PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

Size: px
Start display at page:

Download "PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20"

Transcription

1 PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible. Easy; significantly shorter assembly and installation times. Economical; extremely high efficiency and good penetration of acoustical obstacles significantly reduce the required number of sounders. IP 66 IK C 40 C EN 54-3 VdS UL 10 Years Schutzart impact-proof housing operating temperature acoustic penetration external tone selection V DC V DC warranty PRODUCT PA 10 PA 20 DATA Operating range V V V V V V AC Hz DC AC Hz DC Nominal current consumption ma ma ma ma ma ma Sound pressure level 110 db(a) 120 db(a) Sound level reduction max. 12 db via potentiometer Alarm tones 80 / 4 tones are externally selectable Duty cycle 100 % Operating temperature 40 C C Storage temperature 40 C C Relative humidity 90 % Protection system according to EN 6052 IP 66 Protection class II Material PC / ABS blend similar to RAL 3000 (flame red) RAL 7035 (light grey) RAL 9003 (signal white) Cable entry 5x M20 knock-outs on side, 1 knock-out on back Integrated seal with cable entry 6 13 mm (feed-through grommet) Connecting terminals 2.5 mm 2 fine wire with cable end sleeve, AWG 16 Weight 1,060 g 1,050 g 1,200 g 1,090 g 1 Power consumption dependent on operating voltage. OPTIONS/ACCESSORIES I lim t Enclosure fitting Surface gasket Tamperproof sealing Panel mounting kit

2 DIMENSIONS PA 10 PA Ø Ø 9 M20 prepared M20 prepared AUDIBLE SIGNALING DEVICES ARTICLE PA 10 PA 20 VERSION RATED VOLTAGE V AC 24 V AC V DC V AC 24 V AC V DC Standard housing red GL/MED housing red Standard housing grey GL/MED housing grey Article numbers for other voltages and versions on request. ARTICLE PA 10 PA 20 Enclosure fitting For connection (daisy-chaining) of several sounders of the PATROL series Surface gasket Tamper-proof sealing (pack of 4) Panel mount installation kit PATROL Sealing of the sounder installation surface when, e. g. cable entry is executed from the back. Anti-tamper sealing for fasteners of the PATROL devices after installation in order to prevent manipulation of the devices. The PATROL devices are also suitable for panel mounting. This kit consists of a plug connector for the electrical contact, as well as all installation materials

3 PRODUCTS AUDIBLE SIGNALING DEVICES TONE TABLE 15 evacuation alarm Netherlands NEN evacuation alarm Australia AS NFPA 775 Hz Pulsating tone, Australien alert AS1670, ISO , (fast), IMO 3d, Germany KTA3901 evacuation alarm Hz 65, Sweden SS (all-clear signal) 66 67, Germany KTA3901 (all-clear signal) Hz PFEER (general alarm), UK BS (back-up alarm) PFEER (general alarm) Hz 10 s 40 s 10 s Hz Hz 54, Finland (all-clear signal) 1 55, PFEER gas alarm Sweden SS (local warning) 103 Sweden SS (air raid warning) Sweden SS (emergency signal) 107 Germany KTA3901 (evacuation alarm) 420 Hz 109 Australia AS2220, AS1610, AS (fast variable), bell 111 ISO8201 (emergency evacuation signal), USA (evacuation alarm) 470 Hz 112 ISO8201 (emergency evacuation signal) 113 ISO8201 (emergency evacuation signal), sweeping 7s 7s 4 ms 0,7 s Sweden SS (important message (pre-mess)) 4 ms Hz 680 Hz Sweden SS (emergency signal) (fast), Horn Hz Hz Hz 1 P FA N N E N B E R G. C O M 61, general alarm Finland 46 0,85 s 422 Hz 3,75 s (medium), UK BS ,5 s 1600 Hz (fast), UK BS ,6 s, France NFC (fast) 0,3 s 60 0,3 s 0,875 s 0,875 s 13 s 6,5 s 1,8 s 1,8 s 150 ms 150 ms 900 Hz Hz 0,75 s 0,625 s 0,625 s 1450 Hz 0,69 ms 2850 Hz 970 Hz 59 (fast), UK BS Hz 57 fire alarm, UK BS Sawtooth, DIN tone Germany (emergency signal), PFEER PTAP no tone 2 1

4 0, TONE TABLE IMO (telephone call) IMO (leave ship) IMO SOLAS III/50 + SOLAS III/6.4 (general alarm) 122 Alternating tone 123 Alternating tone 124 Singapore 125 Alternating tone 128 Alternating tone 130 UK BS (fire alarm) CONTROL OF THE TONES s s 0.25 s 2000 Hz 0.5 s 3 s 0.5 s 2,5 s 7 s 1025 Hz 2,5 s 0.25 s 0.25 s 2400 Hz 0.5 s 0.25 s EN s 0.25 s s s 1025 Hz DIP-SWITCH EXTERNAL TONE SELECTION (SETTING OF BASIC TONE) C1 C2 C1+C BASIC TONE TONE ON 2 * ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON * factory setting UK BS (fire alarm, railway crossing) UK BS (fire alarm, increased urgency railway crossing) 142 Alternating tone Alternating tone France NFS (fire alarm) Sweden SS Sweden SS Alternating tone (two tone chime) 900 Hz 650 Hz 0,4 s 650 Hz 2 s DIP-SWITCH EXTERNAL TONE SELECTION (SETTING OF BASIC TONE) C1 C2 C1+C BASIC TONE TONE ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON AUDIBLE SIGNALING DEVICES

5 PRODUCTS AUDIBLE SIGNALING DEVICES CONNECTION DIAGRAM X2 -L -L +N +N C1 C2 C1 C2 electrical connection and tone selection through external control of C1 and C2 operating voltage connection N - L + AC: DC: DC + - S2 S2 (by-passing the reverse polarity protection diode) with reverse polarity protection (factory setting) without reverse polarity protection + - AC S3 S1 volume control Note: In order to conform to EN54-3, the volume control must be set to the maximum position S3 tone selection switch S1 (selection of the polarity of the control voltage for C1 and C2) factory setting + CONFORMITY TO STANDARDS The acoustic parameters conform to the European standard DIN EN ISO 7731: Ergonomic alarms for public areas and workplaces acoustic alarms. The requirement for an acoustic alarm signal can be found in the harmonised standards: EN Electrical equipment of machines EN Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 08

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.

More information

Multi Tone Alarm Sounders A

Multi Tone Alarm Sounders A Multi Tone Alarm Sounders A S I G N A L G E R Ä T E Size 2 Size 3 Size 4 ASS-P ASS-T ASM ASL ASX 103 db 108 db 113 db 120 db 127 db 8 tones 32 tones 32 tones 63 tones 63 tones Features w Comprehensive

More information

Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon

Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon Technical Specification 1. Sounder Supply Voltage Range 10-60V DC Current 0.12 0.55A* (Typ. 0.5A @ 24V,

More information

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10 PRODUCT INFORMATION PI 38.43 Sounder SG 200 Page 1 of 10 Table of Contents 1. Product Description............................... 3 2. Features......................................... 3 3. Functional Description............................

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

Explosion Proof Combination Signal db (A) / 5 Joule

Explosion Proof Combination Signal db (A) / 5 Joule Explosion Proof Combination Signal - Operating instructions Additional languages www.r-stahl.com General information Contents 1 General information...2 1.1 Manufacturer...2 1.2 Information regarding the

More information

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas UL 1203 CSA C22.2 NO. 30-M1986 The D1xS1 and D1xS2 Alarm Horns also comply with the following standards for signaling

More information

X10 Mini, Midi & Maxi

X10 Mini, Midi & Maxi Industrial Sounder, Sounder Beacon X0 Mini, Midi & Maxi Installation Manual EAT X0 Mini, Midi & Maxi Installation Manual (90F) Contents Overview and purpose... Product assembly... Select wiring method......

More information

AP200 SERIES INTELLIGENT ALARM DEVICES

AP200 SERIES INTELLIGENT ALARM DEVICES Tech Data Sheet D017GB1 Fire Detection /01 AP00 SERIES INTELLIGENT ALARM DEVICES Intelligent AP00 series alarm devices for FX NET fire detection system The intelligent AP00 series alarm devices are used

More information

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control. E2S Datasheet 1.2.1 v10a ISmA1 ISminialarm The ISmA1 is a compact, 100dB(A) alarm sounder. Approvals include ATEX, IECEx and GOSTR for Zone 0 applications and FM approval for Class I Division 1 and Class

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D1xC COMBINED RADIAL HORNS & STROBES For Use In Hazardous Locations - Gas 3) Ratings and Markings The D1xC1 and D1xC2 combined alarm horns and strobes comply with the following

More information

AP200 SERIES INTELLIGENT ALARM DEVICES

AP200 SERIES INTELLIGENT ALARM DEVICES Tech Data Sheet D0170GB Fire Detection /01 AP00 SERIES INTELLIGENT ALARM DEVICES Intelligent AP00 series alarm devices for FX fire detection system The intelligent AP00 series alarm devices are used in

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT

More information

Product Manual Standard Asserta Sounder Range

Product Manual Standard Asserta Sounder Range Product Manual Standard Asserta Sounder Range Document Structure: Steve Martin - 18/09/08 Technical Information: Chris Anderson - 14/10/08 Cooper Fulleon Ltd Llantarnam Park Cwmbran South Wales NP44 3AW

More information

E2S Datasheet v10a

E2S Datasheet v10a E2S Datasheet 1.2.3 v10a ISmC1 ISminialert The ISmC1 is a compact combined 100dB(A) alarm sounder and L.E.D. beacon only one Zener barrier or galvanic isolator required to run both sounder & beacon or

More information

INSTRUCTION MANUAL (ATEX)

INSTRUCTION MANUAL (ATEX) INSTRUCTION MANUAL (ATEX) ISmA1M Minialarm Intrinsically Safe Round ISmA1M Volume Control Tone Generator S3 Tone Selection Switches Fig 1 Simplified block diagram The ISmA1M sounder is CE marked for compliance

More information

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder 1) Introduction The Appello tone and speech annunciation sounder has three different styles in AC and DC. A105NAPPX

More information

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V. Signaling Devices Acoustic Signaling Devices 28 Optical Signaling Devices 30 26 Signaling Devices Acoustic Signaling Devices Acoustic Signaling Devices MSS300-SA SG 200 DS 10 LSN/GLT GLT GLT GLT Operating

More information

Xenex Conventional Fire Detection & Alarm System

Xenex Conventional Fire Detection & Alarm System SECTI 4: page 1 Section 4: Xenex Conventional Fire Detection & Alarm System SECTI 4: page 3 Xenex system architecture Beam Transmitter Beam Receiver End of Line Call Point Smoke Detector Smoke Detector

More information

4) Intrinsic Safety Certification

4) Intrinsic Safety Certification INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for

More information

Bulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices

Bulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices Bulb Overview PART NO. DESCRIPTION TOTAL LENGTH(mm) VOLTAGE FOR USE WITH: 955 840 34 Bulb BA15d 5 W 42 12 V 200 203 209 641 800 840 845 955 840 35 Bulb BA15d 5 W 42 24 V 200 203 209 641 800 840 845 955

More information

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder AUTHORIZED DISTRIBUTOR ControlSystemsUSA.com Houston, Texas USA sales@controlsystemsusa.com 832-615-3588 INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

More information

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm VIMPEX Sounder Range Fire Alarms Banshee Electronic Sounders FlashDome EN 54-3 Evacuation Audible Alarm BS 5839-1 Beacons The range of sounders, beacons, sounder beacons and accessories represents the

More information

Conventional Fire Detection

Conventional Fire Detection SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct

More information

Optical-Audible Signal Devices

Optical-Audible Signal Devices Overview LED/Buzzer Combination LED/Multi-Tone er Combination 150 Installation model 450 Installation model with acknowledgement funcition 450 Installation model for AS- Interface 420 Base mounting 422

More information

OPERATING AND INSTALLATION

OPERATING AND INSTALLATION A division of Signature Ind. Ltd YO6 YL6 V6 DIMENSIONS (mm) 280mm 11 OPERATING AND INSTALLATION INSTRUCTIONS FOR (UL & ATEX) YODALEX FLAMEPROOF AUDIBLE AND VISUAL ALARMS D7292 OPERATING CLASS 1 DIVISION

More information

Segnalatori acustici AW-ETH12MD AW-ETH12MD audible warning

Segnalatori acustici AW-ETH12MD AW-ETH12MD audible warning Segnalatori acustici audible warning devices I segnalatori acustici, sono utilizzati in ambienti a basso rumore di fondo, ove sia presente una potenziale atmosfera esplosiva. Sono dotati di circuito a

More information

VTG-32E Spatial Sounder 24Vdc EN54 part 3 approved

VTG-32E Spatial Sounder 24Vdc EN54 part 3 approved The VTG32E family of sounders have been designed to cover a wide spectrum of applications. The 24 volt EN543 approved version is for use with conventional fire alarm systems including SAVWIRE two wire

More information

ATEX. IECEx. culs GOST-R. VdS

ATEX. IECEx. culs GOST-R. VdS 1. Hazardous Area Signalling 1.11 Intrinsic safety: Visual 1.12 Intrinsic safety: Audible 1.13 Intrinsic safety: Combination 1.14 Intrinsic safety: Manual Call Points 1.21 Explosion / flame proof: Visual

More information

Sonos-SB Siren/Beacon

Sonos-SB Siren/Beacon Sonos-SB Siren/Beacon Audible/optical signal transmitter compliant with EN 54-3 and EN 54-23 for fire alarm systems, in red and white. Wall mounting (category W) and ceiling mounting (category C) for indoor

More information

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S www.stahl.de > Corrosion resistant omnidirectional high output sounder > Integrated Ex d enclosure > Extreme temperature range > 3 stage alarm with independant tone selection for V DC systems > IP66 IP67

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExTS110D Flameproof Sontel 1) Introduction The BExTS110D is a flameproof Sontel telephone sounder which is certified to the meet the requirements of the ATEX directive

More information

Installation Instructions for W2H Series Signals

Installation Instructions for W2H Series Signals Installation Instructions for W2H Series Signals IF1513 A Description and Operation DIMENSIONS W2H A 8 7/8" (225 mm) B 8 1/4" (210 mm) C 13" (330 mm) Figure 1. Speaker/Amplifier Dimensions The W2H signaling

More information

Segnalatori acustici AW-ETH20MD Audible warning devices

Segnalatori acustici AW-ETH20MD Audible warning devices Segnalatori acustici Audible warning devices I segnalatori acustici sono utilizzati in ambienti aperti ad alto rumore di fondo, ove sia presente una potenziale atmosfera esplosiva. Sono dotati di circuito

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

YO3 - YO4 / YL4 - YO5 / YL5

YO3 - YO4 / YL4 - YO5 / YL5 C l i f f o r d & S n e l l YO3IS YO4IS DIMENSIONS mm 81(3.2 ) 90(3.5 ) YO3 - YO4 / YL4 - YO5 / YL5 Intrinsically Safe Audible and Visual Alarms ATEX YO5IS YL4IS YL5IS 90(3.5 ) 81(3.2 ) MAIN FEATURES BASEEFA

More information

XP95 Sounder VAD Base

XP95 Sounder VAD Base PP2478/2016/Issue 5 XP95 Sounder VAD Base FUNC TION The XP95 Sounder Visual Alarm Device (VAD) Bases incorporates a standard mouting base with a loop-powered sounder VAD. It is used to signal a fire alarm

More information

Flex-Tone Explosionproof Electronic Signals ETH655 & ETH855 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Installation

Flex-Tone Explosionproof Electronic Signals ETH655 & ETH855 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Installation Flex-Tone Explosionproof Electronic Signals ETH655 & ETH855 Installation & Maintenance Information IF 1494 SAVE THESE INSTRUCTIS FOR FUTURE REFERENCE Description and Operation Cooper Crouse-Hinds Hazardous

More information

LC1 Modular Ceiling Loudspeaker Range. en Installation note

LC1 Modular Ceiling Loudspeaker Range. en Installation note LC1 Modular Ceiling Loudspeaker en Installation note LC1 Modular Ceiling Loudspeaker Table of Contents en 3 Table of contents 1 System Overview 4 1.1 Housings 4 1.2 Loudspeakers 5 1.3 Accessories 6 2

More information

Interface and EOL Modules 8

Interface and EOL Modules 8 Interface and EOL Modules Interface Modules Series 420 25 Interface Modules Series 100 291 EOL Modules 293 254 Interface and EOL Modules Interface Modules Series 420 Interface Modules Serie 420 Interface

More information

Auer - Signal tower ECO Ø70 mm modular

Auer - Signal tower ECO Ø70 mm modular products Panel Signalling Signal Towers - Auer Auer - Signal tower ECO Ø70 mm modular Modular system with bayonet fitting for quick assembly LED or conventional filament lamp for cost sensitive applications

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

AUDIBLE SIGNALIZATION

AUDIBLE SIGNALIZATION 01 SIGNALIZATION AUDIBLE SIGNALIZATION PROGRAMMABLE ELECTRONIC MULTITONE SIRENS WITH TWO INPUTS Specially designed for marine application With two inputs where using each one, different tones and frequency

More information

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21 Electronic Standard Devices Annunciator Relay MR and MRE MR 2 and MRE 2 The products described in this brochure are intended for industrial use and meet the requirements laid down by the EU directive 7

More information

SELECT-A-HORN/STROBE SERIES

SELECT-A-HORN/STROBE SERIES SELECT-A-HORN/STROBE SERIES Features Description Mircom s Select-A-Strobe/Horn Series is designed to comply with the Americans with Disability Act (ADA) and meet UL standard 1971 requirements for emergency

More information

DB5 Intrinsically Safe Sounder Type DB-5

DB5 Intrinsically Safe Sounder Type DB-5 Operating Instructions RTK Instruments Limited DB5 Intrinsically Safe Sounder Type DB-5 Description The DB5 Sounder is a strong, lightweight warning sounder, CENELEC certified to Ex II 1G EExia IIC T4

More information

LB3-PCx50 Premium Cabinet Loudspeakers

LB3-PCx50 Premium Cabinet Loudspeakers Communications Systems LB3-PCx Premium Cabinet s LB3-PCx Premium Cabinet s High quality music and speech reproduction Weatherized, suited for sheltered outside use Prepared for Bosch WLS, EOL and DMY pcb

More information

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL PRODUCT NAME: SD-100-1- WEATHER-PROOF SOUNDER/HORN DOC NO.: EX-TECH SIGNALLING SAS-12-SD100-1-TM REV03 WEATHERPROOF SOUNDER/HORN IP66 SD-100 SERIES EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN

More information

Intellia Sounder Bases and Sounder Beacon Bases

Intellia Sounder Bases and Sounder Beacon Bases Intellia Bases and Beacon Bases The Base and Beacon Base are a local-area alarm devices designed for indoor use. They can be connected only to detection systems using Intellia detectors and FX control

More information

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon Sounders Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon Pg 185 186 187 188 189 190 191 Y03 1YA030207 1YA030203 1YA030205 YL030/24 A1:2002 YL030110/230 UL464 C22.2 No. M1983 BS

More information

Technical Manual for the Horn DB1P UL DB1HP UL

Technical Manual for the Horn DB1P UL DB1HP UL Technical Manual for the Horn DB1P UL DB1HP UL Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibility for damage, loss or expense

More information

The Use of Public Address System to Improve Tunnel Safety - Current Practices. Lim Hock Tay

The Use of Public Address System to Improve Tunnel Safety - Current Practices. Lim Hock Tay The Use of Public Address System to Improve Tunnel Safety - Current Practices Lim Hock Tay Content 1 Introduction 2 3 Overview of Survey Responses Discussion 4 Conclusion PIARC International Conference

More information

Part Number Structure ZA 016 L D CT

Part Number Structure ZA 016 L D CT Product Application Guide- 22mm Industrial Alarms with Terminal Block Part Number Structure ZA 016 L D CT Series: ZA = 22mm Maximum Voltage: 016 = 6-16; 028 = 16-28; 048 = 28-48; 120 = 48-120 Sound Level:

More information

Audible warning devices for external alarm

Audible warning devices for external alarm VdS SCHADENVERHÜTUNG VdS Publisher: Gesamtverband der Deutschen Versicherungswirtschaft e.v. (GDV) Büro Schadenverhütung Publishing house: VdS Schadenverhütung Rules for Intruder Alarm Systems Audible

More information

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21 Power Station Control Systems Power Distribution Control Systems Control Room Technology Automation Equipment The products described in this brochure

More information

SOUNDER BASES AND SOUNDER BEACON BASES

SOUNDER BASES AND SOUNDER BEACON BASES Tech Data Sheet D01513GB3 44/2011 Fire Detection SOUNDR BASS AND SOUNDR BACON BASS Intellia Sounder Bases and Sounder Beacon Bases The Sounder Base and Sounder Beacon Base are a local-area alarm devices

More information

PolyGard 2-channel Gas Controller MGC-03

PolyGard 2-channel Gas Controller MGC-03 PolyGard 2-channel Gas Controller MGC-03 DESCRIPTION Gas measuring and monitoring controller based on state-ofthe-art micro-technology with integrated buzzer for continuous monitoring of the ambient air

More information

Conventional Audible Visual Range

Conventional Audible Visual Range Conventional Audible Visual Range Visual Devices Non-Addressable Audible Visual Devices Base Sounder Honeywell s conventional audible visual devices operate over a wide input voltage range of 9 to 33VDC

More information

DB1 Range - HORNS - Up to 103 db(a)

DB1 Range - HORNS - Up to 103 db(a) DB1 Range - HORNS - Up to 103 db(a) Explosion-proof, Weatherproof Features UL listed Class I, Div. 1, Groups C & D. Class 1, Zone 1. ATEX approved. NEMA 4x, IP66. Certified temperature: 13 F to +158 F.

More information

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional

More information

Half-Dome. the Design-Tower. Compact

Half-Dome. the Design-Tower. Compact the Design-Tower 81 Compact 82 compact signal towers Visual-audible LED signal tower system in semicircular design Modern signal tower design Available to order pre-configured or with customised tower

More information

DICTATOR Hold-Open Systems for Hazardous Areas

DICTATOR Hold-Open Systems for Hazardous Areas DICTATOR for Hazardous Areas Products to be used in hazardous areas obviously have to meet special demands. The European ATEX directives (first the EN 94/9/EG and then the directive 2014/34/ EU) brought

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

DEB71. Earth Leakage Monitoring Relay. Benefits. Description Earth Leakage Monitoring Relay Benefits Adjustable trip level. Adjustable leakage threshold from 30mA to 5A or from 300mA to 30A. 2 outputs. Two relay outputs provide, besides the alarm signal an additional

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information

Installation and user manual for the BiWire / Conventional Repeater Panel

Installation and user manual for the BiWire / Conventional Repeater Panel Panel EFBWCV-REPEATER Contents Introduction.... 3 Purpose... 3 The Panel.... 3 Indication Equipment (IE).... 3 Power Supply Equipment (PSE).... 4 System Wiring.... 5 Status Indications.... 5 Repeater I/O....

More information

Technical Manual for the Horn - DB1PUL DB1HP UL

Technical Manual for the Horn - DB1PUL DB1HP UL Technical Manual for the Horn - DB1PUL DB1HP UL Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibility for damage, loss or

More information

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions TrueAlert NonAddressable, MultiCandela Notification Appliances Installation Instructions PRODUCT IDENTIFICATION REFERENCE (See Page 4 for Detailed Product Specifications) Type Mount Model Color Operation

More information

Addressable Detectors & Bases

Addressable Detectors & Bases Edwards Signaling Catalog u Intelligent Initiating Addressable Detectors & Bases Detectors: E-PD, E-PHD, E-HD Bases: B4U, RB4U, IB4U, SB4U Overview Edwards intelligent addressable detectors are meticulously

More information

Universal fault annunciator for panel mounting

Universal fault annunciator for panel mounting Universal fault annunciator for panel mounting Communication over Ethernet USM - Universal-fault annunciator for panel mounting Low depth housing for panel mounting Versions with 8, 16, 32 or 48 inputs

More information

The EN54 Part 2 and 4 Fire System

The EN54 Part 2 and 4 Fire System Scope of work: To design, supply, install and commission a Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54 Part 2 and 4 Fire

More information

Smoke and Fire Curtains

Smoke and Fire Curtains Smoke and Fire Curtains NFPA UL Datasheet firecurtaintech.com SMOKE AND FIRE CURTAINS Fire Curtain Technologies distributes a wide range of fire and smoke protective curtains to protect every type of building

More information

Part Number Structure ZT 028 L D CT R 15

Part Number Structure ZT 028 L D CT R 15 Product Application Guide- 22mm Industrial Alarms with LED Lights Part Number Structure ZT 028 L D CT R 15 Series: ZT = 22mm with LED Maximum Voltage: 016 = 9-16; 028 = 20-28; 120 = 48-120 Sound Level:

More information

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side s Frost detectors for use on the air side QAF63.2-J QAF63.6-J Active capillary tube sensor for acquiring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10

More information

L-Series, Indoor Strobes and Horn Strobes

L-Series, Indoor Strobes and Horn Strobes Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Strobes/Horn Strobes for Ceiling Applications General The L-Series audible visible notification products offer

More information

SERIES 65 ENGINEERING PRODUCT GUIDE

SERIES 65 ENGINEERING PRODUCT GUIDE SERIES 65 ENGINEERING PRODUCT GUIDE Wide Voltage Conventional Detectors Series 65 incorporates well-proven sensing technologies, including an Integrated Circuit based on that used in XP95 analogue addressable

More information

Photoelectric sensors W27-3, Photoelectric proximity sensor, Background suppression

Photoelectric sensors W27-3, Photoelectric proximity sensor, Background suppression ONLINE DATA SHEET www.mysick.com Photoelectric sensors W27-3, Photoelectric proximity sensor, Background suppression WTB27-3K2411 Photoelectric sensors W27-3, Photoelectric proximity sensor, Background

More information

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12 Characteristics photo-electric sensor - XUX - multi - Sn 0..40m - 12..24VDC - M12 Complementary Enclosure material Lens material Maximum sensing distance Output type Add on output Status LED [Us] rated

More information

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual From urgent alarms to routine messages, the PD141AFO VIGILANTE handles all types of operational messages with simplicity and economy. The VIGILANTE

More information

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature 1 858 1858P01 1858P02 1859P02 Symaro Room Sensors for relative humidity (high accuracy) and temperature AQF3150 QFA31 Use Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 4 20 ma for r h and

More information

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics by Tomar Electronics SIRENS POWER ALARM PROGRAMMABLE MULTI-SOUND INDUSTRIAL SIGNALS The POWER ALARM siren is a heavy duty industrial audible alarm designed to operate under adverse industrial conditions

More information

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products 1 821 1821P01 Frost sensors for use on the air side Active capillary tube sensor for measuring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10 V Use On

More information

LF-4000 Series Conventional Fire Alarm Control Unit

LF-4000 Series Conventional Fire Alarm Control Unit LF-4000 Series Conventional Fire Alarm Control Unit Features: 1 to 36 Zone Control Panels Control Key Switch Easy Push Button Control Switches Zone Circuit Monitoring for Open and Short Sounder Circuit

More information

ELECTRONIC PARTS - CATALOGUE

ELECTRONIC PARTS - CATALOGUE Smoke and Heat Ventilation Pneumatic - Electronic Control Systems K + G Pneumatik GmbH In der Krause 48 52249 Eschweiler Germany. +49 (0) 24 03 / 99 50-0 ; +49 (0) 24 03 / 655 30 Grasl Pneumatic-Mechanik

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Quick Selection Guide Fire Systems LSN Periphery

Quick Selection Guide Fire Systems LSN Periphery Local SecurityNetwork Easy wiring Auto configuration capability (self-learning mode) Central programming of all device configurations from the panel Flexible network structure (Loop, stub, T-tap & mixed

More information

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual PD154 & PD158 VIGILANTE II ANNUNCIATORS 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal Power

More information

INSTRUCTION MANUAL A131 High Level Audible Warning System

INSTRUCTION MANUAL A131 High Level Audible Warning System Weight: 1.5kg single AC unit 2.9kg four way AC unit Marking: 3) Installation Requirements 1) Introduction The A131 high level audible warning system is an effective wide area warning alarm system and can

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm

More information

DSE ELECTRONIC SIRENS Advantages & Functions

DSE ELECTRONIC SIRENS Advantages & Functions DSE ELECTRONIC SIRENS Advantages & Functions DSE ELECTRONIC SIRENS These modern, high-powered warning sirens are used to warn people of ecological, military, terrorist, catastrophic and other hazards.

More information

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Phone: 040 807-0 Fax: 040 807-259 Alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC display

More information

WIDE RANGE SPEAKER INSTRUCTION MANUAL TABLE OF CONTENTS

WIDE RANGE SPEAKER INSTRUCTION MANUAL TABLE OF CONTENTS INSTRUCTION MANUAL WIDE RANGE SPEAKER CS-64BS TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION AND FEATURES... 3 3. IMPEDANCE CHANGE... 3 4. WIRING 4.1. When No Bridge Connection is

More information

More Precision. indusensor // Linear inductive displacement sensors

More Precision. indusensor // Linear inductive displacement sensors More Precision indusensor // Linear inductive displacement sensors 4 Gauges with external controller indusensor LVDT - Proven LVDT technology - Measuring ranges ±1 ±10mm - Excellent price/performance ratio,

More information

Industrial Signalling

Industrial Signalling Industrial Signalling Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place. Product Range

More information

INSTRUCTION MANUAL TABLE OF CONTENTS

INSTRUCTION MANUAL TABLE OF CONTENTS INSTRUCTION MANUAL WIDE RANGE SPEAKER CS-154BS TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION AND FEATURES... 3 3. IMPEDANCE CHANGE... 4 4. WIRING 4.1. When No Bridge Connection is

More information

Remote alarm indicator and test combination MK2430

Remote alarm indicator and test combination MK2430 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Tel.: 040 807-0 Fax: 040 807-259 Remote alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC

More information

BL 200 Strobes. Page F.01U A1.en/ 6/2/2004 ST / PMF1 / zab

BL 200 Strobes. Page F.01U A1.en/ 6/2/2004 ST / PMF1 / zab PRODUCT INFORMATION BL 200 Strobes Page 1 601- F.01U.000.862 A1.en/ 6/2/2004 ST / PMF1 / zab Table of Contents 1. Product Description............................... 2 2. Features.........................................

More information

L-Series, Indoor Strobes and Horn Strobes

L-Series, Indoor Strobes and Horn Strobes Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Horns, Strobes and Horn Strobes for Wall Applications General The L-Series audible visible notification products

More information

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m Characteristics photo-electric sensor - XUB - thru beam - laser - Sn 100m - 12..24VDC - cable 2m Buy online Complementary Enclosure material Lens material Blind zone Output type Status LED [Us] rated supply

More information

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers 687 Optical Touch Switch SW-1 SERIES Related Information General terms and conditions... F-3 General precautions... P.1595 PHOTO PHOTO Conforming to OSHA / ANSI Listing MEASURE panasonic.net/id/pidsx/global

More information