1 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your uilding. 5. Leave the uilding. 6. Immediately call your local gas supplier after leaving the uilding. Follow the gas supplier s instructions. 7. If you cannot reach your gas supplier, call the Fire Department. WARNING Gas-Fired, Low Intensity Unitary Heater Installation, Operation & Service Manual Fire Hazard Do not store or use gasoline or other flammale vapors and liquids in the vicinity of this or any other appliance. Some ojects will catch fire or explode when placed close to heater. CTH3-80 CTH3-115 CTH3-150 CTH3-200 Failure to follow these instructions can result in death, injury or property damage. WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation, Operation and Service Manual thoroughly efore installing or servicing this equipment. Installation must e done y a contractor qualified in the installation and service of gas-fired heating equipment or your gas supplier. Installer Please take the time to read and understand these instructions prior to any installation. Installer must give a copy of this manual to the owner. Owner Keep this manual in a safe place in order to provide your serviceman with necessary information. Quality in Any Language Copyright 2005 Roerts-Gordon Roerts-Gordon, LLC 1250 William Street P.O. Box 44 Buffalo, New York Telephone: Fax: Toll Free: P/N NA Rev C 10/05

2

3 TABLE OF CONTENTS SECTION 1: Heater Safety Manpower Requirements... 1 SECTION 2: Installer Responsiility Wall Tag Corrosive Chemicals National Standards and Applicale Codes... 2 SECTION 3: Critical Considerations Required Clearances to Comustiles... 3 SECTION 4: National Standards and Applicale Codes Gas Codes Aircraft Hangars Pulic Garages Electrical Venting High Altitude... 7 SECTION 5: Major Components Standard Parts List... 9 SECTION 6: Heater Installation Burner Tue Installation Tue Clamp Package Installation Coupling and Tue Assemly Turulator Installation Installation Burner Installation SECTION 7: Optional Heater Accessories U-Tue Configuration Elow Package Configuration Side Extension Lower Clearance Shield Installation Two-Foot Decorative Grille Installation One-Foot Decorative Grille Installation Protective Grille Installation SECTION 8: Venting Venting Unvented Operation Horizontal Venting Vertical Venting Unvented Operation Tue Termination Length Requirements Horizontal Ventilation 4 in (10 cm) Pipe Vertical Ventilation 4 in (10 cm) Pipe Common Side Wall Venting Common Vertical Venting Outside Comustion Air Supply SECTION 9: Gas Piping SECTION 10: Wiring Standard Heater Configuration Central and Satellite Heaters (Zoning Capaility) Communication Wiring within a Zone of Heaters Communication Wiring within a Zone of Heaters (continued) Heat Demand Control Wiring Internal Wiring Ladder Diagram Line Voltage Power Wiring Electrical Connection to the Burner Low Voltage Control Wiring Installation SECTION 11: Operation and Maintenance Sequence of Operation To Shut Off Heater To Start Heater Pre-Season Maintenance and Annual Inspection Maintenance Checklist SECTION 12: Trouleshooting Control LED General LED Codes Trouleshooting Flow Chart Manifold Gas Pressure Measurement Pneumatic Connections SECTION 13: Replacement Parts SECTION 14: General Specifications Material Specification Heater Specifications Suspension Specifications Controls Specifications SECTION 15: The ROBERTS GORDON VANTAGE MODULATING Warranty All rights reserved. No part of this work covered y the copyrights herein may e reproduced or copied in any form or y any means - graphic, electronic, or mechanical, including photocopying, recording, taping or information storage and retrieval systems - without the written permission of Roerts-Gordon. Printed in U.S.A.

4

5 TABLE OF FIGURES Figure 1: Standard... 3 Figure 2: One Side... 4 Figure 3: Two Side s... 4 Figure 4: 45 Tilt... 4 Figure 5: U-Tue, Standard... 5 Figure 6: U-Tue, Figure 7: U-Tue, Opposite Figure 8: 2-Foot Deco Grille, 1-Foot Deco Grille and Protective Grille... 6 Figure 9: Lower Clearance Shield... 6 Figure 10: Venting... 6 Figure 11: Major Component Descriptions... 8 Figure 12: Critical Hanger Placement Figure 13: Linear Heater Assemly Overview Figure 14: Linear Heater Layout Overview Figure 15: U-Tue Heater Assemly Overview Figure 16: U-Tue Heater Layout Overviews Figure 17: Joint Detail Figure 18: Tue Termination Figure 19: Gas Connection with Flexile Gas Hose Figure 20: Zone Sensor Wiring Diagram Figure 21: Central Heater Jumper Settings Figure 22: Satellite Heater Jumper Setting Figure 23: Communication Wiring within a Zone of Heaters Figure 23: Communication Wiring within a Zone of Heaters (continued) Figure 24: Thermostat Control Wiring Diagram Figure 25: Analog Control Signal Wiring Diagram Figure 26: Potentiometer Control Wiring Diagram... 46

6

7 SECTION 1: HEATER SAFETY SECTION 1: HEATER SAFETY Your Safety is Important to Us! This symol is used throughout the manual to notify you of possile fire, electrical or urn hazards. Please pay special attention when reading and following the warnings in these sections. Installation, Service and Annual Inspection of heater must e done y a contractor qualified in the installation and service of gas-fired heating equipment. Read this manual carefully efore installation, operation or service of this equipment. This heater is designed for heating nonresidential indoor spaces. Do not install in residential spaces. These instructions, the layout drawing, local codes and ordinances, and applicale standards that apply to gas piping, electrical wiring, venting, etc. must e thoroughly understood efore proceeding with the installation. Thin sheet metal parts, including the aluminum reflector portion of the heater and the various venting components, have sharp edges. To prevent injury, the use of work gloves is recommended. The use of gloves will also prevent the transfer of ody oils from the hands to the surface of the reflector. Before installation, check that the local distriution conditions, nature of gas and pressure, and adjustment of the appliance are compatile. 1.1 Manpower Requirements To prevent personal injury and damage to the heater, two persons will e required for installation. 1

8 CTH3-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL SECTION 2: INSTALLER RESPONSIBILITY The installer is responsile for the following: To install the heater, as well as the gas and electrical supplies, in accordance with applicale specifications and codes. Roerts-Gordon recommends the installer contact a local uilding inspector or Fire Marshal for guidance. To use the information given in a layout drawing and in the manual together with the cited codes and regulations to perform the installation. To install the heater in accordance with the Clearances to Comustiles. To furnish all needed materials not furnished as standard equipment. To plan location of supports. To provide access to urners for servicing on all sides, for urner removal. To provide the owner with a copy of this installation, operation and service manual. To never use heater as support for a ladder or other access equipment and never hang or suspend anything from heater. To ensure there is adequate air circulation around the heater and to supply air for comustion, ventilation and distriution in accordance with local codes. To safely and adequately install heater using materials with a minimal working load of 75 ls (33 kg). 2.1 Wall Tag A laminated wall tag is availale for the heater as a permanent reminder of the safety instructions and the importance of the required clearances to comustiles. Please contact Roerts-Gordon or your ROBERTS GORDON independent distriutor to otain the wall tag. Affix the tag y peeling off the acking of the adhesive strips on the rear surface and position the tag on a wall near the heater (e.g. thermostat or ROBERTS GORDON BZC Controller). A copy of the wall tag (P/N ) is illustrated on the ack cover. For an immediate solution, you may affix this copy on the wall near the heater. Know your model numer and installed configuration. Model numer and installed configuration are found on the urner and in the Installation, Operation and Service Manual. See Page 3, Figure 1 through Page 6, Figure 10. Write the proper clearance dimensions in permanent ink according to your model numer and configuration in the open spaces on the tag. 2.2 Corrosive Chemicals CAUTION Do not use heater in an area containing corrosive chemicals. Avoid the use of corrosive chemicals to ensure a longer life of the urner, tuing and other parts. Failure to follow these instructions can result in property damage. Roerts-Gordon cannot e responsile for ensuring that all appropriate safety measures are undertaken prior to installation; this is entirely the responsiility of the installer. It is essential that the contractor, the su-contractor, or the owner identifies the presence of comustile materials, corrosive chemicals or halogenated hydrocarons* anywhere in the premises. * Halogenated Hydrocarons are a family of chemical compounds characterized y the presence of halogen elements (fluorine, chlorine, romine, etc.). These compounds are frequently used in refrigerants, cleaning agents, solvents, etc. If these compounds enter the air supply of the urner, the life span of the heater components will e greatly reduced. An outside air supply must e provided to the urners whenever the presence of these compounds is suspected. Warranty will e invalid if the heater is exposed to halogenated hydrocarons. 2.3 National Standards and Applicale Codes All appliances must e installed in accordance with the latest revision of the applicale standards and national codes. This refers also to the electric, gas and venting installation. Note: Additional standards for installations in Pulic Garages, Aircraft Hangars, etc. may e applicale. 2

9 SECTION 3: CRITICAL CONSIDERATIONS SECTION 3: CRITICAL CONSIDERATIONS 3.1 Required Clearances to Comustiles Clearances are the required distances that comustile ojects must e away from the heater to prevent serious fire hazards. Comustiles are materials, that may catch on fire and include common items such as wood, paper, ruer, faric, etc. Maintain clearances to comustiles at all times for safety. Clearances for all heater models are located on the urner of the heater and on Page 3, Figure 1 through Page 6, Figure 10 in this manual. Check the clearances on each urner for the model heater eing installed to make sure the product is suitale for your application and the clearances are maintained. Read and follow the safety guidelines elow: Keep gasoline or other comustile materials including flammale ojects, liquids, dust or vapors away from this heater or any other appliance. Maintain clearances from heat sensitive material, equipment and workstations. Maintain clearances from vehicles parked elow the heater. Maintain clearances from swinging and overhead doors, overhead cranes, vehicle lifts, partitions, storage racks, hoists, uilding construction, etc. In locations used for the storage of comustile materials, signs must e posted to specify the WARNING Fire Hazard Some ojects will catch fire or explode when placed close to heater. Keep all flammale ojects, liquids and vapors the required clearances to comustiles away from heater. Failure to follow these instructions can result in death, injury or property damage. maximum permissile stacking height to maintain required clearances from the heater to the comustiles. Signs must e posted adjacent to the heater thermostat. In the asence of a thermostat, signs must e posted in a conspicuous location. Consult local Fire Marshal, Fire Insurance Carrier or other authorities for approval of proposed installation when there is a possiility of exposure to comustile airorne materials or vapors. Hang heater in accordance to the minimum suspension requirements on Page 10, Figure 12. If the radiant tues must pass through the uilding structure, e sure that adequate sleeving and fire stop is installed to prevent scorching and/or fire hazard. NOTE: 1. All dimensions are from the surfaces of all tues, couplings and elows. 2. Clearances B, C and D can e reduced y 50% after 25' (7.5 m) of tuing downstream from where the urner and urner tue connect. FIGURE 1: STANDARD REFLECTOR (inches) (centimeters) A Model A B C D A B C D CTH C B D CTH CTH CTH

10 CTH3-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL NOTE: 1. All dimensions are from the surfaces of all tues, couplings and elows. 2. Clearances B, C and D can e reduced y 50% after 25' (7.5 m) of tuing downstream from where the urner and urner tue connect. FIGURE 2: ONE SIDE REFLECTOR (inches) (centimeters) A C B D Model A B C D A B C D CTH CTH CTH CTH FIGURE 3: TWO SIDE REFLECTORS (inches) (centimeters) A C B D Model A B C D A B C D CTH CTH CTH CTH FIGURE 4: 45 TILT REFLECTOR (inches) (centimeters) A C B D Model A B C D A B C D CTH CTH CTH CTH

11 SECTION 3: CRITICAL CONSIDERATIONS NOTE: 1. All dimensions are from the surfaces of all tues, couplings and elows. 2. Clearances B, C and D can e reduced y 50% after 25' (7.5 m) of tuing downstream from where the urner and urner tue connect. FIGURE 5: U-TUBE, STANDARD REFLECTOR (inches) (centimeters) A B D C Model A B C D A B C D CTH CTH CTH CTH FIGURE 6: U-TUBE, 45 A B D C (inches) (centimeters) Model A B C D A B C D CTH CTH CTH CTH FIGURE 7: U-TUBE, OPPOSITE 45 REFLECTOR (inches) (centimeters) A B D C Model A B C D A B C D CTH CTH CTH CTH

12 CTH3-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL NOTE: 1. All dimensions are from the surfaces of all tues, couplings and elows. 2. Clearances B, C and D can e reduced y 50% after 25' (7.5 m) of tuing downstream from where the urner and urner tue connect. FIGURE 8: 2-FOOT DECO GRILLE, 1-FOOT DECO GRILLE AND PROTECTIVE GRILLE (inches) (centimeters) A C B D Model A B C D A B C D CTH CTH CTH CTH FIGURE 9: LOWER CLEARANCE SHIELD* (inches) (centimeters) A C B D Model A B C D A B C D CTH CTH CTH CTH UNAPPROVED - - UNAPPROVED - *When installed in the first 10 (3 m). FIGURE 10: VENTING Unvented Radiant Tues Vented A E Vent Pipes F (inches) (centimeters) Model A E F A E F CTH CTH CTH CTH

13 SECTION 4: NATIONAL STANDARDS AND APPLICABLE CODES SECTION 4: NATIONAL STANDARDS AND APPLICABLE CODES 4.1 Gas Codes The type of gas appearing on the nameplate must e the type of gas used. Installation must comply with national and local codes and requirements of the local gas company. United States: Refer to National Fuel Gas Code, ANSI Z latest revision (same as NFPA 54). Canada: Refer to CAN/CGA B149.1 and B149.2: Installation Codes for Gas Burning Appliances. 4.2 Aircraft Hangars Installation in aircraft hangars must e in accordance with the following codes: United States: Refer to Standard for Aircraft Hangars, ANSI/NFPA latest revision. Canada: Refer to Standard CAN/CGA B149.1 and B In aircraft storage and servicing areas, heaters shall e installed at least 10' (3 m) aove the upper surface of wings or of engine enclosures of the highest aircraft which may e housed in the hangar. The measurement shall e made from the wing or engine enclosure (whichever is higher from the floor) to the ottom of the heater. In shops, offices and other sections of aircraft hangars communicating with aircraft storage or servicing areas, heaters shall e installed not less than 8' (2.4 m) aove the floor. Suspended or elevated heaters shall e so located in all spaces of aircraft hangars that they shall not e suject to injury y aircraft, cranes, movale scaffolding or other ojects. Provisions shall e made to assure accessiility to suspended heaters for recurrent maintenance purposes. 4.3 Pulic Garages Installation in garages must e in accordance with the following codes: United States: Standard for Parking Structures NFPA 88A - latest revision or the Code for Motor Fuel Dispensing Facilities and Repair Garages, NFPA 30A - latest revision. Canada: Refer to CAN/CGA B149.1 and B149.2: Installation Codes for Gas Burning Appliances. Heaters must not e installed less than 8' (2.4 m) aove the floor. Minimum clearances to comustiles must e maintained from vehicles parked elow the heater. When installed over hoists, minimum clearances to comustiles must e maintained from the upper most point of ojects on the hoist. 4.4 Electrical The heater must e electrically grounded in accordance with the following codes: United States: Refer to National Electrical Code, ANSI/NFPA 70 - latest revision. Wiring must conform to the most current National Electrical Code, local ordinances and any special diagrams furnished. Canada: Refer to Canadian Electrical Code, CSA C22.1 Part 1 - latest revision. 4.5 Venting The venting must e installed in accordance with the requirements within this manual and the following codes: United States: Refer to NFPA 54/ANSI Z latest revision, National Fuel Gas Code. Canada: Refer to CAN/CGA B149.1 and B149.2: Installation Codes for Gas Burning Appliances 4.6 High Altitude These heaters are approved for installations up to 2000' (US), 4500' (Canada) without modification. Consult factory if US installation is aove 2000' (610 m) or Canadian installation is aove 4500' (1370 m). 7

14 CTH3-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL SECTION 5: MAJOR COMPONENTS FIGURE 11: Major Component Descriptions Burner with Tue Gasket Must e installed with the flame oservation window facing down. (Aluminum or Stainless Steel) Alternate overlap as shown on overview and on Page 12, Figure 14. Minimum overlap is 6 (16 cm). Burner Tue Supplied in 10' (3 m) lengths. Burner tue is always the first tue after the urner. Tue Heat Treated Aluminized Tue supplied in 10 (3 m) lengths. Tue and Hanger with Clamp Package Position this hanger no more than 4 (10 cm) away from the urner. Tue and Hanger Suspend system from these hangers. Coupling Assemly with Lock End Cap Punch out center section to accommodate tue. Vent Adapter Support Strap & Wire Form Flex Gas Line with Shut Off Cock Turulator Turulator must e installed in the last standard section of tue. Turulator is not required on the CTH For installation see Page 15, Section

15 SECTION 5: MAJOR COMPONENTS 5.1 Standard Parts List Tale 1: Contents of Burner Carton Part No. Description CTH3-80 CTH3-115 CTH3-150 CTH XXXXX Burner Assemly (Rate and Fuel Varies) Gasket (Burner to Burner Tue) NA Installation, Operation and Service Manual Hex Head Bolts 5/16-18 Rolok Split Lock Washer Pipe Nipple (Black) 1/2 NPT x * Flexile Stainless Steel Gas Hose - 1/2" NPT (US Models Only) * Flexile Stainless Steel Gas Hose - 3/4" NPT (US Models Only) Turulator Adapter Turulator 2.5' (76 cm), Aluminized Steel Wire Terminal Receptacle.187 x Cale Grommet with Tie *Canadian Models: Ruer (Type 1) Gas Hoses availale as an accessory. See Page 36, Section 9. Tale 2: Contents of Core and Extension Packages Core Packages (Aluminized) Extension Packages (Aluminized) Part No. Description 10' (3m) 20' (6m) 30' (9m) 40' (12m) 10' (3m) 20' (6m) 30' (9m) 40' (12m) Tue, HT Aluminized, 10' (3m) Burner Tue, ALUMI-THERM Steel, 10' (3m) Burner Tue, HT ALUMI-THERM Steel, 10' (3m) Coupling Assemly Standard, 8' (3.5m) End Cap Tue and Hanger S-Hook Support Package (Strap, Wire Form, Screws) U-Clip Package Vent Adapter Tue Clamp Package Part Numer CP10ALUM CP20ALUM CP30ALUM CP40ALUM EXP10ALUM EXP20ALUM EXP30ALUM EXP40ALUM Tale 3: CTH3-Series Component Package Guide Model Tuing Length Core Packages Minimum Aluminized CTH ' (6m) CP20ALUM CTH ' (9m) CP30ALUM CTH ' (12m) CP40ALUM CTH ' (15m) CP30ALUM + EXP20ALUM Additional tuing length may e added to heater. Tuing must e heat-treated, aluminized or porcelain coated. Any additional tuing lengths are considered as vent length for length determination. Maximum venting length for minimum heater length is 45' (13.7 m). 9

16 CTH3-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL SECTION 6: HEATER INSTALLATION WARNING Suspension Hazard Burner is secured to urner tue y olts and lockwashers. Hang heater with materials with a minimum working load of 75 ls (33 kg). Failure of the supports can result in death, injury or property damage. To ensure your safety, and comply with the terms of the warranty, all units must e installed in accordance with these instructions. The gas or the electrical supply lines must not e used to support the heater. FIGURE 12: Critical Hanger Placement Do not locate the gas or electric supply lines directly over the path of the flue products from the heater. The heater must e installed in a location that it is readily accessile for servicing. The heater must e installed in accordance with clearances to comustiles as indicated on the heater and in this instruction manual. The gas inlet pressure must e maintained as indicated on the rating plate. Typical installation configurations are shown in Figure 12. Expansion and contraction of the tue dictates that the minimum suspension lengths in the tale on Page 10, Figure 12 e maintained. Description Part Numer S-Hook Tue/ Hanger Run Length Typical Expansion Minimum X Length ±1 (3 cm) ±2 (5 cm) ±3 (8 cm) 24 10

17 SECTION 6: HEATER INSTALLATION FIGURE 13: Linear Heater Assemly Overview End Cap Burner Tue Clamp Package Burner Tue Tue and Hanger Coupling Support Tue Turulator (With Select Models) Vent Adapter U-Clips 11

18 CTH3-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL FIGURE 14: Linear Heater Layout Overview LEGEND Burner g c d e f Tue 20' Tue Length Tue/ Hanger Coupling Assemly g c d e e Vent Adapter f a = 14" (36 cm) reflector width (not shown) = 2" (5 cm) end cap to urner g c 30' Tue Length d e e e c = 2" (5 cm) end cap to hanger f d = 7'6" (229 cm) distance first hanger e = 10' (305 cm) distance etween hangers g c 40' Tue Length d e e e e f = 9.5" (24 cm) urner height g = 17.5" (44 cm) urner length f 50' Tue Length g c d e e e e e g f c 60' Tue Length d e e e e e e f 70' Tue Length g c d e e e e e e e f 80' Tue Length 12

19 SECTION 6: HEATER INSTALLATION Step 6.1 Burner Tue Installation NOTE: Tuing requires a downward slope of 1/2" (13 mm) per 20' (6 m) away from urner. 7' 6" ± 1' (229 cm ± 25 cm) Description Part Numer Burner Tue 03051XXX S-Hook Tue/ Hanger Step 6.2 Tue Clamp Package Installation Description Part Numer Tue Clamp Package Tue Clamp Bolt Flat Washer Nut Tue Clamp Flat Washer Bolt Nut (torque 120 in/l Nm) 13

20 CTH3-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL Step 6.3 Coupling and Tue Assemly A Close coupling with ta. Ta B Start Slide ar/coupling Lock. Slide Bar/Coupling Lock Open 3" (8 cm) to 4" (10 cm) Wide end Coupling C Closed Insert tues into coupling. D Tighten coupling to join tues. Tue Orient coupling so that the impact lock is in the 2:00 or 10:00 o clock positions Tue Tue Description Part Numer Coupling Slide ar/coupling Lock Tue 91409XXX Slide Bar/Coupling Lock Coupling Step Coupling and Tue Assemly (Continued) Tighten slide ar as shown elow. Drive Slide Bar until tight. End of Slide Bar should e within tolerance listed elow. Correct Slide Bar dimensions ± 2" (5 cm) Incorrect Slide Bar position Repeat Step 6.3 A - D until all tues are assemled. See Page 15, Section

21 SECTION 6: HEATER INSTALLATION Step Coupling and Tue Assemly (Continued) Tue Length Model Minimum CTH (6 m) CTH (9 m) CTH (12 m) CTH (15 m) 7' 6" ± 1' (229 cm ± 25 cm) 10' ± 1' (305 cm ± 25 cm) Total Overall Tue Length Step 6.4 Turulator Installation Turulator must e installed in the last standard section of tue. Turulator is not required on the CTH Turulator 2.5' Section Turulator Adapter Ta Twist Turulator Installation CTH3-80 2nd 10' Section CTH rd 10' Section CTH th 10' Section CTH3-200 N/A Description Part Numer Turulator Adapter Turulator Section 2.5' Tue 91409XXX Pull String Fold ta around outside of tue nearest to the vent to hold turulator in place. Where a vent sleeve is used, do not fold ta. 15

22 CTH3-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL Step 6.5 Installation NOTE: All tue surfaces must e covered y a reflector, except for a U-Tue. Hanger Burner Tue Description Part Numer Tue/ Hanger Burner Tue 03051XXX

23 SECTION 6: HEATER INSTALLATION Step 6.5.1, U-Clip and Support Installation The pictorial drawings of the heater construction in reflector supports and U-clips depends on the Section 6 are schematic only and provide a general individual installation. Use either pop rivets or sheet guideline of where hangers, reflector supports and metal screws instead of u-clips when installing end U-clips are to e installed. caps and joint pieces in areas where impact and high wind may e a factor. The following rules must e To ensure proper expansion and contraction movement of the reflectors, a comination of U-clips oserved. and reflector supports are used. The positioning of Step The first reflector after the urner must e affixed in the middle of the reflector with a reflector support and tight screws. Tight Sheet Metal Screw Wire Form End Cap First Support Strap U-Clips Overlap must e a minimum of 6" (16 cm). 2B Slip Overlap 6" (16 cm) 2. The overlap at the first and second reflector is a slip overlap. Thereafter, every third reflector joint is a slip overlap. A slip overlap is achieved y either: a.) oth reflectors lay inside a hanger. (No reflector support needed)..) using a reflector support with loose screws at the reflector overlap. Loose screws loosened 1/16" (2 mm) to allow slippage. 2A Slip Overlap 3A Non-Slip Overlap 3. The remaining reflector overlaps require a non-slip overlap connection. To affix the reflectors together in a non-slip overlap either: a.) use reflector support and tight screws..) if oth reflectors lay inside a hanger, u-clips or sheet metal screws may e used. This section of three reflectors joined together must e affixed to the tue with at least one reflector support with tight screws. Description Support Package Wire Form Support Strap Screw #8 x 3/4 U-Clip Package End Cap Part Numer XX Support Tight screws 3B Non-Slip Overlap U-Clip (2 clips per non-slip overlap inside a hanger) 17

24 CTH3-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL Step 6.6 Burner Installation Burner Gasket S-Hook Burner Tue Burner must e installed with the flame oservation window facing down. Description Part Numer Bolt Burner 034XXXXX Lock Washer Gasket Lock Washer Bolt (Torque 120 in/l Nm) 18

25 SECTION 7: OPTIONAL HEATER ACCESSORIES SECTION 7: OPTIONAL HEATER ACCESSORIES 7.1 U-Tue Configuration Heaters are approved for optional U-Tue configurations. The U-Tue may e installed in either a standard horizontal position, a 45 position or in an opposite 45 position as shown on Page 5, Figure 5 through Figure 7. When using a U-Tue configuration, the following additional rules must e adhered to: FIGURE 15: U-Tue Heater Assemly Overview A minimum of 10' (3 m) on CTH3-80 and a minimum of 15' (4.5 m) on CTH3-115/150/200 is required etween the urner and the U-Tue. The correct turulator (See Page 15, Figure 6.4) must e installed in the last standard section of tue. The urner must never e operated in a tilted position. The heater must e properly supported at all locations. See Page 20, Figure 16. U-Tue Support Bracket Support Burner Tue Clamp Package Burner Tue (Turulator With Select Models) Tue U-Tue, Standard 1 2 U-Tue, U-Tue, Opposite Tight U-Bolt 4" (10 cm) U-Bolt, secured to Burner Tue with 1/4" (6 mm) Lockwashers and 1/4-20 Hex Nuts Couplings Loose U-Bolt 4" (10 cm) U-Bolt, secured to Bracket with 1/4" (6 mm) Lockwashers and 1/4-20 Hex Nuts on top and ottom to allow for tue expansion and contraction U-Bolt Nut Lock Washer Lock Washer Nut U-Clips End Caps U-Tue 18" (457 mm) Center to Center 19

26 CTH3-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL FIGURE 16: U-Tue Heater Layout Overviews LEGEND g c e Burner Tue 10' Tue 5' ** h g c 20' Tue Length* d f Tue/ Hanger Coupling Assemly U-Tue a = 14" (36 cm) reflector width (not shown) h g 30' Tue Length ** c d e = 2" (5 cm) end cap to urner c = 2" (5 cm) end cap to hanger d = 7'6" (229 cm) distance first hanger h g 40' Tue Length c d e f e = 10' (305 cm) distance etween hangers f = 5' (153 cm) distance etween last full tue hanger and half tue hanger h g c 50' Tue Length* ** d e e g = 17.5" (44 cm) urner length h = 9.5" (24 cm) urner height *Requires the last reflector efore the U-Tue to e cut in half for use on oth sides. h g c 60' Tue Length d e e f **Requires the last tue efore the U-Tue to e cut in half for use on oth sides. h 70' Tue Length** g c d e e e h 80' Tue Length 20

27 SECTION 7: OPTIONAL HEATER ACCESSORIES 7.2 Elow Package Configuration Step Elow Installation Tue Coupling Description Part Numer Elow Package Elow Coupling End Cap Joint Piece U-Clip Package Step Elow Installation 90 Elow Minimum Distance Required Between Burner and Elow Minimum Model Distance CTH ' (3m) CTH3-115 CTH ' (4.5m) CTH3-200 Tue Coupling Step Joint Installation Joint Scrie Contour Flatten Edge 1" (2.5 cm) Maximum 21

28 CTH3-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL Step Joint Installation Cut away contour with tin snips. Punch/drill six 3/32" (2 mm) holes. Step Joint Detail Install reflector end cap. Attach reflector joint with six #8 sheet metal screws. FIGURE 17: Joint Detail Joint 22

GordonRay NP. Negative Pressure Unitary Infrared Heater. Installation, Operation & Service Manual NP-40 NP-60 NP-90 NP-125 NP-150 NP-175 NP-200

GordonRay NP. Negative Pressure Unitary Infrared Heater. Installation, Operation & Service Manual NP-40 NP-60 NP-90 NP-125 NP-150 NP-175 NP-200 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Leave the building. 6. Immediately

More information

Blackheat BH. The Economical Unitary Infrared Heater. Installation, Operation & Service Manual BH-40 BH-60 BH-80 BH-100 BH-115

Blackheat BH. The Economical Unitary Infrared Heater. Installation, Operation & Service Manual BH-40 BH-60 BH-80 BH-100 BH-115 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Leave the building. 6. Immediately

More information

Rapid NP. Negative Pressure Unitary or Multiburner Infrared Heater. Installation, Operation & Service Manual WARNING

Rapid NP. Negative Pressure Unitary or Multiburner Infrared Heater. Installation, Operation & Service Manual WARNING FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

GordonRay BH. The Economical Unitary Infrared Heater. Installation, Operation & Service Manual WARNING BH-40 BH-60 BH-80 BH-100 BH-115

GordonRay BH. The Economical Unitary Infrared Heater. Installation, Operation & Service Manual WARNING BH-40 BH-60 BH-80 BH-100 BH-115 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

The Economical, Unitary Infrared Heater Submittal: BH Series

The Economical, Unitary Infrared Heater Submittal: BH Series Blackheat BH The Economical, Unitary Infrared Heater Submittal: BH Series Job: Location: Engineer: Gas Specs: Date: QTY. MODEL NO. BH UNIT INPUT BTU/HR QTY. MODEL NO. BH UNIT INPUT BTU/HR QTY. MODEL NO.

More information

Low-Intensity, Infrared Heating Systems Submittal: HE Series

Low-Intensity, Infrared Heating Systems Submittal: HE Series Low-Intensity, Infrared Heating Systems Submittal: HE Series Job: Location: Engineer: Gas Specs: Date: QTY. MODEL NO. HE UNIT INPUT BTU/HR QTY. MODEL NO. HE UNIT INPUT BTU/HR QTY. MODEL NO. HE UNIT INPUT

More information

Blackheat HE. Vacuum Assisted Linear, Double Linear, U-Tube, and Multi-Burner Gas Fired Heating Systems. IP55 Protected Burner Box

Blackheat HE. Vacuum Assisted Linear, Double Linear, U-Tube, and Multi-Burner Gas Fired Heating Systems. IP55 Protected Burner Box FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

Blackheat. Vacuum Assisted Linear, Double Linear, U-Tube, and Multi-Burner Gas Fired Heating Systems. Installation, Operation & Service Manual WARNING

Blackheat. Vacuum Assisted Linear, Double Linear, U-Tube, and Multi-Burner Gas Fired Heating Systems. Installation, Operation & Service Manual WARNING FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

Fuel Conversion Kit Instructions

Fuel Conversion Kit Instructions FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

GordonRay DF. Installation, Operation & Service Manual DF-80 DF-100 DF-125 DF-150 DF-175 DF-200 FOR YOUR SAFETY

GordonRay DF. Installation, Operation & Service Manual DF-80 DF-100 DF-125 DF-150 DF-175 DF-200 FOR YOUR SAFETY GordonRay DF Installation, Operation & Service Manual DF-80 DF-100 DF-125 DF-150 DF-175 DF-200 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO T try to light any appliance. 3. DO T use electrical

More information

Vantage EV. Installation, Operation & Service Manual EV-80 EV-110 EV-140 EV-170 EV-200

Vantage EV. Installation, Operation & Service Manual EV-80 EV-110 EV-140 EV-170 EV-200 Vantage EV Installation, Operation & Service Manual EV-80 EV-110 EV-140 EV-170 EV-200 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches.

More information

Vantage TF. The Twin Fire Unitary Infrared Heater. Installation, Operation & Service Manual TF-160. Quality in Any Language

Vantage TF. The Twin Fire Unitary Infrared Heater. Installation, Operation & Service Manual TF-160. Quality in Any Language FOR YOUR SAFETY If you smell gas: 1.Open windows. 2.DO NOT try to light any appliance. 3.DO NOT use electrical switches. 4.DO NOT use any telephone in your building. 5.Leave the building. 6.Immediately

More information

EP-200 Series Pump. Installation, Operation & Service Manual. Quality in Any Language

EP-200 Series Pump. Installation, Operation & Service Manual. Quality in Any Language EP-200 Series Pump Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the installation,

More information

Model VSUS & VSLUS 120V 60Hz Gas-Fired, Tubular, Radiant, Low-Intensity Infrared Heater

Model VSUS & VSLUS 120V 60Hz Gas-Fired, Tubular, Radiant, Low-Intensity Infrared Heater INSTALLATION / OPERATION / MAINTENANCE Applies to: Model VSUS & VSLUS 120V 60Hz Gas-Fired, Tubular, Radiant, Low-Intensity Infrared Heater OWNERS MANUAL WARNING: Improper installation, adjustment, alteration,

More information

SECTION 7: OPTIONAL HEATER ACCESSORIES. Step Reflector Joint Installation. Step Reflector Joint Detail. FIGURE 19: Reflector Joint Detail

SECTION 7: OPTIONAL HEATER ACCESSORIES. Step Reflector Joint Installation. Step Reflector Joint Detail. FIGURE 19: Reflector Joint Detail SECTION 7: OPTIONAL HEATER ACCESSORIES Step 7.2.4 Reflector Joint Installation Cut away contour with tin snips. Punch/drill six 3/32" (2 mm) holes. Step 7.2.5 Reflector Joint Detail Install reflector end

More information

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS Models: ADU5, ADU30, ADU35, ADU40, ADU45, ADL5, ADL30, ADL35, ADL40, ADL45 Single Stage Pull Through System (Negative Pressure) 0086

More information

Installation, Operation & Service Manual

Installation, Operation & Service Manual Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation, Operation and

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Push Through System (Positive Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Push Through System (Positive Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

CRV 4-40 Replacement Burner

CRV 4-40 Replacement Burner FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

COMBUSTION RESEARCH CORPORATION

COMBUSTION RESEARCH CORPORATION COMBUSTION RESEARCH CORPORATION FOR YOU SAFTEY If you smell gas: 1. Open windows 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5.

More information

CRV 4-40 Replacement Burner

CRV 4-40 Replacement Burner FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

EP-100 Pump. Installation, Operation & Service Manual

EP-100 Pump. Installation, Operation & Service Manual EP-100 Pump Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation,

More information

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure) ASSEMBLY INSTRUCTIONS - NXS SERIES OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED RADIANT

More information

Reflect-O-Ray Oil Fired EDS 3.5

Reflect-O-Ray Oil Fired EDS 3.5 COMBUSTION RESEARCH CORPORATION FOR YOU SAFTEY If you have a Fuel Oil leak: 1. Open windows 2. DO NOT try to light any appliance. 3. DO NOT use electrical equipment. 4. Shut off Fuel Oil supply. 5. Leave

More information

COMBUSTION RESEARCH CORPORATION

COMBUSTION RESEARCH CORPORATION COMBUSTION RESEARCH CORPORATION FOR YOU SAFTEY If you smell gas: 1. Open windows 2. DO T try to light any appliance. 3. DO T use electrical switches. 4. DO T use any telephone in your building. 5. Leave

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Push Through System (Positive Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Push Through System (Positive Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

EP-300 Series. Installation, Operation & Service Manual

EP-300 Series. Installation, Operation & Service Manual EP-300 Series Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation,

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Push Through System (Positive Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Push Through System (Positive Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

Installation, Operation and Service Instructions DU/DUH RANGE DUAL OUTPUT INFRARED HEATERS

Installation, Operation and Service Instructions DU/DUH RANGE DUAL OUTPUT INFRARED HEATERS Installation, Operation and Service Instructions DU/DUH RANGE DUAL OUTPUT INFRARED HEATERS WARNINGS WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

Tube Heater General Manual

Tube Heater General Manual Detroit Radiant Products Co. Tube Heater General Manual To be used in conjunction with Series 2 insert manuals. WARNING Improper installation, adjustment, alteration, service, or maintenance can cause

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY: INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS (CHECK ONE) PROPANE GAS PROJECT: ARCHITECT/ENGINEER: NAME: ADDRESS: NAME: ADDRESS: DATE: CONTRACTOR: SUBMITTED BY: NAME: ADDRESS: EQUIPMENT

More information

A. Product Data: Include rated capacities, furnished specialties and accessories.

A. Product Data: Include rated capacities, furnished specialties and accessories. BASE BID: SECTION 15542 FUEL-FIRED RADIANT HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Furnish and install a Co-Ray-Vac Low Intensity Vented Infrared Radiant Vacuum Gas Heating System. System must be certified

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS) This section is based

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Push Through System (Positive Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Push Through System (Positive Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

EP-300 Series. Installation, Operation & Service Manual

EP-300 Series. Installation, Operation & Service Manual EP-300 Series Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation,

More information

Installation, Operation, Maintenance and Parts Manual

Installation, Operation, Maintenance and Parts Manual Installation, Operation, Maintenance and Parts Manual 7DC27 thru 7DC32 Please read and save these instructions. This heater must be installed and serviced by trained gas installation and service personnel

More information

Combat. Compact Tubular Unit Heaters Installation, Commissioning, Operation & Service Manual Models CTCU 7 CTCU 11 CTCU 15 CTCU 22 CTCU 27 CTCU 32

Combat. Compact Tubular Unit Heaters Installation, Commissioning, Operation & Service Manual Models CTCU 7 CTCU 11 CTCU 15 CTCU 22 CTCU 27 CTCU 32 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

Heating safely with gas-fired infrared heaters

Heating safely with gas-fired infrared heaters Heating safely with gas-fired infrared heaters Patio Heaters F RO M TH E High Intensity Ceramic Heaters I N F R AR E D H EATE R SAF ET Y CO U N C I L Low Intensity Tube Heaters An AHRI Initiative Construction

More information

Multi-Function Cooktop

Multi-Function Cooktop INSTALLATION GUIDE Multi-Function Cooktop Contents Wolf Multi-Function Cooktop.................... 3 Multi-Function Cooktop Specifications............ 4 Multi-Function Cooktop Installation...............

More information

ELECTRIC UNIT HEATER REGULAR DUTY

ELECTRIC UNIT HEATER REGULAR DUTY ELECTRIC UNIT HEATER REGULAR DUTY Installation Form RGM 428 (MI500 Revision 0) APPLIES TO: Model EGE INDEX (by page number) Clearance to Combustibles... 3 Dimensions... 4 Electrical... 4 Fan Motor... 4

More information

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas glor sun The Original Outdoor Patio Heater Manufactured by INFRARED DYNAMICS, INC. Yorba Linda, CA 92886 U.S.A. Tel: (714) 572-4050 Fax: (714) 572-6093 Toll-Free: (888) 317-5255 www.infradyne.com SPECIFICATIONS:

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS SECTION 15540 - FUEL - FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS)

More information

Series RE Infrared Heater

Series RE Infrared Heater Series RE Infrared Heater Installation, Operation and Service Instructions WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage,

More information

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. MILLIVOLT

More information

EP-200 Series Pump. Installation, Operation & Service Manual

EP-200 Series Pump. Installation, Operation & Service Manual EP-200 Series Pump Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation,

More information

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER RBDS-1 RBD SERIES CERAMIC HEATERS NATURAL GAS (Check One) PROPANE GAS EQUIPMENT USED: ACCESSORIES: Chain Mounting Kit: Thermostat: Gas Pressure Regulator: Parabolic Extension: Gas Shut-Off Valve: Reverb

More information

INSTALLATION GUIDE. Isis. For help, call BIG-FANS or visit

INSTALLATION GUIDE. Isis. For help, call BIG-FANS or visit INSTALLATION GUIDE For help, call 1-877-BIG-FANS or visit www.igassfans.com Installation Checklist Did a structural engineer approve the mounting structure? See page 7 for Big Ass Fans-approved mounting

More information

Mighty Venter Power Vent System

Mighty Venter Power Vent System Installation and Operation Instructions Document 7008B Installation and Operation Instructions for Mighty Venter Power Vent System Models MV2, MV3, MV4, and MV5 for Mighty Therm Sizes 500-1825 FOR YOUR

More information

Installation, Operation and Service Instructions RS RANGE RESIDENTIAL INFRARED HEATERS

Installation, Operation and Service Instructions RS RANGE RESIDENTIAL INFRARED HEATERS Installation, Operation and Service Instructions RS RANGE RESIDENTIAL INFRARED HEATERS WARNINGS WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

INSTALLATION / OWNER S MANUAL

INSTALLATION / OWNER S MANUAL ultraschwank Models: UHE & InfraSave Ultimate Models: EIH HIGH RADIANT OUTPUT LOW INTENSITY TUBE TYPE INFRA RED HEATER INSTALLATION / OWNER S MANUAL WARNING Improper installation, adjustment, alteration,

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS)

More information

NOTICE: The information contained on the following page(s) was produced prior to May 1, On that date Reznor became part of Nortek, Inc.

NOTICE: The information contained on the following page(s) was produced prior to May 1, On that date Reznor became part of Nortek, Inc. NOTICE: The information contained on the following page(s) was produced prior to May 1, 2014. On that date Reznor became part of Nortek, Inc. References to any other company affiliations are no longer

More information

User s Information Manual Models: 45, ,000 Btu/hr

User s Information Manual Models: 45, ,000 Btu/hr SBR-USER_100161678_2000017137_Rev C User s Information Manual Models: 45,000-260,000 Btu/hr If the information in this manual is not followed exactly, a fire or explosion may result causing property damage,

More information

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

Caribe. Gas-Fired, Low-Intensity Infrared Heaters for Residential Garages and Light Industrial/Commercial Applications

Caribe. Gas-Fired, Low-Intensity Infrared Heaters for Residential Garages and Light Industrial/Commercial Applications FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Leave the building. 6. Immediately

More information

INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single and Two Stage Push Through System (Positive Pressure) Models:

INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single and Two Stage Push Through System (Positive Pressure) Models: INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single and Two Stage Push Through System (Positive Pressure) Models: (Hot Rolled Steel) (Aluminized Steel) PCS75 (N5,L5,N7,L7)

More information

Series TA/TX/TXR Infrared Heater Installation, Operation and Service Instructions

Series TA/TX/TXR Infrared Heater Installation, Operation and Service Instructions Series TA/TX/TXR Infrared Heater Installation, Operation and Service Instructions FOR YOUR SAFETY If you smell gas: 1. Open windows 2. Don t touch electrical switches 3. Extinguish any open flame 4. Immediately

More information

Blackheat. Vacuum Assisted Linear & U-Tube Gas Fired Radiant Heating Systems. Installation, Operation & Service Manual

Blackheat. Vacuum Assisted Linear & U-Tube Gas Fired Radiant Heating Systems. Installation, Operation & Service Manual FOR YOUR SFETY If you smell gas: 1. Open windows. 2. O NOT try to light any appliance. 3. O NOT use electrical switches. 4. O NOT use any telephone in your building. 5. Leave the building. 6. Immediately

More information

ITH-SERIES GAS-FIRED INFRARED TUBE HEATERS TECHNICAL MANUAL

ITH-SERIES GAS-FIRED INFRARED TUBE HEATERS TECHNICAL MANUAL ITH-SERIES GAS-FIRED INFRARED TUBE HEATERS TECHNICAL MANUAL mwarning: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation,

More information

Elite. Unit Heaters. Installation and Commissioning Manual. Tubular Unit Heaters Elite Range

Elite. Unit Heaters. Installation and Commissioning Manual. Tubular Unit Heaters Elite Range Elite Unit Heaters Installation and Commissioning Manual Tubular Unit Heaters Elite Range 40-115 Unit 20 Red Mill Trading Estate, Rigby Street Wednesbury, West Midlands, WS10 0NP Tel: +44(0)121 5067700

More information

! WARNING: FIRE OR EXPLOSION HAZARD. Applies to: Model SC, Separated-Combustion Duct Furnace. Model SC INSTALLATION / OPERATION / MAINTENANCE

! WARNING: FIRE OR EXPLOSION HAZARD. Applies to: Model SC, Separated-Combustion Duct Furnace. Model SC INSTALLATION / OPERATION / MAINTENANCE Form I-SC (05-15) Obsoletes Form I-SC (12-14) INSTALLATION / OPERATION / MAINTENANCE Applies to: Model SC, Separated-Combustion Duct Furnace Model SC CUSTOMER CQS AGENCY CONVERGENT QUALITY SYSTEM PRODUCT

More information

INSTALLATION GUIDE Dual Fuel Ranges

INSTALLATION GUIDE Dual Fuel Ranges INSTALLATION GUIDE Dual Fuel Ranges Contents Wolf Dual Fuel Ranges......................... 3 Safety Instructions............................ 4 Dual Fuel Range Specifications.................. 5 Dual Fuel

More information

System Control. Installation, Operation & Service Manual WARNING. Installer

System Control. Installation, Operation & Service Manual WARNING. Installer System Control Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation,

More information

Series AM Infrared Heater Installation, Operation and Service Instructions

Series AM Infrared Heater Installation, Operation and Service Instructions Series AM Infrared Heater Installation, Operation and Service Instructions FOR YOUR SAFETY If you smell gas: 1. Open windows 2. Don t touch electrical switches 3. Extinguish any open flame 4. Immediately

More information

CTU Unit Heaters. Installation, Commissioning, Operation & Service Manual. Model CTU 22 to 115. Quality in Any Language Copyright 2003 Roberts-Gordon

CTU Unit Heaters. Installation, Commissioning, Operation & Service Manual. Model CTU 22 to 115. Quality in Any Language Copyright 2003 Roberts-Gordon FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Leave the building. 6. Immediately

More information

INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single Stage Push Through System (Positive Pressure) Models:

INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single Stage Push Through System (Positive Pressure) Models: INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single Stage Push Through System (Positive Pressure) Models: (Hot Rolled Steel) (Aluminized Steel) PCS 75 PCA 75 PCS 100 PCA

More information

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS Models: LRU5, LRU5, LRU0, LRU5, LRU0, LRU5, LRL5, LRL5, LRL0, LRL5, LRL0, LRL5 Single Stage Pull Through System (Negative Pressure)

More information

COMBUSTION RESEARCH CORPORATION

COMBUSTION RESEARCH CORPORATION COMBUSTION RESEARCH CORPORATION FOR YOUR SAFTEY If you smell gas:. Open windows 2. DO T try to light any appliance 3. DO T use electrical switches 4. DO T use any telephone in your building 5. Leave the

More information

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G PGM-1 Cooktops For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G Install ation Instructions Part No. 65476 Rev. B Table of Contents Appliance Safety...1 Important Safety Instructions...2

More information

DX SERIES TUBE HEATER

DX SERIES TUBE HEATER DX SERIES TUBE HEATER INSTALLATION, OPERATION, MAINTENANCE AND PARTS MANUAL Detroit Radiant Products Company FOR YOUR SAFETY! IF YOU SMELL GAS: 1. Open windows. 2. Do not touch electrical switches. 3.

More information

Owner s Guide Installation & Operation

Owner s Guide Installation & Operation Owner s Guide Installation & Operation Hot Top HHT Series Hestan Commercial Corporation 3375 E. La Palma Ave Anaheim, CA 92806 (888) 905-7463 RETAIN THIS MANUAL FOR FUTURE REFERENCE P/N 002130 REV 1 IMPORTANT

More information

Series LA/LX/LXR Infrared Heater Installation, Operation and Service Instructions

Series LA/LX/LXR Infrared Heater Installation, Operation and Service Instructions Series LA/LX/LXR Infrared Heater Installation, Operation and Service Instructions FOR YOUR SAFETY If you smell gas: 1. Open windows 2. Don t touch electrical switches 3. Extinguish any open flame 4. Immediately

More information

Series MA/MX/MXR Infrared Heater Installation, Operation and Service Instructions

Series MA/MX/MXR Infrared Heater Installation, Operation and Service Instructions Series MA/MX/MXR Infrared Heater Installation, Operation and Service Instructions FOR YOUR SAFETY If you smell gas: 1. Open windows 2. Don t touch electrical switches 3. Extinguish any open flame 4. Immediately

More information

INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS Form SQ-IOM-7 6000 SQS/U SYSTEMS GAS-FIRED LOW-INTENSITY INFRARED TUBE HEATERS SERIES: A, B, MB, and C INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS! WARNING! Improper installation, adjustment, alteration,

More information

PH Series Manual WARNING. Detroit Radiant Products Co. Installation, Operation, Maintenance and Parts. For Your Safety

PH Series Manual WARNING. Detroit Radiant Products Co. Installation, Operation, Maintenance and Parts. For Your Safety Detroit Radiant Products Co. PH Series Manual Installation, Operation, Maintenance and Parts All persons involved with the installation, operation and maintenance of the heater system must read and understand

More information

WARNING WARNING. 7D837A thru 7D849A, 7D851A, 7AR79 thru 7AR88. Installation, Operation, Maintenance, and Parts Manual

WARNING WARNING. 7D837A thru 7D849A, 7D851A, 7AR79 thru 7AR88. Installation, Operation, Maintenance, and Parts Manual Installation, Operation, Maintenance, and Parts Manual Please read and save these instructions. This heater must be installed and serviced by trained gas installation and service personnel only! Read carefully

More information

SERIES UA UXR. Installation, Operation and Service Instructions. Single Stage FOR YOUR SAFETY CONSIGNES DE SECURITE CONSIGNES DE SECURITE

SERIES UA UXR. Installation, Operation and Service Instructions. Single Stage FOR YOUR SAFETY CONSIGNES DE SECURITE CONSIGNES DE SECURITE Single Stage SERIES UA UX UXR Installation, Operation and Service Instructions WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death.

More information

CORAYVAC Helps Reduce Energy Bills and Improve Comfort

CORAYVAC Helps Reduce Energy Bills and Improve Comfort CORAYVAC Helps Reduce Energy Bills and Improve Comfort CORAYVAC gas-fired, low-intensity, infrared heating systems help provide custom comfort, while facilitating reduced energy consumption up to 50% and

More information

DTHS SERIES TUBE HEATER INSTALLATION, OPERATION MAINTENANCE AND PARTS MANUAL. Detroit Radiant Products Company FOR YOUR SAFETY!

DTHS SERIES TUBE HEATER INSTALLATION, OPERATION MAINTENANCE AND PARTS MANUAL. Detroit Radiant Products Company FOR YOUR SAFETY! DTHS SERIES TUBE HEATER INSTALLATION, OPERATION MAINTENANCE AND PARTS MANUAL Detroit Radiant Products Company FOR YOUR SAFETY! IF YOU SMELL GAS: 1. Open Windows. 2. Do not touch electrical switches. 3.

More information

Installation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365

Installation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365 Distinctive Electric Cooktop Models DECT304, DECT365 Installation Instructions 105643 Rev. A Françis : voir page 11 Español: consulte la página 21 Table of Contents Page Special Warnings... Product Dimensions

More information

Model VPT 120V 60Hz Gas-Fired, Tubular, Radiant, Low-Intensity Infrared Heater

Model VPT 120V 60Hz Gas-Fired, Tubular, Radiant, Low-Intensity Infrared Heater INSTALLATION / OPERATION / MAINTENANCE Applies to: Model VPT 120V 60Hz Gas-Fired, Tubular, Radiant, Low-Intensity Infrared Heater Model VPT High/Low Burner/Control Box with 20-70 ft Tube/Reflector Length

More information

INFRARED RADIANT TUBE HEATER RSTP15C NATURAL GAS RSTP17C

INFRARED RADIANT TUBE HEATER RSTP15C NATURAL GAS RSTP17C PROJECT: INFRARED RADIANT TUBE HEATER RSTP15C NATURAL GAS (CHECK ONE) RSTP17C NAME: ADDRESS: (CHECK ONE) PROPANE GAS DATE: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY: NAME: ADDRESS: NAME: ADDRESS: EQUIPMENT

More information

INSTALLATION GUIDE. For help, call BIG-FANS or visit

INSTALLATION GUIDE. For help, call BIG-FANS or visit For help, call 1-877-BIG-FANS or visit www.bigassfans.com INSTALLATION GUIDE Installation Checklist Do you have the correct power circuit for the fan speed control? (See p. 38 for information on selecting

More information

Quad Tube Heaters WARNING WARNING. Installation, Operation, Maintenance and Parts Manual

Quad Tube Heaters WARNING WARNING. Installation, Operation, Maintenance and Parts Manual Installation, Operation, Maintenance and Parts Manual Please read and save these instructions. This heater must be installed and serviced by trained gas installation and service personnel only Read carefully

More information

operating, installation and service manual

operating, installation and service manual MODELS: ULN80-125 ULN80-165 ULN80-180 ULN80-199 ULN100-199 ULN100T - 199 ULN100-250 ULN100-270 ULN100-300 ULN80-365 ULN80-399 ULN80-512 operating, installation and service manual Commercial Gas Water Heater

More information

Series UAB Infrared Heater

Series UAB Infrared Heater Series UAB Infrared Heater Installation, Operation and Service Instructions FOR YOUR SAFETY If you smell gas: 1. Open windows 2. Don t touch electrical switches 3. Extinguish any open flame 4. Immediately

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

Installation, Operation and Service Instructions H RANGE STANDARD EFFICIENCY HIGH INTENSITY HEATERS

Installation, Operation and Service Instructions H RANGE STANDARD EFFICIENCY HIGH INTENSITY HEATERS Installation, Operation and Service Instructions H RANGE STANDARD EFFICIENCY HIGH INTENSITY HEATERS WARNINGS WARNING Improper installation, adjustment, alteration, service or maintenance can cause property

More information

Installation Instructions Dual Fuel Ranges

Installation Instructions Dual Fuel Ranges Installation Instructions Dual Fuel Ranges E30DF74EPS E36DF76EPS E48DF76EPS 5995447082 2 Safety IMPORTANT SAFETY INSTRUCTIONS Safety Precautions Do not attempt to install or operate your unit until you

More information

Installation / Operation. Applies to: Standard Power Vent Unit Heaters: Separated Combustion Unit Heaters:

Installation / Operation. Applies to: Standard Power Vent Unit Heaters: Separated Combustion Unit Heaters: Document No D300519 (4-8-16) Obsoletes Document No D300519 (04-15) Installation / Operation Applies to: Standard Power Vent Unit Heaters: Separated Combustion Unit Heaters: NOTE: Accessories referenced

More information

GAS COOKTOP INSTALLATION INSTRUCTIONS

GAS COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. WARNING If the information

More information

12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker.

12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker. Installation Manual For 1200ACXX models: For 120XAC-IMXX models: 12.0 cu.ft., 2-way, 4-door, R.V. refrigerator. 12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker. The letter X, in the model

More information

Owner s Information Manual

Owner s Information Manual 48ES---A and 48VL---A Comfort and Performance 13 and 14 SEER Single Packaged Air Conditioner and Gas Furnace System With Puron (R---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60)

More information

Owner s Guide Installation & Operation

Owner s Guide Installation & Operation Owner s Guide Installation & Operation Char Broiler HCH Series Hestan Commercial Corporation 3375 E. La Palma Ave Anaheim, CA 92806 (888) 905-7463 RETAIN THIS MANUAL FOR FUTURE REFERENCE P/N 002134 REV

More information

STERLING RSS SERIES INFRARED RADIANT TUBE HEATER

STERLING RSS SERIES INFRARED RADIANT TUBE HEATER RSUS-1 RSS 40-200 SERIES (Check One) RSU 40-200 SERIES NATURAL GAS (Check One) PROPANE GAS STANDARD CONSTRUCTION ALC CONSTRUCTION (All Heat Treated Emitter Tubes) SINGLE STAGE TWO STAGE EQUIPMENT USED:

More information

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY Form CP-F/B-GC (Version A) Obsoletes Form CP-F/B-GC Gas Conversion Kits and Instructions Applies to: Models F, B, FE, and BE Model B Model F All gas conversion must be done by a qualified service person

More information