1 PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible. Easy; significantly shorter assembly and installation times. Economical; extremely high efficiency and good penetration of acoustical obstacles significantly reduce the required number of sounders. IP 66 IK C 40 C EN 54-3 VdS UL 10 Years Schutzart impact-proof housing operating temperature acoustic penetration external tone selection V DC V DC warranty PRODUCT PA 10 PA 20 DATA Operating range V V V V V V AC Hz DC AC Hz DC Nominal current consumption ma ma ma ma ma ma Sound pressure level 110 db(a) 120 db(a) Sound level reduction max. 12 db via potentiometer Alarm tones 80 / 4 tones are externally selectable Duty cycle 100 % Operating temperature 40 C C Storage temperature 40 C C Relative humidity 90 % Protection system according to EN 6052 IP 66 Protection class II Material PC / ABS blend similar to RAL 3000 (flame red) RAL 7035 (light grey) RAL 9003 (signal white) Cable entry 5x M20 knock-outs on side, 1 knock-out on back Integrated seal with cable entry 6 13 mm (feed-through grommet) Connecting terminals 2.5 mm 2 fine wire with cable end sleeve, AWG 16 Weight 1,060 g 1,050 g 1,200 g 1,090 g 1 Power consumption dependent on operating voltage. OPTIONS/ACCESSORIES I lim t Enclosure fitting Surface gasket Tamperproof sealing Panel mounting kit
2 DIMENSIONS PA 10 PA Ø Ø 9 M20 prepared M20 prepared AUDIBLE SIGNALING DEVICES ARTICLE PA 10 PA 20 VERSION RATED VOLTAGE V AC 24 V AC V DC V AC 24 V AC V DC Standard housing red GL/MED housing red Standard housing grey GL/MED housing grey Article numbers for other voltages and versions on request. ARTICLE PA 10 PA 20 Enclosure fitting For connection (daisy-chaining) of several sounders of the PATROL series Surface gasket Tamper-proof sealing (pack of 4) Panel mount installation kit PATROL Sealing of the sounder installation surface when, e. g. cable entry is executed from the back. Anti-tamper sealing for fasteners of the PATROL devices after installation in order to prevent manipulation of the devices. The PATROL devices are also suitable for panel mounting. This kit consists of a plug connector for the electrical contact, as well as all installation materials
3 PRODUCTS AUDIBLE SIGNALING DEVICES TONE TABLE 15 evacuation alarm Netherlands NEN evacuation alarm Australia AS NFPA 775 Hz Pulsating tone, Australien alert AS1670, ISO , (fast), IMO 3d, Germany KTA3901 evacuation alarm Hz 65, Sweden SS (all-clear signal) 66 67, Germany KTA3901 (all-clear signal) Hz PFEER (general alarm), UK BS (back-up alarm) PFEER (general alarm) Hz 10 s 40 s 10 s Hz Hz 54, Finland (all-clear signal) 1 55, PFEER gas alarm Sweden SS (local warning) 103 Sweden SS (air raid warning) Sweden SS (emergency signal) 107 Germany KTA3901 (evacuation alarm) 420 Hz 109 Australia AS2220, AS1610, AS (fast variable), bell 111 ISO8201 (emergency evacuation signal), USA (evacuation alarm) 470 Hz 112 ISO8201 (emergency evacuation signal) 113 ISO8201 (emergency evacuation signal), sweeping 7s 7s 4 ms 0,7 s Sweden SS (important message (pre-mess)) 4 ms Hz 680 Hz Sweden SS (emergency signal) (fast), Horn Hz Hz Hz 1 P FA N N E N B E R G. C O M 61, general alarm Finland 46 0,85 s 422 Hz 3,75 s (medium), UK BS ,5 s 1600 Hz (fast), UK BS ,6 s, France NFC (fast) 0,3 s 60 0,3 s 0,875 s 0,875 s 13 s 6,5 s 1,8 s 1,8 s 150 ms 150 ms 900 Hz Hz 0,75 s 0,625 s 0,625 s 1450 Hz 0,69 ms 2850 Hz 970 Hz 59 (fast), UK BS Hz 57 fire alarm, UK BS Sawtooth, DIN tone Germany (emergency signal), PFEER PTAP no tone 2 1
4 0, TONE TABLE IMO (telephone call) IMO (leave ship) IMO SOLAS III/50 + SOLAS III/6.4 (general alarm) 122 Alternating tone 123 Alternating tone 124 Singapore 125 Alternating tone 128 Alternating tone 130 UK BS (fire alarm) CONTROL OF THE TONES s s 0.25 s 2000 Hz 0.5 s 3 s 0.5 s 2,5 s 7 s 1025 Hz 2,5 s 0.25 s 0.25 s 2400 Hz 0.5 s 0.25 s EN s 0.25 s s s 1025 Hz DIP-SWITCH EXTERNAL TONE SELECTION (SETTING OF BASIC TONE) C1 C2 C1+C BASIC TONE TONE ON 2 * ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON * factory setting UK BS (fire alarm, railway crossing) UK BS (fire alarm, increased urgency railway crossing) 142 Alternating tone Alternating tone France NFS (fire alarm) Sweden SS Sweden SS Alternating tone (two tone chime) 900 Hz 650 Hz 0,4 s 650 Hz 2 s DIP-SWITCH EXTERNAL TONE SELECTION (SETTING OF BASIC TONE) C1 C2 C1+C BASIC TONE TONE ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON AUDIBLE SIGNALING DEVICES
5 PRODUCTS AUDIBLE SIGNALING DEVICES CONNECTION DIAGRAM X2 -L -L +N +N C1 C2 C1 C2 electrical connection and tone selection through external control of C1 and C2 operating voltage connection N - L + AC: DC: DC + - S2 S2 (by-passing the reverse polarity protection diode) with reverse polarity protection (factory setting) without reverse polarity protection + - AC S3 S1 volume control Note: In order to conform to EN54-3, the volume control must be set to the maximum position S3 tone selection switch S1 (selection of the polarity of the control voltage for C1 and C2) factory setting + CONFORMITY TO STANDARDS The acoustic parameters conform to the European standard DIN EN ISO 7731: Ergonomic alarms for public areas and workplaces acoustic alarms. The requirement for an acoustic alarm signal can be found in the harmonised standards: EN Electrical equipment of machines EN Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 08
PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5
PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.
More informationMulti Tone Alarm Sounders A
Multi Tone Alarm Sounders A S I G N A L G E R Ä T E Size 2 Size 3 Size 4 ASS-P ASS-T ASM ASL ASX 103 db 108 db 113 db 120 db 127 db 8 tones 32 tones 32 tones 63 tones 63 tones Features w Comprehensive
More informationNexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon
Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon Technical Specification 1. Sounder Supply Voltage Range 10-60V DC Current 0.12 0.55A* (Typ. 0.5A @ 24V,
More informationPRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10
PRODUCT INFORMATION PI 38.43 Sounder SG 200 Page 1 of 10 Table of Contents 1. Product Description............................... 3 2. Features......................................... 3 3. Functional Description............................
More informationINSTRUCTION & SERVICE MANUAL
INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following
More informationExplosion Proof Combination Signal db (A) / 5 Joule
Explosion Proof Combination Signal - Operating instructions Additional languages www.r-stahl.com General information Contents 1 General information...2 1.1 Manufacturer...2 1.2 Information regarding the
More informationINSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas
INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas UL 1203 CSA C22.2 NO. 30-M1986 The D1xS1 and D1xS2 Alarm Horns also comply with the following standards for signaling
More informationX10 Mini, Midi & Maxi
Industrial Sounder, Sounder Beacon X0 Mini, Midi & Maxi Installation Manual EAT X0 Mini, Midi & Maxi Installation Manual (90F) Contents Overview and purpose... Product assembly... Select wiring method......
More informationAP200 SERIES INTELLIGENT ALARM DEVICES
Tech Data Sheet D017GB1 Fire Detection /01 AP00 SERIES INTELLIGENT ALARM DEVICES Intelligent AP00 series alarm devices for FX NET fire detection system The intelligent AP00 series alarm devices are used
More informationE2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.
E2S Datasheet 1.2.1 v10a ISmA1 ISminialarm The ISmA1 is a compact, 100dB(A) alarm sounder. Approvals include ATEX, IECEx and GOSTR for Zone 0 applications and FM approval for Class I Division 1 and Class
More informationINSTRUCTION & SERVICE MANUAL
INSTRUCTION & SERVICE MANUAL D1xC COMBINED RADIAL HORNS & STROBES For Use In Hazardous Locations - Gas 3) Ratings and Markings The D1xC1 and D1xC2 combined alarm horns and strobes comply with the following
More informationAP200 SERIES INTELLIGENT ALARM DEVICES
Tech Data Sheet D0170GB Fire Detection /01 AP00 SERIES INTELLIGENT ALARM DEVICES Intelligent AP00 series alarm devices for FX fire detection system The intelligent AP00 series alarm devices are used in
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT
More informationProduct Manual Standard Asserta Sounder Range
Product Manual Standard Asserta Sounder Range Document Structure: Steve Martin - 18/09/08 Technical Information: Chris Anderson - 14/10/08 Cooper Fulleon Ltd Llantarnam Park Cwmbran South Wales NP44 3AW
More informationE2S Datasheet v10a
E2S Datasheet 1.2.3 v10a ISmC1 ISminialert The ISmC1 is a compact combined 100dB(A) alarm sounder and L.E.D. beacon only one Zener barrier or galvanic isolator required to run both sounder & beacon or
More informationINSTRUCTION MANUAL (ATEX)
INSTRUCTION MANUAL (ATEX) ISmA1M Minialarm Intrinsically Safe Round ISmA1M Volume Control Tone Generator S3 Tone Selection Switches Fig 1 Simplified block diagram The ISmA1M sounder is CE marked for compliance
More informationINSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder
INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder 1) Introduction The Appello tone and speech annunciation sounder has three different styles in AC and DC. A105NAPPX
More informationSignaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.
Signaling Devices Acoustic Signaling Devices 28 Optical Signaling Devices 30 26 Signaling Devices Acoustic Signaling Devices Acoustic Signaling Devices MSS300-SA SG 200 DS 10 LSN/GLT GLT GLT GLT Operating
More informationXenex Conventional Fire Detection & Alarm System
SECTI 4: page 1 Section 4: Xenex Conventional Fire Detection & Alarm System SECTI 4: page 3 Xenex system architecture Beam Transmitter Beam Receiver End of Line Call Point Smoke Detector Smoke Detector
More information4) Intrinsic Safety Certification
INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for
More informationBulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices
Bulb Overview PART NO. DESCRIPTION TOTAL LENGTH(mm) VOLTAGE FOR USE WITH: 955 840 34 Bulb BA15d 5 W 42 12 V 200 203 209 641 800 840 845 955 840 35 Bulb BA15d 5 W 42 24 V 200 203 209 641 800 840 845 955
More informationINSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder
AUTHORIZED DISTRIBUTOR ControlSystemsUSA.com Houston, Texas USA sales@controlsystemsusa.com 832-615-3588 INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder
More informationVIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm
VIMPEX Sounder Range Fire Alarms Banshee Electronic Sounders FlashDome EN 54-3 Evacuation Audible Alarm BS 5839-1 Beacons The range of sounders, beacons, sounder beacons and accessories represents the
More informationConventional Fire Detection
SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct
More informationOptical-Audible Signal Devices
Overview LED/Buzzer Combination LED/Multi-Tone er Combination 150 Installation model 450 Installation model with acknowledgement funcition 450 Installation model for AS- Interface 420 Base mounting 422
More informationOPERATING AND INSTALLATION
A division of Signature Ind. Ltd YO6 YL6 V6 DIMENSIONS (mm) 280mm 11 OPERATING AND INSTALLATION INSTRUCTIONS FOR (UL & ATEX) YODALEX FLAMEPROOF AUDIBLE AND VISUAL ALARMS D7292 OPERATING CLASS 1 DIVISION
More informationSegnalatori acustici AW-ETH12MD AW-ETH12MD audible warning
Segnalatori acustici audible warning devices I segnalatori acustici, sono utilizzati in ambienti a basso rumore di fondo, ove sia presente una potenziale atmosfera esplosiva. Sono dotati di circuito a
More informationVTG-32E Spatial Sounder 24Vdc EN54 part 3 approved
The VTG32E family of sounders have been designed to cover a wide spectrum of applications. The 24 volt EN543 approved version is for use with conventional fire alarm systems including SAVWIRE two wire
More informationATEX. IECEx. culs GOST-R. VdS
1. Hazardous Area Signalling 1.11 Intrinsic safety: Visual 1.12 Intrinsic safety: Audible 1.13 Intrinsic safety: Combination 1.14 Intrinsic safety: Manual Call Points 1.21 Explosion / flame proof: Visual
More informationSonos-SB Siren/Beacon
Sonos-SB Siren/Beacon Audible/optical signal transmitter compliant with EN 54-3 and EN 54-23 for fire alarm systems, in red and white. Wall mounting (category W) and ceiling mounting (category C) for indoor
More informationGRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S
www.stahl.de > Corrosion resistant omnidirectional high output sounder > Integrated Ex d enclosure > Extreme temperature range > 3 stage alarm with independant tone selection for V DC systems > IP66 IP67
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExTS110D Flameproof Sontel 1) Introduction The BExTS110D is a flameproof Sontel telephone sounder which is certified to the meet the requirements of the ATEX directive
More informationInstallation Instructions for W2H Series Signals
Installation Instructions for W2H Series Signals IF1513 A Description and Operation DIMENSIONS W2H A 8 7/8" (225 mm) B 8 1/4" (210 mm) C 13" (330 mm) Figure 1. Speaker/Amplifier Dimensions The W2H signaling
More informationSegnalatori acustici AW-ETH20MD Audible warning devices
Segnalatori acustici Audible warning devices I segnalatori acustici sono utilizzati in ambienti aperti ad alto rumore di fondo, ove sia presente una potenziale atmosfera esplosiva. Sono dotati di circuito
More informationELECTRONIC SOUNDER STROBE Model : AVD-C407
ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an
More informationYO3 - YO4 / YL4 - YO5 / YL5
C l i f f o r d & S n e l l YO3IS YO4IS DIMENSIONS mm 81(3.2 ) 90(3.5 ) YO3 - YO4 / YL4 - YO5 / YL5 Intrinsically Safe Audible and Visual Alarms ATEX YO5IS YL4IS YL5IS 90(3.5 ) 81(3.2 ) MAIN FEATURES BASEEFA
More informationXP95 Sounder VAD Base
PP2478/2016/Issue 5 XP95 Sounder VAD Base FUNC TION The XP95 Sounder Visual Alarm Device (VAD) Bases incorporates a standard mouting base with a loop-powered sounder VAD. It is used to signal a fire alarm
More informationFlex-Tone Explosionproof Electronic Signals ETH655 & ETH855 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Installation
Flex-Tone Explosionproof Electronic Signals ETH655 & ETH855 Installation & Maintenance Information IF 1494 SAVE THESE INSTRUCTIS FOR FUTURE REFERENCE Description and Operation Cooper Crouse-Hinds Hazardous
More informationLC1 Modular Ceiling Loudspeaker Range. en Installation note
LC1 Modular Ceiling Loudspeaker en Installation note LC1 Modular Ceiling Loudspeaker Table of Contents en 3 Table of contents 1 System Overview 4 1.1 Housings 4 1.2 Loudspeakers 5 1.3 Accessories 6 2
More informationInterface and EOL Modules 8
Interface and EOL Modules Interface Modules Series 420 25 Interface Modules Series 100 291 EOL Modules 293 254 Interface and EOL Modules Interface Modules Series 420 Interface Modules Serie 420 Interface
More informationAuer - Signal tower ECO Ø70 mm modular
products Panel Signalling Signal Towers - Auer Auer - Signal tower ECO Ø70 mm modular Modular system with bayonet fitting for quick assembly LED or conventional filament lamp for cost sensitive applications
More informationEngineering Guideline. pac- Carriers Type Universal
Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art
More informationAUDIBLE SIGNALIZATION
01 SIGNALIZATION AUDIBLE SIGNALIZATION PROGRAMMABLE ELECTRONIC MULTITONE SIRENS WITH TWO INPUTS Specially designed for marine application With two inputs where using each one, different tones and frequency
More informationElectronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21
Electronic Standard Devices Annunciator Relay MR and MRE MR 2 and MRE 2 The products described in this brochure are intended for industrial use and meet the requirements laid down by the EU directive 7
More informationSELECT-A-HORN/STROBE SERIES
SELECT-A-HORN/STROBE SERIES Features Description Mircom s Select-A-Strobe/Horn Series is designed to comply with the Americans with Disability Act (ADA) and meet UL standard 1971 requirements for emergency
More informationDB5 Intrinsically Safe Sounder Type DB-5
Operating Instructions RTK Instruments Limited DB5 Intrinsically Safe Sounder Type DB-5 Description The DB5 Sounder is a strong, lightweight warning sounder, CENELEC certified to Ex II 1G EExia IIC T4
More informationLB3-PCx50 Premium Cabinet Loudspeakers
Communications Systems LB3-PCx Premium Cabinet s LB3-PCx Premium Cabinet s High quality music and speech reproduction Weatherized, suited for sheltered outside use Prepared for Bosch WLS, EOL and DMY pcb
More informationEX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL
PRODUCT NAME: SD-100-1- WEATHER-PROOF SOUNDER/HORN DOC NO.: EX-TECH SIGNALLING SAS-12-SD100-1-TM REV03 WEATHERPROOF SOUNDER/HORN IP66 SD-100 SERIES EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN
More informationIntellia Sounder Bases and Sounder Beacon Bases
Intellia Bases and Beacon Bases The Base and Beacon Base are a local-area alarm devices designed for indoor use. They can be connected only to detection systems using Intellia detectors and FX control
More informationYodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon
Sounders Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon Pg 185 186 187 188 189 190 191 Y03 1YA030207 1YA030203 1YA030205 YL030/24 A1:2002 YL030110/230 UL464 C22.2 No. M1983 BS
More informationTechnical Manual for the Horn DB1P UL DB1HP UL
Technical Manual for the Horn DB1P UL DB1HP UL Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibility for damage, loss or expense
More informationThe Use of Public Address System to Improve Tunnel Safety - Current Practices. Lim Hock Tay
The Use of Public Address System to Improve Tunnel Safety - Current Practices Lim Hock Tay Content 1 Introduction 2 3 Overview of Survey Responses Discussion 4 Conclusion PIARC International Conference
More informationPart Number Structure ZA 016 L D CT
Product Application Guide- 22mm Industrial Alarms with Terminal Block Part Number Structure ZA 016 L D CT Series: ZA = 22mm Maximum Voltage: 016 = 6-16; 028 = 16-28; 048 = 28-48; 120 = 48-120 Sound Level:
More informationAudible warning devices for external alarm
VdS SCHADENVERHÜTUNG VdS Publisher: Gesamtverband der Deutschen Versicherungswirtschaft e.v. (GDV) Büro Schadenverhütung Publishing house: VdS Schadenverhütung Rules for Intruder Alarm Systems Audible
More informationAnnunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology
Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21 Power Station Control Systems Power Distribution Control Systems Control Room Technology Automation Equipment The products described in this brochure
More informationSOUNDER BASES AND SOUNDER BEACON BASES
Tech Data Sheet D01513GB3 44/2011 Fire Detection SOUNDR BASS AND SOUNDR BACON BASS Intellia Sounder Bases and Sounder Beacon Bases The Sounder Base and Sounder Beacon Base are a local-area alarm devices
More informationPolyGard 2-channel Gas Controller MGC-03
PolyGard 2-channel Gas Controller MGC-03 DESCRIPTION Gas measuring and monitoring controller based on state-ofthe-art micro-technology with integrated buzzer for continuous monitoring of the ambient air
More informationConventional Audible Visual Range
Conventional Audible Visual Range Visual Devices Non-Addressable Audible Visual Devices Base Sounder Honeywell s conventional audible visual devices operate over a wide input voltage range of 9 to 33VDC
More informationDB1 Range - HORNS - Up to 103 db(a)
DB1 Range - HORNS - Up to 103 db(a) Explosion-proof, Weatherproof Features UL listed Class I, Div. 1, Groups C & D. Class 1, Zone 1. ATEX approved. NEMA 4x, IP66. Certified temperature: 13 F to +158 F.
More informationEngineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules
Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional
More informationHalf-Dome. the Design-Tower. Compact
the Design-Tower 81 Compact 82 compact signal towers Visual-audible LED signal tower system in semicircular design Modern signal tower design Available to order pre-configured or with customised tower
More informationDICTATOR Hold-Open Systems for Hazardous Areas
DICTATOR for Hazardous Areas Products to be used in hazardous areas obviously have to meet special demands. The European ATEX directives (first the EN 94/9/EG and then the directive 2014/34/ EU) brought
More informationMulti-Gas-Controller MGC2
Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants
More informationDEB71. Earth Leakage Monitoring Relay. Benefits. Description
Earth Leakage Monitoring Relay Benefits Adjustable trip level. Adjustable leakage threshold from 30mA to 5A or from 300mA to 30A. 2 outputs. Two relay outputs provide, besides the alarm signal an additional
More informationFire Signalling. Signalling Solutions
Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.
More informationInstallation and user manual for the BiWire / Conventional Repeater Panel
Panel EFBWCV-REPEATER Contents Introduction.... 3 Purpose... 3 The Panel.... 3 Indication Equipment (IE).... 3 Power Supply Equipment (PSE).... 4 System Wiring.... 5 Status Indications.... 5 Repeater I/O....
More informationTechnical Manual for the Horn - DB1PUL DB1HP UL
Technical Manual for the Horn - DB1PUL DB1HP UL Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibility for damage, loss or
More informationTrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions
TrueAlert NonAddressable, MultiCandela Notification Appliances Installation Instructions PRODUCT IDENTIFICATION REFERENCE (See Page 4 for Detailed Product Specifications) Type Mount Model Color Operation
More informationAddressable Detectors & Bases
Edwards Signaling Catalog u Intelligent Initiating Addressable Detectors & Bases Detectors: E-PD, E-PHD, E-HD Bases: B4U, RB4U, IB4U, SB4U Overview Edwards intelligent addressable detectors are meticulously
More informationUniversal fault annunciator for panel mounting
Universal fault annunciator for panel mounting Communication over Ethernet USM - Universal-fault annunciator for panel mounting Low depth housing for panel mounting Versions with 8, 16, 32 or 48 inputs
More informationThe EN54 Part 2 and 4 Fire System
Scope of work: To design, supply, install and commission a Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54 Part 2 and 4 Fire
More informationSmoke and Fire Curtains
Smoke and Fire Curtains NFPA UL Datasheet firecurtaintech.com SMOKE AND FIRE CURTAINS Fire Curtain Technologies distributes a wide range of fire and smoke protective curtains to protect every type of building
More informationPart Number Structure ZT 028 L D CT R 15
Product Application Guide- 22mm Industrial Alarms with LED Lights Part Number Structure ZT 028 L D CT R 15 Series: ZT = 22mm with LED Maximum Voltage: 016 = 9-16; 028 = 20-28; 120 = 48-120 Sound Level:
More informationQAF63.2-J QAF63.6-J. Frost detectors. for use on the air side
s Frost detectors for use on the air side QAF63.2-J QAF63.6-J Active capillary tube sensor for acquiring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10
More informationL-Series, Indoor Strobes and Horn Strobes
Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Strobes/Horn Strobes for Ceiling Applications General The L-Series audible visible notification products offer
More informationSERIES 65 ENGINEERING PRODUCT GUIDE
SERIES 65 ENGINEERING PRODUCT GUIDE Wide Voltage Conventional Detectors Series 65 incorporates well-proven sensing technologies, including an Integrated Circuit based on that used in XP95 analogue addressable
More informationPhotoelectric sensors W27-3, Photoelectric proximity sensor, Background suppression
ONLINE DATA SHEET www.mysick.com Photoelectric sensors W27-3, Photoelectric proximity sensor, Background suppression WTB27-3K2411 Photoelectric sensors W27-3, Photoelectric proximity sensor, Background
More informationXUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12
Characteristics photo-electric sensor - XUX - multi - Sn 0..40m - 12..24VDC - M12 Complementary Enclosure material Lens material Maximum sensing distance Output type Add on output Status LED [Us] rated
More informationANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual
ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual From urgent alarms to routine messages, the PD141AFO VIGILANTE handles all types of operational messages with simplicity and economy. The VIGILANTE
More informationRoom Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature
1 858 1858P01 1858P02 1859P02 Symaro Room Sensors for relative humidity (high accuracy) and temperature AQF3150 QFA31 Use Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 4 20 ma for r h and
More informationSIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics
by Tomar Electronics SIRENS POWER ALARM PROGRAMMABLE MULTI-SOUND INDUSTRIAL SIGNALS The POWER ALARM siren is a heavy duty industrial audible alarm designed to operate under adverse industrial conditions
More informationQAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products
1 821 1821P01 Frost sensors for use on the air side Active capillary tube sensor for measuring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10 V Use On
More informationLF-4000 Series Conventional Fire Alarm Control Unit
LF-4000 Series Conventional Fire Alarm Control Unit Features: 1 to 36 Zone Control Panels Control Key Switch Easy Push Button Control Switches Zone Circuit Monitoring for Open and Short Sounder Circuit
More informationELECTRONIC PARTS - CATALOGUE
Smoke and Heat Ventilation Pneumatic - Electronic Control Systems K + G Pneumatik GmbH In der Krause 48 52249 Eschweiler Germany. +49 (0) 24 03 / 99 50-0 ; +49 (0) 24 03 / 655 30 Grasl Pneumatic-Mechanik
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationQuick Selection Guide Fire Systems LSN Periphery
Local SecurityNetwork Easy wiring Auto configuration capability (self-learning mode) Central programming of all device configurations from the panel Flexible network structure (Loop, stub, T-tap & mixed
More informationPD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual
PD154 & PD158 VIGILANTE II ANNUNCIATORS 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal Power
More informationINSTRUCTION MANUAL A131 High Level Audible Warning System
Weight: 1.5kg single AC unit 2.9kg four way AC unit Marking: 3) Installation Requirements 1) Introduction The A131 high level audible warning system is an effective wide area warning alarm system and can
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm
More informationDSE ELECTRONIC SIRENS Advantages & Functions
DSE ELECTRONIC SIRENS Advantages & Functions DSE ELECTRONIC SIRENS These modern, high-powered warning sirens are used to warn people of ecological, military, terrorist, catastrophic and other hazards.
More informationDipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Phone: 040 807-0 Fax: 040 807-259 Alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC display
More informationWIDE RANGE SPEAKER INSTRUCTION MANUAL TABLE OF CONTENTS
INSTRUCTION MANUAL WIDE RANGE SPEAKER CS-64BS TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION AND FEATURES... 3 3. IMPEDANCE CHANGE... 3 4. WIRING 4.1. When No Bridge Connection is
More informationMore Precision. indusensor // Linear inductive displacement sensors
More Precision indusensor // Linear inductive displacement sensors 4 Gauges with external controller indusensor LVDT - Proven LVDT technology - Measuring ranges ±1 ±10mm - Excellent price/performance ratio,
More informationIndustrial Signalling
Industrial Signalling Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place. Product Range
More informationINSTRUCTION MANUAL TABLE OF CONTENTS
INSTRUCTION MANUAL WIDE RANGE SPEAKER CS-154BS TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION AND FEATURES... 3 3. IMPEDANCE CHANGE... 4 4. WIRING 4.1. When No Bridge Connection is
More informationRemote alarm indicator and test combination MK2430
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Tel.: 040 807-0 Fax: 040 807-259 Remote alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC
More informationBL 200 Strobes. Page F.01U A1.en/ 6/2/2004 ST / PMF1 / zab
PRODUCT INFORMATION BL 200 Strobes Page 1 601- F.01U.000.862 A1.en/ 6/2/2004 ST / PMF1 / zab Table of Contents 1. Product Description............................... 2 2. Features.........................................
More informationL-Series, Indoor Strobes and Horn Strobes
Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Horns, Strobes and Horn Strobes for Wall Applications General The L-Series audible visible notification products
More informationXUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m
Characteristics photo-electric sensor - XUB - thru beam - laser - Sn 100m - 12..24VDC - cable 2m Buy online Complementary Enclosure material Lens material Blind zone Output type Status LED [Us] rated supply
More informationpanasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers
687 Optical Touch Switch SW-1 SERIES Related Information General terms and conditions... F-3 General precautions... P.1595 PHOTO PHOTO Conforming to OSHA / ANSI Listing MEASURE panasonic.net/id/pidsx/global
More information