CR 027 PTC Fan Heater W

Size: px
Start display at page:

Download "CR 027 PTC Fan Heater W"

Transcription

1 CR 027 PTC Fan Heater W Compact fan heater Heating power adjusts to ambient temperature Integrated adjustable thermostat Built-in overheat protection DI rail mountable The semiconductor CR 027 fan heater prevents the formation of condensation and ensures an even temperature in enclosures. The integrated thermostat is used to set the desired temperature while the high performance axial fan provides forced air circulation. The CR 027 is also available with a continuously running fan (when powered) (100 mm) 6.5 (165 mm) 5 (128 mm) 4.8 (124 mm) Wiring note: Only connect the and 1 terminals - 2 is not used and Grounding is not required Overheat protection built-in temperature limiter service life 50,000 h at 77 F (25 C) see table below 2-pole terminal AWG 14 max. (2.5 mm²), torque 0.8 m max.. plastic, U 94V-0, light grey Optical indicator thermostat control light Mounting clip for 35 mm DI rail, E Operating / Storage temperature -49 to +158 F (-45 to +70 C) Dimensions 6.5 x 3.94 x 5.0 (165 x 100 x 128 mm) Approvals U File o. E Heating Power / Ambient Temperature (@ 50 Hz) Heating Power / Ambient Temperature (@ 60 Hz) W 550W -40 C -20 C 0 C 20 C 40 C -40 F -4 F 32 F 68 F 104 F Temperature C C -20 C 00 C 20 C C -40 F F -4 F F 32 F F 68 F F F Temperature Part o. Heating capacity 1) (@ 50 Hz) Heating capacity 1) (@ 60 Hz) Operating voltage Max. current (inrush) Air flow, free blowing Thermostat setting range Weight (approx.) W 550 W AC V 11.0 A 20 cfm (35 m³/h) 0 to 60 C 2.0 lbs. (0.9 kg ) W 650 W AC V 13.0 A 26 cfm (45 m³/h) 0 to 60 C 2.4 lbs (1.1 kg) W 550 W AC V 14.0 A 20 cfm (35 m³/h) 32 to 140 F 2.0 lbs. (0.9 kg ) W 650 W AC V 15.0 A 26 cfm (45 m³/h) 32 to 140 F 2.4 lbs (1.1 kg) 1) at 68 F (20 C) ambient temperature

2 30 CR 030 Foot-mount Fan Heater 950 W Compact design Built-in overheat protection Integrated adjustable thermostat or fixed hygrostat Double insulated plastic housing The compact CR 030 high performance fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. This fan heater is available with an integrated thermostat for temperature control or a pre-set hygrostat for humidity control. The CR 030 was designed as a stationary unit for the bottom of the enclosure. For panel or DI rail mount, the CR 130 fan heater is recommended. 4.1 (105 mm) high performance cartridge Overheat protection built-in temperature limiter Heater body extruded aluminum service life 50,000 h at 77 F (25 C) 94 cfm (160 m³/h) 2-pole terminal AWG 14 max. (2.5 mm²) with strain relief, clamping torque 0.8 m max. Mounting M5 screws (not included) horizontal Operating* / Storage temperature -49 to +158 F (-45 to +70 C) Dimensions 3.9 x 5.7 x 6.6 (100 x 145 x 168 mm) Weight approx. 3.1 lbs. (1.4 kg) * Operating temperature of heater with integrated hygrostat: +32 to +140 F (0 to +60 C) 5.7 (145 mm) 5.1 (130 mm) 6.6 (168 mm) M 3.9 (100 mm) Wiring diagram Part o. Heating capacity Operating voltage Setting range Approvals W AC 230 V, 50/60 Hz 0 to 60 C U File o. E234324, VDE W AC 230 V, 50/60 Hz 65 %RH, factory-set U File o. E234324, VDE W AC 230 V, 50/60 Hz none (no integrated controls) U File o. E234324, VDE W AC 120 V, 50/60 Hz 32 to 140 F U File o. E W AC 120 V, 50/60 Hz none (no integrated controls) U File o. E CR030/11-12/US

3 CS 028 Touch-Safe PTC Fan Heater 150 W Quiet operation Heating power adjusts to ambient temperature DI rail or screw mount available The CS 028 fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. The heater is connected using the internal terminal connectors. The surface temperatures on the accessible side surfaces of the housing are minimized as a result of the heater design. The CS 028 s small size make it ideal for use in enclosures where space is at a premium (75 mm) 2.56 (65 mm) 3.54 (90 mm) Max. current (inrush) 6 AC 120 V, 12 AC 230 V Surface temperature max. 122 F (50 C) at housing, 212 F (100 C) at top grill; measured at 68 F (20 C) ambient temperature service life 40,000 h at 104 F (40 C) approx. 8 cfm (13.8 m³/h) 2-pole terminal AWG 14 max. (2.5 mm²), torque 0.8 m max. Mounting screw mount or clip for 35 mm DI rail, E View: back side Screw mount DI clip Weight approx oz. (300 g) Operating / Storage temperature -49 to +158 F (-45 to +70 C) 3.74 (95 mm) 2.95 (75 mm) ote other voltages available upon request 1.26 (32 mm) Thermostat CS 028 Fan Heater C -20 C 0 C 20 C 40 C -40 F -4 F 32 F 68 F 104 F Ambient Temperature Wiring example Part o. Heating capacity 1) Operating voltage Dimensions Mounting Approvals W AC 230 V, 50/60 Hz 2.95 x 2.56 x 3.54 (75 x 65 x 90 mm) DI clip U File o. E234324, VDE W AC 230 V, 50/60 Hz 4.49 x 2.56 x 3.54 (114 x 65 x 90 mm) Screw mount U File o. E234324, VDE W AC 120 V, 50/60 Hz 2.95 x 2.56 x 3.54 (75 x 65 x 90 mm) DI clip U File o. E W AC 120 V, 50/60 Hz 4.49 x 2.56 x 3.54 (114 x 65 x 90 mm) Screw mount U File o. E ) at 68 F (20 C) ambient temperature CS028/11-12/US

4 30 CS 030 Foot-mount PTC Fan Heater 1200 W Compact design Built-in overheat protection Integrated adjustable thermostat (optional) Double insulated plastic housing The compact CS 030 high performance fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. This fan heater is available with an optional integrated thermostat for temperature control. The CS 030 was designed as a stationary unit for the bottom of the enclosure. For panel or DI rail mount, the CS 130 fan heater is recommended. Heating Overheat protection built-in temperature limiter service life 50,000 h at 77 F (25 C) 94 cfm (160 m³/h) 2-pole terminal AWG 14 max. (2.5 mm²) with strain relief, M Mounting clamping torque 0.8 m max. M5 screws (not included) horizontal Wiring diagram Operating / Storage temperature Dimensions -49 to +158 F (-45 to +70 C) 4.7 x 5.7 x 6.6 (120 x 145 x 168 mm) Weight approx. 2.6 lbs. (1.2 kg) 4.1 (105 mm) 5.7 (145 mm) 5.1 (130 mm) 6.6 (168 mm) 4.7 (120 mm) -40 C -20 C 0 C 20 C 40 C -40 F -4 F 32 F 68 F 104 F Ambient Temperature Part o. Heating capacity 1) Operating voltage Max. current (inrush) Setting range Approvals W AC 230 V, 50/60 Hz 13.0 A 0 to 60 C U File o. E234324, VDE W AC 230 V, 50/60 Hz 13.0 A none (no integrated controls) U File o. E234324, VDE W AC 120 V, 50/60 Hz 16.0 A 32 to 140 F U File o. E W AC 120 V, 50/60 Hz 16.0 A none (no integrated controls) U File o. E CS030/11-12/US 1) at 68 F (20 C) ambient temperature

5 CS 028 Touch-Safe PTC Fan Heater 250 & 400 W Quiet operation Heating power adjusts to ambient temperature DI rail or screw mount available The CS 028 fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. The heater is connected using the internal terminal connectors. The surface temperatures on the accessible side surfaces of the housing are minimized as a result of the heater design. The CS 028 s small size make it ideal for use in enclosures where space is at a premium. Screw mount 4.33 (110 mm) 3.54 (90 mm) 3.35 (85 mm) View: back side 4.37 (111 mm) DI clip Surface temperature 250 W: max. 122 F (50 C) except upper protective grill, 400 W: max. 149 F (65 C) except upper protective grill; measured at 68 F (20 C) ambient temperature service life 40,000 h at 104 F (40 C) 32 cfm (54 m³/h) at AC 120 V; 26 cfm (45 m³/h) at AC 230 V 2-pole terminal AWG 14 max. (2.5 mm²) with strain relief, screw torque 0.8 m max. Mounting screw mount or clip for 35 mm DI rail, E Weight approx oz. (500 g) Operating / Storage temperature -49 to +158 F (-45 to +70 C) 1.26 (32 mm) Thermostat CS 028 Fan Heater Wiring example -40 C -20 C 0 C 20 C 40 C 60 C -40 F -4 F 32 F 68 F 104 F 140 F Ambient Temperature Part o. Heating capacity 1) Operating voltage Max. current (inrush) Dimensions Mounting Approvals W AC 230 V, 50/60 Hz 15 A 3.54 x 3.35 x 4.37 (90 x 65 x 111 mm) DI clip U File o. E234324, VDE W AC 230 V, 50/60 Hz 15 A 5.08 x 3.35 x 4.37 (129 x 65 x 111 mm) Screw mount U File o. E234324, VDE W AC 120 V, 50/60 Hz 9 A 3.54 x 3.35 x 4.37 (90 x 65 x 111 mm) DI clip U File o. E W AC 120 V, 50/60 Hz 9 A 5.08 x 3.35 x 4.37 (129 x 65 x 111 mm) Screw mount U File o. E W AC 230 V, 50/60 Hz 9 A 3.54 x 3.35 x 4.37 (90 x 65 x 111 mm) DI clip U File o. E234324, VDE W AC 230 V, 50/60 Hz 9 A 5.08 x 3.35 x 4.37 (129 x 65 x 111 mm) Screw mount U File o. E234324, VDE W AC 120 V, 50/60 Hz 6 A 3.54 x 3.35 x 4.37 (90 x 65 x 111 mm) DI clip U File o. E W AC 120 V, 50/60 Hz 6 A 5.08 x 3.35 x 4.37 (129 x 65 x 111 mm) Screw mount U File o. E ) at 68 F (20 C) ambient temperature CS028/11-12/US

6 1.26 (32 mm) 1.26 (32 mm) HV 031 Fan Heater W Flat design Built-in overheat protection 3-side DI rail mountable Shown: 100W - HV 031 Fan Heater The compact HV 031 high-performance fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. For large OEM use, this fan heater can also be provided without the fan, in which case the OEM/customer must provide a fan which meets the minimum airflow requirements (71.5 mm) Important! Heater must be operated together with a fan. Operating without a fan creates the danger of overheating. 100W/ 150W Heater Mounting hole for DI clip 0.98 (25 mm) 0.87 (22 mm) 0.16 (4.2 mm) 3.15 (80 mm) high performance cartridge Overheat protection built-in temperature limiter Heater body die-cast aluminum, glass bead finish 3-pole terminal AWG 14 max. (2.5 mm²), torque 0.8 m max.. housing Mounting clip for 35 mm DI rail, E horizontal Operating / Storage temperature -49 to +158 F (-45 to +70 C) / I (grounded) / service life 50,000 h at 77 F (25 C) see table below Axial fan connection 2-pole terminal AWG 14 max. (2.5 mm²), terminals 2/2 Approvals U File o. E (all), VDE (230VAC only) Air flow abel Axial fan 2.68 (68 mm) 0.71 (18 mm) HV 031 Fan Heater 200W/ 300W/ 400W Heater Mounting hole for DI clip 0.16 (4.2 mm) 0.98 (25 mm) 0.87 (22 mm) Thermostat 4.13 (104.8 mm) 4.68 (119 mm) Air flow 1 2 abel Axial fan 2.68 (68 mm) 0.71 (18 mm) Part o. - AC 120 V Part o. - AC 230 V Heating capacity Min. airflow (free blowing) Dimensions (as mounted) Weight (approx.) W 20 cfm (35 m³/h) 1.85 x 3.15 x 4.41 (47 x 80 x 112 mm) 1.3 lbs. (600 g) W 20 cfm (35 m³/h) 1.85 x 3.15 x 4.41 (47 x 80 x 112 mm) 1.3 lbs. (600 g) W 63 cfm (108 m³/h) 1.85 x 4.68 x 5.94 (47 x 119 x 151 mm) 2.0 lbs. (900 g) W 63 cfm (108 m³/h) 1.85 x 4.68 x 5.94 (47 x 119 x 151 mm) 2.0 lbs. (900 g) W 63 cfm (108 m³/h) 1.85 x 4.68 x 5.94 (47 x 119 x 151 mm) 2.0 lbs. (900 g) HV031/11-12/US

7 CSF 060 Touch-Safe PTC Heater W ow surface temperature Integrated thermostat Wide voltage range Double insulated protection DI rail mountable The CSF 060 is a touch-safe heater for use in enclosures. The design of the heater utilizes natural convection which results in a circulating current of warm air. The surface temperatures on the accessible side surfaces of the housing are minimized as a result of the heater design. This model with plug-in thermostat does not require additional wiring. The CSF 060 is also available in a version without thermostat (CS 060). Operating voltage* AC/DC V (min. 110 V, max. 265 V) Heating capacity see table Surface temperature < 176 F (80 C), except upper protective grill 4-pole terminal AWG 14 max (2.5 mm²), torque 0.8 m max. Mounting clip for 35 mm DI rail, E Operating / Storage temperature -40 to +158 F (-40 to +70 C) / -49 to +158 F (-45 to +70 C) Approvals VDE *Operating with voltages below AC/DC 140 V reduces heating performance by approx. 10% CSF 060 Heater W 100 W 50 W Part o. Wiring example Heating capacity 1) Max. current (inrush) Air outlet temperature 2) 0-40 C -40 F Switch-off temperature 3) Switch-on temperature 3) Dimensions Weight (approx.) W 2.5 A 187 F (86 C) 59 F (15 C) 41 F (5 C) 5.24 x 2.36 x 3.54 (133 x 60 x 90 mm) 10.8 oz. (305 g) W 2.5 A 187 F (86 C) 77 F (25 C) 59 F (15 C) 5.24 x 2.36 x 3.54 (133 x 60 x 90 mm) 10.8 oz. (305 g) W 4.5 A 248 F (120 C) 59 F (15 C) 41 F (5 C) 5.24 x 2.36 x 3.54 (133 x 60 x 90 mm) 11.2 oz. (320 g) W 4.5 A 248 F (120 C) 77 F (25 C) 59 F (15 C) 5.24 x 2.36 x 3.54 (133 x 60 x 90 mm) 11.2 oz. (320 g) W 8.0 A 293 F (145 C) 59 F (15 C) 41 F (5 C) 6.8 x 2.36 x 3.54 (173 x 60 x 90 mm) 15.9 oz. (450 g) W 8.0 A 293 F (145 C) 77 F (25 C) 59 F (15 C) 6.8 x 2.36 x 3.54 (173 x 60 x 90 mm) 15.9 oz. (450 g) 1) see Heating capacity / Ambient temperature diagram 2) measured 2 (50 mm) above protective grill 3) tolerance of ± 5K -20 C -4 F 0 C 32 F Ambient Temperature 20 C 68 F 40 C 104 F CSF060/11-12/US

8 HG 046 Fan Heater 250 & 400 W Built-in overheat protection ong service life DI rail mountable The compact HG 046 fan heater prevents formation of condensation. The integrated high performance axial fan provides forced air circulation and so guarantees an even temperature in enclosures. The heater is wired using the internal terminal connectors (100 mm) 3.35 (85 mm) Overheat protection Heater body Surface temperature resistance - micanite built-in temperature limiter extruded aluminum, anodized 400 W heater - max. 167 F (75 C) service life 50,000 h at 77 F (25 C) 3.35 (85 mm) AC: 26 cfm (45 m³/h) - 50 Hz; 32 cfm (54 m³/h) - 60 Hz DC: 32 cfm (54 m³/h) 3-pole terminal AWG 16 max. (1.5 mm²) with strain relief, clamping torque 0.8 m max. housing Mounting clip for 35 mm DI rail, E Operating / Storage temperature -49 to +158 F (-45 to +70 C) I (grounded) ote: In the case of DC 24 V and DC 48 V, the fan heater must be switched via a relay. For this application, the SM 010 Electronic Relay (Part o or ) is recommended. Pilot contact e.g. KT 011 Thermostat Heater Fan Heater HG 046 (AC 120 V or AC 230 V) Heater Fan Heater HG 046 (DC 24 V or DC 48 V) SM 010 Electronic relay Pilot contact e.g. KT 011 Thermostat Part o. Heating capacity Operating voltage ength () Weight (approx.) Approvals W AC 230 V, 50/60 Hz 7.2 (182 mm) 2.4 lbs. (1.1 kg) U File o. E234324, VDE W AC 230 V, 50/60 Hz 8.7 (222 mm) 3.1 lbs. (1.4 kg) U File o. E234324, VDE W AC 120 V, 50/60 Hz 7.2 (182 mm) 2.4 lbs. (1.1 kg) U File o. E234324, VDE W AC 120 V, 50/60 Hz 8.7 (222 mm) 3.1 lbs. (1.4 kg) U File o. E234324, VDE W DC 24 V 7.2 (182 mm) 2.4 lbs. (1.1 kg) U File o. E W DC 48 V 7.2 (182 mm) 2.4 lbs. (1.1 kg) U File o. E W DC 48 V 8.7 (222 mm) 3.1 lbs. (1.4 kg) U File o. E HG046/11-12/US

9 30 CR 130 Panel-mount Fan Heater 950 W Compact design Built-in overheat protection Integrated adjustable thermostat or fixed hygrostat Double insulated plastic housing Panel or DI rail mounting The compact CR 130 high performance fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. This fan heater is available with an integrated thermostat for temperature control or a pre-set hygrostat for humidity control. The CR 130 was designed as a stationary unit for panel or DI rail mounting. For foot mounting on the bottom of an enclosure, the CR 030 fan heater is recommended. high performance cartridge Overheat protection built-in temperature limiter Heater body extruded aluminum service life 50,000 h at 77 F (25 C) 94 cfm (160 m³/h) 2-pole terminal AWG 14 max. (2.5 mm²) with strain relief, clamping torque 0.8 m max. Mounting clip for 35 mm DI rail, E or M6 screws (not included) horizontal Operating* / Storage temperature -49 to +158 F (-45 to +70 C) Dimensions 3.9 x 6.3 x 7.2 (99 x 160 x 182 mm) Weight approx. 3.1 lbs. (1.4 kg) * Operating temperature of heater with integrated hygrostat: +32 to +140 F (0 to +60 C) 2.6 (67 mm) 5.6 (142 mm) 3.9 (99 mm) 6.3 (160 mm) 7.2 (182 mm) Wiring diagram M Part o. Heating capacity Operating voltage Setting range Approvals W AC 230 V, 50/60 Hz 0 to 60 C U File o. E234324, VDE W AC 230 V, 50/60 Hz 65 %RH, factory-set U File o. E234324, VDE W AC 230 V, 50/60 Hz none (no integrated controls) U File o. E234324, VDE W AC 120 V, 50/60 Hz 32 to 140 F U File o. E W AC 120 V, 50/60 Hz none (no integrated controls) U File o. E CR130/11-12/US

10 CREx 020 Explosion-proof Heater 50 & 100 W arge convection surface Maintenance free DI rail mountable The CREx 020 convection heaters are used in areas with explosion hazard to maintain minimum operating temperatures to help prevent failure of electronic components caused by condensation and corrosion. Explosion protection according to E CIE (aboratoire Central des Industries Electriques) Conformity certificate 01 ATEX 6073/03, CIE 06 ATEX Q8011, IECEx CI high performance cartridge Heater body aluminum profile, black anodized Si HF - JZ 3 x AWG 18 (0.75 mm²), length 3.3 ft (1 m) PE 4 mm² Mounting clip for 35 mm DI rail, E Operating / Storage temperature -49 to +158 F (-45 to +70 C) I (grounded) IP (118 mm) DI clip can alternatively be mounted to other side 2.7 (69 mm) 5.9 / 7.1 (150 / 180 mm) Type: CREx 050W EEx d IIC T5 AC V / 50W Art. r C.I.E. 98.E 6110 Serial o.: e pas ouvrir sous tension. Attendre 15 min. avant ouverture. icht unter Spannung öffnen. Vor öffnen 15 min. warten. Do not open while energized. Wait 15 min. before opening. France S.A. Part o. Operating voltage Heating capacity Ex protection type Surface temperature ength () Weight (approx.) AC V 50 W d IIC T5 - Ex td A21 IP6x T100 C 212 F (100 C) 5.9 (150 mm) 2.9 lbs. (1.3 kg) AC V 50 W d IIC T5 - Ex td A21 IP6x T100 C 212 F (100 C) 5.9 (150 mm) 2.9 lbs. (1.3 kg) AC V 100 W d IIC T4 - Ex td A21 IP6x T100 C 275 F (135 C) 7.1 (180 mm) 3.3 lbs. (1.5 kg) AC V 100 W d IIC T4 - Ex td A21 IP6x T100 C 275 F (135 C) 7.1 (180 mm) 3.3 lbs. (1.5 kg) CREx020/11-12/US

11 30 CS 130 Panel-mount PTC Fan Heater 1200 W Compact design Built-in overheat protection Integrated adjustable thermostat (optional) Double insulated plastic housing Panel or DI rail mounting The compact CS 130 high performance fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. This fan heater is available with an optional integrated thermostat for temperature control. The CS 130 was designed as a stationary unit for panel or DI rail mounting. For foot mounting on the bottom of an enclosure, the CS 030 fan heater is recommended. Heating Overheat protection built-in temperature limiter service life 50,000 h at 77 F (25 C) 94 cfm (160 m³/h) 2-pole terminal AWG 14 max. (2.5 mm²) with strain relief, M Mounting clamping torque 0.8 m max. clip for 35 mm DI rail, E or M6 screws (not included) horizontal Wiring diagram Operating / Storage temperature Dimensions -49 to +158 F (-45 to +70 C) 4.7 x 6.3 x 7.2 (120 x 160 x 182 mm) Weight approx. 2.6 lbs. (1.2 kg) 5.6 (142 mm) 6.3 (160 mm) 7.2 (182 mm) 2.6 (67 mm) 4.7 (120 mm) -40 C -20 C 0 C 20 C 40 C -40 F -4 F 32 F 68 F 104 F Ambient Temperature Part o. Heating capacity 1) Operating voltage Max. current (inrush) Setting range Approvals W AC 230 V, 50/60 Hz 13.0 A 0 to 60 C U File o. E234324, VDE W AC 230 V, 50/60 Hz 13.0 A none (no integrated controls) U File o. E234324, VDE W AC 120 V, 50/60 Hz 16.0 A 32 to 140 F U File o. E W AC 120 V, 50/60 Hz 16.0 A none (no integrated controls) U File o. E ) at 68 F (20 C) ambient temperature CS130/11-12/US

12 HG 140 PTC Heater W Wide voltage range Heating power adjusts to ambient temperature Cage clamp connectors for quick & easy wiring DI rail mountable These heaters are used in enclosures where damage from condensation must be prevented, or where the temperature must be maintained above a minimum value. The aluminum profile heater body design has a chimney effect to distribute heat evenly. The cage clamp connectors save time and simplify installation. Operating voltage* AC/DC V (min. 110 V, max. 265 V) Heater body extruded aluminum profile, anodized 3 cage clamps for solid wire AWG ( mm²), and stranded wire AWG ( mm²) with wire end ferrule casing Mounting clip for 35 mm DI rail, E Operating / Storage temperature -49 to +158 F (-45 to +70 C) I (grounded) Approvals U File o. E234324, VDE ote other voltages available upon request *Operating with voltages below AC/DC 140 V reduces heating performance by approx. 10%. Part o. Heating capacity 1) Max. current (inrush) ength ( on dim. dwg.) Weight (approx.) W 1.5 A 2.56 (65 mm) 7.6 oz. (215 g) W 3.0 A 2.56 (65 mm) 7.6 oz. (215 g) W 3.5 A 2.56 (65 mm) 7.6 oz. (215 g) W 2.5 A 5.5 (140 mm) 14.1 oz. (400 g) W 4.0 A 5.5 (140 mm) 14.3 oz. (405 g) W 4.5 A 5.5 (140 mm) 14.3 oz. (405 g) W 9.0 A 8.66 (220 mm) 21.3 oz. (600 g) 1) at 68 F (20 C) ambient temperature

13 CS 060 Touch-Safe PTC Heater W ow surface temperature Wide voltage range Double insulated protection DI rail mountable The CS 060 is a touch-safe heater for use in enclosures. The design of the heater utilizes natural convection which results in a circulating current of warm air. The surface temperatures on the accessible side surfaces of the housing are minimized as a result of the heater design. The CS 060 is also available in a version with a plug-in thermostat requiring no additional wiring (CSF 060). Operating voltage* AC/DC V (min. 110 V, max. 265 V) Heating capacity see table Surface temperature < 176 F (80 C), except upper protective grill 4-pole terminal AWG 14 max (2.5 mm²), torque 0.8 m max. Mounting clip for 35 mm DI rail, E Operating / Storage temperature -49 to +158 F (-45 to +70 C) Approvals U File o. E234324, VDE ote other voltages available upon request *Operating with voltages below AC/DC 140 V reduces heating performance by approx. 10%. 200 CS 060 Heater Thermostat CS 060 Heater W 100 W 50 W Wiring examples 0-40 C -40 F -20 C -4 F 0 C 32 F Ambient Temperature 20 C 68 F 40 C 104 F Part o. Heating capacity 1) Max. current (inrush) Air outlet temperature 2) Dimensions Weight (approx.) W 2.5 A 187 F (86 C) 4.3 x 2.36 x 3.54 (110 x 60 x 90 mm) 10.4 oz. (295 g) W 4.5 A 248 F (120 C) 4.3 x 2.36 x 3.54 (110 x 60 x 90 mm) 10.6 oz. (300 g) W 8 A 293 F (145 C) 5.9 x 2.36 x 3.54 (150 x 60 x 90 mm) 15.5 oz. (440 g) 1) see Heating capacity / Ambient temperature diagram 2) measured 2 (50 mm) above protective grill CS060/11-12/US

14 CSK 060 Touch-Safe PTC Heater 10 & 20 W ow surface temperature Wide voltage range Double insulated protection DI rail mountable The CSK 060 is a touch-safe heater for use in enclosures. The design of the heater utilizes natural convection which results in a circulating current of warm air. The surface temperatures on the accessible side surfaces of the housing are minimized as a result of the heater design. Heating capacity see table Surface temperature < 185 F (85 C), except upper protective grill 2-pole terminal AWG 14 max (2.5 mm²), torque 0.8 m max. Mounting clip for 35 mm DI rail, E Operating / storage temperature -49 to +158 F (-45 to +70 C) Approvals U File o. E234324, VDE ote other voltages available upon request Thermostat CSK 060 Heater Wiring example Part o. Heating capacity 1) Operating voltage 2) Max. current (inrush) Dimensions Weight (approx.) W AC/DC V 2.5 A 3.86 x 2.95 x 1.5 (98 x 75 x 38 mm) 6.1 oz. (170 g) W AC/DC V 1.0 A 3.86 x 2.95 x 1.5 (98 x 75 x 38 mm) 5.0 oz. (140 g) W AC/DC V 8 A 3.86 x 2.95 x 1.5 (98 x 75 x 38 mm) 5.0 oz. (140 g) 1) at 68 F (20 C) ambient temperature 2) operating high voltage heaters below AC/DC 140 V reduces heating performance by approx. 10% (min. 110 V, max 265 V). CSK060/11-12/US

Enclosure Heaters and Fan Heaters

Enclosure Heaters and Fan Heaters Enclosure Heaters and Fan Heaters ISC carries innovative products for heating, cooling, temperature and humidity control of electronic enclosures. Our products are renowned for their reliability, long

More information

Thermal Management Products & Accessories for Enclosures

Thermal Management Products & Accessories for Enclosures Thermal Management Products & Accessories for Enclosures Photo: STEGO International Headquarters in Germany STEGO, Inc. 1395 S. Marietta Parkway Building 800 Marietta, GA 30067 Tel: (770) 984-0858 Fax:

More information

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOG 2014 2 PERFECT THERMAL MANAGEMENT PRODUCT CATALOG - STEGO, Inc. STEGO, Inc. PRODUCT CATALOG - STEGO, Inc. PERFECT THERMAL MANAGEMENT 3 INNOVATION Thermal

More information

Stego accessories for cabinets

Stego accessories for cabinets www.klinkmann.com Stego accessories for cabinets page Small semiconductor Heater RC 016 2 Touch-Safe Small Heater CSK 060 3 Semiconductor Heater HG 140 4 Hazardous area Heater CREx 020 5 Touch-Safe Heater

More information

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue Product Catalogue Thermal Management Products & Accessories from STEGO successfully used worldwide for control panels and enclosures for traffic control and monitoring systems in the transport industry

More information

Anti Condensation Heaters

Anti Condensation Heaters Anti Condensation Heaters Thermal Management Products & Accessories from SAN successfully used worldwide for control panels and enclosures for traffic control and monitoring systems in the transport industry

More information

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOGUE 2018 2 COMPANY PRODUCT CATALOGUE - STEGO STEGO Catalogue 2018 STEGO - PRODUCT CATALOGUE PERFECT THERMAL MANAGEMENT 3 Global presence in Thermal Management

More information

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOGUE 2018 STEGO Catalogue 2018 Global presence in Thermal Management This catalogue contains the full range of STEGO products for protection of electronic

More information

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories Product Catalogue Content Heating Small semiconductor Heater HGK 047 Series 3 Semiconductor Heater HG 040 Series 4 Semiconductor Heater HG 140 Series 5 Semiconductor Heater CS 060 Series 6 Semiconductor

More information

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOGUE 2018 STEGO Catalogue 2018 Global presence in Thermal Management This catalogue contains the full range of STEGO products for protection of electronic

More information

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE 763.576.3200 SPEC-00051 O763.422.2211 THERMAL MANAGEMENT ACCESSORIES ENCLOSURE HEATERS Accessories Enclosure Heaters TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP

More information

Application. Specifications. Finish

Application. Specifications. Finish Spec-00051 I( McLean Electronics Cooling Thermal Accessories McLean Electronics Cooling: Thermal Accessories Touch-Safe Heaters Industry Standards curus Component Recognized; File No. E150057 IP 20 CE

More information

TOUCH-SAFE HEATERS INDUSTRY STANDARDS

TOUCH-SAFE HEATERS INDUSTRY STANDARDS 763.576.3200 SPEC-00051 L763.422.2211 ACCESSORIES ENCLOSURE HEATERS ACCESSORIES ENCLOSURE HEATERS TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP 20 CE APPLICATION

More information

Performance Data. curus Component Recognized; File No. E IP 20

Performance Data. curus Component Recognized; File No. E IP 20 TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP 20 CE APPLICATION Protect electrical, mechanical equipment from low temperatures, condensation, and corrosion with

More information

Enclosure Cooling, Venting, Heating & Purging Solutions. Celebrating 20 Years of Excellence

Enclosure Cooling, Venting, Heating & Purging Solutions. Celebrating 20 Years of Excellence Enclosure Cooling, Venting, Heating & Purging Solutions Celebrating 20 Years of Excellence Enclosure Climate Control Table of Contents Closed Loop Air Conditioners Pgs 3-18 Thermoelectric Cooling Pgs 32-35

More information

ClimaSys Resistance heaters Selection guide

ClimaSys Resistance heaters Selection guide Selection guide Insulated resistance heaters Power W Voltage Type of connection Terminal block Cable 87504 10 12-36 DC X 87501 10 110-250 AC X 87512 21 12-36 DC X 87502 21 110-250 AC X 87518 55 12-36 DC

More information

Life insurance for your electronics

Life insurance for your electronics ELECTRO-TECHNOLOG FOR INDUSTR Life insurance for your electronics The formation of condensation is one of the biggest dangers for electrical enclosures. As long as they are working under load, their own

More information

Heating THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

Heating THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES Heating THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES HEATING Anticondensation Heaters Application Enclosure heaters are often necessary to prevent failures or corrosion caused by low temperatures

More information

HEATING. Anticondensation Heaters

HEATING. Anticondensation Heaters HEATING Anticondensation Heaters Application Enclosure heaters are often necessary to prevent failures or corrosion caused by low temperatures or high humidity inside the enclosure. Such conditions are

More information

Thermal control. Overview. Adjustable thermostats. Double-adjustable thermostat. Different installation methods. The new quick-fixing systems:

Thermal control. Overview. Adjustable thermostats. Double-adjustable thermostat. Different installation methods. The new quick-fixing systems: Overview Adjustable thermostats O (blue button) with normally open contact to control the starting of a fan when the temperature exceeds the displayed maximum value. C (red button) with normally closed

More information

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection 7 0 Selection guide TO CONTROL THE TEMPERATURE Respects the entered value Compact fixed thermostats Preset factory temperature: NA (blue button):, 0, ºC for the resistance heater. (red button):, 0, ºC

More information

Sinus Jevi (Explosion-Proof) Condens Heaters

Sinus Jevi (Explosion-Proof) Condens Heaters Sinus Jevi (Explosion-Proof) Condens Heaters Heating elements for dehumidification of sealed switchboards and control cabinets. Due to temperature limitations on e.g. print and plastic cabinets it is important

More information

MDA Series. DC Axial Flow Fans with Low-Speed Alarm. $$ The Low-Speed Alarm: "Features

MDA Series. DC Axial Flow Fans with Low-Speed Alarm. $$ The Low-Speed Alarm: Features DC Axial Flow Fans with Low-Speed Alarm MDA Series This series features a built-in alarm circuit that the host controller can recognize if the fan speed drops. This is important for noticing quick drops

More information

POWERFUL. THERMAL MANAGEMENT.

POWERFUL. THERMAL MANAGEMENT. EINFACH INNOVATIV. SICHER BESSER. POWERFUL. THERMAL MANAGEMENT. Thermal Management solutions from STEGO protect sensitive electronic components worldwide against heat, cold and humidity. Take a look at

More information

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths Product Description The XB, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The XB is available with either CSA C/US or CE/ATEX approvals.

More information

Cooling unit Mechanical control

Cooling unit Mechanical control ClimaSys CU Cooling unit Mechanical control Top-mounting models, ref. NSYCU760W2VR- NSYCU10W2VR- NSYCU1460W2VR J 26 A B 8 K 2 0 C D E H F G Cut-out template for top mounting without intermediate frame.

More information

Power. Average noise level (DIN EN ISO 4871)

Power. Average noise level (DIN EN ISO 4871) 21m 3 /h to 102m 3 /h Very low noise Minimal depth in Functional design Time-saving installation Filter fans are used to provide an optimum climate in s. The interior temperature of an can be reduced by

More information

electronics Protection

electronics Protection Climate control electronics PROTECTION 10/2017 PRODUcT catalog WWW.SCHROFF.PENTAIR.co.uk Main Catalogue Content Cabinets...... 1 Climate control Overview Wall mounted cases......... 2 Accessories for cabinets

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation The Series convection heater, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The is available with either C CSA US or CE/ ATEX approvals.

More information

ACS-30-EU-EMDR- 10-MOD

ACS-30-EU-EMDR- 10-MOD ACS-30-EU-EMDR- 10-MOD MULTI-APPLICATION HEAT TRACING CONTROL AND MONITORING IN COMMERCIAL AND RESIDENTIAL BUILDINGS ROOF & GUTTER DE-ICING SENSOR MODULE TECHNICAL INFORMATION DESCRIPTION The nvent RAYCHEM

More information

Technical Specification VFD

Technical Specification VFD Technical Specification - 3-6 VFD Pilot valve enclosures suitable for use in hazardous certified environments. These enclosures are designed and tested to contain both flame and the ignition of dust and

More information

Product Description. Options. Fan Voltage. Electrical Connections Technical Data - Key Characteristics

Product Description. Options. Fan Voltage. Electrical Connections Technical Data - Key Characteristics Cirrus 25/1 The Cirrus 25/1 range of fan heaters uses PTC ceramic heating technology to provide the user with a product ideally suited to climate control. The heater can be controlled independently to

More information

Manual Power relay SR853

Manual Power relay SR853 Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death

More information

Genie Heated Regulator Installation & Operation Instructions

Genie Heated Regulator Installation & Operation Instructions Genie Heated Regulator Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales, LA 70737

More information

CF1 ProVector Explosion-Proof Heaters

CF1 ProVector Explosion-Proof Heaters CF1 ProVector Explosion-Proof Heaters The CF1 Series ProVector Explosion-proof convection heater offers the most reliable, dependable and trouble-free service available for heating hazardous locations

More information

Manual for QX0201 Push Button

Manual for QX0201 Push Button Manual for QX0201 Push Button Purpose of this Instruction Working in hazardous areas, the safety of personnel and plant depends on complying with all relevant safety regulations. Assembly and maintenance

More information

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional

More information

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni OEM Pressure Sub-Mini-Hermet and Omni Factory Set Sub-Mini-Hermet The Sub-Mini Hermet has the ability to be externally adjusted without disconnecting electrical service or tamperproof. These field mounted

More information

Long Life AC Axial Flow Fans MRE Series

Long Life AC Axial Flow Fans MRE Series Long Life AC Axial Flow Fans MRE Series The MRE Series long-life fans have an expected life of 1, hours and are available with a low speed alarm. All MRE Series fans include all components for easy installation.

More information

Dräger Polytron 7000 Fixed gas detector

Dräger Polytron 7000 Fixed gas detector DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Polytron 7000 Fixed gas detector ST-3751-2003 The Dräger Polytron 7000 is a gas detector that can satisfy all toxic and

More information

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE TRACENET TM GENESIS APPLICATION OVERVIEW Control and monitoring systems can play an essential role in heat tracing applications which

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information INSTRUCTION MANUAL D1xB2XH2 Xenon Beacon For use in Hazardous Locations 2) Rating & Marking Information 2.1 Public Mode Fire Alarm Ratings The D1xB2XH2 is certified for use as public mode visual alarm

More information

Gas cylinder scale Model GCS-1

Gas cylinder scale Model GCS-1 Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in

More information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information INSTRUCTION MANUAL D1xB2XH1 Xenon Beacon For use in Hazardous Locations 2) Rating & Marking Information 2.1 Public Mode Fire Alarm Ratings The D1xB2XH1 is certified for use as public mode visual alarm

More information

Fan Heaters Type TXI, WBK, WBG, Delta & VLE

Fan Heaters Type TXI, WBK, WBG, Delta & VLE Fan Heaters Type TXI, WBK, WBG, Delta & VLE Sinus Jevi has an extensive program of high quality fan heaters for every application. From cost effective model TXI to high power stationary model VLE, all

More information

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS Engineering Guideline pac-carriers Type 9195 for Yokogawa ProSafe-RS 2 Engineering Guideline / Yokogawa ProSafe-RS 06.06.2017 Integrated solutions for Yokogawa R. STAHL offers a wide range of customized

More information

Ordering Key. Dielectric strength

Ordering Key. Dielectric strength Controllers AC Semiconductor Controller Type Soft starting and stopping of 3-phase squirrel cage motors Low inrush and reduced vibration during starting Integrated bypassing of semiconductors Rated operational

More information

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI200EN 09/2017

More information

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 8200 CAT Detection of flammable gases and vapors Dräger Polytron 8200 CAT Detection of flammable gases and vapors The Dräger Polytron 8200 CAT is an advanced explosion proof transmitter for the detection of flammable gases in the lower explosion limit

More information

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8310 IR Detection of flammable gases and vapour Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Anti-condensation and climate control

Anti-condensation and climate control Anti-condensation and climate control The new anti-condensation fan heater EH-V series with PTC Engineering Costruzioni Elettromeccaniche P. Torresan http://www.torresansrl.it/ Anticondensation Fan Heater

More information

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING

More information

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE Klimaire 16 SEER CENTRAL DUCTED Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units 10 YEAR LIMITED GUARANTEE R410A R E F R I G E R A N T CSM Condensing Units Features Condensing

More information

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS PENTAIR CLEAN AIR SYSTEMS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition

More information

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI100EN 09/2017

More information

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM APPLICATION OVERVIEW Control and monitoring systems play an essential role in heat tracing applications which range from freeze protecting water lines to

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT

More information

CX1 ProVector Explosion-Proof Heaters

CX1 ProVector Explosion-Proof Heaters Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy

More information

3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure

3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure 3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure Diecast aluminium enclosure with explosion proof (Ex-e) and flame proof (Ex-d) protection suitable for use in hazardous areas,

More information

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM APPLICATION OVERVIEW Control and monitoring systems play an essential role in heat tracing applications which range from freeze protecting water lines to

More information

standards: standards:

standards: standards: INSTRUCTION MANUAL D2xB1LD2 LED Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD

More information

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) INDEX UNIVERSAL ELECTRONIC CONTACTOR UPGRADE SURESWITCH 79 Description Model(s) Page(s) SureSwitch... 49P11-843... 79 CONTACTORS 80 82 Description Model(s) Page(s) 1 Pole... 94-388 Thru 94-395... 80 2

More information

Positive Temperature Coefficient (PTC2) Heater Manual

Positive Temperature Coefficient (PTC2) Heater Manual 2ND GENERATION Positive Temperature Coefficient (PTC2) Heater Manual PTC2-MANUAL 1.5 Read and understand this manual prior to operating or servicing the products. PTC2 Heater Systems are manufactured and

More information

HIGH LUMINOUS EFFICIENCY

HIGH LUMINOUS EFFICIENCY Warehouses, factories, and other industrial facilities have always relied on high bay lighting to provide bright light to large spaces. Now, ASD offers an all-in-one solution to these lighting applications.

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000

More information

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE / 3 GM20 Digital Ground Continuity Relay For AC Systems Technical Bulletin NAE03230 / 0.20 GM20 Ground continuity monitor For AC systems Description The GM20 monitors the loop resistance of ground conductors

More information

Operating Instructions

Operating Instructions Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect

More information

Operating Manual MS220KA and MSR220KA

Operating Manual MS220KA and MSR220KA Temperature Relays and MINIKA, Mains Monitoring, Digital Panel meters MINIPAN, Switching Relays and Controls Operating Manual MS220KA and MSR220KA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße

More information

VIII. Heaters Mobile Climate Control 121 MCC Reference Manual 2014

VIII. Heaters Mobile Climate Control 121 MCC Reference Manual 2014 VIII. Heaters Mobile Climate Control 11 MCC Reference Manual 014 VIII.1. Whispers PN: 89-0 Heater Whisper UW-9 Very compact heater Having the same profile as the UC-9 convector, MCC heater whisper UW-9

More information

PROTECT SRB 200EXi-1A

PROTECT SRB 200EXi-1A 2 Installation up to zone 1/21 J S L1 0V X1 X3 S11 S12 S21 S22 Installation up to zone 2 A1 F1 F2 U B U EXi U i 0V S12 S22 X1 X3 K1 Logic K2 K1 K2 13 23 U EXi SRB 200EXi U B -1A U i K1 K2 PA PA A1 A2 13

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

SIVACON sicube 8MF system cubicles 16/2 Introduction 16/3 8MF system cubicles 16/4 Preconfigured cubicles

SIVACON sicube 8MF system cubicles 16/2 Introduction 16/3 8MF system cubicles 16/4 Preconfigured cubicles System Cubicles, System Lighting and System Air-Conditioning SIVACON sicube 8MF system cubicles /2 Introduction /3 8MF system cubicles /4 Preconfigured cubicles SIVACON 8MF/8MR system lighting /6 Compact/slimline

More information

Explanations of Applications in Hazardous Areas

Explanations of Applications in Hazardous Areas facts & DATA Explanations of Applications in Hazardous Areas Technical information The information regarding cross sectional area and connection types pertains to unprepared wires without ferrules! Ferrules

More information

Enclosure Heaters. Zone 1, Zone 2 & Safe Area

Enclosure Heaters. Zone 1, Zone 2 & Safe Area Enclosure Heaters Zone 1, Zone 2 & Safe Area CONTACT INFORMATION OFFSHORE SOLUTIONS Subject to change without prior notice TPS2121 REV. D 22.08.2017 Kjetil Tengesdal Sales Director Offshore Solutions Special

More information

Thermal management for your cabinets!

Thermal management for your cabinets! ELECTRIC CABINET HEATERS LIGHTS CONTROLLER ELECTRIC CABINET COOLERS Thermal management Thermal management for your cabinets! MORE THAN 55 YEARS the specialist for individual electric cabinet heaters and

More information

Description. Applications

Description. Applications CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW

More information

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O Features Assembly System integration kit for Advanced Diagnostics PCS integration via Diagnostic Manager or device DTM Simple automatic

More information

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI500EN 09/2017

More information

THERMASREG TR 040 THERMASREG TR 060

THERMASREG TR 040 THERMASREG TR 060 THERMASREG TR 040 THERMASREG Temperature controllers, one-step, Mechanical temperature controllers wet room temperature controllers THERMASREG TR 040 with switching output and stainless steel capillary

More information

Accessory Products

Accessory Products Thermostat Designed to provide air temperature control and monitoring in cabinets. Thermostat NC (Normally Closed) for the control of heaters and heater fans. Thermostat NO (Normally Open) for the control

More information

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations synchronization requirements of UL1971 & UL1638 / CAN/ULCS526. 2.2 NEC & CEC Class / Division Ratings for US / Canada

More information

CR Series Command Relays

CR Series Command Relays CR Series Command Relays FEATURES INSTALLATION INSTRUCTIONS Patented 35mm Din-rail mounting flange (US Patent 7,416,421) SPDT Form 1C Relay contacts Pilot duty rated LED status indication Stackable for

More information

DTA. Motor thermistor relay. Benefits. Description

DTA. Motor thermistor relay. Benefits. Description DTA Motor thermistor relay Description DTA71 and are precise Motor thermistor monitoring relays. They can monitor up to 6 motor temperatures through the motor internal temperature. PTCs are connected in

More information

SELECTION GUIDE. Industrial Thermoregulation. Products for panels and enclosures

SELECTION GUIDE. Industrial Thermoregulation. Products for panels and enclosures SELECTION GUIDE Industrial Thermoregulation Products for panels and enclosures 7T Series - Thermo-Hygrostat and Thermostats 7F Series - Filter Fans 7H Series - Panel Heaters Perfect climate inside panels

More information

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor

More information

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition proof assemblies, where,

More information

OPTA-PERIPH 8 Av. de Bretteville Neuilly - France 33(0) Fax : 33(0) Document: IM By PB Date: 18/11/2005

OPTA-PERIPH 8 Av. de Bretteville Neuilly - France 33(0) Fax : 33(0) Document: IM By PB Date: 18/11/2005 OPTA-PERIPH 8 Av. de Bretteville 92 200 Neuilly - France 33(0)6 85 43 82 78 - Fax : 33(0)6 07 18 28 07 User: AIR CONDITIONER ATEX CE II 3G Supplier : OPTA-PERIF Ref : Q/N 0510278 Rev.: 0 Document: IM 050312

More information

AEU1 Electric Forced-Air Explosion-Proof Heater Owner s Manual, Version: AEU1-OM-B This manual covers installation, maintenance, repair, and replacement parts. Forced-Air Heater for Hazardous Locations

More information

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX) COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX) TECHNICAL DESCRIPTION EDITION: TB CFC200-REV3-2015-04-07 IMPORTANT: Please note, that all mounting and wiring as well as all changing or adjustment at the

More information

Fan Heaters Type VLEx

Fan Heaters Type VLEx Fan Heaters Type VLEx Fan Heater type VLEx has been designed for Explosion Proof industrial applications. Our Fan Heaters are characterized mainly by their quality, both in used materials and design. Liquids

More information

PolyGard 2-channel Gas Controller MGC-03

PolyGard 2-channel Gas Controller MGC-03 PolyGard 2-channel Gas Controller MGC-03 DESCRIPTION Gas measuring and monitoring controller based on state-ofthe-art micro-technology with integrated buzzer for continuous monitoring of the ambient air

More information

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection unit Type GD Heavy Duty Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx

More information

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz.

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz. Chemical Thermo-con Series HED How to Order Part number of set (Temperature controller + Heat exchanger) Note) The name plate on the Chemical Thermo-con shows the model numbers of the controller and heat

More information

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres PRODUCT OVERVIEW Light fittings, boxes & custom built control panels for explosive atmospheres LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones

More information