1 INDIVIDUAL DRIVE, CHAIN DRIVE AND U- SEAL MECHANISM IN ROLLER HEARTH NORMALISING FURNACE Akash Kumar Mechanical Engineering Dronacharya College of Engg. Gurgaon, Haryana Abstract:- This project deals with the study and review of STUDY THE CHAIN DRIVE, INDIVIDUAL DRIVE MECHANISM ROLLER AND FUNCTION OF U-SEAL IN FURNACE OF PLATE MILL. Normalizing is a process of heating the plates to soaking temperature depending upon the composition of metal, cooling them in air. An industrial furnace in which stacked items are heated in an insulated car that is rolled out of the furnace on rollers or chutes, guided by rails or a grooved way. A crane is used to load and unload items for processing on the car, or roller hearth. Sand or water are used to seal gaps between the roller hearth and the walls in order to decrease the intake of air into the furnace. The heating time of plates in the furnace depends on the thickness of the plate. Equipment to heat metals to the desired temp for Change shape, Change properties. Liquid/gaseous fuel or electricity type of fuel are mostly used. Provision of water U-seal in the gas pipe line of normalizing furnace for gas safety. Keywords: U-seal, roller hearth normalizing furnace INTRODUCTION Roller Hearth Normalising Furnace Roller Hearth Normalising Furnace an industrial furnace in which stacked items are heated in an insulated car that is rolled out of the furnace on rollers or chutes, guided by rails or a grooved way. A crane is used to load and unload items for processing on the car, or roller hearth. Sand or water are used to seal gaps between the roller hearth and the walls in order to decrease the intake of air. Charging of Plates 1. Plates placed on the stacks, are picked up by depiler one by one and placed on the charging side roller table of the furnace. 2. Care should be taken to charge plates of one thickness range at a time, as the speed of the roller hearth is set as per thickness of the group of plates. 3. There should not be any abrupt change in the specific heating time of the specific heating time of the groups, the timing to be reset after the overlapping group of plates are discharged from the furnace. 4. There should not be any abrupt change in the specific heating time of the groups, the timing to be reset after the overlapping group of plates are discharged from the furnaces. 5. For the plates of thickness more than 40 mm oscillation regime of the roller hearth is to be followed. 6. As the roller hearth speed is being controlled speed is being controlled from CP-38, the operator of this pulpit should be informed about the thickness of the plates in advance, so that he can set the speed. 7. When plates are placed on the charging side roller table. A charging report is made in a proforma in four copies. This report includes, normalising serial no, plate no., cast no., grade, sale order no., actual size of the plate and finished plate size. 8. After charging about 10 to 12 plates, the copies will be sent to leveller (CP-40) stamper painter, shear and piler staff. 9. Care should be taken to send these copies before plate reaches there. 10. Prior to charging into the furnace the gap between the manipulator is set manually as per the width of the plates. 11. While charging, plates should be placed on the roller table, straight, centrally and slowly. 12. Bend plates, should not be charged. 13. The person at the depiler has to check the availability of plates on the stacks. If any one of the stack is empty, it is to be filled immediately. IJIRT INTERNATIONAL JOURNAL OF INNOVATIVE RESEARCH IN TECHNOLOGY 46

2 14. While charging the plates, a minimum required gap is to be maintained between two plates. 15. Charging should be stopped immediately if there is any hold up in the equipment after furnace or if there is any equipment after furnace or if there any problem in the furnace. Oscillation is manual mode and bring down the temperature gradually depending on the duration of the delay. 16. Any defect in the depiler equipment should be immediately brought to the notice of shift 17. During charging of plates, control operator should follow and ensure correct movement of plates inside the furnace on the roller hearth. It is prohibited to allow shifting of plates towards the wall. 18. In case of shifting of plates are observed inform shift incharge immediately. HEATING OF PLATES 9. Necessary action must be taken to overcome any fault. Concerned heating staff should make necessary entries in the log dook. DISCHARGING OF PLATES 1. Plate discharging from the furnace is a continuous process. 2. When plate is coming out of furnace the lowering and lifting tracks of plate convey or should be in lower positions. 3. Once plate reaches the roller table before plate conveyor, it should be immediately transferred to conveyor bed to make the tracks ready to receive the successive plates. 4. While conveying plates on the conveyor, a minimum required gap is to be maintained between two plates. 5. Any defect in the equipment should be brought to the notice of shift 6. Any hold ups in the equipment after the furnace, the in the equipment after the furnace, the CP- 38 operator should be informed immediately. LEVELLING OF PLATES FIG: PLATES INSIDE THE FURNACE 1. The furnace is operated as per technological instructions (refer heating instructions). 2. Depending on the grades of steel proper temperature has to be maintained in the furnace. 3. The fuel used should be burnt completely within the furnace. Burning of fuel in the flue duct is strictly prohibited. 4. Furnace pressure should kept positive at the level of hearth (roller) for this it is necessary to keep a pressure of + 5 mm WC. 5. The temperature of the flue gases just before the dampers should be properly controlled. The temperature of the flue gases should not exceed 700 C. 6. Air/fuel ratio should be correctly monitored so that fuel gets completely burnt within the furnace. Soot formation is prohibited. 7. Formation of scale during heating should be kept to minimum. 8. Any fault in the instruments should be immediately brought to the notice of shift 1. Levelling is done for plates of thickness from 5mm to mm only. 2. Plate or thickness more than 20mm are let through the leveller by increasing the gap between the leveller rollers. 3. Before feeding the plates into the leveller, plates are to be centered with the help of manipulators. 4. Required gap is to be maintained between rollers as per the thickness of the plate. 5. Thickness change for the plates should be strictly observed, so that gap can be set properly. 6. Leveller cooling system should be checked now and then, physically from the site, as there is no annunciation system for cooling water failure. IJIRT INTERNATIONAL JOURNAL OF INNOVATIVE RESEARCH IN TECHNOLOGY 47

3 7. Any defect in the leveller or manipulator should be brought to the notice of shift 8. Any hold up in the equipment should be informed immediately to CP Back up rolls must rotate along with the work rolls during idle running. If they fail to rotate they are adjusted with the help of proper packing. 10. Scale is cleaned periodically from work rolls and back up rolls by compressed air. 11. Dial reading should correspond to the actual gap. 12. There should not be overlapping of plates during levelling. 13. Plates in skew condition should not be levelled. 14. No foreign material should be present on the plate during levelling. 15. The levelling machine should be stopped immediately if jamming of metal occurs between work rolls, it is prohibited to operate the screw down mechanism or reverse the levelling direction in such a case. 16. Jamming of metal is a serious breakdown which damages the mechanism and all precautions should be taken to avoid it. Chain drive Mechanism In Chain drive mechanism each roller is drived by the chain with the help of motor and reducer. Chain drive is a way transmitting mechanical power from one place to another. The power is conveyed by a roller chain, known as the drive chain or transmission chain, passing over a sprocket gear, with the teeth of the gear meshing with the holes in the links of the chain. The gear is turned, and this pulls the chain putting mechanical force into the system. The invention provides a chain transmission mechanism for a Roller-Hearth furnace, which comprises a transmission chain wheel, a tension pulley and chains which consist of a plurality of pitch chains, wherein the chains are arranged on the transmission chain wheel and the tension pulley. The outside of each chain is provided with planer mound layer in section. The planer mould mound layers are fixed with the furnace wall through a height adjusting mechanism. The chains are driven by the transmission chain wheel to move. Chain drive Mechanism advantage 1. Through one chain the complete line shaft revolve due to this it provides or rotates all the roller of the furnace. 2. By using chain drive mechanism in furnace-1 we get high velocity ratio. 3. The power consumption in chain drive is low as compared to individual drive mechanism. Chain drive mechanism disadvantage 1. The initial set up cost of chain drive mechanism is high. 2. The chances of breakage of chain drive is rarely happens. 3. This mechanism uses lubrication for smooth drive of shaft but in individual drive mechanism lubrication is not required. 4. Small sprocket is used in upper portion of the chain drive so to maintain proper tension in the chain. 5. Sometimes due to heavy load the line shaft chain got break down due to that the power will not be transferred to the roller. 6. After prolonged usage of chain it gets loose to maintain tension the chain either we have to remove some teeth of chain of make the chain tight. 7. The chain linked to the reducer 800 sometimes got break down due to load tolerance. 8. If the chain got breaks down in middle of the process the roller in the roll table also got damaged the rollers either may bend from the neck or some crack will appear on its neck or at its barrel. 9. The time consumption in joining the chain to one breaks or damaged frequently due to this process is not used more. Individual drive mechanism In individual drive mechanism each roller in the furnace is drive by an individual motor. Speed of the each roller is controlled by the help reducer coupled with the motor. Since each roller in the furnace is controlled by the separate motor, there is less chance of breakdown. Advantage of individual drive mechanism 1. The initial set up cost of individual drive system is low as compared to chain drive system. IJIRT INTERNATIONAL JOURNAL OF INNOVATIVE RESEARCH IN TECHNOLOGY 48

4 2. The breakage of disc in individual drive system is not frequently or year can say it occurs sometimes. 3. If one disc got damaged the entire process does not get affected because other discs will revolve & roll table continue to move. 4. The time taken by the disc to get correct is about 2 to 3 hours. 5. If 2 or 3 discs got damaged in the shaft then also the roller will continue to move as plates will pass upon it without any cracks. 6. The speed of the roller can be increased or decreased as per the need in individual drive mechanism. 7. In this to each roller individual motor is installed so if one roller got affected other may continue to work. 8. Maintenance cost in changing the discs of the shaft is also low. 9. Due to individual drive mechanism the chances of bending of roller containing disc in very less. Disadvantages of individual drive mechanism 1. More power consumption occur in individual drive mechanism. 2. Since each roller have individual motor so the cost of the motor & its instalment is also high. 3. If more than 2 or 3 discs of the shaft got damaged the new shaft must be installed to avoid any cracks or bars in the hot plate. U-SEAL U-SEAL before U-seal is a process used to avoid leakage of gases (Mixed gas) from the pipeline and to prevent the hazard caused by leakage of gases by filling the U-shaped gas pipe with clean water at a certain level. The water comes from the water pipeline and deliver it to the inlet of the U-SEAL and filling it upto given level and through outlet valve of U-SEAL excess water gets discharged. This discharging of water gives 100% satisfaction that leakage of gas will not occur during the maintaince of furnace and whole system. In U-SEAL drain valve is also located at the bottom of it which is used to empty the U-SEAL when we need to start the system or say process to work. Through drain valve the water gets discharged and inlet valve is closed so that no supply of water takes place. After that mixed gas is supplied in the gas pipeline. When gases comes out of burner in the furnace, burner is switched on to fire the flame by bringing the flame near the burner of furnace and hence the overall process work. Advantage of using U-SEAL 1. The U-shaped pipeline prevents leakage of gas through the gas pipeline due to its U-shaped design and filling of water in the u-seal. 2. U-seal gives 100% surety. 3. The overall design of the U-SEAL is so appropriate & creative that it gives proper satisfaction against of gas. CONCLUSION Roller Hearth Continuous Normalising Furnace is a heat treatment method, to enhance the mechanical properties of the plate. In roller hearth continuous normalising furnace plate inside the furnace is move from input to output door of the furnace with the help of roller which is drive either by the chain drive mechanism or by the individual drive mechanism. Chain drive mechanism and individual drive mechanism is operated with the help of motor coupled with the reducer. Individual drive mechanism required less maintaince than the chain drive mechanism and also consume less power as compared to chain drive mechanism. The overall shutdown of furnace due to breakage of chain in chain drive mechanism is overcome by the new design i.e. individual drive mechanism. It also saves the maintaince cost of drive mechanism due to less breakdown of drive mechanism. U-seal is a process used to avoid leakage of gases (Mixed gas) from the gas pipeline and to prevent the hazard caused by leakage of gases by filling the U- shaped gas pipe with clean water at a certain level. IJIRT INTERNATIONAL JOURNAL OF INNOVATIVE RESEARCH IN TECHNOLOGY 49

5 This gives the 100% surety that there is no chance of leakage of gases through the gas pipeline. REFERENCES [1] Bhilai Steel Plant Intranet. [2] Gateway-An Introductory Guide to Bhilai Steel Plant, Edition 2009, Editor - Manas Shukla, DGM (HRD), Bhilai steel Plant. [3] (Retrieved on 1/7/2012) [4] Daniel Automation Specification Sheet for roughing and finishing stand. [5] Enterprise Resource Planning Software, Plant Maintenance Module. [6] Davies, Clive (1970). Calculations in furnace technology (1st ed.). Pergamon Press. ISBN [7] Goldstick, R. and Thumann, A (1986). Principles of waste heat recovery. Fairmont Press. ISBN [8] ASHRAE (1992). ASHRAE Handbook. Heating, ventilating and air-conditioning systems and equipment. ASHRAE. ISBN ISSN [9] Perry, R.H. and Green, D.W. (Editors) (1997). Perry's Chemical Engineers' Handbook (7th ed.). McGraw-Hill. ISBN [10] Lieberman, P. and Lieberman, Elizabeth T (2003). Working Guide to Process Equipment (2nd ed.). McGraw-Hill. ISBN [11] Furnaces, Incinerators, Kilns at DMOZ IJIRT INTERNATIONAL JOURNAL OF INNOVATIVE RESEARCH IN TECHNOLOGY 50

Design, Manufacturing and Analysis of Transmission Device Cutting Tools for Automobiles.

Design, Manufacturing and Analysis of Transmission Device Cutting Tools for Automobiles. Design, Manufacturing and Analysis of Transmission Device Cutting Tools for Automobiles. Divya T M.Tech (CAD/CAM), Department Of Mechanical Engineering, Malla Reddy College Of Engineering. ABSTRACT Transmission

More information

TLA-1245 EFFICIENT HEAT CYCLE SHRINK TUNNEL OPERATION MANUAL

TLA-1245 EFFICIENT HEAT CYCLE SHRINK TUNNEL OPERATION MANUAL TLA-1245 EFFICIENT HEAT CYCLE SHRINK TUNNEL OPERATION MANUAL Contents 1. Introduction... 3 1.1 Features... 3 1.2 Specifications... 3 2. Installation... 3 3. Machine explosion drawing... 4 4. Equipment

More information

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL Heating, Air Conditioning, Ventilation Отопление-Кондиционеры-Вентиляция MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL 1. Usage MTM 8-30 universal oil heater is designed for heating commercial rooms

More information

S. H. Gawande, L. G. Navale, A. A. Keste (Department of Mechanical Engineering, M. E.S. Collegeof Engineering, Pune, India)

S. H. Gawande, L. G. Navale, A. A. Keste (Department of Mechanical Engineering, M. E.S. Collegeof Engineering, Pune, India) IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) ISSN(e) : 2278-1684, ISSN(p) : 2320 334X, PP : 15-21 www.iosrjournals.org Design, Development & Validation of Sand Washing Machine S. H. Gawande,

More information

FAN PERFORMANCE AND UTILIZATION OF COMPRESSED AIR IN THERMALPOWERPLANT

FAN PERFORMANCE AND UTILIZATION OF COMPRESSED AIR IN THERMALPOWERPLANT FAN PERFORMANCE AND UTILIZATION OF COMPRESSED AIR IN THERMALPOWERPLANT V Hari Kiran 1, K Uday Kiran Kumar 2, M M Praveen Kumar 3 1 Asst.Proffessor, Avanthi Institute Of Engineering And Technology, Makavaripalem,

More information

FD Heavy Duty Feeder for FD 280 Tabbing System

FD Heavy Duty Feeder for FD 280 Tabbing System FD 280-10 Heavy Duty Feeder for FD 280 Tabbing System Operator Manual 8/2011 First Edition TABLE OF CONTENTS 1. INTRODUCTION... 1 1.1 Feeder Description... 1 1.2 Items Included... 1 1.3 Operating Manual

More information

Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments

Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments 1 P age Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments 2 P age Keywords: Pipe still heater, heat exchangers, distillation tower, pumps Refinery equipments Introduction In refinery,

More information

Boiler Draft Equipment

Boiler Draft Equipment Boiler Draft Equipment Learning Outcome When you complete this module you will be able to: Discuss, sketch and describe the basic equipment used to supply combustion air to a boiler furnace. Learning Objectives

More information

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas Journal of Contemporary Issues in Business Research ISSN 2305-8277 (Online), 2013, Vol. 2, No. 4, 109-123. Copyright of the Academic Journals JCIBR All rights reserved. NFPA 85 COMPLIANCES OF BMS: A CASE

More information

OCEANO BOTTLE WASHER

OCEANO BOTTLE WASHER OCEANO BOTTLE WASHER OCEANO In the effort to reduce the environmental impact of waste from industrial production, there is an increasingly deeplyfelt need to recover empty containers, such as glass or

More information

WHEN TROUBLESHOOTING, PERFORM THE STEPS IN ORDER.

WHEN TROUBLESHOOTING, PERFORM THE STEPS IN ORDER. WHEN, PERFORM THE STEPS IN ORDER. BURNER WON T LIGHT Control System 1. Is the main interlock in auto? The burner will not light if the dryer is in manual mode b. No: Switch the main interlock to auto 2.

More information

WASHING CYCLE. In the most sophisticated machine Version (DH 3), all the following steps are included.

WASHING CYCLE. In the most sophisticated machine Version (DH 3), all the following steps are included. HYDRA BOTTLE WASHER HYDRA The Hydra bottle washer has been designed for mediumhigh speed production (from 30,000 bph up to 120,000 bph 500 ml bottles) and particularly for those clients who are better

More information

AQUA LOW-MEDIUM SPEED BOTTLE WASHER

AQUA LOW-MEDIUM SPEED BOTTLE WASHER AQUA LOW-MEDIUM SPEED BOTTLE WASHER BOTTLEWASHER AQUA WASHING CYCLE THE WASHING CYCLE CONSISTS OF FOUR DISTINCT PHASES. Pre-wash The pre-soaking stage takes place in one or two stages; after leaving the

More information

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT

More information

Boiler Technical Specifications (2013)

Boiler Technical Specifications (2013) ACT Bioenergy Boiler Dimensions 0.5-0.85 Million Btu/h (150-250kW) Model CP500 CP600 CP750 CP850 Heat Output in MBtu/h (kw) 510 (150) 610 (180) 750 (220) 850 (250) Height ft (mm) 6 1 (1855) 6 1 (1855)

More information

USER'S MANUAL PGE Single Package Rooftop

USER'S MANUAL PGE Single Package Rooftop USER'S MANUAL PGE Single Package Rooftop Gas Heating/Electric Cooling Units Sizes 036-150 3 to 12-1/2 Tons NOTE TO INSTALLER: This manual should be left with the equipment owner. WARNING: If the information

More information

MULTIPLEX SELF RECUPERATIVE gas burner

MULTIPLEX SELF RECUPERATIVE gas burner Installation - Maintenance MULTIPLEX SELF RECUPERATIVE gas burner SERIES MPSR The Nu-way Multiplex Recuperative System offers the alternative of a self-recuperative burner or a separate recuperator and

More information

Laminator ZJY Series User Manual

Laminator ZJY Series User Manual Laminator ZJY Series User Manual Eastsign International Limited Room 1818, 18/F., Shatin Galleria, 18-24 Shan Mei Street, Fotan, Shatin, N.T., Hong Kong TEL: + 852-2117 0098 FAX: + 852-2117 0099 Website:

More information

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified Thank you for purchasing our fully-automatic gas-fired tankless water heater. Please completely read this Manual

More information

Performance Evaluation of Vegetable Washer for Carrot Crop

Performance Evaluation of Vegetable Washer for Carrot Crop International Journal of Current Microbiology and Applied Sciences ISSN: 2319-7706 Volume 7 Number 01 (2018) Journal homepage: http://www.ijcmas.com Original Research Article https://doi.org/10.20546/ijcmas.2018.701.053

More information

ASTRO ENVELOPE FEEDER AMC FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS

ASTRO ENVELOPE FEEDER AMC FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS ASTRO ENVELOPE FEEDER AMC-2000-17 FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION Thank you for purchasing the Astro Envelope Feeder. It is fast, efficient, reliable, and

More information

Mobile dual-shaft shredder CRAMBO

Mobile dual-shaft shredder CRAMBO Mobile dual-shaft shredder CRAMBO Model: Type: CRAMBO 3400D / 5000D / 6000D Series number: 169 078 Year of construction: 2011 Copyright 2011 KOMPTECH Umwelttechnik GmbH. All rights reserved. Print: 03/2011

More information

Installation & Maintenance Manual

Installation & Maintenance Manual Installation & Maintenance Manual MOL 200 S1L (B30A) Oil Burner 11/12 Tel: +44 (0) 1905 794331 Fax: +44 (0) 1905 794017 Email: info@nu-way.co.uk Web: www.nu-way.co.uk DESCRIPTION COMPONENTS 1. Shrouded

More information

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. www.windsterhood.com User s Manual UNDER CABINET SERIES WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed

More information

Efficiency and Design Improvements in Multiple Hearth & Fluid Bed Incinerators

Efficiency and Design Improvements in Multiple Hearth & Fluid Bed Incinerators Efficiency and Design Improvements in Multiple Hearth & Fluid Bed Incinerators CBE Chavond-Barry Engineering 400 Rt. 518, Blawenburg, NJ 08504 Outline Fluid Bed Incinerators (FBI s) - Reversible Bed Resizing

More information

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

POWER VENTER SYSTEM. Model: PVO-300, PVO-600 POWER VENTER SYSTEM Model: PVO-300, PVO-600 Included is one ETL and cetl listed Power Venter to be used primarily with a single 120VAC controlled oil fired furnace, boiler, or water heater. The PVO may

More information

User s Information Manual

User s Information Manual 62DA,DB,DC,DD07-38 Vertical or Horizontal Dedicated 100% Outdoor Air Unit with Optional Gas Heat User s Information Manual NOTE TO INSTALLER This manual should be left with the equipment owner. : If the

More information

Paver Operation 101 Paving for Uniform Texture and Smoothness

Paver Operation 101 Paving for Uniform Texture and Smoothness Paver Operation 101 Paving for Uniform Texture and Smoothness RMACES February 2016 Paver Operation 101 Paving By The Numbers Paving for Uniform Texture Paving for Ride Paving by the Numbers Step 1 Heat

More information

SOP: LFA SOP For Automatic Capsule Filling Machine

SOP: LFA SOP For Automatic Capsule Filling Machine SOP For Automatic Capsule Filling Machine Alastair Sanderson 31/08/16 1 Objective To provide the operating procedure for Automatic Capsule Filling Machine. 2 Scope Includes the operating procedure for

More information

Android Controlled Fire Fighting Robot

Android Controlled Fire Fighting Robot IJSTE - International Journal of Science Technology & Engineering Volume 3 Issue 09 March 2017 ISSN (online): 2349-784X Android Controlled Fire Fighting Robot S. Sakthi Priyanka R. Sangeetha Department

More information

AUTOMATION OF BOILERS USING LABVIEW

AUTOMATION OF BOILERS USING LABVIEW I J L S C M 4(1), 2012, pp. 49-53 AUTOMATION OF BOILERS USING LABVIEW A. MICHAEL SIDDHARTHA AND S. NAVEEN KUMAR Under Graduate Student, Department of Electronics and Communication Engineering Thiagarajar

More information

Bringing a Steam Boiler On-Line from Cold.

Bringing a Steam Boiler On-Line from Cold. Bringing a Steam Boiler On-Line from Cold. To help understand what needs to be done and why things need to be done in a certain way, the following procedure presumes that the boiler is completely cold

More information

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing Important: To protect the unit and avoid damage to the heat exchanger, the blower speed

More information

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only. www.windsterhood.com User s Manual UNDER CABINET SERIES RA-3030SS RA-3036SS NOTE: This unit was designed for indoor residential use and DUCTED operation only. DO NOT USE OVER A WOOD GRILL OR MOUNT OUTDOOR

More information

Machine Guarding BLR B L B R usi ne B s u s si & n e L s e s g a & l L R e e g s a o l u r R c e e s s o(u 1rc 7 e 1 s 0) 1

Machine Guarding BLR B L B R usi ne B s u s si & n e L s e s g a & l L R e e g s a o l u r R c e e s s o(u 1rc 7 e 1 s 0) 1 Machine Guarding BLR Business BLR Business & Legal & Resources Legal Resources (1710) 1 Session Objectives Recognize machine hazards Identify hazardous machine parts Identify and use machine guards Follow

More information

ANNEXURE-A SPECIFICATIONS FOR HOT MIX PLANT

ANNEXURE-A SPECIFICATIONS FOR HOT MIX PLANT ANNEXURE-A SPECIFICATIONS FOR HOT MIX PLANT COLD AGGREGATE BIN FEEDER FEEDING HOPPERS Four Nos. Cold aggregates hopper with a heaped capacity of approx. 52 T. Wide opening bin width to accommodate different

More information

User s Manual WS-68N30SS WS-68N36SS WS-68N42SS

User s Manual WS-68N30SS WS-68N36SS WS-68N42SS ISLAND SERIES www.windsterhood.com User s Manual WS-68N30SS WS-68N36SS WS-68N42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section

More information

OPTIMISATION OF SOOT BLOWER OPERATION IN BOILER TO IMPROVE EFFICIENCNY

OPTIMISATION OF SOOT BLOWER OPERATION IN BOILER TO IMPROVE EFFICIENCNY OPTIMISATION OF SOOT BLOWER OPERATION IN BOILER TO IMPROVE EFFICIENCNY K.Vijay 1, Dr. B. Karthikeyan 2 1PG Student, Department of Mechanical Engineering, Annamalai University, chidambaram. 2Associate professor,

More information

Automatic Temperature Control (ATC) is a system that operates the broiler at two different energy rates. 1. High energy input - for initial warm-up and periods of high volume. 2. Low energy input - for

More information

THE DESIGN & BUILT OF CRUSHER MACHINE PLASTIC BOTTLES

THE DESIGN & BUILT OF CRUSHER MACHINE PLASTIC BOTTLES THE DESIGN & BUILT OF CRUSHER MACHINE PLASTIC BOTTLES Akmal Bin Uzir* Tel :+6014-8025788 Email: akmal@psp.edu.my Khairuddin Bin Ishak* Tel :+6019-4746245 Email: khairudin@psp.edu.my Norhafizah Akmal Binti

More information

Instructions for using the PerkinElmer DSC-8500

Instructions for using the PerkinElmer DSC-8500 Instructions for using the PerkinElmer DSC-8500 Safety and Precautions: Check the temperature of the sample holder before removing items from the instrument. Check the melting point of the sample pan,

More information

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings POWDER GUIDE From ASIAN PAINTS (I) LTD Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings Section A : Powder Application Problems Trouble Possible Causes Solutions 1. Poor charging

More information

Draft and Venting. Chapter 6

Draft and Venting. Chapter 6 Chapter 6 Introduction Air is needed to burn oil cleanly and efficiently. We must understand how to supply air to the burner and how to ensure that all of the gases created in burning the fuel are vented

More information

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS SECTION 237339 - DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

V-VTP Maintenance Manual

V-VTP Maintenance Manual V-VTP Maintenance Manual PO Box 501 Denver, NC 28037 ph: 704-483-9316 / fx: 704-483-4538 sales@leonardautomatics.com - http://leonardautomatics.com Maintenance Guide Proper maintenance of the tunnel finisher

More information

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual. 1 MHG Heating Ltd ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual. Unit 4 Epsom Downs Metro Centre, Waterfield, Tadworth, Surrey, KT20 5LR Telephone 08456 448802 Fax 08456 448803

More information

THERMAX Efficiency Monitor

THERMAX Efficiency Monitor INSTALLATION & OPERATION INSTRUCTIONS THERMAX Efficiency Monitor Oil & Gas Fired Heating Equipment Efficiency Monitoring Instrument Important Safety Instructions Read and safe these instructions before

More information

USE OF HOEKEN S AND PANTOGRAPH MECHANISMS FOR CARPET SCRAPPING OPERATIONS. IIT Delhi, Hauz Khas, New Delhi

USE OF HOEKEN S AND PANTOGRAPH MECHANISMS FOR CARPET SCRAPPING OPERATIONS. IIT Delhi, Hauz Khas, New Delhi USE OF HOEKEN S AND PANTOGRAPH MECHANISMS FOR CARPET SCRAPPING OPERATIONS S.K. Saha 1, Rajendra Prasad 2 and Ananta K. Mandal 2 1 Department of Mechanical Engineering, 2 Center for Rural Development and

More information

Diocese of Cleveland Facilities Services Corporation

Diocese of Cleveland Facilities Services Corporation Diocese of Cleveland Facilities Services Corporation BOILER MAINTENANCE and SERVICING SEASONAL MAINTENANCE - to be performed by trained boiler technician or boiler contractor only: 1. Disassemble the low

More information

Design, Manufacturing of Chilled Water System for Process Cooling Application

Design, Manufacturing of Chilled Water System for Process Cooling Application IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 11 May 2016 ISSN (online): 2349-784X Design, Manufacturing of Chilled Water System for Process Cooling Application Prof.

More information

Top Notch Geared Motors for Energy Efficient Heating Systems Drives for Biomass Heating Systems

Top Notch Geared Motors for Energy Efficient Heating Systems Drives for Biomass Heating Systems Top Notch Geared Motors for Energy Efficient Heating Systems Drives for Biomass Heating Systems Not only higher energy cost but also lower CO 2 emissions make wood chips or pellets biomass boiler heating

More information

PERFORMANCE EVALUATION AND RECURRING JAMMING PROBLEM ANALYSIS OF AIR PREHEATER IN COAL-FIRED POWER PLANTS

PERFORMANCE EVALUATION AND RECURRING JAMMING PROBLEM ANALYSIS OF AIR PREHEATER IN COAL-FIRED POWER PLANTS PERFORMANCE EVALUATION AND RECURRING JAMMING PROBLEM ANALYSIS OF AIR PREHEATER IN COAL-FIRED POWER PLANTS M.Srinivasa Rao M.Tech Student, Department of Mechanical Engineering, GMRIT, Srikakulam, AP, India.

More information

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY Bousquet Technologies Inc. 2121, Nobel, Ste Julie, Quebec, Canada, J3E1Z9 SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL Oil-Fired air heater for industrial and commercial use. FOR YOUR SAFETY Do not

More information

Laboratory Twin-Screw Kneader Modular design easy to use versatile in application

Laboratory Twin-Screw Kneader Modular design easy to use versatile in application Laboratory machines for the processing of polymers Laboratory Twin-Screw Kneader Modular design easy to use versatile in application ZK 25 ZK 35 ZK-D The flexible laboratory machine for co-rotation and

More information

The Application of Double-deck Inorganic Composite Fire Resisting Shutters in Constructional Engineering Bai-Xia ZHOU*

The Application of Double-deck Inorganic Composite Fire Resisting Shutters in Constructional Engineering Bai-Xia ZHOU* 2nd Annual International Conference on Advanced Material Engineering (AME 2016) The Application of Double-deck Inorganic Composite Fire Resisting Shutters in Constructional Engineering Bai-Xia ZHOU* Public

More information

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods

More information

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel.

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel. MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) Q 1. a) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel. 2) steam turbine- It is a device that extract

More information

FD 430 Envelope Sealer

FD 430 Envelope Sealer FD 430 Envelope Sealer 1/2018 OPERATOR, MAINTENANCE, & PARTS MANUAL REV. 1 2 CONTENTS 1 SAFETY INSTRUCTIONS... 5 1.1 Symbols and reference key... 5 1.2 Basic safety precautions... 6 1.3 Safety advice...

More information

PUGMILL/MIXER. Instruction Manual NVS-07

PUGMILL/MIXER. Instruction Manual NVS-07 92895B PUGMILL/MIXER Instruction Manual NVS-07 Attention After carefully reading this manual, be sure to store it in a safe and convenient place for easy reference. Before using this unit, please read

More information

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY.

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY. KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters Table of Contents FOR YOUR SAFETY Page # Topic If you smell gas: 1 Description of Operation 1 Receiving the

More information

ST 40 Oil Burner. Installation & Maintenance Manual

ST 40 Oil Burner. Installation & Maintenance Manual ST 40 Oil Burner Installation & Maintenance Manual 178 093 13 Thank you for choosing a Nu-way burner. As you would expect from a Company who has a pedigree of more than 75 years in the heating industry,

More information

CONDITIONS OF SALE AND WARRANTY

CONDITIONS OF SALE AND WARRANTY M.E.P. Mbl 100 Monoblock - Operator s handbook CONDITIONS OF SALE AND WARRANTY 1. Read carefully this operator's handbook before operating our Mbl 100 Monoblock. 2. M.E.P. guarantees his Mbl 100 Monoblock

More information

EAGLE 2000B EAGLE 2000BE EAGLE 2000EBT MUST READ MANUAL PRIOR TO INSTALLING MACHINE

EAGLE 2000B EAGLE 2000BE EAGLE 2000EBT MUST READ MANUAL PRIOR TO INSTALLING MACHINE EAGLE 2000B EAGLE 2000BE EAGLE 2000EBT MUST READ MANUAL PRIOR TO INSTALLING MACHINE Contents 1 Machine Safety Information 3 1.5 Safety Precautions Prior to Operating Machine 6 2 Machine Installation 7

More information

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information... - TABLE OF CONTENTS Table of Contents 1 www.windsterhood.com Safety Information... 2 3 ISLAND SERIES User s Manual RA-7630SS RA-7636SS RA-7642SS RA-7648SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING.

More information

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are: Heating of Crude Oil 1.Introduction: There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are: Heat Exchangers. Tube Still Heaters (Furnaces).

More information

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. WALL MOUNT SERIES www.windsterhood.com User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed

More information

Vibration Of Cooling Tower Fans. Barry T. Cease Cease Industrial Consulting Vibration Institute 2015

Vibration Of Cooling Tower Fans. Barry T. Cease Cease Industrial Consulting Vibration Institute 2015 Vibration Of Cooling Tower Fans Barry T. Cease Cease Industrial Consulting Vibration Institute 2015 ceasevibration@icloud.com (843) 200-9705 1 WHAT IS A COOLING TOWER AND WHAT DOES IT DO? All cooling towers

More information

Rich Knoelke. Questions or Comments: Mulcahy Shaw Water.

Rich Knoelke. Questions or Comments: Mulcahy Shaw Water. Rich Knoelke Mulcahy Shaw Water Questions or Comments: rknoelke@mulcahyshaw.com CASE STUDY LaCrosse WI WWTP Four New Turbo Blowers New Diffusers with Tapered Layout DO Control System Automated Air Valves

More information

Bliss Box Former Troubleshooting. 6.1 Troubleshooting Chart. Troubleshooting INTRODUCTION SAFETY PROCEDURES

Bliss Box Former Troubleshooting. 6.1 Troubleshooting Chart. Troubleshooting INTRODUCTION SAFETY PROCEDURES 6.0 Bliss Box Former 1.0 INTRODUCTION Table 6-1 provides a logical sequence of tests that are designed to isolate problems with the Bliss Box Former machines. This table includes a list of probable causes

More information

PLYWOOD INDUSTRY JOB EVALUATION PROGRAM JOB DESCRIPTION. Points: 242 Grade: 18

PLYWOOD INDUSTRY JOB EVALUATION PROGRAM JOB DESCRIPTION. Points: 242 Grade: 18 PLYWOOD INDUSTRY JOB EVALUATION PROGRAM JOB DESCRIPTION Date Revised: 16-Feb-12 Points: 237 Grade: 17 Date Prepared: 30-Apr-14 Points: 242 Grade: 18 Person Interviewed or Comment: No. of Incumbents: 1.

More information

Fig. 1. Bottle Height---Top of bottle MUST be at this height or slightly higher.

Fig. 1. Bottle Height---Top of bottle MUST be at this height or slightly higher. P12 Corker Addendum: Setup and Maintenance Read this addendum and the MEP manual carefully before operating the corker. One person should be assigned to maintain the corker. Only this primary operator

More information

Bottle Height Adjustment Bottle Diameter Adjustment Cork Length Adjustment Cork Depth Adjustment

Bottle Height Adjustment Bottle Diameter Adjustment Cork Length Adjustment Cork Depth Adjustment P55 Champagne Corker Setup and Maintenance Read this carefully before operating the corker. One person should be assigned to maintain the corker. Only this primary operator should make adjustments to the

More information

KF-250 Knife Folding Machine

KF-250 Knife Folding Machine KF-250 Knife Folding Machine Serial Number Date Page left blank intentionally 2 Table of Contents INTRODUCTION... 5 PREFACE... 5 SPECIFICATIONS... 5 ELECTRICAL SPECIFICATIONS... 6 SAFETY PROCEDURES...

More information

Shredder FD 8906CC Cross-Cut

Shredder FD 8906CC Cross-Cut Shredder FD 8906CC Cross-Cut 1/2017 OPERATOR MANUAL Machine Specs Model: FD 8906CC Motor Power Sheet Capacity Serial #: 7.5KW (10HP) Three-phase, 220V, 50/60 Hz, 50 Amp dedicated line required, CS8365

More information

SULPHUR RECOVERY UNIT

SULPHUR RECOVERY UNIT 19 October 2015 SULPHUR RECOVERY UNIT START-UP CONSIDERATIONS SHRIKANT KOLI BLACK & VEATCH, MUMBAI Agenda - Burner Management System - Control Loops - Refractory Dry-Out - Start-up Experiences 2 Burner

More information

E Labelers Wraparound Labeling for Cylindrical Containers

E Labelers Wraparound Labeling for Cylindrical Containers NI I EW WAY BULLETIN El E Labelers Wraparound Labeling for Cylindrical Containers Model E5 Labeler shown with STD casters, deep label bed and guard package. Fig. 1622. "A step ahead in packaging" Featurr

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

Mobile single-shaft shredder TERMINATOR

Mobile single-shaft shredder TERMINATOR Mobile single-shaft shredder TERMINATOR Model : Type : TERMINATOR 3400D / 3400SD / 5000D/ 5000SD / 6000D Serial number : 183 042 Year of construction : 2014 Copyright 2011 KOMPTECH Umwelttechnik GmbH.

More information

Importance of a Draught Regulator

Importance of a Draught Regulator Importance of a Draught Regulator The purpose of a chimney (stack) is to generate a draught (draft) that will transport smoke and fumes away from the point of combustion. The chimney design and arrangement

More information

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit Packaged Gas/Electric Units Owner s Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK HAZARD. FIRE OR EXPLOSION HAZARD Disconnect power at fuse box or service panel before performing

More information

RTP9 ROTARY TABLET PRESS USER MANUAL

RTP9 ROTARY TABLET PRESS USER MANUAL RTP9 ROTARY TABLET PRESS USER MANUAL LFA Tablet Presses is a trading name of LFA Machines Oxford LTD All of the content in this document is covered by copyright CONTENTS Page 1. Introduction Page 1. Technical

More information

Technical Data. Name: ERIKA Automat fully automatic machine to divide and to round dough pieces of the same size

Technical Data. Name: ERIKA Automat fully automatic machine to divide and to round dough pieces of the same size AUTOMAT MANUAL 1 Technical Data Name: ERIKA Automat fully automatic machine to divide and to round dough pieces of the same size Type Divisions Dough Portions (in ounces) Plate Nos. 3 30 1.0 3.5 #35 4/40A

More information

NISH Report: Team Catalyst Paper Folding Machine

NISH Report: Team Catalyst Paper Folding Machine 1 : Team Catalyst Paper Folding Machine ABSTRACT Ohio University s Team Catalyst was given a task to find a customer who was physically or mentally handicapped and required further assistance in order

More information

ADVANCED Series 15P1 17P2 19P2

ADVANCED Series 15P1 17P2 19P2 A WIRTGEN GROUP COMPANY Continuous Mobile Asphalt Plants ADVANCED Series 15P1 17P2 19P2 02 03 The Advanced plants line combines the maximum portability of a continuous production plant with the quality

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

English CNA-CNB. Centrifugal fans Installation and maintenance

English CNA-CNB. Centrifugal fans Installation and maintenance 916505-0 English CNA-CNB Centrifugal fans Installation and maintenance 916505-0 GB Centrifugal fans types CNA, CNB, CNA-M and CNB-M installation and maintenance 1. Application 2. Handling 2.1 Marking 2.2

More information

Product range storage technology

Product range storage technology POTATO TECHNOLOGY BEET TECHNOLOGY VEGETABLE TECHNOLOGY Product range storage technology Gentle storing harvesting success! Only crop that is stored in a healthy condition will also be in a healthy state

More information

AMC400A Chocolate Enrober Instruction manual

AMC400A Chocolate Enrober Instruction manual AMC400A Chocolate Enrober Instruction manual Content Preface Chapter One Safety Instructions Chapter Two Specification and Installation Chapter Three Operation and Usage Chapter Four Repair and Maintenance

More information

BWS-60 Wire Stripping machine. Operation Manual

BWS-60 Wire Stripping machine.  Operation Manual BWS-60 Wire Stripping machine www.copper-wire-stripper.com Operation Manual Table of Contents 1. Security declaration 1 2. Specification and composition 1-5 3. Operation 6 4. Clearing of common faults

More information

A REVIEW OF THE MECHANICAL CLEANING OF EVAPORATORS

A REVIEW OF THE MECHANICAL CLEANING OF EVAPORATORS A REVIEW OF THE MECHANICAL CLEANING OF EVAPORATORS G R E LIONNET 1 and L A BLAIKIE 2 1 Tongaat-Hulett Sugar Ltd, Private Bag 3, Glenashley, 4002, South Africa 2 Tongaat-Hulett Sugar Ltd, Private Bag, Amatikulu,

More information

User s Information Manual

User s Information Manual 48TJD005-014 48TJE004-014 48TJF004-012 Single-Package Rooftop Heating/Cooling Units User s Information Manual NOTE TO INSTALLER This manual should be left with the equipment owner. FOR YOUR SAFETY Do not

More information

BOILER CLEANING SYSTEMS. for Improved Availability of Waste Incineration Boilers

BOILER CLEANING SYSTEMS. for Improved Availability of Waste Incineration Boilers BOILER CLEANING SYSTEMS for Improved Availability of Waste Incineration Boilers BOILER EFFICIENCY ENERGY RECOVERY MATERIALS HANDLING Clean Energy Solutions Range of Services for On-load Boiler Cleaning

More information

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. www.windsterhood.com User s Manual WS-63TB36SS WS-63TB42SS ISLAND SERIES NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed

More information

user s information manual

user s information manual user s information manual SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 580F Sizes 036-150 3 to 12 1 / 2 Tons Cancels: New OM11-18 10/15/00 NOTE TO INSTALLER This manual should be left with

More information

GETTING STARTED OPTIONAL HARDWARE A

GETTING STARTED OPTIONAL HARDWARE A ROLLER SHADES Continuous Cord Loop and Link System without Cassette Double Roller GETTING STARTED OPTIONAL HARDWARE A few simple tools are required: Hold Down Brackets Spacer Block Spacers Steel Tape Measure

More information

UNDER CABINET RANGE HOOD

UNDER CABINET RANGE HOOD UNDER CABINET RANGE HOOD MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS FOR DOMESTIC COOKING ONLY 1. Read all instructions before using the appliance 2. Install or locate this appliance

More information

Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark Phone: Internet: Fax:

Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark Phone: Internet:    Fax: Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark Phone: +45 45 81 23 00 Internet: www.gm.dk e-mail: gm@gm.dk Fax: +45 45 81 99 56 OPERATING INSTRUCTIONS FOR TF400 Folding Machine 2 Index

More information

USER S MANUAL. Fire Line Automatic 3. Manufactured by Planika Sp. z o.o. ul. Bydgoska Brzoza Poland. I0773#05 of

USER S MANUAL. Fire Line Automatic 3. Manufactured by Planika Sp. z o.o. ul. Bydgoska Brzoza Poland. I0773#05 of USER S MANUAL Fire Line Automatic 3 Manufactured by Planika Sp. z o.o. ul. Bydgoska 38 86-061 Brzoza Poland I0773#05 of 05.12.2014 Copyright Planika Sp. z o.o. www.planikafires.com 1 IT IS OBLIGATORY TO

More information