1 Operating instructions for HAWE devices For designated use in potentially explosive atmospheres B

2 by HAWE Hydraulik SE. The forwarding and reproduction of this document, as well as the use and communication of its contents, are forbidden unless expressely permitted. Any breach or infringement will result in liability for damages. All rights reserved concerning patent or utility model application. 2/7 B HAWE Hydraulik SE

3 Contents 1 General Identification Use Assembly, installation and disassembly Initial operation and settings Maintenance, service and troubleshooting Safety notes Tables: order coding, classification and usage Non-electrical part or purely mechanical component Displacement transducers Explosion protection explosive atmospheres of gas/air or dust/air mixtures, mists or vapours Explosion protection mining, mine gas and/or combustible dusts Single-action solenoid (for type BVG1, BVP1, NBVP16, G(1), NG(1), VP1, HSV21, SW2, SWP2, NSWP2) Explosion protection explosive atmospheres of gas/air or dust/air mixtures, mists or vapours Explosion protection mining, mine gas and/or combustible dusts Twin solenoid (for type PSL, PSV, PSM, PSLF, PSVF size 3, 5, 7, type PMZ 1) Explosion protection explosive atmospheres of gas/air or dust/air mixtures, mists or vapours Explosion protection mining, mine gas and/or combustible dusts Twin solenoid (for type PSL, PSV size 2, type PMZ 01) Explosion protection explosive atmospheres of gas/air or dust/air mixtures, mists or vapours Explosion protection mining, mine gas and/or combustible dusts...15 HAWE Hydraulik SE B /7

4 1 General The uid product has been designed, manufactured and tested using harmonised standards and directives generally applicable in the European Union and left the plant in a safe and fault-free condition. To maintain this condition and ensure safe operation, operators must observe the information and warnings in this operating and maintenance manual. The uid-technical product must only be installed and integrated into a hydraulic system by a quali ed technician, who is familiar with and works the generally accepted engineering standards and the latest legal regulations and standards of explosion protection. Furthermore, the special features of the application and/or operation environment must be carefully assessed and taken into account. 2 Identification Name and address of manufacturer Headquarter HAWE Hydraulik SE Streitfeldstr. 25 D München PO Box D München Tel Fax: info@hawe.de Device type and manufacturing date: Reference number for technical documentation: see type plate on request 4/7 B HAWE Hydraulik SE

5 3 Use In the directive2014/34/ the uid product is assigned to equipment group II category 2 and category 3 or equipment group I category M2 and can be used in zones 1, 2, 21, 22 in accordance with 1999/92/EC or in zone M2. The equipment is intended for use in areas where there are explosive gas/air and/or dust/air mixtures, mists or vapours. In accordance with DIN EN and DIN EN the uid product is assigned to the type of protection "c" with a maximum surface of 120 C, or class T4. The standard DIN EN and corresponding parts of this series of standards apply for the solenoids. -compliant solenoids and displacement transducers may only be operated using product-speci c operating and maintenance manuals and in the permissible ambient range. Around the world, other certificates and unit approval tests are regionally required in addition to. For a rough map, see Chapter 2, "Identification". Note For a precise list of all order codings and the assigned classifications, see Chapter 8, "Tables: order coding, classification and usage". 4 Assembly, installation and disassembly The uid product is to be attached to a level mounting surface. Commercially available, -compliant (if applicable) connecting elements ( ttings, hoses, tubes, etc.) from reputable manufacturers should be used to integrate the product into the hydraulic system. The hydraulic system must be decommissioned and depressurised in line with regulations (particularly in the case of systems with hydraulic accumulators) before removing the product. In this regard, also see the notes in General operating manual for the assembly, initial operation and maintenance of hydraulic components and systems: B 5488 HAWE Hydraulik SE B /7

6 5 Initial operation and settings Operation of uid-technical products is only permissible if installed mounting regulations. The device must be separately connected to ground in case dangerous potential differences occur (e.g. with insulated mounting) and if it is not guaranteed that the uid-technical piping system will establish a reliable connection to those components that are connected to ground.the manufacturer will generally deliver the device with the settings applied. Alternatively, the customer can also apply or adjust these settings. In this case the customer must refer to the instructions provided in the valid documentation for the speci c device. In this regard, also see the notes in General operating manual for the assembly, initial operation and maintenance of hydraulic components and systems: B Maintenance, service and troubleshooting The uid-technical product requires almost no maintenance. All hydraulic connections must be checked regularly - at least once every year - for possible damages (visual check). In case of external leakage the system must be taken out of operation and repaired. The user has to make sure that possibly vaporized ingredients of the escaped pressure uid do not cause any danger when blended with surrounding explosion hazardous atmosphere. The use of re inhibiting uids or mechanical shielding is recommended in such cases. The surface of the device must be checked regularly - at least once every year - for dust deposits, which should then be cleaned off. The product-speci c technical documentation speci es any other necessary maintenance work required to ensure safe and stable operation of the device. It is assumed that the generally known and applicable recommendations for service and operation of hydraulic systems are complied with. In this regard, also see the notes in General operating manual for the assembly, initial operation and maintenance of hydraulic components and systems: B /7 B HAWE Hydraulik SE

7 7 Safety notes 7a) General In addition to the EC Directive 2014/34/ and the national transpositions (the Product Safety Act (Produktsicherheitsgesetz, ProdSG) in Germany), EC [Standards number/designation] ( operational directive) and its transpositions (in Germany the Industrial Safety Regulation (Betriebssicherheitsverordnung, BetrSichV)) apply in particular for operators. In case the uid-technical product shows any signs of a defect, malfunctioning or external damage (including corrosion), the device must be taken out of operation immediately. Any deposits on the surface of the device must be avoided and must not obstruct heat emission. It is the user s duty to ensure free and unhindered heat emission during operation. This means that the device must neither be covered or stored immediately adjacent to heat sources during operation. Care is to be given that the device is not subjected to direct sunlight during operation. Caution Danger of burning due to hot metal surfaces! Risk of minor injury. Wear gloves. Allow the device to cool down for at least 10 minutes before touching it. The type plate / type stamping must not be removed/painted over, to ensure legibility and retain -approval. Color coating without giving notice to the manufacturer is forbidden. All electrical lines must be xed and a min. bending radius of 110 mm must be maintained. 7b) Product-speci c Single pumps, cover plate versions and power packs: In accordance with DIN EN and DIN EN item 5.4, in terms of content, moving parts which are protected by being immersed in a uid are sufficiently protected against ignition from the atmosphere through the arrangement of a monitoring element (e.g. level gauge, level switch) that displays any non-permitted loss of protective uid (this means pumps are to be operated in an oil-submerged arrangement). Any non-permitted heating of the protective uid is to be monitored by a switch (DIN EN ) for further safety. Furthermore, for the self-installation of pumps in tank containers, an -compliant coupling must be used. Pressure switches and directional spool valves with contact switches: Pressure switches in accordance with D 5440 and directional spool valves with contact switches for switching position monitoring are simple electrical operating media in the sense of DIN EN , subchapter 5.7, which do not have to be provided with any special marking. They can be operated in potentially explosive atmospheres in an intrinsically safe circuit (with isolation switch amplifier) and are assigned to class T6 in Group II. We recommend devices from PEPPERL + FUCHS GmbH, Mannheim, Germany, or from BARTEC, Menden, Germany, as isolation switch ampli ers. Hydraulic accumulators: Hydraulic accumulators do not have a heating system. Their surface depends on the operation condition and the of the pressure uid. A re-check of the max. surface, based on the customer specifications for working conditions, will be undertaken by the manufacturer on the product and will be documented. Intrinsically save components: Components with a solenoid classification O I M2 Ex d ib I ful l this classification only if used in combination with a ib - power supply of category M2. Note The classification of the type of protection is only valid if it is not restricted through the use of the device with other components (e.g. on a hydraulic power pack or with integration into a complete system) and their lower classification. In this case, the lowest classification applies. If necessary, the operating and maintenance manual for the electromagnet and its classification must be observed. Failure to comply with these regulations will result in loss of warranty claims against HAWE Hydraulik. HAWE Hydraulik SE B /7

8 8 Tables: order coding, classification and usage 8.1 Non-electrical part or purely mechanical component -EX Classification / marking Certificate of unit approval Declaration Operating and maintenance manual(s) Permissible ambient Group II, category 2, 3: O II 2 GD c T4 On request B -20 C +40 C Group I, category M2: O I M2 c On request B -20 C +40 C 8.2 Displacement transducers Explosion protection explosive atmospheres of gas/air or dust/air mixtures, mists or vapours Classification / marking Certificate of unit approval Operating and maintenance manual(s) incl. declaration -EX (EX09) O I M2 Ex db I Mb O II 2 G Ex db IIB T4 Gb IBExU X B 10/ C C O II 2 D Ex tb IIIC IP6X T 135 C Db Ex d I Mb Ex d IIB T4 Gb IBE X Ex tb IIIC T135 C Db 8/8 B HAWE Hydraulik SE

9 8.2.2 Explosion protection mining, mine gas and/or combustible dusts Classification / marking Certificate of unit approval Operating and maintenance manual(s) incl. declaration -M2FP (EX09) O I M2 Ex db I Mb O II 2G Ex db IIB T4 Gb IBExU X B 10/ C +40 C O II 2D Ex tb IIIC IP6X T135 C Db Ex d I Mb Ex d IIB T4 Gb IBE X Ex tb IIIC T135 C Db ANZEx Australia ANZEx X ANZEx X -IS (EX16) O I M1 Ex ia I Ma O II 1G Ex ia IIC T6 Ga IBExU X B 31/ C +70 C O II 1D Ex ia IIIC T80 C Da Ex ia I Ma Ex ia IIC T6 Ga IBE X Ex ia IIIC T80 C Da HAWE Hydraulik SE B /9

10 8.3 Single-action solenoid (for type BVG1, BVP1, NBVP16, G(1), NG(1), VP1, HSV21, SW2, SWP2, NSWP2) Explosion protection explosive atmospheres of gas/air or dust/air mixtures, mists or vapours Classification / marking Certificate of unit approval Operating and maintenance manual(s) incl. declaration -EX (EX02) O II 2G Ex db IIB + H2 T4 Gb O II 2D Ex tb IIIC T135 C Db TÜV-A X B 03/ C C -EX 55 FM 1) (EX14) O II 2G Ex db IIB + H2 T4 Gb O II 2D Ex tb IIIC T135 C Db FM X B 24/ C C Ex db IIB T4 Gb Ex tb IIIC T135 C Db FMG X NEC 500, NEC 505, CEC USA and Canada NEC 500, CEC Annex J: XP, Class I, Div. 1, Grp C,D T4 NEC 500, CEC sect. 18: DIP, Class II, Div. 1, Grp E,F,G T4 DIP, Class III, Div. 1 & , C NEC 505: Class I, Zone I, AEx d IIB + H2 T4 NEC 506: Zone 21, AEx tb IIIC T 135 C CEC sect. 18: Class I, Zone 1, Ex d IIB + H2 T4 EAC including Russia Which classification is stamped? RU C-DE.GB08.B B 37/2016 1) Limiting for directional seated valves BVG, BVP size 1, NBVP 16 (versions with one solenoid), G size 1, VP 1: S1 (100% duty cycle) up to max. 50 C; 90% duty cycle at 50 to 55 C 10/10 B HAWE Hydraulik SE

11 8.3.2 Explosion protection mining, mine gas and/or combustible dusts Classification / marking Certificate of unit approval Operating and maintenance manual(s) incl. declaration -M2FP (EX13) ANZEx Australia ANZEx X ANZEx X B 23/ C +40 C HAWE Hydraulik SE B /11

12 8.4 Twin solenoid (for type PSL, PSV, PSM, PSLF, PSVF size 3, 5, 7, type PMZ 1) Explosion protection explosive atmospheres of gas/air or dust/air mixtures, mists or vapours Classification / marking Certificate of unit approval Manual(s) incl. declaration -EX/ -EX 4 -TEX/ -TEX 4 (EX01) O II 2 G Ex mb II 120 C (T4) Gb O II 2 D Ex mb IIIC T120 C Db TÜV-A X B 01/ C C -TEX 55 -TEX 4 55 (EX08) O II 2 G Ex db IIB T4 Gb O II 2 D Ex tb IIIC T135 C Db Ex d IIB T4 Gb Ex tb IIIC T135 C Db IBExU X IBE X B 19/ C C -TEX 70 (EX06) O II 2 G Ex db IIB T4 Gb O II 2 D Ex tb IIIC T135 C Db IBExU X B 09/ C C Ex d IIB T4 Gb Ex tb IIIC T135 C Db IBE X -TEX 4 55 FM (EX11) O II 2G Ex db IIB T4 Gb O II 2D Ex tb IIIC T135 C Db FMG X B 22/ C C Ex db IIB T4 Gb Ex tb IIIC T135 C Db FMG X NEC 500, NEC 505, CEC USA, Canada NEC 500, CEC Annex J: XP, Class I, Div. 1, Grp C, D T4 NEC 500, CEC sect. 18: , C DIP, Class II, Div. 1, Grp E, F, G T4 DIP, Class III, Div. 1 & 2 NEC 505: Class I, Zone I, AEx d IIB T4 NEC 506: Zone 21, AEx tb T135 C 12/12 B HAWE Hydraulik SE

13 -TEX 70 FM (EX12) Classification / marking Certificate of unit approval Manual(s) incl. declaration CEC sect. 18: Class I, Zone 1, Ex d IIB T4 EAC Ex d IIB T4 Gb X TC RU C-DE.GB08.B B 35/2016 including Russia Ex tb IIIC T135 C Db X NEC 500, NEC 505, CEC USA, Canada O II 2G Ex db IIB T4 Gb O II 2D Ex tb IIIC T135 C Db Ex db IIB T4 Gb Ex tb IIIC T135 C Db NEC 500, CEC Annex J: XP, Class I, Div. 1, Grp C, D T4 NEC 500, CEC sect. 18: DIP, Class II, Div. 1, Grp E, F, G T4 DIP, Class III, Div. 1 & 2 NEC 505: Class I, Zone I, AEx d IIB T4 NEC 506: Zone 21, AEx tb T 135 C CEC sect. 18: Class I, Zone 1, Ex d IIB T4 FMG X FMG X , C B 21/2011 EAC Ex d IIB T4 Gb X RU GDE.GB08.B B 36/2016 including Russia Ex tb IIIC T135 C Db X -40 C +70 C HAWE Hydraulik SE B /13

14 8.4.2 Explosion protection mining, mine gas and/or combustible dusts Classification Certificate of unit approval Manual(s) incl. declaration -MSHA (EX05) O I M2 Ex db I Mb IBExU X B 04/ C +40 C Ex d I Mb IBE X MSHA USA 30CFR Part 18 Cert. No. 18-NXA NXA MA China J J M2FP (EX05) O I M2 Ex db I Mb IBExU X B 04/ C +40 C Ex d I Mb IBE X ANZEx Australia ANZEx X ANZEx X MA China J J IS (EX05-12VDC) O I M2 Ex db ib I Mb IBExU X B 17/ C +40 C Ex d ib I Mb IBE X MA China J J EAC including Russia Ex d ib I Mb X TC RU C-DE.GB08.B B 30/ /14 B HAWE Hydraulik SE

15 8.5 Twin solenoid (for type PSL, PSV size 2, type PMZ 01) Explosion protection explosive atmospheres of gas/air or dust/air mixtures, mists or vapours Classification Certificate of unit approval Manual(s) incl. declaration -TEX 4 55 FM (EX04) O II 2G Ex db IIB T4 Gb O II 2D Ex tb IIIC T135 C Db FM X B 28/ C C Ex db IIB T4 Gb Ex tb IIIC T135 C Db FMG X NEC 500, NEC 505, CEC USA, Canada NEC 500, CEC Annex J: XP, Class I, Div. 1, Grp C, D T4 NEC 500, CEC sect. 18: , C DIP, Class II, Div. 1, Grp E, F, G T4 DIP, Class III, Div. 1 & 2 NEC 505: Class I, Zone I, AEx d IIB T4 Gb NEC 506: Zone 21, AEx tb IIIC T 135 C Db CEC sect. 18: Class I, Zone 1, Ex d IIB T4 Gb Zone 21, Ex tb IIIC T135 C Db Explosion protection mining, mine gas and/or combustible dusts Classification Certificate of unit approval Manual(s) incl. declaration...-m2fp (EX03) O I M2 Ex db I Mb IBExU X B 25/ C +40 C Ex d I Mb IBE X HAWE Hydraulik SE B /15

16 Further information HAWE Hydraulik SE is a responsible development partner with application expertise and experience in more than 70 areas of mechanical engineering and plant engineering. The product range includes hydraulic power packs, constant and variable pumps, valves, sensors and accessories. The modular system is complemented by electronic components which are perfectly coordinated with the hydraulic components and simplify control, signal evaluation and fault detection. The intelligent system solutions reduce energy consumption and operating costs. Compact drives save space and permit innovative machine design. Approximately 2000 employees in 16 countries and more than 30 sales partners around the globe provide customers with local, professional and personal support. The company is certi ed in accordance with ISO 9001, ISO 14001, ISO 50001, OHSAS You can nd further information on HAWE Hydraulik, your local contact and the range of hydraulics training sessions offered at: B HAWE Hydraulik SE Streitfeldstraße München Postfach München Germany Tel Fax info@hawe.de

OPTIBAR P 1010/2010 C Supplementary instructions

OPTIBAR P 1010/2010 C Supplementary instructions OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

UL HAZARDOUS LOCATIONS SERVICES

UL HAZARDOUS LOCATIONS SERVICES UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,

More information

EtherCAT Box Modules (EPxxxx-xxxx)

EtherCAT Box Modules (EPxxxx-xxxx) Notes about operation of EtherCAT Box Modules (EPxxxx-xxxx) in potentially explosive areas (ATEX) Version: 1.1.0 Date: 2011-06-10 Table of Contents Table of Contents 1 Foreword 1 1.1 Notes on the documentation

More information

TRASCO ATEX Couplings

TRASCO ATEX Couplings TRASCO ATEX Couplings ATEX ANNEX GRM-CERT-EX-EN SIT S.p.A. Viale A. Volta, 2-20090 Cusago (MI) - Italy Tel. +39.02891441 Fax +39.0289144291 - info@sitspa.it www.sitspa.it ATEX Annex This Annex is an integral

More information

official distributor of Newson Gale Ltd.

official distributor of Newson Gale Ltd. Continuous Ground Loop Monitoring with visual indication. The precision and reliability of the provides enhanced safety and security by continuously testing the connection of the clamp to the container

More information

Both enclosures provide an IP 66 degree of ingress protection and are suitable for both indoor and outdoor installation.

Both enclosures provide an IP 66 degree of ingress protection and are suitable for both indoor and outdoor installation. Continuous Ground Loop Monitoring with visual indication. The precision and reliability of the provides enhanced safety and security by continuously testing the connection of the clamp to the container

More information

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories Hazardous Locations: Understanding the Basics of Global Compliance Requirements Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories DISCLAIMER/ TERMS OF USE: THE INFORMATION

More information

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition proof assemblies, where,

More information

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or

More information

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors Drive Technology \ Drive Automation \ System Integration \ Services *23511257_0817* Inquiry Forms for Explosion-Proof Gearmotors Edition 08/2017 23511257/EN SEW-EURODRIVE Driving the world Inquiry forms

More information

ANNEX GD-CERT-EX-EN SIT

ANNEX GD-CERT-EX-EN SIT SITEX ATEX Couplings ATEX ANNEX GD-CERT-EX-EN SIT S.p.A. Viale A. Volta, 2-20090 Cusago (MI) - Italy Tel. +39.02891441 Fax +39.0289144291 - info@sitspa.it www.sitspa.com ATEX Annex This Annex is an integral

More information

MANUAL Oil Level Sensor

MANUAL Oil Level Sensor PROCESS AUTOMATION MANUAL Oil Level Sensor KVF-104-PF ISO9001 0102 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products

More information

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas

More information

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0 Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:

More information

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0. Selection of Explosion Protected Equipment for Hazardous Locations Compiled by: Pieter Coetzee ZONE 2 ZONE 0 ZONE 1 Be safe be Ex Contents Introduction Occupational Health and Safety Act. (Act 85 of 1993)

More information

Guide for hazardous areas

Guide for hazardous areas Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection

More information

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS PENTAIR CLEAN AIR SYSTEMS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition

More information

Guide to Hazardous Location Approvals:

Guide to Hazardous Location Approvals: Selection Guide Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches Introduction There are many considerations when selecting a switch to be used in hazardous areas. In addition

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches A Selection Guide Introduction There are many considerations when selecting a switch to be used in hazardous areas. In

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...

More information

METALDRIVE ATEX Couplings

METALDRIVE ATEX Couplings METALDRIVE ATEX Couplings ANNEX ATEX GMD-CERT-EX-EN SIT S.p.A. Viale A. Volta, 2-20090 Cusago (MI) - Italy Tel. +39.02891441 Fax +39.0289144293 - export@sitspa.it www.sitspa.com ATEX Annex This Annex is

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element

More information

Certified drive and control products for explosion protection

Certified drive and control products for explosion protection Certified drive and control products for explosion protection 2 Occupational health and safety: Standards-compliant explosion protection Gases, steam, solvent mist, or dust: Whenever technical operating

More information

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The entrepreneurial basis of the R. STAHL Technology Group follows a long tradition. The product range is aimed at specialised

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC PROCESS AUTOMATION Instruction manual Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC With regard to the supply of products, the current issue of the following document is applicable: The General

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2557738 Master Contract: 256526 Issued to: Bartec Varnost d.o.o Cesta 9 avgusta 59 Zagorje ob Savi, 1410 Slovenia Attention: Janez Gajski The products listed below

More information

Magnetostrictive sensor For bypass level indicators Model BLM

Magnetostrictive sensor For bypass level indicators Model BLM Level Magnetostrictive sensor For bypass level indicators Model BLM KSR data sheet LM 10.05 for further approvals see page 2 and 3 Applications Sensor for the continuous level measurement of liquids in

More information

Guide to Intrinsically Safe Portable Radios

Guide to Intrinsically Safe Portable Radios Guide to Intrinsically Safe Portable Radios An overview of common IS standards www.taitradio.com GUIDE TO INTRINSICALLY SAFE PORTABLE RADIOS SUMMARY The development of equipment for explosive atmospheres

More information

Overview of Hazardous Locations as They Relate to Solenoid Valves

Overview of Hazardous Locations as They Relate to Solenoid Valves Overview of Hazardous Locations as They Relate to Solenoid Valves Defined: Hazardous Location - "where fire or explosion hazards may exist due to flammable gases or vapors, flammable liquids, combustible

More information

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O****** Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O****** CSA 14.2662675 Ex ia IIC T6 Ga, Gb 0044 Document ID: 48924 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush

More information

OPTIWAVE X500 Supplementary Instructions

OPTIWAVE X500 Supplementary Instructions OPTIWAVE X500 Supplementary Instructions OPTIWAVE 3500 C OPTIWAVE 6500 C OPTIWAVE 7500 C Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE X500 1 General safety information 4 1.1

More information

EU DECLARATION OF CONFORMITY

EU DECLARATION OF CONFORMITY The Low Voltage Directive (LVD) 2014/35/EU and Electromagnetic Compatibility (EMC) Directive 2014/30/EU. Capacitive level sensor DLS 27N(T) Capacitive level sensor type DLS 27N(T) is designed to bistable

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm

More information

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems IRCO2 IRHC Operating and Installation Instructions Gas Detection and Warning Systems Important Instructions Prerequisites for safe and reliable operation of the system: Appropriate transport and handling

More information

ATEX, NOMENCLATURE AND CODING

ATEX, NOMENCLATURE AND CODING ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are ATEX, as well as

More information

Indoor/outdoor resistance thermometer Model TR60

Indoor/outdoor resistance thermometer Model TR60 Temperature Indoor/outdoor resistance thermometer Model TR60 WIKA data sheet TE 60.60 for further approvals see page 2 Applications Ambient temperature measurement Air-conditioned rooms, cold-storage rooms,

More information

ATEX, NOMENCLATURE AND CODING

ATEX, NOMENCLATURE AND CODING Technical Notes ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are

More information

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO PROZESSAUTOMATION Manual SEGMENT PROTECTOR R-SP-!12 FieldConnex TM Segment Protectors with overloaod protection and short-circuit current limitation for the connection of 12 field devices Zone 1 Zone 2

More information

Dual certification! Air handling units for potentially explosive atmospheres

Dual certification! Air handling units for potentially explosive atmospheres Dual certification! Air handling units for potentially explosive atmospheres X-CUBE Ex A certified safety product The air handling unit with dual ATEX certification ATEX directive 2014/34/EU applies to

More information

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Rosemount 752 FOUNDATION Fieldbus Remote Indicator Rosemount 752 FOUNDATION Fieldbus Remote Indicator Product Data Sheet 00813-0100-4377, Rev FA Two-wire segment powered device Displays up to eight values Link Master Capability Optional PID, Characterizer,

More information

VERSAFLOW VORTEX Supplementary instructions

VERSAFLOW VORTEX Supplementary instructions VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according

More information

ATM Lighting sp. z o.o

ATM Lighting sp. z o.o INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL390LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,

More information

manual addendum DELPHI Ex

manual addendum DELPHI Ex manual addendum DELPHI Ex II 2G Ex eb IIC T4 Gb II 2D Ex tb IIIC T135 C IP65 Db Tamb=-20 +40 C Reference list: Norm (last issue) Title Dir. 2014/34/UE EN 60079-31 EN60079-0 EN60079-7 Equipment and Protective

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

Smart encoders & actuators

Smart encoders & actuators Declaration of Conformity The manufacturer: LIKA ELECTRONIC SRL 36010 Carrè (VI) - Italy hereby declares that the following products (only when correctly assembled): XAC8018/1PB-14 XAC8018/1CB-14 XAC8018/1FD-14

More information

Manual Isolating Barrier D461 (Revision 05)

Manual Isolating Barrier D461 (Revision 05) D461 Manual Isolating Barrier D461 (Revision 05) Product Manual Original Instructions valid for models D461.11 with 1x signal input into 1x isolated signal output D461.12 with 1x signal input into 2x isolated

More information

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 4.1 Electrical limit switch... 4

More information

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting systems. Our main objective is to offer high

More information

Safety instructions VEGAPULS 64

Safety instructions VEGAPULS 64 Safety instructions Intrinsic safety "i" 4 20 ma/hart - two-wire Document ID: 53001 Contents 1 Area of applicability... 3 2 Important specification in the type code... 3 3 Different ignition protection

More information

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC Quick Introduction to TÛV Denmark TÜV Denmark - is a part of the TÜV NORD Group a global Organisation f Certification and Inspection of: Quality Management Systems, Products, Processes and Qualification

More information

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D Regulated Ex-Heater HEX5-1.08 with internal controller, HEX5-2.08 with external controller II 3 G II 3 D Instruction Manual Version 1.02.00 Dear customer, we have made up this operating manual in such

More information

Quick Start Guide For the

Quick Start Guide For the A Leader in Level Measurement Quick Start Guide For the Universal IV Lite and Universal IV Pro Model Transmitters 2-Wire RF Admittance / Capacitance Level Measurement System with HART Protocol For Assistance

More information

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans Operating Instructions Edition 11/2005 Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA sitrans Introduction 1 General safety instructions 2 SITRANS Process monitoring Ex-barrier

More information

MANUAL Overflow sensor NVF-104/34-PF

MANUAL Overflow sensor NVF-104/34-PF PROCESS AUTOMATION MANUAL Overflow sensor NVF-104/34-PF ISO9001 0102 Overflow sensor NVF-104/34-PF With regard to the supply of products, the current issue of the following document is applicable: The

More information

Intrinsically safe acoustic emission equipment opens the door to permanent monitoring applications in the oil and gas industry

Intrinsically safe acoustic emission equipment opens the door to permanent monitoring applications in the oil and gas industry 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Intrinsically safe acoustic emission equipment opens the door to permanent monitoring applications in the oil and

More information

Temperature Measurement Transmitters for field mounting

Temperature Measurement Transmitters for field mounting Siemens AG 07 Overview Application The SITRANS TF can be used everywhere where temperatures need to be measured under particularly harsh conditions. For that reasons users from all industries have opted

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

ATM Lighting sp. z o.o

ATM Lighting sp. z o.o INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL210LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,

More information

Beamex Calibration White Paper. Calibration in hazardous areas

Beamex Calibration White Paper.  Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

INTRINSICALLY SAFE LIGHTING RANGE

INTRINSICALLY SAFE LIGHTING RANGE Trusted worldwide since 1989 INTRINSICALLY SAFE LIGHTING RANGE SAFE PORTABLE RECHARGEABLE AC MAINS Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting

More information

Manual. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations. Version 1.0.

Manual. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations. Version 1.0. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations 2 General WAGO-I/O-SYSTEM 750 General 2010 by WAGO Kontakttechnik GmbH & Co. KG All rights

More information

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU GENERAL The accidental ignition of an atmosphere containing a large quantity of gas, vapour, mists and/or dust may cause an explosion. Specific

More information

Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust

Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust Competence for Safety Within the scope of the creation of the explosion protection document (mandatory for the operator according to ATEX 137), production locations must be divided into zones depending

More information

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017 Rosemount 214C Sensor 00825-0400-2654, Rev AF NOTICE This guide provides basic guidelines for Rosemount 214C Sensor models. If the sensor was ordered assembled to a temperature thermowell or transmitter,

More information

Certification Supplement Manual

Certification Supplement Manual SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 5 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EU DECLARATION OF CONFORMITY 3 EUROPEAN

More information

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE PUE HX5.EX explosion-proof hazardous area indicator ATEX APPROVAL PUE HX5.EX is a cutting-edge weighing indicator, designed to

More information

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt Airo Wireless Intrinsically Safe White Paper Written By: David Schmitt Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection certification for safe operation with electronic

More information

HAUBER-Elektronik. Product overview. Condition monitoring Mechanical protection in compliance with DIN ISO 10816

HAUBER-Elektronik. Product overview. Condition monitoring Mechanical protection in compliance with DIN ISO 10816 HAUBER-Elektronik Product overview Condition monitoring Mechanical protection in compliance with DIN ISO 10816 History 01/07/1966 Foundation 01/07/1966 - Foundation of the company in the HAUBER bakery

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation non-flush Assured operating distance s a 0...

More information

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard Persons concerned: Experienced professional electricians as per EU Directive

More information

Beamex. Calibration White Paper. Calibration in hazardous areas

Beamex. Calibration White Paper.   Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

MICROpeL 75 Combustible Gas Sensor Part Number: PM

MICROpeL 75 Combustible Gas Sensor Part Number: PM MICROpeL 75 Combustible Gas Sensor Part Number: PM759-000 Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance Reduced

More information

AD.3.XG... Atex directive ch. I Page 22 Atex classification ch. I Page 23. Tab.1 Assembly ch. I Page 25

AD.3.XG... Atex directive ch. I Page 22 Atex classification ch. I Page 23. Tab.1 Assembly ch. I Page 25 Atex directive ch. I Page 22 Atex classification ch. I Page 23 Series ch. I Page 24 Technical specifications Ch. I Page 24 Ordering code ch. I Page 24 Tab. Assembly ch. I Page 25 Tab. 2 Voltages ch. I

More information

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres Z31.0.XX.6C-11 Temperature Probe for potentially explosive atmospheres (Measuring ranges from -200 to +900 C) Operating Manual GTF 103-Ex 0081 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße

More information

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here. A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here Introduction Potentially Explosive Atmospheres exist where there is a risk

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance

More information

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2017 Shanghai, China Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2017 Peter Thurnherr Shanghai thuba Electric Co. Ltd.,

More information

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description

More information

Dräger X-am 5000 Multi-Gas Detection

Dräger X-am 5000 Multi-Gas Detection Dräger X-am 5000 Multi-Gas Detection The Dräger X-am 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures

More information

Quick Start Guide , Rev DA December Rosemount Volume 1 Sensor Assembly

Quick Start Guide , Rev DA December Rosemount Volume 1 Sensor Assembly Quick Start Guide 00825-0300-2654, Rev DA Rosemount Volume 1 Sensor Assembly Quick Start Guide NOTICE This guide provides basic guidelines for Rosemount 0068, 0078, and 0183 Sensor models. It does not

More information

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING

More information

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further. ATEX SOLUTIONS In order to apply a single level for health and safety requirements and to overcome barriers of trade within Europe, national regulations for explosion prevention were harmonized in 1975

More information

S T R I T T & P R I E B E I N C.

S T R I T T & P R I E B E I N C. Equipment Enclosure Comparisons Type of Enclosure European - Area of use Designation Standard IEC - Area of use Designation Standard USA - Area of use Designation Standard Flameproof Enclosure An enclosure

More information

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor Product ID Type # Product # Drawing # DSF 1210.00 SHV Ex-atex (2m) 374Z-05066 110428F1 DSF 1210.00 SHV Ex-atex (5m) 374Z-05176 110428F1 DSF 1210.00 SHV Ex-atex (10m) 374Z-05590 110428F1 DSF 1410.00 SHV

More information

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly Quick Start Guide 00825-0200-2654, Rev EA Rosemount 0065/0185 Sensor Assembly Quick Start Guide NOTICE This guide provides basic guidelines for Rosemount 0065 and 0185 Sensor models. It does not provide

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

Operating Instructions

Operating Instructions Operating Instructions MSi-JM0100-USB R. STAHL HMI Systems GmbH Adolf-Grimme-Allee 8 D 50829 Köln Operating Instructions Version: 01.00.03 Issue date: 29.06.2017 Disclaimer Disclaimer Publisher and copyright

More information

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016 Rosemount 148 Temperature Transmitter 00825-0100-4148, Rev GA NOTICE This guide provides basic guidelines for the Rosemount 148. It does not provide instructions for detailed configuration, diagnostics,

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

ESSENTIAL EXPLOSION PROTECTION

ESSENTIAL EXPLOSION PROTECTION ESSENTIAL EXPLOSION PROTECTION 2 3 FOREWORD In many industries, gases, vapours, mist and dust develop and escape in the course of manufacturing, processing, transporting and storing combustible substances.

More information

AD.3.XG... DIRECTIONAL CONTROLE CETOP 3

AD.3.XG... DIRECTIONAL CONTROLE CETOP 3 AD.3.XG... ATEX DIRECTIVE CH. I PAGE 23 ATEX CLASSIFICATION CH. I PAGE 24 SERIES AD.3.XG... CH. I PAGE 25 TECHNICAL SPECIFICATIONS CH. I PAGE 25 ORDERING CODE CH. I PAGE 25 TAB. ASSEMBLY CH. I PAGE 26

More information

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals Selecting a Safe Tank Gauging Product Understanding Hazardous Area Definitions for Equipment Approvals Hazardous Area Approvals A Worldwide Requirement There are many environmental considerations within

More information

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Drive systems for the chemical, oil and gas industry. Electric drives and systems Drive systems for the chemical, oil and gas industry Electric drives and systems 2 VEM drive systems for the chemical, oil and gas industry VEM drive systems for the chemical, oil and gas industry 3 VEM

More information