1 Merchandisers K L with INNOVATO Doors Technical Data Sheet /N _M NSF Certified July 200 E Warning: Terminal block NOT for case-to-case wire connection! J A D F G C I H We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. Item art # Description Wiring Item # FAN ASSEMLIES, AND THEMOSTATS A. 12W Standard Fan Assembly Fan Motor, Evaporator (1) (MO ) Fan lade (F.48044) 12W Optional Energy Efficient Fan Assembly (1) 0455 Fan Motor, Evaporator (MO ) Fan lade (F.48044) Standard Non-adjustable (2) Defrost Thermostat (CT.44402) C. Optional Adjustable efrigeration Thermostat () D Defrost Limit Thermostat (4) (CT ) E elay Control Thermostat or (5) Fan and Anti-sweat Heater Thermostat (CT ) ELAS F Anti-Sweat Control elay () (L ) G Fan Control elay (208V) () (L.44802) HEATES H. Electric Defrost Heaters Front (208V) (8) (1) 1 Door Models (HE.48502) (1) 2 Door Models (HE.48504) (1) Door Models (HE.4850) (1) 4 Door Models (HE.48504) (1) 5 Door Models (HE.48502) NOTE: evision M adds more LED lighting data. 200 HUSSMANN COOATION IDGETON, MO U.S.A. U.S. & CANADA MEXICO Item art # (Qty) Description Wiring Item # HEATES (CONTINUED) H. Electric Defrost Heaters ear (208V) (8) (1) 1 Door Models (HE.48504) (1) 2 Door Models (HE ) (1) Door Models (HE ) 0489 (1) 4 Door Models (HE.48500) (1) 5 Door Models (HE.48501) I. Drain an Heater (9) Electric & KoolGas (1) 1 Door Models (HE.48504) 080 (1) 2 Door Models (HE ) 080 (1) Door Models (HE ) 0808 (1) 4 Door Models (HE ) 0809 (1) 5 Door Models (HE ) LAMS AND ALLASTS J Lamp allast (A ) Lamp allast (A ) Lamp allast (A ) Export allast (A ) K. Standard Fluorescent Lamp eplace with like fixtures NOTE: For LED lighting parts contact your Hussmann service representative at lease have your model and serial number available. efer to INNOVATO EACH-IN GLASS DOO INSTALLATION AND SEVICE manual, /N 04258, for Innovator II door and frame replacement parts. /N _M

2 Engineering lan Views each In 2,, each-in 4, & 5 Door L-M-MF Dimensions shown as in. & (mm). 1, 2,, 4 & 5 Door lan View A C D 41 9 /1 (105) Skid/External ase Waste Outlet Electrical Wireway 48 (1219) (152) ottom Frt. Support efrig. Outlet 5 /8 (142) 2 (81) 4 5 /8 (89) 9 /8 (999) 41 5 /8 (105) 4 /4 (1110) 4 (102) () Front Water Seal (see note **) elay & Terminal lock Location 4 (102) () (see note *) 1 Dr 2 Dr Dr 4 Dr 5 Dr General (A) Case Length (without ends or partitions) 1 1 /2 (800) 2 (155) 92 1 /2 (250) 122 /8 (121) 15 /8 (89) Maximum O/S dimension of case back to front 4 /4 (1111) 4 /4 (1111) 4 /4 (1111) 4 /4 (1111) 4 /4 (1111) (Includes bumper) ack of case to rear of splashguard 9 /8 (1000) 9 /8 (1000) 9 /8 (1000) 9 /8 (1000) 9 /8 (1000) Width of Skidrail 4 1 /2 (114) 4 1 /2 (114) 4 1 /2 (114) 4 1 /2 (114) 4 1 /2 (114) Width of ottom Front Support (152) (152) (152) (152) (152) Stub-up area between front skidrail and splashguard /8 (12) /8 (12) /8 (12) /8 (12) /8 (12) Electrical Service H end of case to the center of nearest knockout 4 (102) 4 (102) 4 (102) 4 (102) 4 (102) () H end of case to the center of LH knockout 2 1 /2 (98) 58 (14) 88 1 /2 (2248) 118 /8 (019) 149 /8 (94) ack O/S of case to center of knockout 41 5 /8 (1058) 41 5 /8 (1058) 41 5 /8 (1058) 41 5 /8 (1058) 41 5 /8 (1058) * NOTE: Electrical Field Wiring Connection oint is at terminal. Waste Outlet (C) ight end of case to center of waste outlet 15 /4 (400) 2 /4 (0) 54 1 /4 (18) 4 1 /4 (115) 5 /8 (194) ack O/S of case to center of waste outlet 4 5 /8 (89) 4 5 /8 (89) 4 5 /8 (89) 4 5 /8 (89) 4 5 /8 (89) Water Seal Edge of water seal to center of waste outlet 11 (29) 11 (29) 11 (29) 11 (29) 11 (29) Outside diameter of drip piping 1 1 /4 (2) 1 1 /4 (2) 1 1 /4 (2) 1 1 /4 (2) 1 1 /4 (2) ** NOTE: Field installed water seal outlets, tees, and connectors are shipped with case efrigeration Outlet H end of case to center of H refrigeration outlet 5 /8 (1) 5 /8 (1) 5 /8 (1) 5 /8 (1) 5 /8 (1) ack O/S of case to center of refrigeration outlet 2 (81) 2 (81) 2 (81) 2 (81) 2 (81) (D) Outside bottom front supports from end of case /4 (10) /4 (10) /4 (10) /4 (10) /4 (10) Center bottom front support from Centerline NA 24 (10) 24 (10) 24 (10) 24 (10) Distance between Center and Outside supports will vary 2 of HUSSMANN COOATION, ridgeton, MO U.S.A. L with Innovator Doors Technical Data Sheet

3 each-in 2,, 4 and 5 Door Models Dimensions shown as in. & (mm). Impact L With INNOVATO Doors Frozen Food & Ice Cream EFIGEATION DATA L/M/MF 82 /8 (2091) 2 (52) (100) Frame 2 1 /2 (1588) 40 /4 (105) 8 1 /2 (2120) Note: This data is based on store temperature and humidity that does not exceed 5 F and 55%.H. 2,, 4, 5 Door 1 Door FF IC FF IC Discharge Air ( F) Evaporator ( F) Unit Sizing ( F) tu/hr/door* arallel Conventional *Optional LED lighting reduces refrigeration load by 100 tu/hr/door. DEFOST DATA ALL FF IC Frequency (hr) Defrost Water (lb/dr/day) (± 15% based on case configuration and product loading.) 22 Shelf (559) ELECTIC FF IC Temp Term ( F) Failsafe (minutes) GAS Duration (minutes) /2 (140) Electrical Field Wiring Connection is at Terminal /8 (9) 1 1 /2 (8) 2 5 /8 (02) efrigeration Outlet Fan Electrical Stub-up Area 2 (81) 4 5 /8 (89) 9 /8 (999) 41 5 /8 (105) 4 /4 (1110) NSF Certification These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF ) Standard # requirements. 4 /4 (121) 2 5 /8 () OFFTIME Not ecommended CONVENTIONAL CONTOLS Low ressure ackup Control FF IC CI/CO (Temp F)** 18 / 4 2 / 45 Indoor Unit Only, ressure Defrost Termination (Temp F)** Not ecommended **Use a Temperature ressure Chart to determine SIG conversions. HSICAL DATA Drip ipe (in.) 1 1 /4 Liquid Line (in.) /8 Suction Line (in.) /8 Estimated Charge (lb)*** 1Dr 0.9 4Dr. 2Dr 1.8 5Dr 4. Dr 2. ***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound. Length Added to Lineup by each Standard End (in.) 2 Optional End with Window (in.) 1 1 /2 Optional artition (in.) 1 1 /2 /N _M HUSSMANN COOATION IDGETON, MO U.S.A. of

4 Impact L With INNOVATO Doors Frozen Food & Ice Cream Hussmann recommends against frame heater cycling with Innovator doors to prevent door seals from freezing to the frames and tearing. Electrical Data Number of Fans 12W Amperes Watts Merchandiser 1Dr 2Dr Dr 4Dr 5Dr 1Dr 2Dr Dr 4Dr 5Dr Evaporator Fan 120V 0Hz Standard V 50Hz Standard V 0Hz Export NA NA V 50Hz Export NA NA V 0Hz Energy Efficient V 0Hz Energy Efficient NA NA Door Anti-sweat Heaters (on fan circuit) 120V 50/0Hz Standard V 50/0Hz Export NA NA Frame Anti-sweat Heaters (on fan circuit) 120V 50/0Hz Standard V 50/0Hz Export NA NA Minimum Circuit Ampacity 120V 0Hz Standard V 50Hz Standard V 0Hz Export NA V 50Hz Export NA V 0Hz Energy Efficient NA V 0Hz Energy Efficient NA Maximum Over Current rotection 120V Maximum Over Current rotection 220V Defrost Drain Heaters (Export: 220V 50 hz) NA NA V Electric Defrost (Export: 220V 50 hz) NA NA Standard Vertical Lighting 1Dr 2Dr Dr 4Dr 5Dr 1Dr 2Dr Dr 4Dr 5Dr Innovator* Doors (Export: 220V 50 hz) NA NA Optional LED Lighting Gelcor Optional LED Lighting Hussmann Always*right * Innovator or Innovator II 4 of HUSSMANN COOATION, ridgeton, MO U.S.A. L with Innovator Doors Technical Data Sheet

5 Fan and Heater Circuits - Electric Defrost (standard) Low Temperature CICLED NUMES = ATS LIST ITEM NUMES = ed = urple 2 = urple (2 ands) D = Dark lue = lack =rown =ellow O = Orange W = White THESE AE MAKE COLOS (WIE MA VA.) 208V 1 2 ear Defrost Heater Front Defrost Heater 8 8 Evaporator Fan elay 1 C 8 Defrost Limit 4 O.O.. 208V 4 5 CAUTION: When multiplexing merchandisers equipped with defrost heaters, if branch circuit overcurrent protection is larger than the individual merchandiser s defrost circuit load, then additional supplemental overcurrent protection may be required per NEC Articles 210 and V OWE 120V OWE COM Fan elay F N.C. Fan elay F N.O. A.S. elay A.S. COM N.C. Switch 1 O L O 20 Defrost Termination FIELD WIED Thermostat 2 D D C.O.. elay Control NEUTAL Evaporator Fans 1 5 od Heater (Drain) 9 2 A.S. elay 1 c N.C. Frame A.S. Heaters Door A.S. Heaters Terminal locks in aceway Low Temperature with Electric Defrost 2 O O 2 W C.O W NEUTAL 2 21 efer to Innovator each-in Glass Door, Installation and Service manual, /N 04258, for Innovator door and frame replacement parts. Defrost Termination 2 Thermostat efrigeration Thermostat (Optional) ink Dark lue } To Condensing Unit ermanent Internal DEFOST HEATES (208V) emovable External FANS & A.S. (Neutral) FANS & A.S. (Neutral) Electric Defrost Sequence - Low Temperature 1. ower from the defrost contactor energizes Defrost Heaters and 208V Evaporator Fan elay (). elay Contacts open the fan circuit and energizes the Drain an Heater. 2. If the Defrost Heater raises internal air temperature above 90 F, the Defrost Limit Thermostat (4) will open.. Temperature rise of the evaporator closes the elay Control Thermostat (5) at about 5 F, energizing 120V A.S. elay (). This relay s contacts open the Frame and Door Heater Circuits. 4. When Defrost Termination Thermostat ends defrost period, the defrost contactor opens the Defrost Heater and Evaporator Fan elay Circuits. The Drain an Heater goes off and fans are on. 5. Temperature fall of the evaporator opens the elay Control Thermostat (5) at about 20 F, de-energizing 120V A.S. elay (). A.S. elay Contacts close the Frame and Door Heater Circuits. /N _M HUSSMANN COOATION IDGETON, MO U.S.A. 5 of

6 Fan and Heater Circuits - Gas Defrost (optional) Low Temperature CICLED NUMES = ATS LIST ITEM NUMES = ed = urple 2 = urple (2 ands) D = Dark lue = lack =rown =ellow O = Orange W = White THESE AE MAKE COLOS (WIE MA VA.) 120V OWE COM Fan elay F N.C. Fan elay F N.O. A.S. elay A.S. COM N.C. Defrost Limit 4 elay Control O.O Evaporator Fans 1 5 C.O.. 11 od Heater (Drain) 9 2 A.S. elay 1 c c Fan elay Frame A.S. Heaters Door A.S. Heaters W 2 NEUTAL efer to Innovator each-in Glass Door, Installation and Service manual, /N 04258, for Innovator door and frame replacement parts. 120V OWE NEUTAL Switch 1 O L O 20 efrigeration Thermostat (Optional) Low Temperature with Gas Defrost Terminal locks in aceway 2 O O 2 W ink }To Condensing Unit emovable External FANS & A.S. (Neutral) ermanent Internal FANS & A.S. (Neutral) Gas Defrost Sequence - Low Temperature 1. Defrost vapor enters evaporator causing a rise in temperature. At about 5 F the Control elay Thermostat (5) closes the Fan elay () and Control elay () circuit. The opens the Fan, Door Heater, and Frame Heater circuits, while energizing the Drain an Heater (9). 2. If the Drain an Heater (9) raises internal air temperature above 90 F, the Heater Limit Thermostat (4) will open.. When the defrost timer ends a defrost period, the evaporator temperature will start to fall. At about 20 F, the Control elay Thermostat will open, de-energizing the Control elay and Fan elay (). Control and Fan elay s will open the Drain an Heater circuits, and will close the Fan, Door Heater, and Frame Heater circuits. of HUSSMANN COOATION, ridgeton, MO U.S.A. L with Innovator Doors Technical Data Sheet

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection!

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection! RLNIE Merchandisers with INNOVATOR Doors Warning: Terminal block NOT for case-to-case wire connection! A K L Serial late E M Technical Data Sheet /N 044404_G NS Certified November 2009 E G Terminal lock

More information

LifeLine Premier RLNIE

LifeLine Premier RLNIE Serial late (Interior Top anel) LifeLine remier RLNIE with INNOVATOR Doors /N 0510312_B NSF Certified June 2010 M L M L OTION SHOWN: Lighted Facades WARNING F Terminal block NOT for case-to-case wire connection!

More information

RL with INNOVATOR II No Heat Doors

RL with INNOVATOR II No Heat Doors RL with INNOVATOR II No Heat Doors We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding

More information

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item # LNG Merchandisers C A F Technical Data Sheet NSF Certified February 2007 G H I I B We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item # LG Merchandisers C A F Technical Data Sheet NSF Certified February 2007 G H I I B We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

RLNIE with INNOVATOR II

RLNIE with INNOVATOR II Warning: Terminal block NOT for case-to-case wire connection! RLNIE with INNOVATOR II No Heat Doors NSF Certified April 2017 We reserve the right to change or revise specifications and product design in

More information

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018 RLNI with INNOVATOR Doors or Serial Plate INNOVATOR III Doors NS Certified January 2018 We reserve the right to change or revise specifications and product design in connection with any feature of our

More information

RLT with INNOVATOR Doors

RLT with INNOVATOR Doors Refrigeration and electrical connections are on top. Overhead piping and electrical circuits are required. RLT with INNOVATOR Doors Technical Data Sheet P/N 0445823_K NSF Certified August 2013 We reserve

More information

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018 RLTIM with INNOVATOR We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes,

More information

Engineering Plan Views

Engineering Plan Views LifeLine Premier RL with INNOVATOR Doors or INNOVATOR III Doors P/N 0520875_J NS Certified January 2018 OPTIONS SHOWN: Arch acade Dry Goods Storage Bump Out Partitions Warning: Terminal block NOT for case-to-case

More information

RMN with INNOVATOR Doors Technical Data Sheet

RMN with INNOVATOR Doors Technical Data Sheet Merchandisers RMN with INNOVATOR Doors Technical Data Sheet P/N 0435491_J NSF Certified November 2009 G E F D A Warning: Terminal block NOT for case-to-case wire connection! C B We reserve the right to

More information

P/N _F NSF Certified June 2010

P/N _F NSF Certified June 2010 G C A F E FN Technical Data Sheet P/N 0465898_F NSF Certified June 2010 B D We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such

More information

RM with INNOVATOR Doors

RM with INNOVATOR Doors RM with INNOVATOR Doors P/N 0520868_H NSF Certified May 2017 Warning: Terminal block NOT for case-to-case wire connection! We reserve the right to change or revise specifications and product design in

More information

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item # G FWEL Technical Data Sheet NSF Certified January 2018 E D C H B A F J We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes

More information

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item # FWG C D E F J Technical Data Sheet NSF Certified December 2008 E G I A We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes

More information

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item # G C A F-L Technical Data Sheet P/N 0523702_C NSF Certified March 2017 H B E F J We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

FG-L Technical Data Sheet

FG-L Technical Data Sheet FG-L Technical Data Sheet P/N 0523821_B A NSF Certified March 2016 G DOE 2012 Energy Efficiency Compliant H C K B E We reserve the right to change or revise specifications and product design in connection

More information

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet FIG-L Technical Data Sheet P/N 0523825_F NSF Certified January 2018 H C A L B F J G K M We reserve the right to change or revise specifications and product design in connection with any feature of our

More information

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG. E C D E F J G I FWG Technical Data Sheet NSF Certified June 2016 DOE 2012 Energy Efficiency Compliant A We reserve the right to change or revise specifications and product design in connection with any

More information

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish FWG-L Technical Data Sheet P/N 0523827_D NSF Certified May 2016 DOE 20 Energy Efficiency Compliant We reserve the right to change or revise specifications and product design in connection with any feature

More information

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item # FG-L Technical Data Sheet P/N 0523821_C A NSF Certified March 2017 G H C K B E We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item # FG Technical Data Sheet NSF Certified March 2017 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the

More information

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N H C J A F E FIG Technical Data Sheet NSF Certified March 2017 G B I We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes

More information

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount Freedom Line RFM with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready OPTIONS SHOWN: Lighted Facades I A H C J B F NSF Certified October 18 G Warning: Terminal block NOT for

More information

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF Freedom Line RFLN with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready M G N F J or INNOVATOR III Doors P/N 0537768_J NSF Certified May 18 A Warning: Terminal block NOT for

More information

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016 Technical Data Sheet NSF Certified October 2016 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the

More information

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet Excel FWEGH-L Merchandiser Data Sheet P/N 0544871_D NSF Certified May 2016 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National

More information

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010 Shown with Optional Light Bar Q C B P Technical Data Sheet P/N 058280_A NSF Certified November 200 A Condensing Unit J Control Panel Item Part # Description Wiring Item # H F I We reserve the right to

More information

LWU Technical Data Sheet

LWU Technical Data Sheet C Merchandisers A C G F Technical ata Sheet P/N 03954J NSF Certified February 200 We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item # Merchandisers C F M1GLE-93 Technical Data Sheet P/N 0405077_G NSF Certified July 2010 A E We reserve the right to change or revise specifications and product design in connection with any feature of our

More information

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet Excel FWGH-L Merchandiser Data Sheet NSF Certified May 2016 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation)

More information

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount. with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready K E I P/N 0541253_J NSF Certified January 201 F L Warning: Terminal block NOT for case-to-case wire connection! J G I A

More information

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet EXCEL FWEGH-L Merchandiser Data Sheet P/N 0544871_F NSF Certifi ed March 2017 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National

More information

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount Freedom Line merchandisers are top mount refrigeration ready Freedom Line RFMN with INNOVATOR Doors NSF Certified January 18 OPTIONS SHOWN: Lighted Facades Warning: Terminal block NOT for case-to-case

More information

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet EXCEL FWEGH Merchandiser Data Sheet P/N 0544870_D NSF Certifi ed March 2017 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National

More information

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016 Technical Data Sheet NSF Certified October 2016 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the

More information

PWEE Technical Data Sheet

PWEE Technical Data Sheet Technical Data Sheet NSF Certified October 2016 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the

More information

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet Excel FWGH Merchandiser Data Sheet P/N 0540996_F NSF Certified January 2018 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National

More information

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount. Freedom Line RFMNS with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready H B F P/N 054156_J NSF Certified January 01 C I We reserve the right to change or revise specifications

More information

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017 Shown with Optional Light Bar Technical Data Sheet NSF Certified March 2017 Condensing Unit Control Panel We reserve the right to change or revise specifications and product design in connection with any

More information

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator)

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator) Low Temperature Frozen Food and Ice Cream Field Installed Dual Temp Operation E P Controlled (Evaporator Pressure egulator) GENEAL Model Dual Temperature Kit Application A dual temperature kit allows one

More information

Nosing Heater. Return Grill Heater

Nosing Heater. Return Grill Heater Insight standard field electrical connections are at the bottom of the merchandiser Insight IM1SL-L Merchandiser Data Sheet NSF Certifi ed September 2017 Fan* Defrost Heater (Below coil)* Coil* Nosing

More information

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases Installation & Service Manual JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases This manual has been designed to be used in conjunction

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual NFJGCX, NCJGCX, NTJGCX, NFMJGCX, NFJGECX, NCJGECX GLASS FRONT JUMBO ISLAND FROZEN FOOD/ICE CREAM/ MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display

More information

HGL- 1, 2 & 3 BS, TS Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers

HGL- 1, 2 & 3 BS, TS Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers HGL- 1, 2 & 3 S, TS ottom / Top Mount Low Temperature emote and Self Contained Glass Door Merchandisers HGL-2S HGL-3TS Installation & Operation Manual IMPOTANT Keep in store for future reference! P/N 0515296_D

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual NFJCX, NCJCX, NTJCX, JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases This manual has been designed to

More information

Mini-Combo id. Model MCH. Installation and Operation Instructions. Induced Draft Residential Gas-Fired Space/Water Heater

Mini-Combo id. Model MCH. Installation and Operation Instructions. Induced Draft Residential Gas-Fired Space/Water Heater Installation and Operation Instructions Document 2101B Installation and Operation Instructions for Mini-Combo id Model MCH Induced Draft esidential Gas-Fired Space/Water Heater Note: This document is to

More information

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases Installation & Service Manual THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General Installation & Service

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual N5D, N5DH, N5DL, N5DSC NARROW MULTI-DECK DAIRY/DELI MERCHANDISERS Medium Temperature Refrigerated Display Cases This manual has been designed to be used in conjunction with

More information

NFW, NCW, NFWG, NCWG, NFWE, NCWE

NFW, NCW, NFWG, NCWG, NFWE, NCWE Installation & Service Manual WIDE ISLAND FROZEN FOOD & ICE CREAM MERCHANDISERS Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General (UL/NSF)

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual NMFG Shown NMF / NMFG SINGLE DECK FROZEN MEAT MERCHANDISERS Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General

More information

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL FOR REACH-IN GLASS DOORS AND MULTI-DECK MERCHANDISERS INSTALLATION AND OPERATION MANUAL P/N 05055_A November 008 LED Dimmer Control Installation and Operation

More information

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases Installation & Service Manual L6FA MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General Installation &

More information

F-6 Multi-deck Frozen Food Wall Merchandisers

F-6 Multi-deck Frozen Food Wall Merchandisers F-6 Multi-deck Frozen Food Wall Merchandisers Installation & Service Manual Shipped With Case Data Sheets IMPORTANT Keep in store for future reference! P/N 0518253_B October 2013 English P/N 0518253 Spanish

More information

Reach-in Merchandisers

Reach-in Merchandisers Reach-in Merchandisers Medium and Low Temperature Use this manual along with door manual P/N 0425683 for cases with Innovator Doors Use this manual along with door manual P/N 3008521 for cases with EcoVision

More information

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA REFERENCE NOTES FOR ENGINEERING DATA "0.00" indicates that data is not available yet. Defrost heater 3-phase load is unbalanced. 3-Phase defrost heater data listed represent the maximum amps per phase.

More information

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL FOR REACH-IN GLASS DOORS AND MULTI-DECK MERCHANDISERS INSTALLATION AND OPERATION MANUAL P/N 05035_A December 008 LED Dimmer Control Installation and

More information

Installation Instructions

Installation Instructions HHK Series Installation Instructions Electric Heater Kits Installation in Standard and Variable Speed Indoor Air Handlers! IMPOTANT: The instructions included with this heater kit are for installations

More information

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference!

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference! Æ Low Temperature Single Deck Wall & Island Merchandisers Installation & Operation Manual Shipped with Merchandiser Data Sheets IMPORTANT Keep in store for future reference! MANUAL- I/O EXCEL LOW TEMP

More information

Electric Heat Accessory

Electric Heat Accessory Electric Heat Accessory AMFK05CHA AMFK05CHB AMFK07CHA AMFK07CHB AMFK0CHA AMFK0CHB AMFK4CHB AMFK20CHB AMFK25CHB AMFK30CHB Single Phase For Use ith Blower & Fan Coil Units and Electric Furnaces ANING Electrical

More information

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT ISF and ISM Low and Medium Temperature Remote and Self Contained Island Merchandisers IMPORTANT Keep in store for future reference! Installation & Service Manual P/N 0515154_B October 2010 P/N0515154B

More information

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French Kit P/N 3014447_A December 2016 OPTIONAL ANTI-CONDENSATE HEATER CONTROLLER FOR REACH-IN GLASS DOORS MANUAL- KIT INSTALLATION CONDENSATE HEATER Spanish 3014926 French 3014927 Door Heater Control P/N 3014447_A

More information

TO DO IF YOU SMELL GAS

TO DO IF YOU SMELL GAS Installation and Operation Instructions Document 8001D Installation and Operation Instructions for Mini-Combo II (Models MCT, MCS) esidential Gas-Fired Space/ater Heater NOTE: This manual is to be used

More information

Description/ Application

Description/ Application Form I-OPT-MH (2-16) Obsoletes Form I-OPT-MH (Version D.2) Installation of Multiple Heater Control, Options CL31 and CL32 Applies to: Models LDAP, UDAP, APD, UDAS, UDBP, UDBS, UEAS, F, B, V Description/

More information

MD Medium Temperature Self Contained Open Vertical Merchandisers

MD Medium Temperature Self Contained Open Vertical Merchandisers MD Medium Temperature Self Contained Open Vertical Merchandisers MD-14 MD-10 IMPORTANT Keep in store for future reference! Installation & Service Manual P/N 2402646_D February 2012 P/N2402646D P/N 2402646_D

More information

SQ3CD, SQ4CD, SQ5CD, SQ6CD, SQ8CD

SQ3CD, SQ4CD, SQ5CD, SQ6CD, SQ8CD E-1620 0509 SQ3CD, SQ4CD, SQ5CD, SQ6CD, SQ8CD Self-Contained & emote Models INSTALLATION & OPEATION INSTUCTIONS KEEP THIS MANUAL FO FUTUE EFEENCE Engineering and technical data are subject to change without

More information

BCH Medium Temperature Merchandisers

BCH Medium Temperature Merchandisers BCH Medium Temperature Merchandisers Models: BCH-8S and BCH-18 (1 Door) BCH-45 (2 Door) and BCH-68 (3 Door) Installation & Service Manual IMPORTANT Keep in store for future reference! P/N 2402474_F April

More information

Medium Temperature Bulk Produce and Bakery Merchandisers

Medium Temperature Bulk Produce and Bakery Merchandisers Medium Temperature Bulk Produce and Bakery Merchandisers Installation & Service Manual Shipped With Case Data Sheets IMPORTANT Keep in store for future reference! P/N 0518258_C October 2013 English P/N

More information

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference!

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference! Medium Temperature Meat, Delicatessen, Dairy and Produce Merchandisers Installation & Operation Manual Shipped With Case Data Sheets IMPORTANT Keep in store for future reference! MANUAL- I/O EXCEL MEDIUM

More information

FEDERAL INDUSTRIES IMSS60, IMSS84 & IMSS120 MODELS INSTALLATION & OPERATIONS MANUAL

FEDERAL INDUSTRIES IMSS60, IMSS84 & IMSS120 MODELS INSTALLATION & OPERATIONS MANUAL E3265 EV D 8/9/13 FEDEAL INDUSTIES IMSS60, IMSS84 & IMSS120 MODELS INSTALLATION & OPEATIONS MANUAL KEEP THIS MANUAL FO FUTUE EFEENCE Engineering and technical data are subject to change without notice.

More information

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for Medium Temperature Meat, Delicatessen, Dairy and Produce Merchandisers Installation & Operation Manual Shipped With Case Data Sheets IMPORTANT Keep in store for P/N 0463880_S Excel Series August 2018 future

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-AAX-0516A All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost

More information

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB H SSGB Technical Data Sheet P/N 3018921_E EPH Certified to NSF-7 January 2018 F A C D E A G B We reserve the right to change or revise specifications and product design in connection with any feature of

More information

RFLNS, RFMNS & RFLTM Freedom Line

RFLNS, RFMNS & RFLTM Freedom Line RFLNS, RFMNS & RFLTM Freedom Line Low or Medium Temperature Compressor Ready Tall or Narrow Footprint Reach-in Merchandisers IMPORTANT Keep in store for future reference! MANUAL- I/O FREEDOM REACH-IN Installation

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-AAX-1215A All-Temp 2 B LOW PROFILE UNIT COOLER Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk

More information

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES GENERAL Light controls - occupancy sensors are required Option 1: OEM Provided: OEM anti-condensate and lighting controls (on/off) are standard unless otherwise specified. Option 2: End User Provided:

More information

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax: SMAT ZONE TM VAV Electronic Diffusers SMAT ZONETM www.smartdiffuser.com SMAT ZONE SE-HC/M, Type LT, Lay-in, T-Bar, VAV Fully Modulating Diffuser Specifications APPLICATION: The Model SE-HC/M VAV Smart

More information

MD Medium Temperature Self Contained Open Vertical Merchandisers

MD Medium Temperature Self Contained Open Vertical Merchandisers MD Medium Temperature Self Contained Open Vertical Merchandisers MD-14 MD-10 Installation & Service Manual IMPORTANT Keep in store for future reference! MANUAL - I/O SELF CONTAINED MD P/N 2402646_E December

More information

HIGH-EFFICIENCY CONDENSING UNITS

HIGH-EFFICIENCY CONDENSING UNITS HIGH-EFFICIENCY CONDENSING UNITS FOM NO. ATZ-194 EV. 2 Supersedes Form No. ATZ-194 ev. 1 Featuring Industry Standard -410A efrigerant TZAL- HIGH EFFICIENCY 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE

More information

SERIES NIM. Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT

SERIES NIM. Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT SERIES NIM Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT Hussmann Monterrey, Mexico Carretera Mexico-Laredo KM. 1009 Cienga de Flores, Nuevo Leon 65550 Mexico Phone: (52)

More information

Parallel Rack Systems

Parallel Rack Systems Parallel Rack Systems Installation & Service Manual IMPORTANT Keep in store for future reference! P/N 0427598_B July 2013 P/N 0427598_B iii TABLE OF CONTENTS INSTALLATION Shipping Damage....................

More information

HGM-1, 2 & 3 BS, TS Bottom / Top Mount Medium Temperature Remote and Self Contained

HGM-1, 2 & 3 BS, TS Bottom / Top Mount Medium Temperature Remote and Self Contained HGM-1, 2 & 3 BS, TS Bottom / Top Mount Medium Temperature emote and Self Contained Glass Door Merchandisers HGM-3BS HGM-2TS Installation & Operation Manual IMPOTANT Keep in store for future reference!

More information

N5FGA, N5NGA, N5FGNA, N5NGNA

N5FGA, N5NGA, N5FGNA, N5NGNA Installation & Service Manual N5FGA, N5NGA, GLASS DOOR MERCHANDISERS (ARDCO) Frozen Food & Medium Temp Cases With Reversible Doors This manual has been designed to be used in conjunction with the General

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Stackable Crescent Cuber Models KM-1800SAH/3 KM-1800SWH/3 KM-1800SRH/3 A Superior Degree of Reliability SERVICE MANUAL www.hoshizaki.com Number: 73131 Issued: 11-11-2005 Revised:

More information

IOM 410. Installation Operation Maintenance Information. UNIT COOLERS Super-Flo (SD Models) Easy-Flo (EF Models) Table of Contents

IOM 410. Installation Operation Maintenance Information. UNIT COOLERS Super-Flo (SD Models) Easy-Flo (EF Models) Table of Contents IOM 410 Installation Operation Maintenance Information UNIT COOLERS Super-Flo (SD Models) Easy-Flo (EF Models) Air, Electric & Hot Gas Defrost Table of Contents Inspection..........................................

More information

Service Merchandisers

Service Merchandisers Service Merchandisers Fresh Meat, Delicatessen, and Seafood Merchandisers (Includes Wedge Installation) NSF Certified Installation & Operation Manual Shipped With Case Data Sheets IMPORTANT Keep in store

More information

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit HCD/HMD/HCF/HMF1010R HCD/HMD/HCF/HMF1410R Order parts online www.follettice.com Drop-in Remote Condensing RIDE remote ice

More information

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit HCD/HMD/HCF/HMF1010R HCD/HMD/HCF/HMF1410R Order parts online www.follettice.com Drop-in Remote Condensing RIDE remote ice

More information

Installation and Operation Manual

Installation and Operation Manual series Installation and Operation Manual FGCEID GLASS DOOR REACH-IN This refrigerator conforms to the Commercial Refrigerator Manufacturers Association s Health and Sanitation Standard. series Page 2 INSTALLATION

More information

Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers

Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers Merchandisers Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers IMPORTANT Keep in store for future reference! Installation & Service Manual Shipped With Merchandiser

More information

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker. 73105 IMPORTANT Only qualified service technicians should attempt to service or maintain this icemaker. No service or maintenance should be undertaken until the technician has thoroughly read this Service

More information

Field Top Mounted Condensing Unit

Field Top Mounted Condensing Unit Field Top Mounted Condensing Unit INSTALLATION & OPERATIONS MANUAL RF/RF-N, RM/RM-N IMPORTANT Keep in store for future reference! REVISION HISTORY VERSION 1.0 New manual This manual is specific to the

More information

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy Upgrade Installation Manual MANUAL- KIT INSTALLATION ECOSHINE II MULTI-DECK P/N 0524791_G October 2016 Spanish 0527937 French

More information

PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY

PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY Tech Sheet Do not discard AIG Electrical Shock Hazard Disconnect power before servicing. eplace all parts and panels before operating. Failure to do so can result in death or electrical shock. PECAUTIOS

More information

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature

More information

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual GSVM Medium Temperature Self Contained Open Vertical Merchandisers IMPORTANT Keep in store for future reference! Installation & Service Manual P/N 0515275_F July 2013 P/N 0515275_F iii IMPORTANT KEEP

More information

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons ACNF Series Ceiling-Mounted Air Handlers 1½ to 2½ Tons Contents Nomenclature...2 Heat Kit Data...2 Product Specifications...3 Dimensions...5 Airflow Data...5 Wiring Diagram...6 Accessories...8 Features

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual N7DNHPL, NHDHPL, NHDHPM HIGH PERFORMANCE EXT. HEIGHT MULTI-SHELF MERCHANDISER Medium Temperature Self Serve Display Cases This manual has been designed to be used in conjunction

More information

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls Merchandisers Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls IMPORTANT Keep in store for future reference! Installation Operation

More information

Service Merchandisers

Service Merchandisers Service Merchandisers Fresh Meat, Delicatessen, and Seafood Merchandisers (Includes Wedge Installation) NSF Certified Installation & Operation Manual Shipped with Technical Data Sheets IMPORTANT Keep in

More information