RESULT SHEET. Controls and Distribution Systems. The Fire extinguisher activator, brand FirePro Systems, type Activator meets the EMC requirements of:

Size: px
Start display at page:

Download "RESULT SHEET. Controls and Distribution Systems. The Fire extinguisher activator, brand FirePro Systems, type Activator meets the EMC requirements of:"

Transcription

1

2 Report Number: EMC1 EMC Report Page: RS 1/17 TEST HOUSE: TESTING DEPT.: KIWA CERTIFICATION BV Controls and Distribution Systems Conclusion: The Fire extinguisher activator, brand FirePro Systems, type Activator meets the EMC requirements of: EN Electromagnetic compatibility (EMC)- Part 6-1: Generic standards- Immunity for residential environments (2007) EN Electromagnetic compatibility (EMC)- Part 6-3: Generic standards- Emission standard for residential environments (2007) The immunity requirements of EN are fulfilled and the emission is in compliance with EN

3 Report Number: EMC1 EMC Report Page: RS 2/17 Contents: 1. INTRODUCTION Applied standards IDENTIFICATION OF EQUIPMENT UNDER TEST (EUT) General description of EUT: Identification: Description of ports: Operating mode(s): Reference documents: Environmental conditions: IMMUNITY TESTING Test set-up Immunity to voltage surges Immunity to electrical fast transients/burst (EFT) Immunity to conducted disturbances Immunity to radiated electromagnetic disturbances Immunity to electrostatic discharges EMISSION MEASUREMENTS Radiated disturbances (30 MHz 1000 MHz) Conducted continuous disturbances ( MHz)...16

4 Report Number: EMC1 EMC Report Page: RS 3/17 1. Introduction The electromagnetic compatibility of the Fire extinguisher Activator, brand FirePro Systems, type Activator has been tested in accordance with the standards mentioned in clause 1.1. For the remainder of this report the Fire extinguisher Activator will be referred to as EUT (Equipment Under Test). The EUT was tested in the time period: Applied standards Immunity behaviour: Immunity testing has been performed according to the following standard: EN voltage dips and interruptions with performance criterion B/C - surges with performance criterion B - fast transients with performance criterion B - injected currents up to 80 MHz with performance criterion A - radiated electromagnetic disturbances with performance criterion A - electrostatic discharge with performance criterion B Emission testing: Emission measurements have been performed according to the following standard: EN

5 Report Number: EMC1 EMC Report Page: RS 4/17 2. Identification of equipment under test (EUT) 2.1 General description of EUT: Fire extinguisher activator 2.2 Identification: Equipment under test : Fire extinguisher activator Manufacturer : FirePro Systems Brand name : FirePro Systems Type : Activator Receipt date : Test date(s) : Description of ports: Enclosure port: The enclosure is mainly made of steel Cables subjected to the tests: supply cable 2.4 Operating mode(s): Standby position 2.5 Reference documents: none 2.6 Environmental conditions: Temperature: 23 +/- 2 degrees Celsius Note: Photos of the EUT are included in KIWA Certification B.V. files only.

6 Report Number: EMC1 EMC Report Page: RS 5/17 3. Immunity testing Utilised test equipment and methods in accordance with: CISPR 16 EN EN EN EN EN EN EN Test set-up The EUT is placed in the position in which it is normally operated.. The status of the following parameters of the EUT will be monitored: Operating status of the EUT by using a TV-camera. 3.2 Immunity to voltage surges - Test performed in accordance with EN Severity levels and performance criteria in accordance with EN , clause 8 - KIWA test procedure: WV_EU_EM.TISU: General procedure for testing the immunity behaviour of electrical and electronic appliances, systems and installations to surges - Measurement uncertainty: Parameter: Test level range: Level uncertainty: Voltage amplitude (open circuit) 500V 2 kv +/- 12 % Voltage front time (open circuit) 1.2 μs +/- 35 % Voltage half value time (open circuit) 50 μs +/- 23 % Generator short circuit current 250 A 1000 A +/- 12 % Generator current front time (shorted) 8 μs +/- 23 % Generator current half value (shorted) 20 μs +/- 23 % The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. Test equipment: Description: Manufacturer: Model number: KIWA ID code Surge tester HAEFELY PC Coupling Filter HAEFELY FP 20 / Digitising Scope HP A Coupling Unit EM test CNV 504 S

7 Report Number: EMC1 EMC Report Page: RS 6/17 Test description: The surges are coupled into the mains supply entrance of the EUT by means of the coupling filter listed in the test equipment table. The coupling unit is used for testing the external wiring. Signal ports are tested when wires may exceed 30 metres according to manufacturer s specifications. For DC power ports this is 10 metres. The time in between pulses must not exceed 60 seconds. Requirements: Performance criterion B: The EUT shall continue to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the EUT is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. No change of actual operating state or stored data is allowed. If the minimum performance level or the performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the EUT if used as intended. Input and output DC terminals allowed to exceed 10 m: Common mode Surge testing according to EN Test level: +/- 0.5 kv, each individual line-earth Start position Two pulses of each polarity for each phase angle (12 per line) Running position One pulse of each polarity for each phase angle (6 per line) Results: Input and output DC terminals exceeding 10 m: Surge testing according to EN Standby position Two pulses of each polarity for each phase angle (12 per wire) Coupling mode: common (2 ohm + 40 ohm, 0.5 µf) L1 to PE L2 to PE Test level Polarity 0.5kV Pos Neg A check mark ( ) indicates test specification has been observed and no EUT response detected.

8 Report Number: EMC1 EMC Report Page: RS 7/17 The EUT complies with performance criterion B of EN Conclusion: The Fire extinguisher activator, brand FirePro Systems, type Activator meets the requirements of EN with regard to immunity to voltage surges. 3.3 Immunity to electrical fast transients/burst (EFT) - Test performed in accordance with EN Severity levels and performance criteria in accordance with EN , clause 8 - KIWA test procedure: WV_EU_EM.TIEF: General procedure for testing the immunity behaviour of electrical and electronic appliances, systems and installations to electrical fast transients - Measurement uncertainty: Parameter: Test level (range): Level uncertainty: Uncertainty in spike amplitude V 12 % Uncertainty in rise time of spike 5 ns 40 % Uncertainty in duration of spike 50 ns 23 % Uncertainty in repetition frequency of 5 khz 0.1 % spikes Uncertainty in duration of the bursts 15 ms 1.7 % Uncertainty in burst period 300 ms 0.1 % The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. Test equipment: Description: Manufacturer: Model number: KIWA ID code EFT generator EM test EFT EMI Noise sensor NOISEKEN FVC EM Clamp Lüthi EM Test description: The EUT is placed in the position in which it is normally operated. A reference ground plane is placed 10 cm behind the EUT in case this is a wall hung appliance. If the EUT is a floor standing appliance, the reference ground plane is placed on the floor and the EUT 10 cm above it. The EUT is placed on a table with a reference plane 10 cm beneath it. The disturbing transients from the EFT generator are coupled into the wires with the use of a coupling device, except for the AC or DC power wires which are connected directly to the generator. When testing 3 phase equipment only one phase is exposed at a time because of the lack of a 3 channel coupling device. The phase that is used in the EUT to power the control electronics is tested first and only when relevant with regard to possible susceptibility the phases are rotated to include the other 2 phases in the test.

9 Report Number: EMC1 EMC Report Page: RS 8/17 Notes: - The disturbance must be present for one minute minimum per polarity of pulses. - Pulses of each polarity are coupled directly to phase, neutral, phase + neutral and phase + neutral + safety earth. - Required pulse repetition frequency: 5 khz Requirements: Performance criterion B: The EUT shall continue to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the EUT is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. No change of actual operating state or stored data is allowed. If the minimum performance level or the performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the EUT if used as intended. Input and output DC power ports with length allowed to exceed 10m Test level Polarity Immunity requirements for compliance with EN kV +/- Criterion B Results: s: start position DC power port Test Level 0.5kV Polarity Pulse Repetition Freq. Pos 5 khz Neg 5 khz s Tested under the relevant condition: standby position: For EFT tests performed on the DC power ports: The EUT complies with the requirements of performance criterion B. Conclusion: The Fire extinguisher activator, brand FirePro Systems, type ACTIVATOR meets the requirements of EN with regard to immunity to electrical fast transients/burst (EFT).

10 Report Number: EMC1 EMC Report Page: RS 9/ Immunity to conducted disturbances - Test performed in accordance with EN Severity levels and performance criteria in accordance with EN clause 8 - KIWA test procedure: WV_EU_EM.TICD: General procedure for testing the immunity behaviour of electrical and electronic appliances, systems and installations to conducted disturbances - Measurement uncertainty: Frequency range Test levels Level uncertainty MHz 1 20 V +2.2 / -2.2 db The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. Test equipment: Description: Manufacturer: Model number: KIWA ID code RF generator Power amplifier ( MHz) Rohde und Schwarz SMY IFI Absorber Clamp Lüthi EM CDN1 (type M2) Comtest CDN2 (type M3) Comtest db attenuator / 15 W Radial R Interface field-probe Holaday HI Field-probe Holaday HI-4421G PC+ Dedicated Software Software: KIWA Clamp Sweep / Test description: The EUT is placed in the position in which it is normally operated. A reference ground plane is placed 10 cm behind the EUT in case this is a wall hung appliance. If the EUT is a floor standing appliance, the reference ground plane is placed on the floor and the EUT 10 cm above it. The EUT is placed on a table with a reference plane 10 cm beneath it. The disturbing signal from the RF generator is coupled into the wires with the use of a coupling device. For AC/DC power ports a CDN is used, for the other ports the EM clamp when the use of a CDN is not practical. The EM clamp is also used for 3 phase equipment. The frequency range is 0.15 to 80 MHz with 80% AM modulation. Requirements: Performance criterion A: The EUT shall continue to operate as intended during and after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer when the EUT is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum

11 Report Number: EMC1 EMC Report Page: RS 10/17 performance level or the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation and what the user may reasonably expect from the EUT if used as intended. Input and output AC/DC power ports, independent of wire length Frequency Immunity requirements for compliance with EN Test level range (MHz) 3Vemf Tested with CDN or clamp (3 phase), Criterion A Signal ports / functional earth ports, length allowed to exceed 3m Frequency Immunity requirements for compliance with EN Test level range (MHz) 3Vemf Tested with CDN or clamp, Criterion A Results: Conducted immunity testing, DC power ports Test voltage V e.m.f. Frequency sweep range Standby position to 80 MHz A check mark ( ) indicates test specification has been observed and no EUT response. Tested under the relevant condition: start position: For conducted disturbances tests performed on the DC power ports: The EUT complies with performance criterion A of EN Conclusion: The Fire extinguisher activator, brand FirePro Systems, type Activator meets the requirements of EN with regard to immunity to conducted disturbances.

12 Report Number: EMC1 EMC Report Page: RS 11/ Immunity to radiated electromagnetic disturbances - Test performed according to EN Severity levels and performance criteria according to EN , clause 8 - KIWA test procedure: WV_EU_EM.TIRD: General procedure for testing the immunity behaviour of electrical and electronic appliances, systems and installations to radiated disturbances - Measurement uncertainty: Frequency range Test levels Level uncertainty MHz 3 20 V/m +5.0 / -0.0 db The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. Test equipment: Description: Manufacturer: Model number: KIWA ID code Bi-conical antenna EMCO Log-Per antenna EMCO RF generator Power amplifier ( MHz) Power amplifier ( MHz) Rohde und Schwarz SMY IFI M IFI M P.S Interface field-probe Holaday HI Field-probe Holaday HI-4421G Turn-table EMCO Positioning controller EMCO Compact Anechoic Chamber COMTEST / TDK CAC-S PC+Dedicated Software Software: KIWA RI_LF.vxe and RI_HF.vxe / Test description: The EUT is placed in the position in which it is normally operated. A turntable is used if possible and applicable to find the angle of the EUT to the impinging field in which it is the most susceptible. External wiring is placed in a position as to create a worst case situation for receiving the disturbing field. During this test the maximum wiring configuration of the EUT is used. Radiated disturbances shall be applied in the frequency range of 80 to 2000 MHz with a field strength of 3 V/m being 80% AM modulated. Radiated disturbances shall be applied in the frequency range of 2000 to 2700 MHz with a field strength of 1 V/m being 80% AM modulated.

13 Report Number: EMC1 EMC Report Page: RS 12/17 Requirements: Performance criterion A: The EUT shall continue to operate as intended during and after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer when the EUT is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation and what the user may reasonably expect from the EUT if used as intended. Frequency range Test level Immunity requirements for compliance with EN MHz 3 V/m, 80% AM Criterion A MHz 3 V/m, 80% AM Criterion A MHz 1 V/m, 80% AM Criterion A Results: Field strength V /m Radiated immunity testing Frequency sweep range 3 80 to 200 MHz to 1000 MHz Polarisation Horizontal Vertical Horizontal Vertical Standby position A check mark ( ) indicates test specification has been observed and no EUT response. Field strength V /m Radiated immunity testing Frequency sweep range to 2000 MHz to 2700MHz Polarisation Horizontal Vertical Horizontal Vertical Standby position A check mark ( ) indicates test specification has been observed and no EUT response. Tested under the relevant condition: standby position: The EUT complies with the requirements of performance criterion A of EN Conclusion: The Fire extinguisher activator, brand FirePro Systems, type Activator meets the requirements of EN with regard to immunity to radiated disturbances.

14 Report Number: EMC1 EMC Report Page: RS 13/ Immunity to electrostatic discharges - Test performed in accordance with EN Severity levels and performance criteria in accordance with EN , clause 8 - KIWA test procedure: WV_EU_EM.TIES: General procedure for testing the immunity behaviour of electrical and electronic appliances, systems and installations to electrostatic discharge - Measurement uncertainty: Parameter: Test level range: Level uncertainty: Uncertainty in discharge voltage 2 kv 8 kv +/- 3.5 % Uncertainty in first peak current A +/- 12 % Uncertainty in rise time of current 0.85 ns +/ ns Uncertainty in value of current after 30 ns 4 16 A +/- 35 % Uncertainty in value of current after 60 ns 2 8 A +/- 35 % The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. Test equipment: Description: Manufacturer: Modelnumber: KIWA ID code ESD generator Schaffner NSG ESD generator Keytek MZ Test description: The EUT is placed in the position in which it is normally operated. A reference ground plane is placed 10 cm behind the EUT in case this is a wall hung appliance. If the EUT is a floor standing appliance, the reference ground plane is placed on the floor and the EUT 10 cm above it. The EUT is placed on a table with a reference plane 10 cm beneath it. In case of a mainly metal enclosure: Contact discharges are preferred and applied directly. Non conductive parts of the EUT that can be touched by the operator during normal operation are subjected to air discharges, while all conductive parts of the EUT accessible to the operator are subjected to contact discharges (this includes also painted surfaces with paint not intended to act as an insulator). In case of a non-conductive enclosure: Contact discharges are preferred and applied indirectly using a coupling plane. Requirements: Performance criterion B: The EUT shall continue to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the EUT is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. No change of actual operating state or stored data is allowed.

15 Report Number: EMC1 EMC Report Page: RS 14/17 If the minimum performance level or the performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the EUT if used as intended. ESD testing / contact discharge / Running, Standby position Voltage Immunity requirements for compliance with EN /- 4 kv criterion B Note: At least ten single contact discharges (in the most sensitive polarity) shall be applied to points that are likely to be touched in normal use, on all conductive parts of the EUT. ESD testing / air discharge / Running, Standby position Voltage Immunity requirements for compliance with EN /- 8 kv criterion B Note: At least ten single air discharges (in the most sensitive polarity) shall be applied to points that are likely to be touched in normal use, on all non conductive parts of the EUT. Results: Contact discharges either applied directly to the conductive surfaces Standby position Voltage + 4 kv - 4 kv A check mark ( ) indicates test specification has been observed and no EUT response. Tested under the relevant condition: standby position: The EUT complies with performance criterion B of EN Conclusion: The Fire extinguisher activator, brand FirePro Systems, type Activator meets the requirements of EN with regard to immunity to electrostatic discharges (ESD).

16 Report Number: EMC1 EMC Report Page: RS 15/17 4. Emission measurements Utilised measurement equipment and methods in accordance with CISPR 11 and CISPR Radiated disturbances (30 MHz 1000 MHz) - Measurement performed in accordance with EN Measurement method conform basic standard EN Limits in accordance with EN KIWA test procedure WV_EU_EM.TERD: General procedure for testing the emission of electrical and electronic appliances, systems and installations of radiated disturbances - Measurement uncertainty: Frequency range Result values Measurement uncertainty MHz dbμv/m +8.6 / -6.9 db MHz dbμv/m +7.1 / -5.9 db The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. Test equipment: Description: Manufacturer: Model number: KIWA ID code Bi-conical antenna EMCO Log-Per antenna EMCO Antenna Cable KIWA N.A EMI Test receiver Rohde und Schwarz ESVS Compact Anechoic Chamber COMTEST / TDK CAC-S PC+Dedicated Software Test description: Software: Rohde und Schwarz ESxS-K1 Version 2.10 Part.no / Radiated emission is measured according to EN Class A Group I. The measurements are performed in a CALC. The results are converted to 10m OATS response so they can be compared to the limits directly. Measurements are made with a quasi peak detector. The EUT is placed in the position in which it is normally operated with regard to the material of the enclosure, the length of the leads and the presence of an earth connection. The EUT will be tested in all relevant operating modes. Requirements: The radiated emission of the EUT must satisfy the following field strength limits for both horizontal and vertical polarization: Frequency range 30Mz 230 MHz 230Mz 1000 MHz QP Limit 40 db(μv/m) 47 db(μv/m)

17 Report Number: EMC1 EMC Report Page: RS 16/17 Results: For results of the radiated emission measurement in the frequency band from 30 MHz 1000 MHz see figures R1 to R4: Figure R1 PASS Radiated emission MHz Horizontal polarization (start position) Figure R2 PASS Radiated emission MHz Vertical polarization (start position) Figure R3 PASS Radiated emission MHz Horizontal polarization (start position) Figure R4 PASS Radiated emission MHz Vertical polarization (start position) Conclusion: The Fire extinguisher activator, brand FirePro Systems, type Activator meets the requirements of EN with regard to emission of radiated disturbances. 4.2 Conducted continuous disturbances ( MHz) - Measurements performed in accordance with EN Measurement method conform basic standard EN (CISPR 11) - Limits in accordance with EN KIWA test procedure WV_EU_EM.TECD: General procedure for testing the emission of electrical and electronic appliances, systems and installations of conducted disturbances - Measurement uncertainty: db / db, when both QP & AV results are between 30 dbμv and 100 dbμv The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. Test equipment: Description: Manufacturer: Model number: KIWA ID code Artificial mains network EMI Test receiver PC+ Dedicated Software Rohde und Schwarz Rohde und Schwarz Software: Rohde und Schwarz ESH2-Z ESHS ESxS-K1 Part. no ser no: RSS.0000/ / Test description: With the reference ground plane placed 10 cm beneath or behind it the EUT mains terminals are measured according to EN The EUT is placed in the position in which it is normally operated, with regard to the

18 Report Number: EMC1 EMC Report Page: RS 17/17 material of the enclosure, the length of the leads and the presence of an earth connection. Measurements are made on both neutral and phase (or N and L1+L2+L3 for 3 phase equipment) with the use of an AMN (Artificial Mains Network). Requirements: The conducted continuous emission of the EUT must satisfy the following terminal voltage limits: Frequency range At mains terminals At load terminals and at additional terminals [MHz] dbμv dbμv dbμv dbμv Quasi peak Average Quasi peak Average 0.15 to under under consideration consideration 0.50 to under consideration under consideration 5 to under consideration under consideration Results: For results of the conducted continuous disturbance measurements in the frequency band from 150 khz to 30 MHz see figure C1: Figure C1 PASS Conducted emission in standby position Conclusion: The Fire extinguisher activator, brand FirePro Systems, type Activator meets the requirements of EN with regard to emission of conducted continuous disturbances.

19 KIWA CERTIFICATION B.V. FILES Report Number: %%RappNr EMC Report Page: GF 1/00 N.v.t. PM LM NR OMSCHRIJVING ( ) ( ) ( ) 1 Inhoudsopgave: Is deze conform inhoud van het rapport? 2 Algemeen: Zijn type nummers in het gehele rapport uniform aangegeven? 3 Algemeen: Is keuringsobject voldoende vastgelegd (b.v. tekeningen / stuklijst / foto s)? 4 Algemeen: Is iedere pagina van het rapport voorzien van een rapportnummer? 5 Algemeen: Is iedere pagina van het rapport voorzien van paraaf van de verantwoordelijke engineer(s) en een overall paraaf van de PM? 6 Heading Sheets: Zijn NAW gegevens van de fabrikant in orde? 7 Heading Sheets + Summary Sheets: Zijn vermelde normen conform offerte (incl. eventueel certificaat + bijlage certificaat)? 8 Modification: -Zijn modificaties in voldoende detail beschreven? -Is testprogramma voldoende onderbouwd? -Zijn testresultaten duidelijk vastgelegd? 9 Test Sheets: Zijn alle artikelen ingevuld? 10 Test Sheets: Komen test sheets overeen met de product specificaties? 11 Test Sheets: Zijn verwijzingen naar andere bladen in orde? 12 Result Sheets: Zijn relevante sample nummers aangeven? 13 Result Sheets: Is technisch inhoudelijk akkoord? 14 Result Sheets: Is de locatie waar de testen zijn uitgevoerd duidelijk aangegeven? 15 Result Sheets: Is eventuele uitbesteding duidelijk aangegeven? 16 Result Sheets: Is nagegaan of uitbesteding in de lijst van standaard toeleveranciers voorkomt? 17 Tekeningen: Is de inhoudsopgave in orde? 18 Tekeningen: Zijn alle tekeningen gestempeld? 19 KIWA Files: Is alle ruwe test data bijgevoegd (eventueel in een separate map) en voorzien van een projectnummer? 20 KIWA Files:Is rapport overeenkomstig met de ruwe data? 21 KIWA Files: Zijn eventuele aandachtspunten m.b.t. product controle aangegeven? 22 KIWA Files: Zijn offerte en klanten order toegevoegd en voorzien van een projectnummer? 23 Correspondentie Files: -Is relevante correspondentie toegevoegd (eventueel in een separate map) en voorzien van een projectnummer? -Is alleen die correspondentie toegevoegd t.a.v. testresults die niet op andere wijze in het rapport voorkomt? 24 Opleiding: Zijn de Test Engineers geautoriseerd voor de betreffende verrichtingen? 25 Opleiding: Zijn er Test Engineers die nog onder mentorschap staan en zo ja heeft de verantwoordelijke mentor getekend voor akkoord? 26 Rapport retour aan Test Engineer voor doorvoeren verbeteringen? J/N 27 Certificering: Is project begeleidingsformulier CZ 0063 bijgevoegd en volledig ingevuld? 28 Certificering: Komen de certificatie gegevens (certificaat en/of bijlage) overeen met de gegevens in het rapport? 29 Certificering: Is rapport geaccepteerd (niet ingevuld betekent dat er (nog) geen opmerkingen van de Certificeerder zijn ontvangen *)? *): Opmerkingen van CZ:... Maatregelen door Lab:... Paraaf akkoord PM/LM:.. Job reference: %%JobNr Initials

20

CE EMC Test Report EN :2015 EN :2017. Folder with powerbank ZKS E. Lieber Ouyang (Engineer) Lahm Peng (Manager)

CE EMC Test Report EN :2015 EN :2017. Folder with powerbank ZKS E. Lieber Ouyang (Engineer) Lahm Peng (Manager) CE EMC Test Report Test Standard(s): Applicant: Product Name: EN 55032 :2015 EN 55035 :2017 Goya Importacionesy Distribuciones SL B50154293 Folder with powerbank Model: 606090 Report No.: ZKS180800212E

More information

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka Last Amended on 07.10.2015 Page 1 of 18 I. EMC Test Facility 1. Electrical and Electronic Products, Process Control Devices, Lighting Control Products, Sensing and Control Devices, Electromechanical Products,

More information

FCC COMPLIANCE REPORT. SHENZHEN STARWELL TECHNOLOGY CO., Ltd. AC/DC ADAPTER

FCC COMPLIANCE REPORT. SHENZHEN STARWELL TECHNOLOGY CO., Ltd. AC/DC ADAPTER FCC COMPLIANCE REPORT SHENZHEN STARWELL TECHNOLOGY CO., Ltd. for AC/DC ADAPTER Model Number : SMS-01XXXYYY-S06 XXX Stand for output voltage; YYY Stand for output current Prepared for : SHENZHEN STARWELL

More information

Supplementary type approval testing of Selco modules

Supplementary type approval testing of Selco modules We help ideas meet the real world DELTA Test Report DANAK TEST Reg. no. 19 Supplementary type approval testing of Selco modules Performed for Selco A/S DANAK-198611 Project no.: A504377-1 Page 1 of 20

More information

Application for FCC Certificate On Behalf of. TTE Technology, Inc. LCD TV or LED TV. Model Number: 32R20 FCC ID:W8U32R20

Application for FCC Certificate On Behalf of. TTE Technology, Inc. LCD TV or LED TV. Model Number: 32R20 FCC ID:W8U32R20 Application for FCC Certificate On Behalf of TTE Technology, Inc. LCD TV or LED TV Model Number: 32R20 FCC ID:W8U32R20 Prepared for : TTE Technology, Inc. Address : 2455 Anselmo Drive Suite 101 Corona

More information

Application for FCC Certificate On Behalf of. TTE Technology, Inc. LCD TV or LED TV. Model Number: 55R80 FCC ID:W8U55R80

Application for FCC Certificate On Behalf of. TTE Technology, Inc. LCD TV or LED TV. Model Number: 55R80 FCC ID:W8U55R80 Application for FCC Certificate On Behalf of TTE Technology, Inc. LCD TV or LED TV Model Number: 55R80 FCC ID:W8U55R80 Prepared for : TTE Technology, Inc. Address : 2455 Anselmo Drive Suite 101 Corona

More information

RF TEST REPORT. ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS RXC RF07

RF TEST REPORT. ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS RXC RF07 RF TEST REPORT Applicant FCC ID Brand Product ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS Model VFD 511 Multi-Mode Digital Mobile Phone Report No. RXC1703-0087RF07 Issue Date May 24,2017 TA Technology

More information

Sunlight Supply, Inc.

Sunlight Supply, Inc. FCC Part 18 Subpart C Consumer For RF Lighting Equipment Electromagnetic Compatibility Test Report Sunlight Supply, Inc. December 19, 2017 Tests Conducted by:, LLC 20811 NW Cornell Road, Suite 600, Hillsboro,

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Langer Road Contact: Mr I Frost Felixstowe Tel: +44 (0)1394 694000 Suffolk Fax: +44 (0)1394 276030 IP11 2ER E-Mail: ian.frost@itron.com Website:

More information

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer TEST REPORT IEC 61000-4-2-2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test Report Reference No....: SQE13090002 R/C: 60520

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE CERTIFICATION SERVICES, INC. 1 Xindian Laboratory No.163-1, Jhongsheng Road Xindian District, New Taipei City 23151, Taiwan, R.O.C. Contact: Kurt

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Unit 8 Contact: Mrs G Baker Woodfieldside Business Park Tel: +44 (0)1495 229219 Pontllanfraith Fax: +44 (0)1495 228331 Blackwood E-Mail: ginnie.baker@kiwa.co.uk

More information

Audible warning devices for external alarm

Audible warning devices for external alarm VdS SCHADENVERHÜTUNG VdS Publisher: Gesamtverband der Deutschen Versicherungswirtschaft e.v. (GDV) Büro Schadenverhütung Publishing house: VdS Schadenverhütung Rules for Intruder Alarm Systems Audible

More information

REA 105 Arc Protection Module. Operator s Manual

REA 105 Arc Protection Module. Operator s Manual REA 105 1MRS 751005-MUM Issued: 20.04.1998 Version: B2/26.5.2000 Checked: Approved: REA 105 We reserve the right to change data without prior notice. Contents: 1. General...4 1.1. Features...4 2. Safety...5

More information

CENELEC GUIDE 24. Electromagnetic Compatibility (EMC) Standardization for Product Committees concerned with apparatus. Edition 3,

CENELEC GUIDE 24. Electromagnetic Compatibility (EMC) Standardization for Product Committees concerned with apparatus. Edition 3, CENELEC GUIDE 24 Electromagnetic Compatibility (EMC) Standardization for Product Committees concerned with apparatus Edition 3, 2009-12 This third edition of CENELEC Guide 24, prepared by CENELEC Technical

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that LabTest Certification, Inc. 3128 20800 Westminster

More information

VAMP 120 & 121. Arc flash detection units. Product picture

VAMP 120 & 121. Arc flash detection units. Product picture Arc flash detection units VAMP 120 and 121(D) are extremely fast arc flash detection units for LV and MV switchgear and controlgear. The units are especially designed to increase the safety and to minimize

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SHANGHAI INSPECTION AND TESTING INSTITUTE OF INSTRUMENTS AND AUTOMATION SYSTEMS CO., LTD. 103 Cao Bao Road Shanghai, 200233 People s Republic of China Mr. Xu

More information

PIR movement and presence detectors 10 A

PIR movement and presence detectors 10 A PIR movement and presence detectors 10 A Hotel room energy-enabling units ighting control in corridors (for hotels, offices and hospitals) Offices, swimming baths and schools SЕRIES Staircase light control

More information

AUGUST 2016 CONTENTS:

AUGUST 2016 CONTENTS: EMC SERVICES NEWSLETTER AUGUST 2016 CONTENTS: RECENT STANDARD CHANGES NEW FCC REGULATIONS IEC 60601-1-2 4TH EDITION LOW VOLTAGE DIRECTIVE EU DIRECTIVES EMC DIRECTIVE 2014/30/EU KOREA UPDATE: KN32/35 1.

More information

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor DSF xx15.xx xhv Ex-Atex Product ID Type # Product # Drawing # DSF 1215.01 SHV Ex-atex (5m) 304Z-05197 113216 DSF 1415.01 AHV Ex-atex S148 304Z-05256 113351 DSF 1615.01 SHV Ex-atex (5m) 304Z-05196 113214

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Stable Court Contact: Mark Richens Oakley Tel: +44 (0)1630 658568 Nr Market Drayton Fax: +44 (0)1630 658921 Shropshire E-Mail: mark@cranage.co.uk

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Standards Institution of Israel Electronics

More information

EMC Emissions in the Machine Industry

EMC Emissions in the Machine Industry EMC Emissions in the Machine Industry Technical lecture by Herbert Blum 09.02.11 1 Programme > > Applicable Standard EN55011:2009 > Practical Examples 09.02.11 2 European Directives >The basic requirements

More information

Compliance Engineering Ireland Ltd

Compliance Engineering Ireland Ltd Clonross, Dunshaughlin, Co. Meath Testing Laboratory Registration number: 088T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule bearing the Registration

More information

This annex is valid from: to Replaces annex dated: Prolonged until

This annex is valid from: to Replaces annex dated: Prolonged until Registration : L 022 This annex is valid from: 13-09-2017 to 01-03-2018 Replaces annex dated: 13-06-2016 Prolonged until 01-09-2018 Meander 1051 6825 MJ Arnhem The Netherlands Location(s) where activities

More information

Test Report No EEC12/08 dated 18 Jun 2012

Test Report No EEC12/08 dated 18 Jun 2012 Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group and the General Terms and Conditions of Business of TÜV SÜD PSB Pte Ltd. In addition, this report is

More information

Compliance Engineering Ireland Ltd

Compliance Engineering Ireland Ltd Clonross, Dunshaughlin, Co. Meath Testing Laboratory Registration number: 088T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule bearing the Registration

More information

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd. Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd. Copyright Clipsal Australia Pty Ltd, 2008. All rights reserved. This material is copyright

More information

COMITÉ EUROPÉEN DES ASSURANCES

COMITÉ EUROPÉEN DES ASSURANCES COMITÉ EUROPÉEN DES ASSURANCES SECRETARIAT GENERAL 3bis, rue de la Chaussée d'antin F 75009 Paris Tél. : +33 1 44 83 11 73 Fax : +33 1 44 83 11 85 Web : cea.assur.org DELEGATION A BRUXELLES Square de Meeûs,

More information

Test Report Garvan Enterprises Limited

Test Report Garvan Enterprises Limited Test Report 8526255. Garvan Enterprises Limited Page 1 of 14 Introduction. This report has been prepared by A Reeve and relates to the activity detailed below: Job/Registration Details Job number: 8526255

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 LABORATOIRE D ESSAIS CEM INC. 1490-D Nobel Street Boucherville, Quebec, Canada J4B 5H3 Mr. Xavier Couste Phone: 450 868 0360 Email: Xavier.Couste@nts.com ELECTRICAL

More information

VAMP 121. Arc protection unit. User manual

VAMP 121. Arc protection unit. User manual VAMP 121 Arc protection unit User manual VM121.EN014_B Table of contents VAMP 121 Table of contents 1. General... 4 1.1. Arc protection unit VAMP 121... 4 2. Unit configuration... 6 3. Sensors... 8 3.1.

More information

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID Product ID Type # Product # Drawing # 378Z-05380 DSS 1210.00 STV (5m) 113807 374Z-04996 DSS 1210.02 PHV 112705 374Z-05052 DSS 1210.02 SHV (2m) 112865 378Z-05864 DSS 1210.12 AHV 115675 378Z-05910 DSS 1210.13

More information

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Additional Rules and Guidelines VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 7 Test Requirements for Statical Converters with Semi-Conductors Edition

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Wallace Way Tern Valley Business Park Market Drayton Shropshire TF9 3AG Contact: Mark Richens Tel: +44 (0) 1630 658568 E-Mail: mark@cranage.co.uk

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Standards Institution of Israel Electronics

More information

VdS SCHADENVERHÜTUNG. VdS-Rules for Intruder Alarm Systems

VdS SCHADENVERHÜTUNG. VdS-Rules for Intruder Alarm Systems VdS SCHADENVERHÜTUNG VdS Publisher: Gesamtverband der Deutschen Versicherungswirtschaft e.v. (GDV) Büro Schadenverhütung Publishing house: VdS Schadenverhütung. All rights reserved. VdS-Rules for Intruder

More information

Universal fault annunciator for panel mounting

Universal fault annunciator for panel mounting Universal fault annunciator for panel mounting Communication over Ethernet USM - Universal-fault annunciator for panel mounting Low depth housing for panel mounting Versions with 8, 16, 32 or 48 inputs

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE CERTIFICATION SERVICES INC. 1 Kunshan Laboratory No. 10 Wei ye Road Innovation Park Eco & Tec. Development Zone Kunshan City, Jiangsu, People s Republic

More information

Recent Topics in IEC TC 62 (Electrical Equipment in Medical Practice) and its Subcommittees

Recent Topics in IEC TC 62 (Electrical Equipment in Medical Practice) and its Subcommittees INTERNATIONAL ELECTROTECHNICAL COMMISSION Recent Topics in IEC TC 62 (Electrical Equipment in Medical Practice) and its Subcommittees Don Heirman presenting for Robert Sitzmann (TC 62) APEMC symposium

More information

This is a preview - click here to buy the full publication

This is a preview - click here to buy the full publication TECHNICAL REPORT IEC TR 60601-4-2 Edition 1.0 2016-05 colour inside Medical electrical equipment Part 4-2: Guidance and interpretation Electromagnetic immunity: performance of medical electrical equipment

More information

This document is a preview generated by EVS

This document is a preview generated by EVS IEC 61000-6-2 Edition 3.0 2016-08 REDLINE VERSION colour inside Electromagnetic compatibility (EMC) Part 6-2: Generic standards Immunity standard for industrial environments IEC 61000-6-2:2016-08 RLV(en)

More information

Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH

Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH Manufacturer: Redsense Medical AB Gyllenhammars väg 26 302 92 HALMSTAD SWEDEN www.redsensemedical.com These instructions are

More information

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305 High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305 The new high-power Q305 laser is an expansion of the existing Q-Series that provides a solution for demanding applications requiring faster throughput.

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE ENGINEERING PTY LTD 90 Indian Drive Keysborough, Victoria 3173, AUSTRALIA Mr. Simon Grilj Phone: 61 3 9763 3079 Email: simon@compeng.com.au ELECTRICAL

More information

Technical evaluation of the Ningbo Longmax Electronic Co., Ltd LM-201A battery operated carbon monoxide (CO) Detector Type B to EN :2010.

Technical evaluation of the Ningbo Longmax Electronic Co., Ltd LM-201A battery operated carbon monoxide (CO) Detector Type B to EN :2010. Technical evaluation of the Ningbo Longmax Electronic Co., Ltd LM-201A battery operated carbon monoxide (CO) Detector Type B to EN 50291-1:2010. Prepared for: LPCB Bucknalls Lane Garston Watford WD25 9XX

More information

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S / Introduction /3 photoelectric sensors /5 ultrasonic sensors /6 4 sensor module for ET 00S /6 8 sensor module for ET 00M/S7-300 Introduction Configuration/parameterization Uniform configuration tools

More information

Test Report. Appliance EMF Testing

Test Report. Appliance EMF Testing Project: 11014506A Date: November 6, 2015 Model: 120V_WWF13NW Test Report On Appliance EMF Testing Copyright 2005 UL LLC UL LLC authorizes the above-named company to reproduce this Report provided it is

More information

STS Directory Accreditation number: STS 0009

STS Directory Accreditation number: STS 0009 International standard: ISO/IEC 17025:2005 Swiss standard: SN EN ISO/IEC 17025:2005 Mettler-Toledo GmbH ENL Testing Laboratory Heuwinkelstrasse 3 8606 Naenikon SWITZERLAND Head: Bernhard Merk Responsible

More information

Installation Instructions for the

Installation Instructions for the Installation Instructions for the Particle Sensors General Information The Honeywell Particle Sensor is a laser-based sensor which uses the light scattering method to detect and count particles in the

More information

Smoke and heat control systems - Part 10: Power supplies EN Classification according to operational and environmental class

Smoke and heat control systems - Part 10: Power supplies EN Classification according to operational and environmental class Smoke and heat control systems - Part 10: Power supplies EN 12101-10 Classification according to operational and environmental class I.F.I. Institut für Industrieaerodynamik GmbH Welkenrather Straße 120

More information

Fisher LCP100 Local Control Panel

Fisher LCP100 Local Control Panel Instruction Manual LCP100 Local Control Panel Fisher LCP100 Local Control Panel Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Installation... 3 Hazardous Area Classifications

More information

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits Arc Protection 01 VAmP 120 Arc Flash Protection Units Customer benefits Personnel Safety A fast and reliable arc protection unit may save human lives in case of an arc fault arising in a switchgear during

More information

This is a preview - click here to buy the full publication

This is a preview - click here to buy the full publication TECHNICAL REPORT IEC TR 61000-4-1 Edition 1.0 2016-04 BASIC EMC PUBLICATION Electromagnetic compatibility (EMC) Part 4-1: Testing and measurement techniques Overview of the IEC 61000-4 series INTERNATIONAL

More information

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks TEST REORT SUMMARY EN 50438 Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks Report reference number... : 12TH0525-EN50438_SUM_0 Date of issue......:

More information

Technical Specification PILATUS 100K Detector System

Technical Specification PILATUS 100K Detector System Technical Specification PILATUS 100K Detector System Vesion 1.0 Table of Contents 1 Document History...4 1.1 Changes...4 2 Technical specifications...5 2.1 Technical data...5 2.2 Normal operation...6 2.3

More information

Rules for Intruder Alarm Systems

Rules for Intruder Alarm Systems Rules for Intruder Alarm Systems Opening detectors (Magnetic contacts) Part 1: Requirements VdS 2120en 03/96 (03) Subject 44 1 General; 2 Terms and definitions; 3 Classification 1 General 1.1 Scope These

More information

Delta XRD. Supervision Relays. rms A U X I L I A R Y T R I P P I N G S U P E R V I S I O N

Delta XRD. Supervision Relays. rms A U X I L I A R Y T R I P P I N G S U P E R V I S I O N Delta XRD A U X I L I A R Y T R I P P I N G S U P E R V I S I O N Supervision Relays The XRD is a compact high performance supervision relay for power utility protection and control applications. > Trip

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 QAI LABORATORIES, INC. 1 834 80 th Street SW, Suite 200 Everett, WA 98203 Contact: Jarred Johnsen Phone: 425 512 8419 ELECTRICAL Valid To: February 28, 2017

More information

Guide Specification Model CTG Automatic Transfer Switch

Guide Specification Model CTG Automatic Transfer Switch Guide Specification Model CTG Automatic Transfer Switch PART 1 GENERAL 1.1 Scope A. It is the intent of this specification to secure a transfer switch that has been prototype tested, factory built, production

More information

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P Contents Description Data Sheet No. Page Overview P-1.50.001E 117-118 Technical Data SFI-plus P-1.50.002E-1, 2 119-120 Dimensions

More information

Recent Topics in IEC TC 62 (Electrical Equipment in Medical Practice) and its Subcommittees

Recent Topics in IEC TC 62 (Electrical Equipment in Medical Practice) and its Subcommittees INTERNATIONAL ELECTROTECHNICAL COMMISSION Recent Topics in IEC TC 62 (Electrical Equipment in Medical Practice) and its Subcommittees Don Heirman presenting for Robert Sitzmann (TC 62) APEMC symposium

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE MANAGEMENT GROUP (CMG) 1 257 Simarano Drive, Suite 4 Marlborough, MA 01752 Authorized Representative: Mike Morrow Phone: 508 460 1400 ext. 222 Email:

More information

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl enproteko.com Temperature Monitoring Relay K8AB-TH Compact and Slim Relay Ideal for Temperature Alarms and Monitoring Excessive increases can be prevented and abnormal s can be monitored. Temperature monitoring

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60044-7 First edition 1999-12 Instrument transformers Part 7: Electronic voltage transformers This English-language version is derived from the original bilingual publication

More information

DIGITIAL PROTECTION COUPLER

DIGITIAL PROTECTION COUPLER DIGITIAL PROTECTION COUPLER September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091.

More information

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series FT702LT Turbine control wind sensor......gives durability a new meaning FT702LT series Proven High Availability The FT702LT ultrasonic anemometer is the result of FT Technologies 10 years of experience

More information

Kiwa Nederland B.V. Unit Appliances & Controls, Unit Automotive, Unit Gasdistribution Materials and Unit ExVision

Kiwa Nederland B.V. Unit Appliances & Controls, Unit Automotive, Unit Gasdistribution Materials and Unit ExVision of Kiwa Nederland B.V. Sir Winston Churchill-laan 273 2288 EA Rijswijk The Netherlands Location(s) where activities are performed under accreditation Head Office Location Abbreviation/ location code Main

More information

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS SPECIFICATIONS Mountable with O-ring seal Stainless Steel wetted surfaces Amplified ASIC calibrated Absolute, sealed gage Cable option Analog output SENT Output Optional (contact factory for details) FEATURES

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Standards Institution of Israel Electricity

More information

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. FCC MPE REPORT

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. FCC MPE REPORT No. 588 West Jindu Road, Songjiang District, Shanghai, China Telephone: +86 (0) 21 61915666 Fax: +86 (0) 21 61915678 ee.shanghai@sgs.com Page 1 of 8 1 Cover Page Application No.: Applicant: FCC MPE REPORT

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ARTESYN PRODUCT TESTING SERVICES 2900 South Diablo Way, Suite 190 Tempe, AZ 85282 Tom Tuttle Phone: 602 228 7869 Email: tom.tuttle@artesyn.com ELECTRICAL (EMC)

More information

EMC Bayswater Pty Ltd

EMC Bayswater Pty Ltd EMC Bayswater Pty Ltd EMC BAYSWATER PTY LTD Accreditation Number: 18553 Site Number: 20485 Address Details: Unit 18, 88 Merrindale Drive CROYDON SOUTH, VIC 3136 AUSTRALIA Website: www.emcbayswater.com.au

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 CENTRE TESTING INTERNATIONAL GROUP CO., LTD. 1 Building C, Hongwei Industrial Park Block 70, Bao'an District Shenzhen, Guangdong, People s Republic of China

More information

M7100 Pressure Transducer

M7100 Pressure Transducer SPECIFICATIONS Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces

More information

C-Bus Four Channel Analogue Output Unit Installation Instructions

C-Bus Four Channel Analogue Output Unit Installation Instructions C-Bus Four Channel Analogue Output Unit Installation Instructions 5504AMP Series REGISTERED PATENT Table of Contents Section... Page 1.0 Product Range...3 2.0 Description...3 3.0 Capabilities...3 4.0 Wiring

More information

EMC in Industrial electronics PE:Region EMC/EMI in overview basic principles, current state of technology

EMC in Industrial electronics PE:Region EMC/EMI in overview basic principles, current state of technology EMC in Industrial electronics PE:Region EMC/EMI in overview basic principles, current state of technology Flensburg, Per Thåstrup Jensen February 2018 Agenda Why bother with EMC? The basic EMC parameters

More information

ANSI-ASQ National Accreditation Board/ACLASS

ANSI-ASQ National Accreditation Board/ACLASS ANSI-ASQ National Accreditation Board/ACLASS SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Washington Laboratories, Ltd. 1, 2 7560 Lindbergh Drive, Gaithersburg, Maryland 20879 John Repella Phone: 301-216-1500

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Washington Laboratories, Ltd. 7560 Lindbergh

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Labtest Certification, Inc. 3128, 20800 Westminster

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60533 Second edition 1999-11 Electrical and electronic installations in ships Electromagnetic compatibility Installations électriques et électroniques à bord des navires Compatibilité

More information

How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab

How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab For questions and details contact Dennis at dennis@emitestlab.com Introduction The CE mark (an acronym for the French

More information

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION HPM Series Particle Sensor DESCRIPTION The Honeywell HPM Series Particle Sensor is a laser-based sensor which uses the light scattering method to detect and count particles in the concentration range of

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 62052-11 First edition 2003-02 Electricity metering equipment (AC) General requirements, tests and test conditions Part 11: Metering equipment This English-language version is

More information

M5200 Industrial Pressure Transducer

M5200 Industrial Pressure Transducer SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber CE Compliant and Weatherproof UL Certified Gage, Sealed, Compound

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61000-4-3 Edition 2.1 2002-09 Edition 2:2002 consolidated with amendment 1:2002 BASIC EMC PUBLICATION Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement techniques

More information

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR 7 783 DETACTOGYR Flame Safeguard The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil or gas burners or

More information

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new

More information

3kW 6kW, QUBE Fiber Lasers

3kW 6kW, QUBE Fiber Lasers 3kW 6kW, QUBE Fiber Lasers CONTENTS 1.1 SCOPE 2 1.2 OPTICAL SPECIFICATION 2 1.3 BEAM DELIVERY FIBER SPECIFICATION 3 1.4 SHARE UNITS 3 1.5 ALIGNMENT LASER 3 1.6 POWER DISTRIBUTION 4 1.7 WATER COOLING REQUIREMENTS

More information

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24 Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24 Soft starting of 1-Phase Scroll Compressors Enclosed solution Integrated current limit Rated operational voltage: 230 VACrms, 50/60

More information

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24.. Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24.. Soft starting of 1-Phase Scroll Compressors Enclosed solution Integrated current limit Rated operational voltage: 230 VACrms,

More information

Parameterisable compact fault annunciator with permanent display

Parameterisable compact fault annunciator with permanent display Parameterisable compact fault annunciator with permanent display FSM 10 Drop-flap fault annunciator 31.08.2010 Permanent display even on power failure Compact module for 10 alarms Supply and alarm signal

More information

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications MEAS 5700 Subermsible Liquid Level Pressure Transducer Features Heavy Industrial CE Approval 10 V/m EMI Protection Reverse Polarity Protection on Input Short Circuit Protection on Output ±0.25% Accuracy

More information

Type approval testing of miscellaneous smoke and heat detectors for marine applications

Type approval testing of miscellaneous smoke and heat detectors for marine applications We help ideas meet the real world DELTA Test Report TEST Reg. no. 19 Type approval testing of miscellaneous smoke and heat detectors for marine applications Performed for Consilium Marine AB DANAK-199842

More information

Product Tests Report

Product Tests Report TO WHOM IT MAY CONCERN Page: 1 of 5 Product name: Model number and description: MIC IP starlight 7000i Product Tests Report MIC-7502-Z30B, PTZ camera 2MP HDR 30x IP68 IK10, black MIC-7502-Z30W, PTZ camera

More information

PM-200 Power Module Operating Instructions

PM-200 Power Module Operating Instructions PM-200 Power Module Operating Instructions Terahertz Technologies Inc. 169 Clear Road, Oriskany, NY 13424 (315) 736-3642 FAX (315) 736-4078 E-mail tti@borg.com Contents Introduction... 1 Specifications...

More information

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24.. Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24.. Soft starting of 1-Phase Scroll Compressors Enclosed solution Integrated current limit Rated operational voltage: 230 VACrms, 50/60

More information

Hong Kong Association for Testing, Inspection and Certification Ltd. S.W.N. Ho. (Electrical Products Testing)

Hong Kong Association for Testing, Inspection and Certification Ltd. S.W.N. Ho. (Electrical Products Testing) Hong Kong Association for Testing, Inspection and Certification Ltd. Professional Certification Scheme for Testing Personnel (Electrical Products Testing) S.W.N. Ho 1 Examination (CTT) Disclaimer Criteria,

More information

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation Annex to declaration accreditation (scope accreditation) Location(s) where activities are performed under accreditation Head Office Thijsseweg 11 2629 JA lft The Netherlands Location 1 Abbreviation/ location

More information