1 UFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFACTU Boss Fittings KORD INDUSTRIAL INC
2 Products Recommended for Steam Service Quick Disconnect Fittings Quick disconnect fittings (socket and plug) are available in solid brass with stainless steel springs and locking balls in sizes ¼" through ½". Dry Disconnect Fittings Dry disconnect fittings (coupler and adapter) are available in stainless steel, with EPDM seals in sizes ¾" and ". GJ Boss Female Ground Joint Fittings GJ Boss female ground joint fittings are available in plated steel and/or iron in sizes ¼" through 6". Boss Female Washer Seal Fittings Boss female washer seal fittings are available in plated steel and/or iron in sizes 3/8" through 3". Boss Male Stems Boss male stems are available in steel bar stock in sizes ¼" through "; iron in sizes ¼" through 4"; 36 stainless steel in sizes ½" through 4" and brass in sizes ¾" through 3". Boss Clamps Boss clamps in the 2-bolt and 4-bolt style are available in plated iron in sizes ¼" through 3"; stainless steel in sizes ½" through 3" and brass in sizes ½" through. Boss clamps in the three-piece style are available in plated iron in sizes 3" through 6". 80 Steam Gauge Siphon 80 steam gauge siphon is available in steel and red brass pipe in ¼". In order to prevent live steam from entering a pressure gauge bourdon tube a siphon filled with water should be installed between the gauge and the process line. 250 PSIG Steam Ball Valve 250 lb. steam ball valves are available with a ed bronze valve, 36 stainless steel ball and stem in sizes ½" through. Note: Pressurized steam is an extremely dangerous commodity. Only hose, fittings, clamps and accessory items that have been approved for steam service should ever be used! Never use an unapproved item for steam service. Always follow the manufacturer's product recommendations for pressurized steam handling.
3 Steam Quick Disconnect Couplings Applications: Designed exclusively for steam applications, the coupler and plug are solid brass with stainless steel springs and locking balls. The coupler has a large plated steel sleeve especially designed for easier gripping with gloves. Two ethylene propylene O-rings in the coupler and one ethylene propylene O-ring in the plug provide double protection against leaks. Rated to 00 PSI gauge saturated steam (338 F). Warning: Do Not Disconnect Under Pressure!! poppet valve coupler Body Female /4" /4" B6-200S 3/8" 3/8" B6-300S / / B6-400S 3/4" 3/4" B6-600S " " B6-800S -/ -/ B6-200S poppet valve plug Body Female /4" /4" B7-200S 3/8" 3/8" B7-300S / / B7-400S 3/4" 3/4" B7-600S " " B7-800S -/ -/ B7-200S Dry Disconnect Fittings for Steam Service Applications: Designed to fit hoses carrying steam used in chemical (heating), pharmaceutical (disinfection and sterilization) and at loading bays Materials: coupling house and all inner parts: stainless steel seals: EPDM (standard), other materials available, unintentional separation is eliminated preventing accidents and avoiding unintended down time performance unaffected by surface rust lockable versions are available, Female Body coupler Stainless Steel 3/4" 56mm DDSC075SS " 56mm DDSC00SS Female Body adapter Stainless Steel 3/4" 56mm DDSA075SS " 56mm DDSA00SS
4 Boss Coupling System The spud part of the coupling serves as one half of the connection and is usually fixed to the equipment. The stem part that is clamped to the hose is the other half. The two halves are connected or disconnected by rotating the onto the spud. When connected they achieve a mechanical, as well as, a pressure seal. Services: Boss couplings are all-purpose hose couplings, universally recommended for steam hose connections. They are also widely used for air, water, fluid petroleum, chemicals and liquid petroleum gas up to " ID. Boss couplings can be applied to many types of rubber, synthetic, plastic, metallic or semi-metallic hose. Consult the factory for specific media capabilities. Purpose: Boss couplings supply a convenient ed fitting to connect two lengths of hose, or a single length to a male or female ed () outlet. Material: stem: ¼" - " plated steel, ¼" - 4" plated iron, 6" tubular steel spud: ¼" - " plated steel, ¼" - 6" plated iron : ¼" plated steel, 3/8" - 6" plated iron Seal Types: ground joint: copper or polymer seats washer: Klingersil C-440 Worn-out hose couplings can be dangerous. They should be checked regularly and replaced when necessary. Each coupling user should review applications and add safety devices where indicated.
5 GJ Boss Ground Joint Seal Positive Metal-to-Polymer Seal A leakproof seal is formed when the metal head of the stem makes contact with the patented polymer seat in the spud. The non-metallic polymer seat resists most chemicals found in manufacturing facilities. (reference corrosion resistance chart on pages ) recommended for steam service up to 450 F easy to seal works with existing fittings plated steel and / or iron use with Boss clamps Hose Shank x complete female stem knurled nut /4", 3/8" and 6" come only with copper seat spuds 2 /4" GF GBA 00 SLS /8" GF3 GCA 00 CB / GF6 GB 00 B / x 3/4" GF26- GB6-50 B /4" GF26 GB6 50 B2 25 KB2 " GF36 GB 50 B2 25 KB2 -/4" GF5 GB6 25 B / GF6 GB2 25 B GF8 2 GB B / GF96 GB3 5 B " GF GB36 5 B " GF4 GB46 5 B " GF20 GB66 2 B /4", 3/8" and 6" come only with copper seat spuds female spud male spud double spud Thread /4" GBC /8" GCC 00 GMC --- / GB3 00 GM3 GDB3 3/4" GB8 50 GM8 GDB3 " GB3 50 GM3 GDB3 -/4" GB8 25 GM8 GDB23 -/ GB23 25 GM23 GDB23 GB28 0 GM28 GDB28 2-/ GB33 5 GM33 GDB33 3" GB38 5 GM38 GDB38 4" GB48 5 6" GB68 2
6 Boss Fittings Boss Holedall Fittings Applications: Boss Holedall fittings are designed for air and liquid applications where a permanent, low profile clamping system is desired. Both fittings are supplied with carbon steel ferrules. specifications. ¾" " ½" 3" Hose OD From: -0/64" -5/64" -9/64" -30/64" -35/64" -39/64" -20/64" 2-/64" 2-9/64" 2-36/64" 2-4/64" 2-49/64" 3-26/64" 3-4/64" 3-49/64" Plated Iron / Steel To: Stainless Steel -4/64" -8/64" -22/64" -34/64" -38/64" -42/64" 2-8/64" 2-6/64" 2-40/64" 2-48/64" 2-56/64" 3-40/64" 3-48/64" 3-56/64" Not for steam service. GF26P GF26P2 GF26P3 GF36P GF36P2 GF36P3 GF6P GF6P2 GF6P3 GF8P GF8P2 GF8P3 GFP GFP2 GFP3 RGF6P RGF6P2 RGF8P RGF8P2 Boss Adapters These fittings have male or female s and are designed to fit the standard ground joint spuds.supplied with a wing nut, as shown. Feature: plated steel and / or iron male adapters ¾" " ¼" ½" GMAS6 GMAS GMAS6 GMAS2 GMAS26 Pkg uses a special, part # B27-3 female adapters ¾" " ¼" ½" GFAS6 GFAS GFAS6 GFAS2 GFAS26 Part is produced as a welded fabrication. Boss Wing Nut Caps plated steel and / or iron Supplied with chain and washer. For best results, use with washer style spuds and washers. Boss caps are not intended for pressure applications. ¾" and " ¼" and ½" 3" B2SC B7SC B27SC B37SC
7 36 Stainless Steel Ground Joint recommended for steam service up to 450 F complete female stem female spud ¾" RGF26 RGB6 RB2 RGB8 " RGF36 RGB RB2 RGB3 ¼" RGF5 RGB6 RB7 RGB8 ½" RGF6 RGB2 RB7 RGB23 RGF8 RGB26 RB27 RGB28 Brass Ground Joint complete female stem female spud ¾" BGF26 BGB6 BB2 BGB8 " BGF36 BGB BB2 BGB3 ¼" BGF5 BGB6 BB7 BGB8 ½" BGF6 BGB2 BB7 BGB23 BGF8 BGB26 BB27 BGB28 36 Stainless Steel Washer Style complete female stem female spud washer 2 ¾" RWF26 RB6 RB2 RB8 W2 " RWF36 RB RB2 RB3 W2 ¼" RWF5 RB6 RB7 RB8 W7 ½" RWF6 RB2 RB7 RB23 W7 RWF8 RB26 RB27 RB28 W27 2 washer is nitrile rubber bonded, non-asbestos Klingersil C-440 Brass Washer Style available, consult Dixon for pricing and availability.
8 Washer Type A Klingersil C-440 washer is inserted between the stem and spud. A leakproof seal is formed by rotating the and hammering it tight. recommended for steam service up to 450 F easy to seal works with existing fittings plated steel and / or iron use with Boss clamps found on pages 99 and 00. Boss Fittings Boss Washer Seal Hose Shank x complete female stem knurled nut 3/8" WF3 SS CB / WF6 B 00 B / x 3/4" WF26- B6-50 B /4" WF26 B6 50 B2 25 KB2 25 " WF36 B 50 B2 25 KB2 25 -/4" WF5 B6 25 B / WF6 B2 25 B WF8 B26 0 B / WF96 B3 5 B " WF B36 5 B female spud male spud double spud washer Thread 3/8" CC 00 WMC --- WBC / B3 00 WM3 DB3 W2 3/4" B8 25 WM8 DB3 W2 " B3 50 WM3 DB3 W2 -/4" B8 25 WM8 DB23 W7 -/ B23 25 WM23 DB23 W7 B28 0 WM28 DB28 W27 2-/ B W32 3" B38 5 WM38 DB38 W37 washer is nitrile rubber bonded, non-asbestos Klingersil C-440
9 Boss Male Stems plated steel barstock plated iron 36 stainless brass Hose x Plated Steel Bar Stock Plated Iron 36 Stainless Brass /4" x /8" MS4X ½" RMS /4" x /4" MSA ¾" RMS6 ¾" BMS6 /4" x 3/8" MSB " RMS " BMS 3/8" x /4" MS6X4 25 ¼" MS6 20 ¼" RMS6 ¼" BMS6 3/8" x 3/8" MSC 00 ½" MS2 20 ½" RMS2 ½" BMS2 3/8" x / MS6X8 25 MS26 0 RMS26 BMS26 / x /4" MS8X4 25 2½" MS3 5 2½" RMS3 --- / x 3/8" MS8X6 50 3" MS36 5 3" " BMS36 / x / MS 25 4" MS46 2 4" / x 3/4" MS8X /4" x / MS2X /4" x 3/4" MS /4" x " MS2X " x 3/4" MS6X " x " MS Use with Boss clamps on pages 99 and 00. For safety tags and safety tape see page 672. LP-Boss Male Stems schedule 80 stems meet NFPA 58 male end Boss Hose Menders beveled end Plated Steel 36 Stainless Schedule 80 Plated Steel Unplated Steel ¼" LP LP ½" LP LP LP LP26-80 LPB26 2½" LP " LP36 RLP LPB36 4" LP46 RLP " LP collars engage gripping fingers of Boss clamps ¾" - 3" plated iron; ½" plated steel ½" M ½" M2 ¾" M6 M26 " M 2½" M3 ¼" M6 3" M36 polymer seat Boss Spud x Hose Shank " GH3 GH2826 Steel
SECTION METERS AND GAGES FOR PLUMBING PIPING
SECTION 220519 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationHose. Propane Hose. 1 X-treme Low Temp Bobtail Hose. Large Transfer Hose. Construction Tube: Cover: Reinforcement: Temp. Range:
Propane For liquid or gaseous transfer of propane. 350 lb working pressure. All sizes are UL21 and CGA Type 1 approved. Cover is pin pricked for gas dissipation. I.D O.D Spirals Lbs per ft..610.15.760.22
More informationTANKER & STORAGE TANK PRODUCTS
Dry Bulk Dixon Dry Bulk products are designed for use with bulk trailers and truck blowers for the pneumatic transfer of dry bulk commodities such as powders, grains and plastic pellets. Other industrial
More informationLasco # Description Picture Lasco # Description Picture
TOILET REPAIR 02-1755 2 Pack, White Toilet Seat Hinge 663353 Washer, 02-3133 664625 3-1/16 O.D. x 2-1/8 I.D. x 3/16, Close Coupled Sponge Gasket, Toilet Tank To Bowl Gasket, Sponge Rubber Tank To Bowl
More informationPARTS STOCKED REPLACEMENT FAUCET BIBB SCREWS... SCREW ASSORTMENT MISC. 3 /8" BIBB LOC SCREW 1 /2" BIBB SCREW 1 /2" BIBB LOC SCREW 3 /8" BIBB SCREW
January 1, 2001 STOCKED REPLACEMENT FAUCET BIBB SCREWS... Parts-5L 3 /8" BIBB SCREW 6-32 GAUGE CHROME 35138- No. 1 3 /8" BIBB SCREW 10-24 GAUGE CHROME 35153- No. 16 3 /8" BIBB SCREW 8-32 GAUGE CHROME 35141-
More informationInstructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required.
Instructions *Image may vary slightly from actual product Tools Required Adjustable Wrench Groove Joint Pliers Pipe Wrench Phillips Screwdriver Pipe Tape or pipe thread compound Safety Tips If you solder
More informationInstructions. 110-KVD-CYSCH-AD-Z Chrome 110-KVD-CYSSS-AD-Z Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet
Instructions *Image may vary slightly from actual product Tools Required Adjustable Wrench Groove Joint Pliers Pipe Wrench Phillips Screwdriver Pipe Tape or pipe thread compound Safety Tips If you solder
More informationVACUUM VALVES AND HOSES
VACUUM VALVES AND HOSES 5046 Vacuum Valve Two-piece 500 F (260 C) industry standard 5255 Vacuum Valve Three-piece 500 F (260 C) industry standard SS5700 Stainless Steel Vacuum Valve Three-piece 1000 F
More informationPARTS CATALOGUE 2011
Lindstrand Hot Air Balloons Limited Maesbury Road, Oswestry Shropshire, SY10 8ZZ, U.K. Tel: +44 (0)1691 671717 Fax: +44 (0)1691 671122 sales@lindstrand.co.uk PARTS CATALOGUE 2011 INDEX PAGE 2: PAGE 3:
More informationMain Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents
Hoffman Specialty Regulators Main Steam How to Select Steam Model Radiator Convector Unit Thermostatlic Number (Angle Type) (Bottom Inlet) Heater Mains Vent (only) Remarks 1A X Adjustable Orifice 70A X
More informationInstructions. Certifications CH Chrome SS Stainless Steel. Single Handle, Industrial Style, Pull-Down Kitchen Faucet.
Instructions *Image may vary slightly from actual product Tools Required Adjustable Wrench Groove Joint Pliers Pipe Wrench Phillips Screwdriver Pipe Tape or pipe thread compound Safety Tips If you solder
More informationWAL-RICH CORPORATION SINCE 1950
STEAM SPECIALTIES ANGLE STEAM RADIATOR VALVES 0408102 1/2 1 10 0408104 3/4 1 6 0408002 1" 1 4 0408004 1 1/4" 1 2 0408006 1 1/2 1 2 - Brass - Imported STRAIGHT STEAM RADIATOR GATE VALVES 0409002 1" 1 4
More informationYALE Site Specifications AIR VENT SCHEDULE
SECTION 23 21 16 01 PIPING SPECIALTIES APPENDIX Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 AIR VENT SCHEDULE Tag AV-1 AV-2 AV-3 Type Automatic Float Low Pressure
More informationGeneral System Layout Sketch
General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems
More informationSuperKlean Washdown Products
February 2012 DURAMIX 8000 INSTALLATION AND MAINTENANCE INSTRUCTIONS **DO NOT THROW AWAY AFTER INSTALLATION** **SAVE AND DISPLAY PROMINENTLY WHERE THIS EQUIPMENT IS USED** WARNING HIGH PRESSURE AND HOT
More informationA. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.
SECTION 23 21 23 - HYDRONIC PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationINSTALLATION INSTRUCTIONS
,t_2007 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR 505,264M (65484504) 10/07 Supersedes 09/06 COILS n _putech blications ical Litho U.S.A. RETAIN THESE
More informationModels: GW/R-T GW/R-2-T GW/R-3-T
Part# GW/R-T-OM 1/12/04 TN Models: GW/R-T GW/R-2-T GW/R-3-T This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly
More informationISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO
ISO9001:2008 Cert. 403 Certified FIRE HYDRANTS SFFECO since www.sffeco.com DRY BARREL FIRE HYDRANT Meets all applicable parts of ANSI/AWWA C502 standard UL Listed (EX16453) and FM Approved (FM1510) 250
More informationTECHNICAL DATA. Wet 26a. February 22, 2009
February 22, 2009 Wet 26a 1. DESCRIPTION The Viking Alarm Check Valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping. The valve
More informationC 9000 Polymer Quick-Acting Safety Coupler Range
C 9000 Polymer Quick-Acting Safety Coupler Range C 9000 Polymer Quick-Acting Safety Couplers ISO B Profile 9401U Page -10 9405U Page -10 9414U Page -10 9410U Page -10 9421U Page -10 9416U Page -11 9440U
More informationUL/FM Fire Protection Products. Reliable fire protection products for your commercial, industrial, or institutional property.
UL/FM Fire Protection Products Reliable fire protection products for your commercial, industrial, or institutional property. Reliable UL/FM Fire Protection Products Markets Power Institutional Company
More informationGetz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System
Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System 1 Revised 11/18/10 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com LIMITED
More informationSeries 20 Dual Check Backflow Preventers
Series 20 Dual Check Backflow Preventers Excellence Matters Specify It! A Division of Watts Regulator Company 427 North Market Blvd Suite #9 Sacramento, CA 9584 Phone: 96-928-02 Fax: 96-928-9 www.amesfirewater.com
More informationMLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN
DIVISION 21 - FIRE SUPPRESSION (REFER TO SECTION 23 05 00 FOR BASIC FIRE SUPPRESSION REQUIREMENTS) 21 05 00 Common Work Results for Fire Suppression 21 13 13 Wet-Pipe Sprinkler Systems END OF SECTION FIRE
More informationWATER SUPPLY HOOK-UP DISPLAY 0-WSH-1
WATER SUPPLY HOOK-UP DISPLAY 0-WSH-1 A wide variety of angle stops and flex connectors in all the popular sizes, ranging from 9 to 60, are included in this 4 foot display. 9 SLOT FLEX RACK 10-0001 00/00/00
More informationWAL-RICH CORPORATION SINCE 1950
HOSES 3/8 ID DOUBLE FEMALE HOSE - BAGGED BAGGED# SIZE Box 0802002 3/4 FHT x 4' 1 25 0802004 3/4 FHT x 5' 1 25 0802006 3/4 FHT x 6' 1 25 0802008 3/4 FHT x 8' 1 25 0802010 3/4 FHT x 10' 1 25 0802012 3/4
More informationPage 1 of 18. Part# /5/2013
Part# 1002655-06 8/5/2013 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS
More informationA. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.
SECTION 23 70 00- CENTRAL HVAC EQUIPMENT PART 1: GENERAL 1.1 PURPOSE: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationVENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.
Main Steam How to Select Steam For Steam Vent selection information, please refer to Selection Guidelines on page 133. Model Radiator Convector Unit Thermostatlic Number (Angle Type) (Bottom Inlet) Heater
More informationRetro-DWS Other Methods Internal Heating Cable System for Sewer Pipe and Waste Drain Applications
Retro-DWS Other Methods Internal Heating Cable System for Sewer Pipe and Waste Drain Applications Installation Instructions Standard Cleanout Requiring Extension 4" example pg 3 3" example pg 5 Installing
More informationUniversity of Delaware
SECTION 23 21 23_HYDRONIC PIPING SYSTEMS ABOVE GRADE PART 1 GENERAL 1.1 SUMMARY University Contact: Energy & Engineering Group (302) 831-1744 This standard includes hydronic piping requirements for both
More informationParts & Material Included
O² Hydro Well System Installation, Use & Care Guide Parts & Material Included 1. Funnel 11. Drain Line 21. Air Head 2. Media Tank Distributer Tube 12. Air Release 22. Drain Fitting 3. Air Tank Distributer
More informationTOOLS & MISCELLANEOUS
TOOLS & MISCELLANEOUS 01-5095 251189 Sillcock Tee Handle, For 16 Broach Splined Stem, Fits Most Outside Hose Valves. 052151010056 01-5223 251199 4 Way Stem Key, Fits Square Stems 1/4, 9/32, 5/16, & 11/32.
More informationProtected with TechCoat finish. For Ceramic Tile Showers Cast iron Threaded for test nipple Extra heavy (.050) strainer DRAIN CONNECTION
QUICK CONNECT SHOWER DRAIN Protected with TechCoat finish Quick Clamping Gasket And Collar For Ceramic Tile Showers Cast Iron Clamping collar securely attaches drain to drain line Speeds installation Extra
More informationWASHER & DRYER REPAIR
WASHER & DRYER REPAIR Lasco # Description Lasco # Description Blish Mize SKU UPC Code Picture Blish Mize SKU UPC Code Picture 02-1371 5965355 3/4 Gasket For Hose Thread Connection, Rubber, Inlet Washer,
More informationKINNEY OIL MIST ELIMINATORS
KINNEY OIL MIST ELIMINATORS Models: A B, B1 & B2 C1 D & D1 Instruction Manual 1855-1 Revision 12/01 TABLE OF CONTENTS DESCRIPTION... 1 OPERATION... 1 ELEMENTS... 2 OIL RETURN METHODS... 3 DIRECT DRAIN
More informationSAN JUAN FRESH WATER COOLING SYSTEMS
SAN JUAN FRESH WATER COOLING SYSTEMS 4.3-5.7 GI VOLVO Block Only Cooling, Mounted Off Engine Kit #V-111 Installation Instructions San Juan Engineering Heat Exchangers provide thermostatically controlled
More informationBLASTMASTER 1600 CFM AIR DRYER
BLASTMASTER 600 CFM AIR DRYER PART NUMBERS AND SCHEMATICS GUIDE Company Profile Since 944, Marco has developed a strong tradition of providing innovative and reliable products and services to the surface
More informationTable of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company.
www.fetco.com Hot Water Dispensers User s Guide Maritime Versions Rated IP44 Table of Contents Contact Information... 2 Specifications... 2 Dimensions... 3 Installation... 4 Operating Instructions...6
More informationAPEX Water Filters MODEL RO 5. Treat your body to pure goodness with Apex filtered water INSTRUCTION MANUAL. pure water in every drop
APEX Water Filters pure water in every drop MODEL RO 5 INSTRUCTION MANUAL Treat your body to pure goodness with Apex filtered water A Water supply adapter valve B Cold water shut-off valve C Hot water
More informationB. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.
DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS
More informationI-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS I-VICFLEX.AB Victaulic VicFlex Style AB Sprinkler Fitting for Hat Furring Channel Ceiling Systems Read and understand all instructions before attempting to install any Victaulic
More informationHVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS
230500 HVAC BASIC MATERIAL AND METHODS PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 230000 Basic HVAC Requirements B. Section 230523 Valves C. Section 230510 Chilled
More information1. Division 23 Section "Steam and Condensate Heating Piping" for steam and condensate meters.
Page 230519-1 SECTION 230519 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationPotable Piping System
Page, May 2006 Potable Piping System BOW SUPERPEX is designed with three distinct layers for ultimate protection. The middle layer provides chlorine resistance as well as UV light exposure resistance plus
More informationDURA RIMP. Goodall Duracrimp coupling system: INFERNO ISO A and SUPER INFERNO. A safe crimping connection for our GOODALL steamhoses
Goodall Duracrimp coupling system: A safe crimping connection for our GOODALL steamhoses INFERNO ISO 6134-2A and SUPER INFERNO QUALITY SOLUTIONS DURA RIMP Content 1. Goodall DuraCrimp : A total solution
More informationModel F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers
Bulletin 060 Rev. A Bulletin 060 Rev. A Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers Features 1. Available in the following configurations: Pendent with standard escutcheon
More informationBarnes Oil Sensor Switch
Elevator sump basins Transformer vaults Leachate wells Garages Barnes BOSS Barnes Oil Sensor Switch Model BOSS BOSS PLUS RPM 3450 3450 Oil Water Switch Cord Length 10 10 Enclosure Rated Options Automatic
More informationHEATING- Heating Accessories RW List Prices Page X - 1. Bronze B&G Circulator Pumps. Iron Body Red Fox B&G Circulator Pump
Iron Body Red Fox B&G Circulator Pump A residential or light commercial, maintenance-free, in-line lead-free cast iron wet rotor circulator heating systems. HEATING- Heating Accessories RW List Prices
More informationUL/FM Fire Protection Products Setting the Standard
UL/FM Fire Protection Products Setting the Standard Markets Power Institutional Company Overview Mueller Co. is a leader in high-quality commercial and institutional fire protection products, offering
More informationPatterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationTeflon Rotary Drum Pump
Operating Instructions & Parts Manual 6005 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and
More informationUL/FM Fire Protection Products Setting the Standard
UL/FM Fire Protection Products Setting the Standard Markets Power Institutional Company Overview Mueller Canada is a leader in high-quality commercial and institutional fire protection products, offering
More informationTRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER
TRAINING BULLETIN TOOLS 1 May 27, 2011 1. DESCRIPTION Weight is approximately 30 lbs. Water 2½ gallons. Operating Pressure: 100 psi @ 70 degrees F. Note: Water expelled in 55 seconds. Stainless Steel Cylinder
More informationAudi-Larm Audible Alarm
Audi-Larm Audible Alarm MAINTENANCE AND REPAIR TAL 1706 (L) Rev. 7 MSA 2017 Prnt. Spec. 10000005389(I) Mat. 10093084 Doc. 10093084 REPLACEMENT KITS AND PARTS LIST TAL 1706 (L) Rev. 7-10093084 2 Exploded
More informationTroubleshooting the MPH 24FP Series Pedestal Hydrant
MAPA Products P.O. Box 129 Naples, Texas 75568 Toll Free: 877 897 2371 How the Hydrant Works: Troubleshooting the MPH 24FP Series Pedestal Hydrant The design of the hydrant assembly is based on a venturi
More informationSpare Parts List (Kits) Model Ref.:- HM35 SERIES A Spare Parts List (Kits) Issue 8 Dated 10-February-2015 Reference Drawing 09-1108-0000 Issue B Dated 07-January 2014 Drawing Ref. Part Number DESCRIPTION
More informationSECTION METERS AND GAGES FOR HVAC PIPING
SECTION 23 0519 METERS AND GAGES FOR HVAC PIPING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Thermometers. 2. Gages. 3. Test plugs. 4. Thermowells. 1.2 SUBMITTALS A. Product Data: For each type
More informationSettlement Agreement. Schedule 1: Covered Products
Settlement Agreement Schedule 1: Covered Products COVERED PRODUCT BRANDS BRASSCRAFT PLUMBSHOP PEERLESS SOLUTIONS MASTER PLUMBER COVERED PRODUCT CATEGORIES - WATER SUPPLIES SUPPLY STOPS WATER SUPPLY CONNECTORS
More informationPatterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationTechnical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved
Worldwide Contacts www.tyco-fire.com Model TJR Resilient-Seated Gate Valves Outside Screw and Yoke General Description TYCO Model TJR Resilient-Seated Gate Valves are used in Fire Protection Systems for
More informationCOMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6
OWNERS MANUAL BOSS COMPRESSED AIR DRYER Distributed by Air & Vacuum Process, Inc. Phone: 281-866-9700 Fax: 281-866-9717 Email: sales@airvacuumprocess.com SAFETY... Page 2 MAINTENANCE... Page 5 INSTALLATION...
More informationTECHNICAL DATA OBSOLETE
October 10, 2008 Deluge Devices 281a 1. PRODUCT DESCRIPTION The Viking Model C-1 is a rate-of-rise releasing device for use on hydraulic and pneumatic release systems controlling operation of Viking deluge
More informationDrinking Water Purification Systems
supersedes 200695Cx-2i&o SEAGULL IV X-2KB and X-2KF Drinking Water Purification Systems SEAGULL IV X-2KB SEAGULL IV X-2KF INSTALLATION AND PRODUCT USE GUIDE INSTALLATION INSTRUCTIONS NOTE: Read instructions
More informationGroup 35 Drainage System. This group contains information on the holding tanks. equipment applied to the coach. ...Sink and Shower Strainers
Group 5 Drainage System GENERAL: This group contains information on the holding tanks and drainage system. It also covers any waste destruction equipment applied to the coach. SPECIFICS: As applicable...drain
More information568X, 587X, 588X Series
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationHarvey Chemiclave EC Series Sterilizers
BARNSTEAD THERMOLYNE CORPORATION CHEMICLAVE EC SERIES STERILIZERS Harvey Chemiclave EC Series Sterilizers PARTS CATALOG LT1121x 12/10/98 1 Final Assembly - Refer to Figure 1 Figure Page 1 Final Assembly
More informationHEATING- Heating Accessories RW List Prices Page X - 1. Iron Body Red Fox B&G Circulator Pump. Bronze B&G Circulator Pumps
HEATING- Heating Accessories RW List Prices Page X - 1 Iron Body Red Fox B&G Circulator Pump A residential or light commercial, maintenance-free, in-line lead-free cast iron wet rotor circulator heating
More informationTECHNICAL DATA. model c-2
Page 1 of 6 1. PRODUCT DESCRIPTION The Viking Model C-2 is a rate-of-rise releasing device for use on hydraulic and pneumatic release systems controlling operation of Viking deluge valves on deluge or
More informationDesign and Construction Standards SECTION PLUMBING EQUIPMENT
SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES
More informationWest District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8
City of Ottawa Project No. CR006230 Page 1 of 8 PART 1 - GENERAL 1.1 Reference Standards.1 Conform to the following:.1 Provincial and municipal building and fire regulations as approved by Provincial Fire
More informationFLECK 5600 WATER SOFTENER INSTALLATION
FLECK 5600 WATER SOFTENER INSTALLATION Discount Water Softeners recommends using a licensed plumber to install your water softener. The following installation instructions are for use with the water softener
More informationDIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES
DIVISION 21 FIRE SUPPRESSION PART 1 GENERAL 1.01 DESCRIPTION A. Provide UL listed, FM approved listed fire protection specialties or accessories as required by either the equipment manufacturer or the
More informationThe Safest Connections...
The Fluid Manager The Safest Connections... The Lutz Accessory Range for Electrical & Pneumatic Drum, Tote and Container Pumps A c c e s s o r y R a n g e Accessory Range Safety is our Concern At a glance
More informationWM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis
WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis Installation And Service Manual Watts Pure Water 1725 W. Williams Dr. C-20., Phoenix, Arizona 85027 Phone: 888-774-7405 Fax: 602-588-0356 www.wattspurewater.com
More informationGETZ MANUFACTURING PART NO.: MODEL: SV1 100 PR VACUFILL SYSTEM (Revised 6/7/05)
GETZ MANUFACTURING PART NO.: 58616 MODEL: SV1 100 PR VACUFILL SYSTEM (Revised 6/7/05) GETZ SV1-100-PR VACU-FILL SYSTEM TABLE OF CONTENTS PAGE # 1... GETZ SV1-100-PR VACU-FILL SYSTEM 2... PARTS LIST 3...
More informationGETZ EQUIPMENT INNOVATORS PART NO.: 9G58619 MODEL: SV1 150 PR VACUFILL SYSTEM (Revised 2/25/14)
GETZ EQUIPMENT INNOVATORS PART NO.: 9G58619 MODEL: SV1 150 PR VACUFILL SYSTEM (Revised 2/25/14) !!WARNING!! SEVERE DAMAGE AND/OR INJURY MAY RESULT DO NOT DISCHARGE ANY EXTINGUISHER CYLINDER EXCEEDING 195
More informationGAS/OIL. 78 Section Assembly. 152 Discontinued Service Parts
78 Section Assembly 152 Discontinued Service Parts 78 Section Assembly Part Description Mfr. s Part A 315700059 FRONT SECTION 80 P. S. I. 7813 315700120 INTERMEDIATE SECTION, REGULAR 80 P.S. I. 7815 B
More informationHusky Diaphragm Pump Suction Kits
First choice when quality counts. Husky Diaphragm Pump Suction Kits H B E C A D COMPONENTS E F Air-Powered Pump Packages for a Variety of Fluid Containers 2-461 When it Comes to Suction Kit Packages We
More informationFleck 2510 Sediment Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com Fleck 2510 Sediment Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationModel G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler
UL Quick Response FM Standard Response ½ (13mm) Cover plate Adjustment Features 1. Flat cover plate with threaded attachment. 2. Solid or perforated cover plate available in chrome and white as Standard
More informationCubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM
SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for
More informationFleck 5600 Carbon Filter Installation & Start Up Guide
Clean Water Made Easy www.cleanwaterstore.com Fleck 5600 Carbon Filter Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationEFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08
EFFECTIVE: MAY, 2008 American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 05/08 021-0061 Model: ASQ Glasswasher American Dish Service
More informationOetiker Stepless TM Ear Clamps
WaterRise Water Shut-Off u Premade to save you time and money u Self-contained in tough PVC case u Insulation and heating cable protect against the cold u All copper pipe and rugged Mueller valves u 5-year
More informationB. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationTechnical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT
Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT
More information569, 570, 571, 572 Series
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationRevised 9/05. Model X-750 Subassembly Parts List
Revised /0 Model Subassembly Parts List Blade Belt Tensioner 0 PART NUMBER DESCRIPTION QTY. -G0-0-0 SHSB, / x / -G0-0-0 SHSB, / x / -X-0-00 Arm, Belt Tensioner -G0-0-00 Washer, Flat /" -0-0-0 Washer, Split
More informationEssex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL
Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 SECTION 232116 - HYDRONIC PIPING SPECIALTIES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions
More informationFlow Control for Fire Protection
Flow Control for Fire Protection Valve Solutions From An Industry Leader AmesFireWater.com Count on the Fire Protection Leader for Reliable Flow Control Solutions Ames provides a range of high-quality
More information569, 570, 571, 572 Series
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationArmstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual
Armstrong J Series, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual This bulletin should be used by experienced personnel as a guide to the installation
More informationFlow Control for Fire Protection
Flow Control for Fire Protection Valve Solutions From An Industry Leader AmesFireWater.com Count on the Fire Protection Leader for Reliable Flow Control Solutions Ames provides a range of high-quality
More informationModel ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description
Technical Services 800-381-9312 +1-401-781-8220 www.tyco-fire.com Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description The TYCO Model ESFR-17 Dry
More informationVM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" THERMAL CUT-OUT THERMAL TRIP PLUG
VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" 700300-013 2. THERMAL CUT-OUT 409560-001 THERMAL TRIP PLUG 409210-010 3. HEATER TERMINAL COVER VM99 2-4 HEATER TERMINAL
More informationGas Range Catalogue. Tel: +44 (0) Fax: +44 (0) Website:
Gas Range Catalogue by NEW PRODUCT! Hob Mate Manufactured to EN 15266 CSST Corrugated Stainless Steel Tube Online Videos Available The Hob Mate has been specifically designed to provide a fast and efficient
More informationA HEATER KIT With Diesel Engine Connection Fittings
A-12142 HEATER KIT With Diesel Engine Connection Fittings Figure 1 (General Layout and Parts I.D.) Page 1 of 6 Read these instructions and identify all components. Please retain these instructions for
More informationPart#: 26B113 HEAVY DUTY CAST IRON ROTARY DRUM PUMP
Part#: 26B113 Part # 26B113 Description HEAVY DUTY CAST IRON ROTARY DRUM PUMP Operating Instructions & Parts Manual Please read and save these instructions. Read carefully before attempting to assemble,