Enclosure Cooling, Venting, Heating & Purging Solutions. Celebrating 20 Years of Excellence

Size: px
Start display at page:

Download "Enclosure Cooling, Venting, Heating & Purging Solutions. Celebrating 20 Years of Excellence"

Transcription

1 Enclosure Cooling, Venting, Heating & Purging Solutions Celebrating 20 Years of Excellence

2 Enclosure Climate Control Table of Contents Closed Loop Air Conditioners Pgs 3-18 Thermoelectric Cooling Pgs Filtered Fan Packages Pgs Purge and Pressurization Pgs Cooling electrical enclosures is our business. Whether you require lower than ambient cooling or slightly above, we provide proven products that will allow you to protect your electronics and avoid costly temperature and debris related production shutdowns. Heaters and Controllers Pg Vortex Cooling Pgs 24-26

3 ISC Enclosure Air Conditioners 1,000 BTUH - 20,000 BTUH MODELS Compact, Narrow, High Capacity and Wide Footprint Models available to satisfy a wide range of application requirements. 3 Indoor/Outdoor NEMA Type 12, 4 and 4X UL/cUL Closed Loop Systems Digital Temperature Controller Programmable set point and temperature operating controls Visible error and/or alarm messaging System status indication Password protection Independent Active Condensate Management System Elimination of condensate Eradicates condensate without corrosive contact with coils Unit Efficiency Pressure operated blower control reduces power inrush and saves energy High efficiency Non-CFC refrigerant Fully insulated & sealed cabinet Temperature Control Valve to provide a broad temperature range while maintaining cooling capacity 100% factory tested Industrial Construction Free standing rigid chassis eases maintenance Durable 16 gauge welded steel construction with a hard wearing powder coated finish for NEMA Type 12 and 4; 304 Stainless Steel for NEMA Type 4X Compressor Protection System High & Low refrigerant cutoffs with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power inrush, save energy and increase compressor life Engineered & manufactured to endure the most difficult of environments and applications. ISC air conditioners will exceed environmental requirements in applications like Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics. Options: High Ambient Package on Specified Units Corrosive Environment Package External Alarm Capabilities Dry Contact Remote Monitoring Options Integrated Enclosure Heater System Low Ambient Protection NEMA Type 12, 4 and 4X Available Hazardous area models 316 Stainless Steel Construction Remote Programmable Controller 1 Year Warranty Master Part Number Scheme ISC - NE XXX 1. ISC Plano, TX Celebrating 20 Years of Excellence Maintains UL/cUL Type 12, 4 or 4X rating when properly installed on a UL/cUL Type 12, 4 or 4 X rated enclosure. UL/cUL Listed; File No. SA Depicts the series of the air conditioner. CS = Compact, NE = Narrow Edge, HC = High Capacity, WF = Wide Footprint 3. This is the BTUH capacity, 080 = 8,000 BTUH 4. Voltage and Hz. 126 = 120/60, 236 = 230/60, 486 = 480/60 5. NEMA Type 12, 04, 4X 6. A unique set of numbers for each air conditioner which identifies the accessories on a model 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

4 ENCLOSURE AIR CONDITIONERS Narrow Edge Series 1000 BTUH BTUH MODELS Designed to fit 12in. Panels Indoor/Outdoor NEMA Type 12, 4 and 4X Closed Loop Systems Unique Condensate Management System evaporates moisture from the enclosure thus eliminating drain tubes, buckets, and wet floors in typical applications. Compressor Protection System includes high and low refrigerant cutoffs with fault protection, anti short cycle protection, and compressor run capacitors to increase compressor life and save energy. Highly Efficient with fully insulated and sealed cabinets, and pressure operated blowers that reduce power inrush and saves energy. Digital Temperature Controller with programmable set points, visible error and/or alarm messaging and system status indication. Maintains UL/cUL Type 12, 4 or 4X rating when properly installed on a UL/cUL Type 12, 4 or 4 X rated enclosure. UL/cUL Listed; File No. SA8067 SPECIFICATIONS Part Number BTUH Watts Volts /Hz. Running Amps Max Ambient Temperature Information Subject to change without notice Dimensions H x W x D ISC-NE XX-XXX / F 22 x11.8 x ISC-NE XX-XXX / F 22 x11.8 x ISC-NE XX-XXX / F 22 x11.8 x ISC-NE XX-XXX / F 22 x11.8 x ISC-NE XX-XXX / F 32 x11.8 x ISC-NE XX-XXX / F 32 x11.8 x Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com Net Weight ISC-NE XX-XXX / F x11.8 x ISC-NE XX-XXX / F 32 x11.8 x ISC-NE XX-XXX / F 32 x11.8 x ISC-NE XX-XXX / F x11.8 x ISC-NE XX-XXX / F 32 x11.8 x ISC-NE XX-XXX / F 32 x11.8 x ISC-NE XX-XXX / F x11.8 x ISC-NE XX-XXX / F 36 x11.8 x15 85 ISC-NE XX-XXX / F 36 x11.8 x15 85 ISC-NE XX-XXX / F x11.8 x ISC-NE XX-XXX / F 36 x11.8 x15 85 ISC-NE XX-XXX / F 36 x11.8 x15 85 ISC-NE XX-XXX / F x11.8 x ISC-NE XX-XXX / F 36 x11.8 x15 90 ISC-NE XX-XXX / F 36 x11.8 x15 90 ISC-NE XX-XXX / F x11.8 x15 150

5 ENCLOSURE AIR CONDITIONERS Narrow Edge Series 2,000, 3000, 4,000 BTUH 480 VAC Celebrating 20 Years Of Excellence Engineered & manufactured to endure the most difficult of environments and applications. ISC air conditioners will exceed environmental requirements in applications like Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics 2,000 BTUH - 4,000 BTUH MODELS Designed to fit 12in. Panels Indoor/Outdoor NEMA Type 12, 4 and 4X Closed Loop Systems Options: High Ambient Package Corrosive Environment Protection External Alarm Capabilities Dry Contact Remote Monitoring Integrated Enclosure Heater System Low Ambient Protection NEMA Type 12, 4 and 4X Hazardous Areas Models 316 Stainless Steel Construction Oversized Air Filters Remote Programmable Controller Digital Temperature Controller Programmable set point and temperature operating controls Visible error and/or alarm messaging System status indication Password protection Independent Active Condensate Management System Elimination of condensate Eradicates condensate without corrosive contact with coils Unit Efficiency Pressure operated blower control reduces power inrush and saves energy Fully insulated & sealed cabinet Temperature Control Valve to provide a broad temperature range while maintaining cooling capacity 100% factory tested Industrial Construction Free standing rigid chassis eases maintenance Durable 16 gauge welded steel construction with a hard wearing powder coated finish for NEMA Type 12 and 4; 304 Stainless Steel for NEMA Type 4X Compressor Protection System High & Low refrigerant cutoffs with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power inrush, save energy and increase compressor life 1 Year Warranty Part Number BTUH Watts Volts/Hz. Running Amps Max Ambient Temperature Dimensions H x W x D Net Weight ISC-NE XX-XXX / F x 11.8 x 9.5 ISC-NE XX-XXX / F x 11.8 x 9.5 ISC-NE XX-XXX / F x 11.8 x Information Subject to change without notice 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

6 ENCLOSURE AIR CONDITIONERS Narrow Edge Series 5,000, 6000, 8,000 BTUH 480 VAC Celebrating 20 Years Of Excellence Engineered & manufactured to endure the most difficult of environments and applications. ISC air conditioners will exceed environmental requirements in applications like Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics 5,000 BTUH - 8,000 BTUH MODELS Designed to fit 12in. Panels Indoor/Outdoor NEMA Type 12, 4 and 4X Closed Loop Systems Options: High Ambient Package Corrosive Environment Protection External Alarm Capabilities Dry Contact Remote Monitoring Integrated Enclosure Heater System Low Ambient Protection NEMA Type 12, 4 and 4X Hazardous Areas Models 316 Stainless Steel Construction Oversized Air Filters Remote Programmable Controller Digital Temperature Controller Programmable set point and temperature operating controls Visible error and/or alarm messaging System status indication Password protection Independent Active Condensate Management System Elimination of condensate Eradicates condensate without corrosive contact with coils Unit Efficiency Pressure operated blower control reduces power inrush and saves energy Fully insulated & sealed cabinet Temperature Control Valve to provide a broad temperature range while maintaining cooling capacity 100% factory tested Industrial Construction Free standing rigid chassis eases maintenance Durable 16 gauge welded steel construction with a hard wearing powder coated finish for NEMA Type 12 and 4; 304 Stainless Steel for NEMA Type 4X Compressor Protection System High & Low refrigerant cutoffs with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power inrush, save energy and increase compressor life 1 Year Warranty Part Number BTUH Watts Volts/Hz. Running Amps Max Ambient Temperature Dimensions H x W x D Net Weight ISC-NE XX-XXX 5,000 1, / F x 11.8 x 15 ISC-NE XX-XXX 6,000 1, / F x 11.8 x 15 ISC-NE XX-XXX 8,000 2, / F x 11.8 x Information Subject to change without notice 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

7 ENCLOSURE AIR CONDITIONERS Compact Series 2,000 BTUH MODELS Designed to Fit 10 in. Enclosures Indoor/Outdoor NEMA Type 12, 4 and 4X Closed Loop Systems Unique Condensate Management System evaporates moisture from the enclosure thus eliminating drain tubes, buckets, and wet floors in typical applications. Compressor Protection System includes high and low refrigerant cutoffs with fault protection, anti short cycle protection, and compressor run capacitors to increase compressor life and save energy. Highly Efficient with fully insulated and sealed cabinets, and pressure operated blowers that reduce power inrush and saves energy. Digital Temperature Controller with programmable set points, visible error and/or alarm messaging and system status indication. Maintains UL/cUL Type 12, 4 or 4X rating when properly installed on a UL/cUL Type 12, 4 or 4 X rated enclosure. UL/cUL Listed; File No. SA8067 SPECIFICATIONS Part Number BTUH Watts Volts /Hz. Running Amps Max Ambient Temperature Dimensions H x W x D Net Weight ISC-CS XXX / F 20 x10 x10 44 ISC-CS XXX / F 20 x10 x10 44 ISC-CS XXX / F 20 x10 x10 44 ISC-CS XXX / F 20 x10 x10 44 ISC-CS X-XXX / F 20 x10 x10 44 ISC-CS X-XXX / F 20 x10 x10 44 Information Subject to change without notice 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

8 ENCLOSURE AIR CONDITIONERS WF Series 6,000 & 8,000 BTUH MODELS Designed to Fit Enclosures Requiring a Smaller Depth A/C Indoor/Outdoor NEMA Type 12, 4 and 4X Closed Loop Systems Unique Condensate Management System evaporates moisture from the enclosure thus eliminating drain tubes, buckets, and wet floors in typical applications. Compressor Protection System includes high and low refrigerant cutoffs with fault protection, anti short cycle protection, and compressor run capacitors to increase compressor life and save energy. Highly Efficient with fully insulated and sealed cabinets, and pressure operated blowers that reduce power inrush and saves energy. Digital Temperature Controller with programmable set points, visible error and/or alarm messaging and system status indication. Maintains UL/cUL Type 12, 4 or 4X rating when properly installed on a UL/cUL Type 12, 4 or 4 X rated enclosure. UL/cUL Listed; File No. SA8067 SPECIFICATIONS Part Number BTUH Watts Volts /Hz. Running Amps Max Ambient Temperature Dimensions H x W x D Net Weight ISC-WF XXX / F x19 x ISC-WF XXX / F x19 x ISC-WF XXX / F x19 x ISC-WF XXX / F x19 x ISC-WF X-XXX / F x19 x ISC-WF X-XXX / F x19 x ISC-WF XXX / F x19 x ISC-WF XXX / F x19 x ISC-WF XXX / F x19 x ISC-WF XXX / F x19 x ISC-WF X-XXX / F x19 x ISC-WF X-XXX / F x19 x Information Subject to change without notice 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

9 ENCLOSURE AIR CONDITIONER WF Series 6,000 BTUH Celebrating 20 Years 20 of Excellence Years Engineered & manufactured to endure the most difficult of environments and applications. ISC air conditioners will exceed environmental requirements in applications like Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics Options: High Ambient Package Corrosive Environment Protection External Alarm Capabilities Dry Contact Remote Monitoring Integrated Enclosure Heater System Low Ambient Protection NEMA Type 12, 4 and 4X Hazardous Area Models 316 Stainless Steel Construction Remote Programmable Controller Indoor/Outdoor NEMA Type 12, 4 and 4X Closed Loop System Digital Temperature Controller Programmable set point and temperature operating controls Visible error and/or alarm messaging System status indication Password protection Independent Active Condensate Management System Elimination of condensate Eradicates condensate without corrosive contact with coils Unit Efficiency Pressure operated blower control reduces power inrush and saves energy Fully insulated & sealed cabinet Temperature Control Valve to provide a broad temperature range while maintaining cooling capacity Washable Filter Media Industrial Construction Free standing rigid chassis eases maintenance Durable 16 gauge welded steel construction with a hard wearing powder coated finish for NEMA Type 12 and 4; 304 Stainless Steel for NEMA Type 4X Tamper Resistant Hardware Compressor Protection System High & Low refrigerant cutoffs with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power inrush, save energy and increase compressor life 1 Year Warranty Part Number NEMA Type BTUH Watts Volts/ Hz. Running Amps Max Ambient Temperature Dimensions H x W x D Net Weight ISC-WF XX-XXX 12,04,4X 6,000 1, / F x 19 x ISC-WF XX-XXX 12,04,4X 6,000 1, / F x 19 x Information Subject to change without notice 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

10 ENCLOSURE AIR CONDITIONER WF Series 8,000 BTUH Celebrating 20 Years of Excellence Engineered & manufactured to endure the most difficult of environments and applications. ISC air conditioners will exceed environmental requirements in applications like Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics Options: High Ambient Package Corrosive Environment Protection External Alarm Capabilities Dry Contact Remote Monitoring Integrated Enclosure Heater System Low Ambient Protection NEMA Type 12, 4 and 4X Hazardous Area Models 316 Stainless Steel Construction Remote Programmable Controller Indoor/Outdoor NEMA Type 12, 4 and 4X Closed Loop System Digital Temperature Controller Programmable set point and temperature operating controls Visible error and/or alarm messaging System status indication Password protection Independent Active Condensate Management System Elimination of condensate Eradicates condensate without corrosive contact with coils Unit Efficiency Pressure operated blower control reduces power inrush and saves energy Fully insulated & sealed cabinet Temperature Control Valve to provide a broad temperature range while maintaining cooling capacity Washable Filter Media Industrial Construction Free standing rigid chassis eases maintenance Durable 16 gauge welded steel construction with a hard wearing powder coated finish for NEMA Type 12 and 4; 304 Stainless Steel for NEMA Type 4X Tamper Resistant Hardware Compressor Protection System High & Low refrigerant cutoffs with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power inrush, save energy and increase compressor life 1 Year Warranty Part Number NEMA Type BTUH Watts Volts/ Hz. Running Amps Max Ambient Temperature Dimensions H x W x D Net Weight ISC-WF XX-XXX 12,04,4X 8,000 2, / F x 19 x ISC-WF XX-XXX 12,04,4X 8,000 2, / F x 19 x Information Subject to change without notice 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

11 ENCLOSURE AIR CONDITIONERS High Capacity Series 10,000 BTUH - 20,000 BTUH MODELS Designed for Higher Capacity Requirements Indoor/Outdoor NEMA Type 12, 4 and 4X Closed Loop Systems Unique Condensate Management System evaporates moisture from the enclosure thus eliminating drain tubes, buckets, and wet floors in typical applications. Compressor Protection System includes high and low refrigerant cutoffs with fault protection, anti short cycle protection, and compressor run capacitors to increase compressor life and save energy. Highly Efficient with fully insulated and sealed cabinets, and pressure operated blowers that reduce power inrush and saves energy. Digital Temperature Controller with programmable set points, visible error and/or alarm messaging and system status indication. Maintains UL/cUL Type 12, 4 or 4X rating when properly installed on a UL/cUL Type 12, 4 or 4 X rated enclosure. UL/cUL Listed; File No. SA8067 SPECIFICATIONS Part Number BTUH Watts Volts /Hz. Running Amps Max Ambient Temperature Dimensions H x W x D Net Weight ISC-HC XX-XXX 10, / F 48 X15.86 x ISC-HC XX-XXX 10, / F 48 X15.86 x ISC-HC XX-XXX 10, / F 56.6 X15.86 x ISC-HC XX-XXX 12, / F 48 X15.86 x ISC-HC XX-XXX 12, / F 48 X15.86 x ISC-HC XX-XXX 12, / F 56.6 X15.86 x ISC-HC XX-XXX 15, / F 56 x23.3 x ISC-HC XX-XXX 15, / F 65.6 x23.3 x ISC-HC XX-XXX 20, / F 56 x23.3 x ISC-HC XX-XXX 20, / F 65.6 x23.3 x Information Subject to change without notice 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

12 Hazardous Duty Enclosure Air Conditioner 2,000 to 20,000 BTUH Designed for standard and pressured enclosures in Class 1, Div II, Groups B, C, and D in hazardous duty locations. Includes process control systems for chemical, petrochemical, refining, field and offshore drilling operations Indoor/Outdoor NEMA Type 12, 4 and 4X Closed Loop Systems Options: High Ambient Package Corrosive Environment Protection Low Ambient Protection NEMA Type 12, 4 and 4X Available 316 Stainless Steel Construction Oversized Air Filters Anti-Vibration Protection Digital Temperature Controller Programmable set point and temperature operating controls Visible error and/or alarm messaging System status indication Password protection Independent Active Condensate Management System Elimination of condensate Eradicates condensate without corrosive contact with coils Unit Efficiency Pressure operated blower control reduces power inrush and saves energy Fully insulated & sealed cabinet Temperature Control Valve to provide a broad temperature range while maintaining cooling capacity Washable Filter Media Industrial Construction Free standing rigid chassis eases maintenance Durable 16 gauge welded steel construction with a hard wearing powder coated finish for NEMA Type 12 and 4; 304 Stainless Steel for NEMA Type 4X Tamper Resistant Hardware Compressor Protection System High & Low refrigerant cutoffs with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power inrush, save energy and increase compressor life 1 Year Warranty Y, Z and X Purge Systems Information Subject to change without notice 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

13 CONDENSATE MANAGEMENT SYSTEM ISC accomplishes condensate removal from our air conditioners by routing the refrigerant hot gas through a condensate boil off pan. The pan is located ahead of the condenser at the hottest point in the refrigerant system where the gas temperature is 180 to 260 F. Condensate is evaporated and the vapor is discharged through the condenser blower to the environment. Additionally, this condensate evaporation helps to pre-cool the hot gas, making the equipment more efficient. By utilizing this pre-cool method, we lower the overall use of energy needed to power our air conditioners. This condensate boil off pan has enough water storage capacity to dehydrate the air in your equipment enclosure and vent it off without overflow so long as the enclosure remains closed. In the event that the enclosure will remain open, ISC does supply an Emergency Overflow Fitting on all of our units. Use of this Fitting is only for extreme open-door applications and should not be utilized in typical or even heavy applications. Please Contact ISC for instructions on use of this feature Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

14 ENCLOSURE HEAT SYSTEM The ISC Enclosure Heat System is incorporated into the evaporator section of the air conditioner, thereby utilizing the evaporator blower for cooling or heating. Electric heating elements with thermal overloads are available in three ranges to suit most applications. The heater is controlled by our programmable, digital temperature controller. The controller has separate programmable upper and lower control limits for cooling and heating, and a programmable dead band to prevent simultaneous operation of heating and cooling. The temperature set points for cooling and heating can be field adjusted in one-degree increments. The temperature set points can be protected by keypad protection. Specifications: Voltage /230 Watts 500, 1000, 1500, 2500 Capacity, BTUH 1707 / 3413 / 5120 / 8530 Temperature Range Dead band Accuracy Resolution Code Protection -99 to 302 degrees F 1 to 20 degrees F Better than.5% of scale.1 degree 4 digit, customer settable on request 4421 Tradition Trail Plano, Texas or Fax iscinfo@iscsales.com

15 OD Remote Controller Option When having our Programmable Digital Controller on the face of our Enclosure Air Conditioner does not fit your application, ISC offers the OD package. The OD package moves the controller into your enclosure using a 10 cable along with a universal, 16 gauge powder coated steel mounting bracket. As shown below, the Enclosure Air Conditioner would have no hole on the face of the unit creating a secure application of our Enclosure Air Conditioner. This accessory is available on all units including NEMA Type 12, 4 and 4X (304 Stainless Steel) Having a smarter air conditioner is a good choice even when having an exposed Digital Controller may not be the best choice. Pictured is our NEMA Type 4X Air Conditioner with OD Series remote controller option. Information Subject to change without notice 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

16 2 DEEP EXTENDED SURFACE AREA FILTER AND FILTER FRAME Many applications and environments are excessively dusty. If your application is in a flour mill, cement plant or coal processing plant, you understand. These types of environments can create real problems for an air conditioner that by its very design requires a steady flow of reasonably clean air in order to function. The reality is that air conditioners are only as good as their air flow. Because of this, ISC offers our extended surface, 2 deep filter and filter frame assembly. Pictured below, this slide in, slide out filter frame and filter combination will increase the filter capacity 400% over our standard filters. The filter is washable and replaceable. The life expectancy is determined by the environment and the ways in which it is washed and cleaned. This deeper filter frame fits in the standard holes on our NE Series units. Information Subject to change without notice 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

17 CONTROL SYSTEM FOR REDUNDANCY & LEAD/LAG In applications where you require redundant systems to share the cooling requirements, ISC has developed a system that will toggle back and forth between the two units thereby giving them each equal operating time. Additionally, this system provides for the situation where one unit becomes disabled. In this event, the second unit continues to provide the appropriate amount of cooling to your electrical enclosure while the disabled unit would be in alarm mode. This system is intended for 100% redundancy where failure is not an option. This is our alternating, or toggle system. ALTERNATING CONTROL This control method is intended to provide cooling to a common enclosure by two (or more) air conditioners which alternate operation rather than share load. This provides 100% redundancy while balancing the run time on each unit. Two self contained air conditioners with independent dual stage thermostats will be connected with a toggle control so that the units will alternately share the cooling load. In the event of the failure of one unit, the toggle system will be deactivated and the cooling load will be switched to the remaining operational unit. A failure signal will be available to alert the customer that one unit has failed. HIGH LIMIT Each Thermostat has a high set point which is used as a failure alarm. On either high limit, that unit is switched out of the toggle control and cooling will be solely by the alternate air conditioner until the limit is manually reset Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

18 What Makes Our Panel Air Conditioner Unique? AIR FLOW Note the tapered sides of our air conditioner, our design ensures efficient airflow to cool the air conditioner in a tight installation (vs. a box shape air conditioner). We have a slanted top. This forces any water on the top of the unit to drain, thus prevents water pooling. DIGITAL TEMPERATURE CONTROLLER Our digital controller incorporates programmable set point and temperature controls, visible error and or alarm messaging, system status indication and password protection. Remote control is available with our Out Door series. These vandal resistant units provide a 10 cord that connects internally to your enclosure. ACTIVE CONDENSATE ELIMINATION Our design eliminates drain lines and buckets by routing the refrigerant hot gas lines through a condensate boil off pan. This also eliminates the hazards that go along with the puddles and buckets associated with drains. UNIT EFFICIENCY By pre-cooling the refrigerant in the condensate collection pan before it re-enters the refrigeration loop, we lower the energy needed to affect a phase change of the refrigerant. Also, by blowing the vapor laden air through the coil to the outside environment, we equalize the temperature across the coil, lowering energy consumption. This efficiency is evidenced by our lower running amps. Pressure operated blower control reduces power inrush thus consumes less energy. All units incorporate die-cut insulation on all interior sheet metal parts including the shroud (cabinet). Thermal expansion valves are installed in all of our air conditioners instead of capillary tubes. Thermal expansion valves adjust to your operating conditions allowing for much better temperature control, performance and provide lower operating costs. Compressor run capacitors reduce power inrush each time the compressor comes on, saving energy and extending the life of the compressor. HIGH PRESSURE SHUT DOWN Part of our digital controller safety function is to go into alarm if the filter media becomes clogged. Other manufacturers who utilize digital controllers have an alarm interval based on the time between filter cleanings. By using high and low pressure switches, we insure that you are notified before you have a costly failure. CONSTRUCTION Free standing, rigid, 16 gauge, welded steel chassis, minimizes vibration and eases maintenance. PERFORMANCE All units are run tested before they ship, insuring that your unit performs to expectations. WARRANTY Our air conditioners are backed by the industry s best warranty. If troubleshooting determines that your unit has failed due to component failure or workmanship, we will offer to send you replacement parts, a new unit or have the unit field serviced. If a new air conditioner is sent out, a new warranty begins when you receive it. So What Makes Our Panel Air Conditioner Unique? IT IS A SMARTER, MORE DURABLE, MORE EFFICIENT AIR CONDITIONER! 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

19 FILTERED FAN PACKAGES Injection Molded Plastic Powder Coated and Stainless Steel Grills Celebrating 20 Years Of Excellence Efficient, Quiet Ball Bearing Fans 10 Micron Fan Side Filter, 50 Micron Filter on Return All Kits Include Both Fan Side and Exhaust Powder Coated and Stainless Steel Grills All Kits Include Gaskets, Mounting Hardware and Template Available in 304 Stainless Steel Finger Guards on all models Injection Molded Plastic Grills Steel models come standard in Ansi Gray. To order in Black add - BL. 200MFFP available in 304 SS (200SFFP) Steel models come standard with washable filters. 100/200 models come standard in Ansi Gray. To order in Black add - BL. Easy Click and Fit installation Plastic models come standard with washable filters. Powder Coated and Stainless Steel Grill Specifications Model CFM Free Flow Dimensions inches Voltage/Hz Rated Amps Temperature Range ISC100MFFP X / 50/ F to 176F 3300 ISC100MFFP X / F to 176F 3300 ISC100MFFP-24V X VDC F to 176F 3450 ISC200MFFP X / 50/ F to 176F 3300 ISC200SFFP X / 50/ F to 176F 3300 ISC200MFFP X / F to 176F 3300 ISC200SFFP X / F to 176F 3300 ISC200MFFP-24V X VDC F to 167F 3300 ISC200MFFP-24V X VDC F to 167F 3300 ISC500MFFP X / F to 158F 2700 ISC500MFFP X / F to 158F 2700 Plastic Grill Specifications Model CFM Free Flow Dimensions inches Voltage/Hz Rated Amps Temperature Range ISC080PFFP X / 50/ F to 176F 2900 ISC080PFFP X / F to 176F 2900 ISC080PFFP-24V X VDC.23-4F to 176F 3000 ISC100PFFP X / 50/ F to 176F 3300 ISC100PFFP X / F to 176F 3300 ISC100PFFP-24V X VDC F to 176F 3450 ISC200PFFP X / 50/ F to 176F 3300 ISC200PFFP X / F to 176F 3300 ISC200PFFP-24V X VDC F to 167F 3300 ISC390PFFP X / 50/ F to 176F 3300 ISC390PFFP X / F to 176F 3300 ISC390PFFP-24V X VDC F to 176F 3450 ISC500PFFP x / 50/ F to 158F 2700 ISC500PFFP x / F to 158F Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com RPM RPM

20 FILTERED FAN PACKAGES ISC Filtered Fan Packages are designed to vent enclosures where filtered ambient air is acceptable, humidity is not a factor, and your sensitive electronic equipment can operate at a temperature slightly higher than ambient temperature. TO CHOOSE THE RIGHT FAN FOR YOUR APPLICATION FOLLOW THESE SIMPLE DIRECTIONS STEP 1 Determine your enclosure s internal heat load in watts 1 Watt = BTUH INTERNAL LOAD (WATTS) ISC 80 Series ISC 100 Series ISC 200 Series ISC 500 Series ISC 100 P FFP 126 STEP 2 Determine the difference in temperature between the maximum temperature outside the enclosure and the maximum desired temperature inside the enclosure in degrees F (ΔT F ) STEP 3 Looking at the table below: a)on the left vertical scale, find your heat load b)draw a horizontal line to the intersection with the diagonal line representing your ΔT c)from that point extend a vertical line down to the horizontal line to determine the CFM requirement of your enclosure d)continue your vertical line to the colored bar graph below. Bars intersected are represented by the ISC Series Number to the left of the bar. ΔT 60 F ΔT 50 F ΔT 40 F ΔT 30 F VOLUME AIRFLOW (CFM) 81 CFM ΔT 20 F 131 CFM ΔT 10 F 300 CFM ΔT 5 F 700 CFM HOW TO READ MODEL NUMBERS 1. ISC 2. Series number M = Metal, P = Plastic and S = Stainless Steel 4. Filtered Fan Package = 120 Volts 60Hz., 236 = 230 Volts 60Hz. STEP 4 Using the appropriate ISC Fan Series, review the Specifications Table for either metal, plastic or stainless steel fans, and choose the fan voltage that suits your application. ISC FILTERED FAN SIZING GUIDE 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

21 21 3R RAIN SHROUDS 3R Fan Shroud Kits are designed to keep the elements out of your enclosure while maintaining free air movement from your filtered fan packages. Shrouds come 2 to a kit and fit neatly over your openings and fans. 16 Gauge Powder Coated Mild Steel Maintains NEMA Type 3R Kits Include All Mounting Hardware & Template Includes Gaskets on 3 Sides Fit All ISC Filtered Fan Packages ISC100-FFP-3R Use for ISC080 fans ISC500-FFP-3R All shrouds come with a bottom screen for added protection. ISC200-FFP-3R FILTERED FAN PACKAGE Accessories Disposable Fiber Filters Replacement Washable Aluminum/ Stainless Filter Enclosure Open Door Kill Switch OPTIONAL THERMOSTAT Large Setting Range Compact Size Simple to Mount High Switching Performance Normally Open or Normally Closed 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

22 Powder Coated and Stainless Steel Grills ISCMFFP-100 / 131 CFM ISCMFFP-200 / 300 CFM ISCMFFP-500 / 850 CFM 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

23 PLASTIC FILTERED FAN PACKAGES Injection Molded Plastic PFFP-390 / 393 CFM PFFP-080 / 81 CFM PFFP-100 / 131 CFM PFFP-200 / 300 CFM PFFP-500 / 850 CFM 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

24 Vortex Enclosure Cooling Keep Your Electrical Enclosures Cool Clean and Protected 12 Indoor Dust Tight/Drip Tight 4 Outdoor Weatherproof/Washdown 4X NEMA RATINGS Outdoor Weatherproof/Washdown Corrosion Resistant NEMA Type NEMA 12 NEMA 4 NEMA 4X NEMA 4, 4X Vortex Coolers use an internal vortex tube to convert factory compressed air into a low pressure, cold air stream that is distributed throughout the cabinet. The chilled air stream creates a slight positive pressure inside the enclosure to prevent dirt or dust from entering even in the most challenging environments. From small computer cabinets and touch screen control panels to large electrical panel boxes, Vortex Coolers offer efficient and reliable enclosure protection from heat and dirt related shutdowns. All Vortex Coolers systems include a 5-micron Auto- Drain filter and a ducting kit to distribute cold air throughout the enclosure. Thermostatically controlled models also contain a solenoid valve and thermostat, limiting compressed air usage to those times when cooling is required. All Vortex Coolers are UL-listed and maintain NEMA 4, 4X and 12 ratings based on selected model. MODEL NO. W/ THERMOSTAT MODEL NO. W/O THERMOSTAT CAPACITY BTUH 100 PSIG H H SS 737SS SS 787SS SS-35H 787SS-35H SS 7875SS / /70 For assistance in sizing the appropriate model to your requirements, call our Technical Service Department at , or use the Vortex Sizing Sheet on our website:

25 Vortex Enclosure Cooling How Enclosure Coolers Create Cold Air COMPRESSED AIR IN 80 PSIG CONTROL VALVE 20% COLD FRACTION VORTEX GENERATION CHAMBER HOT AIR OUT 250 F / 139 C COLD AIR OUT -40 F/ C Air that rotates around an axis (like a tornado) is called a vortex. A Vortex Tube creates cold air and hot air by forcing compressed air through a generation chamber which spins the air centrifugally along the inner walls of the Tube at a high rate of speed (1,000,000 RPM) toward the control valve. A percentage of the hot, high-speed air is permitted to exit at the control valve. The remainder of the (now slower) air stream is forced to counter flow up through the center of the high-speed air stream, giving up heat, through the center of the generation chamber finally exiting through the opposite end as extremely cold air. Vortex tubes generate temperatures down to 100 F below inlet air temperature. A control valve located in the hot exhaust end can be used to adjust the temperature drop and rise for all Vortex Tubes. The Vortex Cooler system is thermostatically controlled to save energy. The Vortex Cooler system has continuous cooling models available. The Vortex Cooler system cools without Freon or other refrigerants. All Vortex Cooler systems are UL-listed. Vortex Coolers offer cooling capacities from 400 to 5000 BTUH. Vortex Cooling systems provide easy installation, compact size fits in tight spaces. Vortex Cooling systems are quiet and reliable with no moving parts to wear out. Maintains NEMA 4, 4x and 12 ratings. Vortex Cooling systems are very low maintenance. All models include a 5-micron, Auto-Drain air line filter. Vortex Coolers easily mount in tight spaces, with all models ranging only from about 7 to 11 inches tall. MODEL NO ACCESSORIES 208R Pressure Regulator, 3/8 NPT (F), 50 SCFM 208RX Pressure Regulator, 3/4 NPT (F), 200 SCFM 701S-24A Auto-Drain Filter (5 micron water/particulate) 3/8 NPT (F) 25 SCFM 701S-36A Auto-Drain Filter (5 micron water/particulate) 3/8 NPT (F) 50 SCFM 701S-40A Auto-Drain Filter (5 micron water/particulate) 3/8 NPT (F) 150 SCFM 701S-48 Auto-Drain Oil Removal Filter 3/8 NPT (F) 25 SCFM 701S-54 Auto-Drain Oil Removal Filter 1/2 NPT (F) 70 SCFM With no moving parts to wear out or maintain, Vortex Coolers use only compressed air and vortex tube technology to produce quiet, efficient and reliable cabinet cooling. As an added benefit, these coolers create a slight positive pressure inside the enclosure to prevent dirt or dust from entering, even in the most challenging environments Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

26 Vortex A/C Enclosure Cooler Compressed Air Powered Panel Cooling Avoid any downtime, with the most affordable, reliable, and easiest to install thermal protection product available for electrical enclosures! Just as quiet as an air conditioner (about 62 dba), the Vortex A/C noise level is 73% less than other conventional, vortex type cooling systems. When the thermostatically-controlled Vortex A/C is operating, the decibel level is NEW! about the same as normal human conversation! Only 8 in. Tall These Vortex Coolers feature an integral mechanical thermostat to conserve energy and maintain enclosure temperatures within a range of 80 to 90 F. Requiring only a compressed air supply to operate, the UL listed Vortex A/C quickly installs in a 1.5 knockout hole to keep electrical control panels cool, clean and protected. How it Works The Vortex A/C utilizes vortex tube technology to create refrigerated air. With no moving parts, a vortex tube spins compressed air into a vortex with rotational speeds of up to 1,000,000 RPM. The spinning airflow separates into hot and cold airstreams, with cold air temperatures reaching as low as 50 F below the compressed air inlet temperature. The cold air stream passes through an external muffler before it is released into the electrical enclosure. The hot air stream is muffled and exhausted out the back of the unit. The refrigerated air entering the enclosure creates a positive pressure of approximately 2 water column inside the enclosure to keep external dust and dirt from entering the cabinet. As cold air losses its refrigeration to cool the electronics, it forces hot air to rise in the enclosure where it is pushed out through vent openings in the Vortex A/C, exiting out the back of the unit. A highly reliable, built-in mechanical thermostat operates a valve to control airflow and cooling. The new 5000 BTUH Vortex A/C model features dual vortex tube cooling units, each with its own reliable mechanical thermostat to provide two-stage levels of refrigeration. To conserve energy, the first stage offers 2500 BTUH cooling capacity and, if needed, a second stage activates to double the supply of refrigerated air to the enclosure. At a fraction of the size and cost of a refrigerant-based air conditioner, the Vortex A/C provides reliable, below-ambient cooling in environments up to 175 F (79 C). NEMA Type MODEL NO. W/ THERMOSTAT CAPACITY BTUH 100 PSIG NEMA , 4X / /70 MODEL NO ACCESSORIES NEW 701S-48 Auto-Drain Oil Removal Filter 3/8 NPT (F) 25 SCFM E-N 48E Replacement Element for 701S-48A, Compressed Air Oil Removal Filter for 400, 900, and 1500 BTUH Coolers 25 SCFM 701S-54 Auto-Drain Oil Removal Filter 1/2 NPT (F) 70 SCFM E-N 54E E-N 24E E-N 36E E-N 40E 208R Replacement Element for 701S-54A, Compressed Air Oil Removal Filter for 2500 and 5000 BTUH Coolers 70 SCFM Replacement Element for 701S-24A Compressed Air Filter for 400, 900, and 1500 BTUH Coolers, PK of Ten Elements, 25 SCFM Replacement Element for 701S-36A Compressed Air Filter for 2500 BTUH Coolers 50 SCFM Replacement Element for 701S-40A, Compressed Air Filter for 5000 BTUH Coolers 150 SCFM Pressure Regulator, 3/8 NPT(F), 50 SCFM / 1415 SLPM 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

27 Electrical Enclosure Heaters ISC stocks a full line of Compact Enclosure Heaters. Our well trained technical staff is always available to help you with your application. No Voice Mail during normal business hours. PTC Fan Heater Series EHCR027 Compact fan heater in PTC technology Maintains minimum operating temperatures in enclosures Helps to prevent failure of electronic components caused by condensation and corrosion Heating power adjusts to ambient temperature Integrated adjustable thermostat and control light DIN rail mountable UL, VDE and CE Explosion-proof Enclosure Heater Series EH-CREX050 This heater is designed for use in hazardous locations where electronic components shall be protected from condensation and corrosion, sudden temperature drops, and low temperatures. Maintenance-free heater with large convection surface for safe operation. Fan Heater Series EHHVL031 and EHHV031 Small, compact size fan heater Maintains minimum operating temperatures in enclosures Helps to prevent failure of electronic components caused by condensation and corrosion Built in overheat protection Heater can be purchased separately for OEM use Din rail mountable Fan Heater Thermostat ISCKT-011 Compact design Wide adjustment range Available with *F or *C scale Color coded for temperature scale Normally Closed or Normally Open at temperature rise Din rail mounting VDE, UL, CSA 4421 Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

28 PTC Fan Heater ISC CR027 Compact fan heater in PTC technology Maintains minimum operating temperatures in enclosures Helps to prevent failure of electronic components caused by condensation and corrosion Heating power adjusts to ambient temperature Integrated adjustable thermostat and control light DIN rail mountable Technical data CR 027 Max. current Axial Fan 1) Part No. Voltage Power (inrush) (ball bearing) EH400CR VAC 400W (50 Hz) 11A 3 20 cfm (35 m /h) EH550CR VAC 550W (50 Hz) 13A 3 26 cfm (45 m /h) EH550CR VAC 550W (60 Hz) 14A 3 20 cfm (35 m /h) EH650CR VAC 650W (60 Hz) 15A 3 26 cfm (45 m /h) 1) at 68 F (20 C) ambient temperature. Also, power will vary when frequency other than listed is applied. Heating element: PTC-semiconductor/resistor, self-regulating with changing ambient temperature (see graph below) Overheat protection: Built-in temperature limiter in case of fan failure Function control light: LED Housing: Plastic, UL94V-0 For spacing, add 2 clearance Dimensions (H x W x D): 6.5 x 3.94 x 5 (165 x 100 x 128mm) to heat sensitive parts. Connection: 2-pole terminal, AWG 14 max. (2.5 mm²) Mounting: Clip for 35 mm DIN rail (EN 50022) Protection class: II (double insulated) Protection type: IP 20 Agency approvals: UL Thermostat range o 0-60 C o 0-60 C o F o F Weight 2 lbs/0.9 kg 2.4 lbs/1.1 kg 2 lbs/0.9 kg 2.4 lbs/1.1 kg Determining the required heater size: P P A DT = Temperature differential between the desired minimum interior temperature and the Lowest possible external temperature of the enclosure in Kelvin (K), 1.8 F = 1 C = 1K k H V P H=(AxDT x k) - PV = Required heating power for your application in Watts (W) = Heating power generated by existing components (e.g. a transformer) in Watts (W) = Exposed enclosure surface area in square meters (m²) = Heat transmission coefficient of the enclosure material used: Painted steel: 5.5W/m²K Stainless steel: 3.7W/m²K Aluminum: 12W/m²K Polyester/Plastic: 3.5W/m²K For outdoor applications it is recommended to double the heating power. Applications: Electrical & Electronic enclosures Telecommunications systems Automatic teller machines (ATM s) Access & Parking control systems Display panels Personnel booths Ticket dispensers 3.94 (100 mm) 6.3 (160 mm) 4.8 (124 mm) 6.5 (165 mm) 5 (128 mm) Heating Power (W) Heating Power relative to Ambient Temperature C -4 F -10 C 14 F 0 C 32 F 10 C 50 F Ambient Temperature Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application. 20 C 68 F 30 C 86 F 650W heater 550W heaters 400W heater CR /USI

29 Explosion-proof Heater ISC CREX Series Shown: 100W heater mounted on DIN rail Hazardous locations application Maintains minimum operating temperatures in enclosures Helps to prevent failure of electronic components caused by condensation and corrosion Large convection surface DIN rail mountable Technical Data EH-CREX050/100 Operating voltage: Part No. - 50W: - 100W: Explosion protection to EN: Conformity certificate: Protection type: Protection class: Connection cable: Connection PE: Heating element: Heat sink: Mounting: VAC VAC EH-CREX EH-CREX EH-CREX EH-CREX LCIE (Laboratoire Central des Industries Electriques) LCIE 01 ATEX 6073 IP 65 I (grounded) Si HF-JZ 3 x AWG 18 x 3.3 ft (0.75 mm² x 1 m) 4 mm² High performance heating cartridge Extruded aluminum, black anodized Clip for 35 mm DIN rail (EN 50022) Heating power: Ex protection type: Surface temperature T5: Dimensions (H x W x D): Weight: Heating power: Ex protection type: Surface temperature T4: Dimensions (H x W x D): Weight: 50W II 2 G D - EEx d IIC T5 IP6x T100 C 212 F (100 C) Vertical mounting 5.9 x 4.65 x 2.7 (150 x 117 x 69 mm) 2.9 lbs (1.3 kg) 100W II 2 G D - EEx d IIC T4 IP6x T135 C 275 F (135 C) Vertical mounting 7.1 x 4.65 x 2.7 (180 x 117 x 69 mm) 3.3 lbs (1.5 kg) 4.65 (118 mm) DIN clip can alternatively be mounted to other side 2.7 (69 mm) 5.9 / 7.1 (150 / 180 mm) Type: CREx 050W Ne pas ouvrir sous tension. EEx d IIC T5 Attendre 15 min. avant ouverture. AC V / 50W Nicht unter Spannung öffnen. Art. Nr Vor öffnen 15 min. warten. L.C.I.E. 98.E 6110 Do not open while energized. Serial No.: Wait 15 min. before opening. France S.A. Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application. CREx020/03-07/US

30 Compact Fan Heater ISC HVL Series Shown: Fan Heater EH100HVL Watt Small, compact size fan heater Maintains minimum operating temperatures in enclosures Helps to prevent failure of electronic components caused by condensation and corrosion Built-in overheat protection 1) Heater can be purchased separately for OEM use DIN rail mountable Technical Data EHHVL031 / EHHV031 Operating voltage/part nos.: EHHVL031 (complete fan heater): 120 VAC 230 VAC 100W: EH100HVL120 EH100HVL W: EH150HVL120 EH150HVL W: EH200HVL120 EH200HVL W: EH300HVL120 EH300HVL W: EH400HVL120 EH400HVL (715. m m ) 100W/ 150W Heater Mounting hole for DIN clip 0.98 (25 mm) 0.87 (22 mm) 0.16 (4.2 mm) (8 0m m) EHHV031 (heater only): 100W: EH100HV120 EH100HV W: EH150HV120 EH150HV W: EH200HV120 EH200HV W: EH300HV120 EH300HV W: EH400HV120 EH400HV236 Heating element: Resistance type cartridge heater Heat sink: Die-cast aluminum, glass bead finish Required fan size: 100/150W: 80 x 80 x 25 mm (included with HVL 031 heaters) min. air flow: 20 cfm (35 m³/h ) 200/300/400W: 120 x 120 x 25 mm min. air flow: 63 cfm (108 m³/h) Overheat protection: Built-in temperature limiter Air exit temperature: Approx. 113 F (45 C) 2 (50 mm) above heater Wiring compartment: Plastic UL 94V-O Connection (heater): 3-pole terminal, AWG 14 max. (2.5 mm²) Connection (axial fan): 2-pole terminal (L2/N2), AWG 14 max. (2.5 mm²) Mounting: Clip for 35 mm DIN rail (EN 50022) Protection class: I (grounded) Protection type: IP 44 Weight: 100/150W: 0.6 lbs (240 g) without fan 200/300/400W: 1.1 lbs (490 g) without fan Agency approvals: UL (all), VDE (230 VAC only) Determining the required heater size: P H = Required heating power for your application in Watts (W) P = Heating power generated by existing components (e.g. a transformer) in Watts (W) A = Exposed enclosure surface area in square meters (m²) DT = Temperature differential between the desired minimum interior temperature and the Lowest possible external temperature of the enclosure in Kelvin (K), 1.8 F = 1 C = 1K k V P H = (A x DT x k) - PV = Heat transmission coefficient of the enclosure material used: Painted steel: 5.5W/m²K Stainless steel: 3.7W/m²K Aluminum: 12W/m²K Polyester/Plastic: 3.5W/m²K For outdoor applications it is recommended to double the heating power ( mm ) 200W/ 300W/ 400W Heater Label 2.68 (68 mm) Mounting hole for DIN clip 1) Caution: Heater may only be operated with fan! Applications: 2.68 (68 mm) Electrical & Electronic enclosures Telecommunications systems Display panels Personnel booths Automatic teller machines (ATM s) Access & Parking control systems Ticket dispensers (3 2 m m ) 0.16 (4.2 mm) (11 9 mm ) ( 32 mm) 0.71 (18 mm) 0.98 (25 mm) 0.87 (22 mm) Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application. Label Axial fan Axial fan Air flow 0.71 (18 mm) HVL /US

31 Small Thermostat Compact design Wide adjustment range Available with F or C scale Color coded temperature dials DIN rail mountable Thermostat NC (normally closed): Thermostat opens at temperature rise. Comes with a red temperature dial. Thermostat NO (normally open): Thermostat closes at temperature rise. Comes with a blue temperature dial. Technical Data ISCKT 011 Part No. Contact type Scale on housing ISCKT-011-NC normally closed F ISCKT-011-NO normally open F ISCKT-011-NCC normally closed 0-60 C ISCKT-011-NOC normally open 0-60 C 1.3 (33 mm) Sensor element: Maximum tolerance: Switching difference (hysteresis): Service life: Switching capacity (max. load): EMI/EMC compliance: Connections: Mounting: Dimensions (H x W x D): Housing: Weight: Protection type: Operating/storage temperature: Agency approvals: Thermostatic bi-metal ±7.2 F (4K) 12.6 F ± 5.4 F (7 C ± 3K) 100,000 cycles 15A resistive/2a 120 VAC 10A resistive/2a 250 VAC DC 30W EN , EN , EN pole terminal for AWG 14 max. (2.5 mm²) Clip for 35 mm DIN rail (EN 50022) 2.4 x 1.3 x 1.7 (60 x 33 x 43 mm) Plastic, UL94V oz (36 g) IP 20-4 to 176 F (-20 to 80 C) VDE, UL, CSA 1.7 (43 mm) C 2.4 (60 mm) ISCKT-011 (NC) ISCKT-011 (NO) ISCKT-011 (NO) Heater N Filter Fan Signal device L N L N Wiring examples L N KT /US

32 Thermoelectric Air Conditioners 21 Compact, lightweight, thermoelectric cooling systems for electronic and computer enclosures in harsh industrial settings. Unit features a simple, efficient solid state design for reliable performance. "Patented Design" (most models) Solid State Operation - No CFC's, Filters or Compressors Orientation Insensitivity - Unit Can Be Installed in Any Orientation Compact Size and Weight in an Attractive Package Lower Power Consumption than Most Competitive Models Low Noise and Vibration Low Maintenance / High Reliability Corrosion Resistant Stainless Steel Construction Can be Configured for High-Precision Temperature Control Capable of Providing Heating and Cooling From the Same Package Models for Military & Ruggedized Applications Hazardous Location Models Available Innovation in Solid State Cooling Systems Since the introduction of the personal computer, applications for their use in industry has increased dramatically. This trend has moved computers and other sensitive electronic equipment into increasingly hostile environments where the inherent vulnerability of computer electronics have become a major consideration. Costs associated with repairs, downtime and lost data exemplify the need for better protection. Recognizing this need, EIC has emerged as a leader in innovative solutions to electronics cooling requirements. We specialize in the design and manufacture of thermoelectric coolers for a wide range of applications. EIC is dedicated to serving your needs for protecting your investment in computers and sensitive electronic equipment. Theory of Operation The underlying technology that permits construction of these thermoelectric coolers is known as "The Peltier Effect". It utilizes two elements of a semiconductor which is constructed from doped Bismuth Telluride. Upon application of a direct current (DC) power source, these devices generate a cooling action, countered by a generation of heat on the opposite side of the device. Through proper packaging, EIC has harnessed the cooling properties of these devices into modular air conditioners that can dissipate typical loads of 400, and 2500 BTU/HR Tradition Trail Plano, Texas or Fax Web: iscinfo@iscsales.com

33 200 BTU 400 BTU (DC) 400 BTU (AC) 800 BTU 1500 BTU THROUGH AIR CONDITIONER COOLING or OR FLUSH WEIGHT MOUNTING ITEM MODEL NO. BTU HEAT/COOL VOLTAGE NEMA MOUNT (LBS) FOOTPRINT AAC-120-4XT 200 C AC or DC 4X T /4 H x 6 W 2 AAC-120-4XT-F 200 C AC or DC 4X F /4 H x 6 W 3 AAC-120-4XT-HC 200 HC AC or DC 4X T /4 H x 6 W 4 AAC-120-4XT-HCF 200 HC AC or DC 4X F /4 H x 6 W 5 AAC-140-T 400 C DC 12 T /4 H x 7 W 6 AAC-140-T-F 400 C DC 12 F H x 7-1/4 W 7 AAC-140-T-HC 400 HC DC 12 T /4 H x 7 W 8 AAC-140-T-HCF 400 HC DC 12 F H x 7-1/4 W 9 AAC-140-4XT 400 C DC 4X T /4 H x 7 W 10 AAC-140-4XT-F 400 C DC 4X F H x 7-1/4 W 11 AAC-140-4XT-HC 400 HC DC 4X T /4 H x 7 W 12 AAC-140-4XT-HCF 400 HC DC 4X F H x 7-1/4 W 13 AAC-140B-4XT 400 C AC 4X T H x 6 W 14 AAC-140B-4XT-F 400 C AC 4X F /2 H x 6-1/4 W 15 AAC-140B-4XT-HC 400 HC AC 4X T H x 6 W 16 AAC-140B-4XT-HCF 400 HC AC 4X F /2 H x 6-1/4 W 17 AAC-141-T-E 800 C AC 12 T H x 13 W 18 AAC-141-T-EF 800 C AC 12 F H x 15 W 19 AAC-141-4XT-E 800 C AC 4X T H x 13 W 20 AAC-141-4XT-EF 800 C AC 4X F H x 15 W 21 AAC-141-T-E-HC 800 HC AC 12 T H x 13 W 22 AAC-141-T-E-HCF 800 HC AC 12 F H x 15 W 23 AAC-141-4XT-E-HC 800 HC AC 4X T H x 13 W 24 AAC-141-4XT-E-HCF 800 HC AC 4X F H x 15 W 25 AAC-145-T-E 1500 C AC 12 T /4 H x 13 W 26 AAC-145-T-EF 1500 C AC 12 F H x 13 W 27 AAC-145-4XT-E 1500 C AC 4X T /4 H x 13 W 28 AAC-145-4XT-EF 1500 C AC 4X F H x 13 W 29 AAC-145-T-E-HC 1500 HC AC 12 T /4 H x 13 W 30 AAC-145-T-E-HCF 1500 HC AC 12 F H x 13 W 31 AAC-145-4XT-E-HC 1500 HC AC 4X T /4 H x 13 W 32 AAC-145-4XT-E-HCF 1500 HC AC 4X F H x 13 W 1 Standard heating provision ranges between 100 and 400 watts and includes a second, fixed-point thermostat VAC or 220VAC, or 24-28VDC. Additional power configurations available. 3 NEMA 12 for indoor use, dry locations. NEMA 4X for indoor or outdoor use, O.K. for contact with water. 4 Through-mount coolers protrude approx. 3-1/2 into enclosure. Flush-mount units are entirely outside the enclosure. 5 Enclosure cut-out required is slightly smaller than mounting footprint (see website for details). All photos above show the cold side of each air conditioner, which is the portion that faces the interior of the cabinet. ISC Sales, Inc or iscinfo@iscsales.com

34 G1 S2 G3 B5 G6 G4 AIR CONDITIONERS OPTIONS ENCLOSURES S7 G16 Heating Capability Rain Shroud Flush or Through-Mount Condensate Drip Pan Vertical or Horizontal Mounting AC or DC Power Over-temp Alarm (Audible or Visual) Digital Temperature Controller Remote Control Connection Tamper-Resistant Package Hazardous Location (Class 1, Div. 2, Groups A-D) Certification Custom Configurations Locking Latches Wall-Mount Feet View Window Door-Stop Kit Drip Shield Surge Protector Pole-Mount Hardware 19 Rack-Mount Rails Floor Stand Insulation Special Holes & Cut-Outs Full Size (Stand-Up) Models G8 G15 G13 W9 G11 W14 G12 G10 Air Conditioned Enclosures shown represent examples of the many applications we serve. ISC Sales, Inc or

35 No Filters, No Compressor, No Refrigerant, No Maintenance! Long-Life Industrial Grade Fans Model Shown: 800 BTU Certified To UL Standards Adjustable Thermostat 200 to 1500 BTU Sizes Available (2500 BTU Coming Soon) Variety of Power Options Stainless Steel Covers Includes Template, Neoprene Gasket & Stainless Steel Mounting Fasteners Heating Capability Also Available Stainless Steel Mounting Flange is the enemy of your electronics! If you already have an enclosure or panel and you need a highly reliable means to control the internal temperature, select a size and style from the thermoelectric air conditioner chart (to left), or contact us and we will help determine the proper size for your application. Next, arrange for a rectangular cut-out in the side (or front, rear or top) of your enclosure, install the air conditioner, and enjoy worry-free, maintenance-free cooling of your electronics! Full Access Door Opening Sub-panel on Stand-Offs NEMA 4/12 or 4X Enclosures Thermoelectric Air Conditioner Oil-Resistant Gasket Model Shown: 400 BTU Durable Gray Powder Coated Steel or Stainless Steel Extension Frame (not shown) positions air conditioner entirely outside enclosure Condensate Drip Pan Quarter-Turn Latches Print Pocket Grounding Studs Enclosure Model Shown: 24 H x 20 W x 8 D Safely house and COOL your electronics in a variety of applications, both indoors and outdoors! If you require a complete, environmentally-controlled enclosure, select enclosure size, options and an air conditioner, install the integrated equipment package, then forget about it! See charts inside for details. Additional sizes and styles can be found at Our enclosures are suitable for wall-mounting, pole-mounting and floor mounting. Stainless steel units are especially well suited for food processing, chemical plants, water treatment facilities, marine environments, paper mills and more!

36

37 SYSTEM SELECTION SYSTEM SELECTION APPLICATION INFORMATION Type Div. Group Equipment Z 2 X 1 Y 1 EPS Division Quick Start* System & Vent Selection Guide CLASS I APPLICATIONS per NFPA 496 (3000 & 4000 Series also Cenelec and IEC approved) A-D C & D B-D C & D A-D C & D General Purpose General Purpose General Purpose General Purpose Division 2 Division 2 2 Cubic Feet 1001A-LPS-CI 1001A-WPSA-CI 1011-CI 11-LPS-CI 11-WPSA-CI 1001A-WPS-CI 11-WPS-CI 2001A-STD-IB 2001A-STD-CI 1001A-LPS-CI 1001A-WPSA-CI 1011-CI 11-LPS-CI 11-WPSA-CI 1001A-WPS-CI 11-WPS-CI 15 Cubic Feet 1002-LPS-CI 1002-WPSA-CI 1012-CI 1002-WPS-CI 2002-STD-IB 2002-STD-CI 2002-SA-CI 2002-FA-CI 1002-LPS-CI 1002-WPSA-CI 1012-CI 1002-WPS-CI MAXIMUM ENCLOSURE VOLUME 75 Cubic Feet 90 Cubic Feet 200 Cubic Feet 1003-LPS-CI 1003-WPSA-CI 1003-WPS-CI 2003-STD-IB 2003-STD-CI 2003-SA-CI 2003-FA-CI 1003-LPS-CI 1003-WPSA-CI 1003-WPS-CI CLASS II APPLICATIONS (per NFPA 496) APPLICATION INFORMATION Type Div. Group Equipment Z 2 F & G General Purpose X 1 E-G General Purpose Y 1 F & G Division 2 MAXIMUM ENCLOSURE VOLUME 10 Cubic Feet 50 Cubic Feet 250 Cubic Feet 1001A-LPS-CII 1001A-WPS-CII 1011-CII 11-LPS-CII 11-WPS-CII 2001A-STD-CII 1001A-LPS-CII 1001A-WPS-CII 11-LPS-CII 11-WPS-CII 1001B-LPS-CII 1001B-WPS-CII 2001B-STD-CII 1001B-LPS-CII 1001B-WPS-CII 1001C-LPS-CII 1001C-WPS-CII 2001C-STD-CII 1001C-LPS-CII 1001C-WPS-CII 3003-LPS-CI 3003-WPSA-CI 3003-WPS-CI 4003-STD-CI 4003-SA-CI 4003-FA-CI 4003-STD-CI 4003-SA-CI 4003-FA-CI 3003-LPS-CI 3003-WPSA-CI 3003-WPS-CI SYSTEM SELECTION 1004-LPS-CI 1004-WPSA-CI 1004-WPS-CI 2004-STD-IB 2004-STD-CI 2004-SA-CI 2004-FA-CI 1004-LPS-CI 1004-WPSA-CI 1004-WPS-CI 250 Cubic Feet 3004-LPS-CI 3004-WPSA-CI 3004-WPS-CI 4004-STD-CI 4004-SA-CI 4004-FA-CI 4004-STD-CI 4004-SA-CI 4004-FA-CI 3004-LPS-CI 3004-WPSA-CI 3004-WPS-CI 450 Cubic Feet 1005-LPS-CI 1005-WPSA-CI 1005-WPS-CI 2005-STD-IB 2005-STD-CI 2005-SA-CI 2005-FA-CI 1005-LPS-CI 1005-WPSA-CI 1005-WPS-CI EPS Division Bulletin Number QSG-R3.0 11/03 NOTES APPLICATION INFORMATION Division & Group columns indicate rating of surrounding atmosphere. Equipment column indicates rating of equipment to be protected. MAXIMUM ENCLOSURE VOLUME Columns indicate maximum volume of enclosure(s) to be protected, not excluding any consumed volumes. SYSTEM SELECTION Multiple model number listings within single cube indicate range of choices. Type Y & Z System Model Numbers: LPS indicates Less Pressure Switch WPS indicates With Pressure Switch WPSA indicates With Pressure Switch Gr. A-D Type X System Model Numbers: STD indicates Standard SA indicates Semi-Automatic FA indicates Fully Automatic VENT SELECTION System Model #: locate selected system in "Vent Required" or "Vent Optional" column. Vent Model: indicates required/optional vent for selected system. SCFH: Normal SCFH measured with enclosure 3" of water Max SCFH 7"of water. VENT COMPATIBILITY & FLOW RATE SYSTEM MODEL # VENT SCFH VENT REQUIRED* VENT OPTIONAL** MODEL NORMAL MAX 11, 1011, 1001A & 2001A EPV , 1002 & 2002 EPV , 2003 & B & 2001B EPV EPV-3-SM & C & 2001C EPV EPV-4-SM & 2005 EPV *REQUIRED USE INDICATES RAPID EXCHANGE SYSTEMS WHICH REQUIRE A VENT FOR PROPER OPERATION **OPTIONAL USE INDICATES SYSTEMS WHICH REQUIRE A VENT OR REDUNDANT SUPPLY REGULATOR BEBCO EPS Pepperl+Fuchs Inc Enterprise Parkway Twinsburg, Ohio Telephone (330) FAX (330) sales@us.pepperl-fuchs.com

38 For 20 years ISC has offered thermal management products for electrical enclosures designed to meet the most exacting specifications. We stock many of the items that OEM's integrate into their projects including Air Conditioners, Vortex Coolers, Filtered Fan Packages, Heat Exchangers, Thermoelectric Coolers, Enclosures, and many Specialty Products. What sets us apart from other suppliers is our commitment to customers. During normal business hours you will always speak with a well trained technical advisor that understands your application. We stock a large selection of standard items for quick ship, and price them competitively. Our custom products have the best lead times available.

39

40 2X O.219 SECURE BARREL BOLT OUTSIDE ENCLOSURE WITH 2X SCREWS FROM INSIDE ENCLOSURE 6X O.219 SECURE WITH 6X HEX HEAD BOLTS REVISION HISTORY REV DESCRIPTION DATE APPROVED A A A RIGHT A LOCATE DESIRED ELEVATION LOCATE CUTOUTS AND HOLES APPLY GASKET TO MOUNTING FACE OF UNIT. FASTEN 2 BARREL BOLTS OUTSIDE ENCLOSURE AND HANG AIR CONDITIONER BY THE AIR CONDITIONER'S KEYHOLE SLOTS AT THE TOP TOP.15 A A A OUTLINE AND INSTALLATION CUTOUT TEMPLATE BEFORE USING VERIFY ACCURACY A BOTTOM FASTEN AIR CONDITIONER FROM INSIDE ENCLOSURE WITH 6 X HEX HEAD BOLTS (1/2" LONG SUPPLIED FOR UP TO 12 GA. ENCLOSURES) LEFT OUTLINE AND INSTALLATION TEMPLATE Hole Table Hole Size Count Actual scale may vary from printer to printer. Installer is responsible for accuracy and placement. A Ø DRAWN CHECKED ENG APPR MGR APPR NAME dakins DATE 03/13/08 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES ANGLES ±1 or 1 PL ±0.5 2 PL ± PL ±0.010 TITLE SIZE D INSTALLATION TEMPLATE NE010 DWG NO NE010 CUTOUT REV FILE NAME: isc_ne_010_cutout.dft SCALE: WEIGHT: SHEET 1 OF 1

41 PLACE THE TEMPLATE, CUT AND DRILL OPENINGS AND HOLES THE NEXT SHEETS STEP THROUGH MACHINE PLACEMENT INSTALL BARREL BOLTS OUTSIDE WITH SCREWS FROM INSIDE THIS INSTALLATION GUIDE APPLIES TO NE010, NE015, NE020, NE030, NE040, NE050, NE060 AND NE080 WHICH ARE SUPPLIED WITH HANGER BOLTS FOR ONE-MAN INSTALLATION. NE SERIES INSTALLATION Capacities Indicated NE BTU/H NE BTU/H NE BTU/H DWG NO SHEET 1 OF 3 NE INSTALLATION GUIDE FILE NAME: NE Installation, NE040 example.dft

42 THIS SHOWS NE020, NE030 AND NE040 TILTED ABOUT 2 INCHES, WHICH IS ALSO PERMISSIBLE FOR NE050, NE060 AND NE080. NE010 AND NE015 SHOULD BE TILTED ONLY ABOUT 1.00 INCH. GASKET WILL COMPRESS SLIGHTLY WITH UNIT TILTED AND BRACED AGAINST ENCLOSURE. A A HEAD OF BARREL BOLTS PROTRUDES THROUGH THE AIR CONDITIONER CHASSIS'S KEYHOLE SLOTS AND GRAB THE AIR CONDITIONER AS IT SLIDES DOWN. 2 SECTION A-A NE SERIES INSTALLATION Capacities Indicated NE BTU/H NE BTU/H NE BTU/H DWG NO SHEET 2 OF 3 NE INSTALLATION GUIDE FILE NAME: NE Installation, NE040 example.dft

43 VIEW FROM INSIDE ENCLOSURE - ENCLOSURE IS SHOWN SEMI-TRANSPARENT ALIGN KEYHOLE SLOTS IN AIR CONDITIONER WITH BARREL BOLTS. SCREWS INSIDE SECURE BARREL BOLTS OUTSIDE AIR CONDITIONER MAY BE NEARLY FLAT OR SLIGHTLY TILTED TO ENGAGE BARREL BOTS. AIR CONDITIONER MAY THEN BE GUIDED DOWN ONTO BARREL BOLTS AND IS READY FOR PERMANENTLY BOLTING TO ENCLOSURE. NE SERIES INSTALLATION Capacities Indicated NE BTU/H NE BTU/H NE BTU/H DWG NO SHEET 3 OF 3 NE INSTALLATION GUIDE FILE NAME: NE Installation, NE040 example.dft

CR 027 PTC Fan Heater W

CR 027 PTC Fan Heater W CR 027 PTC Fan Heater 400-650 W Compact fan heater Heating power adjusts to ambient temperature Integrated adjustable thermostat Built-in overheat protection DI rail mountable The semiconductor CR 027

More information

Enclosure Heaters and Fan Heaters

Enclosure Heaters and Fan Heaters Enclosure Heaters and Fan Heaters ISC carries innovative products for heating, cooling, temperature and humidity control of electronic enclosures. Our products are renowned for their reliability, long

More information

Thermal Management INDEX. Management. Thermal TM-1

Thermal Management INDEX. Management. Thermal TM-1 Heat builds up rapidly in enclosed environments, compromising the performance and life span of equipment. Like insurance for your electronics, effective thermal management maximizes the efficiency and

More information

ENCLOSURE AIR CONDITIONERS

ENCLOSURE AIR CONDITIONERS ENCLOSURE IR CONDITIONERS Compact Series 2,000 BTUH Celebrating 20 Years of Excellence Engineered & manufactured to endure the most difficult of environments and applications. ISC air conditioners will

More information

Cabinet Cooler Systems

Cabinet Cooler Systems Cooler Systems Cooler Systems Stop electronic control downtime due to heat, dirt, and moisture! maintain NEMA 4, 4X, and 12 integrity. All are and compliant! What is an EXAIR Cooler System? A low cost,

More information

Thermal Management Products & Accessories for Enclosures

Thermal Management Products & Accessories for Enclosures Thermal Management Products & Accessories for Enclosures Photo: STEGO International Headquarters in Germany STEGO, Inc. 1395 S. Marietta Parkway Building 800 Marietta, GA 30067 Tel: (770) 984-0858 Fax:

More information

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ USA Phone: web:

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ USA Phone: web: Humidity and heat are real problems for us. Hoffman is the only company we ve found that offers a full line of environmental management options and has the expertise to apply them. Thermal Management The

More information

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE 763.576.3200 SPEC-00051 O763.422.2211 THERMAL MANAGEMENT ACCESSORIES ENCLOSURE HEATERS Accessories Enclosure Heaters TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP

More information

TOUCH-SAFE HEATERS INDUSTRY STANDARDS

TOUCH-SAFE HEATERS INDUSTRY STANDARDS 763.576.3200 SPEC-00051 L763.422.2211 ACCESSORIES ENCLOSURE HEATERS ACCESSORIES ENCLOSURE HEATERS TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP 20 CE APPLICATION

More information

Application. Specifications. Finish

Application. Specifications. Finish Spec-00051 I( McLean Electronics Cooling Thermal Accessories McLean Electronics Cooling: Thermal Accessories Touch-Safe Heaters Industry Standards curus Component Recognized; File No. E150057 IP 20 CE

More information

RACK-MOUNT Air Conditioners

RACK-MOUNT Air Conditioners RACK-MOUNT Air Conditioners 2000-10000 BTU/HR. 586-2930 WATTS RCR11 LB16 LB14 FEATURES RCR11 is part of the ProAir Series which combines state-of-the-art design with pleasing aesthetics. This rack mount

More information

Performance Data. curus Component Recognized; File No. E IP 20

Performance Data. curus Component Recognized; File No. E IP 20 TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP 20 CE APPLICATION Protect electrical, mechanical equipment from low temperatures, condensation, and corrosion with

More information

Keep Electrical Enclosures Cool, Clean and Protected

Keep Electrical Enclosures Cool, Clean and Protected Enclosure Coolers Keep Electrical Enclosures Cool, Clean and Protected Have your production lines or equipment ever shutdown from overheated electrical enclosures? It s a common problem, and one that can

More information

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page How to Select and Size Enclosure Thermal Management Systems Follow the steps detailed in this white paper for optimal

More information

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOG 2014 2 PERFECT THERMAL MANAGEMENT PRODUCT CATALOG - STEGO, Inc. STEGO, Inc. PRODUCT CATALOG - STEGO, Inc. PERFECT THERMAL MANAGEMENT 3 INNOVATION Thermal

More information

ENCLOSURE COOLING. Glossary

ENCLOSURE COOLING. Glossary ENCLOSURE COOLING Glossary Contents INTRODUCTION... 3 TYPES OF COOLING EQUIPMENT... 4 COOLING EQUIPMENT COMPONENTS... 5 ESSENTIAL COOLING S... 8 COOLING EQUIPMENT ACCESSORIES... 13 EQUIPMENT THAT NEEDS

More information

Featured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products

Featured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products : CHAPTER Thermal Management Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P. 1152 Featured Products in this Chapter Outdoor Air Conditioners T43, T50 and T53 Series 6,680-20,000 BTU/Hr.

More information

SEALED ENCLOSURE COOLING

SEALED ENCLOSURE COOLING ADVANCED COOLING TECHNOLOGIES The Thermal Management Experts www.1-act.com SEALED ENCLOSURE COOLING ABOVE-AMBIENT AND SUB-AMBIENT COOLING PRODUCTS TABLE OF CONTENTS HEAT SINK COOLER (ACT-HSC) HEAT EXCHANGER

More information

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue Product Catalogue Thermal Management Products & Accessories from STEGO successfully used worldwide for control panels and enclosures for traffic control and monitoring systems in the transport industry

More information

CHAPTER12. Thermal Management. Featured Products in this Chapter. Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P.

CHAPTER12. Thermal Management. Featured Products in this Chapter. Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P. PH FX (763) 422-2600 422-2211 : CHAPTER12 Thermal Management Featured Products in this Chapter Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P. 1156 Outdoor Air Conditioners T43, T50

More information

Vortex Enclosure Coolers A/C ATEX

Vortex Enclosure Coolers A/C ATEX CONTENTS 1 Vortex Enclosure Coolers A/C ATEX Contents 1 Vortex Enclosure Coolers A/C ATEX 2 1.1 Overview........................................ 2 1.2 Features........................................ 2

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

NOREN Products. Compact Cabinet Coolers

NOREN Products. Compact Cabinet Coolers NOREN Products Back to INTRODUCTION Inc. 3 Noren Products Inc. produces a broad range of heat transfer devices incorporating heat pipes. Several of the company's products are widely recognized by their

More information

KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET

KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET TYPE 4 INDOOR OUTDOOR TYPE 4 480 VOLT INDOOR OUTDOOR TYPE 12, 3R AND 4 (4X OPTIONAL) SLIMKOOL Guardian/ GuardianX Series 4 Rating Maintained ( 4X Rating

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

AIR TO AIR HEAT EXCHANGERS

AIR TO AIR HEAT EXCHANGERS AIR TO AIR HEAT EXCHANGERS HEAT PIPE TECHNOLOGY CLOSED LOOP DESIGN AVAILABLE IN 120, 230, 24VDC & 48VDC NEMA TYPE 12, 4 AND 4X UL LISTED FOR STANDARD AND HAZARDOUS LOCATIONS A2A SERIES AIR TO AIR HEAT

More information

FIGURE 1 Forced Convection Method. Filter & Grille Required. Ambient Air. Filter & Grille Required

FIGURE 1 Forced Convection Method. Filter & Grille Required. Ambient Air. Filter & Grille Required K GENERAL INFORMATION Wiegmann has always recognized that our customers in the electrical and electronic marketplace need reliable, high quality enclosures and environmental control products to meet their

More information

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners 763.576.32 Spec-733 C763.422.2211 Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners T-SERIES Compact Outdoor T15 8 BTU/Hr. 234 Watts T2 2 BTU/Hr. 586 Watts INDUSTRY STANDARDS UL/cUL Listed;

More information

Stego accessories for cabinets

Stego accessories for cabinets www.klinkmann.com Stego accessories for cabinets page Small semiconductor Heater RC 016 2 Touch-Safe Small Heater CSK 060 3 Semiconductor Heater HG 140 4 Hazardous area Heater CREx 020 5 Touch-Safe Heater

More information

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C: McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C: 1355-4 Page 2 / Catalog 1355-4 (Rev. 5/99) The McQuay Suite II Incremental packaged terminal air conditioners

More information

Positive Temperature Coefficient (PTC2) Heater Manual

Positive Temperature Coefficient (PTC2) Heater Manual 2ND GENERATION Positive Temperature Coefficient (PTC2) Heater Manual PTC2-MANUAL 1.5 Read and understand this manual prior to operating or servicing the products. PTC2 Heater Systems are manufactured and

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Product Management, Rev 3 December 2009

Product Management, Rev 3 December 2009 Climate Control Product Overview Product Management, Rev 3 December 2009 Why climate control? Common Causes of Electrical/Electronic Equipment Failure Name/Department of author Vibration 21% Humidity 16%

More information

T-Series Air Conditioner T20 Model

T-Series Air Conditioner T20 Model INSTRUCTION MANUAL T-Series Air Conditioner T20 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

Quality Enclosures. Service Excellence.

Quality Enclosures. Service Excellence. Cooling Products General Information...5 General Selection Considerations...5 Sizing an Air Conditioner...6 General Specifications for Air Conditioners...7 Side Mounting DTS Series Air Conditioners 1200

More information

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C) The Norseman Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions. Norseman unit heaters are available

More information

ACT-HSC Series Heat Sink Coolers Sealed Enclosure Cooling Installation Guide

ACT-HSC Series Heat Sink Coolers Sealed Enclosure Cooling Installation Guide ACT-HSC Series Heat Sink Coolers Sealed Enclosure Cooling Installation Guide SA44609 ACT-HSC-22 ACT-HSC-45 ACT-HSC-68 Sealed Enclosure Coolers Keep The Inside of your Enclosure Free of Dirt & Debris NEMA

More information

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100 HTD High Temperature Non-Cycling Refrigerated Compressed Air Dryers Operation & Maintenance Manual MODELS HTD 21 thru HTD 100 - TABLE OF CONTENTS - 1.0 GENERAL 2 1.1 How to use this manual 1.2 Symbols

More information

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N GENESIS Air Conditioners All Models INSTRUCTION MANUAL Rev. K P/N 89104462 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N T-SERIES Air Conditioner T20 Model INSTRUCTION MANUAL Rev. C P/N 89114993 TABLE OF CONTENTS Warranty and Return Policy... 2 IMPORTANT NOTICE... 2 RECEIVING THE AIR CONDITIONER... 3 HANDLING AND TESTING

More information

T-Series Air Conditioner T53 Model

T-Series Air Conditioner T53 Model INSTRUCTION MANUAL T-Series Air Conditioner T53 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package

More information

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation Filtration Balston Membrane Nitrogen Generators Compressed Air Dryers 157 Parker Hannifin Corporation Membrane Air Dryers Provide Clean, Dry Compressed Air Offer a reliable, efficient, and economical alternative

More information

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N SPECTRACOOL Air Conditioner N21 Model INSTRUCTION MANUAL Rev. G P/N 89115088 TABLE OF CONTENTS WARRANTY AND RETURN POLICY...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N PROAIR Air Conditioner CR23 Model INSTRUCTION MANUAL Rev. D P/N 89112522 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater Toll-Free: 1-800-462-4983 Hazardous Location Fan Forced Unit Heater 3-25KW for Class I, Group C & D, Division 1 & 2 and Class II, Groups E, F & G, Divisions 1 & 2. Designed for rugged industrial applications

More information

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N PROAIR Air Conditioner CR29 Model INSTRUCTION MANUAL Rev. I P/N 89104461 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes Spec-75 A( McLean Electronics Cooling Sealed Enclosure Cooling McLean Electronics Cooling: Sealed Enclosure Cooling SPECTRACOOL Compact Indoor N17 115/23 Volt 1 BTU/Hr. Watt N17 46 Volt 18 BTU/Hr. 527

More information

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection Series PIN New Construction or Renovation Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction or Renovation The Adirondack-Aire PIN Series zerozone chassis provides environment

More information

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N T-SERIES Air Conditioner T29 Model INSTRUCTION MANUAL Rev. I P/N 89104464 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE

More information

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T15 Model INSTRUCTION MANUAL T-Series Air Conditioner T15 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A A e r o S y s I n c o r p o r a t e d Ceiling Mounted Systems CeilMate TM Series 3 and 4 tons of cooling capacity Air Handler with Remote Condensing Unit Air Handler designed for R-410A AeroSys, Inc. 929

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

GENESIS Indoor Air Conditioners

GENESIS Indoor Air Conditioners Product Overview : Indoor Air Conditioners M28 Model M52 460 Volt 3-Phase Model M17 Model 68 68 Product Overview : The specifier s choice for cooling industrial process controls Indoor Air Conditioners

More information

VERTICAL FAN COIL UNITS

VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

LUH HORIZONTAL FAN-FORCED UNIT HEATER

LUH HORIZONTAL FAN-FORCED UNIT HEATER LUH HORIZONTAL FAN-FORCED UNIT HEATER VERSATILE, FAN-FORCED HEATING FOR COMMERCIAL AND INDUSTRIAL COMFORT HEAT APPLICATIONS Horizontal airflow Wall or ceiling mounting Self-contained Totally enclosed fan

More information

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N T-SERIES Air Conditioner T43 Model INSTRUCTION MANUAL Rev. I P/N 10-1008-145 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING

More information

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers) WLCG/WLHG R-410A High-Efficiency Ductless Split System High-Wall Air Handlers Straight cool / Heat pump nominal capacities WLHG09 WLHG12 WLHG24 Units 9,000 12,000 18,000-23,800 Btuh 2.6 3.5 5.3-7.0 kw

More information

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes Spec-728 CPH FX ( McLean Electronics Cooling Sealed Enclosure Cooling McLean Electronics Cooling: Sealed Enclosure Cooling SPECTRACOOL Indoor/Outdoor G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt

More information

OPERATING & MAINTENANCE MANUAL HORIZONTAL WATER SOURCE HEAT PUMP. World class comfort.

OPERATING & MAINTENANCE MANUAL HORIZONTAL WATER SOURCE HEAT PUMP. World class comfort. OPERATING & MAINTENANCE MANUAL HORIZONTAL WATER SOURCE HEAT PUMP World class comfort. welcome Congratulations on your selection of Ice Air Water Source Heat Pumps (WSHPs) for your comfort conditioning

More information

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB Explosion-Proof Forced Air Unit Heater - XGB The XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions.

More information

SPECTRACOOL Indoor & Outdoor Air Conditioners

SPECTRACOOL Indoor & Outdoor Air Conditioners PH FX ( Product Overview : SPECTRACOOL Indoor & Outdoor Air Conditioners G52 Indoor Model G57 Outdoor Model G28 Indoor Model 18 18 Product Overview : Makes electronics cooling easier, so you can go about

More information

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Specification General The Powerex Laboratory Open Scroll Air Compressor System is designed to provide clean, dry air for applications

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through tons, up to 7,800 BTUH Heating The SPXB-HW Series "Suite 0" is a compact, throughthe-wall single package vertical HVAC

More information

FX5 Series Explosion-Proof Electric Air Heaters

FX5 Series Explosion-Proof Electric Air Heaters FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA L14 ENVIRONMENTAL CONTROL Ever since components have been made to control electrotechnical tasks, heat loss has been a subject to take into consideration. Sometimes more sometimes less. Major problems

More information

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL Table of Contents Introduction 3 Incoming Inspection 3 General Safety & Warnings 3 Technical Specifications 4 Installation and Operation Instructions

More information

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB Explosion-Proof Forced Air Unit Heater - XGB The XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions.

More information

Intelligent Electronic Enclosure Thermal Management Systems

Intelligent Electronic Enclosure Thermal Management Systems Intelligent Electronic Enclosure Thermal Management Systems IQ27000V OPERATION AND INSTALLATION MANUAL *** IMPORTANT *** PLEASE READ this manual and follow the instructions for safe and satisfactory installation

More information

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 25,240* Design CFM: 800 Seasonal

More information

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons) ENGINEERING DATA HEAT PUMP OUTDOOR UNITS HP40 50HZ Capacity 6.2 to 16.3 (21 200 to 55 500 Btuh) Heating Capacity 6.4 to 16.1 (21 800 to 55 500 Btuh) Bulletin No. 490088 October 2004 Supersedes August 1999

More information

Technical Specification VFD

Technical Specification VFD Technical Specification - 3-6 VFD Pilot valve enclosures suitable for use in hazardous certified environments. These enclosures are designed and tested to contain both flame and the ignition of dust and

More information

KUH. Horizontal Unit Heater. Applications. Description

KUH. Horizontal Unit Heater. Applications. Description KUH KUH PDS Horizontal Unit Heater 2.6 kw to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

TOP 29 QUESTIONS PROSPECTIVE ENCLOSURE COOLING THERMAL EDGE CUSTOMERS ASKED BY Thermal Edge, Inc

TOP 29 QUESTIONS PROSPECTIVE ENCLOSURE COOLING THERMAL EDGE CUSTOMERS ASKED BY Thermal Edge, Inc TOP 29 ENCLOSURE COOLING QUESTIONS ASKED BY PROSPECTIVE THERMAL EDGE CUSTOMERS 2015 Thermal Edge, Inc. 888.580.0202 About the Authors LISA BAKER Lisa Baker is the Inside Sales Manager. When you need help

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

SPECTRACOOL INDOOR/OUTDOOR

SPECTRACOOL INDOOR/OUTDOOR SPEC-728 E SEALED ENCLOSURE AIR CONDITIONERS SEALED ENCLOSURE AIR CONDITIONERS SPECTRACOOL INDOOR/OUTDOOR G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt G28 4/6 BTU/Hr. 1172/ Watt Clean AirFlow Ambient

More information

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006 Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba

More information

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4 TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4 ENVIRONMENTAL ASPECTS.. 6 SPECIAL REQUIREMENTS.. 8 MANUFACTURER CONSIDERATIONS.. 8 SELECTING AN ENCLOSURE AIR CONDITIONER.... 9 2 Although the selection

More information

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14 Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14 GENERAL The Powerex Laboratory Open Scroll Air Compressor System is designed to provide clean, dry air for applications

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

CNC Series Refrigerated Air Dryer CFM

CNC Series Refrigerated Air Dryer CFM CNC Series Refrigerated Air Dryer 10 3000 CFM NEW Engineered to Save CNC Value CompAir leads the way in providing value to our customers We looked beyond the typical refrigerated air dryer and designed

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

Centro-Matic Automated Lubrication Systems System Controls

Centro-Matic Automated Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

Genie Heated Regulator Installation & Operation Instructions

Genie Heated Regulator Installation & Operation Instructions Genie Heated Regulator Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales, LA 70737

More information

2 shp 13 lc 1 36 t - 1 a

2 shp 13 lc 1 36 t - 1 a HEAT PUMPs 2SHP3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20645 July 203 Supersedes June 202 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 shp 3 lc 36 t - a Refrigerant Type 2 =

More information

AC-046 Peltier-Thermoelectric Air Cooler

AC-046 Peltier-Thermoelectric Air Cooler AC-046 Peltier-Thermoelectric Air Cooler Heats as well as cools (when used with heat & cool / bipolar controller) great for refrigeration of small containers and small heat loads. High density extruded

More information

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International 12,000 BTU Portable Air Conditioner Operating PE3-12R-03 Instructions 3092402 Model No. PE3-12R-03 2010 Soleus Air International Thank you for choosing a Soleus Air PE3-12R-03 Portable Air Conditioner.

More information

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N PROAIR Air Conditioner CR43 Model INSTRUCTION MANUAL Rev. H P/N 10-1008-130 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

LIFTAIRE II ELEVATOR AIR CONDITIONER

LIFTAIRE II ELEVATOR AIR CONDITIONER LIFTAIRE II ELEVATOR AIR CONDITIONER THE LATEST IN A SERIES OF AIR CONDITIONERS/HEATERS DESIGNED SPECIFICALLY FOR USE IN ELEVATORS. Airxcel, the maker of the #1 brand of air conditioners in the recreational

More information

VA G 052 S

VA G 052 S 763.576.3200 SPEC-00746 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners V-SERIES COMPACT AIR CONDITIONERS VA06 Indoor Model 400 and 600 Watts INDUSTRY

More information

SPXA / SPXA-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

SPXA / SPXA-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat NOW WITH VA TRANSFORMER! SPXA / SPXA-HP Series Single Package Vertical Unit Straight Cool and Heat Pump / through tons, up to 1 kw Electric Heat The SPXA Series "Suite " is a compact, through-the-wall

More information