WHISPER Hall. Climaveneta Technical Bulletin. Packaged reversible Rooftop unit, air cooled, high efficiency for high crowding applications

Size: px
Start display at page:

Download "WHISPER Hall. Climaveneta Technical Bulletin. Packaged reversible Rooftop unit, air cooled, high efficiency for high crowding applications"

Transcription

1 Climaveneta Technical Bulletin WHISPER_HALL_0110_0400_201203_EN r HFC R-410A kw Packaged reversible Rooftop unit, air cooled, high efficiency for high crowding applications (The photo of the unit is purely indicative and may vary depending on the model) High energy efficiency Variable flow-rate Thermodynamic effect Plug fans Enthalpic heat recovery

2 SUMMARY 1. : LEED RELEVANT PRODUCT p PRODUCT PRESENTATION 5 3. MAIN COMPONENTS 6 4. DESCRIPTION OF THE UNIT 9 5. STANDARD UNIT CONFIGURATIONS OPERATING MODES ACCESSORIES GENERAL TECHNICAL SPECIFICATIONS OPERATING LIMITS SOUND LEVELS DIMENSIONAL DRAWINGS 24 Company quality system certified to UNI EN ISO 9001 and environmental certification UNI EN ISO Waiver of liability This publication represents a preliminary document, and is the sole property of Climaveneta. Any reproduction or disclosure of such is strictly prohibited without the written authorisation of Climaveneta. This document has been prepared with maximum care and attention paid to the content shown. Nonetheless, Climaveneta waives all liability deriving from the use of such document. Read this document carefully. All work must be performed, components selected and materials used professionally and in complete accordance with the legislation in force in material in the country concerned, and considering the operating conditions and intended uses of the system, by qualified personnel. The data contained in this publication may be changed without prior notice. 2 WHISPER_HALL_0110_0400_201203_EN

3 : LEED RELEVANT PRODUCT The LEED protocol is the most known protocol of sustainability to define and measure green buildings all around the world. Based on existing and proven technology, it evaluates environmental performance from a whole building perspective over a building s life cycle, providing a definitive standard for what constitutes a green building in design, construction and operation. The LEED rating systems are designed for rating new and existing commercial, institutional and residential buildings. They are based on accepted energy and environmental principle and strike a balance between known, established practices and emerging concepts. Each rating system is organized into 7 environmental categories: Sustainable Sites, Water Efficiency, Energy and Atmosphere, Materials and Resources, Indoor Environmental Quality, Innovation in Design and Regional Bonus. units are compliant with the performance standard contained in the protocol of sustainability LEED. In detail, units contribute to the following points: prerequisite 2 in ENERGY & ATMOSPHERE topic WHISPER HAll units, upon check of the commercial office, are ASHRAE compliant. The Minimum Efficiency Requirements detailed in the table 6.8.1A/B of the American standard are guaranteed. TABLE 6.8.1A Electrically Operated Unitary Air Conditioners and Condensing Units Minimum Efficiency Requirements Equipment Type Size Category Heating Section Type Sub-Category or Rating Condition Minimum Efficiency a Test Procedure b 65,000 Btu/h and <135,000 Btu/h Electric Resistance (or None) All other Split System and Single Package Split System and Single Package 10.3 EER (before 1/1/2010) 11.2 EER (as of 1/1/2010) 11.4 IEER (as of 1/1/2010) 10.1 EER (before 1/1/2010) 11.0 EER (as of 1/1/2010) 11.2 IEER (as of 1/1/2010) 135,000 Btu/h and <240,000 Btu/h Electric Resistance (or None) All other Split System and Single Package Split System and Single Package 9.7 EER (before 1/1/2010) 11.0 EER (as of 1/1/2010) 11.2 IEER (as of 1/1/2010) 9.5 EER (before 1/1/2010) 10.8 EER (as of 1/1/2010) 11.0 IEER (as of 1/1/2010) Air Conditioners, Air Cooled 240,000 Btu/h and <760,000 Btu/h Electric Resistance (or None) All other Split System and Single Package Split System and Single Package 9.5 EER (before 1/1/2010) 10.0 EER (as of 1/1/2010) 9.7 IPLV (before 1/1/2010) 10.1 IEER (as of 1/1/2010) 9.3 EER (before 1/1/2010) 9.8 EER (as of 1/1/2010) 9.5 IPLV (before 1/1/2010) 9.9 IEER (as of 1/1/2010) ARI 340/ ,000 Btu/h Electric Resistance (or None) All other Split System and Single Package Split System and Single Package 9.2 EER (before 1/1/2010) 9.7 EER (as of 1/1/2010) 9.4 IPLV (before 1/1/2010) 9.8 IEER (as of 1/1/2010) 9.0 EER (before 1/1/2010) 9.5 EER (as of 1/1/2010) 9.2 IPLV (before 1/1/2010) 9.6 IEER (as of 1/1/2010) 3 WHISPER_HALL_0110_0400_201203_EN

4 prerequisite 3 in ENERGY & ATMOSPHERE topic units use the refrigerant R410A, which is compliant with the GWP limitations set by the protocol. In detail, this refrigerant isn t a (CFC)-based refrigerant as moreover prescribed by the most of the national legislation around the world. credit 1 in INDOOR ENVIRONMENTAL QUALITY topic units may be provided with a CO 2 probe to constantly monitor the indoor air quality and therefore set the optimum ventilation conditions. This characteristic, together with the measurement of the fresh air flow to be injected into the room (at customer care), is considered in the OUTDOOR AIR DELIVERY MONITORING credit, which weights for 1 point in the LEED protocol. credit 2 in INDOOR ENVIRONMENTAL QUALITY topic LEED protocol rewarded with 1 point the buildings with an air treatment plant designed to grant the maximum IAQ. In detail, if the air treatment units can assure an additional fresh air injection, a smart management of the recovery of the rejected heat for the air renewal and the capability to implement free cooling mode when convenient, 1 point can be gained. units can all be provided with these optional on request credit 5 in INDOOR ENVIRONMENTAL QUALITY topic units are available with high performing filters, F7 and electronic ones, that assure an advanced air filtration minimizing the building occupant exposure to potentially hazardous particulates and chemical pollutants. This credit INDOOR CHEMICAL AND POLLUTANT SOURCE CON- TROL weights for 1 point in the scoring system credit 7 in INDOOR ENVIRONMENTAL QUALITY topic This credit implies up to 1 point for the buildings characterized by a comfortable thermal environment that promotes occupant productivity and well-being. All the units, thanks to the advanced thermoregulation logics, the adoption of well-sized humidifiers and post-heating coils, grant a precise and fine regulation of the most important variables, ensuring the highest indoor air quality Other points can be gained as indirect consequence of an high efficient air conditioning system choice. In particular: credit 1 in ENERGY & ATMOSPHERE topic units, especially the CA and CA-E versions, contribute to OPTIMIZE ENERGY PERFORMANCE of the building. As known, air-conditioning and ventilation systems are responsible for approximately a third of the total energy consumption in a modern building. The proper size and design of each component involved in comfort creation determine a relevant energy saving, prize by LEED protocol with up to 19 points. The amount of points assigned to the building depend to the percentage of energy saving calculated compared with the baseline building performance rating: 1 point for an improvement in energy performance of 12% and 19 points for energy improvement higher than 48%. The baseline building performance are defined according to Appendix G of ASHRAE standard credit 1 in INNOVATION IN DESIGN topic 5 more points can be gained by design teams and projects that achieve exceptional performance above the requirements set by the LEED Green Building Rating System and/or adopt innovative solution not specifically addressed by the LEED Green Building Rating System. All units use the thermodynamic effect of the exhaust air on the external coil, to recover the heat rejected for the air renewal and improve the working conditions of the cooling circuit. Moreover the units are all capable to operate with variable air flow according to the thermal load and are suitable to be provided with latest generation filters: these advanced design techniques could be classified as innovative and therefore contribute to achieve some points in this topic. Climaveneta is a Green Building Council Italy and actively supports the diffusion of LEED practice all around the world There are already several buildings LEED certified also tank to Climaveneta HVAC systems. For more information, browse the project reference list at GLOSSARY GWP: Global Warming Potential Index that express the contribution given by a greenhouse effect gas emission into the atmosphere. All the molecules have a potential defined in relation to the CO 2 molecule, which has a potential of 1 and acts as a reference. CFC: ChloroFluoroCarbon LCGWP: Life Cycle Global Warming Potential Index that define a threshold for the global warming potential estimated for the product life-cycle. It is a function of the following variables: - refrigerant GWP - refrigerant leakage rate and end-of-life refrigerant loss - estimated equipment life - refrigerant charge IAQ: Indoor air quality 4 WHISPER_HALL_0110_0400_201203_EN

5 2. PRODUCT PRESENTATION The rooftop units are high efficiency packaged air-to-air reverse-cycle units, for complete air temperature and humidity control. Filtration, ventilation and air renewal are guaranteed by a packaged solution that perfectly suits high volume application with high crowding and high latent load, like cinemas and theatres. The cooling section comes as standard with two refrigerant circuits, scroll compressors, R410A refrigerant and heat exchange coils with intertwined circuits; the air handling section uses plug fans as standard for the supply and return air, thermodymanic effect of the exhaust air on the external coil. Efficiency, reliability, versatility and simple maintenance are the result of precise technological decisions, meaning the WHISPER Hall unit can ensure maximum design and operating freedom. 2.4 Simplified installation and maintenance The rooftop units simplify and reduce the costs of maintenance and work on site, through: Compact dimensions for simplified transport, handling and positioning on site, making these operations make more economical compared to traditional units. Sturdy and perfectly insulated structure that guarantees resistance to the elements and mechanical stress Easy access to the inside sections and the components that require periodical cleaning, for fast and economical routine maintenance. PLUG and PLAY construction that ensures, once the unit has been positioned, simpler and faster electrical and air connections. Automatic calibration of air flow-rates, with consequent savings in technical service and greater comfort 2.2 Energy efficiency The units stand out in the Climaveneta range of packaged units for the choice of components and solutions aimed at energy efficiency. The AIR 3000 SE controller optimises unit operation in all conditions, through intelligent management of the devices available. High efficiency plug fans to simplify installation and maintenance operations and reduce power consumption required for ventilation; Enthalpic wheel heat recovery, making a significant contribution to overall unit performance; Heat exchange coils with intertwined circuits, to achieve greater heat transfer efficiency during operation at part load; Thermodynamic heat transfer between the exhaust air and the outdoor coil, allowing the unit to operate with more advantageous condensing temperatures Freecooling to reduce the use of the refrigerant circuit by exploiting favourable outside air conditions. 2.3 Complete range The Whisper Hall range consists of eight sizes, available in a single configuration to satisfy all system requirements, being supplied with a complete set of standard components and a vast selection of accessories. This units are specifically designed for high crowding applications where a high air renewal is required (maximum 75%); The CO 2 air quality probe, that optimizes the opening of the dampers according to the real ambient needs, is supplied as standard to reduce the unit s consumption. The units use plug fans on both the air supply and return. Based on innovative control logic developed by Climaveneta, these ensure ventilation remains constant over time while reducing unit power consumption by 30% The availability of different filtering options (mechanical or electronic) ensures the best response to the specific requirements of each installation: maximum air quality can be obtained with G3 filters combined with F7 (mechanical bag filters) or H10 (electronic filters), as required. Reversing of the refrigerant circuit and freecooling/freeheating operation allow continuous service within the wide range of operating limits, achieved through careful sizing of the components and specific design choices. 5 WHISPER_HALL_0110_0400_201203_EN

6 3. MAIN COMPONENTS 3.1 Plug fans Ventilation on all Whisper Hall units is managed using plug fans with backward inclined blades. These differ from traditional centrifugal fans due to absence of the scroll and direct coupling to the motor, thus eliminating energy loss from the belt and pulley transmission. Depending on the air flow-rate, EC brushless or asynchronous motors with inverter control are used, allowing electronic speed control via a 0-10 V signal. This type of technology ensures clear advantages, with installation being simplified based on the parameters set by the user, without needing any flow-rate adjustment during calibration. In addition, fan speed adapts to the characteristics of the system even when the unit is operating, for example compensating for any variations in flow-rate due to progressive fouling of the filters. The low power consumption of these types of fans can be further reduced by applying the exclusive control logic developed by Climaveneta. All this means high operating efficiency even for the part involving the fans, traditionally a critical area in terms of running costs. 3.2 Variable flow-rate On rooftop units, that directly serve the air-conditioned environment and represent the main source of ventilation, the supply and return fans work continuously at a fixed flow-rate (constant speed), in all operating conditions, even during freecooling and at part loads, which together account for the majority of operating hours. Consequently, power consumption from fan operation on rooftop units represents over 50% of total annual unit power consumption, which is why Climaveneta decided to develop a system for controlling fans that could reduce fan power consumption. The most effective way to reduce power consumption is to decrease fan speed, and consequently flow-rate, whenever system operating conditions allow. 6 WHISPER_HALL_0110_0400_201203_EN

7 The advanced logic featured on the AIR 3000 SE controller and the use of plug fans with electronic speed control have allowed the variable flow-rate function to be developed. This involves changing the supply and return air flow-rate based on effective demand from the system, considering the activation percentage of each device - compressors, heaters or burners, freecooling or freeheating; for example, progressive shutdown of the compressors will bring a reduction in air flow-rate, defined within the limits set by the user. This means flow-rates are managed based on the actual conditions in the air-conditioned space, while still observing any limits defined on the components and the type of system. In addition to benefits in terms of comfort, there are also economic advantages, as reducing fan speed cuts total unit power consumption by 30% compared to the traditional fixed flow-rate solution. 3.3 Rotary enthalpy recovery This is the most efficient recovery system, with efficiency ranging from 60% to 90% depending on operating conditions, thanks to the exchange surface, which is very high compared to volume. The main component is the enthalpic wheel made with alternating flat and corrugated aluminium sheets. As a series of paths are created, along which renewal and discharge air flows run in opposite directions, it recovers latent heat as well as sensible heat. This makes it possible to reduce the inflow of humidity during summer operation and to reduce or even eliminate any winter humidification device, considerably increasing overall unit efficiency. The rotor is powered by a constant-speed electric motor with a very low power input. Operating principle In the rotary heat recovery, heat transfer is realized thanks to heat store in the wheel. While the wheel is slowly turning, the exhaust air flows through one half of the wheel and transfers heat at the rotor that stores it. The fresh air, which flows through the other half, absorbs the stored heat. As the wheel continues to rotate, the parts that absorb and give up the heat swap over continuously. Summer operating Winter operating EXHAU XHAU EXHAU XHAU EXHAU EXHAU FRESH AIR FRESH AIR 7 WHISPER_HALL_0110_0400_201203_EN

8 3.4 Thermodynamic effect Thermodynamic heat transfer allows efficient use of the remaining energy contained in the exhaust air, by forcing this through the outside section of the refrigerant circuit. This consequently increases unit performance, allowing operation at a condensing temperature that s more advantageous than the outside temperature, meaning lower power consumption and higher overall efficiency. 3.5 Intertwined circuits All units in the Whisper Hall range feature two refrigerant circuits and heat exchange coils with intertwined circuits: both circuits run through both the indoor and outdoor coils, with pipes that criss-cross the entire surface area. This constructional solution allows the unit to work at part load over a heat transfer surface - represented by the area of the fins - that is larger than the solution with two independent coils for each circuit. This implies greater overall unit efficiency at part load and is available on the indoor coil for all models, and on the outdoor coil for models 0102 to AIR 3000 SE advanced controller All units are fitted with the AIR 3000 SE controller, especially developed by Climaveneta for rooftop units, featuring a liquid crystal display (LCD). This keypad accesses a user interface with seven European languages available; users can choose between Italian, English, French, German, Spanish, Swedish and Russian. This allows an interface that s specific for the country where the unit is installed, or alternatively, by setting English, completely independent for all other regions. Temperature control is performed using algorithms that control available devices (compressors, hot gas reheating coil, heating devices) based on the unit configuration; control is applied using the return air temperature probe reading, based on proportional or proportional + integral logic. Interfacing to commercially-available BMS systems is provided thanks to compatibility with BACnet, BACnet OverIP, ModBus and LonWorks protocols. The built-in clock provides a daily scheduler function, organised into time bands so as to optimise unit operation, minimising system energy consumption. In fact, several time bands (up to 10) of different types (4) can be activated throughout the day, with each band being assigned: temperature set point for cooling and heating humidity set point unit operating modes: control on, off, purging, start-up. constant pressure/flow: as pressure drop varies, the fans change speed so as to maintain pressure/flow-rate at the design value for the system, regardless of filter clogging and the actual static pressure of the ducting; variable flow-rate: as the percentage of unit device activation changes, the flow-rate varies within limits set by the user. Other available functions include: room humidity control in cooling and heating mode automatic temperature- and enthalpy-based freecooling management self-adaptive defrost management using algorithms that reduce defrost duration or prevent unnecessary or wasteful cycles demand limit on compressors to reduce mains power consumption set point compensation based on outside temperature, in both cooling and heating operation. Also available are display and acquisition of the last 200 alarm events (user level), as well as recording of operating variables in the 10 minutes prior to each alarm event (Black Box) with display via PC. Compatibility with remote keypad (management of up to 10 units). The fan section can be managed in the following modes: ON/OFF: the fans are on at maximum rotation speed or off, depending on whether or not the heating-cooling devices are operating; constant speed: the supply and return fans maintain a constant rotation speed; 8 WHISPER_HALL_0110_0400_201203_EN

9 4. DESCRIPTION OF THE UNIT Packaged autonomous Rooftop unit, reversible air cooled, for air temperature-humidity control, filtering and air change in large spaces with high crowding and volume. Operates in both winter and summer seasons, two refrigerant circuits, scroll compressors with R410A refrigerant, finned coil outdoor heat exchangers with thermodynamic effect of the exhaust air, axial-flow fans. Air handling section with plug fans on supply and return, rotary enthalpic heat recovery, finned coil indoor heat exchanger and motorised outside air, mixing and exhaust dampers. Air flow-rate management by constant pressure/flow-rate or variable flow-rate based on heating or cooling demand, CO 2 probe for the air quality control. Structure Outdoor structure with base made from hot galvanised steel sections, painted with epoxy powder coat, and Peraluman aluminium alloy panelling. Air handling section (indoor) completely separated from the refrigerant circuit control devices by double chamber, made from aluminium alloy sections and double wall sandwich panelling with 42 mm thick polyurethane foam insulation in between, inner surface made from hot galvanised sheet metal and outer surface from Peraluman aluminium alloy. The panels can be removed for complete access to the inside components. Compressors Hermetic rotary scroll compressors, R410A refrigerant, housed in a separate compartment; each compressor is fitted with crankcase heater and a two-pole electric motor with direct starting, internally protected against excess temperature. Indoor heat exchanger Direct expansion air handling coil for heat exchange with the refrigerant gas, made from a coil of mechanically expanded copper tubes and corrugated aluminium fins. Aluminium basin for collecting condensate, with sloping bottom and complete with drain attachment. Both refrigerant circuits use the entire heat exchange surface available (intertwined circuits), so as to achieve high energy efficiency with the unit operating at part load. The speed of the air through the coil is kept below the limit value of 2.7 m/s, even at full flow, to avoid entraining condensate, including in the most extreme temperature-humidity conditions. Outdoor heat exchanger Direct expansion outdoor coil for heat exchange between the refrigerant gas and the outside air, made from a coil of mechanically expanded copper tubes and corrugated aluminium. On sizes from 0102 to 0404, both refrigerant circuits use the entire heat exchange surface available (intertwined circuits), so as to achieve high energy efficiency with the unit operating at part load. Refrigerant circuit The unit has two refrigerant circuits to ensure reliability, easy maintenance and repairs in the event of faults. Each circuit is also complete with the following: R410A refrigerant charge filter-drier liquid flow indicator thermostatic expansion valve with external equaliser liquid separator charge and pressure control valves high and low pressure safety valves non-return valve four-way valve for reversing the cycle. Indoor fans The supply and return fans are plug fans, with statically and dynamically balanced impellers according to DIN ISO 1940, quality grade G2.5 and G6.3. The motors are standard size with IP55 protection, class F insulation, directly coupled EC brushless motors; the fans are fitted with differential pressure transducers. Outdoor fans Wing shaped axial fans in die-cast aluminium, with external rotor. The electric motor is fitted with built-in thermal protector and self-supporting protective mesh on the outside. Motor index of protection IP55, insulation class F.. Filtering section Filtering section made by G3 synthetic fibres plated filter for air treatment section, G1 metallic mesh filter and G3 synthetic fibres plated filter for fresh air section, G3 synthetic fibres plated filter for return air section. Placed on steel guides easily accessible for ordinary maintenance and replacement. Heat recovery Energy recovery system on the exhaust air, made up of a high efficiency enthalpy wheel consisting of alternating flat and corrugated aluminium sheets, with hygroscopic treatment, so as to create a series of passageways in the opposing directions to the flows of fresh and exhaust air. The wheel is driven by an electric motor at constant speed with very low power consumption. Both sensible and latent energy is recovered: this limits the introduction of moisture into the room during summer and increases humidity in winter. CO 2 probe for the air quality CO 2 probe for the air quality management, typically related to the crowding in the ambient. The controller processes a signal that allows to manage the fresh air volume, thus granting the respect to local rules and the thermohygrometric comfort for the occupants. Rainproof hood Metal rain grill fitted on the external air damper for all models to avoid suction of water inside the chamber, and anti-intrusion net on the expulsion damper. Power and control electrical panel Power and control electrical panel built in compliance with EN and IEC204-1, complete with: control circuit transformer main door lock disconnect switch power section with busbars fuses and contactors for compressors and fans spring-loaded terminals on the control circuits (cage clamp) microprocessor electronic controller with supply temperature control. Protected by a removable Peraluman panel and two hinged doors with gaskets. Unit power supply voltage: 400V~ ±10% - 50Hz - 3N. 9 WHISPER_HALL_0110_0400_201203_EN

10 AIR 3000 SE controller The AIR3000 SE controller stands out for its advanced functions and proprietary control strategies. The keypad features function controls and a complete LCD display for viewing data and activating the unit, via a multilevel menu, with settable display language. It can be used to set the unit start-up and indoor air purging stages, as well as to set unit the operating mode (manual heating or cooling, automatic changeover). Temperature control is based on proportional or proportional + integral logic using the return air temperature probe reading; the set point can also be adjusted based on the outside temperature, in both cooling and heating mode. Defrosts use proprietary self-adaptive logic involving monitoring of multiple operating and climate parameters. This reduces the number and duration of defrosts, consequently increasing overall energy efficiency. Supervision is available with different options, using proprietary devices or by integration into third party systems using ModBus, BACnet, BACnet-over-IP and Echelon LonWorks protocols. Compatibility with remote keypad (management of up to 10 units). The timer can be used to create an operating profile with up to 4 typical days and 10 different time bands. Certification Unit compliant with the following directives and amendments: Machinery directive 2006/42/EC. EMC 89/336/EEC /108/EC. Low voltage directive 2006/95/EC. Pressure equipment directive 97/23/EC. Form A1. TÜV Italia WHISPER_HALL_0110_0400_201203_EN

11 5.1 FCC Freecooling with plug fans on supply and return The units are available in one single configuration with three motorised dampers managed by the AIR 3000 SE controller on the unit, and allows automatic management of air supply, return, change, exhaust and recirculation. The unit works completely autonomously, without the need to extract air from the air-conditioned space using other devices: the supply air plug fan ensures the design air flow-rate, while the return air plug fan ensures recirculation and exhaust from the air-conditioned space. The control AIR 3000 SE controller also manages the freecooling function, as well as washing and start-up. 6. OPERATING MODES 6.1 Normal operation with mixing During normal operation the unit creates a mixture of return air from inside the space and outside air, in a fixed percentage set by the user, or managed automatically by the CO 2. The exhaust and outside air dampers are opened to a proportion such as to maintain pressure balance, based on the user settings, while recirculation damper management is complementary. 6.2 Freecooling / Freeheating operation This function is enabled when the temperature or enthalpy (optional) conditions of the outside air allow. The outside air and exhaust dampers are opened completely and the mixing damper is closed during 100% freecooling, the recovery wheel is stopped. The device.s are progressively deactivated until they shut down completely; the percentage of freecooling is progressively reduced and the mixing damper opens as a consequence when the outside temperature falls. 11 WHISPER_HALL_0110_0400_201203_EN

12 6.3 Washing This optional function cleans the space with fresh outside air, without any additional process, and can be used after an extended period of closing or whenever the air inside the space needs to be changed quickly. During this procedure the compressors are off, the mixing damper is closed, while the exhaust and outside air dampers are fully open. 6.4 Start-up This optional function quickly brings the space to the desired temperature, when unoccupied, by completely recirculating the air, and can be used after the washing function. During this procedure the compressors are on, the outside air and exhaust dampers are closed, while the mixing damper is fully open. 12 WHISPER_HALL_0110_0400_201203_EN

13 7. ACCESSORIES CODE ACCESSORY NAME DESCRIPTION ADVANTAGES 411 Electrical Panel with forced ventilation 3301 Power factor correction 3412 Automatic circuit breakers Condensators on the compressors' power inlet line. Over-current switch on the major electrical loads Echelon connectivity Interface module for Echelon systems 4184 BACnet connectivity Interface module for BACnet protocols 1401 HP AND LP GAUGES High and low pressure gauges. 881 Cu/Cu condensing coils Condensing coils with epoxy-coated fins Condensing coils with Fin Guard Silver treatment 971 Cu/Cu internal coil Internal coil with Fin Guard Silver treatment Internal coil with pre-painted fins 1300 Water heating coil 1310 Electrical heating coil Pressostatic condensing control for low ambient Variable step speed condensing control device Continuous variable speed condensing control 1337 Hot gas Post heating Air-refrigerant heat exchanger with copper fins and tubes. Painted air-refrigerant heat exchanger. Air-refrigerant heat exchanger with epoxidic treatment on coils and fins. Internal air treatment coil with copper fins and tubes. Internal air treatment coil with epoxidic treatment on coils and fins. Internal air treatment coil with prepainted fins Water heating coil installed after the internal treatment coil Electrical heater installed after the internal treatment coil Step management of the axial fans on the base of the condensing pressure Electrical transformer to manage the air flow at 3 fixed speed values according to the condensing temperature. Continuous fans speed control on the base of the condensing pressure, cutting phase device Condensing finned coil, installed dowstream the treatment coil, fed by hot gas coming from the compressor's supply. For a correct functioning, this option is supplied with a humidity probe. The unit's average cos(phi) increases to a value (average) of 0,92. It protects compressors and/or fans from possible current peaks. Allows integration with BMS operating with LonWorks procotls Allows integration with BMS operating with BACnet protocol Allows immediate reading of the pressure values on both low and high pressure circuits. Recommended for applications in corrosive atmospheres Recommended for applications in medium level pollution atmospheres. Recommended for marine exposure conditions, with an high level of pollution or other aggressive atmospheres. Recommended for applications in corrosive atmospheres Recommended for marine exposure conditions, with an high level of pollution or other aggressive atmospheres. Recommended for applications in medium level pollution atmospheres. The coil is a heating source which can be used as integration or sobstitution in heat pump working. The electrical heating coil is a heating source which can be used as integration in heat pump working. When the unit is working at low external air temperatures, the device stops one or more fans in sequence in order to maintain control over condensing pressure When the unit is working at low external air temperatures, the uniform reduction of airflow over the entire surface of the coil offers accurate control of condensing pressure and decreases the overall noise level of the unit. When the unit is working at low external air temperatures, the uniform reduction of airflow over the entire surface of the coil offers accurate control of condensing pressure. Enthalpic control to bring the ambient humidity back to wellbeing values. Initial de-humidification phase made by the evaporating coil, that reduces humidity content in the air; final phase with post heating made by hot gas coil to correct supply air temperature 13 WHISPER_HALL_0110_0400_201203_EN

14 CODE ACCESSORY NAME DESCRIPTION ADVANTAGES way valve 2101 Rubber anti vibration device 2062 Right return air direction 2065 Left return air direction 2521 High efficiency bag filters, F Electronic filters 4121 Forced shut down 4142 External forcing 4-20 ma 4171 Remote forcing for air estraction 4172 Remote room washing 4173 Washing and running up Modulating mixing valve installed dowstream the water heatign coil, supplied mounted and with modulating drive. Return air on the right side, as regards of the air flow direction, to be specified in the order Return air on the left side, as regards of the air flow direction to be specified in the order Available in addition to standard filters, they are made from F7 efficiency fibreglass paper and are Class 1 fire resistant. The large inspection panels and steel guides make them easy to remove for cleaning or replacement. Fitted at the coil inlet and used instead of mechanical filtration F7. The electrostatic precipitation process, lying at the heart of the operating principle, comprises three main stages: electrically charging the airborne particles; capturing the particles; removing the captured particles. The particles are electrified by a discharge ionising device. Digital inlet to switch off the unit from remote Remote forcing with 4-20 ma signal to manage the dampers for air renewal Digital input that manage the closing of the recirculation damper, the opening of the outlet and inlet dampers, the switching off of the compressors and the start of he supply and return fans Digital input for the complete renewal of air in the empty room. Estraction and expulsion of the ambient air, introduction of renewal external air with switched off compressors Function to be activated when the room is empty, first washing of the air in the room and then start-up in total air recirculation. Mounted on the treatment coil inlet, they ensure that the air effectively introduced into the room is filtered. Used in high-efficiency applications (yields of 99%) to trap dust particles as small as one micrometre in diameter. Featuring very low pressure drops, they also save ventilating power. Electrostatic filters are designed for long service life and very low maintenance requirements, apart from routine cleaning which is automatically indicated by the filters. They also remove harmful pathogenic agents. High efficiency combined with a long service life allows the initial cost of the investment to be amortised by the extremely low management and running costs. Renewal of ambient air when the room has not been used for a long time or whenever all the ambient air requires rapid changing 14 WHISPER_HALL_0110_0400_201203_EN

15 CODE ACCESSORY NAME DESCRIPTION ADVANTAGES 4132 Enthalpic Free cooling Function manged by temperature and humidity probes, installed in a position allowing them to check and compare the energy status of both the ambient and the external air. The control manages the opening/closing of the dampers in order to exploit more favourable external conditions. During Free cooling functioning, the resources are progressively disconnected, till complete switch off, keeping the requried termohygrometric ambient condition, thanks to the external favourable conditions Ambient humidity probe 4271 Ambient air probe 4272 Return air probe 4300 Steam humidifier 1852 Filters differential pressure switch 4240 Return fan uprated motor 4250 Supply fan uprated motor Probe to measure relative humidity percentage in the ambient, intalled on the return Return air temperature probe supplied loose for ambient installation Return air temperature probe supplied loose for return duct installation Humidification takes place directly inside the unit using a steam diffuser immersed in the flow of treated air. The steam is generated inside an immersed electrode humidifier. Differential air presure switch to detect filters' obstruction, with warning Increment of the motor electrical power of the return fans Increment of the motor electrical power of the supply fans Adjustment of relative humidity in winter mode Increment of the static available pressure at the return fans intlet Increment of the static available pressure at the supply fans outlet 15 WHISPER_HALL_0110_0400_201203_EN

16 8. GENERAL TECHNICAL SPECIFICATIONS SIZE Cooling Cooling capacity kw 45,9 55,7 63,7 72,0 98,3 115,4 127,7 146,3 Cooling capacity recovery kw 11,1 13,1 15,4 16,7 25,7 28,8 32,6 34,1 Sensible capacity kw 25,1 31,1 36,8 41,6 55,7 65,1 73,7 83,2 Compressor power input kw 7,6 10,9 12,4 15,0 14,9 20,4 24,1 29,0 Heating Heating capacity kw 53,1 65,4 75,5 84,4 115,4 137,0 153,8 171,1 Heating capacity recovery kw 26,4 31,3 36,8 40,4 60,8 68,4 77,9 81,7 Compressor power input kw 7,1 8,8 9,7 11,7 12,4 16,8 19,4 21,5 Supply fan Type Plug fan (EC) Quantity no Supply air flow-rate m 3 /h Available static pressure Pa Unit power consumption kw 0,5 0,65 0,9 1,17 1,54 2,01 2,82 3,21 Return/exhaust fans Type Plug fan (EC) Quantity no Return air flow-rate m 3 /h Available static pressure Pa Unit power consumption kw 0,40 0,47 0,7 0,9 0,79 0,98 1,52 1,48 Outdoor fans Type Axial-flow Quantity no Outside air flow-rate m 3 /h Unit power consumption kw 0,48 0,48 0,48 0,48 2,00 2,00 2,00 2,00 Compressors Type Scroll Number of compressors no Number of circuits no Capacity steps no Charge Refrigerant kg 11,6 12,5 13,2 18,4 19,1 20,3 28,1 29,0 Oil kg 3,9 6,5 6,5 6,5 6,5 8,0 13,2 13,0 Standard unit dimensions Length mm Width mm Height mm Std. unit weight in operation kg Total sound power (1) Supply db(a) Return db(a) Outside db(a) Reference conditions Cooling: Outside 32 C 50% RH - Inside 26 C 50% U.R. - Mixture 75% Heating: Outside -5 C 85% RH - Inside 20 C 50% U.R. - Mixture 75% (1) Sound power Sound power values are taken from the supplier s technical documents and refer to individual fans with ducted outlet and open intake 16 WHISPER_HALL_0110_0400_201203_EN

17 SUPPLY FAN MOTOR SPECIFICATIONS Size Air flow-rate Standard m 3 /h Pa (1) rpm kw cons. kw inst ,9 2, ,1 2, ,4 2, ,4 2, ,9 3, ,1 3, ,3 3, ,3 3,6 (1) Pa: Maximum available static pressure, unit in basic configuration RETURN FAN MOTOR SPECIFICATIONS Size Air flow-rate Standard m 3 /h Pa (1) rpm kw cons. kw inst ,9 2, ,1 2, ,4 2, ,4 2, ,87 3, ,11 3, ,28 3, ,3 3,6 (1) Pa: Maximum available static pressure, unit in basic configuration 17 WHISPER_HALL_0110_0400_201203_EN

18 ELECTRICAL DATA Maximum values Size no. F.L.I. [kw] F.L.A. [A] Compressors F.L.I. [kw] F.L.A. [A] L.R.A. [A] no. Each supply fan (1) F.L.I. [kw] F.L.A. [A] Each return fan (1) Outdoor fans Total (1) ,67 9,70 5,67 9,70 64,00 2 2,50 4,00 2 2,50 4,00 2 0,48 0,93 22,30 37,26 91, ,87 13,75 7,87 13,75 101,00 2 2,50 4,00 2 2,50 4,00 2 0,48 0,93 26,70 45,36 132, ,69 14,78 8,69 14,78 92,00 2 2,50 4,00 2 2,50 4,00 2 0,48 0,93 28,34 47,42 124, ,23 18,05 10,53 18,36 142,00 2 2,50 4,00 2 2,50 4,00 2 0,48 0,93 31,72 54,27 177, ,40 19,45 11,40 19,45 130,00 2 3,60 5,70 2 3,60 5,70 2 2,00 4,00 41,20 69,70 180, ,71 24,15 14,71 24,15 158,00 2 3,60 5,70 2 3,60 5,70 2 2,00 4,00 47,82 79,10 212, ,57 29,48 16,57 29,48 160,00 2 3,60 5,70 2 3,60 5,70 2 2,00 4,00 51,54 89,76 220, ,57 29,48 22,76 38,29 215,00 2 3,60 5,70 2 3,60 5,70 2 2,00 4,00 57,73 98,57 275,28 no. F.L.I. [kw] F.L.A. [A] no. F.L.I. [kw] F.L.A. [A] F.L.I. [kw] F.L.A. [A] S.A. [A] (1) Standard motors F.L.I. Power consumption at max. conditions allowed. F.L.A. Current draw at max. conditions allowed. L.R.A. Peak current of individual compressor. S.A. Peak current of unit with standard motors. Power supply: - 400/3/50 WITHOUT NEUTRAL - Allowable variation in voltage 10% - Maximum unbalance between phase voltages 3% 18 WHISPER_HALL_0110_0400_201203_EN

19 Two-row hot water coil performance (water C) Model Air flow-rate A.R Water Air C kwt m 3 /h kpa Pa (1) 10 50,1 2,21 27, ,1 2,03 23, ,0 1,85 19, ,9 2,56 34, ,1 2,35 30, ,4 2,14 25, ,6 2,94 45, ,1 2,70 38, ,6 2,46 32, ,2 3,19 52, ,3 2,93 44, ,3 2,66 37, ,0 5,03 23, ,0 4,61 20, ,2 4,20 17, ,0 5,55 28, ,0 5,09 24, ,0 4,64 20, ,0 6,19 34, ,0 5,68 29, ,0 5,17 25, ,0 6,45 37, ,0 5,92 31, ,0 5,39 27,0 (1) For correct calculation of the available static pressure, subtract this value from the data for the basic unit. kwt = Heating capacity m 3 /h = Water coil flow-rate Pa = Air coil pressure drop kpa = Water coil pressure drop Three-row hot water coil performance (water C) Model Air flow-rate A.R Water Air C kwt m 3 /h kpa Pa (1) 10 66,4 2,93 21, ,0 2,70 18, ,7 2,46 15, ,5 3,42 28, ,2 3,15 24, ,9 2,87 20, ,1 3,98 37, ,8 3,66 32, ,5 3,33 27, ,3 4,35 43, ,3 3,99 37, ,3 3,63 31, ,0 6,68 20, ,0 6,15 18, ,0 5,60 15, ,0 7,43 25, ,0 6,83 21, ,0 6,23 18, ,0 8,37 31, ,0 7,69 26, ,0 7,01 22, ,0 8,74 33, ,0 8,04 29, ,0 7,32 24,6 (1) For correct calculation of the available static pressure, subtract this value from the data for the basic unit. kwt = Heating capacity m 3 /h = Water coil flow-rate Pa = Air coil pressure drop kpa = Water coil pressure drop 19 WHISPER_HALL_0110_0400_201203_EN

20 ELECTRIC COIL (optional) Unit/electric coil combinations UNIT SIZE Heating capacity Steps ELECTRIC COIL SIZE [kw] [no] 7 7,2 1 X X X X 12 12,0 2 X X X X X X X 18 18,0 2 X X X X X X X X 27 27,0 2 X X X X 36 36,0 2 X 45 45,0 2 Three-phase power supply with star connection, no neutral STEAM HUMIDIFIER (optional) Unit/humidifier combinations UNIT SIZE Power consumption Steam production HUMIDIFIER SIZE [kw] [kg/h] UM 03 2,3 3 X X UM 05 3,8 5 X X X X X X X UM X X X X X X X UM 10 7,5 10 X X X X X X X X UM 15 11,2 15 X X X X UM 25 18,8 25 X X X X UM 35 26,3 35 X UM 45 33,8 45 X 20 WHISPER_HALL_0110_0400_201203_EN

21 9. OPERATING LIMITS SIZES OPERATING LIMITS IN COOLING MODE To = Air temperature [DB] at the OUTDOOR heat exchanger inlet Ta = Air temperature [WB] at the INDOOR heat exchanger inlet Ta [ C] To [ C] OPERATING LIMITS IN HEATING MODE To = Air temperature [WB] at the OUTDOOR heat exchanger inlet Ta = Air temperature [DB] at the INDOOR heat exchanger inlet Ta [ C] To [ C] OPERATING LIMITS CALCULATED IN THE FOLLOWING CONDITIONS: - Standard air flow-rate - Correct installation and use of the unit - Unit in steady operating conditions 21 WHISPER_HALL_0110_0400_201203_EN

22 9. OPERATING LIMITS SIZES OPERATING LIMITS IN COOLING MODE To = Air temperature [DB] at the OUTDOOR heat exchanger inlet Ta = Air temperature [WB] at the INDOOR heat exchanger inlet Ta [ C] To [ C] OPERATING LIMITS IN HEATING MODE To = Air temperature [WB] at the OUTDOOR heat exchanger inlet Ta = Air temperature [DB] at the INDOOR heat exchanger inlet Ta [ C] To [ C] OPERATING LIMITS CALCULATED IN THE FOLLOWING CONDITIONS: - Standard air flow-rate - Correct installation and use of the unit - Unit in steady operating conditions 22 WHISPER_HALL_0110_0400_201203_EN

23 10. SOUND LEVELS TOTAL UNIT SOUND POWER Air Sound Octave band [Hz] at 10 m Size flow-rate power m 3 /h db(a) (1) Sound power level [db] RETURN FAN SOUND POWER Air Sound Octave band [Hz] at 10 m Size flow-rate power m 3 /h db(a) (1) Sound power level [db] SUPPLY FAN SOUND POWER Size Air flow-rate m 3 /h Sound power db(a) (1) Octave band [Hz] at 10 m Sound power level [db] Reference conditions Cooling: Outside 35 C 50% RH - Inside 26 C 52% RH - Mixture 30% (1) Sound power: based on measurements performed in accordance with ISO3744. The fan sound power level spectra are supplied by the manufacturer. 23 WHISPER_HALL_0110_0400_201203_EN

24 11. DIMENSIONAL DRAWINGS Single external coil unit H B A Dimensions and weight Model A B H weight [mm] [mm] [mm] [kg] Dimensions and weight refer to the unit in the standard configuration. Width A refers to the unit without brackets WHISPER_HALL_0110_0400_201203_EN

25 Climaveneta S.p.A. Via Sarson 57/c Bassano del Grappa (VI) Italy Tel Fax Climaveneta France 3, Village d Entreprises ZA de la Couronne des Prés Avenue de la Mauldre Epone France Tel +33 (0) Fax +33 (0) info@climaveneta.fr Climaveneta Deutschland Rhenus Platz, Holzwickede Germany Tel Fax info@climaveneta.de Climaveneta Espana - Top Clima Londres 67, Barcelona Spain Tel Fax topclima@topclima.com Climaveneta Chat Union Refrig. Equipment Co Ltd 88 Bai Yun Rd, Pudong Xinghuo New dev. zone Shanghai China Tel Fax Climaveneta Polska Sp. z o.o. Ul. Sienkiewicza 13A Legionowo Poland Tel Fax info@climaveneta.pl Climaveneta India Climate Technologies (P) LTD #3487, 14th Main, HAL 2nd stage, Indiranagar, Bangalore India Tel Fax sales@climaveneta.in Climaveneta UK LTD Highlands Road, Shirley Solihull West Midlands B90 4NL Tel: +44 (0) Fax: +44 (0) Freephone: response@climaveneta.co.uk

WSM-T. Climaveneta Technical Bulletin. Cooling only Air cooled Rooftop unit, fully Configurable and high Efficiency kw

WSM-T. Climaveneta Technical Bulletin. Cooling only Air cooled Rooftop unit, fully Configurable and high Efficiency kw Climaveneta Technical Bulletin WSM_T_0162_1204_201309_EN WSM-T r HFC R-410A 0162-1204 49-459 kw Cooling only Air cooled Rooftop unit, fully Configurable and high Efficiency (The photo of the unit is purely

More information

WSM. Climaveneta Technical Bulletin. Reversible Air cooled Rooftop unit, fully Configurable and high Efficiency kw

WSM. Climaveneta Technical Bulletin. Reversible Air cooled Rooftop unit, fully Configurable and high Efficiency kw Climaveneta Technical Bulletin WSM_0162_1204_201309_EN WSM r HFC R-410A 0162-1204 49-459 kw Reversible Air cooled Rooftop unit, fully Configurable and high Efficiency (The photo of the unit is purely indicative

More information

BRAT MC. Climaveneta Technical Bulletin BRAT_MC_0011_0121_201311_EN Condensing units 5,63 35,8 kw

BRAT MC. Climaveneta Technical Bulletin BRAT_MC_0011_0121_201311_EN Condensing units 5,63 35,8 kw Climaveneta Technical Bulletin BRAT_MC 3_EN Condensing units 5,63 35,8 kw (The photo the unit is indicative and may change depending on the model) Flexibility Adaptability SL supersilenced version available

More information

AWR HT - AW HT PRELIMINARY. Climaveneta Technical Bulletin AW(R)_HT_0122_0302_201103_EN_p

AWR HT - AW HT PRELIMINARY. Climaveneta Technical Bulletin AW(R)_HT_0122_0302_201103_EN_p Climaveneta Technical Bulletin AWR HT - AW HT 0122-0302 High temperature heat pump (reverse-cycle) with hot water 34 118 kw production up to 65 C for central heating and domestic hot water ((The photo

More information

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h COMFORT ROOFTOP UNITS AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM 10000 TO 45000 m3/h climaveneta.com COMFORT ROOFTOP UNITS ENGINEERED FOR MAXIMUM EFFICIENCY AND VERSATILITY

More information

NECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw

NECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw Climaveneta Technical Bulletin NECS_N_0202T_0612T_201007_GB r HFC R-410A 0202T - 0612T 53-159 kw Reversible unit, air source for outdoor installation (The photo of the unit is indicative and may change

More information

NECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw

NECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw Climaveneta Technical Bulletin NECS_N_0202T_0612T_201211_EN r HFC R-410A 0202T - 0612T 53-159 kw Reversible unit, air source for outdoor installation (The photo of the unit is indicative and may change

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...

More information

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and

More information

NX-N. Climaveneta Technical Bulletin NX_N_0604T_1204T_201211_EN

NX-N. Climaveneta Technical Bulletin NX_N_0604T_1204T_201211_EN Climaveneta Technical Bulletin _201211_EN 060T - 120T 160 319 kw Reversible unit, air source for outdoor installation (unit with shell and tubes exchanger) (The photo of the unit is purely indicative and

More information

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning : Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: 7 102 NEW SOFTWARE R410A rcgroupairconditioning E C A C UP FLOW DOWN FLOW MAIN FEATURES Precision

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 81,1 TO 182 kw, AIRFLOW FROM TO m 3 /h

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 81,1 TO 182 kw, AIRFLOW FROM TO m 3 /h COMFORT ROOFTOP UNITS AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 81,1 TO 182 kw, AIRFLOW FROM 13500 TO 30500 m 3 /h ErP COMPLIANT climaveneta.com COMFORT ROOFTOP UNITS HIGHEST QUALITY IN EACH SINGLE

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units YORK YPRE RTR/RTP SERIES Air to air packaged rooftop units Cooling

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw COOLROW Close control air conditioners for In-Row installation Cooling Capacity: 14 61 Available in versions equipped with: - BLDC inverter scroll compressor on board of the unit - Chilled water feeding

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP EVH R-407C WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP Size Cooling Heating [kw] [kw] 7 2.0 1.9 11 2.6 2.5 15 3.9 3.3 5.2 5.5 25 7.3 6.7 31 8.9 8.4 41 10.7 9.8 REPLACE: BT02E009GB-01 The Versatemp

More information

www.ecso-klimatechnik.de ECSO GMBH Wetterssteimstr. 53 D- 90471,.. Nurnberg, Deutschland e-mail: info@ecso-klimatechnik.de Tel/Fax: +49 (0) 911/818 9917 TABLE OF SYMBOLS OPERATING MODE OPTIONS VENTILATION

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating. capacity: Heating capacity: 20,8 to 135,1 kw 22,6 to 144,7 kw Scroll compressors R-410A refrigerant Confi guration fl exibility Silent operation DESCRIPTION The AirDuo cooling units and are units which

More information

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation

More information

Roof top SPACE RPC 315Z R407C MA00

Roof top SPACE RPC 315Z R407C MA00 Client : TIHE SERV Contact : Romeo Staicu Your reference : Your contact : Phone : E-mail : Page : 1 / 6 Roof top SPACE RPC 315Z R407C MA00 Independant roof mounted unit, cooling only, ready to be installed,

More information

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB 4,5 22,5 kw Air-conditioned server-racks for direct installation into the room technicalcatalogue T_CLSEVO_0113_GB INDEX HIGHLIGHTS... 3 PLANT TYPE... 3 GENERAL CHARACTERISTICS... 5 SERIES IDENTIFICATION...

More information

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer

More information

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw Air cooled chillers with brushless oil-free compressors R-134a RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw External installation with very low sound level Cooling circuit with

More information

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS Total heat recovery multi-purpose units LCP Outdoor monobloc air-water unit LCP - kw Heating, cooling, domestic hot water one single system to meet all kinds of needs. Total heat recovery multi-purpose

More information

VERSO Air Handling Units

VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

HYDRONIC RESIDENTIAL

HYDRONIC RESIDENTIAL HYDRONIC RESIDENTIAL Chillers, reversible heat pumps and modular units for small and medium applications. Climaveneta. brand of Mitsubishi Electric Hydronics & IT Cooling Systems, presents the mini chiller

More information

ERACS.C-N Higher efficiency air-cooled screw pump

ERACS.C-N Higher efficiency air-cooled screw pump ELITE TM Series COOLING ERACS.C-N Higher efficiency air-cooled screw pump HEATING HOT WATER Cooling Capacity:5~1341 (7~381 Tons) Heating Capacity:60~1363 (74~388 Tons) High Efficiency Air-cooled Heat Pump

More information

CHAPTER 6 CONDENSING UNITS

CHAPTER 6 CONDENSING UNITS CHAPTER CONDENSING UNITS Unit Page MHA/K - MHA/K 8 0 - MRA/K 8-9 MRA/K 8 0 0 - FROM, KW TO KW. MHA/K AIRCOOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH AXIAL FANS AND ROTARY/SCROLL COMPRESSOR.

More information

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB 6 15 kw Next MTR Air conditioners for Metrology Labs with upflow air delivery technicalcatalogue T_NXTMTR_0511_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3

More information

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,

More information

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running Climaveneta Technical Bulletin BRH_0011_0121_201211_EN BRH r HFC R-410A 0011-0121 5,5-35,1 kw Water-cooled liquid chillers (The photo of the unit is indicative and may change depending on the model) Versatile

More information

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating Rooftop Ventilator with Packaged Cooling & Heating Models RV and RVE Institutional Commercial Industrial 800-1,500 cfm.0 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating Packaged

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

PRODUCT GUIDE

PRODUCT GUIDE PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency

More information

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018 New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1 Extensive option package included in all models ErP compliant 2018 3 years warranty Daikin rooftops Flexible to suit your application Rooftop for Retail & Department

More information

next DX.U.S* 052.Z2.H6.DC

next DX.U.S* 052.Z2.H6.DC next DX.U.S* 05.Z.H6.DC GENERAL CHARACTERISTICS Air conditioning unit with remote air cooled condenser, for computer rooms, any high-tech facility and offices. Units can run non-stop at 4x65 hours a year.

More information

Roof top SPACE RPC 450Z R407C M011

Roof top SPACE RPC 450Z R407C M011 Roof top SPACE RPC 450Z R407C M011 Page : 1 / 5 Independant roof mounted unit, cooling only, ready to be installed, designed for air conditioning of large volumes for industrial or commercial use. As per

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative

More information

AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw

AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw PROCESS CHILLERS HEAT PUMPS AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION 17-290 kw climaveneta.com PROCESS CHILLERS HEAT PUMPS A TRULY UNIQUE SOLUTION

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65% Dry HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES Calculation of savings (for illustrative purposes) Operating scheme Note: power rates refer to 10,000 m 3 /h of air and

More information

RFA TECHNICAL MANUAL SINGLE PACKAGED ROOFTOP UNITS ROOF-TOP. Mod

RFA TECHNICAL MANUAL SINGLE PACKAGED ROOFTOP UNITS ROOF-TOP. Mod RFA SINGLE PACKAGED ROOFTOP UNITS ROOF-TOP 34.4 9.8 kw in cooling mode 38.6 117.8 kw in heating mode DOZONE SAVE Mod. 35.1 45.1 55.1 70.2 90.2 1.2 TECHNICAL MANUAL TABLE OF CONTENTS GENERAL FEATURES................................................................................

More information

NECS. Climaveneta Technical Bulletin. Air-cooled water chillers with axial fans. 0202T T kw

NECS. Climaveneta Technical Bulletin. Air-cooled water chillers with axial fans. 0202T T kw Climaveneta Technical Bulletin _0202T_0612T_200912_GB r HFC R-410A 0202T - 0612T 53-159 kw Air-cooled water chillers with axial fans (The photo of the unit is indicative and may change depending on the

More information

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SERIES: WCHZ MODELS: 201, 251, 271, 351, 401, 501, 701, 721, 751 COOLING CAPACITIES OF: 6,4

More information

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme

More information

VERSO Air Handling Units

VERSO Air Handling Units VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P

More information

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable

More information

next p dw next p dw rcgroupairconditioning

next p dw next p dw rcgroupairconditioning NEXT P: Heat pump air conditioners with upflow air delivery with built-in water/gas exhaustion heat exchanger Cooling Capacity: 7,5 7,0 Heating Capacity: 7, 04,0 A C rcgroupairconditioning R40A PLATE E

More information

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS

More information

YORK Close Control units

YORK Close Control units york air-conditioning products YORK Close Control units Maintaining a constant temperature, purity and humidity of air is essential for ensuring a stable environment for critical electronic and computer

More information

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Quality Management Systems 30RBY/RQY 017-033 Nominal cooling capacity 15-33 kw Nominal heating capacity 17-31 kw The new

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

Blue Box Epsilon Echos +

Blue Box Epsilon Echos + Blue Box Epsilon Echos + 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Packaged version in 5 sizes Nominal cooling capacity (A35;W7): 6 26 kw Nominal heating

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

K Series Modular air conditioners. With direct expansion coil With chilled water coil

K Series Modular air conditioners. With direct expansion coil With chilled water coil K Series Modular air conditioners With direct expansion coil With chilled water coil K Series Modular air conditioners With direct expansion coil With chilled water coil Designed for precision and comfort

More information

Precision air handling cabinets Ciatronic MICRO/EXPAIR

Precision air handling cabinets Ciatronic MICRO/EXPAIR / Reducted footprint Double-wall construction Built-in voltage variator PLC control Variable speed condenser fan ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity: 5 to

More information

GHE Dehumidifiers for radiant cooling systems with heat recovery

GHE Dehumidifiers for radiant cooling systems with heat recovery Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures

More information

ELFOEnergy Extended Inverter

ELFOEnergy Extended Inverter Technical Bulletin BT14F009GB-03 ELFOEnergy Extended Inverter AIR-COOLED INVERTER CHILLER FOR OUTDOOR INSTALLATION WSAT-XIN 21-171 RANGE PREMIUM Version Nominal cooling capacity (A35/W7) from 4 to 30 kw

More information

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range is an efficient and low-noise product designed for medium to big applications. The water chillers are suitable for water outlet temperatures

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

FOCS. Climaveneta Technical Bulletin FOCS_0751_1301_200909_GB. Air-cooled water chiller with helical fans kw

FOCS. Climaveneta Technical Bulletin FOCS_0751_1301_200909_GB. Air-cooled water chiller with helical fans kw Climaveneta Technical Bulletin _0751_1301_200909_GB 0751-1301 145-516 kw Air-cooled water chiller with helical fans (The photo of the unit is indicative and may change depending on the model) Flexibility

More information

THE ULTIMATE ROOFTOP SOLUTION

THE ULTIMATE ROOFTOP SOLUTION Configured Packaged Rooftop Solutions Specializing in Dedicated Outdoor Air Systems (DOAS) Capacities from 6 to 90 Tons Available in 208, 230, 460 and 575 Volts THE ULTIMATE ROOFTOP SOLUTION Service Friendly

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42 SELF CONTAINED HORIZONTAL UNITS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER ) HEAT PUMP. WCHBZ COOLING ONLY. WCHZ SERIES: WCHBZ - Heat Pump MODELS: 201, 251, 271, 351, 401, 501 COOLING

More information

ELFOEnergy Duct Inverter

ELFOEnergy Duct Inverter Technical Bulletin BT14E002GB-02(EC1) ELFOEnergy Duct Inverter Air-water ductable liquid chiller for indoor or outdoor installation SERIES WSA-XIN 21-141 Nominal cooling capacity (A35/W7) da 4 a 31 kw

More information

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features: RL Packaged Rooftop Units, heat pumps and Outdoor air handling Units Features: Air-cooled condenser, water-cooled condenser, or patented AAON evaporative-cooled condenser, with capacities from 45-240 tons

More information

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information

The integral solution for. Air Handling Units. Technology & Evolution

The integral solution for. Air Handling Units. Technology & Evolution The integral solution for Air Handling Units Technology & Evolution For over 25 years Carel has been dealing with the design and production of electronic controllers and supervision systems for Air-Conditioning

More information

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual u Air-to-Water Reverse Cycle Heat Pumps AQH 40 to 130 40 to 131 kw 45 to 141 kw Engineering Data Manual EDM AQH-W.3GB Date : November 2007 Supersedes : TM AQH-W.2GB/03.04 Specifications The Aqu@Logic air-to-water

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information