SUBMITTAL DATA BAYVIEW SENIOR CENTER. City of Pensacola. for. Sold to. Prepared for. Air-Tech / Darren Wood. Job Number: AZIK4A.

Size: px
Start display at page:

Download "SUBMITTAL DATA BAYVIEW SENIOR CENTER. City of Pensacola. for. Sold to. Prepared for. Air-Tech / Darren Wood. Job Number: AZIK4A."

Transcription

1 SUBMITTAL DATA for BAYVIEW SENIOR CENTER Sold to Prepared for City of Pensacola Job Number: AZIK4A Customer PO#: Prepared by Air-Tech / Darren Wood 6/6/2018 Job Name: BAYVIEW SENIOR CENTER 2 of 25

2 Technical Data Sheet for A CC-1 Technical Data Sheet for ACC-1 Job Information Job Name BAYVIEW SENIOR CENTER Date 6/6/2018 Submitted By Darren Wood Software Version Unit Tag ACC-1 Unit Overview Model Number Capacity ton IPLV.IP* EER Btu/W.h Technical Data Sheet Voltage Unit Starter Type Across the AGZ050E V / 60.0 Hz / 3 Ph Line * IPLV reflects AHRI standard rating conditions and does not change with user defined conditions. 1 Previously LEED EA Credit 4 Under LEED V2009 ASHRAE 90.1 '07, '10, '13 & '16 LEED Enhanced Refrigerant Management Credit 1 Pass Unit Water Volume: Connection Hand: Connection Size: Insulation: Entering Fluid Temperature Unit Type Platform Unit Revision Air-Cooled Scroll Compressor Chiller Packaged 00 Head Pressure VFD w/o Line Reactors [Low Ambient] Unit Controls Electronic Expansion Valve Refrigerant Type R410A Pump Controls Dual Evaporator Pumps - Dual Control Output Approval ETL/cETL, AHRI & ASHRAE 90.1 Evaporator 2.6 gal Left Hand Connections 2.5 in Single Layer Insulation to Suction at each Compressor Leaving Fluid Temperature Fluid Type F F Water Fluid Flow gpm Tubing Replaceable Filter Dryer with Discharge & Liquid Valves, no HGBP Fluid Flow Min / Max 72.5/ gpm Note: Evaporator Pressure Drop includes Factory Installed Strainer. Pressure drop without strainer is Coil Fins: Guards: MicroChannel (Epoxy Coating) Condenser Coil Wire Grilles only Condenser Display On Controller only Pressure Drop 20.3 ft H₂O Refrigerant Weight 46 lb (per unit) Pressure Drop Min / Max 6.20 / 40.0 ft H₂O Fouling Factor F.ft².h/Btu Design Ambient Air Temperature Altitude Fan Diameter Minimum Design Ambient Temperature 95.0 F ft 30.0 in 26.0 F Job Name: BAYVIEW SENIOR CENTER 4 of 25

3 Technical Data Sheet for ACC-1 Unit Performance Design Capacity Input Power Efficiency (EER) IPLV.IP* (EER) ton kw Btu/W.h Btu/W.h Point # % Load Capacity ton Performance Points rated at AHRI Ambient Relief Unit Evaporator Condenser Input Power Fluid Flow kw gpm Efficiency (EER) Btu/W.h Pressure Drop ft H₂O Entering Fluid Temperature F Leaving Fluid Temperature F Ambient Air Temperature F Altitude ft This load point is below the chiller minimum load This load point is below the chiller minimum load. * IPLV reflects AHRI standard rating conditions and does not change with user defined conditions Note: Evaporator Pressure Drop in this table does Not include strainer. For strainer pressure drop data see 'Evaporator' table on page 1. Sound (without insulation) Sound Pressure (at 30 feet) 63 Hz 125 Hz 250 Hz 500 Hz 1 khz 2 khz 4 khz 8 khz Overall 75% Load 50% Load 25% Load A A A A Sound Power 63 Hz 125 Hz 250 Hz 500 Hz 1 khz 2 khz 4 khz 8 khz Overall 75% Load 50% Load 25% Load A A A A Octave band is non 'A' weighted and overall readings are 'A' weighted. Sound data rated in accordance with AHRI Standard-370. Physical Unit Length* Height Width* Shipping Weight* Operating Weight* 94 in 100 in 88 in 3093 lb 3114 lb * Shipping and operating weights do not include the weights of any Options or Accessories. Contact Chiller Applications for additional information. Job Name: BAYVIEW SENIOR CENTER 5 of 25

4 Technical Data Sheet for ACC-1 Electrical Unit Electrical Data Voltage Starter Type Fan Motor Quantity LRA Fan Motor (each) FLA Fan Motors (each) 208 V / 60.0 Hz / 3 Ph Across the Line 4 23 A 5.8 A Power Connection Type: Short Circuit Current Rating: Phase Voltage: MCA: Fuse Size (recommended): Fuse Size (maximum): Connector Wire Range: Single Point Disconnect Switch with Circuit Protection 5 ka Phase & Under/Over Voltage Protection with LED A 250 A 250 A (2) 3/0-500MCM Single Point Power Connection Compressor Electrical Data Compressor Type Compressor Quantity Starter Type Scroll 4 Across the Line Circuit #: 1 2 Compressor #: RLA: 51.3 A 51.3 A 51.3 A 51.3 A Inrush Current: 300 A 300 A 300 A 300 A Note: Power wiring connections to the chiller may be done with either copper or aluminum wiring. Wire should be sized per NEC and/or local codes. Wire sizing and wire count must fit in the power connection lug sizing listed in latest installation manual. Please contact your local sales office for more information. Options Control Box Ambient: Suction Shut-off Valve: Evaporator Strainer: Communication: Ground Fault: Water Flow Indicator: Basic Unit High Ambient with Exhaust Fans (125ºF maximum) Included Factory Installed Evaporator Strainer 175 PSI Pressure Rating Control BACnet MS/TP Electrical Unit Ground Fault Protection Thermal Dispersion Type Warranty Unit Startup Standard Warranty: Extended Unit Warranty: Refrigerant Warranty By Others 1st Year Entire Unit Parts & Labor Entire Unit; Extended 4 years parts & labor (5 Years Total) 5 Years Total AHRI Certification Certified in accordance with the AHRI Air-Cooled Water-Chilling Packages Using Vapor Compression Cycle Certification Program, which is based on AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI). Certified units may be found in the AHRI Directory at Accessories Part Number Optional Description RIS Isolator Kit; AGZ: Packaged, Microchannel,Al&Cu Fins, E (non-seismic),25-65d,30-65c; M'Chnl,75-100E (non-s'mc); Al Fin,70C/D;Remote,Al&Cu Fin,30-70E (non-s'mc); Pump Pkg, M'Chnl&Al Fin,30-65E (non-s'mic); Cu Fin,30-55E(non-S'mic) Job Name: BAYVIEW SENIOR CENTER 6 of 25

5 Item Summary for ACC-1 Item Summary for ACC-1 Job: BAYVIEW SENIOR CENTER Model: AGZ050E Date: 6/6/2018 Tag: ACC-1 Version: Unit Options: Code Code Item Value Description 1 AGZ UNIT TYPE; AIR COOLED SCROLL CHILLER 2 050E UNIT SIZE; 050E 3 D NUMBER OF COMPRESSORS; 2 Compressors per Circuit 4 SE PLATFORM; Standard Package - Standard Eff. 5 FP CONSTRUCTION; Fully Painted (with Unit Wraps) 6 ST SOUND; Standard Sound 7 S UNIT OPERATION; Standard Operation (40F-50F LWT) 8 P CONDENSER COIL FINS; MicroChannel (Epoxy Coating) 9 AL COMPRESSOR STARTER; Across the Line 10 Y FUTURE; Future VOLTAGE; 208V/60HZ/3PH 12 DC POWER CONNECTION; Single Point Disconnect Sw. & Circuit Protection 13 V PHASE VOLTAGE; Phase & Under/Over Voltage Protection w/ LED 14 N FUTURE; None 15 H CONTROL BOX AMBIENT; With Exhaust Fans & Vents 16 N COMPRESSOR CAPACITOR; None 17 BT COMMUNICATION; Intelligent Equipment & BACnet MS/TP 18 N DISPLAY OPTIONS; On Controller Only 19 G GROUND FAULT; W/ Ground Fault Protection for the Unit 20 Y FUTURE; Future 21 N UNIT OPTIONS; No Unit Options 22 B WATER FLOW; Factory Installed Strainer & Flow Indication 23 LH EVAPORATOR CONNECTION; Left Hand Connections 24 B EVAPORATOR INSULATION; Single Layer Insulation to Suction at each Compr. 25 E UNIT CONTROLS; Electronic Expansion Valve 26 L FANS; Standard Low Noise Fan Motors 27 D HEAD PRESSURE; VFD without Line Reactors 28 G GUARDS; Condenser Coil Wire Grilles only 29 VN TUBING OPTIONS; Repl. Filter Dyer, w/ Disch. & Liq. Valves, No HG 30 V SUCTION VALVE; Shut-off Valve 31 NN WATER PUMP; None 32 NNNN PUMP TYPE; No Pump Package 33 N FACTORY USE ONLY; N/A PUMP FLOW; Gallons per minute TOTAL HEAD; Feet 36 N PUMP PACKAGE STARTER; None 37 N PUMP GAUGES; None 38 N PUMP SUCTION VALVE; None 39 N PUMP DISCHARGE VALVE; None 40 Y FUTURE; Future 41 NNNN IMPELLER TRIM; None 42 NN EXPANSION TANK; None 43 NN BUFER TANK; None PERCENT OF GLYCOL; None PUMP PART NUMBER; Pump Package Part Number 46 E APPROVALS; ETL/CETL, AHRI & ASHRAE N CRN EVAPORATOR; None 48 NSU UNIT START; Startup by Others Job Name: BAYVIEW SENIOR CENTER 8 of 25

6 Item Summary for ACC-1 Code Code Item Value Description 49 DPN STANDARD WARRANTY; Domestic, 1 Year Standard Warranty-Parts Only 50 Y FUTURE; Future 51 NNNN EXT COMPRESSOR WARRANTY; None - No Extended Compressor Warranty 52 AE1 FIRST YEAR LABOR WARRANTY; Entire Unit 53 EBE4 EXTENDED UNIT WARRANTY; Entire Unit - Ext. 4 Year Parts & Labor 54 RA5 REFRIGERANT WARRANTY; 5 Year R410A Refrigerant 55 D00 DELAYED WARRANTY START; Additional Months:0 [12-18] Standard 56 D2 FIELD OPTIONS; Dual Evaporator Pumps - Dual Control Output 57 J BRAND NAME; Daikin 58 S SHIP; Standard Ship 59 NN RESTART; Standard 60 Y FUTURE; Future 61 S UNIT MISC; Standard Unit UNIT REVISION; Major Unit Change Revision 63 B SHIPPING/PACKAGING; Bagged 64 F0 TESTING; Functional Test Accessories: Part Number Description Qty Ext Qty RIS Isolator Kit; AGZ: Packaged, Microchannel,Al&Cu Fins, E (non- Seismic),25-65D,30-65C; M'Chnl,75-100E (non- S'mc); Al Fin,70C/D;Remote,Al&Cu Fin,30-70E (non-s'mc); Pump Pkg, M'Chnl&Al Fin,30-65E (non-s'mic); Cu Fin,30-55E(non-S'mic) 1 1 Job Name: BAYVIEW SENIOR CENTER 9 of 25

7 AGZ-E Cl ose S paci ng_drawi ng for AC C-1 AGZ-E Close Spacing_Drawing for ACC-1 AGZ-E Close Spacing Performance Case 1: Building or Wall on One Side of Unit Assumes a solid height wall taller than unit. Refer to Case 4 for partial wall openings. Building or Wall on One Side of Unit For models AGZ E, maintain a 4 feet minimum from a wall of any height. For models AGZ E, maintain a 6 feet minimum from a wall of any height. For models AGZ E, maintain an 8 feet minimum from a wall of any height. 0A Case 2: Two Units, Side-by-Side For models , there must be a minimum of 4 feet between two units placed side-by-side; however, performance may be affected at this distance. For models , the minimum is 6 feet as closing spacing may cause air recirculation and elevated condenser pressure. Assuming the requirement of one side having at least 8 feet of service clearance is met, Case 2 figures show performance adjustments as the distance between two units increases. Two Units, Side-by-Side Case 2 - Full Load Capacity Reduction Case 2 Power Increase Product Drawing Unit Tag: ACC-1 Product: Air-Cooled Scroll Chiller Project Name: BAYVIEW SENIOR CENTER Model: AGZ-E Sales Office: Air-Tech of Pensacola Sales Engineer: Darren Wood June 06, 2018 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-1.0 Dwg Units: in [mm] Industrial Park Blvd. Minneapolis, MN Software Version: No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Name: BAYVIEW SENIOR CENTER 10 of 25

8 AGZ-E Close Spacing_Drawing for ACC-1 Case 3: Three or More Units, Side-by-Side For all models, there must be a minimum distance between any units placed side-by-side; however, performance may be affected at this distance. Minimum distances are: models 030 to feet, models 075 to feet, models 110 to feet. The Case 3 charts below depict Case 3 performance adjustments as the distance between units increases. Data shown is for the middle unit with a unit on each side. See Case 2 adjustment factors for the two outside units. Three or More Units, Side-by-Side Case 3 Full Load Capacity Reduction Case 3 Power Increase Job Name: BAYVIEW SENIOR CENTER 11 of 25

9 AGZ-E Close Spacing_Drawing for ACC-1 Case 4: Open Screening Walls Decorative screening walls are often used to help conceal a unit either on grade or on a rooftop. When possible, design these walls such that the combination of their open area and distance from the unit (see chart below) do not require performance adjustment. If the wall opening percentage is less than recommended for the distance to the unit, it should be considered as a solid wall. It is assumed that the wall height is equal to or less than the unit height when mounted on its base support. If the wall height is greater than the unit height, see Case 5: Pit Installation for performance adjustment factors. The distance from the sides of the unit to the side walls must be sufficient for service, such as opening control panel doors. For uneven wall spacing, the distance from the unit to each wall can be averaged providing no distance is less than 4 feet. Values are based on walls on all four sides. Case 4 - Allowable Wall Open Area Case 5: Pit Installation Pit installations can cause operating problems resulting from air recirculation and restriction and require care that sufficient air clearance is provided, safety requirements are met and service access is provided. A solid wall surrounding a unit is substantially a pit and this data should be used. Steel grating is sometimes used to cover a pit to prevent accidental falls or trips into the pit. The grating material and installation design must be strong enough to prevent such accidents, yet provide abundant open area to avoid recirculation problems. Have any pit installation reviewed by the Daikin Applied sales representative prior to installation to ensure it has sufficient air-flow characteristics and approved by the installation design engineer to avoid risk of accident. Models AGZ E: The Case 5 figures for models AGZ E show adjustment factors for pit/wall heights of 4 feet, 5 feet, and 6 feet. Case 5 - Full Load Capacity Reduction and Power Increase (AGZ030E-070E) Case 5- Pit Installation KEY: : Power Increase : Capacity Reduction Job Name: BAYVIEW SENIOR CENTER 12 of 25

10 AGZ-E Close Spacing_Drawing for ACC-1 Models AGZ E: The Case 5 figures for models AGZ E show adjustment factors for pit/wall heights of 5 feet, 6 feet, and 8 feet. Case 5 - Full Load Capacity Reduction and Power Increase (AGZ E) KEY: : Power Increase : Capacity Reduction Models AGZ E: The Case 5 figures for models AGZ E show adjustment factors for pit/wall heights of 6 feet, 8 feet, and 10 feet. Case 5 - Full Load Capacity Reduction (AGZ E) Case 5 - Power Increase (AGZ E) Case 5 - Full Load Capacity Reduction (AGZ E) Case 5 - Power Increase (AGZ E) Job Name: BAYVIEW SENIOR CENTER 13 of 25

11 AGZ E_ CndGrl_wr ps_ Drawing for A CC -1 Job Number: Job Name: AZIK4A BAYVIEW SENIOR CENTER 14 of 25 Page Prepared Date: 6/6/2018 AGZ-E Guards: Condenser Coil Wire Grilles, Front and Rear Wraps, Painted Base Product Drawing Unit Tag: ACC-1 Sales Office: Air-Tech of Pensacola Product: Air-Cooled Scroll Chiller Project Name: BAYVIEW SENIOR CENTER Sales Engineer: Darren Wood Model: AGZ E June 06, 2018 Ver/Rev: Sheet: 1 of 1 Scale: N/A Tolerance: N/A Dwg Units: N/A Diagram Notes Diagram simulates wrap, grille and louver options as selected only. Refrigeration components may vary depending on selected options Industrial Park Blvd. Minneapolis, MN Software Version: No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. 00 AGZ E_CndGrl_wrps_Drawing for ACC-1

12 AGZ050E_ PKG_MCC_Draw ing for ACC-1 Job Number: Job Name: AZIK4A BAYVIEW SENIOR CENTER 15 of 25 Page Prepared Date: AGZ050E Packaged (Microchannel Condenser) Unit Dimensions Units Unit Weight Data Weight Lifting Weight Mounting Weight Shipping Operating L1 L2 L3 L4 M1 M2 M3 M4 lb kg Units A (No Strainer) Unit and Center of Gravity Dimensions B (With Strainer) Connection Size (Victaulic) Center of Gravity X Y Z in mm NOTE IT IS RECOMMENDED THAT THE SIDE LOCATIONS BE USED FOR POWER ENTRY WIRE SIZES LARGER THAN 350 MCM. NOTE A water strainer must be installed at the inlet of the evaporator to protect it from damage. Please refer to the IOM for additional details. 0A AGZ050E_PKG_MCC_Drawing for ACC-1 6/6/2018 Product Drawing Unit Tag: ACC-1 Sales Office: Air-Tech of Pensacola Product: Air-Cooled Scroll Chiller Project Name: BAYVIEW SENIOR CENTER Sales Engineer: Darren Wood Model: AGZ050E June 06, 2018 Ver/Rev: Sheet: 1 of 1 Scale: NTS Tolerance: +/- 1.0" Dwg Units: in [mm] Industrial Park Blvd. Minneapolis, MN Software Version: No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

13 AGZE_Cleara nce_mcc_dra wing for ACC-1 Job Number: Job Name: AZIK4A BAYVIEW SENIOR CENTER AGZ-E Service Clearance 0B AGZE_Clearance_MCC_Drawing for ACC-1 16 of 25 Page Prepared Date: *NOTE: Additional clearance is required for proper airflow. Please consult Close Spacing drawings and IOM for additional details. 6/6/2018 Product Drawing Unit Tag: ACC-1 Sales Office: Air-Tech of Pensacola Product: Air-Cooled Scroll Chiller Project Name: BAYVIEW SENIOR CENTER Sales Engineer: Darren Wood Model: AGZ-E June 06, 2018 Ver/Rev: Sheet: 1 of 1 Scale: NTS Tolerance: +/- 1.0" Dwg Units: in [mm] Industrial Park Blvd. Minneapolis, MN Software Version: No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

14 IsoKit_RIS_ _Drawi ng for ACC-1 Job Number: Job Name: AZIK4A BAYVIEW SENIOR CENTER Rubber-in-Shear (RIS) Isolator Kit Dimensions and Placement Mounting Location M1 M2 M3 M4 Brown Brown Brown Brown M3 M1 00 IsoKit_RIS_ _Drawing for ACC-1 17 of 25 Page Prepared Date: M4 Control Panel M2 6/6/2018 Product Drawing Unit Tag: ACC-1 Sales Office: Air-Tech of Pensacola Accessory: Rubber-in-Shear (RIS) Isolator Kit Project Name: BAYVIEW SENIOR CENTER Sales Engineer: Darren Wood Kit Part Number: June 06, 2018 Ver/Rev: Sheet: 1 of 1 Scale: NTS Tolerance: +/- 1.0" Dwg Units: in [mm] Industrial Park Blvd. Minneapolis, MN Software Version: No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

15 FieldWiri ng_agze_s P_Drawi ng for AC C-1 FieldWiring_AGZE_SP_Drawing for ACC-1 AGZ E Single-Point Connection Field Wiring Diagram 0D Field Wiring Diagram Unit Tag: ACC-1 Product: Air-Cooled Scroll Project Name: BAYVIEW SENIOR CENTER Model: AGZ E Single-Point Sales Office: Air-Tech of Pensacola Sales Engineer: Darren Wood June 06, 2018 Ver/Rev: Sheet 1 of 1 Scale: N/A Tolerance: N/A Dwg Units: N/A Industrial Park Blvd. Minneapolis, MN Software Version: No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Name: BAYVIEW SENIOR CENTER 18 of 25

16 Specificati on for A CC -1 Specification for ACC-1 PART 1: GENERAL 1.01 SUMMARY A. Section includes design, performance criteria, refrigerants, controls, and installation requirements for air-cooled scroll compressor chillers REFERENCES A. Comply with applicable Standards/Codes of AHRI 550/590, ANSI/ASHRAE 15, ETL, cetl, NEC, and OSHA as adopted by the State. B. Units shall meet the efficiency standards of the current version of ASHRAE Standard 90.1, and FEMP standard SUBMITTALS A. Submit shop drawings and product data in accordance with the specifications. B. Submittals shall include the following: 1. Dimensioned plan and elevation view drawings, required clearances, and location of all field connections 2. Summary of all auxiliary utility requirements such as electricity, water, etc. Summary shall indicate quality and quantity of each required utility. 3. Single line schematic drawing of the field power hookup requirements, indicating all items that are furnished. 4. Schematic diagram of control system indicating points for field interface/connection. 5. Diagram shall fully delineate field and factory wiring. 6. Installation and operating manuals QUALITY ASSURANCE A. Qualifications: Equipment manufacturer must specialize in the manufacture of the products specified and have five years experience with the type of equipment and refrigerant offered. B. Regulatory Requirements: Comply with the codes and standards specified. C. Chiller manufacturer plant must be ISO Registered DELIVERY AND HANDLING A. Chiller shall be delivered to the job site completely assembled and charged with refrigerant and oil by the manufacturer. B. Comply with the manufacturer's instructions for rigging and handling equipment WARRANTY A. Standard Warranty (Domestic): The refrigeration equipment manufacturer's guarantee shall be for a period of one year from date of equipment start-up but not more than 18 months from shipment. The guarantee shall provide for repair or replacement due to failure by material and workmanship that prove defective within the above period, excluding refrigerant. B. 1st Year Labor Warranty: Entire unit C. Extended Compressor Warranty: None. D. Extended Unit Warranty: Entire unit (no pumps), four (4) years parts and labor. E. Refrigerant Warranty: Five (5) years R410A refrigerant. F. Delay Warranty Start: None MAINTENANCE A. Maintenance of the chillers shall be the responsibility of the owner and performed in accordance with the manufacturer s instructions. PART 2: PRODUCTS Job Name: BAYVIEW SENIOR CENTER 19 of 25

17 Specification for ACC ACCEPTABLE MANUFACTURERS A. Daikin Applied B. (Approved Equal) 2.02 UNIT DESCRIPTION A. Provide and install as shown on the plans factory-assembled, factory-charged air-cooled scroll compressor packaged chillers in the quantity specified. Each chiller shall consist of hermetic tandem scroll compressor sets (total four compressors), brazed plate evaporator, air-cooled condenser section, microprocessor-based control system and all components necessary for controlled unit operation. B. Chiller shall be functionally tested at the factory to ensure trouble free field operation 2.03 DESIGN REQUIREMENTS A. Flow Range: The chiller shall have the ability to support variable flow range down to 40% of nominal design (based on AHRI conditions). B. Operating Range: The chiller shall have the ability to control leaving chilled fluid temperature from 15F to 65F. C. General: Provide a complete scroll compressor packaged chiller as specified herein and as shown on the drawings. The unit shall be in accordance with the standards referenced in section 1.02 and any local codes in effect. D. Performance: Refer to the schedule of performance on the drawings. The chiller shall be capable of stable operation to a minimum percentage of full load (without hot gas bypass) of 25%. Performance shall be in accordance with AHRI Standard 550/590. E. Acoustics: Sound pressure levels for the unit shall not exceed the following specified levels. All manufacturers shall provide the necessary sound treatment ( parts and labor) to meet these levels if required. Sound data shall be provided with the quotation. Test shall be in accordance with AHRI Standard CHILLER COMPONENTS A. Compressor 1. The compressors shall be sealed hermetic, scroll type with crankcase oil heater and suction strainer. The compressor motor shall be refrigerant gas cooled, high torque, hermetic induction type, two-pole, with inherent thermal protection on all three phases and shall be mounted on RIS vibration isolator pads. The compressors shall be equipped with an internal module providing compressor protection and communication capability. B. Evaporator 1. The evaporator shall be a compact, high efficiency, dual circuit, brazed plate-to-plate type heat exchanger consisting of parallel stainless steel plates. 2. The evaporator shall be protected with an external, electric resistance heater plate and insulated with 3/4" (19mm) thick closed-cell polyurethane insulation. This combination shall provide freeze protection down to -20 F (-29 C) ambient air temperature. 3. The water-side maximum design pressure shall be rated at a minimum of 653 psig (4502 kpa). Evaporators shall be designed and constructed according to, and listed by Underwriters Laboratories (UL). C. Condenser Job Name: BAYVIEW SENIOR CENTER 20 of 25

18 Specification for ACC-1 1. Condenser fans shall be propeller type arranged for vertical air discharge and individually driven by direct-drive fan motors. The fans shall be equipped with a heavy-gauge vinyl-coated fan guard. Fan motors shall be TEAO type with permanently lubricated ball bearings, inherent overload protection, three-phase, direct-drive, 1140 rpm. Each fan section shall be partitioned to avoid cross circulation. 2. Coil shall be microchannel design and shall have a series of flat tubes containing multiple, parallel flow microchannels layered between the refrigerant manifolds. Tubes shall be 9153 aluminum alloy. Tubes made of 3102 alloy or other alloys of lower corrosion resistance shall not be accepted. Coils shall consist of a two-pass arrangement. Each condenser coil shall be factory leak tested with high-pressure air under water. Condenser coils shall include baked epoxy coating providing hour salt spray resistance (ASTM B117-90) applied to both the coil and the coil frames. D. Refrigerant Circuit 1. Each of the two refrigerant circuits shall include a replaceable-core refrigerant filter-drier, sight glass with moisture indicator, liquid line solenoid valve (no exceptions), expansion valve, and insulated suction line. E. Construction 1. Unit casing and all structural members and rails shall be fabricated of pre-painted or galvanized steel. Painted parts shall be able to meet ASTM B117, 1000-hour salt spray test. 2. Upper condenser coil section of unit shall have protective, 12 GA, PVC-coated, wire grille guards. F. Control System 1. A centrally located weatherproof control panel shall contain the field power connection points, control interlock terminals, and control system. Box shall be designed in accordance with NEMA 3R rating. Power and starting components shall include factory circuit breaker for fan motors and control circuit, individual contactors for each fan motor, solid-state compressor three-phase motor overload protection, inherent fan motor overload protection and two power blocks (one per circuit) for connection to remote, contractor supplied disconnect switches. Hinged access doors shall be lockable. Barrier panels or separate enclosures are required to protect against accidental contact with line voltage when accessing the control system. 2. Shall include optional single-point connection to a non-fused disconnect switch with through-the-door handle and compressor circuit breakers. G. Unit Controller 1. An advanced DDC microprocessor unit controller with a 5-line by 22-character liquid crystal display provides the operating and protection functions. The controller shall take preemptive limiting action in case of high discharge pressure or low evaporator pressure. The controller shall contain the following features as a minimum: 2. The unit shall be protected in two ways: (1) by alarms that shut the unit down and require manual reset to restore unit operation and (2) by limit alarms that reduce unit operation in response to some out-of-limit condition. Shut down alarms shall activate an alarm signal. 3. Shutdown Alarms a. No evaporator water flow (auto-restart) b. Sensor failures c. Low evaporator pressure d. Evaporator freeze protection e. High condenser pressure f. Outside ambient temperature (auto-restart) g. Motor protection system h. Phase voltage protection (Optional) 4. Limit Alarms a. Condenser pressure stage down, unloads unit at high discharge pressures. b. Low ambient lockout, shuts off unit at low ambient temperatures. c. Low evaporator pressure hold, holds stage #1 until pressure rises. d. Low evaporator pressure unload, shuts off one compressor. 5. Unit Enable Section Job Name: BAYVIEW SENIOR CENTER 21 of 25

19 Specification for ACC-1 a. Enables unit operation from either local keypad, digital input, or BAS 6. Unit Mode Selection a. Selects standard cooling, ice, glycol, or test operation mode 7. Analog Inputs: a. Reset of leaving water temperature, 4-20 ma\ b. Current Limit 8. Digital Inputs a. Unit off switch b. Remote start/stop c. Flow switch d. Ice mode switch, converts operation and setpoints for ice production e. Motor protection 9. Digital Outputs a. Shutdown alarm; field wired, activates on an alarm condition, off when alarm is cleared b. Evaporator pump; field wired, starts pump when unit is set to start 10. Condenser fan control - The unit controller shall provide control of condenser fans based on compressor discharge pressure. 11. Building Automation System (BAS) Interface a. Factory mounted DDC controller(s) shall support operation on a BACnet, Modbus or LONMARK network via one of the data link / physical layers listed below as specified by the successful Building Automation System (BAS) supplier. b. BACnet MS/TP master (Clause 9) c. BACnet IP, (Annex J) d. BACnet ISO , (Ethernet) e. LONMARK FTT-10A. The unit controller shall be LONMARK certified. f. The information communicated between the BAS and the factory mounted unit controllers shall include the reading and writing of data to allow unit monitoring, control and alarm notification as specified in the unit sequence of operation and the unit points list. g. For chillers communicating over a LONMARK network, the corresponding LONMARK external Interface File (XIF) shall be provided with the chiller submittal data. h. All communication from the chiller unit controller as specified in the points list shall be via standard BACnet objects. Proprietary BACnet objects shall not be allowed. BACnet communications shall conform to the BACnet protocol (ANSI/ASHRAE ). A BACnet Protocol Implementation Conformance Statement (PICS) shall be provided along with the unit submittal OPTIONS AND ACCESSORIES A. The following options are to be included: 1. CLOUD-ENABLED EQUIPMENT a. SYSTEM DESCRIPTION: The manufacturer shall provide an equipment management solution, which is factoryinstalled on the HVAC unit. Equipment hardware shall include integrated equipment power measurement and consist of all components necessary to deliver unit controller and power data directly to the cloud. The subscription-based Software as a Service (SaaS) shall allow remote HVAC monitoring, remote HVAC control, preventative maintenance recommendations, and unit commissioning/re-commissioning capabilities using secure, cloud-communicating hardware. The solution shall be capable of communicating to a user device (smart phone, tablet, etc.) via both wireless (cellular, Wi-Fi) and local area network (LAN) connection. All data is stored in the cloud for a minimum of 2 years. b. CLOUD-COMMUNICATING SMART DEVICE: 1) A factory-installed, tested and commissioned cloudcommunicating smart device shall deliver data to the cloud via wireless (Wi-Fi, cellular) or local area network (LAN) connection. 2) The cloud-communicating smart device shall implement security, to include: Job Name: BAYVIEW SENIOR CENTER 22 of 25

20 Specification for ACC-1 PART 3: EXECUTION c. Data delivery via secure HTTPS using SSL d. Virus and Malware protection e. Boot-level security f. Compliance: g. CE h. FCC Class A/Industry Canada i. UL60950 Carrier Approved j. INTEGRATED POWER METER: A factory-installed, tested and commissioned power meter shall monitor unit voltage, current, and power and transmit this data to the cloud-communicating smart device, for delivery to the cloud or shall deliver directly to the cloud. Hardware shall: k. Allow monitoring of single-phase, split-phase and 3-phase Y & Delta connections up to 600VAC (45-65 Hz) and up to 1000A l. Be UL /CSA C22.2 No and UL/CSA UL recognized 2. Low Ambient Control: Fan VFD allows unit operation from 32 F down to -10 F (-23.3 C). 3. Ground Fault Protection: Factory installed circuit breaker to protect equipment from damage from line-toground fault currents less than those required for conductor protection. 4. Phase loss with under/over voltage protection and with LED indication of the fault type to guard against compressor motor burnout. 5. The following accessories, if selected, are to be included: a. Spring vibration isolators for field installation b. Rubber-in-shear vibration isolators for field installation c. Factory-mounted thermal dispersion type flow switch d. Field-mounted, paddle type, chilled water flow switch field wired to the control panel e. Wye strainer, to be installed at the evaporator inlet and sized for the design flow rate, with perforation diameter of 0.063" with blowdown valve and Victaulic couplings (factory mounted or field installed) f. 115V GFI convenience outlet B. Optional Factory-Installed Pump Package: None 1. These pump package accessories, if selected, will also be included: a. Water pressure gauges on the pump suction and discharge b. Expansion tank with size increments from 4.4 to 90 gallons, field installed (small sizes can be factory mounted c. Air separator with air vent, field installed d. Storage tanks, vertical, insulated, 150, 300, 600, 1000 gallon sizes with optional immersion heater, field installed INSTALLATION A. Antenna, or equivalent, if needed, shall be shipped loose from the factory, and shall be mounted and electricallyconnected in the field by the contractor providing unit start-up and commissioning, per factory-supplied installation literature. For sites using Local Area Network (LAN) connection to provide cloud access, appropriate trades should coordinate to supply all necessary roof penetrations, conduit, network cable, network infrastructure, and termination to the network B. Install in strict accordance with manufacturer s requirements, shop drawings, and contract documents. C. Adjust and level chiller in alignment on supports. D. Coordinate electrical installation with electrical contractor. E. Coordinate controls with control contractor. F. Install a field-supplied or optional manufacturer-supplied strainer in the chilled water return line at the evaporator inlet that meets manufacturer perforation size specifications. Job Name: BAYVIEW SENIOR CENTER 23 of 25

21 Specification for ACC START-UP A. Initial programming of cloud-communicating smart device and integrated power meter shall be performed at the factory. Commissioning technician will submit the startup and commission documentation through the User Interface. B. Provide testing and starting of machine, and instruct the Owner in its proper operation and maintenance. Job Name: BAYVIEW SENIOR CENTER 24 of 25

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers Models RCS 025C through 135C 25 to 135 Tons R-22/R407C Refrigerant Catalog 221-1 Table of Contents Introduction.... 3 The Condensing

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers Catalog 221-1 Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers Model RCS 025C to 135C R-22/R-407C Refrigerant Contents Introduction............................... 3 The Condensing

More information

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Page 236423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified by MSU Physical Plant

More information

SECTION ROTARY-SCREW WATER CHILLERS

SECTION ROTARY-SCREW WATER CHILLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.

More information

RECORD SUBMITTAL COVER SHEET

RECORD SUBMITTAL COVER SHEET RECORD SUBMITTAL COVER SHEET PROJECT TITLE: AXCELLERATE PHARMA EQUIPMENT DESCRIPTION: CARRIER AQUASNAP AIR-COOLED CHILLER CH-1 OWNER: AXCELLERATE PHARMA MECHANICAL ENGINEER: ARDEN DATE: JUNE 27, 2014 SUBMITTED

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

Air-Cooled Split System Condensing Units for Remote DX Coils and Air Handlers. Models RCS 015D to 140D R-410A Refrigerant.

Air-Cooled Split System Condensing Units for Remote DX Coils and Air Handlers. Models RCS 015D to 140D R-410A Refrigerant. Air-Cooled Split System Condensing Units for Remote DX Coils and Air Handlers Models RCS 015D to 140D R-410A Refrigerant Catalog 222-5 Introduction.... 3 The Condensing Unit for Applied Rooftop and Air

More information

Call us today! (800)

Call us today! (800) 500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

.2 Section Waste Management and Disposal.

.2 Section Waste Management and Disposal. Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES 60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,

More information

SECTION AIR COOLED WATER CHILLERS

SECTION AIR COOLED WATER CHILLERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Chiller package B. Charge of refrigerant and oil C. Controls and control connections D. Chilled water connections E. Starters F. Electrical power connections 1.2

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

Call us today! (800)

Call us today! (800) 150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

Call us today! (800)

Call us today! (800) PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller

More information

Submittal. Date: September 04, Customer P.O. Number: Customer Project Number:

Submittal. Date: September 04, Customer P.O. Number: Customer Project Number: Submittal Prepared For: All Bidders Sold To: Date: September 04, 2012 Customer P.O. Number: Customer Project Number: Job Number: Job Name: DCS 12473 80 Ton Chiller Dept of Wildlife 1801 N Lincoln OKLAHOMA

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof

More information

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program. 15684 ROTARY SCREW WATER CHILLERS ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 236423 An optional

More information

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X Product Data Catalog Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X Variable Speed Total Access Modules MS010W, MS020W, MS030W, MS050W MS010V, MS020V,

More information

SECTION AIR COOLED WATER CHILLERS (LESS THAN 150 TONS)

SECTION AIR COOLED WATER CHILLERS (LESS THAN 150 TONS) SECTION 23 64 01 AIR COOLED WATER CHILLERS (LESS THAN 150 TONS) PART 1: GENERAL 1.1 GENERAL A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish

More information

Air Cooled Scroll Compressor Condensing Unit

Air Cooled Scroll Compressor Condensing Unit Replacement Parts List No. 70000900 Rev. B 2/08 Air Cooled Scroll Compressor Condensing Unit ACZ Sizes: 00-039 Vintage: B R22, R407C Contents Contents... 2 Parts List Revision History... 3 Nomenclature

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X Air Cooled Medical Chiller Product Data Catalog Product Introduction Multistack products are ideal for many mission

More information

Trailblazer Air-Cooled Scroll Compressor Chillers. Model AGZ, E Vintage 030 to 180 Tons (100 to 630 kw) HFC-410A Refrigerant 60/50 Hz.

Trailblazer Air-Cooled Scroll Compressor Chillers. Model AGZ, E Vintage 030 to 180 Tons (100 to 630 kw) HFC-410A Refrigerant 60/50 Hz. Trailblazer Air-Cooled Scroll Compressor Chillers Model AGZ, E Vintage 030 to 180 Tons (100 to 630 kw) HFC-410A Refrigerant 60/50 Hz Catalog 624-4 Table of Contents Table of Contents Introduction.... 3

More information

Water-Cooled & Remote Air-Cooled Scroll Compressor Chillers CZW, CZR, CTW, CTR Models

Water-Cooled & Remote Air-Cooled Scroll Compressor Chillers CZW, CZR, CTW, CTR Models CATALOG Water-Cooled & Remote Air-Cooled Scroll Compressor Chillers CZW, CZR, CTW, CTR Models 2.5 30 Tons, 8.8 105.5 kw 60 Hz, R410A Page 2 of 52 Table of Contents Introduction... 3 Chiller Model Number

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

Trailblazer Air-Cooled Scroll Compressor Chillers. Model AGZ, E Vintage 030 to 180 Tons (100 to 630 kw) HFC-410A Refrigerant 60/50 Hz.

Trailblazer Air-Cooled Scroll Compressor Chillers. Model AGZ, E Vintage 030 to 180 Tons (100 to 630 kw) HFC-410A Refrigerant 60/50 Hz. Trailblazer Air-Cooled Scroll Compressor Chillers Model AGZ, E Vintage 030 to 180 Tons (100 to 630 kw) HFC-410A Refrigerant 60/50 Hz Catalog 624-3 Table of Contents Table of Contents Introduction.... 3

More information

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil. 1 1 1 1 1 1 1 1 0 1 0 1 SECTION 1 PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES A. Chiller package. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled

More information

PACKAGED AIR COOLED Product Data Catalog

PACKAGED AIR COOLED Product Data Catalog PACKAGED AIR COOLED Product Data Catalog MODELS ASP-10A ASP-15A ASP-20A ASP-00P ASP-00F ASP-00G A MEMBER OF MARDUK HOLDING COMPANY, LLC The Leader in Modular Chillers ETL and CSA Approved CHILLER MODULES

More information

Pathfinder Air Cooled Screw Chillers. Model AWV, A Vintage 165 to 550 Tons (580 to 1935 kw) HFC-134a Refrigerant 60/50 Hz.

Pathfinder Air Cooled Screw Chillers. Model AWV, A Vintage 165 to 550 Tons (580 to 1935 kw) HFC-134a Refrigerant 60/50 Hz. Pathfinder Air Cooled Screw Chillers Model AWV, A Vintage 165 to 550 Tons (580 to 1935 kw) HFC-134a Refrigerant 60/50 Hz Catalog 626-3 Table of Contents Table of Contents Introduction.... 3 Features and

More information

Pathfinder Air Cooled Screw Chillers. Model AWV, A Vintage 165 to 350 Tons (580 to 1230 kw) HFC-134a Refrigerant 60/50 Hz.

Pathfinder Air Cooled Screw Chillers. Model AWV, A Vintage 165 to 350 Tons (580 to 1230 kw) HFC-134a Refrigerant 60/50 Hz. Pathfinder Air Cooled Screw Chillers Model AWV, A Vintage 165 to 350 Tons (580 to 1230 kw) HFC-134a Refrigerant 60/50 Hz Catalog 626 Table of Contents Table of Contents Introduction.... 3 Features and

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. General: 1. Design and specify refrigeration systems and equipment in accordance with "Energy Conservation Standards" stipulated in Section 15010, Basic

More information

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program. 15682 CENTRIFUGAL WATER CHILLERS ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 236416 An optional

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

LC Series Chillers. Engineering Catalog. Air-Cooled Condenser

LC Series Chillers. Engineering Catalog. Air-Cooled Condenser LC Series Chillers Engineering Catalog Air-Cooled Condenser Table of Contents Features and Benefits... 5 Application Information... 7 Unit Selection... 11 Evaporator Pressure Drops... 14 LC Base Model

More information

SECTION AIR COOLED WATER CHILLER

SECTION AIR COOLED WATER CHILLER Note: Shading in the body of the specification is to identify work that will be given to the installing contractor in the subsequent Request for Chiller Installation documents to be issued by the Owner.

More information

30GT FLOTRONIC AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS 30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed

More information

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on all models All models utilize round copper tube, aluminum plate

More information

30GN FLOTRONIC II AIR-COOLED CHILLERS

30GN FLOTRONIC II AIR-COOLED CHILLERS 30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM SECTION 23 81 06 - PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. This Section includes equipment types that contain all the components of the refrigeration process within

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

THE FOLLOWING CHANGES/ADDITIONS TO THE ABOVE CITED SOLICITATION ARE ANNOUNCED:

THE FOLLOWING CHANGES/ADDITIONS TO THE ABOVE CITED SOLICITATION ARE ANNOUNCED: Business Services Procurement and Contracting 16550 SW Merlo Road Beaverton, OR 97003 (503) 356-4324 February 20, 2018 SOLICITATION ADDENDUM NO. 2 ITB 18-0003 Kinnaman-Hiteon Chiller Replacement THE FOLLOWING

More information

Wicomico County Purchasing 125 N. Division St. Room B-3 Salisbury, MD Ph Fax Addendum # 1

Wicomico County Purchasing 125 N. Division St. Room B-3 Salisbury, MD Ph Fax Addendum # 1 Addendum No. 1 Wicomico County Purchasing 125 N. Division St. Room B-3 Salisbury, MD 21801 Ph. 410-548-4805 Fax 410-334-3130 Addendum # 1 Date: 3/11/2016 Bid: Chiller Removal and Installation A Pre-Bid

More information

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories. SECTION 238113 - PACKAGED TERMINAL AIR CONDITIONERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units. SECTION 15650 REFRIGERATION PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units. 4. Air

More information

Air-Cooled Stand-Alone ASC Chillers 20 thru 195 Tons

Air-Cooled Stand-Alone ASC Chillers 20 thru 195 Tons Multistack ASC Chillers Air-Cooled Stand-Alone ASC Chillers 20 thru 195 Tons ASC020X, 021X, 025X, 026X, 030X, 031X, 035X, 036X, 00X, 01X, 050X, 060X, 065X, 075X, 080X, 090X, 095X, 100X, 105X, 120X, 135X,

More information

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days Proposal Trane A Division of American Standard Inc. Prepared For: John Weston Desmet Ballestra Job Name: LAUER1 Biodiesel Chiller Pennsylvania Date: August 21, 2006 Proposal Number: G1-95502-1 Engineer:

More information

SECTION CENTRIFUGAL WATER CHILLERS

SECTION CENTRIFUGAL WATER CHILLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Chiller package. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Condenser water connections. F. Variable

More information

Air-Cooled Global Chiller

Air-Cooled Global Chiller Product Manual PM 970 Group: Chiller Effective: June 1997 Supersedes: None Air-Cooled Global Chiller Type AGR 055AS through 100AS Reciprocating Compressor with R-22 60 hertz 1997 McQuay International Table

More information

Liebert CSU3000 Chiller

Liebert CSU3000 Chiller CSI 15620 - Packaged Water Chillers Liebert CSU3000 Chiller Guide Specifications for 7.5-37 Ton CS/CD/CT Models 1.0 GENERAL 1.1 CS/CD MODELS The main-frame coolant supply unit shall be a Liebert Model,

More information

Project Manual. MAHG PROJECT No February 21, architecture planning interiors. Equipment Package

Project Manual. MAHG PROJECT No February 21, architecture planning interiors. Equipment Package Project Manual architecture planning interiors 6400 Riley Park Drive Fort Smith, Arkansas 72916 O: 479.782.1051 F: 479.782.6019 e: info@mahgarch.com MAHG AR CHITE NO. C-93 2.21.2018 ARKAN CTUR AS E REGISTERED

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-42 22 16.00 40 (August 2017) --------------------------------- Preparing Activity: NASA Superseding UFGS-42 22 16.00 40 (August 2014) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Product Data. Features/Benefits. 19XB Positive Pressure Storage System

Product Data. Features/Benefits. 19XB Positive Pressure Storage System Product Data 19XB Positive Pressure Storage System 19XB028 Copyright 1992 Carrier Corporation 19XB052 Carrier s Positive Pressure Storage (PPS) System ensures the critical conservation of refrigerants

More information

Air-Cooled Scroll Compressor Chiller

Air-Cooled Scroll Compressor Chiller Installation, Operation, and Maintenance Manual IOM 1206-1 Air-Cooled Scroll Compressor Chiller Group: Chillers Part Number: IOM1206-1 Date: May, 2014. AGZ030EH - AGZ070EH, Packaged Chillers R-410A, 50/60

More information

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13 Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing

More information

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS SECTION 22 20 00 LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",

More information

Installation Operation Maintenance

Installation Operation Maintenance Installation Operation Maintenance / 015-060 Air-cooled scroll chillers and heat pumps 43-164 kw CG-SVX027B-GB Original instructions Table of Contents General Information...4 Model Number Description...6

More information

Catalog Trailblazer Air-Cooled Scroll Compressor Chillers With High Efficiency Variable Speed Fan Technology

Catalog Trailblazer Air-Cooled Scroll Compressor Chillers With High Efficiency Variable Speed Fan Technology Catalog 624-8 Trailblazer Air-Cooled Scroll Compressor Chillers With High Efficiency Variable Speed Fan Technology Model AGZ-E 030 to 24 Tons (00 to 840 kw) HFC-40A Refrigerant 60/50 Hz Table of Contents

More information

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER PART 1 GENERAL 1.01 RELATED DOCUMENTS A. ANSI Z21.13 American National Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers B. ASME Section

More information

SECTION WATER-SOURCE UNITARY HEAT PUMPS

SECTION WATER-SOURCE UNITARY HEAT PUMPS SECTION 23 81 46 WATER-SOURCE UNITARY HEAT PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SECTION ROTARY SCREW WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

SECTION ROTARY SCREW WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower SECTION 15684 ROTARY SCREW WATER CHILLERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15540 - Pumping Equipment (HVAC) 3. 15711 - Induced Draft Cooling Tower B.

More information

Catalog Trailblazer Air-Cooled Scroll Compressor Chillers With High Efficiency Variable Speed Fan Technology

Catalog Trailblazer Air-Cooled Scroll Compressor Chillers With High Efficiency Variable Speed Fan Technology Catalog 624-5 Trailblazer Air-Cooled Scroll Compressor Chillers With High Efficiency Variable Speed Fan Technology Model AGZ-E 030 to 24 Tons (00 to 840 kw) HFC-40A Refrigerant 60/50 Hz Table of Contents

More information

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R Products That Perform...By People Who Care FORM NO: MS0455A WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R134a HXWC SERIES 205 to 560 Tons 60Hz INTRODUCTION Dunham-Bush's HXWC water cooled

More information

Product Chillers A P P L I C AT I O N S

Product Chillers A P P L I C AT I O N S Product Chillers A P P L I C AT I O N S Wineries Bottling Product Storage Product Ripening Meat Processing Florist Boxes Packaging Rooms Walk-in Coolers Beverage Boxes CENTURY PRODUCT CHILLERS Unit Configuration

More information

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule # Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # Page 1 of 7 Performance Power Compressor 95 F Ambient, Entering Temperature: 54 F, Leaving

More information

Catalog Pathfinder Air Cooled Screw Chillers. Model AWV 165 to 550 Tons (580 to 1935 kw) HFC-134a Refrigerant 60/50 Hz

Catalog Pathfinder Air Cooled Screw Chillers. Model AWV 165 to 550 Tons (580 to 1935 kw) HFC-134a Refrigerant 60/50 Hz Catalog 626-6 Pathfinder Air Cooled Screw Chillers Model AWV 165 to 550 Tons (580 to 1935 kw) HFC-134a Refrigerant 60/50 Hz Table of Contents Table of Contents Introduction.... 3 Features and Benefits...

More information

AIR COOLED PACKAGED CHILLER

AIR COOLED PACKAGED CHILLER AIR COOLED PACKAGED CHILLER UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its

More information

Engineering Manual CCW / CCR. Base Chillers

Engineering Manual CCW / CCR. Base Chillers Engineering Manual CCW / CCR Base Chillers Table of Contents Introduction... 3 Chiller Model Number Nomenclature... 4 Features and Benefits... 5 Unit Description... 7 Unit Controller... 10 Selection Procedure...

More information

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Multi-Institutional Academic Health Science & Research Center Evansville, IN SECTION 236426.11 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

SECTION AIR-SOURCE UNITARY HEAT PUMPS

SECTION AIR-SOURCE UNITARY HEAT PUMPS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 81 43 AIR-SOURCE UNITARY HEAT PUMPS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz Product Data GEMINI SELECT 09DPS018-030,09DPM035-130 Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz 18 to 130 Nominal Tons (63 to 457 Nominal kw) a38-7096 09DPS030 UNIT WITH LOW SOUND OPTION

More information

NEW CHILLER SCHEDULE

NEW CHILLER SCHEDULE TITLE: REPLACE CHILLER MACC MAXIMO # 4542690 PROJECT # 14M108CN MACC # 14-0459 ATTACHMENTS: 1. MAXIMO Equipment update form SCOPE OF WORK: The contractor shall provide all material, labor, equipment, and

More information

Air-Cooled Scroll Compressor Water Chillers

Air-Cooled Scroll Compressor Water Chillers Installation, Operation and Maintenance Manual IOMM AGZ1-2 Group: Chiller Part Number: 331373801 Effective: February 2005 Supersedes: IOMM AGZ1-1 Air-Cooled Scroll Compressor Water Chillers AGZ 010A AGZ

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL 1.1 SUMMARY A. Packaged Chillers offer a self-contained means of producing cooling liquid primarily

More information

SECTION ROTARY SCREW WATER CHILLERS. B. Removal of Existing Refrigerant in Existing Chiller:

SECTION ROTARY SCREW WATER CHILLERS. B. Removal of Existing Refrigerant in Existing Chiller: SECTION 15684 ROTARY SCREW WATER CHILLERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15540 - Pumping Equipment (HVAC). 3. 15711 - Induced Draft Cooling Tower. B.

More information

Catalog Water-Cooled Scroll Compressor Chillers

Catalog Water-Cooled Scroll Compressor Chillers Water-Cooled Scroll Compressor Chillers Model WGZ, D Vintage 30 to 200 Tons (100 to 700 kw) HFC-410A Refrigerant 60/50 Hz Packaged and Condenserless Units Catalog 613-3 Table of Contents Table of Contents

More information

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely

More information

Delta T Systems Variable Speed Chillers Technical Specifications for 1-30 Air Cooled and 2-30 Water Cooled Chillers

Delta T Systems Variable Speed Chillers Technical Specifications for 1-30 Air Cooled and 2-30 Water Cooled Chillers Delta T Systems Variable Speed Chillers Technical Specifications for 1-30 Air Cooled and 2-30 Water Cooled Chillers What Sets Delta T Systems Chillers Apart? Variable Speed Compressor The compressors used

More information

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling

More information

SECTION CENTRIFUGAL WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

SECTION CENTRIFUGAL WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower SECTION 15682 CENTRIFUGAL WATER CHILLERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15540 - Pumping Equipment (HVAC) 3. 15711 - Induced Draft Cooling Tower B. Removal

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

INTRODUCTION TABLE OF CONTENTS NOMENCLATURE AC D S 030 AU G S

INTRODUCTION TABLE OF CONTENTS NOMENCLATURE AC D S 030 AU G S INTRODUCTION For more than 100 years, Dunham-Bush has focused on innovative product development. Today, we provide a full portfolio of HVAC/R products from Fan Coil Units to large centrifugal chillers

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC. WYETH-AYERST CANADA INC. 1025, BOUL. MARCEL-LAURIN S T - L A U R E N T, Q U É B E C INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER MODEL P448800LT--55WC--22C66S Prepared par Claude Gadoury, P.

More information

Catalog Trailblazer Air-Cooled Scroll Compressor Chillers With High Efficiency Variable Speed Fan Technology

Catalog Trailblazer Air-Cooled Scroll Compressor Chillers With High Efficiency Variable Speed Fan Technology Catalog 624-2 Trailblazer Air-Cooled Scroll Compressor Chillers With High Efficiency Variable Speed Fan Technology Model AGZ-E 030 to 240 Tons (00 to 840 kw) HFC-40A Refrigerant 60/50 Hz Table of Contents

More information

Air-Cooled Scroll Compressor Water Chillers

Air-Cooled Scroll Compressor Water Chillers Installation, Operation and Maintenance Manual IOMM AGZ1 Group: Chiller Part Number: 330262001 Effective: October 2001 Supersedes: New Air-Cooled Scroll Compressor Water Chillers AGZ 010A AGZ 034A 10 to

More information