SPME-FFA Field Sampler

Size: px
Start display at page:

Download "SPME-FFA Field Sampler"

Transcription

1 Page 16 SPME-FFA Field Sampler Manual Page 1 Cat.No U CHROMLINE Via Anita Garibaldi, Prato (PO) Italy Phone: Fax: info@chromlinesrl.com web: CHROMLINE SRL. Printed in Italy. Version 1.4 Chromline Srl Via Anita Garibaldi, Prato (PO) Italy Phone: FAX: info@chromlinesrl.com web:

2 Page 2 Page 15 REPLACEMENT PARTS & ACCESSORIES IMPORTANT NOTE This holder accepts only SPME Fast Fit Assemblies (FFA). Standard SPME ibers do not work and can be damaged when attempted to be used with this holder. Products included with U: 1x SPME-FFA Field Sampler 1x Plunger Recovery Tool 1x Needle Septa 5x3mm 1x Stainless Steel Needle Guide 1x PTFE Sealing Cup 23ga Blunt Tip Fibers one notch 1x PTFE Sealing Cup 24ga Blunt Tip Fibers two notches 1x PTFE Sealing Cup 23ga Bevel Tip fibers no notch FFA Fibers FFA57293-U FFA57327-U FFA57298-U FFA57329-U FFA57341-U FFA57301 FFA57294-U FFA57305 FFA57295-U FFA57335-U FFA57354-U FFA57309 FFA57302 FFA57289-U FFA57291-U PK3, 65μm PDMS-DVB Stableflex SPME Fast Fit Assembly 23ga PK3, 65 μm PDMS-DVB Stableflex SPME Fast Fit Assembly 24 ga PK3, 50/30 μm DVB/CAR/PDMS Stableflex SPME Fast Fit Assembly 23 ga PK3, 50/30 μm DVB/CAR/PDMS Stableflex SPME Fast Fit Assembly 24 ga PK3, 100 μm PDMS SPME Fast Fit Assembly 23 ga PK3, 100 μm PDMS SPME Fast Fit Assembly 24 ga PK3, 85 μm POLYACRYLATE SPME Fast Fit Assembly 23 ga PK3, 85 μm POLYACRYLATE SPME Fast Fit Assembly 24 ga PK3, 85 μm CAR/PDMS STABLEF. SPME Fast Fit Assembly 23 ga PK3, 85 μm CAR/PDMS STABLEF. SPME Fast Fit Assembly 24 ga PK3, 60 μm PEG Metal SPME Fast Fit Assembly 23 ga PK3, 30 μm PDMS SPME Fast Fit Assembly 24 ga PK3, 7 μm PDMS SPME Fast Fit Assembly 24 ga PK3, 30 μm PDMS SPME Fast Fit Assembly 23 ga PK3, 7 μm PDMS SPME Fast Fit Assembly 23 ga INDEX INTRODUCTION 3 SPME-FFA FIELD SAMPLER PARTS 4 ACCESSORIES 5 INSTALLATION OF PTFE SEALING CUP, SEPTA, AND FFA 6 SAMPLING 8 CLEANING OF FIELD SAMPLER 9 DESORPTION MANUAL & AUTOMATED BY MFX 10 APPENDIX PTFE SEALING DATA 12 TROUBLE SHOOTING RECOVERY OF INNER PLUNGER 14 REPLACEMENT PARTS 15 PTFE Sealing System & Septa U PK3, PTFE sealing cups 23ga beveled no identification line (SFSC23BE) U PK3, PTFE sealing cups 23ga blunt one identification line (SFSC23BL) U PK3, PTFE sealing cups 24ga blunt two identification lines (SFSC24BL) U Needle Septa, Pk3. (RSS000E) Replacement Parts U Stainless steel needle guide (SFSC000A) U FFA-FS O-ring kit (RSS000D) U FFA-FS Needle protector (RSS000C) U FFA-FS Sampler body screw (RSS004) U FFA-FS Needle septa nut (RSS005) U FFA-FS Sealing mechanism with plunger end cap (RSS000B) U FFA-FS Plunger cap (RSS010) Accessories U FFA-FS manual desorption adapter (RSS000F) U Plunger Recovery Tool (RSS000H) U Station for Needle Protector Removal (RSS000G) U SPME FFA Storage Container

3 TROUBLE SHOOTING Page 14 SPME-FFA Field Sampler (FFA-FS) Page 3 RECOVERY OF INNER PLUNGER In case the inner plunger gets accidentally pushed in without having the external plunger properly installed, the enclosed plunger recovery tool can be used to pull the inner plunger Fig. 29 Inner plunger accidentially pressed in Fig. 30 Plunger recovery tool. Fig. 31 Insert the tool to retrieve the inner plunger STATION FOR NEEDLE PROTECTOR REMOVAL (57583-U) When the needle protector of the FFA-FS has gotten contaminated it can be removed by using the Needle Protector Removal Station. Affix the station e.g. on table or on an instrument using the screw holes H1 and H2 (screws not included). Insert the needle into the station and unscrew the part. Now you can inject the sample without touching the contaminated part. The SPME-FFA Field Sampler (FFA-FS) is designed to be used with SPME Fast Fit fiber Assemblies (FFAs). It is suitable for various kinds of field sampling applications by exposing the installed fiber to the environment to be sampled. The sampler is selfcontained and allows safe storage of a conditioned or sampled SPME fiber (only SPME FFA). The plunger assembly in this holder works as an actuator to expose the fiber but also incorporates a sealing mechanism to safely transport the conditioned or sampled fiber from and/or to the laboratory. This allows the user to prepare and set up the sampler in a clean environment (e.g. laboratory). At the sampling site the user just needs to remove the plunger/protection and expose the fiber to the environment. Only the needle part of the SPME FFA gets into contact with the sampled environment. The rest of the FFA stays sealed off in the holder until removal from the sampler. After sampling the plunger with its sealing mechanism/ protection serves to safely store and transport the sampled fiber until analysis. Alternatively the FFA can be removed from the field sampler and be placed in an optional SPME FFA Storage Container (Cat.No U). Desorption of the sampled FFA into the GC instrument can be done manually with the FFA-FS using an optional desorption adapter (Cat.#57568-U) or by placing the FFA into a Multi Fiber Exchanger System (MFX)* suitable for CTC Combipal Type autosampler. The MFX system is available as 3-Pos. and 25-Pos. System (45-Pos. as custom). Please see also page 11 in this manual. H2 H1 Fig Station for needle protector removal. Fig Double plain face of needle protector as seat for wrench or removal station References: Anal. Chem 2000, 72, Koziel, J.; Jia, M.; Pawliszyn, J. Air Sampling with Porous Solid Phase Microextraction Fibers * available from Gerstel GmbH & Co KG

4 Page 4 Page 13 FIELD SAMPLER PARTS Plunger Recovery Tool Manual Desorption Adapter (Optional Accessory) Sampler Body Screw (Part F) (RSS004) Needle Septa Sampler Body Name Conc. (mg/m 3 ) in Tedlar bag 25 L % Loss after C RSD% (n=5) % Loss after 15 Room Temp.( C) RSD% (n=5) % Loss after C Dichloromethane 16,625-6,9 6,6-4,6 7,9-11,3 8,2 MTBE 9,25-2,8 9,8-7,2 4,3-4,3 9,2 n-hexane 8,25-4,3 8,7-8,1 4,6-6,1 6,7 RSD% (n=5) PTFE Sealing Cups (Part B) Plunger Cap(Part A1) (RSS010) SS Needle Guide (Part C) Septa Nut (Part E) (RSS005) Needle Protector (RSS000C) Plunger (RSS003) Sealing Assembly/Unit with Plunger Cap (Part A) (RSS000B) 1,1,1 Trichloroethane 16,75-4,9 6,2-1,4 8,6-3,5 9,7 1,2 Dichloroethane 15,625-3,9 9,3-6,3 4,1-7,3 4,5 Benzene 11-5,3 4,1-6,7 4,1-5,5 6,2 Trichloroethylene 18,25-6,1 6,6-4,5 8,6-4,8 7,5 Toluene 10,875-4,7 6,8-7,8 6,5-6,3 2,9 Tetrachloroethylene 20,25-4,2 7,4-3,1 7,3-3,3 8,1 Ethylbenzene 10,875-5,5 5,3-5,7 4,5-6,1 5,0 m + p Xylene 10,75-5,1 3,7-4,0 7,5-4,9 5,5 o-xylene 11-4,8 6,1-6,8 4,6-6,2 3,5 1,3,5 Trimethylbenzene 10,875-3,5 8,8-4,3 5,5-5,9 5,4 1,2,4 Trimethylbenzene 10,875-5,6 6,3-5,1 4,5-5,5 8,3 Fig. 1 - FFA-Field Sampler(FS) Parts Fig. 2 Plunger recovery tool. (Cat.# U). Fig. 3 - Needle Septa 5x3 mm (Cat.# U). Optional FFA Storage PTFE Sealing Cups & Needle Guide B1 Fig. 4 - for 23ga beveled tip fibers no identification notch (Cat# U). B3 Fig. 6 - for 24ga blunt tip fibers two identification notches (Cat# U). After sampling, the FFA can also removed from the field sampler and be stored in an optional FFA Storage Container (57592-U). This storage container is employing the same PTFE sealing mechanism. B2 Fig. 5 - for 23ga blunt tip fibers one identification notch (Cat# U). Fig. 7 - Stainless steel Needle Guide. (Cat# U).

5 PTFE SEALING UP DATA Page 12 The Chromline sealing mechanism ensures integrity of fiber conditioning as well as enabling storage of the sampled fiber. Below chromatograms show a cleaned fiber immediately desorbed and after conditioning (Fig. 38) and after15 days sealed with the PTFE Sealing Cap used in the FFA-FS (Fig. 39). The sealed fibers were exposed to the atmosphere below mentioned compounds and concentrations. No contamination could be observed in that time. With the same test set up the storage stability of a sample was evaluated for the same mix of VOCs at different tempratures was evaluated. Temperatures was -4 C, room temperature ( C) and +40 C. The test was done with 85μm CAR/PDMS 23ga fiber (the same fibers were used for each temperature). For sampling the fibers were exposed 15 sec to the atmosphere of compounds mentioned in below table. For details on this study please contact Chromline under info@chromlinesrl.com. ACCESSORIES Fig. 8 - FFA-FS manual desorption adapter (Cat.# U). Page 5 Fig. 9 - Optional station for convenient Needle Protector removal (Cat.# U). SPME-FFA to be used in this Field Sampler Fig Fiber after conditioning. Fig SPME-FFA. The SPME Fast Fit Assemblies (FFA) are a configuration of SPME fibers allowing the automated exchange of SPME fibers by the Multi Fiber EXchange (MFX) system on an autosampler. For the most recent listing of products, please refer to sigma-aldrich.com/spme FFA Barcode Labeling Provides the user and the autosampler with information about the properties of the SPME fast fit fiber assembly: A. The color code indicates the phase type. The coding is the same as for the colored screw hub of the traditional SPME fiber assemblies B. The first 2 digits of the barcode identify the fiber type, incorporating the phase and the gauge size. C. The remaining digits represent a unique tracking number for sample traceability. Fig Fiber after15 days sealed by Chromline PTFE sealing cup.

6 Page 6 Page 11 PTFE SEALING CUP INSTALLATION AUTOMATIC DESORPTION WITH MFX Part A Part A Fig Open FS plunger assembly by unscrewing the sealing assembly (Part A) Fig Sealing assembly out of plunger (Part A). Fig. 33 For automated desorption open FFA-FS to remove FFA. Fig Place the FFA fiber in MFX tray. Part B1 23ga bev. Part B2 23ga bl. Part B3 24ga bl. Part C Fig Chose PTFE cap (Part B1, B2, B3) according to SPME needle being used. See page 5 for details. Fig Assemble parts A,B (B1, B2 or B3) and C. Fig Re-install Part A into the plunger assembly Fig SPME Fiber Saver on the MFX tray keep the fibers sealed before being analyzed. Fig MFX tray with 25 FFA positions. A MFX with 3 positions is available and as custom one with 45 positions Fig Example set up: GERSTEL MPS autosampler with MFX 3-Position option on Agilent Technologies GC7890+ MSD. MFX System For more information on the Multi Fiber EXchanger System please refer to the Gerstel website: Data on PTFE sealing efficiency can be found in the Appendix.

7 MANUAL DESORPTION Page 10 INSTALLATION OF NEEDLE SEPTA Page 7 By installing the manual desorption adapter for the FS (Cat.# U) sampled fibers can directly be inserted into a GC injector block for desorption. Remove plunger and install as described in Fig Part E Fig Remove the needle protection by unscrewing it from the sampler and attach the manual desorption adapter to the FS as indicated below. Install the plunger as described in Fig 23. Part E Fig Unscrew Septa Nut (Part E). Fig Insert silicone septa into part E and re-install part E on the sampler FFA INSTALLATION Fig Inject the FFA needle into the GC injector port in a way that the adapter sits on the injector s septa screw. Make sure that the sampler does not tilt to prevent any needle bending. Push the plunger down to expose the fiber in the injector. The fiber is now getting desorbed. Fig After desorption retract the fiber into the needle by pulling the plunger back, then remove the sampler from the injector port. To ensure the fiber does not get contaminated place the plunger back over the needle protection like shown in Fig. 28. Fig FFA fiber. Part F Fig Take FS apart by unscrewing the sampler body screw (Part F) as indicated and place FFA into the left hand part first. Use gentle force to push the FFA needle through the septa. Optional pre-pierce the septa with a syringe needle. Note: Please refer to your GC instrument manual for the distance of the injector top to the hottest part of the injector block. The Manual desorption adapter (Cat.No U) is designed for an injection depth of 5 cm. Fig Re-assemble and tighten the FS. In this status the sampler can be transported to the sampling site maintaining the conditioning of the FFA.

8 SAMPLING Page 8 Page 9 Part A1 2 Part A1 1 Fig Remove plunger from holder (1). Detach plunger cap (Part A1) from the plunger by unscrewing it. 2 1 Fig Insert flat point of plunger in pos.1 and slide to pos. 2 to lock. Fig Insert plunger cap into the opening on the other end of the plunger for storage. Fig For sampling, press the plunger until you hear/feel a click. Fig Place the plunger back over the fiber protection for sealing. Fig The FS can now be stored until analysis. After sampling in contaminated environments it might be advisable to clean the sampler before further handling. CLEANING PROCEDURE Fig FFA-FS closed and ready for cleaning procedure. During sampling and when the sampler is closed, the inside part of the device is sealed off from the external environment. When the fiber is exposed, the movement of the plunger compresses the air inside the holder. There is no venting to the out side. By this, the interior of the sampler does not become contaminated when retracting the fiber. In case the sampling was done in a contaminated area, one can clean the device, e.g. with sodium hypochlorite solution. Testing by storing the sampler for 15 days in sodium hypochlorite solution showed no detrimental or negative effect on the integrity of the sampler. This test demonstrated the suitability of the sampler for use under extreme conditions. Fig The fiber is now exposed within the needle protector cage for sampling Fig To retract the fiber after sampling proceed in revese order (Fig.24 to 21. Pull the plunger and remove it. Optional FFA Storage After sampling, the FFA can also removed from the field sampler and be stored in an optional SPME-FFA Storage Container (57592-U)

Agilent GC Sampler 80/120 SPME Option

Agilent GC Sampler 80/120 SPME Option Agilent GC Sampler 80/120 SPME Option User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in any form or by any means (including electronic

More information

General Animal Injections

General Animal Injections Hamilton Company offers a wide variety of specialized syringes for life science applications. From custom needles to specialized animal injections and gel loading syringes, Hamilton has a solution for

More information

MultiPurpose Sampler MPS robotic series

MultiPurpose Sampler MPS robotic series MultiPurpose Sampler MPS robotic series sample prep for winners The MPS robotic efficiently and reliably automates sample preparation and sample introduction MPS robotic for GC and GC/MS Whether you are

More information

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process Save Hours in Sample Preparation Reduce the time to prepare and inject samples

More information

GC Injectors. GC Injectors

GC Injectors. GC Injectors SRI offers a wide variety of GC injectors and injection systems. Up to five injectors may be mounted simultaneously on the Model 8610C or 8610D. The Model 310 will accommodate a single On-column, Heated

More information

AppNote 6/2008. Automated SPE and Fast GC-ECD Analysis of PCBs in Waste Oil KEYWORDS ABSTRACT INTRODUCTION. MACH, Fast GC-ECD, SPE, PCB, waste oil

AppNote 6/2008. Automated SPE and Fast GC-ECD Analysis of PCBs in Waste Oil KEYWORDS ABSTRACT INTRODUCTION. MACH, Fast GC-ECD, SPE, PCB, waste oil AppNote 6/2008 Automated SPE and Fast GC-ECD Analysis of PCBs in Waste Oil Karine Jacq, Bart Tienpont, Frank David Research Institute for Chromatography, Pres. Kennedypark 26, B-8500 Kortrijk, Belgium

More information

TYPES AND APPROPRIATE INJECTORS

TYPES AND APPROPRIATE INJECTORS SRI offers a wide variety of GC injectors and injection systems. Up to five injectors may be mounted simultaneously on the Model 8610C or 8610D. The Model 310 will accommodate a single On-column, Heated

More information

Chromatography. Research Supplies. 2014/2015 Catalog

Chromatography. Research Supplies. 2014/2015 Catalog Chromatography Research Supplies 2014/2015 Catalog The CRS Commitment Service That Rev lves Around You! Our purpose at CRS is to meet our customer s requirements for quality, service, and value. Quality

More information

Introducing New 96-Well Fast Plate Adapters for Applied Biosystems Capillary Electrophoresis Systems

Introducing New 96-Well Fast Plate Adapters for Applied Biosystems Capillary Electrophoresis Systems User Bulletin ABI PRISM 310, 3100 & 3100-Avant Genetic Analyzers, Applied Biosystems 3130 & 3130xl Genetic Analyzers, and Applied Biosystems 3730 & 3730xl DNA Analyzers August 2006 SUBJECT: Introducing

More information

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples Process and Air Monitoring Online GC systems for continuous monitoring of organic compounds in air and gaseous samples For 35 years AMA Instruments has developed and manufactured analytical devices and

More information

Aquamax KF Oil Evaporator. User Manual

Aquamax KF Oil Evaporator. User Manual Aquamax KF Oil Evaporator User Manual Edition 1.1 - April 2015 Contents Chapter 1 Introduction... 2 1.1 Instrument Description... 2 1.2 Principle of Measurement... 2 1.3 Instrument Connections... 2 Chapter

More information

INJECTORS Purge & Trap General Operating Procedures continued

INJECTORS Purge & Trap General Operating Procedures continued General Operating Procedures continued 1. Remove the 6 screws that secure the bottom panel to the rest of the GC chassis. Support the panel while you gently rock the GC onto its back, then lower the panel

More information

Purge and Trap Troubleshooting Made Easy?

Purge and Trap Troubleshooting Made Easy? Purge and Trap Troubleshooting Made Easy? Tyler Trent- Application Chemist Preston Hoppes- International Tech Support/FSE Tammy Rellar- Application Sales Specialist Teledyne Tekmar Purge and Trap Troubleshooting

More information

original your automatic choice Socorex The Socorex original models Twin syringe = extended programme

original your automatic choice Socorex The Socorex original models Twin syringe = extended programme Socorex original your automatic choice animal health > veterinary > vaccination > injection syringes The Socorex self-refilling syringes with spring-loaded plunger and threeway valve system are designed

More information

Operating Instructions

Operating Instructions Operating Instructions NVI-570V Automatic Injector Catalog No. 65-0033 Harvard Apparatus, Inc. 84 October Hill Road Holliston, Massachusetts 01746 Toll Free: (800) 232-2380 Fax: (508) 429-5732 1 PACKING

More information

Agilent 1290 Infinity II Online SPE Solution

Agilent 1290 Infinity II Online SPE Solution Agilent 1290 Infinity II Online SPE Solution Instruction Agilent Online-SPE-Solution - Instruction Technical Information about the Agilent Online-SPE-Solution (optional setups with: G4242A Online-SPE Starter

More information

ZD-985 Desoldering Station

ZD-985 Desoldering Station ZD-985 Desoldering Station 2 Contents Contents... 3 Unpacking and Setting Up Your ZD-985 Desoldering Station... 4 Setting Up the Unit... 5 Auto Tip Saver Function... 8 Tips and Techniques... 8 Alloy Melt

More information

Air Server & Multi Channel Samplers (MCS06 & MCS08)

Air Server & Multi Channel Samplers (MCS06 & MCS08) Air Server & Multi Channel Samplers (MCS06 & MCS08) Operators Manual AUGUST 2006 QUI-0004 VERSION 6.1 Ltd. T: +44 (0)1443 230935 F: +44 (0)1443 231531 E: enquiries@markes.com This page left intentionally

More information

Fisher Scientific Isotemp Muffle Furnace 550 Series. Instruction Manual

Fisher Scientific Isotemp Muffle Furnace 550 Series. Instruction Manual Fisher Scientific Isotemp Muffle Furnace 550 Series Instruction Manual Model 14 Catalog No: 10-550-14 & 14A Model 58 Catalog No: 10-550-58 Model 126 Catalog No: 10-550-126 Service Division (Repairs):

More information

ACME DIAGNOSTICS STANDARD OPERATING PROCEDURE

ACME DIAGNOSTICS STANDARD OPERATING PROCEDURE ACME DIAGNOSTICS STANDARD OPERATING PROCEDURE Procedure Number: II.01.200a Effective Date: 09/14/99 Review and Update: 09/2003 TITLE: ADVIA 120 ROUTINE MAINTENANCE PURPOSE AND PRINCIPLE: The ADVIA 120

More information

CALIDUS tm the Modular micro Gas Chromatograph

CALIDUS tm the Modular micro Gas Chromatograph CALIDUS tm the Modular micro Gas Chromatograph Sample Processing Unit Plug & Play Programmed Temperature Column Modules Plug & Play Detector Modules Flame Ionization Thermal Conductivity A CALIDUS micro

More information

Perkin Elmer Clarus 500 Gas Chromatograph

Perkin Elmer Clarus 500 Gas Chromatograph IET International Equipment Trading, Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Perkin Elmer Clarus 500 Gas Chromatograph

More information

High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity

High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity High Volume Injection up to ml with the Agilent 00 Infinity Series Online SPE Solution for Highest Sensitivity Technical Overview Author Bettina Schuhn Agilent Technologies, Inc. Waldbronn, Germany Abstract

More information

Automação de SPE utilizando sistema robótico Triplus RSH autosampler. Nova Analitica

Automação de SPE utilizando sistema robótico Triplus RSH autosampler. Nova Analitica Automação de SPE utilizando sistema robótico Triplus RSH autosampler Nova Analitica ITSP Introduction The heart of the ITSP system is a patented cartridge containing customer-defined filter and/or SPE

More information

Instructions for CO 2 Cold Trap System. Part No

Instructions for CO 2 Cold Trap System. Part No Instructions for CO 2 Cold Trap System Part No. 093346 Introduction Congratulations on your purchase of the SGE CO 2 Cold Trap System. Please take time to read the instructions in this manual carefully

More information

300 series HPLC autosamplers

300 series HPLC autosamplers 300 series HPLC autosamplers issue 1 Automated HPLC Sampling Manual HPLC sampling can be very difficult and time consuming......hta s range of HPLC autosamplers can perform HPLC sample preparation and

More information

The Complete and Easy Guide to Configuring Your Specific Thermo NanoLC for Mass Spec Analysis

The Complete and Easy Guide to Configuring Your Specific Thermo NanoLC for Mass Spec Analysis The Complete and Easy Guide to Configuring Your Specific Thermo NanoLC for Mass Spec Analysis September 2013, Version 2 The world leader in serving science Content Selection Tree EASY-nLC 1000 Slide 3

More information

Agilent InfinityLab Online SPE Solution

Agilent InfinityLab Online SPE Solution Agilent InfinityLab Online SPE Solution Instruction Agilent Online SPE Solution - Instruction Technical Information about the Agilent InfinityLab Online SPE Solution. The following possible set-ups are

More information

HEATING AND AIR CONDITIONING

HEATING AND AIR CONDITIONING XJ HEATING AND AIR CONDITIONING 24-1 HEATING AND AIR CONDITIONING TABLE OF CONTENTS page DESCRIPTION AND OPERATION SERVICE WARNINGS AND PRECAUTIONS...1 COMPRESSOR - 2.5L VM DIESEL....3 COMPRESSOR CLUTCH

More information

Electron Microscopy Sciences

Electron Microscopy Sciences Electron Microscopy Sciences INSTRUCTIONAL MANUAL CAT. 71260-10 through 71260-17 Cabinet Style Lab Companion Vacuum Desiccators sgkcck@aol.com P.O. Box 550, 1560 Industry Road, Hatfield, PA 19440 Safety

More information

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC. Fig. 2: Blower & Evaporator Unit Specifications 2004 HVAC SYSTEMS Manual HVAC System - Sorento GENERAL SPECIFICATIONS AIR CONDITIONER Fig. 1: Air Conditioner Specifications BLOWER AND EVAPORATOR UNIT HEATER

More information

TK-1001, 1101, 1201, 1301, 1601

TK-1001, 1101, 1201, 1301, 1601 TK-1001, 1101, 1201, 1301, 1601 Pneumatic Room Thermostats General Instructions DEVICE INFORMATION Identification Thermostats of this family may be easily identified by referring to the part number located

More information

Q Trap LC/MS/MS TurboIonSpray Ion Source Manual. About This Manual... 1 Conventions Introduction... 3 Features... 4

Q Trap LC/MS/MS TurboIonSpray Ion Source Manual. About This Manual... 1 Conventions Introduction... 3 Features... 4 Q Trap LC/MS/MS TurboIonSpray Ion Source Manual Table of Contents Table of Contents About This Manual................................................ 1 Conventions.........................................................

More information

Raffaello From serial number Group

Raffaello From serial number Group Group 1 C199900260 Solenoid valve V.230/50-60 1 C199900261 Solenoid valve, V. 115/60 2 C449900786 O-Ring 3 C229900553 Nut 4 C449900079 O-Ring 5 C619900554 Metal filter 6 C229900549 Gigleur 7 C229900674

More information

Preparing the 6850 Series II GC for 597x MSD Installation

Preparing the 6850 Series II GC for 597x MSD Installation Preparing the 6850 Series II GC for 597x MSD Installation Agilent 6850 Series II Network GC System This installation sheet documents the procedures needed to prepare the 6850 Series II GC for 597x MSD

More information

UNITY 2 TM. Air Server Series 2 Installation Manual. Version September 2012

UNITY 2 TM. Air Server Series 2 Installation Manual. Version September 2012 UNITY 2 TM Air Server Series 2 Installation Manual Version 1.12 September 2012 1. Installation...2 1.1. Tools required...2 1.2. Procedure...2 1.3. Requirement for a sample pump (U-ASPMP1 / U-ASPMP2)...8

More information

Thermo Scientific. TRACE GC Ultra. Gas Chromatograph Maintenance and Troubleshooting Manual. PN , Revision March 2011

Thermo Scientific. TRACE GC Ultra. Gas Chromatograph Maintenance and Troubleshooting Manual. PN , Revision March 2011 Thermo Scientific TRACE GC Ultra Gas Chromatograph Maintenance and Troubleshooting Manual PN 31709180, Revision March 2011 TRACE GC Ultra Maintenance and Troubleshooting Manual March 2011 Edition Original

More information

McNeil Group University of Michigan. MBraun Glovebox. Preparing Items To Be Brought Into the Glovebox

McNeil Group University of Michigan. MBraun Glovebox. Preparing Items To Be Brought Into the Glovebox MBraun Glovebox Preparing Items To Be Brought Into the Glovebox Equipment Glassware, stirbars, needles, spatulas and pretty much anything that can go in the oven: should be dried in the oven for at least

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Italy - DE112/0404 Oil burners fuel unit with solenoid valve Type VM The DELTA

More information

Indirect Cryogenic Cold Trap System Instructions

Indirect Cryogenic Cold Trap System Instructions www.sge.com Indirect Cryogenic Cold Trap System Instructions Part Number: 0933451 1.0 INTRODUCTION Congratulations on your purchase of the SGE Indirect Cryogenic Cold Trap System. Please take time to carefully

More information

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier Operating Manual Incl. EU Declaration of Conformity Vacuum Switch, Differential Pressure Adapter, Switching Amplifier VSC150, SV tina42e1-b (2017-03) 1 Product Identification In all communications with

More information

2006G2 OPERATING INSTRUCTIONS. 2006G2 Pressure-Vacuum Hand Pump July 2011 SOILMOISTURE

2006G2 OPERATING INSTRUCTIONS. 2006G2 Pressure-Vacuum Hand Pump July 2011 SOILMOISTURE OPERATING INSTRUCTIONS 2006G2 Pressure-Vacuum Hand Pump July 2011 2006G2 1 TABLE OF CONTENTS UNPACKING...1 ACQUAINT YOURSELF WITH THE PARTS...1 REMOVAL OF AIR FROM TENSIOMETERS...2 PULLING A VACUUM IN

More information

A Issue 3. USA Distributor:

A Issue 3. USA Distributor: 2 USA Distributor: 3 4 5 6 Table of Contents COMPANY INFORMATION...3 Contact Addresses...3 SAFETY INFORMATION...4 GENERAL SAFETY...4 SYMBOLS...5 CHEMICAL SAFETY...6 ENVIRONMENT...6 WARRANTY STATEMENT...6

More information

Filtering Division. Dust collectors. MIX S.r.l. MIXING SYSTEMS AND COMPONENTS FOR PLANTS ATEX-RATED PRODUCTS AVAILABLE CF/162

Filtering Division. Dust collectors. MIX S.r.l. MIXING SYSTEMS AND COMPONENTS FOR PLANTS ATEX-RATED PRODUCTS AVAILABLE CF/162 MIX S.r.l. MIXING SYSTEMS AND COMPONENTS FOR PLANTS www.mixitaly.com Filtering Division Dust collectors ATEX-RATED PRODUCTS AVAILABLE CF/162 EN COPYRIGHT 2016 BY MIX S.r.l. Quality and Innovation AIR POLLUTION

More information

Avensys Avensys FIN EST SLO RUS UAE

Avensys Avensys FIN EST SLO RUS UAE 34 039 Avensys Avensys GB D...1...5 I...5 N...9 GR...13 TR...17 BG...21 RO...25 GB...2 NL...6 FIN...10 CZ...14 SK...18 EST...22 CN...26 F...3 S...7 PL...11 H...15 SLO...19 LV...23 RUS...27 E...4 DK...8

More information

Operation Manual R205BV, R209BV

Operation Manual R205BV, R209BV Operation Manual R205BV, R209BV 1 Safety Instruction The rotary evaporator is manufactured according to current methods and accepted safety regulations. However, risks still exist during the installation,

More information

s y ens Av Avensys FIN EST RUS SLO RUS UAE

s y ens Av Avensys FIN EST RUS SLO RUS UAE 34 224 34 225 Avensys Avensys GB D...1...5 I...5 N...9 GR...13 TR...17 BG...21 RO...25 GB...2 NL...6 FIN...10 CZ...14 SK...18 EST...22 RUS CN...26 F...3 S...7 PL...11 H...15 SLO...19 LV...23 RUS...27 E...4

More information

Systems. Visit us at

Systems. Visit us at Systems And especially: SPE Module Visit us at www.lctech.de! Systems General e Description Highlights Modules Structure and Availability FREESTYLE TM BASIC FREESTYLE TM SPE 2 FREESTYLE General Description

More information

APPLICATION NOTE DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. APPLICATION NOTE As of July 2017, Version: 1.

APPLICATION NOTE DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. APPLICATION NOTE  As of July 2017, Version: 1. DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO 9377-2:2000 APPLICATION NOTE www.lctech.de As of July 2017, Version: 1.7 Keywords: DIN EN ISO 9377-2:2000, DEV H53; LAGA-Richtlinie KW/04 2009, Hydrocarbon

More information

Genuine Restek Replacement Parts for Agilent GCs

Genuine Restek Replacement Parts for Agilent GCs Genuine Restek Replacement Parts for Agilent GCs Chromatography Products 800-356-688 www.restek.com www.restek.com 800-356-688 84-353-300 From Injector to Detector Restek is your # source for consumables

More information

Datalogging as standard

Datalogging as standard Datalogging as standard for expanded performance Autofim II and Autofim II GC have a sophisticated datalogging system, as standard, which enables you to keep a permanent data record. The memory is capable

More information

HITACHI CHROMASTER. Clarity Control Module. Code/Rev.: M173/70I Date: 6/23/2018

HITACHI CHROMASTER. Clarity Control Module. Code/Rev.: M173/70I Date: 6/23/2018 HITACHI CHROMASTER Clarity Control Module ENG Code/Rev.: M173/70I Date: 6/23/2018 Phone: +420 251 013 400 DataApex Ltd. Fax: +420 251 013 401 Petrzilkova 2583/13 clarity@dataapex.com 158 00 Prague 5 www.dataapex.com

More information

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, SQUATTING TOILET. To main vacuum line, connection Ø50.

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, SQUATTING TOILET. To main vacuum line, connection Ø50. Date: 25 Jan 2005 Doc. 1:114E TECHNICAL DATA 5979301 EVAC 90, SQUATTING To main vacuum line, connection Ø50 Service door 600 Push button Fresh water supply connection 1/2" MPT BSP 700 700 Flushing mechanism

More information

ASPIRE Laboratory Aspirator

ASPIRE Laboratory Aspirator ASPIRE Laboratory Aspirator USER MANUAL Rev 2/14/18 Accuris Instruments / Benchmark Scientific Ph: (908) 769-5555 E-mail: info@accuris-usa.com (C) Benchmark Scientific, 2018 THE ACCURIS ASPIRE LABORATORY

More information

High Pressure Manways CODAP 2000 & PED 96/23/CE

High Pressure Manways CODAP 2000 & PED 96/23/CE High Pressure Manways CODAP 2000 & PED 96/23/CE Alchem offer a range of High-Pressure manways designed and built to comply with the European Pressure Directive 97/23/CE and also with the pressure vessel

More information

API 2000 LC/MS/MS TurboIonSpray Ion Source Manual

API 2000 LC/MS/MS TurboIonSpray Ion Source Manual Table of Contents API 2000 LC/MS/MS TurboIonSpray Ion Source Manual Table of Contents API 2000 TurboIonSpray Ion Source Manual....1 AboutThisManual...1 Introduction...1 TurboIonSpraySourceComponents...3

More information

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System Simplicity Reliability Performance Stratum Automated VOC Sample Prep System The Stratum Purge and Trap Concentrator (PTC) is a sample preparation instrument used to remove Volatile Organic Compounds (VOCs)

More information

ACQUITY UPLC HT Column Heater Instructions

ACQUITY UPLC HT Column Heater Instructions ACQUITY UPLC HT Column Heater Instructions Note: This document is an addendum to Revision C of the ACQUITY UPLC System Operator s Guide. Contents: Topic Page Overview 1 Connecting the cable 4 Installing

More information

Field Validation of an On-Line FTIR Analyzer for Measuring Total Siloxane Content in Landfill Gas

Field Validation of an On-Line FTIR Analyzer for Measuring Total Siloxane Content in Landfill Gas Field Validation of an On-Line FTIR Analyzer for Measuring Total Siloxane Content in Landfill Gas Barbara Marshik MKS Instruments Barbara_Marshik@MKSinst.com Presented at the 2014 LMOP Conference Distribuido

More information

SRI 8610C GC for PCB in Transformer Oil Analysis November 2014

SRI 8610C GC for PCB in Transformer Oil Analysis November 2014 The SRI 8610C Gas Chromatograph ( GC ) is installed on any bench top. When the red lid is raised, you can see the column oven, injector ( on-column type ), detector ( DELCD ) and gas stream dryer. The

More information

AppNote 3/2009. Automation of Solid Phase Extraction Methods using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

AppNote 3/2009. Automation of Solid Phase Extraction Methods using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT AppNote 3/2009 Automation of Solid Phase Extraction Methods using a Robotic X-Y-Z Coordinate Autosampler with Software Control Fred D. Foster, John R. Stuff, Jacqueline A. Whitecavage, Edward A. Pfannkoch

More information

Silicon-Lined Canister Cleaning Practices and Blank VOC Concentrations. Jason S. Herrington, Gary Stidsen, Trent Sprenkle, Steve Kozel

Silicon-Lined Canister Cleaning Practices and Blank VOC Concentrations. Jason S. Herrington, Gary Stidsen, Trent Sprenkle, Steve Kozel Silicon-Lined Canister Cleaning Practices and Blank VOC Concentrations Jason S. Herrington, Gary Stidsen, Trent Sprenkle, Steve Kozel U.S. EPA Method TO-15 A guidance document for a Performance Based Method

More information

Tubing spares and piping accessories. Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box

Tubing spares and piping accessories. Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box Tubing spares and piping accessories 1 Tubing (SS) 2 Teflon tube 3 PU Tube 4 Moduler Piping Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box Tubing

More information

Avensys Avensys FIN EST SLO RUS UAE

Avensys Avensys FIN EST SLO RUS UAE 34 037 Avensys Avensys GB D...1...5 I...5 N...9 GR...13 TR...17 BG...21 RO...25 GB...2 NL...6 FIN...10 CZ...14 SK...18 EST...22 CN...26 F...3 S...7 PL...11 H...15 SLO...19 LV...23 RUS...27 E...4 DK...8

More information

THE RIGHT CONSUMABLES FOR YOUR GC APPLICATIONS. Clarus 590/690 Gas Chromatography Consumables and Supplies Reference Guide

THE RIGHT CONSUMABLES FOR YOUR GC APPLICATIONS. Clarus 590/690 Gas Chromatography Consumables and Supplies Reference Guide THE RIGHT CONSUMABLES FOR YOUR GC APPLICATIONS Clarus 590/690 Gas Chromatography Consumables and Supplies Reference Guide INTRODUCTION AND OVERVIEW For laboratories looking for a single gas chromatograph

More information

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION Visit us at www.lctech.de! What LCTech does supplies innovative products and methods for the preparation and analysis of food,

More information

CLS-1450 Series Spinner Flask Instruction Manual

CLS-1450 Series Spinner Flask Instruction Manual CLS-1450 Series Spinner Flask Instruction Manual Chemglass Life Sciences 3800 North Mill Road Vineland, NJ 08360 USA Phone: 800-843-1794 Email: customer-service@cglifesciences.com Web address: www.cglifesciences.com

More information

intrinsically safe detector for hydrocarbon gases

intrinsically safe detector for hydrocarbon gases portable flame ionisation detector intrinsically safe detector for hydrocarbon gases Intrinsically safe detector for hydrocarbon gases Monitoring gases in confined and potentially explosive situations

More information

CryoFit. Handling of Flow Cell and Capillaries. User Guide. Version 002

CryoFit. Handling of Flow Cell and Capillaries. User Guide. Version 002 CryoFit Handling of Flow Cell and Capillaries User Guide Version 002 Copyright by Bruker BioSpin NMR GmbH. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,

More information

ACQUITY UPLC H-Class Sample Manager - Flow Through Needle Operator s Overview and Maintenance Information

ACQUITY UPLC H-Class Sample Manager - Flow Through Needle Operator s Overview and Maintenance Information ACQUITY UPLC H-Class Sample Manager - Flow Through Needle Operator s Overview and Maintenance Information Revision B Copyright Waters Corporation 2010 All rights reserved Copyright notice 2010 WATERS CORPORATION.

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Germany VM_e.pdf - 18.05.08 Page 1/6 Oil burners fuel unit with solenoid valve

More information

Standard Operating Procedure Gas Chromatograph Mass Spectrometry (GC/MS) - Agilent 7890B GC & 240 Ion Trap MS

Standard Operating Procedure Gas Chromatograph Mass Spectrometry (GC/MS) - Agilent 7890B GC & 240 Ion Trap MS Standard Operating Procedure Gas Chromatograph Mass Spectrometry (GC/MS) - Agilent 7890B GC & 240 Ion Trap MS The Agilent 7890B is a state-of-art gas chromatograph (GC) that provides superior performance

More information

UNIT PANELS 6/25/2014 9:02:04 AM Page 2 of 23

UNIT PANELS 6/25/2014 9:02:04 AM Page 2 of 23 AC126 1 UNIT PANELS 2 REFRIGERANT SYSTEM AIR COOLED 3 REFRIGERANT SYSTEM WATER COOLED 4 WATER SYSTEM - SMALL CUBE 5 WATER SYSTEM - MEDIUM CUBE 6 WATER SYSTEM - LARGE CUBE 7 CONTROL BOX AND P.C. BOARD -

More information

22 The Flame Ionization Detector

22 The Flame Ionization Detector 22 General Information FID pneumatics Special considerations Conditions that prevent the detector from operating Detector shutdown Jets Automatic reignition Lit offset Procedure: Changing the auto-reignite

More information

Essential Equipment for Advanced Laboratory Use. Rotary Evaporator TOKYO RIKAKIKAI CO., LTD.

Essential Equipment for Advanced Laboratory Use. Rotary Evaporator TOKYO RIKAKIKAI CO., LTD. Essential Equipment for Advanced Laboratory Use. Rotary Evaporator TOKYO RIKAKIKAI CO., LTD. N-1001 series Rotary Evaporator Quality design with broad versatility Economic and durable Rotary Evaporator

More information

Sign Planogram: Plumbing Repair Bay Name: Plumbing Repair 4.1. Toilet Repair. 72" from floor to bottom of AV. Replacing a Fill Valve

Sign Planogram: Plumbing Repair Bay Name: Plumbing Repair 4.1. Toilet Repair. 72 from floor to bottom of AV. Replacing a Fill Valve 70054 Toilet Repair 700539 70054 Bay Name: Plumbing Repair 4.1 1 of 1 1 Toilet Repair 72" from floor to bottom of AV 2 3 4 5 6 7 2 Installing a Toilet Ensure that Install a new Place the toilet Tighten

More information

Water Distiller Service Manual

Water Distiller Service Manual Water Distiller Service Manual Water Distiller Service Manual L70478WT 2008 Regal Ware, Inc. Table of Contents RECOMMENDED TOOLS... 2 GENERAL INSPECTION...3 BOILING CHAMBER TROUBLESHOOTING & REPAIRS Description...

More information

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40 1 Safety instructions Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically

More information

Operation Manual. Mobile Dustfree Pressure Air Blasting System HSP-20

Operation Manual. Mobile Dustfree Pressure Air Blasting System HSP-20 Operation Manual Mobile Dustfree Pressure Air Blasting System HSP-20 Clemco International GmbH Carl-Zeiss-Straße 21 Tel.: +49 (0) 8062 90080 83052 Bruckmühl Mail: info@clemco.de Germany Web: www.clemco-international.com

More information

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL LANDING CRAFT UTILITY LCU 1667-1670 NSN 1905-01-168-5764 OPERATOR MAINTENANCE INSTRUCTIONS FOR AUXILIARY

More information

1998 Expedition/Navigator Workshop Manual

1998 Expedition/Navigator Workshop Manual Page 1 of 8 SECTION 412-00: Climate Control System - General Information 1998 Expedition/Navigator Workshop Manual DESCRIPTION AND OPERATION Procedure revision date: 02/11/2000 Climate Control System WARNING:

More information

ISO-9001:2008 DESICCATORS CATALOG. Phone: Fax: Web:

ISO-9001:2008 DESICCATORS CATALOG. Phone: Fax: Web: ISO-900:008 DESICCATORS CATALOG Phone: 8 496 0900 Fax: 8 496 0400 Email: sales@expotechusa.com Web: www.expotechusa.com TABLE OF CONTENTS Vacuum... Cabinets... Desiccants... 8 Vacuum SCIENCEWARE Vacuum,

More information

PWC 7000 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model Copyright 2012 Vertex Water Products

PWC 7000 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model Copyright 2012 Vertex Water Products SERVICE MANUAL for by Vertex Model 7000 Table of Contents 1. Introduction 2. Cooler Set-up 3. Top Cover Removal 4. Remove/Replace Mechanical Float Valve Assembly 5. Removing/Replacing Control Panel and

More information

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1 A AD Oil burners fuel unit deltapumps.com DE116-0709 A-AD_en_0709.pdf - 16.11.09 Page 1/1 Oil burners fuel unit Type A, AD 1- Applications The DELTA aluminium fuel unit type A is an efficient and modern

More information

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS) MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS) FOR PROPER AND SAFE USE OF THIS CHEMCHAMP EQUIPMENT, PLEASE FOLLOW THIS DOCUMENT AND LOCAL AUTHORITY. KEEP THIS DOCUMENT FOR FUTURE REFERENCE.

More information

Food Waste Disposer Instruction Manual

Food Waste Disposer Instruction Manual Food Waste Disposer Instruction Manual See insert for specific information about your new disposer NOTE: IMPORTANT: CAUTION: This Food Waste Disposer has been designed to operate on 110-120 Volt, 60 Hz

More information

INDEX I.- FINAL TEST FOR PRODUCT SAFETY 3 II.- REPLACEMENT PROCEDURES 3 III.- TROUBLE SHOOTING CHART 5 IV.- WIRING DIAGRAM 6 V.- ELECTRICAL RATING 6

INDEX I.- FINAL TEST FOR PRODUCT SAFETY 3 II.- REPLACEMENT PROCEDURES 3 III.- TROUBLE SHOOTING CHART 5 IV.- WIRING DIAGRAM 6 V.- ELECTRICAL RATING 6 INDEX I.- FINAL TEST FOR PRODUCT SAFETY 3 II.- REPLACEMENT PROCEDURES 3 III.- TROUBLE SHOOTING CHART 5 IV.- WIRING DIAGRAM 6 V.- ELECTRICAL RATING 6 VI.- EXTERNAL PARTS FOR UPRIGHT VACUUM CLEANER PARTS

More information

POROUS CONVEYOR LINE PRINTER INDEXING ASSEMBLY POROUS CONVEYOR LINE PRINTER INDEXING ASSEMBLY PARTS LIST INDEX ASSEMBLY BLOCK A

POROUS CONVEYOR LINE PRINTER INDEXING ASSEMBLY POROUS CONVEYOR LINE PRINTER INDEXING ASSEMBLY PARTS LIST INDEX ASSEMBLY BLOCK A STENCILING & MARKING May, 00 SYSTEMS Parts List UNIVERSAL POROUS CONVEYOR LINE PRINTERS CLP-00, CLP-00, CLP-00 & CLP-00 SERIES POROUS CONVEYOR LINE PRINTER INDEXING ASSEMBLY 0 POROUS CONVEYOR LINE PRINTER

More information

DIRECTIONS FOR USE. Keeping you insafehands to avoid needlestick injuries. see for demo video

DIRECTIONS FOR USE. Keeping you insafehands to avoid needlestick injuries. see  for demo video Keeping you insafehands to avoid needlestick injuries Astek Innovations Ltd Astek House I Atlantic Street I Altrincham Cheshire I WA14 5DH I United Kingdom Telephone +44 (0)161 942 3900 I Fax +44 (0)161

More information

Operations Manual. Part Number: For Research Use Only

Operations Manual. Part Number: For Research Use Only Operations Manual Part Number: 470230-598 For Research Use Only Ph: 1-800-962-2660 - Web: www.wardsci.com Thank you for choosing our Bench top sterilizers. Prior to operating this instrument, please read

More information

Agilent 7650A Automatic Liquid Sampler

Agilent 7650A Automatic Liquid Sampler Agilent 7650A Automatic Liquid Sampler Installation, Operation, and Maintenance Agilent Technologies Notices Agilent Technologies, Inc. 2012 No part of this manual may be reproduced in any form or by any

More information

DETERMINATION OF PAH In Particulate Matter PM 10 with SPE/EVAporation

DETERMINATION OF PAH In Particulate Matter PM 10 with SPE/EVAporation DETERMINATION OF PAH In Particulate Matter PM 10 with SPE/EVAporation APPLICATION NOTE www.lctech.de As of: February 2017, Version: 1.2 Determination of PAH In particulate matter PM 10 with SPE/EVAporation

More information

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch Overview continues to be the leader in the chemical feed and disinfection of potable water, wastewater and industrial process applications.

More information

Mitocell: Instructions for Use

Mitocell: Instructions for Use Mitocell: Instructions for Use 1 Introduction The Mitocell (MT200) is designed for the measurement of the respiration rate of either 50 or 100µl sample volumes of mitochondria and cell suspensions. The

More information

ASSEMBLY and INSTALLATION INSTRUCTIONS. Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key

ASSEMBLY and INSTALLATION INSTRUCTIONS. Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key ASSEMBLY and INSTALLATION INSTRUCTIONS Gas Conversion Kit Tube Heaters View these instructions online at www.lbwhite.com Kit Contents: DESCRIPTION QTY. Instructions 1 Burner orifi ce 1 Manifold pipe 1

More information

Cleaning the internal optics surfaces

Cleaning the internal optics surfaces Cleaning the internal optics surfaces The face of the fiber-optic assembly and the lens are directly exposed to sample fluids inside the analyzer s flow cell. Automatic rinse cycles use high-pressure rinse

More information

InfinityLab Quick-Connect Bio-inert Heat Exchanger

InfinityLab Quick-Connect Bio-inert Heat Exchanger InfinityLab Quick-Connect Bio-inert Heat Exchanger Installation in an Agilent 1260 Infinity II MCT This technical note describes the installation of Bio-inert Heat Exchangers to an Agilent 1260 Infinity

More information

Virtual Industries, Inc.

Virtual Industries, Inc. VACUUM Handling Tools & Accessories Virtual Industries, Inc. SELF CONTAINED MANUALLY OPERATED HANDLING TOOLS 1 PEN-VAC ESD-SAFE VACUUM HANDLING TOOLS STATIC DISSIPATIVE NON-MARKING BUNA-N CUPS TEMPERATURE

More information

PARTS GLOSSARY Basic Insufflation Pro Package

PARTS GLOSSARY Basic Insufflation Pro Package PARTS GLOSSARY Basic Insufflation Pro Package www.promolife.com 888-742-3404 www.promolife.com/support/ www.promolife.com/videos/ EQUIPMENT, TUBING AND ACCESSORIES E O3Elite Single Ozone Generator Tubing

More information

Climate Control System

Climate Control System Page 1 of 13 SECTION 412-00: Climate Control System General Information DESCRIPTION AND OPERATION 1998 Mark VIII Workshop Manual Climate Control System Cautions and Warnings WARNING: To avoid accidental

More information