOW JACKET HVAC&R HOSES YELLOW JACKET YJ-LTE Refrigerant

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2008 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR COILS 505,264M (65484504) 05/08 Supersedes 10/07 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PPH1SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER - 3, 4 and 5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE

More information

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11 SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual No.: 2100-479 Supersedes: NEW File: Volume

More information

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package

More information

WineZone Ceiling Mount Ductless Split 15

WineZone Ceiling Mount Ductless Split 15 WineZone Ceiling Mount Ductless Split 15 Requires an HVAC technician to install and charge with R-22 refrigerant. Easy to install. Unit plugs into wall outlet. Industrial grade unit for longer life. Indoor

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3 FORM NO. H66- REV. 1 Supersedes Form No. G66-6 Rev. WH1T SERIES Constant Torque (ECM) Efficiencies up to 1 SEER HIGH EFFICIENCY AIR HANDLER Features WH1T feature a Constant Torque motor (ECM) which provides

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH TXV Horizontal Slab Coils WLSH These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model Q4SD Series M120 Product Line Single Packaged Heat Pump 13 SEER 3-5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace

More information

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location Therma-Stor Products A Division of DEC International Box 8050 Madison, WI 53708 Toll Free 1-800-533-7533 Local 1-608-222-5301 PHOENIX 300 Operation & Service Instructions Table of Contents 1. Specifications...

More information

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Series Units RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING Improper installation, adjustment, alteration, service or maintenance can cause personal injury, loss of life,

More information

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2 Service Literature Corp. 0527 L10 Revised May 2011 CB26UH and CBX26UH Series Table of Contents CB26UH CBX26UH Model Number Information................... 2 Specifications / Electrical Data................

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ,t_2007 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR 505,264M (65484504) 10/07 Supersedes 09/06 COILS n _putech blications ical Litho U.S.A. RETAIN THESE

More information

Ruud Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N T-SERIES Air Conditioner T20 Model INSTRUCTION MANUAL Rev. C P/N 89114993 TABLE OF CONTENTS Warranty and Return Policy... 2 IMPORTANT NOTICE... 2 RECEIVING THE AIR CONDITIONER... 3 HANDLING AND TESTING

More information

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION HEAT PUMP OUTDOOR UNITS lps13dc DRY CHARGE UNITS PRODUCT SPECIFICATIONS Bulletin No. 210637 June 2014 Supersedes June 2012 1.5 to 5 Tons MODEL NUMBER IDENTIFICATION L P S 13 DC - 036-230 - 2 Lennox Minor

More information

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N SPECTRACOOL Air Conditioner N21 Model INSTRUCTION MANUAL Rev. G P/N 89115088 TABLE OF CONTENTS WARRANTY AND RETURN POLICY...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

48TM GAS HEATING/ELECTRIC COOLING UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS 48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER Air Handlers Rheem Air Handler RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RHAL- Series PSC Motor Efficiencies up to 14. SEER Front or Bottom Return Flow Check Piston for cooling or heat pump

More information

What is Included with a Seasonal Service?

What is Included with a Seasonal Service? What is Included with a Seasonal Service? Most of our Peace of Mind members add services like annual maintenance for their heating/cooling units, annual dryer vent cleaning, or even getting their gutters

More information

Air Conditioners (Outdoor)

Air Conditioners (Outdoor) 22/04/16 A1 Air Conditioners (Outdoor) Outdoor Condenser Units - R-410A Refrigerant Split System Air Conditioners, 208/230 Volt, Single Phase Copeland Scroll Compressor Micro-channel all aluminum coils

More information

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Rheem High Efficiency Modulating EcoNet Enabled Air Handler Air Handlers Series Rheem High Efficiency Modulating EcoNet Enabled Air Handler - Series Constant CFM (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 20.5 SEER The is EcoNet Enabled: This allows

More information

Ruud Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton G Series ENCASED/UNCASED AIR COILS Geothermal/Water Source Heat Pumps R-410A Refrigerant 2- Ton Dimensional Data G Series Air Coils Installation ti Manual Installation Information Maintenance IM1018AG1

More information

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001829 OPERATIONS AND MAINTENANCE MANUAL Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1.0 SCOPE: This Operations and Maintenance

More information

Manifold Gauge LD.R1.02 LD.R1.01. manifold gauge. manifold gauge. brass body. brass body LD.R1.04 LD.R1.03. manifold gauge.

Manifold Gauge LD.R1.02 LD.R1.01. manifold gauge. manifold gauge. brass body. brass body LD.R1.04 LD.R1.03. manifold gauge. Manifold Gauge LD.R1.01 manifold gauge brass body LD.R1.02 manifold gauge brass body LD.R1.03 manifold gauge aluminum body LD.R1.04 manifold gauge aluminum body LD.R1.05 manifold gauge aluminum body LD.R1.06

More information

INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for

INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for T-333 Manual INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for Rooftop Energy Storage Systems (ESS) AIR COOLING UNIT 77-62186-00 THRU -04 & 77-62203-00 T-333 REV. 03/2012 2012 Mobile Climate Control

More information

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGB SERIES 3thru5Ton 10 SEER C CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N PROAIR Air Conditioner CR23 Model INSTRUCTION MANUAL Rev. D P/N 89112522 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

Rheem Standard Efficiency Air Handler

Rheem Standard Efficiency Air Handler Air Handlers Rheem Standard Efficiency Air Handler RHSL- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001927 Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1 1.0 SCOPE: This

More information

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2AAA 2,000 Btuh.00 EER Right Side Control Panel 60Hz Green Refrigerant R-4A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information

Condensing Units & Air Handlers

Condensing Units & Air Handlers Condensing Units & Air Handlers 13 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice. Copyright

More information

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax AllStyle Coil Company, LP 7037 Brittmore Houston, TX 77041 Phone 713-466-6333 Fax 713-466-6363 April 2005 VL / VLX Series Air Handler VL / VLX Series Air Handlers Installation Operation Maintenance The

More information

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons) ENGINEERING DATA HEAT PUMP OUTDOOR UNITS HP40 50HZ Capacity 6.2 to 16.3 (21 200 to 55 500 Btuh) Heating Capacity 6.4 to 16.1 (21 800 to 55 500 Btuh) Bulletin No. 490088 October 2004 Supersedes August 1999

More information

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS CROWN Boiler Co Santa-Fe Series Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS These instructions must be affixed on or adjacent to the air handler Models: SAC049A20 SAC059A25

More information

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS Refrigerant R22 is widely used for residential and commercial air conditioning, as well as commercial refrigeration

More information

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration Calhoon MEBA Engineering School Study Guide for Proficiency Testing Refrigeration 1. To prevent an injury when working with refrigerants, what safety precautions are necessary? 2. When halogens are in

More information

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER FORM NO. HFJ-6 Supersedes Form No. PTZ-789 HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER Features The FH**TTT is EcoNet Enabled: This allows the FH**TTT to directly communicate with the EcoNet Smart

More information

SCN60 Residential Nugget Ice Machine

SCN60 Residential Nugget Ice Machine SCN60 Residential Nugget Ice Machine SCN60 Nugget Ice Nugget Ice What it isn t: Ice frozen in a mold What it is: A chewable ice, formed continuously by forcing soft ice thru tapered holes. Components Compared

More information

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features. Spot Cooling Systems, Inc. 120 Century Drive Suite 00 Carrollton, TX 7006 00-6-776 Operation Manual SCT1B and SCT1B Warning! Improper installation, adjustment, alteration, service, or maintenance can cause

More information

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet Air Conditioning and Heating SPECIFICATION sheet MHH 13 SEER High Efficiency R410a Split System Heat Pump Standard features: R410a system High efficiency compressor Compact design for easy installation

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model DS4BD Series M120 Product Line High Efficiency R-410A Air Conditioner 13+ SEER 1.5-5 Ton Capacity 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

VERTICAL FAN COIL UNITS

VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote

More information

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N PROAIR Air Conditioner CR43 Model INSTRUCTION MANUAL Rev. H P/N 10-1008-130 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS 13ACXN MERIT Series R-410A Bulletin No. 210831 January 2018 Supersedes Bulletin No. 210739 SEER up to 15.50 1.5 to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh

More information

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER IMPORTANT MASSAGE TO INSTALLER: "The United States Environmental Protection Agency ("EPA") has issued various regulations regarding the

More information

Refrigerant Recovery Unit, Model RRU134

Refrigerant Recovery Unit, Model RRU134 Installation, Operation & Maintenance Manual IOMM RRU134 Group: Refrigerant Effective: December 2000 Supersedes: New Refrigerant Recovery Unit, Model RRU134 1999 McQuay International Table of Contents

More information

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS 50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York

More information

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) CS*/CD*/CP* Series Air Cooled Condensing Units Operating and Installation Manual CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) TABLE OF CONTENTS I. Receipt of Equipment 2 II. Piping...4 III. System

More information

Introduction Terms and Conditions of Sale

Introduction Terms and Conditions of Sale Introduction Terms and Conditions of Sale PAGE Refrigerant Recovery Systems YJ- LTE Refrigerant Recovery System NEW 1 XLT Recovery Machine 2 Vacuum Pump Systems and Gauges BULLET Vacuum Pump 4 SuperEvac

More information

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999 TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO. 8801469 EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999 THE MILK COOLING SYSTEMS SPECIALISTS TM FRE-HEATER Part No. 8801469 Table

More information

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler Air Handlers Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler RHT- Series Constant Torque (ECM) Efficiencies up to 17 SEER The RHT is EcoNet Enabled: This allows the RHT to directly communicate

More information

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS EL6XC ELITE Series R-40A Bulletin No. 20833 July 208 Supersedes March 208 SEER up to 7.90.5 to 5 Tons Cooling Capacity - 7,800 to 60,000 Btuh MODEL NUMBER IDENTIFICATION

More information

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat) ENGINEERING DATA COILS BLOWER COIL UNITS B24/C22/24 B24 SERIES ADD-ON BLOWER UNITS UP-FLO DOWN-FLO HORIZONTAL WITH C22FC/CR22/CH22 & C24FC/CH24 COILS 1-1/2 Thru 5 Ton (5.3 thru 17.6 kw) Capacity 6,400

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler Air Handlers Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler RHT- Series Constant Torque (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 17 SEER The RHT is EcoNet Enabled: This allows

More information

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N T-SERIES Air Conditioner T43 Model INSTRUCTION MANUAL Rev. I P/N 10-1008-145 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING

More information

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986 ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED

More information

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

WALL-MOUNT HEAT PUMPS - (60HZ)

WALL-MOUNT HEAT PUMPS - (60HZ) WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to 5,000 Cooling Capacities:,00 to 5,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N PROAIR Air Conditioner CR29 Model INSTRUCTION MANUAL Rev. I P/N 89104461 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

SpaceKeeper Console (SKC)

SpaceKeeper Console (SKC) SpaceKeeper Console (SKC) With finished cabinet or custom enclosure SKC 008-015 ¾ - 1¼ tons 12 W x 25¼ H x 48 L CGC-09 SpaceKeeper Console R410A MODEL NO. SKC _ 008 010 012 015 Net Cooling Capacity - Rated

More information

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS 48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H3018-060A 2008 American Standard Heating & Air Conditioning PUB. NO. 12-1216-02 June 2008 Features and Benefits Duration compressor Efficiency up

More information