Flygt 3153, 3171, 3202, 3301, 3315, 5100, Replacing Cooling Liquid In Pumps with Cooling Jackets
|
|
- Myra Francis
- 5 years ago
- Views:
Transcription
1 Flygt 3153, 3171, 3202, 3301, 3315, 5100, 5150 Replacing Cooling Liquid In Pumps with Cooling Jackets
2
3 Table of Contents Table of Contents 1 Replace the Cooling Liquid Prerequisites The water-glycol mixture Coolant and inspection plugs Depressurize the cooling jacket Empty the cooling jacket Empty the cooling liquid in the inspection chamber Fill with cooling liquid, alternative 1: complete pump Fill with cooling liquid, alternative 2: drive unit... 6 Flygt 3153, 3171, 3202, 3301, 3315, 5100, 5150 Replacing Cooling Liquid In Pumps with Cooling Jackets 1
4 1 Replace the Cooling Liquid 1 Replace the Cooling Liquid 1.1 Prerequisites The old (spent) cooling liquid can be highly alkali. Use chemical eye goggles and rubber gloves, and other appropriate personal protective equipment. For T- and Z-installations, the inlet and outlet lines must be closed off before starting work, and the piping system must be depressurized. See the Installation, Operation and Maintenance manual for the pump. Ensure adequate ventilation in the workspace. It is very important that the cooling system is depressurized before the drive unit is separated from the pump housing. See Depressurize the cooling jacket (page 3). For general safety Before starting work, make sure that the safety instructions in the Installation, Operation and Maintenance manual for the pump have been read and understood The water-glycol mixture Composition Use a cooling liquid that is a mixture of 70% deionized or distilled water, and 30% DOWCAL 200 monopropylene glycol. If DOWCAL 200 from Dow Chemical Company is not available, then contact your local Xylem representative. NOTICE: Deionized or distilled water must be used in the water-glycol mixture. Applications for potable water or ingested substances Volume of water-glycol mixture If the pumped liquid includes potable water or substances to be ingested, then contact your local Xylem sales representative. Pump (11.2) /.095/.181/.185/.350/.390/.660/ (17.6) /.810/.820/.830/.840/.850/.860/ (25.4) /.095/.180./185/.350/.390/.660/ (26.4) /.810/.820/.830/.840/.850/.860/ (43.3) /.095/.180/.185/.660/ (49.6) /.810/.820/.830/.860/ (57) (54.9) / (11.2) / (17.6) / (26.4) / (26.4) / (49.6) 1.2 Coolant and inspection plugs Quantity of water-glycol mixture, L (qt.) This image shows the plugs that are used to change the cooling liquid. 2 Flygt 3153, 3171, 3202, 3301, 3315, 5100, 5150 Replacing Cooling Liquid In Pumps with Cooling Jackets
5 1 Replace the Cooling Liquid WS001479A 1. Inspection plug 2. Coolant plugs 1.3 Depressurize the cooling jacket WARNING: Flammable Gas The chamber might contain hydrogen gas, which is flammable. Avoid sparking, electrical tools, and other sources of ignition. CAUTION: Chemical Hazard The old (spent) liquid can be highly alkali and cause caustic burns. Wear suitable gloves and chemical eye goggles or face shield. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. CAUTION: Compressed Gas Hazard Air inside the chamber may cause parts or liquid to be propelled with force. Be careful when opening. Do not stand in front of the plug. 1. Partially unscrew the uppermost coolant plug. Unscrew 2 turns only. x 2 WS009488A 2. Push inwards on the coolant plug. If there is resistance, then wait for the built-up pressure inside the cooling jacket to vent. WS009487B Flygt 3153, 3171, 3202, 3301, 3315, 5100, 5150 Replacing Cooling Liquid In Pumps with Cooling Jackets 3
6 1 Replace the Cooling Liquid 3. Push on the coolant plug again. If it is loose and has no resistance, then the pressure has been vented. Continue with the next step. 4. Re-install the coolant plug. 1.4 Empty the cooling jacket NOTICE: It is important that all of the old (spent) cooling liquid is drained. For T- and Z-installations it is necessary to remove the drive unit from the pump housing. For P- and S-installations the drive unit does not need to be separated from the pump housing. The quantity of cooling liquid can be significant. Have a container available to collect any liquid coming out. For cooling liquid volumes, see The water-glycol mixture (page 2). 1. If it is necessary to separate the drive unit from the hydraulic unit, then follow this procedure: a) Relieve any built-up pressure inside the cooling jacket. See Depressurize the cooling jacket (page 3). b) Remove the pump housing screws. c) Remove the drive unit from the pump housing. NOTICE: Do not allow the weight of the pump to rest on any portion of the impeller. The impeller must not be allowed to make contact with the concrete floor or other hard or rough surfaces. 2. Place the pump horizontally, so that one of the coolant plugs is at the lowest point of the pump, to ensure that the cooling liquid will drain completely. It is important to empty all of the cooling liquid. 3. Place a container under the pump. 4. Remove the coolant plugs and empty the cooling liquid. 4 Flygt 3153, 3171, 3202, 3301, 3315, 5100, 5150 Replacing Cooling Liquid In Pumps with Cooling Jackets
7 1 Replace the Cooling Liquid WS001411A 1.5 Empty the cooling liquid in the inspection chamber CAUTION: Compressed Gas Hazard Air inside the chamber may cause parts or liquid to be propelled with force. Be careful when opening. Hold a rag over the plug to prevent liquid from spraying out. 1. Place the pump in a vertical position. Secure it so that it cannot tip or fall. 2. Remove the inspection plug. WS002122B 3. Pump out any cooling liquid from the inspection chamber, as shown here. Flygt 3153, 3171, 3202, 3301, 3315, 5100, 5150 Replacing Cooling Liquid In Pumps with Cooling Jackets 5
8 1 Replace the Cooling Liquid WS009196B 4. Fit a new O-ring and re-install the inspection plug. Tighten the plug. Tightening torque: 44 Nm (33 ft-lbs) 1.6 Fill with cooling liquid, alternative 1: complete pump Follow these instructions if the drive unit has not been separated from the pump housing. 1. Put the pump in a vertical position. Secure the pump so that it cannot tip or fall. 2. Fill with cooling liquid until it overflows through the opposite hole, as shown here. For cooling liquid amount, see The water-glycol mixture (page 2). WS000966A 3. Fit new O-rings and re-install the coolant plugs. Tighten the plugs. Tightening torque: 44 Nm (33 ft-lb) 4. Re-install the pump in its correct position. 1.7 Fill with cooling liquid, alternative 2: drive unit If the drive unit has been separated from the pump housing then follow these instructions. 1. Put the drive unit in a vertical position. Secure the drive unit so that it cannot tip or fall. NOTICE: Do not allow the weight of the pump to rest on any portion of the impeller. The impeller must not be allowed to make contact with the concrete floor or other hard or rough surfaces. 2. Fill with cooling liquid until it overflows through the opposite hole, as shown here. For cooling liquid amount, see The water-glycol mixture (page 2). 6 Flygt 3153, 3171, 3202, 3301, 3315, 5100, 5150 Replacing Cooling Liquid In Pumps with Cooling Jackets
9 1 Replace the Cooling Liquid WS000966A 3. Fit new O-rings and reinstall the coolant plugs. Tighten the plugs. Tightening torque: 44 Nm (33 ft-lb) 4. Reinstall the drive unit onto the pump housing. 5. Complete the reinstallation of the pump. Flygt 3153, 3171, 3202, 3301, 3315, 5100, 5150 Replacing Cooling Liquid In Pumps with Cooling Jackets 7
10
11
12 Xylem zīləm 1) The tissue in plants that brings water upward from the roots 2) A leading global water technology company We re a global team unified in a common purpose: creating innovative solutions to meet our world's water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to xyleminc.com Refer to for contact details of your local sales and service representative. Xylem Water Solutions Global Services AB Emmaboda Sweden Tel: Fax: Visit our Web site for the latest version of this document and more information The original instruction is in English. All non-english instructions are translations of the original instruction Xylem Inc enUS_1.0_en-US_ _CLC.Flygt
Lenntech. Tel Fax bar. Multistage Pumps.
Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 100 bar Multistage Pumps Vogel Series MPE Technical Data Performance Range: m Capacity up to 300m 3 /h (1320USgpm)
More informationBlockpumps. Vogel Series LSB. Lenntech. Tel Fax
Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Blockpumps Vogel Series LSB WITH HYDRAULICS ACCORDING TO ISO 2858 Technical Data Performance: m Capacity up to 450m
More informationEcocirc D5vario DC pumps DIRECT OR BATTERY POWERED FROM 8-24 VOLT, WITH SPEED CONTROL
Ecocirc D5vario DC pumps DIRECT OR BATTERY POWERED FROM 8-24 VOLT, WITH SPEED CONTROL Ecocirc D5vario design Stator / motor with red speed controller in the end cap Screw ring Ceramic bearing ball Gasket
More informationVolute Casing Pumps. Vogel Series LN/L ACCORDING TO EN 733 DE: +41 (0) FR: +41 (0)
Volute Casing Pumps Vogel Series LN/L ACCORDING TO EN 733 DE: +41 (0)31 721 52 24 FR: +41 (0)21 905 10 80 Technical Data Performance: m Capacity up to 600m 3 /h (2640USgpm) m Head up to 100m (330feet)
More informationInline Pumps LR/LMR & LRZ/LMZ, LER & LEZ. Lenntech. Tel Fax
Inline Pumps LR/LMR & LRZ/LMZ, LER & LEZ Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Design LR, LMR Technical Data Performance: m Capacity up to 350m 3 /h (1540USgpm)
More informationGENYO Series ELECTRIC PUMP CONTROL AND PROTECTION SYSTEM
GENYO Series ELECTRIC PUMP CONTROL AND PROTECTION SYSTEM Electric pump control and protection system 02 Applications. Domestic pressure boosting (single and multi-family dwellings) Small irrigation and
More informationSewage Pumps. KS - Channel Type Pumps W, WTS - Vortex Type Pumps
Sewage Pumps KS - Channel Type Pumps W, WTS - Vortex Type Pumps Design KS Technical Data Performance Range: m Capacity up to 500m 3 /h (2200USgpm) m Head up to 45m (150feet) m Speed up to 1450rpm Sizes:
More informationFlygt MAS 711. Monitoring system for Flygt pumps
Flygt MAS 711 Monitoring system for Flygt pumps The monitoring system that remembers and records Flygt MAS 711 is a pump monitoring system design ed to remember, record and present pump events fast and
More informationAutomatic Water System Pump SERIES
Automatic Water System Pump 42755 SERIES Automatic Water System Pump Purpose of this manual The purpose of this manual is to provide necessary information for product installation, operation and maintenance.
More informationBMW E36 Thermostat Removal And Coolant Flush
BMW E36 Thermostat Removal And Coolant Flush Disclaimer: The cooling system is critical to the proper operation of your car. Failure to properly install all of the components of the cooling system could
More informationWATER PUMP REQUESTED INFORMATION STANDARD PROCEDURE RAM Pickup 6.7L Eng 2500 STANDARD PROCEDURE - COOLANT AIR EVACUATION
WATER PUMP 2012 RAM Pickup 6.7L Eng 2500 REQUESTED INFORMATION STANDARD PROCEDURE STANDARD PROCEDURE - COOLANT AIR EVACUATION Fig 1: Pressurized Air Operated Vacuum Generator Evacuating or purging air
More informationLowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY
NE W Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY Ecocirc_Premium_uk.indd 1 28/10/13 12.26 How can efficiency even w The simple spherical
More informationInstallation, Operation, and Maintenance Manual. NRF -25,36,45/NBF -25,36, and 45 Circulator
Installation, Operation, and Maintenance Manual NRF -25,36,45/NBF -25,36, and 45 Circulator Table of Contents Table of Contents Introduction and Safety...2 Introduction...2 Requesting other information...2
More informationNEW Lowara ecocirc PRO The new high efficiency domestic hot water PumPs with automatic air venting function and TheRmaL insulation shell
NEW Lowara ecocirc PRO The new high efficiency domestic hot water pumps with automatic air venting function and thermal insulation shell ecocirc PRO domestic hot water circulation pumps. Areas of use.
More information6. COOLING SYSTEM 6-0 COOLING SYSTEM MXU 500
6 COOLING SYSTEM SYSTEM FLOW PATTERN----------------------------------------------- 6-1 SERVICE INFORMATION------------------------------------------------ 6-2 TROUBLESHOOTING-----------------------------------------------------
More informationFlygt Top-Entry Agitators CONVENIENT AND EFFICIENT
Flygt Top-Entry Agitators CONVENIENT AND EFFICIENT INTRODUCTION Top energy-efficient performance Advantages of Flygt top-entry agitators Rising to the mixing challenge All mixing applications require varying
More informationImpeller Stack Kit Dismantling and Reassembly CR(I/N) 1S 1 3 5
GRUNDFOS CR Series Impeller Stack Kit Dismantling and Reassembly CR(I/N) 1S 1 5 Grundfos Pumps Corporation 17100 W. 118th Terrace Olathe, Kansas 66062 Telephone: 91.227.00 Fax: 91.227.500 www.grundfos.com
More informationDomestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit
Custom engineered units to maintain optimum boiler levels and system vacuum requirements Four styles to choose from to minimize floor space requirements Multi-jet vacuum pumps for quiet, dependable and
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Accessory Application Publications No. ENGINE BLOCK P/N 08T44-SNA-100 2008 MDX BII 37679 Issue Date AUG 2007 PARTS LIST Engine block heater Aluminum washer Heater harness Protective
More informationDomestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.
Cast Iron Receivers: For years of dependable service; warranted for 20 years from date of shipment against failure due to corrosion. Each Receiver comes standard with Inlet connection, an overflow and
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Accessory Application Publications No. ENGINE BLOCK P/N 08T44-SNA-100 2007 MDX BII 32728 Issue Date OCT 2006 PARTS LIST Engine block heater Aluminum washer Heater harness Protective
More informationLowara ecocirc and ecocirc PREMIUM
Lowara and PREMIUM THE REVOLUTIONARY HIGH EFFICIENCY CIRCULATORS FOR DOMESTIC HEATING WITH THE SIMPLE AND SHAFTLESS SPHERICAL MOTOR DESIGN AND PATENTED ANTI-BLOCK TECHNOLOGY How can efficiency work even
More informationUser s Guide REO-MECH. Industrial Rebar Benders & Cutters
User s Guide REO-MECH Industrial Rebar Benders & Cutters WARNING: PLEASE READ THIS MANUAL CAREFULLY BEFORE USING THIS MACHINE Machine is not rated and should not be used for commercial rebar production
More informationInstruction Sheet. VIQUA UVMAX Lamp and Quartz Sleeve Replacement
VIQUA UVMAX Lamp and Quartz Sleeve Replacement Models: H, K, H+, K+, PRO0, PRO0, PRO0 and PRO50 Overview Instruction Sheet UV Lamp replacement: The amount of UV light created by the UV lamp decreases over
More information6. Cooling System XCITING 400i. This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i.
6. Cooling System XCITING 400i Cooling System This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i. Coolant... 6-3~6-11 Radiator... 6-12~6-23 Thermostat...
More informationHumidifier De-scaling Solution. and Neutralizer. Usage Instructions. IMPORTANT: Read and save these instructions. Before
IMPORTANT: Read and save these instructions. Humidifier De-scaling Solution and Neutralizer Usage Instructions Before Humidifier De-scaling Solution After Humidifier De-scaling Solution S a f e t y i n
More informationWEDECO Quadron UV System
WEDECO Quadron UV System reliable UV disinfection from every angle WEDECO Quadron UV System The deactivation of bacteria, viruses and parasites with the help of ultraviolet (UV) light is a triedand-tested
More informationExtended Range. PRESFIX Packaged Pressurisation Sets AUTOMATIC MAKE-UP UNITS FOR SEALED HEATING AND CHILLED WATER SYSTEMS.
Extended Range PRESFIX Packaged Pressurisation Sets AUTOMATIC MAKE-UP UNITS FOR SEALED HEATING AND CHILLED WATER SYSTEMS. 2 Presfix Beta MK 2 microprocessor single & twin pump unit Heating system Chilled
More informationHydroFlux Welder Torch System T0-102 / T0-103
HydroFlux Welder Torch System T0-102 / T0-103 Setting Up The HydroFlux 1. Location - The HydroFlux Welder must be placed on a level surface with adequate ventilation. We recommend a minimum of 4 inches
More informationCOOLING SYSTEM. Page CO-2 TROUBLESHOOTING... CO-4 CHECK AND REPLACEMEANT OF ENGINE COOLANT... WATER PUMP... DESCRIPTION...
COOLING SYSTEM DESCRIPTION... Page CO-2 TROUBLESHOOTING... CO-4 CHECK AND REPLACEMEANT OF ENGINE COOLANT... WATER PUMP... CO-5 CO-6 THERMOSTAT... CO-8 RADIATOR... CO-9 CO-2 COOLING SYSTEM - Description
More informationDetailed Cleaning Instructions
NY Thermal Inc. Tel: (06) 67-6000 Toll Free: 1-800-688-27 Fax: 1-06-432-113 Web: www.ntiboilersl.com Email: info@ntiboilers.com Style Heat Exchanger occupants or, death. This boiler must be serviced by
More informationUV Lamp and Quartz Sleeve Replacement/Maintenance
UV Lamp and Quartz Sleeve Replacement/Maintenance Models: Tap, Tap Plus, Home, Home Plus, Professional, Professional Plus (Excluding, D4, E4, F4, and Plus and Monitored versions) Overview UV Lamp replacement:
More information50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC
/ Hz ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS ErP 9//EC Cod. 9 Rev. C Ed./ ecocirc BASIC SERIES INSTALLATION POSITIONS Lowara, ecocirc, Xylect are trademarks
More information489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationUser Manual. Rev Please read and understand all instructions before use. Retain this manual for future reference.
TM EasyMining RCR6 Rock Crusher with ExDustVacTM Dust Vacuum System User Manual Rev. 1.4 Please read and understand all instructions before use. Retain this manual for future reference. Download the latest
More informationOPERATING MANUAL. ba75825e03 12/2015 LR 925/01 LR 925/01-P LR 925/01(-P) ULTRAPURE WATER CONDUCTIVITY MEASURING CELL
OPERATING MANUAL ba75825e03 12/2015 LR 925/01 LR 925/01-P ULTRAPURE WATER CONDUCTIVITY MEASURING CELL Copyright 2016 Xylem Analytics Germany GmbH Printed in Germany. Contents - Contents 1 Overview.........................................
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Accessory ENGINE BLOCK Application 2010 INSIGHT Publications No. AII 40879 Issue Date MARCH 2009 PARTS LIST Engine Block Heater Kit P/N 08T44-SNA-101 Engine block heater Engine
More informationIDT-12-N Hydraulic Crimping Tool
INSTRUCTION MANUAL IDT-12-N Hydraulic Crimping Tool Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. 99945282 REV 6 2009 Ilsco
More informationSPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000
SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000 TM INSTALLATION AND OWNER S MANUAL C O N T E N T S I. Introduction II. Product Dimensions III. Installation IV. Operation in Emergency Situation V. Periodic
More informationSPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000
SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000 TM INSTALLATION AND OWNER S MANUAL C O N T E N T S I. Introduction II. Product Dimensions III. Installation IV. Operation in Emergency Situation V. Periodic
More informationDEPARTMENTAL SAFETY ISSUES - SAFETY TECHNOLOGIST / INFECTION CONTROL PRACTITIONER
Section: Orientation For Technologists Manual Policy # MI\ORIEN\03\03\v01 Page 1 of 2 Subject Title: Departmental Issues - Technologist/Infection Control Practitioner Issued by: LABORATORY MANAGER Original
More informationEdition 8 From serial no Publ. no OM 5030NHD; Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL)
Edition 8 From serial no. 106000- Publ. no 4869701-00 OM 5030NHD; 2012-02 Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL) English CONTENTS Safety...8 2 Operating instructions...9 3 Technical specifications...10
More informationCBT Bowl & wrap replacement
CBT bowl & wrap replacement 2 CBT BOWL & WRAP REPLACEMENT Revision History rev. level 01_03.14.2012 rev. level 02_03.19.2012 rev. level 03_03.23.2012 rev. level 04_05.30.2013 NOTE: due to the fact that
More information569, 570, 571, 572 Series
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationInstallation instructions Air drying unit for Bubble Sensor OTT CBS. English
Installation instructions Air drying unit for Bubble Sensor OTT CBS English 1 Scope of supply Air drying unit 1 air drying unit with 400 gram drying medium, air humidity indicator and mounting bracket
More informationREAD AND SAVE THESE INSTRUCTIONS DE-SCALING SOLUTION. Humidifier De-scaling Solution and Neutralizer. Usage Instructions
READ AND SAVE THESE INSTRUCTIONS DE-SCALING SOLUTION Humidifier De-scaling Solution and Neutralizer Usage Instructions Safety instructions HUMIDIFIER DE-SCALING SOLUTION HUMIDIFIER DE-SCALING NEUTRALIZER
More informationInstruction Sheet DANGER
VIQUA Lamp and Quartz Sleeve Replacement Models: D4, E4, F4, D4 Premium, Plus Models Discontinued Models: A, B, C, D, E, F, B4, C4 Overview UV Lamp replacement: The amount of UV light created by the UV
More information569, 570, 571, 572 Series
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationInstruction Sheet DANGER
VIQUA Lamp and Quartz Sleeve Replacement Models: D4, E4, F4, D4 Premium, Plus Models Discontinued Models: A, B, C, D, E, F, B4, C4 Overview UV Lamp replacement: The amount of UV light created by the UV
More informationLowara ecocirc and ecocirc PREMIUM
Lowara and PREMIUM THE REVOLUTIONARY HIGHLY EFFICIENT CIRCULATORS FOR DOMESTIC HEATING WITH THE SIMPLE AND SHAFTLESS SPHERICAL MOTOR DESIGN AND PATENTED ANTI-BLOCK TECHNOLOGY How can efficiency work The
More informationFACSCalibur Startup Procedures
FACSCalibur Startup Procedures Always turn on the FACSCalibur before turning on the computer when acquiring data. This enables the computer to recognize that the cytometer is connected. When analyzing
More informationSafety Instructions For Your
Safety Instructions For Your SPARTAN Cable Machines SPARTAN TOOL L.L.C. 1506 W. Division Street Mendota, IL 61342 800.435.3866 Fax 815.539.9786 44163000 (Rev. B) 4-13-07 www.spartantool.com 2007 Spartan
More informationDURANGO 12V Heater HF
DURANGO 12V Heater HF-100012 1 Product description 2 Operating principle 3 Mounting recommendations 4 Troubleshooting 3 Safety instructions Page 1 of 5 1 Product description The DURANGO heater consists
More informationReplacing a Gun Thermostat
Instruction Sheet Replacing a Gun Thermostat WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation.
More informationSymphony Plus Pressurized Water Sanitizing Kit P/N
For use with systems with no filter Symphony Plus Pressurized Water Sanitizing Kit P/N 01089580 Installation Instructions ATTENTION! These instructions are for Symphony Plus dispensers only. Instructions
More informationHWX GAS BOILERS USER S INFORMATION MANUAL
UMHWX3-1 22-UMHWX3 HWX GAS BOILERS USER S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury
More informationSUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION
SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION Thank you for selecting an Aqua Logic, Inc. Ultraviolet (UV) Sterilizer. Each model has been designed and built to provide years
More informationS water = J/gC
EXPERIMENT 7 Specific Heat Capacity of A Metal INTRODUCTION One of the properties of matter is that it requires a certain amount of heat energy to raise the temperature of a unit mass of a substance. This
More informationThermostat Cold Air Evaporator
Chart Thermostat Cold Air Evaporator 4 Expansion Valve 5 Evaporator Blower 6 Compressor Condenser Sight Glass Pressure Switch Fan Desiccant 3 Receiver Drier High Pressure Gas High Pressure Liquid Low Pressure
More informationModels Series Series
Models 3180-Series 3181-Series INDUSTRIAL DIAPHRAGM PUMPS Commercial Duty, 3 GPM/1 LPM FEATURES Sealless Easy Installation Run Dry Ability Flow to 3 GPM/1 LPM Self-Priming Low Amp Draw Thermal Overload
More informationInstallation, Operation and Maintenance Manual
Installation, Operation and Maintenance Manual Packaged Chiller Models CC 6601, 6501, 6401, 6301, 6201, 6101 For Service, please contact Pfannenberg Service Company: U.S.A. Pfannenberg Inc. 68 Ward Road.
More informationCascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions
Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions PENNER PATIENT CARE, INC Box 523 / 101 Grant St. Aurora, NE 68818 560750 Revision A 12/11/15 1-866-PENNERS
More informationInstallation Guide. Inline Chlorinator TM. Vitasalus, Inc Rankin Drive Troy, Michigan USA
Vitasalus, Inc. 248-585-8815 1301 Rankin Drive Troy, Michigan 48083 USA www.vitasalus.com Congratulations on your purchase of the Water Treatment and Disinfection System, an effective easy to use chorine
More informationOperating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage
Model: 1090 1 Safety instructions Float-Controlled Condensate Trap, PN 16 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination
More informationOWNER S MANUAL (English)
TR600 Series Refrigerant Recovery Machines OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TR600, TR610, TR600C, TR610C, TR600S, TR600K, TR600E TO BE
More informationHeaters and Defrosters
Heaters and Defrosters Table of Contents Sub-Headings Safety 2 Warnings 2 Cautions 2 s 2 Introduction 2 General Specifications 2 ISB Engine 2 Coolant Specification 3 Description of Operation 3 Heater Access
More informationCF35 # INSTALLATION & OPERATION
CF35 #80046677 INSTALLATION & OPERATION PICTOGRAMS Each Signifier displayed here is specific to this User Manual. Menu Previous Advance Note Tip Example 35 kg Safety Warnings System Diagram Installation
More informationV-220 / V-320 Heater Kits Installation Instructions TK IM (Rev. 0, 06/17)
Installation Manual V-220 / V-320 Heater Kits Installation Instructions TK 56340-18-IM (Rev. 0, 06/17) Installation Manual V-220 / V-320 Heater Kits Installation Instructions TK 56340-18-IM (Rev. 0, 06/17)
More informationINSTALLATION & MAINTENANCE
INSTALLATION & MAINTENANCE MODELS: UVG SLT 2 (GT7-2UVG) UVG SLT 30 (GT7-4UVG) UVG SLT 40 (GT7-8UVG) UVG SLT 75 (GT7-13UVG) UVG SLT80 UVG SLT125 (GT7-15UVG) and UVG SLT 172 Stainless Steel Water Disinfection
More informationUser s Guide REO-MECH. RB-16 Electric Rebar Bender
User s Guide REO-MECH RB-16 Electric Rebar Bender WARNING: PLEASE READ THIS MANUAL CAREFULLY BEFORE USING THIS MACHINE Machine is not rated and should not be used for commercial rebar production purposes.
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL Advantage DV GAS - FIRED BOILER WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or
More informationGESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45
GESTRA Steam Systems DK 45 EN English Installation Instructions 818676-00 Steam Trap DK 45 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED
More informationOperating Instructions
Operating Instructions BA-003 Read and understand this manual before use. Keep this manual for future reference. CONFORMS TO UL STD.No.1017 Certified to CSA STD C22.2 No.243-10 For questions or concerns
More informationTECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories
TECHNICAL BROCHURE BCALARM R4 Indoor and Outdoor Panels and Accessories FEATURES Indoor and Outdoor alarm panels for sump, effluent and wastewater systems as well as test panel for troubleshooting. Use
More informationSMK 22 SMK SMK SMK 22-82
GESTRA Steam Systems SMK 22 SMK 22-51 SMK 22-81 SMK 22-82 EN English Installation Instructions 810481-04 Steam Traps SMK 22, SMK 22-51, SMK 22-81, SMK 22-82 1 Contents Title Page Title page...1 Inhalt
More informationHOT WASHER MODEL NO: KING150
WARNING: Do not use the hot washer without reading this manual HOT WASHER MODEL NO: KING150 PART NO: 7320175 OPERATION & MAINTENANCE INSTRUCTIONS LS1215 INTRODUCTION Thank you for purchasing this CLARKE
More information4 TON HYDRAULIC FLOOR PRESS INSTRUCTION MANUEL
4 TON HYDRAULIC FLOOR PRESS INSTRUCTION MANUEL Make sure read and fully understand the instruction manual before using the product IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFETY INSTRUCTIONS
More informationPatterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationCLS-1450 Series Spinner Flask Instruction Manual
CLS-1450 Series Spinner Flask Instruction Manual Chemglass Life Sciences 3800 North Mill Road Vineland, NJ 08360 USA Phone: 800-843-1794 Email: customer-service@cglifesciences.com Web address: www.cglifesciences.com
More informationClimate Control System
Page 1 of 13 SECTION 412-00: Climate Control System General Information DESCRIPTION AND OPERATION 1998 Mark VIII Workshop Manual Climate Control System Cautions and Warnings WARNING: To avoid accidental
More informationPatterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationMODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)
MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS) FOR PROPER AND SAFE USE OF THIS CHEMCHAMP EQUIPMENT, PLEASE FOLLOW THIS DOCUMENT AND LOCAL AUTHORITY. KEEP THIS DOCUMENT FOR FUTURE REFERENCE.
More informationB.) Accident -- Any suddenly occurring unintentional event which causes injury or property damage.
Staunton River High School Technology Education Bedford County Public Schools Terms and Definitions Terms and Definitions A.) Safety State or condition of being safe; freedom from danger, risk or injury.
More informationMaterial Safety Data Sheet according to Regulation (EC) No. 1907/2006. Composition/Information on Ingredients
Version 2.16 Material Safety Data Sheet according to Regulation (EC) No. 1907/2006 Part 1 Silica gel E orange Information to the supplier/distributor Giebel FilTec GmbH Carl-Zeiss-Str. 5 DE-74626 Bretzfeld-Schwabbach
More informationPatterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationGrinding mill MISTRAL 50L (art. 650P)
Grinding mill MISTRAL 50L (art. 650P) USE AND MAINTENANCE MANUAL RIVER SYSTEMS SRL Via Marco Polo, 33-35011 Campodarsego (Padova) Italy Tel. +39-049-9202464 - Fax: +39-049-9216057 - e-mail: info@riversystems.it
More informationModels Series Series
Models 31800-Series 31801-Series INDUSTRIAL DIAPHRAGM PUMPS 4 GPM/15 LPM FEATURES Self-Priming Easy Installation Can run dry without damage Low Amp Draw Flow to 4 GPM/15 LPM Compact Size Thermal Overload
More informationModel: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100
1 Safety instructions Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead
More informationQuadron UV Series. Sustainable UV Disinfection with Minimum Footprint
Quadron UV Series Sustainable UV Disinfection with Minimum Footprint Exceeding Reliability, Reducing Footprint Xylem s Wedeco Quadron is the treatment experts choice when looking for a proven UV disinfection
More informationPME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies
PME Series Enclosures Battery Enclosure (BE) Field Upgrade Installation Instructions Effective: January, 2004 Alpha Technologies Power Alpha Technologies. Protecting The Power in Communications. Preface
More information! WARNING. Style # Laguna Ventless Rectangle Fire Table Owner s Manual. Restoration Hardware Customer Service:
Lot: PO: Style # 600 Laguna Ventless Rectangle Fire Table Owner s Manual For Technical Support call -800-65-70 Designed and Engineered by Real Flame. Manufactured in China for: Restoration Hardware 5 Koch
More informationHeater for BRP Commander. Caution: Before using this product, read this manual and follow all safety instructions. Owner s Manual
Owner s Manual Model: Can Am Commander Heater for BRP Commander Caution: Before using this product, read this manual and follow all safety instructions. Safety Instructions Kit Contents Tool Requirement
More informationENGLISH (Original instructions) INSTRUCTION MANUAL. Demolition Hammer HM0810TA DOUBLE INSULATION. IMPORTANT: Read Before Using.
ENGLISH (Original instructions) INSTRUCTION MANUAL Demolition Hammer HM080TA 00079 DOUBLE INSULATION IMPORTANT: Read Before Using. ENGLISH (Original instructions) SPECIFICATIONS Model HM080TA Blows per
More informationDyna-Star HP or HF Pump 35# Pail Kit and Follower Plate
Instructions Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate 332517B EN For adapting a 60# Dyna-Star Pump for use with a 35# bucket. For professional use only. Part No.: Important Safety Instructions
More informationREMOTE COOLER AIR COOLED & WATER COOLED
REMOTE COOLER AIR COOLED & WATER COOLED Installation & User Instructions (To be left with the user) PLEASE READ CAREFULLY BEFORE INSTALLING THE UNIT Please follow these instructions carefully. Only if
More informationDISPENSING TROUBLESHOOTING INDEX
DISPENSING TROUBLESHOOTING INDEX 1. Irregular / Intermittent Dispensing from One Side 2. Dispensing won't stop when not holding the Dispensing Button 3. Steady Drip out of Faucet 4. Hot Water or Steam
More informationInstallation Instructions
Coupling Box Kit Cancels: IIK 340M-40-79 IIK 340M-40-88 9-05 Installation Instructions Part No. 320721-765, 330539-751, -752, -753, -754, -755, -756, and -757 NOTE: Read the entire instruction manual before
More informationPRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:
WARNING Read the instructions before using the machine PRESSURE WASHER MODEL NO: JETSTAR 1750 PART NO: 7333230 OPERATION & MAINTENANCE INSTRUCTIONS LS0711 INTRODUCTION Thank you for purchasing this CLARKE
More informationR100 Oil-Less Refrigerant Recovery Unit
R100 Oil-Less Refrigerant Recovery Unit Operation Manual 1 INTRODUCTION Welcome to simple, efficient refrigerant recovery with your new YELLOW JACKET Refrigerant Recovery Unit, R100. This unit combines
More informationCleaning the internal optics surfaces
Cleaning the internal optics surfaces The face of the fiber-optic assembly and the lens are directly exposed to sample fluids inside the analyzer s flow cell. Automatic rinse cycles use high-pressure rinse
More information