USER'S MANUAL PS

Size: px
Start display at page:

Download "USER'S MANUAL PS"

Transcription

1 USER'S MANUA PS ROOF FANS VENTS VKV \ VKH \ VKV EC \ VKH EC \ VKMK \ VKMKp \ VOK \ VOK SERIES

2 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK CONTENT. Application р.. Delivery set р.. Designation key р.. Basic technical data р Fan structure р Safety requirements р. 7. Installation and operation guidelines р. 8. Connection to power mains р Storage rules р Maintenance and servicing р. 8. Manufacturing warranty р.. Acceptance certificate р.. Warranty card р.

3 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK APPICATION The roof fans VENTS VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK in metal casing with intake flange diameter from 0 to 500 mm for all models and from 50 mm to 560 mm for VKV EC and VKH EC models, hereinafter referred to as fans, are designed for ventilation of various industrial premises, high-rise building and premises, public places, offices, hospitals, restaurants, pools and other premises heated during winter time. The fan is not designed for heavy-duty operation in the environment containing dust, solid particles, sticky and fibrious materials. The ambient temperature must not exceed the values stated in the tables 5; 7; 9; 0. The fan is suitable for vertical mounting on the exhaust ventilation shaft and is used for exhaust ventilation only. The fan is rated for continuous operation always connected to power mains. Ingress protection rating is IP X. DEIVERY SET The delivery set comprises: fan - pce; user's manual; packaging.

4 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK DESIGNATION KEY VKV, VKH, VOK fan structural designation key. XXX X X XXX Impeller diameter, mm: 00; 0; 5; 50; 80; 00; 0; 50; 55; 00; 50; 500 E - single-phase D - three-phase Number of electric motor phases:,, 6. Fan designation: VKV - centrifugal roof fan with vertical air discharge VKH - centrifugal roof fan with horizontal air discharge VOK - axial roof fan with horizontal air discharge VKV EC, VKH EC fan structural designation key. XXX XXX XX Motor type: EC - electronically commutated Impeller diameter, mm: 50; 80; 0; 55; 00; 50; 500; 560 Fan designation: VKV - centrifugal roof fan with vertical air discharge VKH - centrifugal roof fan with horizontal air discharge

5 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK VKMK, VKMKp, VOK fan designation key structure XXX XXX Impeller diameter, mm: 50; 00; 50; 5 Fan designation: VKMK - centrifugal roof fan with a round cover VKMKp - centrifugal roof fan with a round cover and a base plate VOK - axial roof fan with a round cover Designation key example: VKV E 80 - centrifugal roof fan with vertical air discharge, two-pole single-phase electric motor and Ø 80 mm impeller. VKV 80 EC - centrifugal roof fan with vertical air discharge, EC electric motor and Ø 80 mm impeller. VKH E 0 - centrifugal roof fan with horizontal air discharge, -pole single-phase electric motor and Ø 0 mm impeller. VKMK 00 - centrifugal roof fan with Ø 00 mm intake flange. VKMKp 50 - centrifugal roof fan with a base plate and Ø 50 mm intake flange. BASIC TECHNICA DATA Fan designation, their parameters and connecting dimensions are shown in tables ; ; ; ; 5; 6; 7; 8; 9; 0 and in figures ; ; ;.

6 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK VKV, VKV EC H D Figure Fan Тип type вентилятора VKV ВКВ Е 0 VKV ВКВ Е 5 VKV ВКВ Е 50 VKV ВКВ Е 80 VKV ВКВ Е 0 VKV D 0 ВКВ Д VKV ВКВ Е 55 VKV D 55 ВКВ Д VKV ВКВ Е 00 VKV D 00 ВКВ Д VKV ВКВ Е 50 VKV D 50 ВКВ Д VKV ВКВ 6Е 500 Dimensions, Размеры, мм mm ØD Н ØD Н Масса, Weight, kg кг 8,9 9,6,0,7 7,8 7,8,0,0 7,5 7,5 0,0 0,0,8 Table Fan type VKV 50 ЕС VKV 80 ЕС VKV 0 ЕС VKV 55 ЕС VKV 00 ЕС VKV 50 ЕС VKV 500 ЕС VKV 560 ЕС Table Dimensions, mm Weight, kg

7 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK VKH VKH EC d H H d D D Figure Fan type VKH Е 0 VKH Е 5 VKH Е 50 VKH Е 80 VKH Е 0 VKH D 0 VKH Е 55 VKH D 55 VKH Е 00 VKH D 00 VKH Е 50 VKH D 50 VKH 6Е 500 Dimensions, mm ØD ød Н Weight, kg 6,9 7, 0, 0, 0, 0, 5,6 5,6,0,0,7,7 6,6 Table Fan type VKH 50 ЕС VKH 80 ЕС VKH 0 ЕС VKH 55 ЕС VKH 00 ЕС VKH 50 ЕС VKH 500 ЕС VKH 560 ЕС Dimensions, mm ØD ød Н Weight, kg Table

8 8 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK Fan type Current, A VKV/VKH Е 0 VKV/VKH Е 5 VKV/VKH Е 50 VKV/VKH Е 80 VKV/VKH Е 0 VKV/VKH D 0 VKV/VKH Е 55 VKV/VKH D 55 VKV/VKH Е 00 VKV/VKH D 00 VKV/VKH Е 50 VKV/VKH D 50 VKV/VKH D 500 0,8 0,6 0,7,0 0,5 0,, 0,5, 0,7, 0,8,8 Power, W Voltage, V at 50 Hz Maximum operating temperature, C Y 0 00Y Table 5 ØD ØD VKMK VKMKp ø H H 0 ø ØD ØD Figure Fan type VKMK 50 VKMK 00 VKMK 50 VKMK 5 VKMKp 50 VKMKp 00 VKMKp 50 VKMKp 5 Table 6 Dimensions, mm ØD ØD H Weight, kg 7, 8, 0, 0, 8, 9,,,

9 9 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK Fan type Current, A Power, W Voltage, V at 50/60 Hz Maximum operating temperature, C VKV/VKH 50 ЕС VKV/VKH 80 ЕС VKV/VKH 0 ЕС VKV/VKH 55 ЕС VKV/VKH 00 ЕС VKV/VKH 50 ЕС VKV/VKH 500 ЕС VKV/VKH 560 ЕС,8,,5,,6,, ~ 0-77 ~ 0-77 ~ 0-77 ~ ~ ~ ~ ~ Table 7 ØD VOK ØD VOK 0 H 0 ø H ø ØD ØD Figure Fan type VOK Е 00 VOK Е 50 VOK Е 50 VOK Е 00 VOK Е 00 VOK Е 50 VOK 00 VOK 50 VOK 5 Dimensions, mm ØD ØD H Weight, kg, 6,5 6,5 8,7 8,7 0,9,9 6,8 9, Table 8

10 0 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK Fan type Current, A Power, W Voltage, V at 50/60 Hz Maximum operating temperature, C VKMK/VKMKp 50 0, VKMK/VKMKp 00 0, VKMK/VKMKp 50 0, VKMK/VKMKp 5, Table 9 Fan type Current, A Power, W Voltage, V at 50 Hz Maximum operating temperature, C VOK Е 00 0, VOK Е 50 0, VOK Е 50 0, VOK Е 00 0, VOK Е 00 0, VOK Е 50 0, VOK 00 0, VOK 50 0, VOK 5 0, Table 0 FAN STRUCTURE The centrifugal fan VKV/VKV EC (fig. ) consists of the pan connected through a net to the base with the fixed electric motor and impeller on it. The VKV EC fan is equipped with EC motor. The protecting housing is also fixed to the pan. The cover that protects the electric motor against weather factors is fixed to the base. The terminal box is fixed to the upper casing part for connection of the fan to single- or three-phase power mains and placement of the operating capacitor.

11 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK The centrifugal fan VKH/VKH EC (fig. ) consists of the pan connected through a net to the base with the fixed electric motor and impeller on it. The VKH EC fan is equipped with a EC motor. The cover that protects the electric motor against weather factors is fixed to the base. The terminal box for connection of the fan to single- or three-phase power mains and placement of the operating capacitor is fixed to the upper casing part. The centrifugal roof fan VKMK/VKMKp (fig. ) consists of the casing and the flange. The impeller and the electric motor are placed inside the fan casing. The cover is attached to the casing with self-tapping screws. The terminal box for connection of the fan to single- or three-phase power mains and placement of the operating capacitor is fixed to the upper casing part. The axial fan VOK/VOK (fig. ) consists of the casing with a square flange (VKMK modification) or a plate (VKMKp modification). The impeller and the electric motor are placed inside the axial fan casing. The cover is attached to the casing with self-tapping screws. The terminal box for connection of the fan to single- or three-phase power mains and placement of the operating capacitor is fixed to the upper casing part. SAFETY REQUIREMENTS All electric connection, adjustment, servicing and repair operations must be done with the fan disconnected from power supply. Electric connection works must be done by a duly qualified electrician with a valid electrical work permit for operation up to 000 V units. Read this manual before starting any electrical works. Make sure of no visible damages of impeller, casing, grille and no foreign objects inside the casing that can damage the impeller blades. Misuse of the fan and any unauthorized modifications are not allowed. The unit is not to be used by children and persons with reduced physical, mental or sensory capacities, without proper practical experience or expertise, unless they are controlled or instructed on the unit operation by the person(s) responsible for their safety. The fans are not designed for operation in the environment containing flammable substances or vapours like alcohol, gasoline, etc. The fans are powered by single-phase 0 V/ 50 Hz (VKMK and VKMKp 0 V/ 50 Hz, 60 Hz) alternating current or by three-phase 00 V/ 50 Hz alternating current.

12 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK INSTAATION AND OPERATION GUIDEINES The fan is designed for mounting on a roof directly above a ventilation shaft or air duct. Installation procedure and mounting sequence are shown in fig. 5, 6, 7, 8, 9, 0. To prevent water and snow ingress inside a ventilation shaft the fan can be mounted on a roof curb. A roof fan can be connected to a ventilation shaft with an intake flange that is fixed directly to the fan base. The fan base has holes for fastening bolts for connection of the fan to the level surface or to the roof curb. The roof curb, intake flange and fastening bolts are not included into delivery set and are available upon separate order. Power supply to the fan is effected with an external terminal box or a terminal block integrated into the motor casing. The fan must be grounded. The terminal must be connected to the ground loop. Due to the constant improvements the design of some models may slightly differ from those described in this manual.

13 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK VKV, VKV EC Figure 5

14 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK VKH Figure 6 VKH EC Figure 7

15 5 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK VKMK Figure 8 VKMKp Figure 9

16 6 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK VOK, VOK Figure0 CONNECTION TO POWER MAINS Switch power supply off before starting any operations with the fan. Connection to power supply must be done by a duly qualified electrician. The rated electrical parameters are shown on the rating plate. Any tampering with the internal connection is prohibited and will void warranty. Depending on the modification the fans are powered by single-phase 0 V / 50 Hz or 60 Hz or 00 V / 50 Hz alternating current. The fan must be connected through insulated durable and thermal-resistant wires (cables). The automatic circuit breaker incorporated into the fixed power network that breaks all the phases must be installed at the external electric input 0 V / 50 Hz or 60 Hz or 00 V / 50 Hz. The external circuit breaker location must provide free and unhampered access to the fan for quick switching off in case of need. The overcurrent protection must match the rated current consumption Of the fan.

17 7 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK The recommended automatic circuit breaker rated current and the cable cross sections for various fan types are stated in the table. The above cross sections are for reference only. The actual cross section depends on the cable type, maximum heating value. The fans with EC-motors are connected to power mains through the terminal block located inside the external or integrated terminal block in compliance with the wiring diagram and the terminal designation, see fig. 7 for VKV/VKH 50 0 EC; fig. 8 for VKV/VKH EC. The terminal designations are shown on the sticker inside the terminal box. The recommended wiring diagram with motor overheating protection for singlephase motor is shown in fig. and for three-phase motor is shown in fig.. TW and TW terminals are the electrical leads of the normally closed contact of the motor overheating protection. This contact must be connected in series to the power circuit of the coil of the magnetic starter KM that starts the motor after pressing the button S. The contact is broken in case of motor overheating and it switches the starter coil off to cut power supply to the motor off. The automatic circuit breaker, magnetic starter KM, control buttons S and S are not included into the delivery set and are designed to be installed by the user. Fan type Automatic circuit breaker rated current, A Recommended cable, n x S, where n - number of the cable conductors S - the cable cross section, mm VKV/VKH Е VKV/VKH Е 0 х0,5 VKV/VKH Е 80 VKV/VKH Е 55,6 х0,5 VKV/VKH Е х,0 VKV/VKH 6Е 500,5 х,0 VKV/VKH D х0,5 VKV/VKH ЕС х,0 VKV/VKH ЕС 5х0,75 VKV/VKH ЕС 0 5х,5 VKMK/VKMKp х0,5 VKMK/VKMKp 5 х0,5 VOK Е, Е х0,5 VOK х0,5

18 8 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK X KM ~0V 50Hz РЕ N N PE S ON TW 5 TW 6 S OFF Figure KM X ~00V 50Hz PE S ON S OFF N Figure PE TW TW

19 9 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK Wiring diagram for VKV/VKH E 0; VKV/VKH E 5; VKV/VKH E 50; VKV/VKH E 80, VKV/VKH E 0, VKV/VKH E 55 fans. ~0 V 50 Hz N X РЕ N PE where is the automatic circuit breaker (not included into the delivery set); X is the terminal block. Figure Wiring diagram for VKV/VKH E 00; VKV/VKH E 50; VKV/VKH 6E 500 fans. ~0 V 50 Hz N PE TW TW X РЕ N TW TW 5 6 where is the automatic circuit breaker (not included into the delivery set); X is the terminal block. Figure

20 0 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK Wiring diagram for VKV/VKH D 0 fan. X ~00 V 50 Hz PE РЕ where is the automatic circuit breaker (not included into the delivery set); X is the terminal block. Figure 5 Wiring diagram for VKV/VKH E 55 fan; VKV/VKH D 00; VKV/VKH D 50 fans. ~00 V 50 Hz PE X TW TW U V W U 5 V 6 W РЕ 7 PE TW 8 TW TW 9 TW where is the automatic circuit breaker (not included into the delivery set); X is the terminal block. Figure 6

21 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK Wiring diagram for VKV/VKH 50 EC; VKV/VKH 80 EC; VKV/VKH 0 EC fans. Cable Contact Connection Cable Colour Black Blue Green/Yellow Function Network 50/60 Hz, phase Network 50/60 Hz, zero wire protective ground conductor White failure relay, normally closed contact White failure relay, COMMON Red Voltage output +0 V (no more. ma) Yellow Control input 0-0 V / PWM (full resistance 00 kohm) Blue Ground Figure 7 Wiring diagram for VKV/VKH 55 EC, VKV/VKH 00 EC, VKV/VKH 50 EC, VKV/VKH 500 EC, VKV/VKH 560 EC fans. Terminal Connection Function protective ground conductor Terminal Connection Function alarm relay, normally closed contact alarm relay, COMMON (A, 50 V, AC) control signal output 0-0 V max. ma GROUND (GND) control input (full resistance 00 kohm) External potentiometer power supply, 0 V (+0%) max. 0 ma External sensor power supply 0 V (+0%) max. 50 ma alarm relay, normally open contact control input control input GROUND (GND) interface RS85 for ebmbus; RS B interface RS85 for ebmbus; RS A interface RS85 for ebmbus; RS B interface RS85 for ebmbus; RS A Figure 8

22 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK Wiring diagram for VKMK/VKMKp 50; VKMK/VKMKp 00; VKMK/VKMKp 50; VKMK/VKMKp 5 fans. X ~0 V РЕ 50/60 Hz N PE N where is the automatic circuit breaker (not included into the delivery set); X is the terminal block. Figure 9 Wiring diagram for VOK E 00; VOK E 50; VOK E 50; VOK E 00; VOK E 00; VOK E 50 fans. X ~0 V РЕ 50 Hz N N PE where is the automatic circuit breaker (not included into the delivery set); X is the terminal block. Figure 0 Wiring diagram for VOK 00; VOK 50; VOK 5 fans. X ~0 V РЕ 50 Hz N N PE where is the automatic circuit breaker (not included into the delivery set); X is the terminal block. Figure

23 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK VKH 5 6 Figure

24 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK VKH EC 5 Figure

25 5 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK VKV, VKV EC 5 6 Figure

26 6 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK VKMK, VKMKp Figure 5 5 6

27 7 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK VOK, VOK Figure 6 STORAGE RUES Store the fan in manufacturer s packaging in a ventilated room at temperatures between +5 С and +0 С and relative humidity not more than 80% (at +0 С)

28 8 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK MAINTENANCE AND SERVICING Fan maintenance means periodic cleaning of the surfaces from dust and dirt. Switch the fan off while doing any maintenance operations! Use a dry soft brush or compressed air to remove dust. The impeller blades require thorough cleaning at least once in 6 months. To clean the soiled fan internal parts perform a partial fan dismantling. Wash the fan blades carefully with mild detergent and water solution avoiding liquid penetration on the electric motor. VKH Figure 7

29 9 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK VKH EC Figure 8 VKV, VKV EC Figure 9

30 0 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK VKMK, VKMKp Figure 0 VOK, VOK Figure

31 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK MANUFACTURING WARRANTY While buying the present product the Customer agrees to accept the following warranty conditions: The manufacturer guarantees normal performance of the ventilation unit for months from the date of resale, subject to the compliance with transport, storage, mounting and operation rules. In case of no confirmation of the sales date the guarantee period is calculated from the manufacturing date. All the units and components belonging to the faulty unit and replaced within the warranty period shall be covered by the previous warranty period and general warranty conditions. Thus the warranty period is neither extended nor renewed for the replaced components or the unit. In case of failure due to faulty equipment during the warranty period the consumer has the right to get it exchanged at the manufacturing facility. The accessories operated together with the unit, both included and not included into the delivery list as well as other equipment operating jointly with the unit are not covered by the warranty. The company is not responsible for compatibility of their goods with other producers' goods. The warranty covers the manufacturing defects only. All the defects and faults resulting from gross mechanical effect during operation process or natural wear-and-tear are not covered by the warranty conditions. The faults caused by violence of operation, servicing and maintenance guidelines either by Customer or third parties or caused by unauthorized design modifications shall not be covered by warranty. NO IABIITY FOR THE REATED DAMAGES: The manufacturer is not responsible for any mechanical or physical damages resulting from the manual requirements violence, the unit misuse or gross mechanical effect. Indirect damages such as re-installation or re-connection of the unit, direct or indirect losses related to the unit replacement shall not be indemnified. Mounting/dismantling, connection/disconnection and adjustment of the unit shall not be covered by the warranty. The contractor for mounting, electric mounting and adjustment works shall be responsible for quality and warranty of these works. In any case the indemnity amount shall not exceed the actually paid value for the defective unit price.

32 VKV, VKH, VKV EC, VKH EC, VKMK, VKMKp, VOK, VOK ACCEPTANCE CERTIFICATE We hereby declare that the following product complies with the essential protection requirements of Electromagnetic Council Directive 00/08/EC, 89/6/EEC and ow Voltage Directive 006/95/EC, 7//EEC and CE-marking Directive 9/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. The fan has been duly certified as serviceable Model VENTS VKV VKH VKV EC VKH EC VKMK VKMKp VOK VOK (tick the proper model only) Manufacturing date Approval mark Sold by (name of trading enterprise, stamp of the shop) Date of sale WARRANTY CARD V-///EN-06

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS / Z / VC SERIES 2 / z / VC CONTENT Use Delivery set Structural designation key Main technical data Safety requirements Fan design Connection

More information

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11 OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES F88EN-02.indd 1 04.09.2015 8:07:11 2 VKM ЕС CONTENT Introduction Use Structural designation key Delivery set Main

More information

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING USER S MANUAL VCU/ Series CENTRIFUGAL FAN IN SCROLL CASING 2 CONTENTS Introduction Use Delivery set Designation key Technical data Safety requirements Design and operating logic Mounting and set-up Connection

More information

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL. IIE MIXED-FOW FAS VETS TT SERIES USER'S MAUA www.ventilation-system.com 2011 Read this manual carefully before installation and commissioning of the unit.! READ THE ISTRUCTIOS CAREFUY TO REDUCE THE RISK

More information

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL INLINE CENTRIFUGAL FAN OPERATION MANUAL www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 4 Fan design 4 Delivery

More information

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL CENTRIFUGAL FAN IN SCROLL CASING Helix S-Vent EN OPERATION MANUAL Helix / S-Vent www.blaubergventilatoren.de CONTENTS CONTENTS 3 Introduction 3 Use 3 Delivery set 4 Technical data 10 Safety requirements

More information

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL CONTENT 3 Introduction 3 General 3 Safety rules 3 Storage and transportation rules 3 Manufacturer s warranty 4 Fan design 4 Delivery set 5 Technical data

More information

AXIAL FANS USER S MANUAL

AXIAL FANS USER S MANUAL AXIAL FANS USER S MANUAL WARNING! Disconnect the fan from power supply prior to any connection, servicing and repair operations. Only duly qualified electricians with valid electrical permit for electric

More information

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59 SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery

More information

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL TUBO-M/MZ AXIS-QA AXIS-Q TUBO-F AXIS-QR AXIS-F AXIS-QRA AXIS-QA G AXIAL FANS EN OPERATION MANUAL www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements

More information

USER'S MANUAL INLINE CENTRIFUGAL FANS IN SOUND-INSULATED CASING VS, VS EC SERIES

USER'S MANUAL INLINE CENTRIFUGAL FANS IN SOUND-INSULATED CASING VS, VS EC SERIES USER'S MAUA IIE CETRIFUGA FAS I SOUD-ISUATED CASIG VS, VS EC SERIES PURPOSE The inline centrifugal fan VS / VS EC enclosed in a sound-insulated casing with the intake spigot diameter from up to 70 mm,

More information

USER S MANUAL. VKP Series INLINE FAN

USER S MANUAL. VKP Series INLINE FAN USER S MANUAL Series INLINE FAN 2 CONTENTS Safety requirements 3 Introduction 5 Use 5 Delivery set 5 Designation key 5 Technical data 5 Design and operating logic 8 Mounting and set-up 8 Connection to

More information

Wind. Service instruction

Wind. Service instruction Wind Service instruction E BAUBERG Company is happy to offer your attention the window axial Blauberg Wind fan. The solid team of high-qualified professionals with many years of working experience, technological

More information

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315 USER S MANUAL VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125 VKMz 150 VKMz 160 VKMz 200 Q VKMz 200 VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315 Centrifugal inline fan VKMz CONTENTS Contents... 2 Safety requirements...

More information

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable Smart Smart IR model (check applicable) is recognized as serviceable Service instruction SALES DATE MANUFACTURED ON (DATE): SOLD APPROVAL MARK SMART-EN-04 BLAUBERG Company is happy to offer your attention

More information

Centrifugal inline fans

Centrifugal inline fans USER S MANUAL VKM 100 Q VKM 100 VKM 125 Q VKM 125 VKM 150 E VKM 150 VKMS 150 VKM 160 VKMS 160 VKM 200 VKMS 200 VKM 250 E VKM 250 VKM 315 VKMS 315 VKM 355 Q VKM 400 VKM 450 Centrifugal inline fans VKM CONTENTS

More information

Turbo. Service Instructions

Turbo. Service Instructions Turbo Service Instructions E BAUBERG Company is happy to offer your attention a new highquality inline mixed-flow Blauberg Turbo fan. The solid team of highqualified professionals with many years of working

More information

CENTRIFUGAL FANS user's manual. model VENTS VK.

CENTRIFUGAL FANS user's manual. model VENTS VK. EN CENTRIFUGAL FANS user's manual model VENTS VK www.ventilation-system.com 2013 EN! WARNING! Disconnect the fan from power mains prior to any connection, servicing and repair operations. Mounting and

More information

HEAT RECOVERY AIR HANDLING UNIT

HEAT RECOVERY AIR HANDLING UNIT HEAT RECOVERY AIR HANDLING UNIT OPERATION MANUAL KOMFORT_L v2(2)_en.indd 1 07.08.2015 15:0:44 CONTENTS Introduction General Safety regulations Transportation and storage regulations Manufacturer's warranty

More information

Aero. Service Instructions

Aero. Service Instructions Aero ervice Instructions E BAUBERG Company is happy to offer your attention a new generation product, the BAUBERG Aero fan. The solid team of highqualified professionals with many years of working experience,

More information

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL IIE MIED FOW FAS I SOUD ISUATED CASIG VETS TT SIET M USER MAUA www.ventilation-system.com 2013 ! WARIG Disconnect the fan from power mains prior to any connection, servicing and repair operations. Mounting

More information

INTELLIGENT AXIAL FAN user's manual

INTELLIGENT AXIAL FAN user's manual ACCEPTANCE CERTIFICATE The fan is duly recognized as serviceable. ifan Approval mark Manufactured on (date) Sold (name and stamp of the trade company) INTELLIGENT AXIAL FAN user's manual model VENTS ifan

More information

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300 USER S MANUAL Heat Recovery Ventilator Vents Brig HRV 200 Vents Brig HRV 300 2 Brig HRV 200 (300) CONTENT Introduction... 3 Application... 3 Delivery set... 3 Unit designation key... 4 Basic unit dimensions...

More information

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC USER MANUAL Air handling unit with heat recovery VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC 2 CONTENTS Introduction Use Delivery set Structural designation key Technical

More information

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S USER S MANUAL Heat (Energy) Recovery Ventilator Vents Frigate HRV 120 S Vents Frigate ERV 120 S 2 Frigate HRV(ERV) 120 S CONTENT Introduction... 3 Application... 3 Delivery set... 3 Unit designation key...

More information

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

AXIAL FAN User s manual. Quiet-dMEV 100 DC. AXIAL FAN User s manual Quiet-dMEV 100 DC www.ventilation-system.com CONTENTS Delivery set... 6 Brief description... 6 Operating guidelines... 6 Designation key... 7 Installation and set-up... 7 Fan options...

More information

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT S S11 Series SB S11 Series SB -E S11 Series SB -E S11 Series EN OPERATION MANUAL CONTENTS Safety requirements... 2 Purpose... 4 Delivery set...

More information

HEAT RECOVERY VENTILATOR

HEAT RECOVERY VENTILATOR HEAT RECOVERY VENTILATOR HRV H 00 ERV H 00 HRV H 300 ERV H 300 EN OPERATION MANUAL HRV /ERV H 00(300) www.blaubergventilatoren.de CONTENTS Application... Delivery set...3 Unit designation key...3 Basic

More information

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL SOUND-INSULATED FAN Iso-B EN OPERATION MANUAL Iso-B www.blaubergventilatoren.de CONTENTS Safety requirements... 3 Introduction... 5 Purpose... 5 Delivery set... 5 Technical data... 6 Design and operating

More information

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 EN OPERATION MANUAL CONTENTS Introduction 3 General 3 Safety rules 3 Transportation and storage rules 3 Manufacturer's warranty 3

More information

CENTRIFUGAL CEILING EXTRACT FAN

CENTRIFUGAL CEILING EXTRACT FAN CENTRIFUGAL CEILING EXTRACT FAN 110 Т/H/IR 110 Light Т/H/IR 150 Т/H/IR 150 Light Т/H/IR EN USER'S MANUAL CONTENTS Contents... 2 Safety requirements... 2 Purpose... 4 Delivery Set... 4 Designation key...

More information

CENTRIFUGAL CEILING EXTRACT FAN

CENTRIFUGAL CEILING EXTRACT FAN CENTRIFUGAL CEILING EXTRACT FAN Ceileo 200/250/300 Ceileo 200/250/300 Т/H/IR Ceileo 200/250/300 Light Ceileo 200/250/300 Light Т/H/IR EN USER'S MANUAL CONTENTS Safety requirements... 2 Purpose... 4 Delivery

More information

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control USER S MANUAL Duct heater for supply air pre-heating with external control CONTENTS Contents... 2 Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Design

More information

Calm. Service Instructions

Calm. Service Instructions Calm E ervice Instructions BAUBERG VETIATORE GmbH is happy to offer you a new generation product, the BAUBERG Calm fan. The solid team of high-qualified professionals with many years of working experience,

More information

AXIAL FANS user's manual. model Quiet

AXIAL FANS user's manual. model Quiet E AXIA FA user's manual model Quiet 0 ! WARIG Disconnect the fan from power mains prior to any connection, servicing and repair operations. Mounting and maintenance are allowed for duly qualified electricians

More information

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit USER S MANUAL Air duct heater with integrated temperature control unit or a control unit 2 CONTENTS Safety requirements 3 Introduction 5 Use 5 Delivery set 5 Designation key 5 Main technical parameters

More information

AXIAL DOMESTIC FANS. User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION

AXIAL DOMESTIC FANS. User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION AXIAL DOMESTIC FANS User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION SAFETY REQUIREMENTS Disconnect the fan from power mains prior to any connection, servicing and repair operations.

More information

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT РУКОВОДСТВО USER S MANUAL ПОльзователя VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT 2 CONTENTS Safety requirements 3 Introduction 5 Use 5 Delivery set 5

More information

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT EN OPERATION MANUAL www.blaubergventilatoren.de CONTENTS 3 Introduction 3 General 3 Safety rules 3 Transportation and storage rules 3 Manufacturer's warranty

More information

USER S OPERATION MANUAL HL-RD 2000 E EC HL-RD 3000 E ЕС

USER S OPERATION MANUAL HL-RD 2000 E EC HL-RD 3000 E ЕС USER S OPERATION MANUAL HL-RD 2000 E EC HL-RD 3000 E ЕС Air handling unit with heat recovery 2 CONTENT Introduction Use Delivery set Structural designation key Technical data Safety precautions Structure

More information

Series VENTS VUT R WH ЕС

Series VENTS VUT R WH ЕС AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS EH ЕС Series VENTS WH ЕС Air handling units with the air capacity up to 1500 m 3 /h in soundand heat-insulated casing with integrated electric heater.

More information

USER S MANUAL DN-2. Drain pump

USER S MANUAL DN-2. Drain pump USER S MANUAL DN-2 CONTENTS Safety requirements... 2 Purpose... 3 Delivery set... 3 Technical data... 3 Design... 4 Installation and set-up... 5 Connection to power mains... 8 Storage and transportation

More information

DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29

DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29 DUCT COOLERS KWK KFK EN OPERATION MANUAL KWK_KFK_v2(4)_EN.indd 1 13.06.2016 13:35:29 CONTENTS 3 Introduction 3 General 3 Safety rules 3 Transportation and storage regulations 3 Manufacturer s warranty

More information

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2 USER'S MANUAL TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2 TwinFresh S-60 TwinFresh SA-60 TwinFresh S-60-2 TwinFresh SA-60-2 TwinFresh S-50 TwinFresh SA-50 TwinFresh S-50-2 TwinFresh

More information

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14 Heat/heat and humidity recovery air handling unit CONTENTS Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5

More information

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT 2 CONTENTS. Safety requirements... 3 Introduction.........................................................

More information

Installation manual Mini Comfort 50 S/L 07/ V EN

Installation manual Mini Comfort 50 S/L 07/ V EN Installation manual Mini Comfort 50 S/L 07/2015 - V 1.1 - EN www.veneco-ventilation.be Veneco ventilation by Elek Trends Productions nv Blauwfazantjesstraat 4 B - 7700 Moeskroen Tel. +32 (0)56 48 15 90

More information

Air handling unit. BlauAir RH USER S MANUAL

Air handling unit. BlauAir RH USER S MANUAL Air handling unit EN USER S MANUAL CONTENTS Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Unit design and operation logic... 7 Installation and set-up...

More information

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW 90411215-Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW DESTINATION The in-line mixed flow fans with channels' diameters ranging from 100 to 150 mm are designed for installation in the ventilating systems

More information

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit USER MANUAL Frigate HRV 120 SR Frigate ERV 120 SR Heat (energy) recovery ventilation unit 2 CONTENTS Safety requirements... 3 Introduction... 5 Use... 5 Included in the box... 5 Designation key... 5 Technical

More information

Axial intelligent fan USER S MANUAL

Axial intelligent fan USER S MANUAL Axial intelligent fan USER S MANUAL CONTENTS Delivery set... 6 Technical data... 6 Installation and set-up... 9 Connection to power mains... 11 Operation guidelines... 11 Unit control... 12 Storage and

More information

AIR HANDLING UNIT WITH HEAT RECOVERY

AIR HANDLING UNIT WITH HEAT RECOVERY AIR HANDLING UNIT WITH HEAT RECOVERY Freshbox 100 EN OPERATION MANUAL Freshbox 100 www.blaubergventilatoren.de CONTENTS Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical

More information

Operating instructions

Operating instructions ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 793-0 Fax +49 (0) 793-0 info@de.ebmpapst.com www.ebmpapst.com CONTENTS. SAFETY REGULATIONS AND NOTES. Levels of hazard warnings.

More information

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15 HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15 EN OPERATION MANUAL KOMFORT EC S/SB www.blaubergventilatoren.de CONTENTS 3 Introduction 3 General 3 Safety regulations 3 Transportation

More information

HEAT RECOVERY AIR HANDLING UNITS

HEAT RECOVERY AIR HANDLING UNITS HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC DB S11 KOMFORT EC DB S15 EN OPERATION MANUAL KOMFORT_EC_DB_S11(15)_v2(2-4)_ENG.indd 1 06.08.2015 14:30:31 CONTENTS 3 Introduction 3 General 3 Safety regulations

More information

Micro-Computer Induction Cooktop SR-1885SS

Micro-Computer Induction Cooktop SR-1885SS Micro-Computer Induction Cooktop SR-1885SS INSTRUCTION MANUAL Thank you for your purchase. Please read thoroughly before initial use and keep in a safe place for future reference. INDEX Important safeguards....

More information

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 HG 675 X 60 HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 1 2 1. : 93/68: 90/396: 2006/95/CE: 2004/108/CE: - 1935/2004:. 2002/95/CE: RoHS 2.,.,,,,...,. (,..)..,,.,. ( ),,, ;,,.,.....,.,,,,,,...,. (..),,.,..,.,,,,

More information

OSC... INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD

OSC... INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD OSC... INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD EN min 450mm Electrical cookers min 650mm Gas cookers min 650mm Gas cookers 1a 1b 1c 2a 2b ELECTRICAL / GAS - 650mm 3a 3b 2 2 x 8 3c 3d 3e 3 0 1 2 3 L

More information

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual. IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125 EN User`s manual www.vents-us.com EN READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY, READ AND UNDERSTAND

More information

IN 900 BIC UK INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD

IN 900 BIC UK INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD IN 900 BIC UK INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD EN Before using the appliance, please carefully read this manual! 2 3 min 450mm Electrical cookers min 650mm Gas cookers min 650mm Gas cookers

More information

Operation Manual. Automatic Control System for Air Supply Ventilation Unit with Hydronic Coil Heat Exchanger

Operation Manual. Automatic Control System for Air Supply Ventilation Unit with Hydronic Coil Heat Exchanger Operation Manual PA 01W PA 02W PA 03W PA 04W Automatic Control System for Air Supply Ventilation Unit with Hydronic Coil Heat Exchanger 2 PA W Contents General description Technical Specifications Safety

More information

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС HEAT RECOVERY AIR HANDLING UNITS Series VUT R TN H ЕС VUT R TN EH ЕС HEAT-RECOVERY VENTILATION Two-Stage Energy Saving System: HEATING COOLING Stage 1: Heat energy recovery by means of the rotary heat

More information

Duct electric heater with temperature controller

Duct electric heater with temperature controller HEATERS Series Series U Duct electric heater Duct electric heater with temperature controller Duct electric heater with a control unit Applications Duct electric heater are designed for supply air heating

More information

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance...

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance... Table of Contents Forward... 3 Quality Policy... 3 Design Parameters... 4 Section A Unit Operation... 5 Section B Unit Maintenance... 6 Trouble Shooting Guide... 6 Wiring Diagram... 7 Section C Unit Installation...

More information

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Mobile Air Conditioner Instruction Manual Model TC-N9KM Mobile Air Conditioner Instruction Manual Model TC-N9KM Please read and retain these instructions for future reference SPECIFICATION Model no. Cooling capacity Power/Ampere consumption for cooling* Air

More information

BIG BEAR VORTEX FAN MODEL #BB-2

BIG BEAR VORTEX FAN MODEL #BB-2 OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-2 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING PLEASE READ AND SAVE THESE INSTRUCTIONS MODEL #BB-2 YOUR NEW BIG BEAR

More information

Safety and Instruction Manual

Safety and Instruction Manual T14002 Safety and Instruction Manual PLEASE READ CAREFULLY 30cm Ceramic Coated Electric Sauté Pan T14002 30cm Ceramic Coated Electric Sauté Pan TECHNICAL DATA Description: Model: Rated Voltage: Input power:

More information

MANUAL INTELLIVENT CELSIUS

MANUAL INTELLIVENT CELSIUS MANUAL INTELLIVENT CELSIUS EN Thank you for choosing this product from Simx. Before installing and using the fan, read through these instructions. Keep them safe for reference in future. SPECIFICATIONS

More information

Installation and Operating Instructions. Models: T4-12LOW-9IS

Installation and Operating Instructions. Models: T4-12LOW-9IS Installation and Operating Instructions Models: T4-12LOW-9IS Dear Valued Customer, Thank you and congratulations on purchasing your new Parmco appliance. All Parmco products are made to the highest quality

More information

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING 12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING This manual contains very important safety warnings and information. Read and save these instructions for future

More information

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX. RG CPAP 24 V mit Powermodul 24V sensorless

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX. RG CPAP 24 V mit Powermodul 24V sensorless Operating manual RG CPAP 24 V mit Powermodul 24V sensorless 1 SAFETY REGULATIONS AND INFORMATION Read the operating manual carefully before commencing work at the product. Pay attention to the following

More information

EH1210. airooncentre.co.uk. Peltier Dehumidifier Déshumidificateur Peltier. The Award Winning Ventilation Specialists

EH1210. airooncentre.co.uk. Peltier Dehumidifier Déshumidificateur Peltier. The Award Winning Ventilation Specialists EH1210 Peltier Dehumidifier Déshumidificateur Peltier IMPORTANT Installer and Users please note: These instructions should be read carefully and left with the user of the product for future reference.

More information

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS Please leave this instruction booklet with the pump as it contains maintenance and safety information (Original Instructions) MODELS This operating manual covers

More information

Quest Power Electric Heat EHS 62 Pro

Quest Power Electric Heat EHS 62 Pro Quest DRY Power 150 Electric Heat EHS 62 Pro Read and Save These Instructions The Quest Power Electric Heat EHS 62 Pro portable, heavy duty electric heater features multiple power receptacles for connection

More information

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units. AIR HANDLING UNITS WITH HEAT RECOVERY Series VUT PE EC Series SAS908 control panel SAS908 control panel Ceiling mounted energy saving Air Handling Units (AHU) with the air capacity up to 4000 m 3 /h and

More information

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual Version 1.5 1 CONTENTS CHAPTER 1 GENERAL INTRODUCTION...3 1. Preface... 3 2. Product Introduction... 3

More information

Quest PowerHeat HFC 100 Pro

Quest PowerHeat HFC 100 Pro Quest PowerHeat HFC 100 Pro Installation, Operation and Maintenance Instructions Read and Save These Instructions This manual is provided to acquaint you with the portable fan coil so that installation,

More information

Electric Garage Heater

Electric Garage Heater Electric Garage Heater G56 OWNERS MANUAL Read and save these instructions. A Name You Can Trust Trust has to be earned and we will earn yours. Customer happiness is the focus of our business. 2 From the

More information

USER'S MANUAL. Micra 150 HEAT RECOVERY UNIT

USER'S MANUAL. Micra 150 HEAT RECOVERY UNIT USER'S MANUAL Micra 150 HEAT RECOVERY UNIT 2 Micra 150 CONTENTS Introduction Use Included in the Box Designation Key Example Technical data Safety requirements DESIGN AND OPERATION Mounting and Installation

More information

MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION

MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION Do Žlábku 733, 514 01 Jilemnice Subject: MTP (MTPAL) Technical Documentation Page 1 of 13 MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION Table of Contents: Page: 2 Warranty Certificate 3 Quality and Completeness

More information

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

Inline mixed-flow fans with the air capacity up to 450 m 3 /h FANS FOR ROUND DUCTS Series VENTS ТТ PRO Series VENTS ТТ perform required servicing. All the models may be equipped with a regulated timer with turn-off delay adjustable from 2 to 30 min. TT PRO design

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS eturboprop High Pressure Axial Fans Installation and Wiring Instructions Stock Ref. 45012 50012 56012 63012 45032 50032 56032 63032 PLAS RAD ISTRUCTIOS I COJUCTIO WITH TH ILLUSTRATIOS. PLAS SAV THS ISTRUCTIOS

More information

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS NO RFEC/U/2017-1 (EN) (valid since 18.08.2017) ROOF FANS RF/EC...-... / RFV/EC...-... Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the

More information

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS TSEK VENCO Havalandırma ve Makina San.ve Tic. A.Ş. 2004. Cad. No:5 45400 OSB Turgutlu MANISA / TURKİYE Tel: +90 (236) 332

More information

Original instructions. Infrared heater IRCF...17

Original instructions. Infrared heater IRCF...17 Original instructions Infrared heater SE...7 NO...9 GB...11 DE...13 FR...15 RU...17 Fig. 1 Fig. 2 2 Fig. 3 3 Technical specifications Infrared heater 3 Type Heat output (1) [W] Voltage (2) Amperage (3)

More information

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS PW1370TD 2 EN Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS 3 E3 E1 C3 A1-A2-A3-A4 B4 B1 B5 B2 C1 B3 D 1 4 1 2 3 4 5 6 7 Ø13

More information

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON EL. PROTON EL Electric heating.

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON EL. PROTON EL Electric heating. OPERATIONS MANUAL FOR AIR HEATER PROTON EL ErP 2015 05010416 05022916 PROTON EL Electric heating Safety precautions Construction and dimensions Technical parameters Installation EN RU www.protongroup.org

More information

WOK-LINE INDUCTION RANGES. Installation and Operation Manual

WOK-LINE INDUCTION RANGES. Installation and Operation Manual WOK-LINE INDUCTION RANGES Wok-Line TYPE: 3500, 5000 Accessories Wok pan Installation and Operation Manual S/N: Rev.: 2.0 Dear Customer, Congratulations on deciding to choose a Metos appliance for your

More information

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

Microbox DC Models MBOX 125/2DC MBOX 125/2DC204 "Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204 Continuous Mechanical Extract Ventilation Unit with Low Energy DC Motor - for domestic and commercial use Installation, Operating and Maintenance Instructions

More information

INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS

INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS www.colorato.net INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS MODELS: CLHR-150A / CLHR-180A / CLHR-240A / CLHR-320A Read carefully this manual before using the appliance and keep them for future

More information

READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS

READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS Bifurcated Axial Fan Installation and Wiring Instructions 220-240V/1/50Hz & 380-415V/3/50Hz RAD INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLAS SAV THS INSTRUCTIONS Installation and Wiring Instructions

More information

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle! Trumatic E 7 7 2 9 9 4 Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7 To be kept in the vehicle! Trumatic E 2400 (Australia) Table of contents Installation example...

More information

GLEB Kitchen exhaust fan

GLEB Kitchen exhaust fan GLEB Kitchen exhaust fan Installation and Maintenance??.1.2013 Contents 1. Important information 2. Safety notes 3. Technical description 4. Transport 5. Mounting instructions 6. Commissioning 7. Maintenance

More information

Split Portable Air Conditioner

Split Portable Air Conditioner SP-IOM-1 Please read and save this manual. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.

More information

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater SUPPLY UNITS Series Series LCD control panel SAS908 control panel Supply units with the air capacity up to 3500 m 3 /h in the compact sound- and heat-insulated casing with electric heater Supply units

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX 2218 F/2TDH4P

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX 2218 F/2TDH4P Operating manual 2218 F/2TDH4P 1 SAFETY REGULATIONS AND INFORMATION Read the operating manual carefully before commencing work at the product. Pay attention to the following warnings to avoid risk to persons

More information

Centrif Duo & Centrif Duo Plus

Centrif Duo & Centrif Duo Plus Centrif Duo & Centrif Duo Plus Installation and Wiring Instructions Stock Ref. N Centrif Duo P 25 61 20D Centrif Duo T 25 62 20D Centrif Duo DP 25 63 20D Centrif Duo HTP 25 64 20D Centrif Duo Centrif Duo

More information

Drying Cabinet With Timer

Drying Cabinet With Timer Malmet (Australia) Pty Ltd Head Office & Customer Service 9-11 McKay Avenue PO Box 373 LEETON NSW 2705 Phone: (02) 6953 7677 Email: inquiries@malmet-aus.com.au ABN 95 001 717 791 Operation, Maintenance

More information

Quest Power Electric Heat EHS 31 Pro

Quest Power Electric Heat EHS 31 Pro Quest DRY Power 150 Electric Heat EHS 31 Pro Read and Save These Instructions The Power Electric Heat EHS 31 Pro portable, heavy duty electric heater features a built-in 50-amp twist lock receptacle designed

More information