PACKAGED SOLUTIONS FOR FIRE PROTECTION, PLUMBING AND BUILDINGS

Size: px
Start display at page:

Download "PACKAGED SOLUTIONS FOR FIRE PROTECTION, PLUMBING AND BUILDINGS"

Transcription

1 FIRE PROTECTION BUILDING SERVICE PLUMBING HYDRAULIC SMOOTHFLOW Tel: Fax: PACKAGED SOLUTIONS FOR FIRE PROTECTION, PLUMBING AND BUILDINGS

2 Contents Products Page 1 Gate Valves 1 2 Butterfly Valves 2 3 Check Valves 4, 5,6 4 Ball Valves 6 5 solenoid valves 24V 6 6 Sprinkler Flexi Droppers Grooved Fittings Galvanised Malleable Fittings Escutcheons For Sprinkler Heads Sprinkler Heads --- Upright And Pendent Sprinkler Heads --- Horizontal Sidewall Alarm Valve Water Motorized Alarm Bell (Water Gong) Landing Valve Booster Heads Storz Hose Reel Cabinet For Hose Reel Cabinets For Sprinkler Control Valve Galvanised Steel Pipe Sprinkler Pipes Fabricated Pipes mm Booster Assembly Hydrant Riser Fittings For Building/Plumbing Cutting Service Pear Pipe Hangers Thread Rods, Bolts And Nuts Strut And Pipe Clamp Pressure Gauges Pad Lock Stand For Hose Reel Cabinet Stand For Hose Reel Pumps For Building Services 95

3 VALVES SMOOTHFLOW AUSTRALIA GATE VALVE RESILIENT WEDGE, RISING STEM, OS&Y, 300PSI, (ITEM NO.: G) FEATURES Valves comply with AWWA C515. Working pressure: 300PSI; working temperature: 0.6 o C to 52 o C. OS&Y, rising stem grooved ends for fire services. CONSTRUCTION The handwheel is attached to the yoke by a heavier nut. Stem is sealed by high quality graphite. One brass plug screwed on body. Fusion boned epoxy coated interior and exterior. MATERIALS LIST PART NAME MATERIAL ASTM SPEC. Body Ductile iron A Wedge Ductile iron with EPDM vulcanised Disc nut Stainless steel AISI 304 Stem Stainless steel AISI 420 Bonnet Ductile iron A Gasket EPDM Commercial Packing Graphite Commercial Gland Ductile iron A Yoke nut Bronze ASTM B62 Handwheel Ductile iron A Nut for handwheel Ductile iron A NPT plug Brass B16, C36000 Bolt & nut on gland Stainless steel AISI 316 Bolt on bonnet flange Carbon steel A307 B DIMENSIONS SIZE 65mm (2.5 ) 80mm (3 ) 100mm (4 ) 150mm (6 ) ALL DIMENSIONS IN MILLIMETRES 200mm 250mm 300mm (8 ) (10 ) (12 ) OD L H (OPEN) H (CLOSE) D Tel: info@smoothflow.com.au Page 1

4 VALVES SMOOTHFLOW AUSTRALIA BUTTERFLY VALVE GEAR OPERATED, 300PSI, GROOVED ENDS (ITEM NO ) MATERIAL SPECIFICATIONS VALVE PART NAME Material EN Spec. ASTM Spec. Body Ductile iron En-JS1050 A Disc Ductile iron, EPDM coated En-JS1050 A Shaft Stainless steel BS S29 AISI 431 Bush Brass 2874 CZ 124 B16 C36000 Housing Cast iron EN-JL 1040 A126 Class B GEAR OPERATOR Cover Cast iron EN-JL 1040 A126 Class B Worm gear Brass CuZn39Pb3 B16 C36000 Worm Stainless steel AISI 420 BS S37 Handwheel Cast iron EN-JL 1040 A126 Class B Note: UL approved. Top Flanges Comply with ISO 5211/1. Groove dimensions comply with Metric or AWWA C606 Standard. INSTALLATION SHEET FOR GEAR OPERATOR WITH TAMPER SWITCH Butterfly valves are provided with internal supervisory position switches. The tamper switch operates by a cam connected to the valve stem. The switch will change position and close within two (2) full turns of the hand wheel from the fully open position. SWITCH #1: SWITCH #2: For connection to the supervisory circuit Auxiliary switch connected. Normal close: 2 Yellow Normal close: 1 Blue Normal open: 2 Red Normal open: 1 Orange Common: 2 White Common: 1 Black Ground Lead: 1 Green Tel: info@smoothflow.com.au Page 2

5 VALVES SMOOTHFLOW AUSTRALIA BUTTERFLY VALVE Continuous DIMENSIONS (mm) SIZE A B D E C F G H L M DN DN DN DN DN DN DN DN Tel: info@smoothflow.com.au Page 3

6 VALVES SMOOTHFLOW AUSTRALIA CHECK VALVE SWING TYPE, 300PSI, GROOVED ENDS (ITEM NO ) FEATURES Swing type, with FM/UL Approval Working pressure: 300PSI; Working temperature: -10 o C to 120 o C. CONSTRUCTION Seating type is resilient material to bronze seat construction. Grooved dimensions comply with Metric or AWWA C606 Fusion boned epoxy coated interior and exterior. MATERIAL LIST PART NAME MATERIAL ASTM SPEC. Body Ductile iron A Body seat Bronze ASTM B62 Disc DI with rubber coated DI + EPDM Spindle Stainless steel AISI 316 Spring Stainless steel AISI 304 Plug Stainless steel AISI 304 Washer Rubber EPDM DIMENSIONS SIZE 65mm (2.5 ) 80mm (3 ) 100mm (4 ) 150mm (6 ) ALL DIMENSIONS IN MILLIMETRES 200mm 250mm 300mm (8 ) (10 ) (12 ) OD L H Tel: info@smoothflow.com.au Page 4

7 WAFER CHECK VALVE SMOOTHFLOW AUSTRALIA MATERIALS PART Body Spring Disc Seat Shafts Gasket MATERIAL Ductile Iron 304SS 304SS NBR 304SS NBR WAFER CHECK VALVE DOUBLE DISC SF CODE SIZE L D V-CV-WD V-CV-WD V-CV-WD V-CV-WD V-CV-WD TEL: INFO@SMOOTHFLOW.COM.AU Page 5

8 ACCESSORIES FOR FIRE PROTECTION SMOOTHFLOW AUSTRALIA Lockable Brass ball Valve Pressure Rating: 25bar Lockable for fire use F/F BSP Available from ¼ to 2 Mini Brass ball Valve Pressure Rating: 25bar 304 SS M/F BSP Available in 8mm, 10mm and 15mm Check Valve spring type and swing type Pressure Rating: 16 bar F/F BSP Available from 15mm to 50mm Solenoid Valve 24V Pressure Rating: 16 bar F/F BSP 24V DC Available in 15mm, 20mm and 25mm TEL: info@smoothflow.com.au Page 6

9 Tel: page 7

10 PRODUCT DATA SHEET Product Description EH-8100, DN25, Braided Flexible Sprinkler Hose with Threaded End Fittings, For Use in Commercial Suspended Ceilings, Construction Consists of a stainless steel flexible hose assembly with one inlet nipple, one outlet reducer, with one 620mmL square bar, one central bracket, and two end brackets. Item Parts Materials 1 Reducer SPCC/SUS304 2 Seal Ring SUS304 3 Bellows SUS304 4 Wire Braids SUS304 5 Nipple SPCC/SUS304 Specification Size EH A EH A EH A EH A EH A EH A L(mm) FEATURES 1. Non-pollution: Stainless steel construction requires without painting or epoxy coating on side. What the most important is that it is stainless to sure in case the fire break out the sprinkler system works without blockage. That s why FM requires flexible hose linking with sprinkler head. 2. Simple Installation: Take a quarter of conventional system to install, reduced man power and labour costs. 3. Good Flexibility: Eliminate potential leaks and protect gel seal during seismic activity, Allow the independent way between ceiling grids and main water pipe. Eliminate ceilings stress and leak due to misaligned hard-piped installation 4. Easy Relocation: No downtime while sprinkler heads are being moved to accommodate tool or floorplane configuration. Conformance Criteria and Evaluation The EH-8100, braided flexible sprinkler hose has been evaluated and verified as conforming to the relevant requirements of the following: 1. FM Approvals, Approval standard for Flexible Sprinkler Hose With Threaded End Fittings, Class 1637, Dated February FM Project ID: Tel: info@smoothflofire.com.au page 8

11 Technical Specification The following details are a representative extract of the technical specification for the EH-8100 braided flexible sprinkler hose and may be subject to change. Complete and current details should be determined from the manufacturer s technical manual. The flexible sprinkler hoses are to be installed according to the manufacture s directives. Model BSP Inch (mm) k-factor Minimum Bend Radius Inch (mm) Number of Bends Rated Working Pressure psi (kpa) Hose Assembly length in (mm) Equivalent Length of 1 in. Schedule 40 Pipe, ft (m) E ½ (15) (150) (1380) 24 (610) 18.2 (5.5) E ½ (15) (150) (1380) 23.0 (7.0) E ½ (15) (150) (1380) 40 (1015) 25.7 (7.8) E ½ (15) (150) (1380) 48 (1220) 29.0 (8.8) E ½ (15) (150) (1380) 60 (1525) 37.0 (10.4) E ½ (15) (150) (1380) 72 (1830) 38.5 (11.7) Tel: info@smoothflofire.com.au page 9

12 GROOVED FITTINGS SMOOTHFLO FIRE RIGID COUPLING CODE Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) Bolts Overall Dimensions (mm) Ф L H Approx. Weight (KG) GCOR M10x GCOR M10x GCOR M10x GCOR M10x GCOR M10x GCOR M12x GCOR M12x GCOR M12x GCOR M12x GCOR M16x GCOR M22x FLEXIBLE COUPLING CODE Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) Max Angle x Deflection Overall Dimensions (mm) Ф L H Approx. Weight (KG) GCOF x GCOF x GCOF x GCOF x GCOF x GCOF x GCOF x GCOF x GCOF x GCOF x GCOF x TEL: INFO@SMOOTHFLOFIRE.COM.AU Page 10

13 GROOVED FITTINGS SMOOTHFLO FIRE REDUCING FLEXIBLE COUPLING CODE Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) Bolts Overall Dimensions (mm) Ф L H Approx. Weight (KG) GCORF x x M10x GCORF x x M12x GCORF x x M12x GCORF x x M12x GCORF x x M12x GCORF x x M12x GCORF x x M12x GCORF x x M12x GCORF x x M12x GCORF x x M16x TEL: INFO@SMOOTHFLOFIRE.COM.AU Page 11

14 GROOVED FITTINGS SMOOTHFLO FIRE 90 o ELBOW CODE Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) L Approximate Weight (KG) GELN GELN GELN GELN GELN GELN GELN GELN GELN GELN GELN o ELBOW CODE Pipe DN (mm) Pipe OD (mm) Rated Pressure (kpa) L Approximate Weight (KG) GELF GELF GELF GELF GELF GELF GELF GELF GELF GELF GELF TEL: INFO@SMOOTHFLOFIRE.COM.AU Page 12

15 GROOVED FITTINGS SMOOTHFLO FIRE 22.5 o ELBOW CODE Pipe DN (mm) Pipe OD (mm) Rated Pressure (kpa) L Approximate Weight (KG) GELT GELT GELT GELT GELT GELT GELT GELT GELT o ELBOW CODE Pipe DN (mm) Pipe OD (mm) Rated Pressure (kpa) L Approximate Weight (KG) GELE GELE GELE GELE GELE GELE TEL: INFO@SMOOTHFLOFIRE.COM.AU Page 13

16 GROOVED FITTINGS SMOOTHFLO FIRE STANDARD TEE CODE Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) L Approximate Weight (KG) GTEES GTEES GTEES GTEES GTEES GTEES GTEES GTEES GTEES GTEES REDUCING TEE (GROOVED ENDS) CODE Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) L Approximate Weight (KG) GTRG x x GTRG x x GTRG x x GTRG x x GTRG x x GTRG x x GTRG x x GTRG x x GTRG x x GTRG x x GTRG x x GTRG x x TEL: INFO@SMOOTHFLOFIRE.COM.AU Page 14

17 GROOVED FITTINGS SMOOTHFLO FIRE REDUCING TEE (THREADED SMALL END) CODE Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) L1 (big ends) L2 (small end) Approximate Weight (KG) GTRT x 25BSP x BSP GTRT x 32BSP x BSP GTRT x 40BSP x BSP GTRT x 50BSP x BSP GTRT x 65BSP x BSP GTRT x 80BSP x BSP GTRT x 32BSP x BSP GTRT x 40BSP x BSP GTRT x 50BSP x BSP GTRT x 65BSP x BSP GTRT x 80BSP x BSP GTRT x 50BSP x BSP GTRT x 65BSP x BSP GTRT x 80BSP x BSP STANDARD CROSS CODE Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) L Approximate Weight (KG) GCRS GCRS GCRS GCRS GCRS GCRS GCRS GCRS TEL: INFO@SMOOTHFLOFIRE.COM.AU Page 15

18 GROOVED FITTINGS SMOOTHFLO FIRE REDUCING CROSS (THREADED) CODE Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) L1 L2 Approximate Weight (KG) GCRT x 25BSP GCRT x 32BSP GCRT x 40BSP GCRT x 50BSP GCRT x 25BSP GCRT x 32BSP GCRT x 40BSP GCRT x 50BSP GCRT x 65BSP GCRT x 80BSP GCRT x 50BSP GCRT x 65BSP GCRT x 80BSP REDUCING CROSS (GROOVED) Code Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) L Approximate Weight (KG) GCRG x x GCRG x x GCRG x x GCRG x x GCRG x x GCRG x x GCRG x x GCRG x x GCRG x x GCRG x x GCRG x x GCRG x x TEL: INFO@SMOOTHFLOFIRE.COM.AU Page 16

19 GROOVED FITTINGS SMOOTHFLO FIRE MECHANICAL TEE (GROOVED) Code Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) Max Hole Cutting Ф L K H Approximate Weight (KG) GMET x x GMET x x GMET x x GMET x x GMET x x GMET x x GMET x x GMET x x GMET x x GMET x x GMET x x GMET x x MECHANICAL TEE (U-BOLT, THREADED) Code Pipe DN (mm) Rated Pressure (KPA) Pipe OD (mm) Max Hole Cutting U BOLT SIZE A B C Approximate Weight (KG) GUMT x 15BSP M10 x GUMT x 15BSP M10 x GUMT x 20BSP M10 x GUMT x 25BSP M10 x GUMT x 15BSP M10 x GUMT x 20BSP M10 x GUMT x 25BSP M10 x GUMT x 15BSP M10 x GUMT x 20BSP M10 x GUMT x 25BSP M10 x GUMT x 15BSP M10 x GUMT x 20BSP M10 x GUMT x 25BSP M10 x TEL: INFO@SMOOTHFLOFIRE.COM.AU Page 17

20 GROOVED FITTINGS SMOOTHFLO FIRE MECHANICAL TEE (THREAD) Code Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) Max Hole Cutting Ф L K H Approximate Weight (KG) GMTT x 25BSP GMTT x 25BSP GMTT x 32BSP GMTT x 40BSP GMTT x 50BSP GMTT x 25BSP GMTT x 32BSP GMTT x 40BSP GMTT x 50BSP GMTT x 25BSP GMTT x32bsp GMTT x 40BSP GMTT x 50BSP GMTT x 65BSP GMTT x 80BSP GMTT x 25BSP GMTT x 32BSP GMTT x 40BSP GMTT x 50BSP GMTT x 65BSP GMTT x 80BSP GMTT x 25BSP GMTT x 32BSP GMTT x 40BSP GMTT x 50BSP GMTT x 65BSP GMTT x 80BSP GMTT x 100BSP TEL: INFO@SMOOTHFLOFIRE.COM.AU Page 18

21 GROOVED FITTINGS SMOOTHFLO FIRE CONCENTRIC REDUCER (GROOVED) Code Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) L Approximate Weight (KG) GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x GCRE x x TEL: INFO@SMOOTHFLOFIRE.COM.AU Page 19

22 GROOVED FITTINGS SMOOTHFLO FIRE CONCENTRIC REDUCER (FEMALE THREADED) Code Pipe DN (mm) Pipe OD (mm) Rated Pressure (kpa) L Approximate Weight (KG) GCRT x x 25BSP GCRT x x 32BSP GCRT x x 40BSP GCRT x x 25BSP GCRT x x 32BSP GCRT x x 40BSP GCRT x x 50BSP GCRT x x 25BSP GCRT x x 32BSP GCRT x x 40BSP GCRT x x 50BSP GCRT x x 25BSP GCRT x x 50BSP GCRT x x 65BSP GCRT x x 25BSP GCRT x x 50BSP TEL: INFO@SMOOTHFLOFIRE.COM.AU Page 20

23 GROOVED FITTINGS SMOOTHFLO FIRE ECCENTRIC REDUCER (GROOVED) Code Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) L Approximate Weight (KG) GERE x x GERE x x GERE x x GERE x x GERE x x GERE x x GERE x x TEL: INFO@SMOOTHFLOFIRE.COM.AU Page 21

24 GROOVED FITTINGS SMOOTHFLO FIRE FLANGE ADAPTOR (GROOVED) CODE Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) Do L n-ф GFAG Ф18 Approximate Weight (KG) GFAG Ф18 GFAG Ф GFAG Ф GFAG Ф GFAG Ф GFAG Ф GFAG Ф GFAG Ф FLANGE ADAPTOR (GROOVED) Drilling: Table E CODE Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) Do L n-ф GFAE Ф18 Approximate Weight (KG) GFAE Ф18 GFAE Ф18 GFAE Ф18 GFAE Ф18 GFAE Ф22 GFAE Ф22 TEL: INFO@SMOOTHFLOFIRE.COM.AU Page 22

25 GROOVED FITTINGS SMOOTHFLO FIRE DIN FLANGE (GROOVED) CODE Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) Do L n-ф Approximate Weight (KG) GFAG Ф GFAG Ф GFAG Ф GROOVED END CAP CODE Pipe DN (mm) Pipe OD (mm) Rated Pressure (KPA) L Approximate Weight (KG) GCAP GCAP GCAP GCAP GCAP GCAP GCAP GCAP GCAP GCAP GROOVE-THREAD SPIGOT CODE Pipe DN (mm) Pipe OD (mm) Rated Pressure (kpa) GSPI x 32BSP GSPI x 40BSP GSPI x 50BSP GSPI x 65BSP GSPI x 80BSP GSPI x 100BSP L TEL: INFO@SMOOTHFLOFIRE.COM.AU Page 23

26 GALVANIZED MALLEABLE FITTINGS SMOOTHFLO FIRE SPECIFICATIONS STANDARD AND DIMENSIONS: BS EN10242, BS143 & 1256 MATERIAL: ASTM A-197, ASTM47 THREADS: The threads are cut according to AS / ISO7/1. Internal female threads tapered; external threads tapered. LEAK TEST PRESSURE: complying with the standard EN Hydrostatic pressure test for individual fitting is subject to a minimal pressure of 2070kpa FM/UL APROVAL: All galvanized malleable fittings have FM/UL approval certificates. GALVANIZED MALLEABLE F/F ELBOW 90 DEGREE (ITEM NO. 90) UL APPROVAL SIZE APP. WEIGHT CODE H (mm/inch) (kg/pc) MELE06 6 (1/8 ) MELE08 8 (1/4 ) MELE10 10 (3/8 ) MELE15 15 (1/2 ) MELE20 20 (3/4 ) MELE25 25 (1 ) MELE32 32 (1-1/4 ) MELE40 40 (1-1/2 ) MELE50 50 (2 ) MELE65 65 (2-1/2 ) MELE80 80 (3 ) MELE (4 ) GALVANIZED MALLEABLE F/F REDUCING ELBOW 90 DEGREE (ITEM NO. 90R) UL APPROVAL CODE SIZE (mm) H L App W (kg/pc) MELE x MELR x MELR x MELR x MELR x MELR x MELR x MELR x MELR x MELR x MELR x MELR x MELR x MELR x MELR x MELR x MELR x MELR x MELR x Tel: info@smoothflopumps.com.au page 24

27 GALVANIZED MALLEABLE FITTINGS GALVANIZED MALLEABLE M-F ELBOW 90 DEGREE (ITEM NO. 92) SMOOTHFLO FIRE UL APPROVAL CODE SIZE (mm) H L App. W Kg/pc MMME06 6 (1/8 ) MMME08 8 (1/4 ) MMME10 10 (3/8 ) MMME15 15 (1/2 ) MMME20 20 (3/4 ) MMME25 25 (1 ) MMME32 32 (1-1/4 ) MMME40 40 (1-1/2 ) MMME50 50 (2 ) MMME65 65 (2-1/2 ) MMME80 80 (3 ) MMME (4 ) GALVANIZED MALLEABLE F-F ELBOW 45 DEGREE (ITEM NO. 120) UL APPROVAL CODE SIZE (mm) H APP. WEIGHT (kg/pc) MELF06 6 (1/8 ) MELF08 8 (1/4 ) MELF10 10 (3/8 ) MELF15 15 (1/2 ) MELF20 20 (3/4 ) MELF25 25 (1 ) MELF32 32 (1-1/4 ) MELF40 40 (1-1/2 ) MELF50 50 (2 ) MELF65 65 (2-1/2 ) MELF80 80 (3 ) MELF (4 ) GALVANIZED MALLEABLE HEXGAON NIPPLE (ITEM NO. 280) UL APPROVAL CODE SIZE (mm) H APP. WEIGHT (kg/pc) MNIP06 6 (1/8 ) MNIP08 8 (1/4 ) MNIP10 10 (3/8 ) MNIP15 15 (1/2 ) MNIP20 20 (3/4 ) MNIP25 25 (1 ) MNIP32 32 (1-1/4 ) MNIP40 40 (1-1/2 ) MNIP50 50 (2 ) MNIP65 65 (2-1/2 ) MNIP80 80 (3 ) MNIP (4 ) Tel: info@smoothflopumps.com.au page 25

28 GALVANIZED MALLEABLE FITTINGS SMOOTHFLO FIRE GALVANIZED MALLEABLE HEXGAON REDUCING NIPPLE (ITEM NO. 245) UL APPROVAL CODE SIZE (mm) H APP. WEIGHT (kg/pc) MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x MNIR x GALVANIZED MALLEABLE EQUAL TEE (ITEM NO. 130) UL APPROVAL CODE SIZE (mm) H APP. WEIGHT (kg/pc) MTEQ06 6 (1/8 ) MTEQ08 8 (1/4 ) MTEQ10 10 (3/8 ) MTEQ15 15 (1/2 ) MTEQ20 20 (3/4 ) MTEQ25 25 (1 ) MTEQ32 32 (1-1/4 ) MTEQ40 40 (1-1/2 ) MTEQ50 50 (2 ) MTEQ65 65 (2-1/2 ) MTEQ80 80 (3 ) MTEQ (4 ) Tel: info@smoothflopumps.com.au page 26

29 GALVANIZED MALLEABLE FITTINGS SMOOTHFLO FIRE GALVANIZED MALLEABLE HEXGAON REDUCING TEE (ITEM NO. 130R) UL APPROVAL CODE SIZE (mm) A H APP. WEIGHT (kg/pc) MTER x 10 x MTER x 10 x MTER x 15 x MTER x 15 x MTER x 15 x MTER x 15 x MTER x 15 x MTER x 20 x MTER x 20 x MTER x 20 x MTER x 20 x MTER x 25 x MTER x 25 x MTER x 25 x MTER x 25 x MTER x 25 x MTER x 25 x MTER x 25 x MTER x 32 x MTER x 32 x MTER x 32 x MTER x 32 x MTER x 32 x MTER x 32 x MTER x 40 x MTER x 40 x MTER x 40 x MTER x 40 x MTER x 40 x MTER x 40 x MTER x 50 x MTER x 50 x MTER x 50 x MTER x 50 x MTER x 50 x MTER x 50 x MTER x 65 x MTER x 65 x MTER x 65 x MTER x 65 x MTER x 80 x MTER x 80 x MTER x 80 x MTER x 80 x MTER x 80 x MTER x 100 x MTER x 100 x MTER x 100 x Tel: info@smoothflopumps.com.au page 27

30 GALVANIZED MALLEABLE FITTINGS GALVANIZED MALLEABLE EQUAL CROSS (ITEM NO. 180) SMOOTHFLO FIRE UL APPROVAL CODE SIZE (mm) H APP. WEIGHT (kg/pc) MCRQ06 6 (1/8 ) MCRQ08 8 (1/4 ) MCRQ10 10 (3/8 ) MCRQ15 15 (1/2 ) MCRQ20 20 (3/4 ) MCRQ25 25 (1 ) MCRQ32 32 (1-1/4 ) MCRQ40 40 (1-1/2 ) MCRQ50 50 (2 ) MCRQ65 65 (2-1/2 ) MCRQ80 80 (3 ) MCRQ (4 ) GALVANIZED MALLEABLE SOCKET (ITEM NO. 220) UL APPROVAL CODE SIZE (mm) H APP. WEIGHT (kg/pc) MSOQ06 6 (1/8 ) MSOQ08 8 (1/4 ) MSOQ10 10 (3/8 ) MSOQ15 15 (1/2 ) MSOQ20 20 (3/4 ) MSOQ25 25 (1 ) MSOQ32 32 (1-1/4 ) MSOQ40 40 (1-1/2 ) MSOQ50 50 (2 ) MSOQ65 65 (2-1/2 ) MSOQ80 80 (3 ) MSOQ (4 ) GALVANIZED MALLEABLE UNION WITH GASKET SEALING (ITEM NO. 330D) UL APPROVAL CODE SIZE (mm) L APP. WEIGHT (kg/pc) MUNQ06 6 (1/8 ) MUNQ08 8 (1/4 ) MUNQ10 10 (3/8 ) MUNQ15 15 (1/2 ) MUNQ20 20 (3/4 ) MUNQ25 25 (1 ) MUNQ32 32 (1-1/4 ) MUNQ40 40 (1-1/2 ) MUNQ50 50 (2 ) MUNQ65 65 (2-1/2 ) MUNQ80 80 (3 ) MUNQ (4 ) Tel: info@smoothflopumps.com.au page 28

31 GALVANIZED MALLEABLE FITTINGS GALVANIZED MALLEABLE REDUCING SPCKET (ITEM NO. 240) SMOOTHFLO FIRE UL APPROVAL CODE SIZE (mm) H APP. WEIGHT (kg/pc) MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x MSOR x Tel: info@smoothflopumps.com.au page 29

32 GALVANIZED MALLEABLE FITTINGS GALVANIZED MALLEABLE SQUARE HEAD PLUG (ITEM NO. 291) SMOOTHFLO FIRE UL APPROVAL CODE SIZE (mm) D H APP. W (kg/pc) MPLU08 8 (1/4 ) MPLU10 10 (3/8 ) MPLU15 15 (1/2 ) MPLU20 20 (3/4 ) MPLU25 25 (1 ) MPLU32 32 (1-1/4 ) MPLU40 40 (1-1/2 ) MPLU50 50 (2 ) MPLU65 65 (2-1/2 ) MPLU80 80 (3 ) MPLU (4 ) GALVANIZED MALLEABLE HEXAGONAL NUT (ITEM NO. 310) UL APPROVAL CODE SIZE (mm) A B APP. W (kg/pc) MNUT08 8 (1/4 ) MNUT10 10 (3/8 ) MNUT15 15 (1/2 ) MNUT20 20 (3/4 ) MNUT25 25 (1 ) MNUT32 32 (1-1/4 ) MNUT40 40 (1-1/2 ) MNUT50 50 (2 ) MNUT65 65 (2-1/2 ) MNUT80 80 (3 ) MNUT (4 ) GALVANIZED MALLEABLE CAP (ITEM NO. 301) UL APPROVAL CODE SIZE (mm) H APP. W (kg/pc) MCAP06 6 (1/8 ) MCAP08 8 (1/4 ) MCAP10 10 (3/8 ) MCAP15 15 (1/2 ) MCAP20 20 (3/4 ) MCAP25 25 (1 ) MCAP32 32 (1-1/4 ) MCAP40 40 (1-1/2 ) MCAP50 50 (2 ) MCAP65 65 (2-1/2 ) MCAP80 80 (3 ) MCAP (4 ) MCAP (6 ) Tel: info@smoothflopumps.com.au page 30

33 GALVANIZED MALLEABLE FITTINGS GALVANIZED MALLEABLE HEXAGON BUSH (ITEM NO. 241) SMOOTHFLO FIRE UL APPROVAL CODE SIZE (mm) D H APP. W (kg/pc) MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x MBUS x Tel: info@smoothflopumps.com.au page 31

34 GALVANIZED MALLEABLE FITTINGS SMOOTHFLO FIRE GALVANIZED MALLEABLE FEMALE-FEMALE BEND 90 DEGREE (ITEM NO. 2) UL APPROVAL CODE SIZE (mm) A APP. W (kg/pc) MBEN06 6 (1/8 ) MBEN08 8 (1/4 ) MBEN10 10 (3/8 ) MBEN15 15 (1/2 ) MBEN20 20 (3/4 ) MBEN25 25 (1 ) MBEN32 32 (1-1/4 ) MBEN40 40 (1-1/2 ) MBEN50 50 (2 ) MBEN65 65 (2-1/2 ) MBEN80 80 (3 ) MBEN (4 ) GALVANIZED MALLEABLE MALE-FEMALE BEND 90 DEGREE (ITEM NO. 1) UL APPROVAL CODE SIZE (mm) A B APP. W (kg/pc) MBMF06 6 (1/8 ) MBMF08 8 (1/4 ) MBMF10 10 (3/8 ) MBMF15 15 (1/2 ) MBMF20 20 (3/4 ) MBMF25 25 (1 ) MBMF32 32 (1-1/4 ) MBMF40 40 (1-1/2 ) MBMF50 50 (2 ) MBMF65 65 (2-1/2 ) MBMF80 80 (3 ) MBMF (4 ) Tel: info@smoothflopumps.com.au page 32

35 GALVANIZED MALLEABLE FITTINGS SMOOTHFLO FIRE GALVANIZED MALLEABLE FLANGE - DRILLED TO TABLE E/D (ITEM NO. 321P) CODE SIZE (mm) A D1 PCD APP. W (kg/pc) MFLD06 6 (1/8 ) MFLD08 8 (1/4 ) MFLD10 10 (3/8 ) MFLD15 15 (1/2 ) MFLD20 20 (3/4 ) MFLD25 25 (1 ) MFLD32 32 (1-1/4 ) MFLD40 40 (1-1/2 ) MFLD50 50 (2 ) MFLD65 65 (2-1/2 ) MFLD80 80 (3 ) MFLD (4 ) MFLD (6 ) UL APPROVAL GALVANIZED MALLEABLE FLANGE - UNDRILLED TO TABLE D/E (ITEM NO. 321PW) CODE SIZE (mm) A D1 APP. W (kg/pc) MFLU06 6 (1/8 ) MFLU08 8 (1/4 ) MFLU10 10 (3/8 ) MFLU15 15 (1/2 ) MFLU20 20 (3/4 ) MFLU25 25 (1 ) MFLU32 32 (1-1/4 ) MFLU40 40 (1-1/2 ) MFLU50 50 (2 ) MFLU65 65 (2-1/2 ) MFLU80 80 (3 ) MFLU (4 ) MFLU (6 ) UL APPROVAL Tel: info@smoothflopumps.com.au page 33

36 SPRINKLER HEADS SMOOTHFLOW AUSTRALIA SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed RESPONSE Quick response Standard response COLOURS Natural brass Chromed Power coated white TEMPERATURE 68 o C 79 o C 93 o C BULBS & SPRING SEALS: Manufactured by German company - The JOB GmBH: Their web is UL LISTED TWO PIECE ESCUTCHEONS Two piece slip-on style Recessed Escutcheons Depth of Outer Cup: 27 mm Outside Diameter of Outer Cup: 76 mm Depth of Center Adapter Ring: 9 mm +/- 0.8 mm Adjustment Range: Flush to 18 mm recessed Tel: info@smoothflow.com.au Page 34

37 Automatic Sprinklers TECHNICAL DATA TD01516 PIN: NX003-NX rd Edition UPRIGHT SPRINKLERS AND PENDENT SPRINKLERS MODEL: NX003 / NX004 / NX005 / NX006 STANDARD SPRAY, STANDARD / QUICK RESPONSE, 5 / 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD GENERAL DESCRIPTION The NX003/NX004 Standard/Quick Response Upright and NX005/NX006 Standard/Quick Response Pendent Sprinklers (Ref. Figure A) are automatic sprinklers of the frangible bulb type. They are standard/quick response standard orifice spray sprinkler intended for use in fire sprinkler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 requirements). The Upright, Pendent Sprinklers all produce a hemispherical water distribution pattern below the deflector. 1-13/32" ( 35.5mm ) WRENCH FLAT SPRINKLER OPERATION During a fire conditions, the thermal-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the button and spring seal assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. COVERAGE For coverage area and sprinkler placement, refer to NFPA13 standards. ESCUTCHEON RING SEATING SURFACE 1/2" PIPE THREAD 1-19/32" ( 40.9mm ) 2-1/4" ( 56.9mm ) CENTERLINE OF WATERWAY /16" ( 42.5mm ) 2-5/16" ( 58.2mm ) 8 UPRIGHT 1/2" PIPE THREAD 27/32" ( 21.8mm ) CROSS SECTION 1-1/4" ( 31.5mm ) PENDENT 2-15/16" (75mm ) TYPICAL INSTALLATION 1.SSU DEFLECTOR 2.SET SCREW 3.GLASS BULB 4.FRAME 5.BUTTON 6.SPRING SEAL 7.SSP DEFLECTOR 8.STANDARD ESCUTCHON FIGURE A : MODEL NX003/NX004 UPRIGHT & MODEL NX005/NX006 PENDENT SPRINKLERS TECHNICAL SPECIFICATIONS Model & Sprinkler I.D. No. NX003 NX004 NX005 NX006 Style Upright Pendent Bulb Nominal Dia. & Response Ø5mm, Standard Ø3mm, Quick Ø5mm, Standard Ø3mm, Quick Response Response Response Response Thread Size [Optional] NPT1/2 or R1 2 Nominal Orifice Size 1/2 Inch Nominal K-Factor 5.6 (U.S.) 80 (metric) Max. Working Pressure 175 psig 1.2 MPa (12 bar) Factory Hydrostatic Test 500psig (3.4 MPa) Min. Operating Pressure 7 psig MPa (0.48 bar) Sprinkler Finish [Optional] Natural Brass Chrome Plated White Color Coated SMOOTHFLOW AUSTRALIA PTY LTD TEL: TECHNICAL DATA SHEET TD HEALD ROAD, INGLEBURN, NSW 2565 info@smoothflow.com.au

38 Automatic Sprinklers TECHNICAL DATA TD01516 PIN: NX003-NX rd Edition Escutcheon Finish Listings and Approvals AVAILABLE TEMPERATURE RATING Chrome Plated or Color Coated In Any Color UL(United States) ULC(Canada) Temp. Classification Ordinary Ordinary Intermediate Intermediate Nominal Temp. Rating 135 F 57 C 155 F 68 C 175 F 79 C 200 F 93 C Max. Ambient Temp. Allowed F 46 C 135 F 57 C 155 F 68 C 180 F 82 C Max. Recommended Ambient Temp F 38 C 100 F 38 C 150 F 65 C 150 F 65 C Glass Bulb Color 7 Orange Red Yellow Green Footnotes: 1 Sprinkler I.D. Nos. and nominal U.S. K-factors provided in accordance with the 2002 edition of NFPA The pipe thread connections accord with ISO7/1. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 UL and ULC Listed for both Light-Hazard and Ordinary-Hazard occupancies. 5 Based on National Fire Prevention and Control Administration Contract No Based on NFPA 13. Other limits may apply depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 7 The temperature rating is stamped on the deflector or adjacent to orifice seat on frame. SPRINKLER MATERIALS Bronze Forging UNS-C87400 Frame or Casting DZR Deflector Brass UNS Glass with Glycerin Solution, JOB G5 or Day-Impex-937 for Glass Bulb NX003/ NX005 JOB F3 0r Day-Impex-941 for NX004/ NX006 Set Screw Brass UNS Button Brass UNS Spring Stainless Steel Seal Teflon Tape Standard Escutcheon Cold Rolled Steel (Type E-1) ACCESSORIES Standard Escutcheon Type E-1 Installation Wrench Type T-1 DISCHARGE COEFFICIENT Model NX003/NX004 Upright and Model NX005/NX006 Pendent Sprinklers are rated for use at a maximum service pressure of 175 psig (12 bar). The nominal discharge curve plotted in Figure B represents the flow Q in GPM (LPM) as determined by the following formula: Q=K(P) 0.5 Where: DISCHARGE IN U.S. GALLONS PER MINUTE (GPM) PRESSURE IN POUNDS PER SQUARE INCH (PSIG) PARTIAL CURVE ONLY MAX. PRESSURE 175 PSIG PARTIAL CURVE ONLY 20 MAX. PRESSURE 1.2 MPA 0.2 NOMINAL K=5.6 NOMINAL K= PRESSURE IN MPA FIGURE B : NOMINAL DISCHARGE CURVE Q Flow, GPM (LPM) K Discharge Coefficient, K=5.6 (80) P Discharge Pressure, psig (bar) Listing standards permit the actual value of K to vary from 5.3 to 5.8 (76,4 to 83,6); however, for hydraulic calculations, a K-factor of 5.6 (80,7) is to be applied. DISCHARGE IN LITERS PER MINUTE (LPM) SMOOTHFLOW AUSTRALIA PTY LTD TEL: TECHNICAL DATA SHEET TD HEALD ROAD, INGLEVURN, NSW 2565, info@smoothflow.com.au

39

40 Automatic Sprinklers TECHNICAL DATA TD01516 PIN: NX003-NX rd Edition WARNING The Model NX003/NX004 Upright Sprinklers and Model NX005/NX006 Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the integrity of these devices. impairment of the sprinkler. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or manufacturer should be contacted relative to any questions. INSTALLATION NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontal, a small air bubble should be present. The Model NX003/NX004 Upright Sprinklers and Model NX005/NX006 Pendent Sprinklers must be installed in accordance with the following instructions. 1. Prior to installing the sprinklers, if applicable, verify that the face of the sprinkler fitting is within the proper range of distance, which can be accommodated by the type of escutcheon being used. 2. With pipe thread sealant applied to the pipe threads and after installing standard escutcheon, over the sprinkler threads, hand tighten the sprinkler into the sprinkler fitting. 3. Refer to Figure D and select the appropriate Sprinkler Wrench for tightening the sprinkler into the sprinkler fitting. NOTES A leak tight 1/2 pipe thread sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9.5 to 19.0 Nm). A maximum of 21 ft.lbs. (28.5 Nm) of torque is to be used to install the sprinkler. Higher levels of torque may distort the sprinkler inlet with consequent leakage or TYPICAL INSTALLATION FIGURE C : MODEL NX005/NX006 PENDENT SPRINKLER INSTALLED WITH A STANDARD ESCUTCHEON SPRINKLER WRENCH T-1 FIGURE D : SPRINKLER WRENCH SELECTION & USE Push on the Sprinkler Wrench, while it is being turned, to ensure that the Wrench recess stays fully engaged with the sprinkler wrench flats. Carefully remove the Sprinkler Wrench by disengaging it from the sprinkler wrench flats, and then lowering it down over the sprinkler deflector. CARE AND MAINTENANCE Automatic sprinklers must never be shipped or stored where their temperatures will exceed SMOOTHFLOW AUSTRALIA PTY LTD TEL: TECHNICAL DATA SHEET TD HEALD ROAD, INGLEBURN, NSW 2565 info@smoothflow.com.au

41 Automatic Sprinklers TECHNICAL DATA TD01516 PIN: NX003-NX rd Edition 100 F/38 C and they must never be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers both before and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (ref. Installation Section Note). NOTES Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Before closing a fire protection system control valve for maintenance work on the fire protection system, which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. It is recommended that automatic sprinkler systems be inspected quarterly by a qualified Inspection Service. ORDERING PROCEDURE A Product Symbol Number (PSN) shall be specified when ordering sprinklers. And it is suggested that a color chip be provided when ordering special color coated Escutcheons. Otherwise, responsibility for duplication cannot be accepted. Contact your local distributor for availability. Sprinkler Assemblies: Specify: 1/2" orifice, (specify temperature rating), Model NX003/NX004 Upright Sprinklers with (specify type of finish), PSN (specify as follows). NX003/NX004 Standard/Quick Response Upright Sprinklers : PSN 012 X 1 13 X 2 X 3 X 1 Response Frame 1 Standard Response UNS-C Quick Response,UNS-C Standard Response DZR 4 Quick Response DZR X 2 Class Bulb and Nominal Temperature Rating 1 Job,135 F 57 C 2 Job,155 F 68 C 3 Job,175 F 79 C 4 Job,200 F 93 C 5 Day-Impex,135 F 57 C 6 Day-Impex,155 F 68 C 7 Day-Impex,175 F 79 C 8 Day-Impex,200 F 93 C X 3 Thread Size and Sprinkler Finish 1 NPT1/2 Natural Brass 2 NPT1/2 Chrome Plated 3 R1 2 per ISO 7/1 Natural Brass 4 R1 2 per ISO 7/1 Chrome Plated 5 NPT1/2 White Color Coated 6 R1 2 White Color Coated NX005/NX006 Standard/Quick Response Pendent Sprinklers : PSN 012 X 1 23 X 2 X 3 X 1 Response and Frame 1 Standard Response UNS-C Quick Response,UNS-C Standard Response DZR 4 Quick Response DZR X 2 Class Bulb and Nominal Temperature Rating 1 Job,135 F 57 C 2 Job,155 F 68 C 3 Job, 175 F 79 C 4 Job, 200 F 93 C 5 Day-Impex, 135 F 57 C 6 Day-Impex, 155 F 68 C 7 Day-Impex, 75 F 79 C 8 Day-Impex, 200 F 93 C X 3 Thread Size and Sprinkler Finish 1 NPT1/2 Natural Brass 2 NPT1/2 Chrome Plated 3 R1 2 per ISO 7/1 Natural Brass 4 R1 2 per ISO 7/1 Chrome Plated 5 NPT1/2 White Color Coated 6 R1 2 White Color Coated Accessories: SMOOTHFLOW AUSTRALIA PTY LTD TEL: TECHNICAL DATA SHEET TD HEALD ROAD, INGLEBURN, NSW 2565 info@smoothflow.com.au

42 Automatic Sprinklers TECHNICAL DATA TD01516 PIN: NX003-NX rd Edition Order the following accessories, as applicable: Type E-1 1/2" Standard Escutcheon with chromate finishes: PSN Type E-1 1/2" Standard Escutcheon with white painted finish: PSN Type T-1 Wrench: PSN0109 WEIGHT The nominal weights are as follows. 1/2" Orifice Model NX003/ NX004 Upright 2.8 ozs. (80 g) 1/2" Orifice Model NX005/ NX006 Pendent 2.8 ozs. (80 g) E-1 Standard Escutcheon 0.6 ozs. (18 g) T-1 Sprinkler Wrench 18 ozs. (510 g) CONVERSION TABLE Name of Unit Unit Conversion Symbol Factor Millimeter mm 1 in.=25.4 mm Square meter m 2 1 ft 2 = m 2 Liter L 1 gal=3.785 L Cubic decimeter dm 3 1 gal=3.785 dm 3 Cubic meter m 3 1 ft 3 = m 3 Kilogram kg 1 lb=16 ozs.= kg Kilograms per cubic meter Kg/m 3 1 lb/ft 3 = kg/m 3 Pascal Pa 1 psi=6895 Pa Bar bar 1 psi= bar Newton meter N m 1 ft lbs=1.355 N m This! WARNING product must be installed by an experienced, trained installer, in accordance with the instructions provided with each valve. These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage. We reserve the right to change product specifications, designs and standard equipment without notice and without incurring obligations. If you have any questions about the safe installation and use of this device, contact Smoothflow Australia. SMOOTHFLOW AUSTRALIA PTY LTD TEL: TECHNICAL DATA SHEET TD HEALD ROAD, INGLEBURN, NSW 2565 info@smoothflow.com.au

43 Automatic Sprinklers TECHNICAL DATA TD01518 PIN: NX017/NX rd Edition HORIZONTAL SIDEWALL SPRINKLERS MODEL: NX017 / NX018 STANDARD SPRAY, STANDARD / QUICK RESPONSE, 5 / 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD GENERAL DESCRIPTION Horizontal sidewall sprinklers are generally used in lieu of pendent and upright sprinklers because of building construction or installation economy considerations. They are designed for installation along a wall or the side of a beam and just beneath a smooth ceiling. Installed with their centerline of waterway horizontal, these sprinklers produce a quarter-spherical water discharge pattern that is predominately directed downward and outward from the deflector; however, a portion of the spray is also directed towards the back wall. Model NX017 / NX018, Standard / Quick Response Horizontal Sidewall Sprinklers (Ref. Figure A), are automatic sprinklers of the frangible bulb type, and standard spray, 1/2 orifice, 5 / 3 mm bulb. They are standard / quick response - standard orifice sidewall sprinklers intended for use in fire sprinkler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 requirements). SPRINKLER OPERATION During a fire conditions, the thermal-sensitive liquid in the glass bulb expands, causing the /16"(14mm) CENTERLINE OF WATERWAY 2-1/8" (54mm) 2-3/4" (70mm) 1/2" PIPE THREAD 1.DEFLECTOR 2.SET SCREW 3.GLASS BULB 4.SPRING SEAL 7/8"(22mm) WRENCH FLAT 5.BUTTON 6.FRAME FIGURE A : MODEL NX017/NX018 HORIZONTAL SIDEWALL SPRINKLERS bulb to shatter, releasing the button and spring seal assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. COVERAGE For coverage area and sprinkler placement, refer to NFPA13 standards. TECHNICAL SPECIFICATIONS Model & Sprinkler I.D. No. NX017 NX018 Style Horizontal Sidewall Response & Bulb Nominal Dia. Standard Response, Ø5 mm Quick Response, Ø3 mm Thread Size [Optional] NPT1/2 or R1 2 Nominal Orifice Size 1/2 Inch Nominal K-Factor (U.S.) 80 (metric) Max. Working Pressure 175 psig 1.2 MPa (12 bar) Factory Hydrostatic Test 500psig (3.4 MPa) Min. Operating Pressure 7 psig MPa (0.48 bar) Sprinkler Finish [Optional] Natural Brass or Chrome Plated White Color Coated Listings and Approvals UL(United States) ULC(Canada) SMOOTHFLOW AUSTRALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn NSW 2565 info@smoothflow.com.au

44 Automatic Sprinklers TECHNICAL DATA TD01518 PIN: NX017/NX rd Edition AVAILABLE TEMPERATURE RATING Temp. Classification Ordinary Ordinary Intermediate Intermediate Nominal Temp. Rating 135 F 57 C 155 F 68 C 175 F 79 C 200 F 93 C Max. Ambient Temp. Allowed F 46 C 135 F 57 C 155 F 68 C 180 F 82 C Max. Recommended Ambient Temp F 38 C 100 F 38 C 150 F 65 C 150 F 65 C Glass Bulb Color 7 Orange Red Yellow Green Footnotes: 1 Sprinkler I.D. Nos. and nominal U.S. K-factors provided in accordance with the 2002 edition of NFPA The pipe threads connections accord with ISO7/1. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 UL and ULC Listed for both Light-Hazard and Ordinary-Hazard occupancies. 5 Based on National Fire Prevention and Control Administration Contract No Based on NFPA 13. Other limits may apply depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 7 The temperature rating is stamped on the deflector or adjacent to orifice seat on frame. Note: Locate with deflectors 4 to 6 (100mm to 150mm) from walls. Align horizontal sidewall sprinklers with top of deflectors parallel to the ceiling or roof. SPRINKLER MATERIALS Frame Deflector Glass Bulb Set Screw Button Spring Seal Standard Escutcheon (Type E-1) ACCESSORIES Bronze Casting DZR Brass UNS Glass with Glycerin Solution, JOB G5 or Day-Impex-937 for NX017 JOB F3 0r Day-Impex-941 for NX018 Brass UNS Brass UNS Stainless Steel Teflon Tape Cold Rolled Steel Standard Escutcheon Type E-1 Installation Wrench Type T-1 DISCHARGE COEFFICIENT Model NX017/NX018 Horizontal Sidewall Sprinklers are rated for use at a maximum service pressure of 175 psig (12 bar). The nominal discharge curve plotted in Figure B represents the flow Q in GPM (LPM) as determined by the following formula: Q=K(P) 0.5 Where: Q Flow, GPM (LPM) K Discharge Coefficient, K=5.6 (80) P Discharge Pressure, psig (bar) DISCHARGE IN U.S. GALLONS PER MINUTE (GPM) PRESSURE IN POUNDS PER SQUARE INCH (PSIG) PARTIAL CURVE ONLY MAX. PRESSURE 175 PSIG PARTIAL CURVE ONLY 20 MAX. PRESSURE 1.2 MPA 0.2 NOMINAL K=5.6 NOMINAL K= PRESSURE IN MPA FIGURE B : NOMINAL DISCHARGE CURVE Listing standards permit the actual value of K to vary from 5.3 to 5.8 (76.4 to 83.6); however, for hydraulic calculations, a K-factor of 5.6 (80.7) is to be applied. DISCHARGE IN LITERS PER MINUTE (LPM) SMOOTHFLOW AUSTRALIA PTY LTD Tel: Techanical Data Sheet TD Heald Road, Ingleburn, NSW 2565 info@smoothflow.com.au

45 WARNING Automatic Sprinklers TECHNICAL DATA SPRINKLER FITTING TD01518 PIN: NX017/NX rd Edition SPIRIT LEVEL The Model NX017/NX018 Horizontal Sidewall Sprinklers described herein must be installed and maintained in compliance with this document, as well as applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or manufacturer should be contacted relative to any questions. INSTALLATION NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontal, a small air bubble should be present. The diameter of the air bubble is approximately 1/16" (1.6mm) for the 135 F/57 C to 3/32" (2.4mm) for the 286 F/141 C rating. (At higher ambient temperatures, the bubble may be barely perceptible for the lower temperature ratings.) The Model NX017/NX018 Horizontal Sidewall Sprinklers must be installed in accordance with the following instructions. 1. Prior to installing the sprinklers, if applicable, verify that the face of the sprinkler fitting is within the proper range of distance, which can be accommodated by the type of escutcheon being used. 2. The Model NX017/NX018 Horizontal Sidewall Sprinklers must be installed with the centerline of waterway horizontal and perpendicular to a back wall surface. It is recommended that a lightweight spirit level (less than 1 pound), be used to level the sprinkler fitting, as shown in Figure D and that a square be used to check perpendicularity of the waterway centerline to the mounting surface. CENTERLINE OF WATERWAY 6" (150mm) OR LONGER NIPPLE DEFLECTOR FIGURE C: LEVELING OF SPRINKLER FITTING AND DEFLECTOR 3. With pipe thread sealant applied to the pipe threads and after installing standard escutcheon, over the sprinkler threads, hand tighten the sprinkler into the sprinkler fitting. 4. Refer to Figure E and select the appropriate Sprinkler Wrench for tightening the sprinkler into the sprinkler fitting. The word TOP on the Deflector must face upwards towards the ceiling. The Type T-1 Sprinkler Wrench must be used for installing Model NX017/NX018 sprinklers. When using T-1 type wrench, the wrench is to be applied to the sprinkler wrench flats only (Ref. Figure A). NOTES A leak tight 1/2 pipe thread sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9.5 to 19.0 Nm). The maximum installing torque shall not excess 21 ft.lbs. (28.5 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. SMOOTHFLOW AUSTRALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn, NSW 2565 info@smoothflow.com.au

46

47 Automatic Sprinklers TECHNICAL DATA TD01518 PIN: NX017/NX rd Edition SPRINKLER WRENCH T-1 valve for maintenance work on the fire protection system, which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. It is recommended that automatic sprinkler systems be inspected quarterly by a qualified Inspection Service. ORDERING PROCEDURE FIGURE D : SPRINKLER WRENCH SELECTION & USE Push on the Sprinkler Wrench, while it is being turned, to ensure that the Wrench recess stays fully engaged with the sprinkler wrench flats. Carefully remove the Sprinkler Wrench by disengaging it from the sprinkler wrench flats, and then lowering it down over the sprinkler deflector. It is recommended that a spirit level be used to level the Deflector, as shown in Figure D. CARE AND MAINTENANCE Automatic sprinklers must never be shipped or stored where their temperatures will exceed 100 F/38 C and they must never be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers both before and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (ref. Installation Section Note). NOTES Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Before closing a fire protection system control A Product Symbol Number (PSN) shall be specified when ordering sprinklers. And it is suggested that a color chip be provided when ordering special color coated Escutcheons. Otherwise, responsibility for duplication cannot be accepted. Contact your local distributor for availability. Sprinkler Assemblies: Specify: 1/2" orifice, (specify temperature rating), Model NX017/NX018 Standard/Quick Response Horizontal Sidewall Sprinkler with (specify type of finish), PSN (specify as follows). NX017/NX018 Standard/Quick Response Horizontal Sprinklers : PSN 012 X 1 33 X 2 X 3 X 1 Response 3 Standard Response 4 Quick Response X 2 Class Bulb and Nominal Temperature Rating 1 Job,135 F 57 C 2 Job,155 F 68 C 3 Job,175 F 79 C 4 Job,200 F 93 C 5 Day-Impex,135 F 57 C 6 Day-Impex,155 F 68 C 7 Day-Impex,175 F 79 C 8 Day-Impex,200 F 93 C X 3 Thread Size and Sprinkler Finish 1 NPT1/2 Natural Brass 2 NPT1/2 Chrome Plated 3 R1 2 per ISO 7/1 Natural Brass 4 R1 2 per ISO 7/1 Chrome Plated 5 NPT1/2 White Color Coated 6 R1 2 White Color Coated SMOOTHFLOW AUSTRALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn, NSW 2565 info@smoothflow.com.au

48 Automatic Sprinklers TECHNICAL DATA TD01518 PIN: NX017/NX rd Edition Accessories: Order the following accessories, as applicable: Type E-1 1/2" Standard Escutcheon with chromate finishes: PSN Type E-1 1/2" Standard Escutcheon with white painted finish: PSN Type T-1 Wrench: PSN0109 WEIGHT The nominal weights are as follows. 1/2" Orifice Model NX017/ NX018 Horizontal Sidewall 2.8 ozs. (80 g) E-1 Standard Escutcheon 0.6 ozs. (18 g) T-1 Sprinkler Wrench 18 ozs. (510 g) CONVERSION TABLE Name of Unit Unit Conversion Symbol Factor Millimeter mm 1 in.=25.4 mm Square meter m 2 1 ft 2 = m 2 Liter L 1 gal=3.785 L Cubic decimeter dm 3 1 gal=3.785 dm 3 Cubic meter m 3 1 ft 3 = m 3 Kilogram kg 1 lb=16 ozs.= kg Kilograms per cubic meter Kg/m 3 1 lb/ft 3 = kg/m 3 Pascal Pa 1 psi=6895 Pa Bar bar 1 psi= bar Newton meter N m 1 ft lbs=1.355 N m This! WARNING product must be installed by an experienced, trained installer, in accordance with the instructions provided with each valve. These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage. We reserve the right to change product specifications, designs and standard equipment without notice and without incurring obligations. If you have any questions about the safe installation and use of this device, contact Smoothflow Australia SMOOTHFLOW AUSTRALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn, NSW 2565 info@smoothflow.com.au

49 Alarm Check Valve TECHNICAL DATA TD01111 PIN: NX nd Edition Alarm Check Valve MODEL: NX psi (12 bar), 4" & 6" (DN100 & DN150), VERTICAL INSTALLATION GENERAL DESCRIPTION Model NX009 Alarm Check Valve is a wet pipe sprinkler system water supply check valve that makes possible the installation of sprinkler systems in buildings not subject to freezing temperatures. It is designed so that water pressure in the piping system will hold back water pressure at the valve until a significant flow of water occurs. The Alarm Check Valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping. The valve is trimmed with a water bypass line. The bypass line allows pressure surges to enter TECHNICAL SPECIFICATIONS the system and to be trapped above the alarm check valve s clapper without the clapper lifting and causing false alarms. When a significant sustained flow of water occurs, such as from an open sprinkler, the alarm valve s clapper lifts and allows water to enter the system. Simultaneously, water enters an intermediate chamber, which allows the water to activate an alarm either through an optional water motor alarm and/or through a water pressure alarm. These alarms continue to sound until the flow of water is stopped. The NX009 Alarm Check Valve should be installed vertically on wet-pipe sprinkler systems with constant pressure or variable pressure water supplies. The valve is made suitable for use on variable pressure water supplies by adding the optional retard chamber to the standard trim. The valve is available with a flanged inlet and flanged outlet or with a grooved inlet and grooved outlet. Size 4" (DN100) 6" (DN150) Inlet Connection Style Flange Groove Flange Groove Outlet Connection Style Flange Groove Flange Groove Shipping Weight 55 lbs 25 kg 51 lbs 23 kg 75 lbs 34 kg 66 lbs 30 kg Max. Working Pressure 175 psig 1.2 MPa (12 bar) Factory Hydro Test 350 psig 2.4 MPa (24 bar) Standard Finish Red Painted Flange & Groove Specification Flange: Class 150 ANSI B16.1 & Groove: C606 ANSI AWWA Required Accessories Standard Trim Optional Accessories Retard Chamber, Water Motor Alarm, Alarm Pressure Switch Installation Manner Vertically Listings and Approvals UL (United States) UL LISTED FRICTION LOSS For use in hydraulic calculations, the pressure loss through the Alarm Check Valves may be expressed in equivalent length of pipe, based on Hazen & Williams formula with C=120 based on ANSI standard wall straight pipe. 4 Valve = 28 feet (8.5 m) 6 Valve = 32 feet (9.8 m) SMOOTHFLOW AUSTRALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn, NSW 2565, info@smoothflow.com.au

50 Alarm Check Valve TECHNICAL DATA TD01111 PIN: NX nd Edition PRESSURE DROP IN POUNDS PER SQUARE INCH (PSI) FLOW RATE IN LITRES PER MINUTE (LPM) (1 GPM = LPM) " (DN100) 6" (DN150) FLOW RATE IN GALLONS PER MINUTE (GPM) Figure 1: Nominal Hydraulic Friction Loss of Model NX009 Alarm Check Valve TRI M PACKAGES Model NX009 Alarm Check Valve is listed and/or approved with specific trim for use up to 175 psig 1.2 MPa (12 bar). No substitutions or omissions, in part or in full, are allowed. Additional accessories to the standard trim packages are required for a complete system meeting the requirements of the applicable rules and codes. See appropriate technical data for additional information. STANDARD TRIM PACKAGES include: 1. All necessary nipples and fittings 2. All standard trim accessories 3. All necessary gauges OPTIONAL ACCESSORIES ORDER SEPARATELY Retard Chamber UL LISTED The Retard Chamber is required when the NX009 Alarm Check Valve is installed on systems with a variable pressure water supply in order to reduce the possibility of false alarms. Refer to the NX015 Retard Chamber technical data TD Water Motor Alarm The NX009 Alarm Check Valve is designed to activate a mechanical alarm during a sustained flow of water (such as the flow required by an open sprinkler) causes the alarm check valve s clapper to lift from its seat. Refer to the NX010 Water Motor Alarm technical data TD Alarm Pressure Switch The NX009 Alarm Check Valve trim allows installation of pressure switches to operate local electric alarms and/or remote electric alarms during a sustained flow of water (such as the flow requires by an open sprinkler). Refer to Alarm Pressure Switch technical data. PRESSURE DROP IN BAR (BAR) (1 PSI = BAR) VALVE DESCRIPTION DIMENSIONS inch (mm) Valve Size H H 1 H 2 H 3 H 4 H 5 H 6 4" Flange (270) (2.0) (23.9) (40) (83) (193) (230) 4" Groove 11.0 (280) (15.9) (9.5) 2.0 (50) (93) 8.0 (203) (230) 6" Flange (346) (2.0) (23.9) (53) (111) (270) (244) 6" Groove (346) (15.9) (9.5) (53) (111) (270) (244) SMOOTHFLOW AUSTRALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn, NSW2565 info@smoothflow.com.au

51 Alarm Check Valve TECHNICAL DATA TD01111 PIN: NX nd Edition OD D1 H1 GROOVE STYLE H2 Ref H7 D H8 GROOVE STYLE DIMENSIONS H3 H4 H H5 Ref H7 H4 2" DRAIN 3/4" ALARM OUTLET H2 Position of inst UL LISTED TUNA Figure 2: Model NX009 Alarm Check Valve, Partial Sections D2 D1 OD 3/4" 3/4" H1 H3 H6 inch (mm) Valve Size RefH 7 H 8 OD D 1 D 2 D 3 4" Flange (77) (103) Ø9.0 (228.6) Ø7.5 (190.5) Ø6.188 (157.2) 8XØ0.750 (19) 4" Groove (77) (113) Ø4.5 (114.3) Ø4.334 (110.1) 6" Flange 3.0 (76) (132) Ø11.0 (279.4) Ø9.5 (241.3) Ø8.5 (215.9) 8XØ0.875 (23) 6" Groove 3.0 (76) (132) Ø6.625 (168.3) Ø6.455 (164.0) PARTS H No. Part Name Qty. Part No. 4 (DN100) 6 (DN150) Material 1 Valve Body (Flange Style) Ductile Iron: Valve Body (Groove Style) Ductile Iron: Cover Plate Ductile Iron: Seat Ring Brass: C Cover Plate Bolt 6 M10X35 M12X40 Steel, Zinc Plated 5 Spring Washer Steel, Zinc Plated Remarks SMOOTHFLOW AUSTRALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn, NSW 2565 info@smoothflow.com.au

52 R LISTED Alarm Check Valve TECHNICAL DATA TD01111 PIN: NX nd Edition No. Part Name Qty. Part No. 4 (DN100) 6 (DN150) Material 6 Flat Washer Steel, Zinc Plated 7 Cover Plate Gasket Rubber SBR 8 Clapper Seal Retainer Stainless Steel: 304H 9 Clapper Seal EPDM 10 Clapper Screw 1 M12X15 M12X15 Stainless Steel: 304H 11 Clapper Brass: C Clapper Shaft Stainless Steel: Clapper Busing Brass: C37710 TRIM DESCRIPTION G S AL I PR N KL M A R ER UL LISTED K L A Position of installation:vertical TUNA B psi kpa psi kpa Remarks J H N M E C D F Figure 3: Model NX009 Alarm Check Valve, Vertical Trim DIMENSIONS inch (mm) SMOOTHFLOW AUSTRALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn, NSW 2565 info@smoothflow.com.au

53 Alarm Check Valve TECHNICAL DATA TD01111 PIN: NX nd Edition Valve Size A B C D E F G 4" Flange 18.2 (460) 9.8 (250) 9.8 (250) 13.6 (346) 27.6 (700) 19.0 (484) 22.4 (570) 4" Groove 18.2 (460) 9.8 (248) 9.8 (250) 13.6 (344) 27.6 (700) 19.0 (482) 22.8 (580) 6" Flange 19.4 (494) 11.2 (283) 11.2 (284) 15.0 (379) 28.9 (734) 20.4 (517) 23.5 (598) 6" Groove 19.4 (494) 11.2 (285) 11.2 (284) 15.0 (381) 28.9 (734) 20.4 (519) 23.5 (598) Valve Size H J K L M N 4" Flange 15.3 (388) 7.4 (188) 5.7 (145) 5.7 (145) 8.4 (213) 6.1 (154) 4" Groove 15.3 (388) 7.8 (198) 5.7 (145) 5.7 (145) 8.4 (213) 6.1 (154) 6" Flange 15.8 (402) 7.9 (200) 5.7 (145) 5.7 (145) 8.4 (213) 7.5 (191) 6" Groove 15.8 (402) 7.9 (200) 5.7 (145) 5.7 (145) 8.4 (213) 7.5 (191) BILL OF MATERIALS No. Description Qty. Remarks 1 Ball Valve 2 1 Main Drain Valve (Normally Closed), Type F1361FP 2 Nipple 2 X3¼ (80) 1 3 Nipple ¾ X2 (50) 8 4 Nipple ¾ X3¼ (80) 1 5 Union ¾ 2 6 Pressure Gauge Supply Pressure and System 2 0~300psi 2MPa Pressure, Type Y70B 7 Bushing ¾ X¼ 3 8 Galvanized Steel: G Nipple ¾ X2 (50) 2 Nipple ¾ X1¾ (45) 2 4 Groove Style 10 Check Valve ¾ , PN16, Bypass line Nipple ¾ X3¼ (80) 1 11 Nipple ¾ X3⅜ (85) 1 4 Groove Style Nipple ¾ X4 (100) 1 6 Groove Style Elbow ¾ 1 13 Tee ¾ X½ X¾ 2 14 Ball Valve ½ 1 Alarm Test Valve (Normally Closed), Type F1361FP 15 Nipple ½ X2¾ (70) Elbow ½ 2 17 Nipple ½ X1⅝ (40) 4 18 Union ½ 2 Nipple ½ X17⅝ (453) 1 4 Flange Style 19 Nipple ½ X17¾ (451) 1 4 Groove Style Nipple ½ X20½ (521) 1 6 Flange Style Nipple ½ X20½ (523) 1 6 Groove Style 20 Ball Valve ¾ 1 Alarm Shut-off Valve (Open Normally) 21 Strainer ¾ 1 Type F1191Y 22 Retard Chamber Optional, Ordered For Variable 1 Assembly Pressure Systems, NX Alarm Pressure Switch 1 Optional, Type PS75 24 Water Motor Alarm 1 Optional, Model NX010 INTRODUCTION The trim sets for the Model NX009 Alarm Valve are arranged for rapid, easy and compact attachment, and serves as connection points to Alarm and other devices. The Trim also serves as means for testing the operation of the alarm devices without causing the system to operate. Constant Pressure Closed Drain This trim set is used where water supply pressure does not vary, such as tank supplies. An automatic draining is provided to drain the mechanical sprinkler alarm line. This drain connection should be piped separately from the 2 (50mm) main drain. Variable Pressure With Open Retard Chamber Drain Retard Chamber is required. This trim set is used where water supply pressures vary, such as encountered with city water supplies. An open drip cup should be provided to drain the retard chamber and the mechanical sprinkler alarm line. This drain connection should be piped separately from the 2 main drain. UL LISTED SMOOTHFLOW AUSTRALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn, NSW 2565 info@smoothflow.com.au

54 Alarm Check Valve TECHNICAL DATA TD01111 PIN: NX nd Edition OPERATION WATER MOTOR DRAIN RETARD CHAMBER Figure 4: Model NX009 Alarm Check Valve, Variable Pressure Open Drain Trim RESTRICTED ORIFICE PRESSURE SWITCH MAIN DRAIN VALVE SYSTEM UL LISTED ALARM LINE ALARM SHUT-OFF VALVE MAIN WATER SUPPLY INTER- MEDIATE CHAMBER ALARM TEST VALVE Figure 5: Model NX009 Alarm Check Valve Operation SYSTEM PRESSURE GAUGE BYPASS LINE SUPPLY PRESSURE GAUGE BYPASS CHECK VALVE When the fire protection system is initially being pressurized, water will flow into the system until the water supply and system pressure become equalized. The Alarm Check Valve traps pressure above the Clapper and prevents the reverse flow of water. Once the pressures have stabilized, the Alarm Check Valve is in service and the intermediate chamber in the Seat Ring is sealed. Thus, with the Alarm Check Valve set for service, there is no flow through the alarm port to the alarm devices (i.e., Water Motor Alarm and/or Alarm Pressure Switch). When a sustained flow of water occurs, such as an operated sprinkler head or an open inspector s test connection, the Clapper lifts from its closed position. Water is then permitted to flow into the intermediate chamber in the Seat Ring. Then water SMOOTHFLOW AUSTRALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn, NSW 2565 info@smoothflow.com.au

55 Alarm Check Valve TECHNICAL DATA TD01111 PIN: NX nd Edition flows from the intermediate chamber to the alarm line and activates the system s alarms. These alarms continue to sound until the flow of water stop, such as closed Alarm Shut-off Valve. When a minor pressure surges occurs, slow as well as small transient increases in water supply pressure may continue to be built up in the system (via the Bypass Check Valve) without opening the Clapper. A transient surge in supply pressure that is sufficient to only momentarily open the Clapper will not cause a false alarm, and a portion of the increase in pressure will be trapped within the system, thus reducing the possibility of another opening. Any water in the alarm line is automatically drained, further reducing the possibility of a false alarm due to a successive transient surge in supply pressure. OPERATION WITH AN INSTALLED RETARD CHAMBER When the optional Retard Chamber is used, a surge of water, greater than what the bypass line can handle, will lift the clapper. Then water will enter the intermediate chamber through the holes in the Seat Ring, and it will fill the Retard Chamber. The water then drains from the DESIGN CRITERIA For the installation, consideration must be given to the disposal of the large quantities of water that may be associated with draining the system or performing a flow test. Vertically installed valves must have the flow going up. Horizontally installed valves must be positioned so that the drain connection points down. The sprinkler system designer must be aware that the configuration of the piping network and its tendency to trap pockets of air (such as in the case of a peaked-roof girded system) can affect the performance of the alarm system. Although a slight amount of trapped air is desirable to prevent significant pressure increases due to thermally induced expansion of the water, a large quantity of trapped air in a system may result in the possibility of an intermittent alarm. Retard Chamber through a Restricted Orifice. A sustained flow of water, as in an open sprinkler, will lift the clapper. The Retarding Chamber will fill faster than water can drain through the Restricted Orifice. And the water will fill the Retard Chamber completely; these events activate the Water Motor Alarm and/or Alarm Pressure Switch for the electric alarm. UL LISTED The possibility of an intermittent alarm condition is a consequence of the fact that the flow out of the system through the test valve or a single sprinkler is very small relative to the flow that can be passed through the valve. This difference increases with valve size. If the system were free of trapped air, flow in would equal flow out and the Clapper would always stabilize at some open position (as needed to accommodate the required flow). With trapped air in the system, however, the Clapper first opens wider since the system initially demands greater flow until the air pockets are compressed (back to nearly the supply pressure), and then it will tend to return closer to the Seat Ring. If the volume of the air pockets is excessive, flow into the system can be momentarily reduced to nearly zero (once the air pockets are compressed) and the Clapper may close, causing flow to the alarms to be shutoff. Once the Clapper has closed, sufficient water must flow out of the system before the Clapper will again open. A repetition of the above described condition is termed an intermittent alarm. Using a vent (which can also serve as an endof-line Inspector s Test Connection) piped from the top of a cross main or end of a branch line at the point most remote from the alarm valve, and filling the system slowly in accordance with the steps described in the Service Setting section, can prevent an excessive amount of air from being trapped. SMOOTHFLOW AUSTRALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn, NSW 2565 info@smoothflow.com.au

56 Alarm Check Valve TECHNICAL DATA TD01111 PIN: NX nd Edition INSTALLATION WARNING Model NX009 Alarm Check Valves described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the NFPA, in addition to the standards of any other authorities having jurisdictions. Failure to do so may impair the integrity of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or manufacturer should be contacted relative to any questions. STEP 1 Verify that the appropriate trim chart and technical data for the Alarm Check Valve and associated equipment are available. NOTES For proper operation, Model NX009 Alarm Check Valve must be trimmed in accordance with this data sheet for use on systems with water working pressure up to 175PSI 1.2 MPa (12 bar). Failure to follow this installation instruction may prevent the device from functioning properly as well as void listings/approvals, and the manufacturer s warranties. Model NX009 Alarm Check Valve must be installed in an area not subject to freezing temperatures or physical damage. Wet pipe sprinkler systems must be maintained at a minimum temperature of 40 F/4 C. When corrosive atmospheres and/or contaminated water supplies are present, it is the owner s responsibility to verify compatibility with the NX009 Alarm Check Valve, trim and associated equipment. UL LISTED STEP 2 Prior to the actual installing the valve; thoroughly flush the water supply piping to verify that no foreign matter is present. STEP 3 Unpack the valve and remove all plastic thread protectors from the opening of the valve. Inspect the valve Clapper to ensure freedom of movement. STEP 4 Install the valve in the system so that the direction of water flow is the same as that indicated by the flow direction arrow on the valve body. MODEL NX009 ALARM CHECK VALVE MUST BE INSTALLED IN THE VERTICAL POSITION WITH DIRECTION OF FLOW UP. Use the appropriate gaskets, bolts and/or couplings. Tighten all flange mounting fasteners uniformly as per piping standard. NOTES The Alarm Check Valves must be installed in areas that are accessible and easily visible. STEP 5 Install the trim in accordance with the instructions given in this data sheet. Apply a small amount of thread sealant or tape to external threads of all pipe connections required, sparingly to external threads only. TAKE CARE NOT TO ALLOW ANY COMPOUND, TAPE OR OTHER FOREIGN MATTER INSIDE ANY NIPPLES OR OPENINGS OF THE VALVE OR TRIM COMPONENTS. NOTES It is recommended that provisions be made for viewing the alarm line drain water either by using an open type drain or by locating the main drain outlet in an easily visible area. Suitable provision must be made for disposal of alarm line and system drainage water. Drainage water must be directed so that it will not cause damage or result in dangerous conditions. Assure that all equipments (valves and trims) are adequately heated and protected to prevent freezing and physical damage. Care must be taken when installing in the trim to be certain that they are located with the arrow on the body pointing in the proper direction. The draining pipes must be installed with direction of flow down. STEP 6 Unused alarm connections should be plugged. STEP 7 Optional accessories (Retard Chamber, Water Motor Alarm, Alarm Pressure Switch, etc.) may be connected in accordance with the installation instructions accompanying the equipment. Upon completion of the system side of the installation, the system should be ready for pressurization. STEP 8 If a Water Motor Alarm is NOT to be used, the Alarm Vent Trim must be installed, SMOOTHFLOW AUSTRALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn, NSW 2565 info@smoothflow.com.au

57 Alarm Check Valve TECHNICAL DATA TD01111 PIN: NX nd Edition see Figure DRAIN Ordered separately when Water Motor Alarm is not installed. Figure 6: Alarm Vent Trim ALARM LINE No. Description Qty. Remarks 1 Alarm Pressure Switch 1 Type PS75 2 Bushing ¾ X¼ 1 3 Tee ¾ 1 4 Nipple ¾ X2 (50) 1 5 Optional, Ordered For Retard Chamber 1 Variable Pressure Assembly Systems, NX015 6 Strainer ¾ 1 Type F1191Y 7 Tee ½ 1 8 Nipple (90) ½ X Elbow ½ 2 10 Union ½ 1 Nipple ½ X11¾ 11 (298) 1 12 Vent Fitting With 3 32 Restriction 13 Bushing ¾ X½ 1 UL LISTED STEP 9 It is recommended that a vent connection (which may also be used as an end-of line Inspector s Test Connection), be piped from a cross main or branch line at the point most remote from the alarm valve. The vent line should be connected to the top of a cross main or to the end of a branch line and be located at the highest level of a multi-level installation. The vent connection can be used to bleed off excessive air from the system, and therefore, minimize the possibility of a false alarm due to a transient surge in supply pressure. The contraction/expansion associated with an excessive amount of trapped air could also cause the waterway Clapper to cycle open and shut during an inspector s test or during a discharge by a single sprinkler. SERVICE SETTING When set the Model NX009 Alarm Check Valve system initially or after system operation due to a fire, please perform the following setting procedure. STEP 1 Verify that all drains are closed and that the system is free of leaks. STEP 2 Open the system test valve (the end-of-line Inspector s Test Connection) and any auxiliary vents provided to facilitate removal of air from the system to allow air to escape from the system while it is filling with water. NOTES For proper operation of the wet system and to minimize false alarms, it is important to remove trapped air from the system when filling it with water. Air trapped in the system may also cause intermittent operation of the water motor alarm during a sustained flow of water (such as the flow required by an open sprinkler or the system test valve) (Ref. Design Criteria section). Consider installation of auxiliary vents to facilitate venting. (Ref. Step 9 in Installation section). STEP 3 If desired, close the Alarm Shut-off Valve to prevent local alarms from operating while filling the system. NOTES Alarms and electric panels controlled by an alarm pressure switch installed in the Electric Alarm Panel connection provided in the trim cannot be interrupted. SMOOTHFLOW AUSTRALIA PTY LTD Tel: Techanical Data Sheet TD Heald Road, Ingleburn, NSW 2565 info@smoothflow.com.au

58 Alarm Check Valve TECHNICAL DATA TD01111 PIN: NX nd Edition STEP 4 Slowly open the water supply main control valve until the sound of flowing water just begins and then open the valve one more turn. CAUTION Opening of water supply main control valve will result in water flow from an opening in the system. NOTES Filling the system with water will result in operation of the associated alarms. Thus, notification must first be given to the owner and fire department, central station, or other signal station to which the alarms are connected. STEP 5 Allow the system to completely fill with water. Allow water to flow from the system test valve (the end-of-line Inspector s Test Connection), and any other open vents provided, until all air is exhausted from the system. The outlet has flowed full for at least 15 seconds. Then close the system test valve and all other open vents. STEP 6 Fully open the water supply main control valve. STEP 7 Open the system test valve (the end-of-line Inspector s Test Connection) or Alarm Test Valve, and verify that the system alarms operate. NOTES Notify the proper authorities and all personnel who may be affected that an alarm test is to be performed. STEP 8 Close the system test valve (the end-of-line Inspector s Test Connection) or Alarm Test Valve. UL LISTED STEP 9 Verify that water ceases to flow from the alarm line drain. If water continues to flow, follow the corrective procedure described in the Care and Maintenance section. NOTES The Retard Chamber has a 1/8 (3 mm) diameter Restricted Orifice. Sufficient time must be allowed for drainage of the Retard Chamber and the piping to the Water Motor Alarm. STEP 10 Verify that the flow of water out of the alarm line drain has stopped. Verify the pressure gauge. The pressure gauge on the system side of the Alarm Check valve Clapper should indicate water pressure equal to or greater than the water pressure indicated on the gauge located on the supply side of the clapper. Open the Alarm Shut-off Valve. Verify and secure that all valves are in their normal operating position. Then the alarm check valve system is set and ready for service. NOTES After placing a fire protection system in service, notify the proper authorities and advise those responsible for monitoring proprietary and/or central station alarm, notify those in the affected area that the system is in service. CARE AND MAINTENANCE The following procedures, inspection and testing should be performed as indicated, in addition to any specific requirements of the NFPA. ANY IMPAIRMENT MUST BE IMMEDIATELY CORRECTED. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NFPA, in addition to the standards of any authority having jurisdiction. The installing contractor or manufacturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. It is imperative that the alarm check valve system be maintained on a regular basis. The frequency of the maintenance may vary due to contaminated water supplies, and corrosive water supplies, and corrosive atmospheres. For minimum maintenance requirements, refer to the NFPA that describes care and maintenance of sprinkler systems. In addition, the Authority Having Jurisdiction may have additional inspection, testing and maintenance requirements that must be followed. NOTES Any system maintenance will result in operation of the associated alarm or eliminate SMOOTHFLOW AUSTRALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn, NSW 2565 info@smoothflow.com.au

59 Alarm Check Valve TECHNICAL DATA TD01111 PIN: NX nd Edition the fire-protection capabilities of that system. Thus, notification must first be given to the owner and fire department, central station, or other signal station to which the system are connected. Consideration should be given to employment of a fire patrol in the affected areas. Before closing a fire protection system main control valve for maintenance work on the fire protection systems that it controls, permission to shut down the affected fire protection systems must first be obtained from the proper authorities. MONTHLY INSPECTION: VISUAL EXTERNAL CHECK-UP It is recommended that the following inspections be performed monthly by a qualified Inspection Service. STEP 1 Verify that pressure gauges indicate normal water supply pressures. It is normal for the gauge on the system side of the clapper to register a higher pressure than the gauge on the supply side of the clapper because pressure surges are trapped above the clapper. STEP 2 Check for signs of mechanical damage and/or corrosive activity. If detected, perform maintenance as required or, if necessary, replace the device. STEP 3 Verify that valve and trim are adequately heated and protected from freezing and physical damage. STEP 4 Verify that there is no unwanted leakage from the restricted drain of the Retard Chamber when equipped with variable pressure trim. It is normal for drainage to occur during pressure surges that exceed the capacity allowed through the bypass line trim. UL LISTED STEP 5 Verify that the water supply main control valve is open, and that all valves are in their normal operating position and appropriately secured. QUARTERLY INSPECTION: WATER FLOW ALARM TEST It is recommended that the following checkup of Water Flow Alarm Test be performed quarterly by a qualified Inspection Service. STEP 1 Notify the proper authorities and all personnel who may be affected when the test is to be performed. STEP 2 Open the system test valve (the end-of-line Inspector s Test Connection) and verify that the system alarms operate in accordance with the requirements of the authority having jurisdiction. If freezing weather or other conditions prohibits use of the system test valve, open the Alarm Test Valve in the alarm check valve trim. Verify that the local Water Motor Alarm should be audible. Verify that electric Alarm Pressure Switches should activate properly and within the elapsed time required by the authority having jurisdiction. Verify that electric local alarms should be audible. Verify that remote station alarm signals were received. NOTES Use of the Alarm Test Valve allows testing of alarms without reducing the system pressure. When using the system test valve (the end-of-line Inspector s Test Connection) for the Water Flow Alarm Test, intermittent operation of the water motor alarm may indicate air is trapped in the system. STEP 3 Verify that water is flowing out of the alarm line drain at a rate consistent with the 1/8 (3 mm) diameter drain Restricted Orifice in the Retard Chamber. STEP 4 Close the system test valve (the end-of-line Inspector s Test Connection) or Alarm Test Valve. Verify that water ceases to flow from the alarm line drain. Verify all local alarms stop sounding and electric panels reset. Verify all remote station alarms reset. STEP 5 Clean the Strainer (located at the connection to the Water Motor Alarm, as applicable). Be sure to replace the strainer baskets and tighten the caps securely. NOTES Cleaning of the Strainers after each operation of the alarm is especially important in the case of water supplies (such as lakes and rivers) having a large quantity of suspended matter. A clogged alarm line can prevent operation of the alarm. SMOOTHFLOW AUSTRALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn, NSW 2565 info@smoothflow.com.au

60 Alarm Check Valve TECHNICAL DATA TD01111 PIN: NX nd Edition STEP 6 Verify that the Alarm Shut-off Valve in the alarm line is open, the Alarm Test Valve is closed, and all valves are in their normal operating position and appropriately secured. STEP 7 Notify all authorities responsible for monitoring the installation that the fire protection system has been returned to service. QUARTERLY INSPECTION: MAIN DRAIN TEST It is recommended that the following inspections of Main Drain Test be performed quarterly by a qualified Inspection Service. STEP 1 Notify the proper authorities and all personnel who may be affected when the test is to be performed. STEP 2 Check first to see that adequate drainage is provides for full flow from Main Drain outlet. STEP 3 Record pressure reading from the water supply pressure gauge. STEP 4 Fully open the main drain located on the Alarm Check Valve. When a full flow is developed from the main drain, record the residual pressure from the water supply pressure gauge. STEP 5 Then slowly close the main drain. STEP 6 Compare test results with previous flow information, if deterioration of the water supply is detected, take appropriate steps to restore adequate water supply. STEP 7 Verify that normal water supply pressure has been restored, and that all alarm devices and valves are secured in normal operating position. UL LISTED STEP 8 Notify all authorities responsible for monitoring the installation that the fire protection system has been returned to service. FIVE YEAR INSPECTION: INTERNAL INSPECTION It is recommended that the following inspections of Internal Inspection should be performed every five years by a qualified Inspection Service, unless inspections and tests indicate more frequent internal inspections are required. STEP 1 Notify the proper authorities and all personnel who may be affected when the test is to be performed. Consideration should be given to employment of a fire patrol in the affected areas. STEP 2 Close the water supply main control valve, placing the system out of service. STEP 3 Open the main drain. If necessary, open the system test valve (the end-of-line Inspector s Test Connection) to vent and completely drain the system. STEP 4 Use appropriate wrench to loosen and remove the Cover Plate Bolt, and remove Cover/ Clapper assembly. STEP 5 Inspect the Seat Ring. Wipe away all debris (contaminants, dirt and mineral deposits). Clean any orifices in the Seat Ring that are restricted or plugged by debris. DO NOT USE SOLVENTS OR ABRASIVES. STEP 6 Inspect the Cover/Clapper assembly and Cover Plate Gasket. Test Clapper for freedom of movement. Renew or replace damaged or worn parts as required. CAUTION Never apply any lubricant to seats, gaskets or any internal operating parts of the valve. Petroleum- based grease or oil will damage rubber components and may prevent proper operation. STEP 7 When Internal Inspection of the Alarm Check Valve is complete, reinstall Cover/Clapper Assembly. STEP 8 Place the wet system back in service, Refer to Service Setting section. MAINTENANCE OPERATION: SPRINKLER SYSTEM DRAIN DOWN Draining the sprinkler system must be done in accordance with the following procedure: STEP 1 Close the water supply main control valve, if this has not already been done. STEP 2 Open the remote cross main or branch line vent connection (Ref. Step 9 in Installation SMOOTHFLOW AUSRTALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn, NSW 2565 info@smoothflow.com.au

61 Alarm Check Valve TECHNICAL DATA TD01111 PIN: NX nd Edition section). STEP 3 Open the Main Drain Valve. Check first to see that the drainage water discharge will not cause damage or result in dangerous conditions. STEP 4 Wait until the Supply Pressure Gauge reads zero pressure and the sound of draining water has stopped before performing any maintenance work on the fire protection system. MAINTENANCE OPERATION: REMOVE AND REINSTALL COVER/CLAPPER ASSEMBLY Removing and reinstall the Cover/Clapper Assembly must be done in accordance with the following operation: To remove the Clapper Seal: Use the appropriate wrench to loosen and remove the Clapper Screw, and Clapper Seal Retainer. Remove the Clapper Seal for inspection. If the Clapper Seal shows signs of wear such as cracking, cuts or excessively deep grooves where the Seal contacts the Seat Ring, replace the Clapper Seal. To reinstall the Clapper Seal: Place Clapper Seal over the center of the Clapper Seal Retainer. Position the Retainer (with Seal in place) against Clapper. Replace and tighten the Clapper Screw. DO NOT OVERTIGHTEN. To remove the Clapper and/or the Clapper Shaft: Remove Clapper Bushing to free the Clapper Shaft for removal. Then the Clapper can be removed. To reinstall Cover/Clapper assembly (the Cover Plate, the Clapper, the Clapper Bushing and the Clapper Shaft): Verify that the Clapper Seal and the Cover Plate Gasket are in position and that them are in good condition. Slide the Cover/Clapper assembly into the Alarm Check Valve so that the Clapper Seal contacts the Seal Ring. Adjust Clapper Bushing; insert the Clapper Shaft through the holes. Continue to push the Clapper Shaft through the holes of another Clapper Bushing, adjust Bushings in position. Replace the Cover Plate Bolt. Use the appropriate wrench to evenly cross-tighten all Bolts with a torque of 18 to 20 ft lbs (24.4 to 27.1 N m). DO NOT OVER TIGHTEN. FROM ALARM DRAIN Follow the steps indicated below until water ceases to flow from the alarm line drain. Check for the discontinuation of the leakage after each step is complete. STEP 1 Open the Main Drain Valve. Let the water flow for about 5 seconds and then close the Main Drain Valve. This should flush any loose debris that may have become trapped between the Clapper and the Seat Ring or in the seating area of the Drain Valve. STEP 2 Repeat Step 1 if the rate of continued flow out of the drain was noticeably reduced. STEP 3 Open the Alarm Test Valve and allow water to flow for about 5 seconds before re-closing the valve. This should flush any loose debris that may have become trapped in the seating area of the Alarm Test Valve. STEP 4 Repeat Step 3 if the rate of continued flow out of the drain was noticeably reduced. STEP 5 Determine whether the water is flowing from the alarm port or past the Alarm Test Valve. If the leakage is past the Alarm Test Valve, close the water supply main control valve, and then repair or replace the Alarm Test Valve as necessary. STEP 6 If it appears that the leakage noted in Step 5 is from the alarm port, drain the system. After the system has been drained, remove the Cover/Clapper Assembly. STEP 7 Using a light, check for and remove any debris that may have become lodged within the Seat Ring groove. Inspect the Seat Ring seat for any damage. If the Seat Ring has become dented across the seat then the Alarm Check Valve will have to be replaced. It is impractical to re-face a Seat Ring in the field. STEP 8 Check for and remove any debris that may have become lodged in the Clapper. If a minor imperfection remains in the Clapper, then turn it over after thoroughly cleaning both surfaces with a clean cloth. Replace the Clapper if necessary. Be sure to securely re-tighten the Clapper Screw for the Clapper Seal. STEP 9 Replace the Cover/Clapper Assembly. Return the Alarm Check Valve to operation in accordance with the steps described in the Service Setting section. UL LISTED MALFUNCTION CORRECTED: LEAKAGE MALFUNCTION CORRECTED: CLOGGED SMOOTHFLOW AUSTRALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn, NSW 2565 info@smoothflow.com.au

62 Alarm Check Valve TECHNICAL DATA TD01111 PIN: NX nd Edition ALARM LINE DRAIN If water either does not flow or only dribbles out of the alarm line drain during an alarm test, then it is likely that the Restricted Orifice has become clogged. NOTES A clogged alarm line drain will increase the possibility of a false alarm in the case of a variable pressure system. Remove the Drain Restriction (in the Retard Chamber) and clean it by back flushing. Reinstall the Drain Restriction in the Retard Chamber and reassemble the alarm line. MALFUNCTION CORRECTED: LOSS OF EXCESS SYSTEM PRESSURE In the case of a variable pressure system, the System Pressure Gauge should normally indicate a pressure greater than that shown by the Supply Pressure Gauge. Also, the value should be close to that of the peak supply pressure that has occurred after the system was placed in service. NOTES Loss of excess system pressure will increase the possibility of a false alarm in the case of a variable pressure system. Follow the procedure indicated below to correct a loss of excess system pressure condition. STEP 1 Check for signs of continued leakage from the alarm line drain. If rust stains and/or water deposits indicate that continued leakage has been taking place, take corrective action according to the Malfunction Corrected: Leakage From Alarm Drain in Care and Maintenance section. UL LISTED STEP 2 If there is no signs of continued leakage from the alarm line drain, close the water supply main control valve, slowly open the union in the bypass line. Check for leakage past the Bypass Check Valve. If there is leakage, debris may have become lodged between its clapper and seat. Drain the system in accordance with the prescribed procedure and then clean or replace the Bypass Check Valve as required. Then reassemble the bypass line, and return the fire protection system. STEP 3 If there are no signs of leakage past either the Alarm Check Valve Clapper or the Bypass Check Valve, inspect the sprinkler system for leakage. MALFUNCTION CORRECTED: EXCESS PRESSURE DUE TO THERMAL EXPANSION Wet pipe sprinkler systems subject to ambient temperatures in excess of 100 F/38 C can cause significant increases in system pressure due to the thermal expansion of the water. In particular, a gridded wet-pipe system with a relatively small air pocket and no relief valve can be subjected to an increase of more than 100 psi (6.9 bar), due to an increase in ambient temperature of about 50 F/28 C. As necessary, install a pressure relief valve, in accordance with the requirements of the authority having jurisdiction, to automatically relieve the excess pressure that could otherwise be created in wet-pipe systems that are exposed to significant increases in ambient temperature. MALFUNCTION CORRECTED: FALSE ALARMS If repeated false alarms occur in a variable pressure system:. STEP 1 Check for and correct the cause of continued leakage out the alarm line drain. STEP 2 Check for and clean a clogged alarm line drain. STEP 3 Check for and correct the cause of a loss in excess system pressure. STEP 4 Drain the sprinkler system and refill it in accordance with the steps described in the Service Setting section. MALFUNCTION CORRECTED: INTERMITTENT ALARMS If the Pressure Alarm Switch gives a steady signal, but the Water Motor Alarm generates an intermittent alarm, check for binding in the Water Motor Alarm drive shaft. If the Water Motor Alarm and/or the Pressure Alarm Switch provide an intermittent alarm, it is likely the consequence of an excessive amount of air being trapped within the sprinkler system. Drain down the sprinkler system and refill it in SMOOTHFLOW AUSTRALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn, NSW 2565, info@smoothflow.com.au

63 Alarm Check Valve TECHNICAL DATA TD01111 PIN: NX nd Edition accordance with the steps described in the Service Setting section. A discontinuance of an alarm may also be caused by the Clapper closing due to a sudden drop in supply pressure or the shut-off of a pump in the supply line. These types of problems can only be corrected by maintaining a steady supply pressure. ORDERING PROCEDURE A Product Symbol Number (PSN) shall be specified when ordering the products. Contact your local distributor for availability. STANDARD ORDER NX009 VALVES: Standard NX009 Alarm Check Valve Specify: (specify size inch) Model NX009 Alarm Check Valve with (specify connection style), PSN (specify as follows). PSN X 1 X 2 0 X 1 Alarm Check Valve Size Alarm Check Valve Connection Style 3 Flange X Flange 7 Groove X Groove X 2 STANDARD ORDER NX009 VALVE TRIM: Standard NX009 Alarm Check Valve Trim Specify: Vertical, Opened Drain Galvanized Trim for (specify size inch) (specify connection style) Model NX009 Alarm Check Valve, PSN (specify as follows). PSN X 1 X 2 1 X 1 UL LISTED Alarm Check Valve Size X 2 Alarm Check Valve Connection Style 3 Flange X Flange 7 Groove X Groove ACCESSORIES: Order the following accessories, as applicable: Model NX015 Retard Chamber (required for variable pressure water supply conditions) with NPT connection style: PSN Model NX015 Retard Chamber (required for variable pressure water supply conditions) with ISO Thread connection style: PSN Model NX010 Water Motor Alarm (required for a mechanical water flow alarm) with NPT3/4 Alarm Line Inlet and NPT1 Drain Outlet: PSN Model NX010 Water Motor Alarm (required for a mechanical water flow alarm) with Rc3/4 Alarm Line Inlet and Rc1 Drain Outlet: PSN CONVERSION TABLE Name of Unit Unit Conversion Symbol Factor Millimeter mm 1 in.=25.4 mm Square meter m 2 1 ft 2 = m 2 Liter L 1 gal=3.785 L Cubic decimeter dm 3 1 gal=3.785 dm 3 Cubic meter m 3 1 ft 3 = m 3 Kilogram kg 1 lb=16 ozs.= kg Kilograms per cubic meter Kg/m 3 1 lb/ft 3 = kg/m 3 Pascal Pa 1 psi=6895 Pa Bar bar 1 psi= bar Newton meter N m 1 ft lbs=1.355 N m This! WARNING product must be installed by an experienced, trained installer, in accordance with the instructions provided with each valve. These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage. We reserve the right to change product specifications, designs and standard equipment without notice and without incurring obligations. If you have any questions about the safe installation and use of this device, contact Smoothflo Australia SMOOTHFLOW AUSTRALIA PTY LTD Tel: Technical Data Sheet TD Heald Road, Ingleburn, NSW 2565, info@smoothflow.com.au

64 Water Motor Alarm TECHNICAL DATA TD01211 PIN: NX nd Edition Water Motor Alarm MODEL: NX010 GENERAL DESCRIPTION TECHNICAL SPECIFICATIONS Model NX010 Working Water Pressure Range 5 to 175 psig to 1.2 MPa (0.35 to 12 bar) Shipping Weight 11 lbs 5 kg Alarm Line Inlet NPT3/4 or Rc3/4 * Drain Outlet NPT1 or Rc1 Required Accessories Y-Strainer: 3/4, 20 mesh screen Listings and Approvals UL (United States) *The pipe threads connections accord with ISO7/1. SOUND PRESSURE LEVELS Model NX010 Water Motor Alarm is a mechanical device actuated by a flow of water. It is designed to sound a continuous alarm while a sprinkler system operates. Model NX010 Water Motor Alarm can be used in conjunction with Waterflow Detecting Valves such as alarm check valves, dry pipe valves, deluge valves, and preaction valves to sound a local alarm. And an alarm is required component of every sprinkler system having more than 20 sprinklers. Model NX010 Water Motor Alarm is suitable for mounting to any type of rigid wall and can accommodate a wall thickness range of 2 to 18 inches (50 to 450 mm). Model NX010 Water Motor Alarm utilizes a lightweight impeller design that can produce a high sound pressure level. The Gong, Gong Support, and Water Motor House are made from corrosion resistant aluminum alloys. The polymer Drive Shaft Coupling does not require lubrication, and the Gong is closely fitted to the Gong Support to eliminate the need for a separate cover. Model NX010 Water Motor Alarm can produce a distinctive sound at all working water pressure range. Typical sound pressure levels that can be transmitted by the NX010 Water Motor Alarm are illustrated in Figure 1. OPERATION When a Waterflow Detecting Valve, such as alarm check, dry pipe, deluge and preaction valve, is activated, water flows from the alarm outlet of the Waterflow Detecting Device, through the 3/4 (20 mm) Strainer and alarm line piping, into the Alarm Line Inlet of the Water Motor. From the inlet, the water flows through an Orifice that restricts the flow into a pressurized stream directed onto the Impeller. The water stream impinges on the Impeller and turns the Impeller and Drive Shaft, causing the Striker Arm to rotate. With each rotation, the free-swinging Striker hits the Gong, producing a continuous alarm. After passing through the Water Motor, the water is discharged through a 1 (25 mm) Drain Outlet in the bottom of the Impeller House. The discharged water must be piped through the wall to atmosphere or to a suitable open drain. A minimum of 5 psig (0.035 MPa) is requires at the Orifice to cause a continuous alarm. The Water Motor Alarm produces the required sound pressure levels output. Tel: info@smoothflow.com.au Page 62

65 Water Motor Alarm TECHNICAL DATA TD01211 PIN: NX nd Edition The alarm will sound as long as water is flowing into the system, and may be silenced by closing the alarm control valve provided in the trim of the Waterflow Detecting Valve. The Water Motor Alarm does not have to be reset after an operation. However, if the alarm was silenced during operation, the alarm control valve must be reopened after the fire protection system is restored to service. NOMINAL SOUND PRESSURE (dba) INLET PRESSURE IN BAR (BAR) (1 PSI = BAR) ft (3 m) 20 ft (6 m) 40 ft (12 m) INLET PRESSURE IN POUNDS PER SQUARE INCH (PSI) NOTES: 1. Test performed with background sound pressure level of 55 dba. 2. Model NX010 Water Motor Alarm was mounted 10 feet (3 m) above ground level on 8 inch (200 mm) thick concrete block wall. 3. The microphone is to be located at a distance of 10 feet (3 m), 20 feet (6 m) and 40 feet (12 m) from the Gong and positioned to receive the maximum sound level produced by the device. Figure 1: Typical Sound Pressure Levels In Front Of Model NX010 Water Motor Alarm PRODUCT DESCRIPTION " Drain Outlet /4" Alarm Line Inlet Inlet Orifice ER MOTOR ALARM R LISTED Figure 2: Model NX010 Water Motor Alarm Assembly PARTS Tel: info@smoothflow.com.au Page 63

66 Water Motor Alarm TECHNICAL DATA TD01211 PIN: NX nd Edition No. Part Name Qty. Part No. Material Remarks 1 House Cast Aluminum: A Cover Plate Gasket Cellulose Chloroprene 3 Cover Plate Aluminum: Impeller Delrin 5 Round-Head Screw 6 M5X10 Steel, Zinc Plated 6 Drive Shaft Sleeve /4 Pipe, Galvanized Steel Specify Length Adept Wall Thickness 7 Support Washer Galvanized Steel: G Drive Shaft Aluminum: 2017 Specify Length Adept Wall Thickness 9 Closure Plate Galvanized Steel: G10080 Order Separately 10 Drive Shaft Coupling Lubricomp 189 Ryton 11 Cotter Pin 2 2X12 Steel, Zinc Plated 12 Striker Canvas Phenolic 13 Striker Pin Aluminum: Striker Arm Aluminum: Flat Washer 1 8 S Hex-Head Bolt 1 M8X12 Steel, Zinc Plated 17 Sleeve Coupling Brass: C Coupling Spacer Lubricomp 189 Ryton 19 Gong Support Cast Aluminum: A Set Bolt Washer Lubricomp 189 Ryton 21 Set Bolt Steel, Chrome Plated 22 Gong Aluminum: Sump Plug Brass: C Figure 3: Cross-section View of Striker FEATURES 1. The Water Motor Alarm package includes a Drive Shaft 20-1/16 (510 mm) long for walls 18 (458 mm). A special Drive Shaft length is available for other thickness of walls. 2. The Water Motor Alarm package includes a Drive Shaft Sleeve 18-9/16 (471.5 mm) long for walls 18 (458 mm). A special Drive Shaft Sleeve length is available for other thickness of walls. 3. The package includes the required 3/4 Strainer for installation on the alarm line. OPTIONAL ACCESSORIES ORDER SEPARATELY Closure Plate The Closure Plate is required when the Model NX010 Water Motor Alarm Gong is mounted on an irregularly surfaced wall. It serves to prevent birds from entering the inside of the Gong. The Closure Plate also serves as a mounting plate for sheet metal walls. Tel: info@smoothflow.com.au Page 64

67 Water Motor Alarm TECHNICAL DATA TD01211 PIN: NX nd Edition TRIM DESCRIPTION 2-5/8" (67 mm) 2" (50 mm) MINIMUM 18" (450 mm) MAXIMUM 3-1/4" (83 mm) 3/4" Alarm Line Inlet 4-5/8" (118 mm) 5-3/16" (132 mm) 2-1/4" (57 mm) 8" (204 mm) 1-3/16" (30 mm) 7' 6' Clean-out Sump Plug WATER MOTOR ALARM R LISTED 1-5/8" (41 mm) 1' 2-5/8" (67 mm) 3' 4' 5' 10" (254 mm) MINIMUM 8' 9' 10' 1" Drain Outlet Pipe to atmosphere or suitable open drain. 7' 11' 13' 7' 12' Supply from trim or retard chamber of Waterflow Detecting Valve 14' 2' Lacate Strainer as close as possible to the Waterflow Detecting Valve. NOTES: 1. All installation dimensions are shown at nominal value. All dimensions are in inches and (mm). 2. All trim components are galvanized. 3. Pipe shown in dashed is not included with the standard package of Water Motor Alarm. Figure 4: Typical Trim Installation of Model NX010 Water Motor Alarm BILL OF MATERIALS No. Description Qty. Remarks No. Description Qty. Remarks 1 Nipple 1 1 Galvanized Steel or Brass Pipe 8 Nipple ¾ 1 Galvanized Steel 2 90 Elbow 1 1 Galvanized Steel 9 Union ¾ 1 Galvanized Steel 3 Nipple 1 1 Galvanized Steel Pipe 10 Nipple ¾ 1 Galvanized Steel 4 Wall Plate 1 Galvanized Steel 11 Nipple ¾ 1 Galvanized Steel 5 45 Elbow 1 1 Galvanized Steel 12 Nipple ¾ 1 Galvanized Steel 6 Nipple ¾ 1 Galvanized Steel or Brass Pipe 13 Y-Strainer ¾ 1 20 mesh screen NPT Thread PSN ISO Thread PSN Elbow ¾ 3 Galvanized Steel 14 Nipple ¾ 1 Galvanized Steel Tel: info@smoothflow.com.au Page 65

68 Water Motor Alarm TECHNICAL DATA TD01211 PIN: NX nd Edition DESIGN CRITERIA The Model NX010 Water Motor Alarm must be used in accordance with the following design criteria: 1. The Y-Strainer is to be located at the alarm outlet of the Waterflow Detecting Valve trim, as close as possible to the alarm outlet of the valve being monitored for water flow (or outlet of the retard chamber if used). The location must be easily accessible for cleaning. 2. The Water Motor Alarm must only be mounted to a rigid wall surface, which will not permit the Striker Gong Support to loosen and fall out of alignment. 3. In order to obtain the highest possible sound level, the Water Motor Alarm should be located as close as possible to the Waterflow Detecting Valve. However, any distance and elevation may be used provided that the minimum desired residual pressure, ref. Figure 1, is provided at the inlet to the water motor. The location must be easily accessible for clearing. 4. The alarm line piping from the alarm outlet of the Waterflow Detecting Valve trim to the Water Motor Alarm must be 3/4 size throughout and it must be galvanized steel, brass, or other suitable corrosion resistant material. 5. The alarm line piping must be positioned such that it can be drained back to the Waterflow Detecting Valve trim. 6. The Pipe Plug is to be located vertically below the Alarm Line Inlet to the Water Motor Alarm. It is used for cleaning out all debris (contaminants, dirt and mineral deposits). 7. Piping from the Water Motor Drain Outlet must be a minimum of 1 in size throughout and directed to an open drain, in order to ensure proper drainage for obtaining the maximum sound pressure level. NOTES The Water Motor Alarm Drain may be connected to the main drain of a Waterflow Detecting Valve if a non-spring loaded swing type check valve is installed in a horizontal portion of the Water Motor Alarm drain piping (before its connection to the main drain). 8. In order to minimize the staining which can be created by drain water, it is recommended that the drain piping from the Water Motor be galvanized steel, brass or other suitable corrosion resistant material. 9. Drain water must be directed such that there will be no accidental damage to property or danger to persons when the alarm is operating or thereafter. 10. The alarm line drain (at the Waterflow Detecting Valve) must be maintained at a minimum temperature of 40 F 4 C. 11. A single Water Motor Alarm may be connected to the alarm lines from a maximum of three separate fire protection systems. However, when two or three alarm lines are interconnected, each alarm line must be provided with a 3/4 Y-Strainer and a 3/4 Check Valve with 3/32 orifice. The strainers must be located at the alarm outlet in the trim of each of the Waterflow Detecting Valves. The check valves must be located between each strainer and the interconnection with the alarm line from another system. INSTALLATION WARNING Model NX010 Water Motor Alarms described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the NFPA, in addition to the standards of any other authorities having jurisdictions. Failure to do so may impair the integrity of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or manufacturer should be contacted relative to any questions. 1. Mark the through-wall locations for the centerlines of the Drive Shaft Sleeve and Drain Outlet. The Drain Outlet must be located at least 10 (254 mm) below the Drive Shaft Sleeve, see Figure Cut 1-1/2 (38 mm) (1-7/16 (36.5 mm) Tel: info@smoothflow.com.au Page 66

69 minimum to 1-5/8 (41.3 mm) maximum) diameter hole in the building wall at both locations to accommodate the 3/4 (20 mm) galvanized spacer pipe. The hole through the wall must be level or pitched slightly downward toward the Water Motor. 3. Measure the wall thickness. 4. Cut the non-threaded end of the Drive Shaft Sleeve to a length equal to that of the wall thickness plus 9/16 (14.3 mm). Thread the cut end. 5. Cut the Drive Shaft to a length equal to the wall thickness plus 2-1/16 (52.8 mm). File off all burrs from the cut end of the Drive Shaft and insert the Drive Shaft into the hole of the Drive Shaft Coupling. 6. Slide the Drive Shaft Sleeve over the Drive Shaft and thread the end of the Drive Shaft Sleeve into the Sleeve Coupling. 7. Slide the Closure Plate (if used), over the end of the Drive Shaft Sleeve, up to the back of the Gong. 8. Position the Gong Support assembly on the exterior wall surface by sliding the free threaded end of the Drive Shaft Sleeve into the hole from outside the building. 9. On the inside surface of the wall, slide the Support Washer provided, over the threaded end of the Drive Shaft Sleeve. 10. Remove the plastic thread protectors from the threaded openings in the Houser of the Water Motor (if had). 11. Attach the Water Motor assembly by threading the House onto the threaded end of the Drive Shaft Sleeve. Then the Drive Shaft slide into position of Impeller as the House is threaded onto the Drive Shaft Sleeve. Tighten the threaded into the House hand tight plus 1/8 turn. When the assembly is properly tightened, the Water Motor should be positioned with the 1 (25 mm) Drain Outlet facing downward and the 3/4 (20 mm) Alarm Line Inlet horizontal. See Figures 4. NOTES Use pipe thread sealant sparingly on male threads only. 12. Remove the Gong and rotate the Strikers by hand and verify that them rotate freely TD01211 PIN: NX nd Edition (without any sign of binding). If not, make the necessary adjustments. Then reinstall the Gong. 13. With galvanized, brass or other approved corrosion resistant piping, not less than 3/4 (20 mm) diameter, connect the water motor inlet to the alarm outlet of the Waterflow Detecting Valve. A 3/4 (20 mm) Strainer (included) is required on the alarm line as close as possible to the alarm outlet of the Waterflow Detecting Valve or inlet of the retard chamber if used. The location must be easily accessible for cleaning. 14. The drain outlet of the impeller House must discharge to an open drain. Care shall be taken to keep the drain line clean at all times. Water Motor Alarm TECHNICAL DATA NOTES A water motor drain line that has too many fittings, and or has a very short length of pipe between the 1 (25 mm) outlet and the first elbow in the water motor drain pipe, and or is very long, may result in slow drainage and reduced water motor speed. This condition can be corrected by increasing the drain pipe diameter, increasing the length of pipe to the first elbow, and or pitching the pipe toward the discharge location. 15. Test the Water Motor Alarm by opening the alarm test valve in the trim of the Waterflow Detecting Valve. The alarm must be clear and steady. If not, make the necessary adjustments. NOTES Testing of the Water Motor Alarm may result in operation of other associated alarms. Thus, notification must be given to the owner and the fire department, central control station, or other signal station to which the alarms are connected. MAINTENANCE The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NFPA, in addition to the standards of any authority having jurisdiction. The installing contractor or manufacturer should be contacted relative to any questions. Tel: info@smoothflow.com.au Page 67

70 It is recommended that Water Motor Alarm be inspected, tested, and maintained by a qualified Inspection Service. The Model NX010 Water Motor Alarm does not require any regularly scheduled maintenance. Rotating parts do not require lubrication. For minimum maintenance and inspection requirements, refer to the NFPA that describes care and maintenance of sprinkler systems. In addition, the Authority Having Jurisdiction may have additional maintenance, testing and inspection requirements that must be followed. ANY IMPAIRMENT MUST BE IMMEDIATELY CORRECTED. It is recommended that Water Motor Alarm be periodically operated. At regular intervals, examine and test the Water Motor to ensure that the Inlet Orifice, drain line and Sump are clean and free of obstruction, and that the alarm functions properly. Also, at regular intervals and before disassembly of the Water Motor, clean and inspect the Alarm Line Strainer located at the alarm outlet of the Waterflow Detecting Valve, or the outlet of the retard chamber if used. NOTES Testing of the Water Motor Alarm may result in operation of other associated alarms. Thus, notification must be given to the owner and the fire department, central control station, or other signal station to which the alarms are connected. If the alarm was silenced during operation, the alarm control valve must be reopened immediately after the fire protection system is restored to service. The inspection should be made quarterly or more frequently, as may be necessary in the case of locations subject to vandalism. The Y-Strainer and Sump are to be cleaned out after each operation of the Water Motor Alarm and after the alarm line piping has been drained. If necessary, the Water Motor Alarm should be disassembled for maintenance. Before proceeding with disassembly of the Water Motor Alarm, notify the Authority Having Jurisdiction and occupants of the area covered by the system affected. Take all appropriate precautions. THE WATER MOTOR ALARM WILL BE DISABLED DURING DISASSEMBLY. TD01211 PIN: NX nd Edition WATER MOTOR DISASSEMBLY 1. Isolate the Water Motor Alarm by closing the alarm line valve in the trim of the Waterflow Detecting Valve (Refer to appropriate technical data for the system used). 2. Remove the Sump Plug. 3. Remove all Round-Head Screws (M5X10), from the water motor Cover Plate. 4. Separate the Cover Plate and the Cover Plate Gasket from the House. 5. Remove the Impeller. Inspect and if necessary, carefully clean the Inlet Orifice in the House, with a wire or pipe cleaner brush. Flush the Inlet Orifice way and drain line with water or compressed air. Water Motor Alarm TECHNICAL DATA WATER MOTOR RE-ASSEMBLY 1. Reinstall the Sump Plug. 2. Reinstall the Impeller. 3. Replace Cover Plate Gasket, and attach Cover Plate, by using Round-Head Screws (M5X10). 4. Open the alarm line valve. 5. Test the Water Motor Alarm. 6. When test is complete and Water Motor Alarm operation is satisfactory, place the alarm line valve in the proper alarm position. Reset and return the affected systems to service. ORDERING PROCEDURE A Product Symbol Number (PSN) shall be specified when ordering the products. Contact your local distributor for availability. STANDARD ORDER NX010 WATER MOTOR ALARM: Standard NX010 Water Motor Alarm Specify: Model NX010 Water Motor Alarm with (specify connection style), PSN (specify as follows). PSN X 1 00 X Connection Style Alarm Line Inlet NPT3/4 Drain Outlet NPT1 Alarm Line Inlet Rc3/4 Drain Outlet Rc1 Tel: info@smoothflow.com.au Page 68

71 ACCESSORIES: Order the following accessories, as applicable: Y-Strainer with NPT3/4 connection style (the standard package already includes a required 3/4 Y-Strainer) PSN Y-Strainer with Rc3/4 connection style (the standard package already includes a required 3/4 Y-Strainer) PSN Closure Plate (required for the Alarm Gong mounted on irregularly surfaced wall or sheet metal wall) PSN Water Motor Alarm TECHNICAL DATA TD01211 PIN: NX nd Edition CONVERSION TABLE Name of Unit Unit Conversion Symbol Factor Millimeter mm 1 in.=25.4 mm Square meter m 2 1 ft 2 = m 2 Liter L 1 gal=3.785 L Cubic decimeter dm 3 1 gal=3.785 dm 3 Cubic meter m 3 1 ft 3 = m 3 Kilogram kg 1 lb=16 ozs.= kg Kilograms per cubic meter Kg/m 3 1 lb/ft 3 = kg/m 3 Pascal Pa 1 psi=6895 Pa Bar bar 1 psi= bar Newton meter N m 1 ft lbs=1.355 N m This! WARNING product must be installed by an experienced, trained installer, in accordance with the instructions provided with each valve. These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage. We reserve the right to change product specifications, designs and standard equipment without notice and without incurring obligations. If you have any questions about the safe installation and use of this device, contact Nanjing Fire Protection Technology Co., Ltd. P.C , 599 Zhushan Road, Jiangning District, Nanjing, R. P.China Nwww.smoothflow.com.au Tel: info@smoothflow.com.au Page 69

72 LANDING VALVES SMOOTHFLOW AUSTRALIA SPECIFICATIONS Water Mark Certificate to: AS Licence Number: WM Working Pressure: 1400KPA Body & Seal Test: 2700KPA Pressure Retention Test: 3200KPA SMOOTHFLOW CODE MODEL SIZE H (mm) W (mm) INLET OUTLET V-LV-65-NSW SFKX06-175N 65NB mm BSP NSW THREAD / 3 GR V-LV-65-STORZ SFKX06-175S 65NB STORZ CAPS FOR LANDING VALVES STORZ cap NSW 5V cap QRT TEL: INFO@SMOOTHFLOW.COM.AU Page70

73 BOOSTER HEAD SPECIFICATIONS Materials All components: 304 Stainless steel SMOOTHFLOW AUSTRALIA Single Head Booster 80mm Grooved Connection Pressure Test Working Pressure: Body: Seal Test: 1400KPA 2800KPA 2100KPA Dual Head Booster Back connection, 100mm grooved Dual Head Booster Bottom connection, 100mm grooved CAPS FOR BOOSTER HEAD NSW 5V QRT TEL: Page 71

74 STORZ ADAPTOR SMOOTHFLOW AUSTRALIA FORGED STORZ ADAPTORS FOR Landing Valves And Booster Heads SPECIFICATIONS THREADS AVAILABLE: DN65 Male thread Forged Female thread Material: Aluminium Alloy NSW FBT Rubber: EPDM CFA QRT SART TEL: Page 72

75 460 FIRE HOSE REELS FIXED & SWIVEL SMOOTHFLOW AUSTRALIA Main Components Fixed Hose Reel Swivel Hose Reel Hose - Length x Diameter 36m x19mm 36m x 19mm SAL-Global Approved To AS/NZS 1221 AS/NZS 1221 Min. Inlet Pressure 220Kpa, 0.45L/S, 220Kpa, 0.45L/S, Drum Side Plates Mild Steel/UV Polyester Coated Mild Steel/UV Polyester Coated Waterway Assembly Galvanised Mild Steel Galvanised Mild Steel Ball Valve Assembly Brass Body/Zinc Plated Mild Steel Handle Nozzle Assembly Brass Brass Brass Body/Zinc Plated Mild Steel Handle Union Galvanised Malleable Iron Galvanised Malleable Iron Hose Guide Assembly Zinc Plated Mild Steel Zinc Plated Mild Steel Mounting Shoe Galvanised/Zinc Plated Mild Steel Galvanised/Zinc Plated Mild Steel Package Carton, 490 x 300 x 550 PRODUCT CODE HR36M19MM-F HR36M19MM-S MAIN FEATURES Special ball valve shut off device to ensure the max flow. Solid brass hose nozzle; Quick and easy installation APPLICATION: The fire hose reels are suitable for fires of class A paper, textile, wood, plastic and rubber. Tel: info@smoothflow.com.au Page 73

76 ACCESSORIES FOR FIRE PROTECTION SMOOTHFLOW AUSTRALIA CABINET FOR HOSE REEL --- FLAT PACK Dimensions: 1000H x 760W x 380D Power Coated In Red Wall Mounted Freestanding CABINET FOR FIRE SPRINKLER CONTROL VALVE --- FLAT PACK Dimensions: 785H x 560W x 300D Power Coated In Red Wall Mounted Only 003 Lock CABINET FOR FIRE SPRINKLER CONTROL VALVE --- FLAT PACK Dimensions: 680H x 450W x 250D Power Coated In Red Wall Mounted Only 003 Lock TEL: info@smoothflow.com.au Page 74

77 GALVANISED PIPES SMOOTHFLOW AUSTRALIA LIGHT WALL PIPE ROLL GROOVED SCH10 HOT DIP GALVANISED SPECIFICATIONS AND FEATURES Schedule 10 Light wall Sprinkler Pipe meets or exceeds the following: FM Certificate No: UL Certificate No: EX15475 Conforms to the Requirements of AS & AS4118 Manufactured to ASTM A135, Grade A Roll Grooved on Both Ends Nominal Size Nominal O.D (mm) Nominal I.D (mm) Nominal Wall (mm) Nominal Weight (kg/m) 32NB NB NB NB NB NB NB NB TEL: INFO@SMOOTHFLOW.COM.AU Page 75

78 GALVANISED PIPES SMOOTHFLOW AUSTRALIA MEDIUM PIPE ROLL GROOVED SCH40 HOT DIP GALVANISED SPECIFICATIONS AND FEATURES Schedule 40 Medium HDG Pipe meets or exceeds the following: FM Certificate No: UL Certificate No: EX15475 Conforms to the Requirements of AS1074, AS & AS4118 Manufactured to ASTM A135, Grade A Roll Grooved on Both Ends Nominal Size Nominal O.D (mm) Nominal I.D (mm) Nominal Wall (mm) Nominal Weight (kg/m) 25NB NB NB NB NB NB NB NB TEL: INFO@SMOOTHFLOW.COM.AU Page 76

79 SPRINKLER PIPES SMOOTHFLOW AUSTRALIA MEDIUM WALL PIPES FOR SPRINKLER SYSTEMS SPECIFICATIONS AND FEATURES Schedule 40 Medium Wall Sprinkler Pipe meets or exceeds the following: FM Certificate No: UL Certificate No: EX15475 Conforms to the Requirements of AS1074, AS & AS4118 Manufactured to ASTM A135, Grade A Threaded on Both Ends for the sizes up to 50mm. plain ends for the size 65mm and above. Nominal Size Nominal O.D (mm) Nominal I.D (mm) Nominal Wall (mm) Nominal Weight (kg/m) 25NB NB NB NB NB NB NB NB TEL: INFO@SMOOTHFLOW.COM.AU Page 77

80 PIPE: 100MM BRANCH FOR BOOSTER HEAD: 80 CONNECTION FOR TAP: 20MM BSP CONNECTION: 8MM FOR PRESSURE GAUGE 114.3mm RG mm RG mm BSP Female length: 10-20mm 88.9mm RG 20mm BSP Female length 10-20mm 114.3mm RG SMOOTHFLOW AUSTRALIA UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN MILLIMETERS SURFACE FINISH: TOLERANCES: LINEAR: ANGULAR: DRAWN CHK'D APPV'D MFG Q.A NAME FINISH: SIGNATURE DATE HDG 1/12/2013 MATERIAL: MILD STEEL DEBUR AND BREAK SHARP EDGES TITLE: DWG NO. DO NOT SCALE DRAWING Fabrication Pipe for Hydrant Booster Assembly 100NB. Connection for Booster Check Valve DWG-PI B-G REVISION SMOOTHFLOW AUSTRALIA A4 WEIGHT: SCALE:1:5 SHEET 1 OF 1

81 114.3mm RG 88.9mm RG mm RG 114.3mm RG SMOOTHFLOW 625 AUSTRALIA UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN MILLIMETERS SURFACE FINISH: TOLERANCES: LINEAR: ANGULAR: FINISH: HDG DEBUR AND BREAK SHARP EDGES DO NOT SCALE DRAWING REVISION SMOOTHFLOW AUSTRALIA DRAWN CHK'D APPV'D NAME SIGNATURE DATE 1/12/2013 TITLE: Fabrication Pipe for Hydrant Booster Assembly 100NB. Connection for Landing Valve MFG Q.A MATERIAL: MILD STEEL DWG NO. DWG-PI LV-G A4 WEIGHT: SCALE:1:5 SHEET 1 OF 1

82 107 2 x GR114mm 2 x GR 89mm 575 8mm BSP SMOOTHFLOW AUSTRALIA mm BSP PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF <INSERT COMPANY NAME HERE>. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF <INSERT COMPANY NAME HERE> IS PROHIBITED. NEXT ASSY APPLICATION USED ON DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL ANGULAR: MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL MATERIAL FINISH MILD STEEL HDG DO NOT SCALE DRAWING DRAWN CHECKED ENG APPR. MFG APPR. Q.A. COMMENTS: NAME DATE KEVIN ZHENG 3/1/2014 SIZE A SMOOTHFLOW AUSTRALIA Title SCALE:1:5 100mm pipe fabrication. used for booster connection DWG. NO. WEIGHT: DWG-PI B SHEET 1 OF 1 REV.

83 B B mm 沟槽连接 ± ± DETAIL C SCALE 1 : 2 SMOOTHFLOW ±0.50 AUSTRALIA SECTION B-B SCALE 1 : 5 C 法兰焊接在钢管上 : 1. 钢管厚度 : >=5mm 2. 法兰厚度 : 15mm 3. 试压 : 16KG 4. 热镀锌 18 x 8 UNLESS OTHERWISE SPECIFIED: FINISH: DIMENSIONS ARE IN MILLIMETERS SURFACE FINISH: TOLERANCES: LINEAR: ANGULAR: DRAWN CHK'D APPV'D MFG Q.A NAME Kevin SIGNATURE HOT DIP GALVANIZED DATE 31/7/2014 MATERIAL: MILD STEEL DEBUR AND BREAK SHARP EDGES DO NOT SCALE DRAWING SMOOTHFLOW AUSTRALIA TITLE: DWG NO. REVISION PIPE WELDED WITH FLANGE (T/E) FOR HRDRANT RISER DWG-PI-R-1000 WEIGHT: SCALE:1:1 SHEET 1 OF 1

84 100mm 沟槽连接 D D ± ± DETAIL E SCALE 2 : 5 SMOOTHFLOW ±0.50 AUSTRALIA SECTION D-D SCALE 1 : 6 E 法兰焊接在钢管上 : 1. 钢管厚度 : >=5mm 2. 法兰厚度 : 15mm 3. 试压 : 16KG 4. 热镀锌 18 x 8 UNLESS OTHERWISE SPECIFIED: FINISH: DIMENSIONS ARE IN MILLIMETERS SURFACE FINISH: TOLERANCES: LINEAR: ANGULAR: DRAWN CHK'D APPV'D MFG Q.A NAME Kevin SIGNATURE HOT DIP GALVANIZED DATE 31/7/2014 MATERIAL: MILD STEEL DEBUR AND BREAK SHARP EDGES DO NOT SCALE DRAWING SMOOTHFLOW AUSTRALIA TITLE: DWG NO. REVISION PIPE WELDED WITH FLANGE (T/E) FOR HRDRANT RISER DWG-PI-R-1200 WEIGHT: SCALE:1:1 SHEET 1 OF 1

85 F F ± ± DETAIL G SCALE 1 : ± mm 沟槽连接 SMOOTHFLOW SECTION F-F SCALE 1 : 7 AUSTRALIA G 法兰焊接在钢管上 : 1. 钢管厚度 : >=5mm 2. 法兰厚度 : 15mm 3. 试压 : 16KG 4. 热镀锌 18 x 8 UNLESS OTHERWISE SPECIFIED: FINISH: DIMENSIONS ARE IN MILLIMETERS SURFACE FINISH: TOLERANCES: LINEAR: ANGULAR: DRAWN CHK'D APPV'D MFG Q.A NAME Kevin SIGNATURE HOT DIP GALVANIZED DATE 31/7/2014 MATERIAL: MILD STEEL DEBUR AND BREAK SHARP EDGES DO NOT SCALE DRAWING SMOOTHFLOW AUSTRALIA TITLE: DWG NO. REVISION PIPE WELDED WITH FLANGE (T/E) FOR HRDRANT RISER DWG-PI-R-1400 WEIGHT: SCALE:1:1 SHEET 1 OF 1

86 165.1mm GR B B 8mm BSP mm BSP SECTION B-B SCALE 1 : 4 150mm GR 4 x 80mm GR 150mm Pipe 80mm Pipe SMOOTHFLOW AUSTRALIA UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN MILLIMETERS SURFACE FINISH: TOLERANCES: LINEAR: ANGULAR: FINISH: DEBUR AND BREAK SHARP EDGES DO NOT SCALE DRAWING REVISION SMOOTHFLOW AUSTRALIA DRAWN CHK'D APPV'D NAME SIGNATURE DATE Kevin 16/3/2014 TITLE: Pipe fabrication. 150mm NB. 4 Booster Head MFG Q.A MATERIAL: mild Steel Pipe DWG NO. DWG-PI-B A4 WEIGHT: SCALE:1:10 SHEET 1 OF 1

87 150mm GR B A mm GR 133 A 4 x 80mm GR SECTION B-B SCALE 1 : 4 SMOOTHFLOW AUSTRALIA B 625 UNLESS OTHERWISE SPECIFIED: FINISH: DIMENSIONS ARE IN MILLIMETERS SURFACE FINISH: TOLERANCES: LINEAR: ANGULAR: HDG DEBUR AND BREAK SHARP EDGES DO NOT SCALE DRAWING REVISION SMOOTHFLOW AUSTRALIA SECTION A-A SCALE 1 : 2 DRAWN CHK'D APPV'D MFG Q.A NAME SIGNATURE DATE MATERIAL: mild steel pipe TITLE: DWG NO. 150mm pipe fabrication for hydrant booster. 4 landing valves will be connected on DWG-PI-LV WEIGHT: SCALE:1:5 SHEET 1 OF 1

88 PRODUCTS FOR BUILDING SERVICES SMOOTHFLOW AUSTRALIA COMBINED SUCTION/BOOSTER ASSEMBLIES SIZE Description 100 NB 2 point suction / booster assembly 150 NB 4 point suction / booster assembly 200 NB 6 point suction / booster assembly 200, 250 and 300mm suction / booster assemblies are also available. Comply to AS COMBINED SUCTION / BOOSTER ASSEMBLY C/W DDCV BACKFLOW PREVENTION SIZE Description 100 NB 2 point suction / booster assembly 150 NB 4 point suction / booster assembly 200 NB 6 point suction / booster assembly info@smoothflow.com.au Tel: Page 86

89 PRODUCTS FOR BUILDING SERVICES SMOOTHFLOW AUSTRALIA VERTICAL HYDRANT BOOSTER ASSEMBLIES TO CUSTOMER DESIGN SIZE Description 100 NB 2 point suction / booster assembly 150 NB 4 point suction / booster assembly 200 NB 6 point suction / booster assembly TWIN HYDRANT RISER ASSEMBLY HYDRANT BOOSTER SPRINKLER BOOSTER info@smoothflow.com.au Tel: Page 87

90 PRODUCTS FOR BUILDING SERVICES SMOOTHFLOW AUSTRALIA BULL HEAD TEE 100 X 80 Grooved REDUCING TEE 100 X 80 Grooved END-RUN 100 x 80 Grooved LANDING VALVE BOOSTER CONNECTION GROOVED COUPLINGS ELBOWS AND OTHER GROOVED FITTINGS info@smoothflow.com.au Tel: Page 88

91 PRODUCTS FOR BUILDING SERVICES SMOOTHFLOW AUSTRALIA GALVANISED PIPES WITH GROOVED ENDS PIPE CUTTING AND GROOVING SERVICES Tel: Page 89

92 PEAR HANGERS SMOOTHFLOW AUSTRALIA ADJUSTABLE BAND PEAR HANGER Size Range: Material: Approval: Finish: 15mm to 200mm Pre-Galvanised Steel UL/cUL Pre-Galvanised SmoothFlow Code Pipe Size (NB) H (mm) A (mm) W (mm) D (mm) Thickness Max. Rec. Load (Kg) PEARH015 15mm (1/2 ) PEARH020 20mm (3/4 ) PEARH025 25mm (1 ) PEARH032 32mm (1-1/4 ) PEARH040 40mm (1-1/2 ) PEARH050 50mm (2 ) PEARH065 65mm (2-1/2 ) PEARH080 80mm (3 ) PEARH mm (4 ) PEARH mm (5 ) PEARH mm (6 ) PEARH mm (8 ) THREAD RODS, NUTS AND FLAT WASHERS Zinc Plated SmoothFlow Code Product Name Size Length (mm) Note TROD08 8mm 2000 TROD10 10mm 2000 Thread Rod TROD12 12mm 2000 TROD16 16mm 2000 NUT08 8mm 14mm spanner NUT10 10mm 17mm spanner Nuts NUT12 12mm 19mm spanner NUT16 16mm 24mm spanner WASH08 8mm OD: 16mm WASH10 10mm OD: 20mm Flat Washer WASH12 12mm OD: 24mm WASH16 16mm OD: 30mm Tel: info@smoothflow.com.a page 90

93 PEAR HANGERS SMOOTHFLOW AUSTRALIA STRUT PIPE CLAMP Material: Steel Size:15mm(1/2 ) - 200mm (8 ) Electro-Zinc Plated Four Piece Design Quick Installation SmoothFlow Max Rec. Pipe Size Bolts Gauge Code Load (Kg) SC015 15mm (1/2 ) 175 M6 x SC020 20mm (3/4 ) 250 M6 x SC025 25mm (1 ) 250 M6 x SC032 32mm (1-1/4 ) 250 M6 x SC040 40mm (1-1/2 ) 250 M6 x SC050 50mm (2 ) 250 M6 x SC065 65mm (2-1/2 ) 350 M6 x SC080 80mm (3 ) 350 M6 x SC mm (4 ) 350 M8 x SC mm (5 ) 350 M8 x SC mm (6 ) 350 M8 x SC mm (8 ) 350 M8 x UNISTRUT CHANNEL STEEL Slotted Pre-galvanised 2.5mm thick material Length: 10 (3048mm) SmoothFlow Code: STRUT4141 & STRUT4121 SPRING NUTS Used on Unistrut Channel Steel Pre-galvanised Sizes from 8mm to 16mm. SmoothFlow Code: S-NUT08 to S-NUT16 ANGLE STEEL 30x30x3 Slotted Pre-Galvanised 3mm Thick Material Length: 2m SmoothFlow Code: A-STEEL Tel: info@smoothflow.com.au page 91

94 ACCESSORIES FOR FIRE PROTECTION SMOOTHFLOW AUSTRALIA PRESSURE GAUGE --- LIQUID FILLED DIAL: 150mm Stainless steel case, liquid filled Radial connection: ½ BSP Mark: from -100kpa to 3000kpa DIAL: 100mm Stainless steel case, liquid filled Radial connection: ½ BSP Mark: from -100kpa to 3000kpa DIAL: 63mm Stainless steel case, liquid filled Radial connection: ¼ BSP Mark: from 0kpa to 2000kpa 003 PADLOCK Dimensions: 30x28x13.5mm Shackle Diameter: 5mm Come with one key only TEL: Page 92

95 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF <INSERT COMPANY NAME HERE>. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF <INSERT COMPANY NAME HERE> IS PROHIBITED. NEXT ASSY APPLICATION USED ON DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL ANGULAR: MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL MATERIAL FINISH PAINTED DO NOT SCALE DRAWING NAME DATE DRAWN KEVIN ZHENG CHECKED ENG APPR. MFG APPR. Q.A. COMMENTS: SIZE A SMOOTHFLOW AUSTRALIA Title SCALE:1:20 DWG. NO. STAND ASSEMBLY FOR HOSE REEL CABINET WEIGHT: DWG-S-HRC-00 SHEET 1 OF 1 REV.

96 x4 120 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF <INSERT COMPANY NAME HERE>. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF <INSERT COMPANY NAME HERE> IS PROHIBITED. NEXT ASSY APPLICATION USED ON DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL ANGULAR: MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL MATERIAL FINISH POWER COATING RAL 3000 SIGNAL RED DO NOT SCALE DRAWING DRAWN CHECKED ENG APPR. MFG APPR. Q.A. COMMENTS: NAME KEVIN ZHENG 1/2/2014 STEEL FABRICATION DATE SIZE A SMOOTHFLOW AUSTRALIA Title SCALE:1:20 DWG. NO. STAND FOR HOSE REEL DRILLING SUITS SMOOTHFLOW BRAND. WEIGHT: DWG-HR-S-01 SHEET 1 OF 1 REV.

97 WET ALARM VALVE SMOOTHFLOW AUSTRALIA The pumps and pumping stations and oil separators for building service: Please refer to separate brochures for details. Tel: Page 95

98 PACKAGED SOLUTIONS FOR FIRE PROTECTION, PLUMBING AND BUILDINGS

UL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response

UL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response SPRINKLER HEADS SMOOTHFLOW AUSTRALIA SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed RESPONSE Quick response Standard response COLOURS Natural brass Chromed Power coated white TEMPERATURE

More information

Automatic Sprinklers

Automatic Sprinklers UPRIGHT SPRINKLERS AND PENDENT SPRINKLERS MODEL: BZ003 / BZ004 / BZ005 / BZ006 STANDARD SPRAY, STANDARD / QUICK RESPONSE, 5 / 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD GENERAL DESCRIPTION The BZ003/BZ004

More information

MODEL: FA003U FA004U FA005P FA006P STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD

MODEL: FA003U FA004U FA005P FA006P STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2 CONNECTING THREAD UPRIGHT SPRINKLERS AND PENDENT SPRINKLERS MODEL: FA003U FA004U FA005P FA006P STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD GENERAL DESCRIPTION The FA003U/FA004U

More information

Automatic Sprinklers

Automatic Sprinklers CONCEALED PENDENT SPRINKLERS MODEL: BZ007 / BZ008 STANDARD SPRAY, STANDARD / QUICK RESPONSE, 5 / 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD GENERAL DESCRIPTION The BZ007/BZ008 Standard/Quick Response

More information

MODEL: FA007C FA008C STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD WRENCH FLAT

MODEL: FA007C FA008C STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2 CONNECTING THREAD WRENCH FLAT Tel: 00-44-8450751042 Fax: 00-44-8450751043 Email: info@fireguard-uk.com 2nd FLOOR 145-157 ST.JOHNS STREET LONDON EC1V 4PY UNITED KINGDOM CONCELED PENDENT SPRINKLERS MODEL: F007C F008C STNDRD SPRY, STNDRD

More information

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description Worldwide Contacts www.tyco-fire.com Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description TYCO Series DS-1 Stainless

More information

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage Worldwide Contacts www.tyco-fire.com Series 2.8,.2, 5.6, 8.0 K-Factor Upright, Pendent, Recessed Pendent Sprinklers Quick Response, Stard Coverage General Description IMPORTANT Always refer to Technical

More information

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description Worldwide Contacts www.tyco-fire.com Series 2.8,.2,.6, 8.0 K-Factor Upright, Pendent, Recessed Pendent Sprinklers Quick Response, Stard Coverage General Description The TYCO Series, 2.8,.2,.6, 8.0 K-factor,

More information

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description Worldwide Contacts www.tyco-fire.com Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K and Pendent Extended Coverage Light and Ordinary Hazard General Description TYCO Series EC-11 and EC-14 Extended

More information

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved Worldwide Contacts www.tyco-fire.com Model TJR Resilient-Seated Gate Valves Outside Screw and Yoke General Description TYCO Model TJR Resilient-Seated Gate Valves are used in Fire Protection Systems for

More information

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data Worldwide Contacts www.tyco-fire.com Series TY-B 5.6 K-factor Standard Response, Standard Coverage General Description described in this data sheet are standard response - standard coverage, decorative

More information

Sprinkler Identification Numbers

Sprinkler Identification Numbers Worldwide Contacts www.tyco-fire.com Series TY-FRB 5.6 K-factor Horizontal Quick Response, Standard Coverage General Description IMPORTANT Always refer to Technical Data Sheet TFP700 for the INSTALLER

More information

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description LFII Residential Horizontal Sidewall

More information

Sprinkler Identification Number (SIN)

Sprinkler Identification Number (SIN) Worldwide Contacts www.tyco-fire.com Series DS-3 Dry-Type Sprinklers 11.2K Horizontal Sidewall Standard Response, Extended Coverage General Description TYCO Series DS-3 Dry-Type Sprinklers, 11.2K Horizontal

More information

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems General Description The TYCO RAPID RESPONSE Series

More information

Sprinkler Identification Numbers

Sprinkler Identification Numbers Worldwide Contacts www.tyco-fire.com Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K and Pendent Extended Coverage Light and Ordinary Hazard General Description Extended Coverage and Pendent Sprinklers

More information

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description The TYCO RAPID RESPONSE Series LFII

More information

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts. Worldwide Contacts www.tyco-fire.com Model EC-HS 80 K-factor, Quick Response Extended Coverage Horizontal Sidewall Sprinklers Installations per VdS CEA 400, Annex E, LH/OH General Description The Model

More information

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description Pendent Sprinklers (TY2235)

More information

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16 (42,7 mm) CROSS SECTION Worldwide Contacts www.tyco-fire.com Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K and Pendent Extended Coverage Light and Ordinary Hazard General Description Extended Coverage and Pendent Sprinklers

More information

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description Pendent Sprinklers (TY2235)

More information

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

WRENCH FLATS 1/2 NPT. 7/16 (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 4.4 K-factor Horizontal Sidewall Wet Pipe Systems General Description LFII Residential Horizontal Sidewall Sprinklers

More information

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description TYCO 5.6K Institutional Pendent and Horizontal Sidewall (HSW) Sprinklers

More information

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential 4.9 K-factor Pendent Sprinkler Wet Pipe and Dry Pipe Systems General Description TYCO RAPID RESPONSE Series Recessed Pendent

More information

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems General Description The TYCO RAPID RESPONSE Series

More information

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description Worldwide Contacts www.tyco-fire.com Series TY-FRB 5.6 K-factor Horizontal Quick Response, Standard Coverage General Description described in this data sheet are quick response -standard coverage, decorative

More information

* Temperature rating is FIGURE K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS

* Temperature rating is FIGURE K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS Worldwide Contacts www.tyco-fire.com Series TY-FRB.6 K-factor Horizontal Quick Response, Standard Coverage General Description The Series TY-FRB,.6 K-factor, Horizontal described in this data sheet are

More information

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for

More information

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description The TYCO RAPID RESPONSE Series LFII

More information

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description Worldwide Contacts www.tyco-fire.com Model SW-20 and SW-24 11.2 K-factor Extended Ordinary Hazard Horizontal Sidewall s (Standard ) General Description 11.2 K-factor, Extended Ordinary s, Standard are

More information

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential 4.9 K-factor Pendent Sprinkler Wet Pipe and Dry Pipe Systems General Description TYCO RAPID RESPONSE Series Recessed Pendent

More information

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

WRENCH FLATS 1/2 NPT. 7/16 (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems General Description The TYCO RAPID RESPONSE Series

More information

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response)

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) Worldwide Contacts www.tyco-fire.com Model SW-20 and SW-24 11.2 K-factor Extended Ordinary Hazard Horizontal Sidewall s (Standard ) General Description 11.2 K-factor, Extended Ordinary Sprin klers, Standard

More information

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description Worldwide Contacts www.tyco-fire.com Series.8,.,.6, 8.0 K-Factor Upright,, Sprinklers Quick Response, Stard Coverage General Description The TYCO Series.8,.,.6, 8.0 K-factor Upright,, Sprinklers described

More information

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description Worldwide Contacts www.tyco-fire.com Series TY-B.6 K-factor Standard Response, Standard Coverage General Description The TYCO Series TY-B,.6 K-factor, described in this technical data sheet are standard

More information

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS * Worldwide Contacts www.tyco-fire.com Series TY-FRB 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Quick Response General Description Intermediate Level Sprinklers are automatic

More information

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

WRENCH FLATS NPT 1/2 7/16 (11,1 mm) NOMINAL MAKE-IN. 1-1/2 (38,1 mm) 2-3/16 (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN. Worldwide Contacts www.tyco-fire.com Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall s Quick and Standard Response (Light Hazard) General Description TYCO Series TY-FRB 5.6 and

More information

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description Worldwide Contacts www.tyco-fire.com Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description The Series TY-B, 5.6 and 8.0 K-factor Upright

More information

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8 City of Ottawa Project No. CR006230 Page 1 of 8 PART 1 - GENERAL 1.1 Reference Standards.1 Conform to the following:.1 Provincial and municipal building and fire regulations as approved by Provincial Fire

More information

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description Technical Services 800-381-9312 +1-401-781-8220 www.tyco-fire.com Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General

More information

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description Worldwide Contacts www.tyco-fire.com Series TY-B 5.6 K-factor Standard Response, Standard Coverage General Description described in this technical data sheet are standard response, standard coverage decorative

More information

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Model/Sprinkler Identification Number JULY, 2011 WARNINGS Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series EC-11 & EC-14 11.2 and 14.0 K-factor Extended Coverage (Light and Ordinary Hazard) Upright, Pendent, and Recessed Pendent Sprinklers

More information

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS Worldwide Contacts www.tyco-fire.com Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description The Series TY-B, 5.6 and 8.0 K-factor Upright

More information

esfr dry pendent sprinkler Vk501 (k14.0)

esfr dry pendent sprinkler Vk501 (k14.0) September 13, 2012 Sprinkler 122a 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK501 is a fast response fusible element type sprinkler designed for use in storage

More information

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description Worldwide Contacts www.tyco-fire.com Series EC-8 8.0 K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description Pendent Sprinklers are decorative glass bulb sprinklers

More information

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description Sprinklers (TY2284) are decorative, fast response, fusible solder sprinklers

More information

esfr dry pendent sprinkler Vk502 (k14.0)

esfr dry pendent sprinkler Vk502 (k14.0) Page 1 of 11 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK502 is a fast response fusible element type sprinkler designed for use in storage areas subject to freezing

More information

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

ESCUTCHEON PLATE SEATING 3/4 NPT SURFACE. 1-1/2 (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 6.9 K-factor, Pendent/Recessed Pendent/Concealed, NFPA 13 Optimized Wet Pipe Systems General Description The TYCO

More information

Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage General Description

Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage General Description Worldwide Contacts www.tyco-fire.com Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage General Description TYCO Series DS-1 Dry-Type Sprinklers,

More information

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description Worldwide Contacts www.tyco-fire.com Series TY-B 2.8,.6, 8.0 K-factor Upright, Pendent, Recessed Pendent Sprinklers Stard Response, Stard Coverage General Description TYCO Series TY-B, 2.8,.6, 8.0 K-factor,

More information

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description Worldwide Contacts www.tyco-fire.com Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description The TYCO Model WS Specific Application Window

More information

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description Technical Services 800-381-9312 +1-401-781-8220 www.tyco-fire.com Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description The TYCO Model ESFR-17 Dry

More information

Submittal Packages Detailed with Items and Reviewers

Submittal Packages Detailed with Items and Reviewers Submittal Packages Detailed with Items and Reviewers Tenochca Upgrades Project # 2351 San Diego State University 5500 Campanile Drive San Diego, CA 92182 Tel: 619-594-3740 Fax: 0050-211000-0 Fire Protection

More information

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description Technical Services: Tel: (800) 38-932 / Fax: (800) 79-5500 Series TY-B 2.8, 5.6, 8.0 K-factor Upright, Pendent, Recessed Pendent Sprinklers Stard Response, Stard Coverage General Description IMPORTANT

More information

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description Worldwide Contacts www.tyco-fire.com Series EC-8 8.0 K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description Pendent Sprinklers are decorative glass bulb sprinklers

More information

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description Page:1 of 5 SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description The Model ZN-RES Residential Flush Pendent

More information

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed. Page 1 of 10 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK504 is a fast response fusible element type sprinkler designed for use in storage areas subject to freezing

More information

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts. Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 6.9 K-factor, Pendent/Recessed Pendent/Concealed, NFPA 13 Optimized Wet Pipe Systems General Description The TYCO

More information

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description Worldwide Contacts www.tyco-fire.com 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description TYCO 5.6K Institutional Pendent and

More information

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems General Description LFII Residential Flush Horizontal Sidewall

More information

SPRINKLERS TABLE OF CONTENTS

SPRINKLERS TABLE OF CONTENTS SPRINKLERS TABLE OF CONTENTS SECTION 21 13 13 WET PIPE SPRINKLER SYSTEMS SECTION 211313 - WET PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,

More information

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage General Description

More information

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design) Page:1 of 5 Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design) General Description The Model HF-RES Residential Flush Horizontal Side-Wall

More information

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 5 1. DESCRIPTION Viking Standard Response Fusible Link Pendent Sprinkler VK008 is a small thermosensitive solder link spray sprinkler available with various finishes and temperature ratings to

More information

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed. Page 1 of 5 1. DESCRIPTION Viking Standard Response Fusible Link Pendent Sprinkler VK008 is a small thermosensitive solder link spray sprinkler available with various finishes and temperature ratings to

More information

SECTION DRY-PIPE SPRINKLER SYSTEMS

SECTION DRY-PIPE SPRINKLER SYSTEMS SECTION 21 1300 S PART 1 -GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION SECTION 21 1301- FIRE-SUPPRESSION SYSTEMS PART 1 - GENERAL 1.1 SUMMARY: A. This Section includes fire-suppression piping and equipment for the following building systems: 1. Wet-pipe, fire-suppression

More information

Model/Sprinkler Identification Numbers

Model/Sprinkler Identification Numbers Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description The Series TY-B, 5.6

More information

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

Model vkfd28b braided flexible sprinkler drops (lpcb approved) Page 1 of 6 1. DESCRIPTION Viking Flexible Sprinkler Drops are a complete assembly intended for installation into commercial suspended ceilings with medium to heavy support tee bars as described in ASTM

More information

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description Worldwide Contacts www.tyco-fire.com Model AV--00 Alarm Valve With and Without Model RC- Retard Chamber European Conformity Valve Trim General Description The TYCO Model AV--00 Alarm Valves DN, DN0, DN0,

More information

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description Worldwide Contacts www.tyco-fire.com Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRL,

More information

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608 Page 1 of 6 TECHNICAL DATA 1. DESCRIPTION The Viking Standard/Quick Response Extended Coverage Light Hazard Extra- Large Orifice (ECLH-ELO/QRECLH-ELO) Pendent Sprinkler VK608 is a thermosensitive spray

More information

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6 Page 1 of 6 1. DESCRIPTION The Viking Micromatic Standard Response Pendent VK004 Sprinkler is a small, thermosensitive, glass-bulb spray sprinkler available in several different finishes and temperature

More information

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University. 15500 - FIRE PROTECTION PART I DESIGN GUIDELINES A. General 1. Vertical fire pumps shall not be used at the University. 2. coupling piping shall be permitted for sprinkler and standpipe systems only. B.

More information

B. Related Sections: The following Sections contain requirements that relate to this Section.

B. Related Sections: The following Sections contain requirements that relate to this Section. SECTION 211313- FIRE-SUPPRESSION PIPING PART1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general prov1s1ons of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

standard response/ quick response extended coverage

standard response/ quick response extended coverage 1. DESCRIPTION Viking Extended Coverage Adjustable Recessed Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry

More information

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description Worldwide Contacts www.tyco-fire.com Series TY-FRL 5.6 and 8.0 K-factor Extended Horizontal Sidewall s Quick & Standard (Light Hazard) General Description The Series TY-FRL, 5.6, and 8.0 K-factor, Extended

More information

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint. (816) 373-4878 U1208-01/FAI29-029 (573) 751-2624 SECTION 2 105 17 - SLEEVES AND SLEEVE SEALS FOR FIRE-SUPPRESSION PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the

More information

Sprinkler Identification Number TY ECLH HSW, 8.0K, 3/4"NPT

Sprinkler Identification Number TY ECLH HSW, 8.0K, 3/4NPT Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage

More information

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant. SECTION 218800 - FIRE PROTECTION 1. GENERAL A. Provisions of Division 1, GENERAL REQUIREMENTS, and Section 230000, MECHANICAL GENERAL CONDITIONS, and Section 230050, SEISMIC PROTECTION are a part of this

More information

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers

More information

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA Page 1 of 6 1. DESCRIPTION Viking Freedom Residential Horizontal Sidewall Sprinkler VK486 is a small, thermosensitive, glass-bulb residential sprinkler available in several different finishes and temperature

More information

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA Page 1 of 5 1. DESCRIPTION The Viking Microfast Quick Response Pendent Sprinkler VK3311 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to

More information

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description Sprinklers (TY2234) are

More information

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description Technical Services 800-381-9312 +1-401-781-8220 www.tyco-fire.com Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

More information

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA Page 1 of 6 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers

More information

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure Sprinkler 41t 1. DESCRIPTION Viking Quick Response Upright and Pendent Sprinklers are small thermosensitive glass bulb spray available with various finishes and temperature ratings to meet design requirements.

More information

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0) Sprinkler 83h 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Ordinary Hazard (ECOH) Upright Sprinkler VK570 and Pendent Sprinkler VK572 are thermosensitive glass bulb spray sprinklers

More information

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description Worldwide Contacts www.tyco-fire.com Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description The TYCO Model ESFR-17 Dry Type Pendent Sprinklers (TY7229)

More information

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA Page 1 of 5 1. DESCRIPTION The Viking VK3021 Quick Response Pendent Sprinkler is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design

More information

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A Worldwide Contacts www.tyco-fire.com FASTFLEX Model YN25, YB25, and YB28 Flexible Hose Europe, Middle East, and Africa Only General Description The TYCO FASTFLEX Flexible Hose is a unique sprinkler drop

More information

quick response Sprinkler 105a October 25, 2010

quick response Sprinkler 105a October 25, 2010 October 25, 2010 Sprinkler 105a 1. DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE June 1, 2007 1. DESCRIPTION Viking Quick Response Fusible Element Pendent Sprinklers VK330, VK332, VK353 and HP Sprinklers VK318 and VK343 are small, thermosensitive, solder link spray sprinklers available

More information

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA Page 1 of 5 1. DESCRIPTION Viking Freedom Residential Concealed Pendent VK494 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the

More information

Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Model V3426 residential sprinkler is designed with optimal flow characteristics for use in residential NFPA 13 systems. The larger 6.9 K-Factor will aid

More information

TECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600

TECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600 1. DESCRIPTION Viking Standard Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry systems and preaction

More information

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA Page 1 of 7 1. DESCRIPTION Viking Standard Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry systems

More information

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN) Worldwide Contacts www.tyco-fire.com Model ESFR-25 25.2 K-factor Pendent Sprinkler Early Suppression, Fast Response General Description TYCO Model ESFR-25 Pendent Sprinklers are Early Suppression, Fast

More information

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed. Sprinkler 121a 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Upright Sprinkler VK520 is a fast response fusible element type sprinkler designed for early fire suppression. With a 14.0 (202

More information

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed. Page 1 of 6 1. DESCRIPTION The Viking Microfast Quick Response Fusible Element Horizontal Sidewall Sprinkler VK334 is a small thermosensitive solder link spray sprinkler available with various finishes

More information