SECTION 8 - SWITCHES AND PROTECTIVE DEVICES TABLE OF CONTENTS
|
|
- Kerry Shields
- 6 years ago
- Views:
Transcription
1 08.00 GENERAL DISTRIBUTION SURGE ARRESTERS CUTOUTS AND ARRESTERS GENERAL CUTOUTS AND ARRESTERS ARRESTERS, 0KV APPLICATION OF DIRECT CONNECTED ARRESTERS ON DISTRIBUTION TRANSFORMERS CUTOUTS AND BRACKETS CUTOUTS AND ARRESTERS OR 3 EACH ON TRIPLE MOUNTING BRACKET 08.0 CUTOUTS AND ARRESTERS SINGLEPHASE TERMINATION ON POLE MOUNTED "L" BRACKET 08.0 CUTOUT AND ARRESTER, () OR (3)PHASE TERMINATION ON TRIPLE MOUNTING BRACKET VERTICAL CONSTRUCTION WITH LIGHTNING ARRESTER DOUBLE CIRCUIT CONSTRUCTION WITH LIGHTNING ARRESTER HORIZONTAL CONSTRUCTION TO HORIZONTAL DEADEND HORIZONTAL CONSTRUCTION TO HORIZONTAL WITH CUTOUT (FLYING TAP) HORIZONTAL CONSTRUCTION TO BRANCH LINE HORIZONTAL CONSTRUCTION WITH LIGHTNING ARRESTER SECTIONALIZERS ELECTRONIC RESETTABLE SECTIONALIZERS RECLOSERS SINGLEPHASE CONFIGURATIONS RECLOSERS, SECTIONALIZERS, TRANSFERS AND THREEPHASE RECLOSER LIGHTNING ARRESTER MOUNTING DETAIL RECLOSER IDENTIFICATION TYPICAL SINGLEPHASE RECLOSER DIMENSIONS, WEIGHTS AND OIL CAPACITIES RECLOSER ASSEMBLY, VERTICAL CONSTRUCTION A OIL CIRCUIT RECLOSER SINGLEPHASE INSTALLATION BYPASS CUTOUT BRACKET B RECLOSER ASSEMBLY, VERTICAL CONSTRUCTION, FEEDER A RECLOSER ASSEMBLY, HORIZONTAL CONSTRUCTION A RECLOSER ASSEMBLY, HORIZONTAL CONSTRUCTION B RECLOSERS THREEPHASE CONFIGURATIONS RECLOSER AND FRAME, THREEPHASE, WITH VERTICAL BYPASS SWITCH A RECLOSER ASSEMBLY, THREEPHASE, WITH VERTICAL BYPASS SWITCH B RECLOSER ON VERTICAL DOUBLE CIRCUIT WITH VERTICAL BYPASS SWITCH RECLOSER ASSEMBLY, THREEPHASE, VERTICAL, 600 AMP SWITCH 08.06A RECLOSER ASSEMBLY, THREEPHASE, VERTICAL, 600 AMP SWITCH 08.06B 3 0 9/8/ CECCONI BURLISON /30/0 CECCONI GUINN REVISED BY CK'D ELKINS ELKINS APPR. SECTION 8 SWITCHES AND PROTECTIVE DEVICES TABLE OF CONTENTS DWG A
2
3
4
5
6
7
8
9
10
11
12
13 6" 8" 8" KHLC40N6F OR KHLC7933F 6" 34" 8" 6" PLAN VIEW PLAN VIEW 8" 34" 6" 8" 8" 6" 6" 4" 4" 36" 6" 7" 7" #6 SD BC NEUTRAL 4" #6 SD BC FRONT VIEW FRONT VIEW NOTES:. CUTOUTS WILL NORMALLY BE INSTALLED ON THE TAP POLE.. SEE SECTION 0 FOR ADDITIONAL GROUNDING DETAILS /3/ BURLISON BURLISON 8//0 ROBESON GUINN REVISED BY CK'D ELKINS ELKINS APPR. HORIZONTAL CONSTRUCTION TO HORIZONTAL DEADEND DWG
14 6" 6" 6" 6" NEUTRAL 4" 6" NEUTRAL PLAN VIEW 36" 6" KHLC40N6F OR KHLC7933F 6" NEUTRAL 4" #6 SD BC FRONT VIEW NOTES:. SEE SECTION 0 FOR ADDITIONAL GROUNDING DETAILS /3/ BURLISON BURLISON 8//0 ROBESON GUINN REVISED BY CK'D ELKINS ELKINS APPR. HORIZONTAL CONSTRUCTION TO HORIZONTAL WITH CUTOUT (FLYING TAP) DWG
15 TANGENT CONSTRUCTION DEADEND TO DEADEND SOURCE NEUTRAL PLAN VIEW LOAD PLAN VIEW KHLC40N6F OR KHLC7933F 6" 36" TOP BOLT OF 'L' BKT GUY ATTACHMENT AND 78" GUY STICK " 7" 4" 7" FRONT VIEW 4" FRONT VIEW 3 0 8/3/ BURLISON BURLISON 8//0 ROBESON GUINN REVISED BY CK'D ELKINS ELKINS APPR. HORIZONTAL CONSTRUCTION TO BRANCH LINE DWG
16
17
18
19
20
21
22
23 5" 4" " 6" 60" 60" 7" 3 0 9/8/ BURLISON BURLISON ELKINS REVISED BY CK'D APPR. RECLOSER ASSEMBLY, VERTICAL CONSTRUCTION, FEEDER DWG A
24
25
26 6" 5" 6 7 4" 48" 4" 5 4 6" 0 48" 35" 9 PT 8 AØ CØ BØ 7" #6 SD BC L TERMINAL L 37" # SD BC L 3 BLACK GREEN GROUND BLACK #6 SD BC SECONDARY ARRESTER SECONDARY ARRESTER CONNECTION 4 HOLE SPADE ON RECLOSER 38" /" SS BOLT LOCKWASHER 48" MIN. #6 BC NUT ROUND WASHER BOLT ON TAMPER GUARD FOR CONTROL CABLE PLUG #6 BC ROUND BOLT 3 0 /7/ 0//0 NOTES:. SWITCHES TO BE ON ROAD SIDE.. PT TO BE LOCATED ON SOURCE SIDE. RELOCATE ON RECLOSER FRAME IF NECESSARY. 3. SIX ARRESTERS REQUIRED: 3 ON EACH SIDE. CONNECT TO TERMINALS OF RECLOSER WITH CONNECTOR UNDER WILDLIFE PROTECTORS. 4. A 45' CLASS 4 POLE IS THE MINIMUM TO BE USED FOR THIS INSTALLATION. 5. TOTAL WEIGHT OF THE RECLOSER AND FRAME IS 850 LBS. 6. ISSUE TAPS TO SWITCHES SEPARATELY (WIRE, CONNECTORS, AND LUGS). BOLTS WILL BE ON SWITCH. 7. ALL BOLTS ON PRIMARY CONNECTIONS ARE TO BE TORQUED TO 40 FTLBS. DO NOT EXCEED! 8. NEUTRAL MAY BE DOUBLE DEADENDED OR STRAIGHT THROUGH ON SPOOL AS NEEDED. 9. SEE DWG B FOR BILL OF MATERIALS. 0. SEE SECTION 0 FOR ADDITIONAL GROUNDING DETAILS. SIMMONS HOFFMAN FRONT VIEW BURLISON GUINN REVISED BY CK'D ELKINS ELKINS APPR. DETAIL "B" RECLOSER AND FRAME, THREEPHASE, WITH VERTICAL BYPASS SWITCH SIDE VIEW DWG A
27 BILL OF MATERIALS MACRO UNIT MACRO UNIT CU ITEM NO CU ITEM NO COMPATIBLE UNIT RCOVR630E5VF RCCNTLPCDABBF RCOVRCAB40F SW56BYPF BKTFBGPIN538F IPIN5PF TTIEF500COVALPF AREQOH0F KLCH50ALF KLCH50AL90DF RCRISER500ALF CRISUGPVC5CF AREQSC0F COMPATIBLE UNIT RCOVR630E7VF RCCNTLPCDABBNSF RCCNTLPCDRFF RCPTREC5C RCPTREC5C RCPCDLCMC QTY REQ'D QTY REQ'D CATALOG NUMBER QTY PER CU ADDITIONAL PARTS FOR REPLACEMENT DESCRIPTION RECLOSER TYPE OVR 630 AMP ELEC. 5KV VRT MNTG W/PT BOLT, MACHINE, SQ, NUT, 5/8" X " WASHER, SQUARE, /4", FLAT, 3/6" HOLE, GALV. WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, ROUND, BELLEVILLE SPRING, FOR /" BOLT WASHER, ROUND, FLAT, STAINLESS STEEL, 304 ALLOY BOLT, MACHINE, STAINLESS STEEL, HEX HEAD, /" X " NUT, STAINLESS STEEL, HEX, 304 ALLOY, COARSE THREAD WIRE, TIE, #4 SD BC, SLD RECLOSER CONTROL PCD 000 FOR ABB RECL RECLOSER CONTROL CABLE FOR ABB VR3 AND OVR, 40FT WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, SQUARE, /4", FLAT, 3/6" HOLE, GALV. BOLT, MACHINE, SQ, NUT, 5/8" X " SWITCH, BYPASS, 3SLD BLADE DISCONNECT, 5KV, LBK BRACKET, FIBERGLASS STANDOFF, 3/8" THREAD INSULATOR, 5 KV POLYMER, 3/8" THREAD PLASTIC TIE WRAP FOR 7/8" FNECK INSULATOR ARRESTER, LIGHTNING, 0KV HD MOV W/SILICONE RUBBER POLY BOLT, MACHINE, STAINLESS STEEL, HEX HEAD, /" X " NUT, STAINLESS STEEL, HEX, 304 ALLOY, COARSE THREAD WASHER, FLAT, ROUND, SILICON, BRONZE, FOR /" BOLT LUG, COMP H 500 AL WASHER, ROUND, RD, /, SS,.375" OD LUG, HOLE, TINPLATED, NEMA, 90 DEGREE CABLE, XLP UG AL 500 GUARD, PVC, CABLE, /4" X 0' BANDING, STAINLESS STEEL, 36, 3/4" WIDE,.030 TH BANDING, BUCKLE, SS, 3/4", FOR BANDING ARRESTER, LIGHTNING, SEC WIRE GUARD, ANIMAL, TERMINAL GUARD, STRAIGHT GUARD, ANIMAL, LSHAPED, GUARD GUARD, ANIMAL, PT OR VOLTAGE TRANSFORMER QTY CATALOG PER NUMBER CU DESCRIPTION RECLOSER, ABB OVR630 AMP, KA, 7KVHV EDGEMOUNT COASTAL RECLOSER, PCD,CONTROL,LV,MODULE,WITHOUT,SINGLEPHASE,TRI RECLOSER, CONTROL, PCD 000 COOPER RETROFIT TRANSFORMER, POTENTIAL, 5KV,700V TRANSFORMER, POTENTIAL, 5KV,4400V OUTDOOR TRANSFORMER MODULE, LOOP CONTROL, RECLOSER, ABB, FOR PCD CONTROL CABLE LOCKING SLEEVE ABB RECL. CTRL CABLE CONNECTOR BATTERY, RECLOSER, PCD CNTRL, 48VDC (SET OF 4VDC) CABLEPT, ABB RECLOSER, 8 FOOT, W/5PRONG CONNECTORS ABB PCD SINGLEPHASE TRIP CARD COM5 MODULE/CARD FOR ABB PCD CONTROL (SLOTE) ABB PCD UPS CARD TYPE 3, 48VDC (SLOTA) ABB PCD UPS CARD TYPE, 48VDC (SLOTA) ABB PCD DIOB I/O CARD (SLOTB) ABB PCD DIO I/O CARD (SLOTC) ABB PCE CPU CARD (SLOTD) ABB PCD COMA CARD (SLOTE) ABB PCD PT/CT 600: CARD (SLOTF) EXTERNAL PT FOR ABB OVR RECL, 3.8V, 0BIL, VOG, 60: COASTAL EXT. PT ABB OVR RECL, 3.8 KV, 5 KV BIL, W/60: RATIO NOTES:. GROUND RESISTANCE TO BE 5 OHMS OR LESS.. A 45' CLASS 4 POLE IS THE MINIMUM TO BE USED FOR THIS INSTALLATION. 3. TOTAL WEIGHT OF RECLOSER ASSEMBLY IS 850 LBS. 4. ISSUE TAPS TO SWITCHES SEPARATELY (WIRE, CONNECTORS, AND LUGS). BOLTS WILL BE ON SWITCH. 5. ALL BOLTS ON PRIMARY CONNECTIONS ARE TO BE TORQUED TO 40 FTLBS: 6. SEE DWG A DESIGN SPECIFICATIONS. 3 0 /7/ HOFFMAN BURLISON /9/0 HOFFMAN GUINN REVISED BY CK'D ELKINS ELKINS APPR. RECLOSER ASSEMBLY, THREEPHASE WITH VERTICAL BYPASS SWITCH DWG B
28
29
30
31 PROGRESS ENERGY STANDARD PROCEDURE PURPOSE: TO ENSURE PROPER OPERATION OF ALL DISCONNECT SWITCHES, ALL SWITCHES MUST BE PERIODICALLY OPERATED, INSPECTED, ADJUSTED, AND MAINTAINED. THE FOLLOWING INSPECTION, OPERATION, MAINTENANCE AND ADJUSTMENT PROCEDURES SHOULD BE PERFORMED ON ALL DISCONNECT SWITCHES AT LEAST EVERY FIVE (5) YEARS. MAINTENANCE PROCEDURES: INSPECTION: VISUALLY INSPECT THE SWITCH TO DETERMINE IF ANY DAMAGE THAT WOULD PREVENT THE SWITCH'S SAFE OPERATION HAS OCCURRED TO THE SWITCH PRIOR TO OPERATING. OPERATION: ISOLATE THE SWITCH SO THAT IT CAN BE OPERATED MECHANICALLY USING THE APPROPRIATE PROCEDURE: A. NORMALLY OPEN SWITCH. CONTACT GRID MANAGEMENT TO DETERMINE IF FEEDERS OR SUBSTATIONS CAN BE TIED TOGETHER SO SWITCH CAN BE OPERATED WITHOUT DISCONNECTING JUMPERS.. IF FEEDERS OR SUBSTATIONS CAN NOT BE TIED, DISCONNECT THE JUMPERS AND TIE THEM BACK SECURELY OUT OF THE WAY. B. NORMALLY CLOSED INSTALL MECHANICAL BYPASS JUMPERS SO THAT THE SYSTEM WILL NOT BE DISTURBED BY THE SWITCHING OPERATION.. OPERATE SWITCH SEVERAL TIMES TO DETERMINE IF THE MECHANISM IS OPERATING FREELY AND ALL ENERGIZED PARTS ARE IN PROPER ALIGNMENT. THE BLADE MUST FULLY CLOSE INTO THE JAW CONTACTS.. WITH SWITCH IN CLOSED POSITION, CHECK TO ENSURE THE BLADE IS FULLY CLOSED AND MAKES PROPER CONTACT. 3. ANY DEFECTIVE SWITCH WHICH CANNOT BE IMMEDIATELY REPAIRED, SHOULD BE TAGGED AT THE SWITCH TO WARN AGAINST OPERATING. THE DISTRIBUTION CONTROL CENTER SHALL ALSO BE NOTIFIED. 4. CHECK FOR CRACKED OR BROKEN INSULATORS AND DAMAGE TO "ENERGIZED PARTS". 5. CORRECT ANY MINOR DISCREPANCIES OR DAMAGED PARTS. 6. CHECK THE HINGE TO MAKE SURE IT CAN ROTATE EASILY, BUT WITH SOME RESISTANCE DUE TO CONTACT PRESSURE. IF NECESSARY, SAFELY LUBRICATE THE HINGE WITH A PENETRATING SPRAY TYPE LUBRICANT (NONFLAMMABLE IF AVAILABLE). 7. WIPE CLEAN BOTH CONTACTS AND REAPPLY A SMALL AMOUNT OF LITHIUMBASED GREASE. DO NOT USE A FIBERBASED LUBRICANT SUCH AS WHEEL BEARING GREASE. PEC REPLACEMENT PARTS NAME COMPATIBLE UNIT CATALOG NUMBER S&C INTERRUPTER SWOPINTRMODSCC BRIDGES INTERRUPTER SWOPINTRMODBRC 765 BRIDGES INSULATOR SWOISP3BRC NOTES:. NEVER USE A "NOOXIDE" GREASE OR AN INHIBITORBASED ELECTRICAL JOINT COMPOUND DESIGNED FOR SOLID BOLTED CONNECTIONS ON EITHER THE HINGE OR JAW CONTACTS. IF USED, AN INHIBITOR WILL EVENTUALLY "LOCKUP" THESE MOVING CONTACTS. 3 0 /9/ COX BURLISON 7//0 GUINN GUINN REVISED BY CK'D ELKINS ELKINS APPR. DISCONNECT SWITCH INSPECTION, OPERATION AND MAINTENANCE (O&M) DWG
32
33
34 BILL OF MATERIALS MACRO UNIT CU ITEM NO. COMPATIBLE UNIT QTY REQ'D CATALOG NUMBER QTY PER CU DESCRIPTION 4 SW56SBDF BKTLASWBKTSTLF 3 BKTSBDSWSTLF AREQOH0F BKTCOLASNGSTLF KHLC7933F BOLT, MACHINE, STAINLESS, STEEL, HEX, HEAD, /" X " NUT, STAINLESS, STEEL, HEX, 304, ALLOY, COARSE, THREAD WASHER, ROUND, BELLEVILLE, SPRING, FOR, /", BOLT WASHER, ROUND, FLAT, /", BOLT WASHER, SPRING, COIL, STEEL, FOR 5/8", BOLT, GALV. WASHER, /4", SQUARE, FLAT, 3/6", HOLE, GALV. BOLT, MACH, SQ, NUT, 5/8" X " CONNECTOR, COMP, DBL, TABS, CU, 66 CONNECTOR, COMP, AL, A=/0STRSOL, B=STR6SOL WIRE, CU, BR, SDW, 7, STR, # WIRE, CU, BR, SDW, SLD, #6 WASHER, RD, /, SS,.375" OD BOLT, MACHINE, STAINLESS, STEEL, HEX, HEAD, /" X " NUT, STAINLESS, STEEL, HEX, 304, ALLOY, COARSE, THREAD BRACKET, MNTG SWITCH ARSTR WASHER, RD, /, SS,.375" OD WASHER, SPRING, COIL, STEEL, 5/8", BOLT, GALV WASHER, SQUARE, /4", SQUARE, FLAT, 3/6 BRACKET, MNTG WD/CNCR POLE BOLT, MACH, SQ, NUT, 5/8" X " ARRESTER, LIGHTNING, 0KV HD MOV W/SILICONE RUBBER P CABLE, 600V, #6 SD BC WASHER, SPRING, COIL, STEEL, FOR 5/8", BOLT, GALV. WASHER, /4", SQUARE, FLAT, 3/6", HOLE, GALV. BOLT, MACH, SQ, NUT, 5/8" X 0" BRACKET, SGL MT CONNECTOR, HOT LINE CLAMP, 795 MCM TO 336 MCM NOTES:. SEE DWG. 08.0A FOR DESIGN SPECIFICATIONS. 3 0 /5/ HOFFMAN BURLISON ELKINS /9/0 HOFFMAN GUINN ELKINS REVISED BY CK'D APPR. SWITCH MOUNTING IN VERTICAL DOUBLE CIRCUIT DWG. 08.0B
35
36
37 5" LOAD LINE " TYP. 36" " 7" #6 SD BC NEUTRAL #6 SD BC SIDE VIEW FRONT VIEW MACRO UNIT SA3SV BILL OF MATERIALS CU QTY COMPATIBLE QTY CATALOG ITEM PER UNIT REQ'D NUMBER NO. CU DESCRIPTION SW53COSBDF KV CUTOUT WITH 300A SOLID DOOR SW53COSBDF KV CUTOUT WITH 300A SOLID DOOR 0098 BOLT, MACHINE, STAINLESS STEEL, HEX HEAD, /" X " BKTLASWBKTSTLF NUT, STAINLESS STEEL, HEX, 304 ALLOY, COARSE, THREAD, /" BRACKET, MNTG SWITCH ARRESTER BRACKET WASHER, RD, /, SS,.375" OD 0364 WASHER, SPRING, COIL, STEEL, FOR 5/8", BOLT, GALV. 3 BKTCOLASNGSTLF WASHER, SQUARE, /4", FLAT, 3/6" HOLE, GALV. 506 BOLT, MACHINE, 5/8" X 0", STEEL, AASTM A307, GALV 363 BRACKET, SINGLE MOUNT 4 AREQOH0F 6 00 ARRESTER, LIGHTNING, 0KV HD MOV W/SILICONE RUBBER POLY 5 KHLC40N6F CLAMP, HOT LINE, ALUM, SMALL, 4/0 KHLC7933F CLAMP, HOT LINE, ALUM, LARGE, NOTES:. 300 AMP DISCONNECT IS AVAILABLE 5KV AND 5KV (COASTAL AND HOLOPAW) /3/ BURLISON BURLISON 6/6/ HOFFMAN BURLISON 8/3/0 GUINN GUINN REVISED BY CK'D ELKINS ELKINS ELKINS APPR. SWITCH ASSEMBLY, 300 AMP, SOLID BLADE, VERTICAL DWG
38
39 MACRO UNIT CU ITEM NO. COMPATIBLE UNIT SW56SBDF BKTLASWBKTSTLF QTY REQ'D 3 BKTSBDSWSTLF 3 4 AREQOH0F 6 5 KHLC7933F BILL OF MATERIALS CATALOG NUMBER QTY PER CU DESCRIPTION BOLT, MACHINE, STAINLESS, STEEL, HEX, HEAD, /"X" NUT, HEX, / IN, A304, STAINLESS STEEL WASHER, ROUND, BELLEVILLE SPRING, FOR /" BOLT WASHER, ROUND, FLAT, STAINLESS STEEL, 304, ALLOY, FOR,/" BOLT, MACH, HEX, HD, /"X" SWITCH, DISCONNECT, SOLID BLADE, 5KV, 600A, PH, SWITCH BOLT, MACHINE, STAINLESS, STEEL, HEX, HEAD, /" X " NUT, STAINLESS, STEEL, HEX, 304, ALLOY, COARSE, THREAD BRACKET, MNTG SWITCH ARSTR WASHER, RD, /, SS,.375" OD WASHER, SPRING, COIL, STEEL, 5/8", BOLT, GALV WASHER, SQUARE, /4", SQUARE, FLAT, 3/6 BRACKET, MNTG WD/CNCR POLE BOLT, MACH, SQ, NUT, 5/8" X " ARRESTER, LIGHTNING, 0KV HD MOV W/SILICONE RUBBER P CONNECTOR, HOT LINE CLAMP, 795 MCM TO 336 MCM DETAIL SWITCH BRACKET NOTES:. SEE DWG A FOR DESIGN SPECIFICATIONS. 3 0 /6/ HOFFMAN BURLISON ELKINS 4/5/ /9/0 HOFFMAN HOFFMAN BURLISON GUINN REVISED BY CK'D ELKINS ELKINS APPR. SWITCH ASSEMBLY, 600 AMP, SOLID BLADE, VERTICAL DWG B
40 PLAN VIEW 6" TYP. 6" KHLC40N6F OR KHLC7933F 4" 6" 60" FRONT VIEW SIDE VIEW NOTES:. IN LOCATIONS WHERE THE SWITCH COULD BE USED TO TRANSFER LOAD AND COULD BE LEFT IN THE OPEN POSITION FOR AN EXTENDED PERIOD OF TIME, ENGINEERING SHOULD CALL FOR LIGHTNING ARRESTERS ON BOTH SIDES OF THE SWITCH /3/ BURLISON BURLISON /5/0 HOFFMAN GUINN REVISED BY CK'D ELKINS ELKINS APPR. SWITCH ASSEMBLY, 300 AMP, SOLID BLADE HORIZONTAL DWG
41
42 5" 4" PLATED TERMINAL PADS 7" 4" DEADENDING HOLE 3/8" /6" DIA. PULLOFFHOLE 53/6" LOADBREAK HOOK MACRO UNIT CU ITEM NO. COMPATIBLE UNIT QTY REQ'D BILL OF MATERIALS CATALOG NUMBER SW56ILSBDF QTY PER CU DESCRIPTION WASHER, ROUND, BELLEVILLE SPRING, FOR /" BOLT SWITCH,.., DISCONNECT TEMP DECLMP(WIRE)F DEADEND CLAMP 3 IDES5PF NOTES:. SEE DWG A FOR THE PREFERRED 600 AMP SWITCH INSTALLATION. INLINE SWITCHES MAY BE USED TO FACILITATE CONSTRUCTION, RESTORATION OR REPAIR. WHEN USED FOR THESE PURPOSES, THEY SHOULD BE REMOVED AT THE COMPLETION OF WORK. INLINE SWITCHES MAY BE USED FOR A PERMANENT INSTALLATION WHEN THE PREFERRED INSTALLATION IS IMPRACTICAL OR IMPOSSIBLE. 3 0 // ROBESON BURLISON ELKINS /5/0 HOFFMAN GUINN ELKINS REVISED BY CK'D APPR. 600 AMP INLINE DISCONNECT DWG
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
SWITCHING SWITCHING. Overhead Electric Distribution Standards INTRODUCTION
INTRODUCTION 1. All group-operated switches installed shall be load-break. The interrupters are now included with the plates and no longer need to be itemized as in the past. The identification plates
More informationSINGLE-PHASE STANDARD
INTRODUCTION 1. The Single-Phase Standard was developed to lower JEA s costs by allowing primary construction on a 40-foot wood pole. However, there are limitations to the use of this standard when installed
More informationCATALOG OF REPLACEMENT PARTS Q SERIES OVER/UNDER REFRIGERATION SYSTEM. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO
CATALOG OF REPLACEMENT PARTS Q SERIES OVER/UNDER REFRIGERATION SYSTEM A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 43021 (August 2001) 1-2-3 51 50 52 20 21 17-18-19 48-49
More informationHT650 TM FAN DRIVE SERVICE INSTRUCTIONS
HT650 TM FAN DRIVE SERVICE INSTRUCTIONS When unpacking your product, remove all components and inspect them to ensure that no damage occurred during shipping. If any components are missing or damaged,
More informationService part catalogue
Service part catalogue SelfCookingCenter whitefficiency CD-Ges_101207 2011 Rational Technical Service All Rights reserved SelfCookingCenter whitefficiency 2 SelfCookingCenter whitefficiency Pos. Part No.
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL TUBE AXIAL FANS BTA, WTA, HTA, DDA The purpose of this manual is to aid in the proper installation and operation of the fans. These instructions are intended
More informationMK-1605 Electric Concrete Saw EXPLODED VIEW & PARTS LIST
www.mkdiamond.com MK-0 Electric Concrete Saw EXPLODED VIEW & PARTS LIST MK-0B Premium Part# 8099 Revision 0 0.08 Manual Part# 79 Caution: Read all safety and operating instructions before using this equipment.
More informationAn ibuy Stores Company
REVISED STARTING SERIAL NO. 060604 PARTS MANUAL Model SK-4 4 DOWNCUT CONCRETE/ASPHALT WALK BEHIND SAWS SKU NO. MODEL POWER OPTION 45400D SK4-9H HONDA ENGINE 9 HP GX0 45600D SK4-H HONDA ENGINE HP GX40 4800D
More informationFES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS
FOSTORIA INDUSTRIES, INC. A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible.
More informationHustler Z Bac Vac Parts Manual ,
Hustler Z Bac Vac Parts Manual 967, 988 Hustler Turf Equipment P.O. Box 7000 Hesston, Kansas 6706-097 t- 56 06/08 Table of Contents Chapter General Information.................................... - Chapter
More informationWATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2
I&M NUMBER: 316-42-15-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to
More informationINSTRUCTION MANUAL with Replacement Parts
INSTRUCTION MANUAL with Replacement Parts MODEL FD500 FOOD WASTE DISPOSERS (INCLUDES MOTOR PARTS) ML-18978 A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 11394 Rev. G (10-98)
More informationInstallation Instructions Part No , Part No Part No
Torsion-Flex Motor mount for PSC motors and Rigid-Mount for ECM motors Replacement Kit Cancels: New Installation Instructions Part No. 327752-401, Part No. 327753-401 Part No. 327754-401 IIK-310A-45-11
More informationINSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D.
A-11978 HEATER KIT Figure 1 (General Layout and Parts I.D.) Read these instructions and identify all components. Please retain these instructions for future reference and parts ordering information. Refer
More informationTechnical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.
Technical Manual VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater Provided by: Chart Inc. 407 7th Street NW New Prague, MN 56071 USA (800) 400-4683 Part Number 20977233 Rev. A 2016 Chart Inc.
More informationEffective May 2017 Supersedes October 1998 (S )
Padmounted Switchgear MN285017EN Effective May 2017 Supersedes October 1998 (S285-75-3) COOPER POWER Type VFI Tri-Phase ground control retrofit instructions and internal CT polarity test procedures SERIES
More informationSpare Parts List (Kits) Model Ref.:- HM35 SERIES A Spare Parts List (Kits) Issue 8 Dated 10-February-2015 Reference Drawing 09-1108-0000 Issue B Dated 07-January 2014 Drawing Ref. Part Number DESCRIPTION
More informationASTRO ENVELOPE FEEDER AMC FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS
ASTRO ENVELOPE FEEDER AMC-2000-17 FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION Thank you for purchasing the Astro Envelope Feeder. It is fast, efficient, reliable, and
More informationWATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00
I&M NUMBER: 316-42-16-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS LXGe SERIES GLASSWASHERS ML-130255 ML-130256 ML-130257 ML-130258 LXGePR (Cold) LXGeR (Hot) A product of HOBART 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 43304 Rev. A (May
More informationHeat Exchanger Block Replacement Instructions
Series 1-4 Gas-fired water boiler Heat Exchanger Block Replacement Instructions Ultra-80 S1-4 Heat Exchanger Block Replacement Kit, Part No. 383-500-773 Ultra-105 S1-4 Heat Exchanger Block Replacement
More informationA B A B4
TM TM SERVICE INSTRUCTIONS Thermo-Aire Heater Kits and Air-Heater Assemblies 383808-A4 383808-B4 383880-A4 383880-B4 DESCRIPTION The Thermo-Aire Heater is used in situations where oils of heavier viscosity
More informationInstallation Instructions
50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions
More informationIMPORTANT SAFETY INFORMATION
OPERATION INSTALLATION PARTS MANUAL www.fostoriaindustries.com Made in U.S.A. ELECTRIC PORTABLE HEATER FES-1024-1CA 08860010 YES-1024-1CA 08861510 FES-1520-3A 08860110 YES-1520-3A 08860810 FES-1524-1A
More informationUSER S MANUAL EUROPEAN SCRUB-PRO GOLF BALL CLEANSER
USER S MANUAL EUROPEAN SCRUB-PRO GOLF BALL CLEANSER Magnum Scrub-Pro Golf Ball Cleanser is made with a durable polyethylene body and a tubular steel powder coated frame. Features include scattered trim
More informationMK-100 JCS Tile Saw TILE SAW OWNER S MANUAL & OPERATING INSTRUCTIONS SERIAL NUMBER:
MK-00 JCS Tile Saw TILE SAW OWNER S MANUAL & OPERATING INSTRUCTIONS CAUTION: Read all safety and operating instructions before using this equipment Enter the Serial Number of your new saw in the space
More informationInstallation Instructions
GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover
More informationmodel NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS
000 model NO. LSS- 00 GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS Part number and descriptions can be obtained from the illustrated parts list section of this manual.
More informationCATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO
CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN HSROG ML-111148 A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 43003 (June 2001) HOT SECTION 26 OVEN TOP SECTION
More informationSCC 61 E Valid as of E61SE0404 up to E61SE... SCC 61 E
Electrical unit Voltage 3NAC 400V 50-60Hz 1 1 Control panel 2 2 Electrical installation 3 3 Clima Plus 4 4 Steam generator, Bypass 5 5 Hot air heating 6 6 Motor and fan wheel 7 7 Interior cabinet 8 8 Door
More informationModel: FT110 Dishwasher
PARTS MANUAL HOBART FOOD EQUIPMENT CO., LTD Model: FT110 Dishwasher HOBART FOOD EQUIPMENT CO., LTD 2003-07-10 Table of Contents Page Description 2 Panels, Upper chamber and Tank 4 Control Box 6 Control
More informationMarley Ultra Quiet Fan
USER MANUAL Marley Ultra Quiet Fan DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS M2012-1165 ISSUED 8/2012 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. safety and
More informationTesting Accessories. Test PaddleS. Test Paddle Attachment Plugs Insulated Socket Wrench Jumper Strips Test Lead Kit
Testing Accessories Test Paddles Test Paddle Attachment Plugs Insulated Socket Wrench Jumper Strips Test Lead Kit Test PaddleS The 10 and 14 pole potential test paddles are feature packed and have been
More informationBoltek EFM-INV-M / EFM-INV2 / EFM-INV3 Inverting Mounting Kit. Installation Instructions
Boltek EFM-INV-M / EFM-INV2 / EFM-INV3 Inverting Mounting Kit Installation Instructions Introduction The EFM-INV-M, EFM-INV2, and EFM-INV3 Inverted Mounting Kits will allow you to mount your EFM-100 or
More informationService Parts Manual Integrated (700-(
Service Parts Manual Integrated (700-( 700BF/I- DRAWER VIEW PARTS LIST Ref # Part # Description 0000 Screw, #-5 x /" Truss HD 00 Tube Clamp, Steel, 3/" 3 000 Channel, Wire 7.5" 0070 Screw, #- x / PH Truss
More informationCMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.
CMA Dishmachines 1700 Knott Avenue Garden Grove, CA 981 Toll Free: 1- (800) 8-617 Fax: 1- (71) 89-11 Service Replacement Parts Undercounter High Temperature Dishwasher Model: UC6e M Machine Serial No.
More informationWarning Do not attempt to install A/C units unless you are experienced with servicing A/C systems! Wire Cutter / Crimper Socket set
INSTALLATION INSTRUCTIONS PT-A-405 Rear HVAC System for 2014-2018 RAM PROMASTER with OEM rear AC/Heat Prep Package Fittings For Installation with Havis Prisoner Transport Insert Warning Do not attempt
More informationSCC 101 G Valid as of G11SE0404 up to G11SE... SCC 101 G
Gas unit Voltage 1NAC 230V 50-60Hz 1 1 Control panel 2 2 Electrical installation 3 3 Clima Plus 4 4 Steam generator, Bypass 5 5 Hot air heating 6 6 Motor and fan wheel 7 7 Interior cabinet 8 8 Door 9 9
More informationSTAND ALONE DRYER BASE. Parts Manual
STAND ALONE DRYER BASE Parts Manual TABLE OF CONTENTS DRYER BASE SYSTEM DRYER BASE SYSTEM ASSEMBLY (FIG. 1) 3 FRAME ASSEMBLY (FIG. 2). 5 CONVEYOR DRIVE ASSEMBLY (FIG. 3)...7 IDLER SHAFT / TENSIONER ASSEMBLY
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS STEAM BOOSTER FOR DISHWASHERS #150-1 ML-110451 #180-1 ML-18599 #260 ML-18600 (0 to 20 PSI) ML-31683 (21 to 50 PSI) #320 ML-18601 (0 to 20 PSI) ML-31684 (21 to 50 PSI) #380
More informationALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL
ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL EFFECTIVE MAY, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified are
More informationHoshizaki America, Inc.
Hoshizaki America, Inc. Commercial Series Refrigerated Kitchen Equipment Models CRA-FS CRA-HS CFA-FS CFA-HS A Superior Degree of Reliability PARTS LIST www.hoshizaki.com Number: 71309 Issued: 7-1-011 CONTENTS
More informationSCC 201E Valid as of E21SE0404 up to E21SE... SCC 201E
Electrical unit Voltage 3 NAC 400V 50-60Hz 1 1 Control panel 2 2 Electrical installation 3 3 Clima Plus 4 4 Steam generator, Bypass 5 5 Hot air heating 6 6 Motor and fan wheel 7 7 Interior cabinet 8 8
More informationParts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com
Parts List Stackable Crescent Cuber Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3 hoshizakiamerica.com Number: 71384 Issued: 8-31-2017 Revised: 3-26-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering
More informationGP-6 Cabmaker Owner s Manual and Operating Instructions
GP- Cabmaker Owner s Manual and Operating Instructions Belts Model: Part# 80008 Diamond Pads Model: Part# 80005 Carbide Wheel Model: Part# 8000 Revision 05 0.08 Manual Part No. 597 Caution: Read all safety
More informationInstallation and Maintenance Manual Please retain this manual for future reference.
342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. Electric Construction Heaters
More informationParts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-901MAJ KM-901MWJ KM-901MRJ/3 hoshizakiamerica.com Number: 71391 Issued: 10-23-2017 Revised: 6-8-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...
More informationVFA6-HD TOLERANCE NOTES CEK 1/25/2017 VFA6-HD CUSTOMER BMC 12/13/2017 6' HEAVY DUTY V-FRAME ASSEMBLY WITH TWO STIFF ARMS 1 OF 5 PARTS LIST
ITEM 6 7 9 0 6 7 9 0 6 7 9 6 QTY 70 7 6 X-VFAW X-HDCAMTBW X-MHTPHD X-VFAPL X-LCBP X-HDCAMSS X-SPTB X-HDCAMSP X-TBCA SC MCP DCP P P6 A GFW GLW GNUT GR- GR- GR- X-UB0 X-UB G07 G06 G0 A G0 GFW GLW GNUT X-UB0
More informationSection 8: Switchgear Connections (Straight & Elbows)
8: Switchgear Connections (Straight & Elbows) HEAT SHRINKABLE RSRB Inline and Right Angle Bushing Boots 126 PUSH ON ELBOWS RCAB-41 Elastomeric Flexible Bushing Boot - up to 17.5kV 127 RCAB-51 Inline Cold
More informationLuxury Bathing & Entertainment System PARTS CATALOG MODEL #M MODEL #M ISSUE DATE: 10/98 CATALOG #M868000B
TM Luxury Bathing & Entertainment System PARTS CATALOG CATALOG #M000B TABLE OF CONTENTS J-Allure Reference Enclosure Assembly Fastener Indentification Guide Center Panel Components Center Panel Components
More informationHeat Exchanger Tube Change Procedure
Heat Exchanger Tube Change Procedure Application: DATS II, DATS III, CorrDATS, CFM-500 and high temp, 120 or 240 VAC manufactured after 1 May 01 Last Update: 17 Dec 02 The DATS II and III systems use identical
More informationWASHER/DRYER CONTROL PANEL PARTS
WASHER/DRYER CONTROL PANEL PARTS WASHER/DRYER LAUNDRY SYSTEM 1 Literature Parts W10356098 Installation Instructions W10343071 Guide, Use & Care W10364010 Wiring Diagram W10343084 Energy Guide 2 3390688
More informationEX20. Parts List Models: (100C) (cold), (100H) (heated), (100SC) (single cord, heated) Form No /2015 REV A
EX0 Parts List Models: 560588 (00C) (cold), 560589 (00H) (heated), 560590 (00SC) (single cord, heated) Form No. 56065 5/05 REV A GENERAL VIEW Item Ref. No. Qty Description Base System Recovery System Solution
More informationTSC & TSC-M Proofer/Oven
Illustrated Parts List BAKING CENTER BAKING CENTER TSC & TSC-M Proofer/Oven MODELS: TSC-6/8 TSC-6/8M TSC-/9 (Introduced February/009) TSC-/9M (Introduced January/0) This manual is Copyright 07 Duke Manufacturing
More informationMANUAL RESET ALARM RELEASE
Fire Door Release MODEL AR-D MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual
More informationMANUAL RESET ALARM RELEASE
Fire Door Release MODEL AR-D2 MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D2 GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual
More informationService Parts Manual Integrated (700-3 BASE) Series
Service Parts Manual 2 27 3 2 23 1 30 1 20 2 22 1 31 1 17 2 25 7 1 2 1 5 Integrated (700-3 BASE) Series SUB-ZERO FREEZER COMPANY INC. 2005 ALL RIGHTS RESERVED JOB AID #37525 (Revision B - December, 2005)
More informationB. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).
Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage
More informationFRL 10 Centrifugal blowers
FRL 10 Centrifugal blowers User instructions 2 Kongskilde Blower model FRL10. Motor mounting instructions Motor Specifications: Model FRL 10 Blower/Aspirator fans are designed to be driven by Single or
More informationSolid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES
Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES PRODUCT DATA FEATURES Solid and Split Core, Fixed Current go/no go switches. Very low operating trip points. LED
More informationCARRIER MIRACOOL SERVICE PARTS LIST MC260 AND MC300 ALL MODELS
CARRIER MIRACOOL SERVICE PARTS LIST MC260 AND MC300 ALL MODELS 260L/300L SALES OFFICE: P.O. BOX 5932 SPARTANBURG, S.C. 29304-5932 PHONE: (864) 582-8 TOLL FREE -800-845-9800 TECHNICAL SERVICE: -800-684-99,
More informationService Manual. Ice Dispensing Bin Models DB-130H. hoshizakiamerica.com
Service Manual Ice Dispensing Bin Models DB-130H hoshizakiamerica.com Number: 73128 Issued: 5-6-2014 Revised: 2-19-2018 IMPORTANT Only qualified service technicians should attempt to service or maintain
More informationOwner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service
Owner's Manual (00 Gallon Lawn Service Skid Sprayer) Technical Specifications. Horsepower Recoil Start Engine Roller Cast Iron Pump 0 Gallons Per Minute at 0 PSI Pressure Gauge-Adjustable Pressure Range
More informationService part catalogue SelfCooking Center 102 validity: 10/2008
Service part catalogue SelfCooking Center 102 Overview 2 Overview Pos. Module Page 010.000 Control panel........................................................................................ 4 020.000
More informationService Manual. Ice Dispensing Bin Models DB-200H. hoshizakiamerica.com
Service Manual Ice Dispensing Bin Models DB-200H hoshizakiamerica.com Number: 73136 Issued: 5-8-2006 Revised: 2-19-2018 IMPORTANT Only qualified service technicians should attempt to service or maintain
More informationRevised 9/05. Model X-750 Subassembly Parts List
Revised /0 Model Subassembly Parts List Blade Belt Tensioner 0 PART NUMBER DESCRIPTION QTY. -G0-0-0 SHSB, / x / -G0-0-0 SHSB, / x / -X-0-00 Arm, Belt Tensioner -G0-0-00 Washer, Flat /" -0-0-0 Washer, Split
More informationPowers TM Controls Accessories for Installing TH 192, TH 194 or Free Energy Band TH 193 HC Room Thermostats
Powers TM Controls Accessories for Installing TH 192, TH 194 or Free Energy Band TH 193 HC Room Thermostats Technical Bulletin Document No. 155-244P25 TB 237 Rev. 2, December, 2001 Purpose This technical
More informationInstalling the Cisco ONS FAP-4 Fuse Alarm Panel
Installing the Cisco ONS 15454-FAP-4 Fuse Alarm Panel Product Number: 15454-FAP-4= This document explains how to install, test, operate, and maintain the Cisco ONS 15454-FAP-4 fuse alarm panel. This document
More informationNoran Tel. FUSE PANEL Technical Practice N NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified
0232-03J December 13, 2006 FUSE PANEL Technical Practice N215112-NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 2 KLM and 4 GMT fuses in each (30Amps/KLM, 15Amps/GMT).
More informationPARTS MANUAL. American Dish Service MODEL: 5-AG-S ADS LOW TEMPERATURE DISHWASHER EFFECTIVE: JULY, 2013 C 4/08
EFFECTIVE: JULY, 2013 ADS LOW TEMPERATURE DISHWASHER MODEL: PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 C 4/08 The American Dish Service part numbers contained in this publication
More informationSlow drying Thermostat What is temperature set at on control. Check for adequate makeup air (1.5 sq. Ft.)
Tumbler turns ignition sparks no flame Gas supplymake sure gas supplyis working Gas pressure Make manometer check of gas pressure for 3.5" W.C. or more at supply side Spark electrode Gas valve Check electrode
More informationD. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationReliable solutions for electrified railway systems
Reliable solutions for electrified railway systems 1 2 3 Insulation Enhancement System Insulation Enhancement System 1. Raychem MVLC: (Medium Voltage Line Cover) Provides insulation for catenary, droppers
More informationService Manual Trash Compactor Models 15XESSEXF A November 2010 Broan-NuTone LLC 926 West State Street Hartford, WI
Service Manual Trash Compactor Models 15XESSEXF 99044663A November 2010 Broan-NuTone LLC 926 West State Street Hartford, WI 53027 1-800-637-1453 2 Safe Servicing Practices Safe Servicing Practices To avoid
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS CU48 & CU60 SERIES COMPACT UNDERCOUNTER FOOD STORAGE CABINETS (Kansas City) Machines Starting With Serial Number 32XXXXXXX CU48 REFRIGERATOR CUG48 FREEZER CUS48 REFRIGERATOR
More informationSERVICE PARTS/OPERATION for
T--357 Manual SERVICE PARTS/OPERATION for MCC Heater Units 12-XXXX Series T -357 REV. 05/2015 2012 Mobile Climate Control Table of Contents SAFETY SUMMARY... Safety-1 UNIT SPECIFICATIONS... Spec-1 MAINTENANCE...
More informationPart Lists & Exploded Views
Part Lists & Exploded Views Integrated (700-3 TALL) 700TF/I-3 DOOR PARTS LIST 1 11 Door Assy, RH (Hinges not include) 12 Door Assy, LH (Hinges not include) 2 322 Gasket, Door 3 30 Brkt, Door Panel Mtg
More informationInstallation Instructions
Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A, Z Chassis Installation Instructions NOTE: Read the entire instruction manual before starting
More informationSPECIFICATIONS FOR ELECTRICAL INSTALLATIONS
Attachment PUC 4-8-5 Page 1 of 26 SUPPLEMENT TO SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS PRIMARY METER POLE ELECTRIC SYSTEM BULLETIN No. 753 JUNE 1993, 2ND PRINTING APRIL 2002 (Supersedes issue dated
More informationINSTALLATION INSTRUCTIONS PT-A HEAT/AC STANDARD KIT FORD E-SERIES VANS
INSTALLATION INSTRUCTIONS PT-A-402 - HEAT/AC STANDARD KIT 2007-2014 FORD E-SERIES VANS with Gas engine (To be used with 2007 and newer Prisoner Transport Inserts ONLY) Warning do not attempt to install
More informationB. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationSECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.
SECTION 16470 PANELBOARDS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16120 - Wire and Cable. 3. 16475 - Overcurrent Protective Devices. 1.02 SYSTEM DESCRIPTION A. Performance
More informationRepair Parts List DRYER MODEL NUMBER MDG32PC3AW. When requesting service or ordering parts, always provide the following information:
Repair Parts List DRYER MODEL NUMBER MDG32PC3AW When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description 2005
More informationAGITATOR V DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY
AGITATOR 20 120V INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always use
More informationDEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS
DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS Models: DM-813-PLLL-1T DM-813-PDLL-1T DM-813-PLLL-2T DM-813-PDLL-2T I-729 Pg 1 of 15 System Overview The DEMA DEMAMaster probeless series is designed
More informationPERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP
specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1960-66 FORD PICKUP CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect
More informationHakki Pilke Raven spare parts manual
1 ENGLISH Hakki Pilke Raven spare parts manual Valimotie 1, FI-85800 Haapajärvi, FINLAND Tel. +358 8 772 7300, Fax +358 8 772 732 info@maaselankone.fi, www.maaselankone.fi 2 Table of contents 1 Upper section
More informationMODEL X-150D SUB-ASSEMBLY PARTS LIST REV. 02/27/04
MODEL X-D SUB-ASSEMBLY PARTS LIST REV. 0//0 MAINFRAME ASSEMBLY X-D DECO ITEM PART NUMBER DESCRIPTION QTY 0 --0-00 Mainframe, X ---00 Rollcage, X -0-00-0 HHB, /-0 x / -G0-0- HHB, /- x / -0-00-0 HHB, /-0
More informationMODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B
MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com
More informationService Parts Manual International Pro-Series (Model ICB648PRO)
1 11 1 1 1 1 1 1 1 0 1 1 1 1 0 1 0 1 1 1 1 1 International Pro-Series (Model ICBPRO) SUB-ZERO FREEZER COMPANY INC. 00 ALL RIGHTS RESERVED JOB AID #00 (Revision A - April, 00) International Pro-Series (ICBPRO)
More informationTW Compact Accessoires-Carpet tool, 2-nozzles. As at: 01/18/10 Time:18:16
Accessoires-Carpet tool, 2-nozzles As at: 01/18/10 Time:18:16 Accessoires-Carpet tool, 2-nozzles As at: 01/18/10 Time:18:16 Pos. Description Reference 01 Carpet tool complete, including items 2-22 602.000
More informationCT CABINET AND UTILITY METERING WELL AND BOOSTER PUMP CONTROL 12"x12" WIREWAY 200A MCB 200A, 120/208V, 3Ø, 4W BOARD TVSS CIA ALARM 400A, DOUBLE-THROW SWITCH PORTABLE GENERATOR CONNECTION ENCLOSURE EXISTING
More informationFilabot EX6 Extruder. Operation Manual. CAUTION! Read Carefully. Filabot Vermont, USA, Earth
Filabot Vermont, USA, Earth 1-802-505-6772 CAUTION! Read Carefully HOT MATERIALS & SURFACES Use gloves and eye protection while operating the EX6 Extruder. The barrel and nozzle are HOT and melted plastic
More informationTOOLS REQUIRED: Crimping tool A/C Recovery Unit Wrench set up to 1 ¼ 4 Hole saw
INSTALL INSTRUCTIONS PT-A-401 HVAC UNIT for 2003-2018 CHEVROLET/GMC VAN (For 2007 ALL WHITE Prisoner Transport Inserts ONLY) Not Recommended for diesel engine application because of lack of space needed
More informationPart Lists & Exploded Views
Part Lists & Exploded Views Integrated (00-3 TALL) 3TR-3 DOOR PARTS LIST 1 51 Door Assy, 3 RH 52 Door Assy, 3 LH 2 323 Gasket, Door 3 32 Brkt, Door Panel Mtg Handle Side 0 Screw, #8- x 1/2 PH Truss HD
More information48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual
8 Vanguard Belt Drive Fans Installation and Operators Instruction Manual Thank You The employees of Chore-Time Equipment would like to thank your for your recent Chore-Time purchase. If a problem should
More informationFor more Parts Information: https://manitowocfsg.sysonline.com/default.aspx
For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx TABLE OF CONTENTS Manitowoc Foodservice [Updated: Sep. 30, 2013] Manitowoc - Ice & Related Parts Catalog Ice Machine Q Series
More informationSmoke Vent with Manual Winch. Installation, Operation and Maintenance
Smoke Vent with Manual Winch I. Overview Smoke vents are used, upgraded with manual winches, typically installed in theater applications. The winch is used to manually close the smoke vent from a remote
More informationA. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationPACER 30 VACUUM IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE OPERATING OR SERVICING MACHINE
DANGER! PACER 30 VACUUM IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE OPERATING OR SERVICING MACHINE Failure to Observe These Instructions Can Cause Fire, Electrical Burn, Shock
More information