Diaphragm pumps. Operation Manual. Models: 2019C-02 (230V / 50Hz) 2019B-01 (115V / 60Hz) 2019C-50 (230V / 50Hz)

Size: px
Start display at page:

Download "Diaphragm pumps. Operation Manual. Models: 2019C-02 (230V / 50Hz) 2019B-01 (115V / 60Hz) 2019C-50 (230V / 50Hz)"

Transcription

1 Operation Manual (EN) Translation of the german original manual Diaphragm pumps Models: 2019C-02 (230V / 50Hz) 2019B-01 (115V / 60Hz) 2019C-50 (230V / 50Hz)

2 We are constantly working on the further development of all our product models. Reprinting or reproduction of this manual, including extracts, is not allowed without the prior written permission of Co. Gardner Denver Thomas GmbH. All rights under the copyright laws are expressly reserved by Co. Gardner Denver Thomas GmbH. We reserve the right to make changes and amendments. Gardner Denver Thomas GmbH Am Vogelherd Ilmenau Germany T F welch.emea@gardnerdenver.com Customer Support For USA, Canada and other Americas Gardner Denver Thomas, Inc Feehanville Drive Suite 550 Mt. Prospect, IL USA T F welch.na@gardnerdenver.com

3 Contents Contents 1 Important Information General Information Target Groups Intended Use Use for an Unauthorized Purpose Safety Devices Meaning of the Warning notes Product Standards, Safety Regulations Basic Safety Instructions General Information Electricity Mechanical Systems Hazardous Substances High Temperatures Description Design Connections - Suction- / Pressure side Connecting to the electricity supply Display - Vacuum Regulator Protection measures against liquids in the pump Condensate separator (Suction side) Cold trap (Suction side) Areas of Application Materials of the medium-affecting pump parts Scope of Delivery Accessories Technical Data Installation and Operation Unpacking Setting up and connecting Setting up Connecting Electrical Connection Vacuum connection (Suction side) Exhaust connection (Pressure side) Operation Start-up Decommissioning Storage Scrap Disposal Maintenance and Servicing Maintenance Performed by the User Diaphragm replacement Maintenance by the Manufacturer Damage Report Troubleshooting Spare Parts Overview Kit Order numbers Diaphragm pump with vacuum regulator kit C Spare parts view / Parts list

4 Important Information 1 Important Information 1.1 General Information The Diaphragm Pumps conform to the following directives: 2006 / 42 / EC Machinery Directive 2014 / 30 / EU Electromagnetic Compatibility Directive The CE sign is located on the rating plate. Observe the binding national and local regulations when fitting the pump into installations! 1.2 Target Groups This Operating Manual is intended for the personnel planning, operating and maintaining Diaphragm Pumps. This group of people includes: Designers and fitters of vacuum apparatus Employees working on commercial laboratory and industrial vacuum technology applications Service personnel for Diaphragm Pumps The personnel operating and maintaining the Diaphragm Pumps must have the technical competence required to perform the work that has to be done. The user must authorize the operating personnel to do the work that has to be done. The personnel must have read and understood the complete Operating Manual before using the Diaphragm Pumps. The Operating Manual must be kept at the place of use and be available to the personnel when required. 1.3 Intended Use The layout of the Diaphragm Pumps must be appropriate for the conditions of use. The user bears the sole responsibility for this. The Diaphragm Pumps may only be operated under the conditions stated in the "Technical Data" section, on the type plate, and in the technical specification for the order concerned. Diaphragm Pumps are approved for extracting, pumping and compressing gases and vapours. If these gases and vapours are toxic or explosive, then the user must observe the currently valid safety regulations for this application. 1.4 Use for an Unauthorized Purpose It is forbidden to use the pump for applications deviating from the technical data stated on the type plate or the conditions stated in the supply contract, or to operate it with missing or defective protective devices

5 Important Information 1.5 Safety Devices Measures such as the following are for the safety of the operating personnel: electrical connection with a protective conductor (operating mode S1) and an earthing plug Motor protection device (thermal) Hot Surface" label on the pump - warning notice The Diaphragm Pumps must not be operated without these elements. 1.6 Meaning of the Warning notes Take note of the warning notices. They are each in the following box: CAUTION! / WARNING! Hazard which may lead to serious injuries or material damage. 1.7 Product Standards, Safety Regulations Diaphragm Pumps meet the following product standards: DIN EN ISO 12100: Safety of machinery - General principles for design - Risk assessment and risk reduction DIN EN ISO 13857: Safety of machinery - Safety distances to prevent hazard zones being reached by upper and lower limbs Compressors and Vacuum pumps - Safety requirements - DIN EN : Part 2: Vacuum pumps DIN EN ISO 2151: Acoustics - Noise test code for compressors and vacuum pumps - Engineering method (grade 2) DIN EN : Safety of machinery - Electrical equipment of machines - Part 1: General requirements Electromagnetic compatibility (EMC) - DIN EN : DIN EN : Part 6-2: Generic standards - Immunity for industrial environments Part 6-4: Generic standards - Emission standard for industrial environments DIN EN /A1: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements DIN EN : Operation of electrical installations Directive 2012/19/EU Electrical and electronics - old devices (WEEE) Directive 2011/65/EU Dangerous materials in electrical and electronics devices (RoHS II) China RoHS II Environment protection law - China The following additional safety regulations apply in the FR Germany: BGV A3 VBG 5 BGR 120 BGI 798 BGG 919 (VBG 16) BGR 189 (BGR 195;192;197) Electrical equipment and operating materials Power-driven machines Guidelines for laboratories Hazard assessment in the laboratory Accident prevention regulations for "compressors" Use of protective working clothes Observe the standards and regulations applying in your country when you use the Diaphragm Pumps

6 Basic Safety Instructions 2 Basic Safety Instructions 2.1 General Information Warning notices must be observed. Disregarding them may lead to damage to health and property. The Diaphragm Pumps must be operated by personnel who can detect impending dangers and take action to prevent them from materialising. The manufacturer or authorized authorised workshops will only service or maintain the Diaphragm Pumps if it is accompanied by a fully completed damage report. Precise information about the contamination (also negative information if necessary) and thorough cleaning of the Diaphragm Pumps are legally binding parts of the contract. Contaminated Diaphragm Pumps and their individual parts must be disposed of in accordance with the legal regulations. The local regulations apply in foreign countries. 2.2 Electricity The Diaphragm Pumps of operation mode S1 are supplied. When the location of operation mode S1 devices is changed, please note that the testing must be repeated in accordance with DIN EN 0105, DIN EN 0702 and BGV A2. The local regulations apply in foreign countries. Please note the following when connecting to the electrical power supply system: The electrical power supply system must have a protective connector according to DIN VDE (IEC ). The protective connector must not have any breaks. The connecting cable must not be damaged. 2.3 Mechanical Systems Improper use can lead to injuries or material damage. Observe the following instructions: Only operate the pumps with hoses of the specified dimensions. The maximum permissible pressure of 1 bar at the suction connection must not be exceeded. Hazardous substances must be separated out as far as this is technically possible before they reach the pump. External mechanical stresses and vibrations must not be transmitted to the pump. Only use flexible laboratory hoses for connecting pumps. The overpressure generated at the pressure port must not exceed 1 bar. The pump must not be used to suck up fluids. Lay the exhaust pipe so that it slopes downwards, so allowing condensate to flow out of the pump. Collect the condensate and dispose of it in an environmentally compatible manner. Prevent dyes exuding. Maintain a space of least 20 mm between the pump and adjacent parts in order to enable the pump to cool. CAUTION! Solid particles in the pumping medium impair the pumping action and can lead to damage. Prevent solid particles penetrating into the pump

7 Basic Safety Instructions 2.4 Hazardous Substances ACHTUNG! The operating company bears the responsibility for the use of the Diaphragm Pumps. Hazardous substances in the gases to be pumped can cause personal injuries and property damage. Pay attention to the warning notices for handling hazardous substances. The local regulations apply in foreign countries. Combustible, aggressive and explosive Gases Don t pump combustible, especially aggressive or explosive gases or vapors or operate this pump in an atmosphere containing combustible or explosive gases or vapors. Examine before switching on whether that can form gas combustible gas/air mixtures which can be promoted! Consider the regulations of the guideline 1999/92/EC. The Diaphragm Pumps are not certified according to ATEX guidelines 2014/34/EU. The Diaphragm Pumps are not recommended for pumping acidic, basic or organic vapors. Poisonous Gases Use a suitable separator when pumping poisonous or harmful gases. Prevent such substances from leaking out of the appliance or pump. Treat these substances according to the applicable environmental protection regulations. Test the strength and leak-tightness of the connecting lines and the connected apparatus. Prevent environmental poisons, e.g. mercury, getting into the pumps. Fulfil the requirements, for example: German Hazardous Substances Regulation (GefStoffV) of 01. December 2010 Regulation 2016/1179/EU (Classification, Packaging and Labelling of hazardous substances), Manufacturer's safety data sheets on hazardous substances. 2.5 High Temperatures The Diaphragm Pumps may heat up as a result of the temperature of the gas being pumped and through compression heat. Prevent the following maximum permissible temperatures from being exceeded C for the environment, and + 60 C for the gas to be pumped. The electric motor has a thermal overload protection

8 Description 3 Description 3.1 Design Connections - Suction- / Pressure side Vacuum connection Suction side (1) Exhaust connection Pressure side (2) Suction side - Connection: Hose nozzle DN 8 (1) Pressure side - Connection: Exhaust silencer (2) or hose nozzle DN 8 (3) Suction side - Connection: Vacuum Regulator - Kit (3) with separator and display With the help of suction-side mounted Regulator-Kit it is possible to regulate the final pressure of the pump. You can see the actual pressure at the manometer Connecting to the electricity supply The Diaphragm Pumps are supplied with complete electrical wiring. It is connected via a mains connection cable and a power plug. Mains connection cable and plug must comply with the requirements of the line disconnection devices (current, output). Motor is provided with a thermal overload protection ex works, protecting the vacuum pump from damage or destruction, respectively. WARNING! Should the user change the electrical connection, for example for fitting into a system, then this may only be performed by a electrical specialist under observance of the accident prevention regulations

9 Description Display - Vacuum Regulator The Vacuum Regulator shows pressures at below atmospheric pressure. The reference point for the gauge is atmospheric pressure. WARNUNG! Please keep in mind that the barometric pressure changes from day to day. This also changes the displayed pressure values because of latent air pressure fluctuations. 3.2 Protection measures against liquids in the pump Condensate separator (Suction side) If the possibility of penetration of larger liquid quantities, we recommend the additional installation of a larger collection vessel (eg. Woulff bottle) Cold trap (Suction side) The installation of an appropriate cold trap is required when a larger amount of steam (water, solvent) is obtained which exceeds the tolerance of the vapor pump. The refrigerant used is usually dry ice or dry ice mixture with an acetone or alcohol. Maintenance: The refrigerant must have the highest possible level in the cold trap. The rise in pressure in the connected vacuum apparatus indicates that the cold trap is saturated. For cleaning remove the cold trap and defrost. The condensate must be disposed of properly. The cool trap is, if applicable, clean with a detergent and dry. 3.3 Areas of Application The Diaphragm Pumps are intended to: Pumping and compressing neutral and aggressive gases and vapours. Generating a vacuum down to a minimum ultimate pressure of 200 mbar. Use in physical and chemical laboratories in trade and industry. Use for vacuum filtration, vacuum drying, glove boxes, vacuum ovens and other vacuum technology applications

10 Description 3.4 Materials of the medium-affecting pump parts Component Materials Seal Hose nozzle Piston cup seal Pump head Separator vessel EPDM PVDF PTFE - Compound Aluminium with corrosion protection Plastic 3.5 Scope of Delivery The scope of delivery is specified in the supply contract. 3.6 Accessories Figure Designation / Usage Order no. Inline filter, hydrophobic Pore size: 0.22 µm To protect the pump against fine dust and aerosols. Installation in the suction line, as shown Vacuum hose red, rubber 18 / 8 x 5 mm For vacuum applications between pump and apparatus PVC-Fabric hose 8 x 3 mm For compressor- and vacuum applications as exhaust air- and suction line Hose clamp Clamping range 8 16 mm For fixing and sealing of PVC fabric hose

11 Technical Data 4 Technical Data Parameter Unit 2019B C-02 Pumping speed 50/60 Hz at atmospheric pressure m 3 / h 1.9 / 2.3 l / min 31 / 37 Ultimate pressure mbar 200 Suction connection Pressure connection Ambient temperature Max. Operating gas temperature - C Hose nozzle DN 8 for hose inside diameter 8 mm Hose nozzle DN 8 for hose inside diameter 8 mm and Exhaust silencer + 10 to Voltage / Frequency V / Hz 115 / / 50 Type of protection DIN EN IP 20 Weight kg Dimensions (W/D/H) mm 224 / 127 / / 127 / 224 Order No. for: - Diaphragm pump inclusive mains connection cable with plug US - Diaphragm pump inclusive mains connection cable with plug CEE - Diaphragm pump inclusive mains connection cable with plug CEE and vacuum regulator - Kit B C C-50 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as and aid to help in the selection of products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Gardner Denver Thomas GmbH does not warrant, guarantee or assume any obligation or liability in connection with this information

12 Installation and Operation 5 Installation and Operation 5.1 Unpacking Carefully unpack the Diaphragm Pump. Check the pump for: Transport damage, Conformity with the specifications of the supply contract (model, electrical supply data), Completeness of the delivery. Please inform us without delay if there are discrepancies between the delivery and the contractually agreed scope of delivery, or if damage is detected. Please take note of the general terms of business of the manufacturing firm. In case of a claim under warranty, the device must be returned in packaging that is suitable for protecting it during transport. 5.2 Setting up and connecting Setting up Set the pump on a flat and horizontal surface. Remove the protective caps on the suction and pressure ports. Note that the cooling of the pump is guaranteed, see chapter 2.3. Note that on the installation location no moisture acts on the pump Connecting Electrical Connection Before the electrical connection of the pump review the specifications on the nameplate with the existing electrical connection conditions, see chapter 2.2. CAUTION! The electric motor has a thermal overload protection. After triggering the protective fuse after a certain cooling occurs an auto restart (Reset) the motor Vacuum connection (Suction side) The vacuum connection (suction port) consists of a hose nozzle DN 8. Suitable vacuum lines are available: Thick-walled rubber vacuum hose 8 x 5 mm hose nozzle DN 8. PVC fabric hose and hose clamp 8 x 3 mm clamping range 8-16 mm. Make sure that the vacuum line is kept as short as possible from the pump to the apparatus

13 Installation and Operation Exhaust connection (Pressure side) The exhaust connection (pressure port) also consists of a hose nozzle DN 8. Thick-walled rubber vacuum hose 8 x 5 mm hose nozzle DN 8. PVC fabric hose and hose clamp 8 x 3 mm clamping range 8-16 mm. 5.3 Operation CAUTION! Observe the basic safety instructions when using the Diaphragm Pump, chapter Start-up Make sure that when you start the pump, which may arise in the connection lines condensates, cannot penetrate into the pump. Action: additional suction side condensate separator Always try to avoid aspiration of foreign body particles! Action: suction side inline filter The Diaphragm pump is switched on the power switch. It is recommended to let the pump run for a few minutes before use. The warm-up improves the eligibility of the pump Decommissioning If vacuum applications with special steam load, the pump needs to run after the process with an open vacuum port about 2 minutes and rinsed with atmospheric air. This measure is used to cleaning the pump chamber and minimizes the corrosive attack wetted material pump parts. The Diaphragm pump is switched off using the power switch. 5.4 Storage The pumps are to be stored in a low-dust, interior room within the temperature range from + 5 to + 40 C and at a relative air humidity < 90%. Leave the protective elements on the suction and pressure ports. Another equally good protection may be used. 5.5 Scrap Disposal CAUTION! The Diaphragm Pumps must be disposed of in accordance with the 2012/19/EU guideline and the specific national regulations. Contaminated Diaphragm Pumps must be decontaminated according to the laws

14 Maintenance and Servicing 6 Maintenance and Servicing Diaphragm Pumps are 100% oil-free. All bearings are sealed and permanently lubricated. 6.1 Maintenance Performed by the User WARNING! Only perform the work that is described here, and that which is permitted to be done by the user. All other maintenance and service work may only be performed by the manufacturer or a dealer authorized by him. Beware of the pump parts being possibly contaminated by hazardous substances. Wear protective clothing if there is contamination. Renew defective parts, if necessary! Do not clean with compressed air! Check the pump daily for unusual running noises and heat building up on the surface of the pump. Check the electrical and vacuum connections daily Diaphragm replacement Disassembling the diaphragms: Disconnect power. Note: Observe the position of the air intake port (B) and exhaust port (A) before disassembly. Remove the six screws from head (with handle) and place the head with the screws aside. Remove the four screws from valve plate and remove them. Now remove the diaphragm with the PTFE diaphragm liner and discard it. Reassembling the diaphragms: Wipe top of connecting rod clean with a soft clean cloth. Place new diaphragm with PTFEdiaphragm liner on top of connecting rod. Line up the holes in the diaphragm and liner with the screw holes in connecting rod. Screw the four screws crosswise with a torque of 3-4 Nm

15 Maintenance and Servicing WARNING! To prevent damage to the pump, never apply any sealant or lubrication to the gasket. Valve plate replacement: Wipe inside of head clean. Install new gasket if needed, be sure to remove any excess gasket. Replace valve plate in head. Chamfer side of valve plate should face you. Insert four new screws. Screw the four screws crosswise with a torque of 3-4 Nm. Reassembling the pump: Place the head (with handle) on the pump casing, observing the position of the air intake port (B) and exhaust port (A). Note: Make sure the diaphragm is seated properly in the well of the pump casing and head. Do not pinch the diaphragm or liner. Insert the screws on the head (with handle). Do not completely tighten the screws yet. Now screw the four screws crosswise with a torque of 5-6 Nm

16 Maintenance and Servicing 6.2 Maintenance by the Manufacturer Repairs and maintenance going beyond the extent of the work described in chapter 6.1 or reconditioning or modification may only be performed by the manufacturer or authorized workshops. WARNING! The user shall be liable for the consequences of an incorrect damage report or a contaminated pump. The statements in the damage report are legally binding. 6.3 Damage Report You find the form of the damage report to the Download on our web page in the menu "service" and "Downloads". If you should not have an entrance to the Internet, you can request the form also gladly with us, under phone WARNING! Incomplete or incorrectly completed damage reports may endanger the service personnel! Give full information in the damage report, in particular regarding a possible contaminating

17 Troubleshooting 7 Troubleshooting During the warranty period, intervention in the Diaphragm Pumps and accessory components may only be made by manufacturing firm. Trouble Cause by: Remedy with: Pump does not start No power supply Motor defective Qualified electrician Service workshop Check electrical installation Exchange Connected apparatus and/or connecting elements leaking Identify and seal the leak, replace the seals and/or hoses if necessary. Pump leaking Exchange the hoses and/or fittings if necessary. Pump does not generate a vacuum or overpressure Pump dirty Valve plate or diaphragm defective Valve plate dirty User or Service workshop General maintenance / Cleaning Exchange, see chapter Cleaning condensates and foreign objects out of the valves. Seals / diaphragms dirty Cleaning or exchange Loose screws Tighten the screws Separator container is full User Empty the separate container Pump dirty User or Service workshop General maintenance / Cleaning Running noise Valve plate, diaphragm, seals defective or dirty loose screws or connectors User Exchange or cleaning Tighten the screws and / or connectors Cable defective and/or brittle Qualified electrician Exchange of the cable

18 Spare Parts Overview 8 Spare Parts Overview The Spare parts- and Kit lists contain all the parts and all the information necessary for ordering. When ordering, please quote the description, quantity, serial number and order number! CAUTION! We are not liable for any damage caused by the installation of any parts not supplied by the manufacturer. 8.1 Kit Order numbers Diapragm pumps Models: 2019B C C-50 Diaphragm Pump head and Replacement Kit Rebuild Kit Foot Kit Order no. Order no. Order no. 2019K K K Diaphragm pump with vacuum regulator kit C-50 A B;C D E F G H;J Item Description Piece Order no. - Vacuum Regulator Kit, consisting of: A - Manometer 1/8 (mbar/kpa) brass 1 U B - Extension PP, G1/4 G1/ C - Reducing nipple PVDF, G 1/8 G ¼ D - Grub screw 1 U E - Regulator 1 U F - Regulator - Rotation upper part 1 U G - Hose nozzle PP, DN 6 G ¼ H - Plastic separator (38/69) 1 U J - Gasket washer FKM (40/30/3)

19 Spare Parts Overview 8.3 Spare parts view / Parts list Item Spare parts description 2019K K K-04 1 Diaphragm, Buna N PTFE Diapragm liner Diaphragm hold down plate Valve platte Assembly - * - 5 O-Ring Gasket, Head 1 * - 6 * Pump head includes item 4 and Haed screws Handle screws Diaphragm hold down plate screws Hose nozzle DN 8 PVDF 1/8 NPT x 1/4 ID Hose Rubber suction cup feet

Diaphragm pump 4 - headed

Diaphragm pump 4 - headed Operation Manual (EN) Translation of the german original manual Diaphragm pump 4 - headed Model: 67000062 412743-23 2016-10-17 Gardner Denver Thomas GmbH Am Vogelherd 20 98693 Ilmenau Germany T +49 3677

More information

Operation Manual. Diaphragm pumps 2-headed. Types MP 101 Zp, MP 201 Ep MPC 101 Zp, MPC 201 Ep

Operation Manual. Diaphragm pumps 2-headed. Types MP 101 Zp, MP 201 Ep MPC 101 Zp, MPC 201 Ep Operation Manual Diaphragm pumps 2-headed Types MP 101 Zp, MP 201 Ep MPC 101 Zp, MPC 201 Ep 400170 2007-11-16 We are constantly working on the further development of all our product types. Reprinting or

More information

Operation Manual. Diaphragm pumps. MP 054 Zp, MPC 054 Zp MP 104 Ep, MPC 104 Ep

Operation Manual. Diaphragm pumps. MP 054 Zp, MPC 054 Zp MP 104 Ep, MPC 104 Ep Operation Manual Diaphragm pumps Types MP 054 Zp, MPC 054 Zp MP 104 Ep, MPC 104 Ep 4000542 2008-03-20 We are constantly working on the further development of all our product types. Reprinting or reproduction

More information

MP 2401 E, MP 1801 Z, MP 1201 T

MP 2401 E, MP 1801 Z, MP 1201 T Operation Manual Diaphragm pumps 8-headed Types MP 2401 E, MP 1801 Z, MP 1201 T MPC 2401 E, MPC 1801 Z, MPC 1201 T 400152 2003-10-27 We are constantly working on the further development of all our product

More information

Operation Manual. Scroll pumps. Types scrollvac S 10 scrollvac S

Operation Manual. Scroll pumps. Types scrollvac S 10 scrollvac S Operation Manual Scroll pumps Types scrollvac S 10 scrollvac S 15 460004 2010-01-05 We are constantly working on the further development of all our product types. Reprinting or reproduction of this manual,

More information

Operation Manual. Scroll pumps. Dry Run II

Operation Manual. Scroll pumps. Dry Run II Operation Manual Scroll pumps Types Dry Run I Dry Run II 460002 2004-05-19 We are constantly working on the further development of all our product types. Reprinting or reproduction of this manual, including

More information

OWNER S MANUAL FOR DRY VACUUM PUMP MODEL: 2019

OWNER S MANUAL FOR DRY VACUUM PUMP MODEL: 2019 OWNER S MANUAL FOR DRY VACUUM PUMP MODEL: 2019 Model 2019B Model2019C Be sure to properly identify intake and exhaust before using the pump See Section 3.15 CAUTION Do not pump liquids with the pump. Pumping

More information

Original Operating Instructions V-VTE

Original Operating Instructions V-VTE Edition: 2.2.2012 BA 187-EN Original Operating Instructions V-VTE V-VTE 3 6 8 10 V-Serie V-Series Drehschieber Rotary Vane Table of contents Table of contents 1 Foreword...................................................................

More information

High Output Vacuum/Pressure Pump

High Output Vacuum/Pressure Pump High Output Vacuum/Pressure Pump User Guide Catalogue Numbers: WP62 115 60 (115 V, 60 Hz) WP62 220 50 (230 V, 50 Hz, 1.1 A) WP62 100 60 (100 V, 50/60 Hz) Notice The information in this document is subject

More information

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-08 Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose...

More information

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

User Manual GV25 GV35 GV702. Company information:   Original instructions GV12066 (1) User Manual Original instructions GV25 GV35 GV702 Company information: www.vipercleaning.eu info-eu@vipercleaning.com GV12066 (1) 2012-04-10 USER MANUAL ENGLISH TABLE OF CONTENTS Introduction... 4 Manual

More information

Rotary vane vacuum pumps Two-stage

Rotary vane vacuum pumps Two-stage Operation Manual (EN) Original version of the operation manual Rotary vane vacuum pumps Two-stage Models: Series CRVpro CRVpro 4 CRVpro 6 CRVpro 8 P1700011 2017-01-12 EMEA Gardner Denver Thomas GmbH Am

More information

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS! NEW APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS! www.welchvacuum.com/crvpro Discover the evolution of two-stage rotary vane vacuum pumps. Built to last. Born to perform. And designed to simplify your work.

More information

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P Contents Description Data Sheet No. Page Overview P-1.50.001E 117-118 Technical Data SFI-plus P-1.50.002E-1, 2 119-120 Dimensions

More information

Operating instructions

Operating instructions ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 793-0 Fax +49 (0) 793-0 info@de.ebmpapst.com www.ebmpapst.com CONTENTS. SAFETY REGULATIONS AND NOTES. Levels of hazard warnings.

More information

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: 79202-00 79202-05 79202-30 79202-35 Approval Agency s Model 79202-00 & 79202-05 Model 79202-30 & 79202-35 Not recommended for pumping acid,

More information

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS! NEW 4,6,8,16,24,30 APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS! www.welchvacuum.com/crvpro Discover the evolution of two-stage rotary vane vacuum pumps. Built to last. Born to perform. And designed to simplify

More information

USER MANUAL UN-200V / UN-200VH

USER MANUAL UN-200V / UN-200VH USER MANUAL UN-200V / UN-200VH CONTACT US PHONE/FAX Toll Free: 800.465.1004 Phone: 801.486.1004 Fax: 801.486.1007 ADDRESS LACO Technologies, Inc. 3085 West Directors Row Salt Lake City, UT 84104 WEB www.lacotech.com

More information

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515 OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515 Approval Agency s Model 2515B-75 Model 2515C-75 & 2515C-76 Warning Not recommended for pumping acid, base or organic vapors

More information

Original Operating Instructions V-VC

Original Operating Instructions V-VC Edition: 1.12.2009 BA 231-EN Original Operating Instructions V-VC V-VC 50 75 100 150 V-Serie V-Series Drehschieber Rotary Vane Table of contents Table of contents 1 Foreword...................................................................

More information

Laboport Chemically-resistant Laboratory Pumps and Systems

Laboport Chemically-resistant Laboratory Pumps and Systems Operating Instructions Read and observe these Operating Instructions! Laboport Chemically-resistant Laboratory Pumps and Systems N 810 FT.18 N 820 FT.18 N 840 FT.18 N 840.1.2 FT.18 N 810.3 FT.18 N 820.3

More information

Aluminum Heating Mantles

Aluminum Heating Mantles Aluminum Heating Mantles ON/OFF HOT User Guide Version 1.3 ON/OFF IEC power inlet socket Power supply switch (large-volume models). Power to either the lower part of the element or the upper and lower

More information

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar abs) Press. (bar g) (kg)

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar abs) Press. (bar g) (kg) MINI-DIAPHRAGM VACUUM PUMPS & COMPRESSORS N85, N85.3, N86 SECTION 41.23 N85.3KNI Concept The Mini-Diaphragm vacuum pumps from KNF are based on a simple principal - an elastic diaphragm, fixed on its edge,

More information

APPLIED VACUUM TECHNOLOGY VACUUM PUMPS & SYSTEMS

APPLIED VACUUM TECHNOLOGY VACUUM PUMPS & SYSTEMS APPLIED VACUUM TECHNOLOGY VACUUM PUMPS & SYSTEMS www.welchvacuum.com/crvpro Discover the evolution of two-stage rotary vane vacuum pumps. Built to last. Born to perform. And designed to simplify your work.

More information

Betriebsanleitung Operating Instructions

Betriebsanleitung Operating Instructions Betriebsanleitung Operating Instructions Oil mist filter idealvac.com (505)872-0037 idealvac.com ONF 16 PK 0213 BE/G (0811) ONF 25/25L/25XL Table of contents Table of contents 1 About this manual......................................

More information

Flameproof Manual Call Points

Flameproof Manual Call Points Operating instructions Additional languages www.r-stahl.com CS & Clifford & Snell Contents General Information.... Manufacturer.... Information regarding the operating instructions.... Further documents....

More information

BK 45 BK 45-U BK 45-LT BK 46

BK 45 BK 45-U BK 45-LT BK 46 Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-07 Contents Preface...3 Availability...3 Text layout...3 Safety...3 Usage for the intended purpose...3 Basic safety notes...4

More information

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions Operating Instructions Accessory Units Melitta Cafina XT Series Melitta Professional Coffee Solutions Contents General... 4. Manufacturer information... 4.2 About these instructions... 4.3 Explanation

More information

DIAPHRAGM PUMP OEM KNF /18 N TRANSLATION OF ORIGINAL OPERATING AND INSTALLATION INSTRUCTIONS ENGLISH

DIAPHRAGM PUMP OEM KNF /18 N TRANSLATION OF ORIGINAL OPERATING AND INSTALLATION INSTRUCTIONS ENGLISH KNF 308934-308937 09/18 OEM N 2400.15 TRANSLATION OF ORIGINAL OPERATING AND INSTALLATION INSTRUCTIONS ENGLISH DIAPHRAGM PUMP Note! Before operating the pump and the accessories, please read the operating

More information

MODEL 7000 SUCTION UNIT

MODEL 7000 SUCTION UNIT MODEL 7000 SUCTION UNIT OPERATOR S MANUAL Caution Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by the law of the State in which he practices

More information

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier Operating Manual Incl. EU Declaration of Conformity Vacuum Switch, Differential Pressure Adapter, Switching Amplifier VSC150, SV tina42e1-b (2017-03) 1 Product Identification In all communications with

More information

Dry, oilfree Diaphragm Pumps

Dry, oilfree Diaphragm Pumps Dry, oilfree Diaphragm Pumps Advantages analytically pure, oil free vacuum user friendly light weight, rugged design designed for permanent operation maintenance-free drive system and proven long diaphragm

More information

Airbrush Compressor & Vacuum Pump AS20W ARTICEL 34202

Airbrush Compressor & Vacuum Pump AS20W ARTICEL 34202 Operation Manual Airbrush Compressor & Vacuum Pump AS20W ARTICEL 34202 Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due

More information

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS NO RFEC/U/2017-1 (EN) (valid since 18.08.2017) ROOF FANS RF/EC...-... / RFV/EC...-... Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the

More information

Instruction Manual Suppository Penetration Tester. Type PM 30

Instruction Manual Suppository Penetration Tester. Type PM 30 Instruction Manual Suppository Penetration Tester Type PM 30 ERWEKA GmbH * Ottostr. 20 22 * 63150 Heusenstamm * Germany * Tel: +49 (0) 6104 6903-0 Fax: +49 (0) 6104 6903-40 * E-mail: info@erweka.com *

More information

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS NO RF/U/2017 (ENGLISH) (valid since 13.10.2017) ROOF FANS RF / RFV Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the right to modify this

More information

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Inspection Light LED Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3 Conformity

More information

ULTRA LOW TEMPERATURE FREEZER. User Manual

ULTRA LOW TEMPERATURE FREEZER. User Manual ULTRA LOW TEMPERATURE FREEZER User Manual Note:Kaltis reserves the right to modify any parts of this manual without prior notice. 1. No part of this manual may be reproduced in any form, or translated

More information

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC 2CKA001473B9007 19.05.2017 System Manual Busch-Infoline Handicapped toilet signal set 1510 UC-... -101 Table of contents Table of contents 1 Notes on the instruction manual... 3 2 Safety... 4 2.1 Information

More information

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111 OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111 Contents: Safety Information Installation Operation Maintenance Trouble-Shooting Guide Specifications Warranty Parts List and Exploded View

More information

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use! Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 74363 Güglingen Telefon +49 7135-102-0 Service +49 7135-102-211 Telefax +49 7135-102-147 info@afriso.de

More information

Original Operating Instructions C-VLR

Original Operating Instructions C-VLR Edition: 1.12.2009 BA 880/80-EN Original Operating Instructions C-VLR C-VLR 1000 C-Serie C-Series Klaue Claw Table of contents Table of contents 1 Foreword...................................................................

More information

ASPIRE Laboratory Aspirator

ASPIRE Laboratory Aspirator ASPIRE Laboratory Aspirator USER MANUAL Rev 2/14/18 Accuris Instruments / Benchmark Scientific Ph: (908) 769-5555 E-mail: info@accuris-usa.com (C) Benchmark Scientific, 2018 THE ACCURIS ASPIRE LABORATORY

More information

OPERATING MANUAL English Chemical Resistant Diaphragm Pump

OPERATING MANUAL English Chemical Resistant Diaphragm Pump OPERATING MANUAL English Chemical Resistant Diaphragm Pump C300 / C400/ C410 / C510/ C600 / C610 Room 303, Hall C, Office Building M8, No. 1 Jiuxianqiao East Road, Chaoyang District, Beijing 100015, China

More information

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL CONTENT 3 Introduction 3 General 3 Safety rules 3 Storage and transportation rules 3 Manufacturer s warranty 4 Fan design 4 Delivery set 5 Technical data

More information

USER S MANUAL ATH WH220

USER S MANUAL ATH WH220 USER S MANUAL ATH WH220 INDEX INTRODUCTION... - 3 - General information s... - 3 - Description of pneumatic jack... - 4 - Operation of jack... - 5 - Technical data... - 6 - Dimension drawing... - 6 - INSTALLATION...

More information

TTV 4500 / TTV 4500 HP / TTV 7000

TTV 4500 / TTV 4500 HP / TTV 7000 TTV 4500 / TTV 4500 HP / TTV 7000 EN OPERATING MANUAL AXIAL FAN TRT-BA-TTV4500-4500HP-7000-TC-003-EN Table of contents The current version of the operating manual can be found at: Notes regarding the operating

More information

3-way switching valve

3-way switching valve Operating Manual UK 3-way switching valve for domestic hot water charging USV 1" AG USV 5/4" AG USV 6/4" IG UK805189 / 201109 Translation of the original instruction manual Please read first This operating

More information

Installation and operating instructions. DK energy storage and DK energy buffer

Installation and operating instructions. DK energy storage and DK energy buffer Installation and operating instructions DK energy storage and DK energy buffer Edition: 08-2015 1 Preliminary note With this DK energy storage / DK energy buffer you purchased a DK quality product. The

More information

Vacuum Controller with Control Unit VC 900

Vacuum Controller with Control Unit VC 900 Operating Instructions Read and observe these operating instructions! Vacuum Controller with Control Unit VC 900 KNF Neuberger GmbH Alter Weg 3 79112 Freiburg Germany Tel. +49 (0)7664 / 5909-0 Fax +49

More information

Operating Instructions

Operating Instructions Translation of the original instructions Hena 200/300 Rotary Vane Pump Operating Instructions PD 0042 BEN/D (1108) EN Table of contents Table of contents 1 About this manual...............................................

More information

Ventilation and air conditioning QUALITY FOR LIFE. Refrigerating systems and heat pumps. Operating manual

Ventilation and air conditioning QUALITY FOR LIFE. Refrigerating systems and heat pumps. Operating manual Ventilation and air conditioning QUALITY FOR LIFE GB Refrigerating systems and heat pumps Operating manual Refrigerating systems and heat pumps 3052967 I 07/2010 Refrigerating systems and heat pumps Table

More information

Analog Melting Point Apparatus

Analog Melting Point Apparatus Analog Melting Point Apparatus User Guide Version 1.2 7. Turn off to begin cooling. A brass plug can be used if more rapid cooling is required. IEC power inlet socket (at rear) Magnifying lens Capillary

More information

Waste water ejection unit

Waste water ejection unit Waste water ejection unit Over ground box SWH 500/50-80 SWH 500/50-80 Operation manual Table of contents: Page Declaration of conformity... 3 1. General... 4 1.1 Introduction... 4 1.2 Enquiries and orders...

More information

VC-1, VC-1-SL, VC-2-L, VC-2-SL

VC-1, VC-1-SL, VC-2-L, VC-2-SL Pre-Cooling Unit Series VC VC-1, VC-1-SL, VC-2-L, VC-2-SL Instruction Manual Version 1.00.02 Dear customer, we have made up this operating manual in such a way that all necessary information about the

More information

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20-30-50-60-80-TC-001-EN Table of contents Information on the use of this manual... 1 Scope of delivery... 1 General safety...

More information

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59 SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery

More information

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45 GESTRA Steam Systems DK 45 EN English Installation Instructions 818676-00 Steam Trap DK 45 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED

More information

Operating Instructions

Operating Instructions Translation of the original instructions Hena 400/630 Rotary Vane Pump Operating Instructions PD 0043 BEN/D (1108) EN Table of contents Table of contents 1 About this manual...............................................

More information

Guide book ASPIMAX 32. Im Geer 20, Isselburg. Type No.: 403. Serial No.:...

Guide book ASPIMAX 32. Im Geer 20, Isselburg. Type No.: 403. Serial No.:... ASPIMAX 32 Manufacturer: deconta GmbH Im Geer 20, 46419 Isselburg Type No.: 403 Serial No.:... Index On page 1 Basic safety advices 3 2 Technical description 4 2.1 Operating mode separator Filter system

More information

Chemical resistant Vacuum Pumps

Chemical resistant Vacuum Pumps Chemical resistant Vacuum Pumps C300 / C400 / C410 / C510 / C600 / C610 English Operating Manual WIGGENS labortechnik GmbH Mühsamstrasse 3610249 Berlin Germany Fon:+49 30 42105470 Fax:+49 30 42105971 E-Mail:

More information

Dry, oilfree Diaphragm Pumps. Highlight NEW MPC 302 Z. 3 Diaphragm Pumps

Dry, oilfree Diaphragm Pumps. Highlight NEW MPC 302 Z. 3 Diaphragm Pumps Dry, oilfree Diaphragm Pumps Highlight NEW MPC 302 Z MPC 601 T 412743 Advantages analytically pure, oil free vacuum user friendly light weight, rugged design designed for permanent operation maintenance-free

More information

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A) EN Installation manual surface mounting plugs and socket outlets, panel 60003214 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3

More information

SILENT compact /

SILENT compact / SILT compact 2934 0000 / 2934 1000 TRANSLATION OF THE ORIGINAL INSTRUCTIONS FOR USE Made in Germany Ideas for dental technology 21-2245 21052015 / A Contents 1. Introduction...3 1.1 Symbols...3 2. Safety...3

More information

Operating instructions

Operating instructions Operating instructions (Translation of the original operating instructions) Type TEKA FILTERCUBE-MV TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen

More information

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting EN Installation manual extra-low-voltage socket outlets for panel- and 60003221 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal

More information

Oil-Sealed Rotary Vane Pumps

Oil-Sealed Rotary Vane Pumps Oil-Sealed Rotary Vane Pumps P 4 Z 322002 Advantages high water vapour tolerance for chemical applications compact, robust and functional construction low noise emission no oil contamination of the chamber

More information

Original Operating Instructions V-VTR

Original Operating Instructions V-VTR Edition: 1.12.2009 BA 261-En Original Operating Instructions V-VTR V-VTR 100 140 V-Serie V-Series Drehschieber Rotary Vane Table of contents Table of contents 1 Foreword...................................................................

More information

Operation Manual Airbrush Compressor AH28A ARTICLE 34247

Operation Manual Airbrush Compressor AH28A ARTICLE 34247 Operation Manual Airbrush Compressor AH28A ARTICLE 34247 Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further developments,

More information

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN TTK 75 ECO EN OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN Table of contents Notes regarding the operating manual... 01 Information about the device... 02 Safety... 04 Transport...05 Start-up...05

More information

INSTRUCTIONS CertoClav EL

INSTRUCTIONS CertoClav EL High Pressure-LABORATORY AUTOCLAVE Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization As an aid in research and development Thermometer Lid handle with locking

More information

Karlsruher Glastechnisches Werk KGW-ISOTHERM

Karlsruher Glastechnisches Werk KGW-ISOTHERM Karlsruher Glastechnisches Werk KGW-ISOTHERM Germany 76185 Karlsruhe Gablonzer Straße 6 Tel. 0049 / 721 / 95897-0 Fax. 0049 / 721 / 95897-77 E-Mail: info@kgw-isotherm.de Internet: kgw-isotherm.com Operating

More information

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100 1 Safety instructions Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead

More information

Operating Instructions

Operating Instructions WD 3 Premium Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. English 5 59658050 (08/15) 10 11 12 13 14 15 16 2 3 4 Contents General

More information

OWNER S MANUAL FOR DRY VACUUM PUMP MODEL: 2581

OWNER S MANUAL FOR DRY VACUUM PUMP MODEL: 2581 OWNER S MANUAL FOR DRY VACUUM PUMP MODEL: 2581 Warning Not recommended for pumping acid, base or organic vapors or gases. Warning Be sure to properly identify intake and discharge before using pump. See

More information

AIR COMPRESSOR TC UTC TC UTC125502

AIR COMPRESSOR TC UTC TC UTC125502 AIR COMPRESSOR TC120242 UTC120242 TC125502 UTC125502 Warning! When using compressors, basic safety precautions should always be followed to reduce the risk of fire, electric shock and personal injury.

More information

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

Manual v1 Page 1 of 19. Manual. Laboratory autoclave Manual 20.2.2015 v1 Page 1 of 19 Manual Laboratory autoclave Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization, as an aid in research and development CertoClav

More information

Operating Manual. VIENNA Hot Display

Operating Manual. VIENNA Hot Display Operating Manual VIENNA Hot Display Operating and Maintenance instructions Please read this manual carefully before you start to operate your heated display case. Following these instructions helps you

More information

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN TTV 1500 / TTV 3000 EN OPERATING MANUAL CONVEYING FAN TRT-BA-TTV1500-3000-TC2016-26-004-EN Table of contents Notes regarding the operating manual... 2 You can download the current version of the operating

More information

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278 Illustration shows item no Z-3278 Operating manual BlueMobil eco Item no: Z-3278 Original operating manual Important Copyright It is essential that you read this manual thoroughly before the initial operation

More information

Industrial Vacuums, Inc

Industrial Vacuums, Inc Instructions/Spare Parts Manual Nilfisk Model GWD255 Drum Top Vacuum CAUTION: This Nilfisk vacuum cleaner is not to be used in explosion-hazardous areas, as serious injury could result. Under no circumstances

More information

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1 Specifications Rated voltage (V) AC 110-120V or 220-240V / 50-60Hz Vacuum motor power consumption(w/hp) 1200 / 1.6 Exhaust water pump power consumption(w/hp 800 / 1.1 Exhaust water pump flow (GPH/LPH)

More information

Manual Power relay SR853

Manual Power relay SR853 Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death

More information

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS: / / / 2047

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS: / / / 2047 OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS: 2014 2032 / 2042 2034 / 2044 2037 / 2047 Agency: Be sure to properly identify intake and exhaust before using the pump. See Section 2.15 CAUTION Do not pump

More information

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc User manual Explosion-safe window air conditioning system Type series AR-054 II 3 G Ex ic nac h IIC T3 Gc 1. Safety Instructions The window air conditioning series AR-054 is an explosion-safe product suitable

More information

Original Operating Instructions V-VCA / V-VCE

Original Operating Instructions V-VCA / V-VCE Edition: 1.12.2009 BA 150/3-EN Original Operating Instructions V-VCA / V-VCE V-VCA 25 40 V-VCE 25 40 V-Serie V-Series Drehschieber Rotary Vane Table of contents Table of contents 1 Foreword...................................................................

More information

TFV 900 OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN

TFV 900 OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN TFV 900 EN OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN Table of contents Notes regarding the operating manual... 1 Safety... 2 Information about the device... 3 Transport and storage... 4 Start-up...

More information

Aquamax KF Oil Evaporator. User Manual

Aquamax KF Oil Evaporator. User Manual Aquamax KF Oil Evaporator User Manual Edition 1.1 - April 2015 Contents Chapter 1 Introduction... 2 1.1 Instrument Description... 2 1.2 Principle of Measurement... 2 1.3 Instrument Connections... 2 Chapter

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS: 2014 / 2032 / 2042 / 2034 / 2044 / 2037 / 2047

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS: 2014 / 2032 / 2042 / 2034 / 2044 / 2037 / 2047 OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS: 2014 / 2032 / 2042 / 2034 / 2044 / 2037 / 2047 Be sure to properly identify intake and exhaust before using the pump. See Section 2.15 CAUTION Do not pump liquids

More information

MV 4 MV 4 Premium. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

MV 4 MV 4 Premium. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them. MV 4 MV 4 Premium Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. www.kaercher.com/register-and-win 59651790 10/13 3 4 2 5 6 7 1 8

More information

Chemistry diaphragm pumps

Chemistry diaphragm pumps Oil-free vacuum for corrosive gases and vapors Chemistry diaphragm pumps Series overview Examples of use Down to 70 Pumping of aggressive gases and vapors For low-boiling solvents Vacuum filtration Down

More information

AC6/6H & AC8/8H Horizontal Metric Models

AC6/6H & AC8/8H Horizontal Metric Models AC6/6H & AC8/8H Horizontal Metric Models ASSEMBLY, INSTALLATION AND OPERATION MANUAL Part No. 108203 EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully

More information

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200 Series FCU1x00 Installation instructions and operating manual Sauna control system FCU1000 / FCU1200 only sauna FCU1000 additional humidity FCU1200 Doc-ID: B_M_FCU1xxx-A5_EN Version: V 1.06 certificated

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...

More information

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A Millo / Millo pro Nr. 1804-x000 / 1805-x000 0609 21-6543 A Ideen für die Dentaltechnik 1 2 3 4 5 6 7 8 9 10 11 12 Millo / Millo pro No. 1804-x000 / 1805-x000 ENGLISH Content Introduction... 15 Symbols...

More information

235L G. Original-Gebrauchsanleitung V1/1115

235L G. Original-Gebrauchsanleitung V1/1115 235L 700335G Original-Gebrauchsanleitung V1/1115 GB/UK ENGLISH Table of contents 1.Safety... 20 1.1 Safety instructions... 20 1.2 Key to symbols... 23 1.3 Proper use... 24 2. General information... 25

More information

Test Unit GTL 100 for Fire Detectors

Test Unit GTL 100 for Fire Detectors Test Unit GTL 100 for Fire Detectors Description and Operation Manual Zertifiziertes QM System Nach DIN EN ISO 9001 Description and Operation Manual Table of Contents 1. Instructions 1.1 General 1.2 Standards

More information

Part No KEMPER Filter-Master XL

Part No KEMPER Filter-Master XL Part No. 150 0492 KEMPER Filter-Master XL 1. Application and Mode of Operation.... 2 2. Safety Instructions......... 2 3. Placing into Operation...... 3 4. Operation Elements and Function... 3-4 5. Installation

More information

MANUAL Oil Level Sensor

MANUAL Oil Level Sensor PROCESS AUTOMATION MANUAL Oil Level Sensor KVF-104-PF ISO9001 0102 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products

More information