Dr. Weigert - New Standards in Cleaning and Disinfection of Medical Devices
|
|
- Eric Banks
- 5 years ago
- Views:
Transcription
1 Mongolian Symposium September 2016, Ulaanbaatar Dr. Weigert - New Standards in Cleaning and Disinfection of Medical Devices Michael Kacherai Chemische Fabrik Dr. Weigert Hamburg 1
2 Dr. Weigert Company Profile Dr. Walter Weigert Founder of the Chemical Factory in Hamburg in 1912 Until today an independent, familiy owned Corporation Bernd Ziege Managing Partner Dr. Weigert Company Profile 270 Employees in Germany and the eight Subsidiaries > 70 Mio. turnover, > 45 % overseas Mio Sales Trend Year
3 The Core Competence System Solutions for Cleaning and Disinfection in professional applications for mechanical, automated processes Company Site in Hamburg Research & Development Microbiology Application Technology Dosing / Control Technology Production, Logistics and Administration Competence, Flexibility and Customer Orientation 3
4 Competence in Medical and Laboratory Technology Experience for over 30 years Competence Reliability SK1 Dr. Weigert s System Solution Detergents and Disinfectants Dosing and Control Technology System Solution Attandance and Service 4
5 Slide 8 SK1 Puzzleteile auf Englisch Stefanie Kahl;
6 International Federation of Infection Control (IFIC): Cleaning: Cleaning is a process that removes foreign material (e.g. soil, organic material, micro-organisms) from an object. Disinfection: Disinfection is a process that reduces the number of pathogenic microorganisms, but not necessarily bacterial spores, from inanimate objects or skin, to a level which is not harmful to health. Sterilisation: Sterilisation is a process that destroys all microorganisms including bacterial spores. Sterilisation cannot be proved except by culturing, so normally an object is said to have been sterilised if it has gone through a controlled process of sterilisation. Effective factors of cleaning Time Mechanics Temperature Chemistry 5
7 Effective factors of cleaning Automatic cleaning Temperature Time Mechanics Chemistry Manual cleaning Temperature Time Chemistry Mechanics Effective factors of cleaning Mechanics wash arms, spray nozzles, channel adaption (rigid endoscopes), the right quantity of cleaning solution has to reach every spot on the goods to be washed Chemistry - Contamination varies in composition - Chemicals support the cleaning process by dissolving, emulsifying and dispersing the variety dirt - provides material protection to the instruments - Water quality influences the cleaning result and the materials Temperature best cleaning temperature, depending on the kind of dirt (denaturalisation of proteins) and kind of cleaner; parameters of disinfection Time important parameter, influencing the performance of cleaning and disinfection 6
8 7
9 Why automated reprocessing? staff of age than > 30 years Monday Tuesday Wednesday Thursday Friday staff of age than < 30 years Monday Tuesday Wednesday Thursday Friday Advantages of machine cleaning and disinfection Standardization Makes the work much easier Lower risks for personal (vapors of disinfectants, allergies, injuries) Lower risk of damaging instruments Lower risk of cross-contamination Documentation ti of fthe process parameters High reliability of the reprocessing Validation of automated process possible! 8
10 Contamination Proteins blood, tissue, liquor Fat lipids, lipoproteins, glycolipids, ointments (creams) Contamination from medical use Carbohydrates glycogen, glycoproteins, proteoglucane Organics X-ray contrast media, antiseptics Inorganics salts, disinfectants Ingredients of Detergents Caustic alkalinity (e.g. Sodium hydroxide) Silicates (e.g. Sodium silicate/ waterglass ) Phosphates h (Polyphosphates) h Phosphate substitutes (e.g. MGDA, NTA, EDTA, Polycarboxilates) Active Chlorine Active Oxygen Surfactants/ Emulsifiers Enzymes (e.g. protease, lipase,amylase) Phosphoric acid Citric acid Paraffin oil 9
11 Reprocessing of Medical Devices Automated Cleaning in Washer-Disinfectors with alkaline cleaners Guidelines recommending alkaline detergents: Robert-Koch-Institute (Germany): Alkaline cleaning is characterized by its high efficiency in dissolving up protein and fat residues as well as its antibiotic action. USA: CDC-Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008: Alkaline-based cleaning agents are used for processing medical devices because they efficiently dissolve protein and fat residues. Da Vinci-Endowrist-Instruments 10
12 Da Vinci- Endowrist-Instruments organic residues Properties of an alkaline, enzymatic cleaner with surfactants 3 different blood soils 6 differnet cleaners 0.5%, 5 min, 45 C, stirred dipping bath Meets national requirements regarding prion-prophylaxis, e.g. Robert Koch-Institute Germany: Alkaline cleaning Swiss-NOSO Switzerland: Cleaners with proteolytic enzymes Better Cleaning strength than ph-neutral enzymatic cleaners Combines advantages of alkaline and ph-neutral enzymatic cleaners 11
13 Cleaning efficacy: ph-neutral, enzymatic cleaner Cleaning efficacy: Alkaline, enzymatic cleaner with surfactant Material compatibility: Recommended by ISI for the cleaning of Endowrist/ DaVinci instruments And by endoscope manufacturer (e.g. Karl Storz, Fujifilm, Pentax) ph-value and cleaning result? There is no optimal ph-value for best cleaning results or blood removal! 12
14 Standard program sequence Dosing g of Cleaner Dosin ng of Rinse Aid Pre-Wash Cold Water 3-5 Min Cleaning DI-Water 55 C - 10 Min Intermedea te Rinse Softened or DI-Water cold - 1 Min Thermal Desinfection DI-Water 90-5 Min Drying C Dra ain Dra ain Dra ain Dra ain Standard program flow for cleaner, which do not require neutralization and second intermediate rinse! Standard program sequence Dosing g of Cleaner Do Neu osing of utralizer Dosin ng of Rinse Aid Pre-Wash Cold Water 3-5 Min Cleaning DI-Water 55 C - 10 Min Neutralization Softened or DI-Water cold - 1 Min Intermedia te Rinse Softened or DI-Water cold - 1 Min Thermal Disinfection DI-Water 90-5 Min Drying C Dra ain Dra ain Dra ain Dra ain Dra in Standard program sequence for cleaner, which require neutralization and second intermediate rinse! 13
15 Rinse aids for medical devices Useable for shorten the drying time in a mechanical cleaning program ph-neutral or slightly acidic Reduced surface tension of water Reduction of adherent moisture, less water drops Toxicological risk assessment in accordance with EN ISO (biological assessment of medical products) Completely biodegradable Recommended dosage: 0,3 3-1,0 ml/l to cold or heated final rinse water Shorter drying time of 30 to 70% Reduction of reprocessing time Lubricant for medical devices Useable for manual instrument care. Also available for instrument care in a mechanical cleaning program. ph-neutral. Reduces friction and abrasion in the joints of instruments. Toxicological risk assessment in accordance with EN ISO (biological assessment of medical products). Compatible with the intended steam and hot-air sterilization process. The sterility of sterile barrier systems during the storage time after using at the highest recommended concentration is not influenced. Each instrument has to be treated after each cleaning and disinfection process! 14
16 Friction corrosion Reason lack of instrument care Reprocessing of heat-sensitive flexible endoscopes Chemical disinfection with disinfectant based on Glutaraldehyde a) Standard disinfectants with 20% GDA b) With reduced odour based on special combination active substance 15
17 Reprocessing of heat-sensitive flexible endoscopes Chemical disinfection with disinfectant based on Peracetic Acid a) with and without additional component (e.g. regulator, activator) b) microbiocidal activity from C (bactericidal, fungicidal, mycobactericidal, virucidal, sporicidal) c) Good material compatibility (since 2002) d) energy-saving because of low application temperatures e) Environmentally friendly due to harmless decomposition products of peracetic acid Reprocessing of flexible endoscopes Cleaning step Disinfection step Intermediate rinse Final rinse Drying 16
18 Validation Critical processes, where the success could not be assessed by 100 %, should be validated. Cleaning and Disinfection Sealing Process Sterilization Automatic processes in washer-disinfectors can be validated. Daily Routine Checks Routine Checks of Technical Functions Successful execution of programme sequences, temperature, time, water pressure, dosage of process chemicals Routine Checks of Cleaning and Drying Performance each medical device which is removed from the WD should be visually inspected to ensure that it is clean and dry; if visual inspection is not possible, appropriate tests and testing intervals should be specified Routine Checks of Disinfection Performance not necessary to verify the disinfection performance with biological indicators, since the disinfectant action is assured by the effect of the water temperature for a defined period of time 17
19 Machine Mains water Softened water Water in the CSSD Deionised water (DI water) Process water from machines Steam Sterilizer Boiler feed water EN 285 (2009) Steam condensate EN 285 (2009) Water ingredients When heating the water Noncarbonate hardness (other Caand Mgsalts) other Solubles e.g. silicic acid Na-,K-salts Carbonate hardness (Ca-Hydrogen carbonate a.-carbonate, Mg-Hydrogen carbonate a. -Carbonate) Non-carbonate hardness remains in solution, but carbonate hardness leads to stubborn lime deposit. Total hardness = carbonate hardness + non-carbonate hardness 200 ppm CaCO3 = 150 ppm + 50 ppm 18
20 Constituents in tap water, which may cause problems in washer/ disinfectors Water hardness (Calcium, Magnesium): Scaling and deposits in machine and on contents Constituents in tap water, which may cause problems in washer/ disinfectors Heavy and non-ferrous metals (Iron, Manganese, Copper): Dark discolorations and deposits, inactivation of water softener 19
21 Constituents in tap water, which may cause problems in washer/ disinfectors Silicic acid/ silicates: Stubborn yellowish-brown or bluish-violet glaze-like deposits Constituents in tap water, which may cause problems in washer/ disinfectors Chlorides: Pinhole-like pitting corrosion on chrome steel 20
22 Chlorides: corrosion on chrome steel Constituents in tap water, which may cause problems in washing machines Evaporation residue 21
23 Optimal Water-Demineralisation Tap-water Softener Reverse-Osmose Ion-Exchange (1) or Conductivity Control Electrodeionisation Ion-Exchange (2) Deionized Water 22
24 Recommendations for Proper Maintenance of Instruments free: Thank you for your attention! 23
General Information on Application Technologies, Disinfection and Detergents in Automatic Reprocessing of Medical Devices
General Information on Application Technologies, Disinfection and Detergents in Automatic Reprocessing of Medical Devices Dr. Jürgen Staffeldt Chemische Fabrik Dr. Weigert Hamburg, Germany Decontamination
More informationINSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES
INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES Contents: Pagina 1 Introduction...2 2 Treatment instructions...2 3 Cleaning...2 3.1 Place of use...4
More informationGETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE VALIDATED
GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE Tested for optimal cleaning and performance ciso 15883 VALIDATED 2 GETINGE CLEAN GETINGE CLEAN THE ANSWER TO YOUR CLEANING PROBLEMS What does the word
More informationI.F.U Re/Processing Reusable Medical Devices
I.F.U Re/Processing Reusable Medical Devices Distributed by: MANUFACTURER: GA 26-09-001 -EN /20130719 Contents 1 Overview of preparation methods... 3 2 Safety and responsibility... 4 3 Explanation of symbols...
More informationSTERIS Instrument Cleaning Chemistries
STERIS is REACH Compliant. What is REACH? REACH is a European Union regulation concerning the Registration, Evaluation, Authorisation and restriction of Chemicals. It came into force on 1st June 2007 and
More informationThe Principles, The Process, and The Results:
The Principles, The Process, and The Results: Presented by: Fred Alston, CSPDT Eastern Region Clinical Sales and Support Manager April 21, 2017 I am an employee of Healthmark Industries Fraser, Michigan
More informationTHE BASICS OF DECONTAMINATION
THE BASICS OF DECONTAMINATION Objectives Review the basic factors that impact cleaning and decontamination of surgical devices Present the fundamentals of manual and automatic cleaning Review various cleaning
More informationINSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)
INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS) 1 INTRODUCTION This paper is intended to give general
More informationTHE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION
CFSA CSSD Conference Durban ICC Wednesday 8 th March 2017 Using technology to improve patient safety THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION Helen Loudon Independent Infection
More informationProcessing Instructions. Cleaning so easy.
EN Processing Instructions. Cleaning so easy. 2 A good decision. Congratulations on your new tiologic easyclean Wash-Tray. Machine treatment of the entire instrument set is an essential component of quality
More informationAS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/
s 65-201-00-65-202-00 01 Stopcock left 02 Spring Cap 03 Cannula CLEANING / STERILIZATION Immediately after use the instruments have to be soaked in a combined disinfection and cleaning solution in order
More informationAS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/
Arthroscopy irrigation cannula Arthroscopy irrigation cannulas 65-201-00-65-202-00 01 Stopcock left 02 Spring Cap 03 Cannula CLEANING / STERILIZATION Immediately after use the instruments have to be soaked
More informationProlystica Ultra Concentrate Instrument Cleaning Chemistries Now less is more. NEW generation instrument cleaners
Prolystica Ultra Concentrate Instrument Cleaning Chemistries Now less is more NEW generation instrument cleaners Now you can achieve a new level of automated cleaning Instrument Cleaning Chemistries Instruments
More informationTechnical Data Monograph. Reliance Vision Single Chamber Washer/Disinfector
Technical Data Monograph Reliance Vision Single Chamber Washer/Disinfector Table of Contents 1. Introducing: the Reliance Vision Single Chamber Washer/Disinfector...3 2. Environmentally Conscious Design...3
More informationWhy Clean? Sell more beer!
Contents 1. Why Clean? 2. What is Clean? 3. How to Clean 4. CIP Sequence 5. Detergents 6. Disinfectants 7. Hygienic Plant Design 8. Packaging 9. Chemical Safety 1. Why Clean? Why Clean? Remove food for
More informationAS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/
HIGH-FLOW Arthroscopy Sheath with one or two rotating Stopcocks HIGH-FLOW Arthroscopy Sheath with one or two rotating Stopcocks 65-227-01-65-240-12 1 Safety and responsibility Before using the instrument
More informationInstrument Cleaning Chemistries Automated Washing Process
Instrument Cleaning Chemistries Automated Washing Process Procedure Pre-cleaning Prolystica Enzymatic Presoak and Cleaner Klenzyme Enzymatic Presoak and Cleaner ZolvStat Multi-Enzymatic Detergent Pre-Klenz
More informationProcessing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG
Guide Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG Acceptance Cleaning, Disinfection Inspection, Packing Use T Sterilization t Storage Return
More informationTechnical Data Monograph. AMSCO 3052 Single-Chamber Washer/Disinfector AMSCO 5052 Single-Chamber Washer/Disinfector
Technical Data Monograph AMSCO 3052 Single-Chamber Washer/Disinfector AMSCO 5052 Single-Chamber Washer/Disinfector Table of Contents 1. The AMSCO 3052 Single-Chamber Washer/Disinfector and the AMSCO 5052
More informationINSTRUMENT REPROCESSING INSTRUMENTS MANUAL & AUTOMATED REPROCESSING OF INSTRUMENTS
INSTRUMENT REPROCESSING INSTRUMENTS MANUAL & AUTOMATED REPROCESSING OF INSTRUMENTS We care for patient and staff safety... and for your valuable instruments Reusable invasive medical devices must be reprocessed
More informationالمملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية
1. POLICY STATEMENT: Cleaning, decontamination and sterilization method should be done in CSSD service facility not in the end user department side. 2. PURPOSE: To ensure the proper way of collections,
More informationCleaning and Sterilisation for Burs, accessories and filling material
Cleaning and Sterilisation for Burs, accessories and filling material EN FOR DENTAL USE ONLY CLEANING AND STERILISATION PROCEDURE FOR BURS, ACCESSORIES AND FILLING MATERIAL 1) FOREWORD Devices that are
More informationREUSABLE ENDOSCOPY INSTRUMENTS (thermo resistant)
IMPORTANT ADVICES PLEASE READ CAREFULLY AND KEEP THE INSTRUCTIONS FOR FUTURE REFERENCE REUSABLE ENDOSCOPY INSTRUMENTS Field of application The following instructions are for all reusable endoscopy instruments
More informationSurgical Instrument Cleaning Process
Surgical Instrument Cleaning Process The Universal Processing Solution The Surgical Instrument Enzyme Detergent Lubricant Cleaners The Surgical Instrument Detergent Enzyme Lubricant Cleaner will cut costs.
More informationCleaning and Sterilization for Instruments & Posts
Cleaning and Sterilization for Instruments & Posts EN FOR DENTAL USE ONLY CLEANING AND STERILIZATION PROCEDURE FOR ENDODONTIC FILES, HAND INSTRUMENTS, PINS AND POSTS, STAINLESS STEEL DRILLS, STAINLESS
More informationPresenter: Malcolm McLaughlin Date: 04/04/2019. A Review of Medical Device and Optical Critical Cleaning
Presenter: Malcolm McLaughlin Date: 04/04/2019 A Review of Medical Device and Optical Critical Cleaning Introduction Malcolm McLaughlin VP, Product & Business Development 30+ years detergent formulation,
More informationSanosil disinfectants Use in CIP procedures
Sanosil disinfectants Use in CIP procedures Sanosil Norge AS, Brannfjellveien 86 A, 1181 Oslo Tlf.: +47-908 52 546 E-post: post@sanosil.no sanosil.no Des P034/en Use in CIP cleaning SANOSIL 1/8 Definition
More informationResidential Application
Residential Application Technical Data Sheet Matrix Polyacryl Network Appearance Small light yellow/beige balls Surface Ceramic Template Surface Moisture Content 24 to 28% Density 1,18 to 1,22 Weight 650g/L
More informationChristina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK
Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK Irrespective of where the decontamination is performed or who it is performed by the
More informationWhen you sterilize an instrument set, you know what the standards are.
Sterilization & Infection Control The importance of cleaning in earnest A regular column on sterilization and infection control issues. When you sterilize an instrument set, you know what the standards
More informationminietd2 the small reprocessor with the big performance.
Endoscope Reprocessing Automatic Endoscope Reprocessor the small reprocessor with the big performance. Covering all requirements in endoscope reprocessing. Hygienic safety for patients and medical staff
More informationCommercial dishwashing & cleaning agents
Commercial dishwashing & cleaning agents (Technical information sheet No. 05) Status: 20. April 2010 Published by: Arbeitsgemeinschaft Gewerbliches Geschirrspülen [Commercial Dishwashing Association] Feithstraße
More informationSOLUSCOPE SERIES 3 DESIGNED WITH THE FUTURE IN MIND FEATURES FLEXIBLE ENDOSCOPE DISINFECTOR / STERILISER
SOLUSCOPE SERIES 3 FLEXIBLE ENDOSCOPE DISINFECTOR / STERILISER FEATURES Sterile Cycle HLD Cycle Continuous Leak Test Channel Flow Monitoring Pre Disinfection Wash Cycle Fast Cycle Time Barcode Tracking
More informationCleaning Telemonitor & Accessories
Doc Active Date: 10/15/2012 Doc Review Date: 10/15/2013 Standard Operating Procedure (SOP) Cross Referencing: Honeywell acceptable cleaners/disinfectants; Honeywell return procedure for infected equipment;
More informationRECOMMENDATIONS FOR CLEANING DEVICES
RECOMMENDATIONS FOR CLEANING D E C O N TA M I N AT I O N A N D S T E R I L I Z AT I O N O F M E D A C T A I N T E R N A T I O N A L O R T H O P E D I C DEVICES 1 This document was prepared to provide cleaning,
More informationProcedures in University Laboratory. August 25, 2010 ULAR Continuing Education & Professional Development Class
Sanitization Common Sanitization Practices and Procedures in University Laboratory Animal Resources Justin Lahmers Justin Lahmers August 25, 2010 ULAR Continuing Education & Professional Development Class
More informationCLEANING INSTRUCTIONS
Reusable Instrument Care Manual Pagoda Pedicle Screw System Manufacturer Ortho Development Corporation 12187 South Business Park Drive Draper, UT 84020 Phone 801-553-9991 Fax 801-553-9993 www.orthodevelopment.com
More informationProcessing instructions for the Ligamys suture forceps
Processing instructions for the Ligamys suture forceps Table of contents 1 Scope of application 4 2 Warnings and precautions 4 5 3 Restrictions 6 4 Processing instructions 7 4.1 Processing immediately
More informationTechnical Data Monograph. The Instrument Protection Properties of Prolystica Enzymatic Presoak and Cleaner and other Enzymatic Products
Technical Data Monograph The Instrument Protection Properties of Prolystica Enzymatic Presoak and Cleaner and other Enzymatic Products Table of Contents ground...1 Purpose...1 Methods...1 Results...1 Conclusion...5
More informationWasher-Disinfectors - Effectiveness and Quality Assurance. T. Miorini Institute for Applied Hygiene / ÖGSV
Washer-Disinfectors - Effectiveness and Quality Assurance T. Miorini Institute for Applied Hygiene / ÖGSV Reprocessing of Medical Devices The reprocessing of reusable Medical Devices (MDs) which are to
More informationAS Medizintechnik GmbH Sattlerstraße Tuttlingen Germany
Important information You receive a high-quality product by purchasing this sterile container system. lts proper handling and use will be described in the following. Please read this user manual thoroughly
More informationAMSCO Washer/ Disinfectors. Central Sterile Services DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES. One Integrated Approach to Healthcare.
Central Sterile Services AMSCO Washer/ Disinfectors DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES One Integrated Approach to Healthcare. Understanding the intricacies of the CSSD process has allowed
More informationIntegra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions
Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing Instructions for Use. Description and Intended Use Integra LifeSciences Corporation reusable surgical device sets consist of various
More informationSUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY
SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY SUBJECT: ULTRASONIC CLEANER MONITORING DAILY DEPARTMENT: CPD, CSSD, SPA, MDRD, SPD, dental offices, medical offices and department using
More informationLab. Cleaning and Disinfection in Laboratories, Animal Housing and Industrial Cleaning. The Product Range
Lab Cleaning and Disinfection in Laboratories, Animal Housing and Industrial Cleaning The Product Range Our Experience for Your Safety Dr. Weigert has been a pioneer in automated cleaning of laboratory
More informationConsumer Decision Making Contest Study Guide Laundry Detergent
Consumer Decision Making Contest 2001-2002 Study Guide Laundry Detergent Perhaps you remember the song you sang as a child: This is the way we wash our clothes, we wash our clothes, we wash our clothes.
More informationRFP# FS REGION 8 TIPS FOOD PURCHASING CO-OP SANITATION AND CLEANING SUPPLIES FOR FOOD SERVICE AREA ONLY. Drop Ship 1 location 50 CT
REGION 8 TIPS FOOD PURCHASING CO-OP 2011-2012 SANITATION AND CLEANING SUPPLIES FOR FOOD SERVICE AREA ONLY PRODUCT DESCRIPTION BLEACH, CHLORINE: 5.25% SODIUM HYPOCHLORITE, INSTITUTIONAL PACK. LABEL TO CONTAIN
More informationDescaler & Prevention
Descaler & Prevention Treatment Method for existing scaled surfaces like inside of piping, tubes, Heaters, boilers, sump wall etc. By Deepak Chopra Watch Water GmbH Fahrlachstraße 14 68165 Mannheim Germany
More informationLaboratory Glassware Washer G 7883 CD
Operating and Installation Instructions Laboratory Glassware Washer G 7883 CD To prevent accidents en - US, CA and machine damage read these instructions before installation or use. M.-Nr. 07 779 610 2
More informationAccessories. Maybachstraße. Symmetry Fax: Revised 10/15
Recommended Care, Cleaning and Sterilization Instructions for Reusable Instruments & Accessories Symmetry Surgical Inc. 3034 Owen Drive, Antioch, TN 37013 USA 1-800-251-3000 Fax: 1-615-964-5566 www.symmetrysurgical.com
More informationCENTRAL STERILISATION. Innovative, hardworking Sterilisation & Infection Control products perfect for your Central Sterile Supply Department
CENTRAL STERILISATION Innovative, hardworking Sterilisation & Infection Control products perfect for your Central Sterile Supply Department DGM AND STERILISERS FROM 100 TO 1100 LITRES Made in Europe, DGM
More informationLaboratory Glassware Washer G 7883
Operating and Installation Instructions Laboratory Glassware Washer G 7883 To prevent accidents en - US, CA and machine damage read these instructions before installation or use. M.-Nr. 07 779 340 Contents
More informationManual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches
Caution Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches Do not use steel wool or abrasive cleaners. Avoid solutions containing iodine or with a high chlorine content.
More informationQUALITY SYSTEMS MANUAL. Plant Hygiene
Page: 1 of 5 PURPOSE: To ensure that the facility is maintained as to comply with all statutory regulations and to prevent contamination of the product and attraction of pests. RESPONSIBILITY: It is the
More information2015 Myco Industries, Inc Fax:
Endoscope Cleaning and Handling It is highly important that you manually clean the endoscope immediately after it is removed from the patient, BEFORE it is automated or manually disinfected. Cleaning your
More informationAesculap Implant Systems
Aesculap Implant Systems Aesculap Implant Systems Orthopedics USA Instructions for Use/Technical Description Page 1 of 14 Symbols on product packages Caution, general warning symbol Caution, see documentation
More informationEXCALIBUR SOFT-TEC - PRETREATMENT CHEMICAL REMOVAL SYSTEM AND WATER CONDITIONER SCALE CONTROL SYSTEMS
EXCALIBUR SOFT-TEC - PRETREATMENT CHEMICAL REMOVAL SYSTEM AND WATER CONDITIONER SCALE CONTROL SYSTEMS SOFT-TEC RESIDENTIAL WATER CONDITIONER PROCESS The Soft-Tec scale control system s reliability transforms
More informationTechnical Data Monograph. Prolystica HP Enzymatic Automated Detergent Instrument Protection Properties (North America)
Technical Data Monograph Prolystica HP Enzymatic Automated Detergent Instrument Protection Properties (North America) Table of Contents 1. Introduction....3 2. Purpose...3 3. Methods...4 4. Results....5
More informationPINNACLE MONITOR FOR AUTOMATED ENZYMATIC CLEANING (AEC) PROCESS
PINNACLE MONITOR FOR AUTOMATED ENZYMATIC CLEANING (AEC) PROCESS Instructions For Use Overview MKT 15-10AECIFU Rev 4/15 1 PURPOSE OF THE PINNACLE AEC TEST The test is to be used to monitor the effectiveness
More informationFlexible endoscope automated reprocessing system Safe and user friendly solutions for clinics
Flexible endoscope automated reprocessing system Safe and user friendly solutions for clinics Steelco E 1 Series Compact Automatic Endoscope Reprocessor Its compact design grants the highest level of flexibility
More informationTEMPLATE ASSISTED CRYSTALLIZATION. Presented By Ryan Lessing 11/13/2014
TEMPLATE ASSISTED CRYSTALLIZATION Presented By Ryan Lessing 11/13/2014 Different Forms of Hardness in Water Calcium and Magnesium Bicarbonate- This is what is referred to as temporary hardness. Once it
More informationSuction unit disinfection and cleaning with Dürr Dental
Suction unit disinfection and cleaning with Dürr Dental No more microbial contamination, clogging or encrustation Compressed air Suction Imaging Dental care Hygiene Dürr System Hygiene: the comfort of
More informationEVALUATION REPORT DISPOCLEAN ENDOSCOPE CLEANING BLADE. ALKAPHARM UK Ltd
EVALUATION REPORT DISPOCLEAN ENDOSCOPE CLEANING BLADE ALKAPHARM UK Ltd June 2008 HOSPITAL INFECTION RESEARCH LABORATORY CITY HOSPITAL DUDLEY ROAD BIRMINGHAM B18 7QH SUPPLIER/MANUFACTURER Alkapharm UK Ltd
More informationLAUNDRY GUIDE. Bedding. Textile solutions for a better guest experience
LAUNDRY GUIDE Bedding Textile solutions for a better guest experience Contents 1 Introduction 2 Detergent Selection 2 Washing 3 Bleach 4 Anti-chlor 4 Souring 4 Rinsing 5 Fluorescent Whitening Agents &
More informationInnovative Cleaning Technology
Selection Guide Innovative Cleaning Technology Spray Wash s Ultrasonic s Vibratory s Immersion s Acid s Floor s Maintenance s Machine Tool s Solvent s An ISO 9001:2008 COmpAny QualiChem 2003 Salem Industrial
More informationSKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS
SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS CAUTION: The following instructions are for all Sklar Coated stainless steel instruments. Read instructions prior to use. Improper
More informationUnderstanding the Balance
Understanding the Balance Soil is the foundation that builds strong crops, plants, roots and turf. Micro Biology in the soil is an absolute must in order to grow anything properly.. The Soil must contain
More informationPreserving the value of your suction unit. Systematic hygiene from Dürr Dental
Preserving the value of your suction unit. Systematic hygiene from Dürr Dental Systematic disinfection and cleaning of suction units COMPRESSED AIR SUCTION IMAGING DENTAL CARE HYGIENE Dürr System Hygiene
More informationLower Your Costs. Expand Your Flexibility.
W a s h i n g S y s t e m s Lower Your Costs. Expand Your Flexibility. Reliance Synergy Washer/Disinfector The Value of STERIS Synergy With the new Reliance Synergy Washer/Disinfector, STERIS introduces
More informationENDOSCOPE DECONTAMINATION : Where are we now!
ENDOSCOPE DECONTAMINATION : Where are we now! Christina Bradley Laboratory Manager Hospital Infection Research Laboratory City Hospital Dudley Road, Birmingham CHOICE OF DECONTAMINATION METHOD Depends
More informationBOILER SYSTEM CHEMICAL TREATMENT 101
BOILER SYSTEM CHEMICAL TREATMENT 101 The primary function of a boiler is to transfer heat from hot gases generated by the combustion of fuel into water until it becomes hot or turns to steam. The steam
More informationAMSCO Washer-Disinfectors. Central Sterile Services DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES. One Integrated Approach to Healthcare
Central Sterile Services DISCOVER POWERFUL WASHING AMSCO s WITH INCREASED EFFICIENCIES One Integrated Approach to Healthcare Understanding the intricacies of the CSSD process has allowed STERIS to deliver
More informationRecommendations for cleaning, decontamination and sterilisation. devices
Recommendations for cleaning, decontamination and sterilisation of MEDACTa INTERNATIONAL orthopedic devices 1 This document was prepared to provide cleaning, decontaminating and sterilising instructions
More informationAkiki Engineering Est.
Akiki Engineering Est. Water & Steam Experts 4.1. Closed System Catalogue October 7, 2010 Contents Chemical Products for Closed Systems......................... 3 Equipment For Closed Systems (1)...........................
More informationCase Study and 700 HP Steam Boilers - Scale
Case Study - 600 and 700 HP Steam Boilers - Scale Case study updated on June 10, 2013 Installer: MBI Water Solutions - HydroFLOW Master Distributor in the US Pacific Northwest. Customer: Chemical Plant
More informationCleaning & Sterilization
Handpieces & Attachments Instruments Cleaning & Sterilization System 7 System 6 System 5 CD4 CD3 SABO 2 SABO RemB CORE TPS Processing Instructions User/Patient Safety all contribute to the efficacy of
More informationLower Your Costs. Expand Your Flexibility.
Washing Systems Lower Your Costs. Expand Your Flexibility. Reliance Synergy Washer/Disinfector The Value of Synergy With the Reliance Synergy Washer/Disinfector, STERIS introduces washing systems technologies
More informationSustainability in commercial laundering processes. Module 2 Machine Technology. Chapter 1. Sinner s circle
Leonardo da Vinci Project Sustainability in commercial laundering processes Module 2 Machine Technology Chapter 1 Sinner s circle Module 2 Washing process Chapter 1 Sinner s circle 1 Content Sinner s circle
More informationCall our hotline at for all your instrument care and detergent questions. Medline Super Concentrates
Everybody Cares About Instrument Care Surgeons, O.R. staff and C.S. workers agree that proper instrument care makes sense. Besides prolonging the life of a costly investment, regular maintenance results
More informationPretreatment Processes for the Aluminum Extrusion Industry. Harry Adams - BCI Surface Technologies Bruce Chambeau Republic Chemical Co., Inc.
Pretreatment Processes for the Aluminum Extrusion Industry Harry Adams - BCI Surface Technologies Bruce Chambeau Republic Chemical Co., Inc. Purpose of Pretreatment Process Clean/etch, condition and treat
More informationINSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS
INSTRUCTIONS FOR USE & STERILIZATION PMS PRECISION MEDICAL SPECIALITIES GMBH Kreuzstrasse 5 DE-78532 Tuttlingen PO Box 4607 DE-78511 Tuttlingen Fon: +49 74 61 13 131 Fax: +49 74 61 76 698 info@pms-tuttlingen.de
More informationProfessional cleaning detergents
Electrolux Professional Customer Care Professional cleaning detergents Selection Guide Osteria Le Cementine, Roncade - Italy Electrolux Professional Customer Care Electrolux Genuine Chemicals The entire
More informationJames Law Chemicals Limited. Product List
James Law Chemicals Limited Product List Bleach Bleach 5% chlorine, thin bleach. The product disinfects and kills germs on most hard surfaces as we as eradicating malodours at source. Will also keep drains
More informationGlassware Washers: Cleaning Glassware and Implements Used in Compounding, Part 2. Abstract. Kate James, RPh Deborah Ruriani
Kate James, RPh Deborah Ruriani Glassware Washers: Cleaning Glassware and Implements Used in Compounding, Part 2 Abstract Compounding with glassware and utensils that are contaminated with drug residues
More informationFlexible endoscope automated reprocessing system
Flexible endoscope automated reprocessing system Safe, efficient and user friendly solutions for reprocessing flexible endoscopes in busy departments Driven by customer needs Steelco is a leading infection
More informationManual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files
Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files Cautions Do not use steel wool or abrasive cleaners. Avoid solutions containing iodine or with a high chlorine
More informationSunlight. Chlorophyll
Plant Nutrition & Soil Fertility Richard Smith Vegetable Crop and Weed Science Farm Advisor University of California Cooperative Extension Monterey, Santa Cruz and San Benito Counties Plant Nutrition 1.
More informationInnova new M2 and M3 series
Atherton Innova new M2 and M3 series The uncompromising Washer-Disinfectors Innova new M2 and M3 series Flexible equipment for economic results: modular washer/disinfectors R a n g e o f a p p l i c a
More informationSAFETY TECH. RRL Pendulum Test >36 (wet test) EN Class DS Bacterial resistance
SAFETY TECH Construction Length of roll Width Total Weight Wear layer thickness Total Height Compact Heterogeneous Approx 20lm 2m 2.4kg/m² 0.7mm 2.0mm Wear Classification EN ISO 10874 34/43 Abrasion Group
More informationSteelcoSure Independent performance verification of your equipment and processes
SteelcoSure Independent performance verification of your equipment and processes For the Environmentally conscious SteelcoSure Independent performance verification of your equipment and processes Irrespective
More informationHygiene within nursing homes, geriatric wards, rehabilitation centres automatic washer disinfectors
Hygiene within nursing homes, geriatric wards, rehabilitation centres automatic washer disinfectors Automatic washing and disinfection Contrary to domestic or industrial dishwashers, Steelco medical devices
More informationElaborating of a Reprocessing Instruction According to ISO Klaus Roth
Elaborating of a Reprocessing Instruction According to ISO 17664 Klaus Roth Operation, which have been cancelled due to not sufficient reprocessed instruments Year 2002 2003 2004 2005 Data of 57 hospitals**
More informationCLEANING AND HANDLING OF WRIGHT INSTRUMENTS
CLEANING AND HANDLING OF WRIGHT INSTRUMENTS 150824-0 The following languages are included in this packet: English (en) Deutsch (de) Nederlands (nl) Français (fr) Español (es) Italiano (it) Português (pt)
More informationBest Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices
Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices In BC Health Authorities THIS DOCUMENT IS INTENDED TO DESCRIBE BEST PRACTICES HEALTH
More informationOperating instructions Washer-disinfector G 7824
Operating instructions Washer-disinfector G 7824 To avoid the risk of accidents or damage to the machine, it is essential to read these instructions before it is installed and used for the first time.
More informationCLEANING AND SANITIZING
CLEANING AND SANITIZING Cleaning and sanitizing procedures must be part of the standard operating procedures that make up your food safety program. Improperly cleaned and sanitized surfaces allow harmful
More informationDisinfecting And Sanitizing Animal Facilities
Disinfecting And Sanitizing Animal Facilities Levels Of Sanitation Clean Remove soil Requires soap to remove oils May need a descaler (acid wash) Remove 99 % of bacteria Improve efficacy Sanitize Reduce
More informationClass 3: Soil Sampling and Testing. Chris Thoreau
Class 3: Soil Sampling and Testing Chris Thoreau What is Soil Testing? What are We Testing For? Soil Sampling Methodologies Soil Testing Interpreting Soil Test Results What is Soil Testing? Soil testing
More informationDescription. Main components. Lifting eyes To used for lifting and transport securing. Carrying bar Carries the cassettes and the pressure plate.
Description English Description Main components Lifting eyes To used for lifting and transport securing Frame plate Carrying bar Carries the cassettes and the pressure plate. Support column Connections
More informationGuidelines for Cleaning, Disinfecting and Sterilizing Medela Healthcare Products REPROCESSING GUIDE. Precious life Progressive care
Guidelines for Cleaning, Disinfecting and Sterilizing Medela Healthcare Products REPROCESSING GUIDE Precious life Progressive care Contents Reprocessing Guide (Cleaning/ Disinfection / Sterilization)...
More information