LWU Technical Data Sheet

Size: px
Start display at page:

Download "LWU Technical Data Sheet"

Transcription

1 C Merchandisers A C G F Technical ata Sheet P/N 03954J NSF Certified February 200 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. B C Item Part # escription Wiring Item # FAN ASSMBLIS AN THRMOSTATS A. 4W Fan Assembly () Fan Motor, Standard (MO.4400) Front & Rear Fan Blade embossing toward motor (FB.04095) nd Compartment Fan Blade embossing toward motor (FB ) B. Optional Adjustable Refrigeration Thermostat (2) C. efrost Termination Thermostat (3) (lectric efrost only) Front & nd Compartment (CT.44406) Rear (CT.440) Heater Switch (4) (Koolgas efrost only) (CT ) HATRS. Modular lectric efrost Heaters, 20V (5) Parent (H ) nd Compartment (H.4504) Item Part # escription Wiring Item # HATRS (CONTINU) F. s, lectric 20V (6) inch case (H.45046) inch case (H ) nd Compartment (H.45046) F. s, Koolgas 20V () inch case (H ) inch case (H ) nd Compartment (H ) G. Nosing Anti-sweat Heaters () inch case (ischarge) (H.45040) inch case (Return) (H ) inch case (ischarge) (H ) inch case (Return) (H.45046) nd Compartment (ischarge) (H.04062) nd Compartment (Return) (H ) NOT: Revision J corrects heater data on Page HUSSMANN CORPORATION BRIGTON, MO U.S.A. U.S. & CANAA MXICO P/N 03954J

2 ngineering Plan Views Single eck Frozen Food Wide Island with Unitized nd 9 / (25) A Front of Case (L.H.) imensions shown as inches & (mm). B H 3/4 (222) G 3/ (29) lectrical C L 6 3/4 () 9 / (25) 3 /2 (9) Waste Outlet 30 5/ () 6 /4 (59) Refrig. Outlet Base Rail Waste Outlet Access Area (Gray) (R.H.) 22 /4 (565) Water Seal (See Note*) Refrig. Outlet 5 9/6 (4) Refrig. Outlet I nd of Case 69 (53) C F /2 (200) U-90 U-3 General (A) Case Length (without ends or partitions) 9 (226) 3 /4 (346) (ach end and insulated partition adds 2 in. (5 mm) to case line up.) (B) nd of case to end compartment 4 /4 (226) 96 /4 (2445) Maximum O/S dimension of case front to rear (includes bumper) /2 (200) /2 (200) (C) Front of splashguard to O/S edge of base rail /2 (26) /2 (26) Front edge of case to O/S edge of rear base rail 69 (53) 69 (53) () Rear of case to O/S edge of rear base rail 2 /2 (3) 2 /2 (3) Width of base rail 2 /2 (64) 2 /2 (64) Stub-up area (gray) between front base rail and splashguard 5 / (94) 5 / (94) lectrical Service (lectrical Field Wiring connection point) dge of case to center of knockouts 6 3 /4 (2) 6 3 /4 (2) Front O/S edge of case to nearest knockout 9 / (25) 9 / (25) Waste Outlets () nd of case to the center of rear waste outlet 0 / (25) 5 /4 (40) (F) Center of waste outlet to O/S edge of rear base rail 3 3 /4 (95) 3 3 /4 (95) (G) nd of case to center of front waste outlet 3 (965) 3 (965) O/S edge of case to center of waste outlet 3 /4 (222) 3 /4 (222) Water Seal dge of water seal to center of waste outlet (29) (29) O/S diameter of drip pipe lines /2 (3) /2 (3) Note*: Field installed water seal outlet, tees and connectors are shipped with case. Refrigeration Outlet nd of case to center of front and rear refrigeration outlets 5 9 /6 (4) 5 9 /6 (4) (H) nd of case to center of refrigeration outlets at other end 42 5 / (03) 3 / (2245) O/S edges of case to center of refrigeration outlets 3 / (29) 3 / (29) (I) Center of refrigeration outlet to O/S edge of rear base rail /4 (32) /4 (32) 2 of 6 HUSSMANN CORPORATION, Bridgeton, MO U.S.A. Technical ata Sheet

3 Single Level Wide Island isplay, nd and Center Unitized Impact Frozen Food & Ice Cream LC imensions shown in inches & (mm). B C C N FAN COIL COIL FAN O M K G H I J M imensions A B C F G H I J K L /4 3 3/4 /2 69 / /2 4 3/4 32 / (MM) /2 3 N O 30 / (MM) RFRIGRATION ATA Note: This data is based on store temperature and humidity that does not exceed 5 F and 55% R.H. FF IC ischarge Air ( F) 2 22 vaporator ( F) Unit Sizing ( F) Btu/hr/case FF IC Parallel 90 in in Conventional 90 in in FROST ATA FF IC Frequency (hr) efrost Water (lb/case/day) 90 in in (± 5% based on case configuration and product loading). LCTRIC FF IC Temp Term ( F) 4 4 Failsafe (minutes) GAS uration (minutes) 5 OFFTIM Not Recommended Standard efrost Thermostat Close on rise: close 4 F open 33 F CONVNTIONAL CONTROLS Low Pressure Backup Control FF IC CI/CO (Temp F)* 2/ 39 2/ 39 A NSF Certification These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF ) Standard # requirements. Indoor Unit Only, Pressure efrost Termination (Temp F) Not Recommended *Use a Temperature Pressure Chart to determine PSIG conversions. PHYSICAL ATA Merchandiser rip Pipe (in.) /4 Merchandiser Liquid Line (in.) 3 / Merchandiser Suction Line (in.) / stimated Charge (lb)** 90 in in. 5.3 **This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound. Length Added to Lineup by: ach nd/partition (in.) /2 ach Contoured nd 5 P/N 03954J HUSSMANN CORPORATION BRIGTON, MO U.S.A. 3 of 6

4 Impact Frozen Food & Ice Cream lectrical ata 90 in. 3 in. Number of 4W 3 5 (nergy fficient fan motors are not available for nd or nd-compartment models) Amperes Watts 90 in. 3 in. 90 in. 3 in. vaporator 20V 60Hz Standard V 50Hz Standard NA 230V 60Hz xport V 50Hz xport V 60Hz nergy fficient V 60Hz nergy fficient NA Nosing Anti-sweat Heaters (on fan circuit) 20V 50Hz / 60Hz V 50Hz / 60Hz Cycling Anti-sweat Heaters 20V 50Hz / 60Hz NA 230V 50Hz / 60Hz NA Minimum Circuit Ampacity 20V 60Hz Standard V 50Hz Standard NA 230V 60Hz xport V 50Hz xport V 60Hz nergy fficient V 60Hz nergy fficient NA Maximum Over Current Protection 20V Maximum Over Current Protection 230V 5 5 lectric efrost Heaters 20V 60Hz Standard Front Compartment V 60Hz Standard Rear Compartment V 60Hz Standard nd Compartment V 50Hz xport Front Compartment V 50Hz xport Rear Compartment V 50Hz xport nd Compartment Koolgas s 20V 60Hz Standard V 50Hz xport NA Standard Lighting: None 4 of 6 HUSSMANN CORPORATION, Bridgeton, MO U.S.A. Technical ata Sheet

5 L lectric efrost Standard 20 V Power From efrost Contactors L2 6 Modular lectric efrost Heaters 5 6 Modular lectric efrost Heaters 5 6 Modular lectric efrost Heater 5 20V NUTRAL 20V POWR Fan efrost Termination Thermostat WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Numbers = Parts List Item Numbers Grayed components in 3 inch models only. Nosing (anti-sweat) Heater Refrigeration 3 2 Thermostat (Field Installed) Light Blue } To Condensing Unit P/N 03954J HUSSMANN CORPORATION BRIGTON, MO U.S.A. 5 of 6

6 Gas efrost Optional 20V NUTRAL 20V POWR Fan Nosing (anti-sweat) Heater Heater Switch Heater Switch 4 Heater Switch V POWR 20V NUTRAL 20V POWR 20V NUTRAL 20V POWR 20V NUTRAL 2 Refrigeration Thermostat (Field Installed) Light Blue } To Condensing Unit WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Numbers = Parts List Item Numbers Grayed components in 2 foot models only. 6 of 6 HUSSMANN CORPORATION, Bridgeton, MO U.S.A. Technical ata Sheet

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item # LNG Merchandisers C A F Technical Data Sheet NSF Certified February 2007 G H I I B We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item # LG Merchandisers C A F Technical Data Sheet NSF Certified February 2007 G H I I B We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

P/N _F NSF Certified June 2010

P/N _F NSF Certified June 2010 G C A F E FN Technical Data Sheet P/N 0465898_F NSF Certified June 2010 B D We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such

More information

RLNIE with INNOVATOR II

RLNIE with INNOVATOR II Warning: Terminal block NOT for case-to-case wire connection! RLNIE with INNOVATOR II No Heat Doors NSF Certified April 2017 We reserve the right to change or revise specifications and product design in

More information

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item # FWG C D E F J Technical Data Sheet NSF Certified December 2008 E G I A We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes

More information

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item # G FWEL Technical Data Sheet NSF Certified January 2018 E D C H B A F J We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes

More information

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG. E C D E F J G I FWG Technical Data Sheet NSF Certified June 2016 DOE 2012 Energy Efficiency Compliant A We reserve the right to change or revise specifications and product design in connection with any

More information

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish FWG-L Technical Data Sheet P/N 0523827_D NSF Certified May 2016 DOE 20 Energy Efficiency Compliant We reserve the right to change or revise specifications and product design in connection with any feature

More information

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N H C J A F E FIG Technical Data Sheet NSF Certified March 2017 G B I We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes

More information

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item # Merchandisers C F M1GLE-93 Technical Data Sheet P/N 0405077_G NSF Certified July 2010 A E We reserve the right to change or revise specifications and product design in connection with any feature of our

More information

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item # FG Technical Data Sheet NSF Certified March 2017 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the

More information

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet FIG-L Technical Data Sheet P/N 0523825_F NSF Certified January 2018 H C A L B F J G K M We reserve the right to change or revise specifications and product design in connection with any feature of our

More information

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016 Technical Data Sheet NSF Certified October 2016 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the

More information

FG-L Technical Data Sheet

FG-L Technical Data Sheet FG-L Technical Data Sheet P/N 0523821_B A NSF Certified March 2016 G DOE 2012 Energy Efficiency Compliant H C K B E We reserve the right to change or revise specifications and product design in connection

More information

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item # G C A F-L Technical Data Sheet P/N 0523702_C NSF Certified March 2017 H B E F J We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

PWEE Technical Data Sheet

PWEE Technical Data Sheet Technical Data Sheet NSF Certified October 2016 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the

More information

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item # FG-L Technical Data Sheet P/N 0523821_C A NSF Certified March 2017 G H C K B E We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

RL with INNOVATOR II No Heat Doors

RL with INNOVATOR II No Heat Doors RL with INNOVATOR II No Heat Doors We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding

More information

RLT with INNOVATOR Doors

RLT with INNOVATOR Doors Refrigeration and electrical connections are on top. Overhead piping and electrical circuits are required. RLT with INNOVATOR Doors Technical Data Sheet P/N 0445823_K NSF Certified August 2013 We reserve

More information

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016 Technical Data Sheet NSF Certified October 2016 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the

More information

RMN with INNOVATOR Doors Technical Data Sheet

RMN with INNOVATOR Doors Technical Data Sheet Merchandisers RMN with INNOVATOR Doors Technical Data Sheet P/N 0435491_J NSF Certified November 2009 G E F D A Warning: Terminal block NOT for case-to-case wire connection! C B We reserve the right to

More information

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet Excel FWEGH-L Merchandiser Data Sheet P/N 0544871_D NSF Certified May 2016 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National

More information

RM with INNOVATOR Doors

RM with INNOVATOR Doors RM with INNOVATOR Doors P/N 0520868_H NSF Certified May 2017 Warning: Terminal block NOT for case-to-case wire connection! We reserve the right to change or revise specifications and product design in

More information

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet Excel FWGH Merchandiser Data Sheet P/N 0540996_F NSF Certified January 2018 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National

More information

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet Excel FWGH-L Merchandiser Data Sheet NSF Certified May 2016 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation)

More information

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet EXCEL FWEGH Merchandiser Data Sheet P/N 0544870_D NSF Certifi ed March 2017 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National

More information

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet EXCEL FWEGH-L Merchandiser Data Sheet P/N 0544871_F NSF Certifi ed March 2017 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National

More information

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018 RLNI with INNOVATOR Doors or Serial Plate INNOVATOR III Doors NS Certified January 2018 We reserve the right to change or revise specifications and product design in connection with any feature of our

More information

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018 RLTIM with INNOVATOR We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes,

More information

LifeLine Premier RLNIE

LifeLine Premier RLNIE Serial late (Interior Top anel) LifeLine remier RLNIE with INNOVATOR Doors /N 0510312_B NSF Certified June 2010 M L M L OTION SHOWN: Lighted Facades WARNING F Terminal block NOT for case-to-case wire connection!

More information

Engineering Plan Views

Engineering Plan Views LifeLine Premier RL with INNOVATOR Doors or INNOVATOR III Doors P/N 0520875_J NS Certified January 2018 OPTIONS SHOWN: Arch acade Dry Goods Storage Bump Out Partitions Warning: Terminal block NOT for case-to-case

More information

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017 Shown with Optional Light Bar Technical Data Sheet NSF Certified March 2017 Condensing Unit Control Panel We reserve the right to change or revise specifications and product design in connection with any

More information

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount Freedom Line RFM with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready OPTIONS SHOWN: Lighted Facades I A H C J B F NSF Certified October 18 G Warning: Terminal block NOT for

More information

Nosing Heater. Return Grill Heater

Nosing Heater. Return Grill Heater Insight standard field electrical connections are at the bottom of the merchandiser Insight IM1SL-L Merchandiser Data Sheet NSF Certifi ed September 2017 Fan* Defrost Heater (Below coil)* Coil* Nosing

More information

RL with INNOVATOR Doors

RL with INNOVATOR Doors Merchandisers K L with INNOVATO Doors Technical Data Sheet /N 042544_M NSF Certified July 200 E Warning: Terminal block NOT for case-to-case wire connection! J A D F G C I H We reserve the right to change

More information

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount Freedom Line merchandisers are top mount refrigeration ready Freedom Line RFMN with INNOVATOR Doors NSF Certified January 18 OPTIONS SHOWN: Lighted Facades Warning: Terminal block NOT for case-to-case

More information

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount. with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready K E I P/N 0541253_J NSF Certified January 201 F L Warning: Terminal block NOT for case-to-case wire connection! J G I A

More information

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF Freedom Line RFLN with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready M G N F J or INNOVATOR III Doors P/N 0537768_J NSF Certified May 18 A Warning: Terminal block NOT for

More information

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount. Freedom Line RFMNS with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready H B F P/N 054156_J NSF Certified January 01 C I We reserve the right to change or revise specifications

More information

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection!

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection! RLNIE Merchandisers with INNOVATOR Doors Warning: Terminal block NOT for case-to-case wire connection! A K L Serial late E M Technical Data Sheet /N 044404_G NS Certified November 2009 E G Terminal lock

More information

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010 Shown with Optional Light Bar Q C B P Technical Data Sheet P/N 058280_A NSF Certified November 200 A Condensing Unit J Control Panel Item Part # Description Wiring Item # H F I We reserve the right to

More information

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT ISF and ISM Low and Medium Temperature Remote and Self Contained Island Merchandisers IMPORTANT Keep in store for future reference! Installation & Service Manual P/N 0515154_B October 2010 P/N0515154B

More information

NFW, NCW, NFWG, NCWG, NFWE, NCWE

NFW, NCW, NFWG, NCWG, NFWE, NCWE Installation & Service Manual WIDE ISLAND FROZEN FOOD & ICE CREAM MERCHANDISERS Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General (UL/NSF)

More information

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases Installation & Service Manual JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases This manual has been designed to be used in conjunction

More information

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference!

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference! Æ Low Temperature Single Deck Wall & Island Merchandisers Installation & Operation Manual Shipped with Merchandiser Data Sheets IMPORTANT Keep in store for future reference! MANUAL- I/O EXCEL LOW TEMP

More information

Reach-in Merchandisers

Reach-in Merchandisers Reach-in Merchandisers Medium and Low Temperature Use this manual along with door manual P/N 0425683 for cases with Innovator Doors Use this manual along with door manual P/N 3008521 for cases with EcoVision

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual NMFG Shown NMF / NMFG SINGLE DECK FROZEN MEAT MERCHANDISERS Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual NFJCX, NCJCX, NTJCX, JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases This manual has been designed to

More information

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases Installation & Service Manual L6FA MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General Installation &

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual NFJGCX, NCJGCX, NTJGCX, NFMJGCX, NFJGECX, NCJGECX GLASS FRONT JUMBO ISLAND FROZEN FOOD/ICE CREAM/ MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display

More information

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB H SSGB Technical Data Sheet P/N 3018921_E EPH Certified to NSF-7 January 2018 F A C D E A G B We reserve the right to change or revise specifications and product design in connection with any feature of

More information

F-6 Multi-deck Frozen Food Wall Merchandisers

F-6 Multi-deck Frozen Food Wall Merchandisers F-6 Multi-deck Frozen Food Wall Merchandisers Installation & Service Manual Shipped With Case Data Sheets IMPORTANT Keep in store for future reference! P/N 0518253_B October 2013 English P/N 0518253 Spanish

More information

Low Temperature. Installation & Operation Manual. Keep in store for future reference. Single Deck Wall & Island Merchandisers P/N F

Low Temperature. Installation & Operation Manual. Keep in store for future reference. Single Deck Wall & Island Merchandisers P/N F Merchandisers Low Temperature Single Deck Wall & Island Merchandisers IMPORTANT! Keep in store for future reference. Installation & Operation Manual Shipped With Case Data Sheets P/N 0395730F Impact Series

More information

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for Medium Temperature Meat, Delicatessen, Dairy and Produce Merchandisers Installation & Operation Manual Shipped With Case Data Sheets IMPORTANT Keep in store for P/N 0463880_S Excel Series August 2018 future

More information

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL FOR REACH-IN GLASS DOORS AND MULTI-DECK MERCHANDISERS INSTALLATION AND OPERATION MANUAL P/N 05055_A November 008 LED Dimmer Control Installation and Operation

More information

RFLNS, RFMNS & RFLTM Freedom Line

RFLNS, RFMNS & RFLTM Freedom Line RFLNS, RFMNS & RFLTM Freedom Line Low or Medium Temperature Compressor Ready Tall or Narrow Footprint Reach-in Merchandisers IMPORTANT Keep in store for future reference! MANUAL- I/O FREEDOM REACH-IN Installation

More information

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference!

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference! Medium Temperature Meat, Delicatessen, Dairy and Produce Merchandisers Installation & Operation Manual Shipped With Case Data Sheets IMPORTANT Keep in store for future reference! MANUAL- I/O EXCEL MEDIUM

More information

ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers

ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers Installation & Service Manual IMPORTANT Keep in store for future reference! P/N 0515154_F November 2013 Spanish 0531291 French

More information

MD Medium Temperature Self Contained Open Vertical Merchandisers

MD Medium Temperature Self Contained Open Vertical Merchandisers MD Medium Temperature Self Contained Open Vertical Merchandisers MD-14 MD-10 IMPORTANT Keep in store for future reference! Installation & Service Manual P/N 2402646_D February 2012 P/N2402646D P/N 2402646_D

More information

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator)

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator) Low Temperature Frozen Food and Ice Cream Field Installed Dual Temp Operation E P Controlled (Evaporator Pressure egulator) GENEAL Model Dual Temperature Kit Application A dual temperature kit allows one

More information

MD Medium Temperature Self Contained Open Vertical Merchandisers

MD Medium Temperature Self Contained Open Vertical Merchandisers MD Medium Temperature Self Contained Open Vertical Merchandisers MD-14 MD-10 Installation & Service Manual IMPORTANT Keep in store for future reference! MANUAL - I/O SELF CONTAINED MD P/N 2402646_E December

More information

EcoVision Door Manual

EcoVision Door Manual EcoVision Door Manual for Reach-In (RMTD) Merchandisers Installation & Operation Manual Shipped With Case Data Sheets IMPORTANT Keep in store for future reference! MANUAL- I/O ECOVISION REACH-IN DOORS

More information

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL FOR REACH-IN GLASS DOORS AND MULTI-DECK MERCHANDISERS INSTALLATION AND OPERATION MANUAL P/N 05035_A December 008 LED Dimmer Control Installation and

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual N5D, N5DH, N5DL, N5DSC NARROW MULTI-DECK DAIRY/DELI MERCHANDISERS Medium Temperature Refrigerated Display Cases This manual has been designed to be used in conjunction with

More information

HGL- 1, 2 & 3 BS, TS. Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers. Installation & Service Manual IMPORTANT

HGL- 1, 2 & 3 BS, TS. Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers. Installation & Service Manual IMPORTANT HGL- 1, 2 & 3 BS, TS Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers HGL-2BS IMPORTANT Keep in store for future reference! HGL-3TS Installation & Service Manual P/N

More information

BCH Medium Temperature Merchandisers

BCH Medium Temperature Merchandisers BCH Medium Temperature Merchandisers Models: BCH-8S and BCH-18 (1 Door) BCH-45 (2 Door) and BCH-68 (3 Door) Installation & Service Manual IMPORTANT Keep in store for future reference! P/N 2402474_F April

More information

Medium Temperature Bulk Produce and Bakery Merchandisers

Medium Temperature Bulk Produce and Bakery Merchandisers Medium Temperature Bulk Produce and Bakery Merchandisers Installation & Service Manual Shipped With Case Data Sheets IMPORTANT Keep in store for future reference! P/N 0518258_C October 2013 English P/N

More information

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls Merchandisers Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls IMPORTANT Keep in store for future reference! Installation Operation

More information

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA REFERENCE NOTES FOR ENGINEERING DATA "0.00" indicates that data is not available yet. Defrost heater 3-phase load is unbalanced. 3-Phase defrost heater data listed represent the maximum amps per phase.

More information

EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers

EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers IMPORTANT Keep in store for future reference! Installation & Operation Manual P/N 0537298_A July 2014 MANUAL- I/O ECOVISION II

More information

Self-Contained MERCHANDISERS. February

Self-Contained MERCHANDISERS. February Self-Contained MERCHANDISERS February 2018 Why choose Hussmann? - Hussmann s vision is to positively impact the lives of consumers by transforming the future of food retailing so that we can help you build

More information

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual GSVM Medium Temperature Self Contained Open Vertical Merchandisers IMPORTANT Keep in store for future reference! Installation & Service Manual P/N 0515275_F July 2013 P/N 0515275_F iii IMPORTANT KEEP

More information

RFLN & RFMN Freedom Line

RFLN & RFMN Freedom Line RFLN & RFMN Freedom Line Low or Medium Temperature Compressor Ready Narrow Footprint Reach-in Merchandisers IMPORTANT Keep in store for future reference! Manual - I/O Freedom RFLN & RFMN Installation &

More information

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES GENERAL Light controls - occupancy sensors are required Option 1: OEM Provided: OEM anti-condensate and lighting controls (on/off) are standard unless otherwise specified. Option 2: End User Provided:

More information

KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum

KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum P/N 1H52918001_B Version 1.1 May 2011 P/N_1H52918001_B P/N 1H52918001_B iii TABLE OF CONTENTS I. Overview.....................

More information

Self-Contained MERCHANDISERS. October

Self-Contained MERCHANDISERS. October Self-Contained MERCHANDISERS October 2017 Why choose Hussmann? - Hussmann s vision is to positively impact the lives of consumers by transforming the future of food retailing so that we can help you build

More information

Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers

Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers Merchandisers Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers IMPORTANT Keep in store for future reference! Installation & Service Manual Shipped With Merchandiser

More information

Service Merchandisers

Service Merchandisers Service Merchandisers Fresh Meat, Delicatessen, and Seafood Merchandisers (Includes Wedge Installation) NSF Certified Installation & Operation Manual Shipped With Case Data Sheets IMPORTANT Keep in store

More information

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases Installation & Service Manual THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General Installation & Service

More information

Parallel Rack Systems

Parallel Rack Systems Parallel Rack Systems Installation & Service Manual IMPORTANT Keep in store for future reference! P/N 0427598_B July 2013 P/N 0427598_B iii TABLE OF CONTENTS INSTALLATION Shipping Damage....................

More information

HGM-1, 2 & 3 BS, TS. Bottom / Top Mount Medium Temperature Remote and Self Contained. Installation & Service Manual. Glass Door Merchandisers

HGM-1, 2 & 3 BS, TS. Bottom / Top Mount Medium Temperature Remote and Self Contained. Installation & Service Manual. Glass Door Merchandisers HGM-1, 2 & 3 BS, TS Bottom / Top Mount Medium Temperature Remote and Self Contained Glass Door Merchandisers HGM-3BS IMPORTANT Keep in store for future reference! HGM-2TS Installation & Service Manual

More information

Ultra Low Front Rear Load Medium Temperature

Ultra Low Front Rear Load Medium Temperature Ultra Low Front Rear Load Medium Temperature Dairy Merchandisers Installation & Operation Manual Shipped With Case Data Sheets IMPORTANT Keep in store for future reference! P/N 0501930_G Excel Series November

More information

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French Kit P/N 3014447_A December 2016 OPTIONAL ANTI-CONDENSATE HEATER CONTROLLER FOR REACH-IN GLASS DOORS MANUAL- KIT INSTALLATION CONDENSATE HEATER Spanish 3014926 French 3014927 Door Heater Control P/N 3014447_A

More information

Service Merchandisers

Service Merchandisers Service Merchandisers Fresh Meat, Delicatessen, and Seafood Merchandisers (Includes Wedge Installation) NSF Certified Installation & Operation Manual Shipped with Technical Data Sheets IMPORTANT Keep in

More information

Field Top Mounted Condensing Unit

Field Top Mounted Condensing Unit Field Top Mounted Condensing Unit INSTALLATION & OPERATIONS MANUAL RF/RF-N, RM/RM-N IMPORTANT Keep in store for future reference! REVISION HISTORY VERSION 1.0 New manual This manual is specific to the

More information

Glass Lids for Low Temperature Single Deck Wall & Island Merchandisers

Glass Lids for Low Temperature Single Deck Wall & Island Merchandisers Glass Lids for Low Temperature Single Deck Wall & Island Merchandisers Upgrade Installation Instruction Manual IMPORTANT Keep in store for future reference! P/N 0531456_A Excel Series April 2013 Spanish

More information

Installation and Operation Manual

Installation and Operation Manual series Installation and Operation Manual FGCEID GLASS DOOR REACH-IN This refrigerator conforms to the Commercial Refrigerator Manufacturers Association s Health and Sanitation Standard. series Page 2 INSTALLATION

More information

SM / SN Medium and Low Temperature Spot Merchandisers

SM / SN Medium and Low Temperature Spot Merchandisers SM / SN Medium and Low Temperature Spot Merchandisers Installation & Service Manual IMPORTANT Keep in store for future reference! P/N 2400205_E October 2013 Spanish 0531305 French 0531306 P/N 2400205_E

More information

SERIES NAV S Display Merchandisers

SERIES NAV S Display Merchandisers SERIES NAV S Display Merchandisers Medium Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT Installation & Operation Manual P/N 2400204D NAV S Series May 2006 HUSSMANN CORPORATION

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers

ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers IMPORTANT Keep in store for future reference! MANUAL- I/O SELF-CONTAINED ISF AND ISM Installation & Operation Manual P/N 0515154_H

More information

N5FGA, N5NGA, N5FGNA, N5NGNA

N5FGA, N5NGA, N5FGNA, N5NGNA Installation & Service Manual N5FGA, N5NGA, GLASS DOOR MERCHANDISERS (ARDCO) Frozen Food & Medium Temp Cases With Reversible Doors This manual has been designed to be used in conjunction with the General

More information

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES ENGINEERING REFERENCE SHEET NOTES "0.00" indicates that the feature is not an option on this case model LED Lights Only Cornice lights are either standard or high output Shelf lights are standard output

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-AAX-0516A All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost

More information

SERVICE & INSTALLATION MANUAL

SERVICE & INSTALLATION MANUAL CARRIER COMMERCIAL REFRIGERATION, INC. Providing BEVERAGE-AIR FRIGIDAIRE KELVINATOR UNIVERSAL NOLIN Products/Services SERVICE & INSTALLATION MANUAL Frozen Food & Ice Cream Merchandisers CMCT 2/03 51-1021-01

More information

KR Electrical Defrost Unit Coolers (PN E108318_E)

KR Electrical Defrost Unit Coolers (PN E108318_E) KR Series Electric Defrost Unit Coolers Operating and Installation Manual KR Electrical Defrost Unit Coolers (PN E108318_E) TABLE OF CONTENTS 1 LOCATION RECOMMENDATIONS... 2 2 UNIT MOUNTING... 2 3 DRAIN

More information

LTH Low Temperature Merchandisers

LTH Low Temperature Merchandisers LTH Low Temperature Merchandisers Installation & Operation Manual IMPORTANT Keep in store for future reference! MANUAL- I/O LTH SC P/N 0506146_G JUNE 2015 Spanish 0531295 French 0531296 P/N 0506146_G

More information

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA: REFERENCE NOTES FOR ENGINEERING DATA: "0.00" indicates that the feature is not an option on this case model LED Lights Only. Cornice lights are either standard or high output. Shelf Lights are standard

More information

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker. 73105 IMPORTANT Only qualified service technicians should attempt to service or maintain this icemaker. No service or maintenance should be undertaken until the technician has thoroughly read this Service

More information

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy Upgrade Installation Manual MANUAL- KIT INSTALLATION ECOSHINE II MULTI-DECK P/N 0524791_G October 2016 Spanish 0527937 French

More information