Conditioning Hoppers. Installation and Electrical Wiring Guide
|
|
- Avice Hunter
- 5 years ago
- Views:
Transcription
1 Conditioning Hoppers Installation and Electrical Wiring Guide
2 PAGE -1 of 24 CONDITIONING HOPPER
3 We appreciate your business and hope you enjoy your Samuel Jackson Seed Cotton Conditioning Hopper This manual contains basic information on the installation of your Seed Cotton Conditioning Hopper. Additional information for the moist air pipe sizing, pipe routing, and fan requirements is usually supplied directly to the gin as each installation is unique. In the future when you require service, technical support, or parts please contact us by phone, fax, or the internet. Our engineers and service people are available to assist you in obtaining the best performance from your Samuel Jackson, Inc. products. Again, thanks for choosing a Samuel Jackson Seed Cotton Conditioning Hopper SAMUEL JACKSON, INCORPORATED MAIL: P.O. BOX LUBBOCK, TEXAS COURIER: 3900 UPLAND AVENUE LUBBOCK, TEXAS TELEPHONE OR TELEFAX engineering@samjackson.com Internet: Copyright 2004 SAMUEL JACKSON, INCORPORATED. All rights reserved. PAGE 0 of 24 CONDITIONING HOPPER
4 CLASSIC STYLE CONDITIONING HOPPER DIMENSIONS & PARTS Hoppers are custom made to fit into the space of the existing gin stand feeder hopper. The overall height, width and depth varies from installation to installation. A typical CLASSIC STYLE side double entry hopper is shown below. The following drawings are to be used for typical dimensions and views for Double Entry and Single Entry Hoppers. Consult factory for recommended layout for moist air piping Humid Air Valve (One for single entry, two for double entry) Valve in open position. Note roll pin indicator position. Roll pin valve position indicator Valve in closed position Inlet Transition 7 inch dia to 3 X 14, 12 inch overall length (One supplied for single entry, two for double entry) PAGE 1 of 24 CONDITIONING HOPPER
5 PAGE 2 of 24 CONDITIONING HOPPER
6 PAGE 3 of 24 CONDITIONING HOPPER
7 END ENTRY STYLE DOUBLE AIR ENTRY CONDITIONING HOPPER The End Entry Style Double Entry Conditioning Hopper is shown below. Humid air enters the valves located on the ends of the Hopper requiring only one manifold pipe to connect multiple hoppers. Consult factory for recommended layout of air piping. Hoppers are custom made to fit into the space of the existing gin stand feeder hopper. The overall height, width and depth varies from installation to installation. A drawing showing typical dimensions and the dimensions required for construction is shown on next page Humid Air Valve with Transition PAGE 4 of 24 CONDITIONING HOPPER
8 PAGE 5 of 24 CONDITIONING HOPPER
9 PARTS FOR THE CONDITIONING HOPPERS A Plant Installation Package is included with the hopper order. It includes a or Valve Relay Panel, a Relief Plug and a Air Filter, Regulator, Lubricator Assembly. The Valve Relay Panel is used with all Samuel Jackson Humidaire Units except the HU oil-fired Humidaire Unit. Use the panel for the 1260 model. Refer to the section on electrical schematics for the wiring to match your model Humidaire Unit Valve Relay Panel Valve Relay Panel (Note 5th relay required for use with the HU model Humidaire Unit) Air Filter, Regulator and Lubricator Assembly One Assembly supplies air to all hoppers in the system. Adjust regulator to about 80 psi pressure. PAGE 6 of 24 CONDITIONING HOPPER
10 INSTALLATION OF RELIEF PLUG ASSEMBLY The purpose of the Relief Plug is to allow a constant flow of air through the Humidaire Unit regardless of whether the hopper(s) are calling for air. The weights are adjusted on the plug so that no air is relieved when all hoppers are calling for air and all air is relieved when no hoppers are calling for air. On the following page is a drawing showing the typical installation of the Relief Plug. Consult the factory for more information on its installation or to the sheet metal installation drawings supplied with the piping. Removable stack weights PAGE 7 of 24 CONDITIONING HOPPER
11 PAGE 8 of 24 CONDITIONING HOPPER
12 HOOK-UP OF HUMID AIR VALVE A decal is located near the air solenoid valve to help identify the valve ports. Compressed air of 80 psi (5.5 bars) is sufficient to operate the valve. This air should come from the Filter, Regulator and Lubricator Assembly. The solenoid valve coil is always volt, 50 or 60 HZ. Its power comes from the Humidaire Unit. Moist air butterfly valve is closed when coil is energized. EXHAUST EXH P B A AIR INLET 80 PSI (5.5 BAR) AIR VALVE & CYLINDER HOOKUP Air hook-up detail decal Air Cylinder Coil for valve 110V-50HZ, 120V-60HZ Solenoid Valve Humid Air Valve PAGE 9 of 24 CONDITIONING HOPPER
13 CONTROL LOGIC FOR HUMID AIR VALVES The butterfly valve in the Humid Air Valve should close the moist air flow off to the hopper when cotton is not flowing through the hopper. It is most common for the 240 VAC or 110 VAC signal to the Valve Relay Panel terminals 1,2, 3 and 4 (corresponding to each gin stand) to come from the gin stand breast in limit switch. Sometimes, the signal comes from the gin stand feeder feed works control. Terminal 9 is the common terminal for the signal input. A13850 or Relay Panel controls the action of the solenoid valves on the Humid Air Valves and the water pump run signal to the Humidaire Unit. If no hoppers are calling for cotton, the water pump run signal is off. As soon as one hopper calls for cotton, a water pump run signal is given. The solenoid valve coils on the Humid Air Valves are always VAC. Their power comes from the Humidaire Unit. SJI Part No Relays should be used for 120 VAC inputs. SJI Part No Relays should be used for 240 VAC inputs. PAGE 10 of 24 CONDITIONING HOPPER
14 FOLLOWING IS ELECTRICAL WIRING SCHEMATIC FOR VALVE RELAY PANEL FOR SINGLE AND DOUBLE ENTRY CONDITIONING HOPPERS USED WITH SAMUEL JACKSON HUMIDAIRE UNIT MODELS: HU GAS-FIRED HU-SOUTHWEST-1480 GAS-FIRED PAGE 11 of 24 CONDITIONING HOPPER
15 PAGE 12 of 24 CONDITIONING HOPPER
16 FOLLOWING ARE ELECTRICAL WIRING SCHEMATICS FOR VALVE RELAY PANEL FOR SINGLE AND DOUBLE ENTRY CONDITIONING HOPPERS USED WITH SAMUEL JACKSON HUMIDAIRE UNIT MODELS: HU GAS-FIRED HU OIL-FIRED PAGE 13 of 24 CONDITIONING HOPPER
17 PAGE 14 of 24 CONDITIONING HOPPER
18 PAGE 15 of 24 CONDITIONING HOPPER
19 FOLLOWING ARE ELECTRICAL WIRING SCHEMATICS FOR VALVE RELAY PANEL FOR SINGLE AND DOUBLE ENTRY CONDITIONING HOPPERS USED WITH SAMUEL JACKSON HUMIDAIRE UNIT MODELS: HU C GAS-FIRED HU OIL-FIRED HU GAS-FIRED PAGE 16 of 24 CONDITIONING HOPPER
20 PAGE 17 of 24 CONDITIONING HOPPER
21 PAGE 18 of 24 CONDITIONING HOPPER
22 FOLLOWING ARE ELECTRICAL WIRING SCHEMATICS FOR VALVE RELAY PANEL FOR SINGLE AND DOUBLE ENTRY CONDITIONING HOPPERS USED WITH SAMUEL JACKSON HUMIDAIRE UNIT MODELS: HU OIL-FIRED PAGE 19 of 24 CONDITIONING HOPPER
23 PAGE 20 of 24 CONDITIONING HOPPER
24 PAGE 21 of 24 CONDITIONING HOPPER
25 PAGE 22 of 24 CONDITIONING HOPPER
26 IMPORTANT! The following notice affects your warranty. Electrical Controls and Your Safety Your new Sam Jackson product may be equipped with electrical controls, or designed to interact with controls on a related Sam Jackson product. In the event that local, state, federal or other specified safety compliance is required, we will consider modifications to meet the particular requirements. Implementation of alternative safety devices may incur additional charges. No warranty of compliance with a particular standard is made in the absence of specific reference to it in our quotation. If you modify, or permit others to modify, these controls without specific written permission from Sam Jackson, Inc. the warranty on your product will be void and there is a possibility of serious damage to machinery, damage to product, serious injury to personnel, or death. The modifier of the controls assumes all liability for these consequences. Samuel Jackson, Incorporated 3900 Upland Avenue Lubbock, Texas PAGE 23 of 24 CONDITIONING HOPPER
27 This page intentionally blank
HG Million Btu/Hr Gas-Fired Heater
HG-1-1142 1-Million Btu/Hr Gas-Fired Heater PAGE -2 of 30 HG-1-1142 GAS-FIRED HEATER Table of Contents Warnings... 1-2 Specifications... 3 Preliminary Checks Prior to Initial Operation... 4 Adjusting the
More informationOPERATING MANUAL MODEL AIR 1500TM AIR DRYER
OPERATING MANUAL MODEL AIR 500TM AIR DRYER Puregas, LLC 226-A Commerce St. Tel: 800-52-535 Broomfield, Colorado Fax: 303-657-2205 P/N P0255 REV A, 02/9/4 TABLE OF CONTENTS.0 GENERAL... 3 2.0 SPECIFICATIONS...
More informationSERVICE MANUAL STEAMROLLER LINT CONDITIONER (MODELS SR & SR )
SERVICE MANUAL STEAMROLLER LINT CONDITIONER (MODELS SR-2000-54 & SR-2000-40) Typical Steamroller Lint Conditioner TABLE OF CONTENTS Introduction...1 How Does the Steamroller Work?...2 STARTUP and ADJUSTMENTS...3
More informationMODEL MW200 MODEL MW600 AIR DRYER
OPERATING MANUAL MODEL MW200 MODEL MW600 AIR DRYER Mail Address: 226A Commerce St. Tel: 303-465-3063 Broomfield, CO 80020 Fax: 303-465-9294 TABLE OF CONTENTS 1.0 GENERAL...3 2.0 SPECIFICATIONS...3 3.0
More informationDEMA 832 LAUNDRY MASTER TM INSTALLATION INSTRUCTIONS
System Overview DEMA 832 LAUNDRY MASTER TM INSTALLATION INSTRUCTIONS The DEMA 832 Laundry Master is designed for long reliable use with simplicity in mind for both the installer and user. The system is
More informationDEMA 830 Laundry Master TM Installation Instructions
I-656 Pg. 1 of 9 SYSTEM OVERVIEW The DEMA 830 Laundry Master is designed for long reliable use with simplicity in mind for both the installer and user. The system is based on the reliable DEMA peristaltic
More informationAlways keep this manual in a safe readily accessible location. MODEL SERIAL SERVICE COMPANY TELEPHONE NUMBER
Always keep this manual in a safe readily accessible location. MODEL SERIAL SERVICE COMPANY TELEPHONE NUMBER For Operating Instructions or Technical Support Call 1-507-886-6666 Last Revision: 1/31/12 Starting
More informationDEMA SOLID PRODUCT LAUNDRY MASTER TM MODEL: 581L-1W and 581L-2W INSTALLATION INSTRUCTIONS
Included Parts: A. 581.1 Solid Bowl B. 58.1LA Vacuum Breaker C. 58.6 Stainless Steel Supply Tube D. 58.29 90º Compression Fitting E. 58.24 Straight Compression Fitting F. 58.7 Vinyl Discharge Tube G. 66.123
More informationCotton Humidification Systems. from Samuel Jackson, Incorporated. Copyright 2002 SAMUEL JACKSON, INCORPORATED. All rights reserved
Cotton Humidification Systems from Samuel Jackson, Incorporated Copyright 2002. All rights reserved A BRIEF WORD ABOUT OUR COMPANY... Samuel Jackson s Lubbock, Texas Factory and Offices Cotton conditioning
More informationRetrofit Instructions for Tower Dryer Moisture Sampler Blower Kit
Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit Installation Manual PNEG-1982 Date: 03-26-15 PNEG-1982 2 PNEG-1982 Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit Table
More informationDRI-AIR INDUSTRIES HOPPER BANK OPERATING MANUAL
HOPPER BANK OPERATING MANUAL Page 1 DRI-AIR INDUSTRIES, INC. 16 THOMPSON ROAD P.O. BOX 1020 EAST WINDSOR, CT 06088-1020 Tel. (860) 627-5110 FAX (860) 623-4477 Internet http://www.dri-air.com e-mail: sales@dri-air.com
More information3. What are the main parts in a compressed air generation? And list the flow path in order? 4. Draw the ISO symbol for an air compressor.
Prep work in class for Module 2 1. What is the main function of an air generation and distribution? 2. How does an air generation work? 3. What are the main parts in a compressed air generation? And list
More informationFlopurge TS. Operation Manual
Flopurge TS Operation Manual Part Number 079-0204 Spectron Gas Control Systems United Kingdom Unit 4, Herald Court, University of Warwick Science Park, Coventry, CV4 7EZ +44 (0)24 7641 6234 sales@spectron-gcs.com
More informationInstallation Manual CARBONATOR With Plain-Water Booster
CORNELIUS INC One Cornelius Place Anoka, MN 55303-6234 Telephone (800) 238-3600 Facsimile (763) 422-3246 Installation Manual CARBONATOR With Plain-Water Booster IMPORTANT: It is the responsibility of the
More informationSCD. SMALL CYLINDER DRYER with Touchscreen Controller INSTRUCTION MANUAL MANUAL NUMBER Issued March 2015
SCD SMALL CYLINDER DRYER with Touchscreen Controller INSTRUCTION MANUAL MANUAL NUMBER 21-11-1042 Issued March 2015 Copyright 2015, Galiso, Inc. 22 Ponderosa Ct., Montrose, CO 81401 (970) 249-0233 (800)
More informationDFG-100 XCEL SERIES GAS CONVECTION OVEN REPLACEMENT PARTS LIST
DFG-00 XCEL SERIES GAS CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE JANUARY, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified
More informationECO1ZN3P, ECO2ZN4P ECO
WARNING HOT This product may have hot fluid circulating through it. DO NOT TOUCH! SOME UNION NUTS MAY BECOME LOOSE AND CONSEQUENTLY LEAK THROUGH TRANSPORTATION VIBRATION AND HANDLING. DO NOT OVERTIGHTEN
More informationHU King Mesa Gas-Fired Humidaire Unit
HU-80-1635 King Mesa Gas-Fired Humidaire Unit PAGE 1 of 91 HU-80-1635 KING MESA GAS-FIRED HUMIDAIRE UNIT Table of Contents Warning!... 5 HU-80-1635 King Mesa Humidaire Unit Specifications... 6 What s new
More informationTelecab Residential Elevator OWNER S MANUAL
Telecab Residential Elevator OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000627 03-m06-2011 2 IMPORTANT Ensure that only an authorized Savaria Dealer
More informationDEMA 844 Laundry Master Laundry Chemical Dispensing
DEMA 844 Laundry Master Laundry Chemical Dispensing Overview The DEMA Laundry Master is a digital laundry dispenser designed to dispense chemicals when signals are received from commercial laundry machines.
More informationINSTRUCTIONS FOR TAL SERIES VACUUM HOPPER LOADER
INSTRUCTIONS FOR TAL SERIES VACUUM HOR LOADER TAL-15U 150 LBS PER HOUR MAGNETIC LEVEL SWITCH TAL-3U-E 450 LBS PER HOUR SIGHT GLASS WITH PROXIMITY LEVEL SWITCH Proportional Dual Feed Valve Available TAL-6U
More informationINTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION
INSTALLATION AND OPERATING INSTRUCTIONS FOR THE HARDY Fuel Oil Furnace Models D-140 & D-350 HARDY MANUFACTURING COMPANY, INC. 12345 ROAD 505 PHILADELPHIA, MS 39350 PHONE: (601) 656-5866 FAX: (601) 656-4559
More information! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-315(C)
Models 51, 51-S and 53 Boiler Water Feeders Models 51-2, 51-S-2 and 53-2 Feeder Cut-Off Combinations McDonnell & Miller Installation & Maintenance Instructions MM-315(C) OPERATION Maximum Water Supply
More informationTelecab17 Residential Elevator OWNER S MANUAL
Telecab17 Residential Elevator OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 001081 30-m06-2017 2 IMPORTANT Ensure that only an authorized Savaria Dealer
More informationARM SERIES Switching Relays With Priority
Models ARM-2P ARM-3P ARM-4P ARM-6P AD-1 AD-4 ARM SERIES Switching Relays With Priority INSTALLATION, OPERATION & MAINTENANCE MANUAL ARM-2P ARM-4P AD-1 ARM-3P ARM-6P AD-4 Information and specifications
More informationInstallation Instructions
50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,
More informationInstallation Instructions
50ES---A, 50EZ---A, 50VL---A, 50VG---A, 50VR---A, 50VT---A, 604D--- ---A, 607C--- ---A, 607E,--- ---A, 704D--- ---A, 707C--- ---A, 707E--- ---A PA3G --- --- A, PH3G --- --- A SMALL PACKAGED PRODUCTS Electric
More informationFlostop TS D7E and A8E. Operation Manual
Flostop TS D7E and A8E Operation Manual United Kingdom Spectron Gas Control Systems Ltd, Unit 4, ATU1, University of Warwick science Park, Coventry, +44 (0) 24 7641 6234 sales@spectron-gcs.com Germany
More informationDEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS
DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS Models: DM-813-PLLL-1T DM-813-PDLL-1T DM-813-PLLL-2T DM-813-PDLL-2T I-729 Pg 1 of 15 System Overview The DEMA DEMAMaster probeless series is designed
More informationDRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)
DRY AIR SYSTEMS, INC. 2655 Metro Boulevard Maryland Heights, Missouri 63043 (314) 344-1114 fax (314) 344-0677 HD SERIES DRIERS TABLE OF CONTENTS WHY AN AIR DRYER 3 WHAT IS A DESICCANT AIR DRYER 3 Desiccant
More informationMonitored Pneumatic Valves On Series Ported Manifold
Monitored Pneumatic Valves On Series Ported Manifold Patented Technology SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per EN 954-1 & AS4024.1 SIL 3 as per IEC 61508 Applications Include: Pneumatic Presses
More informationEnergy management function at adsorption dryer PDAD
Application note Energy management function at adsorption dryer PDAD Application note for use of the energy management function at adsorption dryer PDAD. Explanation, use and layout of purge air regulation
More informationBulletin , March Electric Hot Gas Bypass Valves
Bulletin 100-60, March 2018 Electric Hot Gas Bypass Valves PAGE 2 / Bulletin 100-60 10 FEATURES AND BENEFITS SDR-4 Direct temperature control Tight shutoff when closed Can be interfaced with direct digital
More informationMultilift Vertical Platform Lift OWNER S MANUAL
Multilift Vertical Platform Lift OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000609 02-m06-2016 2 IMPORTANT Ensure that only an authorized Savaria
More informationDFG-100 XCEL SERIES GAS CONVECTION OVEN REPLACEMENT PARTS LIST
DFG-00 XCEL SERIES GAS CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE MARCH 00 BLODGETT OVEN COMPANY, Lakeside Avenue, Burlington, Vermont 00 USA Telephone: (0) 0-00 (00) - Fax: (0) 0- www.blodgett.com
More informationNovember 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES
November 2006 / BULLETIN -60 ELECTRIC DISCHARGE BYPASS VALVES PAGE 2 / Bulletin -60 10 FEATURES AND BENEFITS Direct temperature control Tight shutoff when closed Can be interfaced with direct digital controls
More information½ Monitored Pneumatic Valves On Series Ported Manifold
½ Monitored Pneumatic Valves On Series Ported Manifold Patented Technology SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per AS4024.1-Part 1502 & 1502 SIL 3 as per IEC 61508 & EN ISO 13849-1 Applications
More informationYOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.
Temperature Control Units Water & Oil 0-00 F Portable Chillers 0 - F Central Chillers Packages & Modules 0 - F Pump Tank Stations Chilled or Tower Water 00-0 gallons Cooling Tower Cells 4-40 tons Filters
More informationSeries 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING
Series 47 and 247 Mechanical Water Feeders McDonnell & Miller Installation & Maintenance Instructions MM-316(C) Series 47-2 and 247-2 Combination Mechanical Water Feeder/Low Water Cut-Off Series 47 Water
More informationHumidistat-Thermostat
Humidistat-Thermostat Model # HF _- - - Owner s Manual PNEG-236 Date: 12-02-09 PNEG-236 2 PNEG-236 Humidistat-Thermostat Table of Contents Contents Chapter 1 Safety... 4 Safety Guidelines... 4 Humidistat-Thermostat
More informationRing Detect Relays. Model RDR. Installation & Operation. Ph: \ \
Ring Detect Relays Installation & Operation P005116 Rev. E 180803 8/3/2018 11:19 AM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com Table of Contents Package Contents... 2 Models
More informationCleanSpray System Operation
Nordson Corporation OPERATOR S CARD P/N 108684C CleanSpray System Operation Introduction The individual manuals for the CleanSpray Gun, CleanSpray Controller and Model 25B Pump are included with each component.
More informationElectrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with K-style cordsets.
Electrical System 11-1 Section 11 Electrical System NOTE: This section applies to applicators with K-style cordsets. Table of Contents Electrical System........................................... 11-1
More informationIndustrial Refrigeration Defrost Solutions TM Package. Brochure R-222
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Industrial Refrigeration Defrost Solutions TM Package Brochure R- R-
More informationPC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]
PC SERIES 50 Hertz Self-Contained Packaged Air Conditioners 4 and 5 Ton [14.1 kw to 17.6 kw] Nominal Cooling Capacity: 48,000 to 60,000 BTUH The PC 50 Hz self-contained packaged air conditioners are designed
More informationRing Detect Relays. Model RDR. Installation & Operation. Ph: \ \
Ring Detect Relays Installation & Operation P005116 Rev. D 141020 10/20/2014 11:25 AM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com Table of Contents Package Contents...2
More informationInstallation Instructions
Electric Heaters 5 --- 20 kw Installation Instructions SMALL PACKAGED PRODUCTS 2to5Tons Accessory Electric Heaters (Single---Point Connection) NOTE: Read the entire instruction manual before starting the
More informationMODEL Vertical-Lift, 60, DC Power Lift, Manual Tilt
Contents Page Receiving Procedures.................... 1 Warranty............................. 1 Safety Information..................... 1-2 Machine Description................... 3-4 Operating Instructions....................
More informationInstallation Instructions
EHNA Electric Heaters 5-20kW For 60 Hz Small Packaged Products MODELS: PAD3, PHD3, PAD4, PHD4, PAD5, PHD5, WPA3, WPH3 Installation Instructions NOTE: Read the entire instruction manual before starting
More informationWKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--
8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe
More informationTG-10 Wall Mount Installation and Operation Manual. High Output Ozone Generator
TG-10 Wall Mount Installation and Operation Manual High Output Ozone Generator Ozone Solutions 451 Black Forest Road Hull, IA 51239 Phone: (712) 439-6889 Fax: (712) 439-6733 2 Table of Contents Safety
More information1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR
1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR IMPORTANT: Please read these installation and operating instructions completely and carefully before
More informationEEMAX ProAdvantage Series 1
EEMAX ProAdvantage Series 1 ELECTRIC INSTANTANEOUS WATER HEATER INSTALLATION GUIDE AND OWNER S MANUAL MODELS COVERED: PA004120T 1Φ 120V PA008208T 1Φ 208V PA005240T 1Φ 240V PA007240T 1Φ 240V PA010240T 1Φ
More information! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION
Series 61 Low Water Cut-Off Typical Applications: - Primary or secondary low water cut-off for hot water and steam boilers. - Low water cut-off - High water cut-off - Alarm actuator OPERATION Maximum Boiler
More informationOPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4
GB OPERATING MANUAL ORWAK 3400 March 2005 PUBL. NO 4869057-00 Edition 4 English TABLE OF CONTENTS Safety... 82 Operating instructions... 93 Technical specifications. 104 Dimensional drawing... 104 Transport...
More informationME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS
ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS M24E M36E Telephone: (802) 658-6600 Fax: (802)864-0183 www.marketforge.com PN 14-0309 Rev G (11/17) 2017 - Market Forge
More informationWIRING MODEL 20 Low Water Cut-Off and Pump Control MAXIMUM PRESSURE: 20 PSI INTERNAL WIRING BLUE WHITE UPPER PROBE (FEED OFF) FEED PROBE (FEED ON) ALL
No moving parts to stick, wear or hang-up. 20 Series Pump Control Low Water Cut-Off Combination 120 VAC Operating Voltage Max. Pressure 20 psi LISTED No replacement or rebuilding of floats or mechanical
More information1022 R/T Remote Monitor
1022 R/T Remote Monitor INSTRUCTIONS AMC-1022R/T WITH REMOTE SENSOR OR TRANSMITTER INSTALLATION AND OPERATING INSTRUCTIONS FOR THE AMC-1022R/T UNIT IMPORTANT: Please read these installation and operating
More informationSTARBUCKS UC100 PROGATE
STARBUCKS UC100 PROGATE Operator s Manual Release Date: January 24, 2008 Publication Number: 621054211OPR Revision Date: April 07, 2014 Revision: B Visit the Cornelius web site at www.cornelius.com for
More informationRPI Industries, Inc.
IMPORTANT: THE FOLLOWING INFORMATION SHOULD BE RETAINED FOR FUTURE REFERENCE RPI Industries, Inc. building a better case for sales BAKERY and DELI USE AND SERVICE MANUAL WARRANTY INFORMATION SPECIFICATIONS
More informationINSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250
INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250 Release Date: March 24, 2004 Publication Number: 92181INS Revision Date: April 07, 2014 Revision: G Visit the Cornelius web site at www.cornelius.com
More informationINSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY
INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY TABLE OF CONTENTS Warnings...3 Package Contents...3 General Information...3 Supply Ducting And Registers...3 Routing 115 VAC Wiring...5
More informationModel 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA
Model 20201/20201-A/20201-B Wind Sensor Heater User's Manual All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA www.allweatherinc.com 20201 Wind Sensor Heater User's Manual CONTENTS INTRODUCTION...1
More informationUse this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30
273 Branchport Avenue Long Branch, N.J. 07740 (800) 631-2148 Thank you for using our products. www.wheelockinc. com INSTALLATION INSTRUCTIONS HORN SPEAKER WITH MULTI-TAP TRANSFORMER Use this product according
More informationFrosty Factory of America, Inc.
Frosty Factory of America, Inc. 2301 S. Farmerville St., Ruston, LA 71270 frostyfactory.com (318) 255-1162 (800) 544-4071 (318) 255-1170 fax Auto Fill System & Tank Service Manual All technical data, pictures
More informationUltraviolet Monitoring System. Part Numbers UV/MS-1 V3 UV/MS-2 V3. Installation And Operations Manual
Ultraviolet Monitoring System Part Numbers UV/MS-1 V3 UV/MS-2 V3 Installation And Operations Manual 2 System Description The Wyckomar UV Monitor measures true UV intensity at 254 nm, which is the effective
More informationTC-720 RECYCLING BALER
OPERATING AND MAINTENANCE INSTRUCTIONS TC-720 RECYCLING BALER READ INSTRUCTIONS THOROUGHLY BEFORE OPERATING Sept. 06, 2013 3451 S. 40th Street Phoenix, AZ 85040 602.437.5020 800.223.4540 www.tsissg.com
More informationWILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS
INSTRUCTION MANUAL FOR WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS DE3 - DE5 OPERATIONS GENERAL This instruction manual covers the installation, operation, maintenance and troubleshooting
More informationModel Number Structure
Element Burnout Detector Accurate Detection of Element Burnout Regardless of Capacities Accurately detects a burned heater element or elements incorporated by a molding machine or packing machine and outputs
More informationSTEAMPRO. Steam Generator Troubleshooting and Service Guide
STEAMPRO Steam Generator Troubleshooting and Service Guide TABLE OF CONTENTS Page PREFACE... 1 I. STEAMPRO STEAM GENERATOR SYSTEM...2 II. PLUMBING AND ELECTRICAL...3-4 III. SYSTEM OVERVIEW... 5-10 IV.
More informationOperator s Manual for Morse Hydra-Lift Drum Karrier Model 400A
Contents Page Receiving Procedures................. 1 Warranty............................... 1 Safety Information..................... 1-2 Machine Description................... 3-4 Operating Instructions...................
More informationVENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS
VENSTAR FAN COIL THERMOSTAT FAN COIL THERMOSTAT T1070 NON- PROGRAMMABLE 2 OR 4 PIPE SYSTEMS Remote sensor ready 3 speed fan control Self-prompting adjustment Auto 2-pipe changeover when used with ACC-SENFC
More informationStatement of Responsibilities
Statement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and
More informationPLAY IT SAFE! OPERATION, MAINTENANCE AND INSTALLATION MANUAL FOR VERTICAL RECYCLER BALER INCLUDING THESE MODELS:
PLAY IT SAFE! OPERATION, MAINTENANCE AND INSTALLATION MANUAL FOR VERTICAL RECYCLER BALER INCLUDING THESE MODELS: V-4830 V-4830HD V-6030LP V-6030 V-6030HD V-6042LP V-7230HD A DOVER INDUSTRIES COMPANY VERNON,
More informationWRAS TEST & ACCEPTANCE CRITERIA Issue No: 1 Date of issue: October Sheet 1 of 7
WRc Evaluation & Testing Centre Ltd Test Code Sheet Number 1 2 1 1 17 WRAS TEST & ACCEPTANCE CRITERIA Issue No: 1 Date of issue: October 1999 Sheet 1 of 7 TEST CODE SHEET 1. TYPE OF TEST(S) Performance
More informationENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL
ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001829 OPERATIONS AND MAINTENANCE MANUAL Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1.0 SCOPE: This Operations and Maintenance
More informationOnce the sensors are mounted and connected to the EGI-RLC-MM, each sensor needs to be adjusted as follows:
Description: The Rechner KAS series sensors are ideal for use as level detection devices. The sensors work equally well for liquids, granulates, or powders. When a system is required to replenish a bin
More informationOperator s Manual for Morse Vertical-Lift Drum Pourers
Contents Page Receiving Procedures.................... 1 Warranty............................. 1 Safety Information..................... 1-2 Machine Description................... 3-4 Operating Instructions....................
More informationMANUAL BOOK Sensor faucet
MANUAL BOOK Sensor faucet Model: Mfr Code: 893604393HDF 68 SmartHome Co., Ltd. HDF68/V2.0/0613 SENSOR FAUCET AUTO FAUCET Model: The high class house! User Manual Thank you for choosing sensor faucet of
More informationINSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE
INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO--175 8 VALVE Release Date: March 24, 2004 Publication Number: 620917902INS Revision Date: April 08, 2014 Revision: E Visit the Cornelius web site
More informationFLAKER/DCM SEQUENCE OF OPERATION
FLAKER/DCM SEQUENCE OF OPERATION H O S H I Z A K I A M E R I C A The Flaker and DCM series of ice machines use a completely different ice making process than the cuber style of icemaker. The Flaker has
More informationModel Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:
Model 2102 Gas Alarm Panel APPLICABILITY & EFFECTIVITY This manual provides instructions for the following Sierra Monitor products: Model Description 2102-00 Alarm Panel 2 Channel 2102-01 Alarm Panel 2
More informationTypical Mount Height. Combustion Chamber
! WARNING: This heater must be installed and serviced by trained gas installation and service personnel only! Improper installation, adjustment, alteration, service or maintenance can cause property damage,
More informationINSTALLATION MANUAL. Double Electric Wall Oven
INSTALLATION MANUAL Double Electric Wall Oven 799258 BLUESTAR INSTALLATION INSTRUCTIONS FOR THE RESIDENTIAL ALL ELECTRIC WALL OVEN FOR THE HOME MODELS DEWO THIS APPLIANCE WAS DESIGNED FOR EASE OF INSTALLATION
More informationJ120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D
INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER J120 STEAM BOOSTER J120 Steam Booster Manual REVISION HISTORY Revision Letter Revision Date Made by Applicable ECNs Details A 10-27-04 CBW
More informationTURBO Hooded Fans. Installation & Operator s Manual (14, 18, & 24 Direct Drive)
TURBO Hooded Fans Installation & Operator s Manual (14, 18, & 24 Direct Drive) August 1996 MV1089B8 WARRANTY INFORMATION Chore-Time Equipment warrants each new product manufactured by it to be free from
More informationAR861-2II AR822-II AR861-3II. ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY 13501
ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY 13501 AR822-II AR861-2II AR861-3II (Corporate Sales) 85 Middle Road Dunkirk, NY 14048 www.argoindustries.com An ISO 9001-2000 Certified Company P/N
More informationDisposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU
BURGER KING BKSDU Burger King Shortening Disposal Unit (BKSDU) Operation, Service & Parts Manual Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified
More informationICE/BEVERAGE DISPENSER
Illustrated Parts List ICE/BEVERAGE DISPENSER Model: Enduro-2XX intellicarb Publication Number: 6209956IPL Revision Date: August 3, 200 Release Date: March 26, 204 Revision: B Visit the Cornelius web site
More informationOperator s Manual. Linear Asphalt Compactor. Jesse D. Doyle Isaac L. Howard, PhD Mississippi State University. January 2010 CMRC M 10-1 Version 1
Operator s Manual Linear Asphalt Compactor Mississippi Department of Transportation Jesse D. Doyle Isaac L. Howard, PhD Mississippi State University An Industry, Agency & University Partnership January
More information+91-8048761972 Bajaj Steel Industries Limited http://www.bajajsteelindustries.com/ We are engaged in manufacturing, supplying and exporting a wide range of Industrial Machines, Material Handling Equipment
More informationOPERATOR S MANUAL. For BURLY ATTACHMENTS
OPERATOR S MANUAL For BURLY ATTACHMENTS April 4, 2018 Clod-Buster Topsoil Screener LIMITED WARRANTY Burly Attachments, LLC warrants to the original Purchaser, all products, manufactured by it, to be free
More information7.0 Applying Basic Electricity Principles to Service Propane Appliances Skill Evaluation Packet (Updated 11/2012)
7.0 Applying Basic Electricity Principles to Service Propane Appliances Skill Evaluation Packet (Updated 11/2012) Section One Task 1 Task 2 Task 3 Section Two Task 1 Task 2 Task 3 Task 4 Identify Troubleshooting
More information92831 TEL: (714) FAX:
Document No. 1800-11 High-Performance Vacuum/Nitrogen Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton,
More informationExpanded Backup Control Installation & Operator s Instruction Manual
Installation & Operator s Instruction Manual March 2004 CTB Inc. Warranty CTB Inc. Warranty CTB Inc. warrants each new Chore-Tronics product manufactured by it to be free from defects in material or workmanship
More informationInstallation, Operation and Maintenance Manual for the Potable Water System Model: PWS-01 (380 VAC Suppy x 24 VDC Controls)
Installation, Operation and Maintenance Manual for the Potable Water System Model: PWS-01 (380 VAC Suppy x 24 VDC Controls) (Part No: KI40008AB) A part of (Intentionally Blank) Approval Sheet Divex Advitium
More informationOG5000 Ozone Generator Model OG5000B-A. User Manual
OG5000 Ozone Generator Model OG5000B-A Copyright 2017 610-0082-01H DCN7785 Teledyne API 25 September 2017 Contents CONTENTS... 1 FIGURES... 2 TABLES... 2 1. GENERAL PRECAUTIONS... 3 Safety... 5 Safety
More informationManual. Industrial Air Curtain Model IF. English. Version 1.1
Manual Industrial Air Curtain Model IF Version 1.1 Q 27-06-2007 English B Copyright All the information and draings in this manual are the property of Biddle and may not be used (other than for the actual
More informationInstallation & Maintenance Instructions. Smart Guard Ultra ZERO AIR LOSS CONDENSATE DRAIN 02/09
Installation & Maintenance Instructions Smart Guard Ultra ZERO AIR LOSS CONDENSATE DRAIN 02/09 GENERAL OPERATION The Smart Guard Ultra is a zero-air-loss, electronic level sensing condensate drain. By
More informationTHERMAL SYSTEMS, INC. Installation and Operation Manual
THERMAL SYSTEMS, INC. Installation and Operation Manual Revised September 2016 1. GENERAL SAFETY INFORMATION 1.1 Specification Never exceed the maximum allowable temperature or pressure ratings. Never
More information