1 Installation Manual F N62X and N62XXX models: F N64X and N64XXX models: F N64XIM and N64XIMXX models: F N82X and N82XXX models: F N84X and N84XXX models: F N84XIM and N84XIMXX models: 6 cu.ft., 2way, R.V. refrigerats. 6 cu.ft., 2way 3way, R.V. refrigerats. 6 cu.ft., 2 way, R.V. refrigerats with ice maker. 8 cu.ft., 2way, R.V. refrigerats. 8 cu.ft., 2way 3way, R.V. refrigerats. 8 cu.ft., 2way, R.V. refrigerats with ice maker. The model numbers of 3way refrigerats include.3. The model numbers of 2way refrigerats do not. WARNING: Improper installation, adjustment, alteration, service maintenance can cause injury property damage. Refer to th manual. F asstance additional infmation, contact a qualified installer, service agency, gas supplier. FOR YOUR SAFETY Do not ste use gasoline flammable vaps and liquid in vicinity of th any appliance. FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. Don t touch electrical switches. 3. Extinguh any open flame. 4. Immediately call your gas supplier. WARNING: DO NOT install th refrigerat in below deck marine applications. Do not install th refrigerat in a fixed indo cabin dwelling applications. Th refrigerat must use only NORCOLD designed and approved outside air intake and exhaust ventilation f crect and safe operation. Any ventilation could cause lethal combustion exhaust fumes and/ explosive propane gas fumes to be in living area and/ to be below deck. Englh French NORCOLD, Inc. P.O. Box 4248 Sidney, OH Part No J (703)

2 Table of Contents Safety Instructions Safety Awareness... 2 Safety Instructions... 2 Certification and Code Requirements... 3 Ventilation Requirements... 3 Assemble Enclosure f Refrigerat... 4 Install Lower and Upper Vents... 4 Install Decative Do panels (nonmetal do models)... 6 Install Refrigerat... 6 Reverse Do Swing (optional)... 7 Connect Ice Maker (N64XIM, N64XIMXX, N84XIM, and N84XIMXX models)... 8 Connect water supply line... 8 Connect Electrical Components... 8 Connect 120 volts AC supply... 8 Connect 12 volts DC supply... 9 Connect Propane Gas Components... 9 Connect propane gas supply system... 9 Examine gas supply system f leaks Ignition and Start Up Ignition and start up (N64X, N64XXX, N64XIM, N64XIMXX, N84X, N84XXX, N84XIM, and N84XIMXX models) Ignition and start up (N62X, N62XX, N82X, and N82XX models) Do a test of gas safety valve Shut downall models Fault Codes (N62X, N62XX, N82X, and N82XX models) Fault Codes (N64X, N64XXX, N64XIM, N64XIMXX, N84X, N84XXX, N84XIM, and N84XIMXX models) Safety Awareness Read th manual carefully and understand contents befe you install refrigerat. Be aware of possible safety hazards when you see safety alert symbol on refrigerat and in th manual. A signal wd follows safety alert symbol and identifies danger of hazard. Carefully read descriptions of se signal wds to fully know ir meanings. They are f your safety. WARNING: Th signal wd means a hazard, which if igned, can cause dangerous personal injury, death, much property damage. CAUTION: Th signal wd means a hazard, which if igned, can cause small personal injury much property damage. WARNING: Th refrigerat not approved f use as a free standing refrigerat. It equipped f use of propane gas only and can not be changed to use any fuels (natural gas, butane, etc.). Increct installation, adjustment, alteration, maintenance of th refrigerat can cause personal injury, property damage, both. Obey instructions in th manual to install intake and exhaust vents. Do not install refrigerat directly on carpet. Put refrigerat on a metal wood panel that extends full width and depth of refrigerat. Propane gas can ignite and cause an explosion that can result in property damage, personal injury, death. Do not smoke create sparks. Do not use an open flame to examine propane gas supply line f leaks. Always use two wrenches to tighten loosen propane gas supply line connections. Make sure electrical installation obeys all applicable codes. Certification and Code Requirements section. Do not bypass change refrigerat s electrical components features. Do not spray liquids near electrical outlets, connections, refrigerat components. Many liquids are electrically conductive and can cause a shock hazard, electrical shts, and in some cases fire. The refrigerat cooling system under pressure. Do not try to repair to recharge a defective cooling system. The cooling system contains sodium chromate. The breathing of certain chromium compounds can cause cancer. The cooling system contents can cause severe skin and eye burns, and can ignite and burn with an intense flame. Do not bend, drop, weld, move, drill, puncture, hit cooling system. CAUTION: The rear of refrigerat has sharp edges and cners. To prevent cuts abrasions when wking on refrigerat, use caution and wear cut restant gloves. Installation Manual 2

3 Certification and Code Requirements Ventilation Requirements WARNING: The completed installation must: Make sure re sufficient intake of fresh air f combustion. Make sure living space completely olated from combustion system of refrigerat. Th refrigerat certified by CSA International as meeting latest edition of ANSI Z21.19 / CAN 1.4 standards f installation in mobile homes recreational vehicles. The installation must obey se standards and th Installation Manual f NORCOLD limited warranty to be in effect. Installation must confm with following as applicable: In United States and Canada: Local codes, in absence of local codes, National Fuel Gas Code, ANSI Z223.1/NFPA 54, Natural Gas and Propane installation Code, CSA B149.1, ANSI A119.2 Recreational Vehicles Code, and CSA Z240 RV Series, Recreational Vehicles. A manufactured home (mobile home) installation must confm with Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [fmerly Federal Standard f Mobile Home Construction and Safety, Title 24 (part 280), and current CSA Z240.4, Gasequipped Recreational Vehicles and Mobile Housing. If an external power source utilized, appliance, when installed, must be electrically grounded in accdance with local codes, in absence of local codes, National Electrical code, and ANSI/NFPA 70, Canadian Electrical Code, CSA C22.2. Parts 1 and 2. All propane gas supply piping and fittings must obey local, state, and national codes about type and size. These components must also obey current NFPA 501C section 2 4, and in Canada with current CAN Standard. Make sure re complete and unrestricted ventilation of flue exhaust which, in gas mode, can produce carbon monoxide. The breathing of carbon monoxide fumes can cause dizziness, nausea, in extreme cases, death. Make sure refrigerat completely olated from its heat generating components through crect use of baffles and panel construction. Certified installation needs one lower intake vent and one upper exhaust vent. Install vents exactly as written in th manual. Any installation method voids both certification and facty warranty of refrigerat. The bottom of opening f lower intake vent, which also service access do, must be even with immediately below flo level. Th allows any leaking propane gas to escape to outside and not to collect at flo level. CSA International certification allows refrigerat to have zero (0) inch minimum clearance at sides, rear, top, and bottom. While re are no maximum clearances specified f certification, following maximum clearances are necessary f crect refrigerat perfmance: Bottom 0 inch min. 0 inch max. Each Side 0 inch min 1/2 inch max. Top 0 inch min. 1/4 inch max. Rear 0 inch min. 1 inch max. These clearances plus lower and upper vents cause natural air draft that necessary f good refrigeration. Cooler air comes in through lower vent, goes up around refrigerat coils where it removes excess heat from refrigerat components, and goes out through upper vent. If th air flow blocked decreased, refrigerat will not cool crectly. Each NORCOLD model certified by CSA International f crect ventilation. Install only certified vents that are lted in th manual. Installation Manual 3

4 Assemble Enclosure f Refrigerat 1. Make sure enclosure inches high f N82X, N82XXX, N84X, N84XXX, N84XIM, and N84XIMXX models inches high f N62X, N62XXX, N64X, N64XXX, N64XIM, and N64XIMXX models x inches wide x inches deep. 2. Make sure flo solid and level. The flo must be metal a wood panel and extend full width and depth of enclosure. The flo must be able to suppt weight of refrigerat and its contents. 3. Make sure re are no adjacent heat sources such as a furnace vent, a hot water heater vent, etc. Install Lower and Upper Vents 1. Using following chart, decide which vents and rough opening (RO) sizes to use: Certified Vent P/N RO Height RO Width Upper Roof N/A N/A Exhaust Cap Upper Roof in. 5 1/4 in. Exhaust Vent Upper Exhaust /4 in. 21 1/2 in. & Lower Intake Plastic Lower Square /4 in. 19 3/8 in. Cner Intake 2. Install lower intake vent ( Art01598, Art01599, and Art01602): NOTE: The lower intake vent also service access opening f components on rear of refrigerat. WARNING: Make sure bottom of opening of lower intake vent even with immediately below flo level. Th allows any leaking propane gas to escape to outside and not to collect at flo level. Make sure bottom of opening of lower intake vent [1] even with immediately below flo level. 3. Install upper exhaust vent: CAUTION: Make sure that no sawdust, insulation, construction debr on refrigerat in enclosure. Debr can cause a combustion hazard and prevent refrigerat from operating crectly. NOTE: Tighten screws of upper roof exhaust cap to 10 inchpounds max. Also make sure that air flow around upper roof exhaust cap not blocked decreased by roof mounted features such as a luggage carrier, an air conditioner, a solar panel, etc. If design of vehicle allows, install roof exhaust vent [4] directly above condenser [3] of refrigerat ( Art01598): Install a baffle [5] to prevent stagnant hot air in area [6] above refrigerat. Make sure re less than 1/4 inch clearance [7] between baffle and top of refrigerat. Make sure baffle full width of inside of enclosure. If design of vehicle does not allow you to install roof exhaust vent directly above condenser [3] of refrigerat ( Art01599): Align roof exhaust vent [4] above condenser [3] of refrigerat and move it inboard as necessary. Install two baffles [8] to prevent stagnant hot air in area [6] above refrigerat. Make sure baffles are full width of inside of enclosure. Make sure that baffles are no me than 45 from vertical [9]. Put one baffle between top rear edge of refrigerat and inside edge of upper exhaust vent opening. Put baffle between outside edge of upper exhaust vent opening and side wall of vehicle. If depth of enclosure 24 inches me and less than 25 inches, no baffles are necessary at rear of enclosure. If depth of enclosure 25 inches me and less than 26 inches, add two baffles [10] to rear of enclosure ( Art01598 and Art01599). Align lower intake vent vertically below coils [2] and condenser [3] of refrigerat. Installation Manual 4

5 Put one baffle 18 inches to 18 1/2 inches above bottom of enclosure [26] (4 1/4 inches to 4 3/4 inches above top of lower intake vent opening REF) [27]. Put baffle at lowest edge of condenser [3] of refrigerat. Make sure that baffles are 1 inch less [28] from coils [2] and condenser of refrigerat. Make sure that baffles are full width of inside of enclosure. If depth of enclosure me than 26 inches, install a wood an aluminum galvanized sheet solid box baffle [25] in rear of enclosure ( Art01617 and Art01618). Make sure that bottom of solid box baffle 18 inches to 18 1/2 inches above bottom of enclosure [26] (4 1/4 inches to 4 3/4 inches above top of lower intake vent opening REF) [27]. Make sure that back of solid box baffle perpendicular to bottom of enclosure. Make sure that back of solid box baffle eir against top of enclosure against angled baffle [8] (depending on vehicle design). Make sure that solid box baffle one inch less [28] from coils [2] and condenser of refrigerat. Make sure that solid box baffle full width of inside of enclosure. If re me than 1/2 inch of clearance between eir side of refrigerat and wall, fill space with fiberglass insulation add a baffle to eliminate excess clearance. If design of vehicle does not allow you to install a roof exhaust vent, install an upper sidewall exhaust vent. NOTE: The refrigerat 23.7 in. min. to 24.0 in. max. from rear of breaker to rear of condenser [11]. N62X, N62XXX, N64X, N64XXX, N64XIM, and N64XIMXX models are 48.7 in. min. to 49.0 in. max. from bottom of refrigerat to bottom of refrigerat condenser [12]. CAUTION: Only use an upper sidewall exhaust vent on refrigerat models that are equipped with a fan. If you use an upper sidewall exhaust vent on a refrigerat model that not equipped with a fan, refrigerat cooling perfmance will be po. Make sure refrigerat model equipped with a fan. Install upper sidewall exhaust vent [13] ( Art01592 and Art01593). F N62X, N62XXX, N64X, N64XXX, N64XIM, and N64XIMXX models, make sure dtance [14] from bottom of enclosure to top of rough opening f upper exhaust vent at least 55 inches. F N82X, N82XXX, N84X, N84XXX, N84XIM, and N84XIMXX models, make sure dtance [14] from bottom of enclosure to top of rough opening f upper exhaust vent at least 62 inches. Align upper exhaust vent [13] hizontally above lower intake vent [1] of refrigerat. To prevent stagnant hot air in area above refrigerat, install an aluminum galvanized steel sheet baffle [15] between top of refrigerat and top of upper exhaust vent. Make sure re less than 1/4 inch clearance between baffle and top of refrigerat and that baffle overlaps refrigerat 1 inch less [16]. Make sure that baffle against wall of vehicle at top of upper exhaust vent and 1/4 inch less from top of opening f upper exhaust vent [17]. Make sure baffle full width of inside of enclosure Make sure clearance at sides of refrigerat crect: If re me than 1/2 inch of clearance between eir side of refrigerat and wall, fill space with fiberglass insulation add a baffle to eliminate excess clearance. N82X, N82XXX, N84X, N84XXX, N84XIM, and N84XIMXX models are 55.7 in. min. to 56.0 in. max. from bottom of refrigerat to bottom of refrigerat condenser [12] ( Art01601). Installation Manual 5

6 When using an upper sidewall exhaust vent: If depth of enclosure me than 24 inches and less than 26 inches [18], install a bent aluminum galvanized steel sheet baffle [19] to rear of enclosure ( Art01592). Make sure that bend of baffle full width of inside of enclosure. Make sure that bend of baffle flush with bottom edge of upper intake vent do frame. Make sure that top edge of baffle 1/4 inch less [20] below condenser [3] and that re 1/4 inch less clearance [21] between lower rear cner of condenser and baffle. If depth of enclosure me than 26 inches [22], install a wood an aluminum galvanized steel sheet solid box baffle [23] between lower intake vent and upper exhaust vent ( Art01593). Make sure that solid box baffle full width of inside of enclosure. Make sure that bottom of solid box baffle 18 inches to 18 1/2 inches above bottom of enclosure [26] (4 1/4 inches to 4 3/4 inches above top of lower intake vent opening REF) [27]. Make sure that back of solid box baffle perpendicular to bottom of enclosure. Make sure that hizontal top of solid box baffle even with bottom edge of upper exhaust vent [13]. Make sure that vertical top edge of baffle 1/4 inch less [20] below lower rear cner of condenser [3]. Make sure that re 1/4 inch less clearance [21] between rear of condenser and baffle. Install Decative Do Panels (nonmetal do models) NOTE: The dos are made to accept decative panels. The decative panels must be 3/16 inch less in thickness. Install decative do panels in refrigerat dos befe installing refrigerat in vehicle. Make an upper do panel that 21 19/32 inches wide x 14 17/32 inches high. Make a lower do panel that : 21 19/32 inches wide and 31 5/8 inches high (f N62X, N64X, and N64XIM models) 38 5/8 inches high (f N82X, N84X, and N84XIM models). Pull panel retainer [1] off each do ( Art00965). Push decative do panel [2] into slots of do [3]. Push each panel retainer into slot on edge of do. Install Refrigerat Put refrigerat in position ( Art00962, Art00963, and Art00964): WARNING: Make sure combustion seal [11] not broken, completely around refrigerat mounting flanges, and between mounting flanges and wall of enclosure If seal not complete, exhaust fumes can be present in living area of vehicle. The breathing of exhaust fumes can cause dizziness, nausea, in extreme cases, death. Push refrigerat completely into enclosure. Put upper trim piece [13] onto front of refrigerat. Put screws [12] through upper and lower mounting flanges on front of refrigerat and into enclosure wall and flo. Put a cap [14] on each of screw holes in upper trim piece [13] on front of refrigerat. WARNING: Do not omit bottom trim piece. Th piece part of combustion seal. Installation Manual 6

7 Push bottom trim piece [15] onto front of refrigerat. Put two screws [16] through trim piece, mounting flange, and into flo. Put screws through mounting flange on rear of refrigerat and into flo. Reverse Do Swing (optional) Th refrigerat has do hinges that allow you to change direction do opens by moving hinges on a diagonal to opposite side. 1. Remove dos ( Art00986): Remove stage bins from dos. Remove and save both hinge pins [1] from each do. Pull do latch and remove each do away from refrigerat. 2. Change position of cabinet hinges and strike plate ( Art00987): Remove and save screws from strike plate [2a]. Remove two plastic hole caps that are near strike plate. Remove Lshaped plastic covers that are opposite hinges. Remove and save screws from upper cabinet hinge [3a] of each do. Put each of se hinges on side of refrigerat as lower hinge [3b]. Attach each of se hinges with screws. Remove and save screws from lower cabinet hinge [4a] of each do. Put each of se hinges on side of refrigerat as upper hinge [4b]. Attach each of se hinges with screws. Put Lshaped plastic covers over holes that were used by hinge screws. Remove and save screw from front box [6]. Pull front box away from refrigerat and out from under controls [7] ( Art00983). Reverse front box and put it on opposite side of controls. Attach front box to refrigerat with screw. Put strike plate on opposite side of refrigerat [2b]. Put two round plastic caps into holes that are near strike plate. Put plastic caps [8] into holes that were used by front box. 3. Change position of do handles and do hinges ( Art00984 and Art00985): Remove plastic cap that opposite upper hinge of upper do. Remove screws [9] from do handle [10] and do hinge [11]. Remove round head screw [12] and do handle from each do. Remove upper hinge of each do. Put each of se hinges on side of do as lower hinge. Attach each of se hinges with screws that were removed from side. The recommended tque f each cap screw 35 in. lbs. Remove lower hinge of each do. Put each of se hinges on side of do as upper hinge. Attach each of se hinges with screws that were removed from side. Reverse each do handle and put lower do handle on upper do and upper do handle on lower do. Attach each do handle with a cap screw and a round head screw. Put plastic cap into hole that opposite upper hinge of upper do. 4. Reinstall dos ( Art00986): Make sure each hinge bushing [13] in crect position. Installation Manual 7

8 Put each hinge bushing into bottom side of each do hinge. Put each do in position on refrigerat. NOTE: To prevent damage to threads of hinge pins, turn hinge pins by hand until tight and n tighten with a screwdriver. CAUTION: Apply Loctite removable thread locker (blue) to threads of hinge screws befe assembly to prevent loosening during use. Do not allow Loctite to contact any of plastic surfaces of refrigerat because it can damage those surfaces. Align hinges and put hinge pins into each do. Tighten hinge pins. Put stage bins in dos. F copper tubing, use brass sleeve. F plastic tubing, use plastic sleeve [2]. F plastic tubing with.040 in. wall thickness, also use brass insert [3]. Flush water supply line until water clear. Put tubing into adapter [5] until it against stop of adapter. Tighten compression nut by hand (hard finger tight). Using two wrenches, tighten compression nut 1 ½ to 2 turns. Open water shut off valve of vehicle. Examine connections f leaks. Connect Ice Maker (N64XIM, N64XIMXX, N84XIM, and N84XIMXX models) The ice maker assembled to refrigerats at facty as optional equipment. If refrigerat does not have a facty installed ice maker, one can not be added to refrigerat at a later time. The refrigerat installer must connect a cold water supply line to solenoid valve at rear of refrigerat. The following are necessary to connect icemaker: 1/4 in. OD copper tubing f water supply line. OR 1/4 in. OD plastic tubing f water supply line. 1/4 in. shut off valve in water supply line. Th should be easily accessible through lower intake vent. Connect water supply line: Install a 1/4 in. OD water supply line [1] from water shut off valve of vehicle to solenoid water valve [2] at rear of refrigerat ( Art01014): NOTE: A brass compression nut [1], a brass sleeve, a plastic sleeve [2], and a brass insert [3] are supplied and attached to rear of refrigerat ( Art01604). Put compression nut and n sleeve onto water supply line [4]. Connect Electrical Components AC Operation DC Operation 120 volts AC voltage (132 volts max. 108 volts min.) 12 volts DC control voltage (15.4 volts max volts min.) 12 volts DC control voltage (15.4 volts max volts min.) Th refrigerat operates on se electrical sources. Operation out of se limits may damage refrigerat s electrical circuit parts and will void warranty. WARNING: The rear of refrigerat cooling system has hot surfaces and sharp surfaces that can damage electrical wiring. Make sure that re a good clearance between all electrical wiring and cooling system of refrigerat. Position any electrical wiring within refrigerat enclosure opposite burner side of refrigerat. Do not put any electrical wiring through roof exhaust vent. Failure to crectly position electrical wiring can result in electrical shock fire. Connect 120 volts AC supply: WARNING: Connect AC power cd(s) only to a grounded threeprong receptacle. Do not remove round ground prong from any of AC power cds. Do not use a two prong adapter an extension cd with any of AC power cds. Operation of refrigerat without crect ground can cause dangerous electrical shock death if you are touching metal parts of refrigerat. Installation Manual 8

9 Put AC power cd(s) into a grounded threeprong receptacle: Make sure receptacle positioned within easy reach of lower intake vent. Make sure power cd(s) does not touch burner cover, flue pipe, any hot component that could damage insulation of power cd. Connect 12 volts DC supply: As dtance from vehicle battery to refrigerat increases, crect AWG wire size and fuse size also increases. If wire size too small f dtance, a voltage drop occurs. The voltage drop decreases output of system heater and causes po cooling perfmance. 1. Determine min. wire size and max. fuse size to use: WARNING: If you use an increct wire size and/ fuse size, electrical fire can result. On 2way models, use a minimum of 18 AWG wire and a maximum 6 Amp fuse. On 3way models, measure dtance from vehicle battery to refrigerat. If dtance 0 20 feet, use a minimum of 10 AWG wire and a maximum 30 Amp fuse. If dtance over 20 feet, use a minimum of 8 AWG wire and a maximum 40 Amp fuse. If wire size larger than min. size, use crect fuse per RVIA A119.2 standard local codes. 2. Install a fuse in DC power supply wires between battery and refrigerat: Put fuse as close to battery as possible. 3. Connect DC power supply wires ( Art00966): Attach a 1/4 inch Quick Connect terminal to each DC power supply wire. NOTE: Do not use chass of refrigerat vehicle frame as one of conducts. Attach DC power supply wires only to battery and power board [1] of refrigerat. Push positive DC power wire onto power board terminal that marked 12VDC. Push DC ground wire onto power board terminal that marked 12V GND1. Make sure each DC power supply wire on crect polarity terminal. Connect Propane Gas Components Th refrigerat operates on propane gas at a pressure of 11 inches Water Column Propane. The controls operate on 12 volts DC (10.5 volts min volts max.). Operation out of se limits can damage refrigerat electrical circuit parts and will void warranty. Connect propane gas supply system: WARNING: Be very careful when wking on near propane gas system. Do not smoke, use an open flame near propane gas system. Do not use an open flame to examine f leaks. Do not connect refrigerat to propane gas tank without a pressure regulat between m. To avoid a propane gas leak, always use two wrenches to tighten loosen propane gas supply line connections. Leaking propane gas leak can ignite explode and result in dangerous personal injury death. Connect gas supply line to refrigerat: Make sure that all tubing and fittings obey all local, state, and national codes about size and type. Make sure that all flexible metal connects obey current CAN16.10 Standard. Make sure that materials used f gas supply line obey both current ANSI A (NFPA 1192) and CSA Z240 Standards on Recreational Vehicles. Ncold recommends use of 3/8 inch copper tubing as gas supply line and requires a 3/8 inch SAE (UNF 5/818) male flare fitting as connection to refrigerat. Put propane gas supply line up through flo of enclosure. Make sure hole through flo large enough allow clearance f gas supply line. Put a wear restant seal (grommet, sealant, etc.) around gas supply line where it goes through flo to prevent vibration and abrasion. To prevent vibration and abrasion, make sure that gas supply line not against anything in enclosure. Attach gas supply line to bulkhead fitting of refrigerat. Installation Manual 9

10 Examine gas supply system f leaks: WARNING: Do not allow leak detecting solution to touch electrical components. Many liquids are electrically conductive and can cause electrical shts and in some cases, fire. Use a leak detecting solution to examine gas supply line and all propane gas connections f leaks. If you use compressed air f test: The pressure of compressed air at manual shut off valve of refrigerat must not be me than 1/2 psig (14 inches Water Column). If pressure of compressed air me than 1/2 psig (14 inches Water Column), remove gas supply line from bulkhead fitting of refrigerat befe test. If pressure of compressed air equal to less than 1/2 psig (14 inches Water Column), close manual shut off valve of refrigerat befe test. Ignition and Start Up Befe ignition start up of refrigerat: Make sure air flow in lower intake vent, through refrigerat coils and condenser, and out upper exhaust vent not blocked decreased. Make sure re are no combustible materials in around refrigerat. Ignition and start up: (N64X, N64XXX, N64XIM, N64XIMXX, N84X, N84XXX, N84XIM, and N84XIMXX models) ( Art01018) NOTE: If gas does not ignite in 30 seconds, gas safety valve of refrigerat automatically closes and controls eir select a different energy source and no FL appears in center dplay controls change to Stand By Mode. In Stand By Mode, an audible alarm starts and code no FL appears in center dplay. Th means that gas did not ignite. If gas does not ignite after several attempts, refer to Fault Codes section of th manual. Automatic Mode Operation: 1. Push ON/OFF button [1] to start refrigerat. 2. Push MODE button [2] until AU appears in center dplay [4]. 3. Push TEMP SET button [3] as needed to set rmostat at 46 temperature setting. If AU AC appears in center dplay, it means that: 120 volt AC power available to refrigerat. The refrigerat operating on AC electric power. After ten seconds, AU AC goes off and only a green dot. remains to show that refrigerat operating. If AU LP appears in center dplay, it means that: 120 volt AC power not available to refrigerat. The refrigerat operating on propane gas. After ten seconds, AU LP goes off and only a green dot. remains to show that refrigerat operating. On threeway models only, if AU dc appears in center dplay, it means that: 120 volt AC power and propane gas are not available to refrigerat. The refrigerat operating on DC power. After ten seconds, AU dc goes off and only a green dot. remains to show that refrigerat operating. Manual Mode Operation: 1. Push ON/OFF button [1] to start refrigerat. 2. Push MODE button [2] until LP shows in center dplay [4]. 3. Push TEMP SET button [3] to set rmostat at 46 temperature setting. 4. The LP remains until you select a different operating mode shut down refrigerat. Ignition and start up: (N62X, N62XX, N82X, and N82XXX models) ( Art01019) NOTE: If gas does not ignite in 30 seconds, gas safety valve of refrigerat automatically closes and controls eir select a different energy source and F appears in center dplay controls change to Stand By Mode. Installation Manual 10

11 In Stand By Mode, code F appears in center dplay. Th means that gas did not ignite. If gas does not ignite after several attempts, refer to Fault Codes section of th manual. Automatic Mode Operation: 1. Push ON/OFF button [1] to start refrigerat. 2. Push TEMP SET button [2] as needed to set rmostat at 46 temperature setting. If AUTO bar [3] and AC bar [4] appear in center dplay [5], it means that: 120 volt AC power available to refrigerat. The refrigerat operating on AC electric power. If AUTO bar and LP GAS bar [6] appear in center dplay, it means that: 120 volt AC power not available to refrigerat. The refrigerat operating on propane gas. Manual Mode Operation: 1. Push ON/OFF button [1] to start refrigerat. 2. Push MODE button [8] until AUTO bar goes off and only LP GAS bar remains. 3. Push TEMP SET button [2] as needed, to set rmostat at 46 temperature setting. 4. The LP GAS bar remains until you select a different operating mode shut down refrigerat. Do a test of gas safety valve: 1. Start up refrigerat in manual mode operation. 2. Open lower intake vent. 3. Remove one wire from solenoid of gas safety valve at rear of refrigerat. 4. Within 30 seconds, flame should extinguh. Th means that gas safety valve operating crectly. 5. Put wire back on solenoid of gas safety valve. 6. Close lower intake vent. Shut down all models: To shut down refrigerat, push and hold ON/OFF button f two seconds. Installation Manual 11

12 Installation Manual 12 Fault Codes (N62X, N62XXX, N82X, and N82XXX models) Codes ault F g Meanin Code ault F s Action Crective No dplay. DC voltage to unavailable control refrigerat panel OFF. refigerat ON. refrigerat operational. vehicle of equipment battery charging applicable). (if operational AC/DC converter Service Ncold authized dealer your "d" open f was do The minutes. than 2 me do. Close "F" not did burner The reignite. ignite open. tank(s) gas propane of valve pressure. crect at gas propane open. refrigerat of valve off shut manual air "Removing supply line. gas propane in air no re manual. th section of supply lines" gas propane from Service Ncold authized dealer your "A" AC voltage to unavailable control. refrigerat outlet. serviceable a into plugged refrigerat intact. vehicle of breaker circuit fuse applicable). (if operational generat vehicle Service Ncold authized dealer your "C" to DC voltage control refrigerat low. too panel operational. vehicle of equipment battery charging applicable). (if operational AC/DC converter Service Ncold authized dealer your "n" cooling refrigerat The cooling. stopped has unit reset Befe time 1st blocked. not are vents do(s). Close open. not do(s) a level. vehicle reset After time 2nd Service Ncold authized dealer your serviceable. owner not Th number Temperature when TEMP flashes pushed. SET button refrigerat The "Back on operating System". Operating Up Service Ncold authized dealer your serviceable. owner not Th "H" within fault a Th controls. refrigerat Service Ncold authized dealer your serviceable. owner not Th "r" within fault a Th controls. refrigerat Service Ncold authized dealer your serviceable. owner not Th "S" within fault a Th controls. refrigerat Service Ncold authized dealer your serviceable. owner not Th Art01504

13 Fault Codes (N64X, N64XXX, N64XIM, N64XIMXX, N84X, N84XXX, N84XIM, and N84XIMXX models) Fault Codes No dplay. " dr " Audible alarm also. " no " " FL " Audible alarm also. " no " " AC " Audible alarm also. " AC " " LO " " dc " " LO " " no " " co " Audible alarm also. Temperature number flashes when TEMP SET button pushed. " AC " " re " Audible alarm also. " dc " " re " Audible alarm also. " AC " " HE " Audible alarm also. " dc " " HE " Audible alarm also. " Sr " Audible alarm also. Fault Code Meaning DC voltage unavailable to refrigerat control panel refrigerat OFF. The do was open f me than 2minutes. The burner did not ignite reignite. AC voltage unavailable to refrigerat control. AC voltage to refrigerat control panel too low. DC voltage to refrigerat control panel too low. The refrigerat cooling unit has stopped cooling. The refrigerat operating on "Back Up Operating System". Th a fault within refrigerat controls. Th a fault within refrigerat controls. Th a fault within refrigerat controls. Th a fault within refrigerat controls. Th a fault within refrigerat controls. Crective Actions refrigerat ON. battery charging equipment of vehicle operational. AC/DC converter operational (if applicable). your dealer a Ncold authized service center. Close do. valve of propane gas tank(s) open. propane gas at crect pressure. manual shut off valve of refrigerat open. re no air in propane gas supply line. "Removing air from propane gas supply lines" section of th manual. your dealer authized Ncold Service refrigerat plugged into a serviceable outlet. fuse circuit breaker of vehicle intact. vehicle generat operational (if applicable). your dealer authized Ncold Service AC voltage to refrigerat crect. vehicle generat operational (if applicable). your dealer authized Ncold Service battery charging equipment of vehicle operational. AC/DC converter operational (if applicable). your dealer authized Ncold Service 1st time Befe reset vents are not blocked. a do(s) not open. Close do(s). vehicle level. 2nd time After reset Th not owner serviceable. Th not Th not Th not Th not Th not Th not owner serviceable. owner serviceable. owner serviceable. owner serviceable. owner serviceable. owner serviceable. your dealer authized Ncold Service your dealer authized Ncold Service your dealer authized Ncold Service your dealer authized Ncold Service your dealer authized Ncold Service your dealer authized Ncold Service your dealer authized Ncold Service Art01505 Installation Manual 13

14

15

16

17

18

12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker.

12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker. Installation Manual For 1200ACXX models: For 120XAC-IMXX models: 12.0 cu.ft., 2-way, 4-door, R.V. refrigerator. 12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker. The letter X, in the model

More information

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC ) Installation Manual For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC ) N404M.3 (128 liter 3-way operation with LP gas, 240 volts AC, or 12

More information

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator. Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N260.3 - a 2.4 cu. ft., 3-way refrigerator. NORCOLD, Inc. P.O. Box 4248 Sidney, OH 45365-4248 Part No. 619260A (4-98) Table

More information

Installation Requirements for Models:

Installation Requirements for Models: 900 & 9100 Series Refrigerators Installation Requirements for Models: 9162 9163 9182 9183 962 963 982 983 WARNING Improper installation, adjustment, alteration, service, or maintenance can cause injury

More information

Owner s Manual. For N41X models cu. ft., 2-way or 3-way, refrigerators. For N51X models cu. ft., 2-way or 3-way, refrigerators.

Owner s Manual. For N41X models cu. ft., 2-way or 3-way, refrigerators. For N51X models cu. ft., 2-way or 3-way, refrigerators. Owner s Manual F N41X models 4.5 cu. ft., 2way 3way, refrigerats. F N51X models 5.5 cu. ft., 2way 3way, refrigerats. The model numbers of 3way refrigerats include.3. The model numbers of 2way models do

More information

Installation and Owner s Manual For model 322X - a 1.7 cu. ft., 2-way refrigerator. For model 323X - a 1.7 cu. ft., 3-way refrigerator.

Installation and Owner s Manual For model 322X - a 1.7 cu. ft., 2-way refrigerator. For model 323X - a 1.7 cu. ft., 3-way refrigerator. Installation and Owner s Manual For model 322X - a 1.7 cu. ft., 2-way refrigerator. For model 323X - a 1.7 cu. ft., 3-way refrigerator. The model numbers of 3-way refrigerators contain.3. The model numbers

More information

Installation and Owner s Manual

Installation and Owner s Manual Installation and Owner s Manual For Australian refrigerator model: N604.3 (181 liter 3-way operation with propane gas, 240 volts AC, or 12 volts DC ) WARNING: Improper installation, adjustment, alteration,

More information

Installation and Owner s Manual

Installation and Owner s Manual Installation and Owner s Manual For Australian refrigerator models: N301 (93 liter 2-way operation with propane gas or 240 volts AC) N301.3 (93 liter 3-way operation with propane gas, 240 volts AC, or

More information

Owner s Manual. For Australian refrigerator models: N304.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

Owner s Manual. For Australian refrigerator models: N304.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC ) Owner s Manual For Australian refrigerator models: N304.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC ) N404.3 (128 liter 3-way operation with LP gas, 240 volts AC, or 12 volts

More information

RV REFRIGERATOR LP-GAS & ELECTRIC

RV REFRIGERATOR LP-GAS & ELECTRIC LITERATURE NUMBER MPD 4003333 RV REFRIGERATOR LP-GAS & ELECTRIC HE-0601, HE-0801 PROTECTED BY US PATENTS PENDING avoid possible injury or death SAFETY ALERT SYMBOLS Safety Symbols alerting you to potential

More information

8 cu.ft., 2-way, R.V. refrigerators.

8 cu.ft., 2-way, R.V. refrigerators. Owner s Manual For N61X models: For N81X models: 6 cu.ft., 2-way, R.V. refrigerators. 8 cu.ft., 2-way, R.V. refrigerators. WARNING: Improper installation, adjustment, alteration, service or maintenance

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS 682 683 662 663 652 653 6182 6183 6162 6163 6052 6053 WARNING Improper installation, adjustment, alteration, service, or maintenance can cause injury or property

More information

Service Manual Model 3163

Service Manual Model 3163 Service Manual Model 3163 Contents Important Safety Information.......... 1 Specifications.................. 2 General Information.............. 2 Direct Vent Requirements........... 2 Propane System................

More information

Northwest RV Supply Manual Compliments of Printed From 900 & 9100 Series

Northwest RV Supply Manual Compliments of Printed From 900 & 9100 Series 900 & 9100 Series Service Manual & Parts List for Models 9182 9183 9162 9163 982 983 962 963 Safety Information............... 1 Introduction................... 2 Specifications.................. 3 Operating

More information

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING By CNP INDUSTRIES, INC. P.O. Box 18645 Anaheim, Ca 92817 (877) 387-6721 INSTALLATION INSTRUCTIONS GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D IMPORTANT: Before beginning installation please read these

More information

Installation and Owner s Instructions

Installation and Owner s Instructions Installation and Owner s Instructions Water Dpenser Th refrigerat equipped with an optional dpenser. Installation Manual and Owner s Manual do include instructions about th option. Please use se instructions

More information

For N61X models: 6 cu.ft., 2-way, R.V. refrigerators. For N81X models: 8 cu.ft., 2-way, R.V. refrigerators.

For N61X models: 6 cu.ft., 2-way, R.V. refrigerators. For N81X models: 8 cu.ft., 2-way, R.V. refrigerators. Owner s Manual For N61X models: 6 cu.ft., 2-way, R.V. refrigerators. For N81X models: 8 cu.ft., 2-way, R.V. refrigerators. The letter X, in the model number above, stands for a letter or a numeral which

More information

GAS COOKTOP INSTALLATION INSTRUCTIONS

GAS COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. WARNING If the information

More information

UPPER & LOWER SIDE VENT INSTALLATION

UPPER & LOWER SIDE VENT INSTALLATION UPPER & LOWER SIDE VENT INSTALLATION FOR NORCOLD MODELS 900/9100/N600/N800 Read these important instructions carefully. Become thoroughly acquainted with the content before installing vents and refrigerator.

More information

MODEL 1082 FREE-STANDING REFRIGERATOR

MODEL 1082 FREE-STANDING REFRIGERATOR Service Manual MODEL 1082 FREE-STANDING REFRIGERATOR Specifications AC.............. 120 VAC, 60 Hertz......... 132 VAC Max. - 108 VAC Min. Heater............ Power - 300 Watt............. Current - 2.7-2.9

More information

Literature number hydro flame AFS Series Furnaces Models AFSAD12 AFSD12, AFSD16, AFSD20. Technical Installation Manual WARNING WARNING

Literature number hydro flame AFS Series Furnaces Models AFSAD12 AFSD12, AFSD16, AFSD20. Technical Installation Manual WARNING WARNING Literature number 31970 hydro flame AFS Series Furnaces Models AFSAD12 AFSD12, AFSD16, AFSD20 1120 North Main Street Elkhart, IN 46514 USA & Canada : 1-866-869-3118 Internet: http://www.atwoodmobile.com

More information

GAS COOKTOP INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN. IMPORTANT Save these instructions for local electrical inspector s use.

GAS COOKTOP INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN. IMPORTANT Save these instructions for local electrical inspector s use. GAS COOKTOP INSTALLATION INSTRUCTIONS Please read this guide thoroughly before installation. To contact LG Electronics, 24 hours a day, 7 days a week: 1-800-243-0000 (U.S.A.) 1-888-542-2623 (Canada) Or

More information

12.0 cu.ft., 2-way, 4-door, R.V. refrigerator with ice maker.

12.0 cu.ft., 2-way, 4-door, R.V. refrigerator with ice maker. Owner s Manual For 1200XX models: For 120X-IMXX models: 12.0 cu.ft., 2-way, 4-door, R.V. refrigerator. 12.0 cu.ft., 2-way, 4-door, R.V. refrigerator with ice maker. The letter X, in the model numbers above,

More information

CBO-750 HYBRID-R OVEN Instructions Manual

CBO-750 HYBRID-R OVEN Instructions Manual CBO-750 HYBRID-R OVEN Instructions Manual ELECTRICAL DIAGRAM IS LOCATED BEHIND FRONT PANEL THIS OVEN MAY BE OPERATED OUTDOORS. ELECTRICAL DIAGRAMS ARE LOCATED BEHIND FRONT PANEL. KEEP THIS MANUAL FOR FUTURE

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction

More information

Using it in an enclosed space can kill you.

Using it in an enclosed space can kill you. 38 X 56 GAS FIRE PIT - OWNER S MANUAL Carlisle Chat Fire Table Base Model # 00GBC7 (6877B) Fits 6877A Carlisle Chat Fire Table Top For Propane and *Natural Gas (*See Page 7) Certified to CSA International

More information

Installation Instructions

Installation Instructions WARNING! INSTALLATION SAFETY INSTRUCTIONS Read these instructions completely and carefully. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer

More information

installation manual DM3862 RM2554 DM2663 RM2551 Refrigerator for LP-gas & electric operation DM2852 ! AVERTISSEMENT ! WARNING FOR YOUR SAFETY

installation manual DM3862 RM2554 DM2663 RM2551 Refrigerator for LP-gas & electric operation DM2852 ! AVERTISSEMENT ! WARNING FOR YOUR SAFETY RM25 RM254 RM245 RM2454 RM255 RM2554 DM2652 DM2662 DM266 DM2852 DM2862 DM862 NDM062 NDR292 installation manual Refrigerator for LP-gas & electric operation FOR YOUR SAFETY If you smell gas:. Open windows.

More information

GPC PASTA PRO INSTALLATION & USER OPERATION MANUAL

GPC PASTA PRO INSTALLATION & USER OPERATION MANUAL GPC-14/18/20 GPC PASTA PRO INSTALLATION & USER OPERATION MANUAL GPC-18 shown with optional rinse station. NOTICE! After installation of your equipment, immediately contact your local gas supplier to obtain

More information

Certified to ANSI Z / CSA4.3

Certified to ANSI Z / CSA4.3 ciapmo-t 11 Sunnybrook Drive Cincinnati, OH. 45237 Certified to ANSI Z21.10.3 / CSA4.3 Phone: 513-641-4446 * 800-934-9690 Fax: 513-641-0733 www.precisiontemp.com LPG GAS ON DEMAND WATER HEATER Model RV-550

More information

LPG GAS ON DEMAND WATER HEATER. Model RV-550

LPG GAS ON DEMAND WATER HEATER. Model RV-550 LPG GAS ON DEMAND WATER HEATER 11 Sunnybrook Drive Cincinnati, OH. 45237 Phone: 513-641-4446 * 800-934-9690 Fax: 513-641-0733 www.precisiontemp.com Model RV-550 This water heater design has been certified

More information

Installation Instructions Dual Fuel Ranges

Installation Instructions Dual Fuel Ranges Installation Instructions Dual Fuel Ranges E30DF74EPS E36DF76EPS E48DF76EPS 5995447082 2 Safety IMPORTANT SAFETY INSTRUCTIONS Safety Precautions Do not attempt to install or operate your unit until you

More information

Installation Instructions

Installation Instructions Installation Instructions for Dryers Inside... Dimensions... Before You Start... 4 Installing the Dryer... 5 Installer Checklist... Back Cover Date Purchased Model Number Serial Number Keep these instructions

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For F-1000T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired

More information

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER A Division of THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented /

More information

Installation Instructions

Installation Instructions Instructions for Dryers Original Instructions Keep These Instructions for Future Reference. CAUTION: Read the instructions before using the machine. (If this machine changes ownership, this manual must

More information

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents Installation Instructions T 9822 Gas Dryer To prevent accidents en - US, CA and appliance damage read these instructions before installation or use. M.-Nr. 07 431 110 2 WARNING For your safety the information

More information

INSTALLATION GUIDE Dual Fuel Ranges

INSTALLATION GUIDE Dual Fuel Ranges INSTALLATION GUIDE Dual Fuel Ranges Contents Wolf Dual Fuel Ranges......................... 3 Safety Instructions............................ 4 Dual Fuel Range Specifications.................. 5 Dual Fuel

More information

SS1095 Ice Maker.

SS1095 Ice Maker. Installation Guide SS1095 Ice Maker www.u-lineservice.com Phone (414) 354-0300 FAX (414) 354-7905 Service & Parts Tech Lines Phone (800) 779-2547 FAX (414) 354-5696 OnlineService@U-Line.com 2008 U-Line

More information

INSTALLATION AND OPERATION INSTRUCTIONS FOR

INSTALLATION AND OPERATION INSTRUCTIONS FOR INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-40-DEEP-XT BI-50-DEEP-XT BI-60-DEEP-XT BI-72-DEEP-XT BI-88-DEEP-XT SAFETY INFORMATION WARNING If the information in these instructions are not followed exactly,

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For F-400T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired

More information

THC-175DF INDUSTRIAL / COMMERCIAL SPACE HEATER. Certified to / Certifié à CGA 2.14 M2011 Conforms to / Conforme à ANSI std Z83.

THC-175DF INDUSTRIAL / COMMERCIAL SPACE HEATER. Certified to / Certifié à CGA 2.14 M2011 Conforms to / Conforme à ANSI std Z83. THC-175DF INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2011 Conforms to / Conforme à ANSI std Z83.7 2011 Suitable for indoor or outdoor installation / Unvented / Unattended

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction

More information

DESIGN CLASS FUNCTION

DESIGN CLASS FUNCTION PROFESSIONAL QUALITY COOKING EQUIPMENT INSTALLATION MANUAL FOR PERFORMER SLIDE-IN COOK TOPS MODEL NUMBERS: AROBSCT-424, AROBSCT-242GD, AROBSCT-24X2GR, AROBSCT-430, AROBSCT-636, AROBSCT-436GD, AROBSCT-436GR,

More information

Installation Instructions

Installation Instructions Installation Instructions Gas & Electric Dryer Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the dryer is installed correctly and safely.

More information

OPERATING INSTRUCTIONS AND OWNER S MANUAL

OPERATING INSTRUCTIONS AND OWNER S MANUAL OPERATING INSTRUCTIONS AND OWNER S MANUAL MR. HEATER READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For F-1500T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction

More information

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at: Installation Instructions If you have questions, call 800-GE-CARES or visit our website at: www.monogram.com 36" Stainless Steel Gas Cooktops Natural Gas Model: ZGU375NS LP Gas Model ZGU375LS Monogram.

More information

INSTALLATION AND OPERATION INSTRUCTIONS FOR SAFETY INFORMATION WARNING

INSTALLATION AND OPERATION INSTRUCTIONS FOR SAFETY INFORMATION WARNING INSTALLATION AND OPERATION INSTRUCTIONS FOR 102735-XS 102745-XS 102755-XS 102765-XS SAFETY INFORMATION WARNING If the information in these instructions are not followed exactly, a fire or explosion may

More information

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS BI-40-DEEP BI-50-DEEP BI-60-DEEP BI-72-DEEP BI-88-DEEP SAFETY INFORMATION WARNING If the information in these instructions are not followed exactly,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS BUILT-IN BOTTOM MOUNT REFRIGERATOR/FREEZER DBRTGK72SS-GRILLE KIT (FOR designer SERIES ONLY) VIKING RANGE CORPORATION 111 Front Street Greenwood, Mississippi (MS) 38930 USA (662)

More information

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended

More information

Installation instructions for the T 9820 Gas Dryer

Installation instructions for the T 9820 Gas Dryer Installation instructions for the T 9820 Gas Dryer The T 9820 gas dryer is only approved for use in the USA and Canada. It is not approved for use in Mexico. To prevent accidents en - US, CA and machine

More information

Installation Guide BI-98 Ice Maker www.u-lineservice.com Phone (414) 354-0300 FAX (414) 354-7905 Service & Parts Tech Lines Phone (800) 779-2547 FAX (414) 354-5696 OnlineService@U-Line.com 2005 U-Line

More information

ELECTRIC FIREPLACE HEATER OPERATION MANUAL

ELECTRIC FIREPLACE HEATER OPERATION MANUAL ELECTRIC FIREPLACE HEATER OPERATION MANUAL Important Safety Instructions: PLEASE RETAIN THIS USER S GUIDE FOR FUTURE REFERENCE When using electrical appliances, basic precautions should always be followed

More information

Installation Instructions

Installation Instructions Instructions for Dryers Original Instructions Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) www.speedqueen.com Part No. D5439R2

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

Service Manual Gas/Electric Refrigerators

Service Manual Gas/Electric Refrigerators Service Manual Gas/Electric Refrigerators MODELS N61X/N81X N62X/N82X N64X/N84X N64XIM/N84XIM N64X.3/N84X.3 WARNING DO T install this refrigerator in below deck marine applications. Do not install this

More information

Installation Instructions

Installation Instructions Instructions for Stacked Dryers Original Instructions Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) www.speedqueen.com Part No.

More information

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure) ASSEMBLY INSTRUCTIONS - NXS SERIES OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED RADIANT

More information

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS WM-FM-50-BG SAFETY INFORMATION WARNING If the information in these instructions are not followed exactly, a fire or explosion may

More information

Installation Instructions

Installation Instructions Instructions for Dryers Original Instructions Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) www.speedqueen.com Part No. 5439R October

More information

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40 INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40 CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, CANADA, M3N 1V9 TELEPHONE: (416) 746-2358, FAX: (416)

More information

Multi-Function Cooktop

Multi-Function Cooktop INSTALLATION GUIDE Multi-Function Cooktop Contents Wolf Multi-Function Cooktop.................... 3 Multi-Function Cooktop Specifications............ 4 Multi-Function Cooktop Installation...............

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range Corporation Front Street Greenwood, Mississippi 38930 USA (66) 455-00 For product information, call -888-VIKING (845-464) or visit the Viking Web site at vikingrange.com

More information

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G PGM-1 Cooktops For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G Install ation Instructions Part No. 65476 Rev. B Table of Contents Appliance Safety...1 Important Safety Instructions...2

More information

Fig. 1 - Unit PGD4, PGS4, WPG4

Fig. 1 - Unit PGD4, PGS4, WPG4 OWNER S MANUAL 14 SEER Single -Package Air Conditioner and Gas Furnace System with R -410A Refrigerant Single Phase 2 to 5 Nominal Tons Three Phase 3 to 5 Nominal Tons PGD4andPGS4SeriesE,WPG4SeriesB Fig.

More information

Installation and Operation Instructions ELECTRIC FIREPLACE X30WMEF1BLK X30WMEF1WHT

Installation and Operation Instructions ELECTRIC FIREPLACE X30WMEF1BLK X30WMEF1WHT Installation and Operation Instructions ELECTRIC FIREPLACE X30WMEF1BLK X30WMEF1WHT 1 Important Safety Instructions Listing Approvals Product Dimensions Locating Fireplace Unpacking and Testing Fireplace

More information

INSTALLATION INSTRUCTIONS FOR FREESTANDING DUAL FUEL

INSTALLATION INSTRUCTIONS FOR FREESTANDING DUAL FUEL INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. If the information in this

More information

GAS COOKTOP INSTALLATION INSTRUCTIONS

GAS COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. WARNING If the information

More information

Owner s Information Manual

Owner s Information Manual 48ES---A and 48VL---A Comfort and Performance 13 and 14 SEER Single Packaged Air Conditioner and Gas Furnace System With Puron (R---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60)

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS BUILT-IN BOTTOM MOUNT REFRIGERATOR/FREEZER BRTGK72SS-GRILLE KIT (FOR PROFESSIONAL SERIES ONLY) VIKING RANGE CORPORATION 111 Front Street Greenwood, Mississippi (MS) 38930 USA

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-200 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended

More information

Installation Guide. 5 Series VGC and VGSU Built-In Gas Cooktops

Installation Guide. 5 Series VGC and VGSU Built-In Gas Cooktops Installation Guide 5 Series VGC and VGSU Built-In Gas Cooktops Table of Contents Warnings & Important Safety Instructions 3 Dimensions VGC Cooktops 6 Specifications VGC Cooktops 7 Dimensions VGSU Cooktops

More information

INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION INSTRUCCIONES DE INSTALACIÓN

INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION INSTRUCCIONES DE INSTALACIÓN EN FRONT LOAD DRYER FR SÉCHEUSE Á CHARGEMENT FRONTAL ES SECADORA DE CARGA FRONTAL INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION INSTRUCCIONES DE INSTALACIÓN 2 IMPORTANT SAFETY INSTRUCTIONS For

More information

INSTALLATION AND OPERATION INSTRUCTIONS FOR ZERO CLEARANCE AND INSERT UNITS

INSTALLATION AND OPERATION INSTRUCTIONS FOR ZERO CLEARANCE AND INSERT UNITS INSTALLATION AND OPERATION INSTRUCTIONS FOR ZERO CLEARANCE AND INSERT UNITS ZECL-26-2923-BG ZECL-30-3226-BG ZECL-33-3624-BG ZECL-39-4134-BG ZECL-2939-BG INSERT-26-3825-BG INSERT-30-4026-BG INSERT-33-4230-BG

More information

Installation Instructions

Installation Instructions Instructions for Dryers Original Instructions Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) www.alliancelaundry.com Part No. D5486ENR

More information

CINCINNATI, OH USA

CINCINNATI, OH USA INSTRUCTION MANUAL Part No. 89731 Revised October 1997 CINCINNATI, OH 45241-4807 USA GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells gas can be obtained from the local gas supplier.

More information

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

30 GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners) INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. If the information in this

More information

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS WM-FML-26-3223-STL WM-FML-34-4023-STL WM-FML-48-5523-STL WM-FML-60-6623-STL WM-FML-72-7823-STL WM-FML-88-9623-STL SAFETY INFORMATION

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range Corporation Front Street Greenwood, Mississippi 38930 USA (66) 455-00 For product information, visit the Viking Web site at vikingrange.com Professional Built-In

More information

Repeat procedures for other side.

Repeat procedures for other side. Repeat procedures for other side. ASSEMBLY INSTRUCTIONS Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. CSA Model 98900 Printed in China DANGER

More information

PrecisionTemp Shower-Mate

PrecisionTemp Shower-Mate Shower-Mate Instantaneous Gas Water Heater Installation and Operating Instructions The Shower-Mate is a power vented automatic instantaneous water heater designed to be installed in ventilated marine applications.

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS CSA Model 99000 ARL00100 Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. DANGER If you smell gas: 1. Shut off gas to the

More information

GAS -FIRED VENTED ROOM HEATERS MODEL 61TV

GAS -FIRED VENTED ROOM HEATERS MODEL 61TV GAS -FIRED VENTED ROOM HEATERS MODEL 61TV INSTALLATION MANUAL NEW BUCK CORPORATION WARNING: Improper installation, adjustment, alteration,service or maintenance can cause injury or property damage. Refer

More information

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler Gas boiler UPON COMPLETION OF THE INSTALLATION THE INSTALLER MUST INSTRUCT THE OWNER AND OPERATOR ON THE FUNCTIONALITY AND THE PROPER OPERATION OF THE BOILER AND THE HEATING SYSTEM. INSTALLER MUST REVIEW

More information

Installation Instructions

Installation Instructions Instructions for Dryers Original Instructions Keep These Instructions for Future Reference. CAUTION: Read the instructions before using the machine. (If this machine changes ownership, this manual must

More information

CYLINDER NOT INCLUDED

CYLINDER NOT INCLUDED OPERATING INSTRUCTIONS AND OWNER S MANUAL Model # HS125NG / MH125LP / HS125LP READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do

More information

DRAFT. Northwest RV Supply. Manual Compliments of. Printed From. Service Manual NOT FOR PUBLIC RELEASE

DRAFT.  Northwest RV Supply. Manual Compliments of. Printed From. Service Manual NOT FOR PUBLIC RELEASE Service Manual Gas/Electric Refrigerators MODELS N500 N510! WARNING DO T install this refrigerator in below deck marine applications. Do not install this refrigerator in fixed indoor cabin or other dwelling

More information

DESIGN CLASS FUNCTION

DESIGN CLASS FUNCTION PROFESSIONAL QUALITY COOKING EQUIPMENT INSTALLATION MANUAL FOR MEDALLION DUAL FUEL RANGES MODEL NUMBERS: ARR-304DF, ARR-366DF, ARR-364GDDF, ARR-364GRDF, ARR-486GDDF, ARR-486GRDF, ARR-4822GDDF, ARR-484X2GRDF,

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction

More information

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended

More information

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies PME Series Enclosures Battery Enclosure (BE) Field Upgrade Installation Instructions Effective: January, 2004 Alpha Technologies Power Alpha Technologies. Protecting The Power in Communications. Preface

More information

EL195DFE SERIES GAS FURNACE WARNING

EL195DFE SERIES GAS FURNACE WARNING 2011 Lennox Industries Inc. Dallas, Texas, USA 506739 01 06/2011 EL195DFE SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could result in serious injury,

More information

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS CSA Model 98300 DRF01000 Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. DANGER If you smell gas: 1.

More information

Installation and Operation Instructions ELECTRIC FIREPLACE X56WMEF1BLK X56WMEF1WHT

Installation and Operation Instructions ELECTRIC FIREPLACE X56WMEF1BLK X56WMEF1WHT Installation and Operation Instructions ELECTRIC FIREPLACE X56WMEF1BLK X56WMEF1WHT Tool list Assembly Instructions Important Safety Instructions Listing Approvals Glass Particles Installation Instructions

More information

Installation Instructions

Installation Instructions Installation Instructions Full Size Laundry Center Gas & Electric Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the laundry center is

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at