+ = ECO-STAR System. Ecology Series (Distribution boxes) + Star Series (Boxes for industrial sockets) ECOLOGY Technical Specifications

Size: px
Start display at page:

Download "+ = ECO-STAR System. Ecology Series (Distribution boxes) + Star Series (Boxes for industrial sockets) ECOLOGY Technical Specifications"

Transcription

1 + = ECO-STAR System Ecology Series (Distribution boxes) + Star Series (Boxes for industrial sockets) STAR Technical Specifications - Degree of protection: IP65. - Resistance to impact: IK08. - Glow wire resistance: 650 ºC. - Ball pressure test: 70 ºC. - Ambient temperature range: -25 ºC / +40 ºC. - Maximum operating voltage: 1000 V AC/1500 V DC. - Double insulation: Class II. STAR Certifications ECOLOGY Technical Specifications - Degree of protection: IP65. - Resistance to impact: IK08. - Glow wire resistance: ABS: 650 ºC Polycarbonate: 750 ºC - Ball pressure test: 70 ºC. - Ambient temperature range: -25 ºC / +40 ºC. - Maximum operating voltage: 1000 V AC/1500 V DC. - Double insulation: Class II. ECOLOGY Certifications Compliant with the Low Voltage Directive 2014/35/EU. Standards: UNE-EN and UNE-EN (as applicable). Compliant with the Low Voltage Directive 2014/35/UE. Standards: UNE-EN and IEC

2 STAR IP65 Boxes for industrial sockets NEW IP65 Boxes for industrial sockets CSNPLUS - 436x142x CSN6PT 1x6 DIN rail 436x142x CSN9PT 1x9 DIN rail 436x210x CSN12PT 1x12 DIN rail 436x310x CSN18PT 1x18 DIN rail 436x418x CSN24PT 2x12 (24) DIN rail 688x310x Frame and base in ABS RAL 7035 grey. PC transparent window, tinted with UV protection. IP65 - Surface. IP65 Boxes for industrial sockets. With neutral and earth bars CSNPLUS/RR - 436x142x CSN6PT/RR 1x6 DIN rail 436x142x CSN9PT/RR 1x9 DIN rail 436x210x CSN12PT/RR 1x12 DIN rail 436x310x CSN18PT/RR 1x18 DIN rail 436x418x CSN24PT/RR 2x12 (24) DIN rail 688x310x Frame and base in ABS RAL 7035 grey. PC transparent window, tinted with UV protection. IP65 - Surface. /RR: With neutral and earth bars. 2 ECO-STAR SYSTEM

3 IP 65 NEW IP65 Boxes for industrial sockets with knock-out lids Reference No. of modules Dimensions Frame and base in ABS RAL 7035 grey. Transparent PC tinted window, with UV protection. IP65 - Surface. No. of Weight PCSNPLUS - 436x142x PCSN6PT 1x6 DIN rail 436x142x PCSN9PT 1x9 DIN rail 436x210x PCSN12PT 1x12 DIN rail 436x310x PCSN18PT 1x18 DIN rail 436x418x PCSN24PT 2x12 (24) DIN rail 688x310x IP65 Boxes for industrial sockets with knock-out lids. With neutral and earth bars Reference No. of modules Dimensions Frame and base in ABS RAL 7035 grey. Transparent PC tinted window, with UV protection. IP65 - Surface. /RR: With neutral and earth bars. No. of Weight PCSNPLUS/RR - 436x142x PCSN6PT/RR 1x6 DIN rail 436x142x PCSN9PT/RR 1x9 DIN rail 436x210x PCSN12PT/RR 1x12 DIN rail 436x310x PCSN18PT/RR 1x18 DIN rail 436x418x PCSN24PT/RR 2x12 (24) DIN rail 688x310x Each box includes Reference Plain 16A / Schuko IP67 IP44/IP54 Schuko Ref Ref.: Ref.: PCSNPLUS PCSN6PT PCSN9PT PCSN12PT PCSN18PT PCSN24PT ECO-STAR SYSTEM 3

4 STAR KNOCK-OUT IP65 Boxes for industrial sockets Knock-out lids Reference Description Bases Current (A) Poles IP Plain : Supplied assembled. Remove the cover in order to install sockets. Flush-fit 16 3P+N+E IP44 - IP67 2P+E Flush-fit 32 3P+E IP44 - IP67 3P+N+E A cover: Supplied in the box. Screw-in cover for socket installation. Flush-fit 16 2P+E 3P+E IP44 - IP67 Schuko-type 16 2P+E IP Schuko cover: Supplied in the box. Screw-in and clip-on cover for socket installation. Schuko-type 16 2P+E IP44 - IP54 10 Possibility of lids and installation of sockets and 4. PLAIN COVER (Ref ) It is supplied assembled, with knockouts for the installation of pilot lights or pushbuttons. Remove the plain cover in order to install sockets. - 16A (3P+N+E) - IP44-IP A IP44-IP A COVER (Ref ) Screw-in cover for socket installation: - 16A (2P+E) (3P+E) IP44-IP67. - Schuko-type: 16A IP SCHUKO COVER (Ref ) Screw-in and clip-on cover for Schuko-type 16A sockets - IP44-IP54. 4 ECO-STAR SYSTEM

5 STAR complet Boxes for industrial sockets Special assemblies: 4 different possibilities ASSEMBLE IT YOURSELF ORDER FROM THE FACTORY Plain boxes. Boxes with knock-out. Boxes with assembled and wired power sockets. Boxes with assembled and wired power sockets and protections. How to proceed 1. SELECT THE BOX. 2. CHOOSE THE POWER SOCKETS. 3. INDICATE THE REQUIRED PROTECTION. 4. SUBMIT ALL THE INFORMATION TO OUR TECHNICAL DEPARTMENT. You can request a quotation and technical assessment at export@ide.es Special assemblies can be supplied in any combination, assembled and wired, with no minimum order quantity Proposal of sockets for Star boxes Schuko-TYPE FLUSH-fit SOCKETS IP44 FLUSH-FIT SOCKETS IP67 FLUSH-FIT SOCKETS REF. Poles I IP P+E 16A P+E 16A P+E 16A 67 REF. Poles I Voltage P+E 16A 200/250 V P+E 16A 380/415 V P+N+E 16A 200/415 V P+E 32A 200/250 V P+E 32A 380/415 V P+N+E 32A 200/415 V REF. Poles I Voltage P+E 16A 200/250 V P+E 16A 380/415 V P+N+E 16A 200/415 V P+E 32A 200/250 V P+E 32A 380/415 V P+N+E 32A 200/415 V ECO-STAR SYSTEM 5

6 ECOLOGY IP65 Distribution boxes IP65 Surface distribution boxes (ABS) CT3G 1x3 DIN rail 174x84x CT4G 1x4 DIN rail 174x101x CDN4PT 1x4 DIN rail 231x166x CDN6PT 1x6 DIN rail 231x202x CDN8PT 1x8 DIN rail 231x238x CDN12PT 1x12 DIN rail 246x310x CDN18PT 1x18 DIN rail 286x418x CDN24PT 2x12 (24) DIN rail 436x310x CDN36PT2F 2x18 (36) DIN rail 436x418x CDN36PT3F 3x12 (36) DIN rail 586x310x CDN54PT 3x18 (54) DIN rail 586x418x IP65 Surface distribution boxes (polycarbonate) CDP4PT 1x4 DIN rail 231x166x CDP6PT 1x6 DIN rail 231x202x CDP8PT 1x8 DIN rail 231x238x CDP12PT 1x12 DIN rail 246x310x CDP18PT 1x18 DIN rail 286x418x CDP24PT 2x12 (24) DIN rail 436x310x CDP36PT2F 2x18 (36) DIN rail 436x418x CDP36PT3F 3x12 (36) DIN rail 586x310x CDP54PT 3x18 (54) DIN rail 586x418x Ref. CDN: Frame and base in ABS RAL 7035 grey. Transparent PC tinted window, with UV protection. Ref. CDP: Frame and base in PC RAL 7035 grey. Transparent PC tinted window, with UV protection. IP65 - Surface - Sealables. 6 ECO-STAR SYSTEM

7 IP 65 IP65 Surface distribution boxes. With neutral and earth bars (ABS) CDN4PT/RR 1x4 DIN rail 231x166x CDN6PT/RR 1x6 DIN rail 231x202x CDN8PT/RR 1x8 DIN rail 231x238x CDN12PT/RR 1x12 DIN rail 246x310x CDN18PT/RR 1x18 DIN rail 286x418x CDN24PT/RR 2x12 (24) DIN rail 436x310x CDN36PT2F/RR 2x18 (36) DIN rail 436x418x CDN36PT3F/RR 3x12 (36) DIN rail 586x310x CDN54PT/RR 3x18 (54) DIN rail 586x418x IP65 Surface distribution boxes. With neutral and earth bars (Polycarbonate) CDP4PT/RR 1x4 DIN rail 231x166x CDP6PT/RR 1x6 DIN rail 231x202x CDP8PT/RR 1x8 DIN rail 231x238x CDP12PT/RR 1x12 DIN rail 246x310x CDP18PT/RR 1x18 DIN rail 286x418x CDP24PT/RR 2x12 (24) DIN rail 436x310x CDP36PT2F/RR 2x18 (36) DIN rail 436x418x CDP36PT3F/RR 3x12 (36) DIN rail 586x310x CDP54PT/RR 3x18 (54) DIN rail 586x418x Ref. CDN: Frame and base in ABS RAL 7035 grey. Transparent PC tinted window, with UV protection. Ref. CDP: Frame and base in PC RAL 7035 grey. Transparent PC tinted window, with UV protection. IP65 - Surface - Sealables. /RR: With neutral and earth bars. ECO-STAR SYSTEM 7

8 ECO-STAR System IP 65 Ecology Series (distribution boxes) + Star Series (Boxes for industrial sockets) The Eco-Star system gives the possibility of joining the IP65 watertight distribution boxes (Ecology series) and IP65 boxes for industrial sockets (Star series), to create large-sized assemblies and modular capacity. Combined with each other, they offer the installer the most versatile internationally-certified solution to combine distribution boxes and for power sockets. They have ample room for cables and extensive modular capacity. Intented for indoor and outdoor uses, wherever a high degree of protection and safety is required. Join system Joining these two models makes it possible to create large-sized power supply and distribution enclosures. The boxes have marks on the sides for the easy installation of M25 and M40 bushings with rubber gasket to guarantee IP65 protection. They can be joined both vertically and horizontally. The use of two M25 cable glands or a combination of an M25 cable gland and an M40 cable gland is recommended when more space is needed to run the cables. Ref : M25 BUSHING. Ref : M40 BUSHING. Different joining possibilities and combinations CDN24PT+CSN12PT CSN12PT+PCSNPLUS PCSN12PT+PCSN6PT Head Office. Leonardo da Vinci, 2. Pol. Ind. Los Huertos. E Zuera - Zaragoza (Spain) Telephone: ide@ide.es

ARGENTA INOX. IP66 Stainless steel wallmounting. ARGENTA INOX Technical Specifications (Stainless steel) ARGENTA INOX Certifications (Stainless steel)

ARGENTA INOX. IP66 Stainless steel wallmounting. ARGENTA INOX Technical Specifications (Stainless steel) ARGENTA INOX Certifications (Stainless steel) ARGENTA INOX IP66 Stainless steel wallmounting cabinets The ARGENTA Series is a group of steel enclosures used to house electrical or electronic switchgear, control gear and equipment necessary to supply,

More information

new new Industrial plugs and sockets

new new Industrial plugs and sockets Industrial plugs and sockets 213.1633 213.3236 221.1633 226.1636 New Optima series 16A-32A-63A-125A insulation voltage : 690V AC protection degree : IP44 and IP67 operating temperature : -25ºC to 40ºC

More information

ARGENTA ATEX For potentially explosive atmospheres. ARGENTA ATEX Technical Specifications Wall-mounting cabinets. ARGENTA ATEX Certifications

ARGENTA ATEX For potentially explosive atmospheres. ARGENTA ATEX Technical Specifications Wall-mounting cabinets. ARGENTA ATEX Certifications For potentially explosive atmospheres IDE presents its ATEX certified product range, specially intended for potentially explosive atmospheres, where the degree of protection and strength must be maximised.

More information

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards. 7% Plugs & sockets I Industrial plugs and sockets Scame I-1 5 Industrial switched sockets Scame I-4 6 Distribution boards Scame I-7 8 Industrial plug adaptors Scame I-8 Weatherproof switches and sockets

More information

IP65 INDUSTRIAL CABINETS

IP65 INDUSTRIAL CABINETS IP65 INDUSTRIAL CABINETS DISTRIBUTION BOX DISTRIBUTION BOX Page. 70 CONNECTING BOX COFFRET INDUSTRIELLE INDUBOX Page. 72 LINKABLE BOX COFFRET RACCORDEMENT Page. 73 WIRED CABINETS MONTÉ CÂBLÉ Page. 74 ACCESSORIES

More information

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

DEB71. Earth Leakage Monitoring Relay. Benefits. Description Earth Leakage Monitoring Relay Benefits Adjustable trip level. Adjustable leakage threshold from 30mA to 5A or from 300mA to 30A. 2 outputs. Two relay outputs provide, besides the alarm signal an additional

More information

ClimaSys Resistance heaters Selection guide

ClimaSys Resistance heaters Selection guide Selection guide Insulated resistance heaters Power W Voltage Type of connection Terminal block Cable 87504 10 12-36 DC X 87501 10 110-250 AC X 87512 21 12-36 DC X 87502 21 110-250 AC X 87518 55 12-36 DC

More information

SOLUZIONI PER ATMOSFERA ESPLOSIVA

SOLUZIONI PER ATMOSFERA ESPLOSIVA catalogo ATEX 2015 SOLUZIONI PER ATMOSFERA ESPLOSIVA ATEX catalogue book 2016 SOLUTIONS FOR EXPLOSIVE ATMOSPHERES Since 1904 In 1904 PALAZZOLI began its activity in Brescia when electrical energy was first

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required) FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries

More information

Eldon Product Overview

Eldon Product Overview Eldon Product Overview Product overview Floor Standing Enclosures page 4 Thermal Management page 32 Human Machine Interface page 26 Wall Mounted Enclosures page 12 Accessories page 38 Terminal Boxes page

More information

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24 INSTRUCTION MANUAL BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24 1/8 More information than that reported in this

More information

ATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES

ATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES ATEX catalogue book 20172018 SOLUTIONS FOR EXPLOSIVE ATMOSPHERES Since 1904 In 1904 PALAZZOLI began its activity in Brescia when electrical energy was first used in the industry. The Company is specialized

More information

CoreLine Waterproof the clear choice for LED

CoreLine Waterproof the clear choice for LED Lighting CoreLine Waterproof the clear choice for LED CoreLine Waterproof Whether for a new building or renovation of an existing space, customers want lighting solutions that provide quality of light

More information

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side s Frost detectors for use on the air side QAF63.2-J QAF63.6-J Active capillary tube sensor for acquiring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10

More information

Frost Protection Thermostat

Frost Protection Thermostat 1 203 Frost Protection Thermostat Electromechanical thermal reset limit thermostat RAK-TW.5..H RAK-TW.5..H.. Use Monitoring of frost protection temperature, with single-pole changeover microswitch Switching

More information

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side s Frost detector for use on the air side QAF64.2-J QAF64.6-J With active capillary tube sensing element for acquiring the lowest temperature within a range of 0 15 C With startup function Operating voltage

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products 1 821 1821P01 Frost sensors for use on the air side Active capillary tube sensor for measuring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10 V Use On

More information

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597 1 202 Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597 RAK-TW.1..H RAK-TW.1..H.. Use Function Changeover switch (S.P.D.T.) 2-position thermal reset limit thermostat with single-pole

More information

Libra - balance between comfort and lighting performance

Libra - balance between comfort and lighting performance ing Libra balance between comfort and lighting performance Libra The elegant Libra range has been specially designed for modern energyefficient compact fluorescent lamps. It combines highperformance optics

More information

40 CDe ENCLOSURES AND DISTRIBUTION BOARDS FOR SPECIFIC STANDARDS

40 CDe ENCLOSURES AND DISTRIBUTION BOARDS FOR SPECIFIC STANDARDS 40 CDe - Surface-mounting enclosures - Spanish standard Standard: IEC 60670-1; IEC 60670-24 Degree of protection: IP40 Installation temperature: max. +60 C; min. -25 C Impact : IK 08 Heat : thermo-pressure

More information

Output module (230 V)

Output module (230 V) Cerberus FIT Output module (30 V) FCA109-Z1 Output module for use in monitored output lines Output with potential-free relay contacts for controlling fire ventilators, air conditioning systems, elevators,

More information

PASSION FOR POWER. COMPANY PROFILE. More information at made in GERMANY. since 1931

PASSION FOR POWER. COMPANY PROFILE. More information at   made in GERMANY. since 1931 PASSION FOR POWER. COMPANY PROFILE More information at www.hensel-electric.de/en made in GERMANY since 1931 made in GERMANY since 1931 HENSEL - our passion is perfection Electrical power drives us forward.

More information

Ledinaire Batten Simply great LED

Ledinaire Batten Simply great LED Lighting Simply great LED The Ledinaire range contains a selection of popular off-the-shelf LED luminaires that comes with the high Philips quality levels at a competitive price. Reliable, energy efficient

More information

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE / 3 GM20 Digital Ground Continuity Relay For AC Systems Technical Bulletin NAE03230 / 0.20 GM20 Ground continuity monitor For AC systems Description The GM20 monitors the loop resistance of ground conductors

More information

Waterproof TCW060 just light

Waterproof TCW060 just light Lighting Waterproof TCW060 just light TCW060 Designed for use in demanding environments, TCW060 is an economical, compact waterproof luminaire. Dedicated versions are available for TL-D and TL5 lamps.ingressprotected

More information

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product

More information

TUNNELS BOXES AND CONNECTORS

TUNNELS BOXES AND CONNECTORS TUNNELS BOXES AND CONNECTORS MARECHAL ELECTRIC is now a leading company in the electric connection for tunnels. Based on technology specially intended for such difficult environments and quick light disconnection,

More information

KEYPADS. M.series 20 B1 M.series Axess 21 B2 S.series 22 B3 S.series Lite 23 B4 A.series 24 B5 ECO.series 25 B6 W.series 26 B7 KB.

KEYPADS. M.series 20 B1 M.series Axess 21 B2 S.series 22 B3 S.series Lite 23 B4 A.series 24 B5 ECO.series 25 B6 W.series 26 B7 KB. KEYPADS M.series 20 B1 M.series Axess 21 B2 S.series 22 B3 S.series Lite 23 B4 A.series 24 B5 ECO.series 25 B6 W.series 26 B7 KB.series 27 B8 M.series Thanks to a 30 year experience in the conception and

More information

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22 Hazardous Area Electrical Equipment Made TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22 Index Dimension Sheet Catalogue Information Leaflet Web Links TBSF/CBSF Information Page

More information

Ionisation single-tube smoke detector for duct mounting

Ionisation single-tube smoke detector for duct mounting Detectors Ionisation single-tube smoke detector for duct mounting 600 mm venturi tube is included., incl. end resistor (not RAC(M)) 9...33 V DC (via ABV control unit). 24 V AC ±15 % for RAC(M) models.

More information

CoreLine Wall-mounted the clear choice for LED

CoreLine Wall-mounted the clear choice for LED Lighting CoreLine Wall-mounted the clear choice for LED CoreLine Wall-mounted Whether for a new building or renovation of an existing space, customers want solutions that provide quality of light and substantial

More information

TUNNELS BOXES AND CONNECTORS

TUNNELS BOXES AND CONNECTORS TUNNELS BOXES AND CONNECTORS MARECHAL ELECTRIC is now a leading company in the electric connection for tunnels. Based on technology specially intended for such difficult environments and quick light disconnection,

More information

Operating Manual Distribution box

Operating Manual Distribution box Distribution box Operation manual Distribution box 27-5452-... Type 27-5452-... EN 1/12 EN 2/12 1. Product description The distribution boxes Type 27-5452-... are used for connections and distribution

More information

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.

More information

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.

More information

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,

More information

FDCL221-M Multi line separator module

FDCL221-M Multi line separator module FDCL221-M Multi line separator module addressable (FDnet/C-NET) Sinteso TM Cerberus PRO Automatic module with several line separators Creation of T taps (stub lines) in the FDnet/C-NET Operation of the

More information

Contents. External and internal tight cabinets, heating and cooling systems. IP55 outdoor distribution cabinets 1-4

Contents. External and internal tight cabinets, heating and cooling systems. IP55 outdoor distribution cabinets 1-4 The assembly of a modern and universal access system based on outdoor BKT Elektronik distribution cabinets is possible thanks to the application of cutting - edge solutions in compliance with Polish as

More information

DESIGN GUIDELINES. THERMAL building SOLUTIONS

DESIGN GUIDELINES. THERMAL building SOLUTIONS DESIGN GUIDELINES XL-Trace LSZH Self-Regulating Heating Cables for Pipe Freeze Protection Systems THERMAL building SOLUTIONS WWW.PENTAIRTHERMAL.COM Pipe Freeze protection system overview SBS Control Panel

More information

SmartForm top-class lighting in a fresh, appealing design

SmartForm top-class lighting in a fresh, appealing design Lighting SmartForm top-class lighting in a fresh, appealing design SmartForm LED BCS460 We all feel and perform better in a pleasant, comfortable working environment. Designed for use in offices, shops

More information

Ex LED light fittings

Ex LED light fittings About us TEP Ex is a regional leader in manufacturing of explosion-protected electrical equipment. Through continuous development of new products and markets, modernization of technology and investment

More information

LANDE SECURITY CABINETS and FIELD ENCLOSURES

LANDE SECURITY CABINETS and FIELD ENCLOSURES Front Door Type WxDxH Outer Skin Inner Skin Radius Type Corner Structure 90 Corner Structure Recessed Door Outer Closing Door Angled / Sloped Canopy Type Plain Canopy Type Crossfall Canopy Type Slotted

More information

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts. Ex d CCAC - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66 Stainless steel bolts Polyester coating External earth screw Grub screws for opening lid External earth screw

More information

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents) Residual current monitor RCM470LY/RCM475LY for TN and TT systems (AC and pulsating DC currents) TDB401003en/03.2010 Residual current monitor RCM470LY Residual current monitor for TN and TT systems (AC

More information

IT system floor-standing distribution

IT system floor-standing distribution IT system floor-standing distribution cabinet series -IPS-F/EDS for supplying power to medical locations in accordance with IEC 60364-7-710 and featuring a built-in insulation fault location system IT

More information

Loadstar AC/DC Systems

Loadstar AC/DC Systems WARRANTY W A R R A N T Y YEAR The Loadstar range of AC/DC central battery units comply with the latest relevant European and British standards. High quality, cost effective units provide secure sources

More information

SINGLE CHANNEL SYSTEM TWO CHANNEL SYSTEM

SINGLE CHANNEL SYSTEM TWO CHANNEL SYSTEM Series A14 GasSens - General Arrangement Diagrams SINGLE CHANNEL SYSTEM BATTERY BACK-UP (00-0057) (OPTIONAL) 4-20 ma OUTPUT (3) SPDT, 10A ALARM RELAYS (1) SPDT, 10A TROUBLE RELAY 2 COND, 20 AWG, 100' MAX.

More information

STORAGE ROLLER CABINETS & TOOL CHESTS...8 MODULES...12 FURNITURE SHOP...18 MAGNETIC ACCESSORIES...21 WORKSHOP TROLLEYS...22 METAL CHESTS...

STORAGE ROLLER CABINETS & TOOL CHESTS...8 MODULES...12 FURNITURE SHOP...18 MAGNETIC ACCESSORIES...21 WORKSHOP TROLLEYS...22 METAL CHESTS... ROLLER CABINETS & TOOL CHESTS...8 MODULES...12 FURNITURE SHOP...18 MAGNETIC ACCESSORIES...21 WORKSHOP TROLLEYS...22 METAL CHESTS...23 TOOL BOXES & SOFT STORAGE...23 MULTI-TOOL SETS...25 www.britoolexpert.co.uk

More information

THERMASREG TR 040 THERMASREG TR 060

THERMASREG TR 040 THERMASREG TR 060 THERMASREG TR 040 THERMASREG Temperature controllers, one-step, Mechanical temperature controllers wet room temperature controllers THERMASREG TR 040 with switching output and stainless steel capillary

More information

Halyester Totally insulated enclosure system. Degree of protection up to IP66. Product Aid. Multifunctional Enclosure Systems for all Environments

Halyester Totally insulated enclosure system. Degree of protection up to IP66. Product Aid. Multifunctional Enclosure Systems for all Environments Halyester Totally insulated enclosure system Product Aid Degree of protection up to IP66 Multifunctional Enclosure Systems for all Environments System Overview Eaton offers a wide range of multifunctional

More information

Welcome to Hager Presentation

Welcome to Hager Presentation Welcome to Hager Presentation Topics Intro to Hager Group Circuit Protection Enclosures Q&A IIEE Manila 4 th August 17 13.03.2009 2 Company presentation Who we are Hager Group is a leading provider of

More information

SPACE DETECTOR SP Presentation

SPACE DETECTOR SP Presentation SPACE DETECTOR SP2-114 Presentation 1 CONTENTS 2 ULTRASOUND DETECTION 4 2.1 PRINCIPLE 4 2.2 FOR A PERFECT WORKING ORDER 4 3 DETECTOR PLACEMENT 5 3.1 PLACEMENT SITUATION 6 3.2 ZONE OF DETECTION 6 3.3 CITY

More information

Enclosure Heaters and Fan Heaters

Enclosure Heaters and Fan Heaters Enclosure Heaters and Fan Heaters ISC carries innovative products for heating, cooling, temperature and humidity control of electronic enclosures. Our products are renowned for their reliability, long

More information

Cooling unit Mechanical control

Cooling unit Mechanical control ClimaSys CU Cooling unit Mechanical control Top-mounting models, ref. NSYCU760W2VR- NSYCU10W2VR- NSYCU1460W2VR J 26 A B 8 K 2 0 C D E H F G Cut-out template for top mounting without intermediate frame.

More information

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage LINETRAXX VME420 Multi-functional monitoring relay for undervoltage, overvoltage and frequency monitoring in AC/DC systems with separate supply voltage VME420_D00026_01_D_XXEN/06.2016 LINETRAXX VME420

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

SmartBalance Free Floor Standing. combining performance with smart design. Benefits. Features. Application. Specifications

SmartBalance Free Floor Standing. combining performance with smart design. Benefits. Features. Application. Specifications Lighting SmartBalance Free Floor Standing combining performance with smart design Free floor-standing luminaires are loved by customers as the ideal solution for personally controlled, flexible and comfortable

More information

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING TRA DITIONS AND INNOVATION Since 1922 The first LOVATO Electric headquartes founded in Bergamo in 1922: the starting point of the grand industrial

More information

LC1 Modular Ceiling Loudspeaker Range. en Installation note

LC1 Modular Ceiling Loudspeaker Range. en Installation note LC1 Modular Ceiling Loudspeaker en Installation note LC1 Modular Ceiling Loudspeaker Table of Contents en 3 Table of contents 1 System Overview 4 1.1 Housings 4 1.2 Loudspeakers 5 1.3 Accessories 6 2

More information

SPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents.

SPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents. Tender Specification Package #: Trace Heating Engineering Specification for Pipe Frost Protection Contents Y24 Trace heating 2 Appendix A Schematics & Drawings 8 Prepared by: Authorised by: Issued

More information

19 Cabinets. Eurolan. 19" Floor Standing Cabinets. Racknet Floor Standing Cabinets. Racklan Floor Standing Cabinets. Rackserv Floor Standing Cabinets

19 Cabinets. Eurolan. 19 Floor Standing Cabinets. Racknet Floor Standing Cabinets. Racklan Floor Standing Cabinets. Rackserv Floor Standing Cabinets Eurolan 19 Cabinets 118 19 Cabinets Eurolan 19" Floor Standing Cabinets page 120 Lamps page 190 Racknet Floor Standing Cabinets page 122 Racklan Floor Standing Cabinets page 127 Rackserv Floor Standing

More information

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation EVL-B Shock-resistant tempered glass - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation costs - Suitable for GAS category IIC LED

More information

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for HUALING

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for HUALING GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS Spare parts suitable for HUALING HUALING heating elements/thermostats heating elements heating elements for fryers 2 hole

More information

Masterseal Plus. IP66 Ingress Protected. Thrives in the Toughest Conditions.

Masterseal Plus. IP66 Ingress Protected. Thrives in the Toughest Conditions. Masterseal Plus Ingress Protected Thrives in the Toughest Conditions. p1 ULTIMATE PROTECTION For the Great Brtitish Weather MASTERSEAL PLUS RATED MK Electric has always been at the forefront of technical

More information

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH Page /3 SPECIFICATION SHEET Ed. Document UTE_ Issued Written Verified Approved MP36350 6-05-05 Strizzi Franco Page /3 INDICE HISTORY... 3 MODIFY RECORDING... 3 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

More information

Circuit Breaker with Residual Current Protection (CBR)

Circuit Breaker with Residual Current Protection (CBR) Circuit Breaker with Residual Current Protection (CBR) 3A-30mA-100mA-300mA-500mA- Safety and protection are the prime purposes of Terasaki products. You care about safety and protection. The users of products

More information

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional

More information

CMD420 / CMD421 Series

CMD420 / CMD421 Series 3 T M CMD420 / CMD421 Series Digital Current Relay (Overcurrent and Undercurrent) For Three-Phase AC Systems Technical Bulletin NAE1032810 / 06.2016 CMD420 / CMD421 Digital overcurrent and undercurrent

More information

Multi line separator module

Multi line separator module Sinteso Cerberus PRO Multi line separator module FDCL221-M Multi line separator module, addressed (FDnet/C-NET) Automatic module with several separate line separators Formation of stub lines (T-branches)

More information

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOGUE 2018 STEGO Catalogue 2018 Global presence in Thermal Management This catalogue contains the full range of STEGO products for protection of electronic

More information

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10.

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10. 2 Device technology XS/S 1.1 2CDC 071 115 F0008 The Interface XS/S 1.1 integrates the Intrusion Alarm Panel L240 into the KNX intelligent installation system. It is connected to the XIB bus of the Intrusion

More information

performance PowerBalance, surface mounted Benefits Features Application Specifications

performance PowerBalance, surface mounted Benefits Features Application Specifications Lighting PowerBalance surfacemounted sustainable performance PowerBalance, surface mounted When it comes to lighting an office space with LED luminaires, people are usually willing to invest in sustainability

More information

ATM Lighting sp. z o.o

ATM Lighting sp. z o.o INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL210LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,

More information

Input module, input/output modules

Input module, input/output modules Sinteso / Cerberus PRO Input module, input/output modules FDCI222, FDCIO222, FDCIO224 Input module and input/output modules for the automatically addressed detector line Input module FDCI222: Four monitored

More information

Gram Commercial Technical information

Gram Commercial Technical information 1 Exploded view BioCompact RR 210 2 Exploded view BioCompact IIRR 210 3 Interior equipment Alu drawers: Wire shelves: Perforated shelves: 4 Wire drawers: Wire baskets: Plastic drawer: 5 Fan suspension

More information

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket

More information

Spare parts list ( ) Spare parts list PUZZI 100

Spare parts list ( ) Spare parts list PUZZI 100 Spare parts list (5.958-029.0) Spare parts list PUZZI 100 10.02.2012 www.kaercher.com EN Table of contents Spare parts list PUZZI 100 (5.958-029.0)... 6 10 Tank water PUZZI 100 (0.162-640.0)... 7 20 Appliance

More information

XEON. High impact resistant body and PC cover. Double layer coating. through wiring. Build-in microwave sensor.

XEON. High impact resistant body and PC cover. Double layer coating. through wiring. Build-in microwave sensor. XEON is a rectangular shape wall or ceiling fixture. This luminaire family has a robust aluminium construction housing with a high impact resistant polycarbonate diffuser. It is to be operated with LED

More information

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry LINETRAXX VMD420 Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry VMD420_D00137_02_D_XXEN/06.2016 LINETRAXX VMD420 Multi-functional

More information

Preface. This guide proposes a procedure for assembling the Prisma Plus System G.

Preface. This guide proposes a procedure for assembling the Prisma Plus System G. Preface This guide proposes a procedure for assembling the Prisma Plus System G. We have designed it to help you successfully complete your first projects. It ensures that assembling and cabling staff,

More information

The Right Temperature, Always THS Series Modular Thermostats

The Right Temperature, Always THS Series Modular Thermostats The Right Temperature, Always THS Series Modular Thermostats Optimizing Control From ABB, a solution for precise and effective heat regulation The THS series modular thermostats manufactured by ABB meet

More information

Affordable and reliable energy saving LED Lighting Luminaires

Affordable and reliable energy saving LED Lighting Luminaires Lighting Affordable and reliable energy saving LED Lighting Luminaires Smartbright Waterproof G2 SmartBright Waterproof G2 is an innovation from SmartBright Waterproof G1, can be used to replace traditional

More information

Monitoring Devices 11/1

Monitoring Devices 11/1 11/4 Introduction 11/6 5TE5 8 light indicators 11/7 4AC3 0, 4AC3 1 bells, buzzers 11/7 5TT3 46 fault signaling units 11/8 7LQ2 1, 5TT3 3 dusk switches 11/9 7LQ2 0 temperature controllers 11/9 5TT3 170

More information

On the job around the clock 24/7: Fire detection systems

On the job around the clock 24/7: Fire detection systems On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,

More information

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P 1 of 13 These instructions should be read by: The specifying engineer. The installation engineer. The user. The service engineer. WARNINGS Failure

More information

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV FILTER FANS SERIES LV ROOF MOUNTED FAN For the ventilation of control cabinets, enclosures and housings Different filter mats for dust collection LV series offers low shape and quick mounting EMC versions

More information

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature 1 858 1858P01 1858P02 1859P02 Symaro Room Sensors for relative humidity (high accuracy) and temperature AQF3150 QFA31 Use Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 4 20 ma for r h and

More information

SmartForm the new standard for office lighting with modular recessed luminaires

SmartForm the new standard for office lighting with modular recessed luminaires Lighting SmartForm the new standard for office lighting with modular recessed luminaires SmartForm TBS462 Reflecting Philips drive for simplicity and sustainability, SmartForm recessed is a complete family

More information

StoreFlux powerful LED accent lighting that blends perfectly in the store architecture

StoreFlux powerful LED accent lighting that blends perfectly in the store architecture Lighting StoreFlux powerful LED accent lighting that blends perfectly in the store architecture The StoreFlux gridlight can be equipped with up to four LED modules with a special reflector system to deliver

More information

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW 1 212 Double thermostat Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW RAZ-TW... 2-position control thermostat and thermal reset limit thermostat with singlepole

More information

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 505 Grünberg Tel.: 00 807-0 Fax: 00 807-259 Insulation monitoring device for unearthed AC/DC systems (IT systems for the supply of operating theatre

More information

P126FTT Fiber Transfer Terminal

P126FTT Fiber Transfer Terminal PRIMEX P126FTT Fiber Transfer Terminal The P126FTT Fiber Transfer Terminal allows the construction/splice crew to connect fiber during initial deployment without needing to return to the site. The service

More information

for relative humidity and temperature

for relative humidity and temperature 1 861 1861P01 Duct sensor for relative humidity and temperature QFM65 Operating voltage AC 24 V Signal output DC 0...10 V for relative humidity and temperature Measurement accuracy ±3 % r. h. within the

More information

SmartForm the new standard for office lighting with slender recessed luminaires

SmartForm the new standard for office lighting with slender recessed luminaires Lighting SmartForm the new standard for office lighting with slender recessed luminaires Reflecting Philips drive for simplicity and sustainability, SmartForm recessed is a complete family of highly versatile

More information

Interface and EOL Modules 8

Interface and EOL Modules 8 Interface and EOL Modules Interface Modules Series 420 25 Interface Modules Series 100 291 EOL Modules 293 254 Interface and EOL Modules Interface Modules Series 420 Interface Modules Serie 420 Interface

More information

HEATING. Anticondensation Heaters

HEATING. Anticondensation Heaters HEATING Anticondensation Heaters Application Enclosure heaters are often necessary to prevent failures or corrosion caused by low temperatures or high humidity inside the enclosure. Such conditions are

More information

TECHNICAL SHEET. About the product

TECHNICAL SHEET. About the product No. 533/ 07.01.2015, Edition No. 9, 1/5 Outdoor decorative luminaire SYSTEM WITH AVIS- 02-9W LED / AVIS-02M-9W LED SYSTEM WITH AVIS-02-9W LED SYSTEM WITH AVIS-02-9W LED + POWER SUPPLY CONNECTION About

More information

Input module, input/output module

Input module, input/output module Sinteso / Cerberus PRO Input module, input/output module FDCI221, FDCIO221 Input module and input/output module for the automatically addressed detector line Input module FDCI221: Monitorable contact input

More information