Mobile measurement technology for HV components

Size: px
Start display at page:

Download "Mobile measurement technology for HV components"

Transcription

1 Mobile measurement technology for HV components Also for AD and PT measurement modules!

2 CONTENT page The companies Safe temperature measurement on HV components Application example HV Thermo-Scan MiniModul Product range 4-channel HV thermocouple cable Item no. L channel HV thermocouple cable Item no. L channel HV thermocouple cable Item no. L channel HV PT sensor cable (4-wire measurement techniques) Item no. L channel HV PT sensor cable (4-wire measurement techniques) Item no. L HV analog sensor cable Item no. L / Item no. L

3 THE COMPANIES FOUNDED IN 1947 by Peter Bröckskes sen. An independent, middle sized company FOUNDED IN 1983 by Iris Koch and Dr. Winfried Koch as a privately held technology company CEO Peter Bröckskes and Sabine Bröckskes-Wetten PLANT/LOCATION in Viersen (lower Rhine) m² company site manufacturing from copper conductor to, thermocouples, resistance thermometers, cable harnessing, own VDE approved burning chamber and laboratory STAFF approx. 420 in Viersen, 500 worldwide TURNOVER approx. 95 million worldwide PRODUCTS < special cables < thermo technique < cable harnessing CERTIFICATES AND APPROVALS quality management system acc. to ISO 9001: 2008 for all production fields, environmental management system acc. to 14001:2004, occupational health and safety management acc. to NLF/ILO-OSH 2001 and OHSAS 18001:2007, energy management system acc. to DIN EN ISO 50001:2011 CEO Iris Koch Dr. Winfried Koch PLANT/LOCATION CSM Computer-Systeme-Messtechnik GmbH Filderstadt near Stuttgart STAFF approx. 65 in Filderstadt, 70 worldwide PRODUCT PORTFOLIO CSM is a leading and independent supplier of: < measurement technology and data logger for the application in all kinds of vehicles and at test benches < PC card drives, data loggers and storage media for many industrial applications < programming tools for control devices CERTIFICATES AND APPROVALS certified acc. to DIN EN ISO 9001 since 2002, certified acc. to DIN EN ISO since 2004, own test laboratory for EMC tests, laboratory for calibrations with DAkkS approval (D-K ) 3

4 SAFE TEMPERATURE MEASUREMENT ON HV COMPONENTS The measurement system is especially designed for safe temperature measurement on HV components and is excellently suited for mobile and stationary use in the field of electric mobility: electric and hybrid vehicles. Tested safety from measuring point to data logging temperature measurement on HV components suitable for mobile and stationary use in the field of e-mobility it can be used in close proximity to the measuring point type test of the complete system by an accredited laboratory power electronic test bench of the company Digatron for electric vehicle batteries 4

5 APPLICATION EXAMPLE notebook with DAQ SW CAN bus data logger CAN interface battery block CAN bus HV sensor cable 4 x thermocouples HV THMM 4 5

6 HV THERMO-SCAN MINIMODUL 4 NiCr-Ni (type K) temperature inputs galvanic insulation: reinforced insulation up to 846 V unipolar n channel / channel n channel / CAN n channel / supply n channel / housing type and routine test according to device safety standard EN outstanding measurement accuracy for all temperature ranges and environmental conditions internal cold junction compensation per channel very low power consumption typ. 1 W operating temperature -40 C to +100 C protection class IP67 robust aluminium housing extremely compact CAN bus measurement device 6

7 4-CHANNEL HV THERMOCOUPLE CABLE Item no. L connector cable with double insulation measuring tip S BRÖCKSKES D-VIERSEN CSM GMBH D-FILDERSTADT L ( TYP K HV-SENSOR ( 2,0 m 0,4 m inner sheath HV-TC marking thermocouple type K thermocouple cable type K 4 x 2 x 0,20 mm Ø Protected construction type (channel 1-4) (measuring tips insulated, equally protected) S BRÖCKSKES D-VIERSEN CSM GmbH D-FILDERSTADT L ( Typ K HV-SENSOR ( approx. 6,1 mm Construction type of measuring tip according to customer s specification Routine test 7

8 4-CHANNEL HV THERMOCOUPLE CABLE Item no. L connector cable with double insulation measuring tip S BRÖCKSKES D-VIERSEN L ( TYP K HV-SENSOR ( 2,0 m 0,4 m inner sheath HV-TC marking thermocouple type K thermocouple cable type K 4 x 2 x 0,20 mm Ø Not protected construction type (channel 1-4) (only protected along ) approx. 4,5 mm S BRÖCKSKES D-VIERSEN L ( Typ K HV-SENSOR ( Construction type of measuring tip according to customer s specification Routine test 8

9 1-CHANNEL HV THERMOCOUPLE CABLE Item no. L connector cable with double insulation measuring tip S BRÖCKSKES D-VIERSEN L ( TYP K HV-SENSOR ( 2,0 m 0,4 m inner sheath HV-TC marking thermocouple type K thermocouple cable type K 1 x 2 x 0,20 mm Ø Protected construction type (channel 1) (measuring tips insulated, equally protected) approx. 3,4 mm S BRÖCKSKES D-VIERSEN L ( Typ K HV-SENSOR ( Construction type of measuring tip according to customer s specification Routine test 9

10 8-CHANNEL HV PT SENSOR CABLE (4-WIRE MEASUREMENT TECHNIQUES) Item no. L connector cable with double insulation S BRÖCKSKES D-VIERSEN L ( HV Pt-Sensorleitung ( 2,0 m inner sheath HV-PT marking conductor tinned Pt 4 x 8 x 0,03 mm Ø approx. 9,3 mm S BRÖCKSKES D-VIERSEN L ( HV Pt-Sensorleitung ( Construction type according to customer s specification Routine test 10

11 2-CHANNEL HV PT SENSOR CABLE (4-WIRE MEASUREMENT TECHNIQUES) Item no. L connector cable with double insulation S BRÖCKSKES D-VIERSEN L ( HV-ANALOG ( 2,0 m inner sheath blue inner sheath orange HV-marking conductor tinned 8 x 0,03 mm² approx. 4,9 mm S BRÖCKSKES D-VIERSEN L ( HV-ANALOG ( Construction type according to customer s specification Routine test 11

12 HV ANALOG SENSOR CABLE Item no. L Item no. L inner sheath HV-AD marking conductor tinned inner sheath HV-AD marking conductor tinned AD 4 x 2 x AWG 28 AD 2 x 4 x AWG 28 approx. 7,1 mm S BRÖCKSKES D-VIERSEN CSM GmbH D-FILDERSTADT L ( HV-ANALOG ( approx. 7,2 mm S BRÖCKSKES D-VIERSEN CSM GmbH D-FILDERSTADT L ( HV-ANALOG ( S BRÖCKSKES GmbH & Co. KG Grefrather Straße b D Viersen Phone: (+49) 2162/ Fax: (+49) 2162/ info@sab-broeckskes.de CSM GmbH - Computer-Systeme-Messtechnik Raiffeisenstrasse 36 D Filderstadt Phone: (+49) 711/ Fax: (+49) 711/ info@csm.de 12/

ROESSEL SENSORS SYSTEMS SOLUTIONS. Program Overview F K. The Benchmark Name in Temperature Measurement

ROESSEL SENSORS SYSTEMS SOLUTIONS. Program Overview F K. The Benchmark Name in Temperature Measurement Program Overview The Benchmark Name in Temperature Measurement Mineral-insulated metalsheathed thermocouples ROESSEL mineral-insulated metal-sheathed thermocouples (MI- TC s) are extremely flexible and

More information

Accessories, interfaces, sensors and complete solutions.

Accessories, interfaces, sensors and complete solutions. 101101_DSsensors_EN Accessories, interfaces, sensors and complete solutions. Overview Boomerang is much more than just another temperature log system. Boomerang is a versatile and flexible monitoring and

More information

Advantages / Characteristics

Advantages / Characteristics Air to Air 50 W 30 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 70 W 36 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 75 W 30 W cooling capacity 130x109x163mm (LxBxH) 1,5 kg

More information

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing Ready-to-Use Heat Tracing Solutions for Laboratory Applications innovations in heat tracing eltherm GmbH Solutions with Electric Heat Tracing Systems eltherm GmbH is an internationally operating engineering

More information

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version) PSC-SSS-PM Series Miniature Infrared Temperature Sensors with Optional Touch Screen Display PSC-SSS-PM with touch screen display (- version) FEATURES Miniature sensing head and configurable electronics

More information

Thermo Scientific Heraeus Heating and Drying Ovens

Thermo Scientific Heraeus Heating and Drying Ovens IMLAB CENTRE D'AFFAIRES HORLOGERIE 48 RUE DES CANONNIERS 59000 LILLE Tél 03 20 55 19 11 Fax 03 20 55 20 85 www.imlab.com Thermo Scientific Heraeus Heating and Drying Ovens Quality that meets every laboratory

More information

Environmental simulation chamber for complex alternating climate profiles

Environmental simulation chamber for complex alternating climate profiles MKF series (E3.1) Environmental simulation chambers Environmental simulation chamber for complex alternating climate profiles A BINDER environmental simulation chamber of the MKF series is ideally suited

More information

ni.com/manuals For specifications, refer to the NI USB-TC01 Device Specifications document available at ni.com/manuals.

ni.com/manuals For specifications, refer to the NI USB-TC01 Device Specifications document available at ni.com/manuals. USER GUIDE NI USB-TC01 Single-Channel Thermocouple Input Module Français Deutsch 日本語한국어简体中文 ni.com/manuals The National Instruments USB-TC01 data acquisition (DAQ) device provides a Full-Speed USB interface

More information

Huminator II. Precision Humidity Generator. ww.testo.in

Huminator II. Precision Humidity Generator. ww.testo.in Huminator II Precision Humidity Generator ww.testo.in All advantages at a glance ü Wide temperature and humidity range from 5 C to 50 C and from 5%RH to 95%RH ü New touch display enables a fast and intuitive

More information

Constant climate chamber with ICH-compliant illumination

Constant climate chamber with ICH-compliant illumination KBF P series (E5.2) Constant climate chambers Constant climate chamber with ICH-compliant illumination The BINDER KBF P constant climate chamber, equipped with ICH-compliant illumination, is the expert

More information

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Climate chambers with illumination and humidity The BINDER KBWF series shines with its KBWF series (E5.2) Climate chambers with illumination Climate chambers with illumination and humidity The BINDER KBWF series shines with its homogeneous light distribution with natural illumination from

More information

Complete packages with Software and Controller

Complete packages with Software and Controller Thermoguard Basic Complete packages with Software and Controller Thermoguard Basic packages contain the software, one sensorcontroller and one sensor. The functional scope of the Thermoguard Basic software

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Food safety can be measured. Check limit values, ensure quality, comply with HACCP with measuring instruments from Testo.

Food safety can be measured. Check limit values, ensure quality, comply with HACCP with measuring instruments from Testo. Food safety can be measured. Check limit values, ensure quality, comply with HACCP with measuring instruments from Testo. Measuring solutions for the food sector Precious goods deserve the greatest care

More information

Constant climate chambers

Constant climate chambers KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.

More information

Safety vacuum drying oven for flammable solvents

Safety vacuum drying oven for flammable solvents VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with

More information

Constant climate chambers

Constant climate chambers KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.

More information

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min Heat on Air heaters from 400 Watt to 17 400 Watt Blowers from 1,45 m 3 /min to 16,5 m 3 /min BAK Thermoplastic Need-to-know Calculation of air heaters 1. Heat requirement calculation Formula: Q = m * c

More information

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440) Safety Temperature Limiter STL 50 Certified to DIN EN 14597 (replaces DIN 3440) Features M For use as: STB Protection - temperature limiter ASTB Exhaust gas - protection - temperature limiter STW Protection

More information

DataSheet. Thermocouple Logger

DataSheet. Thermocouple Logger DataSheet Thermocouple Logger For Type K, J, T & N Standard & miniature plugs Burnout response Cost-effective The Tinytag Ultra 2 Thermocouple data logger uses a thermocouple sensor for the cost-effective

More information

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture meas. according to ISO 8573 Residual oil content - particles - moisture DS 500 - the intelligent chart recorder of the next generation. The centerpiece of compressed air quality measurement is the chart

More information

DataSheet. Thermocouple Logger

DataSheet. Thermocouple Logger DataSheet Thermocouple Logger For Type K, J, T & N Standard & miniature plugs Burnout response Cost-effective The Tinytag Ultra 2 Thermocouple data logger uses a thermocouple sensor for the cost-effective

More information

Model KBF 240 Constant climate chambers with large temperature / humidity range

Model KBF 240 Constant climate chambers with large temperature / humidity range Model KBF 240 Constant climate chambers with large temperature / humidity range BENEFITS Homogeneous climate conditions thanks to APT.line technology Automatic water and wastewater management Pressure

More information

ß-Aerosolmonitor FHT 59 C

ß-Aerosolmonitor FHT 59 C Technical Specification ZT-240-1103 E page 1/11 1. FHT 59C Moving Filter Aerosol Monitor 1.1 General The FHT 59 C is a unique moving filter aerosol monitor that can operate for one year or longer without

More information

Constant climate chamber with humidity

Constant climate chamber with humidity KBF series (E5.2) Constant climate chambers Constant climate chamber with humidity The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate

More information

KMF Environmental test chamber for constant climate

KMF Environmental test chamber for constant climate SHENZHEN YIHUAXIN ELECTRNICS C.,LTD Tel:+86-755-86218000 Fax:+86-755-86218111 www.yihuaxin.net yhx@yihuaxin.net Environmental test chambers KMF 240 - Environmental test chamber for constant climate The

More information

Operating Instruction Precipitation Sensors (15189) + (15189 HL)

Operating Instruction Precipitation Sensors (15189) + (15189 HL) Features Precipitation Sensor for automatic weather stations Exchangeable, weighing tipping bucket system according to Joss- Tognini 2 cm³ (2g water) tipping bucket for precise precipitation measuring

More information

CTS Your Partner for Customised Technical Solutions

CTS Your Partner for Customised Technical Solutions How to find us: Karlsruhe Stuttgart A 8 München Exit Empfingen A 81 Haigerloch B 32 B 27 Exit Bodelshausen Rangendingen Tübingen Exit Hechingen Nord Haigerloch Hechingen Singen B 27 Rottweil Balingen Lotzenäcker

More information

VACUUM HEATING AND DRYING OVENS Gentle and safe

VACUUM HEATING AND DRYING OVENS Gentle and safe VACUUM HEATING AND DRYING OVENS Gentle and safe Quality Products Lifetime Care VACUTHERM 6000 USER FRIENDLY AS NEVER BEFORE The intelligent, modular system: three sizes and two types of heating Series

More information

OPTISENS TUR 2000 Technical Datasheet

OPTISENS TUR 2000 Technical Datasheet OPTISENS TUR 2000 Technical Datasheet Sensor for turbidity measurement in water and wastewater Rugged design for harsh applications Integrated transmitter with direct 4...20 ma output Near infrared light

More information

Accessories, interfaces, sensors and complete solutions.

Accessories, interfaces, sensors and complete solutions. 080530_DSsensors_EN Accessories, interfaces, sensors and complete solutions. Overview Boomerang is much more than just another temperature log system. Boomerang is a versatile and flexible monitoring and

More information

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment: Constant climate chambers KBF 240 (E5.2) - Constant climate chamber The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions.

More information

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15 with coupling device AGH675-7 and AGH675-7MV15 Device combination for insulation monitoring in unearthed AC, AC/DC and DC power systems (IT systems) IRDH275BM-7_D00123_03_D_XXEN/01.2017 with coupling device

More information

Constant climate chambers

Constant climate chambers Constant climate chambers KBF P 240 (E2) - Constant climate chamber for photostability tests Specialized equipment for photostability tests. Integrated cooling of fans consistently compensates for the

More information

Analog Input Module IC670ALG630

Analog Input Module IC670ALG630 1 IC670ALG630 The Thermocouple (IC670ALG630) accepts 8 independent thermocouple or millivolt inputs. Module features include: Self calibration Two data acquisition rates based on 50 Hz and 60 Hz line frequencies

More information

Constant climate chambers

Constant climate chambers KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.

More information

DIGITAL PANEL METER N20 type

DIGITAL PANEL METER N20 type DIGITAL PANEL METER N20 type USER S MANUAL 1 2 Contents 1. APPLICATION AND METER DESIGN... 5 2. METER SET... 6 3. BASIC REQUIREMENTS, OPERATIONAL SAFETY... 6 4. INSTALLATION... 7 5. SERVICE... 9 6. ERROR

More information

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 Introduction Honeywell s STT 3000 family of microprocessor based transmitters covers the full

More information

Temperature Measurement Transmitters for field mounting

Temperature Measurement Transmitters for field mounting Siemens AG 07 Overview Application The SITRANS TF can be used everywhere where temperatures need to be measured under particularly harsh conditions. For that reasons users from all industries have opted

More information

Compact Ultra Low Temperature Chamber

Compact Ultra Low Temperature Chamber Compact Ultra Low Temperature Chamber MC-712R 812R CAT.NO.E14140-Z1804 High performance and reliability come in a compact package, covers wide range of temperature testing needs, from ultra-low temperature

More information

Dew point set DS 400

Dew point set DS 400 set DS 400 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the

More information

HYDRAULIC CRIMPING TOOL

HYDRAULIC CRIMPING TOOL HYDRAULIC CRIMPING TOOL HT 120 Crimping force kn 120 488 138 5,7 This lightweight and self contained tool will accept the semi-circular slotted dies, coon to most 130 kn tools. It is particularly suitable

More information

SITRANS T temperature transmitters A broad product family for every application. sitrans

SITRANS T temperature transmitters A broad product family for every application. sitrans SITRANS T temperature transmitters A broad product family for every application sitrans The SITRANS T family High-precision, intrinsically safe, and available for a wide variety of sensors Whether you

More information

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue Product Catalogue Thermal Management Products & Accessories from STEGO successfully used worldwide for control panels and enclosures for traffic control and monitoring systems in the transport industry

More information

HPLC Column Ovens and Temperature Controllers

HPLC Column Ovens and Temperature Controllers HPLC Column Ovens and Controllers Improve your separation performance today! Accurate temperature control of your HPLC columns will improve the reproducibility of your results. Operating at increased temperatures

More information

ULTRA.GUARD ultra low temperature freezer

ULTRA.GUARD ultra low temperature freezer UF V series 700 Ultra low temperature freezers ULTRA.GUARD ultra low temperature freezer The new BINDER ULTRA.GUARD ultra low temperature freezer ensures safe long-term storage of samples at -86 C. This

More information

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY S E C T I O N 10 C O N T E N T S N A V I G A T I O N Introduction.................... 10.2 Portable Meters................. 10.3 Transmitter..................... 10.9 Probes......................... 10.10

More information

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1 emperature Multi-Input Device for Cabinet Installation Features Assembly For 8 temperature or analog sensors Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus

More information

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine Thermo Scientific Round Top Hotplate Stirrers Make safety and accuracy part of your routine Thermo Scientific Round Top Hotplate Stirrers Our portfolio of roundtop hotplates, stirrers and stirring hotplates

More information

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291 TI01198C/07/EN/03.16 71326008 Products Solutions Services Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291 Portable multiparameter device for Memosens ph, conductivity and oxygen

More information

It offers easy installation and the possibility for fast exchange of the sensor unit for service purposes.

It offers easy installation and the possibility for fast exchange of the sensor unit for service purposes. Series Humidity / Temperature Transmitter for Industriell Applications Calculation of Dew Point and Frost Point Temperature The series stands for multifunctionality, highest accuracy, easy mounting and

More information

Environmental Chambers

Environmental Chambers Temperature (& ) Chambers Dimensions (TH-G / TH-I / TC-G series) 115 Models Capacity W D H A B TH-G TH-I TC-G TH-G TC-G 180L (6.4cu ft) 1025mm (40.4 ) 1035mm (40.7 ) 1530mm (60.2 ) 450mm (17.7 ) 1230mm

More information

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring Data Sheet 907021 Page 1/9 Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring For measuring relative air humidity, temperature, and fresh

More information

Product overview CREATING MEASUREMENT SOLUTIONS

Product overview CREATING MEASUREMENT SOLUTIONS Product overview CREATING MEASUREMENT SOLUTIONS TEMPERATURMESSTECHNIK CERTIFICATIONS Certificate DIN EN ISO 9001 : 2015 ESD-Certificate DELIVERY PROGRAMME HUMIDITY MEASURING TECHNOLOGY Humidity sensors...

More information

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700 Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700 02 Ultra low temperature freezers for long-term storage at -86 C 03 LONG-TERM STORAGE OF SAMPLES Always the right design

More information

ECL Comfort 300 / V a.c. and 24 V a.c.

ECL Comfort 300 / V a.c. and 24 V a.c. Data sheet ECL Comfort 300 / 301 230 V a.c. and 24 V a.c. Application The ECL Comfort 300 / 301 is an electronic temperature controller which can be loaded with selected applications by means of an ECL

More information

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring Data Sheet 907021 Page 1/8 Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring For measuring relative air humidity, temperature, and carbon dioxide concentration

More information

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety USE IN HAZARDOUS LOCATIONS Fieldbus-Independent I/O for Hazardous Areas In many plants across the chemical and petrochemical industries, as

More information

50 - WMS // Straight resistance thermometers with a metal thermowell and a built-in measurement insert

50 - WMS // Straight resistance thermometers with a metal thermowell and a built-in measurement insert 50 - WMS // Straight resistance thermometers with a metal thermowell 50-WMS and a built-in measuring insert The 50-WMS product group comprises ready-to-install large and small straight resistance thermometers

More information

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS Portable Industrial Chilled Mirror Hygrometer Fundamental drift free humidity measurement Integral frost/dew point measuring head Internal sample pump Optimal Response Injection System for fast measurement

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 E25.0.01.6C-14 Data logger for temperature as of version V7.0 Operating Manual EASYLOG 40K EASYLOG 40KH EASYLOG 40KH-E300 EASYLOG 40KH-E600 EASYLOG 40KH-GOF EASYLOG 40K EASYLOG 40KH WEEE-Reg.-Nr. DE93889386

More information

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,

More information

Thermostats designed

Thermostats designed Thermostats designed to work perfectly 1 High-precision temperature control solutions IKA is proud to introduce several highprecision temperature control systems from +20 to +250 o C. This wide product

More information

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800 SENSORS & SYSTEMS Authority in Displacement Measurement CCD-Precision high accuracy and resolution compact sensor design 5 khz frequency N ILD 1800 TRIANGULATOI PRINCIPLE OPTO NCDT Intelligent Laser-Optical

More information

HPS-C-MULTI 6. Hotrunner Controllers. Operating manual. Valid for item numbers:

HPS-C-MULTI 6. Hotrunner Controllers. Operating manual. Valid for item numbers: Valid for item numbers: HPS-C-MULTI 6: 69010.306 (6-zone) 69010.312 (12-zone) 69010.324 (24-zone) 69010.336 (36-zone) HPS-C-MULTI 6 Hotrunner Controllers Operating manual HPS-C-MULTI 6 with WIRE TEST (WT):

More information

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800 SENSORS & SYSTEMS Authority in Displacement Measurement CCD-Precision high accuracy and resolution compact sensor design 5 khz frequency N ILD 1800 TRIANGULATOI PRINCIPLE OPTO NCDT Intelligent Laser-Optical

More information

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001 SLATE Base Module R8001A1001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can

More information

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories Product Catalogue Content Heating Small semiconductor Heater HGK 047 Series 3 Semiconductor Heater HG 040 Series 4 Semiconductor Heater HG 140 Series 5 Semiconductor Heater CS 060 Series 6 Semiconductor

More information

Temperature Data Logging

Temperature Data Logging . Temperature Data Logging Making the right choice with a Data Acquisition System There are many ways to make temperature measurements. The simplest method is to insert a temperature probe into a device

More information

Energy Saving Methods for Transformer Oven

Energy Saving Methods for Transformer Oven Energy Saving Methods for Transformer Oven J.A.Vitharana, N.H.K.L.Sirisena, K.R.S.Dematagolla, J.A.I.T.Jagoda Supervisors: Prof.J.R.Lucas, Prof.P.D.C.Wijayathunga, Mr.Kosala Gunwardhana, Mr. Rukshika Pathberiya

More information

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC Technical Concept Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC Technical Concept Plenum Integrated Filter Fan Product Description The Plenum Integrated Filter Fan (PIFF) is a fan filter unit with integrated

More information

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world! THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world! FOR ALL YOUR TEMPERATURE AND HUMIDITY CONTROLS, PRODUCT TRACKING, TRANSPORT, STORAGE CONTROLS, HACCP! Small, rugged,

More information

EL-USB-1-LCD Temperature Data Logger with LCD

EL-USB-1-LCD Temperature Data Logger with LCD 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 EL-USB-1-LCD Temperature Data Logger with LCD Visit us at www.testequipmentdepot.com ORDERING INFORMATION Standard Data

More information

Plant growth chambers

Plant growth chambers Plant growth chambers KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions The closest thing to natural conditions. Making use of the multifaceted programming options, we achieve perfect

More information

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range The BINDER MKFT series environmental simulation chamber for low temperature

More information

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number Worldwide Supplier of Safety Solutions GfG Instrumentation 1194 Oak Valley Drive #20 Phone: 734-769-0573 Fax: 734-769-1888 E-Mail: info@gfg-inc.com Internet: www.gfg-inc.com GMA 301 Operation Manual Part

More information

SIL2-Interface/ -Signal Conditioners Series DuoTec

SIL2-Interface/ -Signal Conditioners Series DuoTec SIL2-Interface/ -Signal Conditioners Series DuoTec Certified according IEC 61508/ 61511 SIL2 DIN-Rail- and 19 -Mounting Since 1970 - Mütec Instruments GmbH Introduction To achieve a maximum safety in production

More information

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone

More information

Parameterisable compact fault annunciator with permanent display

Parameterisable compact fault annunciator with permanent display Parameterisable compact fault annunciator with permanent display FSM 10 Drop-flap fault annunciator 31.08.2010 Permanent display even on power failure Compact module for 10 alarms Supply and alarm signal

More information

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Plasma Freezer with air circulation TC 516 acc. to DIN 58375 These blood plasma storage cabinets are designed for DIN - compliant storage of already frozen blood plasma bags. External Dimensions: B = 600 mm D = 780 mm H = 2000 mm Internal Dimensions: B = 500 mm

More information

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation Compact design for personal use Ready to network with your computer. Introducing a new lineup of our Bench-top Type (& Humidity) Chamber Series. Our latest models achieve superb performance in a compact

More information

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery 99 Washington Street Melrose,

More information

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Model KMF 115 Constant climate chambers with expanded temperature / humidity range Model KMF 115 Constant climate chambers with expanded temperature / humidity range BENEFITS Homogeneous climate conditions thanks to APT.line technology Automatic water and wastewater management Humidification

More information

SecuriSens d-list Product Catalogue 2015

SecuriSens d-list Product Catalogue 2015 SecuriSens d-list Product Catalogue 2015 Content 1. Processor Units... 5 2. Cable d-list... 7 3. Single Sensor d-list... 8 4. Accessories d-list... 9 5. ATEX components d-list... 13 6. Spare Parts d-list...

More information

Bench-Top Type Temperature (& Humidity) Chamber

Bench-Top Type Temperature (& Humidity) Chamber Bench-Top Type Temperature (& Humidity) Chamber SHSU CAT.NO.E01111-M102 Compact design for personal use, to network with your computer. The Bench-top Type Temperature (& Humidity) Chamber Series features

More information

Product Data Sheet Adsorption Dryer DPS (A)

Product Data Sheet Adsorption Dryer DPS (A) Version: 1.0.5 Author: Tassilo Tappe Date:13.07.2012 Field of application Adsorption dryers of the DPS series are designed for drying compressed air and nitrogen to pressure dew points of -25 C to -70

More information

ECL Comfort V a.c. and 24 V a.c.

ECL Comfort V a.c. and 24 V a.c. Data sheet ECL Comfort 300 230 V a.c. and 24 V a.c. Application The ECL Comfort 300 is an electronic temperature controller which can be loaded with selected applications by means of an ECL Card. The ECL

More information

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series Standard-Incubators Avantgarde.Line BD BF series Classic.Line B BD BF series Solid.Line BD-S series EN PRODUCT SELECTION INCUBATORS Classic.Line Classic.Line Avantgarde.Line Solid.Line Classic.Line Avantgarde.Line

More information

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME. PROCESS AUTOMATION K-SYSTEM THE MOST TRUSTED NAME PROCESS AUTOMATION PROTECTING YOUR PROCESS THE SYSTEM ELECTRONICS Availability: Power feed modules for a simplex or redundant supply on Power Rail Transmission

More information

METPOINT THE COMPLETE RANGE OF PRECISION CONTROL DEVICES FOR COMPRESSED AIR DEW POINT, FLOW, AND LEAKAGE

METPOINT THE COMPLETE RANGE OF PRECISION CONTROL DEVICES FOR COMPRESSED AIR DEW POINT, FLOW, AND LEAKAGE THE COMPLETE RANGE OF PRECISION CONTROL DEVICES FOR COMPRESSED AIR DEW POINT, FLOW, AND LEAKAGE METPOINT DPM DEW POINT MONITORS Moisture in compressed air can cause severe damage. Malfunctions in a production

More information

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Model KMF 720 Constant climate chambers with expanded temperature / humidity range Model KMF 720 Constant climate chambers with expanded temperature / humidity range BENEFITS Homogeneous climate conditions thanks to APT.line technology Automatic water and wastewater management Humidification

More information

Process Instrumentation. Battery-powered, reliable and cost efficient. SITRANS F M MAG 8000 water meter for long-term accuracy. siemens.

Process Instrumentation. Battery-powered, reliable and cost efficient. SITRANS F M MAG 8000 water meter for long-term accuracy. siemens. Process Instrumentation Battery-powered, reliable and cost efficient. SITRANS F M MAG 8000 water meter for long-term accuracy. siemens.com/mag8000 The water meter of choice for distribution, billing and

More information

TSXAEY1614C analog input module - 16 inputs - thermocouple - 16 bits

TSXAEY1614C analog input module - 16 inputs - thermocouple - 16 bits Characteristics analog input module - 16 inputs - thermocouple - 16 bits Product availability : Stock - Normally stocked in distribution facility Price* : 5684.45 USD Main Range of product Product or component

More information

Concise catalogue Water-Industry

Concise catalogue Water-Industry 2008 Concise catalogue Water-Industry One-channel instruments to measure ph, EC, DO and free chlorine, panel and wall-mounting version. Transmitters - controllers very easy to utilize, the customer does

More information

Isolated Thermocouple Module

Isolated Thermocouple Module User Manual for the HE693THM665, HE693THM666, HE693THM667, HE693THM668 Isolated Thermocouple Module Twelfth Edition 19 April 2004 PREFACE 19 APR 2004 PAGE 3 PREFACE This manual explains how to use the

More information

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter BA 104R/24/ae/10.03 itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter Operating instructions RTD TC TMT 187 TMT 188 Temperature head transmitter Safety message # Warning! Instructions and

More information

EL-USB-1-LCD Temperature Data Logger with LCD

EL-USB-1-LCD Temperature Data Logger with LCD Temperature Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery EL-USB-1-LCD BAT 3V6 1/2AA FEATURES measurement range USB interface

More information

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER MODEL AH3 7 P - - A AH3000 series conforming to CE, UL and CSA are 180mm pen type hybrid recorders with a simultaneous display of multi-channel data,

More information

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012372 / 03.2015 isopv

More information

METROTEC Systeme zur Messung und Regelung von Sauerstoff

METROTEC Systeme zur Messung und Regelung von Sauerstoff Systeme zur Messung und Regelung von Sauerstoff U15-DIGITAL Oxygen Measuring and Control Device U15 Series Measuring module *** Version 1.1 *** Our management system is certified according to DIN EN ISO

More information