Vicot Air Conditioning Co., Ltd. CONTENT
|
|
- Posy Casey
- 5 years ago
- Views:
Transcription
1
2 CONTENT I. Introduction 2 II. Absorption Principle 3 III. GAX Absorption Cycle 3 IV. Major Component Description and Function 4 V. Features 4 VI. Performance curve 5 VII. Nomenclature 5 VIII. Technical Data 6 IX. Dimensions 7 X. Application 8 XI. Typical Chilled Water Piping 9 AIR COOLED GAS FIRED ABSORPTION CHILLER
3 I. Introduction The Vicot gas fired water chiller is a high efficiency gas fired water chiller for residential and light commercial air conditioning duty. The chiller is designed to be installed outdoors and connected with a chilled water coil located in the indoor air handling system for cooling and dehumidifying the occupied space. Chilled water is produced by an air cooled ammonia water absorption chiller based on the highly efficient generator absorber heat ex changer (GAX) absorption cycle. It can automatically modulate its cooling capacity down to 50% for improved comfort, humidity control and operating efficiency at part load conditions. Natural gas supplies the main energy input to the absorption chiller. A small amount of electrical energy is required to drive the pumps and fans. The thermostat, indoor blower, chilled water coil and piping are to be field supplied.
4 II. Absorption Principle Comparison between conventional and VICOT GAX absorption chiller Conventional Absorption Chiller VICOT GAX Absorption Chiller Figure1 Figure2 III. GAX Absorption Cycle The highly efficient GAX cycle diagram is shown in Figure2 First, note that besides the five major components of the simple cycle, several heat exchangers have been added to attain the high efficiency performance. These include the Generator Absorber Heat Exchanger (GAX), the Adiabatic Section, the Generator Heat Exchanger (GHX), the Rectifier and the Subcooler. The increased efficiency of the GAX cycle is the result of achieving this simultaneous vapor generation and vapor absorption by internal exchange of heat. The vapor that is generated in the generator absorber heat exchanger saves the gas that would otherwise have to be used to generate it in a conventional generator.
5 IV. Major Component Description and Function Generator Heats and Distills Solution to Provide Ammonia Vapor (99.5%) and Weak Solution (4%). SCA/GAX Absorber Provides Suction to Evaporator Using Weak Solution as well as Heat Recovery. Solution Pump Pumps Strong Solution from Low to High Pressure. Condenser Rejects Heat and Provides Condensate. PTXV Provides Expansion of Ammonia and Controls the Refrigeration Effect (High efficiency expansion valve). Evaporator Accepts Heat Input to Liquid and Provides Vapor to Absorber Air Coil Condenser Portion Rejects Heat and Provides Condensate, Absorber Portion Completes Absorption of Ammonia and Rejects Heat. V. Features Patented Technology for First Ever Continuously Variable Speed Operation. Modular design and parallel multi unit connection can realize 5RT~40RT capacity range. 40TR groups can be centralized up to 200TR. Intelligent Controls for Load Matching for Optimal Efficiency. Can Produce Chilled Glycol To Temperatures of 8 C for Ice making. Efficient variable speed motor control technology minimizes electricity consumption and noise. Low NOx burner, Extremely Clean Burning. The true eco friendly air conditioning. Optional heating module for hot water supply in 24 hours. Stable operation in ambient temperature from 20 o C to 55 o C. Non Toxic Corrosion Inhibitor in refrigeration system.
6 VI. Performance curve Figure3 VII. Nomenclature V S A C N 005 A Refrigerant: A: Ammonia B: LiBr Capacity: 005 Single unit cooling capacity is 5RT. Module Number: N=1~8 Function: C: Cooling only Heat rejection type: A: Air cooled W: Water Energy source: S: Solar and Gas G: Gas V: VICOT
7 VIII. Technical Data Vicot Air Conditioning Co., Ltd. Item Cooling Capacity Cooling Adjustment Chilled Water Flow Model VGAC1005A VGAC2005A VGAC3005A VGAC4005A RT KW BTU/Hr BTU/Hr 36000~ ~ ~ ~ m 3 /h Water Pipe In 1 1/4 Gas Pipe In 1/2 Refrigerant Dimension mm 1539*916*1565 Power Supply Power Input MR717 Weight kg NOTE: 1. The test conditions of the unit: Ambient temperature=35 o C; Chilled water inlet =12 o C; chilled water outlet =7 o C 2. Adjust range for the unit is the range of its stepless inverter. 3. For natural gas, the maximum supply pressure to the unit must not exceed 14.0 in.w.c. The minimum gas pressure is 5.0 in.w.c. Higher gas pressures can damage or make inoperative the gas regulator. 2* 1Ph 220V 50Hz 3* 4* KW Weight kg Item Cooling Capacity Cooling Adjustment Chilled Water Flow Model VGAC5005A VGAC6005A VGAC7005A VGAC8005A RT KW BTU/Hr BTU/Hr 36000~ ~ ~ ~ m 3 /h Water Pipe In 1 1/4 Gas Pipe In 1/2 Refrigerant Dimensions Power Supply mm 5* 6* MR717 1Ph 220V 50Hz 7* 8* PowerInput KW
8 IX. Dimensions Figure4 Figure5
9 X. Application The GAX chiller is usually installed in an air conditioning system that consists of chilled water distribution system and thermostat. The GAX chiller is installed in an air conditioning system very much like a conventional electric residential split system, as shown in Figure 5. The air cooled chiller must be located outdoors where it has free access to outdoor air for heat rejection. The chilled water coil is located indoors in the supply air plenum of a central air handler. Chilled water piping connects the GAX chiller with the indoor coil. Figure6
10 XI. Typical Chilled Water Piping Chilled water piping can be PVC, polyethylene, galvanized steel pipe, copper or other materials, depending on the nature of the installation. Typical fittings at the chiller unit are shown in Figure6.It is recommended that a ball valve be installed in ach line for flow adjustment and shut off. Pressure taps are required for adjusting the flow rate as a function of the evaporator water side pressure drop. Figure7
11
12
Industrial Heat Pumped Hot Water
Industrial Heat Pumped Hot Water Ellen Makar Energy Concepts Company 1 Introduction Thermally powered absorption cycle provides chilling and heating Produces hot water and chilled water simultaneously,
More informationBuilding air conditioning systems using Ice-Cel thermal storage can be designed which cost little or no more than conventional chiller-only systems.
WHY THERMAL STORAGE? Thermal storage is a technology that has come of age. It meets today's need for flexible energy management. Whether you're the owner of a large building, a school executive, a hospital
More informationSYSTEM DESIGN REQUIREMENTS
P a g e 1 SYSTEM DESIGN REQUIREMENTS WFC-S SERIES WATER-FIRED SINGLE-EFFECT ABSORPTION CHILLERS / CHILLER-HEATERS Yazaki WFC-S Series water-fired chillers and chiller-heaters are available with nominal
More informationNovel Liquid Desiccant Systems
Novel Liquid Desiccant Systems -For more comfortable and energy efficient air-conditioning applications Breeding a better environment into your building Air T&D Pte. Ltd Introduction We provide the most
More informationSMALL AIR COOLED CONDENSERS
Catalog KM-KDX-0816A Supersedes Catalog KM-KDS-1014A UNICON SMALL AIR COOLED CONDENSERS 2 Unicon Efficient and Reliable Kramer s Remote Air Cooled Condensers innovative design provides a wide array of
More informationAir Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN
Air Conditioning Clinic Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN Absorption Water Chillers One of the Equipment Series A publication of The Trane Company Worldwide Applied Systems
More informationMethod to test HVAC equipment at part load conditions
IPLV Method to test HVAC equipment at part load conditions For water cooled chillers: 100% load ( % hrs) + 75% ( Hrs ) + 50% ( Hrs ) + 25% ( Hrs ) = IPLV value Manufacturer can favor this number by tweaking
More informationDEVELOPMENT OF THE WORLD S FIRST SMALL-SCALE TWO-STAGE ABSORPTION CHILLER/HEATER/HOT-WATER SYSTEM
DEVELOPMENT OF THE WORLD S FIRST SMALL-SCALE TWO-STAGE ABSORPTION CHILLER/HEATER/HOT-WATER SYSTEM Zhang Yue, CEO Broad Air Conditioning, Ltd., Changsha, China Ronald Fiskum, Integrated Energy Systems Project
More informationCHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM
111 CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM 7.1 INTRODUCTION Energy is the primary component to run any system in the world. According to
More informationAquaflair TRAC-TRAF-TRAH
Aquaflair TRAC-TRAF-TRAH 110 400 kw Air-cooled chillers, free-cooling chillers and heat pumps for mission critical applications Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors
More informationACMVTECH HIGH EFFICIENCY UNITARY AHU
HIGH EFFICIENY UNITARY AHU 50 / 60 Hz R-134A, R407c R-407F, R-410A ACMVTECH HIGH EFFICIENCY UNITARY AHU WATER COOLED CONDENSERS VARIABLE and CONSTANT SPEED VSD FANS ; VSD COMPRESSORS ACMCVTECH UNITARY
More informationMECHANICAL SERVICES 101. Ian White
MECHANICAL SERVICES 101 Ian White Contents 1. Ventilation 2. Heat Gains & Losses 3. Heating Ventilation Air Conditioning (HVAC) Systems What are Building Services Building Services incorporate all aspects
More informationAIR COOLED CONDENSERS
G JUMBO AIR COOLED CONDENSERS Capacity Range - 252.9kW to 7.0kW(15KTD) High Efficient Coil design with Latest Heat Transfer Technology New Aesthetic design with Round Corners The High Qualify German Motors
More informationThe ultimate in air handling units: directly and indirectly fired
AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationEnvironmentally friendly refrigeration systems for industrial use
compindustri Environmentally friendly refrigeration systems for industrial use CO ² refrigeration systems of the future GENERAL INFORMATION compindustri More than 10 years of development of refrigeration
More informationImplementation of Energy Saving measures in Existing Buildings
Building Surveyors Conference on Building a Green and Sustainable Future Implementation of Energy Saving measures in Existing Buildings 5 September 2009 Energy Efficient / Environmental Friendly Products
More informationThe ultimate in air handling units: directly and indirectly fired
KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationPerformance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers
e-issn 2455 1392 Volume 2 Issue 5, May 2016 pp. 108-116 Scientific Journal Impact Factor : 3.468 http://www.ijcter.com Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl
More informationThe ultimate in air handling units: directly and indirectly fired
KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationThe ultimate in air handling units: directly and indirectly fired
AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationProcess glycol chillers
Process glycol chillers The most advanced solutions in refrigeration technology. According to normative EN378 y F-Gas Compact chillers for outdoor installation Natural refrigerant Integrated hydraulic
More informationMODELS LIST. Nominal Capacity RT
1. MODELS LIST. NOMENCLATURE 3. FEATURES 4. PRODUCT DATA 5. PERFORMANCE CORRECTION 6. ANTIFREEZE 7. INSTALLATION 8. ELECTRICAL DATA 9. SCHEMATIC WIRING DIAGRAM 10.MICROPROCESSOR CONTROLLER 11.APPLICATION
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More information3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?
Code No: RR410305 Set No. 1 IV B.Tech I Semester Regular Examinations, November 2006 REFRIGERATION & AIR CONDITIONING (Mechanical Engineering) Time: 3 hours Max Marks: 80 Answer any FIVE Questions All
More informationAir-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a
Air-Cooled Variable Speed Drive Screw Chillers Super Efficient Super Quiet Cooling Capacity Range 540-1405 kw R134a World s first low sound Air-Cooled variable speed drive screw chiller The recognition
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationGas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities
Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Capacities W E A R E F R I E N D L Y T O T H E E A R T H Gas Fired DOUBLE-EFFECT Chiller-Heater Absorption Principle Yazaki MG-Series
More informationCommercial and Technical Data
Chillers Commercial and Technical Data Air Cooled Single Circuit Condensing Unit» Wide capacity range (120 kw - 490 kw)» One refrigerant circuit with single screw compressor» Two sound versions available»
More information150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER
GUIDE SPECIFICATIONS 150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER HEATER 1. General Description The Contractor shall furnish and install (Qty) Yazaki model CH- Gas Fired,
More informationGAS ABSORPTION HEAT PUMP
G A H P VV GAS ABSORPTION HEAT PUMP Water Cooled Gas Fired Absorption Heat Pump > Make a choice to build up the future G A H P VV GAS ABSORPTION HEAT PUMP WATER COOLED GAS FIRED ABSORPTION HEAT T PUMP
More informationINTEGRATED SOLUTIONS BY ICE-CEL. Tube-In-Tank Ice Thermal Storage Systems. Products that perform...by people who care.
INTEGRATED SOLUTIONS BY ICE-CEL Tube-In-Tank Ice Thermal Storage Systems INTEGRATED SOLUTIONS BY Products that perform...by people who care. WHY THERMAL STORAGE? Thermal storage is a technology that has
More informationLeadership, Innovation, Advanced Technology Synergise Here!
Cooling Synergies Leadership, Innovation, Advanced Technology Synergise Here! 125 years of Engineering Innovation Kirloskar Chillers is proud to be a part of 125 years old Kirloskar Group. The diversified
More informationV4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer
V4 Plus Heat Recovery VRF Linda Lin Pre-sales Engineer VRF Line-up DC inverter VRFs 2-pipe 3-pipe Combinable Individual Watercooled Mini Heat recovery V5 X 8-88HP V4+S 8-64HP V4+I (side) 20-45kW V4+I (top)
More informationChillers. Technical Data. EWYD-BZ 250~580 kw
Chillers Technical Data A i r C o o l e d C h i l l e r w w w. d a i k i n. e u EWYD-BZ 250~580 kw Daikin Europe N.V. About Daikin Daikin has a worldwide reputation based on over 80 years experience in
More informationAir Conditioning and process cooling Energy Components at a Glance
Energy Components at a Glance What is it? A means of providing cooling with mechanical refrigeration equipment. Where is it found? Chilled water is found in many plants, non-existent in others. Essential
More informationRAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR
AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable
More informationDunham Bush Air Cooled Screw Chiller AFVX B 6SR Series
Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR
More informationA Complete Line Of Remote Rack Refrigeration Systems
A Complete Line Of Remote Rack Refrigeration Systems Choosing The Right Rack Refrigeration System DRS Series Dual Compressor Systems For combination cooler/freezer walk-ins, DRS systems provide a hermetic
More informationSingle Screw Ammonia Heat Pumps. Harness Your Heat... Don t Reject It
Single Screw Ammonia Heat Pumps Harness Your Heat... Don t Reject It Harness Your Heat Don't Reject It Industrial processes consume considerable energy from two primary sources in the production of their
More information> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories
> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base
More informationModular Water Cooled Water Chiller
Modular Water Cooled Water Chiller Shandong Vicot Air Conditioning Co., Ltd. Shandong Vicot Air Conditioning Co., Ltd. is one of the major players in the Chinese air conditioning industry, specialized
More informationAppendix 13. Categories of Cooling and Heating systems
EcoShopping - Energy efficient & Cost competitive retrofitting solutions for Shopping buildings Co-funded by the European Commission within the 7 th Framework Programme. Grant Agreement no: 609180. 2013-09-01
More informationNFZP Variable Refrigerant Flow Guide Specification
PART 1 - GENERAL 1.01 SECTION INCLUDES SECTION 23 81 29 VARIABLE REFRIGERANT FLOW HVAC SYSTEM A. (VRF) HVAC system includes: 1. Outdoor/Condensing unit(s): a. Size Range: 14 Tons Nominal b. YANMAR VRF
More informationINTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012
HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O INTRODUCTION HVAC systems or Heating, Ventilating and Air-Conditioning systems control the environment for people and equipment in our facilities.
More informationREFRIGERATION AND AIR CONDITIONING
REFRIGERATION AND AIR CONDITIONING SECOND EDITION S.N. Sapali Professor of Mechanical Engineering College of Engineering, Pune Delhi-110092 2014 REFRIGERATION AND AIR CONDITIONING, Second Edition S.N.
More informationNC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection
NC NC Series NG NG Series Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection NC NC SERIES PERFORMANCE DATA Model Capacity Min. Circuit Ampacity (MCA)
More informationChapter-8 Capacity Control of Refrigeration Systems
Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems ၈.၁ Compressor Control Chiller Control and Chilled Water Plant Control Refrigeration system control
More informationSECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences
More informationHeat Recovery Unit Air Cooled Condenser for Precise Temperature & Humidity Control
Energy saving product! Heat Recovery Unit Air Cooled Condenser for Precise Temperature & Humidity Control ENERCOV EV Series, The best solution to improve room humidity and temperature as per your requirement.
More informationInverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com
Inverter Ducted Split Air Source Heat Pump System with Inverter Drive Technology Simply Smart The robust Bosch Inverter Ducted Split air-source heat pump system utilizes just the right amount of energy
More informationGP SERIES Packaged Chillers
Material Handling Process Cooling Temperature Control Size Reduction Temperature Control Process Cooling Material Handling Size Reduction GP SERIES Packaged Chillers Precision Comprehensive Engineered
More informationVRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group
VRF D4 PLUS System Digital Scroll Series GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating
More informationEN aquatech.piovan.com
EN aquatech.piovan.com Refrigeration Technologies: scroll-compressor chillers The scroll compressor is the most suitable component for the small and medium duty requirements in the industrial applications.
More informationGas-Fired Double-Effect Chiller-Heater
Gas-Fired Double-Effect Chiller-Heater CH-K Series: 30, 40, 50, 60, 80, 100 RT Cooling with Standard Heating Capacities W E A R E F R I E N D L Y T O T H E E A R T H Gas-Fired Double-Effect Chiller-Heater
More informationProduct Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz
Product Data GEMINI SELECT 09DPS018-030,09DPM035-130 Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz 18 to 130 Nominal Tons (63 to 457 Nominal kw) a38-7096 09DPS030 UNIT WITH LOW SOUND OPTION
More informationGuidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems If you're a designer or a BCA, this guidance on the energy efficiency of HVAC systems in commercial buildings may
More informationHow to Select and Size a Chiller
How to Select and Size a Chiller -What is process cooling -Which chiller type is best for your application Dimplex Thermal Solutions FABTECH November 9-12, 2015 What is an Industrial Process Chiller? Uses
More informationSystem-CoolAC. Bharatividyapeeth College of Engineering, Deekshant Bharti Scholar, New Delhi, India
A Novel Design of Low Cost Domestic Cooling System-CoolAC Abhishek Gandhar Associate Prof., abhishek.gandhar@gmail.com Deekshant Bharti bravo9421@gmail.com Aditya Jain adityajn710@gmailcom Shiv Wadhwa
More informationAircooled Units. AirPLUS Aircooled scroll chiller. Freecooling options: liquid control. Freecooling options: fans control. Noise \\ Efficiency options
2017 Products Foreword Felzer is one of the Scandinavian & BS leading providers of heating, ventilation, air conditioning and refrigeration solutions for industrial, commercial and residential applications.
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY
More informationJCseries EVAPORATIVE CONDENSER. engineering data
JCseries EVAPORATIVE CONDENSER engineering data Recold JC Series Evaporative Condenser Contents 2 Construction... 3 Schematic... 4 Engineering Data... 5 Selection Procedure... 6-9 Multi-Circuited Selection
More informationINTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies
Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER
More informationSHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C
SHERPA Th e multifunctional air-water split heat pump. PATENTED TECHNOLOGY The combination of an inverter air-water heat pump together with a water-water heat pump allows heating/ and high temperature
More informationBN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR Air-Cooled Condenser. with Microchannel Coil Technology Models NRG NRJ
BN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR 2015 Air-Cooled Condenser with Microchannel Coil Technology Models NRG NRJ Table of Contents Nomenclature... 2 Features & Benefits... 3 Capacity and Specifications...
More informationNew standard in compressed air treatment, providing Energy Savings up to 99%
PCM Series Specification for APAC Model Flow Capacity (Nm 3 /min) Pressure Dew Point ( ) Power Consumption (kw) Power Supply (V/Ph/Hz) Inlet/Outlet Connections Weight (kg) Dimensions (H x W x D mm) Refrigerants
More informationCentrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series
Centrifugal Chiller High Efficiency GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency Centrifugal Chiller HC-F-GFG-SSC Series (Super High Efficiency Type) HC-F-GXG-S
More informationUNIT 4: REFRIGERATION PRINCIPLE
UNIT 4: REFRIGERATION PRINCIPLE 4.1 Introduction i. Buildings are essentially enclosed spaces designed for the purpose of accommodating occupants and their activities. ii. Thermal comfort is incorporated
More informationDehumidification and ventilation for residential, industrial radiant systems and swimming pools
Dehumidification and ventilation for residential, industrial radiant systems and swimming pools HiDew is proud to present a complete range of dehumidifiers for radiant cooling systems and high performance
More informationDesign & Fabrication of Hybrid Cooler
IJIRST International Journal for Innovative Research in Science & Technology Volume 2 Issue 11 April 2016 ISSN (online): 2349-6010 Design & Fabrication of Hybrid Cooler Shashank Chauragade Mukul Kshirsagar
More information30GT FLOTRONIC AIR-COOLED CHILLERS
30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed
More informationInstitute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING
Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad- 500 043 B.Tech (III II SEM) MECHANICAL ENGINEERING REFRIGERATION AND AIR CONDITIONING Prepared by, Dr. CH V K N S N Moorthy, Professor
More informationMechanical Systems Mechanical Systems
VING IMPRO ALLY NATUR Mechanical Systems 2017 Mechanical Systems E RMANC PERFO Content Rack Units Racks Units Opti OL Indoor Mini Compact OLtec EVO Maxi Compact Flexi Optivell Innovell Econvell Maxivell
More informationCertification Programs, Standards,
Certification Programs, Standards, and Guidelines Visit the AHRI Directory www.ahridirectory.org View and download AHRI Standards and Guidelines www.ahrinet.org Certification Programs, Standards, and
More informationOptimised for high ambient operation (up to 55 C ambient) EWAD-MZ. Air cooled chiller
Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ Air cooled chiller Why choose Daikin? Daikin were the among first to pioneer the use of inverters in air cooled screw chillers. And today,
More informationCMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N
E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,
More informationMECCI Engineers. Institute of Engineering Design & Research
MECCI Engineers Institute of Engineering Design & Research (An ISO 9001:2015 DAC International Certification for EPC Consulting, Engineering Project & Training Company) HVAC Design Course Content For Regular
More informationSeries. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost
LL Chillers and Outdoor Mechanical Rooms Air-Cooled Features: Air-cooled condenser chillers with capacities from 35-345 tons Evaporative-cooled condenser chillers with capacities from 35-540 tons Variable
More informationINSTITUTE FOR ENVIRONMENTAL RESEARCH & SUSTAINABLE DEVELOPMENT NATIONAL OBSERVATORY OF ATHENS (NOA)
1 SOLAR COOLING An Overview of European Applications & Design Guidelines Costas Balaras, Ph.D. Member ASHRAE, Mechanical Engineer, Research Director GRoup Energy Conservation (GR.E.C.) INSTITUTE FOR ENVIRONMENTAL
More informationSummary Comparison of Simulation Program Features
Summary Comparison of Simulation Program Features FEATURE DOE2.2 equest TRACE 700 HAP Public/Proprietary Public Domain Proprietary Proprietary Proprietary Simulation Method 8760 hours 8760 hours 8760 hours
More informationKawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto
Kawasaki centrifugal chiller using water as a refrigerant Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto Contents 1. Introduction of MiZTURBO 2. Study of CO 2 emissions
More informationcommercial refrigeration products
commercial refrigeration products Evaporators Condensing Units Condensers Air Handlers Fluid Coolers Coils NOTHING BEATS A BALLY Evaporators EC MOTORS Available Half Round Low velocity Two-way low profile
More informationInverter Ducted Split Air Source Heat Pump System with Inverter Drive Technology
Inverter Ducted Split Air Source Heat Pump System with Inverter Drive Technology The robust Bosch Inverter Ducted Split air-source heat pump system utilizes just the right amount of energy to achieve ultimate
More informationPKTEWC. Electric Wine Cooler. Wine Chilling Refrigerator MODEL:
by PKTEWC Electric Wine Cooler Wine Chilling Refrigerator MODEL: PKTEWC0 PKTEWC0 PKTEWC1 PKTEWC10 PKTEWC1 PKTEWC10 PKTEWCDS10 PKTEWCDS10 PKTECC0 Bottle Capacity Bottle Capacity 1 Bottle Capacity 1 Bottle
More informationAPS Chiller Seminar. Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017
APS Chiller Seminar Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017 Agenda for today Refrigeration Cycle Chiller Types and Refrigerants Compressor Styles Chilled Water Pumping Systems
More informationEHH SERIES DRAW THROUGH FAN COILS CFM
EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE
More informationElectric Wine Cooler. Wine Chilling Refrigerator MODEL:
by Electric Wine Cooler Wine Chilling Refrigerator MODEL: PKTEWC08 PKTEWC80 PKTEWC12 PKTEWC120 PKTEWC18 PKTEWC180 PKTEWCDS1802 PKTEWCDS1805 PKTECC40 8 Bottle Capacity 8 Bottle Capacity 12 Bottle Capacity
More informations. Properties for R134a are as follows : Saturated R-134a Superheated R-134a
CHAPTER 9 REFRIGERATION & AIR-CONDITIONING YEAR 2012 ONE MARK Common Data For Q. 1 and Q.2 A refrigerator operates between 120 kpa and 800 kpa in an ideal vapour compression cycle with R-134a as the refrigerant.
More informationINSERT NEW PHOTO HERE
INSERT NEW PHOTO HERE Photo by Chuck Berray Photo by: Cassandra Cerny, GVEA Alaska Energy Authority Absorption Chilling 101 Devany Plentovich 11/2017 2 Learning Objectives Understand: the basic operation
More informationPS & GPS SERIES PARALLEL RACK REFRIGERATION SYSTEMS
PS & GPS SERIES PARALLEL RACK REFRIGERATION SYSTEMS PS Series Parallel Racks For those who want to maximize energy savings and have full control of an entire refrigeration network within a facility, PS
More informationPLEXUS. Marine HVAC Components for Boats and Yachts CATALOGUE
PLEXUS Marine HVAC Components for Boats and Yachts CATALOGUE 08/2017 1 PLEXUS CATALOGUE 08/2017 Self Contained ASC MAP Series...2 Split ASP System ASP Series... 4 Water Chiller AWC Series - Single Chiller...
More informationMULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw
Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01
More informationPrecise Temperature Control; Compact Footprint
Precise Temperature Control; Compact Footprint The Conair EP1 Series Portable Chillers are designed for 1 to 3 ton applications. Available as air-cooled or water-cooled, with pump sizes from 1/4 to 3 Hp
More informationCHAPTER 1 INTRODUCTION
1 CHAPTER 1 INTRODUCTION 1.1 Background The science which deals with creating a controlled climate in indoor space is called air conditioning. Earlier days the air-conditioning was treated as a luxury,
More informationAIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw
COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation
More informationISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 7, Issue 11, May 2018
Absorption chiller with cooling and heating for energy saving and environment friendly Yongjian Gu, Ph.D., P.E. Department of Marine Engineering United States Merchant Marine Academy 300 Steamboat Rd,
More informationCapacity: 1.5 to 6.0 Ton
VACPB1 Series Wall Mount Explosion Proof Air Conditioner and Room Pressurization System Hazardous Location N.E.C. and I.E.C. Approved 50 Hertz Models 60 Hertz, High Ambient, & Custom Designs Available
More informationTHE CHEAPEST WAY TO HEAT YOUR WATER
THE CHEAPEST WAY TO HEAT YOUR WATER 2 YOU LL GET IN HOT WATER, BUT NOT WITH YOUR POWER COMPANY INSTALLING EXCEED CAN SAVE YOU UP TO 66% ON YOUR HOT WATER HEATING * With Exceed s innovative Heat Pump Water
More informationAPPLICABILITY OF VRV/VRF HVAC SYSTEM A JUDICIOUS AND RATIONAL APPROACH
APPLICABILITY OF VRV/VRF HVAC SYSTEM A JUDICIOUS AND RATIONAL APPROACH KULDIP PESHIN CHIEF ENGINEER CENTRAL PUBLIC WORKS DEPARTMENT CHENNAI 600090 ABSTRACT Use of Variable Refrigerant Volume (VRV)/Variable
More informationInverter Swimming Pool Heat Pump
P Inverter Swimming Pool Heat Pump Content I. Application... 2 II. Features... 2 III. Technical Parameter... 3 IV. Dimension... 4 V. Installation instruction... 5 VI. Operation instruction... 9 VII. Testing...