1 Based On The MV7 Master Mixing Valves APPLICATION: The Acorn SFMMV Series Multi-Valve Supply Fixtures can be accurately referred to as a High/Low Multi-Valve fixture, compliant with the temperature control requirements of ASSE 07 at flow rates well below the ASSE standard tested flow rate. The SFMMV Series Multi-Valve Supply Fixture are ideal for applications without recirculating pumps where the minimum flow for accurate control can be met by the actual demand of but a few fixtures. They are also ideal for recirculating systems where demand can vary from the pump draw alone (no user demand) up to a very high user usage. From small to large commercial applications, the SFMMV series is offered in 0 models/sizes to allow you to select the valve with the capacity and performance capable of delivering safely controlled tempered hot water to all your fixtures, at all times. FEATURES: l G Lead-Free soldered assembly featuring a DZR brass body mixing valve containing corrosion-resistant internal components. l Integral cartridge style checks with screens to prevent backflow and to filter debris from entering the valve. l Temperature adjustment is made using an Allen wrench. A locknut on the bonnet prevents unauthorized or accidental temperature adjustment. l Commercial quality paraffin actuator provides repeatable, reliable performance. l Includes lockable full port brass ball valves on inlet and outlet connections. l Temperature/Pressure gauges on inlets and outlet. l IAPMO certified per ASSE 07 and CSA B.. l Factory assembled and pneumatically tested to 80 PSI ( kpa). l The MV7 is capable of exceeding the temperature control accuracy requirements of ASSE 07 at Zero GPM actual user demand. The system must include a continuously operating recirculation pump capable of meeting the minimum flow rate shown on the enclosed chart ( to GPM based on the model) with a correctly adjusted balancing valve. l Optional Controlled Valve Staging eliminates the need for a PRV when lower minimum flows are required. l Upgradable to Acorn BASyC. Revised: 08/0/8 SFMMV- (Shown) SPECIFICATIONS: Patent Pending * Under Normal Operating Conditions. G The wetted surface of these valves contacted by consumable water contains less than 0.% of lead GUIDE SPECIFICATION: by weight in conformance with national lead free-law. SFMMV Series Multi-Valve Supply Fixtures shall be factory assembled and feature MV7 Series Mixing Valves which contain an advanced paraffin sensor with a temperature range of 00 F to 0 F (7.8 C to 7 C) and factory set at 0 F (8 C) with a locknut to prevent unauthorized temperature changes. Fixture shall also include copper piping, lockable ball valves and a temperature/pressure gauges standard. Valve bodies material shall be lead-free brass with corrosion-resistant internal components. Fixture shall include temperature/ pressure gauges on inlets and outlet. Multi-Valve Supply Fixture shall be Acorn model SFMMV-. Please visit or most current Page of 7 ASSE 07 CSA B. Valve Specifications: Maximum Operating Pressure:... PSI (8 kpa) Maximum Hot Water Supply Temp: F (8 C) Outlet Temp. Range: F-0 F (8 C-7 C) Minimum Hot Water Supply*... F ( C) Above Set Point Flow Rate at PSI (0 kpa) differential: SFMMV-:... GPM ( LPM) SFMMV-:... 9 GPM (78 LPM) SFMMV-: GPM (0 LPM) SFMMV-: GPM (8 LPM) SFMMV-:... 0 GPM (908 LPM) SFMMV-:... GPM (9 LPM) SFMMV-: GPM ( LPM) SFMMV-:... 7 GPM (0 LPM) SFMMV-:... 0 GPM (70 LPM) SFMMV-:... 7 GPM ( LPM) Certified Minimum Flow: SFMMV-:... GPM ( LPM) SFMMV-:... GPM ( LPM) SFMMV-:... GPM (9 LPM) SFMMV-:... GPM ( LPM) SFMMV-:... GPM (9 LPM) SFMMV-:... GPM ( LPM) SFMMV-:... GPM ( LPM) SFMMV-:... 7 GPM (7 LPM) SFMMV-:... 8 GPM (0 LPM) SFMMV-:... GPM ( LPM) Federal Public Law -80 (No Lead) P.O. BOX 7 97, U.S.A. -- Fax -9-00
2 VALVE SELECTION: o SFMMV- -/ Inlets & Outlet, GPM ( LPM) o SFMMV- -/ Inlets & Outlet, 9 GPM (78 LPM) o SFMMV- Inlets & -/ Outlet, 70 GPM (0 LPM) o SFMMV- -/ Inlets & Outlet, 80 GPM (8 LPM) q SFMMV- -/ Inlets & -/ Outlet, 0 GPM (908 LPM) o SFMMV- Inlets & Outlet, GPM (9 LPM) o SFMMV- -/ Inlets & Outlet, 00 GPM ( LPM) o SFMMV- Inlets & Outlet, 7 GPM (0 LPM) o SFMMV- Inlets & Outlet, 0 GPM (70 LPM) o SFMMV- Inlets & Outlet, 7 GPM ( LPM) VALVE OPTIONS: o o -CWB o -HWB o -TBV "H" Controlled Valve Staging Assembly Cold Water Bypass (Includes a Reducer and Ball Valve) Specify Pipe Size o / r / o o -/ o -/ o Hot Water Bypass (Includes a Reducer and Ball Valve) Specify Pipe Size o / r / o o -/ o -/ o Thermostatic Balancing Valve Specify Pipe Size o / r / o o -/ o -/ o "E" "I" TEMPERATURE/PRESSURE GAUGES SENSOR PORTS FOR UPGRADING TO ACORN BASyC SYSTEM CVS VALVE LOW FLOW VALVE "D" -CWB COLD WATER BYPASS BALL VALVE -HWB HOT WATER BYPASS BALL VALVE "B" "A" #SFMMV--CWB--/ -HWB--/ SHOWN FOR REFERENCE "J" SEE PAGES AND FOR FLOW CHART AND PAGE FOR DIMENSIONAL CHART # SFMMV Series Revised: 08/0/8 WARNING: Cancer and Reproductive Harm - Acorn Controls warrants that its products are free from defects in material or workmanship under normal use and service for a period of one year from date of shipment. Acorn s liability under this warranty shall be discharged solely by replacement or repair of defective material, provided Acorn is notified in writing within one year from date of shipment, F.O.B. City of Industry, California. Page of 7 SELECTION SUMMARY & APPROVAL FOR MANUFACTURING Model Number & Options Quantity Company Contact Title Signature (Approval for Manufacturing) Date or --
3 Based On The MV7 Master Mixing Valves FLOW CHART: PRESSURE DROP PSID (kpa) CV MINIMUM FLOW () 0 (9) (0) 0 (8) 0 (07) (0) 0 () SFMMV- 0. () (70) () 78 (9) 90 () 0 () () (9) SFMMV- 9. () () 9 (8) (8) 0 (9) 9 (0) 9 (78) (8) SFMMV- 0. (9) 90 () 7 (8) (9) 80 (8) 0 (8) 70 (0) (8) SFMMV-.8 () 0 (7) 8 () 0 (9) 0 () 7 () 80 (8) 08 (787) SFMMV-.8 (9) 80 (0) (8) 0 (0) 0 (0) 9 (78) 0 (908) 77 (09) SFMMV-.9 () 0 (97) 8 (0) 8 (89) 0 (79) 7 (97) (9) (78) SFMMV-.8 () 00 (79) () 7 () 00 (77) (97) 00 () (0) SFMMV-.9 7 (7) (7) 77 (70) 7 (8) 0 (9) 0 (8) 7 (0) (9) SFMMV (0) 0 (8) (80) 0 (98) 00 (7) 7 (89) 0 (70) 0 (98) SFMMV- 00. () (8) 8 (0) 90 (7) 0 (70) (7) 7 () 779 (99) NOTE: ASSE 07 performance based on actual demand or recirculation pump flow rate or a combination of both. See FEATURES regarding control performance at ZERO GPM user demand. Please visit or most current Revised: 08/0/8 Page of 7 ASSE 07 CSA B. P.O. BOX 7 97, U.S.A. -- Fax -9-00
4 Based On The MV7 Master Mixing Valves FLOW CHART: PRESSURE DROP PSID (kpa) CV MINIMUM FLOW () 0 (9) (0) 0 (8) 0 (07) (0) 0 () SFMMV- 9.9 (.8) (70) (8) 77 (9) 89 (7) 09 () (07) (8) SFMMV- 8.7 (.8) () 9 () (0) 8 (8) 7 (9) 9 (7) (80) SFMMV- 9.7 (.8) 89 (7) (77) (8) 78 (7) 7 (8) (007) 08 () SFMMV-. (7.) 0 (7) 8 (8) 0 (90) 9 (0) () 79 (78) 0 (780) SFMMV-. (7.) 79 (99) () 7 (8) 8 (98) 9 (7) 8 (90) 7 (07) SFMMV-. (7.) 0 (9) 7 () 80 (8) 08 (787) (9) (77) 9 (9) SFMMV-. (.) 99 (7) 0 (9) 7 () 98 (70) (90) 98 (8) (0) SFMMV-. (.) (9) 7 () (80) 8 (99) 0 (7) 7 (0) 9 () SFMMV-. (.) 9 () 0 (79) 8 (977) 98 (8) (78) (88) (99) SFMMV- 00. (.) (88) 7 (00) 88 (9) 8 (9) 8 (07) 7 (0) 77 (9) NOTE: ASSE 07 performance based on actual demand or recirculation pump flow rate or a combination of both. See FEATURES regarding control performance at ZERO GPM user demand. Please visit or most current Revised: 08/0/8 Page of 7 ASSE 07 CSA B. P.O. BOX 7 97, U.S.A. -- Fax -9-00
5 Based On The MV7 Master Mixing Valves TECHNICAL DIMENSIONAL CHART: INLET OUTLET "A" "B" "D" "E" "H" "I" "J" SFMMV- -/ " -/ (9) -/" (97) 0" () 7" -/" (90) () () (9) (0) SFMMV- -/" " -/" -/" (97) 8-/ () 7" (90) -/" () -/ () -/8" (8) (0) SFMMV- " -/" -/ -/" (97) 9-/8" () -/" -/" () 7-/ () -/" (8) -/ SFMMV- -/ " -/ (9) 0-/ (0) 0" () 7" (90) 9-/ () () (9) (0) SFMMV- -/" -/" -/" 0-/ (0) 7-/ (97) 7" (90) 9-/ () -/ (00) 0-/" (7) (0) SFMMV- " -/ 0-/ (09) 8-7/8" () -/" 9-/" (7) 7-/" () " (0) -/ SFMMV- -/" " -/" 0-/ (0) 9-/8" (8) 7" (90) 9-/ () -/ () " (79) (0) SFMMV- " -/ -/" 0" () -/" 0-/" (8) (8) -/" () -/ SFMMV- " -/ -/" 0-/8" (7) -/" 0-/" (8) 9-/ (89) -/ (7) -/ SFMMV- -/ 0" () 0-/8" () -/" (7) 0-/" () (8) -7/8" () Please visit or most current Revised: 08/0/8 Page of 7 ASSE 07 CSA B. P.O. BOX 7 97, U.S.A. -- Fax -9-00
6 Based On The MV7 Master Mixing Valves -TBV TECHNICAL DRAWING: "H" 7 "E" "I" 8 "D" 0 9 "M" "L" "B" "A" "K" "J" TEMPERATURE/PRESSURE GAUGES TEMPERATURE AND PRESSURE SENSOR PORTS FOR UPGRADING TO ACORN BASyC SYSTEM CVS VALVE LOW FLOW VALVE / -CWB COLD WATER BYPASS (SHOWN) -CWB COLD WATER BYPASS BALL VALVE 7 / -HWB HOT WATER BYPASS (SHOWN) 8 -HWB HOT WATER BYPASS BALL VALVE 9 -TBV THERMOSTATIC BALANCING VALVE 0 RETURN TEMPERATURE GAUGE RETURN TEMPERATURE SENSOR PORT /" RETURN SFMMV--CWB-/ -HWB-/ -TBV SHOWN FOR REFERENCE Please visit or most current Revised: 08/0/8 Page of 7 ASSE 07 CSA B. P.O. BOX 7 97, U.S.A. -- Fax -9-00
7 Based On The MV7 Master Mixing Valves -TBV TECHNICAL DIMENSIONAL CHART: INLET OUTLET "A" "B" "D" "E" "H" "I" "J" "K" "L" "M" SFMMV- -/ " -/ (9) -/" (8) 0" () 8-7/8" -/" () (0) () (9) (0) (9) () SFMMV- -/" " -/" 7-/" (0) 8-/ () 8-7/8" () -/" () -/ () -/8" (8) (0) 9-/ () 0-7/8" SFMMV- " -/" -/ 8" (9) 9-/8" () -/ (78) 7" (8) 7-/ () -/" (8) -/ 9-/ () " (79) SFMMV- -/ " -/ (9) 0-/" (8) 0" () 8-7/8" () 9-/" () () (9) (0) (9) () SFMMV- -/" -/" -/" 0-/" (8) 7-/ (97) 8-7/8" () 9-/" () -/ (00) 0-/" (7) (0) 9-/ () () SFMMV- " -/ -/ (08) 8-7/8" () -/ (78) 0-/" (7) 7-/" () " (0) -/ 9-/ () " (79) SFMMV- -/" " -/" -/ (08) 9-/8" (8) 8-7/8" () 9-/" () -/ () " (79) (0) 9-/ () () SFMMV- " -/ -/ (08) 0" () -/ (78) 0-/" (7) (8) -/" () -/ 9-/ () " (79) SFMMV- " -/ -/ (08) 0-/8" (7) -/ (78) 0-/" (7) 9-/ (89) -/ (7) -/ 9-/ () " (79) Please visit or most current Revised: 08/0/8 Page 7 of 7 ASSE 07 CSA B. P.O. BOX 7 97, U.S.A. -- Fax -9-00
Model SFMV Series. Lead-Free Supply Fixtures Based On The MV17 Master Mixing Valves
Model SFMV Series Lead-Free Supply Fixtures Based On The MV17 Master Mixing Valves APPLICATION: The Acorn SFMV Series Supply Fixtures can be accurately referred to as a High/Low valve fixture, compliant
More informationInstallation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves
Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Hot Water Tempered Water Outlet Cold Water Tempered Water Outlet Redundant Thermostatic Mixing Valve Hot Water
More informationINSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE
Bulletin 82 August, 208 INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES, -LF,, -LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!!!
More informationNote: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF
Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer 1/2" OD Copper Tube Inlets Hot Water Inlet Cold Water Inlet G3600LF Installation 1. Install valve in
More informationDigiTemp. Digital Water Tempering System. PVI.com
DigiTemp Digital Water Tempering System PVI.com DigiTemp Digital Water Tempering System DigiTemp is a domestic hot water main mixing station for commercial and institutional facilities that intelligently
More informationInstallation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves
Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet Cold Water Thermometer Hot Water Inline Check Redundant Thermostatic Mixing Valve Angle Checkstops
More informationNote: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.
Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet Angle Checkstop Angle Checkstop Hot Water Inlet G3700LF Cold Water Inlet Installation 1.
More information5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341
NA31 www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 1 Caleffi Installation, commissioning and service instructions Function 531 Series ASSE 17 model 531 series high flow thermostatic
More informationINSTALLATION ADJUSTMENT SERVICE
Bulletin XL-670 July 201 INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE MODEL XL-670-LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! ECO-MIX
More informationModel 9201EFE Tempered Water Blending System
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 9201EFE Tempered Water
More informationModel TWBS.SHE Tempered Water Blending System
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model TWBS.SHE Tempered Water
More informationModel 9201EW Tempered Water Blending System
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 9201EW Tempered Water Blending
More informationINSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82
Bulletin XL-38 March 00 INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-3, XL-8 IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!!
More informationMEGATRON MODEL 2, 3, 4, and 5
MEGATRON MODEL 2, 3, 4, and 5 BULLETIN M-1020A 2/02 INSTALLATION ADJUSTMENT SERVICE COMPLETE WATER TEMPERATURE CONTROL STATION DOMESTIC OUTLET TEST/SETUP CONNETION RETURN LINE FROM BUILDING RETURN LINE
More informationAutomatic Temperature Controller (ATC)
NEW FROM APOLLO...THE FIRST MULTIPLE-FIXTURE HI-LO MIXING VALVE THAT MEETS ASSE 1017 AND THE NEW ASSE 1069 STANDARD Only Apollo offers fast delivery on the first water temperature mixing assembly to meet
More information5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.
NA3. www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 5 Caleffi Installation, commissioning and service instructions Function 53 Series ASSE 7 model 53 series high fl ow thermostatic
More informationHYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F
34-200 SERIES HYDRONIC TEMPERING VALVES The Apollo Model TV (34-200 Series) thermostatic mixing valve provides non-asse extension of water heater capacity and hot water temperature control in hydronic
More informationINSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE
Bulletin XL-150 February 2015 INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-150, XL-150-LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering
More informationProduct Specification
ES-P-450-e420 HydroPanel II Shower System With HydroGuard e420 Combination Valve Product Specification Features n e420 temperature/pressure combination valve quickly compensates for both pressure and temperature
More informationINSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982
Bulletin LV-98 March 010 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES & LV-98 IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! ASSE 1017
More informationINSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE
Bulletin GLV-0 September 01 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE LV-0, LV-0-LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! INSTALLATION
More informationINSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE
Bulletin GLV- January 014 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE LV-, LV--LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! INSTALLATION
More informationTA-300, TA-300-LF, TA-350, TA-350-LF
Bulletin G-5 INSTALLATION SETUP AND OPERATING INSTRUCTIONS EMERGENCY MIXING VALVE SYSTEM TA-300, TA-300-LF, TA-350, TA-350-LF IMPORTANT! Provide valve serial number (located on valve body) when ordering
More informationOUTLET HOT INLET COLD INLET INSTALLATION
Bulletin G-29 December 2007 INSTALLATION ADJUSTMENT SERVICE TYPE TM-28 IMPORTANT! Provide valve serial number (stamped on cover of valve) when ordering parts!! Valve manufactured after July 2007 starting
More informationHL45, HL80 Thermostatic High-Low Valves
Lead-Free Brass Design Reliable Liquid-Filled Thermostat with 10 year warranty Integral Strainer Checkstops on Inlets Adjustable Set Point within Temperature Range Accurate Temperature Control to within
More informationWATER CONTROL VALVES
CASH ACME CATALOG WATER CONTROL VALVES THAT STAND THE TEST OF TIME In 1893, A.W. Cash designed a valve for U.S. Navy submarines. With the bottom of the sea as his testing ground, the valve became celebrated
More informationINSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE
. Bulletin XL-200 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES XL-200, XL-200-LF, XL-200-SW, XL-200-SW-LF IMPORTANT! Provide valve serial number, (located on valve cover) when
More informationSECTION DOMESTIC WATER PIPING SPECIALTIES
SECTION 22 11 19 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationINSTALLATION ADJUSTMENT SERVICE
ASSE 1017 INSTALLATION ADJUSTMENT SERVICE TYPE TM-26, TM-26-LF BULLETIN G-26 January 2014 IMPORTANT! Provide valve serial number (stamped on cover of valve) when ordering parts!! Valve manufactured after
More informationINSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE
Bulletin GLV-99 July, 01 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE LV-981A, LV-981A-LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! INSTALLATION
More informationINSTALLATION & TESTING MANUAL
INSTALLATION & TESTING MANUAL ***CAUTION: Do not lift by yellow enclosure. Reference installation instructions for proper lifting and moving techniques. IMPROPER INSTALLATION MAY RESULT IN RISK OF SCALDING
More informationMEGATRON MODEL 2NB-LF, 3NB-LF, 4NB-LF, 5NB-LF NEXT GENERATION MANIFOLD SYSTEMS TM-520B-LF, 820B-LF, 920B-LF, 1520B-LF
6 1-1 3 8 5 6 1 6 2 1 4 1 8 6 8 kg/cm2 11 psi 1 16 1 1 1 6 1 ASSE 117 VAL VE -1 CO. 3 6 8 5 1 THEMOSTATIC T YPE TM AN STON 1 1.I. U.S.A. 6 1-1 6 3 8 1 5 1 1 6 1-1 6 3 8 5 1 1 1 H C Bulletin M-115Z August,
More informationINSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)
ASSE 1017 INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA) BULLETIN P-15A January, 2014 IMPORTANT! Provide valve serial number when ordering
More informationSubmittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION
! APPROXIMATE DIMENSIONS A = 3-3 B = 3-10-1/2 C = 4 D = 9-1/2 *Image not to scale* WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer.
More informationINSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE
Bulletin GLV-101 Old Rev. LV-101 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-983, LV-983-LF & LV-984, LV-984 -LF IMPORTANT! Provide valve serial number, (located on valve
More informationTankless Electric Water Heater Available 3-27 kw in Single Phase Voltages
Point-of-Use Tankless Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages Features Heavy Duty Construction Reliability Constructed with high grade materials to ensure long operating
More informationINSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE
Bulletin GLV-98 Old Rev. LV-98 February 1 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES, LV981-LF &, -LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering
More informationSubmittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified
! APPROXIMATE DIMENSIONS A = 3-11 B = 3-9 C = 4-1/2 D = 1-1 *Image not to scale* WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer.
More informationInstallation S
Installation S59-2025 Thermostatic Mixing Valve (TMV25) with Optional Cabinet S59-2025RE (with Recess-Mounted Enamel Cabinet) S59-2025RS (with Recess-Mounted Stainless Steel Cabinet) S59-2025SE (with Surface-Mounted
More informationINSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550
C BULLETIN G-6A January 2012 INSTALLATION SETUP AND OPERATING INSTRUCTIONS WATER SYSTEM TM-500, TM-550 IMPORTANT! Provide valve serial number (located on valve body) when ordering parts!! Starting with
More informationRada 25R Installation and Maintenance
ALIB-25R Rada 25R Installation and Maintenance Rada Solutions for Central Recirculation System Control This Rada 25R Valve has been supplied for this application based upon information provided to Armstrong-Lynnwood
More informationTECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:
ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 91744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS ELECTRIC ALARM WITH LIGHT AND HORN Models S0000-AL1
More informationINSTANT-FLOW C-MICRO WATER HEATER
WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS (LOW ACTIVATION MODELS) TABLE OF CONTENTS Technical Information..................................... 2 Dimensional Data........................................
More informationSOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual
SOLARHOT SuperVox Installation/ Owner s Manual Description / Applications System Overview The SOLARHOT SuperVox solar thermal glycol system. The SuperVox allows for easy installation of large solar water
More informationASSE 1017 Point of Source Commercial. Mixing Valves. Mixing Valves. MVA (34A) Series/MVAH Hydronic Series
ASSE 1017 Point of Source Commercial Mixing MVA (34A) Series/MVAH Hydronic Series The Apollo MVA thermostatic master mixing valves are designed for ASSE 1017 point of source applications. They provide
More informationINSTALLATION & TESTING MANUAL
LP LOW PRESSURE UNIT ISO9001 CERTIFIED INSTALLATION & TESTING MANUAL ***CAUTION: Do not lift by yellow enclosure. Reference installation instructions for proper lifting and moving techniques. INSTALLATION
More informationInstallation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Product Preservers Anti-Scale System Chemical-Free, Salt-Free Scale Prevention Introduction The Product Preservers Anti-Scale System will condition the tap
More informationINSTANT-FLOW C-MICRO WATER HEATER
WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS (LOW ACTIVATION MODELS) TABLE OF CONTENTS Technical Information..................................... 2 Dimensional Data........................................
More informationTankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages
Model HX/TX Tankless Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages Features Heavy Duty Construction Constructed with high grade materials to ensure long operating
More informationThermostatic mixing valves with interchangeable cartridges
www.caleffi.com R37. Thermostatic mixing valves with interchangeable cartridges Installation, commissioning and servicing instructions 3 Series Function The thermostatic mixing valve is used in systems
More informationINSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS AquaArctic Remote Water Chiller A9100080 -A TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 1.800.591.9360 Technical Assistance Fax: 1.626.855.4894
More informationCAPABILITIES BROCHURE
CAPABILITIES BROCHURE Casey Hayes VP/GM, Acorn Engineering Systems TEL: 775-224-1151 chayes@acorneng.com Introduction... 2 AES MODEL SELECTOR... 3 Standard Tempering Specifications: Indoor and Outdoor...4-5
More informationHome. One Source For All Your Potable Water Needs
Home One Source For All Your Potable Water Needs AMX300 Thermostatic Mixing Valve Kit Installation that s literally almost no sweat. Kit includes mixing valve, cold water tee, flexible 8" or 11" metal
More informationINSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed
ASSE 1017 INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed *Valve is CUPC listed IMPORTANT! Provide valve serial number
More informationHoneywell Water Solutions. Thermostatic Mixing Valves
Honeywell Water Solutions Thermostatic Mixing Valves AMX300 Thermostatic Mixing Valve Kit Key Features and Benefits Kit includes mixing valve, cold water tee, flexible 8" or 11" metal connectors, and thermostrip
More information2016 CASH ACME CATALOG
2016 CASH ACME CATALOG WATER CONTROL VALVES THAT STAND THE TEST OF TIME In 1893, A.W. Cash designed a valve for U.S. Navy submarines. With the bottom of the sea as his testing ground, the valve became
More information281 Series. ThermoBloc boiler protection recirculation and distribution unit. Installation, commissioning and servicing instructions
www.caleffi.com NA1094.01 ThermoBloc boiler protection recirculation and distribution unit Copyright 013 Caleffi Installation, commissioning and servicing instructions 81 Series Function The ThermoBloc
More informationHigh Capacity Instantaneous Steam Fired Water Heater
MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and
More informationINSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A
C ASSE 1017 BULLETIN G-6B March 2009 INSTALLATION SETUP AND OPERATING INSTRUCTIONS WATER SYSTEM * TM-500A, TM-550A IMPORTANT! Provide valve serial number (located on valve body) when ordering parts!! *ASSE
More informationNachi Series TM Z6957-XL
Nachi Series TM Wall-Mounted Sensor-Operated Lavatory Faucets for Battery or Plug-In Installations. Installation, Operation, Maintenance, and Parts Manual Z6957-XL Wall-Mounted Sensor-Operated Battery-Powered
More informationTMV45 & TMV80 Standard Thermostatic Mixing Valves
Reliable liquid-filled thermostat Integral strainer checkstops on inlets Adjustable set point within temperature range Accurate temperature control Positive shutoff of hot supply when cold supply is lost
More informationCircuit SolverTM THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS.
www.circuitsolver.com The Problem 1 Water flows to the path of least resistance. The Solution Install a Circuit Solver on each hot water supply branch line immediately downstream of the last runout to
More information521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions
MixCal adjustable three-way thermostatic mixing valve 37. www.caleffi.com Copyright 15 Caleffi 51 Series Installation, commissioning and service instructions Function The Caleffi MixCal three-way thermostatic
More informationInstallation S
Installation S59-3045 Thermostatic High-Low Mixing Valve (HL45) with Optional Cabinet S59-3045 (Valve Only) S59-3045RE (with Recess-Mounted Enamel Cabinet) S59-3045RS (with Recess-Mounted Stainless Steel
More informationInstallation S
Installation S59-3080 Thermostatic High-Low Mixing Valve (HL80) with Optional Cabinet S59-3080RE (with Recess-Mounted Enamel Cabinet) S59-3080RS (with Recess-Mounted Stainless Steel Cabinet) S59-3080SE
More informationInstallation S
Installation S59-3200 Thermostatic Mixing Valve (HL200) with Optional Cabinet S59-3200RE (with Recess-Mounted Enamel Cabinet) S59-3200RS (with Recess-Mounted Stainless Steel Cabinet) S59-3200SE (with Surface-Mounted
More informationRada 320R Installation and Maintenance
ALIB-320R-B Rada 320R Installation and Maintenance Water Temperature Controls Recirculation Systems Thermostatic This Rada 320R Valve has been supplied for this application based upon information provided
More informationAM Series Proportional Thermostatic Mixing Valve
AM-1 1070 Series Proportional Thermostatic Mixing Valve PATENTED, WIT DUAL ASSE 1070 AND 1017 ERTIFIATION, IAPMO AND SA LISTING IN ONE VALVE PRODUT DATA PRODUT INFORMATION SPEIFIATIONS Media Temperature
More informationProcess Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW
MODEL V Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW Features Industrial Grade Construction Stainless steel pressure vessel provides maximum service
More informationModel TWBS.EW.H Tempered Water Blending System
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model TWBS.EW.H Tempered Water
More informationOwner s Manual Refrigerated Compressed Air Dryers Model F-100
Owner s Manual Refrigerated Compressed Air Dryers Model F-100 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing
More informationModel NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 9400 No. 2080243(7) NOTE
More informationMODEL TA. TA-SB 117.5mm mm HOT INLET. TA mm mm mm mm
WATER MIXER WATER MIXER TRERMOSTATIC WATER MIXER TRERMOSTATIC C TRERMOS TA TIC WA TER MIXER MODEL TA Bulletin P-7A-4 May 2011 (NEW STYLE) THERMOSTATIC WATER MIXING VALVES INSTALLATION SETUP AND OPERATING
More informationThermostatic Mixing Valves
Thermostatic Mixing Valves Reliable, ASSE-listed valves from a recognized leader in flow-control products Watts.com The Trusted Choice for Thermostatic Mixing Valves Watts provides a complete thermostatic
More informationINSTALLATION ADJUSTMENT SERVICE NEXT-GENERATION MANIFOLD SYSTEMS TM-520B-LF, TM-820B-LF, TM-920B-LF, TM-1520B-LF
2 6 4 1 O. RANSTON RI USA TYP TM U S. Pat en ts 2. 97, 3, 6 1,1 95 3.15 2,76 8 2 3 R 4 5-1 6 F 14 1 12 Bulletin G-12 August, 218 INSTALLATION ADJUSTMENT SERVIE NEXT-GENERATION MANIFOLD SYSTEMS TM-52B-,
More informationModel T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING!
Application Legend thermostatic mixing valves are designed for applications requiring temperature control, scald prevention and reduction of thermal shock in domestic potable water distribution (Model
More informationRada 425R Installation and Maintenance
ALIB-425R-B Rada 425R Installation and Maintenance Water Temperature Controls Recirculation Systems Thermostatic This Rada 425R Valve has been supplied for this application based upon information provided
More informationCALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA
Thermostatic mixing valves with replaceable cartridge for centralized systems 3, 3 series CCREDITED ISO 9 FM ISO 9 No. 3 /3 N Replaces / N Function The thermostatic mixing valve is used in systems producing
More informationEMERGENCY DRENCH SHOWER
EMERGENCY DRENCH SHOWER PRODUCT CODE S2200 Date: March 2014 Horizontally Mounted Emergency Shower, Stainless Steel Shower Head Model S2200 is a horizontally mounted emergency shower with a stainless steel
More informationADMS. AERCO Digital Mixing Station. AERCO.com
ADMS AERCO Digital Mixing Station AERCO.com AERCO Digital Mixing Station The AERCO Digital Mixing Station (ADMS ) is a smart water tempering system that allows temperature controlled distribution of potable
More informationInstallation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014
Installation S59-3400 HL2X2 High Capacity Manifold System Table of Contents Supplies Required... 3 Rough-Ins... 3 Connect Supply Lines and Install Thermometer... 4 Adjust Temperature and Test Unit... 5
More informationFFH Series. Steam Fired Instantaneous Feed Forward Water Heaters
FFH Series Steam Fired Instantaneous Feed Forward Water Heaters CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA 15024 Phone: (724) 274-5430 FAX: (724) 274-5448 www.cemline.com Operation of Cemline
More informationInstallation S
Installation S59-3080 Thermostatic Mixing Valve with Optional Cabinet S59-3080RE (with Recess-Mounted Enamel Cabinet) S59-3080RS (with Recess-Mounted Stainless Steel Cabinet) S59-3080SE (with Surface-
More informationFFP S700 SERIES. Pull-Out Spray Faucet. Installation guide
FFP S700 SERIES Pull-Out Spray Faucet Installation guide G 1782 G 1748.XX G 29016 G 1156 G R0239.XX G 13396.XX G R0637 G R1664 G 1636 G 1463 TECHNICAL DATA Minimum working pressure 0,5 bar Maximum working
More informationCALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA
Thermostatic mixing valves, low-lead, high-flow 5 series CCREDITED ISO 9 FM 5 ISO 9 No. CLEFFI 5/ N Replaces 5/5 N Function The thermostatic mixing valve is used in systems producing domestic hot water
More informationSS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER
SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER Features: Ability to pre-select water temperature thus conserving water Paraffin wax element maintains
More informationINSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM PRV, 8015, 12520, 15020)
OT BULLETIN P-15 June, 2006 INSTALLATION ADJUSTMENT SERVIE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM-186-5015-PRV, 8015, 12520, 15020) IMPORTANT! Provide valve serial
More informationINSTALLATION INSTRUCTIONS
Harwil Model Q-16 fluid flow switch is intended for use in flow lines with fluids not harmful to brass, stainless steel, and EPDM. The switch is used to signal, start, or stop electrically operated equipment
More informationZero Waste Retrofit Kit Instruction
Zero Waste Retrofit Kit Instruction B CHECK C FLOW RESTRICR FOR 25-35 GPD (500ML - GREEN INSERT) O WIRE HARNESS A BLACK TUBE D FLOW RESTRICR FOR 50 GPD (700ML- PURPLE INSERT) P GREEN TUBE F F J I J E SELENOID
More informationENGINEERING SPECIFICATIONS
ENGINEERING SPECIFICATIONS RH-24-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 24 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.
More informationDESIGNED BY FIRE FIGHTERS FOR FIRE FIGHTERS.
DESIGNED BY FIRE FIGHTERS FOR FIRE FIGHTERS. DESIGNED BY FIRE FIGHTERS / FOR FIRE FIGHTERS At American Fire & Safety Equipment we focus on providing the most hardened, reliable, products, which can be
More informationENGINEERING SPECIFICATIONS
ENGINEERING SPECIFICATIONS RH-12-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 12 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.
More informationOwner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350
Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others
More informationSemi-Instantaneous Indirect Fired Water Heater
MODEL BWX Semi-Instantaneous Indirect Fired Water Heater Use Boiler Water Or HTHW To Heat Domestic Water Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone
More informationCALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA
TankMixer water heater tank mixing valve 520 series CLEFFI 01267/17 N CCREDITED ISO 9001 FM 21654 ISO 9001 No. 000 Function The Caleffi TankMixer 520_X series kit combines a three-way thermostatic mixing
More informationOwner s Manual Refrigerated Compressed Air Dryer Model F-50
Owner s Manual Refrigerated Compressed Air Dryer Model F-50 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all
More informationBRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9
BRADLEY THERMOSTATIC MIXING VALVES Bradley Corporation, a leader in the manufacture of fixtures and plumbing products, produces four lines of thermostatic mixing valves (TMVs). Bradley Navigator High-Low
More informationTECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:
ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 91744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS ELECTRIC ALARM WITH LIGHT AND HORN Model: S0000-AL2-C1D1-DB1
More informationProPet Washer. I-1020 Page 1 of 6 Rev. D /15/11
ProPet Washer Overview The ProPet Washer incorporates up to 4 products with a rinse option to safely bathe animals. The different products are easily selected by the turn of a knob. Different dilution
More informationThermostatic mixing valves with replaceable cartridge for centralized systems
Thermostatic mixing valves with replaceable cartridge for centralized systems series REGISTERED BS EN ISO 9: Cert. n FM UNI EN ISO 9: Cert. n / N Replaces /9 N Function The thermostatic mixing valve is
More information