AP200 SERIES INTELLIGENT ALARM DEVICES

Size: px
Start display at page:

Download "AP200 SERIES INTELLIGENT ALARM DEVICES"

Transcription

1 Tech Data Sheet D017GB1 Fire Detection /01 AP00 SERIES INTELLIGENT ALARM DEVICES Intelligent AP00 series alarm devices for FX NET fire detection system The intelligent AP00 series alarm devices are used in the FX NET fire detection system. They have been designed to reduce significantly the total cost of installation. Product performance has been optimized to allow the maximum permissible number of devices to be installed on an intelligent loop. Wall mount devices WST-PC-I WST-PC-N The sounders and visual alarm devices are installed in exactly the same manner as an intelligent fire detector. The devices use the B01AP detector base. At final commissioning, the sounder or strobe simply twists into the base and the installation is complete. This simple but effective concept significantly reduces the time and cost of installing audible visual warning devices when compared with previous designs. In addition, fire systems designers benefit from the flexibility of being able to change the type of installed device if the protected building is reconfigured by the occupiers. WSS-PC-I WSS-PC-N Fault finding is also easy. The suspect device is removed with a simple twist action without having to disconnect any loop wiring; a replacement is then mounted into the base. The visual alarm devices VADs are EN- approved as open class devices and sounders are EN- approved.

2 Tech Data Sheet D017GB1 Fire Detection /01 Mechanical dimensions Electrical installation, Base B01AP Wall mount devices 11 1 (+) (+) (-)1 SHIELD FX SLC addressable loop WST-PC-xxx Deep Base BPW-E010 and Waterproof Base WPW-E WSS-PC-xxx Schneider Electric Fire & Security Oy Sokerilinnantie 11 C, 000 Espoo, Finland Telephone: Fax: Document Number D017GB1 01

3 Tech Data Sheet D017GB1 Fire Detection /01 Mechanical installation Bases/IP rating Mounting Affix B01 AP base to suitably flat wall or ceiling. Terminate the cable to the appropriate terminals. For surface mount wiring the cable can enter the B01 AP base via the break outs provided. Select the appropriate tone and volume settings via the DIP switch. Locate the main assembly on to the base by rotating until it locks into place. Wall mount: B01AP Base (IP1C) Deep Base BPW-E010 (IP) Waterproof Base WPW-E010 (IP) If the waterproof option is required then the wall gasket must be fitted behind the deep base, and the sealing o-ring fitted after attaching the low profile base. Schneider Electric Fire & Security Oy Sokerilinnantie 11 C, 000 Espoo, Finland Telephone: Fax: Document Number D017GB1 01

4 Tech Data Sheet D017GB1 Fire Detection /01 Anti tamper lock The B01 AP base also includes a tamper resistant feature that when activated prevents removal of the unit without the use of a special tool. This method is consistent with the a tamper feature across all devices using this base. This prevents the device being turned to enable its release. Wall mount: Examples: Address setting x x1 Address setting x x1 Note! Address setting 01 is used with the FX- LC loop controller. Volume and tone setting (WST-, WSS-) Volume setting is selected by SW and SW7 of the 8 way DIP switch (see table Volume settings). The appropriate tone set is selected by SW1 to of the 8 way DIP switch (see table Tone settings). The nd stage tone (related to the 1 st stage tone) is controlled by the fire panel via the protocol. Address setting The address setting in the devices is simply done with two rotary decimal switches, thus having a range of 1 1. In addition the panel can distinguish between detector addresses, I/O-module addresses and sounder addresses, and thus providing a total address capacity per loop of and 01, altogether 18 addresses. Two rotary switches are located either side of the dip switch unit. 7 Volume settings x10 SW SW7 Volume setting OFF OFF High OFF ON Medium ON OFF Low ON ON Low OFF = 0, ON = 1 1 ON ON Schneider Electric Fire & Security Oy Sokerilinnantie 11 C, 000 Espoo, Finland Telephone: Fax: Document Number D017GB1 01

5 Tech Data Sheet D017GB1 Fire Detection /01 Tone settings DIP setting O=Off/1=On SW 1,,,, No Pattern Nominal Frequency Switching Frequency Description Standard 0,0,0,0,0 1 Alternating /0 Hz French Fire Sound (100ms/00ms) AFNOR NFS ,0,0,0,0 Alternating 800/70 1Hz BS8 Pt1 8 0,1,0,0,0 Alternating 800/70 Hz Alternating tone BS8 Pt1 telecoms FP ,1,0,0,0 Alternating 00/00 Hz Alternating High Frquency 10 0,0,1,0,0 Alternating 00/100 Hz Security Alarm 10 1,0,1,0,0 Alternating 88/ Hz 8 0,1,1,0,0 7 Continuous 0 All Clear 1 1,1,1,0,0 8 Continuous 70 BS8 Pt1 0,0,0,1,0 Continuous 100 1,0,0,1,0 10 Continuous 80 HF Continuous 0,1,0,1,0 11 Sweep Raising from 10Hz to 1000Hz in 10 seconds, then 0 seconds at 1000Hz, then falling from 1000Hz to 10Hz in 10 seconds, then 0 seconds at 10 Hz, then repeating. Total period 80 seconds. Gasalarm Tone 1,1,0,1,0 1 Intermittent 0 0.s on,0.s off AS0 alert tone AS0 1 0,0,1,1,0 1 Sweep s off,.7s off AS0 evacuate tone AS0 1 1,0,1,1,0 1 Intermittent 0.Hz 10ms on, 10ms off Swedish Alarm Tone 7 0,1,1,1,0 1 Intermittent Hz 0.s on, 1s off Intermittent Tone BS8 Pt1 8 1,1,1,1,0 1 Intermittent 70 0.Hz 1s on, Backup alarm LF & 1s off BS8 Pt1 BS8 Pt1 8 0,0,0,0,1 17 Intermittent 80 1Hz Backup alarm HF & BS8 Pt1 nd Tone BS8 Pt1 10 1,0,0,0,1 18 Intermittent 70 1Hz 00ms on, 00ms off BS8 Pt1 BS8 Pt1 8 0,1,0,0,1 1 Intermittent 0 0.Hz (0.s on, 0.s off)*, 1.s off ISO ,1,0,0,1 0 Continuous 800 Hz 10ms on, 100ms off BS8 Pt1 0,0,1,0,1 1 Sweep (0.s on, 0.s off)*, Temporal ISO801 1.s off Evacuation tone Temporal 1 1,0,1,0,1 Sweep Hz 1s on, Evacuate, DIN tone & 0.01s off PFEER DIN, PFEER 0 0,1,1,0,1 Sweep Hz Fast Sweep Vds Vds 10 1,1,1,0,1 Sweep sec off.sec on Slow whoop evacuate Netherlands NEN 7 8 0,0,0,1,1 Sweep Hz LF buzz BS8 Pt1 BS8 Pt1 8 1,0,0,1,1 Sweep Hz Fast sweep LF BS8 Pt1 BS8 Pt1 8 0,1,0,1,1 7 Sweep Hz Medium sweep LF buzz BS8 Pt1, BS8 Pt1 VdS 8 Vds 1,1,0,1,1 8 Sweep Hz High frequency buzz 10 0,0,1,1,1 Sweep Hz Fast whoop 8 1,0,1,1,1 0 Sweep Hz rise 1 s, 00 stable s, fall 1s Siren style tone 8 0,1,1,1,1 1 Sweep Hz 8 1,1,1,1,1 Sweep Hz 10 nd Stage Tone Schneider Electric Fire & Security Oy Sokerilinnantie 11 C, 000 Espoo, Finland Telephone: Fax: Document Number D017GB1 01

6 Tech Data Sheet D017GB1 Fire Detection /01 Sounder current consumption Typical current consumption DIP setting O=Off/1=On No Wall mount devises SW 1,,,, (WSS) (WSS) (WSS) High Medium Low 0,0,0,0,0 1.0/../.8 1./. 1,0,0,0,0./8.7./. 1./.7 0,1,0,0,0./8..8/.1 1./.7 1,1,0,0,0./8../. 1.7/.0 0,0,1,0,0.7/10.0./. 1.8/.1 1,0,1,0,0./../.8 1./.7 0,1,1,0,0 7.0/8../.8 1./.7 1,1,1,0,0 8.8/8.1./. 1./.7 0,0,0,1,0.8/8.1./. 1./.8 1,0,0,1,0 10./8..7/.0 1./.8 0,1,0,1,0 11./8.8./.8 1./.7 1,1,0,1,0 1./../. 1.1/. 0,0,1,1, /1.7./. 1.7/.0 1,0,1,1,0 1.0/8../.7 1./. 0,1,1,1,0 1.8/8.1./. 1./.7 1,1,1,1,0 1.8/8.1./. 1./.7 0,0,0,0,1 17./8..7/.0 1./.8 1,0,0,0,1 18.8/8.1./. 1./.7 0,1,0,0,1 1./7..1/. 1./. 1,1,0,0,1 0./8../. 1./. 0,0,1,0, /1..1/. 1./. 1,0,1,0,1 10./1../. 1.7/.0 0,1,1,0,1.0/8../. 1./. 1,1,1,0,1 10./1../.8 1.7/.0 0,0,0,1,1.0/7../. 1./. 1,0,0,1,1./7.8./.8 1./.7 0,1,0,1,1 7.1/8..8/.1 1./.7 1,1,0,1,1 8./8../. 1.8/.1 0,0,1,1,1./8.7./.8 1./. 1,0,1,1, /1../.7 1.7/.0 0,1,1,1,1 1./8..7/.0 1./.7 1,1,1,1,1./8../. 1./. Note! For Isolated variants add 0.1mA to high, medium, low values above. Schneider Electric Fire & Security Oy Sokerilinnantie 11 C, 000 Espoo, Finland Telephone: Fax: Document Number D017GB1 01

7 Tech Data Sheet D017GB1 Fire Detection /01 7 Technical data Wall Mount Devices WSS-PC-xxx WST-PC-xx Description Sounder VAD VAD Operating voltage 1 to VDC(isolation) (VDC typical) 1 to VDC (non isolation) (VDC typical) Quiescent current 0µA Max current consumption (sound).0ma (isolation) (High Volume Tone 8@ V) Max current consumption (sound) 8.8mA (non isolation) (High Volume Tone 8@ V) Sound Output to EN- db(a)±db (High Volume Tone 8@ V) EN- coverage See installation instructions Beacon Flash Rate 0, / 1 Hz Max current consumption/strobe (isolation) WST-PC-***.mA Max current consumption/strobe (non isolation) WST-PC-***.1mA Operating Temperature - to 70 C Relative Humidity Up to % (±%) non-condensing IP Rating IPC (with B01 AP base) IP (with Deep base BPW-E10) IP (with Waterproof base WPW-E10) Colour Clear lense Weight g 170g Terminal Size max.mm Number of Tones Volume Setting High, Medium, Low Product codes WSS-PC-I, isolation WSS-PC-N, non isolation WST-PC-I, isolation WST-PC-N, non isolation FFS07117 FFS07117 FFS FFS Bases IP rating Product codes B01AP IP1 FFS BPW-E010 IP FFS07117 WPW-E010 IP FFS07117 Schneider Electric Fire & Security Oy Sokerilinnantie 11 C, 000 Espoo, Finland Telephone: Fax: Document Number D017GB1 01

8 .0 METRES DP 1. METRES DP 1.7 METRES DP 1.7 METRES DP 1.77 METRES DP Tech Data Sheet D017GB1 Fire Detection /01 8 O-Class Coverage Shape WST-PC-x: INSTALLATION_SURFACE 0 0 INSTALLATION_SURFACE INSTALL_HEIGHT INSTALL_HEIGHT 1.8 METRES DP 1. METRES DP 0 FLOOR_LEVEL R0.88 METRES DP FLOOR_LEVEL WSS-PC-x: SCALE 0,00 INSTALLATION_SURFACE 0 0 INSTALLATION_SURFACE INSTALL_HEIGHT INSTALL_HEIGHT 1.80 METRES DP 1. METRES DP 0 FLOOR_LEVEL R0.7 METRES DP FLOOR_LEVEL Schneider Electric Fire & Security Oy Sokerilinnantie 11 C, 000 Espoo, Finland Telephone: Fax: Document Number D017GB1 01

AP200 SERIES INTELLIGENT ALARM DEVICES

AP200 SERIES INTELLIGENT ALARM DEVICES Tech Data Sheet D0170GB Fire Detection /01 AP00 SERIES INTELLIGENT ALARM DEVICES Intelligent AP00 series alarm devices for FX fire detection system The intelligent AP00 series alarm devices are used in

More information

VTG-32E Spatial Sounder 24Vdc EN54 part 3 approved

VTG-32E Spatial Sounder 24Vdc EN54 part 3 approved The VTG32E family of sounders have been designed to cover a wide spectrum of applications. The 24 volt EN543 approved version is for use with conventional fire alarm systems including SAVWIRE two wire

More information

SOUNDER BASES AND SOUNDER BEACON BASES

SOUNDER BASES AND SOUNDER BEACON BASES Tech Data Sheet D01513GB3 44/2011 Fire Detection SOUNDR BASS AND SOUNDR BACON BASS Intellia Sounder Bases and Sounder Beacon Bases The Sounder Base and Sounder Beacon Base are a local-area alarm devices

More information

Opal TM AV Devices. Data Sheet. Benefits

Opal TM AV Devices. Data Sheet. Benefits Opal TM AV Devices Data Sheet Notifier s Opal AV (Audio Visual) range is designed to alert building occupants of an emergency. The Opal AV range of analogue addressable, loop powered, audible and visual

More information

Conventional Fire Detection

Conventional Fire Detection SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct

More information

Xenex Conventional Fire Detection & Alarm System

Xenex Conventional Fire Detection & Alarm System SECTI 4: page 1 Section 4: Xenex Conventional Fire Detection & Alarm System SECTI 4: page 3 Xenex system architecture Beam Transmitter Beam Receiver End of Line Call Point Smoke Detector Smoke Detector

More information

Opal TM AV Devices. Data Sheet. Benefits

Opal TM AV Devices. Data Sheet. Benefits Opal TM AV Devices Data Sheet Notifier s Opal AV (Audio Visual) range is designed to alert building occupants of an emergency. The Opal AV range of analogue addressable, loop powered, audible and visual

More information

Sonos-SB Siren/Beacon

Sonos-SB Siren/Beacon Sonos-SB Siren/Beacon Audible/optical signal transmitter compliant with EN 54-3 and EN 54-23 for fire alarm systems, in red and white. Wall mounting (category W) and ceiling mounting (category C) for indoor

More information

Intellia Sounder Bases and Sounder Beacon Bases

Intellia Sounder Bases and Sounder Beacon Bases Intellia Bases and Beacon Bases The Base and Beacon Base are a local-area alarm devices designed for indoor use. They can be connected only to detection systems using Intellia detectors and FX control

More information

XP95 Sounder VAD Base

XP95 Sounder VAD Base PP2478/2016/Issue 5 XP95 Sounder VAD Base FUNC TION The XP95 Sounder Visual Alarm Device (VAD) Bases incorporates a standard mouting base with a loop-powered sounder VAD. It is used to signal a fire alarm

More information

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.

More information

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.

More information

Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon

Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon Technical Specification 1. Sounder Supply Voltage Range 10-60V DC Current 0.12 0.55A* (Typ. 0.5A @ 24V,

More information

SOUNDER WITH BEACON FOR FIRE DETECTION PANEL

SOUNDER WITH BEACON FOR FIRE DETECTION PANEL ΒS-/ SOUNDER WITH BEAC FOR FIRE DETECTI PANEL OPERATI VOLTAGE MAXIMUM CSUMPTI MAXIMUM SOUND OUTPUT inm BEAC ΤYPE OF APPLICATI ENVIRMENT MOUNTING COVERAGE (y) MOUNTING HEIGHT (x) COVERAGE VOLUME CODE COVERAGE

More information

Multi Tone Alarm Sounders A

Multi Tone Alarm Sounders A Multi Tone Alarm Sounders A S I G N A L G E R Ä T E Size 2 Size 3 Size 4 ASS-P ASS-T ASM ASL ASX 103 db 108 db 113 db 120 db 127 db 8 tones 32 tones 32 tones 63 tones 63 tones Features w Comprehensive

More information

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder 1) Introduction The Appello tone and speech annunciation sounder has three different styles in AC and DC. A105NAPPX

More information

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V. Signaling Devices Acoustic Signaling Devices 28 Optical Signaling Devices 30 26 Signaling Devices Acoustic Signaling Devices Acoustic Signaling Devices MSS300-SA SG 200 DS 10 LSN/GLT GLT GLT GLT Operating

More information

Conventional Audible Visual Range

Conventional Audible Visual Range Conventional Audible Visual Range Visual Devices Non-Addressable Audible Visual Devices Base Sounder Honeywell s conventional audible visual devices operate over a wide input voltage range of 9 to 33VDC

More information

X10 Mini, Midi & Maxi

X10 Mini, Midi & Maxi Industrial Sounder, Sounder Beacon X0 Mini, Midi & Maxi Installation Manual EAT X0 Mini, Midi & Maxi Installation Manual (90F) Contents Overview and purpose... Product assembly... Select wiring method......

More information

CONTROL PANELS. Tech Data Sheet D01688GB1 10/2012 Fire Detection. Control Panels of the FX 3NET (ALC) Fire Detection System

CONTROL PANELS. Tech Data Sheet D01688GB1 10/2012 Fire Detection. Control Panels of the FX 3NET (ALC) Fire Detection System Tech Data Sheet D01688GB1 10/2012 Fire Detection CONTROL PANELS Control Panels of the FX 3NET (ALC) Fire Detection System The FX 3NET intelligent fire detection and alarm system and panels from Schneider

More information

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder AUTHORIZED DISTRIBUTOR ControlSystemsUSA.com Houston, Texas USA sales@controlsystemsusa.com 832-615-3588 INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

More information

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10 PRODUCT INFORMATION PI 38.43 Sounder SG 200 Page 1 of 10 Table of Contents 1. Product Description............................... 3 2. Features......................................... 3 3. Functional Description............................

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

Optical-Audible Signal Devices

Optical-Audible Signal Devices Overview LED/Buzzer Combination LED/Multi-Tone er Combination 150 Installation model 450 Installation model with acknowledgement funcition 450 Installation model for AS- Interface 420 Base mounting 422

More information

Bulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices

Bulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices Bulb Overview PART NO. DESCRIPTION TOTAL LENGTH(mm) VOLTAGE FOR USE WITH: 955 840 34 Bulb BA15d 5 W 42 12 V 200 203 209 641 800 840 845 955 840 35 Bulb BA15d 5 W 42 24 V 200 203 209 641 800 840 845 955

More information

Addressable Detectors & Bases

Addressable Detectors & Bases Edwards Signaling Catalog u Intelligent Initiating Addressable Detectors & Bases Detectors: E-PD, E-PHD, E-HD Bases: B4U, RB4U, IB4U, SB4U Overview Edwards intelligent addressable detectors are meticulously

More information

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics by Tomar Electronics SIRENS POWER ALARM PROGRAMMABLE MULTI-SOUND INDUSTRIAL SIGNALS The POWER ALARM siren is a heavy duty industrial audible alarm designed to operate under adverse industrial conditions

More information

Product Manual Standard Asserta Sounder Range

Product Manual Standard Asserta Sounder Range Product Manual Standard Asserta Sounder Range Document Structure: Steve Martin - 18/09/08 Technical Information: Chris Anderson - 14/10/08 Cooper Fulleon Ltd Llantarnam Park Cwmbran South Wales NP44 3AW

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D1xC COMBINED RADIAL HORNS & STROBES For Use In Hazardous Locations - Gas 3) Ratings and Markings The D1xC1 and D1xC2 combined alarm horns and strobes comply with the following

More information

Consultant Specification AGILE Wireless Fire Detection System

Consultant Specification AGILE Wireless Fire Detection System Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...

More information

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm VIMPEX Sounder Range Fire Alarms Banshee Electronic Sounders FlashDome EN 54-3 Evacuation Audible Alarm BS 5839-1 Beacons The range of sounders, beacons, sounder beacons and accessories represents the

More information

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control. E2S Datasheet 1.2.1 v10a ISmA1 ISminialarm The ISmA1 is a compact, 100dB(A) alarm sounder. Approvals include ATEX, IECEx and GOSTR for Zone 0 applications and FM approval for Class I Division 1 and Class

More information

SAFE AREA AUDIBLE & VISUAL SIGNALLING PRODUCTS

SAFE AREA AUDIBLE & VISUAL SIGNALLING PRODUCTS SAFE AREA AUDIBLE & VISUAL SIGNALLING PRODUCTS Document No. Date Rev. STD-SEMCO-T-LA-0003 08/12-2011 1 www.semcomaritime.com Contents Contact sheet - Component Sales & Logistics... 3 Daily Support - DK...

More information

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas UL 1203 CSA C22.2 NO. 30-M1986 The D1xS1 and D1xS2 Alarm Horns also comply with the following standards for signaling

More information

E2S Datasheet v10a

E2S Datasheet v10a E2S Datasheet 1.2.3 v10a ISmC1 ISminialert The ISmC1 is a compact combined 100dB(A) alarm sounder and L.E.D. beacon only one Zener barrier or galvanic isolator required to run both sounder & beacon or

More information

EFBW series - BiWire Ultra control panel

EFBW series - BiWire Ultra control panel 4.2 Control panels and repeater panels EFBW series - BiWire Ultra control panel Eaton s new BiWire Ultra fire detection system is unlike any other standard conventional system as the panel, conventional

More information

Addressable Loop Powered Visual Alarm Devices

Addressable Loop Powered Visual Alarm Devices Addressable Loop Powered Visual Alarm Devices About Who is? has a long and proud tradition in fire detection. Founded in Munich in 1877 as Elektrotechnische Fabrik Alois it quickly became a recognized

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information

INSTRUCTION MANUAL (ATEX)

INSTRUCTION MANUAL (ATEX) INSTRUCTION MANUAL (ATEX) ISmA1M Minialarm Intrinsically Safe Round ISmA1M Volume Control Tone Generator S3 Tone Selection Switches Fig 1 Simplified block diagram The ISmA1M sounder is CE marked for compliance

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT

More information

Fire Product Catalog

Fire Product Catalog Additional Expansion Modules Fire Product Catalog CLEVER FIRE SOLUTIONS MA 1000 / Analog Addressable Fire Alarm Panel 1 Military Industry Public Buildings Industrial & Commercial Company Profile We are

More information

DB5 Intrinsically Safe Sounder Type DB-5

DB5 Intrinsically Safe Sounder Type DB-5 Operating Instructions RTK Instruments Limited DB5 Intrinsically Safe Sounder Type DB-5 Description The DB5 Sounder is a strong, lightweight warning sounder, CENELEC certified to Ex II 1G EExia IIC T4

More information

4) Intrinsic Safety Certification

4) Intrinsic Safety Certification INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for

More information

Auer - Signal tower ECO Ø70 mm modular

Auer - Signal tower ECO Ø70 mm modular products Panel Signalling Signal Towers - Auer Auer - Signal tower ECO Ø70 mm modular Modular system with bayonet fitting for quick assembly LED or conventional filament lamp for cost sensitive applications

More information

INPUT / OUTPUT MINI MODULES

INPUT / OUTPUT MINI MODULES INPUT / OUTPUT MINI MODULES APPLICATION The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors

More information

Input/Output Modules Data Sheet

Input/Output Modules Data Sheet Input/Output Modules Data Sheet The wide range of input and output modules available from NOTIFIER delivers exceptional flexibility to a NOTIFIER fire detection and alarm system. Using these modules enables

More information

Solution F2. Fire Alarm Control Panels one step ahead.

Solution F2. Fire Alarm Control Panels one step ahead. Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution

More information

Technical Manual for the Horn DB1P UL DB1HP UL

Technical Manual for the Horn DB1P UL DB1HP UL Technical Manual for the Horn DB1P UL DB1HP UL Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibility for damage, loss or expense

More information

Analogue addressable devices

Analogue addressable devices Apollo XP95 Analogue addressable devices from Channel Safety Systems Apollo XP95 Analogue addressable devices The XP95 range of analogue addressable fire detectors is advanced in design, improved in performance

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances UL, ULC Approved* TrueAlert Addressable Notification Appliances Audible Notification Appliances; Multi-Tone Horns with 520 Hz Output Features Individually addressed and controlled TrueAlert ES multi-tone

More information

EN54-23 Beacons & Sounder Beacons

EN54-23 Beacons & Sounder Beacons EN54-23 Beacons & Sounder Beacons In a fire, everyone matters. Sonos Pulse and Nexus Pulse fire beacons ensure that all personnel are notified of fire emergencies. With Pulse Alert Technology, buildings

More information

The EN54 Part 2 and 4 Fire System

The EN54 Part 2 and 4 Fire System Scope of work: To design, supply, install and commission a Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54 Part 2 and 4 Fire

More information

2000 Series Sensors Installation Guide

2000 Series Sensors Installation Guide 2000 Series Sensors Installation Guide Revision 5.1: August 2000 (unreleased) Aritech is a trademark of SLC Technologies B.V. COPYRIGHT SLC Technologies B.V. 2000. All rights reserved. SLC Technologies

More information

Addressable and Conventional Fire Protection

Addressable and Conventional Fire Protection Addressable and Conventional Fire Protection Simply reliable F I R E P R O T E C T I O N The MAGPro and Fireline systems has been created to balance performance, reliability and aesthetics whilst being

More information

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules Application The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors and manual call points,

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features. Wireless Overview www.incitefire.com.au Overview Fundamentals FIREwave is a wireless based family of products which is fully integrated into Hochiki s renowned ESP intelligent hardwired system. This seamless

More information

Vega Devices.

Vega Devices. Vega Devices This document lists the Argus Vega devices that are compatible with the Panels. It also highlights any specific requirements and technical information. Range of Fire Alarm Control The operation

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances UL, ULC Listed* TrueAlert Addressable Notification Appliances Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output Features Individually addressed and controlled multi-tone

More information

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable Protec Protec Fire Detection Pty Ltd Fire Detection - Addressable Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE Fire Detection

More information

System 800 Addressable Fire Detection & Alarm System

System 800 Addressable Fire Detection & Alarm System SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools

More information

MINERVA MZX125 Digital Addressable Fire Detection System

MINERVA MZX125 Digital Addressable Fire Detection System DATASHEET MINERVA MZX125 Digital Addressable Fire Detection System The Minerva MZX125 is a highly featured digital addressable panel with a comprehensive but easy to operate user interface. The system

More information

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions EN54-3:2001+A1:2002+A2:2006 EN54-5:2000+A1:2002 EN54-25:2008 0359 Electro Detectors Ltd. Electro House Edinburgh

More information

FlexSQUARE Square shaped beacons

FlexSQUARE Square shaped beacons FlexSQUARE Square shaped beacons Size comparison Mini/Midi/Maxi Optical LED Permanent Light 5 LED Flashing Light 6 LED EVS 8 Your benefits The compact LED beacon is particularly versatile. With an IP67

More information

ATEX. IECEx. culs GOST-R. VdS

ATEX. IECEx. culs GOST-R. VdS 1. Hazardous Area Signalling 1.11 Intrinsic safety: Visual 1.12 Intrinsic safety: Audible 1.13 Intrinsic safety: Combination 1.14 Intrinsic safety: Manual Call Points 1.21 Explosion / flame proof: Visual

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions EN54-3:2001+A1:2002+A2:2006 EN54-7:2000+A1:2002+A2:2006 EN54-25:2008 0359 Electro Detectors Ltd. Electro

More information

Quick Selection Guide Fire Systems LSN Periphery

Quick Selection Guide Fire Systems LSN Periphery Local SecurityNetwork Easy wiring Auto configuration capability (self-learning mode) Central programming of all device configurations from the panel Flexible network structure (Loop, stub, T-tap & mixed

More information

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology Fire-Cryer Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX Shaping Alarm Technology Fire-Cryer Plus The Fire-Cryer range of voice sounders was first introduced to the market by Vimpex in 1999.

More information

Conventional Fire Alarm System 2014 V1.2

Conventional Fire Alarm System 2014 V1.2 Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel

More information

YO3 - YO4 / YL4 - YO5 / YL5

YO3 - YO4 / YL4 - YO5 / YL5 C l i f f o r d & S n e l l YO3IS YO4IS DIMENSIONS mm 81(3.2 ) 90(3.5 ) YO3 - YO4 / YL4 - YO5 / YL5 Intrinsically Safe Audible and Visual Alarms ATEX YO5IS YL4IS YL5IS 90(3.5 ) 81(3.2 ) MAIN FEATURES BASEEFA

More information

EXTINGUISHING AGENT RELEASE MODULE

EXTINGUISHING AGENT RELEASE MODULE EXTINGUISHING AGENT RELEASE MODULE Operation, Installation & Programming Manual Revision 3.00 Distributors For: 18-20 Brookhollow Ave telephone 02 8850 2888 www.firesense.com.au Baulkham Hills NSW 2153

More information

AU MX Digital Loop Card Installation Instructions

AU MX Digital Loop Card Installation Instructions 4100-6077AU MX Digital Loop Card Installation Instructions Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS - Follow the instructions in this installation manual. These instructions must be followed

More information

IQ8Control C Fire Alarm Panel

IQ8Control C Fire Alarm Panel IQ8Control C Fire Alarm Panel State-of-the-art processor technology Maximum cable length for esserbus: 3,500 m Graphics supported, high performance programming tool Innovative alarm signalling by means

More information

Fire alarm system EBL512 G3

Fire alarm system EBL512 G3 Fire alarm system EBL512 G3 An analog addressable fire alarm system for early detection - without any unwanted alarms. Third generation. www.panasonic-fire-security.com 2010-04-23 Page 1 of 6 The demands

More information

L-Series, Emergency Communication Devices

L-Series, Emergency Communication Devices Notification Appliances L-Series, Emergency Communication Devices Description The L-Series Emergency Communications devices and accessories combine application versatility with all of the same time-saving

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information

Explosion Proof Combination Signal db (A) / 5 Joule

Explosion Proof Combination Signal db (A) / 5 Joule Explosion Proof Combination Signal - Operating instructions Additional languages www.r-stahl.com General information Contents 1 General information...2 1.1 Manufacturer...2 1.2 Information regarding the

More information

The new detector from Rafiki

The new detector from Rafiki The new detector from Rafiki Three smoke detectors Three heat detectors Combined smoke/heat detector Full alarm sounder Strobe End-of-line device/loop isolator Rafiki s Multipoint ASD detector range have

More information

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

DBS721, DBS729 Sounder interbase, Sounder beacon interbase DBS721, DBS729 Sounder interbase, Sounder beacon interbase For the automatic addressable detector bus C-NET Cerberus PRO Sounder interbase DBS721 and sounder beacon interbase DBS729 11 selectable tones,

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information

Interface and EOL Modules 8

Interface and EOL Modules 8 Interface and EOL Modules Interface Modules Series 420 25 Interface Modules Series 100 291 EOL Modules 293 254 Interface and EOL Modules Interface Modules Series 420 Interface Modules Serie 420 Interface

More information

CONVENTIONAL AUDIBLE VISUAL

CONVENTIONAL AUDIBLE VISUAL Fast Installation, Safe Evacuation CONVENTIONAL AUDIBLE VISUAL www.kac.co.uk Setting the Standard with ENscape EN54-23 and how it affects you EN54-23 is a new European standard for Visual Alarm Devices

More information

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication FDS229-R / FDS229-A Alarm sounder with supplementary optical indication For the automatic addressable detector bus C-NET and FDnet Cerberus PRO Sinteso Alarm sounder with 11 tonalities selectable, 2 activation

More information

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable Protec Fire Detection - Addressable Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE Fire Detection - Addressable Protec Protec Algo-TecTM

More information

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System DIVA8MG2 Public Address - Voice Alarm Audio Distribution over IP Commercial Audio Intelligent Acoustic Solutions Intercommunication Loudspeakers Compact PAVA System Master Unit DIVA8 System DIVA8 system

More information

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy. Installation manual detector and controller Code no. 20711062 Page 1/30 CONTENTS Controller... 2 Function of the Relays... 2 Gas Detectors... 2 Cabling... 4 Mechanical Installation of the gas detectors...

More information

L-Series, Indoor Strobes and Horn Strobes

L-Series, Indoor Strobes and Horn Strobes Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Horns, Strobes and Horn Strobes for Wall Applications General The L-Series audible visible notification products

More information

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E SpectrAlert Advance Description System Sensor SpectrAlert Advance offers a variety of devices designed for mass notification, including plain devices for non-fire applications, amber lens strobes and speaker

More information

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 ANALOGUE FIRE DETECTION VIGILON COMPACT FEATURES & BENEFITS four Keep it Simple All Vigilon devices connect onto the same 2

More information

Evacuate everyone Sonos Pulse & Nexus Pulse

Evacuate everyone Sonos Pulse & Nexus Pulse Evacuate everyone Sonos Pulse & Nexus Pulse Available through distribution: www.discountfiresupplies.co.uk Tel: 01792 452 700 EN54-23 Fire Beacons In a fire, everyone matters. Sonos Pulse and Nexus Pulse

More information

AUDIBLE SIGNALIZATION

AUDIBLE SIGNALIZATION 01 SIGNALIZATION AUDIBLE SIGNALIZATION PROGRAMMABLE ELECTRONIC MULTITONE SIRENS WITH TWO INPUTS Specially designed for marine application With two inputs where using each one, different tones and frequency

More information

L-Series, Indoor Strobes and Horn Strobes

L-Series, Indoor Strobes and Horn Strobes Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Strobes/Horn Strobes for Ceiling Applications General The L-Series audible visible notification products offer

More information

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23 Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices Approved to EN54-3/EN54-23 Setting the Standard EN54-23 and how it affects you EN54-23 is a new European standard for Visual Alarm

More information

Half-Dome. the Design-Tower. Compact

Half-Dome. the Design-Tower. Compact the Design-Tower 81 Compact 82 compact signal towers Visual-audible LED signal tower system in semicircular design Modern signal tower design Available to order pre-configured or with customised tower

More information

Evolution Analogue Addressable Fire System

Evolution Analogue Addressable Fire System Addressable Fire System optimum fire safety systems solutions High speed FSK protocol, uniquely resistant to noise Up to 254 addresses per loop for flexible system design Built to exceptional marine standards

More information

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1. Data Sheet Ref: 90501085 WD-CS Water leak detection cable Technical Overview The WD-CS range of cable sensors are typically used to detect water leaks usually under floors, and are used in conjunction

More information

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet Table 1: Models Description Low frequency (520 Hz) horn, white housing, no FIRE marking, standard output clear strobe light Low frequency (520

More information

Synova TM product catalog.

Synova TM product catalog. Synova product catalog Synova TM product catalog. Fire protection products and accessories. Siemens Switzerland Ltd Building Technologies Group International Headquarters Gubelstrasse 22 CH-6301 Zug Tel

More information