EQUIPMENT CLEANING Indira Pindi Watershed Monitoring September 20, 2017
|
|
- Miles McLaughlin
- 5 years ago
- Views:
Transcription
1 EQUIPMENT CLEANING Indira Pindi Watershed Monitoring September 20, 2017
2 Overview Why cleanliness is next to godliness Cleaning materials & containers General cleaning requirements Documentation Field cleaning GW, SW, & sediment equipment Contamination
3 Why is cleaning important? To remove any remaining analytes or substances that could interfere with obtaining quality data
4 Why is cleaning important? to preclude your data from being qualified due to detections in associated field collected blanks
5 Cleaning Materials Analyte-free water Free of analytes of interest Uses: Final cleaning rinse Blanks Detergent Liqui-Nox, Luminox or other non-phosphate detergent, diluted Luminox is required for organics (sucralose, pharmaceuticals, pesticides)
6 Cleaning Materials Acid Rinses (metals, inorganic analytes) Reagent-grade hydrochloric acid 10% HCL Use for all non-stainless steel equipment Dispose of acids properly If Luminox is not available and organics are collected, must add rinse with pesticide grade isopropanol.
7 Handling and Containers for Cleaning Solutions Avoid contamination Use HDPE or PP containers Keep them clean, with protectors over spigots Clearly label bottles as DI water, tap water, or detergent
8 Handling Containers for Cleaning Solutions Label analyte-free water containers with date filled If logistics permit, empty all DI containers daily. At a minimum: Weekly Do not store DI water in large container for more than one week Daily Empty and refill small containers, such as squirt bottles
9 All cleaning should be done as soon as possible Lab cleaning is preferred Do not let dirty equipment sit overnight
10 General Cleaning Requirements 1. Rinse with hot tap water 2. Soak in hot soapy tap water 3. Scrub with brush to remove particulates 4. Rinse with hot tap water 5. Rinse with hydrochloric acid (except stainless steel) 6. Rinse with analyte-free water 7. Air dry, wrap and store properly
11 Cleaning Documentation Keep a cleaning log, Fig. 39 For ALL cleaning, field and lab Required Info. Specific piece(s) of equipment Date (& time if field cleaned) Location (lab or field) Procedure Name of person performing cleaning
12 Field Cleaning Materials Tap water DI water Tub or container for soaking Scrub brush Luminox solution
13 GW Field Cleaning Protect equipment use plastic ground cover Clean with soapy water and brush Rinse well with DI water
14 GW Cleaning: Pumps Purging Only Flush with Tap/DI water before and after purging Scrub exterior of pump/tubing that may contact formation water Purging & Sampling Disassemble (if able) and decontaminate If pump cannot be disassembled, then follow these next steps:
15 GW Cleaning: Pumps 1. Fill dedicated container with sudsy Tap water 2. Pump 3 volumes through tubing 3. Use sudsy water to clean outside 4. Pump DI water through tubing 5. Protect clean pump
16 New Tubing GW Cleaning: Tubing If certified clean ok If not, soak in hot soapy water, rinse with hot tap water and then DI water Wrap/store in clean container (wrap ends with foil, seal in plastic bag) Re-used Tubing In-house cleaning Follow general cleaning procedure
17 Surface Water Cleaning: Van Dorn 1. Half fill Van Dorn with tap water and Luminox 2. Shake well, brush 3. Drain some through spigot 4. Dump soapy water
18 Surface Water Cleaning: Van Dorn 5. Rinse Van Dorn thoroughly with tap water 6. Rinse with HCI acid 7. Rinse with DI water 8. Rinse through spigot 9. Air dry 10. Store in a clean container or bag
19 Sediment Cleaning (Ekman, P. Ponar, corer, HDPE scoops & forceps) 1. Rinse Pour tap water over the equipment into dedicated tub or cooler. 2. Soak & Scrub with brush. Use dedicated pump spray bottle of Luminox/DI water to spray inside and out
20 Sediment Cleaning (Ekman, P. Ponar, corer, HDPE scoops & forceps) 3. Dispose soapy water, rinse tub 4. Pour 5 gal. tap water over equipment into tub 5. Dunk 4-5 times, working jaws 6. Rinse tub 7. Pour 5 gal. DI water over equipment into tub 8. Dunk 4-5 times, working jaws 9. Store in clean bag or container Reminder: you must clean between sediment sampling sites, both at small lakes, and all sites on a large lake
21 Heavily Contaminated Equipment If sampling site is heavily contaminated, contact Tallahassee WMS For example: while purging a well, samplers may see or smell obvious contamination (not including Sulfur) If equipment comes in contact with contaminated site, use DEP SOP FC 1120, document contamination, & contact Tallahassee WMS
22 QUESTIONS? Do you want to clean the equipment or should I do it?
Laboratory Glassware Cleaning and Storage
General 07_02_01.004 Dates Active: March 14 th, 2018 - Present Author: Victoria Wickham Laboratory Glassware Cleaning and Storage 1 INTRODUCTION The proper care and cleaning of laboratory glassware is
More informationTitle: Glassware Cleaning Copy No: ## SOP No.: 3.02/2.6/S Effective Date: June 18, 2013 Location: ### Glassware Cleaning
1. Introduction Glassware Cleaning QSM Approval: All glassware used in the analysis of toxic organic compounds at the trace and ultra-trace level must be scrupulously cleaned as soon as possible after
More informationSTANDARD OPERATING PROCEDURE EQUIPMENT DECONTAMINATION PROCEDURES
1.0 INTRODUCTION STANDARD OPERATING PROCEDURE EQUIPMENT DECONTAMINATION PROCEDURES This Standard Operating Procedure (SOP) was prepared to direct field personnel in the methods for decontamination of field
More informationHAVE A SAMPLING AND ANALYSIS PLAN (SAP)
THE HOW TO OF SAMPLING, TRANSPORTING, AND DELIVERY HAVE A SAMPLING AND ANALYSIS PLAN (SAP) INCLUDE SAMPLING LOCATIONS NUMBERS AND TYPES OF SAMPLES TO BE COLLECTED QUALITY CONTROL REQUIREMENTS OF THE PROJECT
More informationCLEANING. Application Recommendations. Application/ Concerns. Articles Cleaned/ Soil Removed. Recommended Detergent. Cleaning Method.
CLEANING Application Recommendations Application/ Concerns Laboratory Reproducible results, no interfering residues, extending equipment life. Keep laboratory accreditation. Laboratory safety. Articles
More informationAmerimade RCA Wet Bench SOP Page 1 of 13 Rev /22/2014
Amerimade RCA Wet Bench SOP Page 1 of 13 Bench Features: Amerimade RCA Wet Bench SOP Tanks 1, 2 and 4 are dedicated to RCA Process (HF, SC1, SC2) batch/bulk cleans. All SC1/SC2 use of the bench will incur
More informationProcedures for Preparing and Receiving PUF Canisters and Filters
QSM Approval: Procedures for Preparing and Receiving PUF Canisters and 1. Introduction This Standard Operating Procedure provides instructions for preparing PUF canisters and filters for shipment to field
More informationPERFORM Operating Document
PERFORM Operating Document Use and Maintenance of Tuttnauer Table-Top Autoclave PC-POD-CA-006-v03 Revision History Version Reason for Revision Date 01 New POD 13-Aug-13 02 POD Section 3.1.3 and 3.2 revised
More informationSanitation Plan Workbook
Sanitation Plan Workbook Contents Overview of this Workbook 1 Part 1: Cleaning and Sanitizing Requirements 2 Part 2: Cleaning and Sanitizing Agents Used in the Establishment 3 Part 3: Identification of
More informationWashroom care programs
Washroom care programs Table of contents The basics..1 Combining substances...2 Cleaners classification... 6 All day maintenance..12 Daily maintenance......13 Periodic maintenance.....23 Emergency maintenance...
More informationPolypro Acid Wet Bench UCLA Nanolab Yellow Room. Primary contacts: Max Ho, Wilson Lin. PREPARED BY: Steve Franz DATE Rev 2/01/12
Polypro Acid Wet Bench UCLA Nanolab Yellow Room Primary contacts: Max Ho, Wilson Lin PREPARED BY: Steve Franz DATE Rev 2/01/12 1 PolyPro Acid Wet Bench 1.0 SCOPE This document establishes the procedures
More informationAUC Cell Washer. User Manual
AUC Cell Washer User Manual WARRANTY Spin Analytical Inc., warrants this product to be defect free in both material and workmanship for 90 days from the date of shipment. Labor services are guaranteed
More informationCleaning Procedures in ICP-MS Laboratories
Cleaning Procedures in ICP-MS Laboratories QSM Approval: 1. INTRODUCTION and SCOPE 1.1. This Standard Operating Procedure provides instructions for cleaning of the regular labware, microwave digestion
More informationBEFORE FIRST USE: TABLE OF CONTENTS
Chill Out Ice Maker BEFORE FIRST USE: To prevent any internal damage, it is very important to keep refrigeration units (like this one) upright throughout their journey. Please leave it standing upright
More informationUser s Manual. Electric Kettle Model MJ-EK5AEU (UK) Household Use
Electric Kettle Model MJ-EK5AEU (UK) Household Use User s Manual Thank you for your purchase. Please read this User s Manual before using this product. Retain this User s Manual for future reference. Contents
More informationBravo Display Warning Messages
Bravo Display Warning Messages The sterilizer periodically reminds the user about recommended routine maintenance operations that must be carried out in order to ensure the proper operation of the device.
More informationGeneral Acids/Bases Bench Right and Left SOP
General Acids/Bases Bench Right and Left SOP Rev. 5.0 6/2/2016 Page 1 of 6 Bench Features: General Acids/Bases Bench Right and Left SOP The bench consists of 2 independent sides so that 2 users may use
More informationCleaning & Care. Washing Breast Pump Parts
Cleaning & Care Cleaning & Care Note: These guidelines are for use with a healthy, full-term baby and assume that you have access to potable water. If your baby is premature or has health challenges your
More informationBOUMATIC ROBOT AND THE LELY SAMPLE
BOUMATIC ROBOT AND THE LELY SAMPLE Boumatic Robot Sampler Page 1 Boumatic Sampling Steps 2 Double-Click Box id 1 Click Service to pause robot 3 Click Shut to open the sample valve. Hook up milk line in
More informationUridan. Product Information. Uridan Waterless Urinals. Technical Details On Reverse Of Page
Product Code: Product Info: Uridan Uridan Waterless Urinals Technical Details On Reverse Of Page Benefits Technical Information: Uridan is Australia s leading brand of waterless urinal, widely acclaimed
More informationApplication Data Sheet
Application Data Sheet Chemical Cleaning after Thinning, Backside Grinding, Lapping, or Polishing of Silicon or Gallium Nitride Substrates Wafer cleaning after thinning, backside grinding, polishing, or
More informationPREPARED BY: Jeff Geraci, Environmental Scientist I. REVISED BY: Kristina Davis, Environmental Scientist III
DOCUMENT TYPE: TITLE: Standard Operating Procedure Redi-Flo Performance Pumps PREPARED BY: Jeff Geraci, Environmental Scientist I REVISED BY: Kristina Davis, Environmental Scientist III REVIEWED BY: Jan
More informationNewcastle Hospital NHS Foundation Trust Control of Infection Committee Water Coolers and Ice-Making Machines Policy
Newcastle Hospital NHS Foundation Trust Control of Infection Committee Water Coolers and Ice-Making Machines Policy Effective September 2006 Review September 2009 Due to concerns regarding the microbiological
More informationINSTRUCTION MANUAL. Blue Whale Spa Ltd, 11 Glaisdale Drive East Nottingham, NG8 4GU
INSTRUCTION MANUAL Balboa 500DZ-Series Operation Guide Initial Start-up Your spa will enter Priming Mode ( ) when it is energized. During Priming Mode, press Jets button(s) repeatedly and be sure all pumps
More informationSanitation and Postharvest Handling Decision Tree
Do you sort, package, wash, or grade produce in a packing house, shed, or other structure? 1 Regardless of where you pack produce, sanitation practices are going to be important to produce safety. Field
More informationWashroom care programs
Washroom care programs Table of contents The basics..1 Combining substances...2 Cleaners classification... 6 All day maintenance..12 Daily maintenance......13 Periodicmaintenance.....23 i Emergency maintenance...
More informationDevice Reprocessing Checklist Scoring Matrix 1=low 5=high
Measure Standard Q1 Q2 Q3 Q4 Point of Use Gross Debris Removed during & after procedure (use of water preferred) 5 Delicate instruments on top of heavy or separate 5 Devices contained & identified as biohazard
More informationTHERMO POT MODEL: ETP-D4013(WH)/ ETP-D5013(WH)/ ETP-D6013(WH) Owner s Manual. Please read this manual carefully before operating your set.
THERMO POT MODEL: ETP-D4013(WH)/ Owner s Manual ETP-D5013(WH)/ ETP-D6013(WH) Please read this manual carefully before operating your set. Retain it for future reference. Record model number and serial
More informationSCIF SOP for BSL 2 samples on Aria3
Date Last Modified: July 2, 2015 Author: David Gravano SCIF SOP for BSL 2 samples on Aria3 Overview of BSL-2+ Sorting Area and Procedures: This document aims to provide a description of the facility, instrumentation,
More informationTHERMO POT MODEL: ETP-C3211(WH) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.
THERMO POT MODEL: ETP-C3211(WH) Owner s Manual Please read this manual carefully before operating your set. 1 Retain it for future reference. Record model number and serial number of the set. See the label
More informationDianne Harrison, Supervisor QA Lab
Housekeeping Tasks and Contamination Control in an Animal Facility Dianne Harrison, Supervisor QA Lab Microorganisms Invisible to the naked eye Need a microscope to see Most common we deal with? Bacteria,
More informationPROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE
THEATRE AND STERILE PROCEDURES WALLS/TILES - Wash all surfaces from top to bottom using F10CLXD, rinse with - Wash off visible dirt (e.g. blood) using F10CLXD CHAIRS - Trigger spray using F10CL and wipe
More informationStandard Operating Procedures (SOPs)
Standard Operating Procedures (SOPs) for Food Business Operators Table of Contents 1. Employee Illness and Injury SOP... 4 2. Personal Hygiene SOP... 6 3. Hand washing and Glove Use SOP... 8 4. Purchasing
More informationStainless Steel Cup. Instructions. Lunch Cup MODEL. Replacing and purchasing consumable parts. Before contact customer service.
Replacing and purchasing consumable parts The lid unit, inner lid gasket, valve, clear cup, clear cup outer lid, and clear cup outer lid gasket are consumable parts. (These parts may be damaged as they
More information5. Drain excess liquid and allow to air dry. KEEP OUT OF REACH OF CHILDREN DANGER
PRECAUTIONARY STATEMENTS : Corrosive. Causes irreversible eye damage. Do not get in eyes, on skin, or on clothing. Harmful if inhaled. Avoid breathing dust. Wear gloves and protective eyewear such as goggles,
More informationTHE NEXT GENERATION CARBOY
EZgrip Carboy VersaCap VersaBarb Spigot Technology Advanced fluid handling systems developed with the end-user in mind. THE NEXT GENERATION CARBOY EZgrip Carboy Foxx Life Sciences EZgrip carboy is an advanced
More informationOzone System Maintenance Instructions
Ozone System Maintenance Instructions Congratulations on your purchase. If you have any questions please call. Regular cleaning of your system's filter and diffuser is important to keep your system operating
More informationArticle begins on next page
Sanitizing Product Contact Surfaces for Fresh Produce Production Rutgers University has made this article freely available. Please share how this access benefits you. Your story matters. [https://rucore.libraries.rutgers.edu/rutgers-lib/53606/story/]
More informationTURBOWASH TM... Pot and Pan Sink
TURBOWASH TM... Pot and Pan Sink MODEL TW ML-110644 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 33800 Rev. A (4-98) Installation, Operation, and Care of TurboWash TM Pot and Pan Sink SAVE THESE INSTRUCTIS
More informationT1 SCRUBBER DRYER OPERATOR MANUAL
T1 SCRUBBER DRYER OPERATOR MANUAL Clemas & Co. Unit 5 Ashchurch Business Centre, Alexandra Way, Tewkesbury, Gloucestershire, GL20 8NB. Tel: 01684 850777 Fax: 01684 850707 Email: info@clemas.co.uk Web:
More informationUse a dry, soft-bristle brush to dust fabric weekly to remove dirt before it becomes embedded.
Fabric Vacuum fabric regularly to remove any dust/dirt. Avoid direct sunlight and weather exposure to keep the fabric looking new. Tend to spills as soon as possible with a damp cloth. For tough stains
More informationAPPLICATION NOTE NO. 2D Revised October Instructions for Care and Cleaning of Conductivity Cells
Sea-Bird Electronics, Inc. 13431 NE 20 th Street Bellevue, WA 98005 USA Phone: (425) 643-9866 Fax: (425) 643-9954 E-mail: seabird@seabird.com Web: www.seabird.com APPLICATION NOTE NO. 2D Revised October
More informationThank you for choosing the Motif Duo Double Electric Breast Pump. Motif Duo Operation Manual
Thank you for choosing the Motif Duo Double Electric Breast Pump. Motif Duo Operation Manual Motif Medical 8 The Green Suite #5601 Dover, DE 19901 Phone: (844) 7-8390 Email: info@motifmedical.com Web:
More information4/8/2014 GOAL PATIENT EQUIPMENT
Module G APPLICATION OF CLEANING, DISINFECTION AND STERILIZATION PRINCIPLES TO PATIENT CARE EQUIPMENT IN OUTPATIENT HEALTHCARE SETTINGS GOAL Understand how to apply the principles of disinfection and sterilization
More informationJennings Street School
Infection Prevention and Control and Protocols Rationale Following standard infection control precautions can minimise the risk of norovirus outbreaks caused by person-to-person transmission in any institution
More informationPROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE
THEATRE AND STERILE PROCEDURES WALLS/TILES - Wash all surfaces from top to bottom using F10SCXD, rinse with - Wash off visible dirt (e.g. blood) using F10SCXD CHAIRS - Trigger spray using F10SC and wipe
More informationLayout and Design by T. Palimenio, Picture credit: Freepik. Cleaning Manual
Layout and Design by T. Palimenio, Picture credit: Freepik Cleaning Manual Solution Recipes Vinegar/Water Solution 4 cups Water 1 cup Vinegar Vinegar/Soap Solution 1 cup Dish Soap 1 cup Vinegar Vinegar/Water
More informationAll products are colour coded for easy identification
DAIRY INDUSTRY All products are colour coded for easy identification APPLICATION PRODUCT TEMP STRENGTH TIME CIP Water Rinse Water Cold - 5 8 Min (Pipelines) Cleaning Cycle Chlor-NF Cold 1:200-1:50 5 8
More informationU S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information
Health Information U S E R G U I D E Home Respiratory Equipment Cleaning Guide This document is intended for Patients and Families for use at home The goal of the cleaning guide is to properly handle,
More informationRequests for Daily Care and Maintenance
Inkjet printer SIJ-320UV Requests for Daily Care and Maintenance This machine is a precision machine equipped with extremely fine mechanisms. Especially, the nozzle surface of the heads from which the
More informationSafety Lab Goggles are required! Apron is optional!
Goggles are required! Apron is optional! Station 1: What would acid do to your eye? Materials: 6M hydrochloric acid, dropper, two petri dishes, egg whites. Procedure: 1. Separate the egg white from the
More informationOwner s Guide Installation & Operation
Owner s Guide Installation & Operation Fryer HFR Series Hestan Commercial Corporation 3375 E. La Palma Ave Anaheim, CA 92806 (888) 905-7463 RETAIN THIS MANUAL FOR FUTURE REFERENCE P/N 002137 REV 1 IMPORTANT
More informationSTUDENT SAFETY RULES
STUDENT SAFETY RULES Purpose Science is a hands-on laboratory class. You will be doing many laboratory activities that require the use of hazardous chemicals. Safety in the science classroom is the #1
More informationEMERGENCY RESPONSE GUIDE IMMEDIATE EMERGENCY PROCEDURES
FIRE RADIATION SPILL PERSONAL INJURY CHEMICAL SPILL BIOLOGICAL SPILL Exterior Laboratory Hallway Sign EMERGENCY RESPONSE GUIDE Research and Graduate Studies Manager Laboratory Safety 330-672-4996 tom@rags.kent.edu
More informationSKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS
SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS CAUTION: The following instructions are for all Sklar Coated stainless steel instruments. Read instructions prior to use. Improper
More informationTRAINING AND EQUIPMENT MANUAL 311 PERSONAL PROTECTIVE EQUIPMENT FIREFIGHTER PROTECTIVE CLOTHING CLEANING PROCEDURES EFFECTIVE: OCTOBER 2007
TRAINING AND EQUIPMENT MANUAL 311 PERSONAL PROTECTIVE EQUIPMENT 311.005 FIREFIGHTER PROTECTIVE CLOTHING CLEANING PROCEDURES EFFECTIVE: OCTOBER 2007 These procedures are written to prevent repeated exposure
More informationCORRECT ENDOSCOPE REPROCESSING
CORRECT ENDOSCOPE REPROCESSING Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham HIRL Birmingham 1 Inadequate decontamination procedures and
More informationRecyclables and How to Prepare Them
Recyclables and How to Prepare Them Below is an overview of the materials that may be recycled. CARDBOARD Standard Boxes, Pizza Boxes, Food Boxes, Packaging These items may be recycled as long as they
More informationHaz Waste Management
Northern California Nanotechnology Center Haz Waste Management Process: Once finished with a hazardous chemical, you will need to dispose of it by aspiration, decanting or bottling. Aspirate whenever possible!
More informationCQUBE EVO OPERATION MANUAL EVO_OM_VKI_EN. Part No.: _06
EVO_OM_VKI_EN Part No.: 1764212_06 CQUBE EVO OPERATION MANUAL CONTENTS GENERAL INFORMATION...3 Introduction... 3 Warnings... 3 Precautions... 4 Intended use... 4 Hazard intensity levels... 4 Facts & weight...
More informationArabidopsis Growing Protocol-A General Guide Xiyan Li *
Arabidopsis Growing Protocol-A General Guide Xiyan Li * Department of Genetics, Stanford University, Stanford, USA *For correspondence: lixiyan@stanford.edu [Abstract] Arabidopsis as the model organism
More informationChBE Safety Training. July Emily Edwards Lab Coordinator Chemical & Biological Engineering Tufts University 4 Colby St., Room
ChBE Safety Training July 2016 Emily Edwards Lab Coordinator Chemical & Biological Engineering Tufts University 4 Colby St., Room 151 617-627-2172 Required Training Chemical Safety Choose 1 of 3 Options
More information2015 Myco Industries, Inc Fax:
Endoscope Cleaning and Handling It is highly important that you manually clean the endoscope immediately after it is removed from the patient, BEFORE it is automated or manually disinfected. Cleaning your
More informationAll purpose Cleaner I. All-purpose Cleaner II. Drain Cleaner. 1 quart of warm water. clear water. 1 Tbsp. ammonia* 4 Tbsp.
All purpose Cleaner I 4 Tbsp. baking soda 1 quart of warm water Dissolve baking soda in warm water. Apply with a sponge. Rinse with clear water. All-purpose Cleaner II 1 Tbsp. ammonia* 1 Tbsp. liquid detergent
More information* * English. Operator Manual. Carpet Cleaner Rev. 01 ( ) Model V
R3 Carpet Cleaner English Operator Manual Model 9004199-230V R For the latest Parts manuals and other language Operator manuals, visit: www.tennantco.com/manuals 9003707 Rev. 01 (07-2016) *9003707* OPERATION
More informationCommit 2 Clean TM/MC. Restroom Care
Commit 2 Clean TM/MC Restroom Care Commit 2 Clean TM/MC Restroom Care Program Table of Contents Restroom Cleaning Procedures... 2-3 Process... 4-6 Daily Cleaning Inside the Restroom... 7-11 After Cleaning...
More informationUltrasonic Cool Mist Humidifier
Model No.: LV400CH Ultrasonic Cool Mist Humidifier Questions or Concerns? Please contact us Mon-Fri 9:00AM-5:00PM PST at (888) 726-8520 or email support@levoit.com Thank you. Thank you for purchasing
More informationHarvey Chemiclave 5000 Owner And Operator Guide
Is Happy To Present You With This Free Copy Of The Harvey Chemiclave 5000 Owner And Operator Guide Be sure to look to us when it is time to order parts and supplies for your Chemiclave Please Note: Even
More informationPERFORM Operating Document. General maintenance of Stoves, Fridges and Pots and Pans in the Nutrition Suite
PERFORM Operating Document General maintenance of Stoves, Fridges and Pots and Pans in the Nutrition Suite PC-POD-NS-007-v03 Revision History Version Reason for Revision Date 03 Name change in Authorization
More informationOPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405
CARBON SPOT 30 EXTRACTOR OPERATOR'S MANUAL IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405 Diamond Products www.diamondproductsus.com Printed in the U.S.A.
More informationSPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000
SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000 TM INSTALLATION AND OWNER S MANUAL C O N T E N T S I. Introduction II. Product Dimensions III. Installation IV. Operation in Emergency Situation V. Periodic
More informationFOOD PREMISES INSPECTION REPORT for Non-Compliant Critical / Non-Critical Items. Sushi Island 210 Water Street, St. John's, NL.
/ Items For additional information on the process, please see: Food - Annual Mar 21, 2018 601 - Food contact surfaces properly constructed or located, acceptable material Do not use cardboard as a surface
More informationULTRASONIC HUMIDIFIER WITH ANTIBACTERIAL TANK & BASE Instruction Manual and Warranty Information IM0012A READ AND SAVE THESE INSTRUCTIONS
ULTRASONIC HUMIDIFIER WITH ANTIBACTERIAL TANK & BASE Instruction Manual and Warranty Information IM0012A READ AND SAVE THESE INSTRUCTIONS Contents Safety Instructions... 1 Specifications / Parts & Contents...
More informationVENDING PROVEN HYGIENE & CLEANING FOR WATER COOLERS. Performance Focus. Recommended Products
PROVEN HYGIENE & CLEANING FOR WATER COOLERS A powerfully effective and user friendly range of products widely used by machine manufacturers, distributors and vending operators to professionally clean all
More information60+ NEED-TO-KNOW APPLIANCE MAINTENANCE TIPS
0+ NEED-TO-KNOW APPLIANCE MAINTENANCE TIPS Routine maintenance is the best way to get the most out of your appliances. You probably know you should clean the lint filter every time you use the dryer and
More informationHot Chocolate Dispenser
Hot Chocolate Dispenser Instruction manual Model: CN219-A AU Telephone Helpline: 1300225960 Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation
More informationCleaning and Sanitation Procedures Module Deli
Deli Triple Sink System (Clean, Rinse, Sanitize) A. Preparation 1) Wash your hands with anti-microbial soap before and after cleaning and whenever hands are dirty. 2) Dawn appropriate PPE s 3) Place safety
More informationR I T Title: Manual Processing Bench #2 Semiconductor & Microsystems Fabrication Laboratory Revision: C Rev Date: 08/05/2008
R I T Title: Manual Processing Bench #2 Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the Manual Processing Bench #2 for wet cleaning
More informationCLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0040A
CLEAN MIST ULTRASONIC HUMIDIFIER Instruction Manual and Warranty Information IM0040A READ AND SAVE THESE INSTRUCTIONS Contents Safety Instructions... 1 Unpacking / Specifications... 2 Parts & Contents...
More informationphd Countertop UltraWater Owner s Manual Delicious Great Tasting Antioxidant Alkaline Energized
Owner s Manual UltraWater phd Countertop Delicious Great Tasting Antioxidant Alkaline Energized Warning: Incorrect installation and/or operation could void your valuable warranty. Please protect your investment!
More informationPDMS Casting Station Supplies
PDMS Casting Station Supplies These are provided by the CNF. Please do not use more than you need. Please do not take extra supplies from the lab. Log onto CORAL each time that you use PDMS and the PDMS
More informationBeverage Ice Chests DB, DBC, FB, FBC, 1522 & 2123
Beverage Ice Chests DB, DBC, FB, FBC, 1522 & 2123 Installation, Use & Care Manual This manual is updated as new information and models are released. Visit our website for the latest manual. www.manitowocfsg.com
More informationHOME DIFFUSER OPERATION MANUAL. Languages. English 2 Español 8 Chinese 14
HOME DIFFUSER OPERATION MANUAL Languages English 2 Español 8 Chinese 14 Overview Mannatech s Serenity Home Diffuser functions as a humidifier, atomizer and aroma diffuser in one simple-to-use product.
More informationCleaning the internal optics surfaces
Cleaning the internal optics surfaces The face of the fiber-optic assembly and the lens are directly exposed to sample fluids inside the analyzer s flow cell. Automatic rinse cycles use high-pressure rinse
More informationREFUSE DISPOSAL INFORMATIONS County of Neumarkt (Landkreis Neumarkt i.d.opf.)
ABFALLWIRTSCHAFT LANDKREIS NEUMARKT I.D.OPF REFUSE DISPOSAL INFORMATIONS County of Neumarkt (Landkreis Neumarkt i.d.opf.) THE PROBLEM The mountain of waste is still growing. Environmental pollution and
More informationSteroklorPlus. Cleaner Sanitizer 3IN1Disinfectant KEEP OUT OF REACH OF CHILDREN DANGER. Mold & Mildew Killer and Stain Remover
PRECAUTIONARY STATEMENTS : Corrosive. Causes irreversible eye damage. Do not get in eyes, on skin, or on clothing. Harmful if inhaled. Avoid breathing dust. Wear gloves and protective eyewear such as goggles,
More informationWARNING: Product view. Cleaning fluid. Carry Handle. Power Button Formula & Clean Water Tank. Dirty Water Tank. Power Cord. Quick Release Cord Wrap
Product view Carry Handle Power Button Formula & Clean Water Tank Dirty Water Tank Power Cord Quick Release Cord Wrap Flex Hose To reduce the risk of fire and electric shock due to internal component damage,
More informationTOASTER OVEN INSTRUCTION MANUAL. Model: MCSTO6B. 6 Slice
TOASTER OVEN 6 Slice INSTRUCTION MANUAL Model: MCSTO6B THANK YOU FOR PURCHASING A MAGIC CHEF PRODUCT. PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE USING THE PRODUCT. CONTENTS SAFETY INSTRUCTIONS.... 3
More informationSpecial Precautions Isolation Plan Environmental Services
Special Precautions Isolation Plan Environmental Services When page is received that suspect Ebola patient has arrived in ED: If the patient is not going to be admitted: Once patient is transferred to
More informationsolargrow Instructions solargrow Phone: Never too much and never too little
solargrow 3 Any excess drains through the pebbles back into the reservoir 2 Water & nutrients pumped from the reservoir to feed the plants Instructions 1 Solar panel triggers the pump If you require any
More informationeware Handling & Cleaning Procedures
Procedures Best practice in ware washing, equipment and hard surfaces Why am I doing this program? An important part of your job is to enhance the safety and satisfaction of your customers and co-workers.
More informationCLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A
CLEAN MIST ULTRASONIC HUMIDIFIER Instruction Manual and Warranty Information IM0036A READ AND SAVE THESE INSTRUCTIONS Contents Safety Instructions... 1 Unpacking / Specifications... 2 Parts & Contents...
More informationSAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.
TABLE OF CONTENTS Machine Components Safety Precautions Machine Set Up Machine Operation Machine Maintenance & Storage Troubleshooting Technical Specifications Parts Lists Wiring Diagram 1 2 3 3-4 5 6
More information! It is the responsibility of every team
FOOD SAFETY BASICS! It is the responsibility of every team member to serve fresh, wholesome food in a safe and sanitary environment. TYPES OF FOOD SAFETY HAZARDS BIOLOGICAL Bacteria, viruses, parasites
More informationHow to care for your water storage tank
19/05/2016 How to care for your water storage tank City of Ottawa Residents >» Water and environment >» Drinking water >» Drinking Water Quality >» How to care for your water storage tank How to care for
More informationuntil filters are dry. Once dry, place the filters shiny side up in petrislides. The petrislide do NOT need to be acid washed.
Bottle Washing LDPE bottles must be acid washed prior to use in trace element analyses. The process should take two weeks. Rinse bottles three times with house DI water. One week in 3M HCl (ACS Plus) bath.
More informationInstallation & Operating Instructions
PREMIUM Installation & Operating Instructions AQP-20SIL Signature Filtered Water Cooler Premium Selection Congratulations on your purchase of a Aquaport Signature Filtered Water Cooler This unit is easy
More informationGrowler: Best Practices and New Technologies. Charles Kyle Sierra Nevada Brewing Company
Growler: Best Practices and New Technologies Charles Kyle Sierra Nevada Brewing Company Growlers: Best Practices for Retailers, Brewers and Consumers Today s Topics: Container Type and Safety The Growing
More informationICE COOLED DISPENSER ALTA 1522 DROP-IN DISPENSER
ICE COOLED DISPENSER ALTA 1522 DROP-IN DISPENSER Operators Manual Release Date: June 10, 2013 Publication Number: 741200028OPR Revision Date: May 9, 2014 Revision: B Visit the Cornelius web site at www.cornelius.com
More informationIMPORTANT Read this manual thoroughly before using the appliance. This will ensure optimum results and maximum safety.
GB IMPORTANT Read this manual thoroughly before using the appliance. This will ensure optimum results and maximum safety. Save these instructions for future reference. IMPORTANT SAFEGUARDS Read the following
More information