1 Hazardous Area Electrical Equipment Made TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22 Index Dimension Sheet Catalogue Information Leaflet Web Links TBSF/CBSF Information Page Ask a question / Send us an enquiry Information about B&R Local Sales Team Phone Numbers B&R Enclosures Pty Ltd, PO Box 1151, Browns Plains BC, QLD 4118 Ph Fax
2 Technical Drawings B G E C F A I H ø8.5 hole size D 6mm earth stud Front View Front View With Internals Side View Dimensions (mm) External Fixings Opening No of Catalogue No. A B C D E F G H I Fixings TBSF TBSF TBSF TBSF TBSF The above enclosures are sold with controls and terminals fitted. Contact your sales representative to discuss your project requirements.
3 TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1 & 2, 21 & 22 brenclosures.com.au/tbks.htm Made Certification number: IECEx ITA x Features Customised etched identification label Protection Ex e IIC T6 Gb Ex na IIC T6 Gc, Zone 2 only Ex de IIC T6 Gb Ex td A21/22 T80ºC DIP A21/22 Ta80ºC Ex t IIIC T80ºC Db Ambient temperature -20ºC ~ +40ºC Conformity IEC , IEC IEC , IEC Materials Body 316 stainless steel Body thickness 1.5mm Gasket Neoprene Fixings 316 stainless steel Surface finish N4 Protection rating IP65, IP66 and IP67 The flat roof screwed terminal box is constructed from 316 stainless steel and is suitable for use in hazardous areas with the most demanding conditions. These enclosures are designed to house terminals, electrical equipment and cable terminations in Zone 1, Zone 2, Zone 21 and Zone 22 applications where flammable liquids, gases & vapours or combustible dusts are frequently present. Inclusions Earth strap kit External earth stud Mounting flanges Selection Guide Dimensions (mm) Catalogue No. Depth Usable Depth TBSF TBSF TBSF TBSF TBSF The above enclosures are sold with controls and terminals fitted. Contact one of our sales engineers to discuss project requirements. Contact Block Pushbuttons Switches 132 Hazardous Area Electrical Equipment For technical drawings see page 243
4 ENCLOSURES SS TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Ex e, Ex na, Ex de, Ex td, DIP & Ex t Protection Zones 1 & 2, 21 & 22 IP65/66/67 Made Protection: Ex e IIC T6 Gb Ex na IIC T6 Gc, Zone 2 only Ex de IIC T6 Gb Ex td A21/22 T80ºC DIP A21/22 Ta80ºC Ex t IIIC T80ºC Db Ambient Temperature: -20ºC ~ +40ºC Conformity: IEC , IEC IEC , IEC Certification number: IECEx ITA x OVERVIEW MATERIALS The flat roof screwed terminal box is made from 316 stainless steel and is suitable for use in hazardous areas with the most demanding conditions. These enclosures are suitable for Zones 1 and 2, 21 and 22 applications where flammable liquids, gases & vapours or combustible dusts are frequently present. Body: 316 stainless steel Body thickness: 1.5mm Gasket: Neoprene Fixings: 316 stainless steel Surface finish: N4 APPLICATION FEATURES Designed to house terminals, electrical equipment and cable terminations in areas classified hazardous by the presence of flammable liquids, gases and vapours or combustible dusts. IP65, IP66 and IP67 protection rating Customised etched identification label Screwed lid Mounting flanges 3mm stainless steel gland plate External earth stud Stainless steel fixings Earth strap kit
5 ENCLOSURES SS TBSF/CBSF CATALOGUE INFO Catalogue No. (H1) (W1) Dimensions (mm) Fixings (mm) Opening (mm) Depth (D1) Usable Depth (D3) Distance From Wall (D2) TBSF TBSF TBSF TBSF TBSF The above enclosures are sold with controls and terminals fitted. Contact your local sales engineer to discuss project requirements. (F1) (F2) (H3) (W3) No of Fixings TECHNICAL DRAWINGS W1 F2 D2 D1 F1 H1 W3 H3 ø8.5 hole size D3 6mm earth stud INCLUSIONS The TBSF flat roof screwed terminal box can be customised to suit your requirements by the fitting of control gear/operators, entries and terminals. Example of Controls/Operators available: Pushbuttons Emergency Stop Operator Isolator Switches Key Switches Pilot Lights Terminals Ammeters Voltmeters Circuit Breakers DISCLAIMER: For information only. Refer to certificate of conformity or contact our technical department for detailed product information. Other brands in the B&R Group: Queensland P: South Australia P: sales@brenclosures.com.au Townsville P: Western Australia P: Web Sydney P: Tasmania P: Newcastle P: Northern Territory P: Victoria P: CJ/BB
IECEx Certificate of Conformity
Certificate of Conformity: IECEx SIR 09.0111 http://iecex.iec.ch/iecex/iecexweb.nsf/fc034777969a786bc1256d42005bd791/f076962... Page 1 of 3 22/01/2010 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL
More informationEN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures
EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures HDL-3-EX* Complete and ready to install Heat Detector with Ex-certified Box, Cable gland and wiring
More informationINSTRUCTION & SERVICE MANUAL
INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following
More informationSOLUZIONI PER ATMOSFERA ESPLOSIVA
catalogo ATEX 2015 SOLUZIONI PER ATMOSFERA ESPLOSIVA ATEX catalogue book 2016 SOLUTIONS FOR EXPLOSIVE ATMOSPHERES Since 1904 In 1904 PALAZZOLI began its activity in Brescia when electrical energy was first
More informationofficial distributor of Newson Gale Ltd.
Continuous Ground Loop Monitoring with visual indication. The precision and reliability of the provides enhanced safety and security by continuously testing the connection of the clamp to the container
More informationErik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories
Hazardous Locations: Understanding the Basics of Global Compliance Requirements Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories DISCLAIMER/ TERMS OF USE: THE INFORMATION
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBG15E and BExBG10E Flameproof / Increased Safety Xenon Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG15E and BExBG10E beacons are flameproof
More informationTYPE APPROVAL CERTIFICATE
TYPE APPROVAL CERTIFICATE Certificate No: E-14378 This is to certify: That the Pilot Device with type designation(s) Pilot device Issued to BARTEC GmbH BAD MERGENTHEIM, Germany is found to comply with
More informationmanual addendum DELPHI Ex
manual addendum DELPHI Ex II 2G Ex eb IIC T4 Gb II 2D Ex tb IIIC T135 C IP65 Db Tamb=-20 +40 C Reference list: Norm (last issue) Title Dir. 2014/34/UE EN 60079-31 EN60079-0 EN60079-7 Equipment and Protective
More informationIECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection
IECEx International Conference 2017 Shanghai, China Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2017 Peter Thurnherr Shanghai thuba Electric Co. Ltd.,
More informationINSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS Please read these instructions thoroughly before installation and ensure they are passed on to
More informationBoth enclosures provide an IP 66 degree of ingress protection and are suitable for both indoor and outdoor installation.
Continuous Ground Loop Monitoring with visual indication. The precision and reliability of the provides enhanced safety and security by continuously testing the connection of the clamp to the container
More informationIllumination unit For sight glass level indicator Model LGI
Level Illumination unit For sight glass level indicator Model LGI WIKA data sheet LM 33.02 for further approvals see page 2 Applications Better identification of liquid and gaseous phase Direct indication
More informationINSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations
INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING
More informationREGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC
EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or
More informationManual Power relay SR853
Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death
More informationUSER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218
CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.
More informationFlameproof Manual Call Points Series MCP
> Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied
More informationOfficine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0
Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2557738 Master Contract: 256526 Issued to: Bartec Varnost d.o.o Cesta 9 avgusta 59 Zagorje ob Savi, 1410 Slovenia Attention: Janez Gajski The products listed below
More informationCertificate of Compliance
FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296
More informationGuide for hazardous areas
Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection
More informationElectrical Installations Design, Selection, Erection and Inspection
IECEx International Conference 2018 Jakarta, Indonesia Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Peter Thurnherr thuba Ltd.,
More informationProduct manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands
Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these instructions
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm
More informationHazardous Areas - EXPLOSIONPROOF SOLENOIDS
Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas
More informationExplosion-proof Immersion Heater Type D-8660
Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to
More informationCertificate of Compliance
FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The
More informationATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES
ATEX catalogue book 20172018 SOLUTIONS FOR EXPLOSIVE ATMOSPHERES Since 1904 In 1904 PALAZZOLI began its activity in Brescia when electrical energy was first used in the industry. The Company is specialized
More informationINSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations
INSTRUCTION MANUAL D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations synchronization requirements of UL1971 & UL1638 / CAN/ULCS526. 2.2 NEC & CEC Class / Division Ratings for US / Canada
More informationINSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres
INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified
More informationUSER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236
CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.
More informationRegulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D
Regulated Ex-Heater HEX5-1.08 with internal controller, HEX5-2.08 with external controller II 3 G II 3 D Instruction Manual Version 1.02.00 Dear customer, we have made up this operating manual in such
More informationExplosion Proof Manual Call Points Series MCP
> Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied
More informationCCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.
Ex d CCAC - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66 Stainless steel bolts Polyester coating External earth screw Grub screws for opening lid External earth screw
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT
More informationINSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS Please read these instructions thoroughly before installation and ensure they are passed on to the end-user 1 1.0
More informationEJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67
Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket
More informationARRAN LED LED FLOODLIGHT. Standard Specification. Features
ARRAN LED LED FLOODLIGHT The Arran LED floodlight range is low energy with an instant on output and up to 130,000 maintenance free hours. Specifically designed for applications where moisture, dirt or
More informationstandards: standards:
INSTRUCTION MANUAL D2xB1LD2 LED Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD
More informationDTS Light fittings for explosive atmospheres
DTS Light fittings for explosive atmospheres For all zones and industrial applications LIGHT FITTINGS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones and industrial applications Tubular glass light
More informationINSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon
INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing
More informationCertification Supplement Manual
PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY
More informationFan Heaters Type VLEx
Fan Heaters Type VLEx Fan Heater type VLEx has been designed for Explosion Proof industrial applications. Our Fan Heaters are characterized mainly by their quality, both in used materials and design. Liquids
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MNUL (TEX / IECEx) ExG21D Flameproof Xenon eacon For use in Flammable Gas and Dust tmospheres 1) Introduction The ExG21D is a flameproof beacon certified to meet the requirements of the TEX
More informationInductive slot sensor
0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationUL HAZARDOUS LOCATIONS SERVICES
UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,
More informationARGENTA ATEX For potentially explosive atmospheres. ARGENTA ATEX Technical Specifications Wall-mounting cabinets. ARGENTA ATEX Certifications
For potentially explosive atmospheres IDE presents its ATEX certified product range, specially intended for potentially explosive atmospheres, where the degree of protection and strength must be maximised.
More informationOPTIBAR DP 7060 Supplementary Instructions
OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,
More informationUser manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc
User manual Explosion-safe window air conditioning system Type series AR-054 II 3 G Ex ic nac h IIC T3 Gc 1. Safety Instructions The window air conditioning series AR-054 is an explosion-safe product suitable
More informationSAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series
Pag. 1/6 Enclosure for asynchronous electric motors Series LEX 80,90,100,112,132,160,180,200,225,250,280,315 and 355 Ex na, Ex td execution II 3G, II 2D SAFETY INSTRUCTIONS euromotori motori elettrici
More informationDrive systems for the chemical, oil and gas industry. Electric drives and systems
Drive systems for the chemical, oil and gas industry Electric drives and systems 2 VEM drive systems for the chemical, oil and gas industry VEM drive systems for the chemical, oil and gas industry 3 VEM
More informationTECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:
Page 1 of 9 TECHNICL MNUL EXPLOSION PROOF STTUS LIGHT / LMP TEX Marking: Code: II 2GD EPL Gb, Db Ex d IIC T4/T5/T6 IP66 Ex tb IIIC TXXX C Marking details: Please note that every care has been taken to
More informationCertification Supplement Manual
PROCESS ANALYSERS SERVOTOUGH Oxy Gas Analyser Certification Supplement Manual Part Number: 01910008B Revision: 9 Language: UK English This page intentionally blank SERVOTOUGH Oxy Certification Supplement
More informationTHE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS
THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS A Worldwide Manufacturer of Process Analyzers and Instrumentation RELIABILITY EXPERIENCE SOLUTIONS AMETEK Process Instruments is a worldwide
More informationExPolar Heating System
ExPolar Heating System for use with Max actuators and Cos / Bin / Reg sensors in extreme temperatures to 50 C ATEX certified in acc. with directive 201 / / EU for use in zones 1, 2, 21 and 22 ExPolar -...
More informationDB4 Range - SPEAKERS - Up to 25 Watts
DB Range - SPEAKERS - Up to 5 Watts Hazardous Location, Weatherproof Features UL listed for USA and Canada Class I, Div, Groups A, B, C & D. Class I, Zone, AExd IIC T. CSFM approved. ATEX approved. NEMA
More informationOPTIBAR P 1010/2010 C Supplementary instructions
OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions
More informationApprovals, Certificates and Conditions
PROCESS ANALYSERS SERVOTOUGH SpectraExact (2500 series) Process Gas Analysers Approvals, Certificates and Conditions Part Number: Revision: Language: 02500008C 4 UK English This page intentionally blank
More informationATM Lighting sp. z o.o
INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL210LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
More informationIECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements
ExTR Reference Number...: ExTR Free Reference Number...: 223531 Compiled by + signature (ExTL)...: Reviewed by + signature (ExTL)...: NO/NEM/ExTR12.0018/00 Stig André Norheim Arne Hortman Date of issue...:
More informationINSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS STW & STW-T SAFE AREA AIR WARMERS HFT, AFT & SAT TYPE AIR THERMOSTATS Please read these
More informationIntegrated Solutions Low Voltage Systems
Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx
More informationINERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)
FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries
More informationGas cylinder scale Model GCS-1
Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in
More informationCertification Supplement Manual
SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 5 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EU DECLARATION OF CONFORMITY 3 EUROPEAN
More informationEXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X
EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ15.1138X Manufacturer: Product: Model Specification: Anti-explosion Mark: Topworx Inc. (Address: 3300 Fern Valley Road, Louisville, Kentucky
More informationAS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
Skip to main content Skip to primary navigation Home Home About this portal Latest updates Menu Print Save Email Resource detail Citations AS/NZS 60079.14:2009 Explosive atmospheres - Part 14: Electrical
More informationCOMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)
COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX) TECHNICAL DESCRIPTION EDITION: TB CFC200-REV3-2015-04-07 IMPORTANT: Please note, that all mounting and wiring as well as all changing or adjustment at the
More informationFixed Gas Detection System/Meridian CERTIFICATION
The marking shall include 2 Wire Aluminum Transmitter 3/4 Wire Aluminum Transmitter 2 Wire Stainless Steel Transmitter (PN: 096-3521) (PN: 096-3522) (PN: 096-3525) Ex db [ia Ga] IIC T4 Gb Ex db [ia Ga]
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:1 Status:
More informationIECEx Certificate of Conformity
Page 1 of 4 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate
More informationImmersion heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI100EN 09/2017
More informationCirculation heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI500EN 09/2017
More informationHazardous Area Portable Fan Heater The Bulldog
Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable
More informationIntrinsically Safe Solutions
Intrinsically Safe Solutions INSTALLATION MANUAL 04/12/14 Rev D DOC-01-029 Documentation Feedback Your feedback helps us keep our documentation up to date and accurate. If you have any comments or suggestions
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationDräger Polytron 5200 CAT Detection of flammable gases and vapours
Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion
More informationELECTRICAL EX EQUIPMENT
ELECTRICAL EX EQUIPMENT in hazardous areas Enclosures Reliable Customized Solutions Leader in Explosion Proof Protections CB Control Panel Configuration - Gas group IIB / Dust group IIIC Ex d enclosures
More informationPRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres
PRODUCT OVERVIEW Light fittings, boxes & custom built control panels for explosive atmospheres LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones
More informationATM Lighting sp. z o.o
INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL390LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,
More informationGRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S
www.stahl.de > Corrosion resistant omnidirectional high output sounder > Integrated Ex d enclosure > Extreme temperature range > 3 stage alarm with independant tone selection for V DC systems > IP66 IP67
More informationDräger Polytron 8310 IR Detection of flammable gases and vapour
Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationDräger PIR 3000 Detection of flammable gases and vapours
Dräger PIR 3000 Detection of flammable gases and vapours The Dräger PIR 3000 is an explosion proof infrared gas detector for continuous monitoring of combustible gases and vapors Based on a stainless steel
More information4) Intrinsic Safety Certification
INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for
More informationEUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU
EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU GENERAL The accidental ignition of an atmosphere containing a large quantity of gas, vapour, mists and/or dust may cause an explosion. Specific
More informationMTRA-FSP Level Control Relay. Installation & Operation Manual
MTRA-FSP Level Control Relay Installation & Operation Manual This Manual is the support documentation for the installation, commissioning and operation of the MTRA-FSP Level Control Relay. Document Revision
More informationDrive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors
Drive Technology \ Drive Automation \ System Integration \ Services *23511257_0817* Inquiry Forms for Explosion-Proof Gearmotors Edition 08/2017 23511257/EN SEW-EURODRIVE Driving the world Inquiry forms
More informationHazardous Area Portable Fan Heater The Bulldog
Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable
More informationDräger Polytron 5700 IR Detection of flammable gases and vapours
Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive
More informationInspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN
Inspection Light LED Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3 Conformity
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationTechnical Data. Dimensions
0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element
More informationTrusted worldwide since 1989 INTRINSICALLY SAFE RANGE
Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting systems. Our main objective is to offer high
More informationEarth-Rite II PLUS Static Earthing System
READ MANUAL BEFORE COMMENCING WITH INSTALLATION EN Earth-Rite II PLUS Static Earthing System P1 PLUS - DC Supply Installation & Operating Instructions The safety of any system incorporating the equipment
More informationRTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ
Operating Instructions RTK Instruments Limited PEX7250 Explosion Proof Annunciator Introduction This manual provides the information necessary to install, connect, test and maintain the PEX7250 Explosion
More informationDräger Polytron 8310 Stationary gas detector (DSIR)
Stationary gas detector (DSIR) SIMPLE INSTRUMENT MANAGEMENT POISON-RESISTANT AND FAIL-SAFE THANKS TO DIGITAL COMMUNICATION The DrägerSensor IR offers several benefits: technological advantages such as
More information