Corporation , Soraji-ro, Paju-si, Gyeonggi-do, Republic of Korea (Postal Code: 10863)
|
|
- Byron Cummings
- 5 years ago
- Views:
Transcription
1 Corporation Company Information 01 Company Gfutec Corporation. (October. 08th, 2009.) 02 Location Head Office 34-, Soraji-ro, Paju-si, Gyeonggi-do, Republic of Korea (Postal Code: 10863) 03 Contact Tel : +82-(0) Fax : +82-(0) info@gfutec.com Certiÿcate ISO 9001 ISO 101 Ex-Proof HVAC KTL KGS ATEX
2 HVAC Hazardous Location Ex-proof HVAC Heating Ventilation & Air Conditioners Wall Mount Type HVAC ATEX Certificate : II 3 G Ex db ec ia pzc IIB + H2 T3 Gc KCs Certificate : Ex na d ia pz IIB+H2 T3 or T4 Description Gfutec s HVAC system is used for Analyzer shelter and control room which located at high danger of explosion environment such as refinery and chemical plant. HVAC can control temperature, circulate air and maintain positive pressure by fresh air aspirated from safety area for the interior of shelter. Temperature is auto-controlled cooling and heating by setting and the type of heater must be selected either electric or steam during equipment selection. HVAC is all in one for indoor and outdoor which is installed at shelter outside. It can be directly wall mounted or installed at duct as well. HVAC can be operated right after its installation without refrigerant injection. 01
3 GAH (ATEX) ATEX Certificate : II 3 G Ex db ec ia pzc IIB + H2 T3 Gc Characteristics The equipment is made of galvanized steel with coating, stainless steel AISI-304 or 316 with great thickness, the inside of the equipment is covered with a insulation of 12 mm fire resistant, being the equipment suitable to be placed in an exterior environment. High efficiency interchange are made of copper pipes and aluminum fin type tube with a separation of 2.1mm. The Air filters placed in the air capture and air recirculation zones have a high power filtration and have been assembled allowing an easy access and substitution. Blower fan and condenser fan are driven by Ex d motor and connected directly. Fully redundant blower fan. Ambient Temperature : -20 to C (Heating -20 to C) Low ventilation DP switch Compressor anti-short cycle protection. Optional Stainless steel 304 or 316 cabinet. Industrial coatings on tube coils and finned for additional corrosion protection. Copper-finned copper tube coils. Electric heat (see brochure with electric heat.)/ Steam heating coil. Fresh air inlet hood or stack with bird screen and rain cap. General purpose HVAC. Compressor anti-short cycle protection. Electric Heating Type Specification GAH-030K-Exx-4X GAH-050K-Exx-4X GAH-070K-Exx-4X GAH-110K-Exx-4X GAH-030K-Exx-3X GAH-050K-Exx-3X GAH-070K-Exx-3X GAH-110K-Exx-3X COOLING CAPACITY HEATING CAPACITY ELECTRICAL CHARACTERISTICS 33,000,000 75, ,000 27,000 65, ,000 9,700 17,0 22,000 36,0 7,900 14,0 19,000 30,200 16,0 49,200 16,0 49,200 4,800 14,0 4,800 14,0 VOLTS / PH / Hz CAPACITY 7.1 Kw / 8.9 A 13 Kw / 16A 14 Kw / 18A 20 Kw / 25A 7.1 Kw / 10 A 13 Kw / 19A 14 Kw / 20A 20 Kw / 29A Steam Heating Type Specification COOLING CAPACITY ELECTRICAL CHARACTERISTICS VOLTS / PH / Hz CAPACITY GAH-030K-S-4X 33,000 9, Kw / 8.9 A GAH-050K-S-4X,000 17,0 13 Kw / 14A GAH-070K-S-4X 75,000 22, Kw / 18A GAH-110K-S-4X 125,000 36,0 20 Kw / 25A GAH-030K-S-3X 27,000 7, Kw / 10 A GAH-050K-S-3X 14,0 13 Kw / 16A GAH-070K-S-3X 65,000 19, Kw / 20A GAH-110K-S-3X 103,000 30, Kw / 29A 02 Gfutec Corporation First Leading Supplier for Analyzer System Integration and HVAC System
4 Equipment selection GAH XXXK XXX XX GAH COOLING CAPACITY (BTU/H) ,000 or 33, or,000 HEATING TYPE E ELECTRIC S STEAM ELECTRIC HEATING CAPA. (W/H) 01 1,0 (030K 1,200) 02 3,200 (030K 2,0) POWER SELECTION (VAC) 35 0 ± 10%/ 50Hz 36 0 ± 10% / Hz ,000 or 75, ,800 (030K 3,0) 45 4 ± 10% / 50Hz ,000 or 125, ,0 (030K 4,800) 46 4 ± 10% / HZ 05 8, , , ,0 00 STEAM Dimensional specifications WIDE(A) DEPTH(B) HEIGTHT(C) D E F G H CUTTING SIZE GAH-030K X 700 GAH-050K 0 10 X1000 GAH-070K 0 10 X 1000 GAH-110K X 1000 A C H G G G G G F B Top side view D E Left side View Front side view Right side view Rear side view 03
5 GHWS (KCs) KCs Certificate : Ex na d ia pz IIB+H2 T3 or T4 GHWG Model (General purpose HVAC) Characteristics The equipment is made of galvanized steel with coating, stainless steel AISI-304 or 316 with great thickness, the inside of the equipment is covered with a insulation of 12 mm fire resistant, being the equipment suitable to be placed in an exterior environment. High efficiency interchange are made of copper pipes and aluminum fin type tube with a separation of 2.1mm. The Air filters placed in the air capture and air recirculation zones have a high power filtration and have been assembled allowing an easy access and substitution. Blower fan and condenser fan are driven by Ex d motor and connected directly. Auxiliary blower for rapid fresh air ventilation. Ambient Temperature : -20 to C Low ventilation air flow switch Optional Stainless steel 304 or 316 cabinet. Industrial coatings on tube coils and finned for additional corrosion protection. Copper-finned copper tube coils. Electric heat (see brochure with electric heat.)/ Steam heating coil. Fresh air inlet hood or stack with bird screen and rain cap. Compressor anti-short cycle protection. General purpose HVAC. Single Frame 100% redundant HVAC. Electric Heating Type Specification GHWS-030K-Exx-4X GHWS-050K-Exx-4X GHWS-070K-Exx-4X GHWS-110K-Exx-4X GHWS-030K-Exx-3X GHWS-050K-Exx-3X GHWS-070K-Exx-3X GHWS-110K-Exx-3X COOLING CAPACITY HEATING CAPACITY ELECTRICAL CHARACTERISTICS 15,000 52,200 15,000 52,200 4,0 15,300 4,0 15,300 VOLTS / PH / Hz CAPACITY 5.1 Kw / 6.4 A 11 Kw / 14A 11 Kw / 14A 16 Kw / 20A 5.1 Kw / 7.8 A 11 Kw / 17A 11 Kw / 17A 16 Kw / 24A Steam Heating Type Specification GHWS-030K-Exx-4X GHWS-050K-Exx-4X GHWS-070K-Exx-4X GHWS-110K-Exx-4X GHWS-030K-Exx-3X GHWS-050K-Exx-3X GHWS-070K-Exx-3X GHWS-110K-Exx-3X COOLING CAPACITY ELECTRICAL CHARACTERISTICS VOLTS / PH / Hz CAPACITY 5.0 Kw / 6.3 A 8 Kw / 10A 10 Kw / 13A 16 Kw / 20A 5.0 Kw / 7.6 A 8.0 Kw / 12A 10 Kw / 15A 16 Kw / 24A 04 Gfutec Corporation The leader of Analyzer System Integrator & HVAC System
6 Equipment selection G H W S X X X K X X X X GHWS COOLING CAPA. (BTU/H) 030 HEATING TYPE E ELECTRIC ELECTRIC HEATING CAPA. (W/H) 01 1,700 (030K 1,100) POWER SELECTION (VAC) 3 3P / 380 ± 10% / Hz GHWG 050 S STEAM 02 3,0 (030K 2,200) 4 3P / 4 ± 10% / Hz ,100 (030K 3,300) ,800 (030K 4,0) 05 8, , , , or STEAM Dimensional specifications WIDE(A) HEIGHT(B) DEPTH(C) D E SUPPLY AIR RETURN AIR CUTTING SIZE (G x H) CUTTING SIZE (F x H) GHWS-030K X X 700 GHWS-050K 10 X X1000 GHWS-070K 10 X X 1000 GHWS-110K X X
OPTA-PERIPH 8 Av. de Bretteville Neuilly - France 33(0) Fax : 33(0) Document: IM By PB Date: 18/11/2005
OPTA-PERIPH 8 Av. de Bretteville 92 200 Neuilly - France 33(0)6 85 43 82 78 - Fax : 33(0)6 07 18 28 07 User: AIR CONDITIONER ATEX CE II 3G Supplier : OPTA-PERIF Ref : Q/N 0510278 Rev.: 0 Document: IM 050312
More informationVAC1 Series - Division 2 / Zone 2
VAC1 Series - Division 2 / Zone 2 Wall Mount Explosion Proof Air Conditioner System CSA Certified For Use in Division 2 Hazardous Locations 50 Hertz s 21,200 59,000 60 Hertz, High Ambient, & Custom Designs
More informationMHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH
MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:
More informationMHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH
MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH
More informationHigh Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)
High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year
More informationGeneral Description. Operation
ECUA12ACA & ECUA18ACA SlimPac (1 & 1.5 Ton) Environmental Control Units General Description The Industrial Climate Engineering SlimPac line of Environmental Control Units (ECU) are designed for the telecommunication
More informationDSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal
More informationVAC1 Series-Division 2 / Zone 2
VAC1 Series-Division 2 / Zone 2 Wall Mount Explosion Proof Air Conditioner System CSA Certified For Use in Division 2 Hazardous Locations 60 Hertz s 21,200 59,000 60 Hertz, High Ambient, & Custom Designs
More information50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT
50HJQ-11SB 50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION
More informationHigh Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy
More informationMHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH
MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000
More informationproducts 22 º C Ventilation Air Conditioning Refrigeration Unit heaters Inside PROVIDED BY HEINEN & HOPMAN
products > Unit heaters OUTSIDE 5 C HUMIDITY 90% 22 º C Inside PROVIDED BY HEINEN & HOPMAN Heating Ventilation Air Conditioning Refrigeration unit heaters Unit heaters The unit heaters are primary used
More informationMIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/
1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5
More information50TM TFF COMBINATION HEATING/COOLING UNITS
50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York
More informationCFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH
CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal
More informationCFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH
CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal
More informationCFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH
CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal
More information50TM COMBINATION HEATING/COOLING UNITS
50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form
More information48TF GAS HEATING/ ELECTRIC COOLING UNITS
48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form
More informationCompact, Self-Contained unit that offer low installation cost plus dependable performance.
0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water
More informationCondensing Units & Air Handlers
Condensing Units & Air Handlers 13 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice. Copyright
More informationFALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)
FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz
More informationTECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental
TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer
More information48TM GAS HEATING/ELECTRIC COOLING UNITS
48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form
More informationV ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless
More informationRooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION
PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY
More informationMidea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual
Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without
More information48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS
48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY 48GS(N)-2SB SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION
More informationMARVAIR COMPAC AIR CONDITIONERS MODELS AVP72AC AND AVPA72AC EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS)
EXTERIOR SHEET METAL (OUTER PANELS) 1 COMPAC AVP72/AVPA72 PARTS LIST, 03/09 EXTERIOR SHEET METAL (OUTER PANELS) AVP72AC AVPA72AC 1 Panel, Back (Galvanized) M/04443SP 2 Right Side Panel, ComPac II M/04465XXSP
More informationSUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #
Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # Page 1 of 7 Performance Power Compressor 95 F Ambient, Entering Temperature: 54 F, Leaving
More informationMHCFC4W Chilled/Hot Water Cassette Fan Coil
MHCFC4W-16-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.1 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 48,000 BTUH Multiaqua
More informationMHCFC4W Chilled/Hot Water Cassette Fan Coil
MHCFC4W-04-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 12,000 BTUH Multiaqua
More informationMHCFC4W Chilled/Hot Water Cassette Fan Coil
MHCFC4W-08-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.1 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua
More information50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out
50Hz AC, HP and Air Handler Units Up to 70 kw T-Class Commercial Split Systems TSA/TPA and TAA Models Reliable, cost-effective and servicefriendly split systems inside and out Lennox units deliver comfort
More informationSeries PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection
Series PIN New Construction or Renovation Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction or Renovation The Adirondack-Aire PIN Series zerozone chassis provides environment
More informationICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS
0 ICE AIR LLC HARTFORD AVENUE, MOUNT VERNON, NY 10553 WEBSITE: http://www.ice-air.com TEL: (914) 668-4700; FAX: (914)668-5643 Draw1 REV. - 117/133 SENS HEAT RATIO, % TOTAL COOL CAP; % 120 110 COOLING CAPACITY
More informationMHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH
MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed
More informationPAJ3. Product Specifications
13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,
More information48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS
48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,
More informationExplosion Proof Hazardous Location Roof Top A/C Units
Explosion Proof Hazardous Location Roof Top A/C Units RT-XPC Series RT-XPC Series Roof Top Air Conditioning Systems are designed to Provide Maximum Indoor Comfort while meeting the demanding requirement
More informationGeneral Description. Safety Listed
ECUA90/120/150/180/240 & ECUDA180/240/300/360 (7.5, 10, 12.5, 15, 20, 25 & 30 Ton) Vertical Wall Mount Air Conditioners General Description Industrial Climate Engineering s air conditioners are used primarily
More informationGeneral Description. Safety Listed
ECUA90/120/150/180/240 & ECUDA180/240/300/360 (7.5, 10, 12.5, 15, 20, 25 & 30 Ton) Vertical Wall Mount Air Conditioners General Description Industrial Climate Engineering s air conditioners are used primarily
More informationMARVAIR COMPAC AIR CONDITIONERS MODELS AVP EXPLODED VIEW PARTS ID
EXTERIOR SHEET METAL (OUTER PANELS) 1 Panel, Back (Galvanized) M/04996-SP 2 Door, Front Top M/01294-XXSP 3 4 Door, Front Bottom w/slots 1,2 (shown) Door, Front Bottom w/ext. Fresh Air Hood (not shown)
More informationPAR5. Product Specifications
TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced
More informationUP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT
SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A
More informationWLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)
WLCG/WLHG R-410A High-Efficiency Ductless Split System High-Wall Air Handlers Straight cool / Heat pump nominal capacities WLHG09 WLHG12 WLHG24 Units 9,000 12,000 18,000-23,800 Btuh 2.6 3.5 5.3-7.0 kw
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
016---028 Single---Package Cooling Units with Factory---Installed Optional Electric Heat Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION
More informationAC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out
AC, HP and Air Handler Units Up to 20 Tons T-Class Commercial Split Systems TSA/TPA and TAA Models Reliable, cost-effective and servicefriendly split systems inside and out Lennox units deliver comfort
More informationCapacity: 1.5 to 6.0 Ton
VACPB1 Series Wall Mount Explosion Proof Air Conditioner and Room Pressurization System Hazardous Location N.E.C. and I.E.C. Approved 50 Hertz Models 60 Hertz, High Ambient, & Custom Designs Available
More informationCapacity: 1.5 to 6.0 Ton
VACPB1 Series Wall Mount Explosion Proof Air Conditioner and Room Pressurization System CSA Certified for Use in Division 2 Locations 60 Hertz Models 50 Hertz, High Ambient, & Custom Designs Available
More informationINFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY
INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY >OLYL >H]LSLUN[O 4H[[LYZ SMOKELESS FLARE MONITOR Smokeless Flare Monitor (FM) Smokeless flares incinerate flammable hazardous
More informationRoof top SPACE RPC 315Z R407C MA00
Client : TIHE SERV Contact : Romeo Staicu Your reference : Your contact : Phone : E-mail : Page : 1 / 6 Roof top SPACE RPC 315Z R407C MA00 Independant roof mounted unit, cooling only, ready to be installed,
More informationOil & Gas Case History
Unit Type: Air Handling Unit & Compressor Skid (AHU+CSV) Project Name: FGP LER Substation 51 Cooling Duty: No. 2 x 228 kw Site Location: Kazakhstan Year: 2017 End User: TengizChevrOil Manufacture of 2
More informationHigh Heat COP. High/Low Stage
SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin
More informationCWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH
CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH 233 CWA2 NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool with Electric Heat Multiposition Fan Coil Nominal
More informationRetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)
Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package
More information13 SEER CONDENSING UNITS & AIR HANDLERS
13 SEER CONDENSING UNITS & AIR HANDLERS (GC201305-I) TTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CON TECHNICAL SALES GUIDE-60Hz CAPACITY RANGE:11/2~5
More informationART الرفاهية تكنولوچيا بلمسة فنية
ART 010-012 الرفاهية تكنولوچيا بلمسة فنية Air Conditioner Outdoor Unit Features: Fast installation and easy maintenance. Modern cabinet design to suit the building decorations. Low-noise, high efficiency
More informationBRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01
b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a
More information2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil
Specification 2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation,
More informationMODEL IX-WAC AIR CONDITIONERS FOR HAZARDOUS & HIGHLY CORROSIVE AREAS
1.5, 2, 2.5, 3, 3.5, 4, 5 & 6 Ton Industrial Grade Wall Mounted Air Conditioners Unit Application ebco Model IX-WAC Industrial Grade Air Conditioners are designed as a top-of-the-line highly qualified
More informationWeathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS
48HJ-13SB Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationMH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil
MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 18,000
More informationTECHNICAL SPECIFICATIONS B6VMMX
TECHNICAL SPECIFICATIONS BVMM Series Air Handler with TV, -, Btuh (Heat Pump & Air Conditioner) R-4A Refrigerant The BVMM Series of air handlers, when combined with our heat pump or air conditioner, offers
More information50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT
-1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION
More informationRoof top SPACE RPC 450Z R407C M011
Roof top SPACE RPC 450Z R407C M011 Page : 1 / 5 Independant roof mounted unit, cooling only, ready to be installed, designed for air conditioning of large volumes for industrial or commercial use. As per
More informationGP SERIES Packaged Chillers
Material Handling Process Cooling Temperature Control Size Reduction Temperature Control Process Cooling Material Handling Size Reduction GP SERIES Packaged Chillers Precision Comprehensive Engineered
More informationWALL-MOUNT HEAT PUMPS - (60HZ)
WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to 5,000 Cooling Capacities:,00 to 5,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling
More informationWATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED
EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units
More informationair systems Roomtop RTC-RTH 15 to 30 - L
air systems Roomtop RTC-RTH 15 to 30 - L york air-conditioning products Roomtop RTC-RTH - L A complete range from 14.6 kw up to 27.0 kw YKN2open Features New YKN2open board Possibility to be installed
More informationProduct Data. Fig. 1 - Unit 50VR -A
50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged
More informationDCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners
DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER
More information48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS
-3SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING S PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier Corporation
More informationDCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER
DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER
More informationT-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models
T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models UP TO.7 EER Lennox units deliver comfort and control that you can depend on The latest offerings from Lennox represent a new design in air conditioners
More informationKlimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE
Klimaire 16 SEER CENTRAL DUCTED Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units 10 YEAR LIMITED GUARANTEE R410A R E F R I G E R A N T CSM Condensing Units Features Condensing
More information1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series
1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor
More informationSpaceKeeper Console (SKC)
SpaceKeeper Console (SKC) With finished cabinet or custom enclosure SKC 008-015 ¾ - 1¼ tons 12 W x 25¼ H x 48 L CGC-09 SpaceKeeper Console R410A MODEL NO. SKC _ 008 010 012 015 Net Cooling Capacity - Rated
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON
More informationHi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.
R407C 220-240V ~, 50Hz Hi - Wall Split Systems Technology Tropical Compressor Super Quiet Auto Mode Auto Restart Easy Flexible Installation IAQ Anti-dust Filters AMS AMS Wireless Control Independent Dehumidification
More informationDSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data
DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 25,240* Design CFM: 800 Seasonal
More informationPRODUCT DATA SHEET. Models ASDCA/HSDCA & ASDCHA
PRODUCT DATA SHEET DC Free Air HVAC Unit w/48 VDC Evaporator Fan Motor, 00% Free Cooling and CoolLinks Controller Models ASDCA/HSDCA36-42-48-60-72 & ASDCHA36-42-48-60 General Description The Marvair ComPac
More informationProduct Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons
007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),
More informationProduct Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz
Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece
More informationExp, pressurized systems
Exp, pressurized systems ATEX approved Principle, requirements and recommendation Exp, explosion protected systems The principle of a pressurized apparatus The entry of a surrounding atmosphere into the
More informationMAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with Puronr (R---410A) Refrigerant Sizes: 17, 20, 24, 28, 30 Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION
More informationConcealed Ducted Split Series R-407C MBH
Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY
More informationIndoor Air Handlers with Compressors MVS and MVW
Indoor Air Handlers with Compressors MVS60-90-120-144 and MVW60-90-120-144 General Description The Marvair Marine self-contained water and air cooled air conditioners are designed for both new installations
More informationSUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP
VEP075N432G Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Access to electrical box for ease of
More informationProduct Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS
Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air
More informationHazardous Location Certified
Certified. Not Modified. EONA2-72 and EXNDA/EONDA90-240 2,000 BTUH (3.5Kw) to 240,000 BTUH (70.3Kw) Increased Safety Vertical Wall Mount Air Conditioners General Description EXNA60 The old approach to
More informationPerformance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models
T-Class Performance and rugged durability Commercial Split Systems Up to 20-Ton TSA/TPA Models Up to.7 EER Lennox units deliver comfort and control you can depend on Lennox proven design in air conditioners
More informationmaintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.
AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the
More informationOPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling
MORE n More efficient n More flexible n More intelligent for LESS n Less energy n Less time n Less noise Capacity: up to 1100 kw 410A 407C 134a 404A Free cooling Water misting Use The range, available
More informationCWA4 Chilled & Hot Water Fan Coil
CWA4 Chilled & Hot Water Fan Coil 4-Pipe Heat & Cool Fan Coil 24,000-60,000 BTUH 259 CWA4 NOMENCLATURE BREAKDOWN 4-Pipe Heat & Cool Multiposition Fan Coil Nominal BTUH 24=24,000 36=36,000 48=48,000 60=60,000
More informationDCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h
Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: DCC Commercial 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling
More information