ClimaSys Resistance heaters Selection guide

Size: px
Start display at page:

Download "ClimaSys Resistance heaters Selection guide"

Transcription

1 Selection guide Insulated resistance heaters Power W Voltage Type of connection Terminal block Cable DC X AC X DC X AC X DC X AC X AC X DC X AC X AC X DC X AC X AC X 94

2 Insulated resistance heaters with fan Power W Voltage Type of connection Terminal block Cable AC X 1 Ventilation systems Thermofans Power (W) Voltage Type of connection Terminal block Cable / AC X / AC X 2 Air-air exchangers Power W Voltage Type of connection Terminal block Cable DC X AC X DC X AC X AC X DC X AC X AC X DC X AC X AC X DC X AC X AC X 3 Air-water exchangers with fan Fixing accessories Power W Votlage Type of connection Terminal block Cable AC X AC X AC X AC X AC X AC X Description Set of 5 studs Set of 5 studs, DIN rails and screws 7 Calculation and selection aid software 4 Cooling units 5 6 Control devices 95

3 INSULATED RESISTANCE HEATERS 10 W and 20 W insulated resistance heaters General characteristics Compact resistance heater which prevents the formation of condensation and ice. Designed for a better natural convection and a high thermal performance. Extremely compact resistance heater. Extruded aluminium body. Features a plastic cover UL94 V0, light grey, to avoid direct contact with the aluminium radiator. Surface temperature limited to 70 C. Fitted with an insulated cable. Double insulated. PTC technology range. Quick attachment by clips into 35 mm DIN rail. Certifications compliant with UL and VDE and EC Marking. Usage conditions The resistance heaters should be used with a hygrometer switch or a thermostat (thermostat or 87558, hygrostat 87560) to control temperature or humidity within the enclosure. The enclosure should be sealed to prevent the entry of external air. An electrical protection device should be installed on the supply side of the unit. Characteristics Power at 0ºC 10W 20W Voltage V 12-36V V 12-36V Technology PTC Surface temperature <70ºC, except for grill for higher protection Electrical connection Insulated cable Quick attachment By clips into 35 mm DIN rail (EN 50022) Cover Plastic UL94 V0 Operating position Vertical Operating temperature ºC ºF Degree of protection IP Class II IP 20 (double insulated) Certifications Compliant with VDE and UL on request 96

4 INSULATED RESISTANCE HEATERS Dimensions 1 Ventilation systems Air-air exchangers L (mm) clip de fixation clip sur 35 rail mm DIN 35 DIN mmrail 98 3 Air-water exchangers Calculation and selection aid software 6 Control devices 5 4 Cooling units 97

5 INSULATED RESISTANCE HEATERS 55 W W 147 W insulated resistance heaters General characteristics Compact resistance heater which prevents the formation of condensation and ice. Designed for a better natural convection and a high thermal performance. Extremely compact resistance heater. Extruded aluminium body. Features a plastic cover UL94 V0, light grey, to avoid direct contact with the aluminium radiator. Surface temperature limited to 70 C. Fitted with an insulated cable 2.5 mm 2. Double insulated. PTC technology range. Quick attachment by clips into 35 mm DIN rail (EN 50022). Certifications compliant with UL and VDE and EC Marking. Usage conditions The resistance heaters should be used with a hygrometer switch or a thermostat (thermostat or 87558, hygrostat 87560) to control temperature or humidity within the enclosure. The enclosure should be sealed to prevent the entry of external air. An electrical protection device should be installed on the supply side of the unit. Characteristics Power at 0ºC 55 W 102 W 147 W Voltage V V V V 12-36V V V 12-36V V Technology PTC Surface temperature <70 ºC, except for grill for higher protection Electrical connection Four-pole terminal for 2.5 m 2 Quick attachment By clips into 35 mm DIN rail (EN 50022) Cover Operating position Plastic UL94 VO Vertical Operating temperature ºC ºF Degree of protection IP Certifications Class II IP 20 (double insulated) Compliant with VDE and UL on request 98

6 INSULATED RESISTANCE HEATERS Dimensions 2 Air-air exchangers 1 Ventilation systems L (mm) Air-water exchangers Performances diagram 4 Cooling units Heating power/external temperature Diagram Heating power (W) Calculation and selection aid software 6 Control devices External temperature ( C) 99

7 INSULATED RESISTANCE HEATERS WITH FAN 177 W General characteristics Compact resistance heater which prevents the formation of condensation and ice. Designed for a better natural convection and a high thermal performance. Extremely compact resistance heater. Extruded aluminium body. Features a plastic cover UL94 V0, light grey, to avoid direct contact with the aluminium radiator. Surface temperature limited to 70 C. Fitted with an insulated cable 2.5 mm 2. Double insulated. PTC technology range. Quick attachment by clips into 35 mm DIN rail (EN 50022). Certifications compliant with UL and VDE and EC Marking. Usage conditions The resistance heaters should be used with a hygrometer switch or a thermostat (thermostat or 87558, hygrostat 87560) to control temperature or humidity within the enclosure. The enclosure should be sealed to prevent the entry of external air. An electrical protection device should be installed on the supply side of the unit. Characteristics Power at 0ºC Voltage Technology Surface temperature 177 W AC 230 V; Hz PTC 50 ºC max. in the enclosure, 100 ºC over grill for higher protection (for an external temperature of 20 ºC/68 ºF) Service life 40,000 h at 40 ºC Air flow 13.8 m 3 /h Electrical connection Two-pole terminal for 2.5 m 2 Quick attachment By clips into 35 mm DIN rail (EN 50022) Cover Operating position Plastic UL94 V0 Vertical Operating temperature ºC ºF Degree of protection IP Certifications Class II IP 20 (double insulated) Compliant with VDE and UL on request 100

8 INSULATED RESISTANCE HEATERS WITH FAN Dimensions 7 Calculation and selection aid software 6 Control devices 5 1 Ventilation systems 4 Cooling units 3 Air-water exchangers 2 Air-air exchangers 101

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection 7 0 Selection guide TO CONTROL THE TEMPERATURE Respects the entered value Compact fixed thermostats Preset factory temperature: NA (blue button):, 0, ºC for the resistance heater. (red button):, 0, ºC

More information

Enclosure Heaters and Fan Heaters

Enclosure Heaters and Fan Heaters Enclosure Heaters and Fan Heaters ISC carries innovative products for heating, cooling, temperature and humidity control of electronic enclosures. Our products are renowned for their reliability, long

More information

HEATING. Anticondensation Heaters

HEATING. Anticondensation Heaters HEATING Anticondensation Heaters Application Enclosure heaters are often necessary to prevent failures or corrosion caused by low temperatures or high humidity inside the enclosure. Such conditions are

More information

CR 027 PTC Fan Heater W

CR 027 PTC Fan Heater W CR 027 PTC Fan Heater 400-650 W Compact fan heater Heating power adjusts to ambient temperature Integrated adjustable thermostat Built-in overheat protection DI rail mountable The semiconductor CR 027

More information

Heating THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

Heating THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES Heating THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES HEATING Anticondensation Heaters Application Enclosure heaters are often necessary to prevent failures or corrosion caused by low temperatures

More information

Cooling unit Mechanical control

Cooling unit Mechanical control ClimaSys CU Cooling unit Mechanical control Top-mounting models, ref. NSYCU760W2VR- NSYCU10W2VR- NSYCU1460W2VR J 26 A B 8 K 2 0 C D E H F G Cut-out template for top mounting without intermediate frame.

More information

Product Description. Options. Fan Voltage. Electrical Connections Technical Data - Key Characteristics

Product Description. Options. Fan Voltage. Electrical Connections Technical Data - Key Characteristics Cirrus 25/1 The Cirrus 25/1 range of fan heaters uses PTC ceramic heating technology to provide the user with a product ideally suited to climate control. The heater can be controlled independently to

More information

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories Product Catalogue Content Heating Small semiconductor Heater HGK 047 Series 3 Semiconductor Heater HG 040 Series 4 Semiconductor Heater HG 140 Series 5 Semiconductor Heater CS 060 Series 6 Semiconductor

More information

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue Product Catalogue Thermal Management Products & Accessories from STEGO successfully used worldwide for control panels and enclosures for traffic control and monitoring systems in the transport industry

More information

Thermal Management Products & Accessories for Enclosures

Thermal Management Products & Accessories for Enclosures Thermal Management Products & Accessories for Enclosures Photo: STEGO International Headquarters in Germany STEGO, Inc. 1395 S. Marietta Parkway Building 800 Marietta, GA 30067 Tel: (770) 984-0858 Fax:

More information

Stego accessories for cabinets

Stego accessories for cabinets www.klinkmann.com Stego accessories for cabinets page Small semiconductor Heater RC 016 2 Touch-Safe Small Heater CSK 060 3 Semiconductor Heater HG 140 4 Hazardous area Heater CREx 020 5 Touch-Safe Heater

More information

Anti Condensation Heaters

Anti Condensation Heaters Anti Condensation Heaters Thermal Management Products & Accessories from SAN successfully used worldwide for control panels and enclosures for traffic control and monitoring systems in the transport industry

More information

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOG 2014 2 PERFECT THERMAL MANAGEMENT PRODUCT CATALOG - STEGO, Inc. STEGO, Inc. PRODUCT CATALOG - STEGO, Inc. PERFECT THERMAL MANAGEMENT 3 INNOVATION Thermal

More information

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOGUE 2018 2 COMPANY PRODUCT CATALOGUE - STEGO STEGO Catalogue 2018 STEGO - PRODUCT CATALOGUE PERFECT THERMAL MANAGEMENT 3 Global presence in Thermal Management

More information

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOGUE 2018 STEGO Catalogue 2018 Global presence in Thermal Management This catalogue contains the full range of STEGO products for protection of electronic

More information

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOGUE 2018 STEGO Catalogue 2018 Global presence in Thermal Management This catalogue contains the full range of STEGO products for protection of electronic

More information

Rittal roof-mounted fans Efficiency on top

Rittal roof-mounted fans Efficiency on top Rittal roof-mounted fans Efficiency on top 2 Climate control/roof-mounted fans The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have bundled our

More information

Application. Specifications. Finish

Application. Specifications. Finish Spec-00051 I( McLean Electronics Cooling Thermal Accessories McLean Electronics Cooling: Thermal Accessories Touch-Safe Heaters Industry Standards curus Component Recognized; File No. E150057 IP 20 CE

More information

Scha tschra Hei u g E c sure heater R sista ces chauffa tes Scha e astverwar i ge. Risca dat re a tic de sa Resiste cia ca efact ra 3105 XXX

Scha tschra Hei u g E c sure heater R sista ces chauffa tes Scha e astverwar i ge. Risca dat re a tic de sa Resiste cia ca efact ra 3105 XXX Scha tschra Hei u g E c sure heater R sista ces chauffa tes Scha e astverwar i ge V r ee e e t f r apparats p Risca dat re a tic de sa Resiste cia ca efact ra 305 XXX tage I sta ati s u d Bedie u gsa eitu

More information

TOUCH-SAFE HEATERS INDUSTRY STANDARDS

TOUCH-SAFE HEATERS INDUSTRY STANDARDS 763.576.3200 SPEC-00051 L763.422.2211 ACCESSORIES ENCLOSURE HEATERS ACCESSORIES ENCLOSURE HEATERS TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP 20 CE APPLICATION

More information

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE 763.576.3200 SPEC-00051 O763.422.2211 THERMAL MANAGEMENT ACCESSORIES ENCLOSURE HEATERS Accessories Enclosure Heaters TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP

More information

Rittal roof-mounted fans

Rittal roof-mounted fans Rittal roof-mounted fans 2 Climate control/roof-mounted fans The whole is more than the sum of its parts The same is true of Rittal The System. Keeping this in mind, we have bundled our innovative enclosure,

More information

Performance Data. curus Component Recognized; File No. E IP 20

Performance Data. curus Component Recognized; File No. E IP 20 TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP 20 CE APPLICATION Protect electrical, mechanical equipment from low temperatures, condensation, and corrosion with

More information

LC1 Modular Ceiling Loudspeaker Range. en Installation note

LC1 Modular Ceiling Loudspeaker Range. en Installation note LC1 Modular Ceiling Loudspeaker en Installation note LC1 Modular Ceiling Loudspeaker Table of Contents en 3 Table of contents 1 System Overview 4 1.1 Housings 4 1.2 Loudspeakers 5 1.3 Accessories 6 2

More information

THERMASREG TR 040 THERMASREG TR 060

THERMASREG TR 040 THERMASREG TR 060 THERMASREG TR 040 THERMASREG Temperature controllers, one-step, Mechanical temperature controllers wet room temperature controllers THERMASREG TR 040 with switching output and stainless steel capillary

More information

ClimaSys Technical Guide Preventing condensation

ClimaSys Technical Guide Preventing condensation ClimaSys Technical Guide Preventing condensation Contents The problem 2-3 Ultra thin resistance heaters 4-7 Guide to our new solutions 8-9 Overview of the offer 10-11 Unsettled global weather patterns

More information

SELECTION GUIDE. Industrial Thermoregulation. Products for panels and enclosures

SELECTION GUIDE. Industrial Thermoregulation. Products for panels and enclosures SELECTION GUIDE Industrial Thermoregulation Products for panels and enclosures 7T Series - Thermo-Hygrostat and Thermostats 7F Series - Filter Fans 7H Series - Panel Heaters Perfect climate inside panels

More information

Power. Average noise level (DIN EN ISO 4871)

Power. Average noise level (DIN EN ISO 4871) 21m 3 /h to 102m 3 /h Very low noise Minimal depth in Functional design Time-saving installation Filter fans are used to provide an optimum climate in s. The interior temperature of an can be reduced by

More information

Fan speed controller Type Saginomiya XGE

Fan speed controller Type Saginomiya XGE Data sheet Fan speed controller Type Saginomiya Fan speed controller stabilizes condensing pressure by changing condenser s fan speed. The controller reduces fan noise and saves energy in low ambient conditions.

More information

Thermal management for your cabinets!

Thermal management for your cabinets! ELECTRIC CABINET HEATERS LIGHTS CONTROLLER ELECTRIC CABINET COOLERS Thermal management Thermal management for your cabinets! MORE THAN 55 YEARS the specialist for individual electric cabinet heaters and

More information

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV FILTER FANS SERIES LV ROOF MOUNTED FAN For the ventilation of control cabinets, enclosures and housings Different filter mats for dust collection LV series offers low shape and quick mounting EMC versions

More information

Life insurance for your electronics

Life insurance for your electronics ELECTRO-TECHNOLOG FOR INDUSTR Life insurance for your electronics The formation of condensation is one of the biggest dangers for electrical enclosures. As long as they are working under load, their own

More information

Thermal control. Overview. Adjustable thermostats. Double-adjustable thermostat. Different installation methods. The new quick-fixing systems:

Thermal control. Overview. Adjustable thermostats. Double-adjustable thermostat. Different installation methods. The new quick-fixing systems: Overview Adjustable thermostats O (blue button) with normally open contact to control the starting of a fan when the temperature exceeds the displayed maximum value. C (red button) with normally closed

More information

electronics Protection

electronics Protection Climate control electronics PROTECTION 10/2017 PRODUcT catalog WWW.SCHROFF.PENTAIR.co.uk Main Catalogue Content Cabinets...... 1 Climate control Overview Wall mounted cases......... 2 Accessories for cabinets

More information

THERMAL MANAGEMENT. Outdoor 3.13 to

THERMAL MANAGEMENT. Outdoor 3.13 to Tecoras Outdoor.1 to.18.15 Tecoras Thermal Management Strong points TEC00087 The permanent increase ofheat dissipation in electronic components and the higher packaging density of the equipment caused

More information

+ = ECO-STAR System. Ecology Series (Distribution boxes) + Star Series (Boxes for industrial sockets) ECOLOGY Technical Specifications

+ = ECO-STAR System. Ecology Series (Distribution boxes) + Star Series (Boxes for industrial sockets) ECOLOGY Technical Specifications + = ECO-STAR System Ecology Series (Distribution boxes) + Star Series (Boxes for industrial sockets) STAR Technical Specifications - Degree of protection: IP65. - Resistance to impact: IK08. - Glow wire

More information

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10.

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10. 2 Device technology XS/S 1.1 2CDC 071 115 F0008 The Interface XS/S 1.1 integrates the Intrusion Alarm Panel L240 into the KNX intelligent installation system. It is connected to the XIB bus of the Intrusion

More information

Positive Temperature Coefficient (PTC2) Heater Manual

Positive Temperature Coefficient (PTC2) Heater Manual 2ND GENERATION Positive Temperature Coefficient (PTC2) Heater Manual PTC2-MANUAL 1.5 Read and understand this manual prior to operating or servicing the products. PTC2 Heater Systems are manufactured and

More information

Eldon Product Overview

Eldon Product Overview Eldon Product Overview Product overview Floor Standing Enclosures page 4 Thermal Management page 32 Human Machine Interface page 26 Wall Mounted Enclosures page 12 Accessories page 38 Terminal Boxes page

More information

Type CODE Speed Heating Cooling

Type CODE Speed Heating Cooling CLIMA CANAL HYBRID - Low Temperature radiator - Heating and cooling - Build-in height of 10 > 14.5 cm CLIMA CANAL - Low Temperature radiator - Heating - Build-in height of 8.5 > 13 cm 24V EC MOTOR High

More information

RIVERA P5000. Folding awning P5000

RIVERA P5000. Folding awning P5000 RIVERA Beschreibung Description min. 200 cm max. 500 cm 8 25 Wall mounting 8 25 Top fixation min. 200 cm max. 700 cm Terrace roof system comprising an aluminium extruded structure and integrated fabric

More information

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W Comfort Ceiling Fan Coil System INDULVENT ec NEW Draught-free ambient air distribution with cooling capacity up to 2600 W Low sound power levels Only electrical, cooling water and condensate connections

More information

Heaters, Thermostats and Hygrostats

Heaters, Thermostats and Hygrostats Heaters, Thermostats and Hygrostats 154 Automática Electrónica y Control, S.L. Lacy, 30 Acc. - 08202 Sabadell (Barcelona) Tel 937 207 066 Fax 937 209 999 www.automatica-elec.es info@automatica.cat ELECTRO-TECHNOLOGY

More information

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page How to Select and Size Enclosure Thermal Management Systems Follow the steps detailed in this white paper for optimal

More information

CMD420 / CMD421 Series

CMD420 / CMD421 Series 3 T M CMD420 / CMD421 Series Digital Current Relay (Overcurrent and Undercurrent) For Three-Phase AC Systems Technical Bulletin NAE1032810 / 06.2016 CMD420 / CMD421 Digital overcurrent and undercurrent

More information

WHITE PAPER: Thermal Management Solutions

WHITE PAPER: Thermal Management Solutions WHITE PAPER: Air Conditioners What is Air Conditioning? Air conditioning by definition is a means to cool and remove humidity from an environment, such as an enclosure, through use of a refrigerant cooling

More information

Element: Stainless steel (encapsulated) resistance wire. Fresh-Air-Fan 2 capacities. Standing model IP24

Element: Stainless steel (encapsulated) resistance wire. Fresh-Air-Fan 2 capacities. Standing model IP24 Heaters Electric Dimplex room heaters Sinus Jevi finned tube heaters Eurom heaters Air cleaner Eurom electrical heaters budget series. and professional series with a higher airflow Number Description Number

More information

Contents. External and internal tight cabinets, heating and cooling systems. IP55 outdoor distribution cabinets 1-4

Contents. External and internal tight cabinets, heating and cooling systems. IP55 outdoor distribution cabinets 1-4 The assembly of a modern and universal access system based on outdoor BKT Elektronik distribution cabinets is possible thanks to the application of cutting - edge solutions in compliance with Polish as

More information

LB3-PCx50 Premium Cabinet Loudspeakers

LB3-PCx50 Premium Cabinet Loudspeakers Communications Systems LB3-PCx Premium Cabinet s LB3-PCx Premium Cabinet s High quality music and speech reproduction Weatherized, suited for sheltered outside use Prepared for Bosch WLS, EOL and DMY pcb

More information

Anti-condensation and climate control

Anti-condensation and climate control Anti-condensation and climate control The new anti-condensation fan heater EH-V series with PTC Engineering Costruzioni Elettromeccaniche P. Torresan http://www.torresansrl.it/ Anticondensation Fan Heater

More information

The insurance for your regulation!

The insurance for your regulation! HEATERS WITH INTEGRATED THERMOSTAT PTC-HEATERS FAN- AND BLOWER HEATERS EX-HEATERS Product catalogue The insurance for your regulation! MORE THAN 55 YEARS the specialist for individual electric cabinet

More information

Accessory Products

Accessory Products Thermostat Designed to provide air temperature control and monitoring in cabinets. Thermostat NC (Normally Closed) for the control of heaters and heater fans. Thermostat NO (Normally Open) for the control

More information

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE Insulation monitoring device with integrated load and temperature monitoring and locating current injector for insulation fault location systems for medical IT systems _D00043_02_D_XXEN/09.2016 Insulation

More information

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame Product Selection 225 A, I-Frame Assembled 225 A I-Frame Interrupting Rating/Breaking Capacity Thermal-Magnetic Circuit Breakers Interrupting Rating (50/60 Hz), UL 489/CSA C22.2-5, No. 5-02 [ka] Thermal-Magnetic,

More information

Advantages / Characteristics

Advantages / Characteristics Air to Air 50 W 30 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 70 W 36 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 75 W 30 W cooling capacity 130x109x163mm (LxBxH) 1,5 kg

More information

Interface Modules for SENTRI

Interface Modules for SENTRI EQUIPMENT INTERFACED Data and Installation Interface s for SENTRI Low voltage (LV) / SEN-INT-INPUT 1- Interface (low voltage) SEN-INT-OUTPUT 1- & 1- Interface (low voltage) SEN-INT-4IO # 4- / Interface

More information

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,

More information

SIVACON sicube 8MF system cubicles 16/2 Introduction 16/3 8MF system cubicles 16/4 Preconfigured cubicles

SIVACON sicube 8MF system cubicles 16/2 Introduction 16/3 8MF system cubicles 16/4 Preconfigured cubicles System Cubicles, System Lighting and System Air-Conditioning SIVACON sicube 8MF system cubicles /2 Introduction /3 8MF system cubicles /4 Preconfigured cubicles SIVACON 8MF/8MR system lighting /6 Compact/slimline

More information

BRIZA_038. EC MOTOR Briza Hybrid: High performance technology

BRIZA_038. EC MOTOR Briza Hybrid: High performance technology EC MOTOR Briza Hybrid: High performance technology BRIZA_038 Installation into a wall recess (Built In Wall) 2-pipe connection / 4-pipe connection - Heating & cooling - units built-in H 38 cm, D 12 cm

More information

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL IRIS IP65 IRIS UNISCAN APPLICATION MANUAL 01/08/05 DESCRIPTION TABLE OF CONTENTS PAGE IRIS - UNISCAN... 1 SPECIFICATION... 1 SUPPLY VOLTAGE: -... 1 OUTPUTS: -... 1 TRANSMISSION: -... 1 CABLE: -... 1 FLAME

More information

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems) ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) IR425-D4_D00039_04_D_XXEN/05.2017 ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits

More information

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage LINETRAXX VME420 Multi-functional monitoring relay for undervoltage, overvoltage and frequency monitoring in AC/DC systems with separate supply voltage VME420_D00026_01_D_XXEN/06.2016 LINETRAXX VME420

More information

Quatro canal Super-powered climate control for 4-pipe systems

Quatro canal Super-powered climate control for 4-pipe systems Quatro canal Super-powered climate control for 4-pipe systems Heating, cooling, ventilation. Despite its compact dimensions, the Quatro Canal is a powerful main heating system, cooling unit and ventilation

More information

Ledinaire Batten Simply great LED

Ledinaire Batten Simply great LED Lighting Simply great LED The Ledinaire range contains a selection of popular off-the-shelf LED luminaires that comes with the high Philips quality levels at a competitive price. Reliable, energy efficient

More information

Acessories BROCHURE JUNHO 2013

Acessories BROCHURE JUNHO 2013 Acessories BROCHURE JUNHO 2013 Accessories D-ZS 087-20 Digital display for displaying the flame signal For optimal alignment of flame sensor with the ball flange and/or for displaying the configuration

More information

DTA. Motor thermistor relay. Benefits. Description

DTA. Motor thermistor relay. Benefits. Description DTA Motor thermistor relay Description DTA71 and are precise Motor thermistor monitoring relays. They can monitor up to 6 motor temperatures through the motor internal temperature. PTCs are connected in

More information

Line Smoke Detector LRMX

Line Smoke Detector LRMX Line Smoke Detector LRMX Motorized detector head User-friendly commissioning via automatic selfadjustment Disturbance-protected operation via automatic electromechanical tracking of the detector head during

More information

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16 TraceTek TTSIM-1A TraceTek Sensor Interface Module with Relay Installation/OPERATION Instructions Approvals and Certifications TYPE NM General Signaling Equipment 76LJ Only AC versions are UL listed and

More information

NGC-40 Advanced Heat-Tracing Control System

NGC-40 Advanced Heat-Tracing Control System NGC-40 Advanced Heat-Tracing Control System Local configuration and monitoring with Raychem Touch 1500 touch screen display Heat-tracing system NGC-40 system Remote configuration and monitoring with Raychem

More information

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.

More information

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.

More information

Cabinet Cooler Systems

Cabinet Cooler Systems Cooler Systems Cooler Systems Stop electronic control downtime due to heat, dirt, and moisture! maintain NEMA 4, 4X, and 12 integrity. All are and compliant! What is an EXAIR Cooler System? A low cost,

More information

Loadstar AC/DC Systems

Loadstar AC/DC Systems WARRANTY W A R R A N T Y YEAR The Loadstar range of AC/DC central battery units comply with the latest relevant European and British standards. High quality, cost effective units provide secure sources

More information

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE / 3 GM20 Digital Ground Continuity Relay For AC Systems Technical Bulletin NAE03230 / 0.20 GM20 Ground continuity monitor For AC systems Description The GM20 monitors the loop resistance of ground conductors

More information

CONTROLS FOR ELECTRIC RADIATORS AND TOWEL RAILS

CONTROLS FOR ELECTRIC RADIATORS AND TOWEL RAILS CONTROLS FOR TOWEL RAILS ErP STONE ECO PLUS pag. 06-07 ErP WHISTLE ECO PLUS pag. 08-09 DUETTO pag. 10-11 MOEBIUS pag. 12-13 AQUARIUS pag. 14-15 VARIHEAT pag. 16-17 POSEIDONE PW pag. 18-19 SHORTY PW pag.

More information

Control THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

Control THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES Control THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES CONTROL CONTROLLO THV THR THERMOSTATS Compact Thermostat for DI 35 mm. rail mounting. Based on bimetallic junction, provides high capacity

More information

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE TRACENET TM GENESIS APPLICATION OVERVIEW Control and monitoring systems can play an essential role in heat tracing applications which

More information

Maximum rated temperature Maximum ambient temperature

Maximum rated temperature Maximum ambient temperature 901A Heat conducts through the metal mounting plate to trigger the thermostat. Provide good and stable thermo- control and minimum EMC interference. Has been widely applied in kitchen cooking products

More information

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012372 / 03.2015 isopv

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS GENERAL INFORMATION Please read these instructions and keep them in a safe place. These instructions must

More information

Tubular Heaters. Finned Tubular Heaters. Threaded Immension Heaters

Tubular Heaters. Finned Tubular Heaters. Threaded Immension Heaters Tubular Heaters Finned Tubular Heaters Finned construction is ideal for transferring heat to air or other gases. Finned tubular heaters are manufacturted in a very wide range of dimensions and power ratings.

More information

Safe Enclosure Cooling

Safe Enclosure Cooling Safe Enclosure Cooling Heat Exchangers 2017 www.seifertsystems.com Table of Contents Page Product Overview 3 Air / water heat exchangers 4-18 Air / air heat exchangers 19-25 Thermal Management solutions

More information

SINGLE PHASE RANGE BD BD 19/19 M4 1/5 BD 19/19 M6 1

SINGLE PHASE RANGE BD BD 19/19 M4 1/5 BD 19/19 M6 1 BD/BDcubic CENTRIFUGAL LOW PRESSURE FANS Closed Motor Range of 8 different fan models, from19/19 () to 9/9 (15/15), provided with single phase 4 and, 6 pole motors and three phase 6 pole motors. Airflow

More information

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P 1 of 13 These instructions should be read by: The specifying engineer. The installation engineer. The user. The service engineer. WARNINGS Failure

More information

Heatless Desiccant Compressed Air Dryers

Heatless Desiccant Compressed Air Dryers Heatless Desiccant Compressed Air Dryers Pro Dry Heatless Desiccant Compressed Air Dryer Inspired by its sophisticated predecessor, SMC can now boast an additional ten models to enhance the current Pro

More information

Easy installation Certified for zones 1 and 21 High IP degree of protection

Easy installation Certified for zones 1 and 21 High IP degree of protection Actuating elements Features Easy installation Certified for zones 1 and 21 High IP degree of protection A large number of variants and versions of actuating elements are available for the ComEx control

More information

Product Management, Rev 3 December 2009

Product Management, Rev 3 December 2009 Climate Control Product Overview Product Management, Rev 3 December 2009 Why climate control? Common Causes of Electrical/Electronic Equipment Failure Name/Department of author Vibration 21% Humidity 16%

More information

Bulletin 1608N MiniDySC Dynamic Sag Corrector

Bulletin 1608N MiniDySC Dynamic Sag Corrector User Manual Bulletin 1608N MiniDySC Dynamic Sag Corrector Single Phase Voltage Sag Correction 2...6 Amps (250...750 VA) Important User Information Solid-state equipment has operational characteristics

More information

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION PRODUCTS INDEX EXPERT NANO 1LT 06 PLUS200 EXPERT THR 34 EXPERT NANO 3CF 08 PLUS300 EXPERT U THR 36 EXPERT NANO 4CK 10 PLUS1000 THR 38 EXPERT NANO 2ZN

More information

Trench Heating Katherm QK

Trench Heating Katherm QK Trench Heating Katherm QK Tested acc. to: EN 16430 March 2015 EC technology: the ace up your sleeve New EC technology is a revolution in electronic drive technology. High output, yet whisper quiet, even

More information

CoreLine Waterproof the clear choice for LED

CoreLine Waterproof the clear choice for LED Lighting CoreLine Waterproof the clear choice for LED CoreLine Waterproof Whether for a new building or renovation of an existing space, customers want lighting solutions that provide quality of light

More information

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM TTC-1 TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION The nvent RAYCHEM TraceTek TTC-1 sensing module is used with TraceTek sensing cables to detect liquid leaks.

More information

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry LINETRAXX VMD420 Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry VMD420_D00137_02_D_XXEN/06.2016 LINETRAXX VMD420 Multi-functional

More information

Marathon Special Products

Marathon Special Products Marathon Special Products Fused Disconnect Switch Specifications 30 amps 600 volts AC Line/Load #4-18 AWG Factory & Field Wiring Minimum indicator voltage 90V-AC Din-Rail mountable on any 35mm wide rail

More information

Superdew 3. Hygrometer. Operating Instructions

Superdew 3. Hygrometer. Operating Instructions Superdew 3 Hygrometer Operating Instructions Shaw Moisture Meters (UK) Ltd Len Shaw Building Bolton Lane Bradford BD2 1AF England t. +44 (0) 1274 733582 f. +44 (0) 1274 370151 e. mail@shawmeters.com www.shawmeters.com

More information

Q (m3/h)

Q (m3/h) COMPARISON 35 3 25 2 15 5 25 5 75 125 15 175 2 225 25 Design point Q (m 3 /h) comparative summary model Q (m 3 /h) Ps (Pa) Pt (Pa) P abs (kw) P recom (kw) efficiency (%) TWIN BOX BD 7/7 M4,12kW (TW25155)

More information

TROPO 15W Dimmable LED Driver

TROPO 15W Dimmable LED Driver Features TROPO switch mode power supply technology is designed to generate one constant current output from an AC input, and work with industry standard lighting controls in dimming applications. 120VAC

More information

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date: Installation and Operating instructions for C9900-U330-0010 battery pack Version: 2.0 Date: 2017-03-23 Table of contents Table of contents 1 Foreword 3 1.1 Notes on the Documentation 3 1.1.1 Liability

More information

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems) Insulation monitoring device for unearthed AC/DC control circuits (IT systems) TDB103005en/05.2013 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) Product description The

More information