General Product Catalogue

Size: px
Start display at page:

Download "General Product Catalogue"

Transcription

1 General Product Catalogue Phoenix Dosimetry Ltd Telephone: +44 (0) Unit 8, Lakeside Business Park, Swan Lane, Sandhurst, Berkshire GU47 9DN

2 Dosimetry Solutions from Phoenix Dosimetry Ltd Repairs for Mini Instruments and legacy NE Equipment Phoenix Dosimetry Ltd are specialists in Dosimetry Peripherals and Harshaw TLD systems. We also offer Service contracts, repairs and training on TLD Readers and peripheral Dosimetry equipment. PEP ( Electron : Photon ) Phantom NPL 2611 Secondary Standard Chamber Harshaw TLD Readers Original Farmer 0.6cc Ionisation Chambers NE2571 and NE2581. Repairs and parts also available Dosimetry Extension Cables and Patch Panels Secondary Standard Intercomparison Phantom NE2566 Vac Fix Immobilisation Cushions from Par Scientific Barts Solid Water and Bolus Aegis ED-3 Real time Extremity Monitor PAR ACD-4 Block Cutter

3 General Product Contents: Ionisation Chambers - Pages 1-5 NE2571/NE2581 Original Farmer Chambers, NPL-2611 Secondary Standard Chamber, Bespoke Detector Holders, Chamber Accessories / Spares Extension Cables and Patch Panels Pages 6-8 Customised Dosimetry Cables, Bespoke and off the shelf Patch Panels Dosimetry Phantoms Pages 9-10 PEP versatile 1 D small Water Phantom, NE-2566A Inter-Comparison Phantom for Farmer and secondary standard, NE-2528/3 Water Phantom Solid Water and Bolus Material Pages Solid Water Slabs for Photons/Electrons with optional customised cut-outs, Bolus material Vaseline based and Brass PAR Scientific Mould Room Equipment Page 13 Automatic Block Cutter, VacFix Bags, VacFix Pump, Melting Pots, Alloy Quality Assurance Tools by Eckert & Ziegler Page 14 Isocentric Beam Checkers, PermaDoc Phantom, Reinstein EZ Cube Phantom ED3 Extremity Dosemeter Page 15 John Caunt ED-3 Aegis - Real Time Extremity Dosemeter TLD Readers, Materials and Accessories Pages Harshaw TLD Readers for Medical, Environmental, Experimental and Personal Monitoring applications (using passive dose measurements) Radiation Monitors Pages RadEye and Portable Radiation / Contamination Monitors for all types of Radiation Service/Calibration Page 22-24

4 NE2571 Farmer 0.6cc Ionisation Chamber The Farmer NE2571A cylindrical ionisation chamber is the original 0.6 cm3 chamber designed by Professor F. T. Farmer. It is constructed from a thin-walled, high purity graphite thimble and aluminium electrode, with a detachable build-up cap which also protects the thimble. Careful guarding of the signal conductors and cable has ensured low postirradiation leakage. The NE2571A is used throughout the world for the measurement of photon and electron beam dosimetry. It is also possible to purchase the graphite thimble replacements and water proof sheaths (please refer to the sales office). NE2571A is delivered as standard with a detachable build-up cap, 10 metre cable, Triax TNC plug; and carry case. Variations to this are available upon request. Specification Sensitive Volume 0.69cm 3 Sensitivity for X-rays of 1mm Cu HVL Energy range for X and gamma radiation: (a) Without build-up cap: (measures exposure) 4.6 R.nC R.min -1.nA Gy.µC Gy.min -1.nA -1 50kV to 300kV (b) With build-up cap: (measures exposure) 0.3MV to 35MV Physical Characteristics Sensitive Volume: Sensitive Length: Thimble materials: Inner diameter: Wall thickness: 0.69cm mm 99.99% graphite 6.3mm 0.36mm (c ) In suitable phantom (measures absorbed dose to water) Energy range for electrons: In suitable phantom (measures absorbed dose to water) 2MV to 35MV 5MeV to 35MeV Inner electrode: Length: Outer diameter: Build-up cap: Wall thickness: Outside diameter Density: Stem: Outside diameter Length of connecting cable: 99.99% aluminium 20.6mm 1.0mm Delrin CH mm 15.1mm 1.425gm cm mm 10mm Leakage current: Typical: Maximum: Maximum exposure rate (approx) or 99% collection efficiency: Polarising potential 250V 5 x A 1.5 x A 4 kr.min -1, continuous 25 mr/pulse, pulsed 40 Gy.min -1, continuous 0.25 mgy/pulse, pulsed Polarising potential 400V 10 kr.min -1, continuous 40mR/Pulse, pulsed 100 Gy.min -1, continuous 0.4 mgy/pulse, pulsed 1

5 NE2581 Robust Farmer 0.6cc Ionisation Chamber NE-2566A Secondary Standard Intercomparison Phantom. The 0.6 cm3 NE2581A is a robust Shonka Plastic version of the Graphite based NE2571A with similar applications but using a tissue equivalent inner electrode and thimble. This is particularly suitable for routine output checks of X-ray, 60Co and Linacs. Specification Sensitive Volume 0.56cm 3 Associated and Peripheral equipment includes: Chamber repair kit NPL2611 Secondary Standard Chamber NE2566A Intercomparison Phantom (see picture) NE2528/3 Small Water Phantom for NE2571 PEP small Photon Electron Water Phantom Dosimetry Extension Cables Solid Water Sensitivity for X-rays of 1mm Cu HVL Energy range for X and gamma radiation: (a) Without build-up cap: (measures exposure) 5.9 R.nC R.min -1.nA Gy.µC Gy.min -1.nA kV to 300kV The NE2581A is delivered as standard with a detachable build-up cap, 10 metre cable, TNC plug; carry case variations available upon request. Physical Characteristics Sensitive Volume: Sensitive Length: 0.56cm mm (b) With build-up cap: (measures exposure) (c ) In suitable phantom (measures absorbed dose to water) 0.3MV to 2MV 2MV to 35MV Thimble materials: Inner diameter: Wall thickness: Inner electrode: Length: Outer diameter: Build-up cap: Wall thickness: Outside diameter Density: Stem: Outside diameter Length of connecting cable: Shonka A mm 0.36mm Shonka A mm 3.0mm Lucentine CH 5.61mm 18.6mm 1.06gm cm mm 8.62mm Energy range for electrons: In suitable phantom (measures absorbed dose to water) Leakage current: Typical: Maximum: Maximum exposure rate (approx) or 99% collection efficiency: Polarising potential 250V 5MeV to 35MeV 5 x A 1.5 x A 50 kr.min -1, continuous 100 mr/pulse, pulsed 50 Gy.min -1, continuous 1 mgy/pulse, pulsed Polarising potential 400V 130 kr.min -1, continuous 150mR/Pulse, pulsed 1.3 kgy.min -1, continuous 1.5 mgy/pulse, pulsed 2

6 NPL-2611 Secondary Standard Therapy Dosimetry Chamber The 2611A chamber consists of a thin walled high purity graphite thimble, amber insulators and a hollow pure aluminium electrode supported by a thin walled aluminium stem. The stem terminates in a robust cable entry, by which the chamber is mounted to a 10 metre length of low noise triaxial cable to a BNC triaxial plug and is provided with a Triax TNC converter. Performance Energy response uniform +/- 1% from 1.0mm AL 20mm AL HVL (0.030mm Cu to 4.00mm Cu HVL) Sensitivity 11nC/Gy nominal Better than +/ over 3 years Polarising potential 200V / Max +/-400 V DC Collection efficiency (HV@-200V) - continuous radiation better than 99.9% for dose/pulse values less than 43.5 microgy Leakage better than +/-2X10 E-14A Active Dimensions Specification Sensitive Volume 325mm 3 Length of volukme 9.22mm Thimble wall thickness 0.5mm Diameter 7.35 mm Key Features: Air Vented Chamber so air density corrections are to be applied The chamber is manufactured in the UK by the NPL (National Physical Laboratory) Maintenance and Calibration are carried out by NPL Secondary Standard calibrations for Electrons and Photons are carried out normally twice per annum and are available directly from NPL Exterior Dimensions Materials Reference Point Venting Build up Cap Cable Length 185mm Diameter 12.5 mm Thimble high density (1.80b/cm 3 ) high purity extruded graphite Collecting electrode - aluminium 99.99% pure Main insulator amber stem insulators P.C.T.F.E. HV insulator Delrin The chamber stem is guarded to a point 15mm from the measuring Volume The effective measurement point for positioning the chamber should be taken to be the axis of the chamber 5mm from the tip of the graphite thimble To ensure that the chamber is equilibrated with the atmosphere the measuring volume is vented giving pressure equilibration times for just a few seconds Delrin, with external diameter of 17.0 mm and wall thickness of 600mg/cm 2 Suhner GO 233OHT connections Centre core signal at HV Inner screen guard at HV Outer screen earth potential Length 10m Accessories: NPLSL Water Proof Sleeve (one delivered with each new chamber) NPLCDC Sleeve to accommodate NPL-2611 into IBA CDC Check Source see left picture NE2566A Perspex Phantom for Intercomparison between Farmer Type and 0.33cc Secondary Standard Chambers 3

7 Bespoke Detector Holders for Phantoms and Check Sources Phoenix Dosimetry offer a service for the provision of bespoke detector holders and adaptors for a variety of Phantoms and Check Sources. We provide adaptors for the IBA CDC Check Source including the NPL- 2611, Standard Imaging A1SL Chamber, PTW Semiflex 3D and many other types. We can also customise these for specific requests. A1SL Insert for IBA Check Source NPL-2611 Insert for IBA Check Source Build up caps are also available for the NE2571/ NE2581 Chambers manufactured from Brass and other materials upon request. Specifications are also available. Phoenix Dosimetry offer a repair service for NE2571 and NE2581 Chambers together with extension cables. Please enquire for further information. NE2566A Rod Inserts are available for other chamber types to allow inter-comparison with another chamber. Please enquire for further information. Bart s Solid Water Intercomparison Phantom with scribed marks both sides for the NE2571 and NPL-2611 Chambers. 4

8 Accessories for the NE-2571 and NE-2581 Chambers Phoenix Dosimetry now offer a wide range of accessories for the Farmer Chambers together with spare parts. We have a full service capability at our workshop in Sandhurst and are able to both repair and rebuild the chambers at a very reasonable price. Many older chambers become fragile with extended use including the Shonka Plastic thimbles on the NE Why not give your old chambers a new lease of life? Just send them to us and we will send you a no obligation quote for the cost to update them to the latest specification. Accessories Include: Thimble Repair Kit (Part No: 2542/3A) for the NE which includes 2 Thimbles and 2 Collets cleaned and prepared for use and 2 spanners in a case Thimble Repair Kit (Part No: 2542/3C) for the NE-2581 which includes 2 Shonka Plastic Thimbles cleaned and prepared for use and 2 spanners in a case Waterproof Plastic Sheath for NE-2571 or NE-2581 for use in a Water Phantom Latex Sheath (Part No: 2513B) - length at 1 meter long Brass Build up caps available in other materials and to user specified sizes Extension Cables Chamber case with protective foam insert Solid water Blocks milled out for the NE- 2571/2581 Adapter Rods for the NE-2566A Intercomparison Phantom also available for other chamber types Other parts are available upon request, please us at sales@phoenix-dosimetry.co.uk Chamber Repair Kit Waterproof Plastic Sheath Build Up Caps 5

9 High Quality Customised Dosimetry Extension Cables and Patch Panels Phoenix Dosimetry offer custom made Dosimetry Cables for Radiotherapy and associated departments. We offer a wide range of connectors including Triax TNC, Banana BNC etc. The cables are specifically manufactured to customers individual requirements and we pride ourselves on a fast delivery service. The range of cables available includes, but is not limited to: Triax TNC extension cables up to 60m length these are suitable for Farmer type chambers for connecting to a range of precision Electrometers Triax TNC to Banana BNC cables / adaptors for use with NACP chambers Triax BNC connectors can also be fitted if required RJ-45 Network Cables Bulk Head connectors also available Patch Panels We offer customised patch panels which would be located in the Linac control room and main Linac room. Patch Panels make for a tidy environment with clear labeling to avoid ambiguity when connecting up different chambers QA equipment. We can also include network and DIN connectors. 6

10 BNC Triax 2 Lug Threaded Triax TNC BNC Triax Male (L) and Female (R) Part No: Male = PD1 BNC Triax Male Part No: PD1 BNC Banana Triax TNC Female (top) and Male (bottom) Part No: Male = PD3 BNC Triax 3 Lug BNC Banana Female genders shown Part No: Male BBNC = PD9 Female BBNC = PD10 Converters BNC 3 lug Triax Male Part No: Male = PD5 Converter for NPL 2611 Chamber which is now supplied with Triax BNC plug converts to Triax TNC M Type Connector 7

11 Patch Panels from Phoenix Dosimetry Phoenix Dosimetry now offer custom made Patch Panels and Extension Cables for Radiotherapy and associated departments. We offer panels which are built to your specifications in terms of the size, detector types and labeling. Example Patch Panels: The panels are produced with engraved lettering on hard anodised aluminum plates and typically take 3 weeks to produce. Why use Patch Panels? The use of patch panels is now increasing rapidly as customers realise the many benefits which include: Cable management; eliminates the need to run cables around the maze or through rat runs. The cables between the patch panels are never moved which makes them more reliable. Easy identification of which channel the cable is connected to making set up faster and easier. All common QA connections are catered for e.g. Triax TNC, 2 and 3 lug BNC, Sun, RJ-45, HDMI, Network, RS-232, USB etc. Optional mounting of the panel in a protective steel box (see picture RHS) and also versions so that the excess/ extension cable can be stored, if required, within the box. If you would like a quotation then please us with your requirements which should include the connector types, size of plate and distance between the 2 patch panels. 8

12 PEP Phantom Phoenix Electron Photon Water Phantom The 2611 Special PEP Holder Accepts both the NPL-2611 in its waterproof sleeve alongside the Farmer chamber in a vertical orientation at 2 cm from the external surface of the side window: The PEP Phantom has many applications and was originally designed for Electron Dosimetry to meet the requirements of the Electron Code of Practice; however it has also proved excellent for Photon Dosimetry. We have recently redesigned the PEP Phantom, removing all ferrous parts to make it MRI compatible. Material: Specification 10mm clear acrylic The unit comprises a compact and robust water phantom complete with a levelling platform suitable for both chamber and treatment machine calibration / output measurements. It is capable of accepting all chambers recommended in the Electron Code of Practice. The unique rotational chamber mounting, and the opposed thin windows, allow for measurements to be made with both vertical and horizontal beam incidence. Vertical chamber position is continuously variable. Lateral chamber positioning can also be easily achieved. Internal Dimensions: External Dimensions: Range of Movements Levelling Capability: Weight Empty: Weight Full: Acceptable Chambers: 350mm(l)x294mm(w) x 300mm(d) Thin Windows: 3mm clear acrylic x 150mm diameter 420mm(l) x 400mm(w) x 390mm(h) Depth: 250mm with 1mm scale (continuously variable) Lateral: 240mm in 10mm intervals Three point levelling platform Drain Hole: 8kg 39kg NACP, Markus, Roos, NE2571, NE2581,IBA IC70 and PPC-40, NPL2611 others upon request. Ordering Information The unit comes supplied with 2 chamber holders, one for the Farmer thimble chamber and the other for a parallel plate chamber of the customers choice. Additional chamber mountings available on request. Also available is the NPL-2611 Special Holder pictured above. 9

13 NE2566A Phantom The NE2566A is a solid Perspex phantom for the calibration of Farmer cylindrical chambers (e.g. NE-2571) against a secondary standard (NPL Therapy Level system) by supporting both chambers in exactly reproducible geometries at the recommended depths in the calibration beam. It can be used for X and Gamma ray calibration over the range 150kV to 50MV. NE2528/3 Small Water Phantom Internal Height Dimensions 200mm The NE2528/3 is a small portable water phantom comprising a strong Perspex (Polymethyl methacrylate) box containing a transverse tubular sleeve into which the 0.6cc Farmer Ionisation Chamber 2505/3 fits. The centre of the chamber volume aligns exactly with the intersection point of reference lines engraved on the beam entrance side of the box. A small sprung clip prevents the chamber moving during use. The useful energy range is 150kV to 10MV. Internal Width Internal Depth Wall Thickness front Beam Entrance -Back -Top, Base and Sides Thickness of wall surrounding chamber thimble 200mm 100mm 3.2mm 12.7mm 6.4mm 4.6mm Distance of wall surrounding chamber thimble 50mm (Water equivalent) Weight Empty Weight Full 1.5kg approx 5.5kg approx 10

14 Bart s Solid Water for Electrons and Photons Solid Water The Bart s Solid Water was originally developed by David White and has undergone continual improvements with new production facilities now in place at Bart s Health NHS Trust. We are able to offer customised sizes from 1mm thick upwards with user specified thicknesses e.g. 41mm. We also offer various sizes 20 X 20, 25 x 25, 30 X 30, 35 X 35 cm etc. The Bart s Solid Water mimics the absorption characteristics of water over a wide range of energies. Radiation beam calibration is made simpler when using Solid Water. It is designed to scatter and attenuate radiation in the same way as water and can be easily machined to accommodate custom chambers and detectors. We also precision machine cavities in slabs of 2.0cm thickness or greater to accommodate most commercially available ion chambers/ detectors. Features: Wide range of sizes and dimensions Mouldable material for custom requests Rigid construction eliminates broken ion chambers Wide range of applications and uses Dedicated Solid Water (WTE) for Electrons available New proton Solid Water available shortly Benefits: Solid Water allows for calibrations within 1% of the true water dose Useful in relative ionisation calibration, depth dose measurements and absolute calibrations Readily machined for custom sizes Bart s was the original Solid Water and reference information is available in many scientific publications Electron and Photon Stopping power relative to water of / for Photon energies from 100kV to 24MV See picture to the right showing a cut out for the PTW Roos chamber which includes the plug shown to enable simple removal of the chamber obviating any damage. 11

15 NEW Brass Bolus now available Bolus and Tissue Equivalent Materials In addition to specialised WTE and WT1 Solid Water equivalent materials for Electrons and Photons, we now offer other types of mimicking materials; these include Adipose, Breast, Bone, Lung etc. These materials are available in the same standard sizes as the Solid Water but can also be purchased to user defined shapes for phantoms and test blocks. Bart s Bolus Bags offer soft comfortable muscle or water substitute material for use in Megavoltage Radiotherapy. A list of the specialised tissue equivalent materials are listed below, these can be purchased to user specified shapes and sizes. The bags are supplied in standard sizes and are manufactured from highly elastic film offering excellent durability, further information is available on our Bolus data sheet which can be downloaded from our website. Electron Density relative to water Adipose (Fat) Tissue AP Breast Tissue BR Hard Cortical Bone SB Inner Bone IB Average Rib Bone RB Lung Tissue LN Liver LV Please contact our Sales Office for further information on any of these products. 12

16 Mould Room Products from PAR Scientific ACD-4 MK5 Automatic Block Cutter by PAR The ACD-4 MK5 is the very latest automatic Block Cutter for Radiotherapy Mould Rooms available from Phoenix Dosimetry. Key Characteristics Small lightweight table model that can be placed in any location 4 th Generation electronics offer clinically proven reliability Modern 32-bit software package (Win7/ Win10 compatible) with optional Dicom Daemon DicomRT is supported Very fast cutting speed Very fast adjustability of Styrofoam block sizes from 380 x 380 mm and lower with full flexibility on selected size "Plug-and-play" functionality for fast and easy installation Full accessory package: PAR label Printer, PAR Foam and CadFree Alloy. Cutting Accuracy Cutting Speed Active cutting area Size Weight Software: Accessories: Specification Better than 0.5mm 10 mm per second 380 x 380 mm - adjustable L: 72 cm W: 38 cm H: 72 cm 30 Kg Full Windows with DICOM RT I/f Label Printer Alloy melting pots Cooling plates Scanners VacFix Vacuum Cushions VacFix Vacuum Cushions are the original, high quality reliable vacuum fixation cushions. It has the thinnest plastic foil available to reduce the build-up effect to a minimum - yet extremely ridged and resistant towards foil rupture. The ability to mould very fine structures and thereby include the highest number of fixation points provides the optimal reproducibility - a more and more vital issue in modern Radiotherapy and diagnostic procedures. Our famous flexibility towards customized sizes, shapes and fillings combined with a very fast production time makes it possible and very easy for the user to have their own design to meet the exact local demands and specifications. This flexibility is only available by Par Scientific A/S. 13

17 Eckert & Ziegler QA Phantoms Quality Assurance Tools Isocentric Beam Checker I Isocentric Beam Checker IV The Isocentric Beam Checker IBC I, is used to precisely determine the isocentre of any radiation therapy machine. It checks the alignment of the side / laser lights used for patient set-ups in radiation therapy, conventional tomography, and CT scanning. Isocentric Beam Checker II Tungsten markers of 2 mm diameter are embedded in the centre and corners of the fields. The multifunctional Isocentric Beam Checker, IBC II, consists of a large opaque acrylic screen backed by a secondary plate, both supported by two lateral uprights. The screen is inscribed with lines precisely defining corners, edges, and centre of the screen's 2mm x 2mm, 5cm x 5cm, 10cm x 10cm, 15cm x 15cm, and 20cm x 20cm fields. Isocentric Beam Checker III The Isocentric Beam Checker, IBC III, is designed to facilitate routine quality assurance tasks required daily, weekly or monthly on linear accelerators or Teletherapy units. Numerous mechanical parameters can be tested in a very short time due to the simplicity of the set-up. The Isocentric Beam Checker, IBC IV, is a QA phantom, manufactured to ISO specifications, for performing Quality assurance checks as recommended by TG-142. The IBC IV can perform monthly checks of MV imaging system and treatment coordinate coincidence, MV scaling, kv Imaging system and treatment coordinate coincidence, kv scaling, and kv positioning / repositioning (shifts). PermaDoc Phantom The PermaDoc Phantom provides the necessary permanent documentation required by the NRC quality assurance tests associated with HDR. The PermaDoc Phantom, with its centimetre scale automatically transferred to the film by fluorescent radiation, readily identifies up to 20 source positions and their stepping accuracy. PermaDoc GC Phantom See our website for other QA Phantoms The Gafchromic PermaDoc GC Phantom is designed to check source positioning and stepping accuracy of HDR remote afterloading systems and provides a permanent record. It has a centimetre scale, which is projected onto the Gafchromic RTQA film by fluorescent radiation, and readily locates, up to 20 source positions. 14

18 Aegis ED3 Real Time Extremity Dosemeter The monitoring of extremities is extremely important when handling radiopharmaceuticals as whole body dose badges will underestimate the real extremity dose, especially in high dose gradients. The ED3 is ideal for a range of applications including cardiology, oncology, X-ray and general glove box work. The ED3 Active Extremity Dosemeter allows for simple monitoring of Hp(0.07) for betas and gammas on the extremities with 2 types of probe available depending on the energy range to be covered. The Probes come pre-calibrated and are interchangeable on the ED3 electronics units. Key Characteristics Real-time readout for 1 or 2 detectors Measures Hp(0.07) directly Detectors are detachable so ideal for decontamination or replacement Collected data can be analysed, stored and archived on a PC using the ED3 Manager software which is included with the ED3 Can be utilised for Hp(3) Eye dosimetry by the addition of a 3mm filter and head band Applications; Interventional Radiology Radiation therapy Nuclear Medicine Glove Box High Dose Gradient Environments X-Ray Benefits: Real time monitoring with long battery life and data storage for post analysis / dose records Improved dose assessment in high dose gradients Simple to use and wear Energy Range photons Effective Dose Range Effective Dose Rate Range Size & Weight Environmental Display Specification 25 kev 1.2 MeV 1.0 µsv msv 0.1 mrem mrem 0.0 to 99.9 msv/h 0.0 to 9.99 rem/h 99 x 60 x 35 mm 245 g IP53 16 x 2 character LCD Battery Life (Rechargeable) Over 60 hours per charge with normal use Self Test and Alarms Low Battery Missing Probe Dose Alarm Dose Rate Alarm Dose Rate Overload Dose Over Range 15

19 Harshaw TLD Readers and Materials Model 5500: TLD Reader for the automated processing of up to 50 loose chips / pellets Phoenix Dosimetry Ltd are the appointed UK and Irish distributor for Thermo Electron. We offer the full range of Harshaw TLD Readers and Materials together with accessories. The range of Readers are ideal for various applications of Radiation Dose Monitoring including: Personal Dose Monitoring (whole body and Extremity) Diagnostic Surveys Patient Dosimetry Environmental Monitoring High Dose / Accident Dosimetry Food irradiation monitoring TLD Materials We supply a complete range of materials ranging from powder, loose chips, TLD cards, Dxt-Rad Extremity rings, Ext-Rads, Holders etc. Model 3500 Model 4500 Model 5500 Model 6600 Model 8800 TLD Irradiators Upgrades Readers For manual processing of loose chips, pellets and powder For manual processing of loose chips, pellets, powder and cards For automated processing of loose chips, pellets and microrods / cubes For automated processing of Cards and Extremity Dosemeters (200 / loading) For high capacity automated processing of Cards and Extremity Dosemeters (1,400 / loading) We offer a stand alone Irradiator and an integrated one for the M-6600 and M-8800 Readers Please contact our sales office for information on mid life upgrades and Windows 7 compatible WinRems Software 16

20 TLD Accessories TLD Card Storage The Harshaw TLD Card Storage System conveniently stores large quantities of Harshaw TLD cards and is able to load or unload them directly into / from the M-6600 and M-8800 load cartridges for simple and safe handling. This system is compatible with both the Harshaw TLD Model 6600 and 8800 Card Readers and the user can define the storage size required, normally vertical columns store up to 600 TLD cards TLD-3 Annealing Oven The TLD-3 Oven is designed especially for TLD annealing with a programmable controller, two fans, one for air circulation and the other for assisted cooling and a maximum temperature of 4000C. The programmer can be ordered with the option for multiple programmed cycles to allow for different materials to be annealed TLD Annealing Trays Fabricated from Stainless Steel each tray takes 100 chips, pellets or rods. Trays are engraved with labels A-J and 1-10 TLD Vacuum Tweezers are also available, details upon request 17

21 TLD Accessories WrapIDIssuer The WrapIDissuer is designed specifically for the fast and efficient issuing of Harshaw TLD cards for medium to large scale TLD Personal Monitoring Services using Harshaw TLD systems. The unit comes complete with its own software which allows the importation of a file containing a list of wearers in either CSV or XML formats, and then issues a card to that wearer and wraps the card in a mylar foil packet and exports files in the same format. Files to be imported will contain an issue list of wearers for cards to be issued to. SCANAROUND for Harshaw DXT-RADs The Scanaround circular barcode reader has been especially designed to read the barcodes on DXT- RAD type dosemeters where the dosemeter is either behind a lens in the ring type holder or as a discrete dosemeter. A camera and lens are used to obtain an image of the dosemeter from which the barcode is extracted. On-screen displays show interactively the barcode readout process. The system works in conjunction with a PC where the resultant code is then sent out via a serial RS232 port; it can also be sent to a user selectable file. In the case where the RS232 output is used, the receiving PC can use a software wedge whereby the code appears as though typed in at the cursor location. The software can be run on the same PC as the Data receiving software. 18

22 RadEye Portable Radiation Monitors Thermo Health Physics RadEye s and Portable Radiation / Contamination Monitors There is a RadEye monitor for almost every application. RadEye AB-100 with dual large area scintillator probe for alpha beta gamma, also has inbuilt discriminator RadEye NL Neutron version RadEye B-20 Ideal for Nuclear Medicine Departments / Low energy detection RadEye PRD with Sodium Iodide Scintillator for high sensitivity survey monitoring Ion Chamber Survey Monitors: RIIDEye Portable spectrum analyser for identification of Isotopes. RadEye SX Configurable to work with most popular scintillation probes. Above: Smart ion with microprocessor and data logging function for beta gamma and x-ray Below: R0-20 Air filled ion chamber for Beta/ Gamma detection with thin window A Range of Probes including the DP6 Alpha / Beta version above and DP-2 below RadEye SPRD to detect, locate and identify radionuclides. Products shown here are a sample of the overall portfolio. We also offer cables and accessories covering the entire range. We carry demo models and are normally able to demo/loan out equipment for evaluation purposes. 19

23 EPD-2 Real Time Dosemeter Mini Monitors Lutetium Test Adapters RadEye fitted to Mini type probes RadEye SX and GX The EPD-2 is a fully approved personal Dosemeter and is ideal for the monitoring of personnel with real time display of HP(10) and HP(0.07) Robust construction High reliability Very high immunity to EM interference Standard AA battery Non-contact Infra-Red readout LCD display for wearer Sounder ~ db(a) Special EPD Starter Package comprises: Mini Monitors Models Available: 900 Scintillation version (shown above) 2100S and 2103S Ion Chamber Survey units for Beta, Gamma, X-ray 7-10 Mains operated Radiation Alarm with Audio/ Visual display 5 or 10 Grey Beta Gamma EPD Mk2+ dosimeters, Infra Red reader with USB interface, Easy EPD2 and EasyIssue software. EPDs are provided with alligator belt clip, lithium battery and coin battery cap. Utilise your old Scintillator and Geiger Probes with the RadEye SX and GX The RadEye SX and GX can be linked to more or less all existing Scintillation and Geiger detectors by means of a simple low cost cable, we'll even set them up for you free of charge in our workshop. Lutetium Test Adaptors are useful as a check source but fall outside the legal requirements for a radioactive source, hence they do not require any licenses and, due to the long half life, would never need replacing. There would also be no significant disposal cost. 20

24 Radiation Gate Monitors for Power Stations, Scrap Yards & Industrial Facilities The Thermo Gate monitors are well established and ensure that they give you the best possible detection against rogue sources entering or leaving sites. The units incorporate large area plastic scintillation detectors. We offer the ASMIV and FHT-1388 units, both have intelligent algorithms to ensure excellent detectability but with minimal nuisance alarms. We also offer a full installation and ongoing maintenance so any issues can be quickly resolved. Our engineers are based in Sandhurst, are factory trained and have a full inventory of parts. FHT1388 Detector Configurations ASM-4 Controllers and Detectors Gamma only detection systems can miss orphan Alpha emitting sources such as Americium. The FHT 1388S /SGS-2: Neutron Module (shown below) can be added to enable Neutron detection. 21

25 Thermo/NE Repairs to Mini Radiation Monitors Phoenix Dosimetry now offer an express repair service for Mini Instruments and NE/Thermo Legacy equipment. Our newly refurbished bench repair facility has a team including Ken Bosley, who has a wealth of experience in these equipments over the past 30 years! The range covered includes all the Mini and Legacy NE/Thermo equipment, the only limiting factor may be the availability of parts for some of the much older equipment but in most cases we can normally effect repairs. Please contact us if you require any further information. The range includes the list below but is not exclusive to the these units: Dose Rate Monitors: 900 series 900 Series GM tube and scintillation detector based contamination monitor 2100 series ion chamber survey meters 7-10 Mini alarm with MC10, MC20 and MC70 probes Monitors by NE including Electra s, PCM s and PDR s and RM series type R, RL and CM11 s HM9 and associated equipment NE Radiological Farmer Electrometers, Dosecheckers, Farmer Chambers (new and rebuilds) Please contact us as we offer a free inspection service which is followed up by a report and a no obligation quotation prior to any works commencing. Should you decide not to proceed then we will simply return the instruments OR dispose of them as requested. 22

26 Phoenix Dosimetry Technical Support, Training and Service Optimal performance of your Dosimetry equipment relies on regular and efficient service support. Phoenix Dosimetry have excellent service facilities encompassing both bench repair and field service; we offer a range of Service Contracts tailored to meet individual customer requirements. Our staff have over 30 years of experience in supporting Radiation Monitoring Systems. Contract Types: We hold a comprehensive inventory of parts for most systems at our workshop facilities in Sandhurst and are able to respond quickly to any emergency breakdowns. We offer upgrades and refurbishments for older units including Health Physics and Radiological instrumentation to bring them up to the latest specification. 23 Fully Comprehensive Includes 2 planned preventative visits per year with all parts and labour plus emergency call out Preventative with 2 Visits per Year Includes 2 planned preventative visits per year. Any parts and emergency call out at additional charge Preventative with 1 Visit per Year Includes 1 planned preventative visit per year. Any parts and emergency call out at additional charge Bench Repairs We charge per hour for any repairs and there is no inspection charge so you can send your instruments to us and obtain a no obligation quotation for their repair

27 Performance Testing / Calibration Testing for Thermo EPD s and JCS ED3 Real Time Dosemeters We are now offering, In partnership with John Caunt Scientific, an express annual performance test for the ED3 Extremity Electronic Dosemeter Probes. ED3 Detector Probes should be checked annually to ensure their response to radiation is within specification. For the D1 Probe angular response is checked to confirm the integrity of the internal filters. To use this service simply us at support@phoenix-dosimetry.co.uk and let us know how many and which type of units you would like us to test / cross calibrate Sample Test Certificate Phoenix Dosimetry in partnership with Thermo Fisher Scientific now offer an express calibration service for the EPD-2 Personal Electronic Dosemeters. Our laboratory is now fully equipped with the essential Thermo Fisher calibration and test equipment which is specifically designed for the EPD-2 units. Turnaround times are typically 1 week. Please us now for any further details at support@phoenix-dosimetry.co.uk 24

28 About Phoenix Dosimetry: Phoenix Dosimetry Ltd is a company who specialise in providing equipment and services to the Dosimetry market. Our core areas are in Radiotherapy and Health Physics, to both industrial and Hospital environments. Our staff have over thirty years experience in providing our customers with unique solutions and advice for all aspects of Dosimetry and Radiation monitoring. We have teamed up with some of the biggest companies from around the world to provide the best equipment to meet our customers' requirements. These include Thermo Fisher incorporating Harshaw TLD, Par Scientific, John Caunt and NPL. In addition we also provide a variety of Phantoms, Farmer Chambers, customised Dosimetry cables and Patch Panels. Our newly refurbished offices in Sandhurst provide the back office support one would expect from a company dedicated to providing the best customer experience. Our Sales and Service team are based from here and travel throughout the UK and Ireland to provide on-site demonstrations, service and maintenance support. We can also facilitate training and demonstrations of equipment in our new training room. Please visit our website for further information and details of all our products and services. Contact: sales@phoenix-dosimetry.co.uk Telephone: +44 (0) Phoenix Dosimetry Ltd Unit 8, Lakeside Business Park, Swan Lane, Sandhurst, Berkshire GU47 9DN

Telephone: +44 (0)

Telephone: +44 (0) Radiation Monitoring Devices Phoenix Dosimetry Ltd www.phoenix-dosimetry.co.uk Telephone: +44 (0)1252 871990 Unit 8, Lakeside Business Park, Swan Lane, Sandhurst, Berkshire GU47 9DN Radiation Monitoring

More information

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System FEATURES: HIGH GAMMA SENSITIVITY MULTI-CHANNEL ANALYZER (MCA) WORKS WITH VARIETY OF PROBES RADIONUCLIDE LIBRARY TAILORED TO CUSTOMER REQUEST SIMULTANEOUSLY MEASURES ; DISPLAYS; ALARMS 1-3 SEPARATE DETECTORS

More information

Maximize safety and productivity. Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions

Maximize safety and productivity. Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions Maximize safety and productivity Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions Monitoring solutions to optimize safety, efficiency and compliance Our years of expertise and

More information

Victoreen & 660-8

Victoreen & 660-8 Victoreen 660-6 500-100 6000-100 660-7 & 660-8 CT Probes and Phantoms Operators Manual March 2005 Manual No. 660-6-1 Rev. 3 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product

More information

Maximizing safety and productivity. Nuclear Power Radiation Detection and Monitoring Solutions

Maximizing safety and productivity. Nuclear Power Radiation Detection and Monitoring Solutions Maximizing safety and productivity Nuclear Power Radiation Detection and Monitoring Solutions Growing portfolio You can depend on Thermo Scientific radiation detection and monitoring solutions to optimize

More information

Radiation Monitoring Systems

Radiation Monitoring Systems Radiation Monitoring Systems Certificate No. 3250 Contents A guide to Southern Scientific radiation monitoring systems Area Gamma & Interlock Systems (page 3) AGM3 AUTOMESS 6150 Contamination Monitors

More information

Dosimeters/Survey meters

Dosimeters/Survey meters Dosimeters/Survey meters 40 Gracechurch Str., EC3V OBT, London, United Kingdom (24 Hour Customer Line) 0044 208 720 6926 RAD-ION (RI-02) Especially designed for the Detection of Pulsed (Golden Engineering)

More information

Our Extended Personal Electronic Dosimeter (PED) Family

Our Extended Personal Electronic Dosimeter (PED) Family Our Extended Personal Electronic Dosimeter (PED) Family Tracerco s Award Winning Radiation Monitors and Servicing business unit provides a range of products and services accredited to ISO9001:2008 and

More information

Portable Survey Instruments NISP-RP-01

Portable Survey Instruments NISP-RP-01 NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection NISP-RP-01 This is an industry document for standardizing radiation protection processes used by supplemental radiation protection technicians.

More information

Identify the following features and specifications for the ESP1

Identify the following features and specifications for the ESP1 LEARNING OBJECTIVES: 2.17.01 List the factors which affect an RCT's selection of a portable contamination monitoring instrument, and identify appropriate instruments for contamination monitoring. (Also

More information

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter NAKASHIMA, Sadao * MAEKAWA, Osamu * ABE, Shigeru * A B S T R A C T Conventional radiation exposure management methods included

More information

Co-60 irradiator for therapy level calibrations at SSDLs

Co-60 irradiator for therapy level calibrations at SSDLs SPECIFICATION Co-60 irradiator for therapy level calibrations at SSDLs Prepared by: Igor Gomola, Technical Officer for TC Project ISR6021 Date: 2014-Aug-04, Rev.08 Page 1 1. Scope and Background This document

More information

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31 User s Manual Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30 Fuji Electric Co., Ltd. TN514629i 1/31 Introduction Thank you for purchasing the Electronic Personal Dosimeter NRF30 (Hereinafter described

More information

RIID capability in the palm of your hand

RIID capability in the palm of your hand RIID capability in the palm of your hand Thermo Scientific RadEye SPRD-GN Personal Radiation Detector Changing the game The Thermo Scientific RadEye SPRD-GN delivers unprecedented detection. The first

More information

Competency: Critically evaluate the function of the ionisation chamber in the Linear Accelerator and its importance for correct treatment delivery

Competency: Critically evaluate the function of the ionisation chamber in the Linear Accelerator and its importance for correct treatment delivery Competency: Critically evaluate the function of the ionisation chamber in the Linear Accelerator and its importance for correct treatment delivery Trainee: TRAINEE Module: Radiotherapy Physics Competency:

More information

Quality Assurance of Radiation Protection Monitoring Instruments in India

Quality Assurance of Radiation Protection Monitoring Instruments in India Quality Assurance of Radiation Protection ing Instruments in S.M. Tripathi*, Liji Daniel, Suresh Rao and D.N. Sharma Radiation Safety Systems Division, Bhabha Atomic Research Centre Mumbai-400085, Abstract.

More information

Ionisation Chambers Containing Boron as Neutron Detectors in Mixed Radiation Fields

Ionisation Chambers Containing Boron as Neutron Detectors in Mixed Radiation Fields Pol J Med Phys Eng 2007;13(2):79-91. PL ISSN 1425-4689 doi: 10.2478/v10013-007-0007-4 website: http://www.pjmpe.waw.pl Michał A. Gryziński, Piotr Tulik, Mieczysław Zielczyński Ionisation Chambers Containing

More information

MapCHECK 3. The New Benchmark for 2D IMRT QA. Your Most Valuable QA and Dosimetry Tools

MapCHECK 3. The New Benchmark for 2D IMRT QA. Your Most Valuable QA and Dosimetry Tools MapCHECK 3 The New Benchmark for 2D IMRT QA Your Most Valuable QA and Dosimetry Tools THE NEW BENCHMARK FOR 2D IMRT QA The MapCHECK family is the world s most selected independent 2D measurement array,

More information

Setting the new standard for personal radiation detection.

Setting the new standard for personal radiation detection. Setting the new standard for personal radiation detection. Thermo Scientific RadEye SPRD Personal Radiation Detector Definitive answers through pin-point accuracy The Thermo Scientific RadEye SPRD personal

More information

for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications

for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications custom scintillation at the core of your optical system High sensitivity

More information

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (Amends In Its Entirety)

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (Amends In Its Entirety) NO. : NC-646-D-128-S DATE: February 23, 2012 PAGE: Page 1 of 8 MODEL No.: 3241-C, 3241-D & 3241-G MANUFACTURER/DISTRIBUTOR: Troxler Electronic Laboratories, Inc. P.O. Box 12057 3008 Cornwallis Road Research

More information

Any scenario. Maximum protection. Radiation detection solutions for safety and security

Any scenario. Maximum protection. Radiation detection solutions for safety and security Any scenario. Maximum protection. Radiation detection solutions for safety and security Radiation detection solutions for security personnel Delivering dependable safety and security solutions for over

More information

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection Level 3 Information Use NISP-RP-001 Industry Approval Date: September 14, 2018 This is an industry document for standardizing radiation protection

More information

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL AM-806 Waste/Door Radiation Monitor OPERATIONS MANUAL Section Contents 1. SPECIFICATIONS 2. MAIN COMPONENTS 3. THEORY OF OPERATION 4. OPERATING INSTRUCTIONS 5. INSTALLATION Page 2 1.0 SPECIFICATIONS SENSITIVITY

More information

Nuclear Associates

Nuclear Associates Nuclear Associates 05-575 MiniMonitor III Multipurpose X and Gamma Ray Survey Meter Operators Manual February 2005 Manual No. 05-575-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed

More information

HEALTH AND SAFETY MANUAL

HEALTH AND SAFETY MANUAL HEALTH AND SAFETY MANUAL Title: Ionizing Radiation Approved by: Greg Savoy Rev. 3/1/13 1.0 Purpose The purpose of this safety policy is to establish guidelines for the protection and safety of Compay employees

More information

User Manual. Advanced Markus Chamber Ionization Chamber Type 34045

User Manual. Advanced Markus Chamber Ionization Chamber Type 34045 User Manual Advanced Markus Chamber Contents Operating Manual Technical Manual Service Manual D661.131.00/05 en 2013-03 ext/hn General Information General Information The product bears the CE-mark "CE

More information

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES: LEARNING OBJECTIVES: 2.17.01 List the factors which affects an RCT's selection of a portable contamination monitoring instrument. 2.17.02 Describe the following features and specifications for commonly

More information

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS EML-624 A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS FOR HOMELAND SECURITY PURPOSES Paul Bailey Environmental Measurements Laboratory U.S. Department of Homeland Security 201 Varick Street,

More information

COMPONENT SOLUTIONS for the lighting industry

COMPONENT SOLUTIONS for the lighting industry COMPONENT SOLUTIONS for the lighting industry optimascomponents.com QUALITY, COMPONENTS & SERVICE OPTIMAS COMPONENTS CHINA, DESIGN & SOURCING Component Solutions for the Lighting Industry Optimas Components

More information

PROFILER Family IC PROFILER, IC PROFILER - MR & SRS PROFILER. Your Most Valuable QA and Dosimetry Tools

PROFILER Family IC PROFILER, IC PROFILER - MR & SRS PROFILER. Your Most Valuable QA and Dosimetry Tools PROFILER Family IC PROFILER, IC PROFILER - MR & SRS PROFILER Your Most Valuable QA and Dosimetry Tools THE INDUSTRY STANDARD Every clinic should have a PROFILER. The PROFILER family of 2D arrays share

More information

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

Portable Alpha/Beta Continuous Online Air Monitor (CAM) Aer 5000 Desktop Portable Alpha/Beta Continuous Online Air Monitor (CAM) The Aer5200 monitors the ambient air continuously to detect airborne radioactive aerosols (LLRD). Typical application fields are

More information

Advantages / Characteristics

Advantages / Characteristics Air to Air 50 W 30 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 70 W 36 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 75 W 30 W cooling capacity 130x109x163mm (LxBxH) 1,5 kg

More information

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer JAN 0 ::0 AM SERVOLOCK APPLICATION NOTE 0_0_ Rev Using the Deluxe Dew Point/ Humidity Hygrometer The Model is a versatile, multi-function, optical chilled mirror hygrometer designed to continuously measure

More information

CALIBRATION OF A GAMMAMED 12i 192 Ir HIGH DOSE RATE SOURCE

CALIBRATION OF A GAMMAMED 12i 192 Ir HIGH DOSE RATE SOURCE VI. simpozij HDZZ, Stubičke Toplice HR0500041 CALIBRATION OF A GAMMAMED 12i 192 Ir HIGH DOSE RATE SOURCE Tomislav Bokulić, Mirjana Budanec, Iva Mrčela, Ana Frobe and Zvonko Kusić Department of Oncology

More information

Laboratory Impex Systems Ltd

Laboratory Impex Systems Ltd Laboratory Impex Systems Ltd Introduction to Lab Impex Systems & News Jeff Sawyer & Jeff Rivers Laboratory Impex Systems (LIS) Specialize in the design and manufacture and supply of health physics, radiation

More information

Battery-operated, hand-held alarm and measuring instruments for radiation protection

Battery-operated, hand-held alarm and measuring instruments for radiation protection Battery-operated, hand-held alarm and measuring instruments for radiation protection The GRAETZ alarm dosemeter ED150 warns the task force when the defined radiation dose for the operation is reached.

More information

RadEye N / NL Personal Highly Sensitive Neutron Radiation Detector

RadEye N / NL Personal Highly Sensitive Neutron Radiation Detector JRT Associates New pocket size neutron radiation detector 5 Nepperhan Avenue, Suite 2B Elmsford, NY 10523 800-221-0111 RadEye N / NL Personal Highly Sensitive Neutron Radiation Detector High sensitivity

More information

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020 Earphones The Modular System for Radioactivity Measurements For the connection to the separate earphone output. This enables the simultaneous operation of external FH 40 G probes and earphone. For the

More information

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020 The Modular System for Radioactivity Measurements FH 40 G/GL Digital Survey Meter FHT 6020 Display Unit Rugged and reliable Versatile multipurpose meter and area monitor Data logging Internal detector

More information

Laser Automation &Safety. ME 677: Laser Material Processing Instructor: Ramesh Singh 1

Laser Automation &Safety. ME 677: Laser Material Processing Instructor: Ramesh Singh 1 Laser Automation &Safety 1 Outline Laser Automation Laser Sensing Safety Considerations 2 Automation The Ford Motor Co. Introduced "automation in the 1940s Machines were used to enhance speed, force or

More information

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate Environmental and Food Measurements Lab & Individual monitoring lab Yemen Republic Population : 22 million

More information

EVALUATION OF A NEUTRON-PHOTON SHIELD FOR TRANSURANIC (TRU) WASTE CONTAINERS

EVALUATION OF A NEUTRON-PHOTON SHIELD FOR TRANSURANIC (TRU) WASTE CONTAINERS EVALUATION OF A NEUTRON-PHOTON SHIELD FOR TRANSURANIC (TRU) WASTE CONTAINERS M. Gallegos, R. Ruby, E. J. Sullivan, R. J. Wishau Los Alamos National Laboratory ABSTRACT The Los Alamos National Laboratory

More information

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP Saudi Arabia : info_ksa@magusintl.com U.A.E : info_uae@magusintl.com Detecting Radiation Animations in this training work best in Windows XP February 2006 Why Detect Radiation Today? Medicine Imaging Cancer

More information

VERIFICATION OF IONISING RADIATION MONITORS FOR PRACTICAL USE IN HOSPITALS. C. Montes, F. Sáez, C. Martín, P. Collado, C. J. Sanz, E.

VERIFICATION OF IONISING RADIATION MONITORS FOR PRACTICAL USE IN HOSPITALS. C. Montes, F. Sáez, C. Martín, P. Collado, C. J. Sanz, E. VERIFICATION OF IONISING RADIATION MONITORS FOR PRACTICAL USE IN HOSPITALS C. Montes, F. Sáez, C. Martín, P. Collado, C. J. Sanz, E. De Sena Servicio de Radiofísica y Protección Radiológica. Hospital Universitario

More information

Any scenario. Maximum protection.

Any scenario. Maximum protection. Thermo Scientific Radiation Detection Solutions for Safety and Security Thermo Scientific RADSafe Certified Services Configurable services tailored to your specific needs Select from a wide variety of

More information

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY Seville, 31.03.2016 Pedro Martin, RadLab Radiation Facility Supervisor TÜV NORD GROUP QUALITY ASSURANCE AND SAFETY «Anything that can go

More information

Dual-Diode Dosimeter Patient Dose Monitor

Dual-Diode Dosimeter Patient Dose Monitor 37-720 Dual-Diode Dosimeter Patient Dose Monitor User Manual January 2008 Manual No. 160111 Rev. 6 2003, 2005, 2008 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks

More information

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY S E C T I O N 10 C O N T E N T S N A V I G A T I O N Introduction.................... 10.2 Portable Meters................. 10.3 Transmitter..................... 10.9 Probes......................... 10.10

More information

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific Thermo Scientific Heratherm Microbiological Incubators safe easy efficient Part of Thermo Fisher Scientific Thermo Scientific Heratherm Microbiological Incubators your samples We are obsessed with sample

More information

Radiation Safety and Equipment Considerations. Bonnie Meilner Regional Sales Manager LAURUS Systems Inc.

Radiation Safety and Equipment Considerations. Bonnie Meilner Regional Sales Manager LAURUS Systems Inc. Radiation Safety and Equipment Considerations Bonnie Meilner Regional Sales Manager LAURUS Systems Inc. bonnie.meilner@laurussystems.com COPYRIGHT LAURUS SYSTEMS INC - 2013 Why do you need Radiation Detectors

More information

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017 MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER August 2017 MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER August 2017 ii STATEMENT OF WARRANTY Ludlum Measurements, Inc. warrants the products covered

More information

Radiation Monitoring System RMS

Radiation Monitoring System RMS Radiation Monitoring System RMS VF RMS radiation monitoring system is a modular and standardized system for the radiological monitoring. Variety of radiation monitors, display and alarm units can be connected

More information

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science...

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science... XRD-1500 XRD-1500 High-Temperature Oven Innovation in Material Science... New materials science calls for refined tools that enable X-ray research in well-defined environments and under controlled temperature

More information

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S) LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S) Ganibu Dambis 26, P.O.Box 33 Riga, LV-1005, LATVIA Tel. (+371)6738-3947 Fax:(+371)6738-2620 office@bsi.lv www.bsi.lv CONTENTS INTRODUCTION...

More information

Measuring Couch Motion Accuracy with X-ray Beam Fluence

Measuring Couch Motion Accuracy with X-ray Beam Fluence Measuring Couch Motion Accuracy with X-ray Beam Fluence Rudi Labarbe, M.S. and Brett Nelson, M.S. IBA Particle Therapy, Belgium and Logos Systems, Scotts Valley, CA Introduction The accuracy of radiosurgery

More information

Comprehensive applications of the gas flow proportional counters for Radiological Surveillance

Comprehensive applications of the gas flow proportional counters for Radiological Surveillance Comprehensive applications of the gas flow proportional counters for Radiological Surveillance D.A.R.Babu, Anand Raman, Ashokkumar P and D.N.Sharma Radiation Safety Systems Division, Bhabha Atomic Research

More information

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE LEARNING OBJECTIVES: 2.19.01 Describe the features and specifications for commonly used laboratory counters or scalers: a. Detector type b. Detector shielding c. Detector window d. Types of radiation detected

More information

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems 41 Accurate Condition Monitoring made Quick, Simple and Cost Effective The (IOS) is an innovative solution to the

More information

REPUBLIC OF NAMIBIA MINISTRY OF HEALTH AND SOCIAL SERVICES REPORT BY: MS VERA UUSHONA TITLE: INSPECTION OF CONVENTIONAL DIAGNOSTIC X-RAY FACILITIES

REPUBLIC OF NAMIBIA MINISTRY OF HEALTH AND SOCIAL SERVICES REPORT BY: MS VERA UUSHONA TITLE: INSPECTION OF CONVENTIONAL DIAGNOSTIC X-RAY FACILITIES REPUBLIC OF NAMIBIA MINISTRY OF HEALTH AND SOCIAL SERVICES REPORT BY: MS VERA UUSHONA TITLE: INSPECTION OF CONVENTIONAL DIAGNOSTIC X-RAY FACILITIES ABSTRACT TITLE: Inspection of conventional diagnostic

More information

Technical Manual Ionisation Chamber MUSIC80

Technical Manual Ionisation Chamber MUSIC80 Technical Manual Ionisation Chamber MUSIC80 Entwicklungsbüro Dr. R. Schneider Lärchenstraße 9 85640 Putzbrunn Tel: 089 608 533 71 Fax: 089 608 533 72 E-Mail: robert@schneider.net Entwicklungsbüro Andreas

More information

Portable Instruments For First Response & In-Situ Analysis of Radiation

Portable Instruments For First Response & In-Situ Analysis of Radiation WWW.NATS-USA.COM Portable Instruments For First Response & In-Situ Analysis of Radiation North American Technical Services Bridging Technology With Latest in Radiation Detection Systems & Solutions The

More information

AeroDR X30. Digital Mobile X-ray System

AeroDR X30. Digital Mobile X-ray System AeroDR X30 Digital Mobile X-ray System AERODR X30 2 SPEED UP YOUR WORKFLOW COMMUNICATION WITH THE HOSPITAL NETWORK IS COMPLETELY WIRELESS Not all X-ray exams can be performed in the X-ray room itself.

More information

Lead-Lined Cabinetry. 7 Vreeland Road, Florham Park, NJ or

Lead-Lined Cabinetry. 7 Vreeland Road, Florham Park, NJ or Lead-Lined Cabinetry 7 Vreeland Road, Florham Park, NJ 07932 201.825.9500 or 800.631.3826 www.capintec.com Lead-Lined Cabinetry Everything about Capintec s lead-lined cabinetry conveys quality. Attention

More information

AERIAL RADIATION DETECTORS

AERIAL RADIATION DETECTORS DRONE READY AERIAL RADIATION DETECTORS DroneSENSOR TM Series Model ~ DroneRAD-ST TM (Search Tool or Mapping) - Gamma Model ~ DroneRAD-P TM (Air Monitor& Plume Detector) Particulate Alpha, Beta, Gamma &

More information

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests INTERNATIONAL STANDARD ISO 3999 Second edition 2004-12-15 Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests Radioprotection Appareils pour

More information

Parker icount Oil Sampler (IOS)

Parker icount Oil Sampler (IOS) Parker icount Oil Sampler (IOS) Portable condition monitoring for hydraulic oil and fuel systems Accurate condition monitoring made quick, simple and cost effective The icountos (IOS) is an innovative

More information

50(394) IEC. ore content meter ore sorting equipment overvoltage (of a Geiger-Müller county tube)...

50(394) IEC. ore content meter ore sorting equipment overvoltage (of a Geiger-Müller county tube)... INDEX A (absorbed) dose ratemeter... 394-11-17 absorption band (of a scintillator)... 394-18-08 acceptance test... 394-20-09 accident monitor... 394-12-27 activator... 394-10-08 actuated equipment... 394-14-05

More information

The Professional Choice

The Professional Choice The Professional Choice Product Catalogue Innovation in line with your clinical requirements How do you prepare for situations that leave no room for compromise? How do you get ready for an operation

More information

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR FEATURES: WORLD S ONLY PAG-LEVEL WATER MONITOR MEASURES AT OR BELOW EPA/DHS PAG LEVELS Protective Action Guideline Levels and Military Drinking Water Limits REAL TIME, IN-LINE, CONTINUOUS DETECTS ALPHAS,

More information

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009 RAM GENE-1 ERK MK-Ι & MK-ΙΙ Contamination & Radiation Meter Operating Manual Document #PRIR90N2.DOC Version 2.2 October 2009 Version / Revision Log: RAM GENE-1 ERK/ Operating Manual Ver./Rev.# Date Revised

More information

Safety vacuum drying oven for flammable solvents

Safety vacuum drying oven for flammable solvents VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with

More information

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient Microbiological Incubators safe easy efficient Microbiological Incubators your samples We are obsessed with sample integrity. Each of our new microbiological incubators is designed with sample protection

More information

PRD Domestic Price List

PRD Domestic Price List 901 nukalert Keychain Upper Limit Radiation Detector $150.00 907 palmrad Alpha, Beta, Gamma and X Ray Meter w/ 3 second update $760.00 P/N 6941 palmgraph windows software for Model 907 $110.00 P/N 6947

More information

22 Radiological and Environmental Monitoring Systems Functions, Basic Configuration, and Interfaces

22 Radiological and Environmental Monitoring Systems Functions, Basic Configuration, and Interfaces 22 Radiological and Environmental Monitoring Systems 22.1 Functions, Basic Configuration, and Interfaces 22.1.1 Functions 22.1.1.1 Radiological Monitoring and Protection System The primary function performed

More information

North American Technical Services

North American Technical Services WWW.NATS-USA.COM High Resolution Detectors (HPGE) North American Technical Services Bridging Technology Innovative Solutions In in Radiation Detection and & Analysis High Resolution Germanium Detectors

More information

RaySafe Xi Classic. A complete system for X-ray measurements

RaySafe Xi Classic. A complete system for X-ray measurements Classic A complete system for X-ray measurements Meet the family! The Classic is a complete system for multiparameter measurements on all X-ray modalities. It simultaneously measures everything from kvp

More information

Ronan Model X96S Series Weighing System

Ronan Model X96S Series Weighing System Ronan Model X96S Series Weighing System For more than 27 years Ronan has provided the process control industry with unsurpassed products in the harshest environments. With a philosophy of designing new

More information

Using the Model 1500 Portable Chilled Mirror Hygrometer

Using the Model 1500 Portable Chilled Mirror Hygrometer APPLICATION NOTE 2016_0120 MODEL 1500 Rev C Using the Model 1500 Portable Chilled Mirror Hygrometer The Model 1500 is a portable, multi-function, optical chilled mirror hygrometer designed to accurately

More information

LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR. February 2010 Serial Number PR and Succeeding Serial Numbers

LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR. February 2010 Serial Number PR and Succeeding Serial Numbers LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR February 2010 Serial Number PR090405 and Succeeding Serial Numbers LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR February 2010 Serial Number PR090405 and

More information

ALPHA Radiation Safety Manual

ALPHA Radiation Safety Manual ALPHA Radiation Safety Manual CONTACT INFORMATION In order to request radiation safety assistance or service during normal hours contact: IUB Radiation Safety Officer. 855-3230 Assistant Radiation Safety

More information

Installation, Operation & Maintenance Instructions Annealing Ovens TLD models

Installation, Operation & Maintenance Instructions Annealing Ovens TLD models Installation, Operation & Maintenance Instructions Annealing Ovens TLD models This manual is for the guidance of operators of the above Carbolite products and should be read before the oven is connected

More information

Electronic Personal Dosemeter

Electronic Personal Dosemeter Electronic Personal Dosemeter Tomoya Nunomia Hideshi Yamauchi Tetsuo Shibata 1. Introduction Since developing an electronic personal dosemeter that uses a semiconductor detector in 1983, Fuji Electric

More information

910A DOSIMETER CHARGER, AC-POWERED

910A DOSIMETER CHARGER, AC-POWERED DOSMETERS, MONTORS & METERS DRECT READNG DOSMETER 909B DOSMETER CHARGER 343-750 ELECTRONC POCKET DOSMETER Model 23, mrem and Model 23-1, msv Range 343-490 Direct Reading Dosimeter 0-200 mr 343-495 Direct

More information

Variable Temperature Microprobe Systems

Variable Temperature Microprobe Systems Variable Temperature Microprobe Systems the world s resource for variable temperature solid state characterization 2 The Variable Temperature Microprobe System The variable temperature microprobe system

More information

More Precision. Innovative Sensor Technologies. Displacement Distance Position. Dimension Temperature Colour

More Precision. Innovative Sensor Technologies. Displacement Distance Position. Dimension Temperature Colour More Precision Innovative Sensor Technologies Displacement Distance Position Dimension Temperature Colour Optical Sensors and Systems optoncdt - Laser triangulation displacement sensors Worldwide largest

More information

DIGITAL AREA RADIATION MONITOR

DIGITAL AREA RADIATION MONITOR RADIATION DETECTION AND MONITORS 103 AREAEXPERT DIGITAL AREA RADIATION MONITOR Touch screen LCD Colorful visual and audio indications Network compatible with CenterExpert software PC controllable Easily

More information

RAM GENE / RAM GENE-1

RAM GENE / RAM GENE-1 RAM GENE / RAM GENE-1 Radiation Meters Operating Manual Document #PRIR69N0.DOC Version 6.1 - December 2000 ROTEM INDUSTRIES LTD. ROTEM Industrial Park P.O.Box 9046, Beer-Sheva 84190, ISRAEL Tel: 972-8-6571312/6568652

More information

DEKO 25 washer-disinfector

DEKO 25 washer-disinfector DEKO 25 washer-disinfector DEKO 25 The DEKO 25 has been designed to bring reliability, outstanding cleaning and disinfection performance and quality into one compact and economic washer-disinfector. It

More information

Environmental Radiation Monitoring System

Environmental Radiation Monitoring System Environmental Radiation Monitoring System Toshihiro Takagi Osamu Kimura Atsushi Minagoshi 1. Introduction In order to ascertain conditions near the perimeter of a supervised area at a nuclear power plant

More information

The development of a plastic scintillator for radiotherapy dosimetry

The development of a plastic scintillator for radiotherapy dosimetry University of Wollongong Research Online University of Wollongong Thesis Collection 1954-2016 University of Wollongong Thesis Collections 2008 The development of a plastic scintillator for radiotherapy

More information

DOE 2.17 Contamination Monitoring Instrumentation Study Guide. 00ICP330 Rev. 0 Page 1 of 23

DOE 2.17 Contamination Monitoring Instrumentation Study Guide. 00ICP330 Rev. 0 Page 1 of 23 00ICP330 Rev. 0 Page 1 of 23 Course Title: Radiological Control Technician Module Title: Contamination Monitoring Instrumentation Module Number: 2.17 Objectives: 2.17.01 List the factors which affects

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection The Hart XL High Sensitivity Smoke Detection system (HSSD) is an aspirating fire detection system designed to give very early indication of an incipient fire condition.

More information

Datalogging as standard

Datalogging as standard Datalogging as standard for expanded performance Autofim II and Autofim II GC have a sophisticated datalogging system, as standard, which enables you to keep a permanent data record. The memory is capable

More information

LUDLUM MODEL AND LUDLUM MODEL ALPHA, BETA, & GAMMA DETECTORS

LUDLUM MODEL AND LUDLUM MODEL ALPHA, BETA, & GAMMA DETECTORS LUDLUM MODEL 44-9-18 AND LUDLUM MODEL 44-9-19 ALPHA, BETA, & GAMMA DETECTORS January 2018 Serial Number PR254331 and Succeeding Serial Numbers LUDLUM MODEL 44-9-18 AND LUDLUM MODEL 44-9-19 ALPHA, BETA,

More information

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science The world leader in serving science Instrumentation Post RDD Event Urban Reoccupancy James P. Menge PE Perception In the aftermath of a radiological emergency the public will see radiation and its potential

More information

DMC 2000 Personal Electronic Dosimeter

DMC 2000 Personal Electronic Dosimeter DMC 2000 Personal Electronic Dosimeter Accurate Dose And Dose Rate Measurement Pre-Set Audible And Visual Alarms Small Lightweight Design PROTECTION BEGINS WITH DETECTION The fi rst step in providing hazard

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection Hart XL High Sensitivity Smoke Detection (HSSD) TM is a smoke detection system that is simple to install, commission, service and use yet remains brilliantly capable in

More information

G-TECTA TM. Portable Gas Detection Instruments

G-TECTA TM. Portable Gas Detection Instruments G-TECTA TM Portable Gas Detection Instruments 2 Why Linde gas detection? The Linde Group is a global leader in the supply of gases, we provide expertise and product solutions to industry, commerce, science

More information

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION SEC SIGNATURE ETO MONITOR SIGETO1420597 PRODUCT INTRODUCED TO ETHYLENE OXIDE STERILIZATION INDUSTRY IN 2001. OVER 850 UNITS IN FIELD WORLDWIDE

More information