Vicot Air Conditioning Co., Ltd. CONTENT

Size: px
Start display at page:

Download "Vicot Air Conditioning Co., Ltd. CONTENT"

Transcription

1

2 CONTENT I. Introduction 2 II. Absorption Principle 3 III. GAX Absorption Cycle 3 IV. Major Component Description and Function 4 V. Features 4 VI. Performance curve 5 VII. Nomenclature 5 VIII. Technical Data 6 IX. Dimensions 7 X. Application 8 XI. Typical Chilled Water Piping 9 AIR COOLED GAS FIRED ABSORPTION CHILLER

3 I. Introduction The Vicot gas fired water chiller is a high efficiency gas fired water chiller for residential and light commercial air conditioning duty. The chiller is designed to be installed outdoors and connected with a chilled water coil located in the indoor air handling system for cooling and dehumidifying the occupied space. Chilled water is produced by an air cooled ammonia water absorption chiller based on the highly efficient generator absorber heat ex changer (GAX) absorption cycle. It can automatically modulate its cooling capacity down to 50% for improved comfort, humidity control and operating efficiency at part load conditions. Natural gas supplies the main energy input to the absorption chiller. A small amount of electrical energy is required to drive the pumps and fans. The thermostat, indoor blower, chilled water coil and piping are to be field supplied.

4 II. Absorption Principle Comparison between conventional and VICOT GAX absorption chiller Conventional Absorption Chiller VICOT GAX Absorption Chiller Figure1 Figure2 III. GAX Absorption Cycle The highly efficient GAX cycle diagram is shown in Figure2 First, note that besides the five major components of the simple cycle, several heat exchangers have been added to attain the high efficiency performance. These include the Generator Absorber Heat Exchanger (GAX), the Adiabatic Section, the Generator Heat Exchanger (GHX), the Rectifier and the Subcooler. The increased efficiency of the GAX cycle is the result of achieving this simultaneous vapor generation and vapor absorption by internal exchange of heat. The vapor that is generated in the generator absorber heat exchanger saves the gas that would otherwise have to be used to generate it in a conventional generator.

5 IV. Major Component Description and Function Generator Heats and Distills Solution to Provide Ammonia Vapor (99.5%) and Weak Solution (4%). SCA/GAX Absorber Provides Suction to Evaporator Using Weak Solution as well as Heat Recovery. Solution Pump Pumps Strong Solution from Low to High Pressure. Condenser Rejects Heat and Provides Condensate. PTXV Provides Expansion of Ammonia and Controls the Refrigeration Effect (High efficiency expansion valve). Evaporator Accepts Heat Input to Liquid and Provides Vapor to Absorber Air Coil Condenser Portion Rejects Heat and Provides Condensate, Absorber Portion Completes Absorption of Ammonia and Rejects Heat. V. Features Patented Technology for First Ever Continuously Variable Speed Operation. Modular design and parallel multi unit connection can realize 5RT~40RT capacity range. 40TR groups can be centralized up to 200TR. Intelligent Controls for Load Matching for Optimal Efficiency. Can Produce Chilled Glycol To Temperatures of 8 C for Ice making. Efficient variable speed motor control technology minimizes electricity consumption and noise. Low NOx burner, Extremely Clean Burning. The true eco friendly air conditioning. Optional heating module for hot water supply in 24 hours. Stable operation in ambient temperature from 20 o C to 55 o C. Non Toxic Corrosion Inhibitor in refrigeration system.

6 VI. Performance curve Figure3 VII. Nomenclature V S A C N 005 A Refrigerant: A: Ammonia B: LiBr Capacity: 005 Single unit cooling capacity is 5RT. Module Number: N=1~8 Function: C: Cooling only Heat rejection type: A: Air cooled W: Water Energy source: S: Solar and Gas G: Gas V: VICOT

7 VIII. Technical Data Vicot Air Conditioning Co., Ltd. Item Cooling Capacity Cooling Adjustment Chilled Water Flow Model VGAC1005A VGAC2005A VGAC3005A VGAC4005A RT KW BTU/Hr BTU/Hr 36000~ ~ ~ ~ m 3 /h Water Pipe In 1 1/4 Gas Pipe In 1/2 Refrigerant Dimension mm 1539*916*1565 Power Supply Power Input MR717 Weight kg NOTE: 1. The test conditions of the unit: Ambient temperature=35 o C; Chilled water inlet =12 o C; chilled water outlet =7 o C 2. Adjust range for the unit is the range of its stepless inverter. 3. For natural gas, the maximum supply pressure to the unit must not exceed 14.0 in.w.c. The minimum gas pressure is 5.0 in.w.c. Higher gas pressures can damage or make inoperative the gas regulator. 2* 1Ph 220V 50Hz 3* 4* KW Weight kg Item Cooling Capacity Cooling Adjustment Chilled Water Flow Model VGAC5005A VGAC6005A VGAC7005A VGAC8005A RT KW BTU/Hr BTU/Hr 36000~ ~ ~ ~ m 3 /h Water Pipe In 1 1/4 Gas Pipe In 1/2 Refrigerant Dimensions Power Supply mm 5* 6* MR717 1Ph 220V 50Hz 7* 8* PowerInput KW

8 IX. Dimensions Figure4 Figure5

9 X. Application The GAX chiller is usually installed in an air conditioning system that consists of chilled water distribution system and thermostat. The GAX chiller is installed in an air conditioning system very much like a conventional electric residential split system, as shown in Figure 5. The air cooled chiller must be located outdoors where it has free access to outdoor air for heat rejection. The chilled water coil is located indoors in the supply air plenum of a central air handler. Chilled water piping connects the GAX chiller with the indoor coil. Figure6

10 XI. Typical Chilled Water Piping Chilled water piping can be PVC, polyethylene, galvanized steel pipe, copper or other materials, depending on the nature of the installation. Typical fittings at the chiller unit are shown in Figure6.It is recommended that a ball valve be installed in ach line for flow adjustment and shut off. Pressure taps are required for adjusting the flow rate as a function of the evaporator water side pressure drop. Figure7

11

12

Industrial Heat Pumped Hot Water

Industrial Heat Pumped Hot Water Industrial Heat Pumped Hot Water Ellen Makar Energy Concepts Company 1 Introduction Thermally powered absorption cycle provides chilling and heating Produces hot water and chilled water simultaneously,

More information

Building air conditioning systems using Ice-Cel thermal storage can be designed which cost little or no more than conventional chiller-only systems.

Building air conditioning systems using Ice-Cel thermal storage can be designed which cost little or no more than conventional chiller-only systems. WHY THERMAL STORAGE? Thermal storage is a technology that has come of age. It meets today's need for flexible energy management. Whether you're the owner of a large building, a school executive, a hospital

More information

SYSTEM DESIGN REQUIREMENTS

SYSTEM DESIGN REQUIREMENTS P a g e 1 SYSTEM DESIGN REQUIREMENTS WFC-S SERIES WATER-FIRED SINGLE-EFFECT ABSORPTION CHILLERS / CHILLER-HEATERS Yazaki WFC-S Series water-fired chillers and chiller-heaters are available with nominal

More information

Novel Liquid Desiccant Systems

Novel Liquid Desiccant Systems Novel Liquid Desiccant Systems -For more comfortable and energy efficient air-conditioning applications Breeding a better environment into your building Air T&D Pte. Ltd Introduction We provide the most

More information

SMALL AIR COOLED CONDENSERS

SMALL AIR COOLED CONDENSERS Catalog KM-KDX-0816A Supersedes Catalog KM-KDS-1014A UNICON SMALL AIR COOLED CONDENSERS 2 Unicon Efficient and Reliable Kramer s Remote Air Cooled Condensers innovative design provides a wide array of

More information

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN Air Conditioning Clinic Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN Absorption Water Chillers One of the Equipment Series A publication of The Trane Company Worldwide Applied Systems

More information

Method to test HVAC equipment at part load conditions

Method to test HVAC equipment at part load conditions IPLV Method to test HVAC equipment at part load conditions For water cooled chillers: 100% load ( % hrs) + 75% ( Hrs ) + 50% ( Hrs ) + 25% ( Hrs ) = IPLV value Manufacturer can favor this number by tweaking

More information

DEVELOPMENT OF THE WORLD S FIRST SMALL-SCALE TWO-STAGE ABSORPTION CHILLER/HEATER/HOT-WATER SYSTEM

DEVELOPMENT OF THE WORLD S FIRST SMALL-SCALE TWO-STAGE ABSORPTION CHILLER/HEATER/HOT-WATER SYSTEM DEVELOPMENT OF THE WORLD S FIRST SMALL-SCALE TWO-STAGE ABSORPTION CHILLER/HEATER/HOT-WATER SYSTEM Zhang Yue, CEO Broad Air Conditioning, Ltd., Changsha, China Ronald Fiskum, Integrated Energy Systems Project

More information

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM 111 CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM 7.1 INTRODUCTION Energy is the primary component to run any system in the world. According to

More information

Aquaflair TRAC-TRAF-TRAH

Aquaflair TRAC-TRAF-TRAH Aquaflair TRAC-TRAF-TRAH 110 400 kw Air-cooled chillers, free-cooling chillers and heat pumps for mission critical applications Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors

More information

ACMVTECH HIGH EFFICIENCY UNITARY AHU

ACMVTECH HIGH EFFICIENCY UNITARY AHU HIGH EFFICIENY UNITARY AHU 50 / 60 Hz R-134A, R407c R-407F, R-410A ACMVTECH HIGH EFFICIENCY UNITARY AHU WATER COOLED CONDENSERS VARIABLE and CONSTANT SPEED VSD FANS ; VSD COMPRESSORS ACMCVTECH UNITARY

More information

MECHANICAL SERVICES 101. Ian White

MECHANICAL SERVICES 101. Ian White MECHANICAL SERVICES 101 Ian White Contents 1. Ventilation 2. Heat Gains & Losses 3. Heating Ventilation Air Conditioning (HVAC) Systems What are Building Services Building Services incorporate all aspects

More information

AIR COOLED CONDENSERS

AIR COOLED CONDENSERS G JUMBO AIR COOLED CONDENSERS Capacity Range - 252.9kW to 7.0kW(15KTD) High Efficient Coil design with Latest Heat Transfer Technology New Aesthetic design with Round Corners The High Qualify German Motors

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

Environmentally friendly refrigeration systems for industrial use

Environmentally friendly refrigeration systems for industrial use compindustri Environmentally friendly refrigeration systems for industrial use CO ² refrigeration systems of the future GENERAL INFORMATION compindustri More than 10 years of development of refrigeration

More information

Implementation of Energy Saving measures in Existing Buildings

Implementation of Energy Saving measures in Existing Buildings Building Surveyors Conference on Building a Green and Sustainable Future Implementation of Energy Saving measures in Existing Buildings 5 September 2009 Energy Efficient / Environmental Friendly Products

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers e-issn 2455 1392 Volume 2 Issue 5, May 2016 pp. 108-116 Scientific Journal Impact Factor : 3.468 http://www.ijcter.com Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

Process glycol chillers

Process glycol chillers Process glycol chillers The most advanced solutions in refrigeration technology. According to normative EN378 y F-Gas Compact chillers for outdoor installation Natural refrigerant Integrated hydraulic

More information

MODELS LIST. Nominal Capacity RT

MODELS LIST. Nominal Capacity RT 1. MODELS LIST. NOMENCLATURE 3. FEATURES 4. PRODUCT DATA 5. PERFORMANCE CORRECTION 6. ANTIFREEZE 7. INSTALLATION 8. ELECTRICAL DATA 9. SCHEMATIC WIRING DIAGRAM 10.MICROPROCESSOR CONTROLLER 11.APPLICATION

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor? Code No: RR410305 Set No. 1 IV B.Tech I Semester Regular Examinations, November 2006 REFRIGERATION & AIR CONDITIONING (Mechanical Engineering) Time: 3 hours Max Marks: 80 Answer any FIVE Questions All

More information

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a Air-Cooled Variable Speed Drive Screw Chillers Super Efficient Super Quiet Cooling Capacity Range 540-1405 kw R134a World s first low sound Air-Cooled variable speed drive screw chiller The recognition

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities

Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Capacities W E A R E F R I E N D L Y T O T H E E A R T H Gas Fired DOUBLE-EFFECT Chiller-Heater Absorption Principle Yazaki MG-Series

More information

Commercial and Technical Data

Commercial and Technical Data Chillers Commercial and Technical Data Air Cooled Single Circuit Condensing Unit» Wide capacity range (120 kw - 490 kw)» One refrigerant circuit with single screw compressor» Two sound versions available»

More information

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER GUIDE SPECIFICATIONS 150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER HEATER 1. General Description The Contractor shall furnish and install (Qty) Yazaki model CH- Gas Fired,

More information

GAS ABSORPTION HEAT PUMP

GAS ABSORPTION HEAT PUMP G A H P VV GAS ABSORPTION HEAT PUMP Water Cooled Gas Fired Absorption Heat Pump > Make a choice to build up the future G A H P VV GAS ABSORPTION HEAT PUMP WATER COOLED GAS FIRED ABSORPTION HEAT T PUMP

More information

INTEGRATED SOLUTIONS BY ICE-CEL. Tube-In-Tank Ice Thermal Storage Systems. Products that perform...by people who care.

INTEGRATED SOLUTIONS BY ICE-CEL. Tube-In-Tank Ice Thermal Storage Systems. Products that perform...by people who care. INTEGRATED SOLUTIONS BY ICE-CEL Tube-In-Tank Ice Thermal Storage Systems INTEGRATED SOLUTIONS BY Products that perform...by people who care. WHY THERMAL STORAGE? Thermal storage is a technology that has

More information

Leadership, Innovation, Advanced Technology Synergise Here!

Leadership, Innovation, Advanced Technology Synergise Here! Cooling Synergies Leadership, Innovation, Advanced Technology Synergise Here! 125 years of Engineering Innovation Kirloskar Chillers is proud to be a part of 125 years old Kirloskar Group. The diversified

More information

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer V4 Plus Heat Recovery VRF Linda Lin Pre-sales Engineer VRF Line-up DC inverter VRFs 2-pipe 3-pipe Combinable Individual Watercooled Mini Heat recovery V5 X 8-88HP V4+S 8-64HP V4+I (side) 20-45kW V4+I (top)

More information

Chillers. Technical Data. EWYD-BZ 250~580 kw

Chillers. Technical Data. EWYD-BZ 250~580 kw Chillers Technical Data A i r C o o l e d C h i l l e r w w w. d a i k i n. e u EWYD-BZ 250~580 kw Daikin Europe N.V. About Daikin Daikin has a worldwide reputation based on over 80 years experience in

More information

Air Conditioning and process cooling Energy Components at a Glance

Air Conditioning and process cooling Energy Components at a Glance Energy Components at a Glance What is it? A means of providing cooling with mechanical refrigeration equipment. Where is it found? Chilled water is found in many plants, non-existent in others. Essential

More information

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable

More information

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR

More information

A Complete Line Of Remote Rack Refrigeration Systems

A Complete Line Of Remote Rack Refrigeration Systems A Complete Line Of Remote Rack Refrigeration Systems Choosing The Right Rack Refrigeration System DRS Series Dual Compressor Systems For combination cooler/freezer walk-ins, DRS systems provide a hermetic

More information

Single Screw Ammonia Heat Pumps. Harness Your Heat... Don t Reject It

Single Screw Ammonia Heat Pumps. Harness Your Heat... Don t Reject It Single Screw Ammonia Heat Pumps Harness Your Heat... Don t Reject It Harness Your Heat Don't Reject It Industrial processes consume considerable energy from two primary sources in the production of their

More information

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base

More information

Modular Water Cooled Water Chiller

Modular Water Cooled Water Chiller Modular Water Cooled Water Chiller Shandong Vicot Air Conditioning Co., Ltd. Shandong Vicot Air Conditioning Co., Ltd. is one of the major players in the Chinese air conditioning industry, specialized

More information

Appendix 13. Categories of Cooling and Heating systems

Appendix 13. Categories of Cooling and Heating systems EcoShopping - Energy efficient & Cost competitive retrofitting solutions for Shopping buildings Co-funded by the European Commission within the 7 th Framework Programme. Grant Agreement no: 609180. 2013-09-01

More information

NFZP Variable Refrigerant Flow Guide Specification

NFZP Variable Refrigerant Flow Guide Specification PART 1 - GENERAL 1.01 SECTION INCLUDES SECTION 23 81 29 VARIABLE REFRIGERANT FLOW HVAC SYSTEM A. (VRF) HVAC system includes: 1. Outdoor/Condensing unit(s): a. Size Range: 14 Tons Nominal b. YANMAR VRF

More information

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012 HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O INTRODUCTION HVAC systems or Heating, Ventilating and Air-Conditioning systems control the environment for people and equipment in our facilities.

More information

REFRIGERATION AND AIR CONDITIONING

REFRIGERATION AND AIR CONDITIONING REFRIGERATION AND AIR CONDITIONING SECOND EDITION S.N. Sapali Professor of Mechanical Engineering College of Engineering, Pune Delhi-110092 2014 REFRIGERATION AND AIR CONDITIONING, Second Edition S.N.

More information

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection NC NC Series NG NG Series Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection NC NC SERIES PERFORMANCE DATA Model Capacity Min. Circuit Ampacity (MCA)

More information

Chapter-8 Capacity Control of Refrigeration Systems

Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems ၈.၁ Compressor Control Chiller Control and Chilled Water Plant Control Refrigeration system control

More information

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012 SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences

More information

Heat Recovery Unit Air Cooled Condenser for Precise Temperature & Humidity Control

Heat Recovery Unit Air Cooled Condenser for Precise Temperature & Humidity Control Energy saving product! Heat Recovery Unit Air Cooled Condenser for Precise Temperature & Humidity Control ENERCOV EV Series, The best solution to improve room humidity and temperature as per your requirement.

More information

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com Inverter Ducted Split Air Source Heat Pump System with Inverter Drive Technology Simply Smart The robust Bosch Inverter Ducted Split air-source heat pump system utilizes just the right amount of energy

More information

GP SERIES Packaged Chillers

GP SERIES Packaged Chillers Material Handling Process Cooling Temperature Control Size Reduction Temperature Control Process Cooling Material Handling Size Reduction GP SERIES Packaged Chillers Precision Comprehensive Engineered

More information

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group VRF D4 PLUS System Digital Scroll Series GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating

More information

EN aquatech.piovan.com

EN aquatech.piovan.com EN aquatech.piovan.com Refrigeration Technologies: scroll-compressor chillers The scroll compressor is the most suitable component for the small and medium duty requirements in the industrial applications.

More information

Gas-Fired Double-Effect Chiller-Heater

Gas-Fired Double-Effect Chiller-Heater Gas-Fired Double-Effect Chiller-Heater CH-K Series: 30, 40, 50, 60, 80, 100 RT Cooling with Standard Heating Capacities W E A R E F R I E N D L Y T O T H E E A R T H Gas-Fired Double-Effect Chiller-Heater

More information

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz Product Data GEMINI SELECT 09DPS018-030,09DPM035-130 Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz 18 to 130 Nominal Tons (63 to 457 Nominal kw) a38-7096 09DPS030 UNIT WITH LOW SOUND OPTION

More information

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems If you're a designer or a BCA, this guidance on the energy efficiency of HVAC systems in commercial buildings may

More information

How to Select and Size a Chiller

How to Select and Size a Chiller How to Select and Size a Chiller -What is process cooling -Which chiller type is best for your application Dimplex Thermal Solutions FABTECH November 9-12, 2015 What is an Industrial Process Chiller? Uses

More information

System-CoolAC. Bharatividyapeeth College of Engineering, Deekshant Bharti Scholar, New Delhi, India

System-CoolAC. Bharatividyapeeth College of Engineering, Deekshant Bharti Scholar, New Delhi, India A Novel Design of Low Cost Domestic Cooling System-CoolAC Abhishek Gandhar Associate Prof., abhishek.gandhar@gmail.com Deekshant Bharti bravo9421@gmail.com Aditya Jain adityajn710@gmailcom Shiv Wadhwa

More information

Aircooled Units. AirPLUS Aircooled scroll chiller. Freecooling options: liquid control. Freecooling options: fans control. Noise \\ Efficiency options

Aircooled Units. AirPLUS Aircooled scroll chiller. Freecooling options: liquid control. Freecooling options: fans control. Noise \\ Efficiency options 2017 Products Foreword Felzer is one of the Scandinavian & BS leading providers of heating, ventilation, air conditioning and refrigeration solutions for industrial, commercial and residential applications.

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

JCseries EVAPORATIVE CONDENSER. engineering data

JCseries EVAPORATIVE CONDENSER. engineering data JCseries EVAPORATIVE CONDENSER engineering data Recold JC Series Evaporative Condenser Contents 2 Construction... 3 Schematic... 4 Engineering Data... 5 Selection Procedure... 6-9 Multi-Circuited Selection

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C SHERPA Th e multifunctional air-water split heat pump. PATENTED TECHNOLOGY The combination of an inverter air-water heat pump together with a water-water heat pump allows heating/ and high temperature

More information

BN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR Air-Cooled Condenser. with Microchannel Coil Technology Models NRG NRJ

BN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR Air-Cooled Condenser. with Microchannel Coil Technology Models NRG NRJ BN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR 2015 Air-Cooled Condenser with Microchannel Coil Technology Models NRG NRJ Table of Contents Nomenclature... 2 Features & Benefits... 3 Capacity and Specifications...

More information

New standard in compressed air treatment, providing Energy Savings up to 99%

New standard in compressed air treatment, providing Energy Savings up to 99% PCM Series Specification for APAC Model Flow Capacity (Nm 3 /min) Pressure Dew Point ( ) Power Consumption (kw) Power Supply (V/Ph/Hz) Inlet/Outlet Connections Weight (kg) Dimensions (H x W x D mm) Refrigerants

More information

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency Centrifugal Chiller HC-F-GFG-SSC Series (Super High Efficiency Type) HC-F-GXG-S

More information

UNIT 4: REFRIGERATION PRINCIPLE

UNIT 4: REFRIGERATION PRINCIPLE UNIT 4: REFRIGERATION PRINCIPLE 4.1 Introduction i. Buildings are essentially enclosed spaces designed for the purpose of accommodating occupants and their activities. ii. Thermal comfort is incorporated

More information

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools Dehumidification and ventilation for residential, industrial radiant systems and swimming pools HiDew is proud to present a complete range of dehumidifiers for radiant cooling systems and high performance

More information

Design & Fabrication of Hybrid Cooler

Design & Fabrication of Hybrid Cooler IJIRST International Journal for Innovative Research in Science & Technology Volume 2 Issue 11 April 2016 ISSN (online): 2349-6010 Design & Fabrication of Hybrid Cooler Shashank Chauragade Mukul Kshirsagar

More information

30GT FLOTRONIC AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS 30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed

More information

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad- 500 043 B.Tech (III II SEM) MECHANICAL ENGINEERING REFRIGERATION AND AIR CONDITIONING Prepared by, Dr. CH V K N S N Moorthy, Professor

More information

Mechanical Systems Mechanical Systems

Mechanical Systems Mechanical Systems VING IMPRO ALLY NATUR Mechanical Systems 2017 Mechanical Systems E RMANC PERFO Content Rack Units Racks Units Opti OL Indoor Mini Compact OLtec EVO Maxi Compact Flexi Optivell Innovell Econvell Maxivell

More information

Certification Programs, Standards,

Certification Programs, Standards, Certification Programs, Standards, and Guidelines Visit the AHRI Directory www.ahridirectory.org View and download AHRI Standards and Guidelines www.ahrinet.org Certification Programs, Standards, and

More information

Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ. Air cooled chiller

Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ. Air cooled chiller Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ Air cooled chiller Why choose Daikin? Daikin were the among first to pioneer the use of inverters in air cooled screw chillers. And today,

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

MECCI Engineers. Institute of Engineering Design & Research

MECCI Engineers. Institute of Engineering Design & Research MECCI Engineers Institute of Engineering Design & Research (An ISO 9001:2015 DAC International Certification for EPC Consulting, Engineering Project & Training Company) HVAC Design Course Content For Regular

More information

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost LL Chillers and Outdoor Mechanical Rooms Air-Cooled Features: Air-cooled condenser chillers with capacities from 35-345 tons Evaporative-cooled condenser chillers with capacities from 35-540 tons Variable

More information

INSTITUTE FOR ENVIRONMENTAL RESEARCH & SUSTAINABLE DEVELOPMENT NATIONAL OBSERVATORY OF ATHENS (NOA)

INSTITUTE FOR ENVIRONMENTAL RESEARCH & SUSTAINABLE DEVELOPMENT NATIONAL OBSERVATORY OF ATHENS (NOA) 1 SOLAR COOLING An Overview of European Applications & Design Guidelines Costas Balaras, Ph.D. Member ASHRAE, Mechanical Engineer, Research Director GRoup Energy Conservation (GR.E.C.) INSTITUTE FOR ENVIRONMENTAL

More information

Summary Comparison of Simulation Program Features

Summary Comparison of Simulation Program Features Summary Comparison of Simulation Program Features FEATURE DOE2.2 equest TRACE 700 HAP Public/Proprietary Public Domain Proprietary Proprietary Proprietary Simulation Method 8760 hours 8760 hours 8760 hours

More information

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto Kawasaki centrifugal chiller using water as a refrigerant Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto Contents 1. Introduction of MiZTURBO 2. Study of CO 2 emissions

More information

commercial refrigeration products

commercial refrigeration products commercial refrigeration products Evaporators Condensing Units Condensers Air Handlers Fluid Coolers Coils NOTHING BEATS A BALLY Evaporators EC MOTORS Available Half Round Low velocity Two-way low profile

More information

Inverter Ducted Split Air Source Heat Pump System with Inverter Drive Technology

Inverter Ducted Split Air Source Heat Pump System with Inverter Drive Technology Inverter Ducted Split Air Source Heat Pump System with Inverter Drive Technology The robust Bosch Inverter Ducted Split air-source heat pump system utilizes just the right amount of energy to achieve ultimate

More information

PKTEWC. Electric Wine Cooler. Wine Chilling Refrigerator MODEL:

PKTEWC. Electric Wine Cooler. Wine Chilling Refrigerator MODEL: by PKTEWC Electric Wine Cooler Wine Chilling Refrigerator MODEL: PKTEWC0 PKTEWC0 PKTEWC1 PKTEWC10 PKTEWC1 PKTEWC10 PKTEWCDS10 PKTEWCDS10 PKTECC0 Bottle Capacity Bottle Capacity 1 Bottle Capacity 1 Bottle

More information

APS Chiller Seminar. Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017

APS Chiller Seminar. Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017 APS Chiller Seminar Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017 Agenda for today Refrigeration Cycle Chiller Types and Refrigerants Compressor Styles Chilled Water Pumping Systems

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

Electric Wine Cooler. Wine Chilling Refrigerator MODEL:

Electric Wine Cooler. Wine Chilling Refrigerator MODEL: by Electric Wine Cooler Wine Chilling Refrigerator MODEL: PKTEWC08 PKTEWC80 PKTEWC12 PKTEWC120 PKTEWC18 PKTEWC180 PKTEWCDS1802 PKTEWCDS1805 PKTECC40 8 Bottle Capacity 8 Bottle Capacity 12 Bottle Capacity

More information

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a CHAPTER 9 REFRIGERATION & AIR-CONDITIONING YEAR 2012 ONE MARK Common Data For Q. 1 and Q.2 A refrigerator operates between 120 kpa and 800 kpa in an ideal vapour compression cycle with R-134a as the refrigerant.

More information

INSERT NEW PHOTO HERE

INSERT NEW PHOTO HERE INSERT NEW PHOTO HERE Photo by Chuck Berray Photo by: Cassandra Cerny, GVEA Alaska Energy Authority Absorption Chilling 101 Devany Plentovich 11/2017 2 Learning Objectives Understand: the basic operation

More information

PS & GPS SERIES PARALLEL RACK REFRIGERATION SYSTEMS

PS & GPS SERIES PARALLEL RACK REFRIGERATION SYSTEMS PS & GPS SERIES PARALLEL RACK REFRIGERATION SYSTEMS PS Series Parallel Racks For those who want to maximize energy savings and have full control of an entire refrigeration network within a facility, PS

More information

PLEXUS. Marine HVAC Components for Boats and Yachts CATALOGUE

PLEXUS. Marine HVAC Components for Boats and Yachts CATALOGUE PLEXUS Marine HVAC Components for Boats and Yachts CATALOGUE 08/2017 1 PLEXUS CATALOGUE 08/2017 Self Contained ASC MAP Series...2 Split ASP System ASP Series... 4 Water Chiller AWC Series - Single Chiller...

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

Precise Temperature Control; Compact Footprint

Precise Temperature Control; Compact Footprint Precise Temperature Control; Compact Footprint The Conair EP1 Series Portable Chillers are designed for 1 to 3 ton applications. Available as air-cooled or water-cooled, with pump sizes from 1/4 to 3 Hp

More information

CHAPTER 1 INTRODUCTION

CHAPTER 1 INTRODUCTION 1 CHAPTER 1 INTRODUCTION 1.1 Background The science which deals with creating a controlled climate in indoor space is called air conditioning. Earlier days the air-conditioning was treated as a luxury,

More information

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation

More information

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 7, Issue 11, May 2018

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 7, Issue 11, May 2018 Absorption chiller with cooling and heating for energy saving and environment friendly Yongjian Gu, Ph.D., P.E. Department of Marine Engineering United States Merchant Marine Academy 300 Steamboat Rd,

More information

Capacity: 1.5 to 6.0 Ton

Capacity: 1.5 to 6.0 Ton VACPB1 Series Wall Mount Explosion Proof Air Conditioner and Room Pressurization System Hazardous Location N.E.C. and I.E.C. Approved 50 Hertz Models 60 Hertz, High Ambient, & Custom Designs Available

More information

THE CHEAPEST WAY TO HEAT YOUR WATER

THE CHEAPEST WAY TO HEAT YOUR WATER THE CHEAPEST WAY TO HEAT YOUR WATER 2 YOU LL GET IN HOT WATER, BUT NOT WITH YOUR POWER COMPANY INSTALLING EXCEED CAN SAVE YOU UP TO 66% ON YOUR HOT WATER HEATING * With Exceed s innovative Heat Pump Water

More information

APPLICABILITY OF VRV/VRF HVAC SYSTEM A JUDICIOUS AND RATIONAL APPROACH

APPLICABILITY OF VRV/VRF HVAC SYSTEM A JUDICIOUS AND RATIONAL APPROACH APPLICABILITY OF VRV/VRF HVAC SYSTEM A JUDICIOUS AND RATIONAL APPROACH KULDIP PESHIN CHIEF ENGINEER CENTRAL PUBLIC WORKS DEPARTMENT CHENNAI 600090 ABSTRACT Use of Variable Refrigerant Volume (VRV)/Variable

More information

Inverter Swimming Pool Heat Pump

Inverter Swimming Pool Heat Pump P Inverter Swimming Pool Heat Pump Content I. Application... 2 II. Features... 2 III. Technical Parameter... 3 IV. Dimension... 4 V. Installation instruction... 5 VI. Operation instruction... 9 VII. Testing...

More information