Unabhängige, beratende und planende Ingenieure für Wasser-, Abwasser-, Abfall- und Umwelttechnik

Size: px
Start display at page:

Download "Unabhängige, beratende und planende Ingenieure für Wasser-, Abwasser-, Abfall- und Umwelttechnik"

Transcription

1 An Element for Your Success Independent consultants and planning engineers for water, waste water, solid waste and environmental technologies Unabhängige, beratende und planende Ingenieure für Wasser-, Abwasser-, Abfall- und Umwelttechnik

2 COD Determination

3 Measurement Method: Quick COD (LAR) Thermal combustion at 1200 C which guarantees the complete oxidation of the sample without reagents. Then measured with an NDIR detector Reliability: High reliability 98% availability Sensitivity: Measurement range: mg/l COD 100-2,000 mg/l COD 500-5,000 mg/l COD 1,000-8,000 mg/l COD 20, ,000 mg/l COD More ranges on request

4 Calibration: Quick COD (LAR) Performance: Feautures and accessories: Catalyst-free technique Reagent-free analysis No filtration necessary No memory effects Very low maintenance and operational costs Auto start option Analyser available minimum 98% Multi stream measurement (optional) Monitors up to six streams

5 Equipment Configuration: Quick COD (LAR) Designed for wall mounting, outdoors or indoors. Rail- and stand-mounting options are available. weatherproof, and lockable. Dimensions Width 700 x height 1,020 x depth 520 mm Weight 115 kg (standard) Sample Volume: microliter small Sample Preparation Maintenance- free particle cutter Optional homogeniser for the continuous homogenisation of samples

6 Response Time: 1-2 minutes Quick COD (LAR) Particle Tolerance: Max. 0.8mm according to ISO 8245 Measurement interval 1 3 minutes - depending on the application Reagent Consumption Only distilled water and a small amount of inexpensive acid required Reagent consumption: No reagent

7 CAA- Continuous Auto Analyzer (PAI) Measurement Method: Real continuous automatic monitoring of a wide range of parameters in liquid sample using these analytical techniques: Potentiometry Conductivity Photometry Fluorimetry Reliability: Sensitivity: not specified. Calibration Manual/automatic (optional)

8 CAA- Continuous Auto Analyzer (PAI) Performance: Feautures and accessories: Accessories Special features Contrary to other techniques which analyze different samples, analyse the same sample continuously. Cacluation of contaminant loads even if rapid changes in concentration may occur. Sample Condition: Pressure: 0 bar with sample pump. Higher pressures on demand Flow rate: application dependant Temperature: >0-50 º C (application dependant)

9 CAA- Continuous Auto Analyzer (PAI) Equipment configuration: Layout of CAA for ethylone oyide in glycol/water mixtures

10 CAA- Continuous Auto Analyzer (PAI) Dimensions: Housing: wall mounting, stainless steel and plastic Width ±400 mm x depth: 270 mm x heigt: 910 mm Weight: approximately 30 kg Information transfer: Transmitting results to process control an analog output ( (0)4-20 ma) is used. Equipment safety: Two separated housings to protect the electronics from any hazardous vapour and liquids.

11 CAA- Continuous Auto Analyzer (PAI) Operation : Inbuilt toch screen for manual control of CAA analyser. Results are displayed in numerical or graphical presentation Operation Notification and Failure: System fault: in case of system failure the alarm contact is triggered. Threshold alarm (optional): relays for threshold alarm are available. Response Time: Particle Tolerance: Measurement interval continuous

12 Measurement Method: Liquiline System CA 80 (EH) Established COD dichromate method directly comparable to laboratory results. Reliability: ± 10 % according to potassium hydrogen phthalate test Sensitivity: 10-5,000 mg/l COD 40-20,000 mg/l COD Calibration Automatic calibration and cleaning User-configurable measuring, cleaning and calibration intervals Zero standard: 500 ml per month given a calibration interval of 48 h. (no dilution module) Standard 1: approx. 90 ml per month given a calibration interval of 48 h (no dilution module)

13 Liquiline System CA 80 (EH) Calibration Interval: 1 h to 90 days, depending on the application and ambient condition Performance: Features and accessories: Accessories Kit CA8x/CAT860: wall mounting Kit CA8x/CAT860: housing bottom Kit CA8x: door with window Sample Characteristics: Volume: 8 ml per measurement Temperature: 4 to 40 C (39 to 104 F) Consistency: Low solids content, aqueous, homogenized Measuring interval: Continuous (approx. 55 min), adjustable 30 min to 24 h

14 Liquiline System CA 80 (EH) Equipment Safety: Electrical safety According to EN/IEC :2010, Class I equipment Low voltage: overvoltage category II For installations up to 2000 m (6500 ft) above MSL Information Transfer: Particle Tolerance: Detection Limit: Ambient temperature range 5 to 40 C (41 to 104 F) Humidity 10 to 95%, not condensing

15 Comparison LAR PAI EH Reliability Sensitivity Performance

Series 9000 Total Hydrocarbon Analyzer

Series 9000 Total Hydrocarbon Analyzer Series 9000 Total Hydrocarbon Analyzer Analyzer The Baseline Series 9000 is the candidate of choice whenever accurate, reliable total hydrocarbon analysis is required. The Series 9000 analyzer provides

More information

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001 ISO-14001 ISO-9001 SPECIFICATION SHEET ORGANIC POLLUTION MONITOR Model: OPM-410A The Model OPM-410A monitors organic pollution in water from industrial effluent, rivers etc.. The design and construction

More information

Mercury Vapor Monitor VM-3000

Mercury Vapor Monitor VM-3000 Member of the envea Group Mercury Vapor Monitor VM-3000 Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Proven reliable detection method: UV absorption (CVAAS)

More information

Certificate: / 29 April 2014

Certificate: / 29 April 2014 Test report: 936/21217455/A of 10 September 2013 Initial certification: 01 April 2014 Expiry date: 31 March 2019 Publication: BAnz AT 01 April 2014 B12, chapter I, No. 1.1 Approved application The tested

More information

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en Technical information TI074R/09/en 51001353 Contactor RTA421 Contactor with loop power supply for monitoring currentorvoltagesignals Application areas Plant and machine construction Panel builders Process

More information

HFID Heated Total Hydrocarbon Analyzer Module

HFID Heated Total Hydrocarbon Analyzer Module Product Data Sheet PDS 103-685.A01 October, 2003 NGA 2000 HFID Heated Total Hydrocarbon Analyzer Module Heated analyzer designed to operate from 200 F to 400 F Eliminates loss of hydrocarbons due to condensation

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

Process Alarm Module RTA 421

Process Alarm Module RTA 421 Technical Information TI 074R/24/ae Process Alarm Module RTA 421 Alarm module and power supply for monitoring current or voltage signals Application Areas Plant and machine construction Panel builders

More information

VM-3000 Mercury Vapor Monitor

VM-3000 Mercury Vapor Monitor MERCURY INSTRUMENTS Analytical Technologies VM-3000 Mercury Vapor Monitor Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Proven reliable detection method: UV absorption

More information

Certificate: _01 / 22 March 2013

Certificate: _01 / 22 March 2013 Test report: 936/21219384/A of 27 September 2012 Initial certification: 20 July 2012 Expiry date: 19 July 2017 Publication: BAnz AT 05 March 2013 B10, chapter I, No. 1.6 Approved application The tested

More information

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number Worldwide Supplier of Safety Solutions GfG Instrumentation 1194 Oak Valley Drive #20 Phone: 734-769-0573 Fax: 734-769-1888 E-Mail: info@gfg-inc.com Internet: www.gfg-inc.com GMA 301 Operation Manual Part

More information

VM-3000 Mercury Vapor Monitor

VM-3000 Mercury Vapor Monitor MERCURY INSTRUMENTS ANALYTICAL TECHNOLOGIES VM-3000 Mercury Vapor Monitor Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Portable, integrated battery for 6 hours

More information

Automation System TROVIS 5400 Boiler Controller TROVIS 5474

Automation System TROVIS 5400 Boiler Controller TROVIS 5474 Automation System TROVIS 5400 Boiler Controller TROVIS 5474 Application Weather-sensitive control of up to two boilers, designed for single-stage, two-stage or also modulating operating mode. Communication

More information

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring. Water Quality Labo- Soil/ Soil/ Sedi- Sam- & Air / Dust Toxic gases are present in a wide variety of industrial and civil installations and their detection and monitoring is crucial for the safe working

More information

COMPLETELY AUTOMATED HYDROLYSIS

COMPLETELY AUTOMATED HYDROLYSIS HYDROTHERM for classic fat determination according to Weibull-Stoldt COMPLETELY AUTOMATED HYDROLYSIS EFFICIENT SAFE VALID FLEXIBLE CONVENIENT Up to 80 % cost savings per sample Process runs in closed system

More information

Toxic Gas Detection. Model F12. Toxic Gas Detection

Toxic Gas Detection. Model F12. Toxic Gas Detection Toxic Gas Detection Model F12 Toxic Gas Detection Smart Sensor Technology The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of our explosion-proof D12 transmitter. In its standard form,

More information

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications SAFETY MANUAL Intelligent Sensors for H 2 S Gas Applications The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically

More information

Data Sheet. >>AMTAX inter 2

Data Sheet. >>AMTAX inter 2 Data Sheet DOC053.52.03086.NOV02 - Subject to change without notice >>AMTAX inter 2 Ammonium Process Photometer 1 Technical data 1. Technical data Measuring technique: Indophenol blue method, derived from

More information

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM User Instructions For The Model 5200 Gas Monitor System To completely customize the specifications to your exact application, modifications to the following

More information

Dedicated Analytical Solutions. The Complete Chemical Analysis Collection

Dedicated Analytical Solutions. The Complete Chemical Analysis Collection Dedicated Analytical Solutions The Complete Chemical Analysis Collection Sample Preparation Good results start with sample preparation. Instrument errors are very small compared to the errors associated

More information

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460) Operating Manual TS400 Test Station for Microtector II Series (G450/G460) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)2 31 / 5 64 00 0 FAX +49 / (0)2 31 /

More information

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability GasSens Modular Gas Detector... Self Checking Gas Sensors GasSens is a flexible component system providing a variety of options to meet individual gas detection and alarm requirements. From chemical and

More information

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER ISO-14001 ISO-9001 SPECIFICATION SHEET SILICA ANALYZER Model: SLC-1605 (for very low concentration) SLC-1615 (for low concentration) SLC-1625 (for high concentration) This equipment is used for high accuracy

More information

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! USER GUIDE English IMPORTANT PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal. Contents

More information

MICROpeL 75 Combustible Gas Sensor Part Number: PM

MICROpeL 75 Combustible Gas Sensor Part Number: PM MICROpeL 75 Combustible Gas Sensor Part Number: PM759-000 Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance Reduced

More information

SECTION Fluorescent Dissolved Oxygen Measuring System

SECTION Fluorescent Dissolved Oxygen Measuring System SECTION 40 75 43 Fluorescent Dissolved Oxygen Measuring System PART 1 General 1.01 SUMMARY A. Requirements for a high-performance, digital fluorescence sensor for measurement of dissolved oxygen in liquid.

More information

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display. Sheet No. 1 of 4 monitor/analyzer with alarm and Graphical Display. Sheet No. 2 of 4 It specially designed to analyze any gas of your choice, its automatic operation, accurate measurement and crystal clear

More information

Certificate: _01 / 22 March 2013

Certificate: _01 / 22 March 2013 Test report: 936/21219384/B of 27 September 2012 Initial certification: 20 July 2012 Expiry date: 19 July 2017 Publication: BAnz AT 05 March 2013 B10, chapter I, No. 1.5 Approved application The tested

More information

Certificate: / 9 February 2011

Certificate: / 9 February 2011 Test report: 936/21212470/A of 1 October 2010 First certification: 26 January 2011 Run of validity until: 25 January 2016 Publication BAnz. 26 January 2011, No. 14, p. 294, Chapter I No. 1.1 Approved application

More information

AQUACON. Chief characteristic for realizing this product family was:

AQUACON. Chief characteristic for realizing this product family was: Process analyses with AQUACON -type tested analyzers Chief characteristic for realizing this product family was: best cost-benefit relationship, simple operation, adjustable nominal value, adjustable tracing

More information

SECTION Free/Available Chlorine Analysis System

SECTION Free/Available Chlorine Analysis System SECTION 40 75 21 Free/Available Chlorine Analysis System PART 1 General 1.01 SUMMARY A. Requirements for a digital sensor system for free chlorine measurement for disinfection purposes in drinking water,

More information

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0) DESIGN MANUAL MODEL GIR910 INFRARED CARBON DIOXIDE (CO 2 ) GAS SENSOR 70091 The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0) The information and

More information

Operations Manual GMA 313 CO 2. Gas Monitor for one detection point

Operations Manual GMA 313 CO 2. Gas Monitor for one detection point GMA 313 CO 2 Gas Monitor for one detection point Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.gfg-inc.com GfG Products for Increased Safety Congratulations

More information

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics 4000TOC Sensor THORNTON Leading Pure Water Analytics 4000TOC Sensor Fast, continuous measurements No reagents or chemicals needed No moving parts Meets USP 643, 645,Ch P, EP 2.2.44, and JP requirements

More information

FUNCTIONAL SAFETY MANUAL

FUNCTIONAL SAFETY MANUAL FUNCTIONAL SAFETY MANUAL UltraSonic EX-5 Ultrasonic Gas Leak Detector The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent

More information

Stand Alone DYNAGARD SP Operation Manual

Stand Alone DYNAGARD SP Operation Manual Stand Alone DYNAGARD SP Operation Manual Contents Page General Description 1 Detection Principle 1 For Your Safety 1 Design 2 Mounting 2 Mounting Position of DYNAGARD SP 2 Installation of Electrical Connections

More information

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2 FEATURES: Closed Loop Design (Class A Wiring) Microprocessor Based System Intelligent Distributed System Structure Quick Response Time Fire Alarm in

More information

Model Q45P/R. ph/orp Monitor...

Model Q45P/R. ph/orp Monitor... Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.

More information

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000 brochure On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000 Advanced Sensors Ltd Oil in Water Analyser System known as the OIW-EX100 or OIW-EX 1000. The system is designed to monitor

More information

Silica, Phosphate, Hydrazine Analyzers Series 2140 Specifications

Silica, Phosphate, Hydrazine Analyzers Series 2140 Specifications Silica, Phosphate, Hydrazine Analyzers Series 2140 Specifications 70-82-03-62 September 2009 Introduction REVOLUTIONARY PATENTED TECHNOLOGY Our Colorimetric Analyzers are based on the new patented Loop

More information

Datalogging as standard

Datalogging as standard Datalogging as standard for expanded performance Autofim II and Autofim II GC have a sophisticated datalogging system, as standard, which enables you to keep a permanent data record. The memory is capable

More information

Model Q45P/R. ph/orp Monitor...

Model Q45P/R. ph/orp Monitor... Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.

More information

International comparison of validation methods for dust concentration measurement

International comparison of validation methods for dust concentration measurement International comparison of validation methods for dust concentration measurement Validation of dust monitors can be divided into 2 steps: 1. Validation of a generic dust monitor as an instrument (Type

More information

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System. Product Guide Specification Nexus Integrated Burner Control System 1. General 1.1 Overview Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning

More information

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES Generalities HPLC - PELTIER COLUMN-THERMOSTATS GENERALITIES This manual has been updated to the actual standard. It now covers all the features of the actual Jetstream series models. All rights concerning

More information

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly Operation Manual GMA200-MT Gas detection controller for mounting rail assembly GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)231 / 564 00 0 FAX +49 / (0)231

More information

Betriebsanleitung / Operation manual. Druckwächtereinheit QUINGUARD / Pressurization Controller QUINGUARD

Betriebsanleitung / Operation manual. Druckwächtereinheit QUINGUARD / Pressurization Controller QUINGUARD Betriebsanleitung / Operation manual Druckwächtereinheit QUINGUARD / Pressurization Controller QUINGUARD 12 V Version 07/2014 Manufacturer... 28 Description... 28 Installation of the QUINGUARD unit...

More information

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex Part 2 Direct Reading Instrumentation Direct Reading Instruments Many different instruments Many different operating principles including: Electrochemical Photoionisation Flame ionisation Chemiluminescence

More information

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR The EMS510 provides continuous, low maintenance, precision measurement of Opacity and Dust (mg/m3). It is designed for monitoring visible smoke in the exhaust

More information

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

4P75 CiTipeL Combustible Gas Sensor Part Number: PM Product Datasheet 4P75 Document Purpose The purpose of this document is to present the performance specification of the 4P75 CiTipeL. This document should be used in conjunction with Operating Principles

More information

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features: Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low cost package. Patented

More information

EC 160 CO 2. Incubator

EC 160 CO 2. Incubator EC 160 Incubator EC 160 Incubator OPTIMIZED CULTURE CONDITIONS Reproducible and reliable cell growth is dependent upon three critical parameters, temperature, concentration and relative humidity. EC 160

More information

Frequently Asked Questions

Frequently Asked Questions 1. 2. What advantages does the GT3000 have over the C7064? Hot swappable GTS sensor module is intrinsically safe and allows live maintenance under power Supports HART communication Supports local, one-person

More information

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases DESCRIPTION Gas measuring and monitoring controller based on stateof-the-art microtechnology with integrated sensor for continuous monitoring

More information

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance 4P-90 CiTipeL Combustible Gas Sensor Part Number: PM143-000 Performance

More information

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.

More information

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering. System Overview F300K Compact Flame Scanner Sensors and systems for combustion engineering www.lamtec.de LAMTEC F300K Compact Flame Scanner Approvals. 0085 Gas Appliances Directive 2009/142/EC, CE0085

More information

portable gas analyser

portable gas analyser www..com portable gas analyser Professional flue gas analyser that combines high quality of sample conditioning with great measurement accuracy. The device is contained in a compact soft casing. Analyser

More information

portable gas analyser

portable gas analyser www..com portable gas analyser The largest of s analysers equipped with electrochemical cells. It can fit even up to 7 EC cells and up to 3 sensors. GA-60 has a large (320*240), graphical LCD with backlighting.

More information

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head 4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.

More information

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual Parameter Method ####, Operation & Maintenance Manual Rev 3/26/2018 Contact Information Document Information Customer Name: Plant Name/Location: Date: Analyzer Serial #: ASA, Inc. (Applied Spectrometry

More information

PHOENIXL 300 New Standards in Leak Testing. Technical information

PHOENIXL 300 New Standards in Leak Testing. Technical information PHOENIXL 300 New Standards in Leak Testing Technical information 180.75.01 PHOENIXL 300 Helium Leak Detector A Helium Leak Detector of the Premium Class The new helium leak detector PHOENIXL300 from Oerlikon

More information

intrinsically safe detector for hydrocarbon gases

intrinsically safe detector for hydrocarbon gases portable flame ionisation detector intrinsically safe detector for hydrocarbon gases Intrinsically safe detector for hydrocarbon gases Monitoring gases in confined and potentially explosive situations

More information

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector FUNCTIONAL SAFETY MANUAL Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector The information and technical data disclosed in this document may be used and disseminated only for the purposes

More information

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options. All icon products are Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options. Certified to global standards: ATEX, IECEx, TIIS, EAC-EX, ETL approved

More information

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440) Safety Temperature Limiter STL 50 Certified to DIN EN 14597 (replaces DIN 3440) Features M For use as: STB Protection - temperature limiter ASTB Exhaust gas - protection - temperature limiter STW Protection

More information

FMEDA Report. Failure Modes, Effects and Diagnostic Analysis. KFD0-CS-Ex*.54* and KFD0-CS-Ex*.56* Project: X7300

FMEDA Report. Failure Modes, Effects and Diagnostic Analysis. KFD0-CS-Ex*.54* and KFD0-CS-Ex*.56* Project: X7300 Failure Modes, Effects and Diagnostic Analysis Device Designation: KFD0-CS-Ex*.54* and KFD0-CS-Ex*.56* Project: X7300 Pepperl+Fuchs GmbH Mannheim Germany Mannheim norm sheet 1 of 16 Released EDM checkout

More information

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range The BINDER MKFT series environmental simulation chamber for low temperature

More information

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen PolyGard Single Point Controller SPC-X3-XX for Toxic Gases and Oxygen DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor and

More information

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1) ATÜVRheinland Precisely F=ight. CERTIFICATE of Product Conformity (QAL1) Certificate No.: 0000036943 02 Certified AMS: Manufacturer: Test lnstitute: DUSTHUNTER SB100 for dust SICK Engineering GmbH Bergener

More information

GMA 36 Pro. Operation Manual. Stand Alone Monitor

GMA 36 Pro. Operation Manual. Stand Alone Monitor Operation Manual GMA 36 Pro Stand Alone Monitor GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 D-44143 DORTMUND TELEPHONE +49 / (0) 2 31 / 5 64 00 0 FAX +49 / (0) 2 31 / 51 63 13 INFO@GFG-MBH.COM

More information

CLARITY II TURBIDIMETER

CLARITY II TURBIDIMETER Product Data Sheet PDS 71-T1055/rev.J January 2006 Model T1055 CLARITY II TURBIDIMETER COMPLETE SYSTEM includes single or dual input analyzer, sensor(s), and debubbler assembly CHOOSE U.S. EPA METHOD 180.1

More information

GPR-2600 Oxygen Analyzer

GPR-2600 Oxygen Analyzer Technical Specifications * Accuracy: Analysis: Application: Approvals: < 2% of FS range under constant conditions 0-1%, 0-5%, 0-10%, 0-25% FS ranges Auto-ranging or manual lock on a single range Oxygen

More information

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System SAFETY MANUAL Open Path Hydrocarbon Gas Monitoring System The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically

More information

GMA 36 Pro. Operation Manual. Stand Alone Monitor

GMA 36 Pro. Operation Manual. Stand Alone Monitor Operation Manual GMA 36 Pro Stand Alone Monitor GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 D-44143 DORTMUND TELEPHONE +49 / (0) 2 31 / 5 64 00 0 FAX +49 / (0) 2 31 / 51 63 13 INFO@GFG-MBHCOM WWWGASDETECTIONBIZ

More information

PUV, PIR and PFO Series BROCHURE

PUV, PIR and PFO Series BROCHURE PUV, PIR and PFO Series BROCHURE JUNHO 2013 ABB Multiwave TM process photometers PUV3402, PIR3502 and PFO3372 Measure vapor and liquid samples in IR, NIR, UV and VIS regions Process photometers PUV3402,

More information

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies. GE Sensing & Inspection Technologies Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in

More information

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies. GE Sensing & Inspection Technologies Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in

More information

Free Chlorine Measuring System

Free Chlorine Measuring System Product Data Sheet PDS 71-FCL/rev.H September 2008 Model FCL Free Chlorine Measuring System COMPLETE SYSTEM INCLUDES sensor, connecting cable, analyzer, and flow controller. CONTINUOUS ph CORRECTION eliminates

More information

Rosemount Analytical Solutions. Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze

Rosemount Analytical Solutions. Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze Rosemount Analytical Solutions Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze Innovation applied to Offshore Applications Well head analysis Process

More information

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting Operation Manual GMA200-MW16 Gas detection controller for wall mounting GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, GERMANY TEL. +49 / (0)231 / 564 00 0 FAX +49 / (0)231 / 516 313

More information

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

SAFETY MANUAL. Multispectrum IR Flame Detector X3301 SAFETY MANUAL Multispectrum IR Flame Detector X3301 SAFETY-CERTIFIED MODEL X3301 MULTISPECTRUM INFRARED DETECTOR This manual addresses the specific requirements and recommendations applicable to the proper

More information

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD Dew Point Mirror 373 High Precision Fast Response Wide Measuring Range Laboratory Reference Touch Screen Full Color High Resolution LCD Chilled Mirror Hygrometry Chilled mirror hygrometry, a process used

More information

II 1G EEx ia IIC T4 T a = -20ºC to +60ºC

II 1G EEx ia IIC T4 T a = -20ºC to +60ºC Microview Compact ATEX Hygrometer II 1G EEx ia IIC T4 T a = -20ºC to +60ºC MCM s ATEX On-Line Hygrometer Redefines Hazardous Area Applications! Continuous on-line analysis or incorporate the Microview

More information

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection Procedure No: SOP-020 Revision No: 1.0 (January 21, 2011) Page No.: 1 of 7 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting, and to

More information

LFL Monitoring. MEGTEC Systems

LFL Monitoring. MEGTEC Systems LFL Monitoring MEGTEC Systems Flammability For each volatile flammable substance there is a concentration in air (usually expressed as % of volume, known as Lower Flammable Limit LFL). Below LFL concentration

More information

Gas cooler series TC-Standard+

Gas cooler series TC-Standard+ Gas Analysis Gas cooler series In emission measurement, process control relies on prompt and exact determination of the operating parameters. Here, gas analysis is the key for safe and efficient control

More information

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1 Project Name Page 1 PART 1 GENERAL 1.1 Section includes: A. Phosphate process analyzer for semi - continuous monitoring of phosphate in water. 1.2 Measurement Procedures The phosphate analyzer shall be

More information

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Carbon Monoxide (CO) Gas Detector March 15 GCO 300 GCO Carbon Monoxide (CO) Gas Detector March 15 Features Output 4-20 ma or 2-10 Vdc Power supply 24 Vdc Ranges 0-100 ppm or 0-300 ppm IP65 enclosure with quick locking screws Digital measurement value processing

More information

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance IR4000 Point Infrared Combustible Gas Detection System The Reliable and Flexible Safety Solution That s Low Maintenance Multi-Point Gas Detection That s Fast Set-Up, Low Maintenance, Cost-Effective The

More information

Datasheet: K-22 LO Sensor

Datasheet: K-22 LO Sensor Datasheet: K-22 LO Sensor The K- 22 LO is a CO2 sensor module designed to be built- in into stationary ventilation equipment, such as window vent or duct exhaust actuators, serving as a linear transmitter

More information

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection. FIXED GAS DETECTION OLCT 700 Series OLCT 700/710 industrial gas detection sensors are a new generation of intelligent sensor modules that incorporate and integrate several leading edge improvements. &

More information

Complete Gas Analysis

Complete Gas Analysis Complete Gas Analysis A complete range of gas analysers, systems and accessories for emissions, air quality, research and process monitoring. The Signal Group, incorporating the gas analysis business of

More information

Gas Controller Module GC-06

Gas Controller Module GC-06 Page 1 Oct. 2015/2 Measuring, warning and controlling module for toxic, combustible and refrigerant gases and vapours. The gas controller series GC-06 is designed in accordance with the standard EN 50545-1.

More information

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301 Refrigeration and Air Conditioning Technical leaflet Electronic controller EKC 201 and EKC 301 RC.5L.A1.02 RC.5L.A2.02 09-1998 Introduction EKC 201 and 301 are used for temperature control compressor control

More information

PG 990 Atomic Absorption

PG 990 Atomic Absorption PG 990 Atomic Absorption Features Fully Automated Spectrophotometer The flame and graphite furnace is integrated into one instrument. The change over from one technique to another is carried out by simple

More information

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version Fire Alarm Systems FAP-420/FAH-420 Automatic Fire Detectors LSN improved version FAP-420/FAH-420 Automatic Fire Detectors LSN improved version ombination of optical, thermal and chemical sensors with intelligent

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket

More information

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist