Only for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power Maximum radiation intensity Detection pattern

Size: px
Start display at page:

Download "Only for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power Maximum radiation intensity Detection pattern"

Transcription

1 ISO 9001:2000 / ATEX 0158 II 1 GD IIB T135 C (T4) Broad beam optical fibre QW-..-1GD ATEX certificated for Ex zones 0, 1, 2, 20, 21, 22 Applicable for width deviation measurement, detection of small objects and other applications Applicable with ATEX certificated analog sensors IRD-2A(I) S93 N5 Type QW-1500/2,3-50-U-SE-1GD Type of Ex protection Protection by constructive safety, at EN :2002 Applicable in Ex zones Zones 0, 1, 2 and 20, 21, 22 Permitted sensors Only for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power <= 22.8mW Maximum radiation intensity <= 5mW/mm-2 Detection pattern 50mm Length of the optical fibre 1500mm, other dimensions on request Fixing, sensing head Bore holes for screws M4 Adapter fixing at the sensor Coupling nut M30 Material, adaptor and sensing heads Material, protection covering Flexible stainless steel, V2A Optical transmission ratio, average 50-70%, at 880nm Optic axial angle appr. 65, at 880nm Single fiber diameter 50mm (single bending) Operating temperature range TA 0 C < TA < +120 C ATEX related designations CE 0158 Manufacturer with address Device type: QW-..-1GD II 1 G c T4, II 1 D c IP68 T130 C Certification number: BVS 03 ATEX H 047 X TA: 0 C<TA<120 C, Date of construction: Numeral 4 to 7 of the serial number Emitter unit Receiver unit Mounting prescriptions Ex Protection: The optical fibres series QW-..-1GD are applicable in Ex designed such way, that it has the least possible adverse effect Zones 0, 1, 2 and 20, 21, 22. It is necessary to take into on the environment. It neither emit or contain any damaging or consideration the valid international and national rules and siliconized substances and use a minimum of energy and resources. No longer usable or irreparable units must be disposed regulations. The optical fibre must only be operated with ATEX homologated sensors at DMT 99 ATEX E056/N5. The of in accordance with local waste disposal regulations. local equipotential bonding have to be done by grounding General the fixed ATEX sensor. The maximum allowed optical input When installing and operating with the sensor, it is necessary to power must not be exceeded. Protect the optical fibre against take into consideration the relevant international and other national regulations. damages and frictional heat. If the optical fibre and the sensor are not mounted in the same Ex zone, the zone ATEX 118a, ElexV, TRbF, TRD, UVV, EX-RL(BGR 104), transition point must be secured at EN by using the BetrSichV(ATEX 137), single directive 1999/92/EG, additional shrinkingdown plastic tubing. Other then original : manufacturer, additional optical lenses are not allowed in hazardous locations. - Ex protection: 94/9/EG (ATEX 100a) The optical fibre, type QW together with analog sensor IRD-2A(I) - Machine directive: 98/37/EG S93 N5, gives the possibility the realize a precision line scanning Homologation / Declaration of conformity or width measurement of different objects. Certification No.: BVS 03 ATEX H 047 X The conformity of the devices with the EC standards and Protect the fibre optic adaptor and the sensing heads against directives and the EC-type examination certificate and the observation of the Quality Safety System ISO 9001 with the ATEX pollution. If the fibre optics is contaminated, clean with alcohol. Do not use aggressive solvents. Equipment must only be repaired or module "Production", declares: serviced by the manufacturer. QW50_1GD_e4/JUN.20,2006/HB

2 0158 II 2GD IIB T135 C (T4) ISO 9001:2000 / ATEX Glass Fibre Optics QWS-.../4-..-L(-2GD) Silicone rubber protection sheath QWS-xxxx/4-yy-L-2GD: Applicable in Ex Zones 1, 2, 21, 22 up to TA=+120 C QWS-xxxx/4-yy-L: Applicable in Non-Hazardous Locations up to TA=+200 C Type QWS-xxxx/4-yy-L-2GD QWS-xxxx/4-yy-L xxxx = Length in mm, yy = scanning width Ex Protection: Protection by constructional safety at EN :2002 II 2 GD IIB T135 C (T4) None Applicable in Hazardous Locations, Zones 1, 2, 21, Requirement on connected sensors Limited optical power at DMT 99 ATEX E056 None Maximum optical input power <=35mW Not limited Length, QWS-500/4-yy-L 540mm Length, QWS-1000/4-yy-L 1040mm Active scan area, QWS-xxxx/4-30-L 30 x 0.8mm Active scan area, QWS-xxxx/4-60-L 60 x 0.4mm Active cross-sectional area 24mm 2 Optical aperture appr. 65 Material of coupling ring Yellow brass, nickel plated ATEX Designation of the fibre optics CE 0158 Manufacturer with address Identification: QWS-..-2GD II 2GD IIB T135 C(T4) Tech. File Ref.: AN_EXLWL Production date: Numerals 4 to 7 TA: 0 C < TA < +120 C of the serial number 11 D Dimensions A B C D 7.5 QWS-xxxx/4-30-L: 30x0.8mm QWS-xxxx/4-60-L: 60x0.4mm Tolerances: +-0.1mm B A C mm 12 Ex protection: General regulations for all types of Ex devices: The fibre optics series QWS-...-2GD is only applicable in hazardous location / zones 1, 2, 21, 22. The fibre optics must be operated with ATEX certificated sensors with limited optical output power, at DMT 99 ATEX E056. It is necessary to take into consideration the valid international and national rules and regulations. The maximum rated optical input power must not be exceeded. Other then original manufacturer, additional optical lenses are not allowed in hazardous locations. The fibre optics have to be installed in a manner to avoid tensile stress and frictional heat. If fibre optics and associated sensors are not mounted in the same hazardous location, the change over of the different areas must be realized in accordance with the valid regulations. The optical fibre, type QWS together with an analog sensor IRD, gives the possibility the realize a precision line scanning or width measurement of different objects. The fibre optics series QWS are also designed for the construction of light barriers in hazardous locations and for high ambient temperatures. The fibre optics can be operated with certificated Matrix sensors, with an optical wave length from 500nm to 900nm. The fibre optics must not be buckled or laid with a small radius. Buckled or bad laid fibre optics results to a strong decrease of performance. Avoid performance decreasing and failures caused by wear, by a functional mounting of the fibre optics. The fibre optics are maintenance-free. Protect the fibre optics against M4 pollution. If they are contaminated, clean with alcohol. Do not use aggressive solvents. designed such way, that it has the least possible adverse effect on the environment. It neither emit or contain any damaging or siliconized substances and use a minimum of energy and resources. No longer usable or irreparable units must be disposed of in accordance with local waste disposal regulations. When installing and operating with the sensor, it is necessary to take into consideration the relevant international and other national regulations. ATEX 118a, ElexV, TRbF, TRD, UVV, EX-RL, BetrSichV. - Ex-Protection: 94/9/EG (ATEX 100a) - Machine directive: 98/37/EG - Tech. File Ref.: AN_EXLWL, - RoHS, 2002/95/EG Declaration of Conformity: Declaration of conformity by manufacturer. Tech. File Ref.: AN_EXLWL. directive 94/9/EC Certification No: BVS 03 ATEX ZQS / E118. The conformity of the devices with the EC standards and directives and the observation of the Quality Safety System ISO 9001:2000 with the ATEX module "Production", declares: MAT_QWS_xxxx_4_y_L_2GD_e8/JUL.02,2007/HB

3 0158 II 2GD IIB T135 C (T4) ISO 9001:2000 / ATEX Glass Fibre Optics QWS-.../4-..-T(-2GD) Silicone rubber protection sheath For proximity switch function QWS-xxxx/4-yy-T-2GD: Applicable in Ex Zones 1, 2, 21, 22 up to TA=+120 C QWS-xxxx/4-yy-T: Applicable in Non-Hazardous Locations up to TA=+200 C Type QWS-xxxx/4-yy-T-2GD QWS-xxxx/4-yy-T xxxx = Length in mm, yy = scanning width Ex Protection: Protection by constructional safety at EN :2002 II 2 GD IIB T135 C (T4) None Applicable in Hazardous Locations, Zones 1, 2, 21, Requirement on connected sensors Limited optical power at DMT 99 ATEX E056 None Maximum optical input power <=35mW Not limited Length, QWS-500/4-yy-T 540mm Length, QWS-1000/4-yy-T 1040mm Active scan area, QWS-xxxx/4-30-T 30 x 0.8mm Active scan area, QWS-xxxx/4-60-T 60 x 0.4mm Active cross-sectional area 24mm 2 Optical aperture appr. 65 Material of coupling ring Yellow brass Ms58, nickel plated ATEX Designation of the fibre optics CE 0158 Manufacturer with address Identification: QWS-..-2GD II 2GD IIB T135 C(T4) Tech. File Ref.: AN_EXLWL Production date: Numerals 4 to 7 TA: 0 C < TA < +120 C of the serial number 11 D Dimensions A B C D 7.5 QWS-xxxx/4-30-T: 30x0.8mm QWS-xxxx/4-60-T: 60x0.4mm B A C 12 Ex protection: The fibre optics series QWS-...-2GD is only applicable in hazardous location / zones 1, 2, 21, 22. The fibre optics must be operated with ATEX certificated sensors with limited optical output power, at DMT 99 ATEX E056. It is necessary to take into consideration the valid international and national rules and regulations. The maximum rated optical input power must not be exceeded. Other then original manufacturer, additional optical lenses are not allowed in hazardous locations. The local equipotential bonding have to be done by grounding the fixed ATEX sensor. The fibre optics have to be installed in a manner to avoid tensile stress and frictional heat. If fibre optics and associated sensors are not mounted in the same hazardous location, the change over of the different areas must be realized in accordance with the valid regulations. The optical fibre, type QWS together with a certificated sensor, gives the possibility to realize a scanning or width measurement of different objects. The fibre optics series QWS are also designed as proximity switch function in hazardous locations and for high ambient temperatures. The fibre optics can only be operated with certificated Matrix sensors, with an optical wave length from 500nm to 900nm. The fibre optics must not be buckled or laid with a small radius. Buckled or bad laid fibre optics results to a strong decrease of performance. Avoid performance decreasing and failures caused by wear, by a functional mounting of the fibre optics. The fibre optics are maintenance-free. Protect the fibre optics against M4 pollution. If they are contaminated, clean with alcohol. Do not use aggressive solvents. designed such way, that it has the least possible adverse effect on the environment. It neither emit or contain any damaging or siliconized substances and use a minimum of energy and resources. No longer usable or irreparable units must be disposed of in accordance with local waste disposal regulations. When installing and operating with the sensor, it is necessary to take into consideration the relevant international and other national regulations. ATEX 118a, ElexV, TRbF, TRD, UVV, EX-RL, BetrSichV. - Ex-Protection: 94/9/EG (ATEX 100a) - Machine directive: 98/37/EG - Tech. File Ref.: AN_EXLWL, - RoHS, 2002/95/EG Declaration of Conformity: Declaration of conformity by manufacturer. Tech. File Ref.: AN_EXLWL. directive 94/9/EC Certification No: BVS 03 ATEX ZQS / E118. The conformity of the devices with the EC standards and directives and the observation of the Quality Safety System ISO 9001:2000 with the ATEX module "Production", declares: MAT_QWS_xxxx_4_y_T_2GD_e6/NOV.15,2007/HB

4 ISO 9001:2008 / ATEX Glass Fibre Optics SK-xxxx-4-I-2GD / SKM-xxxx-4-I Silicone rubber protection sheath with stainless steel reinforcement SK-xxxx-4-I-2GD: Applicable in Ex Zones 1, 2, 21, 22 at intrinsically safe sensors AX-SE-5x-P30-GF, Ex ia IIC T6 Gb, up to TA=+120 C II 2GD IIB T135 C (T4) SKM-xxxx-4-I: Applicable in Non-Hazardous Locatio, up to TA=+200 C Type SK-xxxx-4-I-2GD SKM-xxxx-4-I xxxx=length in mm Standard length 200mm, 500mm, 1000mm, 1500mm, 2000mm Ex Protection: EN :2002: Nonelectric devices for applications in Ex zones Yes No Applicable in Ex Zones 1, 2, 21, ATEX designation II 2GD IIB T135 C (T4) -- Requirement on connected sensors AX-SE-5x-P30-GF -- Maximum allowed optical input power <=35mW Not limited Active fibre optic diameter 4mm Active cross-sectional area 12.6mm 2 Optical aperture appr. 70 Certificated accessories - Optical probes, designation: OT-SK (Material: Yellow brass, Ni plated) Options - Other length on request ATEX Designation of the fibre optics CE Manufacturer with address Type marking: SK-..-2GD II 2 GD IIB T135 C(T4) SK.-2GD: Declaration by manufacturer at 94/9/EC Tech. File Ref.: AN-MAT-04-EX-LWL:2004 TA: 0 C < TA < +120 C Production date: Numerals 4 to 7 of the serial number ca M18x With optical probe. Type: OT-SK 10 MAT_SK_xxxx_4_I_2GD_e6/ /HB Ex mounting prescriptions Type SK GD: Only applicable in Ex zones 1, 2, 21, 22. The fibre optics must only be operated with the ATEX certificated, intrinsically safe sensors, type AX-SE-5x-P30-GF, Ex ia IIC T6 Gb, with limited optical output power of 35mW. The local equipotential bonding have to be done by grounding the fixed ATEX sensor. It is necessary to take into consideration the valid international and national rules and regulations (EN ). The maximum rated optical input power must not be exceeded. Other then original manufacturer, additional optical lenses are not allowed in hazardous locations. The fibre optics have to be installed in a manner to avoid tensile stress and frictional heat. If fibre optics and associated sensors are not mounted in the same hazardous location, the change over of the different areas must be realized in accordance with the valid regulations. The fibre optics series SK.. are designed for the construction of light barriers in hazardous locations and for high ambient temperatures. The fibre optics must not be buckled or laid with a small radius. Buckled or bad laid fibre optics results to a strong decrease of performance. Avoid performance decreasing and failures caused by wear, by a functional mounting of the fibre optics. The fibre optics are maintenance-free. Protect the fibre optics against pollution. If they are contaminated, clean with alcohol. Do not use aggressive solvents., disposal designed such way, that it has the least possible adverse effect on the environment. It neither emit or contain any damaging substances and use a minimum of energy and resources. No longer usable or irreparable units must be disposed of in accordance with local waste disposal regulations. When installing and operating with the sensor, it is necessary to take into consideration the relevant international and other national regulations. EN , ATEX 118a, EX-RL, BetrSichV. - Ex-Protection: 94/9/EC (ATEX 100a) - Machine directive: 2006/46/EC - Tech. File Ref: AN-MAT-04-EX-LWL: RoHS: 2002/95/EC EC-Declaration of Conformity: SK-.-2GD: Declaration of conformity by manufacturer at 94/9/EC. Tech File No: AN-MAT-04-EX-LWL:2004 directive 94/9/EC Certification No: BVS 03 ATEX ZQS / E118 The conformity of the devices with the EC standards and directives and the observation of the Quality Safety System ISO 9001:2008 with the ATEX module "Production", declares:

5 II 2GD IIB T135 C (T4) ISO 9001:2008 / ATEX Glass Fibre Optics SK L-2GD / SKM L Silicone rubber protection sheath with stainless steel reinforcement SK-xxxx-4-L-2GD: Applicable in Ex Zones 1, 2, 21, 22 up to TA=+120 C SKM-xxxx-4-L: Applicable in Non-Hazardous Locations up to TA=+200 C Type SK-xxxx-4-L-2GD SKM-xxxx-4-L xxxx=length in mm Standard length 200mm, 500mm, 1000mm, 1500mm, 2000mm Ex Protection: EN :2002: Nonelectric devices for applications in Ex zones Yes No Applicable in Ex Zones 1, 2, 21, ATEX designation II 2GD IIB T135 C (T4) -- Requirement on connected sensors Limited optical power at 35mW -- Maximum allowed optical input power <=35mW Not limited Active fibre optic diameter 4mm Active cross-sectional area 12.6mm 2 Optical aperture appr. 70 Certificated accessories - Optical probes, designation: OT-VA (Material: Yellow brass, Ni plated) Options - Other length on request, - Special type GF: SKM-xxxx-4II ATEX Designation of the fibre optics CE Manufacturer with address Type marking: SK-..-2GD II 2 GD IIB T135 C(T4) SK.-2GD: Declaration by manufacturer at 94/9/EC Tech. File Ref.: AN-MAT-04-EX-LWL:2004 TA: 0 C < TA < +120 C Production date: Numerals 4 to 7 of the serial number ca MAT_SK_xxxx_4_L_2GD_e8/ /HB Ex mounting prescriptions Type SK GD: Only applicable in Ex zones 1, 2, 21, 22. The fibre optics must only be operated with the ATEX certificated sensor (DMT 99 ATEX E056) with limited optical output power of 35mW. The local equipotential bonding have to be done by grounding the fixed ATEX sensor. It is necessary to take into consideration the valid international and national rules and regulations (EN ). The maximum rated optical input power must not be exceeded. Other then original manufacturer, additional optical lenses are not allowed in hazardous locations. The fibre optics have to be installed in a manner to avoid tensile stress and frictional heat. If fibre optics and associated sensors are not mounted in the same hazardous location, the change over of the different areas must be realized in accordance with the valid regulations. The fibre optics series SK.. are designed for the construction of light barriers in hazardous locations and for high ambient temperatures. The fibre optics can be operated with certificated Matrix sensors, with an optical wave length from 500nm to 900nm. The fibre optics must not be buckled or laid with a small radius. Buckled or bad laid fibre optics results to a strong decrease of performance. Avoid performance decreasing and failures caused by wear, by a functional mounting of the fibre optics. The fibre optics are maintenance-free. Protect the fibre optics against pollution. If they are contaminated, clean with alcohol. Do not use aggressive solvents. designed such way, that it has the least possible adverse effect on the environment. It neither emit or contain any damaging or siliconized substances and use a minimum of energy and resources. No longer usable or irreparable units must be disposed of in accordance with local waste disposal regulations. When installing and operating with the sensor, it is necessary to take into consideration the relevant international and other national regulations. EN , ATEX 118a, EX-RL, BetrSichV. - Ex-Protection: 94/9/EC (ATEX 100a) - Machine directive: 2006/46/EC - Tech. File Ref: AN-MAT-04-EX-LWL: RoHS: 2002/95/EC CE Declaration of Conformity: SK-.-2GD: Declaration of conformity by manufacturer at 94/9/EC. Tech File No: AN-MAT-04-EX-LWL:2004 directive 94/9/EC Certification No: BVS 03 ATEX ZQS / E118 The conformity of the devices with the EC standards and directives and the observation of the Quality Safety System ISO 9001:2008 with the ATEX module "Production", declares:

6 ISO 9001:2000 / ATEX Glass Fibre Optics VA-.-5-L-M8x15-1GD / VA-.-5-L-M8x15-2GD / VA-.-5-L-M8x Alloyed special steel protection sheath V2A II 1 GD IIB T135 C (T4) VA-...-1GD: Applicable in Ex Zones 0, 1, 2, 20, 21, 22 or VA-...-2GD: Applicable in Ex Zones 1, 2, 21, 22 II 2 GD IIB T135 C (T4) VA-...: Applicable in Non-Hazardous Locations up to TA=+200 C Type VA L-M8x15-1GD VA L-M8x15-2GD VA L-M8x15 Applicable in Ex Zones Applicable in Ex Zones Not for Haz Locs Standard length VA-xxxx-5-L(-.GD) (xxxx=length in mm, 200, 500, 1000, 1500, 2000 Type of Ex Protection: Protection by constructional safety at EN /-5 Yes Yes No Applicable in Hazardous Locations, Zones 0, 1, 2, 20, 21, 22 1, 2, 21, Category / Grouping II 1GD IIB T135 C (T4) II 2GD IIB T135 C (T4) -- Requirement on connected sensors Limited optical power at DMT 99 ATEX E056/N5 None Maximum optical input power <=123mW <=123mW Not limited Maximum potential radiant intensity <= 5mW/mm 2 <= 5mW/mm 2 Not limited Active fibre optic diameter 4.7mm Active cross-sectional area 17.34mm 2 Optical aperture appr. 65 Special steel, V2A Special steel, V2A Anticorodal 110 Special steel, V2A Special steel, V2A Special steel, V2A Accessories, included 2 x Shrink-down plastic tubing Accessories, included 4 x nuts M8 ATEX Designation of the fibre optics CE 0158 Manufacturer with address Identification: VA-..-1GD II 1 GD IIB T135 C(T4) Certification Number: BVS 03 ATEX H 047 X Identification: VA-..-2GD II 2 GD IIB T135 C(T4) Tech. File Ref.: AN_EXLWL Production date: Numerals 4 to 7 TA: 0 C < TA < +120 C of the serial number M8 Ex protection: General regulations for all types of Ex devices: It is necessary to take into consideration the valid international and national rules and regulations. The equipotential bonding must be executed over the associated sensor, reliable and noncorrosive. The maximum rated optical input power must not be exceeded. Other then original manufacturer, additional optical lenses are not allowed in hazardous locations. The fibre optics have to be installed in a manner to avoid tensile stress and frictional heat. If fibre optics and associated sensors are not mounted in the same hazardous location, the change over of the different areas must be realized in accordance with the valid regulations. With the additional shrink-down plastic tubings (only types VA..-1GD) a required change over can be realized. Series VA GD: Applicable in hazardous location / zones 0, 1, 2, 20, 21, 22. The fibre optics must be operated with ATEX certificated sensors with limited optical output power, at DMT 99 ATEX E056/N5. Series VA GD: Applicable in hazardous location / zones 1, 2, 21, 22. The fibre optics must be operated with ATEX certificated sensors with limited optical output power, at DMT 99 ATEX E056/N5. The fibre optics series VA.. are designed for the construction of light barriers in hazardous locations and for high ambient temperatures. The fibre optics can be operated with certificated Matrix sensors, with an optical wave length from 500nm to 900nm. The fibre optics must not be buckled or laid with a small radius. Buckled or bad laid fibre optics results to a strong decrease of performance. Avoid performance decreasing and failures caused by wear, by a functional mounting of the fibre optics. The fibre optics are maintenance-free. Protect the fibre optics against pollution. If they are contaminated, clean with alcohol. Do not use aggressive solvents. designed such way, that it has the least possible adverse effect on the environment. It neither emit or contain any damaging or siliconized substances and use a minimum of energy and resources. No longer usable or irreparable units must be disposed of in accordance with local waste disposal regulations. When installing and operating with the sensor, it is necessary to take into consideration the relevant international and other national regulations. ATEX 118a, ElexV, TRbF, TRD, UVV, EX-RL, BetrSichV. - Ex-Protection: 94/9/EG (ATEX 100a) - Machine directive: 98/37/EG - Tech. File Ref.: AN_EXLWL Certification / Declaration of Conformity Certification VA-...-1GD: BVS 03 ATEX H 047 X Certification of manufacturer VA-...-2GD: Tech. File Ref.: AN_EXLWL The conformity of the devices with the EC standards and directives and the EC-type examination certificate and the observation of the Quality Safety System ISO 9001 with the ATEX module "Production", declares: MAT_VA_xxxx_5_L_M8x15_1GD/2GD_e2/JUN.16,06/HB

ASSURIX Intrinsically Safe Photoelectronic Sensors

ASSURIX Intrinsically Safe Photoelectronic Sensors ISO 9001:2008 / ATEX ASSURIX Intrinsically Safe Photoelectronic Sensors 3wire construction Operating Manual and Control Drawing No. OMAX01 0158 24VL II 2 G Ex ia IIC T6 Gb Applicable in CL I, CL II, CL

More information

ASSURIX Intrinsically Safe Photoelectronic Sensors 3-wire construction Operating Manual and Control Drawing No. OM-AX-01

ASSURIX Intrinsically Safe Photoelectronic Sensors 3-wire construction Operating Manual and Control Drawing No. OM-AX-01 ISO 9001:2000 / ATEX ASSURIX Intrinsically Safe Photoelectronic Sensors 3wire construction Operating Manual and Control Drawing No. OMAX01 0158 II 2 G EEx ia IIC T6 24VL applicable in Ex Zones 1, 2 / CL

More information

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor Product ID Type # Product # Drawing # DSF 1210.00 SHV Ex-atex (2m) 374Z-05066 110428F1 DSF 1210.00 SHV Ex-atex (5m) 374Z-05176 110428F1 DSF 1210.00 SHV Ex-atex (10m) 374Z-05590 110428F1 DSF 1410.00 SHV

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm

More information

PEPPERL+FUCHS GmbH

PEPPERL+FUCHS GmbH Comfort series 1.5 mm embeddable M8x1 4 25 16 13 LED Switching element function NAMUR NC Rated operating distance s n 1,5 mm Installation embeddable Assured operating distance s a 0... 1,215 mm Reduction

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element

More information

Technical Information OUSAF44

Technical Information OUSAF44 TI00416C/07/EN/13.16 71316935 Products Solutions Services Technical Information Optical sensor combined with the OUA260 flow assembly for the measurement of UV absorption Application The sensor measures

More information

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...

More information

Technical Information OUSAF12

Technical Information OUSAF12 TI00497C/07/EN/02.16 71316923 Products Solutions Services Technical Information OUSAF12 Optical sensor combined with the OUA260 flow assembly for absorbance measurement Application The sensor is used to

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Technical Information OUSAF21

Technical Information OUSAF21 TI00471C/07/EN/02.16 71316927 Products Solutions Services Technical Information Optical sensor for the measurement of low color concentrations Application The sensor is used to measure color concentrations

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm

More information

Technical Information OUSAF22

Technical Information OUSAF22 TI00472C/07/EN/02.16 71316931 Products Solutions Services Technical Information OUSAF22 Optical sensor combined with the OUA260 flow assembly for the measurement of color concentrations Application The

More information

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm 0102 Model Number Features 8 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Technical Information OUSTF10

Technical Information OUSTF10 TI00500C/07/EN/02.16 71316944 Products Solutions Services Technical Information OUSTF10 Optical sensor with the OUA260 flow assembly for the measurement of turbidity and undissolved solids Application

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor DSF xx15.xx xhv Ex-Atex Product ID Type # Product # Drawing # DSF 1215.01 SHV Ex-atex (5m) 304Z-05197 113216 DSF 1415.01 AHV Ex-atex S148 304Z-05256 113351 DSF 1615.01 SHV Ex-atex (5m) 304Z-05196 113214

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 50 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 50 mm Installation non-flush Output polarity NAMUR

More information

OPTIBAR P 1010/2010 C Supplementary instructions

OPTIBAR P 1010/2010 C Supplementary instructions OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions

More information

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION Special Safety Instruction en RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION Contents TankRadar Pro European ATEX Directive Information............................... 2 ATEX marking and Ex Certification

More information

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI200EN 09/2017

More information

Product Information to the manual

Product Information to the manual Product Information to the manual Distributed I/O device ET 200iS, Version 10/2001 Introduction This product information contains fixes and additional information relevant to the user manual Distributed

More information

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI100EN 09/2017

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush

More information

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 4.1 Electrical limit switch... 4

More information

Operating Instructions

Operating Instructions Operating Instructions MSi-JM0100-USB R. STAHL HMI Systems GmbH Adolf-Grimme-Allee 8 D 50829 Köln Operating Instructions Version: 01.00.03 Issue date: 29.06.2017 Disclaimer Disclaimer Publisher and copyright

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation non-flush Assured operating distance s a 0...

More information

Translation of the assembly instructions with operating instructions and technical appendix

Translation of the assembly instructions with operating instructions and technical appendix BA Ex-SBU Switch box type SBU-x(1,2,3)x Translation of the assembly instructions with operating instructions and technical appendix In accordance with EU ATEX Directive 2014/32/EU In accordance with EU

More information

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres Z31.0.XX.6C-11 Temperature Probe for potentially explosive atmospheres (Measuring ranges from -200 to +900 C) Operating Manual GTF 103-Ex 0081 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße

More information

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing

More information

MICROpeL 75 Combustible Gas Sensor Part Number: PM

MICROpeL 75 Combustible Gas Sensor Part Number: PM MICROpeL 75 Combustible Gas Sensor Part Number: PM759-000 Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance Reduced

More information

Installation and Operating Instruction

Installation and Operating Instruction Installation and Operating Instruction Automatic Fire Detectors Series 900 Ex (i) 9893 0.00 GB Technical changes reserved! 0 Installation and Operating Instruction Automatic Fire Detectors Series 900 Ex

More information

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Rosemount 3490 Series 4 20 ma + HART Compatible Controller 00825-0200-4841, Rev AB Rosemount 3490 Series 4 20 ma + HART Compatible Controller Failure to follow safe installation guidelines could result in death or serious injury The Rosemount 3490 Series Control

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

Indoor/outdoor resistance thermometer Model TR60

Indoor/outdoor resistance thermometer Model TR60 Temperature Indoor/outdoor resistance thermometer Model TR60 WIKA data sheet TE 60.60 for further approvals see page 2 Applications Ambient temperature measurement Air-conditioned rooms, cold-storage rooms,

More information

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI500EN 09/2017

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators EC-Type Examination Certificate TÜV99 ATEX 1479X Accessories BT32 BT32XS BT32XAS BT33 BT34 V1-G-N4-5M-PUR Female cordset, M12, 4-pin, NAMUR,

More information

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

4P75 CiTipeL Combustible Gas Sensor Part Number: PM Product Datasheet 4P75 Document Purpose The purpose of this document is to present the performance specification of the 4P75 CiTipeL. This document should be used in conjunction with Operating Principles

More information

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these instructions

More information

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Flow switch.   Operating Manual. English manual page Page 1 of 15 Fax: Operating Manual www.jlso-tec-trade.de Flow switch English manual page 1-15 Page 1 of 15 Flow switch Table of Contents Page 1 Device Description and Intended Use... 19 1.1 Flow switch version VH...X...

More information

FDOOT241-A9-Ex Multisensor fire detector

FDOOT241-A9-Ex Multisensor fire detector FDOOT241-A9-Ex Multisensor fire detector ASAtechnology TM For potentially explosive areas Sinteso Collective Signal processing with ASAtechnology Multiple protocol detector (collective/fdnet-ex) Event-controlled

More information

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL Contents IMPORTANT... 3 General Description... 4 General Operation... 4 Changing Factory Settings... 4 Alarm Type... 4 Check Interval...

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further. ATEX SOLUTIONS In order to apply a single level for health and safety requirements and to overcome barriers of trade within Europe, national regulations for explosion prevention were harmonized in 1975

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000

More information

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS 10.0008 Ex td A20, A20/21, A20/22, A21 IP66 T 0044 37675 Contents 1 Area of applicability 3 2 General information 3 2.1 Zone 20 instruments

More information

Operating Instructions

Operating Instructions Operating Instructions ProVicom MT-65, MT-125 R. STAHL HMI Systems GMBH Im Gewerbegebiet Pesch 14 50767 Köln Version 1.7 Issue: 21.07.2008 R. STAHL HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc

More information

COMPACT FLAME CONTROLLER CFC 2000

COMPACT FLAME CONTROLLER CFC 2000 COMPACT FLAME CONTROLLER CFC 2000 TECHNICAL DESCRIPTION EDITION: TB_CFC2000_EN_REV09_20150408 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring

More information

OilMatic Pro / 230 V AC

OilMatic Pro / 230 V AC Instructions manual OilMatic Pro / 230 V AC Alarm system for oil-water separators OilMatic Pro 22-01-2017 Manufacturer: Bamo 1 Description...3 2 Mounting and start-up...4 3 Wiring...5 4 Startup - tests...7

More information

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation EVL-B Shock-resistant tempered glass - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation costs - Suitable for GAS category IIC LED

More information

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard Persons concerned: Experienced professional electricians as per EU Directive

More information

VERSAFLOW VORTEX Supplementary instructions

VERSAFLOW VORTEX Supplementary instructions VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according

More information

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC PROCESS AUTOMATION Instruction manual Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC With regard to the supply of products, the current issue of the following document is applicable: The General

More information

Alarm system For oil-water separator

Alarm system For oil-water separator INSTRUCTIONS MANUAL Alarm system For oil-water separator Safety precautions Fitting, wiring, initial start-up and maintenance operations must be done by trained technicians. All European and local rules

More information

TSLC 6 UV LED 24v Strips

TSLC 6 UV LED 24v Strips TSLC 6 UV LED 24v Strips ILS-XC06-####-SD111. Product Overview At the heart of each UV 6 product are 6 compact, high quality and reliable TSLC C3535 1-chip UV LED, with a primary 125 degree lens, featuring

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX) COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX) TECHNICAL DESCRIPTION EDITION: TB CFC200-REV3-2015-04-07 IMPORTANT: Please note, that all mounting and wiring as well as all changing or adjustment at the

More information

ANNEX GD-CERT-EX-EN SIT

ANNEX GD-CERT-EX-EN SIT SITEX ATEX Couplings ATEX ANNEX GD-CERT-EX-EN SIT S.p.A. Viale A. Volta, 2-20090 Cusago (MI) - Italy Tel. +39.02891441 Fax +39.0289144291 - info@sitspa.it www.sitspa.com ATEX Annex This Annex is an integral

More information

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS The ATEX Directive consists of two EU Directives, ATEX Directive 2014/34/EU and ATEX Directive 99/92/EC. ATEX Directive 2014/34/EU embodies the European minimum

More information

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series Description Page Introduction to Cable Glands 399 EEXe Series 400-401 Polyamide Cable Glands for Unarmored Cable Increased Safety EEXe Series Ex e Certified Ex I Application Entry Thread Seal A2F, E1FX/E2FX,

More information

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics... 14 Ex SOLENOID / ALARM DRIVER PRepower 5203B Table of contents Warnings... 16 Safety instructions... 17 Declaration of Conformity... 19 How to dismantle SYSTEM 5000... 20 Application... 21 Technical characteristics...

More information

OPTIWAVE X500 Supplementary Instructions

OPTIWAVE X500 Supplementary Instructions OPTIWAVE X500 Supplementary Instructions OPTIWAVE 3500 C OPTIWAVE 6500 C OPTIWAVE 7500 C Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE X500 1 General safety information 4 1.1

More information

COMPACT FLAME CONTROLLER CFC 1000

COMPACT FLAME CONTROLLER CFC 1000 COMPACT FLAME CONTROLLER CFC 1000 TECHNICAL DESCRIPTION EDITION: TB CFC1000- REV.6 2012-03-07 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring

More information

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance Battery Powered Separator Alarm Type 17200 Standalone Unit Installation, Operation & Maintenance Battery Powered Separator Alarm Type 17200 Contents Declaration of Conformity 3 IMPORTANT 3 General Description

More information

Cable Glands DB Series: Drain, Breather Valves and Unions

Cable Glands DB Series: Drain, Breather Valves and Unions DB Series: Drain, Breather Valves and Unions 093498 Bleed Valve 093486 Combination Drain and Breather Compliance Data: ATEX Zone 1 & 2 21 & 22 ATEX II 2 GD Ex e II IP 66 CEC NEC Class 1 Zone 1 NEMA 4X

More information

- SAFETY MANUAL - DAMPERS

- SAFETY MANUAL - DAMPERS EUROPAIR srl Via Po, 160 20032 - Cormano (Mi) P.IVA C.F. 04009650963 Tel. 39 02 66305530 Fax 39 02 66306876 info@europairitalia.it - www.europairitalia.it UNI EN ISO 9001 - SAFETY MANUAL - DAMPERS This

More information

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Status:

More information

SET Installation and Operating Instructions. Level switch for one sensor

SET Installation and Operating Instructions. Level switch for one sensor Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel.: +358 29 006 260 Fax: +358 29 006 1260 7.11.2013 Internet: www.labkotec.fi 1/14 SET-1000 Level switch for one sensor Copyright 2013 Labkotec Oy

More information

INSTALLATION GUIDE Ultrasonic Sensors Series UPR-A Atex

INSTALLATION GUIDE Ultrasonic Sensors Series UPR-A Atex INSTALLATION GUIDE Ultrasonic Sensors Series UPR-A Atex For further information please see the data sheet at www.waycon.biz/products/ultrasonic-sensors/ FIRST STEPS WayCon Positionsmesstechnik GmbH would

More information

XLFE-4/1. Borosilicate glass globe

XLFE-4/1. Borosilicate glass globe XLFE-4/1 Borosilicate glass globe - Zone 1, 2, 21, 22 - Obstruction warnings - LOW INTENSITY LED technology - Lamp lifespan more than 10 years - Complies with ICAO, FAA Painted aluminium body Ex e terminal

More information

4) Intrinsic Safety Certification

4) Intrinsic Safety Certification INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for

More information

OOH740-A9-Ex Multi-sensor fire detector

OOH740-A9-Ex Multi-sensor fire detector OOH740-A9-Ex Multi-sensor fire detector ASAtechnology TM For potentially explosive areas Cerberus PRO Collective Signal processing with ASAtechnology Multiple protocol detector (collective/c-net-ex) Event-controlled

More information

Supplementary Installation and Operating Instructions. Category II2G

Supplementary Installation and Operating Instructions. Category II2G Supplementary Installation and Operating Instructions Flap-type Flow Meter Category II2G 2 Contents 1. General safety directions...3 2. Main safety-relevant characteristics...4 2.1. Category / Zone...4

More information

TRASCO ATEX Couplings

TRASCO ATEX Couplings TRASCO ATEX Couplings ATEX ANNEX GRM-CERT-EX-EN SIT S.p.A. Viale A. Volta, 2-20090 Cusago (MI) - Italy Tel. +39.02891441 Fax +39.0289144291 - info@sitspa.it www.sitspa.it ATEX Annex This Annex is an integral

More information

Universal Tank Alarm Type Installation, Operation & Maintenance

Universal Tank Alarm Type Installation, Operation & Maintenance Universal Tank Alarm Type 14400 Installation, Operation & Maintenance Universal Tank Alarm Type 14400 Contents Declaration of Conformity 3 IMPORTANT 3 General Description 4 General Operation 4 Installation

More information

IRceL CH4 Methane (CH 4

IRceL CH4 Methane (CH 4 Product Datasheet IRceL CH4 Methane Sensor Document Purpose The purpose of this document is to present the performance specification of the IRceL CH4 Methane gas sensor. This document should be used in

More information

OOH740-A9-Ex Multisensor fire detector

OOH740-A9-Ex Multisensor fire detector OOH740-A9-Ex Multisensor fire detector ASAtechnology TM For potentially explosive areas Cerberus PRO Collective Signal processing with ASAtechnology Multiple protocol detector (collective/c-net-ex) Event-controlled

More information

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D Regulated Ex-Heater HEX5-1.08 with internal controller, HEX5-2.08 with external controller II 3 G II 3 D Instruction Manual Version 1.02.00 Dear customer, we have made up this operating manual in such

More information

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance 4P-90 CiTipeL Combustible Gas Sensor Part Number: PM143-000 Performance

More information

Sinus Jevi (Explosion-Proof) Condens Heaters

Sinus Jevi (Explosion-Proof) Condens Heaters Sinus Jevi (Explosion-Proof) Condens Heaters Heating elements for dehumidification of sealed switchboards and control cabinets. Due to temperature limitations on e.g. print and plastic cabinets it is important

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG15E and BExBG10E Flameproof / Increased Safety Xenon Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG15E and BExBG10E beacons are flameproof

More information

AD.3.XG... Atex directive ch. I Page 22 Atex classification ch. I Page 23. Tab.1 Assembly ch. I Page 25

AD.3.XG... Atex directive ch. I Page 22 Atex classification ch. I Page 23. Tab.1 Assembly ch. I Page 25 Atex directive ch. I Page 22 Atex classification ch. I Page 23 Series ch. I Page 24 Technical specifications Ch. I Page 24 Ordering code ch. I Page 24 Tab. Assembly ch. I Page 25 Tab. 2 Voltages ch. I

More information

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0 Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:

More information

14300 MAINS SEPARATOR ALARM MANUAL

14300 MAINS SEPARATOR ALARM MANUAL Conder Environmental Solutions 14300 MAINS SEPARATOR ALARM MANUAL Separator and Alarm provided by: Alarm Installation, Commissioning & Servicing Support Please contact: www.envirotank.com.au www.envirotank.co.nz

More information

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL GS100-ATEX Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL The GS100 beam set is a detection device only, and is designed to be used in

More information

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL GS100-ATEX Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL The GS100 beam set is a detection device only, and is designed to be used in

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

manual addendum DELPHI Ex

manual addendum DELPHI Ex manual addendum DELPHI Ex II 2G Ex eb IIC T4 Gb II 2D Ex tb IIIC T135 C IP65 Db Tamb=-20 +40 C Reference list: Norm (last issue) Title Dir. 2014/34/UE EN 60079-31 EN60079-0 EN60079-7 Equipment and Protective

More information

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The entrepreneurial basis of the R. STAHL Technology Group follows a long tradition. The product range is aimed at specialised

More information

Important Safety Notice

Important Safety Notice Date: 27 th April 2015 Page 1 of 12 SPI Lasers UK Limited Safety Information High Power OEM Fibre Lasers Important Safety Notice This notice outlines important safety related information and must be read

More information

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX SCHMIDT Flow Sensor SS 20.600 Ex - Supplementary instructions for use in explosive atmospheres ATEX SCHMIDT Flow Sensor SS 20.600 Ex ATEX version Table of Contents 1 Important information... 3 2 Storage

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

OilSET Installation and Operating Instructions. Oil Separator Alarm Device Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec

More information

EtherCAT Box Modules (EPxxxx-xxxx)

EtherCAT Box Modules (EPxxxx-xxxx) Notes about operation of EtherCAT Box Modules (EPxxxx-xxxx) in potentially explosive areas (ATEX) Version: 1.1.0 Date: 2011-06-10 Table of Contents Table of Contents 1 Foreword 1 1.1 Notes on the documentation

More information

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector Fibre optic sensor for glass fibre optics VL18LL-M/40a/118/128 with M12, 4-pin metal connector U! Clearly aranged control panel with very light LED display! Flashing power on LED in case of short-circuit!

More information

AND INSTALLATION MANUAL

AND INSTALLATION MANUAL Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel. +358 29 006 260 Fax +358 29 006 1260 Internet: www.labkotec.fi 10.10.2013 SET/DM3AL Level sensor OPERATION AND INSTALLATION MANUAL 1(5) SYMBOLS

More information

Retro-reflective Sensing range: 0mm to 2000mm

Retro-reflective Sensing range: 0mm to 2000mm Retro-reflective : 0 to 2000 2000 2000 SORG2000B45NC1PKS SORG2000B45NC1NKS $ 195 $ 195 Output PNP, Sourcing NPN, Sinking Prograable: Prograable: Switch output (NO/NC) Switch output (NO/NC) Antivalent Antivalent

More information