40 CDe ENCLOSURES AND DISTRIBUTION BOARDS FOR SPECIFIC STANDARDS

Size: px
Start display at page:

Download "40 CDe ENCLOSURES AND DISTRIBUTION BOARDS FOR SPECIFIC STANDARDS"

Transcription

1 40 CDe - Surface-mounting enclosures - Spanish standard Standard: IEC ; IEC Degree of protection: IP40 Installation temperature: max. +60 C; min. -25 C Impact : IK 08 Heat : thermo-pressure with ball 70 C Resistance to abnormal heat and fire: Glow wire test 650 C Complete double insulation, in accordance with EN Standard, obtainable with screwcaps (GW or GW ) or resin fixing brackets (GW ). SURFACE-MOUNTING ENCLOSURES WITHOUT DOOR - IP40 1

2 40 CDe - Flush-mounting enclosures - Spanish standard Standard: IEC ; IEC Degree of protection: IP40 Installation temperature: max. +60 C; min. -15 C Impact : IK 07 Heat : thermo-pressure with ball 70 C Resistance to abnormal heat and fire: Glow wire test 650 C Complete double insulation, in accordance with EN Standard. SURFACE-MOUNTING ENCLOSURES WITHOUT DOOR - IP40 4+8M GW M GW SURFACE-MOUNTING ENCLOSURES WITHOUT DOOR - IP40 4+8M GW GW M GW GW

3 40 CDe - Surface-mounting enclosures and boards - German standard Standard: IEC ; IEC ; DIN VDE Degree of protection: IP65 Installation temperature: max. +60 C; min. -25 C Impact : IK 07 Heat : thermo-pressure with ball 70 C Resistance to abnormal heat and fire: Glow wire test 750 C Complete double insulation, in accordance with EN Standard, obtainable with screwcaps (GW or GW ) or resin fixing brackets (GW ). ENCLOSURES WITH SMOKED TRANSPARENT DOOR - IP65 Diameter of flange ducts M16 M20 M25 M32 12M Modular assembly Fixing C B E F G H D D max E F NR I L GW GW / M GW GW M GW GW

4 40 CDe - Flush-mounting enclosures - German standard Standard: IEC ; IEC ; DIN VDE ; DIN Degree of protection: IP40 Installation temperature: max. +60 C; min. -15 C Impact : IK 07 Heat : thermo-pressure with ball 70 C Resistance to abnormal heat and fire: Glow wire test 650 /850 C Complete double insulation, in accordance with EN Standard. ENCLOSURES FOR MASONRY OR PLASTERBOARD WALLS - BLANK DOOR AND METAL FRAME - IP40 12M Modular assembly Fixing C N D E F G H D I L M GW GW M 36M 48M GW GW GW GW GW GW

5 40 CDe - Modular surface-mounting enclosures - French standard Standard: IEC ; IEC ; NF C Degree of protection: IP30/40 Installation temperature: max. +60 C; min. -25 C Impact : IK 07 Heat : thermo-pressure with ball 70 C Resistance to abnormal heat and fire: Glow wire test 750 C Complete double insulation, in accordance with EN Standard, obtainable with screwcaps (GW or GW ) or resin fixing brackets (GW ). ENCLOSURES WITHOUT DOOR - IP30 Fixing 13M GW M GW M GW M GW SUPPORTING BASES WITHOUT DOOR FOR THE EDF CONNECTION ONE-WAY SWITCH - LEADABLE SUPPORTING BASES WITHOUT DOOR FOR THE EDF CONNECTION ONE-WAY SWITCH AND THE SINGLE-PHASE ELECTRONIC METER - LEADABLE GW GW GW GW

6 CONTAINER FOR CABLE SERVICES (T.R.I.) - IP40 MODULAR ENCLOSURE FINISHING DOOR - FRENCH STANDARD MODULAR ENCLOSURE FINISHING DOOR - FRENCH STANDARD BACK-MOUNTING BOX AND BLANK METAL DOOR FOR FLUSH-MOUNTING INSTALLATIONS A 13M M M M 600 KIT OF MODULAR SPACERS FOR ENCLOSURES, BASES, CONTAINERS AND SUBSCRIBER BOARDS Fixing 13M GW M GW M GW M GW BACK- MOUNTING BOX Solid door Fixing GW GW GW GW GW GW GW GW

7 40 CDe - Surface-mounting enclosures - British standard Standard: BS EN ; BS EN Degree of protection: IP30 Installation temperature: max. +60 C; min. -25 C Impact : IK 05 Heat : thermo-pressure with ball 70 C Resistance to abnormal heat and fire: Glow wire test 650 C Complete double insulation, in accordance with EN Standard, obtainable with screwcaps (GW or GW ) or resin fixing brackets (GW ). ENCLOSURES SUITABLE FOR HOUSING TERMINAL BLOCKS AND COMB FOR CONNECTING MODULAR DEVICES Fixing Input types 25 x x x 30 4M GW M GW M GW M GW M GW

8 Installation of the Consumer Units The Consumer Units of the 40 CDe range must be installed by skilled personnel in compliance with their intended use and with the Standards and laws in force (including IEE standards related to wiring). The Consumer Units are designed for indoor use and may be installed at an altitude no higher than 2,000 metres, in a clean, dry environment with a temperature between -5 C and 40 C. In the event of the side-by-side installation of several one-way switches, we recommended that such one-way switches are not used continuously at their rated power for more than one hour. You are advised to apply a use factor equal to about 70% in the event of continuous use. The total output load must not exceed the rated current of the Consumer Unit. 40 CDe - Shells for Consumer Units Product 40CDe Standard BS EN BS EN Type of installation Surfacemounting TECHNICAL DATA AND REFERENCE STANDARDS Degree of protection Impact Protection against indirect contacts Installation temperature min. ( C) max. ( C) Heat Thermo-pressure with ball ( C) Resistance to abnormal heat and fire Glow wire test ( C) IP30 IK MT60 - Miniature circuit breakers Product MT60 Standard EN EN Insulation voltage Ui (V) TECHNICAL DATA AND REFERENCE STANDARDS frequency (Hz) breaking capacity (ka) 6 10 Tripping characteristic current In (A) No. poles No. poles per module EN temperature ( C) B P 1 30 Product MT 60 CAPACITY OF TERMINALS AND INSTALLABLE SECTIONS Capacity of terminals No. x (mm 2 ) Connectable section (mm 2 ) Rigid cables Flexible cables Double connection Triple connection Max 1x35-2x16-3x10 Min. 1 x 1 Max 1x25-2x10-3x6 Min. 1 x Switch disconnectors Non-automatic circuit breaker with quick and simultaneous pole opening device. Product Residual current circuit breaker Standard Category of use TECHNICAL DATA AND REFERENCE STANDARDS No. modules EN Insulation voltage (V) 2P EN AC Residual current circuit breakers 2P 25-80A Standard EN EN EN No. modules EN No. poles voltage (V) operating current (A) Two-pole and four-pole RCCBs without current surge release, monobloc and free tripping. Available in AC class (for sine-wave alternating residual current only) in the instantaneous version. e: (1) the data item in brackets refers to rigid conductors. Capacity of terminals min (mm 2 ) TECHNICAL DATA AND REFERENCE STANDARDS residual current (ma) max (mm 2 ) Degree of protection Front Rear IP XXD IP XXB Breaking capacity and residual current circuit breaker closure Capacity of terminals Degree of protection IΔm (A) IΔc (ka) 2 2P min (mm 2 ) Max (1) (mm 2 ) 25 (35) Front IP20 Rear IP40 8

Welcome to Hager Presentation

Welcome to Hager Presentation Welcome to Hager Presentation Topics Intro to Hager Group Circuit Protection Enclosures Q&A IIEE Manila 4 th August 17 13.03.2009 2 Company presentation Who we are Hager Group is a leading provider of

More information

Residual Current Devices

Residual Current Devices Residual devices F200 Series UL 1053 Residual devices F200 Series Residual Current Devices Description The F200 Series residual devices offer a wide range of product for all of your fault protection needs.

More information

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE FINAL DISTRIBUTION PRODUCTS RANGE ISO 14001:2004 Certified ISO 9001:2008 Certified FUSES INDIA LTD Lawson Fuses India Ltd is a wholly owned subsidiary of Lawson Fuses Ltd,a long established UK company

More information

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product

More information

TECHNICAL DATA AND REFERENCE STANDARDS. Essential electrical data* Resistance at test voltage (V) Insulation resistance (MΩ)

TECHNICAL DATA AND REFERENCE STANDARDS. Essential electrical data* Resistance at test voltage (V) Insulation resistance (MΩ) General characteristics Modular range of devices for domestic and similar uses on frames for flush-mounting boxes of up to 8 modules. It includes controls, socket-outlets, protections, indicators, connectors

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Product Test Centre 15 Progress Road Eastwood Leigh-on-Sea Essex SS9 5JA Contact: Mr S Bailey Tel: +44 (0)1702 425738 E-Mail: stuart.bailey@honeywell.com

More information

Independent, accredited testing station Member laboratory of STL and LOVAG

Independent, accredited testing station Member laboratory of STL and LOVAG Independent, accredited testing station Member laboratory of STL and LOVAG TYPE TEST REPORT NO. 3096.2081034.859 GSAB Elektrotechnik GmbH Lindenstraße 23 99718 Greußen GERMANY GSAB Elektrotechnik GmbH

More information

new new Industrial plugs and sockets

new new Industrial plugs and sockets Industrial plugs and sockets 213.1633 213.3236 221.1633 226.1636 New Optima series 16A-32A-63A-125A insulation voltage : 690V AC protection degree : IP44 and IP67 operating temperature : -25ºC to 40ºC

More information

QA(13) - Series Miniature Circuit Breakers

QA(13) - Series Miniature Circuit Breakers 1 pole 2 pole 3 pole 3 + N Features AC Circuit Breaker Hydraulic-Magnetic technology 100% rating capability, independent of ambient temperature VC 8036 compliant (SANS 556-1) VDE approved, CE certified

More information

3. RCCB (residual current operated circuit-breaker without integral overcurrent protection)

3. RCCB (residual current operated circuit-breaker without integral overcurrent protection) RESIDUAL CURRENT DEVICE (RCD) - Contents 1. Introduction 2. General 3. RCCB (residual current operated circuit-breaker without integral overcurrent 4. RCBO (residual current operated circuit-breaker with

More information

Consumer Units for Domestic Household (and other) Premises. Amendment No. 3 BS 7671

Consumer Units for Domestic Household (and other) Premises. Amendment No. 3 BS 7671 Consumer Units for Domestic Household (and other) Premises Amendment No. 3 BS 7671 ALL METAL CONSUMER UNITS FOR USE IN DOMESTIC HOUSEHOLD PREMISES 17th Edition Wiring Regulations Incorporating Amendment

More information

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24 INSTRUCTION MANUAL BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24 1/8 More information than that reported in this

More information

Operating Instructions. For. Alarm Control Module. Model SSR 500

Operating Instructions. For. Alarm Control Module. Model SSR 500 SSR 500 LEVEL CONTROL RELAY MODULE Operating Instructions For Alarm Control Module Model SSR 500 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions

More information

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards. 7% Plugs & sockets I Industrial plugs and sockets Scame I-1 5 Industrial switched sockets Scame I-4 6 Distribution boards Scame I-7 8 Industrial plug adaptors Scame I-8 Weatherproof switches and sockets

More information

+ = ECO-STAR System. Ecology Series (Distribution boxes) + Star Series (Boxes for industrial sockets) ECOLOGY Technical Specifications

+ = ECO-STAR System. Ecology Series (Distribution boxes) + Star Series (Boxes for industrial sockets) ECOLOGY Technical Specifications + = ECO-STAR System Ecology Series (Distribution boxes) + Star Series (Boxes for industrial sockets) STAR Technical Specifications - Degree of protection: IP65. - Resistance to impact: IK08. - Glow wire

More information

Ackrediteringens omfattning / Scope of accreditation Components and installation

Ackrediteringens omfattning / Scope of accreditation Components and installation Standard designation Mini-Couplers for the interconnection of electrical mains supplied equipment in road vehicles Flat non-wirable two-pole plugs 2,5A 250V for class II-equipment Conversion adapters for

More information

Monitoring Devices 11/1

Monitoring Devices 11/1 11/4 Introduction 11/6 5TE5 8 light indicators 11/7 4AC3 0, 4AC3 1 bells, buzzers 11/7 5TT3 46 fault signaling units 11/8 7LQ2 1, 5TT3 3 dusk switches 11/9 7LQ2 0 temperature controllers 11/9 5TT3 170

More information

Operation and use. Functions and characteristics

Operation and use. Functions and characteristics Operation and use Function Vigirex relays measure the earth-leakage current in an electrical installation via their associated toroids. Vigirex relays may be used for: b residual-current protection (RH10,

More information

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Phone: 040 807-0 Fax: 040 807-259 Alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC display

More information

CAESAREA SUBSTATION BATTERY ENERGY STORAGE SYSTEM PREFABRICATED EQUIPMENT CONTAINER SPECIFICATION ATTACHMENT TO ANNEXURE "B"

CAESAREA SUBSTATION BATTERY ENERGY STORAGE SYSTEM PREFABRICATED EQUIPMENT CONTAINER SPECIFICATION ATTACHMENT TO ANNEXURE B CAESAREA SUBSTATION BATTERY ENERGY STORAGE SYSTEM PREFABRICATED EQUIPMENT CONTAINER SPECIFICATION ATTACHMENT TO ANNEXURE "B" DATE DRAWER DESIGNER APPROVER This document shall be revised in its entirety

More information

LC2200 Level Controller Installation and Maintenance Instructions

LC2200 Level Controller Installation and Maintenance Instructions 4025250/9 IM-P402-77 AB Issue 9 LC2200 Level Controller Installation and Maintenance Instructions LC2200 ALARM TEST >50% >100%

More information

Remote alarm indicator and test combination MK2430

Remote alarm indicator and test combination MK2430 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Tel.: 040 807-0 Fax: 040 807-259 Remote alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC

More information

Contents. External and internal tight cabinets, heating and cooling systems. IP55 outdoor distribution cabinets 1-4

Contents. External and internal tight cabinets, heating and cooling systems. IP55 outdoor distribution cabinets 1-4 The assembly of a modern and universal access system based on outdoor BKT Elektronik distribution cabinets is possible thanks to the application of cutting - edge solutions in compliance with Polish as

More information

The complete residential solution

The complete residential solution The complete residential solution Circuit Protection Resi MAX Clipsal.com/ResidentialProtection Contents What s new in final distribution residential...3 Resi MAX gives you the entire solution...4 Essential

More information

GENERAL SPECIFICATION ELECTRICAL

GENERAL SPECIFICATION ELECTRICAL GENERAL SPECIFICATION ELECTRICAL GS ELE 331 Tape trace heating 00 10/04 First issue Rev. Date Notes Contents 1. Scope...3 2. Reference documents...3 3. Environmental Conditions...4 4. Technical Requirements...5

More information

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame Product Selection 225 A, I-Frame Assembled 225 A I-Frame Interrupting Rating/Breaking Capacity Thermal-Magnetic Circuit Breakers Interrupting Rating (50/60 Hz), UL 489/CSA C22.2-5, No. 5-02 [ka] Thermal-Magnetic,

More information

18/2 General. 18/4 Dimensional Drawings N. 18/7 Switches and Pushbuttons. 18/14 Socket Outlets. 18/16 Dimmers. 18/31 Motion Detectors

18/2 General. 18/4 Dimensional Drawings N. 18/7 Switches and Pushbuttons. 18/14 Socket Outlets. 18/16 Dimmers. 18/31 Motion Detectors Siemens AG 00 8 8/ General 8/ Dimensional Drawings 8/7 Switches and Pushbuttons 8/ Socket Outlets 8/6 Dimmers 8/ Motion Detectors 8/6 Shutter/Blind Controls 8/60 Room Temperature Controllers 8/6 Communication

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...: Test Report issued under the responsibility of: TEST REORT IEC 61008-1 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) art 1: General

More information

Polymer solutions Heating mat EM2-CM

Polymer solutions Heating mat EM2-CM 1.5 Polymer solutions 1. Application EM2-CM is a constant wattage heating mat for simple, fast, and effective ramp and accessway heating to prevent snow and ice formation. The EM2-CM mat is particularly

More information

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply   - Tel: Systems Index Systems - Systems Systems...1 -.16 General information Description...1 System description...2 Overview...3 Ordering details Arc monitor with detectors...4 Current sensing unit...5 Technical

More information

TUNNELS BOXES AND CONNECTORS

TUNNELS BOXES AND CONNECTORS TUNNELS BOXES AND CONNECTORS MARECHAL ELECTRIC is now a leading company in the electric connection for tunnels. Based on technology specially intended for such difficult environments and quick light disconnection,

More information

Integrated Solutions Low Voltage Systems

Integrated Solutions Low Voltage Systems Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx

More information

Overload relays. General descriptions. Configuration of the front

Overload relays. General descriptions. Configuration of the front Overload relays General descriptions Type MT, bimetal-style, overload relays are designed to protect AC circuits and motors against overloads, phase failure, long starting times and prolonged stalling

More information

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10 PRODUCT INFORMATION PI 38.43 Sounder SG 200 Page 1 of 10 Table of Contents 1. Product Description............................... 3 2. Features......................................... 3 3. Functional Description............................

More information

Explosion Protected Panelboards D2Z Series

Explosion Protected Panelboards D2Z Series Eplosion Protected Panelboards D2Z Series Installation & Maintenance Information IF 1416 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE APPLICATION The D2Z Series panelboards provide a centrally controlled

More information

DESIGN GUIDELINES. THERMAL building SOLUTIONS

DESIGN GUIDELINES. THERMAL building SOLUTIONS DESIGN GUIDELINES XL-Trace LSZH Self-Regulating Heating Cables for Pipe Freeze Protection Systems THERMAL building SOLUTIONS WWW.PENTAIRTHERMAL.COM Pipe Freeze protection system overview SBS Control Panel

More information

Bulletin 1608N MiniDySC Dynamic Sag Corrector

Bulletin 1608N MiniDySC Dynamic Sag Corrector User Manual Bulletin 1608N MiniDySC Dynamic Sag Corrector Single Phase Voltage Sag Correction 2...6 Amps (250...750 VA) Important User Information Solid-state equipment has operational characteristics

More information

TUNNELS BOXES AND CONNECTORS

TUNNELS BOXES AND CONNECTORS TUNNELS BOXES AND CONNECTORS MARECHAL ELECTRIC is now a leading company in the electric connection for tunnels. Based on technology specially intended for such difficult environments and quick light disconnection,

More information

Lyovapor L-300 Technical data sheet

Lyovapor L-300 Technical data sheet Lyovapor L-300 Technical data sheet With Infinite-Technology the Lyovapor L-300 offers continuous sublimation for the first time with two alternate working and automatically hygienically cleaned condensers

More information

LC3000 Level Controller Installation and Maintenance Instructions

LC3000 Level Controller Installation and Maintenance Instructions 4025550/12 IM-P402-36 AB Issue 12 LC3000 Level Controller Installation and Maintenance Instructions 1. General safety information LC3000 NORM ALARM TEST 2. General product information 3. Installation 4.

More information

DIN /DIN Aseptic Flange Union for ISO 1127 Schedule Pipe

DIN /DIN Aseptic Flange Union for ISO 1127 Schedule Pipe / Aseptic Flange Union for ISO 1127 Schedule Pipe DIN 11864 2/ Aseptic Flange Union This range of aseptic fittings has been developed by the German hygienic industry to meet the exacting needs of the food,

More information

Major Fault Caused by Stator Winding Circuit Ring Failure

Major Fault Caused by Stator Winding Circuit Ring Failure Case study Major Fault Caused by Stator Winding Circuit Ring Failure Joël Pedneault-Desroches, P. Eng. Presentation Outline Introduction Inspection report Chronology of events Repair Conclusion 2 Introduction

More information

Project planning (original) EN. Functional safety. Inverter i550-cabinet kw

Project planning (original) EN. Functional safety. Inverter i550-cabinet kw Project planning (original) EN Functional safety Inverter i550-cabinet 0.25... 45 kw This page intentionally left blank! Contents Contents Safety instructions 4 Basic safety measures 4 Residual hazards

More information

LC1 Modular Ceiling Loudspeaker Range. en Installation note

LC1 Modular Ceiling Loudspeaker Range. en Installation note LC1 Modular Ceiling Loudspeaker en Installation note LC1 Modular Ceiling Loudspeaker Table of Contents en 3 Table of contents 1 System Overview 4 1.1 Housings 4 1.2 Loudspeakers 5 1.3 Accessories 6 2

More information

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module FIRE ALARM CONTROL EQUIPMENT Addendum October 2006 Instructions for new style EN54-4 Power supply unit module MXLK-05 Issue 2.0 June 2007 INSTALLATION Safety Suppliers of articles for use at work are required

More information

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation mfh systems modern floor heating AirUnit Decentralised domestic ventilation Installation instructions List of contents, Installation instructions Page 1. General information... 03 2. Function / planning

More information

47LV BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL DC INPUT DIGITAL PANEL METER MODEL. (4 1/2 digit, LED display type)

47LV BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL DC INPUT DIGITAL PANEL METER MODEL. (4 1/2 digit, LED display type) INSTRUCTION MANUAL DC DIGITAL PANEL METER ( / digit, LED display type) MODEL LV BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined

More information

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller 4025250/10 IM-P402-77 AB Issue 10 LC2200 Level Controller Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Setting up the controller 5.

More information

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

SMHA Hatch High temperature fan HT-fan Installation and Maintenance High temperature fan HT-fan Installation and Maintenance 22.8.2012 Contents 1. Important information 2. Safety notes 3. Technical description 4. Transport 5. Mounting instructions 6. Commissioning 7. Maintenance

More information

* Consult factory on conditions for approval acceptability

* Consult factory on conditions for approval acceptability 6 Introduction Guide Guide to Power Protection How various power protection devices work How to use power protection devices 39 6600 Series Sub-miniature bimetal thermostat 8-PIN DIP package configuration

More information

TECHNICAL DATA SHEET. FreeSpace DS 16F 1 OF 8. Loudspeaker. Product Overview. Product Information. Key Features. Applications

TECHNICAL DATA SHEET. FreeSpace DS 16F 1 OF 8. Loudspeaker. Product Overview. Product Information. Key Features. Applications Product Overview The Bose FreeSpace DS 16F loudspeaker is a highperformance, flush-mount loudspeaker designed for background music and speech reproduction in a wide range of commercial applications, including

More information

LoadCentre KQ Distribution boards

LoadCentre KQ Distribution boards > LoadCentre KQ Distribution boards 4 LoadCentre KQ - single phase A distribution boards - 125A Single phase A distribution boards - 125A Manufactured and tested to BS EN 61439-3 Maximum busbar 125A Voltage

More information

RD3 and RCQ020 Electronic low-voltage residual current devices for miniature and moulded-case circuit-breakers

RD3 and RCQ020 Electronic low-voltage residual current devices for miniature and moulded-case circuit-breakers RD3 and RCQ020 Electronic low-voltage residual current devices for miniature and moulded-case circuit-breakers 2CSC444001B0201 RD3 and RCQ020 A unique and complete range for residual current protection

More information

Smoke Fire Damper Interface (230V)

Smoke Fire Damper Interface (230V) Always READ this document BEFORE INSTALLATION. Please Retain for future reference. This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product

More information

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions Fan-and-filter units Features Fan-and-filter units are ideal for dissipating heat loads costeffectively. The pre-requisite is that the ambient air must be relatively clean and with a temperature below

More information

HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT

HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT Product Overview The HF9101-V1 is an electronic thermostat designed to give energy-efficient frost protection to pipe work where thermal insulation alone cannot protect pipes from freezing or being damaged

More information

PureLine D. Technical Specification

PureLine D. Technical Specification ... Complete Range Model Maximum Disinfection Maximum Disinfection Min. Flange Approx Weight (kg) Capacity * (m 3 /hr) Capacity ** (m 3 /hr) T 10 Size Chamber Power Power 26mJ/cm 2 RED 120mJ/cm 2 RED (%)

More information

Arc Fault Detection Devices. 18th Edition - We re ready

Arc Fault Detection Devices. 18th Edition - We re ready Arc Fault Detection Devices 18th Edition - We re ready ARC FAuLT DETECTION DEvICES & THE WIRING REGuLATIONS The 18th edition wiring regulations (BS7671) sets out requirements for electrical installations

More information

Annex "Connection systems" to the manufacturer's declaration no /06/E

Annex Connection systems to the manufacturer's declaration no /06/E Product group: terminal blocks Feed through terminal blocks EN 60947-7-1:1991 DIN VDE 0611-1:1992-08 IEC 60947-7-1:1989 -screw -insulation displacement (IDC) EN 60998-2-3:1993 DIN VDE 0613-2-3:1994-09

More information

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold RADIANT PANELS TRENCH PERIMETER GRILLES ELEMENTS PIPER FARM, BROMLEY GREEN ROAD, ASHFORD, KENT. TN26 2EF TEL: 01233 733308 FAX: 01233 733883 E-MAIL: sales@feukltd.com RADIANT PANEL RANGE INTRODUCTION HOW

More information

Kickspot Self-testing/AutoDiag self-contained emergency lighting unit

Kickspot Self-testing/AutoDiag self-contained emergency lighting unit CONTENTS Page 1. Description.............................1 2. Installation.............................2 3. Connection.............................4 4. Use......................................8 5. Maintenance...........................9

More information

Interface and EOL Modules 8

Interface and EOL Modules 8 Interface and EOL Modules Interface Modules Series 420 25 Interface Modules Series 100 291 EOL Modules 293 254 Interface and EOL Modules Interface Modules Series 420 Interface Modules Serie 420 Interface

More information

FM MEDICOL. Cableflow International Limited. The FLUSH MEDICOL (FM) Patient Care Services. Column has evolved from a market requirement for a

FM MEDICOL. Cableflow International Limited. The FLUSH MEDICOL (FM) Patient Care Services. Column has evolved from a market requirement for a Cableflow International Limited TM FM MEDICOL The FLUSH MEDICOL (FM) Patient Care Services Column has evolved from a market requirement for a stylish adaptable vertical trunking system which can be wall

More information

Guide to: 17 th Edition Consumer Units

Guide to: 17 th Edition Consumer Units Guide to: 17 th Edition Consumer Units Introduction For well over one hundred years the Wiring Regulations have provided the rules which must be followed to make sure that electrical installations are

More information

15KW ELECTRIC FAN HEATER

15KW ELECTRIC FAN HEATER 15KW ELECTRIC FAN HEATER MODEL NO: DEVIL 7015 PART NO: 6935456 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product,

More information

VAMP 120 & 121. Arc flash detection units. Product picture

VAMP 120 & 121. Arc flash detection units. Product picture Arc flash detection units VAMP 120 and 121(D) are extremely fast arc flash detection units for LV and MV switchgear and controlgear. The units are especially designed to increase the safety and to minimize

More information

SCHEDULE OF RATES SHEET PRELIMINARIES

SCHEDULE OF RATES SHEET PRELIMINARIES Page : 1 PRELIMINARIES 1 CONTAINER BUDGET ALLOWANCE 1,100.00 1,100.00 1 SUPERVISION 3,900.00 3,900.00 1 ACCOMMODATION 5,390.00 5,390.00 1 TRAVEL ALLOWANCE 7,800.00 7,800.00 Sub- 18,190.00 18,190.00 Page

More information

User Information Sheet 008 : 2010

User Information Sheet 008 : 2010 User Information Sheet 008 : 2010 Formerly UIS008, July 2009 ELECTRICAL INSTALLATIONS ASSOCIATED WITH BULK LPG INSTALLATIONS 1. Introduction This Information Sheet describes some of the principles and

More information

5SM6 AFD unit preventive, proven, standard-compliant

5SM6 AFD unit preventive, proven, standard-compliant The 5SM6 AFD unit order now! 5SM6011-2 AFD unit (16 A) Miniature circuit breaker 1+N, 6 ka, 1 MW (16 A) MCB 1+N,1 MW 10 A 5SY6010-6 5SY6010-7 MCB 1+N, 1 MW 13 A 5SY6013-6 5SY6013-7 MCB 1+N, 1 MW 16 A 5SY6016-6

More information

Electrisaver User and Installation Instructions

Electrisaver User and Installation Instructions Electrisaver User and Installation Instructions The Electrisaver push button boost timer can be used to control immersion elements and other electrical appliances up to 3kW or as an override/extension

More information

Flostop TS D7E and A8E. Operation Manual

Flostop TS D7E and A8E. Operation Manual Flostop TS D7E and A8E Operation Manual United Kingdom Spectron Gas Control Systems Ltd, Unit 4, ATU1, University of Warwick science Park, Coventry, +44 (0) 24 7641 6234 sales@spectron-gcs.com Germany

More information

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.

More information

Molded Case Circuit Breakers, Bulletin 140G

Molded Case Circuit Breakers, Bulletin 140G ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION Molded Case Circuit Breakers Bulletin 140G NOTICE: The specification guidelines in this document are intended to aid in the specification

More information

SPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents.

SPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents. Tender Specification Package #: Trace Heating Engineering Specification for Pipe Frost Protection Contents Y24 Trace heating 2 Appendix A Schematics & Drawings 8 Prepared by: Authorised by: Issued

More information

ClimaSys Resistance heaters Selection guide

ClimaSys Resistance heaters Selection guide Selection guide Insulated resistance heaters Power W Voltage Type of connection Terminal block Cable 87504 10 12-36 DC X 87501 10 110-250 AC X 87512 21 12-36 DC X 87502 21 110-250 AC X 87518 55 12-36 DC

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

PASSION FOR POWER. COMPANY PROFILE. More information at made in GERMANY. since 1931

PASSION FOR POWER. COMPANY PROFILE. More information at   made in GERMANY. since 1931 PASSION FOR POWER. COMPANY PROFILE More information at www.hensel-electric.de/en made in GERMANY since 1931 made in GERMANY since 1931 HENSEL - our passion is perfection Electrical power drives us forward.

More information

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.

More information

30KW ELECTRIC FAN HEATER

30KW ELECTRIC FAN HEATER 30KW ELECTRIC FAN HEATER MODEL NO: DEVIL 7030 PART NO: 6935458 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product,

More information

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch Project: Customer: Engineer: Pump Manufacturer: Technical Data Submittal Document Model VPS + VPU Pressure Limiting (VFD) with Soft Start Bypass with Automatic Transfer Switch Contents: Data Sheets Dimensional

More information

TPF Series Ozone Generators

TPF Series Ozone Generators TPF Series Introduction The model TPF is modular series of medium frequency ozone generators employing the latest electronics. The generators are manufactured by Ozono Elettronica Internazionale (OEI)

More information

Circuit Protector. GCP Series. Features. Electromagnetic Overcurrent Protection. Approvals. AC/DC Dual Voltage. Easily Identified ON/OFF Indicator

Circuit Protector. GCP Series. Features. Electromagnetic Overcurrent Protection. Approvals. AC/DC Dual Voltage. Easily Identified ON/OFF Indicator Circuit Protector GCP Series Features Electromagnetic Overcurrent Protection Overcurrent is prevented by an electromagnet, which is more appropriate and effective for circuit protection than the thermostatic

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2011-01-24 Page 1 of 18 Report Reference # E183863-A17-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

Operator s Manual. IP-100 Immersion Probe Cooler

Operator s Manual. IP-100 Immersion Probe Cooler Operator s Manual IP-100 Immersion Probe Cooler 110-810 04.27.11 Table of Contents Introduction... 3 General Information... 3 General Safety Information... 3 Safety Recommendations... 4 Unpacking Your

More information

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU with Automatic Power Transfer Switch Contents: NOTE: The drawings included in this package are for controllers covered under our standard

More information

The No.1 choice for Veterinary care and animal recovery.

The No.1 choice for Veterinary care and animal recovery. The No.1 choice for Veterinary care and animal recovery. Specialized intensive care units designed for optimum comfort, care and control. cell activation Strengthen immunity Better blood flow prevention

More information

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl enproteko.com Temperature Monitoring Relay K8AB-TH Compact and Slim Relay Ideal for Temperature Alarms and Monitoring Excessive increases can be prevented and abnormal s can be monitored. Temperature monitoring

More information

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes

More information

RAYCHEM NGC-30 COMPONENTS

RAYCHEM NGC-30 COMPONENTS PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM PRODUCT OVERVIEW CABLE DUCT Card Rack Modules TERMINAL STRIP PLINTH MAIN SWITCH 800 mm USER INTERFACE

More information

Smart Classroom Design

Smart Classroom Design RWANDA EDUCATION BOARD P.O Box 3817 KIGALI Telephone : (+250) 255121482 E-mail: info@reb.rw Website: www.reb.rw Smart Classroom Design Concept Note September 2018 Background Rwanda Vision 2020 aims at

More information

VIESMANN. Installation instructions VITODENS 200-W. for contractors

VIESMANN. Installation instructions VITODENS 200-W. for contractors Installation instructions for contractors VIESMANN Vitodens 200-W Type WB2C, 45 and 60 kw Wall mounted gas condensing boiler Natural gas and LPG version VITODENS 200-W 1/2010 Dispose after installation.

More information

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL INLINE CENTRIFUGAL FAN OPERATION MANUAL www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 4 Fan design 4 Delivery

More information

M15051) INSTRUCTION MANUAL

M15051) INSTRUCTION MANUAL INSULATION GUARD MEG-1000 (Code M15051) INSTRUCTION MANUAL ( M98122001-20 / 05A ) (c) CIRCUTOR S.A. Insulation guard MEG-1000 1.- BASIC INSTRUCTIONS 1.1.- Delivery spot check This manual is issued to help

More information

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

DEB71. Earth Leakage Monitoring Relay. Benefits. Description Earth Leakage Monitoring Relay Benefits Adjustable trip level. Adjustable leakage threshold from 30mA to 5A or from 300mA to 30A. 2 outputs. Two relay outputs provide, besides the alarm signal an additional

More information

CentaurPlus ZW and HRT4-ZW

CentaurPlus ZW and HRT4-ZW CentaurPlus ZW and HRT4-ZW Installation Instructions The Horstmann CentaurPlus ZW combined wireless room stat and timeswitch allows a combi boiler system to have a room thermostat added without the need

More information

TECHNICAL DATA SHEET. FreeSpace DS 40SE 1 OF 8. Loudspeaker. Product Overview. Product Information. Key Features. Applications

TECHNICAL DATA SHEET. FreeSpace DS 40SE 1 OF 8. Loudspeaker. Product Overview. Product Information. Key Features. Applications Product Overview The Bose FreeSpace DS 4SE loudspeaker is a high-performance, surface-mount loudspeaker designed for foreground and background music and speech reproduction in a wide range of commercial

More information

Installation, operating and servicing instructions

Installation, operating and servicing instructions English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes

More information

AIRDATA COMPUTER ALTITUDE ENCODER AVIONICS COOLING FANS. Model Part Number LIST PRICE DESCRIPTION

AIRDATA COMPUTER ALTITUDE ENCODER AVIONICS COOLING FANS. Model Part Number LIST PRICE DESCRIPTION 2015 PRICE LIST AIRDATA COMPUTER Model Part Number DESCRIPTION LIST PRICE SAC 7-35 705548-00 SAC 7-35-01 705548-01 The TSO d SAC 7-35 is an airdata/fuel system designed for todays integrated navigation

More information

Installation Instructions

Installation Instructions ELCU-200 Control Unit Circle CUT-OUT R8.5 mm Push to Test Specifications Cir.# Remote Activation Voltages... 120/277VAC 50/60Hz Max Load Requirements Ballast... 20A @120/277VAC Incandescent... 10A @120VAC

More information

Mounting and operating instructions KEMPER KTS temperature-controlled 3-directional reversing valve Figure DN 32 DN 80

Mounting and operating instructions KEMPER KTS temperature-controlled 3-directional reversing valve Figure DN 32 DN 80 Mounting and operating instructions KEMPER KTS temperature-controlled 3-directional reversing valve Figure 955 01 DN 32 DN 80 Figure 1: DN 32 - DN 50 Figure 2: DN 65 - DN 80 Table of Contents 1 General

More information