DIN /DIN Aseptic Flange Union for ISO 1127 Schedule Pipe

Size: px
Start display at page:

Download "DIN /DIN Aseptic Flange Union for ISO 1127 Schedule Pipe"

Transcription

1 / Aseptic Flange Union for ISO 1127 Schedule Pipe DIN / Aseptic Flange Union This range of aseptic fittings has been developed by the German hygienic industry to meet the exacting needs of the food, chemical and pharmaceutical industries. Three designs of pipe fittings have been tailored to accept 2 different styles of aseptic seals that effect a smooth interface within the pipe work whilst simultaneously achieving a metal to metal seat behind the joint. The seal sections used are referenced as Form A and Form B and both have distinctive profiles that are easily recognised. Form A is an O Ring Joint whilst Form B is a 2-part Square seal with a secondary internal diamond section. Available with optional lengths to suit Orbital and Manual Welding, these unions have been designed to match tube and pipe specifications in DIN 11850; ISO 2037, ASM BP 2002 and BS 4825 Part 1 and also ISO 1127 for schedule pipe. Size range: NS8 to NS100 Materials: 316L SS Related standards: DIN Form A - Aseptic Screwed Union Form A - Aseptic Flange Union DIN Form A - Aseptic Tri-Clamp Union DIN / / ISO 1127 ISO 2037 / BS 4825 /ASM BP 2014 DIN (Type 1 only) DS Aseptic Flange Union ISO 1127 V 1.1 Page No: 1

2 A06 / Form A Male Nut Flange 316L SS - ISO 1127 Size A B C L1 (Orbital Weld) L2 (Manual Weld) NS NS NS NS NS NS NS NS NS NS NS A06-A A06-A A06-A A06-A A06-A A06-A A06-A A06-A A06-A A06-A A06-A A06-A A06-A A06-A A06-A A06-A A06-A A06-A A06-A A06-A A06-A A06-A Dimension L includes the sealing face raised spigot DS Aseptic Flange Union ISO 1127 V 1.1 Page No: 2

3 A06F / Form A Female Liner Flange - 316L SS - ISO 1127 Size A B C NS NS NS NS NS NS NS NS NS NS NS L1 (Orbital Weld) L2 (Manual Weld) A06F-A A06F-A A06F-A A06F-A A06F-A A06F-A A06F-A A06F-A A06F-A A06F-A A06F-A A06F-A A06F-A A06F-A A06F-A A06F-A A06F-A A06F-A A06F-A A06F-A A06F-A A06F-A Dimension L includes the sealing face raised spigot DS Aseptic Flange Union ISO 1127 V 1.1 Page No: 3

4 DIN 11864/11853 Form A O Ring Union Seal ISO 1127 Size D1 D Section PDM FKM NS A A030-V0135 NS A A030-V0172 NS A A030-V0213 NS A A030-V0269 NS A A030-V0337 NS A A030-V0424 NS A A030-V0483 NS A A030-V0603 NS A A030-V0761 NS A A030-V0889 NS A A030-V1143 DS Aseptic Flange Union ISO 1127 V 1.1 Page No: 4

5 A06G / Form A Male Nut Flange Blank - 316L SS - ISO 1127 Size A NS 8 54 NS NS NS NS NS NS NS NS NS NS D 11.5 A06G-A A06G-A A06G-A A06G-A A06G-A A06G-A A06G-A A06G-A A06G-A A06G-A A06G-A1143 Dimension D includes the sealing face raised spigot DS Aseptic Flange Union ISO 1127 V 1.1 Page No: 5

6 A06H / Form A Female Liner Flange Blank - 316L SS - ISO 1127 Size A NS 8 54 NS NS NS NS NS NS NS NS NS NS D 10 A06H-A A06H-A A06H-A A06H-A A06H-A A06H-A A06H-A A06H-A A06H-A A06H-A A06H-A1143 Dimension D includes the sealing face raised spigot DS Aseptic Flange Union ISO 1127 V 1.1 Page No: 6

F4060 RESILIENT SEATED GATE VALVES

F4060 RESILIENT SEATED GATE VALVES F4060 RESILIENT SEATED GATE VALVES BS 5163 AS 2638 EN 1074 FM UL EN 1171 ISO 7259 The Keystone Figure 4060 series is a Tyco manufactured resilient seated gate valve available in a wide variety of configurations

More information

For calls outside the UK Telephone or Fax TETRA PAK PUMPS FREEPHONE: Centrifugal Pump Single Shaft Seal Type ALC-1

For calls outside the UK Telephone or Fax TETRA PAK PUMPS FREEPHONE: Centrifugal Pump Single Shaft Seal Type ALC-1 Centrifugal Pump Single Shaft Seal 2 Freephone lines are open between 8.00am and 5.30pm Monday to Friday FREEFAX: 0800 801404 TETRA PAK PUMPS Centrifugal Pump Single Shaft Seal Motors: 3000 r/min, 3-phase

More information

Airflex Radial & ISO Thermal pipe

Airflex Radial & ISO Thermal pipe Airflex Radial & ISO Thermal pipe Semi rigid ducting Key Features Zero leakage ensures highest performance 70% time saving on installation Interchangeable ducting system (75mm round / 51mm x 114mm oval)

More information

Safety vacuum drying oven for flammable solvents

Safety vacuum drying oven for flammable solvents VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with

More information

NEMO BY. Industrial applications in all business fields for low to high viscosity fluids, with or without solids

NEMO BY. Industrial applications in all business fields for low to high viscosity fluids, with or without solids NEMO BY Industrial applications in all business fields for low to high viscosity fluids, with or without solids Compact design with directly flanged drive Low investment, operating and maintenance cost

More information

Temperature Measurement

Temperature Measurement /2 Transmitters for mounting in sensor head /6 SITRANS TH100 two-wire system (Pt100) /10 SITRANS TH200 two-wire system universal /17 SITRANS TH00 two-wire system /24 SITRANS TH400 fieldbus transmitter

More information

VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification

VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet 34-VF-03-09 29 TH May, 2009 Specification The universal solution for the process industry VERSAFLOW is the only sensor for mass flow in its class

More information

GESTRA Valves for Pure and Sterile Steam Systems. Intelligent solutions for sensitive processes

GESTRA Valves for Pure and Sterile Steam Systems. Intelligent solutions for sensitive processes GESTRA Valves for Pure and Sterile Steam Systems Intelligent solutions for sensitive processes GESTRA Your Competent Partner on Both Sides of the Sterile Boundary The very highest demands on process and

More information

BLAUDIECK DS Steam- and hot water hose

BLAUDIECK DS Steam- and hot water hose BLAUDIECK DS Steam- and hot water hose Kennzeichnung: Red-white logos BLAUDIECK on blue cover The Blaudieck DS steam- and hot water hose has been developed for reliable cleaning purposes in various industrial

More information

Problem-solvers The Radiator Solution Range

Problem-solvers The Radiator Solution Range Simplex Problem-solvers Problem-solvers The Radiator Solution Range I Height and depth compensation I Continuously swivelling connections I Reversal of supply and return flow I Quick and clean radiator

More information

BS 5163 EN 1074 EN 1171 ISO 7259 AS 2638 FM UL

BS 5163 EN 1074 EN 1171 ISO 7259 AS 2638 FM UL F4060RESILIENT SEATED GATE VALVES BS 5163 EN 1074 EN 1171 ISO 7259 AS 2638 FM UL The Keystone Figure 4060 series is a Tyco manufactured resilient seated gate valve available in a wide variety of configurations

More information

DAIRY SECTION STAINLESS STEEL DAIRY FITTINGS COMPLIES WITH 3A SANTARY GUIDELINES

DAIRY SECTION STAINLESS STEEL DAIRY FITTINGS COMPLIES WITH 3A SANTARY GUIDELINES 304 STAINLESS STEEL FITTINGS COMPLIES WITH 3A SANTARY GUIDELINES TRI-CLOVER FERRULE HALF FERHALF32 32mm 1-1/4 FERHALF38 38mm 1-1/2 FERHALF50 50mm 2 FERHALF63 63mm 2-1/2 FERHALF76 76mm 3 FERHALF101 101mm

More information

Sanitary Centrifugal Pumps

Sanitary Centrifugal Pumps APV PUMPS Sanitary Centrifugal Pumps W+ SERIES W+ Series Sanitary Centrifugal Pumps Engineering excellence, allied to stringent quality control, ensures that SPX FLOW s unrivalled range of APV products

More information

Aeon International Ltd Blenheim House, Falcon Court Preston Farm Industrial Estate Stockton on Tees TS18 3TS, United Kingdom

Aeon International Ltd Blenheim House, Falcon Court Preston Farm Industrial Estate Stockton on Tees TS18 3TS, United Kingdom Aeon International Ltd Blenheim House, Falcon Court Preston Farm Industrial Estate Stockton on Tees TS18 3TS, United Kingdom +44 (0)1642 611826 +44 (0)1642 617487 info.uk@aeon-online.com Aeon International

More information

Ultra Boiler Series 1 & 2 Jacket Parts

Ultra Boiler Series 1 & 2 Jacket Parts GAS Ultra Boiler Series 1 & 2 Jacket Parts 9 10 8 6 7 1 5 2 3 Fig. Part Description Model Mfr. 1 383-500-135 Jacket Front Door 595-000-000 595-000-001 595-000-002 595-000-003 Panel Door Jacket Plastic

More information

BAGI - MIXER. Magnetically Driven Bottom Mounted Mixers. Sealless ZERO LEAKAGE Design. CIP / SIP Capable. Non Contaminating Mixing

BAGI - MIXER. Magnetically Driven Bottom Mounted Mixers. Sealless ZERO LEAKAGE Design. CIP / SIP Capable. Non Contaminating Mixing BAGI - MIXER Magnetically Driven Bottom Mounted Mixers Sealless ZERO LEAKAGE Design CIP / SIP Capable Non Contaminating Mixing Completely Drainable Design Mixing Volume from 10L to 20000L Welcome to KWENG

More information

ROTARY SPRAY HEADS CATALOGUE

ROTARY SPRAY HEADS CATALOGUE ROTARY SPRAY HEADS CATALOGUE Via G.Pastore 7/A - 43058 Sorbolo (PR) ITALY Tel. +39.0521.698578 - Fax +39.0521.030554 www.caggiatiinox.com - info@caggiatiinox.com Rotary head series 64 Construction: The

More information

High Pressure Manways CODAP 2000 & PED 96/23/CE

High Pressure Manways CODAP 2000 & PED 96/23/CE High Pressure Manways CODAP 2000 & PED 96/23/CE Alchem offer a range of High-Pressure manways designed and built to comply with the European Pressure Directive 97/23/CE and also with the pressure vessel

More information

For the sterilization of pharmaceutical products using the hot water cascade system.

For the sterilization of pharmaceutical products using the hot water cascade system. For the sterilization of pharmaceutical products using the hot water cascade system. MMM. Protecting human health. and controlled sterilization is an important in research, and the production pharmaceuticals

More information

Plate Coil Heat Exchangers

Plate Coil Heat Exchangers Plate Coil Heat Exchangers UK Exchangers Ltd Unit 55 Stilebrook Road, Olney, Buckinghamshire, MK46 5EA, United Kingdom Tel: 0044 (0)1234 244320 Email: sales@ukeltd.com Web: www.uk-exchangers.com Plate

More information

FT14 Ball Float Steam Trap (Screwed)

FT14 Ball Float Steam Trap (Screwed) Page 1 of TI-S02-0 ST Issue 9 Cert. No. LRQ 096008 ISO 9001 FT14 Ball Float Steam Trap (Screwed) Description The FT14 is an SG iron bodied ball float steam trap having stainless steel working internals

More information

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN) Issue Date: 4/06 GESTRA Steam Systems Thermostatic Steam Traps MK 45-, MK 45-2 PN 40, DN 5, 20, 25 (½", ¾", ") Product Range A MK 45- MK 45-2 Description Thermostatic steam trap with membrane regulator.

More information

Rhino SD2/XD2 ARW Air Circuit Module for 125-mm Frames

Rhino SD2/XD2 ARW Air Circuit Module for 125-mm Frames Instruction Sheet P/N 1111 01 Rhino SD/XD ARW Air Circuit Module for 15-mm Frames Description See Figure 1. The Rhino SD/XD ARW (automatic removal of weepage) air circuit module for 15-mm frames consists

More information

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI)

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI) Page 1 of 11 Parts List Remote Water Quality System Standard Equipment (supplied by EPI) 20sq ft Skimmer-Filter Remote Water Quality Plumbing Kit Heater-Controller Keypad Control 220V 3/4HP Circulation

More information

Serial number range. From S.N.: FXHOOKC14B-1001 To S.N.: FXHOOKC15B-1008 From S.N.: FXHOOK14B-1001 To S.N.: FXHOOK15B-1036

Serial number range. From S.N.: FXHOOKC14B-1001 To S.N.: FXHOOKC15B-1008 From S.N.: FXHOOK14B-1001 To S.N.: FXHOOK15B-1036 Parts Manual Serial number range 2500 kg Fixed Hook 5000 kg Fixed Hook From S.N.: FXHOOKC14B-1001 To S.N.: FXHOOKC15B-1008 From S.N.: FXHOOK14B-1001 To S.N.: FXHOOK15B-1036 2000 mm/2000 kg Mech Jib 4000

More information

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections Page 1 of TI-P615-03 ST Issue IFT57 SG Iron ISO 9001 Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections Cert. No. LRQ 0963008 IFT57H DN0 (horizontal shown) DN15 (vertical shown)

More information

Air operated diaphragm pumps. Catalogue 2011 rev 1

Air operated diaphragm pumps. Catalogue 2011 rev 1 Air operated diaphragm pumps Catalogue 2011 rev 1 General your reliable pumpchoice With experience from industrial fluid handling and pump manufacture since 1970, we know what you as a customer require

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview The compact flowmeter SITRANS FC410 can be ordered for industrial, hygienic or NAMUR service. Intended for integration into OEM skids, machines or pre-assembled plant systems, the flowmeter is

More information

W+ Series SANITARY CENTRIFUGAL PUMPS

W+ Series SANITARY CENTRIFUGAL PUMPS W+ Series SANITARY CENTRIFUGAL PUMPS SPX FLOW is a leading innovator of solutions with decades of experience in centrifugal pump design, covering premium brands such as APV and Waukesha Cherry- Burrell.

More information

GV Series 4 Section Assembly

GV Series 4 Section Assembly GV Series 4 Section Assembly 192 Current Service Parts GV Series 4 Section Assembly Fig. No. Part No. Description Size Notes 1 322-200-280 Section Assembly, GV-3 (Repair Kit Required) 3 1 322-200-281 Section

More information

Control unit PPT/RS,, Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and contr

Control unit PPT/RS,, Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and contr Control unit PPT/RS,, 0111636 Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and control unit is 10 metres when feed pressure is 0.6 MPa.

More information

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS 1. FEATURES The Type N Trap range is particularly suitable for high pressure/high temperature trapping applications

More information

Lyovapor L-300 Technical data sheet

Lyovapor L-300 Technical data sheet Lyovapor L-300 Technical data sheet With Infinite-Technology the Lyovapor L-300 offers continuous sublimation for the first time with two alternate working and automatically hygienically cleaned condensers

More information

GaLvaniZEd STEEL. STainLESS STEEL. Sprinkler systems. Pegler Yorkshire

GaLvaniZEd STEEL. STainLESS STEEL. Sprinkler systems. Pegler Yorkshire GaLvaniZEd STEEL STainLESS STEEL Sprinkler systems Pegler Yorkshire Pegler Yorkshire Unrivalled quality, innovation, customer service and long-term value for money As part of the global Aalberts Industries

More information

For very low to medium/high conductivity: Where optimal performance is essential. INGOLD Leading Process Analytics

For very low to medium/high conductivity: Where optimal performance is essential. INGOLD Leading Process Analytics INGOLD Leading Process Analytics WideRange TM technology Exceptional measurement ranges Stable measurement signals Vario Pin connector (IP 68) MaxCert TM For very low to medium/high conductivity: Where

More information

ASEPTIC SAMPLING VALVES SANITARY SAMPLING VALVES SANITARY SAMPLING BOTTLE TANK BOTTOM ASEPTIC VALVE

ASEPTIC SAMPLING VALVES SANITARY SAMPLING VALVES SANITARY SAMPLING BOTTLE TANK BOTTOM ASEPTIC VALVE BOLLETTINO -17 AUTOMATIC ORBITAL TANK WASHING The most sophisticated tank washing equipment, where high impact fluid jets is combinated to slowly rotation around one vertical and one horizontal axis. The

More information

Operation and Maintenance Manual Chamber Conditioning Unit, CCU 06. Document Number: EC OM 6847 Revision: 3

Operation and Maintenance Manual Chamber Conditioning Unit, CCU 06. Document Number: EC OM 6847 Revision: 3 Operation and Maintenance Manual Chamber Conditioning Unit, CCU 06 Part Number: KI40053 Document Number: EC OM 6847 Revision: 3 TABLE OF CONTENTS Table Of Contents Approval Sheet List of Abbreviations

More information

NON-SLAM DYNAMIC ARV FAF 7330

NON-SLAM DYNAMIC ARV FAF 7330 PRODUCTION STANDARTS DN50 DN250 PN 10-16 Design EN 1074-4 End Connection EN 1092-2 / ISO 7005-2 Marking EN 19 Tests EN 12266 Corrosion Protection Industrial Epoxy Features y Non-Slam Dynamic ARV to be

More information

Ribbon Blenders and other horizontal mixers

Ribbon Blenders and other horizontal mixers Mixing Technology Ribbon Blenders and other horizontal mixers Double Ribbon Paddle Ribbon Paddle agglomerating batching coating cooling conveying deaerating defibrating disagglomerating dispersing dissolving

More information

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A Worldwide Contacts www.tyco-fire.com FASTFLEX Model YN25, YB25, and YB28 Flexible Hose Europe, Middle East, and Africa Only General Description The TYCO FASTFLEX Flexible Hose is a unique sprinkler drop

More information

Continental Industries STEEL COUPLINGS or FAX Visit

Continental Industries STEEL COUPLINGS or FAX Visit Continental Industries STEEL COUPLINGS 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is

More information

Product Brochure Modular Air Handling Units CAIRplus. Multiflow liquid-coupled energy recovery system

Product Brochure Modular Air Handling Units CAIRplus. Multiflow liquid-coupled energy recovery system Product Brochure odular Air Handling Units CAIRplus ultiflow liquid-coupled energy recovery system CAIRplus - Air handling units Air treatment (heating, cooling, filtering, humidification and dehumidification)

More information

Boss Fittings KORD INDUSTRIAL INC

Boss Fittings KORD INDUSTRIAL INC UFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFACTU Boss Fittings KORD INDUSTRIAL INC. 866.874.5673 Products Recommended for Steam Service Quick Disconnect

More information

Group 35 Drainage System. This group contains information on the holding tanks. equipment applied to the coach. ...Sink and Shower Strainers

Group 35 Drainage System. This group contains information on the holding tanks. equipment applied to the coach. ...Sink and Shower Strainers Group 5 Drainage System GENERAL: This group contains information on the holding tanks and drainage system. It also covers any waste destruction equipment applied to the coach. SPECIFICS: As applicable...drain

More information

Application of DVGW Technical Rules in relation with European Standards

Application of DVGW Technical Rules in relation with European Standards in relation with European Standards INOGATE Study Visit, 9 th to 11 th of May 2014 Dipl.-Ing. Detlef Jagodzinski, DVGW, Bonn Product Standardisation Standardisation committee Gastechnology (NAGas) of DIN.

More information

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2 Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43- Type 43-2 Application Regulators for district heating supply systems, heat generators, heat exchangers, and other building

More information

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation Standard C Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard C Standard C The Standard C thermostatic

More information

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description Worldwide Contacts www.tyco-fire.com Model AV--00 Alarm Valve With and Without Model RC- Retard Chamber European Conformity Valve Trim General Description The TYCO Model AV--00 Alarm Valves DN, DN0, DN0,

More information

SITRANS T temperature transmitters A broad product family for every application. sitrans

SITRANS T temperature transmitters A broad product family for every application. sitrans SITRANS T temperature transmitters A broad product family for every application sitrans The SITRANS T family High-precision, intrinsically safe, and available for a wide variety of sensors Whether you

More information

Say heating. Say Herz. HERZ-Supply Engineering

Say heating. Say Herz. HERZ-Supply Engineering HERZ-Supply Engineering Medium Temperature Control Pressure Control Fittings Control Fittings Lock Shields and Isolators Accessories Spare Parts Say heating. Say Herz. HERZ Valves UK Progress House [ Moorfield

More information

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS IMPORTANT Please read these instructions before fitting any traps. The following pages describe how each type of GEM Trap should be installed. If you are unsure

More information

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Connection set. Radiator connection set for thermostatic and manual operation Ø 12 Connection set Radiator connection set for thermostatic and manual operation Data sheet for 1 7650 00 Issue 0405 Control valves Connection pipe Ø 12 L L = 600 1 7650 00 L = 1000 1 7650 01 Bypass bodies

More information

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN DIVISION 21 - FIRE SUPPRESSION (REFER TO SECTION 23 05 00 FOR BASIC FIRE SUPPRESSION REQUIREMENTS) 21 05 00 Common Work Results for Fire Suppression 21 13 13 Wet-Pipe Sprinkler Systems END OF SECTION FIRE

More information

Installation Instructions for Med Touch Master Alarms - Wireless

Installation Instructions for Med Touch Master Alarms - Wireless Installation Instructions for Med Touch Master Alarms - Wireless Master Alarm Panel Local Sending Master Alarm Panel - Master Alarm Panel - Repeater Page 1 of 7 Common Master Alarm Back Box Assembly Assembling

More information

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 0772150/4 IM-P077-02 ST Issue 4 S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning

More information

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME GESTRA Steam Systems BK 37 BK 28 BK 29 Installation Instructions 818689-00 Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME Contents Important Notes Page Usage for the intended purpose...4

More information

Centrometal d.o.o. - Glavna 12, Macinec, Hrvatska, tel: , fax: THE BOILER PelTec 12 WITH SPARE PARTS LIST

Centrometal d.o.o. - Glavna 12, Macinec, Hrvatska, tel: , fax: THE BOILER PelTec 12 WITH SPARE PARTS LIST HEATING TECHNIQUE Centrometal d.o.o. - Glavna 12, 40306 Macinec, Hrvatska, tel: 040 372 600, fax: 040 372 611 DISPOSITIONAL (EXPANDED) VIEW OF THE BOILER PelTec 12 WITH SPARE PARTS LIST PelTec12 EPKRD-PelTec-12-01/20-ENG-euro

More information

PLUMBING FIXTURES Reserved

PLUMBING FIXTURES Reserved CHAPTER 27 PLUMBING FIXTURES Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 395R This page left intentionally blank. 396R 2003 INTERNATIONAL RESIDENTIAL CODE SECTION P2708 SHOWERS P2708.1 General. Shower

More information

DEKO Washer-disinfector WASHROOM SYSTEMS

DEKO Washer-disinfector WASHROOM SYSTEMS DEKO 2000 Washer-disinfector WASHROOM SYSTEMS RELIABLE PERFORMANCE The DEKO 2000 is designed and constructed to meet the performance and design requirements stated in EN ISO 15883-1 Washer-disinfectors

More information

SERVICE PARTS LIST for

SERVICE PARTS LIST for T-0PL Manual SERVICE PARTS LIST for MODELS AC0 & AC0 With BT Digital Display or 80P/8P Electronic Thermostat T-0PL REV. 06/0 0 Mobile Climate Control TABLE OF CONTENTS TABLE OF CONTENTS... i CONDENSER

More information

Gas 220 Ace Cascade Assembly Manual

Gas 220 Ace Cascade Assembly Manual Gas 220 Ace Cascade Assembly Manual 1 Dear Customer, Thank you very much for buying this appliance. Please read through the manual carefully before using the product, and keep it in a safe place for later.

More information

Hygiene & Textile Toys. Toys Safety Directive 2009/48/EC Annex II, Part V, Point 2.

Hygiene & Textile Toys. Toys Safety Directive 2009/48/EC Annex II, Part V, Point 2. Hygiene & Textile Toys. Toys Safety Directive 2009/48/EC Annex II, Part V, Point 2. Contents 1. Introduction 2. Overview 3. Textile Toys for Children Under 36 Months 4. Textile Toys for Children Under

More information

ROTARY VANE VACUUM PUMPS Exploded View DuraVane Rotary Vane Pumps Oil-Lubricated RVL301HH

ROTARY VANE VACUUM PUMPS Exploded View DuraVane Rotary Vane Pumps Oil-Lubricated RVL301HH Exploded View Pumps RVL0HH 95 SOUTH WOODLAND AVENUE, MICHIGAN CITY, IN 0-57 Please visit our website at Page Number Reference TOLL-FREE: 888-95-5 TEL.: 9-8-0 FAX: 9-8-0 www.dekkervacuum.com DWG //05 RVL0HH

More information

40 CDe ENCLOSURES AND DISTRIBUTION BOARDS FOR SPECIFIC STANDARDS

40 CDe ENCLOSURES AND DISTRIBUTION BOARDS FOR SPECIFIC STANDARDS 40 CDe - Surface-mounting enclosures - Spanish standard Standard: IEC 60670-1; IEC 60670-24 Degree of protection: IP40 Installation temperature: max. +60 C; min. -25 C Impact : IK 08 Heat : thermo-pressure

More information

Brownell Transformer Breathers

Brownell Transformer Breathers Transformer Moisture Control and Prevention Brownell Transformer Breathers 2 Transformer Breathers The failure or malfunction of many transformers or similar equipments can be directly attributed to the

More information

Troubleshooting the MPH 24FP Series Pedestal Hydrant

Troubleshooting the MPH 24FP Series Pedestal Hydrant MAPA Products P.O. Box 129 Naples, Texas 75568 Toll Free: 877 897 2371 How the Hydrant Works: Troubleshooting the MPH 24FP Series Pedestal Hydrant The design of the hydrant assembly is based on a venturi

More information

13.2 Component Illustrations, Parts Lists, and Part Numbers

13.2 Component Illustrations, Parts Lists, and Part Numbers Page 0 LAARS Heating Systems Section REPLACEMENT PARTS Use only genuine LAARS replacement parts.. General Information To order or purchase parts for the LAARS MagnaTherm Appliance, contact your nearest

More information

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

Band Heaters W A T L O W. Special Mica Barrel and Nozzle W A T L O W For over 80 years, Watlow has been solving complex and unique application problems with standard mica barrel and nozzle heaters. Watlow is continuously improving design and application knowledge

More information

BELGRAVIA Classic (Vertical Units) - Technical Data Sheet

BELGRAVIA Classic (Vertical Units) - Technical Data Sheet S & P Coil Products Limited BELGRAVIA Classic (Vertical Units) - Technical Data Sheet BELGRAVIA CLASSIC: CONSTRUCTION Each Belgravia Classic unit comprises a sheet metal case, fitted with inlet and outlet

More information

Opening Point Adjustment Range psig (kpa) Commercial Type Non-Corrosive RefrigerantsS (R) 160 to 260 (1103 to 1793) 70 to 150 (483 to 1034)

Opening Point Adjustment Range psig (kpa) Commercial Type Non-Corrosive RefrigerantsS (R) 160 to 260 (1103 to 1793) 70 to 150 (483 to 1034) Repair Parts V43 Series Description The V43 is a pilot pressure actuated modulating valve for use on water cooled condensers that require a large flow capacity. Valves open on pilot pressure increase.

More information

Installation S

Installation S Installation S59-3080 Thermostatic Mixing Valve with Optional Cabinet S59-3080RE (with Recess-Mounted Enamel Cabinet) S59-3080RS (with Recess-Mounted Stainless Steel Cabinet) S59-3080SE (with Surface-

More information

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation Standard Sheet for 6823/ 6824 Edition 1000 (0999) 6823 6824 Special Models 1

More information

WINE, BREWERY & SPIRITS SUPPLY CATALOG

WINE, BREWERY & SPIRITS SUPPLY CATALOG WINE, BREWERY & SPIRITS SUPPLY CATALOG Providing sanitary processing equipment and customized services since 1885 www.mgnewell.com MG Newell is a full service provider of sanitary equipment for wineries,

More information

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien HERZ-Thermostatic and Return Valves Standard Sheet for DE LUXE Edition 1000 (0999) This series consists of HERZ radiator thermostats, HERZ-TS-90 thermostatic valves and HERZ return valves. These components

More information

W75 Series PMO Compliant DOUBLE SEAT MIX PROOF VALVES

W75 Series PMO Compliant DOUBLE SEAT MIX PROOF VALVES W75 Series PMO Compliant DOUBLE SEAT MIX PROOF VALVES Food and beverage processing has never been more challenging. Margins are being squeezed, food safety is paramount and consumer demands for new products

More information

Installation. Part Number /0209

Installation. Part Number /0209 Installation The following picture replaces the one shown on page 3 of the boiler manual. 1. The change is the reversing of the orientation of the 3-way valve body (A - connects to system piping and B

More information

Thermostatic valves with radiator connection systems

Thermostatic valves with radiator connection systems Multilux Eclipse Thermostatic valves with radiator connection systems with two-point connection for two-pipe heating systems, with automatic flow limitation IMI HEIMEIER / Thermostatic heads and Radiator

More information

NOZZLES FOR BOTTLE, DRUM, AND TANK WASHING

NOZZLES FOR BOTTLE, DRUM, AND TANK WASHING NOZZLES FOR BOTTLE, DRUM, AND TANK WASHING TW 0216 SI/Metric TANK WASHING When choosing a suitable tank cleaning nozzle, three different designs are available: Stationary tank cleaning nozzles Rotating

More information

Instruction manual ISO-MIX Skid Mounted Pump Unit

Instruction manual ISO-MIX Skid Mounted Pump Unit Instruction manual ISO-MIX Skid Mounted Pump Unit ISO-MIX-FRONTPAGE.JPG OM SMPU-21-03, EN1 To the owner Dear owner, This Instruction Manual is your instant guide when dealing with your Alfa Laval equipment.

More information

Smoke extraction duct of sheet steel

Smoke extraction duct of sheet steel Smoke extraction duct of sheet steel The accessories that are available, as for example inspection openings, steel grilles, plenum boxes, ceiling diffusers, splitter attenuators, bends, tees and connecting

More information

Service Manual. Procedure. 4. Remove top cover. Top cover sub-assy. Remove the screws fixing top cover and then remove the top cover.

Service Manual. Procedure. 4. Remove top cover. Top cover sub-assy. Remove the screws fixing top cover and then remove the top cover. 4. Remove top cover Top cover sub-assy Remove the screws fixing top cover and then remove the top cover. 5. Remove electric box 1 Twist off screws fixing the electric box, pull out compressor wires and

More information

Installation and operating instructions. DK energy storage and DK energy buffer

Installation and operating instructions. DK energy storage and DK energy buffer Installation and operating instructions DK energy storage and DK energy buffer Edition: 08-2015 1 Preliminary note With this DK energy storage / DK energy buffer you purchased a DK quality product. The

More information

F Cleaning In Place. industries and NEW markets. challenges. Meeting the. of new WELCOME TO DELAVAN

F Cleaning In Place. industries and NEW markets. challenges. Meeting the. of new WELCOME TO DELAVAN F Cleaning In Place Meeting the challenges of new WELCOME TO DELAVAN industries and NEW markets SECTION INDEX TYPICAL SPRAY PATTERN Various types of fixed and rotating spray heads are specified in this

More information

4-1 1 / 2 " Tees / 2 " hole saw w/ 1/4" drill bit / 2 " Male slip plugs

4-1 1 / 2  Tees / 2  hole saw w/ 1/4 drill bit / 2  Male slip plugs Section 1: Parts List 1-50 Flex PVC pipe 2-1 1 / 2 " Ball Valves 4-1/2" 90 degree elbows 4 - Lengths of 1/2" PVC 4 - Jet bodies 4 - Jet nozzles 4 - Female slip/female slip unions 2 - Female slip/fpt union

More information

NOZZLES FOR BOTTLE, DRUM, AND TANK WASHING

NOZZLES FOR BOTTLE, DRUM, AND TANK WASHING NOZZLES FOR BOTTLE, DRUM, AND TANK WASHING TW 0213 SI/Metric TANK WASHING When choosing a suitable tank cleaning nozzle, three different designs are available: Stationary tank cleaning nozzles Rotating

More information

AWE Manhole size 500mm - mounted at pharmaceutical vessel

AWE Manhole size 500mm - mounted at pharmaceutical vessel AWE MANHOLE Central fast locking device Acc. AD - 2000/H5 and AWE Standards AWE - GmbH D - 87600 Kaufbeuren Am Riederloh 8 Tel: +49 (0) 8341-96400; FAX: +49 (0) 8341-964040 Central Fast Locking devises

More information

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR ELECTRICAL OR HIGH-DENSITY MAGNETIC ANTI-SCALE OR WATER CONDITIONING APPLIANCE IGC 91-2009 1. PURPOSE 1.1 The purpose

More information

Weed Instrument Application Driven Designs for Pharmaceuticals and Biotech

Weed Instrument Application Driven Designs for Pharmaceuticals and Biotech Weed Instrument Application Driven Designs for Pharmaceuticals and Biotech At Weed Instrument, we provide a complete line of sanitary and high-purity temperature sensors for accurate, reliable temperature

More information

Connecta System THE FIRE PERFORMANCE TUNNEL LIGHTING AND POWER SYSTEM

Connecta System THE FIRE PERFORMANCE TUNNEL LIGHTING AND POWER SYSTEM Connecta System THE FIRE PERFORMANCE TUNNEL LIGHTING AND POWER SYSTEM Connecta. Deliveri safety for tunnel e When it comes to specifying fire performance cables, zero halogen building wires and power cables,

More information

Parts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com

Parts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com Parts List Stackable Crescent Cuber Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3 hoshizakiamerica.com Number: 71384 Issued: 8-31-2017 Revised: 3-26-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering

More information

VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" THERMAL CUT-OUT THERMAL TRIP PLUG

VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4-20 x 1 THERMAL CUT-OUT THERMAL TRIP PLUG VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" 700300-013 2. THERMAL CUT-OUT 409560-001 THERMAL TRIP PLUG 409210-010 3. HEATER TERMINAL COVER VM99 2-4 HEATER TERMINAL

More information

Temperature Sensor TRG Original Installation Instructions English

Temperature Sensor TRG Original Installation Instructions English Temperature Sensor TRG 5-6.. EN English Original Installation Instructions 818597-05 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards

More information

Quick Start Guide , Rev. BB February Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union

Quick Start Guide , Rev. BB February Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union 00825-0100-4792, Rev. BB Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union NOTICE This installation guide provides basic guidelines for Rosemount 1495 Conditioning Orifice Plate. It does

More information

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal APT10-4.5 and Automatic Pump Traps for effective condensate drainage and removal 1 An innovative solution for effective heat User benefits Self contained compact unit. Operates with 8 in. installation

More information

Liquiphant T FTL20H. Technical Information

Liquiphant T FTL20H. Technical Information Technical Information Liquiphant T FTL0H Level limit switch for liquids in the foodstuff industry, compact design, housing made of corrosion-resistant stainless steel Application The Liquiphant T FTL0H

More information

CombiBloc Close-coupled centrifugal pumps

CombiBloc Close-coupled centrifugal pumps CombiBloc Close-coupled centrifugal pumps CombiBloc CombiBloc is the premier solution for pumping clean thin liquids in a very cost-effective way. The pump is part of Johnson Pump s Combi-system, a modular

More information

Vibracon LVL-A* Level limit switch for liquids, compact design

Vibracon LVL-A* Level limit switch for liquids, compact design Technical Information TI 364O/98/en/.07 8905 /07 0 Vibracon LVL-A* Level limit switch for liquids, compact design Application The Vibracon LVL-A* is a level limit switch for all kinds of fluids and is

More information

Installation Instructions

Installation Instructions Installation Instructions 6 KW and 11.5KW Basic Circulation Water Heater and Pump Application: The Basic Circulation Water Heater has been in use for nearly 50 years, and it is the most prevalent model

More information

EQ Joint High performance & Economical Price Stainless Steel welded Pipes & Tubes

EQ Joint High performance & Economical Price Stainless Steel welded Pipes & Tubes www.eqjiont.com EQ Joint High performance & Economical Price Stainless Steel welded Pipes & Tubes EQ Jointech introduce EQ joint system is based on the introduction of technology from Germany and Japan,

More information