Sinus Jevi (Explosion-Proof) Condens Heaters

Size: px
Start display at page:

Download "Sinus Jevi (Explosion-Proof) Condens Heaters"

Transcription

1 Sinus Jevi (Explosion-Proof) Condens Heaters Heating elements for dehumidification of sealed switchboards and control cabinets. Due to temperature limitations on e.g. print and plastic cabinets it is important to use a heating element with a large surface and thus a low surface temperature. The condens heater is designed to meet these properties. Liquids Gasses Solids Spaces Resistors Sinus-Jevi Electric Heating B.V. Aambeeld NT Medemblik +31 (0)

2 Anti-Condensation Heaters Heating elements for dehumidification of sealed switchboards and control cabinets. Due to temperature limitations on e.g. print and plastic cabinets it is important to use a heating element with a large surface and thus a low surface temperature. The condens heater is designed to meet these properties. The temperature limit (appr. 65 C) is integrated into the construction and the small physical measurements enables installation in most cabinets and switchboards. The cooling fin profile has an optimal surface in relation to heat loss in circulation airflow. The element is made of black anodized aluminium which optimises heat conduction and emission. INSTALLATION The anti-condensation heater should always be mounted with the cooling ribs in vertical position. The best circulation is achieved by placing the heating element at the lower part of the cabinet. Due to the element s low surface temperature, the position in relation to other components in the cabinet is not critical. Although it is recommended to maintain 5 cm free space on the sides and approx. 3 cm free space to the bottom due to air circulation. CONSTRUCTION The cooling fin profile has an optimal surface in relation to heat loss in circulating airflow. The element is made of black anodized aluminium which optimises heat conduction and emission. The anti-condensation heater is supplied with temperature limit or as a selflimiting construction where a PTC element supplies the profiles with power according to the surrounding temperature. The small cabinet heating element is without thermostat and casted in silicone rubber. The element is supplied with tape for attachment onto the cabinet. Can be used in places where the available space is very limited. the element can be bent with a min. radius of 15 mm. A TECHNICAL SPECIFICATIONS Type Power Voltage Length x Width x Height Proofing Article number Profile OHMSK 9 Watt 230 Volt 100 x 30 x 8 mm IP44 A Silicone OHMSK 70 Watt 230 Volt 142 x 72 x 57 mm IP55 A OHMSK 160 Watt 230 Volt 250 x 116 x 33 mm IP55 A PTC 15 Watt Volt 75 x 72 x 52 mm IP55 A PTC 15 Watt Volt 75 x 72 x 52 mm IP55 A PTC 20 Watt Volt 100 x 116 x 33 mm IP55 A PTC 40 Watt Volt 250 x 116 x 33 mm IP55 A PTC 20 Watt Volt 100 x 116 x 33 mm IP55 A PTC 40 Watt Volt 250 x 116 x 33 mm IP55 A PTC 20 Watt Volt 100 x 116 x 33 mm IP55 A PTC 40 Watt Volt 250 x 116 x 33 mm IP55 A A A

3 Anti-Condensation heater type SEK To prevent condensation inside switch and instrument cabinets; To keep the cabinets frost-free; To maintain a constant temperature inside the cabinet, independent of the weather s influence. The different models can be supplied self-adjusting or with built-in or surfacemounted thermostats. In order to keep switch cabinets free of condensation, the following guidelines are employed: - Switch cabinet for indoor use: Watt per m³ cabinet volume. - Switch cabinet for outdoor use: Watt per m³ cabinet volume - Switch cabinet for outdoor use in extreme circumstances: Watt per m³ cabinet volume. In extraordinary cases, we recommend that you ask for advice. INSTALLATION Mounting depends on the type. Because of inductive radiation, some types of cabinet heaters must be mounted at least 40 mm away from sensitive equipment or wiring. To make full use of the heat-emission from the cabinet heaters, it is important to place the heating element as low as possible in the cabinet. In case of wide cabinets, it is advisable to place more and/or longer elements for optimal heat distribution. In larger cabinets, it is sometimes advisable to install a fan. CONSTRUCTION The connecting voltage is 230 Volt. TECHNICAL SPECIFICATIONS Type Power Voltage Length x Width Material Article number SEK Watt 230 Volt 100 x 40 mm Mica A Anti-Condensation heater type SHZ The cabinet heaters type SHZ are especially designed for application where a high output is required. The heaters are provided with a surface-mounted adjustable room-thermostat, range 5 C - 30 C, and 500 mm long connection lead. The SHZ cabinet heater is also available without thermostat. In that case, the heater has to be controlled by an external control thermostat. Proofing: IP65 (IP30 when thermostat is mounted). TECHNICAL SPECIFICATIONS Type Power Voltage Length x Width Proofing Material Article number SHZ Watt 230 Volt 330 x 165 mm IP30 Galvanised steel A SHZ Watt 230 Volt 580 x 165 mm IP30 Galvanised steel A

4 Anti-Condensation heater type GSM Direct Heaters for non-hazardous (safe area) locations, designed for: anticondensation, freeze protection and All Cameo Heaters are designed around self-limiting heating consumption. Our Cameo Space Heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed. In other situations, if the equipment may not exceed a maximum temperature value, you can add one of our thermostats for non-hazardous areas. Do not cover the fins to guarantee free convection. Voltage AC/DC: Ambient temp. range: other lengths optional, on request appr gr. 164 x 54 x 54 mm (LxWxH) black anodised aluminium. 110/240 Volt -60 C C optional: non braided GSM-1A Appr. 115 C surface temperature* Watt A A GSM-2A Appr. 105 C surface temperature* Watt A A GSM-3A Appr. 90 C surface temperature* Watt A A GSM-4A Appr. 70 C surface temperature* Wat A A High power model GSM-0AHP Appr. 130 C surface temperature* Watt A A Also mounting brackets available for this type Type GSM Anti-Condensation heater type GSMLP Direct Heaters for non-hazardous (safe area) locations, designed for: anticondensation, freeze protection and All Cameo Heaters are designed around self-limiting heating consumption. Our Cameo Space Heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed. In other situations, if the equipment may not exceed a maximum temperature value, you can add one of our thermostats for non-hazardous areas. Do not cover the fins to guarantee free convection. Voltage AC/DC: Ambient temp. range: other lengths optional, on request appr gr. 100 x 54 x 54 mm (LxWxH) black anodised aluminium. 110/240 Volt -60 C C Type GSMLP optional: non braided GSMLP-1A Appr. 115 C surface temperature* Watt A A GSMLP-2A Appr. 105 C surface temperature* Watt A A GSMLP-3A Appr. 90 C surface temperature* Watt A A GSMLP-4A Appr. 70 C surface temperature* Wat A A High power model GSMLP-0AHP Appr. 130 C surface temperature* Watt A A 4

5 Anti-Condensation Direct heater type GCT Direct Heaters for non-hazardous (safe area) locations, designed for: freeze protection, anti-condensation and All Cameo Heaters are designed around self-limiting heating consumption. Our Cameo Direct-Heaters are designed to heat air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed. In other situations, if the equipment may not exceed a maximum temperature value, you can add one of our thermostats for non-hazardous areas. Voltage AC/DC: Ambient temp. range: other lengths optional, on request appr. 600 gr. 88 x 70 x 35 mm (LxWxH) black anodised aluminium. 110/240 Volt -60 C C optional: non braided Type Article number Type GCT Incl. hexagonal spacers GCT-1A T3 Appr. 115 C surface temperature* Watt A A GCT-2A T4 Appr. 105 C surface temperature* Watt A A GCT-3A T4 Appr. 90 C surface temperature* Watt A A GCT-4A T4 Appr. 70 C surface temperature* Watt A A This type is also available in stainless steel Anti-Condensation Direct heater type GLP Direct Heaters for non-hazardous (safe area) locations, designed for: freeze protection, anti-condensation and All Cameo Heaters are designed around self-limiting heating consumption. Our Cameo Direct-Heaters are designed to heat air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed. In other situations, if the equipment may not exceed a maximum temperature value, you can add one of our thermostats for non-hazardous areas. Voltage AC/DC: Ambient temp. range: other lengths optional, on request appr. 600 gr. 78 x 30 x 34 mm (LxWxH) black anodised aluminium. 110/240 Volt -60 C C optional: non braided Type GLP GLP-1A T3 Appr. 115 C surface temperature* Watt A A GLP-2A T4 Appr. 105 C surface temperature* Watt A A GLP-3A T4 Appr. 90 C surface temperature* Watt A A GLP-4A T4 Appr. 70 C surface temperature* Watt A A 5

6 Thermostat type Fix-Therm 96 GTH For non-hazardous areas is the Fix-Therm 96 GTH thermostat very suitable. Often used as maximum thermostat in instrumentation cabinets with space heating, to protect the equipment from overheating, or as a minimum thermostat with space heating to protect from freezing. Article number: A Setpoint: from 10 C up to 130 C Housing: Anodised aluminium housing (stainless steel housing available) Current/Voltage: 6A / 240 VAC Temperature classification: T6 and T4 Cable: 3 x 0.75 mm² silicone braided cable, optional: non braided cable. other lengths optional. 30 x 58 mm (ØxH) appr. 160 gr. Switch: SPST Set point tolerance: +/- 3 C Hysteresis: appr. 2 C Mounting bracket: available (B) RANGE Aluminium: TH-10/5 - going up with 5 C setpoints e.g. 10/5-15/10-20/15 etc. up to 130 C maximum. 6

7 Explosion-Proof Space Heater type SM Space Heaters for hazardous locations, this compact model is designed for: anticondensation, freeze protection and All Smart Heaters are designed around self-limiting heating consumption. Our Smart Space Heaters are designed to heat the air inside an enclosure. The cabinet heater can be controlled by our (ex) room thermostats. Do not cover the fins to guarantee free convection. Ex protection class: Certification: Protection degree: Voltage AC/DC: 110/240 Ambient temp. range: -60 C C appr. 350 gr. 164 x 54 x 54 mm black anodised aluminium II2G Ex d IIC T3 or T4 II2D Ex td A21 IP66 T135 C/200 C KEMA 01ATEX2124X IP66 Power consumption: Watt or Watt optional: non braided cable Type SM SM-1A T3 Appr. 115 C surface temperature* Watt A A SM-2A T4 Appr. 105 C surface temperature* Watt A A SM-3A T4 Appr. 90 C surface temperature* Watt A A SM-4A T4 Appr. 70 C surface temperature* Watt A A High power model SM-0AHP T3 Appr. 130 C surface temperature* Watt A A Explosion-Proof Space Heater type SMLP Space Heaters for hazardous locations, this compact model is designed for: anticondensation, freeze protection and Ex protection class: appr. 350 gr. 100 x 54 x 54 black anodised aluminium II2G Ex d IIC T3 or T4 II2D Ex td A21 IP66 T135 C/200 C Certification: KEMA 01ATEX2124X All Smart Heaters are designed around self-limiting heating consumption. Our Smart Space Heaters are designed to heat the air inside an enclosure. The cabinet heater can be controlled by our (ex) room thermostats. Do not cover the fins to guarantee free convection. Protection degree: Voltage AC/DC: Ambient temp. range: IP66 110/ C C Power consumption: Watt or Watt optional: non braided cable Type SMLP SMLP-1A T3 Appr. 115 C surface temperature* Watt A A SMLP-2A T4 Appr. 105 C surface temperature* Watt A A SMLP-3A T4 Appr. 90 C surface temperature* Watt A A SMLP-4A T4 Appr. 70 C surface temperature* Watt A A High power model SMLP-0AHP T3 Appr. 130 C surface temperature* Watt A A 7

8 Explosion-Proof Space Heater type SP Direct Heaters for hazardous locations, designed for direct mounting onto e.g. manufolds etc. Used for anticondensation, freeze protection and All Smart Heaters are designed around self-limiting heating consumption. Our Cameo Direct Heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed. In other situations, if the equipment may not exceed a maximum temperature value, you can add our Fix-Therm96 thermostat as a maximum temperature protection, in the system When required in other applications, e.g. analyzers, it is normal practice to use our Direct Heaters in combination with our Fix Therm96 thermostats (range from 10 C up to 130 C). Do not cover the fins to guarantee free convection. Type SPA Power consumption: Watt or Watt SP-1A T3 Appr. 115 C surface temperature* Watt A A SP-2A T4 Appr. 105 C surface temperature* Watt A A SP-3A T4 Appr. 90 C surface temperature* Watt A A SP-4A T4 Appr. 70 C surface temperature* Watt A A High power model SP-0AHP T3 Appr. 130 C surface temperature* Watt A A Explosion-Proof Space Heater type LPAF Direct Heaters for hazardous locations, designed for direct mounting onto e.g. manufolds etc. Used for anticondensation, freeze protection and All Smart Heaters are designed around self-limiting heating consumption. Our Cameo Direct Heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed. In other situations, if the equipment may not exceed a maximum temperature value, you can add our Fix-Therm96 thermostat as a maximum temperature protection, in the system When required in other applications, e.g. analyzers, it is normal practice to use our Direct Heaters in combination with our Fix Therm96 thermostats (range from 10 C up to 130 C). Do not cover the fins to guarantee free convection. Power consumption: Watt 8 optional: non braided cable 165 x 164 x 60 mm black anodised aluminium Ex protection class: II2G Ex d IIC T3 or T4 II2D Ex td A21 IP66 T135 C/200 C Certification: KEMA 01ATEX2124X Protection degree: IP66 Voltage AC/DC: 110/240 Ambient temp. range: -60 C C optional: non braided cable 164 x 100 x 60 mm black anodised aluminium Ex protection class: II2G Ex d IIC T3 or T4 II2D Ex td A21 IP66 T135 C/200 C Certification: KEMA 01ATEX2124X Protection degree: IP66 Voltage AC/DC: 110/240 Ambient temp. range: -60 C C Type LPAF LPAF-1A T3 Appr. 115 C surface temperature* Watt A A LPAF-2A T4 Appr. 105 C surface temperature* Watt A A LPAF-3A T4 Appr. 90 C surface temperature* Watt A A LPAF-4A T4 Appr. 70 C surface temperature* Watt A A

9 Explosion-Proof Direct Heater type LP(S) Direct Heaters for hazardous locations, this model is designed for: anticondensation, freeze protection and All Direct Heaters are designed around self-limiting heating consumption. Our Direct Heaters are designed to heat the installed equipment. If properly selected for freeze protection, no thermostat will be needed. Alternative 316 Stainless Steel heaters can be delivered for the Watt range. Also possible is an aluminium body with four holes drilled through, for easy mounting. (or Stainless Steel) Ex protection class: II2G Ex d IIC T3 or T4 II2D Ex td A21 IP66 T135 C/200 C Certification: KEMA 01ATEX2124X Protection degree: IP66 Voltage AC/DC: 110/240 Ambient temp. range: -60 C C Additional Technical data for the High Power model LP-0AHP Power: Watt 88x36x36 mm black anodized aluminium nly All other data: the same as the low power models Power consumption: Watt or Watt optional: non braided cable appr. 350 gr. (Stainless Steel 360 gr.) 78 x 30 x 34 mm black anodised aluminium Type LP(S) LP-1A T3 Appr. 115 C surface temperature* Watt A A LP-2A T4 Appr. 105 C surface temperature* Watt A A LP-3A T4 Appr. 90 C surface temperature* Watt A A LP-4A T4 Appr. 70 C surface temperature* Watt A A High power model LP-0AHP T3 Appr. 130 C surface temperature* Watt A A Type (Stainless steel) Article number Incl. hexagonal spacers LP-1AS T3 Appr. 115 C surface temperature* Watt A A LP-2AS T4 Appr. 105 C surface temperature* Watt A A LP-3AS T4 Appr. 90 C surface temperature* Watt A A LP-4AS T4 Appr. 70 C surface temperature* Watt A A High power model LP-0AHPS T3 Appr. 130 C surface temperature* Watt A A Also mounting brackets available for this type 9

10 Explosion-Proof Direct Heater type CT Direct Heaters for hazardous locations, this model is designed for: anticondensation, freeze protection and All Direct Heaters are designed around self-limiting heating consumption. Our Direct Heaters are designed to heat the installed equipment. If properly selected for freeze protection, no thermostat will be needed. appr. 550 gr. 88 x 70 x 35 mm black anodized aluminium Ex protection class: II2G Ex d IIC T3 or T4 II2D Ex td A21 IP66 T135 C/200 C Certification: KEMA 01ATEX2124X Protection degree: IP66 Voltage AC/DC: 110/240 Ambient temp. range: -60 C C Alternative 316 Stainless Steel heaters can be delivered for the Watt range. Also possible is an aluminium body with four holes drilled through, for easy mounting. Power consumption: Watt optional: non braided cable Type CT CT-1A T3 Appr. 115 C surface temperature* Watt A A CT-2A T4 Appr. 105 C surface temperature* Watt A A CT-3A T4 Appr. 90 C surface temperature* Watt A A CT-4A T4 Appr. 70 C surface temperature* Watt A A Explosion-Proof Direct Heater type CS Direct Heaters for hazardous locations, this model is designed for: anticondensation, freeze protection and All Direct Heaters are designed around self-limiting heating consumption. Our Direct Heaters are designed to heat the installed equipment. If properly selected for freeze protection, no thermostat will be needed. Ex protection class: Certification: Protection degree: Voltage AC/DC: 110/240 Ambient temp. range: -60 C C Stainless Steel II2G Ex d IIC T3 or T4 II2D Ex td A21 IP66 T135 C/200 C KEMA 01ATEX2124X IP66 Power consumption: Watt optional: non braided cable appr. 550 gr. 85 x 65 x 28 mm Type CS CS-1A T3 Appr. 115 C surface temperature* Watt A A CS-2A T4 Appr. 105 C surface temperature* Watt A A CS-3A T4 Appr. 90 C surface temperature* Watt A A CS-4A T4 Appr. 70 C surface temperature* Watt A A This type is also available in a general purpose 10

11 Explosion-Proof Thermostat type Fix Therm96 The Explosion-proof FixTherm96 thermostats are often used as maximum thermostat in instrumentation cabinets with space heating for temperature protection and to protect the equipment from overheating. The housing is made from anodized alumnium or stainless steel type 316 (on request). When required in other applications, e.g. analyzers, it is normal to practice to use our space heaters in combination with these FixTherm96 thermostats (range from 10 C up to 130 C). The FixTherm96 can also be used for cooling purposes e.g. FixTherm TH- 10/5F (N.O. contact) Article number: Housing: Current / Voltage: Cable: A Anodized aluminium or stainless steel 6A/240VAC 3x0.75mm² optional: non braided appr. 160 gr. o.d. 30 mm x 58 mm length Switch: SPST Set-point tolerance: +/- 3 C Hysteresis: appr. 2 C Mounting bracket: available (B) Ambient temp. range: C Ex protection class: II2 G Ex d IIC T6 or T4 II2 D Ex td A21 IP66 T85 C or T 135 C Certificate: KEMA 01ATEX2125X RANGE Aluminium: TH-10/5 - going up with 5 C setpoints e.g. 10/5-15/10-20/15 etc. up to 130 C maximum. Stainless steel bodies: identical range. Explosion-Proof Thermostat type ATH Technical specifications Type : Ex Therm-AT Material casing : polyester Setting range : C Switching power : 1-2: AC 16(2,5)A 230V, 1-4: AC 6,3(2,5)A 230V Max. ambient temp. : 40 C Dimensions : 106 x 200 x 90 mm Protection class : IP65 Article number : A Weight : approx gram Certificate : Ex II 2G Ex de IIC T6 Gb Ex II 2D Ex tb IIIC T130 C Db 11

12 Explosion-proof thermostat type EJB D8525 The explosion-proof room thermostat is suitable for gas group IIB with EN/IEC test certificate. The explosion-proof room thermostat consists of a cast flame proof aluminium casing, fitted with 1 or 2 explosion-proof cable glands for armored cable with an outer diameter of 10.5 to 16 mm and an inner diameter of 7.5 to 11.9 mm. Cable gland M20x1.5 HAWKE type 501/453/O. In the aluminium casing a capillary thermostat is built in, adjustable between 0-40 C. The sensor is mounted on the outside of the casing. Technical specifications Type : 1 phase D8525 Supplied with : 2 brass glands (1 cable gland) Material : aluminium casing Setting range : C Ambient temperature : -25 C C Hysteresis : 1.5 C Switching power : max. 16A at 400 Volts AC Sensor dimensions : 147 x Ø6 mm Protection class : IP66 Article number : A Type : 3 phase D8525 Supplied with : 3 brass glands (2 cable glands) Material : aluminium casing Setting range : C Ambient temperature : -25 C C Hysteresis : 2 C Switching power : max. 3x400 Volts AC to 3x16A Sensor dimensions : 210 x Ø6 mm Protection class : IP66 Article number : A Certficate: ATEX - Ex II 2GD Ex de IIB T6 + H2 T6 Gb - Ex tb IIIC T85 C IP66 EN EN Explosion-proof thermostat type EJB D8640 The explosion-proof room thermostat is suitable for gas group IIC with EN/IEC test certificate. This explosion-proof room thermostat consists of a steel or stainless steel casing. Cable gland M20x1.5 HAWKE type 501/453/O. The sensor is located in a perforated guard. The capillary thermostat is adjustable between 0-40 C. Technical specifications Type : D phase Supplied with : 2 brass cable glands Material : steel casing Setting range : C Ambient temperature : -30 C C Hysteresis : 2 C Switching power : max. 3x400 Volts AC to 3x16A Protection class : IP66 Article number : A Type : D phase Supplied with : 2 brass cable glands Material : stainless steel casing Setting range : C Ambient temperature : -30 C C Hysteresis : 2 C Switching power : max. 3x400 Volts AC to 3x16A Protection class : IP66 Article number : A A Certificate: ATEX - Ex II 2GD Ex d IIC T6 Gb - Ex tb IIIC T110 C Db EN/IEC EN/IEC mm 250 mm 103 mm 112 mm 225 mm 100 mm EJB D8525 EJB D

13 Applications Sinus-Jevi space heaters are suitable for anticondensation, freeze protection and s Different applications can be: - switch boards - control cabinets - tunnel fire systems - heating of (very) small spaces 13

14 Sinus is one of the pioneers in the field of explosion proof heating equipment, today we are still operating at the forefront. We manufacture according to ATEX as well as IECEx and EAC directives. For the production of Ex-proof equipment a PQAN (Product Quality Assurance Notification) is issued by TUV-Nord. Our ISO-9001 and ISO systems are also monitored by this organisation. A E Sinus-Jevi Electric Heating B.V. Aambeeld NT Medemblik +31 (0)

Explosion-proof Immersion Heater Type D-8660

Explosion-proof Immersion Heater Type D-8660 Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to

More information

Finned Tube Air Heaters Type WD/GG (RVS)

Finned Tube Air Heaters Type WD/GG (RVS) Finned Tube Air Heaters Type WD/GG (RVS) Our WD-H finned-tube heaters are designed for industrial use in drying rooms, engine rooms, pumping houses, elevator shafts, as protection from frost, etc. The

More information

Anti Condensation Heaters

Anti Condensation Heaters Anti Condensation Heaters Thermal Management Products & Accessories from SAN successfully used worldwide for control panels and enclosures for traffic control and monitoring systems in the transport industry

More information

Fan Heaters Type VLEx

Fan Heaters Type VLEx Fan Heaters Type VLEx Fan Heater type VLEx has been designed for Explosion Proof industrial applications. Our Fan Heaters are characterized mainly by their quality, both in used materials and design. Liquids

More information

Fan Heaters Type TXI, WBK, WBG, Delta & VLE

Fan Heaters Type TXI, WBK, WBG, Delta & VLE Fan Heaters Type TXI, WBK, WBG, Delta & VLE Sinus Jevi has an extensive program of high quality fan heaters for every application. From cost effective model TXI to high power stationary model VLE, all

More information

Performance Data. curus Component Recognized; File No. E IP 20

Performance Data. curus Component Recognized; File No. E IP 20 TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP 20 CE APPLICATION Protect electrical, mechanical equipment from low temperatures, condensation, and corrosion with

More information

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE 763.576.3200 SPEC-00051 O763.422.2211 THERMAL MANAGEMENT ACCESSORIES ENCLOSURE HEATERS Accessories Enclosure Heaters TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP

More information

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0 Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:

More information

Enclosure Heaters and Fan Heaters

Enclosure Heaters and Fan Heaters Enclosure Heaters and Fan Heaters ISC carries innovative products for heating, cooling, temperature and humidity control of electronic enclosures. Our products are renowned for their reliability, long

More information

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation The Series convection heater, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The is available with either C CSA US or CE/ ATEX approvals.

More information

Technology. Drum H eaters ZIEGLER ENGINEERING. Metal drum heater design

Technology. Drum H eaters ZIEGLER ENGINEERING. Metal drum heater design Technology Metal drum heater design Drum H eaters Isopad offers a range of drum and base heaters that provide a reliable way to reduce viscosity, protect stored product from frost and enable product removal.

More information

CR 027 PTC Fan Heater W

CR 027 PTC Fan Heater W CR 027 PTC Fan Heater 400-650 W Compact fan heater Heating power adjusts to ambient temperature Integrated adjustable thermostat Built-in overheat protection DI rail mountable The semiconductor CR 027

More information

Flameproof Manual Call Points Series MCP

Flameproof Manual Call Points Series MCP > Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied

More information

Stego accessories for cabinets

Stego accessories for cabinets www.klinkmann.com Stego accessories for cabinets page Small semiconductor Heater RC 016 2 Touch-Safe Small Heater CSK 060 3 Semiconductor Heater HG 140 4 Hazardous area Heater CREx 020 5 Touch-Safe Heater

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG15E and BExBG10E Flameproof / Increased Safety Xenon Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG15E and BExBG10E beacons are flameproof

More information

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket

More information

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths Product Description The XB, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The XB is available with either CSA C/US or CE/ATEX approvals.

More information

High bay LED lighting fixture

High bay LED lighting fixture Supporting bracket EWL - Zone 1, 2, 21, 22 - Replacing traditional discharge lamps of up to 750W - Savings in energy, maintenance and installation costs - Instant, brilliant illumination - Suitable for

More information

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts. Ex d CCAC - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66 Stainless steel bolts Polyester coating External earth screw Grub screws for opening lid External earth screw

More information

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation EVL-B Shock-resistant tempered glass - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation costs - Suitable for GAS category IIC LED

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT

More information

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres PRODUCT OVERVIEW Light fittings, boxes & custom built control panels for explosive atmospheres LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones

More information

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOG 2014 2 PERFECT THERMAL MANAGEMENT PRODUCT CATALOG - STEGO, Inc. STEGO, Inc. PRODUCT CATALOG - STEGO, Inc. PERFECT THERMAL MANAGEMENT 3 INNOVATION Thermal

More information

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue Product Catalogue Thermal Management Products & Accessories from STEGO successfully used worldwide for control panels and enclosures for traffic control and monitoring systems in the transport industry

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required) FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries

More information

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white . TECHNICAL DATA LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE LAMP TYPE 220-240V, 50/60Hz T8

More information

Enclosure Heaters. Zone 1, Zone 2 & Safe Area

Enclosure Heaters. Zone 1, Zone 2 & Safe Area Enclosure Heaters Zone 1, Zone 2 & Safe Area CONTACT INFORMATION OFFSHORE SOLUTIONS Subject to change without prior notice TPS2121 REV. D 22.08.2017 Kjetil Tengesdal Sales Director Offshore Solutions Special

More information

Thermal Management Products & Accessories for Enclosures

Thermal Management Products & Accessories for Enclosures Thermal Management Products & Accessories for Enclosures Photo: STEGO International Headquarters in Germany STEGO, Inc. 1395 S. Marietta Parkway Building 800 Marietta, GA 30067 Tel: (770) 984-0858 Fax:

More information

Exp, pressurized systems

Exp, pressurized systems Exp, pressurized systems ATEX approved Principle, requirements and recommendation Exp, explosion protected systems The principle of a pressurized apparatus The entry of a surrounding atmosphere into the

More information

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures HDL-3-EX* Complete and ready to install Heat Detector with Ex-certified Box, Cable gland and wiring

More information

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX) COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX) TECHNICAL DESCRIPTION EDITION: TB CFC200-REV3-2015-04-07 IMPORTANT: Please note, that all mounting and wiring as well as all changing or adjustment at the

More information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified

More information

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS PENTAIR CLEAN AIR SYSTEMS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition

More information

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI200EN 09/2017

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

manual addendum DELPHI Ex

manual addendum DELPHI Ex manual addendum DELPHI Ex II 2G Ex eb IIC T4 Gb II 2D Ex tb IIIC T135 C IP65 Db Tamb=-20 +40 C Reference list: Norm (last issue) Title Dir. 2014/34/UE EN 60079-31 EN60079-0 EN60079-7 Equipment and Protective

More information

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI100EN 09/2017

More information

Flameproof Manual Call Points Series MCP

Flameproof Manual Call Points Series MCP > Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied

More information

Description. Applications

Description. Applications CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW

More information

CF1 ProVector Explosion-Proof Heaters

CF1 ProVector Explosion-Proof Heaters CF1 ProVector Explosion-Proof Heaters The CF1 Series ProVector Explosion-proof convection heater offers the most reliable, dependable and trouble-free service available for heating hazardous locations

More information

Explosion Proof Manual Call Points Series MCP

Explosion Proof Manual Call Points Series MCP > Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied

More information

CX1 ProVector Explosion-Proof Heaters

CX1 ProVector Explosion-Proof Heaters Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy

More information

ELECTRICAL EX EQUIPMENT

ELECTRICAL EX EQUIPMENT ELECTRICAL EX EQUIPMENT in hazardous areas Enclosures Reliable Customized Solutions Leader in Explosion Proof Protections CB Control Panel Configuration - Gas group IIB / Dust group IIIC Ex d enclosures

More information

Manual Power relay SR853

Manual Power relay SR853 Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death

More information

Integrated Solutions Low Voltage Systems

Integrated Solutions Low Voltage Systems Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx

More information

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas About Dialight Dialight (LSE: DIA.L) is leading the energy efficient LED lighting revolution around the world for industrial

More information

Electrical Heat Tracing in Hazardous Areas. innovations in heat tracing

Electrical Heat Tracing in Hazardous Areas. innovations in heat tracing Electrical Heat Tracing in Hazardous Areas innovations in heat tracing Table of Contents Introduction 3 1. Heating Cables Type ELSR-N Self-regulating Heating Cable up to 80 C 4-5 Type ELSR-LS Self-regulating

More information

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition proof assemblies, where,

More information

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations AEU1 Explosion-Proof Electric Air Heater For Hazardous Locations 0518 II 2G, Ex d IIB T4 Gb IP55 (ATEX) Ex d IIB T4 Gb IP55 (IECEx) 1ExdIIBT4 X IP55 (EAC Ex) (Suitable for ATEX/IECEx/EAC Ex Zone 1 & 2)

More information

Documentation. Parallel Heating Cable. Type: ELP

Documentation. Parallel Heating Cable. Type: ELP Documentation Parallel Heating Cable Type: ELP 05.01.2018 K. Folkerts Content 1. Data sheet 2. Installation instructions 3. Declarations of conformity 05.01.2018 K. Folkerts 1 05.01.2018 K. Folkerts Constant

More information

Genie Heated Regulator Installation & Operation Instructions

Genie Heated Regulator Installation & Operation Instructions Genie Heated Regulator Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales, LA 70737

More information

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS STW & STW-T SAFE AREA AIR WARMERS HFT, AFT & SAT TYPE AIR THERMOSTATS Please read these

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance

More information

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these instructions

More information

Temperature Measurement Transmitters for field mounting

Temperature Measurement Transmitters for field mounting Siemens AG 07 Overview Application The SITRANS TF can be used everywhere where temperatures need to be measured under particularly harsh conditions. For that reasons users from all industries have opted

More information

Element: Stainless steel (encapsulated) resistance wire. Fresh-Air-Fan 2 capacities. Standing model IP24

Element: Stainless steel (encapsulated) resistance wire. Fresh-Air-Fan 2 capacities. Standing model IP24 Heaters Electric Dimplex room heaters Sinus Jevi finned tube heaters Eurom heaters Air cleaner Eurom electrical heaters budget series. and professional series with a higher airflow Number Description Number

More information

Temperature Control and Monitoring. innovations in heat tracing

Temperature Control and Monitoring. innovations in heat tracing Temperature Control and Monitoring innovations in heat tracing Table of Contents Overview 4-5 Type Ex-Box REG/DIS Type Ex-Box REG/LED Temperature Controller for Hazardous Areas Temperature Controller for

More information

Ex LED light fittings

Ex LED light fittings About us TEP Ex is a regional leader in manufacturing of explosion-protected electrical equipment. Through continuous development of new products and markets, modernization of technology and investment

More information

ARGENTA ATEX For potentially explosive atmospheres. ARGENTA ATEX Technical Specifications Wall-mounting cabinets. ARGENTA ATEX Certifications

ARGENTA ATEX For potentially explosive atmospheres. ARGENTA ATEX Technical Specifications Wall-mounting cabinets. ARGENTA ATEX Certifications For potentially explosive atmospheres IDE presents its ATEX certified product range, specially intended for potentially explosive atmospheres, where the degree of protection and strength must be maximised.

More information

Hazardous Area Portable Fan Heater The Bulldog

Hazardous Area Portable Fan Heater The Bulldog Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable

More information

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S www.stahl.de > Corrosion resistant omnidirectional high output sounder > Integrated Ex d enclosure > Extreme temperature range > 3 stage alarm with independant tone selection for V DC systems > IP66 IP67

More information

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI500EN 09/2017

More information

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

ARRAN LED LED FLOODLIGHT. Standard Specification. Features ARRAN LED LED FLOODLIGHT The Arran LED floodlight range is low energy with an instant on output and up to 130,000 maintenance free hours. Specifically designed for applications where moisture, dirt or

More information

Technical Databook for Industrial Heat-Tracing Systems 2006/2007

Technical Databook for Industrial Heat-Tracing Systems 2006/2007 R Technical Databook for Industrial Heat-Tracing Systems 2006/2007 www.tycothermal.com Tyco Thermal Controls brings together the knowledge, expertise, products and services of the leading brands in industrial

More information

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights CCA-03EX - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22 Directional LED spotlights Body and lid in coated aluminium LED for proper operation monitoring 127 ED.2018

More information

DTS Light fittings for explosive atmospheres

DTS Light fittings for explosive atmospheres DTS Light fittings for explosive atmospheres For all zones and industrial applications LIGHT FITTINGS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones and industrial applications Tubular glass light

More information

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8310 IR Detection of flammable gases and vapour Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

COMPACT FLAME CONTROLLER CFC 2000

COMPACT FLAME CONTROLLER CFC 2000 COMPACT FLAME CONTROLLER CFC 2000 TECHNICAL DESCRIPTION EDITION: TB_CFC2000_EN_REV09_20150408 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring

More information

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version heating for a better future Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version HEATING GASES HEATING LIQUIDS The CETAL-developed Cast-In Circulation Heater Technology

More information

Illumination unit For sight glass level indicator Model LGI

Illumination unit For sight glass level indicator Model LGI Level Illumination unit For sight glass level indicator Model LGI WIKA data sheet LM 33.02 for further approvals see page 2 Applications Better identification of liquid and gaseous phase Direct indication

More information

Hazardous Area Portable Fan Heater The Bulldog

Hazardous Area Portable Fan Heater The Bulldog Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable

More information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExS110D-SIL Flameproof Sounders For use in Flammable Gas Atmospheres BExS110D-SIL 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm

More information

Dual certification! Air handling units for potentially explosive atmospheres

Dual certification! Air handling units for potentially explosive atmospheres Dual certification! Air handling units for potentially explosive atmospheres X-CUBE Ex A certified safety product The air handling unit with dual ATEX certification ATEX directive 2014/34/EU applies to

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

EXHEAT Industrial Standard Products

EXHEAT Industrial Standard Products Standard Products EXHEAT Industrial Standard Products EXHEAT Industrial offers fast track solutions to the industry s wide and varied requirements for electrical heating systems. All our heaters are manufactured

More information

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications Micro and Mini Zones: 0, 1, 2, 20, 21 and 22 Product Overview Features & Benefits The Micro and Mini es use high-tech light sources to give impressive performance with a compact size, designed for easy

More information

Heating THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

Heating THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES Heating THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES HEATING Anticondensation Heaters Application Enclosure heaters are often necessary to prevent failures or corrosion caused by low temperatures

More information

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder Load Systems International 2666 Boul du Park-Technologique Québec QC G1P 4S6 Canada www.loadsystems.com

More information

Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL

Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL Hazardous Location Heaters Thermostat INSTRUCTION MANUAL Rev. K 2018 nvent P/N 89115890 TABLE OF CONTENTS Warranty and Return Policy...2 Application...3 Control Accuracy...3 Technical Data...3 Design Data...3

More information

Portable ATEX Heater. Defend Against Cold. T: +44 (0)

Portable ATEX Heater. Defend Against Cold. T: +44 (0) Portable ATEX Heater T: +44 (0) 191 490 1547 northernsales@thorneandderrick.co.uk Defend Against Cold www.thorneandderrick.com Portable ATEX Heater... Many Problems......One Solution The Problem Low temperatures

More information

Hazardous Area Portable Fan Heater The Bulldog

Hazardous Area Portable Fan Heater The Bulldog Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable

More information

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 4.1 Electrical limit switch... 4

More information

DB4 Range - SPEAKERS - Up to 25 Watts

DB4 Range - SPEAKERS - Up to 25 Watts DB Range - SPEAKERS - Up to 5 Watts Hazardous Location, Weatherproof Features UL listed for USA and Canada Class I, Div, Groups A, B, C & D. Class I, Zone, AExd IIC T. CSFM approved. ATEX approved. NEMA

More information

Thermal management for your cabinets!

Thermal management for your cabinets! ELECTRIC CABINET HEATERS LIGHTS CONTROLLER ELECTRIC CABINET COOLERS Thermal management Thermal management for your cabinets! MORE THAN 55 YEARS the specialist for individual electric cabinet heaters and

More information

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories Product Catalogue Content Heating Small semiconductor Heater HGK 047 Series 3 Semiconductor Heater HG 040 Series 4 Semiconductor Heater HG 140 Series 5 Semiconductor Heater CS 060 Series 6 Semiconductor

More information

Only for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power Maximum radiation intensity Detection pattern

Only for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power Maximum radiation intensity Detection pattern ISO 9001:2000 / ATEX 0158 II 1 GD IIB T135 C (T4) Broad beam optical fibre QW-..-1GD ATEX certificated for Ex zones 0, 1, 2, 20, 21, 22 Applicable for width deviation measurement, detection of small objects

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D Regulated Ex-Heater HEX5-1.08 with internal controller, HEX5-2.08 with external controller II 3 G II 3 D Instruction Manual Version 1.02.00 Dear customer, we have made up this operating manual in such

More information

SOLUZIONI PER ATMOSFERA ESPLOSIVA

SOLUZIONI PER ATMOSFERA ESPLOSIVA catalogo ATEX 2015 SOLUZIONI PER ATMOSFERA ESPLOSIVA ATEX catalogue book 2016 SOLUTIONS FOR EXPLOSIVE ATMOSPHERES Since 1904 In 1904 PALAZZOLI began its activity in Brescia when electrical energy was first

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 8200 CAT Detection of flammable gases and vapors Dräger Polytron 8200 CAT Detection of flammable gases and vapors The Dräger Polytron 8200 CAT is an advanced explosion proof transmitter for the detection of flammable gases in the lower explosion limit

More information

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 5720 IR Toxic Gas Detection Dräger Polytron 5720 IR Toxic Gas Detection The Dräger Polytron 5720 IR is a cost-effective explosion proof transmitter for the detection of carbon dioxide in volume percentage or ppm It uses a high-performance

More information

Cable Glands DB Series: Drain, Breather Valves and Unions

Cable Glands DB Series: Drain, Breather Valves and Unions DB Series: Drain, Breather Valves and Unions 093498 Bleed Valve 093486 Combination Drain and Breather Compliance Data: ATEX Zone 1 & 2 21 & 22 ATEX II 2 GD Ex e II IP 66 CEC NEC Class 1 Zone 1 NEMA 4X

More information

Product Description. Options. Fan Voltage. Electrical Connections Technical Data - Key Characteristics

Product Description. Options. Fan Voltage. Electrical Connections Technical Data - Key Characteristics Cirrus 25/1 The Cirrus 25/1 range of fan heaters uses PTC ceramic heating technology to provide the user with a product ideally suited to climate control. The heater can be controlled independently to

More information

USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS

USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING OR II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS Comprehensive guide available on our website: www.lelas.fr

More information

HEATING. Anticondensation Heaters

HEATING. Anticondensation Heaters HEATING Anticondensation Heaters Application Enclosure heaters are often necessary to prevent failures or corrosion caused by low temperatures or high humidity inside the enclosure. Such conditions are

More information

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOGUE 2018 2 COMPANY PRODUCT CATALOGUE - STEGO STEGO Catalogue 2018 STEGO - PRODUCT CATALOGUE PERFECT THERMAL MANAGEMENT 3 Global presence in Thermal Management

More information

Type CODE Speed Heating Cooling

Type CODE Speed Heating Cooling CLIMA CANAL HYBRID - Low Temperature radiator - Heating and cooling - Build-in height of 10 > 14.5 cm CLIMA CANAL - Low Temperature radiator - Heating - Build-in height of 8.5 > 13 cm 24V EC MOTOR High

More information