LifeLine Premier RLNIE

Size: px
Start display at page:

Download "LifeLine Premier RLNIE"

Transcription

1 Serial late (Interior Top anel) LifeLine remier RLNIE with INNOVATOR Doors /N _B NSF Certified June 2010 M L M L OTION SHOWN: Lighted Facades WARNING F Terminal block NOT for case-to-case wire connection! E G Terminal Block K F G Terminal Block Item art # Description Wiring Item # B J K E C REAR D H I Field Connection B F G A Terminal Block We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. Item art # Qty Description Wiring Item # FAN ASSEMBLIES, AND THERMOSTATS A. 12W Standard Fan Assembly (1) MO Fan Motor, Evaporator FB Fan Blade 12W Optional Energy Efficient Fan Assembly (1) MO Fan Motor, Evaporator FB Fan Blade HEATERS H. HE (2) Electric Defrost Heater Front (208V) (8) HE (2) Electric Defrost Heater Rear (208V) (8) HE (2) Electric Defrost Heater End (208V) (8) I. HE (2) Drain an Heater (9) Electric & KoolGas J HE Flue Reheater (10) B. CT Standard Non-adjustable Defrost (2) Thermostat C. Optional Adjustable Refrigeration Thermostat (3) D. CT Defrost Limit Thermostat (4) E. CT Relay Control Thermostat or (5) Fan and Anti-sweat Heater Thermostat RELAYS F. RL Anti-Sweat Control Relay (6) G. Fan Control Relay () RL (208V) Electrical Defrost RL KoolGas Defrost Refer to INNOVATOR REACH-IN GLASS DOOR INSTALLATION AND SERVICE manual, /N , for Innovator and Innovator II door and frame replacement parts. NOTE: Revision B adds Facade Lighting values on page 6, updates wiring item numbers on pages 1, 8, & 15 and updates pages 1, 3, 4 & 5. Changes are underlined, circled or marked with a vertical line in the margin HUSSMANN CORORATION BRIDGETON, MO U.S.A. U.S. & CANADA MEXICO LED FIXTURES AND OWER SULY K. E ower Supply () L. Door Lamp, LED BU K Center (12) BU K Center (12) BU K End (13) BU K End (13) M. Facade Lamp, LED () BU K 29.5 In. Length BU K 30.5 In. Length NOTE: For LED lighting parts contact your Hussmann service representative at lease have your model and serial number available. /N B

2 Engineering lan Views Reach-In Narrow Island Unitized End LifeLine remier RLNIE lan View HYSICAL DATA Merchandiser Drip ipe (in.) 1 1 /4 Merchandiser Liquid Line (in.) 5 /8 Merchandiser Suction Line (in.) 1 1 /8 Dimensions shown as inches and (mm) /4 (320) 26 1 /2 (63) 99 3 /4 (2534) Relay & Terminal Block Location FRONT OF CASE 88 1 /2 (2248) Waste Outlet Clearance for Door Swing 38 1 /4 (92) Electrical Wireway Splashguard 9 1 /8 (232) Relay & Terminal Block Location 26 1 /2 (63) Clearance for Door Swing Electrical Wireway 6 (152) Electrical Wireway Water Seal 48 (1219) (18) Refrigeration Outlet 5 5 /8 (3) 60 5 /8 (1540) 63 1 /4 (160) 0 1 /8 (182) 2 3 /8 (1838) Waste Outlet Relay & Terminal Block Location Main Field Connection 54 1 /4 Electrical Terminal Block (138) 26 1 /2 (63) REAR OF CASE Clearance for Door Swing 1 3 /4 (44) 4 (102) /8 (3185) Unitized Island End merchandiser is shown above. Neither Bump Out nor Dry Goods available on island end models. Refer to chart on age 3 for detailed dimensional information. 2 of 15 U.S. & Canada Mexico LifeLine remier RLNIE with Innovator Doors

3 lan View Dimensions for LifeLine remier Options LifeLine remier RLNIE RLNIE General (A) Merchandiser Length 99 3 /4 (2534) Maximum O/S dimension of merchandiser back to front *** 2 3 /8 (1838) *** Includes bumper. Add 53 in. (1346 mm) for door swing. Width of skid rail 3 3 /4 (95) Width of Bottom Front Support 6 (152) Stub-up area between front support and splashguard 9 (229) Electrical Service* (B) RH end of merchandiser to the center of nearest knockout 4 (102) RH end of merchandiser to the center of LH knockout 88 1 /2 (2248) * NOTE: Electrical Field Wiring Connection oint is at terminal. Waste Outlet (C) Right end of merchandiser to center of waste outlet 38 1 /4 (92) RH end of merchandiser to center of waste outlet in front of case 54 1 /4 (138) Back O/S of merchandiser to center of waste outlet 63 1 /4 (160) Water Seal Edge of water seal to center of waste outlet 13 (330) Schedule 40 diameter of drip piping 1 1 /4 (32) Field installed water seal outlets, tees, and connectors are shipped with case. Refrigeration Outlet (D) RH end of merchandiser to center of RH refrigeration outlet 5 5 /8 (3) Back O/S of merchandiser to center of refrigeration outlet 60 5 /8 (1540) Outside bottom front supports from end of merchandiser (18) Center bottom front support from Centerline 48 (1219) /N _B HUSSMANN CORORATION BRIDGETON, MO U.S.A. 3 of 15

4 LifeLine remier RLNIE Facade (Installed osition) 12 1 /8 (308) Facade (Shipping osition) 94 1 /2 (2401) Installed 8 1 /2 (2222) Shipped 12 in. Straight Facade Facade Options in Cross Section ( Arched Facade Not Available ) 18 1 /8 (460) Facade (Installed osition) Facade (Shipping osition) /2 (2553) Installed 8 1 /2 (2222) Shipped 18 in. Straight Facade Island End rofile 4 of 15 U.S. & Canada Mexico LifeLine remier RLNIE with Innovator Doors

5 LifeLine remier Reach-in Narrow Island, End and Center Unitized Dimensions shown as inches and (mm). LifeLine remier RLNIE LifeLine remier RLNIE /2 (2553) Installed 18 1 /8 (460) 82 1 /4 (2089) 2 1 /8 (55) 6 (102) Frame 65 1 /2 (1664) Door 6 1 /4 (159) 18 in. Straight Facade Shown See age 4 for alternate facade heights. Facade (Installed osition) Facade (Installed osition) 18 1 /8 (460) Facade (Shipping osition) 4 (121) 8 1 /2 (2222) Shipped REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 5 F and 55% R.H. FF IC Discharge Air ( F) 0 Evaporator ( F) 19 Unit Sizing ( F) 22 Btu/hr/case FF IC arallel 8,900 9,200 Conventional 9,100 9,400 Optional Energy Efficient Fan motors reduce refrigerant load by 654 Btu/hr/case. Includes EcoShine LED lighting. DEFROST DATA FF IC Frequency (hr) Defrost Water (lb/day) (± 15% based on case configuration and product loading). ELECTRIC FF IC Temp Term ( F) Failsafe (minutes) GAS Duration (minutes) OFFTIME Not Recommended 13 1 /8 (333) Frame 3 1 /2 (89) 0 (18) (298) (160) (1540) 2 (1838) 9 (232) Standard Defrost Thermostat Close on rise: close 48 F open 33 F CONVENTIONAL CONTROLS Low ressure Backup Control FF IC CI/CO (Temp F)* 18/ 34 26/ 45 Indoor Unit Only, ressure Defrost Termination (Temp F)* Not Recommended *Use a Temperature ressure Chart to determine SIG conversions. Estimated Charge ** RLNIE 5.4 lb 86 oz 2.4 kg NSF Certification This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard # requirements for construction, materials & cleanability. **This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately 0.5 lb (8 oz / 0.2 kg). Length added to Lineup by: Each Standard End (in.) 2 Insulated artition (in.) 1 1 /2 /N _B HUSSMANN CORORATION BRIDGETON, MO U.S.A. 5 of 15

6 LifeLine remier RLNIE Hussmann recommends against frame heater cycling with Innovator doors to prevent door seals from freezing to the frames and tearing. Electrical Data Number of Fans 12W RLNIE Amperes Watts Merchandiser Evaporator Fans 120V 60Hz Standard V 50Hz Standard V 60Hz Export V 50Hz Export V 60Hz Energy Efficient V 60Hz Energy Efficient Door Anti-sweat Heaters (on fan circuit) 120V 50/60Hz Standard V 50/60Hz Export Frame Anti-sweat Heaters (on fan circuit) 120V 50/60Hz Standard V 50/60Hz Export Frame Anti-sweat Heaters (on fan circuit) 120V 50/60Hz Standard V 50/60Hz Export Minimum Circuit Ampacity 120V 60Hz Standard V 50Hz Standard V 60Hz Export V 50Hz Export V 60Hz Energy Efficient V 60Hz Energy Efficient.19 Maximum Over Current rotection 120V 20 Maximum Over Current rotection 220V 15 Defrost Drain Heaters (120V 60Hz) Export (230V 50Hz) Electric Defrost (208V 3 hase) per phase value Standard LED Lighting Hussmann EcoShine [120V] Hussmann EcoShine [220V (Export)] Optional LED Lighting (24VDC) Facade Lamps * Innovator or Innovator II 6 of 15 U.S. & Canada Mexico LifeLine remier RLNIE with Innovator Doors

7 LifeLine remier RLNIE roduct Data Recommended Usable Cube 1 (Cu Ft/Case) 8.52 ft 3 /Case ( 4.21 m 3 /Case) AHRI Total Display Area 2 (Sq Ft/Case) ft 2 /Case (12.25 m 2 /Case) Shelf Area 3 (Sq Ft/Case) ft 2 /Case (1.25 m 2 /Case) 1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 2 Computed using AHRI 1200 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann roduct Reference Guide. The standard shelf complement for this model is (5) rows of 22-inch shelves. ESTIMATED SHIING WEIGHT 5 Case RLNIE lb (kg) 1980 (900) 5 Actual weights will vary according to optional kits included. /N _B HUSSMANN CORORATION BRIDGETON, MO U.S.A. of 15

8 Wiring Diagram is per side two circuits required per case. RLNIE Front and Rear Compartment CIRCLED NUMBERS = ARTS LIST ITEM NUMBERS R = = urple = urple (2 Bands) DB = Dark = LB = Light BR =Brown Y =Yellow OR = Orange W = THESE ARE MARKER COLORS (WIRE MAY VARY.) 208V 208V V R Rear Defrost R Front Defrost R COM Fan Relay F NC F NO Fan Relay Coil 1 3 F 8 R 8 R Y 8 4 Defrost Limit 6 O.O.R. 1 Fans 9 Rod Heater (Drain) R BR Y 4 CAUTION: When multiplexing merchandisers equipped with defrost heaters, if branch circuit overcurrent protection is larger than the circuit load, then additional supplemental overcurrent protection 5 may be required per NEC Articles NEUTRAL 210 and V NEUTRAL Switch 1 OR OR 20 DB FIELD WI Defrost Termination Thermostat C.O.R. 6 5 A.S. Relay Coil Relay Control C.O.R. AS W 24 DB A.S. Relay AS NC Terminal Blocks in Front and Rear Raceway Low Temperature with Electric Defrost R R R R R R OR OR W Y BR Frame A.S. Door A.S Refer to Innovator Reach-In Glass Door, Installation and Service manual, /N , for Innovator door and frame replacement parts. Defrost Termination 2 Thermostat Refrigeration Thermostat (Optional) ink Dark 3 } To Condensing Unit ermanent Internal DEFROST HEATERS (208V) Removable External FANS & A.S. (Neutral) FANS & A.S. (Neutral) ROD HEATER (Drain) Front and Rear Compartments Connect to Main Terminal Block at Rear (see age 10). Wiring Diagram is per side two circuits required per case. 8 of 15 U.S. & Canada Mexico LifeLine remier RLNIE with Innovator Doors

9 RLNIE End Compartment CIRCLED NUMBERS = ARTS LIST ITEM NUMBERS R = = urple = urple (2 Bands) DB = Dark = LB = Light BR =Brown Y =Yellow OR = Orange W = THESE ARE MARKER COLORS (WIRE MAY VARY.) 208V 208V 1 Fan Relay Coil 3 1 R F R 4 Rear Defrost 8 2 R R 8 Front Defrost 8 3 R R 4 Defrost Limit 6 O.O.R. 5 Neutral 120V Fan Relay 1 F NC Fans BR 26 COM F NO 25 Reheater Relay Control A.S. Relay Coil 3 16 C.O.R. AS W 24 CAUTION: When multiplexing merchandisers equipped with defrost heaters, if branch circuit overcurrent protection is larger than the circuit load, then additional supplemental overcurrent protection may be required per NEC Articles 210 and 240. Refer to Innovator Reach-In Glass Door, Installation and Service manual, /N , for Innovator door and frame replacement parts. A.S. Relay AS NC V NEUTRAL Frame A.S. 22 Switch 1 OR OR 20 DB FIELD WI Defrost Termination Thermostat C.O.R. DB 12 Door A.S. 21 Defrost Termination 2 Thermostat Refrigeration Thermostat (Optional) 3 Terminal Blocks in End Raceway Low Temperature with Electric Defrost R R R R R R OR OR W Y BR ink Dark } To Condensing Unit ermanent Internal DEFROST HEATERS (208V) Removable External FANS & A.S. (Neutral) FANS & A.S. (Neutral) End Compartment Connects to Main Terminal Block at Rear (see age 10). /N _B HUSSMANN CORORATION BRIDGETON, MO U.S.A. 9 of 15

10 LifeLine remier RLNIE RLNIE Wiring Diagram for Electric Defrost Rear of Case End of Case (Two door Frame) Front of Case Standard RL terminal blocks in door frame wireway. Rear of Case End Case (Two door Frame) Front of Case Main Field Electrical Connection Rear of Case (Terminal Block Located in RH Doorframe wireway) h. B (208v) h. C (208v) Lights (120v) Fans & AS (Ntrl) Lights (Ntrl) h. A (208v) Main terminal block located in Rear wireway. Field Connections Electric Defrost Sequence - Low Temperature 1. ower from the defrost contactor energizes Defrost Heaters and 208V Evaporator Fan Relay Coil (). Relay Contacts open the fan circuit and energizes the Drain an Heater. 2. If the Defrost Heater raises internal air temperature above 90 F, the Defrost Limit Thermostat (4) will open. 3. Temperature rise of the evaporator closes the Relay Control Thermostat (5) at about 35 F, energizing 120V A.S. Relay Coil (6). This relay s contacts open the Frame and Door Heater Circuits. 4. When Defrost Termination Thermostat ends defrost period, the defrost contactor opens the Defrost Heater and Evaporator Fan Relay Coil Circuits. The Drain an Heater goes off and fans are on. 5. Temperature fall of the evaporator opens the Relay Control Thermostat (5) at about 20 F, de-energizing 120V A.S. Relay Coil (6). A.S. Relay Contacts close the Frame and Door Heater Circuits. 10 of 15 U.S. & Canada Mexico LifeLine remier RLNIE with Innovator Doors

11 Wiring Diagram is per side two circuits required per case. RLNIE Front and Rear Compartment CIRCLED NUMBERS = ARTS LIST ITEM NUMBERS R = = urple = urple (2 Bands) DB = Dark = LB = Light BR =Brown Y =Yellow OR = Orange W = THESE ARE MARKER COLORS (WIRE MAY VARY.) 120V OWER COM Fan Relay F N.C. Fan Relay F N.O. A.S. Relay A.S. COM N.C. 6 Y Defrost Limit 4 Relay Control O.O.R Evaporator Fans 1 5 C.O.R. Rod Heater (Drain) 9 A.S. Relay Coil 3 1 c c Fan Relay Coil 6 Frame A.S. Heaters Door A.S. Heaters BR Y W NEUTRAL Refer to Innovator Reach-In Glass Door, Installation and Service manual, /N , for Innovator door and frame replacement parts. 120V OWER NEUTRAL Switch 1 OR OR 20 Refrigeration Thermostat (Optional) 3 Low Temperature with Gas Defrost Terminal Blocks in Raceway OR OR W Y BR ink }To Condensing Unit Removable External FANS & A.S. (Neutral) ermanent Internal FANS & A.S. (Neutral) Front and Rear Compartments Connect to Main Terminal Block at Rear (see age 13). Wiring Diagram is per side two circuits required per case. /N _B HUSSMANN CORORATION BRIDGETON, MO U.S.A. of 15

12 RLNIE End Compartment CIRCLED NUMBERS = ARTS LIST ITEM NUMBERS R = = urple = urple (2 Bands) DB = Dark = LB = Light BR =Brown Y =Yellow OR = Orange W = THESE ARE MARKER COLORS (WIRE MAY VARY.) NEUTRAL 120V OWER COM Fan Relay F N.C. Fan Relay F N.O. Evaporator Fans 1 Reheater 10 BR Refer to Innovator Reach-In Glass Door, Installation and Service manual, /N , for Innovator door and frame replacement parts Relay Control 5 C.O.R. A.S. Relay 6 A.S. COM N.C. 10 A.S. Relay Coil 3 1 c c Fan Relay Coil Frame A.S. Heaters 6 W Door A.S. Heaters V OWER NEUTRAL Switch 1 OR OR 20 Refrigeration Thermostat (Optional) 3 Low Temperature with Gas Defrost Terminal Blocks in Raceway OR OR W Y BR ink }To Condensing Unit Removable External FANS & A.S. (Neutral) ermanent Internal FANS & A.S. (Neutral) End Compartment Connects to Main Terminal Block at Rear (see age 13). 12 of 15 U.S. & Canada Mexico LifeLine remier RLNIE with Innovator Doors

13 Gas Defrost Sequence - Low Temperature RLNIE Wiring Diagram for Gas Defrost Rear of Case closes the Fan Relay Coil () and Control Relay Coil (6) circuit. The Coil opens the Fan, Door Heater, and Frame Heater circuits, while energizing the Drain an Heater (9). 2. If the Drain an Heater (9) raises internal air temperature above 90 F, the Heater Limit Thermostat (4) will open. 3. When the defrost timer ends a defrost period, the evaporator temperature will start to fall. At about 20 F, the Control Relay Thermostat will open, de-energizing the Control Relay Coil and Fan Relay Coil (). Control and Fan Relay s will open the Drain an Heater circuits, and will close the Fan, Door Heater, and Frame Heater circuits. LifeLine remier RLNIE End Case (Two door Frame) Front of Case Standard RL terminal blocks in door frame wireway. Rear of Case End Case (Two door Frame) Front of Case Main Field Electrical Connection Rear of Case (Terminal Block Located in RH Doorframe wireway) Lights (120) Fans & AS (Ntrl) Lights (Ntrl) Fans & AS (120) New terminal block located in RH door frame wireway. 1. Defrost vapor enters evaporator causing a rise in temperature. At about 35 F the Control Relay Thermostat (5) /N _B HUSSMANN CORORATION BRIDGETON, MO U.S.A of 15

14 LifeLine remier RLNIE Optional Lighting 24VDC ower Supply EcoShine LED Lighting Circuits LIGHT SWITCH WIREWAY WHITE INUT OUTUT BLUE TERMINAL BLOCK 1 20 WHITE 3 DOOR RH SIDE COMARTMENT LED LIGHT WIRING DIAGRAM Wiring Diagrams shown are for the RLNIE Island merchandisers with 60 in. EcoShine or EcoShine Energy lus LEDs. LIGHT SWITCH WHITE INUT 12 OUTUT BLUE TERMINAL BLOCK 1 20 WIREWAY WHITE 2 DOOR END COMARTMENT LED LIGHT WIRING DIAGRAM LIGHT SWITCH WIREWAY WHITE INUT OUTUT BLUE TERMINAL BLOCK 1 20 WHITE 3 DOOR LH SIDE COMARTMENT LED LIGHT WIRING DIAGRAM of 15 U.S. & Canada Mexico LifeLine remier RLNIE with Innovator Doors

15 CIRCLED NUMBERS = ARTS LIST ITEM NUMBERS R = = urple = urple (2 Bands) DB = Dark = BR =Brown Y =Yellow OR = Orange W = LifeLine remier RLNIE Optional Lighting Circuits THESE ARE MARKER COLORS (WIRE MAY VARY.) External Facade LED Wiring Orange Orange 1 20 Terminal Block 120 VAC from Wireway Light Switch Side Input ower Supply 24VDC Output Facade LED 3 Facade LED 2 Facade LED 1 Orange Orange 120 VAC from Wireway 1 20 Terminal Block Light Switch End Input ower Supply 24VDC Output Facade LED 2 Facade LED 1 Orange Orange 1 20 Terminal Block 120 VAC from Wireway Light Switch Side Input ower Supply 24VDC Output Facade LED 3 Facade LED 2 Facade LED 1 Enclosure or Wireway WARNING All components must have mechanical ground, and the merchandiser must be grounded. = 120V OWER = 120V NEUTRAL = FIELD GROUND = CASE GROUND /N _B HUSSMANN CORORATION BRIDGETON, MO U.S.A of 15

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection!

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection! RLNIE Merchandisers with INNOVATOR Doors Warning: Terminal block NOT for case-to-case wire connection! A K L Serial late E M Technical Data Sheet /N 044404_G NS Certified November 2009 E G Terminal lock

More information

RLNIE with INNOVATOR II

RLNIE with INNOVATOR II Warning: Terminal block NOT for case-to-case wire connection! RLNIE with INNOVATOR II No Heat Doors NSF Certified April 2017 We reserve the right to change or revise specifications and product design in

More information

RL with INNOVATOR II No Heat Doors

RL with INNOVATOR II No Heat Doors RL with INNOVATOR II No Heat Doors We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding

More information

Engineering Plan Views

Engineering Plan Views LifeLine Premier RL with INNOVATOR Doors or INNOVATOR III Doors P/N 0520875_J NS Certified January 2018 OPTIONS SHOWN: Arch acade Dry Goods Storage Bump Out Partitions Warning: Terminal block NOT for case-to-case

More information

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018 RLNI with INNOVATOR Doors or Serial Plate INNOVATOR III Doors NS Certified January 2018 We reserve the right to change or revise specifications and product design in connection with any feature of our

More information

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018 RLTIM with INNOVATOR We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes,

More information

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF Freedom Line RFLN with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready M G N F J or INNOVATOR III Doors P/N 0537768_J NSF Certified May 18 A Warning: Terminal block NOT for

More information

RLT with INNOVATOR Doors

RLT with INNOVATOR Doors Refrigeration and electrical connections are on top. Overhead piping and electrical circuits are required. RLT with INNOVATOR Doors Technical Data Sheet P/N 0445823_K NSF Certified August 2013 We reserve

More information

RM with INNOVATOR Doors

RM with INNOVATOR Doors RM with INNOVATOR Doors P/N 0520868_H NSF Certified May 2017 Warning: Terminal block NOT for case-to-case wire connection! We reserve the right to change or revise specifications and product design in

More information

P/N _F NSF Certified June 2010

P/N _F NSF Certified June 2010 G C A F E FN Technical Data Sheet P/N 0465898_F NSF Certified June 2010 B D We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such

More information

RMN with INNOVATOR Doors Technical Data Sheet

RMN with INNOVATOR Doors Technical Data Sheet Merchandisers RMN with INNOVATOR Doors Technical Data Sheet P/N 0435491_J NSF Certified November 2009 G E F D A Warning: Terminal block NOT for case-to-case wire connection! C B We reserve the right to

More information

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item # G FWEL Technical Data Sheet NSF Certified January 2018 E D C H B A F J We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes

More information

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item # G C A F-L Technical Data Sheet P/N 0523702_C NSF Certified March 2017 H B E F J We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

FG-L Technical Data Sheet

FG-L Technical Data Sheet FG-L Technical Data Sheet P/N 0523821_B A NSF Certified March 2016 G DOE 2012 Energy Efficiency Compliant H C K B E We reserve the right to change or revise specifications and product design in connection

More information

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016 Technical Data Sheet NSF Certified October 2016 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the

More information

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item # Merchandisers C F M1GLE-93 Technical Data Sheet P/N 0405077_G NSF Certified July 2010 A E We reserve the right to change or revise specifications and product design in connection with any feature of our

More information

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount Freedom Line RFM with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready OPTIONS SHOWN: Lighted Facades I A H C J B F NSF Certified October 18 G Warning: Terminal block NOT for

More information

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount Freedom Line merchandisers are top mount refrigeration ready Freedom Line RFMN with INNOVATOR Doors NSF Certified January 18 OPTIONS SHOWN: Lighted Facades Warning: Terminal block NOT for case-to-case

More information

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item # FG-L Technical Data Sheet P/N 0523821_C A NSF Certified March 2017 G H C K B E We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item # FG Technical Data Sheet NSF Certified March 2017 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the

More information

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item # FWG C D E F J Technical Data Sheet NSF Certified December 2008 E G I A We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes

More information

PWEE Technical Data Sheet

PWEE Technical Data Sheet Technical Data Sheet NSF Certified October 2016 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the

More information

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet FIG-L Technical Data Sheet P/N 0523825_F NSF Certified January 2018 H C A L B F J G K M We reserve the right to change or revise specifications and product design in connection with any feature of our

More information

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount. with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready K E I P/N 0541253_J NSF Certified January 201 F L Warning: Terminal block NOT for case-to-case wire connection! J G I A

More information

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish FWG-L Technical Data Sheet P/N 0523827_D NSF Certified May 2016 DOE 20 Energy Efficiency Compliant We reserve the right to change or revise specifications and product design in connection with any feature

More information

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N H C J A F E FIG Technical Data Sheet NSF Certified March 2017 G B I We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes

More information

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG. E C D E F J G I FWG Technical Data Sheet NSF Certified June 2016 DOE 2012 Energy Efficiency Compliant A We reserve the right to change or revise specifications and product design in connection with any

More information

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016 Technical Data Sheet NSF Certified October 2016 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the

More information

RL with INNOVATOR Doors

RL with INNOVATOR Doors Merchandisers K L with INNOVATO Doors Technical Data Sheet /N 042544_M NSF Certified July 200 E Warning: Terminal block NOT for case-to-case wire connection! J A D F G C I H We reserve the right to change

More information

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item # LNG Merchandisers C A F Technical Data Sheet NSF Certified February 2007 G H I I B We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item # LG Merchandisers C A F Technical Data Sheet NSF Certified February 2007 G H I I B We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet Excel FWEGH-L Merchandiser Data Sheet P/N 0544871_D NSF Certified May 2016 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National

More information

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet Excel FWGH-L Merchandiser Data Sheet NSF Certified May 2016 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation)

More information

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet EXCEL FWEGH-L Merchandiser Data Sheet P/N 0544871_F NSF Certifi ed March 2017 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National

More information

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount. Freedom Line RFMNS with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready H B F P/N 054156_J NSF Certified January 01 C I We reserve the right to change or revise specifications

More information

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet Excel FWGH Merchandiser Data Sheet P/N 0540996_F NSF Certified January 2018 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National

More information

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017 Shown with Optional Light Bar Technical Data Sheet NSF Certified March 2017 Condensing Unit Control Panel We reserve the right to change or revise specifications and product design in connection with any

More information

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet EXCEL FWEGH Merchandiser Data Sheet P/N 0544870_D NSF Certifi ed March 2017 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National

More information

LWU Technical Data Sheet

LWU Technical Data Sheet C Merchandisers A C G F Technical ata Sheet P/N 03954J NSF Certified February 200 We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

Nosing Heater. Return Grill Heater

Nosing Heater. Return Grill Heater Insight standard field electrical connections are at the bottom of the merchandiser Insight IM1SL-L Merchandiser Data Sheet NSF Certifi ed September 2017 Fan* Defrost Heater (Below coil)* Coil* Nosing

More information

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010 Shown with Optional Light Bar Q C B P Technical Data Sheet P/N 058280_A NSF Certified November 200 A Condensing Unit J Control Panel Item Part # Description Wiring Item # H F I We reserve the right to

More information

MD Medium Temperature Self Contained Open Vertical Merchandisers

MD Medium Temperature Self Contained Open Vertical Merchandisers MD Medium Temperature Self Contained Open Vertical Merchandisers MD-14 MD-10 IMPORTANT Keep in store for future reference! Installation & Service Manual P/N 2402646_D February 2012 P/N2402646D P/N 2402646_D

More information

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases Installation & Service Manual JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases This manual has been designed to be used in conjunction

More information

NFW, NCW, NFWG, NCWG, NFWE, NCWE

NFW, NCW, NFWG, NCWG, NFWE, NCWE Installation & Service Manual WIDE ISLAND FROZEN FOOD & ICE CREAM MERCHANDISERS Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General (UL/NSF)

More information

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL FOR REACH-IN GLASS DOORS AND MULTI-DECK MERCHANDISERS INSTALLATION AND OPERATION MANUAL P/N 05035_A December 008 LED Dimmer Control Installation and

More information

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL FOR REACH-IN GLASS DOORS AND MULTI-DECK MERCHANDISERS INSTALLATION AND OPERATION MANUAL P/N 05055_A November 008 LED Dimmer Control Installation and Operation

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual NFJGCX, NCJGCX, NTJGCX, NFMJGCX, NFJGECX, NCJGECX GLASS FRONT JUMBO ISLAND FROZEN FOOD/ICE CREAM/ MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display

More information

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT ISF and ISM Low and Medium Temperature Remote and Self Contained Island Merchandisers IMPORTANT Keep in store for future reference! Installation & Service Manual P/N 0515154_B October 2010 P/N0515154B

More information

Reach-in Merchandisers

Reach-in Merchandisers Reach-in Merchandisers Medium and Low Temperature Use this manual along with door manual P/N 0425683 for cases with Innovator Doors Use this manual along with door manual P/N 3008521 for cases with EcoVision

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual NFJCX, NCJCX, NTJCX, JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases This manual has been designed to

More information

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases Installation & Service Manual THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General Installation & Service

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual N5D, N5DH, N5DL, N5DSC NARROW MULTI-DECK DAIRY/DELI MERCHANDISERS Medium Temperature Refrigerated Display Cases This manual has been designed to be used in conjunction with

More information

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French Kit P/N 3014447_A December 2016 OPTIONAL ANTI-CONDENSATE HEATER CONTROLLER FOR REACH-IN GLASS DOORS MANUAL- KIT INSTALLATION CONDENSATE HEATER Spanish 3014926 French 3014927 Door Heater Control P/N 3014447_A

More information

BCH Medium Temperature Merchandisers

BCH Medium Temperature Merchandisers BCH Medium Temperature Merchandisers Models: BCH-8S and BCH-18 (1 Door) BCH-45 (2 Door) and BCH-68 (3 Door) Installation & Service Manual IMPORTANT Keep in store for future reference! P/N 2402474_F April

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual NMFG Shown NMF / NMFG SINGLE DECK FROZEN MEAT MERCHANDISERS Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General

More information

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator)

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator) Low Temperature Frozen Food and Ice Cream Field Installed Dual Temp Operation E P Controlled (Evaporator Pressure egulator) GENEAL Model Dual Temperature Kit Application A dual temperature kit allows one

More information

MD Medium Temperature Self Contained Open Vertical Merchandisers

MD Medium Temperature Self Contained Open Vertical Merchandisers MD Medium Temperature Self Contained Open Vertical Merchandisers MD-14 MD-10 Installation & Service Manual IMPORTANT Keep in store for future reference! MANUAL - I/O SELF CONTAINED MD P/N 2402646_E December

More information

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy Upgrade Installation Manual MANUAL- KIT INSTALLATION ECOSHINE II MULTI-DECK P/N 0524791_G October 2016 Spanish 0527937 French

More information

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for Medium Temperature Meat, Delicatessen, Dairy and Produce Merchandisers Installation & Operation Manual Shipped With Case Data Sheets IMPORTANT Keep in store for P/N 0463880_S Excel Series August 2018 future

More information

F-6 Multi-deck Frozen Food Wall Merchandisers

F-6 Multi-deck Frozen Food Wall Merchandisers F-6 Multi-deck Frozen Food Wall Merchandisers Installation & Service Manual Shipped With Case Data Sheets IMPORTANT Keep in store for future reference! P/N 0518253_B October 2013 English P/N 0518253 Spanish

More information

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual GSVM Medium Temperature Self Contained Open Vertical Merchandisers IMPORTANT Keep in store for future reference! Installation & Service Manual P/N 0515275_F July 2013 P/N 0515275_F iii IMPORTANT KEEP

More information

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases Installation & Service Manual L6FA MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General Installation &

More information

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls Merchandisers Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls IMPORTANT Keep in store for future reference! Installation Operation

More information

Medium Temperature Bulk Produce and Bakery Merchandisers

Medium Temperature Bulk Produce and Bakery Merchandisers Medium Temperature Bulk Produce and Bakery Merchandisers Installation & Service Manual Shipped With Case Data Sheets IMPORTANT Keep in store for future reference! P/N 0518258_C October 2013 English P/N

More information

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference!

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference! Medium Temperature Meat, Delicatessen, Dairy and Produce Merchandisers Installation & Operation Manual Shipped With Case Data Sheets IMPORTANT Keep in store for future reference! MANUAL- I/O EXCEL MEDIUM

More information

HGL- 1, 2 & 3 BS, TS. Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers. Installation & Service Manual IMPORTANT

HGL- 1, 2 & 3 BS, TS. Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers. Installation & Service Manual IMPORTANT HGL- 1, 2 & 3 BS, TS Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers HGL-2BS IMPORTANT Keep in store for future reference! HGL-3TS Installation & Service Manual P/N

More information

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference!

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference! Æ Low Temperature Single Deck Wall & Island Merchandisers Installation & Operation Manual Shipped with Merchandiser Data Sheets IMPORTANT Keep in store for future reference! MANUAL- I/O EXCEL LOW TEMP

More information

RFLNS, RFMNS & RFLTM Freedom Line

RFLNS, RFMNS & RFLTM Freedom Line RFLNS, RFMNS & RFLTM Freedom Line Low or Medium Temperature Compressor Ready Tall or Narrow Footprint Reach-in Merchandisers IMPORTANT Keep in store for future reference! MANUAL- I/O FREEDOM REACH-IN Installation

More information

EcoVision Door Manual

EcoVision Door Manual EcoVision Door Manual for Reach-In (RMTD) Merchandisers Installation & Operation Manual Shipped With Case Data Sheets IMPORTANT Keep in store for future reference! MANUAL- I/O ECOVISION REACH-IN DOORS

More information

HGM-1, 2 & 3 BS, TS. Bottom / Top Mount Medium Temperature Remote and Self Contained. Installation & Service Manual. Glass Door Merchandisers

HGM-1, 2 & 3 BS, TS. Bottom / Top Mount Medium Temperature Remote and Self Contained. Installation & Service Manual. Glass Door Merchandisers HGM-1, 2 & 3 BS, TS Bottom / Top Mount Medium Temperature Remote and Self Contained Glass Door Merchandisers HGM-3BS IMPORTANT Keep in store for future reference! HGM-2TS Installation & Service Manual

More information

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB H SSGB Technical Data Sheet P/N 3018921_E EPH Certified to NSF-7 January 2018 F A C D E A G B We reserve the right to change or revise specifications and product design in connection with any feature of

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual N7DNHPL, NHDHPL, NHDHPM HIGH PERFORMANCE EXT. HEIGHT MULTI-SHELF MERCHANDISER Medium Temperature Self Serve Display Cases This manual has been designed to be used in conjunction

More information

SERIES NAV S Display Merchandisers

SERIES NAV S Display Merchandisers SERIES NAV S Display Merchandisers Medium Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT Installation & Operation Manual P/N 2400204D NAV S Series May 2006 HUSSMANN CORPORATION

More information

Service Merchandisers

Service Merchandisers Service Merchandisers Fresh Meat, Delicatessen, and Seafood Merchandisers (Includes Wedge Installation) NSF Certified Installation & Operation Manual Shipped With Case Data Sheets IMPORTANT Keep in store

More information

Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers

Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers Merchandisers Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers IMPORTANT Keep in store for future reference! Installation & Service Manual Shipped With Merchandiser

More information

Cold Deck Canopy and Shelf Lights and Retrofit Kit

Cold Deck Canopy and Shelf Lights and Retrofit Kit PAGE 1 OF 8 General Information Cold Deck LED lighting systems are intended for use inside of commercial refrigerated display merchandisers for food zone, splash zone, and non-food zones only. Cold Deck

More information

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit HCD/HMD/HCF/HMF1010R HCD/HMD/HCF/HMF1410R Order parts online www.follettice.com Drop-in Remote Condensing RIDE remote ice

More information

LTH Low Temperature Merchandisers

LTH Low Temperature Merchandisers LTH Low Temperature Merchandisers Installation & Operation Manual IMPORTANT Keep in store for future reference! MANUAL- I/O LTH SC P/N 0506146_G JUNE 2015 Spanish 0531295 French 0531296 P/N 0506146_G

More information

Service Merchandisers

Service Merchandisers Service Merchandisers Fresh Meat, Delicatessen, and Seafood Merchandisers (Includes Wedge Installation) NSF Certified Installation & Operation Manual Shipped with Technical Data Sheets IMPORTANT Keep in

More information

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit HCD/HMD/HCF/HMF1010R HCD/HMD/HCF/HMF1410R Order parts online www.follettice.com Drop-in Remote Condensing RIDE remote ice

More information

Ultra Low Front Rear Load Medium Temperature

Ultra Low Front Rear Load Medium Temperature Ultra Low Front Rear Load Medium Temperature Dairy Merchandisers Installation & Operation Manual Shipped With Case Data Sheets IMPORTANT Keep in store for future reference! P/N 0501930_G Excel Series November

More information

EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers

EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers IMPORTANT Keep in store for future reference! Installation & Operation Manual P/N 0537298_A July 2014 MANUAL- I/O ECOVISION II

More information

Low Temperature. Installation & Operation Manual. Keep in store for future reference. Single Deck Wall & Island Merchandisers P/N F

Low Temperature. Installation & Operation Manual. Keep in store for future reference. Single Deck Wall & Island Merchandisers P/N F Merchandisers Low Temperature Single Deck Wall & Island Merchandisers IMPORTANT! Keep in store for future reference. Installation & Operation Manual Shipped With Case Data Sheets P/N 0395730F Impact Series

More information

ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers

ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers Installation & Service Manual IMPORTANT Keep in store for future reference! P/N 0515154_F November 2013 Spanish 0531291 French

More information

RFLN & RFMN Freedom Line

RFLN & RFMN Freedom Line RFLN & RFMN Freedom Line Low or Medium Temperature Compressor Ready Narrow Footprint Reach-in Merchandisers IMPORTANT Keep in store for future reference! Manual - I/O Freedom RFLN & RFMN Installation &

More information

Self-Contained MERCHANDISERS. February

Self-Contained MERCHANDISERS. February Self-Contained MERCHANDISERS February 2018 Why choose Hussmann? - Hussmann s vision is to positively impact the lives of consumers by transforming the future of food retailing so that we can help you build

More information

KR Electrical Defrost Unit Coolers (PN E108318_E)

KR Electrical Defrost Unit Coolers (PN E108318_E) KR Series Electric Defrost Unit Coolers Operating and Installation Manual KR Electrical Defrost Unit Coolers (PN E108318_E) TABLE OF CONTENTS 1 LOCATION RECOMMENDATIONS... 2 2 UNIT MOUNTING... 2 3 DRAIN

More information

Glass Lids for Low Temperature Single Deck Wall & Island Merchandisers

Glass Lids for Low Temperature Single Deck Wall & Island Merchandisers Glass Lids for Low Temperature Single Deck Wall & Island Merchandisers Upgrade Installation Instruction Manual IMPORTANT Keep in store for future reference! P/N 0531456_A Excel Series April 2013 Spanish

More information

MODELS B1PA024, 030 AND 036

MODELS B1PA024, 030 AND 036 STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat

More information

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional Now available with optional ECM Motors High Efficiency / High Reliability Low rofile Unit Cooler ublication No. 100.14 January, 2008 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000

More information

N5FGA, N5NGA, N5FGNA, N5NGNA

N5FGA, N5NGA, N5FGNA, N5NGNA Installation & Service Manual N5FGA, N5NGA, GLASS DOOR MERCHANDISERS (ARDCO) Frozen Food & Medium Temp Cases With Reversible Doors This manual has been designed to be used in conjunction with the General

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Stackable Crescent Cuber Models KM-1800SAH/3 KM-1800SWH/3 KM-1800SRH/3 A Superior Degree of Reliability SERVICE MANUAL www.hoshizaki.com Number: 73131 Issued: 11-11-2005 Revised:

More information

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES Service Facts Split System Heat Pump 4A6H5049E1000B IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit.

More information

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES ENGINEERING REFERENCE SHEET NOTES "0.00" indicates that the feature is not an option on this case model LED Lights Only Cornice lights are either standard or high output Shelf lights are standard output

More information

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons ACNF Series Ceiling-Mounted Air Handlers 1½ to 2½ Tons Contents Nomenclature...2 Heat Kit Data...2 Product Specifications...3 Dimensions...5 Airflow Data...5 Wiring Diagram...6 Accessories...8 Features

More information

Parallel Rack Systems

Parallel Rack Systems Parallel Rack Systems Installation & Service Manual IMPORTANT Keep in store for future reference! P/N 0427598_B July 2013 P/N 0427598_B iii TABLE OF CONTENTS INSTALLATION Shipping Damage....................

More information

CAUTION. No-Load Performance, Controls in Normal Position

CAUTION. No-Load Performance, Controls in Normal Position Side-by-Side Refrigerator Technical Information JCD2292KT* JCD2292KT*2, JCD2295KE* JCD2295KE*2, JCD2297KE* JCD2297KE*2, JSD2695KES JSD2695KES2, JSD2695KG* JSD2695KG*0, JSD2697KE* JSD2697KE*2, MSD2660KEG*

More information

FOR SERVICE TECHNICIAN S USE ONLY

FOR SERVICE TECHNICIAN S USE ONLY F SERVICE TECHNICIAN S USE ONLY NOTE: This sheet contains important Technical Service Data. Tech Sheet Do Not Remove Or Destroy DANGER Electrical Shock Hazard Only authorized technicians should perform

More information

Installation and Operation Manual

Installation and Operation Manual series Installation and Operation Manual FGCEID GLASS DOOR REACH-IN This refrigerator conforms to the Commercial Refrigerator Manufacturers Association s Health and Sanitation Standard. series Page 2 INSTALLATION

More information

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA REFERENCE NOTES FOR ENGINEERING DATA "0.00" indicates that data is not available yet. Defrost heater 3-phase load is unbalanced. 3-Phase defrost heater data listed represent the maximum amps per phase.

More information