Accomplish Maximum Green Results in Commercial Buildings #

Size: px
Start display at page:

Download "Accomplish Maximum Green Results in Commercial Buildings #"

Transcription

1 Accomplish Maximum Green Results in Commercial Buildings # Nearly everyone agrees that multiple small boiler systems provide optimum efficiency when compared to a single larger boiler system in commercial buildings. These savings are often enhanced by pumping systems that vary system flow to meet load demand. For maximum energy saving results primary/secondary pumping is the right choice, as explained below: 1) To achieve optimal energy savings, lowest seasonal energy consumption and most precise load tracking primary/secondary pumping should be selected in lieu of primary loop systems only. With primary/secondary pumping the boilers not operating to meet the immediate load will not be consuming or losing energy. Because the system load is rarely at maximum, one or more boilers will be in standby mode most of the time. 2) Standby flue and jacket losses occur anytime a boiler has heated water flowing through it, as is normally the case in primary loop systems. This is true for all types of boilers. Heat losses are virtually eliminated in standby boilers utilizing primary/secondary pumping. A significant additional savings is in electrical operating energy. Standby boilers not only save heat energy losses, they consume minimal electrical power. This is not the case with primary loop systems that typically pump water continuously through all boilers. 3) Most boiler manufacturers that promote primary loop pumping have boilers that contain relatively high water volumes. The only way to stop these continuous standby and electrical loss is to change to a primary/secondary system, or stay with the total primary loop design and isolate each boiler. Then it can be shut off when not needed. Isolation, if accomplished, is done by adding costly, (spring loaded) often problematic, automatic water valves for every boiler. These typically cost $5,000 or more per boiler. Primary/secondary boilers are self-isolating, so this additional first cost and ongoing maintenance cost is completely eliminated. 4) On the rare occasion when primary loop systems boilers are isolated as described above, the stored Btus contained in the water will still be lost on every off cycle. The stored water content of high mass low recovery boilers is in the order of 30 to 40 times that of low mass high recovery boilers. The heat contained in the stored water is typically 500 Btus per gallon. A one million Btu low mass boiler may contain only one gallon where as a high mass boiler may hold 30 or more gallons. Thus the low mass boiler will contain only 500 Btu s and the high mass will contain 15,000 (30 x 500 = 15,000) which is lost each time it goes into standby. 5) With both primary/secondary and full primary loop pumping, the system pump runs any time there is a building demand, often 24/7 during the heating

2 season. For primary/secondary systems, the system pump is sized for the system loop only. One does not need to upsize that pump for the pressure drop in the boilers and boiler piping. That is handled by the individual boiler pumps. The primary system pump will be the only one running continuously. The secondary pumps run only when their specific boiler is called on to fire. This reduces total first cost as well as operating cost. 6) When a full primary loop design is selected, the system pump will always be providing flow through all the boilers, including those on standby. This allows a manufacturer to specify extremely low and impractical flow turndown if they wish, even to the point of Zero flow capability. This is not really possible or recommended for use in any legitimate manufacturer s instructions, including those who get it specified. It should be pointed out that equal or greater turn down can be achieved by utilizing primary/secondary systems. The variable volume system pump can operate at the lower flow rates associated with only the boilers currently on line. As an example, two Raypak XTherms are capabable of 24:1 flow turndown, or 36 with 3, 48 with 4, etc. Who needs more? 7) Because each boiler is pumped separately, with primary/secondary pumping, boilers in standby mode can be isolated from the system for routine maintenance, service or repair without interrupting the operation of the rest of the heating system 8) To further illustrate the various savings attributable to primary/secondary pumping systems, an actual specified design that was recently converted from primary loop to primary/secondary is summarized below. The potential savings in both first cost and continued operation of the primary/secondary design were recognized. The savings calculation was based on lower hardware cost and bonus future energy savings, without even considering the savings from eliminating isolation valves. They weren t specified on this job. First and operating savings justified any piping drawing alterations needed, and the system selection became the optimum --- Primany/Secondary Pumping with Raypak High Recovery Boilers. Example: The initial design specified two high mass boilers plumbed in parallel. The specified primary only system pump was 5 horsepower. Each boiler was to be fitted with costly automatic isolation valves that, along with the boilers, added to the total system pressure drop. Even with the isolation valves the stored energy

3 in the heated water in the boiler is lost each time the boiler is shut down and isolated.. By going to low mass high recover copper finned tube boilers with primary/secondary pumping the system pump no longer needed to pump through the boilers and isolation valves. This resulted in a reduction for required system pump to 3 horsepower. Each of the two high recovery boilers incorporated a ½ horsepower boiler pump and a 1/8 horsepower variable speed injector pump. The injector pump typically runs at a reduced speed and using less than 1/8 th horsepower. The ½ plus 1/8 horsepower pumps add up to 5/8 horsepower capacity per boiler. The revised design pumping requirements then become 3 horsepower for the system and 2 sets of pumps at 5/8 horsepower per set for a combined total of 3 + (2 X 5/8) = 4 1/4 horsepower versus 5 for the original design. So even at peak load the pumping horsepower is reduced from 5 to 4 ¼. Keep in mind that for most of the season only one boiler will be required with the associated pumping capacity of 3 + 5/8 = 3 5/8 verses 5 with the original design. Additionally high recovery low mass vertical boilers substituted are certified for 94% or more thermal efficiency versus 92% for the originally specified high mass boilers. The revised design significantly reduced first cost from the original projections. Continuing operational energy savings will accrue each year in electrical energy from reduced pump horsepower. There is also, along with the electrical savings, less heat energy loss from stored water each time a boiler shuts down and is isolated from the system. The higher thermal efficiency of the copper finned tube boilers is a green bonus. This is just one real world example. Larger systems with more boilers will demonstrate even greater savings. The two drawings on the following attachment show the original piping and pumping design and the revised primary/secondary pumping design.

4

5 Return to Bulletin

Systems and Tanks. 40 H/V 60 H/V 80 V 115 V 139 V Gallon. Applications Sizing System Design

Systems and Tanks. 40 H/V 60 H/V 80 V 115 V 139 V Gallon. Applications Sizing System Design Systems and Tanks Model size 0 H/V 60 H/V 80 V 5 V 9 V Gallon Applications Sizing System Design Systems In recent years there have been many energy-saving improvements to controls and hydraulics associated

More information

Medium Mass Boilers. Maxim Power VT

Medium Mass Boilers. Maxim Power VT Medium Mass Boilers Maxim Power VT What is a Medium Mass Boiler? Sufficient Mass (Boiler water capacity) to act as a built in buffer tank. Sufficient Mass to handle varying system design flows without

More information

MAXIMIZING HYDRONIC SYSTEM DESIGN PART III

MAXIMIZING HYDRONIC SYSTEM DESIGN PART III MAXIMIZING HYDRONIC SYSTEM DESIGN PART III Presented by Cleaver Brooks Steve Connor & DCEs David Grassl June 21, 2017 TODAY S TOPICS Dispelling common myths about condensing boilers Supply water temperature

More information

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32 Models 1005, 1505, 2005 Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32 Xtreme Performance Up to 99% thermal efficiency! Think Green Think Raypak Raypak s Next Generation Condensing

More information

Boilers Variable Fire Boilers

Boilers Variable Fire Boilers VF Boilers Variable Fire Boilers Advanced EMC-5000 Modulating Control The EMC-5000 Modulating Control provides true self-diagnostic capabilities to eliminate guesswork in troubleshooting. It is the most

More information

hydronics WHAT S WRONG WITH THIS SCHEMATIC?

hydronics WHAT S WRONG WITH THIS SCHEMATIC? BY JOHN SIEGENTHALER WHAT S WRONG WITH THIS SCHEMATIC? In the September/October 2005 issue of HPAC Magazine, methods to draw hydronic piping schematics were discussed. These drawings are an efficient way

More information

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

Models 1005, 1505, 2005 Up to 99% thermal efficiency! Models 1005, 1505, 2005 Up to 99% thermal efficiency! Can be vented with PVC pipe - D32 Option or Centrotherm Polypropylene (D-33) Proudly made in the U.S.A Xtreme Performance Up to 99% thermal efficiency!

More information

Best Practices for Condensing Boilers

Best Practices for Condensing Boilers ASHRAE www.ashrae.org. Used with permission from ASHRAE Journal at www.cleaverbrooks.com. This article may not be copied nor distributed in either paper or digital form without ASHRAE s permission. For

More information

Versa- Hydro. up to 96% Efficient

Versa- Hydro. up to 96% Efficient Versa- Advanced Heating & Hot Water Systems Hydro up to 96% Efficient The cost effective Versa-Hydro combines space heating, domestic hot water, and total system control into one compact, high efficiency

More information

Radiant Heating. Systems

Radiant Heating. Systems O p t i m i z i n g t h e P e r f o r m a n c e o f Radiant Heating Systems Minimizing costly mistakes and maximizing a radiant project s performance by focusing on building and system efficiency Radiant

More information

Ohio Energy. Workshop HH. Strategies & Technologies to Improve the Boiler Room Efficiency. Wednesday, February 21, p.m. to 3:15 p.m.

Ohio Energy. Workshop HH. Strategies & Technologies to Improve the Boiler Room Efficiency. Wednesday, February 21, p.m. to 3:15 p.m. Ohio Energy Workshop HH Strategies & Technologies to Improve the Boiler Room Efficiency Wednesday, February 21, 2018 2 p.m. to 3:15 p.m. Biographical Information Jon Green, Mechanical Equip. Consultant

More information

Get The Edge Over The Competition with The Summit

Get The Edge Over The Competition with The Summit Gas-Fired Hydronic Boilers Condensing and Modulating for Low NOx and High Efficiency Get The Edge Over The Competition with The Summit Solve installation problems and significantly reduce running costs

More information

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger. ONICON Insertion Turbine Flow Meters Provide an accurate, cost effective option for flow measurement of relatively clean liquids such as those found in closed loop HVAC systems. Each meter is built to

More information

COLD WATER START A P P L I C AT I O N S

COLD WATER START A P P L I C AT I O N S COLD WATER START It is commonly known that prolonged internal condensation will dramatically shorten the life of standard efficiency boilers. While Raypak boilers can operate without harmful condensation

More information

Using ECM Smart Circulator Pumps in Primary Pump Applications in Hydronic Systems

Using ECM Smart Circulator Pumps in Primary Pump Applications in Hydronic Systems Monday, November 27, 2017 Using ECM Smart Circulator Pumps in Primary Pump Applications in Hydronic Systems Monday Morning Minutes by Norm Hall, November 27, 2017 Last week I featured the ECM High-Efficiency

More information

Models 1005A, 1505A, 2005A 2505, 3005, 3505, Touch Screen VERSA IC. Control Platform. Up to 99% thermal efficiency! ULTRA HIGH EFFICIENCY

Models 1005A, 1505A, 2005A 2505, 3005, 3505, Touch Screen VERSA IC. Control Platform. Up to 99% thermal efficiency! ULTRA HIGH EFFICIENCY ULTRA HIGH EFFICIENCY Touch Screen VERSA IC Control Platform Models 1005A, 1505A, 2005A 2505, 3005, 3505, 4005 Up to 99% thermal efficiency! Proudly assembled in the U.S.A. Xtreme Performance Up to 99%

More information

Ve r s a - Hyd ro. 96% Efficient. The cost effec t i ve. ersa-hydro

Ve r s a - Hyd ro. 96% Efficient. The cost effec t i ve. ersa-hydro ersa-hydro Versa- Hydro 96% Efficient The cost effec t i ve Ve r s a - Hyd ro combines space heating, domestic hot water, and total system control into one compact, high efficiency mod-con unit. I n n

More information

Intro to Commercial Tankless Technology

Intro to Commercial Tankless Technology Rinnai America Corporation 103 International Drive Peachtree City, GA 30269 Telephone: (678) 829-1700 Fax: (678) 364-8643 Toll Free:(800) 621-9419 Email: marketing@rinnai.us Web: www.rinnai.us Intro to

More information

Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014

Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014 Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014 Today, hydronic boilers are producing greater efficiencies than previously thought possible, all due

More information

TRACE 700. Slide 1. Hello, my name is Nick Cavitt and I m a marketing engineer in the C.D.S. group at TRANE.

TRACE 700. Slide 1. Hello, my name is Nick Cavitt and I m a marketing engineer in the C.D.S. group at TRANE. Slide 1 TRACE 700 Chiller Sequencing and Controls Hello, my name is Nick Cavitt and I m a marketing engineer in the C.D.S. group at TRANE. Today, we will be talking about the Plant Sequencing and Controls

More information

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS David Grassl PE Mechanical Engineer Principal Boilers are closed pressure vessels that are used to heat fluids -- either water or steam. They

More information

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS David Grassl PE Mechanical Engineer Principal Similar to traditional boiler systems, condensing boiler systems have many designs they can operate

More information

ULTRA HIGH EFFICIENCY. Platform with Touch Screen VERSA IC. Up to 99% thermal efficiency! Proudly assembled in the U.S.A.

ULTRA HIGH EFFICIENCY. Platform with Touch Screen VERSA IC. Up to 99% thermal efficiency! Proudly assembled in the U.S.A. ULTRA HIGH EFFICIENCY VERSA IC Platform with Touch Screen Models 1005A, 1505A, 2005A 2505, 3005, 3505, 4005 Up to 99% thermal efficiency! Proudly assembled in the U.S.A. Xtreme Performance Up to 99% thermal

More information

Trim Pump Impellers. Fredrick/Weinman Engineered Products 2-1/2 KH, 2-1/2 x 3 x 12

Trim Pump Impellers. Fredrick/Weinman Engineered Products 2-1/2 KH, 2-1/2 x 3 x 12 Head, ft. w.c. Trim Pump Impellers TRIM THE PUMP IMPELLER SO THE FLOW PRODUCED MATCHES THE DESIGN REQUIREMENT WITH THE DISCHARGE SERVICE VALVE WIDE OPEN. IN MOST CASES, THIS WILL REDUCED THE PUMP ENERGY

More information

clearfire Large capacity condensing boilers 4,000 to 12,000 MBTU/hr

clearfire Large capacity condensing boilers 4,000 to 12,000 MBTU/hr LC clearfire Large capacity condensing boilers 4,000 to 12,000 MBTU/hr Total Integration in a small footprint with unprecedented power for hydronic applications Cleaver-Brooks has raised the bar and changed

More information

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content New Versa IC TM Control Platform up to 99% Efficiency! Can be vented with: PVC, Centrotherm Polypropylene or Stainless Steel. MBTU s 300A 400A 500A 700A 850A CSA Certified Low Lead Content Less Than.25%

More information

B-40/B-41 Modulating Temperature Controller

B-40/B-41 Modulating Temperature Controller INSTALLATION & OPERATING INSTRUCTIONS B-40/B-41 Modulating Temperature Controller For Raytherm Boilers & Water Heaters H2 514-4001 WH2 2100-4001 Catalog No. 5000.70 Effective: 12-21-11 Replaces: NEW P/N

More information

GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS

GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS Copyright 2011. R. Trethewey, All rights reserved. No part of this document or file may be used without permission of the author. All diagrams are conceptual

More information

TANKLESS WATER HEATER HEATING SOLUTIONS

TANKLESS WATER HEATER HEATING SOLUTIONS TANKLESS WATER HEATER HEATING SOLUTIONS 2017 Rinnai America Corporation. The material contained in this course was researched, assembled, and produced by Rinnai America Corporation and remains their property.

More information

Presented by Steve Connor August 26, Boiler Choices: The What, When & Why

Presented by Steve Connor August 26, Boiler Choices: The What, When & Why Presented by Steve Connor August 26, 2015 Boiler Choices: The What, When & Why What We Are Covering Today Commercial/industrial market applications. Steam & hot water boiler types. Application decision

More information

An Introduction to True Modular Boiler Systems

An Introduction to True Modular Boiler Systems An Introduction to True Modular Boiler Systems By Floyd A. Burkel Jr., P.E. TABLE OF CONTENTS I. Introduction... 3 II. Types of Boilers... 4 III. Stages of a Boiler operation... 8 IV. Oversizing... 12

More information

CONDEXA PRO EXCELLENCE AND VERSATILITY

CONDEXA PRO EXCELLENCE AND VERSATILITY CONDEXA PRO EXCELLENCE AND VERSATILITY CONDEXA PRO Riello Condexa PRO is a condensing pre-mixed, fan-induced, 10:1 modulating wall hung boiler. Designed both for stand-alone and cascade applications up

More information

C1050ES Tankless Water Heater

C1050ES Tankless Water Heater Engineering Submittal Sheet Dimensions and Connections B C D C Combustion air inlet Exhaust outlet Optional combustion air inlet Top view Top view A E F Hot water outlet Cold water inlet Inlet water filter

More information

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters Energy Efficiency Through Waste Heat Recovery Heat Recovery Centrifugal Chillers and Templifier Water Heaters Innovative Solutions for Saving Energy McQuay offers two innovative methods of saving energy

More information

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available. PART 1: GENERAL 1.01 General Requirements A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the

More information

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost LL Chillers and Outdoor Mechanical Rooms Air-Cooled Features: Air-cooled condenser chillers with capacities from 35-345 tons Evaporative-cooled condenser chillers with capacities from 35-540 tons Variable

More information

SAMPLE. added benefit of reduced operating costs during low demand periods, such as spring and fall.

SAMPLE. added benefit of reduced operating costs during low demand periods, such as spring and fall. Chapter 4 Variable-speed pumps. A variable-speed pump varies the flow rate by maintaining a constant pressure differential as zone valves open and close. A sensor measures the difference in pressure between

More information

TOTAL SYSTEM EFFICIENCY: CONDENSING BOILER SYSTEM MYTH BUSTING. David Grassl PE Mechanical Engineer Principal

TOTAL SYSTEM EFFICIENCY: CONDENSING BOILER SYSTEM MYTH BUSTING. David Grassl PE Mechanical Engineer Principal TOTAL SYSTEM EFFICIENCY: CONDENSING BOILER SYSTEM MYTH BUSTING David Grassl PE Mechanical Engineer Principal There are many reasons why engineers have been led to believe that condensing boilers do not

More information

Efficient Steam System Design

Efficient Steam System Design Efficient Steam System Design The word Efficient is often used to describe the general performance of a system. However it is important to distinguish between efficiency and effectiveness. Efficiency is

More information

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer without Boiler Replacement TRUE GREEN SOLUTIONS NEW Patent Pending EcoFlex + System Modulating Fan-Powered Economizer EcoFlex + System Because They Are Your Btus EcoFlex + System - a packaged modulating

More information

RTC. Stainless Steel Condensing Floor Standing Boilers Technical data sheet. High efficiency commercial heating

RTC. Stainless Steel Condensing Floor Standing Boilers Technical data sheet. High efficiency commercial heating cod. Doc-0079191 rev. 3 12/2017 High efficiency commercial heating RTC Stainless Steel Condensing Floor Standing Boilers Technical data sheet High water content 3-pass stainless steel (316Ti) condensing

More information

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED High Efficiency Condensing Boilers Proven Reliability, American-Made Home Heating Comfort. Look for this logo throughout this literature to see the unique features that set U.S. Boiler Company apart from

More information

Commercial Hot Water Maker

Commercial Hot Water Maker Boiler Mate Series Commercial Hot Water Maker Indirect-Fired Water Heaters Models WH-7C and WH-10C 1 INNOVATIVE DESIGN FOR REAL WORLD APPLICATIONS The Boiler Mate Series commercial Hot Water Maker design

More information

AM Rapid Recovery Water Heaters

AM Rapid Recovery Water Heaters Technical Data Sheet AM Rapid Recovery Water Heaters The Advanced Modular Rapid Recovery water heaters from AERCO provide a complete water heating solution in one convenient package. With a packaged integrated

More information

Models 504 thru 2004 Category I with vertical vent. Models 503 thru 2003 Category IV Venting. CSA Certified Lead Content Less Than.

Models 504 thru 2004 Category I with vertical vent. Models 503 thru 2003 Category IV Venting. CSA Certified Lead Content Less Than. s 504 thru 2004 Category I with vertical vent s 503 thru 2003 Category IV Venting Up to 88.4% thermal efficiency! CSA Certified Lead Content Less Than.25 Pb Category I*-up to 85% efficiency Category IV-up

More information

investment in R&D, the commitment to - name.

investment in R&D, the commitment to - name. The Hillphoenix name is synonymous with innovative, sustainable and extremely efficient refrigeration systems in a variety of business segments. While much of the company s reputation has been built as

More information

940ES Tankless Water Heater

940ES Tankless Water Heater Engineering Submittal Sheet Dimensions and Connections B C D C Combustion air inlet Exhaust outlet Optional combustion air inlet Top view Top view A Hot water outlet Cold water inlet E F Front view Side

More information

P-K MACH 'n' ROLL DOMESTIC HOT WATER AND COMFORT HEAT SYSTEM

P-K MACH 'n' ROLL DOMESTIC HOT WATER AND COMFORT HEAT SYSTEM P-K MACH 'n' ROLL DOMESTIC HOT WATER AND COMFORT HEAT SYSTEM Harsco Industrial Patterson-Kelley continues to create innovative solutions that change the expectations of what a domestic hot water system

More information

The Book of AERMEC NRL Sequence of Operation

The Book of AERMEC NRL Sequence of Operation The Book of AERMEC NRL Sequence of Operation Heating and cooling operation. 2 Sequence of operation Aermec air to water chiller/heat pump use Hydronic s in conjunction with refrigerant to provide heating

More information

Authority - City Engineer Effective August 2, 2011 Amended November 1, 2011, November 1, 2012 and December 11, 2013

Authority - City Engineer Effective August 2, 2011 Amended November 1, 2011, November 1, 2012 and December 11, 2013 City of Vancouver Planning - By-law Administration Bulletins Planning and Development Services, 453 W. 12th Ave Vancouver, BC V5Y 1V4 F 604.873.7000 fax 604.873.7060 planning@vancouver.ca NEIGHBOURHOOD

More information

Now Available with PVC & Polypropylene Vent Configurations

Now Available with PVC & Polypropylene Vent Configurations FFC-3R Now Available with PVC & Polypropylene Vent Configurations Fully Condensing Ultra Efficient The gas-fired Futera Fusion brings the field-proven performance of Futera Series boilers and water heaters

More information

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS Comprehensive technology, energy-saving performance, plus compact professional design make HydroShark s modular panel

More information

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH CE CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH Energy Savings and Environmental Benefits Due to its highly effective heating surface area and true counter-flow heat exchanger arrangement,

More information

940ES Tankless Water Heater

940ES Tankless Water Heater Engineering Submittal Sheet Overview and Certifications LOW-LEAD U P C C US Massachusetts Plumbing Board Approved Engineering Specifications Water heater shall be a Model Therm 940 ES. Plant shall consist

More information

High Efficiency Commercial Gas Water Heaters

High Efficiency Commercial Gas Water Heaters High Efficiency Commercial Gas Water Heaters 97% Thermal Efficiency LonWorks Compatible Intelligence Highly Flexible and Ultra Quiet Super Compact Design Variable Frequency Drive Lets You Change Output

More information

Multiple Heater Controller TempTracker Mod+, up to 16 heaters

Multiple Heater Controller TempTracker Mod+, up to 16 heaters WHP HEAT EXCHANGER JACKET OTHER GAS TRAIN SAFETIES OPERATING CONTROLS ASME, National Board Registered, 160 PSI HLW Stamp Heat Exchanger Tubes Cupro Nickel Bronze Headers Stainless Steel Condensing Heat

More information

Raypak Residential Products

Raypak Residential Products Raypak Residential Products Raypak s Residential Boiler Product Family Raypak revolutionized the boiler market in 1948 with the first innovative high recovery boilers that utilized superior finned copper

More information

Boiler Start-Up Cycle

Boiler Start-Up Cycle COLD WATER START It is commonly known that prolonged internal condensation will dramatically shorten the life of standard boilers and water heaters. While Raypak boilers and water heaters can operate without

More information

IMPROVING EFFICIENCY AND QUALITY USING A PERMANENT ORIFICE STEAM TRAPPING SYSTEM

IMPROVING EFFICIENCY AND QUALITY USING A PERMANENT ORIFICE STEAM TRAPPING SYSTEM IMPROVING EFFICIENCY AND QUALITY USING A PERMANENT ORIFICE STEAM TRAPPING SYSTEM Dave Walker Patti Lowe Matrix Northwest Portland, Oregon Introduction Thank you for being here to find out about permanent

More information

C1210ES Tankless Water Heater

C1210ES Tankless Water Heater Engineering Submittal Sheet Dimensions and Connections B C D C Combustion air inlet Exhaust outlet Optional combustion air inlet Top view Top view A E Hot water outlet Cold water inlet F H J C I K G Front

More information

ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International Presentation Overview Water Heater Piping Strategies How to size a water heater?

More information

New VERSA IC. Platform. Up to 99% thermal efficiency! Proudly made in the U.S.A

New VERSA IC. Platform. Up to 99% thermal efficiency! Proudly made in the U.S.A New VERSA IC Control Platform Models 1005A, 1505A, 2005A Up to 99% thermal efficiency! Can be vented with PVC pipe - D32 Option or Centrotherm Polypropylene (D-33) Proudly made in the U.S.A Xtreme Performance

More information

This presentation is posted for public use. ACEEE does not endorse any product or service.

This presentation is posted for public use. ACEEE does not endorse any product or service. This presentation is posted for public use. ACEEE does not endorse any product or service. ACEEE accepts no responsibility for any facts or claims this presentation may contain. Where is Hot Water in High

More information

IPS. The Affordable Green HVAC Solution! Ideal for select service hospitality, assisted living, condos, apartments and dorms.

IPS. The Affordable Green HVAC Solution! Ideal for select service hospitality, assisted living, condos, apartments and dorms. The Affordable Green HVAC Solution! IPS I N T E G R A T E D P I P I N G S Y S T E M Ideal for select service hospitality, assisted living, condos, apartments and dorms. Sensible Design. Remarkable Efficiency.

More information

KE2 EvaporatorEfficiency Theory of Operation

KE2 EvaporatorEfficiency Theory of Operation Theory T.1.1 June 011 TM thermsolutions ENTER BACK KE Therm Solutions, Advanced Energy Saving Technology for Commercial Refrigeration and AC Systems Page Table of Contents Basic Refrigeration System Evaporator

More information

Adsorption Chillers Energysmart Green Cooling

Adsorption Chillers Energysmart Green Cooling Adsorption Chillers Energysmart Green Cooling New Partners in innovation Leaders in Dehumidification... Worldwide Power Partner Inc USA www.bryair.com Recover Low Grade Process Waste Heat For Energy Smart

More information

Allcan TM Installation Manual

Allcan TM Installation Manual Allcan TM Installation Manual NOTICE: READ THESE INSTRUCTIONS CAREFULLY. FAILURE TO FOLLOW INSTRUCTIONS VOIDS WARRANTY. Introduction: The PHP Allcan (USA patent pending) is a complete primary/secondary

More information

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU Unmatched Efficiency and Low-NOx Technology in a Condensing Boiler The ClearFire -C is a completely

More information

The world s standard in efficiency. CBEX FIRETUBE

The world s standard in efficiency. CBEX FIRETUBE The world s standard in efficiency. CBEX FIRETUBE CBEX Firetube Boilers For decades, engineers have been trying to build a better and more efficient boiler system, but it took Cleaver-Brooks to challenge

More information

The PurePro. Family of Indirect Water Heaters. A smart choice for abundant, rapid hot water heating. pureproproducts.com

The PurePro. Family of Indirect Water Heaters. A smart choice for abundant, rapid hot water heating. pureproproducts.com The PurePro Family of Indirect Water Heaters A smart choice for abundant, rapid hot water heating pureproproducts.com PurePro Indirect Water Heaters: The best option for home hot water needs As overall

More information

Stainless Steel Unvented Cylinders

Stainless Steel Unvented Cylinders Stainless Steel Unvented Cylinders 1992 Tornado 1 1996 Tornado Elite 1999 Tornado 2 2002 Tornado and Tempest Stainless Steel Modern Day Requirements More people are finding that today s requirements for

More information

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead.

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead. VERSA IC Control Platform up to99% Efficiency! Can be vented with: PVC, Centrotherm Polypropylene or Stainless Steel. MBTU s 300A 400A 500A 700A 850A CSA Certified Low Lead Content Less Than.25% Lead Ultra

More information

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT MODBUS AND BACnet MSTP PROTOCOL CASCADING SEQUENCER WITH CASCADE REDUNDANCY 6 INPUTS FROM 750,000 TO 2.0 MILLION BTU/HR UP TO 25:1 TURNDOWN RATIO

More information

HTP s history of developing new and innovative products has allowed the company to grow over 18 % annually for the last 10 years.

HTP s history of developing new and innovative products has allowed the company to grow over 18 % annually for the last 10 years. G R E E N T E C H N O L O G I E S H I G H E F F I C I E N C Y, R E N E W A B L E E N E R G Y A N D L O W E M I S S I O N S TWO GENERATIONS OF GROWTH & INNOVATION Revenue Growth Established 1974 by Mr.

More information

Airblast Tech Tips Grit Recycling Systems - common questions and answers

Airblast Tech Tips Grit Recycling Systems - common questions and answers What type should I buy? The type of system that you will require depends on the method you like to use or feel will give you the lowest costs for completing the work you want to bid on. Just as every job

More information

- Data Brochure Universal Reset Module 422

- Data Brochure Universal Reset Module 422 - Data Brochure Universal Reset Module 422 D 422 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

HIGH EFFICIENCY COMMERCIAL BOILERS

HIGH EFFICIENCY COMMERCIAL BOILERS HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT MODBUS AND BACnet MSTP PROTOCOL CASCADING SEQUENCER WITH CASCADE REDUNDANCY 5 INPUTS FROM 2.5 TO 5.0 MILLION BTU/HR UP TO 20:1 TURNDOWN RATIO

More information

CONTROLLED CHILLED BEAM PUMP MODULE

CONTROLLED CHILLED BEAM PUMP MODULE ENERGY SAVINGS 1 ST COST SAVINGS PROACTIVE CONTROL CONTROLLED CHILLED BEAM PUMP MODULE Active condensation control system effectively eliminates chilled beam condensation High efficiency, variable speed

More information

RoofPak Applied Rooftop Systems

RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak applied rooftop systems the ideal solution

More information

What Size Electric Tankless Water Heater Do I

What Size Electric Tankless Water Heater Do I What Size Electric Tankless Water Heater Do I Need For My House According to the EPA, residential electric water heaters are the second highest energy users in American What size tankless water heater

More information

Boiler Start-Up Cycle SYSTEM RETURN

Boiler Start-Up Cycle SYSTEM RETURN COLD WATER START It is commonly known that prolonged internal condensation will dramatically shorten the life of standard boilers and water heaters. While Raypak boilers and water heaters can operate without

More information

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs Q: How is the WSAC a closed-loop cooling system? A: The WSAC is a closed-loop cooling system because the process loop being cooled is inside the tube bundles

More information

Summary of 60-Day Notice: Heating Efficiency

Summary of 60-Day Notice: Heating Efficiency Notification Date: November 5, 2015 Summary of 60-Day Notice: Heating Efficiency Public Service Company of Colorado ( the Company ) posts this 60-Day Notice to add a new measure to the Heating Efficiency

More information

C1210ESC Tankless Water Heater

C1210ESC Tankless Water Heater Engineering Submittal Sheet Overview and ertifications L W LOW-LEAD U P US Massachusetts Plumbing Board Approved Engineering Specifications Water heater shall be a Model Therm 1210 ES. Plant shall consist

More information

Engineering Bulletin Rev B. Contents. Piping Arrangements for Heat Pump Water Heating Systems

Engineering Bulletin Rev B. Contents. Piping Arrangements for Heat Pump Water Heating Systems Engineering Bulletin 940126-0003 Rev B Piping Arrangements for Heat Pump Water Heating Systems Contents 1. INTRODUCTION... 0 2. WATER PIPING... 0 3. HEAT PUMP WATER HEATER PIPING... 1 4. RINGMAIN (RECIRCULATING

More information

NEW. Demand-Controlled Exhaust Systems for Commercial and Industrial Bakeries. For Commercial and industrial Baking Oven Systems

NEW. Demand-Controlled Exhaust Systems for Commercial and Industrial Bakeries. For Commercial and industrial Baking Oven Systems Demand-Controlled Exhaust Systems for Commercial and Industrial Bakeries TRUE GREEN SOLUTIONS NEW For Commercial and industrial Baking Oven Systems Variable Speed and Direct Drive Natural Gas, LP Gas and

More information

ULTRA HIGH EFFICIENCY CONDENSING BOILERS MILLION BTU/HR

ULTRA HIGH EFFICIENCY CONDENSING BOILERS MILLION BTU/HR ULTRA HIGH EFFICIENCY CONDENSING BOILERS 2.5 6.0 MILLION BTU/HR UNCOMPROMISING PERFORMANCE A REVOLUTION IN FIRETUBE CONDENSING BOILER DESIGN Fulton's ENDURA+ efficiently captures up to 99% of the fuel

More information

up to 99% Efficiency! MBTU Models Can be vented with PVC CSA Verified lead Content Less Than.25% Pb Ultra Low Emissions

up to 99% Efficiency! MBTU Models Can be vented with PVC CSA Verified lead Content Less Than.25% Pb Ultra Low Emissions up to 99% Efficiency! Can be vented with PVC MBTU s 300 400 500 700 850 CSA Verified lead Content Less Than.25% Pb Ultra Low Emissions Xtreme Outdoor Performance Up to 99% part load! XFyreT Condensing

More information

NET ENERGY WATER LOOPS A clear path to net zero energy buildings

NET ENERGY WATER LOOPS A clear path to net zero energy buildings Presents NET ENERGY WATER LOOPS A clear path to net zero energy buildings Alan Niles WaterFurnace International This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer

More information

CONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS

CONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS FFC-2 CONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS The gas-fired Futera Fusion TM now brings the field-proven performance of Futera III Modulation boilers and water heaters

More information

Vitocrossal 300, CU3A - Introduction

Vitocrossal 300, CU3A - Introduction - Introduction Sales Presentation Foil 2, 04/2015 Viessmann Manufacturing Floor standing, high mass, gas-fired condensing boiler Sales Presentation Foil 3, 04/2015 Viessmann Manufacturing Features: Floor

More information

Leaseholder Energy Efficiency November 2011

Leaseholder Energy Efficiency November 2011 Leaseholder Energy Efficiency November 2011 Contents: Energy Saving Tips Insulation White Goods Heating Grant Funding Fuel Switching Chris Moorhouse KNH 1 ENERGY SAVING TIPS Turn your thermostat down.

More information

Domestic Hot Water Heaters and Boilers FTIIIC-6

Domestic Hot Water Heaters and Boilers FTIIIC-6 Domestic Hot Water Heaters and Boilers FTIIIC-6 Full Modulation, High Efficiency Hot Water Supply and Hydronic Heating Boilers The gas-fired Futera III brings the field-proven performance of Futera Series

More information

FTIIIC-10. Domestic Hot Water Heaters and Boilers

FTIIIC-10. Domestic Hot Water Heaters and Boilers FTIIIC-10 Domestic Hot Water Heaters and Boilers Full Modulation, High Efficiency Hot Water Supply and Hydronic Heating Boilers The gas-fired Futera III brings the field-proven performance of Futera Series

More information

CAMUS. two-pass counter flow fire tube commercial boilers. for hydronic heating and hot water supply TURNDOWN RATIO! HYDRONICS LTD. Rev.

CAMUS. two-pass counter flow fire tube commercial boilers. for hydronic heating and hot water supply TURNDOWN RATIO! HYDRONICS LTD. Rev. UP TO 25:1 TURNDOWN RATIO! CAMUS ADVANTUS HYDRONICS LTD. for hydronic heating and hot water supply two-pass counter flow fire tube commercial boilers Rev.03 Rev.00 FEATURES & CONTROLS get connected In

More information

Moving to the Cloud: The Potential of Hosted Central Station Services

Moving to the Cloud: The Potential of Hosted Central Station Services Moving to the Cloud: The Potential of Hosted Central Station Services Moving to the Cloud: The Potential of Hosted Central Station Services The global market for alarm monitoring services is expected to

More information

HYDRONICS BY JOHN SIEGENTHALER

HYDRONICS BY JOHN SIEGENTHALER HYDRONICS BY JOHN SIEGENTHALER ALTERNATIVES TO PRIMARY/SECONDARY PIPING Most people who have been involved with modern hydronic heating have heard of primary/secondary (P/S) piping. For many it is now

More information

Dell DR Series Appliance Cleaner Best Practices

Dell DR Series Appliance Cleaner Best Practices Dell DR Series Appliance Cleaner Best Practices Dell Engineering June 2016 A Dell Best Practices Document Revisions Date July 2016 Description Initial release THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES

More information

High Integrity Pressure Protection System

High Integrity Pressure Protection System High Integrity Pressure Protection System 412748_CCI_HIPPS.indd 1 A CCI HIPPS offering is unique in its: Innovative custom engineered system approach Variety of actuator and valve solutions for an optimized

More information

June Copyright Climatec

June Copyright Climatec June 2013 Copyright Climatec GUIDLINES FOR CENTRAL PLANT OPTIMIZATION The following document provides guidelines which if followed will maximize the energy savings potential for a central plant available

More information