PRODUCT SELECTION GUIDE

Size: px
Start display at page:

Download "PRODUCT SELECTION GUIDE"

Transcription

1 PRODUCT SELECTION GUIDE GLASS STILLS Product Dimensions** Feed Output HxWxD Water Type of Type of Optional LPH Inches (cm) Type Still Mounting Reservoir Page MEGA-PURE 1 MEGA-PURE 3A MEGA-PURE 6A MEGA-PURE 11A MEGA-PURE 12A FI-Streem II 2S FI-Streem III 4 Liter/Hour FI-Streem III 8 Liter/Hour x 18 x 9.75 Tap* Glass Wall 9L Glass Bottle 202 (86.4 x 45.7 x 24.8) Bench 6L Plastic Bottle Automatic Collection System (45L) x 23 x 12 Tap* Glass Wall 13L Glass Bottle 202 (114.3 x 58.4 x 30.5) Bench 9L Glass Bottle 6L Plastic Bottle Automatic Collection System (45L) x 23 x 12 Tap* Glass Wall 13L Glass Bottle 2202 (114.3 x 58.4 x 30.5 ) Bench Automatic Collection System (45L) x 29 x 14 Tap* Glass Wall 45L Glass Bottle 202 (136.6 x 73.7 x 35.6) Bench Automatic Collection System (45L) x 29 x 14 Tap* Glass Wall 45L Glass Bottle 202 (136.6 x 73.7 x 35.6) Bench Automatic Collection System (45L) 1.5 and x 10.5 x 13.8 Tap/Pretreated Glass Wall 8L Plastic Bottle 207 (79 x 26 x 35) Bench 30L Storage Reservoir x 12 x 15 Tap/Pretreated Glass Wall 30 Liter Storage Reservoir 207 (74.9 x ) Bench 50 Liter Storage Reservior x 19 x 15 Tap/Pretreated Glass Wall 30 Liter Storage Reservior 207 (74.9 x 48.3 x 38.1) Bench 50 Liter Storage Reservior FI-Streem III Bi-Distiller BI-DISTILLER x 19 x 15 Tap/Pretreated Glass Wall 30 Liter Storage Reservoir 208 (74.9 x 48.3 x 38.1) Bench 50 Liter Storage Reservoir * Accessories available for pretreatment, page 46. ** Bench Dimensions MEGA-PURE FI-Streem Storage System

2 PRODUCT SELECTION GUIDE ELECTRIC CLASSIC STILLS Product Dimensions Feed Output WxDxH Water Type of Type of Optional LPH Inches (cm)** Type Still Mounting Reservoir Page x 10 x 19 Tap* Metal Bench 10 Gallon Tin Coated 210 (53 x 26 x 49) Cylindrical Tank Electric Classic Stills x 10 x 20 Tap* Metal Bench 10, 25, 50, 100, 200 Gallon Tin 210 (55.9 x ) Wall Coated Cylindrical Tanks Floor 25, 50 Gallon Tin Coated Rectangular Tank x 11 x 35 Tap Metal Bench 10, 25, 50, 100, 200 Gallon Tin 210 (58.4 x 27.9 x 88.9) Wall Coated Cylindrical Tanks Floor 25, 50 Gallon Tin Coated Rectangular Tanks x 14 x 45 Tap Metal Bench 10, 25, 50, 100, 200 Gallon Tin 210 (89 x 36 x 114) Wall Coated Cylindrical Tanks Floor 25, 50 Gallon Tin Coated Rectangular Tanks x 14 x 58 Tap Metal Bench 10, 25, 50, 100, 200 Gallon Tin 210 (109 x 36 x 147) Wall Coated Cylindrical Tanks, Floor 25, 50 Gallon Tin Coated Rectangular Tanks STEAM CLASSIC STILLS Steam Classic Stills x 18 x 43 Tap Metal Bench 10, 25, 50, 100, 200 Gallon Tin 210 (78.7 x 45.7 x 109.2) Wall Coated Cylindrical Floor Tanks, 25, 50 Gallon Tin Coated Rectangular Tanks x 19 x 58 Tap Metal Bench 10, 25, 50, 100, 200 Gallon Tin 210 (88.9 x 48.3 x 174.3) Wall Coated Cylindrical Tanks, Floor 25, 50 Gallon Tin Coated Rectangular Tanks CABINETIZED STILLS Cabinetized Stills x x 41 Tap Metal Bench 10 Gallon Tin Coated 216 (60 x 39 x 102.5) Wall Retangular Tank Floor Complete with unit x x 48 Tap Metal Bench 25 Gallon Tin Coated 216 (91.4 x 47.6 x 121.9) Wall Rectangular Tank Floor Complete with unit. * Accessories available for pretreatment, page 46. ** Bench Dimensions Classic Stills Cabinetized Stills

3 W H A T I S D I S T I L L A T I O N? Distillation differs from other forms of water purification because water is removed form the impurities rather than the impurities rather than the impurities from the water. Water undergoes phase changes during the process, changing from liquid to vapor and back to liquid. It is the change from liquid to vapor that prompts a separation of water from its impurities. Impurities with a boiling point higher than water (100 C) remain in the boiler.. Water and impurities with a boiling point equal to or lower than water are converted to water vapor. When this vapor is condensed, only water and a few substances that boil at lower temperatures than water remain. How Well Does Distillation Work? Distillation has the broadest capabilities of any single form of water purification. Distillation effectively removes most inorganic solids, all organics with a boiling point greater than water (100 ), all bacteria and pyrogens. Gases and other organics are not removed by distillation. They undergo the same phase changes as the hydrogen and oxygen ions and can be removed before and after distillation using other technologies. What Types of Stills Are Available From Barnstead? Barnstead stills range in size from 2 to 38 liters per hour. They can be constructed of metal or glass. You can purchase a single distillation unit or a glass double distiller. Most laboratories in the world use distilled water. Still Components A still includes a boiling chamber (boiler), electric immersion heaters, pyrogen reducing baffle, condenser and constant level device. Optional accessories include electric inlet valve, low water cutoff, electric drain valve and a fully automatic control for the still to work with pretreated feedwater and a storage tank.

4 P R I N C I P L E S O F D I S T I L L A T I O N STEP-BY-STEP TECHNOLOGIES USED IN BARNSTEAD DISTILLATION SYSTEMS 1. Cooling water Feedwater inlet Water enters the condenser for two purposes: (a) to cool the vapor entering the condenser. (b) to provide a warmed source of water for the boiler. 2. Water flows from the condenser into the constant level device, then into the boiler. The constant level device maintains the proper water level in the boiler. 3. The water in the boiler is heated, producing pure vapor that moves up the boiler through a pyrogen reducing baffle and into the condenser tubing. The baffle removes contaminantladen water droplets from the vapor. 4. In the condenser, the pure vapor tubes contact the cooler condenser inlet water. The pure vapor condenses into water and the product is distilled water. 5. Distilled Water Outlet The distilled water exits the condenser and is stored in a tank.

5 M E G A - P U R E G L A S S S T I L L S With a nickname like the tissue culture still it aptly illustrates the kind of trust lab pros place in MEGA-PURE glass stills and purity products. Why? How about easy operation, economical pricing, and consistent quality of Type II distilled water. Or that you can choose five production volumes, from 1.4 to 13 liters per hour. Integrity. It s built into every Barnstead product. All glass system Only non-leaching components are used Choice of 5 production capacities Wall and bench mountable BENEFITS Mega-Pure Glass Stills MP-1 Compact, easy-to-use glass still available with or without a storage bottle. Vertical condenser design provides maximum purity. Only Pyrex, Vycor, and Teflon components used to ensure ultimate purity. High temperature cut-off shuts down the glass still if temperature is too high, preventing heating element burnout. Quick release cover for easy cleaning access. Can be connected to Automatic Collection System (ACS) for a 24 hour automatic system. Can be wall or bench-mounted depending on lab space requirements. Includes feedwater solenoid valve for automatic operation. UL and CSA approved. MP-3A, MP-6A, MP-11A Vertical condenser design provides maximum purity. High temperature cut-off shuts down the glass still if temperature is too high, preventing heating element burnout. Only Pyrex, Vycor, and Teflon components used to ensure ultimate purity. Quick release cover for easy cleaning access. Can be connected to Automatic Collection System (ACS) for a 24 hour automatic system. Can be wall or bench-mounted depending on lab space requirements. Includes feedwater solenoid valve for automatic operation. UL and CSA approved. MP-12A Vertical condenser design provides maximum purity. High temperature cut-off shuts down the glass still if temperature is too high, preventing heating element burnout. All Pyrex, Vycor, and Teflon components for ultimate purity. Quick release cover for easy cleaning access. Can be connected to Automatic Collection System (ACS) for a 24 hour automatic system. Can be wall or bench-mounted depending on lab space requirements. Includes feedwater solenoid # valve for automatic operation. Built-in deionizer for pretreated feed to boiler. Distillate cooler allows product water to be used as it is produced no need to wait for cooling. UL and CSA approved. Pyrex and Vycor are registered trademarks of Corning, Inc. Teflon is a registered trademark of DuPont Co. #413964

6 M E G A - P U R E G L A S S S T I L L S MEGA-PURE Glass Stills Overall Dimensions Weight Product Water Electrical Cooling Water Inches (cm) Lbs (kg) # of Model # Capacity (50/60 Hz) Amps Capacity W D H Operating Ship Heaters Special Features Price A (MP-1) 1.4 LPH 120 V LPH 18 (45.7) 9.75 (24.8) 34 (86.4) 40 (18) 29 (13.2) 1 A7981 (MP-1) 1.4 LPH 240 V LPH 18 (45.7) 9.75 (24.8) 34 (86.4) 40 (18) 29 (13.2) 1 A (MP-1) 1.4 LPH 120 V LPH 18 (45.7) 9.75 (24.8) 34 (86.4) 65 (29.5) 31 (14.1) 1 Includes 6 liter bottle A7982 (MP-1) 1.4 LPH 240 V LPH 18 (45.7) 9.75 (24.8) 34 (86.4) 65 (29.5) 31 (14.1) 1 Includes 6 liter bottle A (MP-3A) 3.4 LPH 240 V LPH 23 (58.4) 12 (30.5) 45 (114.3) 85 (38.6) 63 (28.6) 1 A (MP-3A) 3.4 LPH 208 V LPH 23 (58.4) 12 (30.5) 45 (114.3) 85 (38.6) 63 (28.6) 1 A (MP-6A) 6.0 LPH 240 V LPH 23 (58.4) 12 (30.5) 45 (114.3) 110 (49.9) 73 (33.2) 2 A (MP-6A) 6.0 LPH 208 V LPH 23 (58.4) 12 (30.5) 45 (114.3) 110 (49.9) 73 (33.2) 2 A (MP-11A) 13 LPH 240 V LPH 29 (73.7) 14.2 (36) 53 (136.6) 125 (56.7) 120 (55) 4 A (MP-11A) 13 LPH 208 V LPH 29 (73.7) 14.2 (36) 53 (136.6) 125 (56.7) 120 (55) 4 A (MP-12A) 12 LPH 240 V LPH 29 (73.7) 14.2 (36) 53 (136.6) 150 (65.4) 140 (64) 4 built-in deionizer and distillate cooler A (MP-12A) 12 LPH 208 V LPH 29 (73.7) 14.2 (36) 53 (136.6) 150 (65.4) 140 (64) 4 built-in deionizer and distillate cooler All units include high temperature cut-off to alert user to low boiler water level condition. All units designed only for operation on a single phase electric current. Standard Specifications Auto Feedwater Feedwater Condenser Water Product Vent Auto Maximum Inlet Minimum Inlet Start/Stop Type Temperature to Boiler Temperature Water Flow Rate Temperature Drain Pressure (psig) Pressure (psig) Controls tap/pretreated 15.0 to 16.0 C 60.9 C 50.0 ml/min to 96.7 C No Yes Additional Accessories required for use with pretreated feedwater Model # Descriptions Price Dual solenoid for use with in-house treated water supply (MP-3A, MP-6A, and MP-11A) Automatic still adapter - connect MP-3A, MP-6A, and MP-11A to MEGA-PURE deionizer for automatic operation RY798X2A Dual Solenoid (MP-1, 120V) Optional Storage Bottles (Non-automatic operation) Model # Capacity (L) Where Used Price Plastic bottle for MP-1 and MP-3A Glass bottle for MP-1 and MP-3A Glass bottle for MP-3A and MP-6A Glass bottle for MP-11A and MP-12A

7 M E G A - P U R E A C C E S S O R I E S - A C S You ll give rave reviews for this system s capacity to collect water and control the operation of MEGA-PURE Automatic Systems. As a team, ACS and MEGA-PURE can store up to 45 liters of Type II distilled water. Impressive. When water levels approach 45 liters or deplete to 38 liters, the ACS shuts off power or automatically restarts operations. Intelligent system. Smart purchase! All glass design with ACS ACS designed to collect water from Mega-Pure still Automatic Collection System (ACS) The MEGA-PURE Automatic Collection System is designed to collect water from the MEGA-PURE stills and control the operation of the MEGA-PURE Automatic Systems. This ACS will work with most MEGA-PURE stills to store up to 45 liters of Type II distilled water. The ACS is preset to shut off the power to the heaters and the water supply to the MEGA- PURE still after the bottle has collected approximately 45 liters. When the purified water supply has been depleted to 38 liters, the system will automatically restart the water still and refill the collection system. BENEFITS 45 liter capacity. Wall or bench mounted. All glass design. Glass inlet and out let tubing. When setting up a MEGA-PURE still with the ACS, a 6-12 stand (depending on still model) is needed to place still on. This will ensure proper gravity feed of distilled water. ACS Automatic Collection System Dimensions Weight Inches (cm) Lbs (kg) Model # Power W D H Operating Ship Capacity Price B None (41.3) (41.3) 38 (96.5) 110 (49.9) 55 (25.1) 45 liter ACS Accessories Model # Where Used Price Flexible Tubing Adapter Kit When Placing ACS in Unrecommended Set-up Wall Mounting Bracket for ACS Adapter for ACS Washer Hook-up for Glassware Washers Automatic Still Adapter Kit D6831 ACS to NANOpure Adapter

8 M E G A - P U R E A C C E S S O R I E S Choose from two deionization models Deionization system reduces scale impurities MEGA-PURE Deionizer D2 MEGA-PURE Cartridges MEGA-PURE Deionizer Overall Dimensions Weight Inlet Electrical Inches (cm) Lbs (kg) Recommended Max Pressure Model # Conn (Inches) Requirements W D H Operating Ship Cartridges (psig) Price D (D1) 3/8 OD 120 V 1 /4 Amp 10.5 (26.7) 7.5 (19) 25.5 (64.8) 26 (11.8) 22 (10) D D (D2) 3/8 OD 120 V 1 /4 Amp (42.6) 7.5 (19) 25.5 (64.8) 41 (18.6) 33 (15) D400499, D400377, and D Solenoid valve accessory (for D1 & D2 when stand alone system). MEGA-PURE deionizers are designed for pretreating feedwater to most MEGA-PURE still boilers. When using a MEGA-PURE deionizer in front of a still, it reduces the level of scale impurities entering the still, as well as the need for frequent cleanings. MEGA-PURE deionizers are available in two cartridge designs to allow greater flexibility in meeting varying feedwater qualities. A MEGA- PURE deionizer connected to a MEGA-PURE still allows for a completely automatic system. BENEFITS Temperature-compensated purity meter measures water quality and indicates when cartridges are exhausted. Flow valve precisely controls product flow. Built-in drain valve for no-spill cartridge changes. Large cartridge capacity for extended cartridge use. Unit can be wall or benchmounted. Choose from two models. D1, Single cartridge model. D2, Dual cartridge model. (Can also be used as a standalone deionizer). MEGA-PURE Deionization Cartridges Model # Type Applications Price D A Used in MP-12A and D2 (high purity) D B Used in D1 & D2 (extended capacity) D O Used in D2 for organic & chlorine removal

9 M E G A - P U R E T E S T R E S U L T S Test Results DATE 10/2/94 10/2/94 10/2/94 11/2/94 SAMPLE LOCATION TAP water Condenser Distillate Tube ACS RESISTIVITY (megohm/cm 2 ) TOC (mg/l) 1.30 < 0.05 < BACTERIA CF U/ml 24 hr hr hr ENDOTOXIN Eu/ml 7.0 average < < < CALCIUM (µg/l) (23.25 mg/l) 6.0 < 5.0 MAGNESIUM (µg/l) (75.03 mg/l) < 1.0 < 1.0 SODIUM (µg/l) (13.95 mg/l) < 5.0 < 5.0 SILVER (µg/l) < 1.0 < 1.0 COPPER (µg/l) < 1.0 < 1.0 LEAD (µg/l) < 1.0 < 1.0 NICKEL (µg/l) < 5.0 < 5.0 MANGANESE (µg/l) < 0.1 < 0.1 TIN (µg/l) < 6.0 < 6.0 CADMIUM (µg/l) < 0.2 < 0.2 CHROMIUM (µg/l) < 1.0 < 1.0 SILICA (µg/l) (12.04 mg/l) < 3.0 < 3.0 CHLORIDE (µg/l) (24.25 mg/l) < 5.0 < 5.0 AMMONIA (µg/l) < 10.0 < 10.0 FREE CHLORINE (mg/l) BDL NOTES - Test Results were based on the following information. Still Voltage: 230V Feedwater Temperature: 15.0 to 16.0 C Condenser Water to Boiler Temperature: 60.9 C Product Water Flow: 50.0 ml/min. Vent Temperature: 85.0 to 96.7 C. MEGA-PURE 3A ACS TAP feed. Tapwater: Dubuque, Iowa U.S.A. 5.0 Eu/ml positive Endotoxin control recovered 4.8 Eu/ml during assay. Positive bacterial control of 1.0 ml of a too numerous to count culture gave an approximate 60.0 CF U/ml count. If bacterial and endotoxin free, water does not inhibit bacteria or endotoxins. BDL = Below Detection Limit.

10 F I - S T R E E M I I I G L A S S S T I L L S Leave it to FI-Streem to find ways to make your job easier. This top-of-the-line glass distillation system increases efficiency by producing distilled water at the rate of 2, 4, or 8-liters per hour. The FI-Streem Glass Stills have dual feed capabilities for tap or pretreated feedwater. A patented vapor trap eliminates carry-over of contaminants in the vapor-borne water droplets. Space saving design Fully automatic microprocessor controls Automatic drain reduces frequency of cleaning FI-Streem II 2S Glass Still FI-Streem III Glass Stills FI-Streem III 4 LPH FI-Streem III 8 LPH Product Cooling Overall Dimension Weight Water Electrical Water Inches (cm) Feed Water Lbs (kg) Model # Cap (50/60 Hertz) Amps (LPH) W D H Type Operating Ship # of Heaters Price A LPH 240 V (30.5) 15 (38.1) 29.5 (74.9) tap/pretreated 65 (29.5) 55 (25) 2 A LPH 208 V (30.5) 15 (38.1) 29.5 (74.9) tap/pretreated 65 (29.5) 55 (25) 2 A LPH 240 V (48.3) 15 (38.1) 29.5 (74.9) tap/pretreated 80 (36.3) 64 (29) 4 A LPH 208 V (48.3) 15 (38.1) 29.5 (74.9) tap/pretreated 80 (36.3) 64 (29) 4 A LPH 120 V (26.6) 13.8 (35) 31.5 (79) tap/pretreated 48.5 (22) 33 (15) 2 A LPH 120 V (26.6) 13.8 (35) 31.5 (79) tap/pretreated 48.5 (22) 33 (15) 2 A LPH 220 V (26.6) 13.8 (35) 31.5 (79) tap/pretreated 48.5 (22) 33 (15) 2 BENEFITS FI-Streem II 2S Glass Still Patented vapor trap eliminates carry-over of contaminants in the vapor-borne water droplets. Easy push-button controls for automatic operation. For convenience, FI-Streem II 2S was designed with dual feed capabilities for tap or pretreat ed feedwater. Includes over temperature and low water cutoff safety device. 24 hour automatic operation when used with a A L storage reservoir. Space-saving design can be Two 120V models available: lph lph CSA and CE marked. FI-Streem III 4 Liter and 8 Liter Glass Stills Patented vapor trap eliminates carry-over of contaminants in the vapor-borne water droplets, which may contain impurities. Totally enclosed still assures your safety from breakage or hot surfaces. Glass components assure virtually no leaching of impurities into the distilled Standard Specifications Max Min Auto Stop Auto Low Water Pressure Pressure Start* Drain Cut-off 80 psig (5.6 kg/cm 2 ) 15 psig. (1.1 kg/cm 2 ) Yes Yes Yes * When connected to FI-Streem tank or using level monitor provided water. Fully automatic microprocessor controls activated by pressing button on the membrane touch pad control. Simplifies operation and cleaning, while also assuring high reliability. 24 hour automatic control activates still as required to maintain a full reservoir. Automatic drain cycle reduces frequency of cleaning. Membrane switch control is easy to operate. Thermistor and heat sensor offer double protection against low water conditions. For convenience, unit is designed with capabilities for tap or pretreated feedwater. Space-saving design - wall or bench mounted. CSA and CE marked. FI-Streem is a registered trademark of Sanyo/Gallenkamp PLC

11 B I - D I S T I L L E R You have to like a product that s so straight forward it speaks for itself. For instance, FI-Streem III 4-Liter Bi-Distiller Glass Still has a patented vapor trap that effectively eliminates carry-over of contaminants in the vapor-borne water droplets. And because we know your time is a premium, FI-Streem s thermistor and heat sensor means you won t have to babysit the unit in order to avoid low water conditions. Glass components assure virtually no leaching Fully automatic microprocessor controls Pretreatment kit reduces cleaning Pretreatment Kit FI-Streem III 4 LPH Bi-Distiller Auto Low Maximum Minimum Stop Auto Water Pressure Pressure Start* Drain Cut-off 80psig 15 psig Yes Yes Yes (5.6 kg/cm 2 ) (1.1 kg/cm 2 ) Product Cooling Overall Dimensions Weight Water Electrical Water Inches (cm) Feed Water Lbs (kg) # of Model # Cap (50/60 Hz) Amps (LPH) W D H Type Operating Shipping Heaters Price A LPH 240 V (48.3) 15 (38.1) 29.5 (74.9) tap/pretreated 80 (36.3) 64 (29) 4 A LPH 208 V (48.3) 15 (38.1) 29.5 (74.9) tap/pretreated 80 (36.3) 64 (29) 4 * When connected to FI-Streem tank or using level monitor provided. Pretreatment Kit Overall Dimensions Inlet Max Inches (cm) Connection Shipping Weight Model # Electrical Pressure (psig) W D H (Inches) Lbs (kg) Price A V / 60 Hz (27.9) 8.25 (21) 23.5 (59.7) 1/4 NPTF 10 (4.5) A V / 50 Hz (27.9) 8.25 (21) 23.5 (59.7) 1/4 NPTF 10 (4.5) D0832 Pretreatment Cartridge / Mixed Bed Recommended for use with 4 and 8 liter/hour models only. Pretreatment kit comes without the D0832 cartridge. BENEFITS Bi-Distiller Double distillation process increases water purity to above 1 megohm-cm. Patented vapor trap eliminates carry-over of vapor-borne water droplets, which may contain impurities. Glass components assure virtually no leaching of impurities into the distilled water. Fully automatic microprocessor controls activated by pressing button on the membrane touch pad control. Simplifies operation and cleaning, while also assuring high reliability. 24 hour automatic control activates still as required to maintain a full reservoir. Automatic drain cycle reduces frequency of cleaning. Membrane switch control is easy to operate. Thermistor and heat sensor offer double protection against low water conditions. For convenience, unit is designed with capabilities for tap or pretreated feedwater. Space-saving design - wall or bench mounted. CSA and CE approved. Pretreatment Kit FI-Streem deionizers are a simple pretreatment system for FI-Streem III glass stills. Pretreat feed water for a higher purity distillate, thus reducing cleaning frequency. Utilizes disposable cartridges for removal of organics and inorganic solids and gases (D0832). Visual Go/No Go indicator alerts operator when cartridge replacement is necessary.

12 F I - S T R E E M S T O R A G E T A N K S Here s a storage system with the versatility you re looking for! FI-Streem offers tanks in a variety of sizes to fit YOUR diverse laboratory requirements. Most notably, our 30-liter tank can be connected directly to the still to provide a fully automatic system supplying the highest quality distilled water. And portability? The 8 and 50-liter tanks are easily moved to other lab locations. What convenience! Choice of 4 water storage systems A Liter 24 hour automatic operation Bench or wall mounted Vent filter prevents air-borne contamination in reservoir A Liter A Storage Tank Reservoirs for use with FI-Streem III 4 and 8 liter models only** Overall Dimensions Weight Inches (cm) Lbs (kg) Model # Capacity W D H Shipping Operating Price A liters 18 (46) (37.5) 29.5 (74.9) 61.5 (28) 130 (60) A liters 14 (35.6) 14 (35.6) 32 (81.3) 11 (4.9) 121 (54.9) Reservoirs for use with FI-Streem II 2S models only* Overall Dimensions Weight Inches (cm) Lbs (kg) Model # Capacity W D H Shipping Operating Price A liters 8 (20) 6.5 (17) 17 (43) 7 (3.2) 25 (11.4) A liters 22.5 (57.2) 12 (30.5) 20 (50.8) 40 (18.1) 270 (122.7) * For use with FI-Streem II 2S only. ** For use with 4 and 8-liter/hour models only. Reservoirs for use with FI-Streem III 4 and 8-liter models only Reservoirs for use with FI-Streem II 2S models only A : 30 Liter Capacity Allows for 24 hours automatic operation. Vent filter prevents airborne contamination. Built-in overflow tubing directs water to drain in case of overflow. Contains special ports to feed deionization systems. Contains a sight tube for easy indication of water level. Easy-to-clean storage tank, wall or bench mounted. Bench or wall mounting flexibility. A1058: 50 Liter Capacity Portable unit easily moves to other lab areas needing distilled water. A1054: 30 Liter Capacity Allows for 24 hours automatic operation. Includes distillate level sensor. Built-in overflow tubing directs water to drain in case of overflow. Contains special ports to feed deionization systems. Easy-to-clean storage tank, wall or bench mounted. Optional bench mounting stand available (Part #A1057). A1052: 8 Liter Capacity Includes wall mounting bracket for easy installation. Portable size is ideal for transporting distilled water to different lab sites.

13 C L A S S I C S T I L L S Still relevant, after all these years. Our Classic Stills, designed more than a century ago, have withstood the test of time. They-re not only classic, they re durable and high quality, too. With a low water cut-off to prevent burn-out and an all-tin coating which eliminates corrosion and leaching, our Classic Stills are still the ones to use. Durable Copper and Bronze with Tin coating Capacities of.5, 1, 2, 5&10 GPH Classic Stills The Barnstead Classic Stills are designed for durability and consistent quality. The Classic Still was designed over 100 years ago, and has withstood all the tests of time. All Classic Stills incorporate a low water cut-off to prevent still burn-out in case of feedwater interruption. Classic Stills are manufactured from copper, and bronze, with a coating of pure tin. Pure tin is used due to its inert properties against the corrosive nature of pure water. Pure tin will also not leach any contaminants into the water. Common Features of Electric Classic Stills A1011, A1013, A1015, A1016 and Steam A1212, A1213 Feedwater preheated in condenser conserves energy Double-walled boiler conserves electricity Extremely inert pure tin lining prevents leaching of impurities into purified water Vented condenser allows for stripping of gaseous impurities Unique deconcentrator removes scale forming impurities Q-Baffle insures high quality pyrogen free product water Bench, floor, or wall mounted Metal construction withstands years of use Specific Features of A1011, A1013, A1015, A1016 Electric Stills Operates on a wide variety of electrical services Capacities range from 1, 2, 5 & 10 gallons per hour Many options are available which include fully automatic controls Includes low water cut-off to protect heating elements from burn-out when water supply is interrupted. All stills require 2 separate input power supplies: - 120V supply for low water cut-off - power supply for contactor and heating elements Specific Features of A1007 Economical Electrical Portable Stills Produces high quality distilled water at the rate of 1/2 GPH (1.9 lph) Ideal for educational and other labs with moderate pure water requirements Requires no permanent plumbing or electrical connections, and can be set up for operation in minutes Includes low water cut-off safety protection Specific features of A1212, A1213 Steam Stills Utilizes available steam as heat source 5 & 10 GPH sizes available

14 C L A S S I C S T I L L S S P E C I F I C A T I O N S Electric Stills Pretreated Cooling Water Dimensions Shipping Cooling Feed Waste Amps GPH (lph) WxDxH Weight Model # Water Fitting Water (1) Water KW Volts/Phase Requirements Mounting (cm) Lbs(kg) Price A " NPT NA 1 2" NPT amps 4 Bench 21"x10"x19" (53x26x49) 25 (11.4) 1 2 GPH (.64 cm) (1.3 cm) 120V (15) (1.9 lph) 1 phase A1011-A 1 4" NPT 3 8" NPT 1 2" NPT amps 8 Bench 22"x10"x20" (55.9x25.4x73.7) 30 (13.6) 1 GPH (.64 cm) (1 cm) (1.3 cm) 120V (30.28) Wall 22"x13"x38" (55.9x33.0x96.5) 55 (25) (3.8 lph) 1 phase Floor 22"x10"x66" (55.9x25.4x167.6) 70 (31.8) A1011-B 1 4" NPT 3 8" NPT 1 2" NPT amps 8 Bench 22"x10"x20" (55.9x25.4x73.7) 30 (13.6) 1 GPH (.64 cm) (1 cm) (1.3 cm) 240V (30.28) Wall 22"x13"x38" (55.9x33.0x96.5) 55 (25) (3.8 lph) 1 phase Floor 22"x10"x66" (55.9x25.4x167.6) 70 (31.8) A1013-B 1 4" NPT 3 8" NPT 1 2" NPT 6 26 amps 16 Bench 23"x11"x35" (58.4x27.9x88.9) 40 (18) 2 GPH (.64 cm) (1 cm) (1.3 cm) 240V (60.56) Wall 23"x14"x44" (58.4x35.6x111.8) (7.6 lph) 1 phase Floor 23"x11"x68" (58.4x27.9x172.7) 100 (45.4) A1013-C 1 4" NPT 3 8" NPT 1 2" NPT 6 17 amps 16 Bench 23"x11"x35" (58.4x27.9x88.9) 40 (18) 2 GPH (.64 cm) (1 cm) (1.3 cm) 208V (60.56) Wall 23"x14"x44" (58.4x35.6x111.8) 65 (29.5) (7.6 lph) 3 phase Floor 23"x11"x68" (58.4x27.9x172.7) 100 (45.4) A1015-B 1 4" NPT 3 8" NPT 3 4" NPT amps 40 Bench 35"x14"x45" (88.9x35.6x114.3) 90 (40.8) 5 GPH (.64 cm) (1 cm) (1.9 cm) 240V (151.40) Wall 35"x18"x54" (88.9x45.7x137.2) (19 lph) 1 phase Floor 35"x14"x77" (88.9x35.6x195.6) 150 (68.0) A1015-C 1 4" NPT 3 8" NPT 3 4" NPT amps 40 Bench 35"x14"x45" (88.9x35.6x114.3) 90 (40.8) 5 GPH (.64 cm) (1 cm) (1.9 cm) 208V (151.40) Wall 35"x18"x54" (88.9x45.7x137.2) 125 (56.7) (19 lph) 3 phase Floor 35"x14"x77" (88.9x35.6x195.6) 150 (68.0) A1015-D 1 4" NPT 3 8" NPT 3 4" NPT amps 40 Bench 35"x14"x45" (88.9x35.6x114.3) 90 (40.8) 5 GPH (.64 cm) (1 cm) (1.9 cm) 240V (151.40) Wall 35"x18"x54" (88.9x45.7x137.2) 125 (56.7) (19 lph) 3 phase Floor 35"x14"x77" (88.9x35.6x195.6) 150 (68.0) A1016-X003 1/4" NPT 3 8" NPT 3 4" NPT amps 80 Bench 43"x14"x58" (109.2x35.6x147.3) 310 (140.6) 10 GPH (.64 cm) (1 cm) (1.9 cm) 208V (302.80) Wall 36"x20"x73" (91.4x50.8x185.4) 330 (149.7) (38 lph) 3 phase Floor 37"x14"x89" (94x35.6x226.1) 360 (163.3) A1016-D 1/4" NPT 3 8" NPT 3 4" NPT amps 80 Bench 43"x14"x58" (109.2x35.6x147.3) 310 (40.6) 10 GPH (.64 cm) (1 cm) (1.9 cm) 240V (302.80) Wall 36"x20"x73" (91.4x50.8x185.4) 330 (149.7) (38 lph) 3 phase Floor 37"x14"x89" (94x35.6x226.1) 360 (163.3) A1016-F 1/4" NPT 3 8" NPT 3 4" NPT amps 80 Bench 43"x14"x58" (109.2x35.6x147.3) 310 (140.6) 10 GPH (.64 cm) (1 cm) (1.9 cm) 480V (302.80) Wall 36"x20"x73" (91.4x50.8x185.4) 330 (149.7) (38 lph) 3 phase Floor 37"x14"x89" (94x35.6x226.1) 360 (163.3) * Inlet water pressure psi ( kg/cm 2 ) Steam Stills Steam Steam Cooling Shipping Cooling Feed Steam Steam Waste (2) Pressure Boiler Consumed Water Dimensions Weight Model # Water Water Inlet Return (3) Outlet GPH (lph) Horsepower lbs/hr (kgs/hr) GPH (lph) Mounting WxDxH Lbs. (kg) Price A " NPT 3 8" NPT 3 8" NPT 3 8" NPT 3 4" NPT PSI (20.4) 40 (151.40) Bench 31"x18"x43" 80 5 GPH (.64 cm) (1 cm) (1 cm) (1 cm) (1.9 cm) (78.7 X 45.7 X 109.2) (36.3) (19 lph) 5 GPH Wall 31"x21"x51" 110 (19 lph) (78.7x53.3x129.5) (49.9) Floor 31"x18"x75" 135 (78.7x45.7x190.5) (61.3) A " NPT 3 8" NPT 3 4" NPT 1 2" NPT 3 4" NPT PSI (40.8) 80 (302.80) Bench 35"x19"x58" GPH (1 cm) (1 cm) (1.9 cm) (1.3 cm) (1.9 cm) (88.9x48.3x147.3) (132) (38 lph) 10 GPH Wall 35"x22"x70" 310 (38 lph) (88.9x55.9x177.8) (140.6) Floor 35"x19"x90" 330 (88.9x48.3x228.6) (149.7) 1. For pretreated water stills only. 2. Connect to atmospherically vented drain. 3. Not included with condensate feed stills.

15 C L A S S I C S T I L L A C C E S S O R I E S FULLY AUTOMATIC CONTROLS Stops still when storage tank is full. Starts still when storage tank water level falls below preset level. Drains still boiler at 2, 4, 8, or 16 hr. intervals to reduce scale formation. The Controls include: control box, storage tank monitor, Inlet includes: piping, solenoid valve, pressure gauge, manual regulating valve. Boiler drain includes: piping, solenoid valve, manual valve. Model # Voltage Where used Price G V 50/60 hz 1 & 2 gph 1 phase electric stills G V 50/60 hz 2 gph 3 phase electric stills G V 50/60 hz 5 gph electric stills, 1 & 3 phase G V 50/60 hz 10 gph 1 phase electric stills G V 50/60 hz 10 gph 3 phase electric stills G V 50/60 hz 5 gph steam stills G V 50/60 hz 10 gph steam stills NOTE: Fully Automatic Control is connected to the 120/240V Low Water Cutoff control box. 240V Low Water Cutoff is fitted with a stepdown transformer to 120V. 120V Fully Automatic Control may be connected to any Low Water Cutoff. CARTRIDGE PRETREATMENT KIT FOR CLASSIC STILLS Reduces scale-forming impurities in boiler feedwater. Improves product water purity. Decreases the need for frequent boiler cleaning. Improves heating element efficiency. The Kit includes a cartridge with ion exchange resin to remove scaleforming impurities and activated carbon to remove chlorine and volatile organics. Also included is a cartridge holder for wall mounting, a flow regulator, and tubing for connection to a 1 or 2 GPH Classic Still. Note: This kit can only be used on 1 and 2 GPH Classic Stills. Model No. Description Price G3628 Cartridge Pretreatment Kit for 1 and 2 GPH Stills (Includes one cartridge) D8921 Extra Pretreatment Cartridge FLOAT FEEDER FOR CLASSIC STILLS Pretreated water conservation. Float mechanism controls the flow of pretreated water to boiler. All surfaces coming in contact with purified water are pure tin. Used only on 5 and 10 gph classic stills. Must be used with automatic feedwater solenoid valve and fully automated controls on 5 & 10 GPH. Model No. Price G3721 Electric still with automatic controls mounted on floorstand. Pretreated Cartridge Kit for 1 & 2 gallon electric stills. Shown with automatic controls mounted on wall bracket.

16 C L A S S I C S T I L L A C C E S S O R I E S Puromatic Diverter for Classic Stills G3330 Allows you to set minimum distilled water resistivity. Diverts substandard distilled water to drain. All piping constructed of inert pure tin. Automatic temperature compensated purity meter. Model No. Power Price G VAC- 50/60 Hz Automatic Feedwater Shut-off Valve for Classic Stills G2910 Must be used with float feeder and fully automatic control on 5 & 10 GPH classic stills using pretreated feedwater. Conservation of water and automatic operation. To be used with float feeder (G3721) to start or stop feedwater. Note: This accessory can only be used on 5 and 10 gph classic stills. Floorstand for Classic Stills G1000, G1001 Available for all classic stills, 1 to 10 GPH. The floorstands are crafted of sheet metal and are provided with adjustable feet. Dimensions Shipping Model No. Description WxDxH Weight Price G1000 Floorstand for 5 and 10 GPH 19.75" x 9.5" x 35" 40 lbs Electric & Steam Stills (50.2 x 24.1 x 88.9) (18.2 kg) G1001 Floorstand for 1 and 2 GPH 10.38" x 7" x 36" 25 lbs Electric Stills (26.4 x 11.8 x 91.4) (11.4 kg) Wall Bracket for Classic Stills G3250, G3251, G3252, G3256, G3275 Available for all classic stills, 1 to 10 GPH. The wall brackets are made of aluminum casting (G3275 made of steel). Model No. G2910 Price Model No. Description Price G3250 Wall Bracket for all 1 GPH Electric Stills G3251 Wall Bracket for 2 GPH Electric Still G3252 Wall Bracket for 5 GPH Electric Still G3256 Wall Bracket for 5 GPH Steam Still G3275 Wall Bracket for 10 GPH Electric and Steam Stills Electric still with automatic controls, Puramatic Diverter, Float Feeder and automatic feedwater shut-off valve. Mounted on floorstand. Steam still with automatic controls on floorstand connected to storage tank.

17 C L A S S I C S T I L L S S T O R A G E T A N K S / A C C E S S O R I E S The Barnstead tin-lined tanks are the ideal complement to the Classic Still. These tanks range in storage capacity from gallons. All tanks are skillfully crafted from copper and hand-wiped with pure tin to protect the purity of the distilled water. Cylindrical Storage Tanks All tanks include with removable cover, water level sight glass, and a tin coated draw off faucet with serrated hose nipple. Multiple connections provided for various accessories - See drawing for different connection option. Connections are provided for: Water inlet, distribution outlet, tank drain (not on 10 and 25 gallon) Connections are also provided for optional accessories: Pump, low water cut-off, pump by-pass return, still level control, ultraviolet lamp, Ventgard and water seal. Connections not used are provided with removable plugs. Rectangular Storage Tanks Provides maximum purity protection with a minimum of space required Available in two sizes and are designed for wall-mounting Constructed of copper with enameled finish outside, double hot-wiped tin inside; skillfully crafted from copper and handwiped with tin to protect the purity of distilled water Included with the tank are an ultraviolet lamp assembly, Ventgard and water seal, selfclosing faucet with serrated hose nipple, sight glass, and wall bracket Ventgard Air Filter Additional standard connections (plugged if not used) are for: high level monitor for automatic controls, low level monitor (pump low-water cut-off), drain and pump outlet and by-pass return. NOTE: Rectangular tinned tanks are provided with one Ventgard and a water seal for 1 to 10 GPH input. If draw-off rate exceeds 15 lpm (4 GPM), order an additional Ventgard Air Filter. Ventgard Air Filter and Water Seal Ventgard Air Filter protects the stored distilled water against airborne impurities Water Seal works as a one-way valve to allow distilled water into storage tank. It prevents air from entering the storage tanks via the condenser atmospheric vent. Tin-Coated Cylindrical Storage Tanks Pump Shipping Size Dimensions Dist. By-Pass Weight Model # Gallon WxDxH (cm) Outlet Return Drain Lb (kg) Price B "x10.25"x 29" 1 2" NPT 1 4" NPT 25 lbs. (43.2x26.1x73.7) (.64 cm) (11.3 kg) B "x 18"x 29" 1 2" NPT 1 4 NPT 45 lbs. (63.5x45.7x73.7) (.64 cm) (20.4 kg) B "x 21.78"x36" 1" NPT 1 4 NPT 1 2" NPT 195 lbs. (71.1x55.3x91.4) (.64 cm) (1.3 cm) (88.5 kg) B "x 28.5''x43.125" 1" NPT 1 4 NPT 1 2" NPT 420 lbs. (88.9x72.4x109.5) (.64 cm) (1.3 cm) (190.5 kg) B "x 37.9"x50.25" 1" NPT 1 4 NPT 1" NPT 400 lbs. (114.3x96.3x127.6) (.64 cm) (2.5 cm) (181.4 kg) Tin-Coated Rectangular Storage Tanks Dimensions Pump Shipping Model # Size WxDxH (cm) Outlet Weight - Lb (kg) Price B gallon 37"x 21"x 31" 1 2" NPT 150 lbs. (93.9x53.3x78.7) (1.3 cm) (68 kg) B gallon 37"x 26" x36" 3 4 NPT 200 lbs. (93.9x66.0x91.4) (1.9 cm) (90.7 kg) Ventgard Air Filter Model # Description Price H3111 H3120 H3130 Ventgard and 1 to 10 gph water seal Ventgard air filter Water seal 1 to 10 gph Replacement filter element Tin-Coated Cylindrical Storage Tanks

18 C L A S S I C S T I L L S S T O R A G E T A N K S / A C C E S S O R I E S Floor Stands for Gallon Cylindrical Storage Tanks Floor stands for gallon storage tanks are fabricated of from heavy gauge sheet metal and are provided with adjustable feet. Floor stands for gallon storage tanks are fabricated of thick steel angle-iron. Wall Bracket for Cylindrical Storage Tanks Wall brackets for 10 gallon tanks are fabricated from heavy gauge aluminum. Wall brackets for 25 gallon tanks are fabricated of thick steel angleiron. Ultraviolet Lamp Assembly The ultraviolet lamp is designed to be installed on a storage tank to maintain the sterility of the distilled water in storage. The ultraviolet assembly consists of a cylindrical electrical housing which includes a starter, ON/OFF switch, 6 foot electrical cord, lamp and ballast. The housing is designed to be mounted on top of a storage tank with the lamp extended vertically into the tank. The lamp is enclosed by a tubular, transparent, inert sheath. The sheath is sealed at the neck by a grommet installed on top of the storage tank. When it is necessary to change the lamp, only the lamp need be removed. The reservoir cover and sheath remain in place at all times so distilled water is never exposed to possible contamination from the air. The ultraviolet lamp operates from 120 VAC, 50/60 Hz, 35 Watt electrical power. NOTE: Each ultraviolet lamp assembly is furnished with one bulb which should be replaced every 90 days if operated continuously. Rectangular tanks are always provided with Ultraviolet Assembly. Floor Stand for Cylindrical Storage Tank Floor Stands for Cylindrical Storage Tanks Overall Dimensions Size of tanks W x D x H Model # to be held Inches (cm) Price H gallon 8 x 8 x 26 (51 x 51 x 168) H gallon 13 x 13 x 26 (84 x 84 x 168) H gallon 16 x 16 x 20 (104 x 104 x 130) H & 150 gallon 20 x 20 x 11 (130 x 130 x 71) H gallon 27 x 27 x 20 (175 x 175 x 130) Wall Brackets for Cylindrical Storage Tanks Size of tank Model # to be held Price H3240 H gallon 25 gallon Ultraviolet Lamp Assembly Model # Description Price H4005 UV Lamp Assembly and Lamp Wall Bracket for Cylindrical Storage Tank Replacement Ultraviolet Lamp for 120V operation

19 C A B I N E T I Z E D S T I L L S We ve got pure water all locked up with our cabinetized stills. These complete water distillation and storage systems produce and store biologically pure water (meeting ASTM Type II standards) for easy, fully automatic use and installation by lab personnel. What s more, these stills allow for hands-free operation and take up less lab space than conventional units. Completely cabinetized distillation system Choose from two sizes BENEFITS Choose from two sizes. Completely cabinetized: Includes a still and an appropriately matched tin-coated storage tank in a neat, compact and clean, unit. Space saving design takes up less space than conventional units, while allowing for point of use installation. Fully Automatic: Hands-free Model 210 Still Drain (WA) Water Shipping Dimensions Model # Electrical Phase Connection Inlet Amps Weight WxDxH (cm) Price A1065-B 230 Volt " 1 2" NPT lbs. 24"x151 4"x41" 2 wire (75 kg) (60x39x102.5) A1065-C 208 Volt " 1 2" NPT lbs. 24"x151 4"x41" 4 wire (75 kg) (60x39x102.5) A1065-D 240 Volt " 1 2" NPT lbs. 24"x151 4"x41" 3 wire (75 kg) (60x39x102.5) A1065-F 460 Volt " 1 2" NPT lbs. 24"x151 4"x41" 3 wire (75 kg) (60x39x102.5) A1066 Optional Floor Stand Model 525 Still 210 Cabinetized Still (cover off) 525 Cabinetized Still operation; turns still off when the tank is full, restarts still when tank empties. Automatically drains the boiling chamber every time the unit is off and every 4 hours of operation, helping to keep your still clean. Model 210 Still Safety feature: interrupts power to heating elements if feed water is off. Optional bench stand for bench mounting of still. 2 GPH still and 10 gallon storage tank for the production of distilled water. Model 525 Still Purity meter alerts you of distilled water purity in storage tank. Q-Baffle allows for pyrogen removal. Model No. Feedwater Electrical Phase Amps Water Inlet (CW) Drain Connector (WA) Shipping Weight Dimensions Price W x D x H (cm) A1085-B Tap 240 Volt " 1 3 8" 425 lbs "x18 3 4"x48" (193 kg) (91.4x47.6x121.9) A1085-C Tap 208 Volt " 1 3 8" 425 lbs "x18 3 4"x48" 4 wire (193 kg) (91.4x47.6x121.9) A1085-D Tap 240 Volt " 1 3 8" 425 lbs "x18 3 4"x48" (193 kg) (91.4x47.6x121.9) Optional Accessories for Model 525 Biopure Optional recirculation pump and base mounting stand available. Storage tank is equipped with a UV lamp for bacterial control. 5 GPH still and 25 gallon storage tank for production of distilled water. A1521 A1522 Floorstand 36"x18 3/4"x35" (91.4x47.6x89 cm) Recirculating Pump (Includes A1521 floorstand) Note: Controls for all models require separate 120 volts.

DISTILLATION. The Best Distillation Times Two! 4 FI-STREEM Tap/Pretreated 30 Liter Storage Reservoir WP54 50 Liter Storage Reservoir

DISTILLATION. The Best Distillation Times Two! 4 FI-STREEM Tap/Pretreated 30 Liter Storage Reservoir WP54 50 Liter Storage Reservoir Selection Guide GLASS STILLS ELECTRIC CLASSIC STILLS Product Output Feed Water Reservoir GPH Type Options Page Our Only Portable Still! 0.5 Tap* 10 Gallon Tin WP56 Coated Cylindrical Tanks Classic, Time-Tested

More information

Water Purification 85

Water Purification 85 Water Purification 85 Distillation Distillation is a natural process that has been used to purify liquids for many hundreds of years. Today it remains the most commonly used technique for water purification

More information

Water Purification. Quality distilled... the most reliable method of purifying water 81

Water Purification. Quality distilled... the most reliable method of purifying water 81 Water Purification Quality distilled... the most reliable method of purifying water 81 Distillation Distillation is a natural process that has been used to purify liquids for many hundreds of years. Today

More information

Classic Electrically Heated Stills

Classic Electrically Heated Stills Classic Electrically Heated Stills OPERATION MANUAL AND PARTS LIST SERIES 2112 Model Numbers A1011 A1015 A1013 A1016 With and Without FAC Controls LT2112X1 10/20/09 1 Table of Contents Safety Information...3

More information

MINI-CLASSIC II. Portable Distiller

MINI-CLASSIC II. Portable Distiller MINI-CLASSIC II Portable Distiller The Pure Water, Inc. Mini-Classic II is a compact, portable distiller with a removable boiling chamber allowing for easy filling and cleaning. With a capacity of approximately

More information

Fountain Classic. Installation and Owner s Manual. Page 16

Fountain Classic. Installation and Owner s Manual. Page 16 Fountain Classic Installation and Owner s Manual Page 16 4120 NW 44th St Lincoln, NE 68524 USA Tel: 402.467.9300 Toll Free in the USA: 800.875.5915 Fax: 402.467.9393 www.purewaterinc.com Page 2 Fountain

More information

EASYpure RODI. OPERATION MANUAL AND PARTS LIST Series Model D Volts LT1332X1 6/1/04

EASYpure RODI. OPERATION MANUAL AND PARTS LIST Series Model D Volts LT1332X1 6/1/04 EASYpure RODI OPERATION MANUAL AND PARTS LIST Series 1332 Model D13321 100-240 Volts LT1332X1 6/1/04 Table of Contents Safety Information...4 Alert Signals...4 Warnings...4 Introduction...6 Product Overview...6

More information

ULTIMA 888 Installation Manual

ULTIMA 888 Installation Manual ULTIMA 888 Installation Manual For models produced after September 1, 1998 TABLE OF CONTENTS Important Safety Information...3 For the Record...3 ULTIMA 888 Specifications...3 Operating Parameters...4 Suitable

More information

DEAERATORS .005 ATMOSPHERIC DEAERATOR

DEAERATORS .005 ATMOSPHERIC DEAERATOR 918 W WALNUT ST, DANVILLE, KENTUCKY 40422-0048 PHONE (859) 236-3181 www.sellersmfg.com SPECIFICATION SHEET NO. 3300 DEAERATORS.005 ATMOSPHERIC DEAERATOR GENERAL DESCRIPTION The Sellers atmospheric.005

More information

Packaged Steam Fired Water Heater

Packaged Steam Fired Water Heater MODEL ST Packaged Steam Fired Water Heater Utilizes Steam To Heat Domestic Water, Semi-Instantaneous or Storage Type Heaters Features Reliable Packaged System Only high grade materials used in construction

More information

.005 ATMOSPHERIC DEAERATOR

.005 ATMOSPHERIC DEAERATOR .005 ATMOSPHERIC DEAERATOR OCTOBER 1, 2007 GENERAL DESCRIPTION The Sellers atmospheric.005 deaerators condition make-up water and condensate returns to convert them into more desirable boiler feedwater.

More information

.03 ATMOSPHERIC DEAERATOR

.03 ATMOSPHERIC DEAERATOR .03 ATMOSPHERIC DEAERATOR SPECIFICATION SHEET NO. 3200 OCTOBER 1, 2007 GENERAL DESCRIPTION The Sellers atmospheric.03 deaerators condition make-up water and condensate returns to convert them into more

More information

Aries - Operation & Maintenance Manual Lab Water Purification System

Aries - Operation & Maintenance Manual Lab Water Purification System Aries - Operation & Maintenance Manual Lab Water Purification System M-0309201102 Revision 6 Thank you for purchasing the ARIES High Purity Water System. For optimum performance and safety please read

More information

ASME Packaged Electric Water Heater

ASME Packaged Electric Water Heater MODEL SH & H ASME Packaged Electric Water Heater 15-1600 KW - All Voltages & Phases, 80-5000 Gallon Capacity Features Reliable Packaged System Only high grade materials used in construction to ensure long

More information

MEGA-PURE 6A Water Still

MEGA-PURE 6A Water Still MEGA-PURE 6A Water Still OPERATION MANUAL AND PARTS LIST Series 676 Model# A440697 A440518 Voltage 208V 240V 927541 1/9/03 1 Table of Contents General Information... 3 Safety Information... 3 Alert Signals...

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining provides superior protection and tank longevity Heavy duty construction withstands

More information

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR SPECIFICATIONS MODEL E859C MINI DEHYDRATOR 1 DEHYDRATION TECHNOLOGY This proposal describes the equipment which shall be supplied by ENERVAC for a system for processing (dehydrating, de-aerating, purifying

More information

Taco 00 Series Cartridge Circulators

Taco 00 Series Cartridge Circulators Water Circulation Pumps & Circulators Taco 00 Series Cartridge Circulators For over 70 years, Taco has led the industry with the highest quality circulators you can buy. Designed for a wide range of residential

More information

Pure Water C-630 Commercial Distillation System

Pure Water C-630 Commercial Distillation System Pure Water C-630 Commercial Distillation System OWNERS MANUAL Published by: The Commercial Products Division Pure Water 4120 NW 44th Lincoln, Nebraska 68524 U.S.A. Telephone (402) 467-9300 Fax (402) 467-9393

More information

FlaskScrubber & SteamScrubber. Laboratory Glassware Washers NEW! FlaskScrubber & SteamScrubber racks now interchangeable

FlaskScrubber & SteamScrubber. Laboratory Glassware Washers NEW! FlaskScrubber & SteamScrubber racks now interchangeable FlaskScrubber & SteamScrubber Laboratory Glassware Washers! FlaskScrubber & SteamScrubber racks now interchangeable FlaskScrubber Laboratory Glassware Washers General Features Patent-pending design Lower

More information

Packaged Semi-Instantaneous Steam Fired Water Heater

Packaged Semi-Instantaneous Steam Fired Water Heater MODEL STX Packaged Semi-Instantaneous Steam Fired Water Heater Shell and Tube Style Heater Features Reliable Only high grade materials used in construction to ensure long operating life Heat exchange pressure

More information

Standard Features. Performance/Capacities

Standard Features. Performance/Capacities TSC-66 Traditional Power/Connections Approximate Total Load AMPS 208V / 60HZ / 3PH 51.8 208V / 60HZ / 1PH 88.3 230V / 60HZ / 3PH 47.8 230V / 60HZ / 1PH 81.5 460V / 60HZ / 3PH 23.9 Booster Heater Options

More information

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator Wallace & Tiernan Gas Feed Systems V2000 Chlorinator Introduction Siemens Water Technologies chlorination equipment has the benefit of 100 years of experience in gas feed technology. V2000 chlorinators

More information

EASYpure RF. Series 1051 OPERATION MANUAL AND PARTS LIST BARNSTEAD THERMOLYNE CORPORATION

EASYpure RF. Series 1051 OPERATION MANUAL AND PARTS LIST BARNSTEAD THERMOLYNE CORPORATION BARNSTEAD THERMOLYNE CORPORATION EASYpure RF OPERATION MANUAL AND PARTS LIST Series 1051 Model D7032 Model D7031 Model D7033 Model D7033-33 100 Volts 120 Volts 240 Volts 230 Volts LT1051X1 8/22/97 1 Table

More information

BARNSTEAD THERMOLYNE CORPORATION. NANOpure Infinity UF OPERATING MANUAL AND PARTS LIST. Series 898 D D LT898X1 5/11/98

BARNSTEAD THERMOLYNE CORPORATION. NANOpure Infinity UF OPERATING MANUAL AND PARTS LIST. Series 898 D D LT898X1 5/11/98 BARNSTEAD THERMOLYNE CORPORATION NANOpure Infinity UF OPERATING MANUAL AND PARTS LIST Series 898 Model # Voltage D8981 120 D8982-33 230 LT898X1 5/11/98 Serial Number 1 Table of Contents Safety Information...

More information

"ESDDR" Series Electric Humidifier

ESDDR Series Electric Humidifier ESDDR-1 Deionized, Demineralized, or Reverse Osmosis Water "ESDDR" Series Electric Humidifier The Electric Humidifier from PURE Humidifier Co. is loaded with features and options. All you need is deionized,

More information

Technical Specifications & Pricing

Technical Specifications & Pricing Nu/Clean Model 510 Recirculating Water Deionizer Inline Aqueous Cleaning System for Closed Loop, Zero Discharge Operations Technical Specifications & Pricing The base machine in its standard configuration

More information

"ER" Series Electric Humidifier

ER Series Electric Humidifier ER-1 Standard Water "ER" Series Electric Humidifier The Electric Humidifier from PURE Humidifier Co. is loaded with features and options. All you need is tap water, electricity, and a sanitary drain the

More information

High Capacity Instantaneous Steam Fired Water Heater

High Capacity Instantaneous Steam Fired Water Heater MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and

More information

SENTRA Series Water Unit

SENTRA Series Water Unit SENTRA Series Water Unit Standard Unit: F to 0 F Process Fluid Temperatures* Optional High Temperature Configuration to 0 F Direct Injection Cooling 0 to kw Heaters to 7. HP Centrifugal Pumps (0-00 GPM)

More information

Classical and Rapid Kjeldahl Systems and Fat and Crude Fiber Apparatus

Classical and Rapid Kjeldahl Systems and Fat and Crude Fiber Apparatus Classical and Rapid Kjeldahl Systems and Fat and Crude Fiber Apparatus How to Use This Catalog This catalog contains complete information on Classical and Rapid Kjeldahl Systems, Fat Extractors and Crude

More information

Direct-Q 3, 5, 8 system Direct-Q 3 UV, 5 UV, 8 UV system User manual

Direct-Q 3, 5, 8 system Direct-Q 3 UV, 5 UV, 8 UV system User manual Direct-Q 3, 5, 8 system Direct-Q 3 UV, 5 UV, 8 UV system User manual Notice The information in this document is subject to change without notice and should not be construed as a commitment by Millipore

More information

C44A/C44AW DISHWASHER

C44A/C44AW DISHWASHER Item # Quantity C.S.I. Section 11400 C44A/C44AW DISHWASHER STANDARD FEATURES 202 racks per hour C44A 126 racks per hour C44AW Opti-RinSe system Ball detent clutch conveyor drive mechanism Top mounted controls

More information

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI Vent-Rite BULLETIN VCRV AUGUST 0 GUARDIAN Plus Cast Iron And Steel Receivers Simplex, Duplex, Triplex And Quadruplex Units Pump Capacities To 0 GPM Discharge Pressure To 7 PSI 87 Dewey Avenue Benton Harbor,

More information

60 Liter Infinity Storage Reservoir

60 Liter Infinity Storage Reservoir BARNSTEAD THERMOLYNE CORPORATION 60 Liter Infinity Storage Reservoir OPERATION MANUAL AND PARTS LIST Series 902 Model D9021 LT902X1 7/30/97 Serial Number 1 Table of Contents Safety Information... 3 Warnings...

More information

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST Item # Quantity C.S.I. Section 11400 DISHWASHER STANDARD FEATURES 244 racks per hour Opti-RinSe system Ball detent clutch conveyor drive mechanism Top mounted controls Stainless steel anti-clogging wash

More information

Water Stills. The result of decades of experience and technical innovation: four individually applicable product ranges with 14 different models.

Water Stills. The result of decades of experience and technical innovation: four individually applicable product ranges with 14 different models. Water Stills The result of decades of experience and technical innovation: four individually applicable product ranges with 14 different models. Quality built on Tradition Users in research labs, standard

More information

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER Compact Design High Recovery Energy Efficient Stainless Alloy Construction Factory Packaged Integral Safety System ASME Constructed & Stamped

More information

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge ENSPECO Recovery/ Recycle/ Evacuate/ Recharge RMS 3012 RMS 3034 Approved by UL/SAE to J-1991 R12 Purity Standards Approved by UL/SAE to J-2210 R134 Purity Standards This semi-automatic machine will recover

More information

Centro-Matic Automated Lubrication Systems System Controls

Centro-Matic Automated Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

The result of decades of experience and technical innovation: four individually applicable product ranges with 14 different models.

The result of decades of experience and technical innovation: four individually applicable product ranges with 14 different models. Water Stills The result of decades of experience and technical innovation: four individually applicable product ranges with 14 different models. 71 Quality built on Tradition Users in research labs, standard

More information

Freeze Dry Systems and Accessories

Freeze Dry Systems and Accessories Freeze Dry Systems and Accessories FreeZone Freeze Dry Systems a n o v e r v i e w Table of Contents: Overview................................... 1 Selection Guide.............................. 4 FreeZone

More information

Customized Drinking Water

Customized Drinking Water Customized Drinking Water PURA Ultraviolet Disinfection Systems 55 PURA Gen 5 Residential Systems: Genesis H2O: Ultraviolet Disinfection System A Security System For Your Water UV technology provides additional

More information

Freeze Dry Systems and Accessories

Freeze Dry Systems and Accessories Freeze Dry Systems and Accessories Freeze Dry Systems AN OVERVIEW Table of Contents: Overview................................... 1 Selection Guide.............................. 4 FreeZone Freeze Dry Systems

More information

Storage Tanks and Accessories

Storage Tanks and Accessories Storage Tanks and Accessories Storage with a Difference Guarantee the purity of your stored water Pure water requires a storage system to prevent the degradation of your water quality. EMD Millipore s

More information

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION EHB Series STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal STONESTEEL is a registered trademark of Cemline Corporation CEMLINE CORPORATION P.O. BOX 55

More information

CL64T INDUSTRIAL TOTE WASHER

CL64T INDUSTRIAL TOTE WASHER Item # Quantity C.S.I. Section 11400 STANDARD FEATURES Selectable Speed 4, 5, 6 feet/minute Opti-RinSe system Rapid return conveyor drive mechanism Insulated hinged double doors with door interlock switches

More information

EASYpure RO Reverse Osmosis System

EASYpure RO Reverse Osmosis System BARNSTEAD THERMOLYNE CORPORATION EASYpure RO Reverse Osmosis System SERIES 742 INSTALLATION, OPERATION, SERVICE AND REPAIR MANUAL, AND PARTS LIST Model Voltage D7421 120 D7422 240 D7422-33 230 D7423 100

More information

BOTTLED WATER DISPENSER DISPENSADOR DE AGUA EMBOTELLADA

BOTTLED WATER DISPENSER DISPENSADOR DE AGUA EMBOTELLADA BOTTLED WATER DISPENSER DISPENSADOR DE AGUA EMBOTELLADA Line to Refrigerator Ice/Water Dispenser Pump Module Dispenser www.xylemflowcontrol.com Flojet is a trademark of Xylem Inc. or one of its subsidiaries.

More information

ACE. HydroStream Model HC-100. Evaporative Humidification (100 lbs/hr) Produces Already Humidified Air Information Specifications...

ACE. HydroStream Model HC-100. Evaporative Humidification (100 lbs/hr) Produces Already Humidified Air Information Specifications... AC E Air Cleaning Equipment Inc 303 N Main St Broadway NC 27505 800-962-0650 www.industrialairtreatment.com Evaporative Humidification (100 lbs/hr) Produces Already Humidified Air Information Specifications...

More information

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL 6/30/06 www.electrotechsystems.com TABLE OF CONTENTS 1.0 General Page 01 2.0 Description 01 3.0 Set-Up 01 4.0 Model 5462 03 4.2

More information

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models) Temperature Control Units Water & Oil - 00 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons

More information

Large Direct-Pure EDI Water System. User Manual. RephiLe Bioscience, Ltd.

Large Direct-Pure EDI Water System. User Manual. RephiLe Bioscience, Ltd. Large Direct-Pure EDI Water System User Manual RephiLe Bioscience, Ltd. Table of Contents 1 Introduction 1.1 Product Features........5 1.2 Main Applications....6 1.3 Specifications...7 1.4 Operation......

More information

BuildingName The Description of the Project P DOCUMENTS

BuildingName The Description of the Project P DOCUMENTS ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

WATT R TWIN Energy-Efficient Home Water System

WATT R TWIN Energy-Efficient Home Water System WATT R TWIN Energy-Efficient Home Water System Owner and Installation Manual 3725 Touzalin Avenue Lincoln, NE 68507 USA Tel: 402.467.9300 Toll Free in the USA: 800.875.5915 Fax: 402.467.9393 www.purewaterinc.com

More information

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features Electric Pumps Introduction W4100, W4200 & W4300 Condensate Pumps Watson McDaniel s Condensate Return and Boiler Feed Pumps are equipped with Cast Iron bodies and Bronze Impellers. The pump receiver tanks

More information

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1.

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1. SECTION 11600 - LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION A. Laboratory Glassware Washer/Dryer 1.02 SUBMITTALS A. Bill of Materials B. Product Literature C. Installation

More information

Conveyor. AJ-44 Vision Series. Standard Features. Power/Connections. Performance/Capacities

Conveyor. AJ-44 Vision Series. Standard Features. Power/Connections. Performance/Capacities AJ-44 Vision Series Standard Features Power/Connections Approximate Total Load AMPS 208V / 60HZ / 3PH 48.4 208V / 60HZ / 1PH 82.3 230V / 60HZ / 3PH 44.4 230V / 60HZ / 1PH 75.5 460V / 60HZ / 3PH 22. 2 Booster

More information

INDUSTRIAL GRADE WATER SOFTENERS LWT INDUSTRIAL SERIES

INDUSTRIAL GRADE WATER SOFTENERS LWT INDUSTRIAL SERIES INDUSTRIAL GRADE WATER SOFTENERS LWT INDUSTRIAL SERIES 1,200,000 TO 3,000,000 GRAINS CAPACITY WATER SOLUTIONS * CUSTOM ENGINEERING * INDUSTRIAL PERFORMANCE (Single, Twin, Triple or Quadruple Demand Systems)

More information

CO2 Incubators The Complete Line

CO2 Incubators The Complete Line CO2 Incubators The Complete Line We culture more than trust. See website for full details. Constant Thinking We are always thinking. Always trying to find new ways to give you top-of-the-line products.

More information

Sioux E-Series. All-Electric Compact Industrial Steam Cleaners & Pressure Washers. Sioux E-Series All-Electric Steam Cleaners and Pressure Washers

Sioux E-Series. All-Electric Compact Industrial Steam Cleaners & Pressure Washers. Sioux E-Series All-Electric Steam Cleaners and Pressure Washers Sioux E-Series All-Electric Steam Cleaners and Pressure Washers Sioux E-Series All-Electric Compact Industrial Steam Cleaners & Pressure Washers Model E3.5HS3000 3 Consider Benefits... these Sioux s E-Series

More information

Electric Submersible Pumps

Electric Submersible Pumps Electric Submersible Pumps Versatile pumps with a wide variety of applications Construction Starts Here www.multiquip.com Electric Submersible Pumps Bolt-on discharge port allows easy replacement Cast

More information

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers.

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers. Issued 2006/08/01 Section 15751 Humidifiers Page 1 of 7 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Submittals..3 Section 01810 Commissioning..4 Section

More information

For demanding applications in life sciences and labs, and as supplier to analysers, autoclaves, glassware washers.

For demanding applications in life sciences and labs, and as supplier to analysers, autoclaves, glassware washers. Omnia pure and ultrapure water systems Convenient. Compact. Adaptable. For demanding applications in life sciences and labs, and as supplier to analysers, autoclaves, glassware washers. H 2 O pure. Pure

More information

Version 7 1/ LXP

Version 7 1/ LXP SECTION 11600 LABORATORY GLASSWARE WASHER Model 1600 LXP PART 1 GENERAL 1.01 SYSTEM DESCRIPTION A. Laboratory Glassware Washer/Dryer 1.02 SUBMITTALS A. Bill of Materials B. Product Literature C. Installation

More information

Semi-Instantaneous Indirect Fired Water Heater

Semi-Instantaneous Indirect Fired Water Heater MODEL BWX Semi-Instantaneous Indirect Fired Water Heater Use Boiler Water Or HTHW To Heat Domestic Water Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone

More information

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS M24E M36E Telephone: (802) 658-6600 Fax: (802)864-0183 www.marketforge.com PN 14-0309 Rev G (11/17) 2017 - Market Forge

More information

Shop Online Eccotemp.com/products. Store Locator Eccotemp.com/locator. Product Support support.eccotemp.com.

Shop Online Eccotemp.com/products. Store Locator Eccotemp.com/locator. Product Support support.eccotemp.com. L5 20 minute automatic safety shutoff timer Battery igniter - no electricity needed Minimum flow rate is approximately 0.4 gallons per minute Up to 18 hours of use on a 20 lb. tank Shower head with On/Off

More information

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the Radiant Warm Wall Compact Incubator Reduced Oxygen Incubator Automatic Water-Jacketed Incubator, stacked For more than 45 years, Lab-Line has been on the cutting edge of incubator development. Not only

More information

CENTRIVAP CENTRIFUGAL CONCENTRATORS & COLD TRAPS

CENTRIVAP CENTRIFUGAL CONCENTRATORS & COLD TRAPS CENTRIVAP CENTRIFUGAL CONCENTRATORS & COLD TRAPS 2 CENTRIVAP CENTRIFUGAL CONCENTRATORS & COLD TRAPS Page An Overview An Overview 2 CentriVap Benchtop Centrifugal Concentrators 4 Features and Benefits

More information

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data W A T L O W The Watlow FIREROD not only set the industry standard for cartridge heaters, it continues making improvements in construction and design. Among those improvements is the metric FIREROD, a variation

More information

GIRTON CABINET WASHER MODEL 794A

GIRTON CABINET WASHER MODEL 794A DESCRIPTION GIRTON CABINET WASHER MODEL 794A The washer shall be a Girton Model 794A Cabinet Type Pressure Washer constructed of type-304 stainless steel, utilizing a reciprocating header spray system.

More information

Silhouette. Feedwater Heater. Boiler Feedwater

Silhouette. Feedwater Heater. Boiler Feedwater Roth Roth Low Low Silhouette Silhouette TRAY DEAERATORS Boiler Boiler Feedwater Feedwater Heater Heater Capacities Capacities to to 50,000 50,000 lb/hr lb/hr Model RDTV-150-5-1-2 vertical tray type deaerator

More information

CentriVap. Centrifugal Vacuum Concentrators and Cold Traps

CentriVap. Centrifugal Vacuum Concentrators and Cold Traps CentriVap Centrifugal Vacuum Concentrators and Cold Traps 2 CENTRIVAP VACUUM CONCENTRATORS & COLD TRAPS Page An Overview 2 CentriVap Benchtop Vacuum Concentrators 4 Refrigerated CentriVap Vacuum Concentrators

More information

Cool IR. Model C104 - Cooling System. Instruction Manual

Cool IR. Model C104 - Cooling System. Instruction Manual Cool IR Model C104 - Cooling System Instruction Manual February 26, 2015 Research, Inc. USA Ph: 952.949-9009 Fax: 952.949-9559 tsdsales@researchinc.com www.researchinc.com Table of Contents List of Figures...

More information

Which RO/DI Water Heater is Right For Your Application? By: Caitlin Carrier

Which RO/DI Water Heater is Right For Your Application? By: Caitlin Carrier Which RO/DI Water Heater is Right For Your Application? By: Caitlin Carrier Introduction: Deionized water, referred to as DI Water, has emerged as an indispensable component in process applications. From

More information

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com Spray Flow II Pressurized and Atmospheric Deaerators.005 cc/liter Atmospheric Deaerator CONSTANT RECYCLING guarantees deaeration of all dissolved oxygen in excess of.005 cc/liter from 0% to 100% of deaerator

More information

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com Spray Flow II.00 cc/liter Atmospheric Deaerator Pressurized and Atmospheric Deaerators CONSTANT RECYCLING guarantees deaeration of all dissolved oxygen in excess of.00 cc/liter from 0% to 100% of deaerator

More information

NuPure LAB. Ultrapure and RO with PE Tank USER MANUAL

NuPure LAB. Ultrapure and RO with PE Tank USER MANUAL NuPure LAB Ultrapure and RO with PE Tank USER MANUAL This Manual Is Applicable to the Following NuPure-Direct Models NW0P01000S NuPure-Direct Water System, Ultrapure 10 NW0P02000S NuPure-Direct Water System,

More information

"QT" Drinking Water Systems With Quick Twist Cartridges & Membranes

QT Drinking Water Systems With Quick Twist Cartridges & Membranes Watts "QT" Drinking Water Systems With Quick Twist Cartridges & s They re so easy to change, anyone can do it! Flow shuts off automatically when cartridges are removed. Features & benefits No trips to

More information

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages Point-of-Use Tankless Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages Features Heavy Duty Construction Reliability Constructed with high grade materials to ensure long operating

More information

Domestic Pump Condensate Transfer Equipment

Domestic Pump Condensate Transfer Equipment Bulletin S-944L Domestic Pump Condensate Transfer Equipment CONDENSATE RETURN UNITS BOILER FEED UNITS LOW NPSH PUMPS VACUUM HEATING UNITS INDUSTRIAL VACUUM UNITS www.domesticpump.com Condensate Return

More information

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with

More information

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents Hoffman Specialty Regulators Main Steam How to Select Steam Model Radiator Convector Unit Thermostatlic Number (Angle Type) (Bottom Inlet) Heater Mains Vent (only) Remarks 1A X Adjustable Orifice 70A X

More information

Description. Applications

Description. Applications CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW

More information

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133. Main Steam How to Select Steam For Steam Vent selection information, please refer to Selection Guidelines on page 133. Model Radiator Convector Unit Thermostatlic Number (Angle Type) (Bottom Inlet) Heater

More information

PART 1 - GENERAL 1.1 WORK INCLUDED

PART 1 - GENERAL 1.1 WORK INCLUDED PART 1 - GENERAL 1.1 WORK INCLUDED A. Nortec ML Series high pressure adiabatic in-space system[s] as indicated on drawing[s] and as indicated on schedule[s]. B. Complete and operable humidification system

More information

QUICK SET-UP GUIDE LX-5085-QS. Xe-2 Xenon Test Chamber

QUICK SET-UP GUIDE LX-5085-QS. Xe-2 Xenon Test Chamber QUICK SET-UP GUIDE LX-5085-QS Xe-2 Xenon Test Chamber Revision Date 07 Apr 2016 Table of Contents Page 1. Purpose...33 2. Unpacking...33 3. Placement...4 4 4. Ventilation...4 4 5. Electrical...5 5 6. Water

More information

HWD-2110 Hot Water Dispenser

HWD-2110 Hot Water Dispenser User s Guide t f Touch Function Selector Technology HWD-2110 Hot Water Dispenser. NOTICE TO INSTALLER: Please leave this book with the machine. Temperature On Demand US design patent applied for. Other

More information

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY PRIME COMMERCIAL CONDENSING GAS WATER HEATER 40-119 GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY WATER HEATERS TM (Optional) TM THE ULTIMATE IN CONDENSING GAS WATER HEATING THE PRIME ADVANTAGE Industry's

More information

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance VMS-3 Part Number: 95-0031 Ultraviolet Systems VMS-3 Installation, Operation & Maintenance The following are the types of flags used in this technical manual. They designate safety related items and important

More information

Hot Water Boilers 810(E), 815(E), 830(E), 850(E) Table of Contents

Hot Water Boilers 810(E), 815(E), 830(E), 850(E) Table of Contents Hot Water Boilers 810(E), 815(E), 830(E), 850(E) Operator Manual Model 810(E) Safety Information...2 Rough-In Drawing...3 General Description...4 Installation...4 Priming...5 Cleaning...5 Table of Contents

More information

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE. Temperature Control Units Water & Oil 0-00 F Portable Chillers 0 - F Central Chillers Packages & Modules 0 - F Pump Tank Stations Chilled or Tower Water 00-0 gallons Cooling Tower Cells 4-40 tons Filters

More information

Hoffman Specialty Pump Products

Hoffman Specialty Pump Products Condensate Units Boiler Feed Units Vacuum Heating Units Hoffman Specialty Pump Products S-0692C INDEX Condensate Return Units Series WC Series WCS Series SCC Boiler Feed Units Stock Watchman Condensate

More information

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles.

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles. 35 Evaporation of waste wash water occurs during normal operation of the pressure, steam or automatic vehicle wash system. It is generally assumed that 10-30% of wash water is lost to evaporation. Accelerated

More information

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase Features Heavy Duty Construction Constructed with high grade materials to ensure long operating life Turn-Key package is simple to specify and operate Factory wired electrical controls provide trouble-free

More information

Owners Manual. Model MINI-CLASSIC CT. Pure Water. Water Distiller

Owners Manual. Model MINI-CLASSIC CT. Pure Water. Water Distiller FOR THE RECORD The model and serial number are found on the back panel. You should record both the model and serial number from the back of the machine for future reference. Model MINI-CLASSIC CT Date

More information

Tel: Fax: Website:

Tel: Fax: Website: Vacuum Dehydration Oil Purification System(Oil Purifier) The water and particles contamination in lubrication, hydraulic and dielectric oils badly affect the oils performance and threaten system reliability.

More information

Owners Manual MINI-CLASSIC II. Pure Water. Water Distiller

Owners Manual MINI-CLASSIC II. Pure Water. Water Distiller FOR THE RECORD The model and serial number are found on the back panel. You should record both the model and serial number from the back of the machine for future reference. Model Date of Purchase Serial

More information

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

PROVIDES TEPID WATER FOR EMERGENCY SHOWER PROVIDES TEPID WATER FOR EMERGENCY SHOWER Model EMV FEATURES Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon alloy tappings cannot rust or corrode High impact composite

More information